#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:IN20:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:IN20:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:IN20:1:CTRL CA PP")
  field(LNK2, "MGNT:IN20:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:IN20:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:IN20:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:IN20:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:IN20:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:IN20:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:IN20:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:IN20:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:IN20:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:IN20:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:IN20:1:ALLSWITCH")
}

record(seq, "MGNT:IN20:1:ALLSWITCH") {
  field(DOL1, "MGNT:IN20:1:CTRL.FFVL")
  field(LNK1, "MGNT:IN20:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:IN20:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:IN20:1:CTRL")
}

record(bo, "MGNT:IN20:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:IN20:1:ALLSTARGO")
}

record(fanout, "MGNT:IN20:1:ALLSTARGO") {
  field(LNK1, "MGNT:IN20:1:ALLBENDSGO")
  field(LNK2, "MGNT:IN20:1:ALLBTRMSGO")
  field(LNK3, "MGNT:IN20:1:ALLLGPSSGO")
  field(LNK4, "MGNT:IN20:1:ALLQUADSGO")
  field(LNK5, "MGNT:IN20:1:ALLXCORSGO")
  field(LNK6, "MGNT:IN20:1:ALLYCORSGO")
  field(FLNK, "MGNT:IN20:1:ALLSTARGO_2")
}
record(fanout, "MGNT:IN20:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:IN20:1:ALLSOLNSGO")
  field(LNK2, "MGNT:IN20:1:ALLKICKSGO")
  field(LNK3, "MGNT:IN20:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:IN20:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:IN20:1:BENDSWITCH")
}

record(seq, "MGNT:IN20:1:BENDSWITCH") {
  field(DOL1, "MGNT:IN20:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:IN20:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:IN20:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:IN20:1:BENDCTRL")
}

record(seq, "MGNT:IN20:1:ALLBENDSGO") {
  field(DOL1, "MGNT:IN20:1:ALLSTAR")
  field(LNK1, "MGNT:IN20:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:IN20:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:IN20:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:IN20:1:BENDCTRL",20,10,0,0,"MGNT:IN20:1:BENDCTRL")
#! Field("MGNT:IN20:1:BENDCTRL.FLNK",16777215,1,"MGNT:IN20:1:BENDCTRL.FLNK")
#! Link("MGNT:IN20:1:BENDCTRL.FLNK","MGNT:IN20:1:BENDSWITCH")
#! Field("MGNT:IN20:1:BENDCTRL.FFVL",16777215,1,"MGNT:IN20:1:BENDCTRL.FFVL")
#! Record("MGNT:IN20:1:BENDSWITCH",460,322,0,0,"MGNT:IN20:1:BENDSWITCH")
#! Field("MGNT:IN20:1:BENDSWITCH.DOL1",16777215,0,"MGNT:IN20:1:BENDSWITCH.DOL1")
#! Link("MGNT:IN20:1:BENDSWITCH.DOL1","MGNT:IN20:1:BENDCTRL.FFVL")
#! Field("MGNT:IN20:1:BENDSWITCH.LNK1",16777215,1,"MGNT:IN20:1:BENDSWITCH.LNK1")
#! Field("MGNT:IN20:1:BENDSWITCH.FLNK",16777215,1,"MGNT:IN20:1:BENDSWITCH.FLNK")
#! Record("MGNT:IN20:1:ALLBENDSGO",240,96,0,0,"MGNT:IN20:1:ALLBENDSGO")
#! Field("MGNT:IN20:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:IN20:1:ALLBENDSGO.DOL1")
#! Field("MGNT:IN20:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:IN20:1:ALLBENDSGO.LNK1")
#! Link("MGNT:IN20:1:ALLBENDSGO.LNK1","MGNT:IN20:1:ALLBENDS.VAL")
#! Record("MGNT:IN20:1:ALLBENDS",540,102,0,0,"MGNT:IN20:1:ALLBENDS")
#! Field("MGNT:IN20:1:ALLBENDS.VAL",16777215,0,"MGNT:IN20:1:ALLBENDS.VAL")
#! Field("MGNT:IN20:1:ALLBENDS.FLNK",16777215,1,"MGNT:IN20:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:IN20:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:IN20:1:BTRMSWITCH")
}

record(seq, "MGNT:IN20:1:BTRMSWITCH") {
  field(DOL1, "MGNT:IN20:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:IN20:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:IN20:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:IN20:1:BTRMCTRL")
}

record(seq, "MGNT:IN20:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:IN20:1:ALLSTAR")
  field(LNK1, "MGNT:IN20:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:IN20:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:IN20:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:IN20:1:BTRMCTRL",20,10,0,0,"MGNT:IN20:1:BTRMCTRL")
#! Field("MGNT:IN20:1:BTRMCTRL.FLNK",16777215,1,"MGNT:IN20:1:BTRMCTRL.FLNK")
#! Link("MGNT:IN20:1:BTRMCTRL.FLNK","MGNT:IN20:1:BTRMSWITCH")
#! Field("MGNT:IN20:1:BTRMCTRL.FFVL",16777215,1,"MGNT:IN20:1:BTRMCTRL.FFVL")
#! Record("MGNT:IN20:1:BTRMSWITCH",460,322,0,0,"MGNT:IN20:1:BTRMSWITCH")
#! Field("MGNT:IN20:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:IN20:1:BTRMSWITCH.DOL1")
#! Link("MGNT:IN20:1:BTRMSWITCH.DOL1","MGNT:IN20:1:BTRMCTRL.FFVL")
#! Field("MGNT:IN20:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:IN20:1:BTRMSWITCH.LNK1")
#! Field("MGNT:IN20:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:IN20:1:BTRMSWITCH.FLNK")
#! Record("MGNT:IN20:1:ALLBTRMSGO",240,96,0,0,"MGNT:IN20:1:ALLBTRMSGO")
#! Field("MGNT:IN20:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:IN20:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:IN20:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:IN20:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:IN20:1:ALLBTRMSGO.LNK1","MGNT:IN20:1:ALLBTRMS.VAL")
#! Record("MGNT:IN20:1:ALLBTRMS",540,102,0,0,"MGNT:IN20:1:ALLBTRMS")
#! Field("MGNT:IN20:1:ALLBTRMS.VAL",16777215,0,"MGNT:IN20:1:ALLBTRMS.VAL")
#! Field("MGNT:IN20:1:ALLBTRMS.FLNK",16777215,1,"MGNT:IN20:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:IN20:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:IN20:1:LGPSSWITCH")
}

record(seq, "MGNT:IN20:1:LGPSSWITCH") {
  field(DOL1, "MGNT:IN20:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:IN20:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:IN20:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:IN20:1:LGPSCTRL")
}

record(seq, "MGNT:IN20:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:IN20:1:ALLSTAR")
  field(LNK1, "MGNT:IN20:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:IN20:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:IN20:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:IN20:1:LGPSCTRL",20,10,0,0,"MGNT:IN20:1:LGPSCTRL")
#! Field("MGNT:IN20:1:LGPSCTRL.FLNK",16777215,1,"MGNT:IN20:1:LGPSCTRL.FLNK")
#! Link("MGNT:IN20:1:LGPSCTRL.FLNK","MGNT:IN20:1:LGPSSWITCH")
#! Field("MGNT:IN20:1:LGPSCTRL.FFVL",16777215,1,"MGNT:IN20:1:LGPSCTRL.FFVL")
#! Record("MGNT:IN20:1:LGPSSWITCH",460,322,0,0,"MGNT:IN20:1:LGPSSWITCH")
#! Field("MGNT:IN20:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:IN20:1:LGPSSWITCH.DOL1")
#! Link("MGNT:IN20:1:LGPSSWITCH.DOL1","MGNT:IN20:1:LGPSCTRL.FFVL")
#! Field("MGNT:IN20:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:IN20:1:LGPSSWITCH.LNK1")
#! Field("MGNT:IN20:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:IN20:1:LGPSSWITCH.FLNK")
#! Record("MGNT:IN20:1:ALLLGPSSGO",240,96,0,0,"MGNT:IN20:1:ALLLGPSSGO")
#! Field("MGNT:IN20:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:IN20:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:IN20:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:IN20:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:IN20:1:ALLLGPSSGO.LNK1","MGNT:IN20:1:ALLLGPSS.VAL")
#! Record("MGNT:IN20:1:ALLLGPSS",540,102,0,0,"MGNT:IN20:1:ALLLGPSS")
#! Field("MGNT:IN20:1:ALLLGPSS.VAL",16777215,0,"MGNT:IN20:1:ALLLGPSS.VAL")
#! Field("MGNT:IN20:1:ALLLGPSS.FLNK",16777215,1,"MGNT:IN20:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:IN20:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:IN20:1:QUADSWITCH")
}

record(seq, "MGNT:IN20:1:QUADSWITCH") {
  field(DOL1, "MGNT:IN20:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:IN20:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:IN20:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:IN20:1:QUADCTRL")
}

record(seq, "MGNT:IN20:1:ALLQUADSGO") {
  field(DOL1, "MGNT:IN20:1:ALLSTAR")
  field(LNK1, "MGNT:IN20:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:IN20:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:IN20:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:IN20:1:QUADCTRL",20,10,0,0,"MGNT:IN20:1:QUADCTRL")
#! Field("MGNT:IN20:1:QUADCTRL.FLNK",16777215,1,"MGNT:IN20:1:QUADCTRL.FLNK")
#! Link("MGNT:IN20:1:QUADCTRL.FLNK","MGNT:IN20:1:QUADSWITCH")
#! Field("MGNT:IN20:1:QUADCTRL.FFVL",16777215,1,"MGNT:IN20:1:QUADCTRL.FFVL")
#! Record("MGNT:IN20:1:QUADSWITCH",460,322,0,0,"MGNT:IN20:1:QUADSWITCH")
#! Field("MGNT:IN20:1:QUADSWITCH.DOL1",16777215,0,"MGNT:IN20:1:QUADSWITCH.DOL1")
#! Link("MGNT:IN20:1:QUADSWITCH.DOL1","MGNT:IN20:1:QUADCTRL.FFVL")
#! Field("MGNT:IN20:1:QUADSWITCH.LNK1",16777215,1,"MGNT:IN20:1:QUADSWITCH.LNK1")
#! Field("MGNT:IN20:1:QUADSWITCH.FLNK",16777215,1,"MGNT:IN20:1:QUADSWITCH.FLNK")
#! Record("MGNT:IN20:1:ALLQUADSGO",240,96,0,0,"MGNT:IN20:1:ALLQUADSGO")
#! Field("MGNT:IN20:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:IN20:1:ALLQUADSGO.DOL1")
#! Field("MGNT:IN20:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:IN20:1:ALLQUADSGO.LNK1")
#! Link("MGNT:IN20:1:ALLQUADSGO.LNK1","MGNT:IN20:1:ALLQUADS.VAL")
#! Record("MGNT:IN20:1:ALLQUADS",540,102,0,0,"MGNT:IN20:1:ALLQUADS")
#! Field("MGNT:IN20:1:ALLQUADS.VAL",16777215,0,"MGNT:IN20:1:ALLQUADS.VAL")
#! Field("MGNT:IN20:1:ALLQUADS.FLNK",16777215,1,"MGNT:IN20:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:IN20:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:IN20:1:XCORSWITCH")
}

record(seq, "MGNT:IN20:1:XCORSWITCH") {
  field(DOL1, "MGNT:IN20:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:IN20:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:IN20:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:IN20:1:XCORCTRL")
}

record(seq, "MGNT:IN20:1:ALLXCORSGO") {
  field(DOL1, "MGNT:IN20:1:ALLSTAR")
  field(LNK1, "MGNT:IN20:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:IN20:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:IN20:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:IN20:1:XCORCTRL",20,10,0,0,"MGNT:IN20:1:XCORCTRL")
#! Field("MGNT:IN20:1:XCORCTRL.FLNK",16777215,1,"MGNT:IN20:1:XCORCTRL.FLNK")
#! Link("MGNT:IN20:1:XCORCTRL.FLNK","MGNT:IN20:1:XCORSWITCH")
#! Field("MGNT:IN20:1:XCORCTRL.FFVL",16777215,1,"MGNT:IN20:1:XCORCTRL.FFVL")
#! Record("MGNT:IN20:1:XCORSWITCH",460,322,0,0,"MGNT:IN20:1:XCORSWITCH")
#! Field("MGNT:IN20:1:XCORSWITCH.DOL1",16777215,0,"MGNT:IN20:1:XCORSWITCH.DOL1")
#! Link("MGNT:IN20:1:XCORSWITCH.DOL1","MGNT:IN20:1:XCORCTRL.FFVL")
#! Field("MGNT:IN20:1:XCORSWITCH.LNK1",16777215,1,"MGNT:IN20:1:XCORSWITCH.LNK1")
#! Field("MGNT:IN20:1:XCORSWITCH.FLNK",16777215,1,"MGNT:IN20:1:XCORSWITCH.FLNK")
#! Record("MGNT:IN20:1:ALLXCORSGO",240,96,0,0,"MGNT:IN20:1:ALLXCORSGO")
#! Field("MGNT:IN20:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:IN20:1:ALLXCORSGO.DOL1")
#! Field("MGNT:IN20:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:IN20:1:ALLXCORSGO.LNK1")
#! Link("MGNT:IN20:1:ALLXCORSGO.LNK1","MGNT:IN20:1:ALLXCORS.VAL")
#! Record("MGNT:IN20:1:ALLXCORS",540,102,0,0,"MGNT:IN20:1:ALLXCORS")
#! Field("MGNT:IN20:1:ALLXCORS.VAL",16777215,0,"MGNT:IN20:1:ALLXCORS.VAL")
#! Field("MGNT:IN20:1:ALLXCORS.FLNK",16777215,1,"MGNT:IN20:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:IN20:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:IN20:1:YCORSWITCH")
}

record(seq, "MGNT:IN20:1:YCORSWITCH") {
  field(DOL1, "MGNT:IN20:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:IN20:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:IN20:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:IN20:1:YCORCTRL")
}

record(seq, "MGNT:IN20:1:ALLYCORSGO") {
  field(DOL1, "MGNT:IN20:1:ALLSTAR")
  field(LNK1, "MGNT:IN20:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:IN20:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:IN20:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:IN20:1:YCORCTRL",20,10,0,0,"MGNT:IN20:1:YCORCTRL")
#! Field("MGNT:IN20:1:YCORCTRL.FLNK",16777215,1,"MGNT:IN20:1:YCORCTRL.FLNK")
#! Link("MGNT:IN20:1:YCORCTRL.FLNK","MGNT:IN20:1:YCORSWITCH")
#! Field("MGNT:IN20:1:YCORCTRL.FFVL",16777215,1,"MGNT:IN20:1:YCORCTRL.FFVL")
#! Record("MGNT:IN20:1:YCORSWITCH",460,322,0,0,"MGNT:IN20:1:YCORSWITCH")
#! Field("MGNT:IN20:1:YCORSWITCH.DOL1",16777215,0,"MGNT:IN20:1:YCORSWITCH.DOL1")
#! Link("MGNT:IN20:1:YCORSWITCH.DOL1","MGNT:IN20:1:YCORCTRL.FFVL")
#! Field("MGNT:IN20:1:YCORSWITCH.LNK1",16777215,1,"MGNT:IN20:1:YCORSWITCH.LNK1")
#! Field("MGNT:IN20:1:YCORSWITCH.FLNK",16777215,1,"MGNT:IN20:1:YCORSWITCH.FLNK")
#! Record("MGNT:IN20:1:ALLYCORSGO",240,96,0,0,"MGNT:IN20:1:ALLYCORSGO")
#! Field("MGNT:IN20:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:IN20:1:ALLYCORSGO.DOL1")
#! Field("MGNT:IN20:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:IN20:1:ALLYCORSGO.LNK1")
#! Link("MGNT:IN20:1:ALLYCORSGO.LNK1","MGNT:IN20:1:ALLYCORS.VAL")
#! Record("MGNT:IN20:1:ALLYCORS",540,102,0,0,"MGNT:IN20:1:ALLYCORS")
#! Field("MGNT:IN20:1:ALLYCORS.VAL",16777215,0,"MGNT:IN20:1:ALLYCORS.VAL")
#! Field("MGNT:IN20:1:ALLYCORS.FLNK",16777215,1,"MGNT:IN20:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:IN20:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:IN20:1:SOLNSWITCH")
}

record(seq, "MGNT:IN20:1:SOLNSWITCH") {
  field(DOL1, "MGNT:IN20:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:IN20:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:IN20:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:IN20:1:SOLNCTRL")
}

record(seq, "MGNT:IN20:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:IN20:1:ALLSTAR")
  field(LNK1, "MGNT:IN20:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:IN20:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:IN20:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:IN20:1:SOLNCTRL",20,10,0,0,"MGNT:IN20:1:SOLNCTRL")
#! Field("MGNT:IN20:1:SOLNCTRL.FLNK",16777215,1,"MGNT:IN20:1:SOLNCTRL.FLNK")
#! Link("MGNT:IN20:1:SOLNCTRL.FLNK","MGNT:IN20:1:SOLNSWITCH")
#! Field("MGNT:IN20:1:SOLNCTRL.FFVL",16777215,1,"MGNT:IN20:1:SOLNCTRL.FFVL")
#! Record("MGNT:IN20:1:SOLNSWITCH",460,322,0,0,"MGNT:IN20:1:SOLNSWITCH")
#! Field("MGNT:IN20:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:IN20:1:SOLNSWITCH.DOL1")
#! Link("MGNT:IN20:1:SOLNSWITCH.DOL1","MGNT:IN20:1:SOLNCTRL.FFVL")
#! Field("MGNT:IN20:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:IN20:1:SOLNSWITCH.LNK1")
#! Field("MGNT:IN20:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:IN20:1:SOLNSWITCH.FLNK")
#! Record("MGNT:IN20:1:ALLSOLNSGO",240,96,0,0,"MGNT:IN20:1:ALLSOLNSGO")
#! Field("MGNT:IN20:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:IN20:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:IN20:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:IN20:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:IN20:1:ALLSOLNSGO.LNK1","MGNT:IN20:1:ALLSOLNS.VAL")
#! Record("MGNT:IN20:1:ALLSOLNS",540,102,0,0,"MGNT:IN20:1:ALLSOLNS")
#! Field("MGNT:IN20:1:ALLSOLNS.VAL",16777215,0,"MGNT:IN20:1:ALLSOLNS.VAL")
#! Field("MGNT:IN20:1:ALLSOLNS.FLNK",16777215,1,"MGNT:IN20:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:IN20:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:IN20:1:KICKSWITCH")
}

record(seq, "MGNT:IN20:1:KICKSWITCH") {
  field(DOL1, "MGNT:IN20:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:IN20:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:IN20:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:IN20:1:KICKCTRL")
}

record(seq, "MGNT:IN20:1:ALLKICKSGO") {
  field(DOL1, "MGNT:IN20:1:ALLSTAR")
  field(LNK1, "MGNT:IN20:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:IN20:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:IN20:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:IN20:1:KICKCTRL",20,10,0,0,"MGNT:IN20:1:KICKCTRL")
#! Field("MGNT:IN20:1:KICKCTRL.FLNK",16777215,1,"MGNT:IN20:1:KICKCTRL.FLNK")
#! Link("MGNT:IN20:1:KICKCTRL.FLNK","MGNT:IN20:1:KICKSWITCH")
#! Field("MGNT:IN20:1:KICKCTRL.FFVL",16777215,1,"MGNT:IN20:1:KICKCTRL.FFVL")
#! Record("MGNT:IN20:1:KICKSWITCH",460,322,0,0,"MGNT:IN20:1:KICKSWITCH")
#! Field("MGNT:IN20:1:KICKSWITCH.DOL1",16777215,0,"MGNT:IN20:1:KICKSWITCH.DOL1")
#! Link("MGNT:IN20:1:KICKSWITCH.DOL1","MGNT:IN20:1:KICKCTRL.FFVL")
#! Field("MGNT:IN20:1:KICKSWITCH.LNK1",16777215,1,"MGNT:IN20:1:KICKSWITCH.LNK1")
#! Field("MGNT:IN20:1:KICKSWITCH.FLNK",16777215,1,"MGNT:IN20:1:KICKSWITCH.FLNK")
#! Record("MGNT:IN20:1:ALLKICKSGO",240,96,0,0,"MGNT:IN20:1:ALLKICKSGO")
#! Field("MGNT:IN20:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:IN20:1:ALLKICKSGO.DOL1")
#! Field("MGNT:IN20:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:IN20:1:ALLKICKSGO.LNK1")
#! Link("MGNT:IN20:1:ALLKICKSGO.LNK1","MGNT:IN20:1:ALLKICKS.VAL")
#! Record("MGNT:IN20:1:ALLKICKS",540,102,0,0,"MGNT:IN20:1:ALLKICKS")
#! Field("MGNT:IN20:1:ALLKICKS.VAL",16777215,0,"MGNT:IN20:1:ALLKICKS.VAL")
#! Field("MGNT:IN20:1:ALLKICKS.FLNK",16777215,1,"MGNT:IN20:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:IN20:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:IN20:1:SEXTSWITCH")
}

record(seq, "MGNT:IN20:1:SEXTSWITCH") {
  field(DOL1, "MGNT:IN20:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:IN20:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:IN20:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:IN20:1:SEXTCTRL")
}

record(seq, "MGNT:IN20:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:IN20:1:ALLSTAR")
  field(LNK1, "MGNT:IN20:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:IN20:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:IN20:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:IN20:1:SEXTCTRL",20,10,0,0,"MGNT:IN20:1:SEXTCTRL")
#! Field("MGNT:IN20:1:SEXTCTRL.FLNK",16777215,1,"MGNT:IN20:1:SEXTCTRL.FLNK")
#! Link("MGNT:IN20:1:SEXTCTRL.FLNK","MGNT:IN20:1:SEXTSWITCH")
#! Field("MGNT:IN20:1:SEXTCTRL.FFVL",16777215,1,"MGNT:IN20:1:SEXTCTRL.FFVL")
#! Record("MGNT:IN20:1:SEXTSWITCH",460,322,0,0,"MGNT:IN20:1:SEXTSWITCH")
#! Field("MGNT:IN20:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:IN20:1:SEXTSWITCH.DOL1")
#! Link("MGNT:IN20:1:SEXTSWITCH.DOL1","MGNT:IN20:1:SEXTCTRL.FFVL")
#! Field("MGNT:IN20:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:IN20:1:SEXTSWITCH.LNK1")
#! Field("MGNT:IN20:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:IN20:1:SEXTSWITCH.FLNK")
#! Record("MGNT:IN20:1:ALLSEXTSGO",240,96,0,0,"MGNT:IN20:1:ALLSEXTSGO")
#! Field("MGNT:IN20:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:IN20:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:IN20:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:IN20:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:IN20:1:ALLSEXTSGO.LNK1","MGNT:IN20:1:ALLSEXTS.VAL")
#! Record("MGNT:IN20:1:ALLSEXTS",540,102,0,0,"MGNT:IN20:1:ALLSEXTS")
#! Field("MGNT:IN20:1:ALLSEXTS.VAL",16777215,0,"MGNT:IN20:1:ALLSEXTS.VAL")
#! Field("MGNT:IN20:1:ALLSEXTS.FLNK",16777215,1,"MGNT:IN20:1:ALLSEXTS.FLNK")

record (seq, "MGNT:IN20:1:ALLKICKSSEL"){
}
record (seq, "MGNT:IN20:1:ALLSEXTSSEL"){
}

record (seq, "MGNT:IN20:1:ALLBENDSSEL"){
  field (LNK1, "BEND:IN20:751:SELECT PP NMS")
  field (LNK2, "BEND:IN20:931:SELECT PP NMS")
  field (LNK3, "BEND:IN20:231:SELECT PP NMS")
  field (LNK4, "BEND:IN20:461:SELECT PP NMS")
  field (DOL1, "MGNT:IN20:1:ALLBENDS")
  field (DOL2, "MGNT:IN20:1:ALLBENDS")
  field (DOL3, "MGNT:IN20:1:ALLBENDS")
  field (DOL4, "MGNT:IN20:1:ALLBENDS")
}
record (seq, "MGNT:IN20:1:ALLBTRMSSEL"){
  field (LNK1, "BTRM:IN20:231:SELECT PP NMS")
  field (LNK2, "BTRM:IN20:661:SELECT PP NMS")
  field (LNK3, "BTRM:IN20:451:SELECT PP NMS")
  field (LNK4, "BTRM:IN20:475:SELECT PP NMS")
  field (LNK5, "BTRM:IN20:481:SELECT PP NMS")
  field (DOL1, "MGNT:IN20:1:ALLBTRMS")
  field (DOL2, "MGNT:IN20:1:ALLBTRMS")
  field (DOL3, "MGNT:IN20:1:ALLBTRMS")
  field (DOL4, "MGNT:IN20:1:ALLBTRMS")
  field (DOL5, "MGNT:IN20:1:ALLBTRMS")
}

record (seq, "MGNT:IN20:1:ALLLGPSSSEL"){
  field (DOL1, "MGNT:IN20:1:ALLLGPSS")
  field (DOL2, "MGNT:IN20:1:ALLLGPSS")
  field (LNK1, "LGPS:IN20:1:SELECT PP NMS")
  field (LNK2, "LGPS:IN20:2:SELECT PP NMS")
}
record (seq, "MGNT:IN20:1:ALLQUADSSEL"){
  field (DESC, "Select All QUADs")
  field (LNK1, "QUAD:IN20:425:SELECT PP NMS")
  field (LNK2, "QUAD:IN20:441:SELECT PP NMS")
  field (LNK3, "QUAD:IN20:511:SELECT PP NMS")
  field (LNK4, "QUAD:IN20:525:SELECT PP NMS")
  field (LNK5, "QUAD:IN20:631:SELECT PP NMS")
  field (LNK6, "QUAD:IN20:651:SELECT PP NMS")
  field (LNK7, "QUAD:IN20:771:SELECT PP NMS")
  field (LNK8, "QUAD:IN20:781:SELECT PP NMS")
  field (LNK9, "QUAD:IN20:811:SELECT PP NMS")
  field (LNKA, "QUAD:IN20:831:SELECT PP NMS")
  field (DOL1, "MGNT:IN20:1:ALLQUADS")
  field (DOL2, "MGNT:IN20:1:ALLQUADS")
  field (DOL3, "MGNT:IN20:1:ALLQUADS")
  field (DOL4, "MGNT:IN20:1:ALLQUADS")
  field (DOL5, "MGNT:IN20:1:ALLQUADS")
  field (DOL6, "MGNT:IN20:1:ALLQUADS")
  field (DOL7, "MGNT:IN20:1:ALLQUADS")
  field (DOL8, "MGNT:IN20:1:ALLQUADS")
  field (DOL9, "MGNT:IN20:1:ALLQUADS")
  field (DOLA, "MGNT:IN20:1:ALLQUADS")
  field (FLNK, "MGNT:IN20:1:ALLQUADSSEL2")
}
record (seq, "MGNT:IN20:1:ALLQUADSSEL2"){
  field (DESC, "Select All QUADs2")
  field (LNK1, "QUAD:IN20:121:SELECT PP NMS")
  field (LNK2, "QUAD:IN20:122:SELECT PP NMS")
  field (LNK3, "QUAD:IN20:361:SELECT PP NMS")
  field (LNK4, "QUAD:IN20:371:SELECT PP NMS")
  field (LNK5, "QUAD:IN20:941:SELECT PP NMS")
  field (LNK6, "QUAD:IN20:961:SELECT PP NMS")
  field (LNK7, "QUAD:IN20:731:SELECT PP NMS")
  field (DOL1, "MGNT:IN20:1:ALLQUADS")
  field (DOL2, "MGNT:IN20:1:ALLQUADS")
  field (DOL3, "MGNT:IN20:1:ALLQUADS")
  field (DOL4, "MGNT:IN20:1:ALLQUADS")
  field (DOL5, "MGNT:IN20:1:ALLQUADS")
  field (DOL6, "MGNT:IN20:1:ALLQUADS")
  field (DOL7, "MGNT:IN20:1:ALLQUADS")
}
record (seq, "MGNT:IN20:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:IN20:1:ALLXCORS")
  field (DOL2, "MGNT:IN20:1:ALLXCORS")
  field (DOL3, "MGNT:IN20:1:ALLXCORS")
  field (DOL4, "MGNT:IN20:1:ALLXCORS")
  field (DOL5, "MGNT:IN20:1:ALLXCORS")
  field (DOL6, "MGNT:IN20:1:ALLXCORS")
  field (DOL7, "MGNT:IN20:1:ALLXCORS")
  field (DOL8, "MGNT:IN20:1:ALLXCORS")
  field (DOL9, "MGNT:IN20:1:ALLXCORS")
  field (DOLA, "MGNT:IN20:1:ALLXCORS")
  field (LNK1, "XCOR:IN20:121:SELECT PP NMS")
  field (LNK2, "XCOR:IN20:221:SELECT PP NMS")
  field (LNK3, "XCOR:IN20:311:SELECT PP NMS")
  field (LNK4, "XCOR:IN20:341:SELECT PP NMS")
  field (LNK5, "XCOR:IN20:381:SELECT PP NMS")
  field (LNK6, "XCOR:IN20:491:SELECT PP NMS")
  field (LNK7, "XCOR:IN20:521:SELECT PP NMS")
  field (LNK8, "XCOR:IN20:641:SELECT PP NMS")
  field (LNK9, "XCOR:IN20:721:SELECT PP NMS")
  field (LNKA, "XCOR:IN20:761:SELECT PP NMS")
  field (FLNK, "MGNT:IN20:1:ALLXCORSSEL1 PP NMS")
}
record (seq, "MGNT:IN20:1:ALLXCORSSEL1"){
  field (LNK1, "XCOR:IN20:911:SELECT PP NMS")
  field (LNK2, "XCOR:IN20:951:SELECT PP NMS")
  field (LNK3, "XCOR:IN20:411:SELECT PP NMS")
  field (LNK4, "XCOR:IN20:811:SELECT PP NMS")
  field (LNK5, "XCOR:IN20:831:SELECT PP NMS")
  field (DOL1, "MGNT:IN20:1:ALLXCORS")
  field (DOL2, "MGNT:IN20:1:ALLXCORS")
  field (DOL3, "MGNT:IN20:1:ALLXCORS")
  field (DOL4, "MGNT:IN20:1:ALLXCORS")
  field (DOL5, "MGNT:IN20:1:ALLXCORS")
}
record (seq, "MGNT:IN20:1:ALLYCORSSEL"){
  field (LNK1, "YCOR:IN20:122:SELECT PP NMS")
  field (LNK2, "YCOR:IN20:222:SELECT PP NMS")
  field (LNK3, "YCOR:IN20:312:SELECT PP NMS")
  field (LNK4, "YCOR:IN20:342:SELECT PP NMS")
  field (LNK5, "YCOR:IN20:382:SELECT PP NMS")
  field (LNK6, "YCOR:IN20:492:SELECT PP NMS")
  field (LNK7, "YCOR:IN20:522:SELECT PP NMS")
  field (LNK8, "YCOR:IN20:642:SELECT PP NMS")
  field (LNK9, "YCOR:IN20:722:SELECT PP NMS")
  field (LNKA, "YCOR:IN20:762:SELECT PP NMS")
  field (DOL1, "MGNT:IN20:1:ALLYCORS")
  field (DOL2, "MGNT:IN20:1:ALLYCORS")
  field (DOL3, "MGNT:IN20:1:ALLYCORS")
  field (DOL4, "MGNT:IN20:1:ALLYCORS")
  field (DOL5, "MGNT:IN20:1:ALLYCORS")
  field (DOL6, "MGNT:IN20:1:ALLYCORS")
  field (DOL7, "MGNT:IN20:1:ALLYCORS")
  field (DOL8, "MGNT:IN20:1:ALLYCORS")
  field (DOL9, "MGNT:IN20:1:ALLYCORS")
  field (DOLA, "MGNT:IN20:1:ALLYCORS")
  field (FLNK, "MGNT:IN20:1:ALLYCORSSEL1")
}
record (seq, "MGNT:IN20:1:ALLYCORSSEL1"){
  field (DOL1, "MGNT:IN20:1:ALLYCORS")
  field (DOL2, "MGNT:IN20:1:ALLYCORS")
  field (DOL3, "MGNT:IN20:1:ALLYCORS")
  field (DOL4, "MGNT:IN20:1:ALLYCORS")
  field (DOL5, "MGNT:IN20:1:ALLYCORS")
  field (LNK1, "YCOR:IN20:812:SELECT PP NMS")
  field (LNK2, "YCOR:IN20:832:SELECT PP NMS")
  field (LNK3, "YCOR:IN20:912:SELECT PP NMS")
  field (LNK4, "YCOR:IN20:952:SELECT PP NMS")
  field (LNK5, "YCOR:IN20:412:SELECT PP NMS")
}
record (seq, "MGNT:IN20:1:ALLSOLNSSEL"){
  field (DOL1, "MGNT:IN20:1:ALLSOLNS")
  field (DOL2, "MGNT:IN20:1:ALLSOLNS")
  field (DOL3, "MGNT:IN20:1:ALLSOLNS")
  field (LNK1, "SOLN:IN20:111:SELECT PP NMS")
  field (LNK2, "SOLN:IN20:121:SELECT PP NMS")
  field (LNK3, "SOLN:IN20:311:SELECT PP NMS")
}
record (seq, "MGNT:IN20:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func0")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:IN20:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:IN20:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:IN20:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:IN20:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:IN20:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:IN20:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:IN20:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:IN20:1:ALLFUNCGO1")
}
record (seq, "MGNT:IN20:1:ALLFUNCGO1") {
  field (DESC, "Process CTRL func1")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:IN20:1:SOLNFUNCGO.PROC")
  field (LNK2, "MGNT:IN20:1:KICKFUNCGO.PROC")
  field (LNK3, "MGNT:IN20:1:SEXTFUNCGO.PROC")
  field (LNK4, "MGNT:IN20:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:IN20:1:CTRLCLEAR")
}

record (fanout, "MGNT:IN20:1:KICKFUNCGO") {
  field (DESC, "Process All KICKs")
  field (FLNK, "MGNT:IN20:1:CTRLCLEAR")
}
record (fanout, "MGNT:IN20:1:SEXTFUNCGO") {
  field (DESC, "Process All SEXTs")
  field (FLNK, "MGNT:IN20:1:CTRLCLEAR")
}

record (fanout, "MGNT:IN20:1:SOLNFUNCGO") {
  field (DESC, "Process All SOLNs")
  field (LNK1, "SOLN:IN20:111:ALLFUNCGO")
  field (LNK2, "SOLN:IN20:121:ALLFUNCGO")
  field (LNK3, "SOLN:IN20:311:ALLFUNCGO")
  field (FLNK, "MGNT:IN20:1:CTRLCLEAR")
}
record (fanout, "MGNT:IN20:1:BENDFUNCGO") {
  field (DESC, "Process All BENDs")
  field (LNK1, "BEND:IN20:751:ALLFUNCGO")
  field (LNK2, "BEND:IN20:931:ALLFUNCGO")
  field (LNK3, "BEND:IN20:231:ALLFUNCGO")
  field (LNK4, "BEND:IN20:461:ALLFUNCGO")
  field (FLNK, "MGNT:IN20:1:CTRLCLEAR")
}
record (fanout, "MGNT:IN20:1:BTRMFUNCGO"){
  field (DESC, "Process All BTRMs")
  field (LNK1, "BTRM:IN20:231:ALLFUNCGO")
  field (LNK2, "BTRM:IN20:661:ALLFUNCGO")
  field (LNK3, "BTRM:IN20:451:ALLFUNCGO")
  field (LNK4, "BTRM:IN20:475:ALLFUNCGO")
  field (LNK5, "BTRM:IN20:481:ALLFUNCGO")
  field (FLNK, "MGNT:IN20:1:CTRLCLEAR")
}

record (fanout, "MGNT:IN20:1:QUADFUNCGO"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:IN20:425:ALLFUNCGO")
  field (LNK2, "QUAD:IN20:441:ALLFUNCGO")
  field (LNK3, "QUAD:IN20:511:ALLFUNCGO")
  field (LNK4, "QUAD:IN20:525:ALLFUNCGO")
  field (LNK5, "QUAD:IN20:631:ALLFUNCGO")
  field (LNK6, "QUAD:IN20:651:ALLFUNCGO")
  field (FLNK, "MGNT:IN20:1:QUADFUNCGO1")
}
record (fanout, "MGNT:IN20:1:QUADFUNCGO1"){
  field (DESC, "Process All QUADs1")
  field (LNK1, "QUAD:IN20:771:ALLFUNCGO")
  field (LNK2, "QUAD:IN20:781:ALLFUNCGO")
  field (LNK3, "QUAD:IN20:811:ALLFUNCGO")
  field (LNK4, "QUAD:IN20:831:ALLFUNCGO")
  field (LNK5, "QUAD:IN20:121:ALLFUNCGO")
  field (LNK6, "QUAD:IN20:122:ALLFUNCGO")
  field (FLNK, "MGNT:IN20:1:QUADFUNCGO2")
}
record (fanout, "MGNT:IN20:1:QUADFUNCGO2"){
  field (DESC, "Process All QUADs2")
  field (LNK1, "QUAD:IN20:361:ALLFUNCGO")
  field (LNK2, "QUAD:IN20:371:ALLFUNCGO")
  field (LNK3, "QUAD:IN20:941:ALLFUNCGO")
  field (LNK4, "QUAD:IN20:961:ALLFUNCGO")
  field (LNK5, "QUAD:IN20:731:ALLFUNCGO")
  field (FLNK, "MGNT:IN20:1:CTRLCLEAR")
}
record (fanout, "MGNT:IN20:1:XCORFUNCGO"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:IN20:491:ALLFUNCGO")
  field (LNK2, "XCOR:IN20:521:ALLFUNCGO")
  field (LNK3, "XCOR:IN20:641:ALLFUNCGO")
  field (LNK4, "XCOR:IN20:721:ALLFUNCGO")
  field (LNK5, "XCOR:IN20:761:ALLFUNCGO")
  field (LNK6, "XCOR:IN20:811:ALLFUNCGO")
  field (FLNK, "MGNT:IN20:1:XCORFUNCGO1")
}
record (fanout, "MGNT:IN20:1:XCORFUNCGO1"){
  field (DESC, "Process All XCORs1")
  field (LNK1, "XCOR:IN20:831:ALLFUNCGO")
  field (LNK2, "XCOR:IN20:221:ALLFUNCGO")
  field (LNK3, "XCOR:IN20:121:ALLFUNCGO")
  field (LNK4, "XCOR:IN20:311:ALLFUNCGO")
  field (LNK5, "XCOR:IN20:341:ALLFUNCGO")
  field (LNK6, "XCOR:IN20:381:ALLFUNCGO")
  field (FLNK, "MGNT:IN20:1:XCORFUNCGO2")
}
record (fanout, "MGNT:IN20:1:XCORFUNCGO2"){
  field (DESC, "Process All XCORs2")
  field (LNK1, "XCOR:IN20:911:ALLFUNCGO")
  field (LNK2, "XCOR:IN20:951:ALLFUNCGO")
  field (LNK3, "XCOR:IN20:411:ALLFUNCGO")
  field (FLNK, "MGNT:IN20:1:CTRLCLEAR")
}
record (fanout, "MGNT:IN20:1:YCORFUNCGO"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:IN20:912:ALLFUNCGO")
  field (LNK2, "YCOR:IN20:952:ALLFUNCGO")
  field (LNK3, "YCOR:IN20:492:ALLFUNCGO")
  field (LNK4, "YCOR:IN20:522:ALLFUNCGO")
  field (LNK5, "YCOR:IN20:642:ALLFUNCGO")
  field (LNK6, "YCOR:IN20:722:ALLFUNCGO")
  field (FLNK, "MGNT:IN20:1:YCORFUNCGO1")
}
record (fanout, "MGNT:IN20:1:YCORFUNCGO1"){
  field (DESC, "Process All YCORs1")
  field (LNK1, "YCOR:IN20:762:ALLFUNCGO")
  field (LNK2, "YCOR:IN20:812:ALLFUNCGO")
  field (LNK3, "YCOR:IN20:832:ALLFUNCGO")
  field (LNK4, "YCOR:IN20:222:ALLFUNCGO")
  field (LNK5, "YCOR:IN20:122:ALLFUNCGO")
  field (LNK6, "YCOR:IN20:312:ALLFUNCGO")
  field (FLNK, "MGNT:IN20:1:YCORFUNCGO2")
}
record (fanout, "MGNT:IN20:1:YCORFUNCGO2"){
  field (DESC, "Process All YCORs2")
  field (LNK1, "YCOR:IN20:342:ALLFUNCGO")
  field (LNK2, "YCOR:IN20:382:ALLFUNCGO")
  field (LNK3, "YCOR:IN20:412:ALLFUNCGO")
  field (FLNK, "MGNT:IN20:1:CTRLCLEAR")
}
record (fanout, "MGNT:IN20:1:LGPSFUNCGO"){
  field (DESC, "Process All LGPSs")
  field (LNK1, "LGPS:IN20:1:ALLFUNCGO")
  field (LNK2, "LGPS:IN20:2:ALLFUNCGO")
  field (FLNK, "MGNT:IN20:1:CTRLCLEAR")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:IN20:231:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "BEND:IN20:231:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:IN20:231:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:IN20:231:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:IN20:231:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:IN20:231:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:IN20:231:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:IN20:231:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:IN20:231:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:IN20:231:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:IN20:231:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:IN20:231:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:IN20:231:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:IN20:231:EDES.PROC PP")
    field(LNK2, "BEND:IN20:231:EACT.PROC PP")
    field(LNK3, "BEND:IN20:231:EERR.DISA PP")
    field(LNK4, "BEND:IN20:231:ECON.PROC PP")
    field(LNK5, "BEND:IN20:231:BMAGX.PROC PP")
    field(LNK6, "BEND:IN20:231:BMAGY.PROC PP")
    field(LNK7, "BEND:IN20:231:BLEM.PROC PP")
    field(LNK8, "BEND:IN20:231:BMOD.PROC PP")
    field(LNK9, "BEND:IN20:231:EDESSAVE.PROC PP")
    field(LNKA, "BEND:IN20:231:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:IN20:231:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:IN20:231:BMAX")
  field(DOL2, "BEND:IN20:231:BMAX")
  field(DOL3, "BEND:IN20:231:BMAX")
  field(DOL4, "BEND:IN20:231:BMIN")
  field(DOL5, "BEND:IN20:231:BMIN")
  field(DOL6, "BEND:IN20:231:BMIN")
  field(LNK1, "BEND:IN20:231:BMAGX.HOPR")
  field(LNK2, "BEND:IN20:231:BMAGY.HOPR")
  field(LNK3, "BEND:IN20:231:BLEM.HOPR")
  field(LNK4, "BEND:IN20:231:BMAGX.LOPR PP")
  field(LNK5, "BEND:IN20:231:BMAGY.LOPR PP")
  field(LNK6, "BEND:IN20:231:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:231:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:231:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:IN20:231:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:IN20:231:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:IN20:231:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:231:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:231:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:IN20:231:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:231:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:IN20:231:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:IN20:231:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:IN20:231:EDES NPP MS")
  field(INPB, "BEND:IN20:231:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:IN20:461:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "BEND:IN20:461:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:IN20:461:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:IN20:461:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:IN20:461:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:IN20:461:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:IN20:461:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:IN20:461:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:IN20:461:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:IN20:461:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:IN20:461:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:IN20:461:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:IN20:461:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:IN20:461:EDES.PROC PP")
    field(LNK2, "BEND:IN20:461:EACT.PROC PP")
    field(LNK3, "BEND:IN20:461:EERR.DISA PP")
    field(LNK4, "BEND:IN20:461:ECON.PROC PP")
    field(LNK5, "BEND:IN20:461:BMAGX.PROC PP")
    field(LNK6, "BEND:IN20:461:BMAGY.PROC PP")
    field(LNK7, "BEND:IN20:461:BLEM.PROC PP")
    field(LNK8, "BEND:IN20:461:BMOD.PROC PP")
    field(LNK9, "BEND:IN20:461:EDESSAVE.PROC PP")
    field(LNKA, "BEND:IN20:461:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:IN20:461:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:IN20:461:BMAX")
  field(DOL2, "BEND:IN20:461:BMAX")
  field(DOL3, "BEND:IN20:461:BMAX")
  field(DOL4, "BEND:IN20:461:BMIN")
  field(DOL5, "BEND:IN20:461:BMIN")
  field(DOL6, "BEND:IN20:461:BMIN")
  field(LNK1, "BEND:IN20:461:BMAGX.HOPR")
  field(LNK2, "BEND:IN20:461:BMAGY.HOPR")
  field(LNK3, "BEND:IN20:461:BLEM.HOPR")
  field(LNK4, "BEND:IN20:461:BMAGX.LOPR PP")
  field(LNK5, "BEND:IN20:461:BMAGY.LOPR PP")
  field(LNK6, "BEND:IN20:461:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:461:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:461:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:IN20:461:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:IN20:461:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:IN20:461:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:461:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:461:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:IN20:461:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:461:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:IN20:461:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:IN20:461:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:IN20:461:EDES NPP MS")
  field(INPB, "BEND:IN20:461:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:IN20:751:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "BEND:IN20:751:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:IN20:751:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:IN20:751:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:IN20:751:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:IN20:751:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:IN20:751:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:IN20:751:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:IN20:751:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:IN20:751:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:IN20:751:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:IN20:751:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:IN20:751:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:IN20:751:EDES.PROC PP")
    field(LNK2, "BEND:IN20:751:EACT.PROC PP")
    field(LNK3, "BEND:IN20:751:EERR.DISA PP")
    field(LNK4, "BEND:IN20:751:ECON.PROC PP")
    field(LNK5, "BEND:IN20:751:BMAGX.PROC PP")
    field(LNK6, "BEND:IN20:751:BMAGY.PROC PP")
    field(LNK7, "BEND:IN20:751:BLEM.PROC PP")
    field(LNK8, "BEND:IN20:751:BMOD.PROC PP")
    field(LNK9, "BEND:IN20:751:EDESSAVE.PROC PP")
    field(LNKA, "BEND:IN20:751:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:IN20:751:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:IN20:751:BMAX")
  field(DOL2, "BEND:IN20:751:BMAX")
  field(DOL3, "BEND:IN20:751:BMAX")
  field(DOL4, "BEND:IN20:751:BMIN")
  field(DOL5, "BEND:IN20:751:BMIN")
  field(DOL6, "BEND:IN20:751:BMIN")
  field(LNK1, "BEND:IN20:751:BMAGX.HOPR")
  field(LNK2, "BEND:IN20:751:BMAGY.HOPR")
  field(LNK3, "BEND:IN20:751:BLEM.HOPR")
  field(LNK4, "BEND:IN20:751:BMAGX.LOPR PP")
  field(LNK5, "BEND:IN20:751:BMAGY.LOPR PP")
  field(LNK6, "BEND:IN20:751:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:751:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:751:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:IN20:751:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:IN20:751:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:IN20:751:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:751:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:751:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:IN20:751:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:751:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:IN20:751:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:IN20:751:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:IN20:751:EDES NPP MS")
  field(INPB, "BEND:IN20:751:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:IN20:931:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "BEND:IN20:931:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:IN20:931:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:IN20:931:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:IN20:931:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:IN20:931:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:IN20:931:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:IN20:931:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:IN20:931:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:IN20:931:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:IN20:931:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:IN20:931:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:IN20:931:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:IN20:931:EDES.PROC PP")
    field(LNK2, "BEND:IN20:931:EACT.PROC PP")
    field(LNK3, "BEND:IN20:931:EERR.DISA PP")
    field(LNK4, "BEND:IN20:931:ECON.PROC PP")
    field(LNK5, "BEND:IN20:931:BMAGX.PROC PP")
    field(LNK6, "BEND:IN20:931:BMAGY.PROC PP")
    field(LNK7, "BEND:IN20:931:BLEM.PROC PP")
    field(LNK8, "BEND:IN20:931:BMOD.PROC PP")
    field(LNK9, "BEND:IN20:931:EDESSAVE.PROC PP")
    field(LNKA, "BEND:IN20:931:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:IN20:931:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:IN20:931:BMAX")
  field(DOL2, "BEND:IN20:931:BMAX")
  field(DOL3, "BEND:IN20:931:BMAX")
  field(DOL4, "BEND:IN20:931:BMIN")
  field(DOL5, "BEND:IN20:931:BMIN")
  field(DOL6, "BEND:IN20:931:BMIN")
  field(LNK1, "BEND:IN20:931:BMAGX.HOPR")
  field(LNK2, "BEND:IN20:931:BMAGY.HOPR")
  field(LNK3, "BEND:IN20:931:BLEM.HOPR")
  field(LNK4, "BEND:IN20:931:BMAGX.LOPR PP")
  field(LNK5, "BEND:IN20:931:BMAGY.LOPR PP")
  field(LNK6, "BEND:IN20:931:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:931:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:931:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:IN20:931:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:IN20:931:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:IN20:931:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:931:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:931:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:IN20:931:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:931:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:IN20:931:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:IN20:931:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:IN20:931:EDES NPP MS")
  field(INPB, "BEND:IN20:931:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:IN20:231:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "BTRM:IN20:231:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:IN20:231:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:IN20:231:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:IN20:231:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:IN20:231:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:IN20:231:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:IN20:231:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:IN20:231:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:IN20:231:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:IN20:231:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:IN20:231:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:IN20:231:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:IN20:231:EDES.PROC PP")
    field(LNK2, "BTRM:IN20:231:EACT.PROC PP")
    field(LNK3, "BTRM:IN20:231:EERR.DISA PP")
    field(LNK4, "BTRM:IN20:231:ECON.PROC PP")
    field(LNK5, "BTRM:IN20:231:BMAGX.PROC PP")
    field(LNK6, "BTRM:IN20:231:BMAGY.PROC PP")
    field(LNK7, "BTRM:IN20:231:BLEM.PROC PP")
    field(LNK8, "BTRM:IN20:231:BMOD.PROC PP")
    field(LNK9, "BTRM:IN20:231:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:IN20:231:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:IN20:231:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:IN20:231:BMAX")
  field(DOL2, "BTRM:IN20:231:BMAX")
  field(DOL3, "BTRM:IN20:231:BMAX")
  field(DOL4, "BTRM:IN20:231:BMIN")
  field(DOL5, "BTRM:IN20:231:BMIN")
  field(DOL6, "BTRM:IN20:231:BMIN")
  field(LNK1, "BTRM:IN20:231:BMAGX.HOPR")
  field(LNK2, "BTRM:IN20:231:BMAGY.HOPR")
  field(LNK3, "BTRM:IN20:231:BLEM.HOPR")
  field(LNK4, "BTRM:IN20:231:BMAGX.LOPR PP")
  field(LNK5, "BTRM:IN20:231:BMAGY.LOPR PP")
  field(LNK6, "BTRM:IN20:231:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:IN20:231:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:IN20:231:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:IN20:231:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:IN20:231:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:IN20:231:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:IN20:231:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:IN20:231:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:IN20:231:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:IN20:231:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:IN20:231:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:IN20:231:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:IN20:231:EDES NPP MS")
  field(INPB, "BTRM:IN20:231:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:IN20:451:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "BTRM:IN20:451:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:IN20:451:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:IN20:451:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:IN20:451:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:IN20:451:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:IN20:451:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:IN20:451:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:IN20:451:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:IN20:451:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:IN20:451:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:IN20:451:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:IN20:451:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:IN20:451:EDES.PROC PP")
    field(LNK2, "BTRM:IN20:451:EACT.PROC PP")
    field(LNK3, "BTRM:IN20:451:EERR.DISA PP")
    field(LNK4, "BTRM:IN20:451:ECON.PROC PP")
    field(LNK5, "BTRM:IN20:451:BMAGX.PROC PP")
    field(LNK6, "BTRM:IN20:451:BMAGY.PROC PP")
    field(LNK7, "BTRM:IN20:451:BLEM.PROC PP")
    field(LNK8, "BTRM:IN20:451:BMOD.PROC PP")
    field(LNK9, "BTRM:IN20:451:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:IN20:451:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:IN20:451:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:IN20:451:BMAX")
  field(DOL2, "BTRM:IN20:451:BMAX")
  field(DOL3, "BTRM:IN20:451:BMAX")
  field(DOL4, "BTRM:IN20:451:BMIN")
  field(DOL5, "BTRM:IN20:451:BMIN")
  field(DOL6, "BTRM:IN20:451:BMIN")
  field(LNK1, "BTRM:IN20:451:BMAGX.HOPR")
  field(LNK2, "BTRM:IN20:451:BMAGY.HOPR")
  field(LNK3, "BTRM:IN20:451:BLEM.HOPR")
  field(LNK4, "BTRM:IN20:451:BMAGX.LOPR PP")
  field(LNK5, "BTRM:IN20:451:BMAGY.LOPR PP")
  field(LNK6, "BTRM:IN20:451:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:IN20:451:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:IN20:451:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:IN20:451:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:IN20:451:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:IN20:451:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:IN20:451:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:IN20:451:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:IN20:451:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:IN20:451:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:IN20:451:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:IN20:451:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:IN20:451:EDES NPP MS")
  field(INPB, "BTRM:IN20:451:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:IN20:475:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "BTRM:IN20:475:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:IN20:475:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:IN20:475:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:IN20:475:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:IN20:475:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:IN20:475:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:IN20:475:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:IN20:475:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:IN20:475:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:IN20:475:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:IN20:475:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:IN20:475:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:IN20:475:EDES.PROC PP")
    field(LNK2, "BTRM:IN20:475:EACT.PROC PP")
    field(LNK3, "BTRM:IN20:475:EERR.DISA PP")
    field(LNK4, "BTRM:IN20:475:ECON.PROC PP")
    field(LNK5, "BTRM:IN20:475:BMAGX.PROC PP")
    field(LNK6, "BTRM:IN20:475:BMAGY.PROC PP")
    field(LNK7, "BTRM:IN20:475:BLEM.PROC PP")
    field(LNK8, "BTRM:IN20:475:BMOD.PROC PP")
    field(LNK9, "BTRM:IN20:475:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:IN20:475:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:IN20:475:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:IN20:475:BMAX")
  field(DOL2, "BTRM:IN20:475:BMAX")
  field(DOL3, "BTRM:IN20:475:BMAX")
  field(DOL4, "BTRM:IN20:475:BMIN")
  field(DOL5, "BTRM:IN20:475:BMIN")
  field(DOL6, "BTRM:IN20:475:BMIN")
  field(LNK1, "BTRM:IN20:475:BMAGX.HOPR")
  field(LNK2, "BTRM:IN20:475:BMAGY.HOPR")
  field(LNK3, "BTRM:IN20:475:BLEM.HOPR")
  field(LNK4, "BTRM:IN20:475:BMAGX.LOPR PP")
  field(LNK5, "BTRM:IN20:475:BMAGY.LOPR PP")
  field(LNK6, "BTRM:IN20:475:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:IN20:475:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:IN20:475:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:IN20:475:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:IN20:475:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:IN20:475:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:IN20:475:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:IN20:475:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:IN20:475:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:IN20:475:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:IN20:475:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:IN20:475:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:IN20:475:EDES NPP MS")
  field(INPB, "BTRM:IN20:475:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:IN20:481:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "BTRM:IN20:481:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:IN20:481:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:IN20:481:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:IN20:481:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:IN20:481:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:IN20:481:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:IN20:481:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:IN20:481:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:IN20:481:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:IN20:481:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:IN20:481:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:IN20:481:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:IN20:481:EDES.PROC PP")
    field(LNK2, "BTRM:IN20:481:EACT.PROC PP")
    field(LNK3, "BTRM:IN20:481:EERR.DISA PP")
    field(LNK4, "BTRM:IN20:481:ECON.PROC PP")
    field(LNK5, "BTRM:IN20:481:BMAGX.PROC PP")
    field(LNK6, "BTRM:IN20:481:BMAGY.PROC PP")
    field(LNK7, "BTRM:IN20:481:BLEM.PROC PP")
    field(LNK8, "BTRM:IN20:481:BMOD.PROC PP")
    field(LNK9, "BTRM:IN20:481:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:IN20:481:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:IN20:481:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:IN20:481:BMAX")
  field(DOL2, "BTRM:IN20:481:BMAX")
  field(DOL3, "BTRM:IN20:481:BMAX")
  field(DOL4, "BTRM:IN20:481:BMIN")
  field(DOL5, "BTRM:IN20:481:BMIN")
  field(DOL6, "BTRM:IN20:481:BMIN")
  field(LNK1, "BTRM:IN20:481:BMAGX.HOPR")
  field(LNK2, "BTRM:IN20:481:BMAGY.HOPR")
  field(LNK3, "BTRM:IN20:481:BLEM.HOPR")
  field(LNK4, "BTRM:IN20:481:BMAGX.LOPR PP")
  field(LNK5, "BTRM:IN20:481:BMAGY.LOPR PP")
  field(LNK6, "BTRM:IN20:481:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:IN20:481:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:IN20:481:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:IN20:481:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:IN20:481:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:IN20:481:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:IN20:481:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:IN20:481:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:IN20:481:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:IN20:481:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:IN20:481:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:IN20:481:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:IN20:481:EDES NPP MS")
  field(INPB, "BTRM:IN20:481:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:IN20:661:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "BTRM:IN20:661:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:IN20:661:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:IN20:661:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:IN20:661:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:IN20:661:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:IN20:661:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:IN20:661:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:IN20:661:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:IN20:661:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:IN20:661:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:IN20:661:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:IN20:661:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:IN20:661:EDES.PROC PP")
    field(LNK2, "BTRM:IN20:661:EACT.PROC PP")
    field(LNK3, "BTRM:IN20:661:EERR.DISA PP")
    field(LNK4, "BTRM:IN20:661:ECON.PROC PP")
    field(LNK5, "BTRM:IN20:661:BMAGX.PROC PP")
    field(LNK6, "BTRM:IN20:661:BMAGY.PROC PP")
    field(LNK7, "BTRM:IN20:661:BLEM.PROC PP")
    field(LNK8, "BTRM:IN20:661:BMOD.PROC PP")
    field(LNK9, "BTRM:IN20:661:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:IN20:661:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:IN20:661:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:IN20:661:BMAX")
  field(DOL2, "BTRM:IN20:661:BMAX")
  field(DOL3, "BTRM:IN20:661:BMAX")
  field(DOL4, "BTRM:IN20:661:BMIN")
  field(DOL5, "BTRM:IN20:661:BMIN")
  field(DOL6, "BTRM:IN20:661:BMIN")
  field(LNK1, "BTRM:IN20:661:BMAGX.HOPR")
  field(LNK2, "BTRM:IN20:661:BMAGY.HOPR")
  field(LNK3, "BTRM:IN20:661:BLEM.HOPR")
  field(LNK4, "BTRM:IN20:661:BMAGX.LOPR PP")
  field(LNK5, "BTRM:IN20:661:BMAGY.LOPR PP")
  field(LNK6, "BTRM:IN20:661:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:IN20:661:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:IN20:661:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:IN20:661:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:IN20:661:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:IN20:661:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:IN20:661:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:IN20:661:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:IN20:661:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:IN20:661:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:IN20:661:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:IN20:661:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:IN20:661:EDES NPP MS")
  field(INPB, "BTRM:IN20:661:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:IN20:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "LGPS:IN20:1:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:IN20:1:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:IN20:1:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:IN20:1:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:IN20:1:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:IN20:1:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:IN20:1:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:IN20:1:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:IN20:1:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:IN20:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:IN20:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:IN20:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:IN20:1:EDES.PROC PP")
    field(LNK2, "LGPS:IN20:1:EACT.PROC PP")
    field(LNK3, "LGPS:IN20:1:EERR.DISA PP")
    field(LNK4, "LGPS:IN20:1:ECON.PROC PP")
    field(LNK5, "LGPS:IN20:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:IN20:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:IN20:1:BLEM.PROC PP")
    field(LNK8, "LGPS:IN20:1:BMOD.PROC PP")
    field(LNK9, "LGPS:IN20:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:IN20:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:IN20:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:IN20:1:BMAX")
  field(DOL2, "LGPS:IN20:1:BMAX")
  field(DOL3, "LGPS:IN20:1:BMAX")
  field(DOL4, "LGPS:IN20:1:BMIN")
  field(DOL5, "LGPS:IN20:1:BMIN")
  field(DOL6, "LGPS:IN20:1:BMIN")
  field(LNK1, "LGPS:IN20:1:BMAGX.HOPR")
  field(LNK2, "LGPS:IN20:1:BMAGY.HOPR")
  field(LNK3, "LGPS:IN20:1:BLEM.HOPR")
  field(LNK4, "LGPS:IN20:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:IN20:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:IN20:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:IN20:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:IN20:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:IN20:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:IN20:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:IN20:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:IN20:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:IN20:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:IN20:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:IN20:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:IN20:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:IN20:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:IN20:1:EDES NPP MS")
  field(INPB, "LGPS:IN20:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:IN20:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "LGPS:IN20:2:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:IN20:2:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:IN20:2:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:IN20:2:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:IN20:2:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:IN20:2:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:IN20:2:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:IN20:2:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:IN20:2:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:IN20:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:IN20:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:IN20:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:IN20:2:EDES.PROC PP")
    field(LNK2, "LGPS:IN20:2:EACT.PROC PP")
    field(LNK3, "LGPS:IN20:2:EERR.DISA PP")
    field(LNK4, "LGPS:IN20:2:ECON.PROC PP")
    field(LNK5, "LGPS:IN20:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:IN20:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:IN20:2:BLEM.PROC PP")
    field(LNK8, "LGPS:IN20:2:BMOD.PROC PP")
    field(LNK9, "LGPS:IN20:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:IN20:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:IN20:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:IN20:2:BMAX")
  field(DOL2, "LGPS:IN20:2:BMAX")
  field(DOL3, "LGPS:IN20:2:BMAX")
  field(DOL4, "LGPS:IN20:2:BMIN")
  field(DOL5, "LGPS:IN20:2:BMIN")
  field(DOL6, "LGPS:IN20:2:BMIN")
  field(LNK1, "LGPS:IN20:2:BMAGX.HOPR")
  field(LNK2, "LGPS:IN20:2:BMAGY.HOPR")
  field(LNK3, "LGPS:IN20:2:BLEM.HOPR")
  field(LNK4, "LGPS:IN20:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:IN20:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:IN20:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:IN20:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:IN20:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:IN20:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:IN20:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:IN20:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:IN20:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:IN20:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:IN20:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:IN20:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:IN20:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:IN20:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:IN20:2:EDES NPP MS")
  field(INPB, "LGPS:IN20:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:121:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:121:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:121:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:121:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:121:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:121:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:121:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:121:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:121:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:121:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:121:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:121:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:121:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:121:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:121:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:121:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:121:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:121:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:121:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:121:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:121:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:121:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:121:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:121:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:121:BMAX")
  field(DOL2, "QUAD:IN20:121:BMAX")
  field(DOL3, "QUAD:IN20:121:BMAX")
  field(DOL4, "QUAD:IN20:121:BMIN")
  field(DOL5, "QUAD:IN20:121:BMIN")
  field(DOL6, "QUAD:IN20:121:BMIN")
  field(LNK1, "QUAD:IN20:121:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:121:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:121:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:121:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:121:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:121:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:121:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:121:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:121:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:121:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:121:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:121:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:121:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:121:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:121:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:121:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:121:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:121:EDES NPP MS")
  field(INPB, "QUAD:IN20:121:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:122:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:122:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:122:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:122:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:122:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:122:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:122:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:122:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:122:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:122:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:122:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:122:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:122:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:122:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:122:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:122:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:122:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:122:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:122:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:122:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:122:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:122:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:122:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:122:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:122:BMAX")
  field(DOL2, "QUAD:IN20:122:BMAX")
  field(DOL3, "QUAD:IN20:122:BMAX")
  field(DOL4, "QUAD:IN20:122:BMIN")
  field(DOL5, "QUAD:IN20:122:BMIN")
  field(DOL6, "QUAD:IN20:122:BMIN")
  field(LNK1, "QUAD:IN20:122:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:122:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:122:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:122:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:122:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:122:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:122:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:122:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:122:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:122:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:122:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:122:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:122:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:122:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:122:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:122:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:122:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:122:EDES NPP MS")
  field(INPB, "QUAD:IN20:122:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:361:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:361:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:361:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:361:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:361:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:361:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:361:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:361:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:361:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:361:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:361:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:361:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:361:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:361:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:361:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:361:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:361:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:361:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:361:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:361:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:361:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:361:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:361:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:361:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:361:BMAX")
  field(DOL2, "QUAD:IN20:361:BMAX")
  field(DOL3, "QUAD:IN20:361:BMAX")
  field(DOL4, "QUAD:IN20:361:BMIN")
  field(DOL5, "QUAD:IN20:361:BMIN")
  field(DOL6, "QUAD:IN20:361:BMIN")
  field(LNK1, "QUAD:IN20:361:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:361:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:361:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:361:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:361:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:361:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:361:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:361:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:361:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:361:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:361:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:361:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:361:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:361:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:361:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:361:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:361:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:361:EDES NPP MS")
  field(INPB, "QUAD:IN20:361:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:371:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:371:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:371:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:371:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:371:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:371:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:371:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:371:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:371:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:371:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:371:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:371:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:371:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:371:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:371:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:371:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:371:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:371:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:371:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:371:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:371:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:371:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:371:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:371:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:371:BMAX")
  field(DOL2, "QUAD:IN20:371:BMAX")
  field(DOL3, "QUAD:IN20:371:BMAX")
  field(DOL4, "QUAD:IN20:371:BMIN")
  field(DOL5, "QUAD:IN20:371:BMIN")
  field(DOL6, "QUAD:IN20:371:BMIN")
  field(LNK1, "QUAD:IN20:371:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:371:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:371:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:371:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:371:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:371:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:371:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:371:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:371:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:371:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:371:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:371:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:371:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:371:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:371:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:371:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:371:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:371:EDES NPP MS")
  field(INPB, "QUAD:IN20:371:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:425:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:425:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:425:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:425:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:425:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:425:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:425:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:425:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:425:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:425:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:425:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:425:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:425:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:425:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:425:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:425:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:425:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:425:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:425:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:425:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:425:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:425:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:425:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:425:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:425:BMAX")
  field(DOL2, "QUAD:IN20:425:BMAX")
  field(DOL3, "QUAD:IN20:425:BMAX")
  field(DOL4, "QUAD:IN20:425:BMIN")
  field(DOL5, "QUAD:IN20:425:BMIN")
  field(DOL6, "QUAD:IN20:425:BMIN")
  field(LNK1, "QUAD:IN20:425:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:425:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:425:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:425:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:425:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:425:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:425:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:425:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:425:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:425:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:425:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:425:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:425:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:425:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:425:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:425:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:425:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:425:EDES NPP MS")
  field(INPB, "QUAD:IN20:425:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:441:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:441:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:441:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:441:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:441:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:441:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:441:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:441:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:441:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:441:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:441:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:441:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:441:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:441:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:441:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:441:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:441:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:441:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:441:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:441:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:441:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:441:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:441:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:441:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:441:BMAX")
  field(DOL2, "QUAD:IN20:441:BMAX")
  field(DOL3, "QUAD:IN20:441:BMAX")
  field(DOL4, "QUAD:IN20:441:BMIN")
  field(DOL5, "QUAD:IN20:441:BMIN")
  field(DOL6, "QUAD:IN20:441:BMIN")
  field(LNK1, "QUAD:IN20:441:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:441:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:441:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:441:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:441:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:441:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:441:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:441:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:441:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:441:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:441:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:441:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:441:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:441:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:441:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:441:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:441:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:441:EDES NPP MS")
  field(INPB, "QUAD:IN20:441:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:511:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:511:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:511:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:511:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:511:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:511:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:511:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:511:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:511:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:511:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:511:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:511:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:511:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:511:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:511:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:511:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:511:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:511:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:511:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:511:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:511:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:511:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:511:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:511:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:511:BMAX")
  field(DOL2, "QUAD:IN20:511:BMAX")
  field(DOL3, "QUAD:IN20:511:BMAX")
  field(DOL4, "QUAD:IN20:511:BMIN")
  field(DOL5, "QUAD:IN20:511:BMIN")
  field(DOL6, "QUAD:IN20:511:BMIN")
  field(LNK1, "QUAD:IN20:511:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:511:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:511:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:511:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:511:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:511:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:511:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:511:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:511:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:511:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:511:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:511:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:511:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:511:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:511:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:511:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:511:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:511:EDES NPP MS")
  field(INPB, "QUAD:IN20:511:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:525:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:525:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:525:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:525:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:525:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:525:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:525:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:525:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:525:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:525:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:525:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:525:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:525:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:525:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:525:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:525:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:525:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:525:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:525:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:525:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:525:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:525:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:525:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:525:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:525:BMAX")
  field(DOL2, "QUAD:IN20:525:BMAX")
  field(DOL3, "QUAD:IN20:525:BMAX")
  field(DOL4, "QUAD:IN20:525:BMIN")
  field(DOL5, "QUAD:IN20:525:BMIN")
  field(DOL6, "QUAD:IN20:525:BMIN")
  field(LNK1, "QUAD:IN20:525:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:525:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:525:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:525:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:525:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:525:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:525:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:525:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:525:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:525:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:525:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:525:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:525:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:525:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:525:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:525:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:525:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:525:EDES NPP MS")
  field(INPB, "QUAD:IN20:525:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:631:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:631:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:631:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:631:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:631:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:631:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:631:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:631:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:631:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:631:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:631:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:631:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:631:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:631:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:631:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:631:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:631:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:631:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:631:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:631:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:631:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:631:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:631:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:631:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:631:BMAX")
  field(DOL2, "QUAD:IN20:631:BMAX")
  field(DOL3, "QUAD:IN20:631:BMAX")
  field(DOL4, "QUAD:IN20:631:BMIN")
  field(DOL5, "QUAD:IN20:631:BMIN")
  field(DOL6, "QUAD:IN20:631:BMIN")
  field(LNK1, "QUAD:IN20:631:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:631:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:631:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:631:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:631:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:631:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:631:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:631:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:631:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:631:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:631:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:631:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:631:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:631:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:631:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:631:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:631:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:631:EDES NPP MS")
  field(INPB, "QUAD:IN20:631:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:651:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:651:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:651:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:651:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:651:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:651:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:651:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:651:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:651:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:651:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:651:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:651:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:651:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:651:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:651:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:651:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:651:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:651:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:651:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:651:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:651:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:651:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:651:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:651:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:651:BMAX")
  field(DOL2, "QUAD:IN20:651:BMAX")
  field(DOL3, "QUAD:IN20:651:BMAX")
  field(DOL4, "QUAD:IN20:651:BMIN")
  field(DOL5, "QUAD:IN20:651:BMIN")
  field(DOL6, "QUAD:IN20:651:BMIN")
  field(LNK1, "QUAD:IN20:651:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:651:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:651:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:651:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:651:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:651:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:651:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:651:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:651:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:651:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:651:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:651:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:651:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:651:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:651:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:651:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:651:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:651:EDES NPP MS")
  field(INPB, "QUAD:IN20:651:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:731:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:731:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:731:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:731:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:731:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:731:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:731:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:731:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:731:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:731:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:731:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:731:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:731:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:731:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:731:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:731:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:731:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:731:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:731:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:731:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:731:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:731:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:731:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:731:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:731:BMAX")
  field(DOL2, "QUAD:IN20:731:BMAX")
  field(DOL3, "QUAD:IN20:731:BMAX")
  field(DOL4, "QUAD:IN20:731:BMIN")
  field(DOL5, "QUAD:IN20:731:BMIN")
  field(DOL6, "QUAD:IN20:731:BMIN")
  field(LNK1, "QUAD:IN20:731:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:731:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:731:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:731:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:731:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:731:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:731:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:731:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:731:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:731:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:731:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:731:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:731:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:731:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:731:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:731:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:731:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:731:EDES NPP MS")
  field(INPB, "QUAD:IN20:731:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:771:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:771:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:771:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:771:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:771:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:771:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:771:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:771:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:771:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:771:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:771:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:771:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:771:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:771:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:771:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:771:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:771:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:771:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:771:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:771:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:771:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:771:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:771:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:771:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:771:BMAX")
  field(DOL2, "QUAD:IN20:771:BMAX")
  field(DOL3, "QUAD:IN20:771:BMAX")
  field(DOL4, "QUAD:IN20:771:BMIN")
  field(DOL5, "QUAD:IN20:771:BMIN")
  field(DOL6, "QUAD:IN20:771:BMIN")
  field(LNK1, "QUAD:IN20:771:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:771:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:771:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:771:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:771:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:771:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:771:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:771:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:771:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:771:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:771:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:771:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:771:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:771:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:771:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:771:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:771:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:771:EDES NPP MS")
  field(INPB, "QUAD:IN20:771:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:781:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:781:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:781:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:781:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:781:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:781:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:781:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:781:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:781:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:781:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:781:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:781:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:781:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:781:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:781:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:781:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:781:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:781:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:781:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:781:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:781:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:781:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:781:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:781:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:781:BMAX")
  field(DOL2, "QUAD:IN20:781:BMAX")
  field(DOL3, "QUAD:IN20:781:BMAX")
  field(DOL4, "QUAD:IN20:781:BMIN")
  field(DOL5, "QUAD:IN20:781:BMIN")
  field(DOL6, "QUAD:IN20:781:BMIN")
  field(LNK1, "QUAD:IN20:781:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:781:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:781:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:781:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:781:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:781:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:781:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:781:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:781:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:781:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:781:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:781:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:781:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:781:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:781:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:781:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:781:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:781:EDES NPP MS")
  field(INPB, "QUAD:IN20:781:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:811:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:811:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:811:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:811:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:811:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:811:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:811:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:811:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:811:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:811:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:811:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:811:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:811:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:811:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:811:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:811:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:811:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:811:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:811:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:811:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:811:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:811:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:811:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:811:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:811:BMAX")
  field(DOL2, "QUAD:IN20:811:BMAX")
  field(DOL3, "QUAD:IN20:811:BMAX")
  field(DOL4, "QUAD:IN20:811:BMIN")
  field(DOL5, "QUAD:IN20:811:BMIN")
  field(DOL6, "QUAD:IN20:811:BMIN")
  field(LNK1, "QUAD:IN20:811:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:811:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:811:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:811:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:811:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:811:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:811:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:811:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:811:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:811:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:811:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:811:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:811:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:811:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:811:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:811:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:811:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:811:EDES NPP MS")
  field(INPB, "QUAD:IN20:811:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:831:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:831:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:831:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:831:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:831:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:831:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:831:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:831:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:831:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:831:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:831:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:831:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:831:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:831:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:831:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:831:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:831:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:831:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:831:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:831:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:831:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:831:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:831:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:831:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:831:BMAX")
  field(DOL2, "QUAD:IN20:831:BMAX")
  field(DOL3, "QUAD:IN20:831:BMAX")
  field(DOL4, "QUAD:IN20:831:BMIN")
  field(DOL5, "QUAD:IN20:831:BMIN")
  field(DOL6, "QUAD:IN20:831:BMIN")
  field(LNK1, "QUAD:IN20:831:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:831:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:831:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:831:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:831:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:831:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:831:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:831:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:831:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:831:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:831:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:831:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:831:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:831:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:831:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:831:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:831:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:831:EDES NPP MS")
  field(INPB, "QUAD:IN20:831:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:941:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:941:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:941:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:941:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:941:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:941:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:941:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:941:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:941:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:941:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:941:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:941:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:941:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:941:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:941:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:941:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:941:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:941:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:941:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:941:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:941:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:941:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:941:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:941:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:941:BMAX")
  field(DOL2, "QUAD:IN20:941:BMAX")
  field(DOL3, "QUAD:IN20:941:BMAX")
  field(DOL4, "QUAD:IN20:941:BMIN")
  field(DOL5, "QUAD:IN20:941:BMIN")
  field(DOL6, "QUAD:IN20:941:BMIN")
  field(LNK1, "QUAD:IN20:941:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:941:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:941:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:941:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:941:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:941:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:941:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:941:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:941:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:941:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:941:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:941:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:941:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:941:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:941:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:941:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:941:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:941:EDES NPP MS")
  field(INPB, "QUAD:IN20:941:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:IN20:961:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "QUAD:IN20:961:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:IN20:961:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:IN20:961:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:IN20:961:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:IN20:961:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:IN20:961:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:IN20:961:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:IN20:961:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:IN20:961:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:IN20:961:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:IN20:961:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:IN20:961:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:IN20:961:EDES.PROC PP")
    field(LNK2, "QUAD:IN20:961:EACT.PROC PP")
    field(LNK3, "QUAD:IN20:961:EERR.DISA PP")
    field(LNK4, "QUAD:IN20:961:ECON.PROC PP")
    field(LNK5, "QUAD:IN20:961:BMAGX.PROC PP")
    field(LNK6, "QUAD:IN20:961:BMAGY.PROC PP")
    field(LNK7, "QUAD:IN20:961:BLEM.PROC PP")
    field(LNK8, "QUAD:IN20:961:BMOD.PROC PP")
    field(LNK9, "QUAD:IN20:961:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:IN20:961:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:IN20:961:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:IN20:961:BMAX")
  field(DOL2, "QUAD:IN20:961:BMAX")
  field(DOL3, "QUAD:IN20:961:BMAX")
  field(DOL4, "QUAD:IN20:961:BMIN")
  field(DOL5, "QUAD:IN20:961:BMIN")
  field(DOL6, "QUAD:IN20:961:BMIN")
  field(LNK1, "QUAD:IN20:961:BMAGX.HOPR")
  field(LNK2, "QUAD:IN20:961:BMAGY.HOPR")
  field(LNK3, "QUAD:IN20:961:BLEM.HOPR")
  field(LNK4, "QUAD:IN20:961:BMAGX.LOPR PP")
  field(LNK5, "QUAD:IN20:961:BMAGY.LOPR PP")
  field(LNK6, "QUAD:IN20:961:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:961:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:IN20:961:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:IN20:961:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:IN20:961:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:IN20:961:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:961:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:961:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:961:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:IN20:961:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:IN20:961:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:IN20:961:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:IN20:961:EDES NPP MS")
  field(INPB, "QUAD:IN20:961:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "SOLN:IN20:111:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "SOLN:IN20:111:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "SOLN:IN20:111:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "SOLN:IN20:111:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "SOLN:IN20:111:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "SOLN:IN20:111:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "SOLN:IN20:111:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "SOLN:IN20:111:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "SOLN:IN20:111:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "SOLN:IN20:111:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "SOLN:IN20:111:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "SOLN:IN20:111:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "SOLN:IN20:111:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "SOLN:IN20:111:EDES.PROC PP")
    field(LNK2, "SOLN:IN20:111:EACT.PROC PP")
    field(LNK3, "SOLN:IN20:111:EERR.DISA PP")
    field(LNK4, "SOLN:IN20:111:ECON.PROC PP")
    field(LNK5, "SOLN:IN20:111:BMAGX.PROC PP")
    field(LNK6, "SOLN:IN20:111:BMAGY.PROC PP")
    field(LNK7, "SOLN:IN20:111:BLEM.PROC PP")
    field(LNK8, "SOLN:IN20:111:BMOD.PROC PP")
    field(LNK9, "SOLN:IN20:111:EDESSAVE.PROC PP")
    field(LNKA, "SOLN:IN20:111:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"SOLN:IN20:111:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "SOLN:IN20:111:BMAX")
  field(DOL2, "SOLN:IN20:111:BMAX")
  field(DOL3, "SOLN:IN20:111:BMAX")
  field(DOL4, "SOLN:IN20:111:BMIN")
  field(DOL5, "SOLN:IN20:111:BMIN")
  field(DOL6, "SOLN:IN20:111:BMIN")
  field(LNK1, "SOLN:IN20:111:BMAGX.HOPR")
  field(LNK2, "SOLN:IN20:111:BMAGY.HOPR")
  field(LNK3, "SOLN:IN20:111:BLEM.HOPR")
  field(LNK4, "SOLN:IN20:111:BMAGX.LOPR PP")
  field(LNK5, "SOLN:IN20:111:BMAGY.LOPR PP")
  field(LNK6, "SOLN:IN20:111:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "SOLN:IN20:111:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "SOLN:IN20:111:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "SOLN:IN20:111:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "SOLN:IN20:111:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "SOLN:IN20:111:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:IN20:111:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:IN20:111:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "SOLN:IN20:111:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:IN20:111:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "SOLN:IN20:111:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "SOLN:IN20:111:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "SOLN:IN20:111:EDES NPP MS")
  field(INPB, "SOLN:IN20:111:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "SOLN:IN20:121:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "SOLN:IN20:121:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "SOLN:IN20:121:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "SOLN:IN20:121:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "SOLN:IN20:121:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "SOLN:IN20:121:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "SOLN:IN20:121:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "SOLN:IN20:121:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "SOLN:IN20:121:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "SOLN:IN20:121:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "SOLN:IN20:121:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "SOLN:IN20:121:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "SOLN:IN20:121:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "SOLN:IN20:121:EDES.PROC PP")
    field(LNK2, "SOLN:IN20:121:EACT.PROC PP")
    field(LNK3, "SOLN:IN20:121:EERR.DISA PP")
    field(LNK4, "SOLN:IN20:121:ECON.PROC PP")
    field(LNK5, "SOLN:IN20:121:BMAGX.PROC PP")
    field(LNK6, "SOLN:IN20:121:BMAGY.PROC PP")
    field(LNK7, "SOLN:IN20:121:BLEM.PROC PP")
    field(LNK8, "SOLN:IN20:121:BMOD.PROC PP")
    field(LNK9, "SOLN:IN20:121:EDESSAVE.PROC PP")
    field(LNKA, "SOLN:IN20:121:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"SOLN:IN20:121:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "SOLN:IN20:121:BMAX")
  field(DOL2, "SOLN:IN20:121:BMAX")
  field(DOL3, "SOLN:IN20:121:BMAX")
  field(DOL4, "SOLN:IN20:121:BMIN")
  field(DOL5, "SOLN:IN20:121:BMIN")
  field(DOL6, "SOLN:IN20:121:BMIN")
  field(LNK1, "SOLN:IN20:121:BMAGX.HOPR")
  field(LNK2, "SOLN:IN20:121:BMAGY.HOPR")
  field(LNK3, "SOLN:IN20:121:BLEM.HOPR")
  field(LNK4, "SOLN:IN20:121:BMAGX.LOPR PP")
  field(LNK5, "SOLN:IN20:121:BMAGY.LOPR PP")
  field(LNK6, "SOLN:IN20:121:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "SOLN:IN20:121:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "SOLN:IN20:121:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "SOLN:IN20:121:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "SOLN:IN20:121:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "SOLN:IN20:121:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:IN20:121:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:IN20:121:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "SOLN:IN20:121:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:IN20:121:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "SOLN:IN20:121:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "SOLN:IN20:121:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "SOLN:IN20:121:EDES NPP MS")
  field(INPB, "SOLN:IN20:121:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "SOLN:IN20:311:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "SOLN:IN20:311:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "SOLN:IN20:311:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "SOLN:IN20:311:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "SOLN:IN20:311:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "SOLN:IN20:311:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "SOLN:IN20:311:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "SOLN:IN20:311:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "SOLN:IN20:311:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "SOLN:IN20:311:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "SOLN:IN20:311:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "SOLN:IN20:311:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "SOLN:IN20:311:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "SOLN:IN20:311:EDES.PROC PP")
    field(LNK2, "SOLN:IN20:311:EACT.PROC PP")
    field(LNK3, "SOLN:IN20:311:EERR.DISA PP")
    field(LNK4, "SOLN:IN20:311:ECON.PROC PP")
    field(LNK5, "SOLN:IN20:311:BMAGX.PROC PP")
    field(LNK6, "SOLN:IN20:311:BMAGY.PROC PP")
    field(LNK7, "SOLN:IN20:311:BLEM.PROC PP")
    field(LNK8, "SOLN:IN20:311:BMOD.PROC PP")
    field(LNK9, "SOLN:IN20:311:EDESSAVE.PROC PP")
    field(LNKA, "SOLN:IN20:311:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"SOLN:IN20:311:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "SOLN:IN20:311:BMAX")
  field(DOL2, "SOLN:IN20:311:BMAX")
  field(DOL3, "SOLN:IN20:311:BMAX")
  field(DOL4, "SOLN:IN20:311:BMIN")
  field(DOL5, "SOLN:IN20:311:BMIN")
  field(DOL6, "SOLN:IN20:311:BMIN")
  field(LNK1, "SOLN:IN20:311:BMAGX.HOPR")
  field(LNK2, "SOLN:IN20:311:BMAGY.HOPR")
  field(LNK3, "SOLN:IN20:311:BLEM.HOPR")
  field(LNK4, "SOLN:IN20:311:BMAGX.LOPR PP")
  field(LNK5, "SOLN:IN20:311:BMAGY.LOPR PP")
  field(LNK6, "SOLN:IN20:311:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "SOLN:IN20:311:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "SOLN:IN20:311:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "SOLN:IN20:311:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "SOLN:IN20:311:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "SOLN:IN20:311:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:IN20:311:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:IN20:311:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "SOLN:IN20:311:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:IN20:311:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "SOLN:IN20:311:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "SOLN:IN20:311:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "SOLN:IN20:311:EDES NPP MS")
  field(INPB, "SOLN:IN20:311:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:IN20:121:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "XCOR:IN20:121:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:IN20:121:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:IN20:121:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:IN20:121:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:IN20:121:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:IN20:121:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:IN20:121:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:IN20:121:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:IN20:121:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:IN20:121:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:IN20:121:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:IN20:121:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:IN20:121:EDES.PROC PP")
    field(LNK2, "XCOR:IN20:121:EACT.PROC PP")
    field(LNK3, "XCOR:IN20:121:EERR.DISA PP")
    field(LNK4, "XCOR:IN20:121:ECON.PROC PP")
    field(LNK5, "XCOR:IN20:121:BMAGX.PROC PP")
    field(LNK6, "XCOR:IN20:121:BMAGY.PROC PP")
    field(LNK7, "XCOR:IN20:121:BLEM.PROC PP")
    field(LNK8, "XCOR:IN20:121:BMOD.PROC PP")
    field(LNK9, "XCOR:IN20:121:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:IN20:121:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:IN20:121:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:IN20:121:BMAX")
  field(DOL2, "XCOR:IN20:121:BMAX")
  field(DOL3, "XCOR:IN20:121:BMAX")
  field(DOL4, "XCOR:IN20:121:BMIN")
  field(DOL5, "XCOR:IN20:121:BMIN")
  field(DOL6, "XCOR:IN20:121:BMIN")
  field(LNK1, "XCOR:IN20:121:BMAGX.HOPR")
  field(LNK2, "XCOR:IN20:121:BMAGY.HOPR")
  field(LNK3, "XCOR:IN20:121:BLEM.HOPR")
  field(LNK4, "XCOR:IN20:121:BMAGX.LOPR PP")
  field(LNK5, "XCOR:IN20:121:BMAGY.LOPR PP")
  field(LNK6, "XCOR:IN20:121:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:121:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:121:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:IN20:121:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:IN20:121:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:IN20:121:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:121:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:121:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:121:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:121:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:121:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:IN20:121:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:IN20:121:EDES NPP MS")
  field(INPB, "XCOR:IN20:121:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:IN20:221:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "XCOR:IN20:221:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:IN20:221:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:IN20:221:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:IN20:221:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:IN20:221:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:IN20:221:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:IN20:221:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:IN20:221:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:IN20:221:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:IN20:221:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:IN20:221:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:IN20:221:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:IN20:221:EDES.PROC PP")
    field(LNK2, "XCOR:IN20:221:EACT.PROC PP")
    field(LNK3, "XCOR:IN20:221:EERR.DISA PP")
    field(LNK4, "XCOR:IN20:221:ECON.PROC PP")
    field(LNK5, "XCOR:IN20:221:BMAGX.PROC PP")
    field(LNK6, "XCOR:IN20:221:BMAGY.PROC PP")
    field(LNK7, "XCOR:IN20:221:BLEM.PROC PP")
    field(LNK8, "XCOR:IN20:221:BMOD.PROC PP")
    field(LNK9, "XCOR:IN20:221:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:IN20:221:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:IN20:221:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:IN20:221:BMAX")
  field(DOL2, "XCOR:IN20:221:BMAX")
  field(DOL3, "XCOR:IN20:221:BMAX")
  field(DOL4, "XCOR:IN20:221:BMIN")
  field(DOL5, "XCOR:IN20:221:BMIN")
  field(DOL6, "XCOR:IN20:221:BMIN")
  field(LNK1, "XCOR:IN20:221:BMAGX.HOPR")
  field(LNK2, "XCOR:IN20:221:BMAGY.HOPR")
  field(LNK3, "XCOR:IN20:221:BLEM.HOPR")
  field(LNK4, "XCOR:IN20:221:BMAGX.LOPR PP")
  field(LNK5, "XCOR:IN20:221:BMAGY.LOPR PP")
  field(LNK6, "XCOR:IN20:221:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:221:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:221:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:IN20:221:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:IN20:221:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:IN20:221:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:221:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:221:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:221:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:221:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:221:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:IN20:221:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:IN20:221:EDES NPP MS")
  field(INPB, "XCOR:IN20:221:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:IN20:311:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "XCOR:IN20:311:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:IN20:311:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:IN20:311:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:IN20:311:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:IN20:311:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:IN20:311:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:IN20:311:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:IN20:311:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:IN20:311:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:IN20:311:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:IN20:311:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:IN20:311:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:IN20:311:EDES.PROC PP")
    field(LNK2, "XCOR:IN20:311:EACT.PROC PP")
    field(LNK3, "XCOR:IN20:311:EERR.DISA PP")
    field(LNK4, "XCOR:IN20:311:ECON.PROC PP")
    field(LNK5, "XCOR:IN20:311:BMAGX.PROC PP")
    field(LNK6, "XCOR:IN20:311:BMAGY.PROC PP")
    field(LNK7, "XCOR:IN20:311:BLEM.PROC PP")
    field(LNK8, "XCOR:IN20:311:BMOD.PROC PP")
    field(LNK9, "XCOR:IN20:311:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:IN20:311:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:IN20:311:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:IN20:311:BMAX")
  field(DOL2, "XCOR:IN20:311:BMAX")
  field(DOL3, "XCOR:IN20:311:BMAX")
  field(DOL4, "XCOR:IN20:311:BMIN")
  field(DOL5, "XCOR:IN20:311:BMIN")
  field(DOL6, "XCOR:IN20:311:BMIN")
  field(LNK1, "XCOR:IN20:311:BMAGX.HOPR")
  field(LNK2, "XCOR:IN20:311:BMAGY.HOPR")
  field(LNK3, "XCOR:IN20:311:BLEM.HOPR")
  field(LNK4, "XCOR:IN20:311:BMAGX.LOPR PP")
  field(LNK5, "XCOR:IN20:311:BMAGY.LOPR PP")
  field(LNK6, "XCOR:IN20:311:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:311:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:311:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:IN20:311:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:IN20:311:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:IN20:311:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:311:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:311:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:311:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:311:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:311:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:IN20:311:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:IN20:311:EDES NPP MS")
  field(INPB, "XCOR:IN20:311:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:IN20:341:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "XCOR:IN20:341:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:IN20:341:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:IN20:341:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:IN20:341:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:IN20:341:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:IN20:341:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:IN20:341:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:IN20:341:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:IN20:341:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:IN20:341:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:IN20:341:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:IN20:341:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:IN20:341:EDES.PROC PP")
    field(LNK2, "XCOR:IN20:341:EACT.PROC PP")
    field(LNK3, "XCOR:IN20:341:EERR.DISA PP")
    field(LNK4, "XCOR:IN20:341:ECON.PROC PP")
    field(LNK5, "XCOR:IN20:341:BMAGX.PROC PP")
    field(LNK6, "XCOR:IN20:341:BMAGY.PROC PP")
    field(LNK7, "XCOR:IN20:341:BLEM.PROC PP")
    field(LNK8, "XCOR:IN20:341:BMOD.PROC PP")
    field(LNK9, "XCOR:IN20:341:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:IN20:341:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:IN20:341:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:IN20:341:BMAX")
  field(DOL2, "XCOR:IN20:341:BMAX")
  field(DOL3, "XCOR:IN20:341:BMAX")
  field(DOL4, "XCOR:IN20:341:BMIN")
  field(DOL5, "XCOR:IN20:341:BMIN")
  field(DOL6, "XCOR:IN20:341:BMIN")
  field(LNK1, "XCOR:IN20:341:BMAGX.HOPR")
  field(LNK2, "XCOR:IN20:341:BMAGY.HOPR")
  field(LNK3, "XCOR:IN20:341:BLEM.HOPR")
  field(LNK4, "XCOR:IN20:341:BMAGX.LOPR PP")
  field(LNK5, "XCOR:IN20:341:BMAGY.LOPR PP")
  field(LNK6, "XCOR:IN20:341:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:341:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:341:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:IN20:341:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:IN20:341:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:IN20:341:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:341:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:341:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:341:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:341:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:341:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:IN20:341:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:IN20:341:EDES NPP MS")
  field(INPB, "XCOR:IN20:341:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:IN20:381:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "XCOR:IN20:381:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:IN20:381:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:IN20:381:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:IN20:381:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:IN20:381:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:IN20:381:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:IN20:381:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:IN20:381:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:IN20:381:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:IN20:381:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:IN20:381:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:IN20:381:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:IN20:381:EDES.PROC PP")
    field(LNK2, "XCOR:IN20:381:EACT.PROC PP")
    field(LNK3, "XCOR:IN20:381:EERR.DISA PP")
    field(LNK4, "XCOR:IN20:381:ECON.PROC PP")
    field(LNK5, "XCOR:IN20:381:BMAGX.PROC PP")
    field(LNK6, "XCOR:IN20:381:BMAGY.PROC PP")
    field(LNK7, "XCOR:IN20:381:BLEM.PROC PP")
    field(LNK8, "XCOR:IN20:381:BMOD.PROC PP")
    field(LNK9, "XCOR:IN20:381:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:IN20:381:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:IN20:381:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:IN20:381:BMAX")
  field(DOL2, "XCOR:IN20:381:BMAX")
  field(DOL3, "XCOR:IN20:381:BMAX")
  field(DOL4, "XCOR:IN20:381:BMIN")
  field(DOL5, "XCOR:IN20:381:BMIN")
  field(DOL6, "XCOR:IN20:381:BMIN")
  field(LNK1, "XCOR:IN20:381:BMAGX.HOPR")
  field(LNK2, "XCOR:IN20:381:BMAGY.HOPR")
  field(LNK3, "XCOR:IN20:381:BLEM.HOPR")
  field(LNK4, "XCOR:IN20:381:BMAGX.LOPR PP")
  field(LNK5, "XCOR:IN20:381:BMAGY.LOPR PP")
  field(LNK6, "XCOR:IN20:381:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:381:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:381:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:IN20:381:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:IN20:381:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:IN20:381:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:381:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:381:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:381:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:381:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:381:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:IN20:381:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:IN20:381:EDES NPP MS")
  field(INPB, "XCOR:IN20:381:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:IN20:411:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "XCOR:IN20:411:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:IN20:411:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:IN20:411:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:IN20:411:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:IN20:411:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:IN20:411:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:IN20:411:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:IN20:411:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:IN20:411:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:IN20:411:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:IN20:411:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:IN20:411:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:IN20:411:EDES.PROC PP")
    field(LNK2, "XCOR:IN20:411:EACT.PROC PP")
    field(LNK3, "XCOR:IN20:411:EERR.DISA PP")
    field(LNK4, "XCOR:IN20:411:ECON.PROC PP")
    field(LNK5, "XCOR:IN20:411:BMAGX.PROC PP")
    field(LNK6, "XCOR:IN20:411:BMAGY.PROC PP")
    field(LNK7, "XCOR:IN20:411:BLEM.PROC PP")
    field(LNK8, "XCOR:IN20:411:BMOD.PROC PP")
    field(LNK9, "XCOR:IN20:411:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:IN20:411:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:IN20:411:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:IN20:411:BMAX")
  field(DOL2, "XCOR:IN20:411:BMAX")
  field(DOL3, "XCOR:IN20:411:BMAX")
  field(DOL4, "XCOR:IN20:411:BMIN")
  field(DOL5, "XCOR:IN20:411:BMIN")
  field(DOL6, "XCOR:IN20:411:BMIN")
  field(LNK1, "XCOR:IN20:411:BMAGX.HOPR")
  field(LNK2, "XCOR:IN20:411:BMAGY.HOPR")
  field(LNK3, "XCOR:IN20:411:BLEM.HOPR")
  field(LNK4, "XCOR:IN20:411:BMAGX.LOPR PP")
  field(LNK5, "XCOR:IN20:411:BMAGY.LOPR PP")
  field(LNK6, "XCOR:IN20:411:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:411:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:411:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:IN20:411:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:IN20:411:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:IN20:411:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:411:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:411:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:411:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:411:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:411:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:IN20:411:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:IN20:411:EDES NPP MS")
  field(INPB, "XCOR:IN20:411:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:IN20:491:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "XCOR:IN20:491:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:IN20:491:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:IN20:491:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:IN20:491:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:IN20:491:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:IN20:491:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:IN20:491:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:IN20:491:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:IN20:491:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:IN20:491:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:IN20:491:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:IN20:491:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:IN20:491:EDES.PROC PP")
    field(LNK2, "XCOR:IN20:491:EACT.PROC PP")
    field(LNK3, "XCOR:IN20:491:EERR.DISA PP")
    field(LNK4, "XCOR:IN20:491:ECON.PROC PP")
    field(LNK5, "XCOR:IN20:491:BMAGX.PROC PP")
    field(LNK6, "XCOR:IN20:491:BMAGY.PROC PP")
    field(LNK7, "XCOR:IN20:491:BLEM.PROC PP")
    field(LNK8, "XCOR:IN20:491:BMOD.PROC PP")
    field(LNK9, "XCOR:IN20:491:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:IN20:491:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:IN20:491:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:IN20:491:BMAX")
  field(DOL2, "XCOR:IN20:491:BMAX")
  field(DOL3, "XCOR:IN20:491:BMAX")
  field(DOL4, "XCOR:IN20:491:BMIN")
  field(DOL5, "XCOR:IN20:491:BMIN")
  field(DOL6, "XCOR:IN20:491:BMIN")
  field(LNK1, "XCOR:IN20:491:BMAGX.HOPR")
  field(LNK2, "XCOR:IN20:491:BMAGY.HOPR")
  field(LNK3, "XCOR:IN20:491:BLEM.HOPR")
  field(LNK4, "XCOR:IN20:491:BMAGX.LOPR PP")
  field(LNK5, "XCOR:IN20:491:BMAGY.LOPR PP")
  field(LNK6, "XCOR:IN20:491:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:491:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:491:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:IN20:491:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:IN20:491:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:IN20:491:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:491:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:491:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:491:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:491:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:491:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:IN20:491:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:IN20:491:EDES NPP MS")
  field(INPB, "XCOR:IN20:491:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:IN20:521:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "XCOR:IN20:521:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:IN20:521:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:IN20:521:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:IN20:521:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:IN20:521:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:IN20:521:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:IN20:521:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:IN20:521:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:IN20:521:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:IN20:521:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:IN20:521:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:IN20:521:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:IN20:521:EDES.PROC PP")
    field(LNK2, "XCOR:IN20:521:EACT.PROC PP")
    field(LNK3, "XCOR:IN20:521:EERR.DISA PP")
    field(LNK4, "XCOR:IN20:521:ECON.PROC PP")
    field(LNK5, "XCOR:IN20:521:BMAGX.PROC PP")
    field(LNK6, "XCOR:IN20:521:BMAGY.PROC PP")
    field(LNK7, "XCOR:IN20:521:BLEM.PROC PP")
    field(LNK8, "XCOR:IN20:521:BMOD.PROC PP")
    field(LNK9, "XCOR:IN20:521:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:IN20:521:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:IN20:521:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:IN20:521:BMAX")
  field(DOL2, "XCOR:IN20:521:BMAX")
  field(DOL3, "XCOR:IN20:521:BMAX")
  field(DOL4, "XCOR:IN20:521:BMIN")
  field(DOL5, "XCOR:IN20:521:BMIN")
  field(DOL6, "XCOR:IN20:521:BMIN")
  field(LNK1, "XCOR:IN20:521:BMAGX.HOPR")
  field(LNK2, "XCOR:IN20:521:BMAGY.HOPR")
  field(LNK3, "XCOR:IN20:521:BLEM.HOPR")
  field(LNK4, "XCOR:IN20:521:BMAGX.LOPR PP")
  field(LNK5, "XCOR:IN20:521:BMAGY.LOPR PP")
  field(LNK6, "XCOR:IN20:521:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:521:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:521:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:IN20:521:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:IN20:521:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:IN20:521:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:521:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:521:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:521:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:521:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:521:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:IN20:521:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:IN20:521:EDES NPP MS")
  field(INPB, "XCOR:IN20:521:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:IN20:641:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "XCOR:IN20:641:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:IN20:641:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:IN20:641:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:IN20:641:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:IN20:641:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:IN20:641:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:IN20:641:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:IN20:641:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:IN20:641:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:IN20:641:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:IN20:641:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:IN20:641:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:IN20:641:EDES.PROC PP")
    field(LNK2, "XCOR:IN20:641:EACT.PROC PP")
    field(LNK3, "XCOR:IN20:641:EERR.DISA PP")
    field(LNK4, "XCOR:IN20:641:ECON.PROC PP")
    field(LNK5, "XCOR:IN20:641:BMAGX.PROC PP")
    field(LNK6, "XCOR:IN20:641:BMAGY.PROC PP")
    field(LNK7, "XCOR:IN20:641:BLEM.PROC PP")
    field(LNK8, "XCOR:IN20:641:BMOD.PROC PP")
    field(LNK9, "XCOR:IN20:641:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:IN20:641:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:IN20:641:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:IN20:641:BMAX")
  field(DOL2, "XCOR:IN20:641:BMAX")
  field(DOL3, "XCOR:IN20:641:BMAX")
  field(DOL4, "XCOR:IN20:641:BMIN")
  field(DOL5, "XCOR:IN20:641:BMIN")
  field(DOL6, "XCOR:IN20:641:BMIN")
  field(LNK1, "XCOR:IN20:641:BMAGX.HOPR")
  field(LNK2, "XCOR:IN20:641:BMAGY.HOPR")
  field(LNK3, "XCOR:IN20:641:BLEM.HOPR")
  field(LNK4, "XCOR:IN20:641:BMAGX.LOPR PP")
  field(LNK5, "XCOR:IN20:641:BMAGY.LOPR PP")
  field(LNK6, "XCOR:IN20:641:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:641:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:641:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:IN20:641:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:IN20:641:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:IN20:641:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:641:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:641:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:641:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:641:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:641:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:IN20:641:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:IN20:641:EDES NPP MS")
  field(INPB, "XCOR:IN20:641:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:IN20:721:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "XCOR:IN20:721:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:IN20:721:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:IN20:721:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:IN20:721:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:IN20:721:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:IN20:721:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:IN20:721:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:IN20:721:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:IN20:721:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:IN20:721:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:IN20:721:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:IN20:721:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:IN20:721:EDES.PROC PP")
    field(LNK2, "XCOR:IN20:721:EACT.PROC PP")
    field(LNK3, "XCOR:IN20:721:EERR.DISA PP")
    field(LNK4, "XCOR:IN20:721:ECON.PROC PP")
    field(LNK5, "XCOR:IN20:721:BMAGX.PROC PP")
    field(LNK6, "XCOR:IN20:721:BMAGY.PROC PP")
    field(LNK7, "XCOR:IN20:721:BLEM.PROC PP")
    field(LNK8, "XCOR:IN20:721:BMOD.PROC PP")
    field(LNK9, "XCOR:IN20:721:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:IN20:721:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:IN20:721:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:IN20:721:BMAX")
  field(DOL2, "XCOR:IN20:721:BMAX")
  field(DOL3, "XCOR:IN20:721:BMAX")
  field(DOL4, "XCOR:IN20:721:BMIN")
  field(DOL5, "XCOR:IN20:721:BMIN")
  field(DOL6, "XCOR:IN20:721:BMIN")
  field(LNK1, "XCOR:IN20:721:BMAGX.HOPR")
  field(LNK2, "XCOR:IN20:721:BMAGY.HOPR")
  field(LNK3, "XCOR:IN20:721:BLEM.HOPR")
  field(LNK4, "XCOR:IN20:721:BMAGX.LOPR PP")
  field(LNK5, "XCOR:IN20:721:BMAGY.LOPR PP")
  field(LNK6, "XCOR:IN20:721:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:721:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:721:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:IN20:721:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:IN20:721:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:IN20:721:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:721:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:721:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:721:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:721:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:721:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:IN20:721:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:IN20:721:EDES NPP MS")
  field(INPB, "XCOR:IN20:721:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:IN20:761:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "XCOR:IN20:761:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:IN20:761:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:IN20:761:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:IN20:761:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:IN20:761:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:IN20:761:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:IN20:761:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:IN20:761:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:IN20:761:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:IN20:761:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:IN20:761:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:IN20:761:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:IN20:761:EDES.PROC PP")
    field(LNK2, "XCOR:IN20:761:EACT.PROC PP")
    field(LNK3, "XCOR:IN20:761:EERR.DISA PP")
    field(LNK4, "XCOR:IN20:761:ECON.PROC PP")
    field(LNK5, "XCOR:IN20:761:BMAGX.PROC PP")
    field(LNK6, "XCOR:IN20:761:BMAGY.PROC PP")
    field(LNK7, "XCOR:IN20:761:BLEM.PROC PP")
    field(LNK8, "XCOR:IN20:761:BMOD.PROC PP")
    field(LNK9, "XCOR:IN20:761:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:IN20:761:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:IN20:761:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:IN20:761:BMAX")
  field(DOL2, "XCOR:IN20:761:BMAX")
  field(DOL3, "XCOR:IN20:761:BMAX")
  field(DOL4, "XCOR:IN20:761:BMIN")
  field(DOL5, "XCOR:IN20:761:BMIN")
  field(DOL6, "XCOR:IN20:761:BMIN")
  field(LNK1, "XCOR:IN20:761:BMAGX.HOPR")
  field(LNK2, "XCOR:IN20:761:BMAGY.HOPR")
  field(LNK3, "XCOR:IN20:761:BLEM.HOPR")
  field(LNK4, "XCOR:IN20:761:BMAGX.LOPR PP")
  field(LNK5, "XCOR:IN20:761:BMAGY.LOPR PP")
  field(LNK6, "XCOR:IN20:761:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:761:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:761:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:IN20:761:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:IN20:761:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:IN20:761:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:761:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:761:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:761:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:761:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:761:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:IN20:761:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:IN20:761:EDES NPP MS")
  field(INPB, "XCOR:IN20:761:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:IN20:811:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "XCOR:IN20:811:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:IN20:811:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:IN20:811:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:IN20:811:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:IN20:811:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:IN20:811:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:IN20:811:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:IN20:811:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:IN20:811:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:IN20:811:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:IN20:811:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:IN20:811:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:IN20:811:EDES.PROC PP")
    field(LNK2, "XCOR:IN20:811:EACT.PROC PP")
    field(LNK3, "XCOR:IN20:811:EERR.DISA PP")
    field(LNK4, "XCOR:IN20:811:ECON.PROC PP")
    field(LNK5, "XCOR:IN20:811:BMAGX.PROC PP")
    field(LNK6, "XCOR:IN20:811:BMAGY.PROC PP")
    field(LNK7, "XCOR:IN20:811:BLEM.PROC PP")
    field(LNK8, "XCOR:IN20:811:BMOD.PROC PP")
    field(LNK9, "XCOR:IN20:811:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:IN20:811:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:IN20:811:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:IN20:811:BMAX")
  field(DOL2, "XCOR:IN20:811:BMAX")
  field(DOL3, "XCOR:IN20:811:BMAX")
  field(DOL4, "XCOR:IN20:811:BMIN")
  field(DOL5, "XCOR:IN20:811:BMIN")
  field(DOL6, "XCOR:IN20:811:BMIN")
  field(LNK1, "XCOR:IN20:811:BMAGX.HOPR")
  field(LNK2, "XCOR:IN20:811:BMAGY.HOPR")
  field(LNK3, "XCOR:IN20:811:BLEM.HOPR")
  field(LNK4, "XCOR:IN20:811:BMAGX.LOPR PP")
  field(LNK5, "XCOR:IN20:811:BMAGY.LOPR PP")
  field(LNK6, "XCOR:IN20:811:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:811:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:811:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:IN20:811:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:IN20:811:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:IN20:811:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:811:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:811:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:811:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:811:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:811:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:IN20:811:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:IN20:811:EDES NPP MS")
  field(INPB, "XCOR:IN20:811:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:IN20:831:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "XCOR:IN20:831:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:IN20:831:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:IN20:831:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:IN20:831:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:IN20:831:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:IN20:831:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:IN20:831:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:IN20:831:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:IN20:831:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:IN20:831:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:IN20:831:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:IN20:831:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:IN20:831:EDES.PROC PP")
    field(LNK2, "XCOR:IN20:831:EACT.PROC PP")
    field(LNK3, "XCOR:IN20:831:EERR.DISA PP")
    field(LNK4, "XCOR:IN20:831:ECON.PROC PP")
    field(LNK5, "XCOR:IN20:831:BMAGX.PROC PP")
    field(LNK6, "XCOR:IN20:831:BMAGY.PROC PP")
    field(LNK7, "XCOR:IN20:831:BLEM.PROC PP")
    field(LNK8, "XCOR:IN20:831:BMOD.PROC PP")
    field(LNK9, "XCOR:IN20:831:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:IN20:831:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:IN20:831:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:IN20:831:BMAX")
  field(DOL2, "XCOR:IN20:831:BMAX")
  field(DOL3, "XCOR:IN20:831:BMAX")
  field(DOL4, "XCOR:IN20:831:BMIN")
  field(DOL5, "XCOR:IN20:831:BMIN")
  field(DOL6, "XCOR:IN20:831:BMIN")
  field(LNK1, "XCOR:IN20:831:BMAGX.HOPR")
  field(LNK2, "XCOR:IN20:831:BMAGY.HOPR")
  field(LNK3, "XCOR:IN20:831:BLEM.HOPR")
  field(LNK4, "XCOR:IN20:831:BMAGX.LOPR PP")
  field(LNK5, "XCOR:IN20:831:BMAGY.LOPR PP")
  field(LNK6, "XCOR:IN20:831:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:831:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:831:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:IN20:831:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:IN20:831:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:IN20:831:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:831:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:831:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:831:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:831:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:831:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:IN20:831:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:IN20:831:EDES NPP MS")
  field(INPB, "XCOR:IN20:831:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:IN20:911:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "XCOR:IN20:911:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:IN20:911:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:IN20:911:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:IN20:911:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:IN20:911:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:IN20:911:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:IN20:911:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:IN20:911:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:IN20:911:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:IN20:911:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:IN20:911:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:IN20:911:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:IN20:911:EDES.PROC PP")
    field(LNK2, "XCOR:IN20:911:EACT.PROC PP")
    field(LNK3, "XCOR:IN20:911:EERR.DISA PP")
    field(LNK4, "XCOR:IN20:911:ECON.PROC PP")
    field(LNK5, "XCOR:IN20:911:BMAGX.PROC PP")
    field(LNK6, "XCOR:IN20:911:BMAGY.PROC PP")
    field(LNK7, "XCOR:IN20:911:BLEM.PROC PP")
    field(LNK8, "XCOR:IN20:911:BMOD.PROC PP")
    field(LNK9, "XCOR:IN20:911:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:IN20:911:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:IN20:911:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:IN20:911:BMAX")
  field(DOL2, "XCOR:IN20:911:BMAX")
  field(DOL3, "XCOR:IN20:911:BMAX")
  field(DOL4, "XCOR:IN20:911:BMIN")
  field(DOL5, "XCOR:IN20:911:BMIN")
  field(DOL6, "XCOR:IN20:911:BMIN")
  field(LNK1, "XCOR:IN20:911:BMAGX.HOPR")
  field(LNK2, "XCOR:IN20:911:BMAGY.HOPR")
  field(LNK3, "XCOR:IN20:911:BLEM.HOPR")
  field(LNK4, "XCOR:IN20:911:BMAGX.LOPR PP")
  field(LNK5, "XCOR:IN20:911:BMAGY.LOPR PP")
  field(LNK6, "XCOR:IN20:911:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:911:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:911:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:IN20:911:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:IN20:911:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:IN20:911:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:911:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:911:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:911:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:911:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:911:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:IN20:911:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:IN20:911:EDES NPP MS")
  field(INPB, "XCOR:IN20:911:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:IN20:951:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "XCOR:IN20:951:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:IN20:951:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:IN20:951:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:IN20:951:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:IN20:951:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:IN20:951:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:IN20:951:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:IN20:951:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:IN20:951:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:IN20:951:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:IN20:951:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:IN20:951:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:IN20:951:EDES.PROC PP")
    field(LNK2, "XCOR:IN20:951:EACT.PROC PP")
    field(LNK3, "XCOR:IN20:951:EERR.DISA PP")
    field(LNK4, "XCOR:IN20:951:ECON.PROC PP")
    field(LNK5, "XCOR:IN20:951:BMAGX.PROC PP")
    field(LNK6, "XCOR:IN20:951:BMAGY.PROC PP")
    field(LNK7, "XCOR:IN20:951:BLEM.PROC PP")
    field(LNK8, "XCOR:IN20:951:BMOD.PROC PP")
    field(LNK9, "XCOR:IN20:951:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:IN20:951:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:IN20:951:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:IN20:951:BMAX")
  field(DOL2, "XCOR:IN20:951:BMAX")
  field(DOL3, "XCOR:IN20:951:BMAX")
  field(DOL4, "XCOR:IN20:951:BMIN")
  field(DOL5, "XCOR:IN20:951:BMIN")
  field(DOL6, "XCOR:IN20:951:BMIN")
  field(LNK1, "XCOR:IN20:951:BMAGX.HOPR")
  field(LNK2, "XCOR:IN20:951:BMAGY.HOPR")
  field(LNK3, "XCOR:IN20:951:BLEM.HOPR")
  field(LNK4, "XCOR:IN20:951:BMAGX.LOPR PP")
  field(LNK5, "XCOR:IN20:951:BMAGY.LOPR PP")
  field(LNK6, "XCOR:IN20:951:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:951:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:IN20:951:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:IN20:951:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:IN20:951:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:IN20:951:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:951:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:951:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:951:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:IN20:951:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:IN20:951:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:IN20:951:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:IN20:951:EDES NPP MS")
  field(INPB, "XCOR:IN20:951:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:IN20:122:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "YCOR:IN20:122:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:IN20:122:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:IN20:122:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:IN20:122:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:IN20:122:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:IN20:122:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:IN20:122:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:IN20:122:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:IN20:122:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:IN20:122:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:IN20:122:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:IN20:122:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:IN20:122:EDES.PROC PP")
    field(LNK2, "YCOR:IN20:122:EACT.PROC PP")
    field(LNK3, "YCOR:IN20:122:EERR.DISA PP")
    field(LNK4, "YCOR:IN20:122:ECON.PROC PP")
    field(LNK5, "YCOR:IN20:122:BMAGX.PROC PP")
    field(LNK6, "YCOR:IN20:122:BMAGY.PROC PP")
    field(LNK7, "YCOR:IN20:122:BLEM.PROC PP")
    field(LNK8, "YCOR:IN20:122:BMOD.PROC PP")
    field(LNK9, "YCOR:IN20:122:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:IN20:122:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:IN20:122:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:IN20:122:BMAX")
  field(DOL2, "YCOR:IN20:122:BMAX")
  field(DOL3, "YCOR:IN20:122:BMAX")
  field(DOL4, "YCOR:IN20:122:BMIN")
  field(DOL5, "YCOR:IN20:122:BMIN")
  field(DOL6, "YCOR:IN20:122:BMIN")
  field(LNK1, "YCOR:IN20:122:BMAGX.HOPR")
  field(LNK2, "YCOR:IN20:122:BMAGY.HOPR")
  field(LNK3, "YCOR:IN20:122:BLEM.HOPR")
  field(LNK4, "YCOR:IN20:122:BMAGX.LOPR PP")
  field(LNK5, "YCOR:IN20:122:BMAGY.LOPR PP")
  field(LNK6, "YCOR:IN20:122:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:122:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:122:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:IN20:122:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:IN20:122:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:IN20:122:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:122:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:122:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:122:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:122:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:122:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:IN20:122:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:IN20:122:EDES NPP MS")
  field(INPB, "YCOR:IN20:122:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:IN20:222:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "YCOR:IN20:222:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:IN20:222:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:IN20:222:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:IN20:222:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:IN20:222:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:IN20:222:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:IN20:222:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:IN20:222:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:IN20:222:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:IN20:222:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:IN20:222:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:IN20:222:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:IN20:222:EDES.PROC PP")
    field(LNK2, "YCOR:IN20:222:EACT.PROC PP")
    field(LNK3, "YCOR:IN20:222:EERR.DISA PP")
    field(LNK4, "YCOR:IN20:222:ECON.PROC PP")
    field(LNK5, "YCOR:IN20:222:BMAGX.PROC PP")
    field(LNK6, "YCOR:IN20:222:BMAGY.PROC PP")
    field(LNK7, "YCOR:IN20:222:BLEM.PROC PP")
    field(LNK8, "YCOR:IN20:222:BMOD.PROC PP")
    field(LNK9, "YCOR:IN20:222:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:IN20:222:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:IN20:222:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:IN20:222:BMAX")
  field(DOL2, "YCOR:IN20:222:BMAX")
  field(DOL3, "YCOR:IN20:222:BMAX")
  field(DOL4, "YCOR:IN20:222:BMIN")
  field(DOL5, "YCOR:IN20:222:BMIN")
  field(DOL6, "YCOR:IN20:222:BMIN")
  field(LNK1, "YCOR:IN20:222:BMAGX.HOPR")
  field(LNK2, "YCOR:IN20:222:BMAGY.HOPR")
  field(LNK3, "YCOR:IN20:222:BLEM.HOPR")
  field(LNK4, "YCOR:IN20:222:BMAGX.LOPR PP")
  field(LNK5, "YCOR:IN20:222:BMAGY.LOPR PP")
  field(LNK6, "YCOR:IN20:222:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:222:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:222:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:IN20:222:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:IN20:222:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:IN20:222:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:222:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:222:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:222:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:222:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:222:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:IN20:222:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:IN20:222:EDES NPP MS")
  field(INPB, "YCOR:IN20:222:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:IN20:312:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "YCOR:IN20:312:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:IN20:312:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:IN20:312:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:IN20:312:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:IN20:312:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:IN20:312:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:IN20:312:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:IN20:312:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:IN20:312:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:IN20:312:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:IN20:312:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:IN20:312:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:IN20:312:EDES.PROC PP")
    field(LNK2, "YCOR:IN20:312:EACT.PROC PP")
    field(LNK3, "YCOR:IN20:312:EERR.DISA PP")
    field(LNK4, "YCOR:IN20:312:ECON.PROC PP")
    field(LNK5, "YCOR:IN20:312:BMAGX.PROC PP")
    field(LNK6, "YCOR:IN20:312:BMAGY.PROC PP")
    field(LNK7, "YCOR:IN20:312:BLEM.PROC PP")
    field(LNK8, "YCOR:IN20:312:BMOD.PROC PP")
    field(LNK9, "YCOR:IN20:312:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:IN20:312:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:IN20:312:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:IN20:312:BMAX")
  field(DOL2, "YCOR:IN20:312:BMAX")
  field(DOL3, "YCOR:IN20:312:BMAX")
  field(DOL4, "YCOR:IN20:312:BMIN")
  field(DOL5, "YCOR:IN20:312:BMIN")
  field(DOL6, "YCOR:IN20:312:BMIN")
  field(LNK1, "YCOR:IN20:312:BMAGX.HOPR")
  field(LNK2, "YCOR:IN20:312:BMAGY.HOPR")
  field(LNK3, "YCOR:IN20:312:BLEM.HOPR")
  field(LNK4, "YCOR:IN20:312:BMAGX.LOPR PP")
  field(LNK5, "YCOR:IN20:312:BMAGY.LOPR PP")
  field(LNK6, "YCOR:IN20:312:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:312:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:312:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:IN20:312:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:IN20:312:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:IN20:312:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:312:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:312:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:312:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:312:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:312:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:IN20:312:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:IN20:312:EDES NPP MS")
  field(INPB, "YCOR:IN20:312:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:IN20:342:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "YCOR:IN20:342:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:IN20:342:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:IN20:342:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:IN20:342:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:IN20:342:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:IN20:342:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:IN20:342:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:IN20:342:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:IN20:342:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:IN20:342:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:IN20:342:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:IN20:342:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:IN20:342:EDES.PROC PP")
    field(LNK2, "YCOR:IN20:342:EACT.PROC PP")
    field(LNK3, "YCOR:IN20:342:EERR.DISA PP")
    field(LNK4, "YCOR:IN20:342:ECON.PROC PP")
    field(LNK5, "YCOR:IN20:342:BMAGX.PROC PP")
    field(LNK6, "YCOR:IN20:342:BMAGY.PROC PP")
    field(LNK7, "YCOR:IN20:342:BLEM.PROC PP")
    field(LNK8, "YCOR:IN20:342:BMOD.PROC PP")
    field(LNK9, "YCOR:IN20:342:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:IN20:342:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:IN20:342:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:IN20:342:BMAX")
  field(DOL2, "YCOR:IN20:342:BMAX")
  field(DOL3, "YCOR:IN20:342:BMAX")
  field(DOL4, "YCOR:IN20:342:BMIN")
  field(DOL5, "YCOR:IN20:342:BMIN")
  field(DOL6, "YCOR:IN20:342:BMIN")
  field(LNK1, "YCOR:IN20:342:BMAGX.HOPR")
  field(LNK2, "YCOR:IN20:342:BMAGY.HOPR")
  field(LNK3, "YCOR:IN20:342:BLEM.HOPR")
  field(LNK4, "YCOR:IN20:342:BMAGX.LOPR PP")
  field(LNK5, "YCOR:IN20:342:BMAGY.LOPR PP")
  field(LNK6, "YCOR:IN20:342:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:342:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:342:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:IN20:342:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:IN20:342:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:IN20:342:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:342:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:342:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:342:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:342:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:342:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:IN20:342:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:IN20:342:EDES NPP MS")
  field(INPB, "YCOR:IN20:342:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:IN20:382:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "YCOR:IN20:382:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:IN20:382:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:IN20:382:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:IN20:382:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:IN20:382:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:IN20:382:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:IN20:382:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:IN20:382:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:IN20:382:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:IN20:382:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:IN20:382:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:IN20:382:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:IN20:382:EDES.PROC PP")
    field(LNK2, "YCOR:IN20:382:EACT.PROC PP")
    field(LNK3, "YCOR:IN20:382:EERR.DISA PP")
    field(LNK4, "YCOR:IN20:382:ECON.PROC PP")
    field(LNK5, "YCOR:IN20:382:BMAGX.PROC PP")
    field(LNK6, "YCOR:IN20:382:BMAGY.PROC PP")
    field(LNK7, "YCOR:IN20:382:BLEM.PROC PP")
    field(LNK8, "YCOR:IN20:382:BMOD.PROC PP")
    field(LNK9, "YCOR:IN20:382:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:IN20:382:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:IN20:382:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:IN20:382:BMAX")
  field(DOL2, "YCOR:IN20:382:BMAX")
  field(DOL3, "YCOR:IN20:382:BMAX")
  field(DOL4, "YCOR:IN20:382:BMIN")
  field(DOL5, "YCOR:IN20:382:BMIN")
  field(DOL6, "YCOR:IN20:382:BMIN")
  field(LNK1, "YCOR:IN20:382:BMAGX.HOPR")
  field(LNK2, "YCOR:IN20:382:BMAGY.HOPR")
  field(LNK3, "YCOR:IN20:382:BLEM.HOPR")
  field(LNK4, "YCOR:IN20:382:BMAGX.LOPR PP")
  field(LNK5, "YCOR:IN20:382:BMAGY.LOPR PP")
  field(LNK6, "YCOR:IN20:382:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:382:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:382:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:IN20:382:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:IN20:382:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:IN20:382:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:382:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:382:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:382:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:382:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:382:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:IN20:382:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:IN20:382:EDES NPP MS")
  field(INPB, "YCOR:IN20:382:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:IN20:412:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "YCOR:IN20:412:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:IN20:412:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:IN20:412:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:IN20:412:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:IN20:412:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:IN20:412:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:IN20:412:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:IN20:412:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:IN20:412:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:IN20:412:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:IN20:412:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:IN20:412:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:IN20:412:EDES.PROC PP")
    field(LNK2, "YCOR:IN20:412:EACT.PROC PP")
    field(LNK3, "YCOR:IN20:412:EERR.DISA PP")
    field(LNK4, "YCOR:IN20:412:ECON.PROC PP")
    field(LNK5, "YCOR:IN20:412:BMAGX.PROC PP")
    field(LNK6, "YCOR:IN20:412:BMAGY.PROC PP")
    field(LNK7, "YCOR:IN20:412:BLEM.PROC PP")
    field(LNK8, "YCOR:IN20:412:BMOD.PROC PP")
    field(LNK9, "YCOR:IN20:412:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:IN20:412:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:IN20:412:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:IN20:412:BMAX")
  field(DOL2, "YCOR:IN20:412:BMAX")
  field(DOL3, "YCOR:IN20:412:BMAX")
  field(DOL4, "YCOR:IN20:412:BMIN")
  field(DOL5, "YCOR:IN20:412:BMIN")
  field(DOL6, "YCOR:IN20:412:BMIN")
  field(LNK1, "YCOR:IN20:412:BMAGX.HOPR")
  field(LNK2, "YCOR:IN20:412:BMAGY.HOPR")
  field(LNK3, "YCOR:IN20:412:BLEM.HOPR")
  field(LNK4, "YCOR:IN20:412:BMAGX.LOPR PP")
  field(LNK5, "YCOR:IN20:412:BMAGY.LOPR PP")
  field(LNK6, "YCOR:IN20:412:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:412:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:412:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:IN20:412:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:IN20:412:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:IN20:412:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:412:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:412:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:412:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:412:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:412:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:IN20:412:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:IN20:412:EDES NPP MS")
  field(INPB, "YCOR:IN20:412:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:IN20:492:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "YCOR:IN20:492:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:IN20:492:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:IN20:492:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:IN20:492:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:IN20:492:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:IN20:492:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:IN20:492:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:IN20:492:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:IN20:492:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:IN20:492:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:IN20:492:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:IN20:492:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:IN20:492:EDES.PROC PP")
    field(LNK2, "YCOR:IN20:492:EACT.PROC PP")
    field(LNK3, "YCOR:IN20:492:EERR.DISA PP")
    field(LNK4, "YCOR:IN20:492:ECON.PROC PP")
    field(LNK5, "YCOR:IN20:492:BMAGX.PROC PP")
    field(LNK6, "YCOR:IN20:492:BMAGY.PROC PP")
    field(LNK7, "YCOR:IN20:492:BLEM.PROC PP")
    field(LNK8, "YCOR:IN20:492:BMOD.PROC PP")
    field(LNK9, "YCOR:IN20:492:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:IN20:492:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:IN20:492:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:IN20:492:BMAX")
  field(DOL2, "YCOR:IN20:492:BMAX")
  field(DOL3, "YCOR:IN20:492:BMAX")
  field(DOL4, "YCOR:IN20:492:BMIN")
  field(DOL5, "YCOR:IN20:492:BMIN")
  field(DOL6, "YCOR:IN20:492:BMIN")
  field(LNK1, "YCOR:IN20:492:BMAGX.HOPR")
  field(LNK2, "YCOR:IN20:492:BMAGY.HOPR")
  field(LNK3, "YCOR:IN20:492:BLEM.HOPR")
  field(LNK4, "YCOR:IN20:492:BMAGX.LOPR PP")
  field(LNK5, "YCOR:IN20:492:BMAGY.LOPR PP")
  field(LNK6, "YCOR:IN20:492:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:492:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:492:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:IN20:492:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:IN20:492:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:IN20:492:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:492:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:492:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:492:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:492:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:492:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:IN20:492:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:IN20:492:EDES NPP MS")
  field(INPB, "YCOR:IN20:492:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:IN20:522:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "YCOR:IN20:522:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:IN20:522:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:IN20:522:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:IN20:522:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:IN20:522:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:IN20:522:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:IN20:522:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:IN20:522:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:IN20:522:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:IN20:522:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:IN20:522:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:IN20:522:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:IN20:522:EDES.PROC PP")
    field(LNK2, "YCOR:IN20:522:EACT.PROC PP")
    field(LNK3, "YCOR:IN20:522:EERR.DISA PP")
    field(LNK4, "YCOR:IN20:522:ECON.PROC PP")
    field(LNK5, "YCOR:IN20:522:BMAGX.PROC PP")
    field(LNK6, "YCOR:IN20:522:BMAGY.PROC PP")
    field(LNK7, "YCOR:IN20:522:BLEM.PROC PP")
    field(LNK8, "YCOR:IN20:522:BMOD.PROC PP")
    field(LNK9, "YCOR:IN20:522:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:IN20:522:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:IN20:522:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:IN20:522:BMAX")
  field(DOL2, "YCOR:IN20:522:BMAX")
  field(DOL3, "YCOR:IN20:522:BMAX")
  field(DOL4, "YCOR:IN20:522:BMIN")
  field(DOL5, "YCOR:IN20:522:BMIN")
  field(DOL6, "YCOR:IN20:522:BMIN")
  field(LNK1, "YCOR:IN20:522:BMAGX.HOPR")
  field(LNK2, "YCOR:IN20:522:BMAGY.HOPR")
  field(LNK3, "YCOR:IN20:522:BLEM.HOPR")
  field(LNK4, "YCOR:IN20:522:BMAGX.LOPR PP")
  field(LNK5, "YCOR:IN20:522:BMAGY.LOPR PP")
  field(LNK6, "YCOR:IN20:522:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:522:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:522:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:IN20:522:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:IN20:522:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:IN20:522:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:522:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:522:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:522:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:522:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:522:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:IN20:522:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:IN20:522:EDES NPP MS")
  field(INPB, "YCOR:IN20:522:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:IN20:642:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "YCOR:IN20:642:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:IN20:642:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:IN20:642:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:IN20:642:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:IN20:642:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:IN20:642:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:IN20:642:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:IN20:642:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:IN20:642:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:IN20:642:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:IN20:642:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:IN20:642:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:IN20:642:EDES.PROC PP")
    field(LNK2, "YCOR:IN20:642:EACT.PROC PP")
    field(LNK3, "YCOR:IN20:642:EERR.DISA PP")
    field(LNK4, "YCOR:IN20:642:ECON.PROC PP")
    field(LNK5, "YCOR:IN20:642:BMAGX.PROC PP")
    field(LNK6, "YCOR:IN20:642:BMAGY.PROC PP")
    field(LNK7, "YCOR:IN20:642:BLEM.PROC PP")
    field(LNK8, "YCOR:IN20:642:BMOD.PROC PP")
    field(LNK9, "YCOR:IN20:642:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:IN20:642:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:IN20:642:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:IN20:642:BMAX")
  field(DOL2, "YCOR:IN20:642:BMAX")
  field(DOL3, "YCOR:IN20:642:BMAX")
  field(DOL4, "YCOR:IN20:642:BMIN")
  field(DOL5, "YCOR:IN20:642:BMIN")
  field(DOL6, "YCOR:IN20:642:BMIN")
  field(LNK1, "YCOR:IN20:642:BMAGX.HOPR")
  field(LNK2, "YCOR:IN20:642:BMAGY.HOPR")
  field(LNK3, "YCOR:IN20:642:BLEM.HOPR")
  field(LNK4, "YCOR:IN20:642:BMAGX.LOPR PP")
  field(LNK5, "YCOR:IN20:642:BMAGY.LOPR PP")
  field(LNK6, "YCOR:IN20:642:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:642:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:642:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:IN20:642:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:IN20:642:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:IN20:642:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:642:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:642:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:642:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:642:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:642:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:IN20:642:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:IN20:642:EDES NPP MS")
  field(INPB, "YCOR:IN20:642:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:IN20:722:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "YCOR:IN20:722:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:IN20:722:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:IN20:722:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:IN20:722:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:IN20:722:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:IN20:722:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:IN20:722:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:IN20:722:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:IN20:722:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:IN20:722:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:IN20:722:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:IN20:722:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:IN20:722:EDES.PROC PP")
    field(LNK2, "YCOR:IN20:722:EACT.PROC PP")
    field(LNK3, "YCOR:IN20:722:EERR.DISA PP")
    field(LNK4, "YCOR:IN20:722:ECON.PROC PP")
    field(LNK5, "YCOR:IN20:722:BMAGX.PROC PP")
    field(LNK6, "YCOR:IN20:722:BMAGY.PROC PP")
    field(LNK7, "YCOR:IN20:722:BLEM.PROC PP")
    field(LNK8, "YCOR:IN20:722:BMOD.PROC PP")
    field(LNK9, "YCOR:IN20:722:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:IN20:722:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:IN20:722:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:IN20:722:BMAX")
  field(DOL2, "YCOR:IN20:722:BMAX")
  field(DOL3, "YCOR:IN20:722:BMAX")
  field(DOL4, "YCOR:IN20:722:BMIN")
  field(DOL5, "YCOR:IN20:722:BMIN")
  field(DOL6, "YCOR:IN20:722:BMIN")
  field(LNK1, "YCOR:IN20:722:BMAGX.HOPR")
  field(LNK2, "YCOR:IN20:722:BMAGY.HOPR")
  field(LNK3, "YCOR:IN20:722:BLEM.HOPR")
  field(LNK4, "YCOR:IN20:722:BMAGX.LOPR PP")
  field(LNK5, "YCOR:IN20:722:BMAGY.LOPR PP")
  field(LNK6, "YCOR:IN20:722:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:722:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:722:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:IN20:722:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:IN20:722:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:IN20:722:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:722:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:722:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:722:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:722:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:722:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:IN20:722:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:IN20:722:EDES NPP MS")
  field(INPB, "YCOR:IN20:722:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:IN20:762:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "YCOR:IN20:762:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:IN20:762:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:IN20:762:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:IN20:762:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:IN20:762:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:IN20:762:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:IN20:762:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:IN20:762:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:IN20:762:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:IN20:762:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:IN20:762:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:IN20:762:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:IN20:762:EDES.PROC PP")
    field(LNK2, "YCOR:IN20:762:EACT.PROC PP")
    field(LNK3, "YCOR:IN20:762:EERR.DISA PP")
    field(LNK4, "YCOR:IN20:762:ECON.PROC PP")
    field(LNK5, "YCOR:IN20:762:BMAGX.PROC PP")
    field(LNK6, "YCOR:IN20:762:BMAGY.PROC PP")
    field(LNK7, "YCOR:IN20:762:BLEM.PROC PP")
    field(LNK8, "YCOR:IN20:762:BMOD.PROC PP")
    field(LNK9, "YCOR:IN20:762:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:IN20:762:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:IN20:762:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:IN20:762:BMAX")
  field(DOL2, "YCOR:IN20:762:BMAX")
  field(DOL3, "YCOR:IN20:762:BMAX")
  field(DOL4, "YCOR:IN20:762:BMIN")
  field(DOL5, "YCOR:IN20:762:BMIN")
  field(DOL6, "YCOR:IN20:762:BMIN")
  field(LNK1, "YCOR:IN20:762:BMAGX.HOPR")
  field(LNK2, "YCOR:IN20:762:BMAGY.HOPR")
  field(LNK3, "YCOR:IN20:762:BLEM.HOPR")
  field(LNK4, "YCOR:IN20:762:BMAGX.LOPR PP")
  field(LNK5, "YCOR:IN20:762:BMAGY.LOPR PP")
  field(LNK6, "YCOR:IN20:762:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:762:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:762:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:IN20:762:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:IN20:762:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:IN20:762:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:762:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:762:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:762:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:762:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:762:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:IN20:762:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:IN20:762:EDES NPP MS")
  field(INPB, "YCOR:IN20:762:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:IN20:812:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "YCOR:IN20:812:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:IN20:812:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:IN20:812:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:IN20:812:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:IN20:812:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:IN20:812:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:IN20:812:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:IN20:812:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:IN20:812:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:IN20:812:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:IN20:812:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:IN20:812:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:IN20:812:EDES.PROC PP")
    field(LNK2, "YCOR:IN20:812:EACT.PROC PP")
    field(LNK3, "YCOR:IN20:812:EERR.DISA PP")
    field(LNK4, "YCOR:IN20:812:ECON.PROC PP")
    field(LNK5, "YCOR:IN20:812:BMAGX.PROC PP")
    field(LNK6, "YCOR:IN20:812:BMAGY.PROC PP")
    field(LNK7, "YCOR:IN20:812:BLEM.PROC PP")
    field(LNK8, "YCOR:IN20:812:BMOD.PROC PP")
    field(LNK9, "YCOR:IN20:812:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:IN20:812:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:IN20:812:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:IN20:812:BMAX")
  field(DOL2, "YCOR:IN20:812:BMAX")
  field(DOL3, "YCOR:IN20:812:BMAX")
  field(DOL4, "YCOR:IN20:812:BMIN")
  field(DOL5, "YCOR:IN20:812:BMIN")
  field(DOL6, "YCOR:IN20:812:BMIN")
  field(LNK1, "YCOR:IN20:812:BMAGX.HOPR")
  field(LNK2, "YCOR:IN20:812:BMAGY.HOPR")
  field(LNK3, "YCOR:IN20:812:BLEM.HOPR")
  field(LNK4, "YCOR:IN20:812:BMAGX.LOPR PP")
  field(LNK5, "YCOR:IN20:812:BMAGY.LOPR PP")
  field(LNK6, "YCOR:IN20:812:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:812:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:812:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:IN20:812:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:IN20:812:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:IN20:812:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:812:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:812:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:812:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:812:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:812:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:IN20:812:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:IN20:812:EDES NPP MS")
  field(INPB, "YCOR:IN20:812:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:IN20:832:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "YCOR:IN20:832:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:IN20:832:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:IN20:832:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:IN20:832:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:IN20:832:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:IN20:832:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:IN20:832:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:IN20:832:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:IN20:832:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:IN20:832:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:IN20:832:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:IN20:832:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:IN20:832:EDES.PROC PP")
    field(LNK2, "YCOR:IN20:832:EACT.PROC PP")
    field(LNK3, "YCOR:IN20:832:EERR.DISA PP")
    field(LNK4, "YCOR:IN20:832:ECON.PROC PP")
    field(LNK5, "YCOR:IN20:832:BMAGX.PROC PP")
    field(LNK6, "YCOR:IN20:832:BMAGY.PROC PP")
    field(LNK7, "YCOR:IN20:832:BLEM.PROC PP")
    field(LNK8, "YCOR:IN20:832:BMOD.PROC PP")
    field(LNK9, "YCOR:IN20:832:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:IN20:832:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:IN20:832:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:IN20:832:BMAX")
  field(DOL2, "YCOR:IN20:832:BMAX")
  field(DOL3, "YCOR:IN20:832:BMAX")
  field(DOL4, "YCOR:IN20:832:BMIN")
  field(DOL5, "YCOR:IN20:832:BMIN")
  field(DOL6, "YCOR:IN20:832:BMIN")
  field(LNK1, "YCOR:IN20:832:BMAGX.HOPR")
  field(LNK2, "YCOR:IN20:832:BMAGY.HOPR")
  field(LNK3, "YCOR:IN20:832:BLEM.HOPR")
  field(LNK4, "YCOR:IN20:832:BMAGX.LOPR PP")
  field(LNK5, "YCOR:IN20:832:BMAGY.LOPR PP")
  field(LNK6, "YCOR:IN20:832:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:832:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:832:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:IN20:832:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:IN20:832:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:IN20:832:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:832:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:832:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:832:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:832:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:832:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:IN20:832:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:IN20:832:EDES NPP MS")
  field(INPB, "YCOR:IN20:832:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:IN20:912:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "YCOR:IN20:912:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:IN20:912:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:IN20:912:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:IN20:912:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:IN20:912:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:IN20:912:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:IN20:912:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:IN20:912:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:IN20:912:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:IN20:912:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:IN20:912:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:IN20:912:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:IN20:912:EDES.PROC PP")
    field(LNK2, "YCOR:IN20:912:EACT.PROC PP")
    field(LNK3, "YCOR:IN20:912:EERR.DISA PP")
    field(LNK4, "YCOR:IN20:912:ECON.PROC PP")
    field(LNK5, "YCOR:IN20:912:BMAGX.PROC PP")
    field(LNK6, "YCOR:IN20:912:BMAGY.PROC PP")
    field(LNK7, "YCOR:IN20:912:BLEM.PROC PP")
    field(LNK8, "YCOR:IN20:912:BMOD.PROC PP")
    field(LNK9, "YCOR:IN20:912:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:IN20:912:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:IN20:912:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:IN20:912:BMAX")
  field(DOL2, "YCOR:IN20:912:BMAX")
  field(DOL3, "YCOR:IN20:912:BMAX")
  field(DOL4, "YCOR:IN20:912:BMIN")
  field(DOL5, "YCOR:IN20:912:BMIN")
  field(DOL6, "YCOR:IN20:912:BMIN")
  field(LNK1, "YCOR:IN20:912:BMAGX.HOPR")
  field(LNK2, "YCOR:IN20:912:BMAGY.HOPR")
  field(LNK3, "YCOR:IN20:912:BLEM.HOPR")
  field(LNK4, "YCOR:IN20:912:BMAGX.LOPR PP")
  field(LNK5, "YCOR:IN20:912:BMAGY.LOPR PP")
  field(LNK6, "YCOR:IN20:912:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:912:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:912:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:IN20:912:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:IN20:912:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:IN20:912:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:912:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:912:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:912:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:912:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:912:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:IN20:912:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:IN20:912:EDES NPP MS")
  field(INPB, "YCOR:IN20:912:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:IN20:952:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "YCOR:IN20:952:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:IN20:952:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:IN20:952:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:IN20:952:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:IN20:952:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:IN20:952:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:IN20:952:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:IN20:952:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:IN20:952:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:IN20:952:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:IN20:952:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:IN20:952:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:IN20:952:EDES.PROC PP")
    field(LNK2, "YCOR:IN20:952:EACT.PROC PP")
    field(LNK3, "YCOR:IN20:952:EERR.DISA PP")
    field(LNK4, "YCOR:IN20:952:ECON.PROC PP")
    field(LNK5, "YCOR:IN20:952:BMAGX.PROC PP")
    field(LNK6, "YCOR:IN20:952:BMAGY.PROC PP")
    field(LNK7, "YCOR:IN20:952:BLEM.PROC PP")
    field(LNK8, "YCOR:IN20:952:BMOD.PROC PP")
    field(LNK9, "YCOR:IN20:952:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:IN20:952:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:IN20:952:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:IN20:952:BMAX")
  field(DOL2, "YCOR:IN20:952:BMAX")
  field(DOL3, "YCOR:IN20:952:BMAX")
  field(DOL4, "YCOR:IN20:952:BMIN")
  field(DOL5, "YCOR:IN20:952:BMIN")
  field(DOL6, "YCOR:IN20:952:BMIN")
  field(LNK1, "YCOR:IN20:952:BMAGX.HOPR")
  field(LNK2, "YCOR:IN20:952:BMAGY.HOPR")
  field(LNK3, "YCOR:IN20:952:BLEM.HOPR")
  field(LNK4, "YCOR:IN20:952:BMAGX.LOPR PP")
  field(LNK5, "YCOR:IN20:952:BMAGY.LOPR PP")
  field(LNK6, "YCOR:IN20:952:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:952:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:IN20:952:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:IN20:952:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:IN20:952:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:IN20:952:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:952:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:952:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:952:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:IN20:952:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:IN20:952:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:IN20:952:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:IN20:952:EDES NPP MS")
  field(INPB, "YCOR:IN20:952:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:IN20:451:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "BEND:IN20:451:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:IN20:451:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:IN20:451:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:IN20:451:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:IN20:451:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:IN20:451:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:IN20:451:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:IN20:451:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:IN20:451:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:IN20:451:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:IN20:451:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:IN20:451:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:IN20:451:EDES.PROC PP")
    field(LNK2, "BEND:IN20:451:EACT.PROC PP")
    field(LNK3, "BEND:IN20:451:EERR.DISA PP")
    field(LNK4, "BEND:IN20:451:ECON.PROC PP")
    field(LNK5, "BEND:IN20:451:BMAGX.PROC PP")
    field(LNK6, "BEND:IN20:451:BMAGY.PROC PP")
    field(LNK7, "BEND:IN20:451:BLEM.PROC PP")
    field(LNK8, "BEND:IN20:451:BMOD.PROC PP")
    field(LNK9, "BEND:IN20:451:EDESSAVE.PROC PP")
    field(LNKA, "BEND:IN20:451:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:IN20:451:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:IN20:451:BMAX")
  field(DOL2, "BEND:IN20:451:BMAX")
  field(DOL3, "BEND:IN20:451:BMAX")
  field(DOL4, "BEND:IN20:451:BMIN")
  field(DOL5, "BEND:IN20:451:BMIN")
  field(DOL6, "BEND:IN20:451:BMIN")
  field(LNK1, "BEND:IN20:451:BMAGX.HOPR")
  field(LNK2, "BEND:IN20:451:BMAGY.HOPR")
  field(LNK3, "BEND:IN20:451:BLEM.HOPR")
  field(LNK4, "BEND:IN20:451:BMAGX.LOPR PP")
  field(LNK5, "BEND:IN20:451:BMAGY.LOPR PP")
  field(LNK6, "BEND:IN20:451:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:451:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:451:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:IN20:451:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:IN20:451:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:IN20:451:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:451:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:IN20:461:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:451:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:IN20:461:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:IN20:451:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:451:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:IN20:461:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:IN20:451:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:IN20:451:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:IN20:451:EDES NPP MS")
  field(INPB, "BEND:IN20:451:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:IN20:475:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "BEND:IN20:475:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:IN20:475:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:IN20:475:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:IN20:475:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:IN20:475:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:IN20:475:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:IN20:475:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:IN20:475:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:IN20:475:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:IN20:475:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:IN20:475:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:IN20:475:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:IN20:475:EDES.PROC PP")
    field(LNK2, "BEND:IN20:475:EACT.PROC PP")
    field(LNK3, "BEND:IN20:475:EERR.DISA PP")
    field(LNK4, "BEND:IN20:475:ECON.PROC PP")
    field(LNK5, "BEND:IN20:475:BMAGX.PROC PP")
    field(LNK6, "BEND:IN20:475:BMAGY.PROC PP")
    field(LNK7, "BEND:IN20:475:BLEM.PROC PP")
    field(LNK8, "BEND:IN20:475:BMOD.PROC PP")
    field(LNK9, "BEND:IN20:475:EDESSAVE.PROC PP")
    field(LNKA, "BEND:IN20:475:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:IN20:475:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:IN20:475:BMAX")
  field(DOL2, "BEND:IN20:475:BMAX")
  field(DOL3, "BEND:IN20:475:BMAX")
  field(DOL4, "BEND:IN20:475:BMIN")
  field(DOL5, "BEND:IN20:475:BMIN")
  field(DOL6, "BEND:IN20:475:BMIN")
  field(LNK1, "BEND:IN20:475:BMAGX.HOPR")
  field(LNK2, "BEND:IN20:475:BMAGY.HOPR")
  field(LNK3, "BEND:IN20:475:BLEM.HOPR")
  field(LNK4, "BEND:IN20:475:BMAGX.LOPR PP")
  field(LNK5, "BEND:IN20:475:BMAGY.LOPR PP")
  field(LNK6, "BEND:IN20:475:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:475:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:475:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:IN20:475:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:IN20:475:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:IN20:475:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:475:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:IN20:461:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:475:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:IN20:461:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:IN20:475:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:475:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:IN20:461:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:IN20:475:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:IN20:475:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:IN20:475:EDES NPP MS")
  field(INPB, "BEND:IN20:475:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:IN20:481:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "BEND:IN20:481:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:IN20:481:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:IN20:481:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:IN20:481:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:IN20:481:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:IN20:481:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:IN20:481:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:IN20:481:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:IN20:481:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:IN20:481:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:IN20:481:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:IN20:481:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:IN20:481:EDES.PROC PP")
    field(LNK2, "BEND:IN20:481:EACT.PROC PP")
    field(LNK3, "BEND:IN20:481:EERR.DISA PP")
    field(LNK4, "BEND:IN20:481:ECON.PROC PP")
    field(LNK5, "BEND:IN20:481:BMAGX.PROC PP")
    field(LNK6, "BEND:IN20:481:BMAGY.PROC PP")
    field(LNK7, "BEND:IN20:481:BLEM.PROC PP")
    field(LNK8, "BEND:IN20:481:BMOD.PROC PP")
    field(LNK9, "BEND:IN20:481:EDESSAVE.PROC PP")
    field(LNKA, "BEND:IN20:481:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:IN20:481:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:IN20:481:BMAX")
  field(DOL2, "BEND:IN20:481:BMAX")
  field(DOL3, "BEND:IN20:481:BMAX")
  field(DOL4, "BEND:IN20:481:BMIN")
  field(DOL5, "BEND:IN20:481:BMIN")
  field(DOL6, "BEND:IN20:481:BMIN")
  field(LNK1, "BEND:IN20:481:BMAGX.HOPR")
  field(LNK2, "BEND:IN20:481:BMAGY.HOPR")
  field(LNK3, "BEND:IN20:481:BLEM.HOPR")
  field(LNK4, "BEND:IN20:481:BMAGX.LOPR PP")
  field(LNK5, "BEND:IN20:481:BMAGY.LOPR PP")
  field(LNK6, "BEND:IN20:481:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:481:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:481:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:IN20:481:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:IN20:481:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:IN20:481:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:481:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:IN20:461:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:481:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:IN20:461:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:IN20:481:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:481:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:IN20:461:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:IN20:481:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:IN20:481:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:IN20:481:EDES NPP MS")
  field(INPB, "BEND:IN20:481:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:IN20:661:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:IN20:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:IN20:1:CTRL.RVAL")
  field(LNK1, "BEND:IN20:661:FUNC CA PP")
  field(DOL2, "MGNT:IN20:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:IN20:661:FUNC CA PP")
  field(DOL3, "MGNT:IN20:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:IN20:661:FUNC CA PP")
  field(DOL4, "MGNT:IN20:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:IN20:661:FUNC CA PP")
  field(DOL5, "MGNT:IN20:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:IN20:661:FUNC CA PP")
  field(DOL6, "MGNT:IN20:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:IN20:661:FUNC CA PP")
  field(DOL7, "MGNT:IN20:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:IN20:661:FUNC CA PP")
  field(DOL8, "MGNT:IN20:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:IN20:661:FUNC CA PP")
  field(DOL9, "MGNT:IN20:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:IN20:661:FUNC CA PP")
  field(DOLA, "MGNT:IN20:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:IN20:661:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:IN20:661:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:IN20:661:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:IN20:661:EDES.PROC PP")
    field(LNK2, "BEND:IN20:661:EACT.PROC PP")
    field(LNK3, "BEND:IN20:661:EERR.DISA PP")
    field(LNK4, "BEND:IN20:661:ECON.PROC PP")
    field(LNK5, "BEND:IN20:661:BMAGX.PROC PP")
    field(LNK6, "BEND:IN20:661:BMAGY.PROC PP")
    field(LNK7, "BEND:IN20:661:BLEM.PROC PP")
    field(LNK8, "BEND:IN20:661:BMOD.PROC PP")
    field(LNK9, "BEND:IN20:661:EDESSAVE.PROC PP")
    field(LNKA, "BEND:IN20:661:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:IN20:661:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:IN20:661:BMAX")
  field(DOL2, "BEND:IN20:661:BMAX")
  field(DOL3, "BEND:IN20:661:BMAX")
  field(DOL4, "BEND:IN20:661:BMIN")
  field(DOL5, "BEND:IN20:661:BMIN")
  field(DOL6, "BEND:IN20:661:BMIN")
  field(LNK1, "BEND:IN20:661:BMAGX.HOPR")
  field(LNK2, "BEND:IN20:661:BMAGY.HOPR")
  field(LNK3, "BEND:IN20:661:BLEM.HOPR")
  field(LNK4, "BEND:IN20:661:BMAGX.LOPR PP")
  field(LNK5, "BEND:IN20:661:BMAGY.LOPR PP")
  field(LNK6, "BEND:IN20:661:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:661:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:IN20:661:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:IN20:661:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:IN20:661:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:IN20:661:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:661:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:IN20:751:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:661:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:IN20:751:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:IN20:661:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:IN20:661:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:IN20:751:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:IN20:661:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:IN20:661:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:IN20:661:EDES NPP MS")
  field(INPB, "BEND:IN20:661:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:LI21:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:LI21:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:LI21:1:CTRL CA PP")
  field(LNK2, "MGNT:LI21:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:LI21:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:LI21:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:LI21:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:LI21:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:LI21:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:LI21:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:LI21:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:LI21:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:LI21:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:LI21:1:ALLSWITCH")
}

record(seq, "MGNT:LI21:1:ALLSWITCH") {
  field(DOL1, "MGNT:LI21:1:CTRL.FFVL")
  field(LNK1, "MGNT:LI21:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI21:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI21:1:CTRL")
}

record(bo, "MGNT:LI21:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:LI21:1:ALLSTARGO")
}

record(fanout, "MGNT:LI21:1:ALLSTARGO") {
  field(LNK1, "MGNT:LI21:1:ALLBENDSGO")
  field(LNK2, "MGNT:LI21:1:ALLBTRMSGO")
  field(LNK3, "MGNT:LI21:1:ALLLGPSSGO")
  field(LNK4, "MGNT:LI21:1:ALLQUADSGO")
  field(LNK5, "MGNT:LI21:1:ALLXCORSGO")
  field(LNK6, "MGNT:LI21:1:ALLYCORSGO")
  field(FLNK, "MGNT:LI21:1:ALLSTARGO_2")
}
record(fanout, "MGNT:LI21:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:LI21:1:ALLSOLNSGO")
  field(LNK2, "MGNT:LI21:1:ALLKICKSGO")
  field(LNK3, "MGNT:LI21:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:LI21:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:LI21:1:BENDSWITCH")
}

record(seq, "MGNT:LI21:1:BENDSWITCH") {
  field(DOL1, "MGNT:LI21:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:LI21:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI21:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI21:1:BENDCTRL")
}

record(seq, "MGNT:LI21:1:ALLBENDSGO") {
  field(DOL1, "MGNT:LI21:1:ALLSTAR")
  field(LNK1, "MGNT:LI21:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:LI21:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI21:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI21:1:BENDCTRL",20,10,0,0,"MGNT:LI21:1:BENDCTRL")
#! Field("MGNT:LI21:1:BENDCTRL.FLNK",16777215,1,"MGNT:LI21:1:BENDCTRL.FLNK")
#! Link("MGNT:LI21:1:BENDCTRL.FLNK","MGNT:LI21:1:BENDSWITCH")
#! Field("MGNT:LI21:1:BENDCTRL.FFVL",16777215,1,"MGNT:LI21:1:BENDCTRL.FFVL")
#! Record("MGNT:LI21:1:BENDSWITCH",460,322,0,0,"MGNT:LI21:1:BENDSWITCH")
#! Field("MGNT:LI21:1:BENDSWITCH.DOL1",16777215,0,"MGNT:LI21:1:BENDSWITCH.DOL1")
#! Link("MGNT:LI21:1:BENDSWITCH.DOL1","MGNT:LI21:1:BENDCTRL.FFVL")
#! Field("MGNT:LI21:1:BENDSWITCH.LNK1",16777215,1,"MGNT:LI21:1:BENDSWITCH.LNK1")
#! Field("MGNT:LI21:1:BENDSWITCH.FLNK",16777215,1,"MGNT:LI21:1:BENDSWITCH.FLNK")
#! Record("MGNT:LI21:1:ALLBENDSGO",240,96,0,0,"MGNT:LI21:1:ALLBENDSGO")
#! Field("MGNT:LI21:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:LI21:1:ALLBENDSGO.DOL1")
#! Field("MGNT:LI21:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:LI21:1:ALLBENDSGO.LNK1")
#! Link("MGNT:LI21:1:ALLBENDSGO.LNK1","MGNT:LI21:1:ALLBENDS.VAL")
#! Record("MGNT:LI21:1:ALLBENDS",540,102,0,0,"MGNT:LI21:1:ALLBENDS")
#! Field("MGNT:LI21:1:ALLBENDS.VAL",16777215,0,"MGNT:LI21:1:ALLBENDS.VAL")
#! Field("MGNT:LI21:1:ALLBENDS.FLNK",16777215,1,"MGNT:LI21:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:LI21:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI21:1:BTRMSWITCH")
}

record(seq, "MGNT:LI21:1:BTRMSWITCH") {
  field(DOL1, "MGNT:LI21:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:LI21:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI21:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI21:1:BTRMCTRL")
}

record(seq, "MGNT:LI21:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:LI21:1:ALLSTAR")
  field(LNK1, "MGNT:LI21:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:LI21:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI21:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI21:1:BTRMCTRL",20,10,0,0,"MGNT:LI21:1:BTRMCTRL")
#! Field("MGNT:LI21:1:BTRMCTRL.FLNK",16777215,1,"MGNT:LI21:1:BTRMCTRL.FLNK")
#! Link("MGNT:LI21:1:BTRMCTRL.FLNK","MGNT:LI21:1:BTRMSWITCH")
#! Field("MGNT:LI21:1:BTRMCTRL.FFVL",16777215,1,"MGNT:LI21:1:BTRMCTRL.FFVL")
#! Record("MGNT:LI21:1:BTRMSWITCH",460,322,0,0,"MGNT:LI21:1:BTRMSWITCH")
#! Field("MGNT:LI21:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:LI21:1:BTRMSWITCH.DOL1")
#! Link("MGNT:LI21:1:BTRMSWITCH.DOL1","MGNT:LI21:1:BTRMCTRL.FFVL")
#! Field("MGNT:LI21:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:LI21:1:BTRMSWITCH.LNK1")
#! Field("MGNT:LI21:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:LI21:1:BTRMSWITCH.FLNK")
#! Record("MGNT:LI21:1:ALLBTRMSGO",240,96,0,0,"MGNT:LI21:1:ALLBTRMSGO")
#! Field("MGNT:LI21:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:LI21:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:LI21:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:LI21:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:LI21:1:ALLBTRMSGO.LNK1","MGNT:LI21:1:ALLBTRMS.VAL")
#! Record("MGNT:LI21:1:ALLBTRMS",540,102,0,0,"MGNT:LI21:1:ALLBTRMS")
#! Field("MGNT:LI21:1:ALLBTRMS.VAL",16777215,0,"MGNT:LI21:1:ALLBTRMS.VAL")
#! Field("MGNT:LI21:1:ALLBTRMS.FLNK",16777215,1,"MGNT:LI21:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:LI21:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI21:1:LGPSSWITCH")
}

record(seq, "MGNT:LI21:1:LGPSSWITCH") {
  field(DOL1, "MGNT:LI21:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:LI21:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI21:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI21:1:LGPSCTRL")
}

record(seq, "MGNT:LI21:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:LI21:1:ALLSTAR")
  field(LNK1, "MGNT:LI21:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:LI21:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI21:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI21:1:LGPSCTRL",20,10,0,0,"MGNT:LI21:1:LGPSCTRL")
#! Field("MGNT:LI21:1:LGPSCTRL.FLNK",16777215,1,"MGNT:LI21:1:LGPSCTRL.FLNK")
#! Link("MGNT:LI21:1:LGPSCTRL.FLNK","MGNT:LI21:1:LGPSSWITCH")
#! Field("MGNT:LI21:1:LGPSCTRL.FFVL",16777215,1,"MGNT:LI21:1:LGPSCTRL.FFVL")
#! Record("MGNT:LI21:1:LGPSSWITCH",460,322,0,0,"MGNT:LI21:1:LGPSSWITCH")
#! Field("MGNT:LI21:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:LI21:1:LGPSSWITCH.DOL1")
#! Link("MGNT:LI21:1:LGPSSWITCH.DOL1","MGNT:LI21:1:LGPSCTRL.FFVL")
#! Field("MGNT:LI21:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:LI21:1:LGPSSWITCH.LNK1")
#! Field("MGNT:LI21:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:LI21:1:LGPSSWITCH.FLNK")
#! Record("MGNT:LI21:1:ALLLGPSSGO",240,96,0,0,"MGNT:LI21:1:ALLLGPSSGO")
#! Field("MGNT:LI21:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:LI21:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:LI21:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:LI21:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:LI21:1:ALLLGPSSGO.LNK1","MGNT:LI21:1:ALLLGPSS.VAL")
#! Record("MGNT:LI21:1:ALLLGPSS",540,102,0,0,"MGNT:LI21:1:ALLLGPSS")
#! Field("MGNT:LI21:1:ALLLGPSS.VAL",16777215,0,"MGNT:LI21:1:ALLLGPSS.VAL")
#! Field("MGNT:LI21:1:ALLLGPSS.FLNK",16777215,1,"MGNT:LI21:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:LI21:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:LI21:1:QUADSWITCH")
}

record(seq, "MGNT:LI21:1:QUADSWITCH") {
  field(DOL1, "MGNT:LI21:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:LI21:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI21:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI21:1:QUADCTRL")
}

record(seq, "MGNT:LI21:1:ALLQUADSGO") {
  field(DOL1, "MGNT:LI21:1:ALLSTAR")
  field(LNK1, "MGNT:LI21:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:LI21:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI21:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI21:1:QUADCTRL",20,10,0,0,"MGNT:LI21:1:QUADCTRL")
#! Field("MGNT:LI21:1:QUADCTRL.FLNK",16777215,1,"MGNT:LI21:1:QUADCTRL.FLNK")
#! Link("MGNT:LI21:1:QUADCTRL.FLNK","MGNT:LI21:1:QUADSWITCH")
#! Field("MGNT:LI21:1:QUADCTRL.FFVL",16777215,1,"MGNT:LI21:1:QUADCTRL.FFVL")
#! Record("MGNT:LI21:1:QUADSWITCH",460,322,0,0,"MGNT:LI21:1:QUADSWITCH")
#! Field("MGNT:LI21:1:QUADSWITCH.DOL1",16777215,0,"MGNT:LI21:1:QUADSWITCH.DOL1")
#! Link("MGNT:LI21:1:QUADSWITCH.DOL1","MGNT:LI21:1:QUADCTRL.FFVL")
#! Field("MGNT:LI21:1:QUADSWITCH.LNK1",16777215,1,"MGNT:LI21:1:QUADSWITCH.LNK1")
#! Field("MGNT:LI21:1:QUADSWITCH.FLNK",16777215,1,"MGNT:LI21:1:QUADSWITCH.FLNK")
#! Record("MGNT:LI21:1:ALLQUADSGO",240,96,0,0,"MGNT:LI21:1:ALLQUADSGO")
#! Field("MGNT:LI21:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:LI21:1:ALLQUADSGO.DOL1")
#! Field("MGNT:LI21:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:LI21:1:ALLQUADSGO.LNK1")
#! Link("MGNT:LI21:1:ALLQUADSGO.LNK1","MGNT:LI21:1:ALLQUADS.VAL")
#! Record("MGNT:LI21:1:ALLQUADS",540,102,0,0,"MGNT:LI21:1:ALLQUADS")
#! Field("MGNT:LI21:1:ALLQUADS.VAL",16777215,0,"MGNT:LI21:1:ALLQUADS.VAL")
#! Field("MGNT:LI21:1:ALLQUADS.FLNK",16777215,1,"MGNT:LI21:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:LI21:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:LI21:1:XCORSWITCH")
}

record(seq, "MGNT:LI21:1:XCORSWITCH") {
  field(DOL1, "MGNT:LI21:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:LI21:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI21:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI21:1:XCORCTRL")
}

record(seq, "MGNT:LI21:1:ALLXCORSGO") {
  field(DOL1, "MGNT:LI21:1:ALLSTAR")
  field(LNK1, "MGNT:LI21:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:LI21:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI21:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI21:1:XCORCTRL",20,10,0,0,"MGNT:LI21:1:XCORCTRL")
#! Field("MGNT:LI21:1:XCORCTRL.FLNK",16777215,1,"MGNT:LI21:1:XCORCTRL.FLNK")
#! Link("MGNT:LI21:1:XCORCTRL.FLNK","MGNT:LI21:1:XCORSWITCH")
#! Field("MGNT:LI21:1:XCORCTRL.FFVL",16777215,1,"MGNT:LI21:1:XCORCTRL.FFVL")
#! Record("MGNT:LI21:1:XCORSWITCH",460,322,0,0,"MGNT:LI21:1:XCORSWITCH")
#! Field("MGNT:LI21:1:XCORSWITCH.DOL1",16777215,0,"MGNT:LI21:1:XCORSWITCH.DOL1")
#! Link("MGNT:LI21:1:XCORSWITCH.DOL1","MGNT:LI21:1:XCORCTRL.FFVL")
#! Field("MGNT:LI21:1:XCORSWITCH.LNK1",16777215,1,"MGNT:LI21:1:XCORSWITCH.LNK1")
#! Field("MGNT:LI21:1:XCORSWITCH.FLNK",16777215,1,"MGNT:LI21:1:XCORSWITCH.FLNK")
#! Record("MGNT:LI21:1:ALLXCORSGO",240,96,0,0,"MGNT:LI21:1:ALLXCORSGO")
#! Field("MGNT:LI21:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:LI21:1:ALLXCORSGO.DOL1")
#! Field("MGNT:LI21:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:LI21:1:ALLXCORSGO.LNK1")
#! Link("MGNT:LI21:1:ALLXCORSGO.LNK1","MGNT:LI21:1:ALLXCORS.VAL")
#! Record("MGNT:LI21:1:ALLXCORS",540,102,0,0,"MGNT:LI21:1:ALLXCORS")
#! Field("MGNT:LI21:1:ALLXCORS.VAL",16777215,0,"MGNT:LI21:1:ALLXCORS.VAL")
#! Field("MGNT:LI21:1:ALLXCORS.FLNK",16777215,1,"MGNT:LI21:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:LI21:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:LI21:1:YCORSWITCH")
}

record(seq, "MGNT:LI21:1:YCORSWITCH") {
  field(DOL1, "MGNT:LI21:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:LI21:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI21:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI21:1:YCORCTRL")
}

record(seq, "MGNT:LI21:1:ALLYCORSGO") {
  field(DOL1, "MGNT:LI21:1:ALLSTAR")
  field(LNK1, "MGNT:LI21:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:LI21:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI21:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI21:1:YCORCTRL",20,10,0,0,"MGNT:LI21:1:YCORCTRL")
#! Field("MGNT:LI21:1:YCORCTRL.FLNK",16777215,1,"MGNT:LI21:1:YCORCTRL.FLNK")
#! Link("MGNT:LI21:1:YCORCTRL.FLNK","MGNT:LI21:1:YCORSWITCH")
#! Field("MGNT:LI21:1:YCORCTRL.FFVL",16777215,1,"MGNT:LI21:1:YCORCTRL.FFVL")
#! Record("MGNT:LI21:1:YCORSWITCH",460,322,0,0,"MGNT:LI21:1:YCORSWITCH")
#! Field("MGNT:LI21:1:YCORSWITCH.DOL1",16777215,0,"MGNT:LI21:1:YCORSWITCH.DOL1")
#! Link("MGNT:LI21:1:YCORSWITCH.DOL1","MGNT:LI21:1:YCORCTRL.FFVL")
#! Field("MGNT:LI21:1:YCORSWITCH.LNK1",16777215,1,"MGNT:LI21:1:YCORSWITCH.LNK1")
#! Field("MGNT:LI21:1:YCORSWITCH.FLNK",16777215,1,"MGNT:LI21:1:YCORSWITCH.FLNK")
#! Record("MGNT:LI21:1:ALLYCORSGO",240,96,0,0,"MGNT:LI21:1:ALLYCORSGO")
#! Field("MGNT:LI21:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:LI21:1:ALLYCORSGO.DOL1")
#! Field("MGNT:LI21:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:LI21:1:ALLYCORSGO.LNK1")
#! Link("MGNT:LI21:1:ALLYCORSGO.LNK1","MGNT:LI21:1:ALLYCORS.VAL")
#! Record("MGNT:LI21:1:ALLYCORS",540,102,0,0,"MGNT:LI21:1:ALLYCORS")
#! Field("MGNT:LI21:1:ALLYCORS.VAL",16777215,0,"MGNT:LI21:1:ALLYCORS.VAL")
#! Field("MGNT:LI21:1:ALLYCORS.FLNK",16777215,1,"MGNT:LI21:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:LI21:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:LI21:1:SOLNSWITCH")
}

record(seq, "MGNT:LI21:1:SOLNSWITCH") {
  field(DOL1, "MGNT:LI21:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:LI21:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI21:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI21:1:SOLNCTRL")
}

record(seq, "MGNT:LI21:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:LI21:1:ALLSTAR")
  field(LNK1, "MGNT:LI21:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:LI21:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI21:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI21:1:SOLNCTRL",20,10,0,0,"MGNT:LI21:1:SOLNCTRL")
#! Field("MGNT:LI21:1:SOLNCTRL.FLNK",16777215,1,"MGNT:LI21:1:SOLNCTRL.FLNK")
#! Link("MGNT:LI21:1:SOLNCTRL.FLNK","MGNT:LI21:1:SOLNSWITCH")
#! Field("MGNT:LI21:1:SOLNCTRL.FFVL",16777215,1,"MGNT:LI21:1:SOLNCTRL.FFVL")
#! Record("MGNT:LI21:1:SOLNSWITCH",460,322,0,0,"MGNT:LI21:1:SOLNSWITCH")
#! Field("MGNT:LI21:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:LI21:1:SOLNSWITCH.DOL1")
#! Link("MGNT:LI21:1:SOLNSWITCH.DOL1","MGNT:LI21:1:SOLNCTRL.FFVL")
#! Field("MGNT:LI21:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:LI21:1:SOLNSWITCH.LNK1")
#! Field("MGNT:LI21:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:LI21:1:SOLNSWITCH.FLNK")
#! Record("MGNT:LI21:1:ALLSOLNSGO",240,96,0,0,"MGNT:LI21:1:ALLSOLNSGO")
#! Field("MGNT:LI21:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:LI21:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:LI21:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:LI21:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:LI21:1:ALLSOLNSGO.LNK1","MGNT:LI21:1:ALLSOLNS.VAL")
#! Record("MGNT:LI21:1:ALLSOLNS",540,102,0,0,"MGNT:LI21:1:ALLSOLNS")
#! Field("MGNT:LI21:1:ALLSOLNS.VAL",16777215,0,"MGNT:LI21:1:ALLSOLNS.VAL")
#! Field("MGNT:LI21:1:ALLSOLNS.FLNK",16777215,1,"MGNT:LI21:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:LI21:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:LI21:1:KICKSWITCH")
}

record(seq, "MGNT:LI21:1:KICKSWITCH") {
  field(DOL1, "MGNT:LI21:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:LI21:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI21:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI21:1:KICKCTRL")
}

record(seq, "MGNT:LI21:1:ALLKICKSGO") {
  field(DOL1, "MGNT:LI21:1:ALLSTAR")
  field(LNK1, "MGNT:LI21:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:LI21:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI21:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI21:1:KICKCTRL",20,10,0,0,"MGNT:LI21:1:KICKCTRL")
#! Field("MGNT:LI21:1:KICKCTRL.FLNK",16777215,1,"MGNT:LI21:1:KICKCTRL.FLNK")
#! Link("MGNT:LI21:1:KICKCTRL.FLNK","MGNT:LI21:1:KICKSWITCH")
#! Field("MGNT:LI21:1:KICKCTRL.FFVL",16777215,1,"MGNT:LI21:1:KICKCTRL.FFVL")
#! Record("MGNT:LI21:1:KICKSWITCH",460,322,0,0,"MGNT:LI21:1:KICKSWITCH")
#! Field("MGNT:LI21:1:KICKSWITCH.DOL1",16777215,0,"MGNT:LI21:1:KICKSWITCH.DOL1")
#! Link("MGNT:LI21:1:KICKSWITCH.DOL1","MGNT:LI21:1:KICKCTRL.FFVL")
#! Field("MGNT:LI21:1:KICKSWITCH.LNK1",16777215,1,"MGNT:LI21:1:KICKSWITCH.LNK1")
#! Field("MGNT:LI21:1:KICKSWITCH.FLNK",16777215,1,"MGNT:LI21:1:KICKSWITCH.FLNK")
#! Record("MGNT:LI21:1:ALLKICKSGO",240,96,0,0,"MGNT:LI21:1:ALLKICKSGO")
#! Field("MGNT:LI21:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:LI21:1:ALLKICKSGO.DOL1")
#! Field("MGNT:LI21:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:LI21:1:ALLKICKSGO.LNK1")
#! Link("MGNT:LI21:1:ALLKICKSGO.LNK1","MGNT:LI21:1:ALLKICKS.VAL")
#! Record("MGNT:LI21:1:ALLKICKS",540,102,0,0,"MGNT:LI21:1:ALLKICKS")
#! Field("MGNT:LI21:1:ALLKICKS.VAL",16777215,0,"MGNT:LI21:1:ALLKICKS.VAL")
#! Field("MGNT:LI21:1:ALLKICKS.FLNK",16777215,1,"MGNT:LI21:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:LI21:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:LI21:1:SEXTSWITCH")
}

record(seq, "MGNT:LI21:1:SEXTSWITCH") {
  field(DOL1, "MGNT:LI21:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:LI21:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI21:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI21:1:SEXTCTRL")
}

record(seq, "MGNT:LI21:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:LI21:1:ALLSTAR")
  field(LNK1, "MGNT:LI21:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:LI21:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI21:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI21:1:SEXTCTRL",20,10,0,0,"MGNT:LI21:1:SEXTCTRL")
#! Field("MGNT:LI21:1:SEXTCTRL.FLNK",16777215,1,"MGNT:LI21:1:SEXTCTRL.FLNK")
#! Link("MGNT:LI21:1:SEXTCTRL.FLNK","MGNT:LI21:1:SEXTSWITCH")
#! Field("MGNT:LI21:1:SEXTCTRL.FFVL",16777215,1,"MGNT:LI21:1:SEXTCTRL.FFVL")
#! Record("MGNT:LI21:1:SEXTSWITCH",460,322,0,0,"MGNT:LI21:1:SEXTSWITCH")
#! Field("MGNT:LI21:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:LI21:1:SEXTSWITCH.DOL1")
#! Link("MGNT:LI21:1:SEXTSWITCH.DOL1","MGNT:LI21:1:SEXTCTRL.FFVL")
#! Field("MGNT:LI21:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:LI21:1:SEXTSWITCH.LNK1")
#! Field("MGNT:LI21:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:LI21:1:SEXTSWITCH.FLNK")
#! Record("MGNT:LI21:1:ALLSEXTSGO",240,96,0,0,"MGNT:LI21:1:ALLSEXTSGO")
#! Field("MGNT:LI21:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:LI21:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:LI21:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:LI21:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:LI21:1:ALLSEXTSGO.LNK1","MGNT:LI21:1:ALLSEXTS.VAL")
#! Record("MGNT:LI21:1:ALLSEXTS",540,102,0,0,"MGNT:LI21:1:ALLSEXTS")
#! Field("MGNT:LI21:1:ALLSEXTS.VAL",16777215,0,"MGNT:LI21:1:ALLSEXTS.VAL")
#! Field("MGNT:LI21:1:ALLSEXTS.FLNK",16777215,1,"MGNT:LI21:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:LI22:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:LI22:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:LI22:1:CTRL CA PP")
  field(LNK2, "MGNT:LI22:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:LI22:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:LI22:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:LI22:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:LI22:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:LI22:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:LI22:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:LI22:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:LI22:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:LI22:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:LI22:1:ALLSWITCH")
}

record(seq, "MGNT:LI22:1:ALLSWITCH") {
  field(DOL1, "MGNT:LI22:1:CTRL.FFVL")
  field(LNK1, "MGNT:LI22:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI22:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI22:1:CTRL")
}

record(bo, "MGNT:LI22:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:LI22:1:ALLSTARGO")
}

record(fanout, "MGNT:LI22:1:ALLSTARGO") {
  field(LNK1, "MGNT:LI22:1:ALLBENDSGO")
  field(LNK2, "MGNT:LI22:1:ALLBTRMSGO")
  field(LNK3, "MGNT:LI22:1:ALLLGPSSGO")
  field(LNK4, "MGNT:LI22:1:ALLQUADSGO")
  field(LNK5, "MGNT:LI22:1:ALLXCORSGO")
  field(LNK6, "MGNT:LI22:1:ALLYCORSGO")
  field(FLNK, "MGNT:LI22:1:ALLSTARGO_2")
}
record(fanout, "MGNT:LI22:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:LI22:1:ALLSOLNSGO")
  field(LNK2, "MGNT:LI22:1:ALLKICKSGO")
  field(LNK3, "MGNT:LI22:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:LI22:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:LI22:1:BENDSWITCH")
}

record(seq, "MGNT:LI22:1:BENDSWITCH") {
  field(DOL1, "MGNT:LI22:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:LI22:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI22:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI22:1:BENDCTRL")
}

record(seq, "MGNT:LI22:1:ALLBENDSGO") {
  field(DOL1, "MGNT:LI22:1:ALLSTAR")
  field(LNK1, "MGNT:LI22:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:LI22:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI22:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI22:1:BENDCTRL",20,10,0,0,"MGNT:LI22:1:BENDCTRL")
#! Field("MGNT:LI22:1:BENDCTRL.FLNK",16777215,1,"MGNT:LI22:1:BENDCTRL.FLNK")
#! Link("MGNT:LI22:1:BENDCTRL.FLNK","MGNT:LI22:1:BENDSWITCH")
#! Field("MGNT:LI22:1:BENDCTRL.FFVL",16777215,1,"MGNT:LI22:1:BENDCTRL.FFVL")
#! Record("MGNT:LI22:1:BENDSWITCH",460,322,0,0,"MGNT:LI22:1:BENDSWITCH")
#! Field("MGNT:LI22:1:BENDSWITCH.DOL1",16777215,0,"MGNT:LI22:1:BENDSWITCH.DOL1")
#! Link("MGNT:LI22:1:BENDSWITCH.DOL1","MGNT:LI22:1:BENDCTRL.FFVL")
#! Field("MGNT:LI22:1:BENDSWITCH.LNK1",16777215,1,"MGNT:LI22:1:BENDSWITCH.LNK1")
#! Field("MGNT:LI22:1:BENDSWITCH.FLNK",16777215,1,"MGNT:LI22:1:BENDSWITCH.FLNK")
#! Record("MGNT:LI22:1:ALLBENDSGO",240,96,0,0,"MGNT:LI22:1:ALLBENDSGO")
#! Field("MGNT:LI22:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:LI22:1:ALLBENDSGO.DOL1")
#! Field("MGNT:LI22:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:LI22:1:ALLBENDSGO.LNK1")
#! Link("MGNT:LI22:1:ALLBENDSGO.LNK1","MGNT:LI22:1:ALLBENDS.VAL")
#! Record("MGNT:LI22:1:ALLBENDS",540,102,0,0,"MGNT:LI22:1:ALLBENDS")
#! Field("MGNT:LI22:1:ALLBENDS.VAL",16777215,0,"MGNT:LI22:1:ALLBENDS.VAL")
#! Field("MGNT:LI22:1:ALLBENDS.FLNK",16777215,1,"MGNT:LI22:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:LI22:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI22:1:BTRMSWITCH")
}

record(seq, "MGNT:LI22:1:BTRMSWITCH") {
  field(DOL1, "MGNT:LI22:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:LI22:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI22:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI22:1:BTRMCTRL")
}

record(seq, "MGNT:LI22:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:LI22:1:ALLSTAR")
  field(LNK1, "MGNT:LI22:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:LI22:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI22:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI22:1:BTRMCTRL",20,10,0,0,"MGNT:LI22:1:BTRMCTRL")
#! Field("MGNT:LI22:1:BTRMCTRL.FLNK",16777215,1,"MGNT:LI22:1:BTRMCTRL.FLNK")
#! Link("MGNT:LI22:1:BTRMCTRL.FLNK","MGNT:LI22:1:BTRMSWITCH")
#! Field("MGNT:LI22:1:BTRMCTRL.FFVL",16777215,1,"MGNT:LI22:1:BTRMCTRL.FFVL")
#! Record("MGNT:LI22:1:BTRMSWITCH",460,322,0,0,"MGNT:LI22:1:BTRMSWITCH")
#! Field("MGNT:LI22:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:LI22:1:BTRMSWITCH.DOL1")
#! Link("MGNT:LI22:1:BTRMSWITCH.DOL1","MGNT:LI22:1:BTRMCTRL.FFVL")
#! Field("MGNT:LI22:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:LI22:1:BTRMSWITCH.LNK1")
#! Field("MGNT:LI22:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:LI22:1:BTRMSWITCH.FLNK")
#! Record("MGNT:LI22:1:ALLBTRMSGO",240,96,0,0,"MGNT:LI22:1:ALLBTRMSGO")
#! Field("MGNT:LI22:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:LI22:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:LI22:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:LI22:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:LI22:1:ALLBTRMSGO.LNK1","MGNT:LI22:1:ALLBTRMS.VAL")
#! Record("MGNT:LI22:1:ALLBTRMS",540,102,0,0,"MGNT:LI22:1:ALLBTRMS")
#! Field("MGNT:LI22:1:ALLBTRMS.VAL",16777215,0,"MGNT:LI22:1:ALLBTRMS.VAL")
#! Field("MGNT:LI22:1:ALLBTRMS.FLNK",16777215,1,"MGNT:LI22:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:LI22:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI22:1:LGPSSWITCH")
}

record(seq, "MGNT:LI22:1:LGPSSWITCH") {
  field(DOL1, "MGNT:LI22:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:LI22:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI22:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI22:1:LGPSCTRL")
}

record(seq, "MGNT:LI22:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:LI22:1:ALLSTAR")
  field(LNK1, "MGNT:LI22:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:LI22:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI22:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI22:1:LGPSCTRL",20,10,0,0,"MGNT:LI22:1:LGPSCTRL")
#! Field("MGNT:LI22:1:LGPSCTRL.FLNK",16777215,1,"MGNT:LI22:1:LGPSCTRL.FLNK")
#! Link("MGNT:LI22:1:LGPSCTRL.FLNK","MGNT:LI22:1:LGPSSWITCH")
#! Field("MGNT:LI22:1:LGPSCTRL.FFVL",16777215,1,"MGNT:LI22:1:LGPSCTRL.FFVL")
#! Record("MGNT:LI22:1:LGPSSWITCH",460,322,0,0,"MGNT:LI22:1:LGPSSWITCH")
#! Field("MGNT:LI22:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:LI22:1:LGPSSWITCH.DOL1")
#! Link("MGNT:LI22:1:LGPSSWITCH.DOL1","MGNT:LI22:1:LGPSCTRL.FFVL")
#! Field("MGNT:LI22:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:LI22:1:LGPSSWITCH.LNK1")
#! Field("MGNT:LI22:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:LI22:1:LGPSSWITCH.FLNK")
#! Record("MGNT:LI22:1:ALLLGPSSGO",240,96,0,0,"MGNT:LI22:1:ALLLGPSSGO")
#! Field("MGNT:LI22:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:LI22:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:LI22:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:LI22:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:LI22:1:ALLLGPSSGO.LNK1","MGNT:LI22:1:ALLLGPSS.VAL")
#! Record("MGNT:LI22:1:ALLLGPSS",540,102,0,0,"MGNT:LI22:1:ALLLGPSS")
#! Field("MGNT:LI22:1:ALLLGPSS.VAL",16777215,0,"MGNT:LI22:1:ALLLGPSS.VAL")
#! Field("MGNT:LI22:1:ALLLGPSS.FLNK",16777215,1,"MGNT:LI22:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:LI22:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:LI22:1:QUADSWITCH")
}

record(seq, "MGNT:LI22:1:QUADSWITCH") {
  field(DOL1, "MGNT:LI22:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:LI22:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI22:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI22:1:QUADCTRL")
}

record(seq, "MGNT:LI22:1:ALLQUADSGO") {
  field(DOL1, "MGNT:LI22:1:ALLSTAR")
  field(LNK1, "MGNT:LI22:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:LI22:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI22:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI22:1:QUADCTRL",20,10,0,0,"MGNT:LI22:1:QUADCTRL")
#! Field("MGNT:LI22:1:QUADCTRL.FLNK",16777215,1,"MGNT:LI22:1:QUADCTRL.FLNK")
#! Link("MGNT:LI22:1:QUADCTRL.FLNK","MGNT:LI22:1:QUADSWITCH")
#! Field("MGNT:LI22:1:QUADCTRL.FFVL",16777215,1,"MGNT:LI22:1:QUADCTRL.FFVL")
#! Record("MGNT:LI22:1:QUADSWITCH",460,322,0,0,"MGNT:LI22:1:QUADSWITCH")
#! Field("MGNT:LI22:1:QUADSWITCH.DOL1",16777215,0,"MGNT:LI22:1:QUADSWITCH.DOL1")
#! Link("MGNT:LI22:1:QUADSWITCH.DOL1","MGNT:LI22:1:QUADCTRL.FFVL")
#! Field("MGNT:LI22:1:QUADSWITCH.LNK1",16777215,1,"MGNT:LI22:1:QUADSWITCH.LNK1")
#! Field("MGNT:LI22:1:QUADSWITCH.FLNK",16777215,1,"MGNT:LI22:1:QUADSWITCH.FLNK")
#! Record("MGNT:LI22:1:ALLQUADSGO",240,96,0,0,"MGNT:LI22:1:ALLQUADSGO")
#! Field("MGNT:LI22:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:LI22:1:ALLQUADSGO.DOL1")
#! Field("MGNT:LI22:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:LI22:1:ALLQUADSGO.LNK1")
#! Link("MGNT:LI22:1:ALLQUADSGO.LNK1","MGNT:LI22:1:ALLQUADS.VAL")
#! Record("MGNT:LI22:1:ALLQUADS",540,102,0,0,"MGNT:LI22:1:ALLQUADS")
#! Field("MGNT:LI22:1:ALLQUADS.VAL",16777215,0,"MGNT:LI22:1:ALLQUADS.VAL")
#! Field("MGNT:LI22:1:ALLQUADS.FLNK",16777215,1,"MGNT:LI22:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:LI22:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:LI22:1:XCORSWITCH")
}

record(seq, "MGNT:LI22:1:XCORSWITCH") {
  field(DOL1, "MGNT:LI22:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:LI22:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI22:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI22:1:XCORCTRL")
}

record(seq, "MGNT:LI22:1:ALLXCORSGO") {
  field(DOL1, "MGNT:LI22:1:ALLSTAR")
  field(LNK1, "MGNT:LI22:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:LI22:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI22:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI22:1:XCORCTRL",20,10,0,0,"MGNT:LI22:1:XCORCTRL")
#! Field("MGNT:LI22:1:XCORCTRL.FLNK",16777215,1,"MGNT:LI22:1:XCORCTRL.FLNK")
#! Link("MGNT:LI22:1:XCORCTRL.FLNK","MGNT:LI22:1:XCORSWITCH")
#! Field("MGNT:LI22:1:XCORCTRL.FFVL",16777215,1,"MGNT:LI22:1:XCORCTRL.FFVL")
#! Record("MGNT:LI22:1:XCORSWITCH",460,322,0,0,"MGNT:LI22:1:XCORSWITCH")
#! Field("MGNT:LI22:1:XCORSWITCH.DOL1",16777215,0,"MGNT:LI22:1:XCORSWITCH.DOL1")
#! Link("MGNT:LI22:1:XCORSWITCH.DOL1","MGNT:LI22:1:XCORCTRL.FFVL")
#! Field("MGNT:LI22:1:XCORSWITCH.LNK1",16777215,1,"MGNT:LI22:1:XCORSWITCH.LNK1")
#! Field("MGNT:LI22:1:XCORSWITCH.FLNK",16777215,1,"MGNT:LI22:1:XCORSWITCH.FLNK")
#! Record("MGNT:LI22:1:ALLXCORSGO",240,96,0,0,"MGNT:LI22:1:ALLXCORSGO")
#! Field("MGNT:LI22:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:LI22:1:ALLXCORSGO.DOL1")
#! Field("MGNT:LI22:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:LI22:1:ALLXCORSGO.LNK1")
#! Link("MGNT:LI22:1:ALLXCORSGO.LNK1","MGNT:LI22:1:ALLXCORS.VAL")
#! Record("MGNT:LI22:1:ALLXCORS",540,102,0,0,"MGNT:LI22:1:ALLXCORS")
#! Field("MGNT:LI22:1:ALLXCORS.VAL",16777215,0,"MGNT:LI22:1:ALLXCORS.VAL")
#! Field("MGNT:LI22:1:ALLXCORS.FLNK",16777215,1,"MGNT:LI22:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:LI22:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:LI22:1:YCORSWITCH")
}

record(seq, "MGNT:LI22:1:YCORSWITCH") {
  field(DOL1, "MGNT:LI22:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:LI22:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI22:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI22:1:YCORCTRL")
}

record(seq, "MGNT:LI22:1:ALLYCORSGO") {
  field(DOL1, "MGNT:LI22:1:ALLSTAR")
  field(LNK1, "MGNT:LI22:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:LI22:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI22:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI22:1:YCORCTRL",20,10,0,0,"MGNT:LI22:1:YCORCTRL")
#! Field("MGNT:LI22:1:YCORCTRL.FLNK",16777215,1,"MGNT:LI22:1:YCORCTRL.FLNK")
#! Link("MGNT:LI22:1:YCORCTRL.FLNK","MGNT:LI22:1:YCORSWITCH")
#! Field("MGNT:LI22:1:YCORCTRL.FFVL",16777215,1,"MGNT:LI22:1:YCORCTRL.FFVL")
#! Record("MGNT:LI22:1:YCORSWITCH",460,322,0,0,"MGNT:LI22:1:YCORSWITCH")
#! Field("MGNT:LI22:1:YCORSWITCH.DOL1",16777215,0,"MGNT:LI22:1:YCORSWITCH.DOL1")
#! Link("MGNT:LI22:1:YCORSWITCH.DOL1","MGNT:LI22:1:YCORCTRL.FFVL")
#! Field("MGNT:LI22:1:YCORSWITCH.LNK1",16777215,1,"MGNT:LI22:1:YCORSWITCH.LNK1")
#! Field("MGNT:LI22:1:YCORSWITCH.FLNK",16777215,1,"MGNT:LI22:1:YCORSWITCH.FLNK")
#! Record("MGNT:LI22:1:ALLYCORSGO",240,96,0,0,"MGNT:LI22:1:ALLYCORSGO")
#! Field("MGNT:LI22:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:LI22:1:ALLYCORSGO.DOL1")
#! Field("MGNT:LI22:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:LI22:1:ALLYCORSGO.LNK1")
#! Link("MGNT:LI22:1:ALLYCORSGO.LNK1","MGNT:LI22:1:ALLYCORS.VAL")
#! Record("MGNT:LI22:1:ALLYCORS",540,102,0,0,"MGNT:LI22:1:ALLYCORS")
#! Field("MGNT:LI22:1:ALLYCORS.VAL",16777215,0,"MGNT:LI22:1:ALLYCORS.VAL")
#! Field("MGNT:LI22:1:ALLYCORS.FLNK",16777215,1,"MGNT:LI22:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:LI22:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:LI22:1:SOLNSWITCH")
}

record(seq, "MGNT:LI22:1:SOLNSWITCH") {
  field(DOL1, "MGNT:LI22:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:LI22:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI22:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI22:1:SOLNCTRL")
}

record(seq, "MGNT:LI22:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:LI22:1:ALLSTAR")
  field(LNK1, "MGNT:LI22:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:LI22:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI22:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI22:1:SOLNCTRL",20,10,0,0,"MGNT:LI22:1:SOLNCTRL")
#! Field("MGNT:LI22:1:SOLNCTRL.FLNK",16777215,1,"MGNT:LI22:1:SOLNCTRL.FLNK")
#! Link("MGNT:LI22:1:SOLNCTRL.FLNK","MGNT:LI22:1:SOLNSWITCH")
#! Field("MGNT:LI22:1:SOLNCTRL.FFVL",16777215,1,"MGNT:LI22:1:SOLNCTRL.FFVL")
#! Record("MGNT:LI22:1:SOLNSWITCH",460,322,0,0,"MGNT:LI22:1:SOLNSWITCH")
#! Field("MGNT:LI22:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:LI22:1:SOLNSWITCH.DOL1")
#! Link("MGNT:LI22:1:SOLNSWITCH.DOL1","MGNT:LI22:1:SOLNCTRL.FFVL")
#! Field("MGNT:LI22:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:LI22:1:SOLNSWITCH.LNK1")
#! Field("MGNT:LI22:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:LI22:1:SOLNSWITCH.FLNK")
#! Record("MGNT:LI22:1:ALLSOLNSGO",240,96,0,0,"MGNT:LI22:1:ALLSOLNSGO")
#! Field("MGNT:LI22:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:LI22:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:LI22:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:LI22:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:LI22:1:ALLSOLNSGO.LNK1","MGNT:LI22:1:ALLSOLNS.VAL")
#! Record("MGNT:LI22:1:ALLSOLNS",540,102,0,0,"MGNT:LI22:1:ALLSOLNS")
#! Field("MGNT:LI22:1:ALLSOLNS.VAL",16777215,0,"MGNT:LI22:1:ALLSOLNS.VAL")
#! Field("MGNT:LI22:1:ALLSOLNS.FLNK",16777215,1,"MGNT:LI22:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:LI22:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:LI22:1:KICKSWITCH")
}

record(seq, "MGNT:LI22:1:KICKSWITCH") {
  field(DOL1, "MGNT:LI22:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:LI22:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI22:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI22:1:KICKCTRL")
}

record(seq, "MGNT:LI22:1:ALLKICKSGO") {
  field(DOL1, "MGNT:LI22:1:ALLSTAR")
  field(LNK1, "MGNT:LI22:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:LI22:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI22:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI22:1:KICKCTRL",20,10,0,0,"MGNT:LI22:1:KICKCTRL")
#! Field("MGNT:LI22:1:KICKCTRL.FLNK",16777215,1,"MGNT:LI22:1:KICKCTRL.FLNK")
#! Link("MGNT:LI22:1:KICKCTRL.FLNK","MGNT:LI22:1:KICKSWITCH")
#! Field("MGNT:LI22:1:KICKCTRL.FFVL",16777215,1,"MGNT:LI22:1:KICKCTRL.FFVL")
#! Record("MGNT:LI22:1:KICKSWITCH",460,322,0,0,"MGNT:LI22:1:KICKSWITCH")
#! Field("MGNT:LI22:1:KICKSWITCH.DOL1",16777215,0,"MGNT:LI22:1:KICKSWITCH.DOL1")
#! Link("MGNT:LI22:1:KICKSWITCH.DOL1","MGNT:LI22:1:KICKCTRL.FFVL")
#! Field("MGNT:LI22:1:KICKSWITCH.LNK1",16777215,1,"MGNT:LI22:1:KICKSWITCH.LNK1")
#! Field("MGNT:LI22:1:KICKSWITCH.FLNK",16777215,1,"MGNT:LI22:1:KICKSWITCH.FLNK")
#! Record("MGNT:LI22:1:ALLKICKSGO",240,96,0,0,"MGNT:LI22:1:ALLKICKSGO")
#! Field("MGNT:LI22:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:LI22:1:ALLKICKSGO.DOL1")
#! Field("MGNT:LI22:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:LI22:1:ALLKICKSGO.LNK1")
#! Link("MGNT:LI22:1:ALLKICKSGO.LNK1","MGNT:LI22:1:ALLKICKS.VAL")
#! Record("MGNT:LI22:1:ALLKICKS",540,102,0,0,"MGNT:LI22:1:ALLKICKS")
#! Field("MGNT:LI22:1:ALLKICKS.VAL",16777215,0,"MGNT:LI22:1:ALLKICKS.VAL")
#! Field("MGNT:LI22:1:ALLKICKS.FLNK",16777215,1,"MGNT:LI22:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:LI22:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:LI22:1:SEXTSWITCH")
}

record(seq, "MGNT:LI22:1:SEXTSWITCH") {
  field(DOL1, "MGNT:LI22:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:LI22:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI22:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI22:1:SEXTCTRL")
}

record(seq, "MGNT:LI22:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:LI22:1:ALLSTAR")
  field(LNK1, "MGNT:LI22:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:LI22:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI22:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI22:1:SEXTCTRL",20,10,0,0,"MGNT:LI22:1:SEXTCTRL")
#! Field("MGNT:LI22:1:SEXTCTRL.FLNK",16777215,1,"MGNT:LI22:1:SEXTCTRL.FLNK")
#! Link("MGNT:LI22:1:SEXTCTRL.FLNK","MGNT:LI22:1:SEXTSWITCH")
#! Field("MGNT:LI22:1:SEXTCTRL.FFVL",16777215,1,"MGNT:LI22:1:SEXTCTRL.FFVL")
#! Record("MGNT:LI22:1:SEXTSWITCH",460,322,0,0,"MGNT:LI22:1:SEXTSWITCH")
#! Field("MGNT:LI22:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:LI22:1:SEXTSWITCH.DOL1")
#! Link("MGNT:LI22:1:SEXTSWITCH.DOL1","MGNT:LI22:1:SEXTCTRL.FFVL")
#! Field("MGNT:LI22:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:LI22:1:SEXTSWITCH.LNK1")
#! Field("MGNT:LI22:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:LI22:1:SEXTSWITCH.FLNK")
#! Record("MGNT:LI22:1:ALLSEXTSGO",240,96,0,0,"MGNT:LI22:1:ALLSEXTSGO")
#! Field("MGNT:LI22:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:LI22:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:LI22:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:LI22:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:LI22:1:ALLSEXTSGO.LNK1","MGNT:LI22:1:ALLSEXTS.VAL")
#! Record("MGNT:LI22:1:ALLSEXTS",540,102,0,0,"MGNT:LI22:1:ALLSEXTS")
#! Field("MGNT:LI22:1:ALLSEXTS.VAL",16777215,0,"MGNT:LI22:1:ALLSEXTS.VAL")
#! Field("MGNT:LI22:1:ALLSEXTS.FLNK",16777215,1,"MGNT:LI22:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:LI24:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:LI24:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:LI24:1:CTRL CA PP")
  field(LNK2, "MGNT:LI24:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:LI24:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:LI24:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:LI24:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:LI24:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:LI24:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:LI24:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:LI24:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:LI24:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:LI24:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:LI24:1:ALLSWITCH")
}

record(seq, "MGNT:LI24:1:ALLSWITCH") {
  field(DOL1, "MGNT:LI24:1:CTRL.FFVL")
  field(LNK1, "MGNT:LI24:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI24:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI24:1:CTRL")
}

record(bo, "MGNT:LI24:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:LI24:1:ALLSTARGO")
}

record(fanout, "MGNT:LI24:1:ALLSTARGO") {
  field(LNK1, "MGNT:LI24:1:ALLBENDSGO")
  field(LNK2, "MGNT:LI24:1:ALLBTRMSGO")
  field(LNK3, "MGNT:LI24:1:ALLLGPSSGO")
  field(LNK4, "MGNT:LI24:1:ALLQUADSGO")
  field(LNK5, "MGNT:LI24:1:ALLXCORSGO")
  field(LNK6, "MGNT:LI24:1:ALLYCORSGO")
  field(FLNK, "MGNT:LI24:1:ALLSTARGO_2")
}
record(fanout, "MGNT:LI24:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:LI24:1:ALLSOLNSGO")
  field(LNK2, "MGNT:LI24:1:ALLKICKSGO")
  field(LNK3, "MGNT:LI24:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:LI24:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:LI24:1:BENDSWITCH")
}

record(seq, "MGNT:LI24:1:BENDSWITCH") {
  field(DOL1, "MGNT:LI24:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:LI24:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI24:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI24:1:BENDCTRL")
}

record(seq, "MGNT:LI24:1:ALLBENDSGO") {
  field(DOL1, "MGNT:LI24:1:ALLSTAR")
  field(LNK1, "MGNT:LI24:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:LI24:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI24:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI24:1:BENDCTRL",20,10,0,0,"MGNT:LI24:1:BENDCTRL")
#! Field("MGNT:LI24:1:BENDCTRL.FLNK",16777215,1,"MGNT:LI24:1:BENDCTRL.FLNK")
#! Link("MGNT:LI24:1:BENDCTRL.FLNK","MGNT:LI24:1:BENDSWITCH")
#! Field("MGNT:LI24:1:BENDCTRL.FFVL",16777215,1,"MGNT:LI24:1:BENDCTRL.FFVL")
#! Record("MGNT:LI24:1:BENDSWITCH",460,322,0,0,"MGNT:LI24:1:BENDSWITCH")
#! Field("MGNT:LI24:1:BENDSWITCH.DOL1",16777215,0,"MGNT:LI24:1:BENDSWITCH.DOL1")
#! Link("MGNT:LI24:1:BENDSWITCH.DOL1","MGNT:LI24:1:BENDCTRL.FFVL")
#! Field("MGNT:LI24:1:BENDSWITCH.LNK1",16777215,1,"MGNT:LI24:1:BENDSWITCH.LNK1")
#! Field("MGNT:LI24:1:BENDSWITCH.FLNK",16777215,1,"MGNT:LI24:1:BENDSWITCH.FLNK")
#! Record("MGNT:LI24:1:ALLBENDSGO",240,96,0,0,"MGNT:LI24:1:ALLBENDSGO")
#! Field("MGNT:LI24:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:LI24:1:ALLBENDSGO.DOL1")
#! Field("MGNT:LI24:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:LI24:1:ALLBENDSGO.LNK1")
#! Link("MGNT:LI24:1:ALLBENDSGO.LNK1","MGNT:LI24:1:ALLBENDS.VAL")
#! Record("MGNT:LI24:1:ALLBENDS",540,102,0,0,"MGNT:LI24:1:ALLBENDS")
#! Field("MGNT:LI24:1:ALLBENDS.VAL",16777215,0,"MGNT:LI24:1:ALLBENDS.VAL")
#! Field("MGNT:LI24:1:ALLBENDS.FLNK",16777215,1,"MGNT:LI24:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:LI24:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI24:1:BTRMSWITCH")
}

record(seq, "MGNT:LI24:1:BTRMSWITCH") {
  field(DOL1, "MGNT:LI24:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:LI24:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI24:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI24:1:BTRMCTRL")
}

record(seq, "MGNT:LI24:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:LI24:1:ALLSTAR")
  field(LNK1, "MGNT:LI24:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:LI24:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI24:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI24:1:BTRMCTRL",20,10,0,0,"MGNT:LI24:1:BTRMCTRL")
#! Field("MGNT:LI24:1:BTRMCTRL.FLNK",16777215,1,"MGNT:LI24:1:BTRMCTRL.FLNK")
#! Link("MGNT:LI24:1:BTRMCTRL.FLNK","MGNT:LI24:1:BTRMSWITCH")
#! Field("MGNT:LI24:1:BTRMCTRL.FFVL",16777215,1,"MGNT:LI24:1:BTRMCTRL.FFVL")
#! Record("MGNT:LI24:1:BTRMSWITCH",460,322,0,0,"MGNT:LI24:1:BTRMSWITCH")
#! Field("MGNT:LI24:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:LI24:1:BTRMSWITCH.DOL1")
#! Link("MGNT:LI24:1:BTRMSWITCH.DOL1","MGNT:LI24:1:BTRMCTRL.FFVL")
#! Field("MGNT:LI24:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:LI24:1:BTRMSWITCH.LNK1")
#! Field("MGNT:LI24:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:LI24:1:BTRMSWITCH.FLNK")
#! Record("MGNT:LI24:1:ALLBTRMSGO",240,96,0,0,"MGNT:LI24:1:ALLBTRMSGO")
#! Field("MGNT:LI24:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:LI24:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:LI24:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:LI24:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:LI24:1:ALLBTRMSGO.LNK1","MGNT:LI24:1:ALLBTRMS.VAL")
#! Record("MGNT:LI24:1:ALLBTRMS",540,102,0,0,"MGNT:LI24:1:ALLBTRMS")
#! Field("MGNT:LI24:1:ALLBTRMS.VAL",16777215,0,"MGNT:LI24:1:ALLBTRMS.VAL")
#! Field("MGNT:LI24:1:ALLBTRMS.FLNK",16777215,1,"MGNT:LI24:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:LI24:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI24:1:LGPSSWITCH")
}

record(seq, "MGNT:LI24:1:LGPSSWITCH") {
  field(DOL1, "MGNT:LI24:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:LI24:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI24:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI24:1:LGPSCTRL")
}

record(seq, "MGNT:LI24:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:LI24:1:ALLSTAR")
  field(LNK1, "MGNT:LI24:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:LI24:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI24:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI24:1:LGPSCTRL",20,10,0,0,"MGNT:LI24:1:LGPSCTRL")
#! Field("MGNT:LI24:1:LGPSCTRL.FLNK",16777215,1,"MGNT:LI24:1:LGPSCTRL.FLNK")
#! Link("MGNT:LI24:1:LGPSCTRL.FLNK","MGNT:LI24:1:LGPSSWITCH")
#! Field("MGNT:LI24:1:LGPSCTRL.FFVL",16777215,1,"MGNT:LI24:1:LGPSCTRL.FFVL")
#! Record("MGNT:LI24:1:LGPSSWITCH",460,322,0,0,"MGNT:LI24:1:LGPSSWITCH")
#! Field("MGNT:LI24:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:LI24:1:LGPSSWITCH.DOL1")
#! Link("MGNT:LI24:1:LGPSSWITCH.DOL1","MGNT:LI24:1:LGPSCTRL.FFVL")
#! Field("MGNT:LI24:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:LI24:1:LGPSSWITCH.LNK1")
#! Field("MGNT:LI24:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:LI24:1:LGPSSWITCH.FLNK")
#! Record("MGNT:LI24:1:ALLLGPSSGO",240,96,0,0,"MGNT:LI24:1:ALLLGPSSGO")
#! Field("MGNT:LI24:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:LI24:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:LI24:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:LI24:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:LI24:1:ALLLGPSSGO.LNK1","MGNT:LI24:1:ALLLGPSS.VAL")
#! Record("MGNT:LI24:1:ALLLGPSS",540,102,0,0,"MGNT:LI24:1:ALLLGPSS")
#! Field("MGNT:LI24:1:ALLLGPSS.VAL",16777215,0,"MGNT:LI24:1:ALLLGPSS.VAL")
#! Field("MGNT:LI24:1:ALLLGPSS.FLNK",16777215,1,"MGNT:LI24:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:LI24:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:LI24:1:QUADSWITCH")
}

record(seq, "MGNT:LI24:1:QUADSWITCH") {
  field(DOL1, "MGNT:LI24:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:LI24:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI24:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI24:1:QUADCTRL")
}

record(seq, "MGNT:LI24:1:ALLQUADSGO") {
  field(DOL1, "MGNT:LI24:1:ALLSTAR")
  field(LNK1, "MGNT:LI24:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:LI24:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI24:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI24:1:QUADCTRL",20,10,0,0,"MGNT:LI24:1:QUADCTRL")
#! Field("MGNT:LI24:1:QUADCTRL.FLNK",16777215,1,"MGNT:LI24:1:QUADCTRL.FLNK")
#! Link("MGNT:LI24:1:QUADCTRL.FLNK","MGNT:LI24:1:QUADSWITCH")
#! Field("MGNT:LI24:1:QUADCTRL.FFVL",16777215,1,"MGNT:LI24:1:QUADCTRL.FFVL")
#! Record("MGNT:LI24:1:QUADSWITCH",460,322,0,0,"MGNT:LI24:1:QUADSWITCH")
#! Field("MGNT:LI24:1:QUADSWITCH.DOL1",16777215,0,"MGNT:LI24:1:QUADSWITCH.DOL1")
#! Link("MGNT:LI24:1:QUADSWITCH.DOL1","MGNT:LI24:1:QUADCTRL.FFVL")
#! Field("MGNT:LI24:1:QUADSWITCH.LNK1",16777215,1,"MGNT:LI24:1:QUADSWITCH.LNK1")
#! Field("MGNT:LI24:1:QUADSWITCH.FLNK",16777215,1,"MGNT:LI24:1:QUADSWITCH.FLNK")
#! Record("MGNT:LI24:1:ALLQUADSGO",240,96,0,0,"MGNT:LI24:1:ALLQUADSGO")
#! Field("MGNT:LI24:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:LI24:1:ALLQUADSGO.DOL1")
#! Field("MGNT:LI24:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:LI24:1:ALLQUADSGO.LNK1")
#! Link("MGNT:LI24:1:ALLQUADSGO.LNK1","MGNT:LI24:1:ALLQUADS.VAL")
#! Record("MGNT:LI24:1:ALLQUADS",540,102,0,0,"MGNT:LI24:1:ALLQUADS")
#! Field("MGNT:LI24:1:ALLQUADS.VAL",16777215,0,"MGNT:LI24:1:ALLQUADS.VAL")
#! Field("MGNT:LI24:1:ALLQUADS.FLNK",16777215,1,"MGNT:LI24:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:LI24:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:LI24:1:XCORSWITCH")
}

record(seq, "MGNT:LI24:1:XCORSWITCH") {
  field(DOL1, "MGNT:LI24:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:LI24:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI24:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI24:1:XCORCTRL")
}

record(seq, "MGNT:LI24:1:ALLXCORSGO") {
  field(DOL1, "MGNT:LI24:1:ALLSTAR")
  field(LNK1, "MGNT:LI24:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:LI24:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI24:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI24:1:XCORCTRL",20,10,0,0,"MGNT:LI24:1:XCORCTRL")
#! Field("MGNT:LI24:1:XCORCTRL.FLNK",16777215,1,"MGNT:LI24:1:XCORCTRL.FLNK")
#! Link("MGNT:LI24:1:XCORCTRL.FLNK","MGNT:LI24:1:XCORSWITCH")
#! Field("MGNT:LI24:1:XCORCTRL.FFVL",16777215,1,"MGNT:LI24:1:XCORCTRL.FFVL")
#! Record("MGNT:LI24:1:XCORSWITCH",460,322,0,0,"MGNT:LI24:1:XCORSWITCH")
#! Field("MGNT:LI24:1:XCORSWITCH.DOL1",16777215,0,"MGNT:LI24:1:XCORSWITCH.DOL1")
#! Link("MGNT:LI24:1:XCORSWITCH.DOL1","MGNT:LI24:1:XCORCTRL.FFVL")
#! Field("MGNT:LI24:1:XCORSWITCH.LNK1",16777215,1,"MGNT:LI24:1:XCORSWITCH.LNK1")
#! Field("MGNT:LI24:1:XCORSWITCH.FLNK",16777215,1,"MGNT:LI24:1:XCORSWITCH.FLNK")
#! Record("MGNT:LI24:1:ALLXCORSGO",240,96,0,0,"MGNT:LI24:1:ALLXCORSGO")
#! Field("MGNT:LI24:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:LI24:1:ALLXCORSGO.DOL1")
#! Field("MGNT:LI24:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:LI24:1:ALLXCORSGO.LNK1")
#! Link("MGNT:LI24:1:ALLXCORSGO.LNK1","MGNT:LI24:1:ALLXCORS.VAL")
#! Record("MGNT:LI24:1:ALLXCORS",540,102,0,0,"MGNT:LI24:1:ALLXCORS")
#! Field("MGNT:LI24:1:ALLXCORS.VAL",16777215,0,"MGNT:LI24:1:ALLXCORS.VAL")
#! Field("MGNT:LI24:1:ALLXCORS.FLNK",16777215,1,"MGNT:LI24:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:LI24:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:LI24:1:YCORSWITCH")
}

record(seq, "MGNT:LI24:1:YCORSWITCH") {
  field(DOL1, "MGNT:LI24:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:LI24:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI24:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI24:1:YCORCTRL")
}

record(seq, "MGNT:LI24:1:ALLYCORSGO") {
  field(DOL1, "MGNT:LI24:1:ALLSTAR")
  field(LNK1, "MGNT:LI24:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:LI24:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI24:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI24:1:YCORCTRL",20,10,0,0,"MGNT:LI24:1:YCORCTRL")
#! Field("MGNT:LI24:1:YCORCTRL.FLNK",16777215,1,"MGNT:LI24:1:YCORCTRL.FLNK")
#! Link("MGNT:LI24:1:YCORCTRL.FLNK","MGNT:LI24:1:YCORSWITCH")
#! Field("MGNT:LI24:1:YCORCTRL.FFVL",16777215,1,"MGNT:LI24:1:YCORCTRL.FFVL")
#! Record("MGNT:LI24:1:YCORSWITCH",460,322,0,0,"MGNT:LI24:1:YCORSWITCH")
#! Field("MGNT:LI24:1:YCORSWITCH.DOL1",16777215,0,"MGNT:LI24:1:YCORSWITCH.DOL1")
#! Link("MGNT:LI24:1:YCORSWITCH.DOL1","MGNT:LI24:1:YCORCTRL.FFVL")
#! Field("MGNT:LI24:1:YCORSWITCH.LNK1",16777215,1,"MGNT:LI24:1:YCORSWITCH.LNK1")
#! Field("MGNT:LI24:1:YCORSWITCH.FLNK",16777215,1,"MGNT:LI24:1:YCORSWITCH.FLNK")
#! Record("MGNT:LI24:1:ALLYCORSGO",240,96,0,0,"MGNT:LI24:1:ALLYCORSGO")
#! Field("MGNT:LI24:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:LI24:1:ALLYCORSGO.DOL1")
#! Field("MGNT:LI24:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:LI24:1:ALLYCORSGO.LNK1")
#! Link("MGNT:LI24:1:ALLYCORSGO.LNK1","MGNT:LI24:1:ALLYCORS.VAL")
#! Record("MGNT:LI24:1:ALLYCORS",540,102,0,0,"MGNT:LI24:1:ALLYCORS")
#! Field("MGNT:LI24:1:ALLYCORS.VAL",16777215,0,"MGNT:LI24:1:ALLYCORS.VAL")
#! Field("MGNT:LI24:1:ALLYCORS.FLNK",16777215,1,"MGNT:LI24:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:LI24:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:LI24:1:SOLNSWITCH")
}

record(seq, "MGNT:LI24:1:SOLNSWITCH") {
  field(DOL1, "MGNT:LI24:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:LI24:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI24:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI24:1:SOLNCTRL")
}

record(seq, "MGNT:LI24:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:LI24:1:ALLSTAR")
  field(LNK1, "MGNT:LI24:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:LI24:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI24:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI24:1:SOLNCTRL",20,10,0,0,"MGNT:LI24:1:SOLNCTRL")
#! Field("MGNT:LI24:1:SOLNCTRL.FLNK",16777215,1,"MGNT:LI24:1:SOLNCTRL.FLNK")
#! Link("MGNT:LI24:1:SOLNCTRL.FLNK","MGNT:LI24:1:SOLNSWITCH")
#! Field("MGNT:LI24:1:SOLNCTRL.FFVL",16777215,1,"MGNT:LI24:1:SOLNCTRL.FFVL")
#! Record("MGNT:LI24:1:SOLNSWITCH",460,322,0,0,"MGNT:LI24:1:SOLNSWITCH")
#! Field("MGNT:LI24:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:LI24:1:SOLNSWITCH.DOL1")
#! Link("MGNT:LI24:1:SOLNSWITCH.DOL1","MGNT:LI24:1:SOLNCTRL.FFVL")
#! Field("MGNT:LI24:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:LI24:1:SOLNSWITCH.LNK1")
#! Field("MGNT:LI24:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:LI24:1:SOLNSWITCH.FLNK")
#! Record("MGNT:LI24:1:ALLSOLNSGO",240,96,0,0,"MGNT:LI24:1:ALLSOLNSGO")
#! Field("MGNT:LI24:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:LI24:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:LI24:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:LI24:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:LI24:1:ALLSOLNSGO.LNK1","MGNT:LI24:1:ALLSOLNS.VAL")
#! Record("MGNT:LI24:1:ALLSOLNS",540,102,0,0,"MGNT:LI24:1:ALLSOLNS")
#! Field("MGNT:LI24:1:ALLSOLNS.VAL",16777215,0,"MGNT:LI24:1:ALLSOLNS.VAL")
#! Field("MGNT:LI24:1:ALLSOLNS.FLNK",16777215,1,"MGNT:LI24:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:LI24:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:LI24:1:KICKSWITCH")
}

record(seq, "MGNT:LI24:1:KICKSWITCH") {
  field(DOL1, "MGNT:LI24:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:LI24:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI24:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI24:1:KICKCTRL")
}

record(seq, "MGNT:LI24:1:ALLKICKSGO") {
  field(DOL1, "MGNT:LI24:1:ALLSTAR")
  field(LNK1, "MGNT:LI24:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:LI24:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI24:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI24:1:KICKCTRL",20,10,0,0,"MGNT:LI24:1:KICKCTRL")
#! Field("MGNT:LI24:1:KICKCTRL.FLNK",16777215,1,"MGNT:LI24:1:KICKCTRL.FLNK")
#! Link("MGNT:LI24:1:KICKCTRL.FLNK","MGNT:LI24:1:KICKSWITCH")
#! Field("MGNT:LI24:1:KICKCTRL.FFVL",16777215,1,"MGNT:LI24:1:KICKCTRL.FFVL")
#! Record("MGNT:LI24:1:KICKSWITCH",460,322,0,0,"MGNT:LI24:1:KICKSWITCH")
#! Field("MGNT:LI24:1:KICKSWITCH.DOL1",16777215,0,"MGNT:LI24:1:KICKSWITCH.DOL1")
#! Link("MGNT:LI24:1:KICKSWITCH.DOL1","MGNT:LI24:1:KICKCTRL.FFVL")
#! Field("MGNT:LI24:1:KICKSWITCH.LNK1",16777215,1,"MGNT:LI24:1:KICKSWITCH.LNK1")
#! Field("MGNT:LI24:1:KICKSWITCH.FLNK",16777215,1,"MGNT:LI24:1:KICKSWITCH.FLNK")
#! Record("MGNT:LI24:1:ALLKICKSGO",240,96,0,0,"MGNT:LI24:1:ALLKICKSGO")
#! Field("MGNT:LI24:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:LI24:1:ALLKICKSGO.DOL1")
#! Field("MGNT:LI24:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:LI24:1:ALLKICKSGO.LNK1")
#! Link("MGNT:LI24:1:ALLKICKSGO.LNK1","MGNT:LI24:1:ALLKICKS.VAL")
#! Record("MGNT:LI24:1:ALLKICKS",540,102,0,0,"MGNT:LI24:1:ALLKICKS")
#! Field("MGNT:LI24:1:ALLKICKS.VAL",16777215,0,"MGNT:LI24:1:ALLKICKS.VAL")
#! Field("MGNT:LI24:1:ALLKICKS.FLNK",16777215,1,"MGNT:LI24:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:LI24:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:LI24:1:SEXTSWITCH")
}

record(seq, "MGNT:LI24:1:SEXTSWITCH") {
  field(DOL1, "MGNT:LI24:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:LI24:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI24:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI24:1:SEXTCTRL")
}

record(seq, "MGNT:LI24:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:LI24:1:ALLSTAR")
  field(LNK1, "MGNT:LI24:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:LI24:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI24:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI24:1:SEXTCTRL",20,10,0,0,"MGNT:LI24:1:SEXTCTRL")
#! Field("MGNT:LI24:1:SEXTCTRL.FLNK",16777215,1,"MGNT:LI24:1:SEXTCTRL.FLNK")
#! Link("MGNT:LI24:1:SEXTCTRL.FLNK","MGNT:LI24:1:SEXTSWITCH")
#! Field("MGNT:LI24:1:SEXTCTRL.FFVL",16777215,1,"MGNT:LI24:1:SEXTCTRL.FFVL")
#! Record("MGNT:LI24:1:SEXTSWITCH",460,322,0,0,"MGNT:LI24:1:SEXTSWITCH")
#! Field("MGNT:LI24:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:LI24:1:SEXTSWITCH.DOL1")
#! Link("MGNT:LI24:1:SEXTSWITCH.DOL1","MGNT:LI24:1:SEXTCTRL.FFVL")
#! Field("MGNT:LI24:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:LI24:1:SEXTSWITCH.LNK1")
#! Field("MGNT:LI24:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:LI24:1:SEXTSWITCH.FLNK")
#! Record("MGNT:LI24:1:ALLSEXTSGO",240,96,0,0,"MGNT:LI24:1:ALLSEXTSGO")
#! Field("MGNT:LI24:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:LI24:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:LI24:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:LI24:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:LI24:1:ALLSEXTSGO.LNK1","MGNT:LI24:1:ALLSEXTS.VAL")
#! Record("MGNT:LI24:1:ALLSEXTS",540,102,0,0,"MGNT:LI24:1:ALLSEXTS")
#! Field("MGNT:LI24:1:ALLSEXTS.VAL",16777215,0,"MGNT:LI24:1:ALLSEXTS.VAL")
#! Field("MGNT:LI24:1:ALLSEXTS.FLNK",16777215,1,"MGNT:LI24:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:LI30:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:LI30:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:LI30:1:CTRL CA PP")
  field(LNK2, "MGNT:LI30:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:LI30:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:LI30:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:LI30:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:LI30:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:LI30:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:LI30:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:LI30:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:LI30:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:LI30:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:LI30:1:ALLSWITCH")
}

record(seq, "MGNT:LI30:1:ALLSWITCH") {
  field(DOL1, "MGNT:LI30:1:CTRL.FFVL")
  field(LNK1, "MGNT:LI30:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI30:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI30:1:CTRL")
}

record(bo, "MGNT:LI30:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:LI30:1:ALLSTARGO")
}

record(fanout, "MGNT:LI30:1:ALLSTARGO") {
  field(LNK1, "MGNT:LI30:1:ALLBENDSGO")
  field(LNK2, "MGNT:LI30:1:ALLBTRMSGO")
  field(LNK3, "MGNT:LI30:1:ALLLGPSSGO")
  field(LNK4, "MGNT:LI30:1:ALLQUADSGO")
  field(LNK5, "MGNT:LI30:1:ALLXCORSGO")
  field(LNK6, "MGNT:LI30:1:ALLYCORSGO")
  field(FLNK, "MGNT:LI30:1:ALLSTARGO_2")
}
record(fanout, "MGNT:LI30:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:LI30:1:ALLSOLNSGO")
  field(LNK2, "MGNT:LI30:1:ALLKICKSGO")
  field(LNK3, "MGNT:LI30:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:LI30:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:LI30:1:BENDSWITCH")
}

record(seq, "MGNT:LI30:1:BENDSWITCH") {
  field(DOL1, "MGNT:LI30:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:LI30:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI30:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI30:1:BENDCTRL")
}

record(seq, "MGNT:LI30:1:ALLBENDSGO") {
  field(DOL1, "MGNT:LI30:1:ALLSTAR")
  field(LNK1, "MGNT:LI30:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:LI30:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI30:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI30:1:BENDCTRL",20,10,0,0,"MGNT:LI30:1:BENDCTRL")
#! Field("MGNT:LI30:1:BENDCTRL.FLNK",16777215,1,"MGNT:LI30:1:BENDCTRL.FLNK")
#! Link("MGNT:LI30:1:BENDCTRL.FLNK","MGNT:LI30:1:BENDSWITCH")
#! Field("MGNT:LI30:1:BENDCTRL.FFVL",16777215,1,"MGNT:LI30:1:BENDCTRL.FFVL")
#! Record("MGNT:LI30:1:BENDSWITCH",460,322,0,0,"MGNT:LI30:1:BENDSWITCH")
#! Field("MGNT:LI30:1:BENDSWITCH.DOL1",16777215,0,"MGNT:LI30:1:BENDSWITCH.DOL1")
#! Link("MGNT:LI30:1:BENDSWITCH.DOL1","MGNT:LI30:1:BENDCTRL.FFVL")
#! Field("MGNT:LI30:1:BENDSWITCH.LNK1",16777215,1,"MGNT:LI30:1:BENDSWITCH.LNK1")
#! Field("MGNT:LI30:1:BENDSWITCH.FLNK",16777215,1,"MGNT:LI30:1:BENDSWITCH.FLNK")
#! Record("MGNT:LI30:1:ALLBENDSGO",240,96,0,0,"MGNT:LI30:1:ALLBENDSGO")
#! Field("MGNT:LI30:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:LI30:1:ALLBENDSGO.DOL1")
#! Field("MGNT:LI30:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:LI30:1:ALLBENDSGO.LNK1")
#! Link("MGNT:LI30:1:ALLBENDSGO.LNK1","MGNT:LI30:1:ALLBENDS.VAL")
#! Record("MGNT:LI30:1:ALLBENDS",540,102,0,0,"MGNT:LI30:1:ALLBENDS")
#! Field("MGNT:LI30:1:ALLBENDS.VAL",16777215,0,"MGNT:LI30:1:ALLBENDS.VAL")
#! Field("MGNT:LI30:1:ALLBENDS.FLNK",16777215,1,"MGNT:LI30:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:LI30:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI30:1:BTRMSWITCH")
}

record(seq, "MGNT:LI30:1:BTRMSWITCH") {
  field(DOL1, "MGNT:LI30:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:LI30:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI30:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI30:1:BTRMCTRL")
}

record(seq, "MGNT:LI30:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:LI30:1:ALLSTAR")
  field(LNK1, "MGNT:LI30:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:LI30:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI30:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI30:1:BTRMCTRL",20,10,0,0,"MGNT:LI30:1:BTRMCTRL")
#! Field("MGNT:LI30:1:BTRMCTRL.FLNK",16777215,1,"MGNT:LI30:1:BTRMCTRL.FLNK")
#! Link("MGNT:LI30:1:BTRMCTRL.FLNK","MGNT:LI30:1:BTRMSWITCH")
#! Field("MGNT:LI30:1:BTRMCTRL.FFVL",16777215,1,"MGNT:LI30:1:BTRMCTRL.FFVL")
#! Record("MGNT:LI30:1:BTRMSWITCH",460,322,0,0,"MGNT:LI30:1:BTRMSWITCH")
#! Field("MGNT:LI30:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:LI30:1:BTRMSWITCH.DOL1")
#! Link("MGNT:LI30:1:BTRMSWITCH.DOL1","MGNT:LI30:1:BTRMCTRL.FFVL")
#! Field("MGNT:LI30:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:LI30:1:BTRMSWITCH.LNK1")
#! Field("MGNT:LI30:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:LI30:1:BTRMSWITCH.FLNK")
#! Record("MGNT:LI30:1:ALLBTRMSGO",240,96,0,0,"MGNT:LI30:1:ALLBTRMSGO")
#! Field("MGNT:LI30:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:LI30:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:LI30:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:LI30:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:LI30:1:ALLBTRMSGO.LNK1","MGNT:LI30:1:ALLBTRMS.VAL")
#! Record("MGNT:LI30:1:ALLBTRMS",540,102,0,0,"MGNT:LI30:1:ALLBTRMS")
#! Field("MGNT:LI30:1:ALLBTRMS.VAL",16777215,0,"MGNT:LI30:1:ALLBTRMS.VAL")
#! Field("MGNT:LI30:1:ALLBTRMS.FLNK",16777215,1,"MGNT:LI30:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:LI30:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI30:1:LGPSSWITCH")
}

record(seq, "MGNT:LI30:1:LGPSSWITCH") {
  field(DOL1, "MGNT:LI30:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:LI30:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI30:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI30:1:LGPSCTRL")
}

record(seq, "MGNT:LI30:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:LI30:1:ALLSTAR")
  field(LNK1, "MGNT:LI30:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:LI30:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI30:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI30:1:LGPSCTRL",20,10,0,0,"MGNT:LI30:1:LGPSCTRL")
#! Field("MGNT:LI30:1:LGPSCTRL.FLNK",16777215,1,"MGNT:LI30:1:LGPSCTRL.FLNK")
#! Link("MGNT:LI30:1:LGPSCTRL.FLNK","MGNT:LI30:1:LGPSSWITCH")
#! Field("MGNT:LI30:1:LGPSCTRL.FFVL",16777215,1,"MGNT:LI30:1:LGPSCTRL.FFVL")
#! Record("MGNT:LI30:1:LGPSSWITCH",460,322,0,0,"MGNT:LI30:1:LGPSSWITCH")
#! Field("MGNT:LI30:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:LI30:1:LGPSSWITCH.DOL1")
#! Link("MGNT:LI30:1:LGPSSWITCH.DOL1","MGNT:LI30:1:LGPSCTRL.FFVL")
#! Field("MGNT:LI30:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:LI30:1:LGPSSWITCH.LNK1")
#! Field("MGNT:LI30:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:LI30:1:LGPSSWITCH.FLNK")
#! Record("MGNT:LI30:1:ALLLGPSSGO",240,96,0,0,"MGNT:LI30:1:ALLLGPSSGO")
#! Field("MGNT:LI30:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:LI30:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:LI30:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:LI30:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:LI30:1:ALLLGPSSGO.LNK1","MGNT:LI30:1:ALLLGPSS.VAL")
#! Record("MGNT:LI30:1:ALLLGPSS",540,102,0,0,"MGNT:LI30:1:ALLLGPSS")
#! Field("MGNT:LI30:1:ALLLGPSS.VAL",16777215,0,"MGNT:LI30:1:ALLLGPSS.VAL")
#! Field("MGNT:LI30:1:ALLLGPSS.FLNK",16777215,1,"MGNT:LI30:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:LI30:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:LI30:1:QUADSWITCH")
}

record(seq, "MGNT:LI30:1:QUADSWITCH") {
  field(DOL1, "MGNT:LI30:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:LI30:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI30:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI30:1:QUADCTRL")
}

record(seq, "MGNT:LI30:1:ALLQUADSGO") {
  field(DOL1, "MGNT:LI30:1:ALLSTAR")
  field(LNK1, "MGNT:LI30:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:LI30:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI30:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI30:1:QUADCTRL",20,10,0,0,"MGNT:LI30:1:QUADCTRL")
#! Field("MGNT:LI30:1:QUADCTRL.FLNK",16777215,1,"MGNT:LI30:1:QUADCTRL.FLNK")
#! Link("MGNT:LI30:1:QUADCTRL.FLNK","MGNT:LI30:1:QUADSWITCH")
#! Field("MGNT:LI30:1:QUADCTRL.FFVL",16777215,1,"MGNT:LI30:1:QUADCTRL.FFVL")
#! Record("MGNT:LI30:1:QUADSWITCH",460,322,0,0,"MGNT:LI30:1:QUADSWITCH")
#! Field("MGNT:LI30:1:QUADSWITCH.DOL1",16777215,0,"MGNT:LI30:1:QUADSWITCH.DOL1")
#! Link("MGNT:LI30:1:QUADSWITCH.DOL1","MGNT:LI30:1:QUADCTRL.FFVL")
#! Field("MGNT:LI30:1:QUADSWITCH.LNK1",16777215,1,"MGNT:LI30:1:QUADSWITCH.LNK1")
#! Field("MGNT:LI30:1:QUADSWITCH.FLNK",16777215,1,"MGNT:LI30:1:QUADSWITCH.FLNK")
#! Record("MGNT:LI30:1:ALLQUADSGO",240,96,0,0,"MGNT:LI30:1:ALLQUADSGO")
#! Field("MGNT:LI30:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:LI30:1:ALLQUADSGO.DOL1")
#! Field("MGNT:LI30:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:LI30:1:ALLQUADSGO.LNK1")
#! Link("MGNT:LI30:1:ALLQUADSGO.LNK1","MGNT:LI30:1:ALLQUADS.VAL")
#! Record("MGNT:LI30:1:ALLQUADS",540,102,0,0,"MGNT:LI30:1:ALLQUADS")
#! Field("MGNT:LI30:1:ALLQUADS.VAL",16777215,0,"MGNT:LI30:1:ALLQUADS.VAL")
#! Field("MGNT:LI30:1:ALLQUADS.FLNK",16777215,1,"MGNT:LI30:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:LI30:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:LI30:1:XCORSWITCH")
}

record(seq, "MGNT:LI30:1:XCORSWITCH") {
  field(DOL1, "MGNT:LI30:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:LI30:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI30:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI30:1:XCORCTRL")
}

record(seq, "MGNT:LI30:1:ALLXCORSGO") {
  field(DOL1, "MGNT:LI30:1:ALLSTAR")
  field(LNK1, "MGNT:LI30:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:LI30:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI30:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI30:1:XCORCTRL",20,10,0,0,"MGNT:LI30:1:XCORCTRL")
#! Field("MGNT:LI30:1:XCORCTRL.FLNK",16777215,1,"MGNT:LI30:1:XCORCTRL.FLNK")
#! Link("MGNT:LI30:1:XCORCTRL.FLNK","MGNT:LI30:1:XCORSWITCH")
#! Field("MGNT:LI30:1:XCORCTRL.FFVL",16777215,1,"MGNT:LI30:1:XCORCTRL.FFVL")
#! Record("MGNT:LI30:1:XCORSWITCH",460,322,0,0,"MGNT:LI30:1:XCORSWITCH")
#! Field("MGNT:LI30:1:XCORSWITCH.DOL1",16777215,0,"MGNT:LI30:1:XCORSWITCH.DOL1")
#! Link("MGNT:LI30:1:XCORSWITCH.DOL1","MGNT:LI30:1:XCORCTRL.FFVL")
#! Field("MGNT:LI30:1:XCORSWITCH.LNK1",16777215,1,"MGNT:LI30:1:XCORSWITCH.LNK1")
#! Field("MGNT:LI30:1:XCORSWITCH.FLNK",16777215,1,"MGNT:LI30:1:XCORSWITCH.FLNK")
#! Record("MGNT:LI30:1:ALLXCORSGO",240,96,0,0,"MGNT:LI30:1:ALLXCORSGO")
#! Field("MGNT:LI30:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:LI30:1:ALLXCORSGO.DOL1")
#! Field("MGNT:LI30:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:LI30:1:ALLXCORSGO.LNK1")
#! Link("MGNT:LI30:1:ALLXCORSGO.LNK1","MGNT:LI30:1:ALLXCORS.VAL")
#! Record("MGNT:LI30:1:ALLXCORS",540,102,0,0,"MGNT:LI30:1:ALLXCORS")
#! Field("MGNT:LI30:1:ALLXCORS.VAL",16777215,0,"MGNT:LI30:1:ALLXCORS.VAL")
#! Field("MGNT:LI30:1:ALLXCORS.FLNK",16777215,1,"MGNT:LI30:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:LI30:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:LI30:1:YCORSWITCH")
}

record(seq, "MGNT:LI30:1:YCORSWITCH") {
  field(DOL1, "MGNT:LI30:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:LI30:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI30:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI30:1:YCORCTRL")
}

record(seq, "MGNT:LI30:1:ALLYCORSGO") {
  field(DOL1, "MGNT:LI30:1:ALLSTAR")
  field(LNK1, "MGNT:LI30:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:LI30:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI30:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI30:1:YCORCTRL",20,10,0,0,"MGNT:LI30:1:YCORCTRL")
#! Field("MGNT:LI30:1:YCORCTRL.FLNK",16777215,1,"MGNT:LI30:1:YCORCTRL.FLNK")
#! Link("MGNT:LI30:1:YCORCTRL.FLNK","MGNT:LI30:1:YCORSWITCH")
#! Field("MGNT:LI30:1:YCORCTRL.FFVL",16777215,1,"MGNT:LI30:1:YCORCTRL.FFVL")
#! Record("MGNT:LI30:1:YCORSWITCH",460,322,0,0,"MGNT:LI30:1:YCORSWITCH")
#! Field("MGNT:LI30:1:YCORSWITCH.DOL1",16777215,0,"MGNT:LI30:1:YCORSWITCH.DOL1")
#! Link("MGNT:LI30:1:YCORSWITCH.DOL1","MGNT:LI30:1:YCORCTRL.FFVL")
#! Field("MGNT:LI30:1:YCORSWITCH.LNK1",16777215,1,"MGNT:LI30:1:YCORSWITCH.LNK1")
#! Field("MGNT:LI30:1:YCORSWITCH.FLNK",16777215,1,"MGNT:LI30:1:YCORSWITCH.FLNK")
#! Record("MGNT:LI30:1:ALLYCORSGO",240,96,0,0,"MGNT:LI30:1:ALLYCORSGO")
#! Field("MGNT:LI30:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:LI30:1:ALLYCORSGO.DOL1")
#! Field("MGNT:LI30:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:LI30:1:ALLYCORSGO.LNK1")
#! Link("MGNT:LI30:1:ALLYCORSGO.LNK1","MGNT:LI30:1:ALLYCORS.VAL")
#! Record("MGNT:LI30:1:ALLYCORS",540,102,0,0,"MGNT:LI30:1:ALLYCORS")
#! Field("MGNT:LI30:1:ALLYCORS.VAL",16777215,0,"MGNT:LI30:1:ALLYCORS.VAL")
#! Field("MGNT:LI30:1:ALLYCORS.FLNK",16777215,1,"MGNT:LI30:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:LI30:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:LI30:1:SOLNSWITCH")
}

record(seq, "MGNT:LI30:1:SOLNSWITCH") {
  field(DOL1, "MGNT:LI30:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:LI30:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI30:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI30:1:SOLNCTRL")
}

record(seq, "MGNT:LI30:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:LI30:1:ALLSTAR")
  field(LNK1, "MGNT:LI30:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:LI30:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI30:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI30:1:SOLNCTRL",20,10,0,0,"MGNT:LI30:1:SOLNCTRL")
#! Field("MGNT:LI30:1:SOLNCTRL.FLNK",16777215,1,"MGNT:LI30:1:SOLNCTRL.FLNK")
#! Link("MGNT:LI30:1:SOLNCTRL.FLNK","MGNT:LI30:1:SOLNSWITCH")
#! Field("MGNT:LI30:1:SOLNCTRL.FFVL",16777215,1,"MGNT:LI30:1:SOLNCTRL.FFVL")
#! Record("MGNT:LI30:1:SOLNSWITCH",460,322,0,0,"MGNT:LI30:1:SOLNSWITCH")
#! Field("MGNT:LI30:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:LI30:1:SOLNSWITCH.DOL1")
#! Link("MGNT:LI30:1:SOLNSWITCH.DOL1","MGNT:LI30:1:SOLNCTRL.FFVL")
#! Field("MGNT:LI30:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:LI30:1:SOLNSWITCH.LNK1")
#! Field("MGNT:LI30:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:LI30:1:SOLNSWITCH.FLNK")
#! Record("MGNT:LI30:1:ALLSOLNSGO",240,96,0,0,"MGNT:LI30:1:ALLSOLNSGO")
#! Field("MGNT:LI30:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:LI30:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:LI30:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:LI30:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:LI30:1:ALLSOLNSGO.LNK1","MGNT:LI30:1:ALLSOLNS.VAL")
#! Record("MGNT:LI30:1:ALLSOLNS",540,102,0,0,"MGNT:LI30:1:ALLSOLNS")
#! Field("MGNT:LI30:1:ALLSOLNS.VAL",16777215,0,"MGNT:LI30:1:ALLSOLNS.VAL")
#! Field("MGNT:LI30:1:ALLSOLNS.FLNK",16777215,1,"MGNT:LI30:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:LI30:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:LI30:1:KICKSWITCH")
}

record(seq, "MGNT:LI30:1:KICKSWITCH") {
  field(DOL1, "MGNT:LI30:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:LI30:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI30:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI30:1:KICKCTRL")
}

record(seq, "MGNT:LI30:1:ALLKICKSGO") {
  field(DOL1, "MGNT:LI30:1:ALLSTAR")
  field(LNK1, "MGNT:LI30:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:LI30:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI30:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI30:1:KICKCTRL",20,10,0,0,"MGNT:LI30:1:KICKCTRL")
#! Field("MGNT:LI30:1:KICKCTRL.FLNK",16777215,1,"MGNT:LI30:1:KICKCTRL.FLNK")
#! Link("MGNT:LI30:1:KICKCTRL.FLNK","MGNT:LI30:1:KICKSWITCH")
#! Field("MGNT:LI30:1:KICKCTRL.FFVL",16777215,1,"MGNT:LI30:1:KICKCTRL.FFVL")
#! Record("MGNT:LI30:1:KICKSWITCH",460,322,0,0,"MGNT:LI30:1:KICKSWITCH")
#! Field("MGNT:LI30:1:KICKSWITCH.DOL1",16777215,0,"MGNT:LI30:1:KICKSWITCH.DOL1")
#! Link("MGNT:LI30:1:KICKSWITCH.DOL1","MGNT:LI30:1:KICKCTRL.FFVL")
#! Field("MGNT:LI30:1:KICKSWITCH.LNK1",16777215,1,"MGNT:LI30:1:KICKSWITCH.LNK1")
#! Field("MGNT:LI30:1:KICKSWITCH.FLNK",16777215,1,"MGNT:LI30:1:KICKSWITCH.FLNK")
#! Record("MGNT:LI30:1:ALLKICKSGO",240,96,0,0,"MGNT:LI30:1:ALLKICKSGO")
#! Field("MGNT:LI30:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:LI30:1:ALLKICKSGO.DOL1")
#! Field("MGNT:LI30:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:LI30:1:ALLKICKSGO.LNK1")
#! Link("MGNT:LI30:1:ALLKICKSGO.LNK1","MGNT:LI30:1:ALLKICKS.VAL")
#! Record("MGNT:LI30:1:ALLKICKS",540,102,0,0,"MGNT:LI30:1:ALLKICKS")
#! Field("MGNT:LI30:1:ALLKICKS.VAL",16777215,0,"MGNT:LI30:1:ALLKICKS.VAL")
#! Field("MGNT:LI30:1:ALLKICKS.FLNK",16777215,1,"MGNT:LI30:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:LI30:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:LI30:1:SEXTSWITCH")
}

record(seq, "MGNT:LI30:1:SEXTSWITCH") {
  field(DOL1, "MGNT:LI30:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:LI30:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI30:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI30:1:SEXTCTRL")
}

record(seq, "MGNT:LI30:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:LI30:1:ALLSTAR")
  field(LNK1, "MGNT:LI30:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:LI30:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI30:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI30:1:SEXTCTRL",20,10,0,0,"MGNT:LI30:1:SEXTCTRL")
#! Field("MGNT:LI30:1:SEXTCTRL.FLNK",16777215,1,"MGNT:LI30:1:SEXTCTRL.FLNK")
#! Link("MGNT:LI30:1:SEXTCTRL.FLNK","MGNT:LI30:1:SEXTSWITCH")
#! Field("MGNT:LI30:1:SEXTCTRL.FFVL",16777215,1,"MGNT:LI30:1:SEXTCTRL.FFVL")
#! Record("MGNT:LI30:1:SEXTSWITCH",460,322,0,0,"MGNT:LI30:1:SEXTSWITCH")
#! Field("MGNT:LI30:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:LI30:1:SEXTSWITCH.DOL1")
#! Link("MGNT:LI30:1:SEXTSWITCH.DOL1","MGNT:LI30:1:SEXTCTRL.FFVL")
#! Field("MGNT:LI30:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:LI30:1:SEXTSWITCH.LNK1")
#! Field("MGNT:LI30:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:LI30:1:SEXTSWITCH.FLNK")
#! Record("MGNT:LI30:1:ALLSEXTSGO",240,96,0,0,"MGNT:LI30:1:ALLSEXTSGO")
#! Field("MGNT:LI30:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:LI30:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:LI30:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:LI30:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:LI30:1:ALLSEXTSGO.LNK1","MGNT:LI30:1:ALLSEXTS.VAL")
#! Record("MGNT:LI30:1:ALLSEXTS",540,102,0,0,"MGNT:LI30:1:ALLSEXTS")
#! Field("MGNT:LI30:1:ALLSEXTS.VAL",16777215,0,"MGNT:LI30:1:ALLSEXTS.VAL")
#! Field("MGNT:LI30:1:ALLSEXTS.FLNK",16777215,1,"MGNT:LI30:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:LI23:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:LI23:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:LI23:1:CTRL CA PP")
  field(LNK2, "MGNT:LI23:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:LI23:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:LI23:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:LI23:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:LI23:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:LI23:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:LI23:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:LI23:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:LI23:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:LI23:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:LI23:1:ALLSWITCH")
}

record(seq, "MGNT:LI23:1:ALLSWITCH") {
  field(DOL1, "MGNT:LI23:1:CTRL.FFVL")
  field(LNK1, "MGNT:LI23:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI23:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI23:1:CTRL")
}

record(bo, "MGNT:LI23:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:LI23:1:ALLSTARGO")
}

record(fanout, "MGNT:LI23:1:ALLSTARGO") {
  field(LNK1, "MGNT:LI23:1:ALLBENDSGO")
  field(LNK2, "MGNT:LI23:1:ALLBTRMSGO")
  field(LNK3, "MGNT:LI23:1:ALLLGPSSGO")
  field(LNK4, "MGNT:LI23:1:ALLQUADSGO")
  field(LNK5, "MGNT:LI23:1:ALLXCORSGO")
  field(LNK6, "MGNT:LI23:1:ALLYCORSGO")
  field(FLNK, "MGNT:LI23:1:ALLSTARGO_2")
}
record(fanout, "MGNT:LI23:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:LI23:1:ALLSOLNSGO")
  field(LNK2, "MGNT:LI23:1:ALLKICKSGO")
  field(LNK3, "MGNT:LI23:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:LI23:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:LI23:1:BENDSWITCH")
}

record(seq, "MGNT:LI23:1:BENDSWITCH") {
  field(DOL1, "MGNT:LI23:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:LI23:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI23:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI23:1:BENDCTRL")
}

record(seq, "MGNT:LI23:1:ALLBENDSGO") {
  field(DOL1, "MGNT:LI23:1:ALLSTAR")
  field(LNK1, "MGNT:LI23:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:LI23:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI23:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI23:1:BENDCTRL",20,10,0,0,"MGNT:LI23:1:BENDCTRL")
#! Field("MGNT:LI23:1:BENDCTRL.FLNK",16777215,1,"MGNT:LI23:1:BENDCTRL.FLNK")
#! Link("MGNT:LI23:1:BENDCTRL.FLNK","MGNT:LI23:1:BENDSWITCH")
#! Field("MGNT:LI23:1:BENDCTRL.FFVL",16777215,1,"MGNT:LI23:1:BENDCTRL.FFVL")
#! Record("MGNT:LI23:1:BENDSWITCH",460,322,0,0,"MGNT:LI23:1:BENDSWITCH")
#! Field("MGNT:LI23:1:BENDSWITCH.DOL1",16777215,0,"MGNT:LI23:1:BENDSWITCH.DOL1")
#! Link("MGNT:LI23:1:BENDSWITCH.DOL1","MGNT:LI23:1:BENDCTRL.FFVL")
#! Field("MGNT:LI23:1:BENDSWITCH.LNK1",16777215,1,"MGNT:LI23:1:BENDSWITCH.LNK1")
#! Field("MGNT:LI23:1:BENDSWITCH.FLNK",16777215,1,"MGNT:LI23:1:BENDSWITCH.FLNK")
#! Record("MGNT:LI23:1:ALLBENDSGO",240,96,0,0,"MGNT:LI23:1:ALLBENDSGO")
#! Field("MGNT:LI23:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:LI23:1:ALLBENDSGO.DOL1")
#! Field("MGNT:LI23:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:LI23:1:ALLBENDSGO.LNK1")
#! Link("MGNT:LI23:1:ALLBENDSGO.LNK1","MGNT:LI23:1:ALLBENDS.VAL")
#! Record("MGNT:LI23:1:ALLBENDS",540,102,0,0,"MGNT:LI23:1:ALLBENDS")
#! Field("MGNT:LI23:1:ALLBENDS.VAL",16777215,0,"MGNT:LI23:1:ALLBENDS.VAL")
#! Field("MGNT:LI23:1:ALLBENDS.FLNK",16777215,1,"MGNT:LI23:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:LI23:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI23:1:BTRMSWITCH")
}

record(seq, "MGNT:LI23:1:BTRMSWITCH") {
  field(DOL1, "MGNT:LI23:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:LI23:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI23:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI23:1:BTRMCTRL")
}

record(seq, "MGNT:LI23:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:LI23:1:ALLSTAR")
  field(LNK1, "MGNT:LI23:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:LI23:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI23:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI23:1:BTRMCTRL",20,10,0,0,"MGNT:LI23:1:BTRMCTRL")
#! Field("MGNT:LI23:1:BTRMCTRL.FLNK",16777215,1,"MGNT:LI23:1:BTRMCTRL.FLNK")
#! Link("MGNT:LI23:1:BTRMCTRL.FLNK","MGNT:LI23:1:BTRMSWITCH")
#! Field("MGNT:LI23:1:BTRMCTRL.FFVL",16777215,1,"MGNT:LI23:1:BTRMCTRL.FFVL")
#! Record("MGNT:LI23:1:BTRMSWITCH",460,322,0,0,"MGNT:LI23:1:BTRMSWITCH")
#! Field("MGNT:LI23:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:LI23:1:BTRMSWITCH.DOL1")
#! Link("MGNT:LI23:1:BTRMSWITCH.DOL1","MGNT:LI23:1:BTRMCTRL.FFVL")
#! Field("MGNT:LI23:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:LI23:1:BTRMSWITCH.LNK1")
#! Field("MGNT:LI23:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:LI23:1:BTRMSWITCH.FLNK")
#! Record("MGNT:LI23:1:ALLBTRMSGO",240,96,0,0,"MGNT:LI23:1:ALLBTRMSGO")
#! Field("MGNT:LI23:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:LI23:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:LI23:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:LI23:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:LI23:1:ALLBTRMSGO.LNK1","MGNT:LI23:1:ALLBTRMS.VAL")
#! Record("MGNT:LI23:1:ALLBTRMS",540,102,0,0,"MGNT:LI23:1:ALLBTRMS")
#! Field("MGNT:LI23:1:ALLBTRMS.VAL",16777215,0,"MGNT:LI23:1:ALLBTRMS.VAL")
#! Field("MGNT:LI23:1:ALLBTRMS.FLNK",16777215,1,"MGNT:LI23:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:LI23:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI23:1:LGPSSWITCH")
}

record(seq, "MGNT:LI23:1:LGPSSWITCH") {
  field(DOL1, "MGNT:LI23:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:LI23:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI23:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI23:1:LGPSCTRL")
}

record(seq, "MGNT:LI23:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:LI23:1:ALLSTAR")
  field(LNK1, "MGNT:LI23:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:LI23:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI23:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI23:1:LGPSCTRL",20,10,0,0,"MGNT:LI23:1:LGPSCTRL")
#! Field("MGNT:LI23:1:LGPSCTRL.FLNK",16777215,1,"MGNT:LI23:1:LGPSCTRL.FLNK")
#! Link("MGNT:LI23:1:LGPSCTRL.FLNK","MGNT:LI23:1:LGPSSWITCH")
#! Field("MGNT:LI23:1:LGPSCTRL.FFVL",16777215,1,"MGNT:LI23:1:LGPSCTRL.FFVL")
#! Record("MGNT:LI23:1:LGPSSWITCH",460,322,0,0,"MGNT:LI23:1:LGPSSWITCH")
#! Field("MGNT:LI23:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:LI23:1:LGPSSWITCH.DOL1")
#! Link("MGNT:LI23:1:LGPSSWITCH.DOL1","MGNT:LI23:1:LGPSCTRL.FFVL")
#! Field("MGNT:LI23:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:LI23:1:LGPSSWITCH.LNK1")
#! Field("MGNT:LI23:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:LI23:1:LGPSSWITCH.FLNK")
#! Record("MGNT:LI23:1:ALLLGPSSGO",240,96,0,0,"MGNT:LI23:1:ALLLGPSSGO")
#! Field("MGNT:LI23:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:LI23:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:LI23:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:LI23:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:LI23:1:ALLLGPSSGO.LNK1","MGNT:LI23:1:ALLLGPSS.VAL")
#! Record("MGNT:LI23:1:ALLLGPSS",540,102,0,0,"MGNT:LI23:1:ALLLGPSS")
#! Field("MGNT:LI23:1:ALLLGPSS.VAL",16777215,0,"MGNT:LI23:1:ALLLGPSS.VAL")
#! Field("MGNT:LI23:1:ALLLGPSS.FLNK",16777215,1,"MGNT:LI23:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:LI23:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:LI23:1:QUADSWITCH")
}

record(seq, "MGNT:LI23:1:QUADSWITCH") {
  field(DOL1, "MGNT:LI23:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:LI23:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI23:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI23:1:QUADCTRL")
}

record(seq, "MGNT:LI23:1:ALLQUADSGO") {
  field(DOL1, "MGNT:LI23:1:ALLSTAR")
  field(LNK1, "MGNT:LI23:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:LI23:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI23:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI23:1:QUADCTRL",20,10,0,0,"MGNT:LI23:1:QUADCTRL")
#! Field("MGNT:LI23:1:QUADCTRL.FLNK",16777215,1,"MGNT:LI23:1:QUADCTRL.FLNK")
#! Link("MGNT:LI23:1:QUADCTRL.FLNK","MGNT:LI23:1:QUADSWITCH")
#! Field("MGNT:LI23:1:QUADCTRL.FFVL",16777215,1,"MGNT:LI23:1:QUADCTRL.FFVL")
#! Record("MGNT:LI23:1:QUADSWITCH",460,322,0,0,"MGNT:LI23:1:QUADSWITCH")
#! Field("MGNT:LI23:1:QUADSWITCH.DOL1",16777215,0,"MGNT:LI23:1:QUADSWITCH.DOL1")
#! Link("MGNT:LI23:1:QUADSWITCH.DOL1","MGNT:LI23:1:QUADCTRL.FFVL")
#! Field("MGNT:LI23:1:QUADSWITCH.LNK1",16777215,1,"MGNT:LI23:1:QUADSWITCH.LNK1")
#! Field("MGNT:LI23:1:QUADSWITCH.FLNK",16777215,1,"MGNT:LI23:1:QUADSWITCH.FLNK")
#! Record("MGNT:LI23:1:ALLQUADSGO",240,96,0,0,"MGNT:LI23:1:ALLQUADSGO")
#! Field("MGNT:LI23:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:LI23:1:ALLQUADSGO.DOL1")
#! Field("MGNT:LI23:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:LI23:1:ALLQUADSGO.LNK1")
#! Link("MGNT:LI23:1:ALLQUADSGO.LNK1","MGNT:LI23:1:ALLQUADS.VAL")
#! Record("MGNT:LI23:1:ALLQUADS",540,102,0,0,"MGNT:LI23:1:ALLQUADS")
#! Field("MGNT:LI23:1:ALLQUADS.VAL",16777215,0,"MGNT:LI23:1:ALLQUADS.VAL")
#! Field("MGNT:LI23:1:ALLQUADS.FLNK",16777215,1,"MGNT:LI23:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:LI23:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:LI23:1:XCORSWITCH")
}

record(seq, "MGNT:LI23:1:XCORSWITCH") {
  field(DOL1, "MGNT:LI23:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:LI23:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI23:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI23:1:XCORCTRL")
}

record(seq, "MGNT:LI23:1:ALLXCORSGO") {
  field(DOL1, "MGNT:LI23:1:ALLSTAR")
  field(LNK1, "MGNT:LI23:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:LI23:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI23:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI23:1:XCORCTRL",20,10,0,0,"MGNT:LI23:1:XCORCTRL")
#! Field("MGNT:LI23:1:XCORCTRL.FLNK",16777215,1,"MGNT:LI23:1:XCORCTRL.FLNK")
#! Link("MGNT:LI23:1:XCORCTRL.FLNK","MGNT:LI23:1:XCORSWITCH")
#! Field("MGNT:LI23:1:XCORCTRL.FFVL",16777215,1,"MGNT:LI23:1:XCORCTRL.FFVL")
#! Record("MGNT:LI23:1:XCORSWITCH",460,322,0,0,"MGNT:LI23:1:XCORSWITCH")
#! Field("MGNT:LI23:1:XCORSWITCH.DOL1",16777215,0,"MGNT:LI23:1:XCORSWITCH.DOL1")
#! Link("MGNT:LI23:1:XCORSWITCH.DOL1","MGNT:LI23:1:XCORCTRL.FFVL")
#! Field("MGNT:LI23:1:XCORSWITCH.LNK1",16777215,1,"MGNT:LI23:1:XCORSWITCH.LNK1")
#! Field("MGNT:LI23:1:XCORSWITCH.FLNK",16777215,1,"MGNT:LI23:1:XCORSWITCH.FLNK")
#! Record("MGNT:LI23:1:ALLXCORSGO",240,96,0,0,"MGNT:LI23:1:ALLXCORSGO")
#! Field("MGNT:LI23:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:LI23:1:ALLXCORSGO.DOL1")
#! Field("MGNT:LI23:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:LI23:1:ALLXCORSGO.LNK1")
#! Link("MGNT:LI23:1:ALLXCORSGO.LNK1","MGNT:LI23:1:ALLXCORS.VAL")
#! Record("MGNT:LI23:1:ALLXCORS",540,102,0,0,"MGNT:LI23:1:ALLXCORS")
#! Field("MGNT:LI23:1:ALLXCORS.VAL",16777215,0,"MGNT:LI23:1:ALLXCORS.VAL")
#! Field("MGNT:LI23:1:ALLXCORS.FLNK",16777215,1,"MGNT:LI23:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:LI23:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:LI23:1:YCORSWITCH")
}

record(seq, "MGNT:LI23:1:YCORSWITCH") {
  field(DOL1, "MGNT:LI23:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:LI23:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI23:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI23:1:YCORCTRL")
}

record(seq, "MGNT:LI23:1:ALLYCORSGO") {
  field(DOL1, "MGNT:LI23:1:ALLSTAR")
  field(LNK1, "MGNT:LI23:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:LI23:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI23:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI23:1:YCORCTRL",20,10,0,0,"MGNT:LI23:1:YCORCTRL")
#! Field("MGNT:LI23:1:YCORCTRL.FLNK",16777215,1,"MGNT:LI23:1:YCORCTRL.FLNK")
#! Link("MGNT:LI23:1:YCORCTRL.FLNK","MGNT:LI23:1:YCORSWITCH")
#! Field("MGNT:LI23:1:YCORCTRL.FFVL",16777215,1,"MGNT:LI23:1:YCORCTRL.FFVL")
#! Record("MGNT:LI23:1:YCORSWITCH",460,322,0,0,"MGNT:LI23:1:YCORSWITCH")
#! Field("MGNT:LI23:1:YCORSWITCH.DOL1",16777215,0,"MGNT:LI23:1:YCORSWITCH.DOL1")
#! Link("MGNT:LI23:1:YCORSWITCH.DOL1","MGNT:LI23:1:YCORCTRL.FFVL")
#! Field("MGNT:LI23:1:YCORSWITCH.LNK1",16777215,1,"MGNT:LI23:1:YCORSWITCH.LNK1")
#! Field("MGNT:LI23:1:YCORSWITCH.FLNK",16777215,1,"MGNT:LI23:1:YCORSWITCH.FLNK")
#! Record("MGNT:LI23:1:ALLYCORSGO",240,96,0,0,"MGNT:LI23:1:ALLYCORSGO")
#! Field("MGNT:LI23:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:LI23:1:ALLYCORSGO.DOL1")
#! Field("MGNT:LI23:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:LI23:1:ALLYCORSGO.LNK1")
#! Link("MGNT:LI23:1:ALLYCORSGO.LNK1","MGNT:LI23:1:ALLYCORS.VAL")
#! Record("MGNT:LI23:1:ALLYCORS",540,102,0,0,"MGNT:LI23:1:ALLYCORS")
#! Field("MGNT:LI23:1:ALLYCORS.VAL",16777215,0,"MGNT:LI23:1:ALLYCORS.VAL")
#! Field("MGNT:LI23:1:ALLYCORS.FLNK",16777215,1,"MGNT:LI23:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:LI23:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:LI23:1:SOLNSWITCH")
}

record(seq, "MGNT:LI23:1:SOLNSWITCH") {
  field(DOL1, "MGNT:LI23:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:LI23:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI23:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI23:1:SOLNCTRL")
}

record(seq, "MGNT:LI23:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:LI23:1:ALLSTAR")
  field(LNK1, "MGNT:LI23:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:LI23:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI23:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI23:1:SOLNCTRL",20,10,0,0,"MGNT:LI23:1:SOLNCTRL")
#! Field("MGNT:LI23:1:SOLNCTRL.FLNK",16777215,1,"MGNT:LI23:1:SOLNCTRL.FLNK")
#! Link("MGNT:LI23:1:SOLNCTRL.FLNK","MGNT:LI23:1:SOLNSWITCH")
#! Field("MGNT:LI23:1:SOLNCTRL.FFVL",16777215,1,"MGNT:LI23:1:SOLNCTRL.FFVL")
#! Record("MGNT:LI23:1:SOLNSWITCH",460,322,0,0,"MGNT:LI23:1:SOLNSWITCH")
#! Field("MGNT:LI23:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:LI23:1:SOLNSWITCH.DOL1")
#! Link("MGNT:LI23:1:SOLNSWITCH.DOL1","MGNT:LI23:1:SOLNCTRL.FFVL")
#! Field("MGNT:LI23:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:LI23:1:SOLNSWITCH.LNK1")
#! Field("MGNT:LI23:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:LI23:1:SOLNSWITCH.FLNK")
#! Record("MGNT:LI23:1:ALLSOLNSGO",240,96,0,0,"MGNT:LI23:1:ALLSOLNSGO")
#! Field("MGNT:LI23:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:LI23:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:LI23:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:LI23:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:LI23:1:ALLSOLNSGO.LNK1","MGNT:LI23:1:ALLSOLNS.VAL")
#! Record("MGNT:LI23:1:ALLSOLNS",540,102,0,0,"MGNT:LI23:1:ALLSOLNS")
#! Field("MGNT:LI23:1:ALLSOLNS.VAL",16777215,0,"MGNT:LI23:1:ALLSOLNS.VAL")
#! Field("MGNT:LI23:1:ALLSOLNS.FLNK",16777215,1,"MGNT:LI23:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:LI23:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:LI23:1:KICKSWITCH")
}

record(seq, "MGNT:LI23:1:KICKSWITCH") {
  field(DOL1, "MGNT:LI23:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:LI23:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI23:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI23:1:KICKCTRL")
}

record(seq, "MGNT:LI23:1:ALLKICKSGO") {
  field(DOL1, "MGNT:LI23:1:ALLSTAR")
  field(LNK1, "MGNT:LI23:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:LI23:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI23:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI23:1:KICKCTRL",20,10,0,0,"MGNT:LI23:1:KICKCTRL")
#! Field("MGNT:LI23:1:KICKCTRL.FLNK",16777215,1,"MGNT:LI23:1:KICKCTRL.FLNK")
#! Link("MGNT:LI23:1:KICKCTRL.FLNK","MGNT:LI23:1:KICKSWITCH")
#! Field("MGNT:LI23:1:KICKCTRL.FFVL",16777215,1,"MGNT:LI23:1:KICKCTRL.FFVL")
#! Record("MGNT:LI23:1:KICKSWITCH",460,322,0,0,"MGNT:LI23:1:KICKSWITCH")
#! Field("MGNT:LI23:1:KICKSWITCH.DOL1",16777215,0,"MGNT:LI23:1:KICKSWITCH.DOL1")
#! Link("MGNT:LI23:1:KICKSWITCH.DOL1","MGNT:LI23:1:KICKCTRL.FFVL")
#! Field("MGNT:LI23:1:KICKSWITCH.LNK1",16777215,1,"MGNT:LI23:1:KICKSWITCH.LNK1")
#! Field("MGNT:LI23:1:KICKSWITCH.FLNK",16777215,1,"MGNT:LI23:1:KICKSWITCH.FLNK")
#! Record("MGNT:LI23:1:ALLKICKSGO",240,96,0,0,"MGNT:LI23:1:ALLKICKSGO")
#! Field("MGNT:LI23:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:LI23:1:ALLKICKSGO.DOL1")
#! Field("MGNT:LI23:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:LI23:1:ALLKICKSGO.LNK1")
#! Link("MGNT:LI23:1:ALLKICKSGO.LNK1","MGNT:LI23:1:ALLKICKS.VAL")
#! Record("MGNT:LI23:1:ALLKICKS",540,102,0,0,"MGNT:LI23:1:ALLKICKS")
#! Field("MGNT:LI23:1:ALLKICKS.VAL",16777215,0,"MGNT:LI23:1:ALLKICKS.VAL")
#! Field("MGNT:LI23:1:ALLKICKS.FLNK",16777215,1,"MGNT:LI23:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:LI23:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:LI23:1:SEXTSWITCH")
}

record(seq, "MGNT:LI23:1:SEXTSWITCH") {
  field(DOL1, "MGNT:LI23:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:LI23:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI23:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI23:1:SEXTCTRL")
}

record(seq, "MGNT:LI23:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:LI23:1:ALLSTAR")
  field(LNK1, "MGNT:LI23:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:LI23:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI23:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI23:1:SEXTCTRL",20,10,0,0,"MGNT:LI23:1:SEXTCTRL")
#! Field("MGNT:LI23:1:SEXTCTRL.FLNK",16777215,1,"MGNT:LI23:1:SEXTCTRL.FLNK")
#! Link("MGNT:LI23:1:SEXTCTRL.FLNK","MGNT:LI23:1:SEXTSWITCH")
#! Field("MGNT:LI23:1:SEXTCTRL.FFVL",16777215,1,"MGNT:LI23:1:SEXTCTRL.FFVL")
#! Record("MGNT:LI23:1:SEXTSWITCH",460,322,0,0,"MGNT:LI23:1:SEXTSWITCH")
#! Field("MGNT:LI23:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:LI23:1:SEXTSWITCH.DOL1")
#! Link("MGNT:LI23:1:SEXTSWITCH.DOL1","MGNT:LI23:1:SEXTCTRL.FFVL")
#! Field("MGNT:LI23:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:LI23:1:SEXTSWITCH.LNK1")
#! Field("MGNT:LI23:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:LI23:1:SEXTSWITCH.FLNK")
#! Record("MGNT:LI23:1:ALLSEXTSGO",240,96,0,0,"MGNT:LI23:1:ALLSEXTSGO")
#! Field("MGNT:LI23:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:LI23:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:LI23:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:LI23:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:LI23:1:ALLSEXTSGO.LNK1","MGNT:LI23:1:ALLSEXTS.VAL")
#! Record("MGNT:LI23:1:ALLSEXTS",540,102,0,0,"MGNT:LI23:1:ALLSEXTS")
#! Field("MGNT:LI23:1:ALLSEXTS.VAL",16777215,0,"MGNT:LI23:1:ALLSEXTS.VAL")
#! Field("MGNT:LI23:1:ALLSEXTS.FLNK",16777215,1,"MGNT:LI23:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record (seq, "MGNT:LI23:1:ALLBENDSSEL"){
}
record (seq, "MGNT:LI23:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:LI23:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:LI23:1:ALLKICKSSEL"){
}
record (seq, "MGNT:LI23:1:ALLSEXTSSEL"){
}

record (seq, "MGNT:LI23:1:ALLLGPSSSEL"){
  field (DOL1, "MGNT:LI23:1:ALLLGPSS")
  field (LNK1, "LGPS:LI23:2:SELECT CPP NMS")
}

record (seq, "MGNT:LI23:1:ALLQUADSSEL"){
  field (DOL1, "MGNT:LI23:1:ALLQUADS")
  field (DOL2, "MGNT:LI23:1:ALLQUADS")
  field (DOL3, "MGNT:LI23:1:ALLQUADS")
  field (DOL4, "MGNT:LI23:1:ALLQUADS")
  field (DOL5, "MGNT:LI23:1:ALLQUADS")
  field (DOL6, "MGNT:LI23:1:ALLQUADS")
  field (DOL7, "MGNT:LI23:1:ALLQUADS")
  field (DOL8, "MGNT:LI23:1:ALLQUADS")
  field (LNK1, "QUAD:LI23:201:SELECT CPP NMS")
  field (LNK2, "QUAD:LI23:301:SELECT CPP NMS")
  field (LNK3, "QUAD:LI23:401:SELECT CPP NMS")
  field (LNK4, "QUAD:LI23:501:SELECT CPP NMS")
  field (LNK5, "QUAD:LI23:601:SELECT CPP NMS")
  field (LNK6, "QUAD:LI23:701:SELECT CPP NMS")
  field (LNK7, "QUAD:LI23:801:SELECT CPP NMS")
  field (LNK8, "QUAD:LI23:901:SELECT CPP NMS")
}

record (seq, "MGNT:LI23:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:LI23:1:ALLXCORS")
  field (DOL2, "MGNT:LI23:1:ALLXCORS")
  field (DOL3, "MGNT:LI23:1:ALLXCORS")
  field (DOL4, "MGNT:LI23:1:ALLXCORS")
  field (DOL5, "MGNT:LI23:1:ALLXCORS")
  field (DOL6, "MGNT:LI23:1:ALLXCORS")
  field (DOL7, "MGNT:LI23:1:ALLXCORS")
  field (DOL8, "MGNT:LI23:1:ALLXCORS")
  field (LNK1, "XCOR:LI23:202:SELECT CPP NMS")
  field (LNK2, "XCOR:LI23:302:SELECT CPP NMS")
  field (LNK3, "XCOR:LI23:402:SELECT CPP NMS")
  field (LNK4, "XCOR:LI23:502:SELECT CPP NMS")
  field (LNK5, "XCOR:LI23:602:SELECT CPP NMS")
  field (LNK6, "XCOR:LI23:702:SELECT CPP NMS")
  field (LNK7, "XCOR:LI23:802:SELECT CPP NMS")
  field (LNK8, "XCOR:LI23:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI23:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:LI23:1:ALLYCORS")
  field (DOL2, "MGNT:LI23:1:ALLYCORS")
  field (DOL3, "MGNT:LI23:1:ALLYCORS")
  field (DOL4, "MGNT:LI23:1:ALLYCORS")
  field (DOL5, "MGNT:LI23:1:ALLYCORS")
  field (DOL6, "MGNT:LI23:1:ALLYCORS")
  field (DOL7, "MGNT:LI23:1:ALLYCORS")
  field (DOL8, "MGNT:LI23:1:ALLYCORS")
  field (LNK1, "YCOR:LI23:203:SELECT CPP NMS")
  field (LNK2, "YCOR:LI23:303:SELECT CPP NMS")
  field (LNK3, "YCOR:LI23:403:SELECT CPP NMS")
  field (LNK4, "YCOR:LI23:503:SELECT CPP NMS")
  field (LNK5, "YCOR:LI23:603:SELECT CPP NMS")
  field (LNK6, "YCOR:LI23:703:SELECT CPP NMS")
  field (LNK7, "YCOR:LI23:803:SELECT CPP NMS")
  field (LNK8, "YCOR:LI23:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI23:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (LNK1, "MGNT:LI23:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:LI23:1:QUADFUNCGO.PROC")
  field (LNK3, "MGNT:LI23:1:XCORFUNCGO.PROC")
  field (LNK4, "MGNT:LI23:1:YCORFUNCGO.PROC")
  field (LNK5, "MGNT:LI23:1:LGPSFUNCGO.PROC")
  field (LNK6, "MGNT:LI23:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:LI23:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI23:1:QUADFUNCGO") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI23:201:ALLFUNCGO")
  field (LNK2, "QUAD:LI23:301:ALLFUNCGO")
  field (LNK3, "QUAD:LI23:401:ALLFUNCGO")
  field (LNK4, "QUAD:LI23:501:ALLFUNCGO")
  field (LNK5, "QUAD:LI23:601:ALLFUNCGO")
  field (LNK6, "QUAD:LI23:701:ALLFUNCGO")
  field (FLNK, "MGNT:LI23:1:QUADFUNCGO1")
}

record (fanout, "MGNT:LI23:1:QUADFUNCGO1") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI23:801:ALLFUNCGO")
  field (LNK2, "QUAD:LI23:901:ALLFUNCGO")
  field (FLNK, "MGNT:LI23:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI23:1:XCORFUNCGO") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI23:202:ALLFUNCGO")
  field (LNK2, "XCOR:LI23:302:ALLFUNCGO")
  field (LNK3, "XCOR:LI23:402:ALLFUNCGO")
  field (LNK4, "XCOR:LI23:502:ALLFUNCGO")
  field (LNK5, "XCOR:LI23:602:ALLFUNCGO")
  field (LNK6, "XCOR:LI23:702:ALLFUNCGO")
  field (FLNK, "MGNT:LI23:1:XCORFUNCGO1")
}

record (fanout, "MGNT:LI23:1:XCORFUNCGO1") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI23:802:ALLFUNCGO")
  field (LNK2, "XCOR:LI23:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI23:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI23:1:YCORFUNCGO") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI23:203:ALLFUNCGO")
  field (LNK2, "YCOR:LI23:303:ALLFUNCGO")
  field (LNK3, "YCOR:LI23:403:ALLFUNCGO")
  field (LNK4, "YCOR:LI23:503:ALLFUNCGO")
  field (LNK5, "YCOR:LI23:603:ALLFUNCGO")
  field (LNK6, "YCOR:LI23:703:ALLFUNCGO")
  field (FLNK, "MGNT:LI23:1:YCORFUNCGO1")
}

record (fanout, "MGNT:LI23:1:YCORFUNCGO1") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI23:803:ALLFUNCGO")
  field (LNK2, "YCOR:LI23:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI23:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI23:1:LGPSFUNCGO"){
  field (DESC, "Process LGPS CTRL func")
  field (LNK1, "LGPS:LI23:2:ALLFUNCGO")
  field (FLNK, "MGNT:LI23:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI23:1:BENDFUNCGO"){
  field (DESC, "Process BEND CTRL func")
  field (FLNK, "MGNT:LI23:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI23:1:BTRMFUNCGO"){
  field (DESC, "Process BTRM CTRL func")
  field (FLNK, "MGNT:LI23:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI23:1:SOLNFUNCGO"){
  field (DESC, "Process SOLN CTRL func")
  field (FLNK, "MGNT:LI23:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI23:1:KICKFUNCGO"){
  field (DESC, "Process KICK CTRL func")
  field (FLNK, "MGNT:LI23:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI23:1:SEXTFUNCGO"){
  field (DESC, "Process SEXT CTRL func")
  field (FLNK, "MGNT:LI23:1:CTRLCLEAR")
}




#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LI23:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "LGPS:LI23:2:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LI23:2:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LI23:2:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LI23:2:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LI23:2:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LI23:2:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LI23:2:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LI23:2:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LI23:2:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LI23:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LI23:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LI23:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LI23:2:EDES.PROC PP")
    field(LNK2, "LGPS:LI23:2:EACT.PROC PP")
    field(LNK3, "LGPS:LI23:2:EERR.DISA PP")
    field(LNK4, "LGPS:LI23:2:ECON.PROC PP")
    field(LNK5, "LGPS:LI23:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:LI23:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:LI23:2:BLEM.PROC PP")
    field(LNK8, "LGPS:LI23:2:BMOD.PROC PP")
    field(LNK9, "LGPS:LI23:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LI23:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LI23:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LI23:2:BMAX")
  field(DOL2, "LGPS:LI23:2:BMAX")
  field(DOL3, "LGPS:LI23:2:BMAX")
  field(DOL4, "LGPS:LI23:2:BMIN")
  field(DOL5, "LGPS:LI23:2:BMIN")
  field(DOL6, "LGPS:LI23:2:BMIN")
  field(LNK1, "LGPS:LI23:2:BMAGX.HOPR")
  field(LNK2, "LGPS:LI23:2:BMAGY.HOPR")
  field(LNK3, "LGPS:LI23:2:BLEM.HOPR")
  field(LNK4, "LGPS:LI23:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LI23:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LI23:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LI23:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LI23:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LI23:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LI23:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LI23:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI23:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI23:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI23:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI23:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI23:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LI23:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LI23:2:EDES NPP MS")
  field(INPB, "LGPS:LI23:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI23:201:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI23:201:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI23:201:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI23:201:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI23:201:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI23:201:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI23:201:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI23:201:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI23:201:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI23:201:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI23:201:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI23:201:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI23:201:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI23:201:EDES.PROC PP")
    field(LNK2, "QUAD:LI23:201:EACT.PROC PP")
    field(LNK3, "QUAD:LI23:201:EERR.DISA PP")
    field(LNK4, "QUAD:LI23:201:ECON.PROC PP")
    field(LNK5, "QUAD:LI23:201:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI23:201:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI23:201:BLEM.PROC PP")
    field(LNK8, "QUAD:LI23:201:BMOD.PROC PP")
    field(LNK9, "QUAD:LI23:201:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI23:201:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI23:201:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI23:201:BMAX")
  field(DOL2, "QUAD:LI23:201:BMAX")
  field(DOL3, "QUAD:LI23:201:BMAX")
  field(DOL4, "QUAD:LI23:201:BMIN")
  field(DOL5, "QUAD:LI23:201:BMIN")
  field(DOL6, "QUAD:LI23:201:BMIN")
  field(LNK1, "QUAD:LI23:201:BMAGX.HOPR")
  field(LNK2, "QUAD:LI23:201:BMAGY.HOPR")
  field(LNK3, "QUAD:LI23:201:BLEM.HOPR")
  field(LNK4, "QUAD:LI23:201:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI23:201:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI23:201:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:201:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:201:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI23:201:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI23:201:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI23:201:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:201:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:201:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:201:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:201:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:201:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI23:201:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI23:201:EDES NPP MS")
  field(INPB, "QUAD:LI23:201:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI23:301:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI23:301:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI23:301:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI23:301:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI23:301:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI23:301:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI23:301:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI23:301:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI23:301:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI23:301:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI23:301:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI23:301:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI23:301:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI23:301:EDES.PROC PP")
    field(LNK2, "QUAD:LI23:301:EACT.PROC PP")
    field(LNK3, "QUAD:LI23:301:EERR.DISA PP")
    field(LNK4, "QUAD:LI23:301:ECON.PROC PP")
    field(LNK5, "QUAD:LI23:301:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI23:301:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI23:301:BLEM.PROC PP")
    field(LNK8, "QUAD:LI23:301:BMOD.PROC PP")
    field(LNK9, "QUAD:LI23:301:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI23:301:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI23:301:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI23:301:BMAX")
  field(DOL2, "QUAD:LI23:301:BMAX")
  field(DOL3, "QUAD:LI23:301:BMAX")
  field(DOL4, "QUAD:LI23:301:BMIN")
  field(DOL5, "QUAD:LI23:301:BMIN")
  field(DOL6, "QUAD:LI23:301:BMIN")
  field(LNK1, "QUAD:LI23:301:BMAGX.HOPR")
  field(LNK2, "QUAD:LI23:301:BMAGY.HOPR")
  field(LNK3, "QUAD:LI23:301:BLEM.HOPR")
  field(LNK4, "QUAD:LI23:301:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI23:301:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI23:301:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:301:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:301:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI23:301:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI23:301:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI23:301:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:301:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:301:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:301:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:301:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:301:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI23:301:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI23:301:EDES NPP MS")
  field(INPB, "QUAD:LI23:301:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI23:401:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI23:401:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI23:401:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI23:401:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI23:401:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI23:401:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI23:401:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI23:401:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI23:401:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI23:401:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI23:401:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI23:401:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI23:401:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI23:401:EDES.PROC PP")
    field(LNK2, "QUAD:LI23:401:EACT.PROC PP")
    field(LNK3, "QUAD:LI23:401:EERR.DISA PP")
    field(LNK4, "QUAD:LI23:401:ECON.PROC PP")
    field(LNK5, "QUAD:LI23:401:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI23:401:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI23:401:BLEM.PROC PP")
    field(LNK8, "QUAD:LI23:401:BMOD.PROC PP")
    field(LNK9, "QUAD:LI23:401:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI23:401:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI23:401:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI23:401:BMAX")
  field(DOL2, "QUAD:LI23:401:BMAX")
  field(DOL3, "QUAD:LI23:401:BMAX")
  field(DOL4, "QUAD:LI23:401:BMIN")
  field(DOL5, "QUAD:LI23:401:BMIN")
  field(DOL6, "QUAD:LI23:401:BMIN")
  field(LNK1, "QUAD:LI23:401:BMAGX.HOPR")
  field(LNK2, "QUAD:LI23:401:BMAGY.HOPR")
  field(LNK3, "QUAD:LI23:401:BLEM.HOPR")
  field(LNK4, "QUAD:LI23:401:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI23:401:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI23:401:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:401:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:401:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI23:401:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI23:401:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI23:401:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:401:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:401:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:401:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:401:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:401:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI23:401:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI23:401:EDES NPP MS")
  field(INPB, "QUAD:LI23:401:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI23:501:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI23:501:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI23:501:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI23:501:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI23:501:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI23:501:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI23:501:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI23:501:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI23:501:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI23:501:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI23:501:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI23:501:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI23:501:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI23:501:EDES.PROC PP")
    field(LNK2, "QUAD:LI23:501:EACT.PROC PP")
    field(LNK3, "QUAD:LI23:501:EERR.DISA PP")
    field(LNK4, "QUAD:LI23:501:ECON.PROC PP")
    field(LNK5, "QUAD:LI23:501:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI23:501:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI23:501:BLEM.PROC PP")
    field(LNK8, "QUAD:LI23:501:BMOD.PROC PP")
    field(LNK9, "QUAD:LI23:501:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI23:501:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI23:501:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI23:501:BMAX")
  field(DOL2, "QUAD:LI23:501:BMAX")
  field(DOL3, "QUAD:LI23:501:BMAX")
  field(DOL4, "QUAD:LI23:501:BMIN")
  field(DOL5, "QUAD:LI23:501:BMIN")
  field(DOL6, "QUAD:LI23:501:BMIN")
  field(LNK1, "QUAD:LI23:501:BMAGX.HOPR")
  field(LNK2, "QUAD:LI23:501:BMAGY.HOPR")
  field(LNK3, "QUAD:LI23:501:BLEM.HOPR")
  field(LNK4, "QUAD:LI23:501:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI23:501:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI23:501:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:501:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:501:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI23:501:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI23:501:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI23:501:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:501:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:501:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:501:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:501:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:501:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI23:501:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI23:501:EDES NPP MS")
  field(INPB, "QUAD:LI23:501:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI23:601:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI23:601:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI23:601:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI23:601:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI23:601:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI23:601:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI23:601:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI23:601:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI23:601:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI23:601:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI23:601:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI23:601:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI23:601:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI23:601:EDES.PROC PP")
    field(LNK2, "QUAD:LI23:601:EACT.PROC PP")
    field(LNK3, "QUAD:LI23:601:EERR.DISA PP")
    field(LNK4, "QUAD:LI23:601:ECON.PROC PP")
    field(LNK5, "QUAD:LI23:601:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI23:601:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI23:601:BLEM.PROC PP")
    field(LNK8, "QUAD:LI23:601:BMOD.PROC PP")
    field(LNK9, "QUAD:LI23:601:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI23:601:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI23:601:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI23:601:BMAX")
  field(DOL2, "QUAD:LI23:601:BMAX")
  field(DOL3, "QUAD:LI23:601:BMAX")
  field(DOL4, "QUAD:LI23:601:BMIN")
  field(DOL5, "QUAD:LI23:601:BMIN")
  field(DOL6, "QUAD:LI23:601:BMIN")
  field(LNK1, "QUAD:LI23:601:BMAGX.HOPR")
  field(LNK2, "QUAD:LI23:601:BMAGY.HOPR")
  field(LNK3, "QUAD:LI23:601:BLEM.HOPR")
  field(LNK4, "QUAD:LI23:601:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI23:601:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI23:601:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:601:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:601:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI23:601:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI23:601:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI23:601:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:601:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:601:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:601:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:601:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:601:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI23:601:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI23:601:EDES NPP MS")
  field(INPB, "QUAD:LI23:601:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI23:701:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI23:701:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI23:701:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI23:701:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI23:701:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI23:701:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI23:701:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI23:701:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI23:701:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI23:701:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI23:701:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI23:701:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI23:701:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI23:701:EDES.PROC PP")
    field(LNK2, "QUAD:LI23:701:EACT.PROC PP")
    field(LNK3, "QUAD:LI23:701:EERR.DISA PP")
    field(LNK4, "QUAD:LI23:701:ECON.PROC PP")
    field(LNK5, "QUAD:LI23:701:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI23:701:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI23:701:BLEM.PROC PP")
    field(LNK8, "QUAD:LI23:701:BMOD.PROC PP")
    field(LNK9, "QUAD:LI23:701:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI23:701:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI23:701:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI23:701:BMAX")
  field(DOL2, "QUAD:LI23:701:BMAX")
  field(DOL3, "QUAD:LI23:701:BMAX")
  field(DOL4, "QUAD:LI23:701:BMIN")
  field(DOL5, "QUAD:LI23:701:BMIN")
  field(DOL6, "QUAD:LI23:701:BMIN")
  field(LNK1, "QUAD:LI23:701:BMAGX.HOPR")
  field(LNK2, "QUAD:LI23:701:BMAGY.HOPR")
  field(LNK3, "QUAD:LI23:701:BLEM.HOPR")
  field(LNK4, "QUAD:LI23:701:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI23:701:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI23:701:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:701:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:701:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI23:701:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI23:701:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI23:701:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:701:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:701:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:701:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:701:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:701:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI23:701:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI23:701:EDES NPP MS")
  field(INPB, "QUAD:LI23:701:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI23:801:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI23:801:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI23:801:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI23:801:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI23:801:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI23:801:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI23:801:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI23:801:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI23:801:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI23:801:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI23:801:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI23:801:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI23:801:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI23:801:EDES.PROC PP")
    field(LNK2, "QUAD:LI23:801:EACT.PROC PP")
    field(LNK3, "QUAD:LI23:801:EERR.DISA PP")
    field(LNK4, "QUAD:LI23:801:ECON.PROC PP")
    field(LNK5, "QUAD:LI23:801:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI23:801:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI23:801:BLEM.PROC PP")
    field(LNK8, "QUAD:LI23:801:BMOD.PROC PP")
    field(LNK9, "QUAD:LI23:801:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI23:801:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI23:801:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI23:801:BMAX")
  field(DOL2, "QUAD:LI23:801:BMAX")
  field(DOL3, "QUAD:LI23:801:BMAX")
  field(DOL4, "QUAD:LI23:801:BMIN")
  field(DOL5, "QUAD:LI23:801:BMIN")
  field(DOL6, "QUAD:LI23:801:BMIN")
  field(LNK1, "QUAD:LI23:801:BMAGX.HOPR")
  field(LNK2, "QUAD:LI23:801:BMAGY.HOPR")
  field(LNK3, "QUAD:LI23:801:BLEM.HOPR")
  field(LNK4, "QUAD:LI23:801:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI23:801:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI23:801:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:801:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:801:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI23:801:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI23:801:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI23:801:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:801:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:801:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:801:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:801:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:801:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI23:801:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI23:801:EDES NPP MS")
  field(INPB, "QUAD:LI23:801:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI23:901:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI23:901:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI23:901:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI23:901:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI23:901:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI23:901:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI23:901:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI23:901:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI23:901:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI23:901:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI23:901:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI23:901:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI23:901:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI23:901:EDES.PROC PP")
    field(LNK2, "QUAD:LI23:901:EACT.PROC PP")
    field(LNK3, "QUAD:LI23:901:EERR.DISA PP")
    field(LNK4, "QUAD:LI23:901:ECON.PROC PP")
    field(LNK5, "QUAD:LI23:901:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI23:901:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI23:901:BLEM.PROC PP")
    field(LNK8, "QUAD:LI23:901:BMOD.PROC PP")
    field(LNK9, "QUAD:LI23:901:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI23:901:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI23:901:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI23:901:BMAX")
  field(DOL2, "QUAD:LI23:901:BMAX")
  field(DOL3, "QUAD:LI23:901:BMAX")
  field(DOL4, "QUAD:LI23:901:BMIN")
  field(DOL5, "QUAD:LI23:901:BMIN")
  field(DOL6, "QUAD:LI23:901:BMIN")
  field(LNK1, "QUAD:LI23:901:BMAGX.HOPR")
  field(LNK2, "QUAD:LI23:901:BMAGY.HOPR")
  field(LNK3, "QUAD:LI23:901:BLEM.HOPR")
  field(LNK4, "QUAD:LI23:901:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI23:901:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI23:901:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:901:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI23:901:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI23:901:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI23:901:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI23:901:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:901:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:901:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:901:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI23:901:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI23:901:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI23:901:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI23:901:EDES NPP MS")
  field(INPB, "QUAD:LI23:901:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI23:202:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI23:202:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI23:202:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI23:202:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI23:202:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI23:202:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI23:202:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI23:202:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI23:202:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI23:202:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI23:202:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI23:202:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI23:202:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI23:202:EDES.PROC PP")
    field(LNK2, "XCOR:LI23:202:EACT.PROC PP")
    field(LNK3, "XCOR:LI23:202:EERR.DISA PP")
    field(LNK4, "XCOR:LI23:202:ECON.PROC PP")
    field(LNK5, "XCOR:LI23:202:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI23:202:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI23:202:BLEM.PROC PP")
    field(LNK8, "XCOR:LI23:202:BMOD.PROC PP")
    field(LNK9, "XCOR:LI23:202:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI23:202:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI23:202:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI23:202:BMAX")
  field(DOL2, "XCOR:LI23:202:BMAX")
  field(DOL3, "XCOR:LI23:202:BMAX")
  field(DOL4, "XCOR:LI23:202:BMIN")
  field(DOL5, "XCOR:LI23:202:BMIN")
  field(DOL6, "XCOR:LI23:202:BMIN")
  field(LNK1, "XCOR:LI23:202:BMAGX.HOPR")
  field(LNK2, "XCOR:LI23:202:BMAGY.HOPR")
  field(LNK3, "XCOR:LI23:202:BLEM.HOPR")
  field(LNK4, "XCOR:LI23:202:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI23:202:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI23:202:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:202:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:202:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI23:202:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI23:202:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI23:202:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:202:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:202:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:202:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:202:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:202:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI23:202:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI23:202:EDES NPP MS")
  field(INPB, "XCOR:LI23:202:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI23:302:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI23:302:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI23:302:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI23:302:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI23:302:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI23:302:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI23:302:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI23:302:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI23:302:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI23:302:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI23:302:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI23:302:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI23:302:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI23:302:EDES.PROC PP")
    field(LNK2, "XCOR:LI23:302:EACT.PROC PP")
    field(LNK3, "XCOR:LI23:302:EERR.DISA PP")
    field(LNK4, "XCOR:LI23:302:ECON.PROC PP")
    field(LNK5, "XCOR:LI23:302:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI23:302:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI23:302:BLEM.PROC PP")
    field(LNK8, "XCOR:LI23:302:BMOD.PROC PP")
    field(LNK9, "XCOR:LI23:302:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI23:302:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI23:302:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI23:302:BMAX")
  field(DOL2, "XCOR:LI23:302:BMAX")
  field(DOL3, "XCOR:LI23:302:BMAX")
  field(DOL4, "XCOR:LI23:302:BMIN")
  field(DOL5, "XCOR:LI23:302:BMIN")
  field(DOL6, "XCOR:LI23:302:BMIN")
  field(LNK1, "XCOR:LI23:302:BMAGX.HOPR")
  field(LNK2, "XCOR:LI23:302:BMAGY.HOPR")
  field(LNK3, "XCOR:LI23:302:BLEM.HOPR")
  field(LNK4, "XCOR:LI23:302:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI23:302:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI23:302:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:302:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:302:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI23:302:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI23:302:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI23:302:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:302:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:302:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:302:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:302:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:302:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI23:302:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI23:302:EDES NPP MS")
  field(INPB, "XCOR:LI23:302:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI23:402:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI23:402:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI23:402:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI23:402:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI23:402:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI23:402:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI23:402:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI23:402:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI23:402:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI23:402:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI23:402:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI23:402:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI23:402:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI23:402:EDES.PROC PP")
    field(LNK2, "XCOR:LI23:402:EACT.PROC PP")
    field(LNK3, "XCOR:LI23:402:EERR.DISA PP")
    field(LNK4, "XCOR:LI23:402:ECON.PROC PP")
    field(LNK5, "XCOR:LI23:402:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI23:402:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI23:402:BLEM.PROC PP")
    field(LNK8, "XCOR:LI23:402:BMOD.PROC PP")
    field(LNK9, "XCOR:LI23:402:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI23:402:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI23:402:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI23:402:BMAX")
  field(DOL2, "XCOR:LI23:402:BMAX")
  field(DOL3, "XCOR:LI23:402:BMAX")
  field(DOL4, "XCOR:LI23:402:BMIN")
  field(DOL5, "XCOR:LI23:402:BMIN")
  field(DOL6, "XCOR:LI23:402:BMIN")
  field(LNK1, "XCOR:LI23:402:BMAGX.HOPR")
  field(LNK2, "XCOR:LI23:402:BMAGY.HOPR")
  field(LNK3, "XCOR:LI23:402:BLEM.HOPR")
  field(LNK4, "XCOR:LI23:402:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI23:402:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI23:402:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:402:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:402:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI23:402:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI23:402:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI23:402:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:402:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:402:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:402:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:402:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:402:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI23:402:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI23:402:EDES NPP MS")
  field(INPB, "XCOR:LI23:402:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI23:502:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI23:502:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI23:502:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI23:502:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI23:502:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI23:502:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI23:502:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI23:502:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI23:502:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI23:502:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI23:502:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI23:502:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI23:502:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI23:502:EDES.PROC PP")
    field(LNK2, "XCOR:LI23:502:EACT.PROC PP")
    field(LNK3, "XCOR:LI23:502:EERR.DISA PP")
    field(LNK4, "XCOR:LI23:502:ECON.PROC PP")
    field(LNK5, "XCOR:LI23:502:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI23:502:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI23:502:BLEM.PROC PP")
    field(LNK8, "XCOR:LI23:502:BMOD.PROC PP")
    field(LNK9, "XCOR:LI23:502:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI23:502:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI23:502:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI23:502:BMAX")
  field(DOL2, "XCOR:LI23:502:BMAX")
  field(DOL3, "XCOR:LI23:502:BMAX")
  field(DOL4, "XCOR:LI23:502:BMIN")
  field(DOL5, "XCOR:LI23:502:BMIN")
  field(DOL6, "XCOR:LI23:502:BMIN")
  field(LNK1, "XCOR:LI23:502:BMAGX.HOPR")
  field(LNK2, "XCOR:LI23:502:BMAGY.HOPR")
  field(LNK3, "XCOR:LI23:502:BLEM.HOPR")
  field(LNK4, "XCOR:LI23:502:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI23:502:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI23:502:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:502:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:502:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI23:502:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI23:502:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI23:502:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:502:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:502:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:502:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:502:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:502:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI23:502:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI23:502:EDES NPP MS")
  field(INPB, "XCOR:LI23:502:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI23:602:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI23:602:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI23:602:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI23:602:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI23:602:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI23:602:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI23:602:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI23:602:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI23:602:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI23:602:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI23:602:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI23:602:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI23:602:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI23:602:EDES.PROC PP")
    field(LNK2, "XCOR:LI23:602:EACT.PROC PP")
    field(LNK3, "XCOR:LI23:602:EERR.DISA PP")
    field(LNK4, "XCOR:LI23:602:ECON.PROC PP")
    field(LNK5, "XCOR:LI23:602:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI23:602:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI23:602:BLEM.PROC PP")
    field(LNK8, "XCOR:LI23:602:BMOD.PROC PP")
    field(LNK9, "XCOR:LI23:602:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI23:602:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI23:602:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI23:602:BMAX")
  field(DOL2, "XCOR:LI23:602:BMAX")
  field(DOL3, "XCOR:LI23:602:BMAX")
  field(DOL4, "XCOR:LI23:602:BMIN")
  field(DOL5, "XCOR:LI23:602:BMIN")
  field(DOL6, "XCOR:LI23:602:BMIN")
  field(LNK1, "XCOR:LI23:602:BMAGX.HOPR")
  field(LNK2, "XCOR:LI23:602:BMAGY.HOPR")
  field(LNK3, "XCOR:LI23:602:BLEM.HOPR")
  field(LNK4, "XCOR:LI23:602:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI23:602:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI23:602:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:602:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:602:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI23:602:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI23:602:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI23:602:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:602:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:602:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:602:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:602:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:602:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI23:602:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI23:602:EDES NPP MS")
  field(INPB, "XCOR:LI23:602:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI23:702:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI23:702:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI23:702:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI23:702:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI23:702:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI23:702:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI23:702:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI23:702:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI23:702:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI23:702:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI23:702:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI23:702:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI23:702:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI23:702:EDES.PROC PP")
    field(LNK2, "XCOR:LI23:702:EACT.PROC PP")
    field(LNK3, "XCOR:LI23:702:EERR.DISA PP")
    field(LNK4, "XCOR:LI23:702:ECON.PROC PP")
    field(LNK5, "XCOR:LI23:702:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI23:702:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI23:702:BLEM.PROC PP")
    field(LNK8, "XCOR:LI23:702:BMOD.PROC PP")
    field(LNK9, "XCOR:LI23:702:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI23:702:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI23:702:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI23:702:BMAX")
  field(DOL2, "XCOR:LI23:702:BMAX")
  field(DOL3, "XCOR:LI23:702:BMAX")
  field(DOL4, "XCOR:LI23:702:BMIN")
  field(DOL5, "XCOR:LI23:702:BMIN")
  field(DOL6, "XCOR:LI23:702:BMIN")
  field(LNK1, "XCOR:LI23:702:BMAGX.HOPR")
  field(LNK2, "XCOR:LI23:702:BMAGY.HOPR")
  field(LNK3, "XCOR:LI23:702:BLEM.HOPR")
  field(LNK4, "XCOR:LI23:702:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI23:702:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI23:702:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:702:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:702:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI23:702:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI23:702:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI23:702:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:702:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:702:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:702:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:702:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:702:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI23:702:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI23:702:EDES NPP MS")
  field(INPB, "XCOR:LI23:702:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI23:802:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI23:802:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI23:802:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI23:802:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI23:802:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI23:802:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI23:802:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI23:802:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI23:802:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI23:802:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI23:802:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI23:802:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI23:802:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI23:802:EDES.PROC PP")
    field(LNK2, "XCOR:LI23:802:EACT.PROC PP")
    field(LNK3, "XCOR:LI23:802:EERR.DISA PP")
    field(LNK4, "XCOR:LI23:802:ECON.PROC PP")
    field(LNK5, "XCOR:LI23:802:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI23:802:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI23:802:BLEM.PROC PP")
    field(LNK8, "XCOR:LI23:802:BMOD.PROC PP")
    field(LNK9, "XCOR:LI23:802:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI23:802:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI23:802:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI23:802:BMAX")
  field(DOL2, "XCOR:LI23:802:BMAX")
  field(DOL3, "XCOR:LI23:802:BMAX")
  field(DOL4, "XCOR:LI23:802:BMIN")
  field(DOL5, "XCOR:LI23:802:BMIN")
  field(DOL6, "XCOR:LI23:802:BMIN")
  field(LNK1, "XCOR:LI23:802:BMAGX.HOPR")
  field(LNK2, "XCOR:LI23:802:BMAGY.HOPR")
  field(LNK3, "XCOR:LI23:802:BLEM.HOPR")
  field(LNK4, "XCOR:LI23:802:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI23:802:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI23:802:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:802:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:802:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI23:802:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI23:802:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI23:802:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:802:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:802:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:802:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:802:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:802:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI23:802:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI23:802:EDES NPP MS")
  field(INPB, "XCOR:LI23:802:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI23:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI23:900:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI23:900:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI23:900:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI23:900:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI23:900:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI23:900:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI23:900:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI23:900:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI23:900:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI23:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI23:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI23:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI23:900:EDES.PROC PP")
    field(LNK2, "XCOR:LI23:900:EACT.PROC PP")
    field(LNK3, "XCOR:LI23:900:EERR.DISA PP")
    field(LNK4, "XCOR:LI23:900:ECON.PROC PP")
    field(LNK5, "XCOR:LI23:900:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI23:900:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI23:900:BLEM.PROC PP")
    field(LNK8, "XCOR:LI23:900:BMOD.PROC PP")
    field(LNK9, "XCOR:LI23:900:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI23:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI23:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI23:900:BMAX")
  field(DOL2, "XCOR:LI23:900:BMAX")
  field(DOL3, "XCOR:LI23:900:BMAX")
  field(DOL4, "XCOR:LI23:900:BMIN")
  field(DOL5, "XCOR:LI23:900:BMIN")
  field(DOL6, "XCOR:LI23:900:BMIN")
  field(LNK1, "XCOR:LI23:900:BMAGX.HOPR")
  field(LNK2, "XCOR:LI23:900:BMAGY.HOPR")
  field(LNK3, "XCOR:LI23:900:BLEM.HOPR")
  field(LNK4, "XCOR:LI23:900:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI23:900:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI23:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI23:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI23:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI23:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI23:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI23:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI23:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI23:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI23:900:EDES NPP MS")
  field(INPB, "XCOR:LI23:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI23:203:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI23:203:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI23:203:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI23:203:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI23:203:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI23:203:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI23:203:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI23:203:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI23:203:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI23:203:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI23:203:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI23:203:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI23:203:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI23:203:EDES.PROC PP")
    field(LNK2, "YCOR:LI23:203:EACT.PROC PP")
    field(LNK3, "YCOR:LI23:203:EERR.DISA PP")
    field(LNK4, "YCOR:LI23:203:ECON.PROC PP")
    field(LNK5, "YCOR:LI23:203:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI23:203:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI23:203:BLEM.PROC PP")
    field(LNK8, "YCOR:LI23:203:BMOD.PROC PP")
    field(LNK9, "YCOR:LI23:203:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI23:203:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI23:203:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI23:203:BMAX")
  field(DOL2, "YCOR:LI23:203:BMAX")
  field(DOL3, "YCOR:LI23:203:BMAX")
  field(DOL4, "YCOR:LI23:203:BMIN")
  field(DOL5, "YCOR:LI23:203:BMIN")
  field(DOL6, "YCOR:LI23:203:BMIN")
  field(LNK1, "YCOR:LI23:203:BMAGX.HOPR")
  field(LNK2, "YCOR:LI23:203:BMAGY.HOPR")
  field(LNK3, "YCOR:LI23:203:BLEM.HOPR")
  field(LNK4, "YCOR:LI23:203:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI23:203:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI23:203:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:203:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:203:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI23:203:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI23:203:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI23:203:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:203:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:203:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:203:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:203:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:203:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI23:203:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI23:203:EDES NPP MS")
  field(INPB, "YCOR:LI23:203:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI23:303:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI23:303:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI23:303:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI23:303:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI23:303:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI23:303:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI23:303:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI23:303:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI23:303:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI23:303:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI23:303:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI23:303:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI23:303:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI23:303:EDES.PROC PP")
    field(LNK2, "YCOR:LI23:303:EACT.PROC PP")
    field(LNK3, "YCOR:LI23:303:EERR.DISA PP")
    field(LNK4, "YCOR:LI23:303:ECON.PROC PP")
    field(LNK5, "YCOR:LI23:303:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI23:303:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI23:303:BLEM.PROC PP")
    field(LNK8, "YCOR:LI23:303:BMOD.PROC PP")
    field(LNK9, "YCOR:LI23:303:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI23:303:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI23:303:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI23:303:BMAX")
  field(DOL2, "YCOR:LI23:303:BMAX")
  field(DOL3, "YCOR:LI23:303:BMAX")
  field(DOL4, "YCOR:LI23:303:BMIN")
  field(DOL5, "YCOR:LI23:303:BMIN")
  field(DOL6, "YCOR:LI23:303:BMIN")
  field(LNK1, "YCOR:LI23:303:BMAGX.HOPR")
  field(LNK2, "YCOR:LI23:303:BMAGY.HOPR")
  field(LNK3, "YCOR:LI23:303:BLEM.HOPR")
  field(LNK4, "YCOR:LI23:303:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI23:303:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI23:303:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:303:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:303:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI23:303:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI23:303:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI23:303:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:303:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:303:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:303:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:303:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:303:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI23:303:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI23:303:EDES NPP MS")
  field(INPB, "YCOR:LI23:303:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI23:403:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI23:403:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI23:403:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI23:403:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI23:403:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI23:403:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI23:403:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI23:403:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI23:403:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI23:403:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI23:403:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI23:403:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI23:403:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI23:403:EDES.PROC PP")
    field(LNK2, "YCOR:LI23:403:EACT.PROC PP")
    field(LNK3, "YCOR:LI23:403:EERR.DISA PP")
    field(LNK4, "YCOR:LI23:403:ECON.PROC PP")
    field(LNK5, "YCOR:LI23:403:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI23:403:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI23:403:BLEM.PROC PP")
    field(LNK8, "YCOR:LI23:403:BMOD.PROC PP")
    field(LNK9, "YCOR:LI23:403:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI23:403:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI23:403:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI23:403:BMAX")
  field(DOL2, "YCOR:LI23:403:BMAX")
  field(DOL3, "YCOR:LI23:403:BMAX")
  field(DOL4, "YCOR:LI23:403:BMIN")
  field(DOL5, "YCOR:LI23:403:BMIN")
  field(DOL6, "YCOR:LI23:403:BMIN")
  field(LNK1, "YCOR:LI23:403:BMAGX.HOPR")
  field(LNK2, "YCOR:LI23:403:BMAGY.HOPR")
  field(LNK3, "YCOR:LI23:403:BLEM.HOPR")
  field(LNK4, "YCOR:LI23:403:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI23:403:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI23:403:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:403:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:403:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI23:403:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI23:403:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI23:403:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:403:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:403:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:403:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:403:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:403:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI23:403:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI23:403:EDES NPP MS")
  field(INPB, "YCOR:LI23:403:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI23:503:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI23:503:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI23:503:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI23:503:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI23:503:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI23:503:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI23:503:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI23:503:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI23:503:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI23:503:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI23:503:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI23:503:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI23:503:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI23:503:EDES.PROC PP")
    field(LNK2, "YCOR:LI23:503:EACT.PROC PP")
    field(LNK3, "YCOR:LI23:503:EERR.DISA PP")
    field(LNK4, "YCOR:LI23:503:ECON.PROC PP")
    field(LNK5, "YCOR:LI23:503:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI23:503:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI23:503:BLEM.PROC PP")
    field(LNK8, "YCOR:LI23:503:BMOD.PROC PP")
    field(LNK9, "YCOR:LI23:503:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI23:503:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI23:503:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI23:503:BMAX")
  field(DOL2, "YCOR:LI23:503:BMAX")
  field(DOL3, "YCOR:LI23:503:BMAX")
  field(DOL4, "YCOR:LI23:503:BMIN")
  field(DOL5, "YCOR:LI23:503:BMIN")
  field(DOL6, "YCOR:LI23:503:BMIN")
  field(LNK1, "YCOR:LI23:503:BMAGX.HOPR")
  field(LNK2, "YCOR:LI23:503:BMAGY.HOPR")
  field(LNK3, "YCOR:LI23:503:BLEM.HOPR")
  field(LNK4, "YCOR:LI23:503:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI23:503:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI23:503:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:503:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:503:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI23:503:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI23:503:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI23:503:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:503:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:503:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:503:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:503:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:503:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI23:503:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI23:503:EDES NPP MS")
  field(INPB, "YCOR:LI23:503:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI23:603:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI23:603:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI23:603:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI23:603:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI23:603:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI23:603:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI23:603:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI23:603:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI23:603:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI23:603:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI23:603:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI23:603:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI23:603:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI23:603:EDES.PROC PP")
    field(LNK2, "YCOR:LI23:603:EACT.PROC PP")
    field(LNK3, "YCOR:LI23:603:EERR.DISA PP")
    field(LNK4, "YCOR:LI23:603:ECON.PROC PP")
    field(LNK5, "YCOR:LI23:603:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI23:603:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI23:603:BLEM.PROC PP")
    field(LNK8, "YCOR:LI23:603:BMOD.PROC PP")
    field(LNK9, "YCOR:LI23:603:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI23:603:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI23:603:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI23:603:BMAX")
  field(DOL2, "YCOR:LI23:603:BMAX")
  field(DOL3, "YCOR:LI23:603:BMAX")
  field(DOL4, "YCOR:LI23:603:BMIN")
  field(DOL5, "YCOR:LI23:603:BMIN")
  field(DOL6, "YCOR:LI23:603:BMIN")
  field(LNK1, "YCOR:LI23:603:BMAGX.HOPR")
  field(LNK2, "YCOR:LI23:603:BMAGY.HOPR")
  field(LNK3, "YCOR:LI23:603:BLEM.HOPR")
  field(LNK4, "YCOR:LI23:603:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI23:603:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI23:603:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:603:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:603:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI23:603:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI23:603:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI23:603:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:603:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:603:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:603:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:603:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:603:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI23:603:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI23:603:EDES NPP MS")
  field(INPB, "YCOR:LI23:603:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI23:703:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI23:703:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI23:703:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI23:703:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI23:703:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI23:703:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI23:703:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI23:703:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI23:703:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI23:703:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI23:703:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI23:703:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI23:703:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI23:703:EDES.PROC PP")
    field(LNK2, "YCOR:LI23:703:EACT.PROC PP")
    field(LNK3, "YCOR:LI23:703:EERR.DISA PP")
    field(LNK4, "YCOR:LI23:703:ECON.PROC PP")
    field(LNK5, "YCOR:LI23:703:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI23:703:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI23:703:BLEM.PROC PP")
    field(LNK8, "YCOR:LI23:703:BMOD.PROC PP")
    field(LNK9, "YCOR:LI23:703:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI23:703:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI23:703:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI23:703:BMAX")
  field(DOL2, "YCOR:LI23:703:BMAX")
  field(DOL3, "YCOR:LI23:703:BMAX")
  field(DOL4, "YCOR:LI23:703:BMIN")
  field(DOL5, "YCOR:LI23:703:BMIN")
  field(DOL6, "YCOR:LI23:703:BMIN")
  field(LNK1, "YCOR:LI23:703:BMAGX.HOPR")
  field(LNK2, "YCOR:LI23:703:BMAGY.HOPR")
  field(LNK3, "YCOR:LI23:703:BLEM.HOPR")
  field(LNK4, "YCOR:LI23:703:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI23:703:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI23:703:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:703:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:703:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI23:703:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI23:703:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI23:703:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:703:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:703:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:703:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:703:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:703:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI23:703:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI23:703:EDES NPP MS")
  field(INPB, "YCOR:LI23:703:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI23:803:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI23:803:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI23:803:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI23:803:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI23:803:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI23:803:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI23:803:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI23:803:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI23:803:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI23:803:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI23:803:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI23:803:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI23:803:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI23:803:EDES.PROC PP")
    field(LNK2, "YCOR:LI23:803:EACT.PROC PP")
    field(LNK3, "YCOR:LI23:803:EERR.DISA PP")
    field(LNK4, "YCOR:LI23:803:ECON.PROC PP")
    field(LNK5, "YCOR:LI23:803:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI23:803:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI23:803:BLEM.PROC PP")
    field(LNK8, "YCOR:LI23:803:BMOD.PROC PP")
    field(LNK9, "YCOR:LI23:803:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI23:803:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI23:803:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI23:803:BMAX")
  field(DOL2, "YCOR:LI23:803:BMAX")
  field(DOL3, "YCOR:LI23:803:BMAX")
  field(DOL4, "YCOR:LI23:803:BMIN")
  field(DOL5, "YCOR:LI23:803:BMIN")
  field(DOL6, "YCOR:LI23:803:BMIN")
  field(LNK1, "YCOR:LI23:803:BMAGX.HOPR")
  field(LNK2, "YCOR:LI23:803:BMAGY.HOPR")
  field(LNK3, "YCOR:LI23:803:BLEM.HOPR")
  field(LNK4, "YCOR:LI23:803:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI23:803:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI23:803:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:803:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:803:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI23:803:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI23:803:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI23:803:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:803:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:803:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:803:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:803:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:803:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI23:803:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI23:803:EDES NPP MS")
  field(INPB, "YCOR:LI23:803:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI23:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI23:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI23:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI23:900:FUNC CA PP")
  field(DOL2, "MGNT:LI23:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI23:900:FUNC CA PP")
  field(DOL3, "MGNT:LI23:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI23:900:FUNC CA PP")
  field(DOL4, "MGNT:LI23:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI23:900:FUNC CA PP")
  field(DOL5, "MGNT:LI23:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI23:900:FUNC CA PP")
  field(DOL6, "MGNT:LI23:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI23:900:FUNC CA PP")
  field(DOL7, "MGNT:LI23:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI23:900:FUNC CA PP")
  field(DOL8, "MGNT:LI23:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI23:900:FUNC CA PP")
  field(DOL9, "MGNT:LI23:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI23:900:FUNC CA PP")
  field(DOLA, "MGNT:LI23:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI23:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI23:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI23:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI23:900:EDES.PROC PP")
    field(LNK2, "YCOR:LI23:900:EACT.PROC PP")
    field(LNK3, "YCOR:LI23:900:EERR.DISA PP")
    field(LNK4, "YCOR:LI23:900:ECON.PROC PP")
    field(LNK5, "YCOR:LI23:900:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI23:900:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI23:900:BLEM.PROC PP")
    field(LNK8, "YCOR:LI23:900:BMOD.PROC PP")
    field(LNK9, "YCOR:LI23:900:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI23:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI23:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI23:900:BMAX")
  field(DOL2, "YCOR:LI23:900:BMAX")
  field(DOL3, "YCOR:LI23:900:BMAX")
  field(DOL4, "YCOR:LI23:900:BMIN")
  field(DOL5, "YCOR:LI23:900:BMIN")
  field(DOL6, "YCOR:LI23:900:BMIN")
  field(LNK1, "YCOR:LI23:900:BMAGX.HOPR")
  field(LNK2, "YCOR:LI23:900:BMAGY.HOPR")
  field(LNK3, "YCOR:LI23:900:BLEM.HOPR")
  field(LNK4, "YCOR:LI23:900:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI23:900:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI23:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI23:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI23:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI23:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI23:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI23:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI23:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI23:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI23:900:EDES NPP MS")
  field(INPB, "YCOR:LI23:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:LI25:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:LI25:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:LI25:1:CTRL CA PP")
  field(LNK2, "MGNT:LI25:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:LI25:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:LI25:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:LI25:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:LI25:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:LI25:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:LI25:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:LI25:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:LI25:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:LI25:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:LI25:1:ALLSWITCH")
}

record(seq, "MGNT:LI25:1:ALLSWITCH") {
  field(DOL1, "MGNT:LI25:1:CTRL.FFVL")
  field(LNK1, "MGNT:LI25:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI25:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI25:1:CTRL")
}

record(bo, "MGNT:LI25:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:LI25:1:ALLSTARGO")
}

record(fanout, "MGNT:LI25:1:ALLSTARGO") {
  field(LNK1, "MGNT:LI25:1:ALLBENDSGO")
  field(LNK2, "MGNT:LI25:1:ALLBTRMSGO")
  field(LNK3, "MGNT:LI25:1:ALLLGPSSGO")
  field(LNK4, "MGNT:LI25:1:ALLQUADSGO")
  field(LNK5, "MGNT:LI25:1:ALLXCORSGO")
  field(LNK6, "MGNT:LI25:1:ALLYCORSGO")
  field(FLNK, "MGNT:LI25:1:ALLSTARGO_2")
}
record(fanout, "MGNT:LI25:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:LI25:1:ALLSOLNSGO")
  field(LNK2, "MGNT:LI25:1:ALLKICKSGO")
  field(LNK3, "MGNT:LI25:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:LI25:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:LI25:1:BENDSWITCH")
}

record(seq, "MGNT:LI25:1:BENDSWITCH") {
  field(DOL1, "MGNT:LI25:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:LI25:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI25:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI25:1:BENDCTRL")
}

record(seq, "MGNT:LI25:1:ALLBENDSGO") {
  field(DOL1, "MGNT:LI25:1:ALLSTAR")
  field(LNK1, "MGNT:LI25:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:LI25:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI25:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI25:1:BENDCTRL",20,10,0,0,"MGNT:LI25:1:BENDCTRL")
#! Field("MGNT:LI25:1:BENDCTRL.FLNK",16777215,1,"MGNT:LI25:1:BENDCTRL.FLNK")
#! Link("MGNT:LI25:1:BENDCTRL.FLNK","MGNT:LI25:1:BENDSWITCH")
#! Field("MGNT:LI25:1:BENDCTRL.FFVL",16777215,1,"MGNT:LI25:1:BENDCTRL.FFVL")
#! Record("MGNT:LI25:1:BENDSWITCH",460,322,0,0,"MGNT:LI25:1:BENDSWITCH")
#! Field("MGNT:LI25:1:BENDSWITCH.DOL1",16777215,0,"MGNT:LI25:1:BENDSWITCH.DOL1")
#! Link("MGNT:LI25:1:BENDSWITCH.DOL1","MGNT:LI25:1:BENDCTRL.FFVL")
#! Field("MGNT:LI25:1:BENDSWITCH.LNK1",16777215,1,"MGNT:LI25:1:BENDSWITCH.LNK1")
#! Field("MGNT:LI25:1:BENDSWITCH.FLNK",16777215,1,"MGNT:LI25:1:BENDSWITCH.FLNK")
#! Record("MGNT:LI25:1:ALLBENDSGO",240,96,0,0,"MGNT:LI25:1:ALLBENDSGO")
#! Field("MGNT:LI25:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:LI25:1:ALLBENDSGO.DOL1")
#! Field("MGNT:LI25:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:LI25:1:ALLBENDSGO.LNK1")
#! Link("MGNT:LI25:1:ALLBENDSGO.LNK1","MGNT:LI25:1:ALLBENDS.VAL")
#! Record("MGNT:LI25:1:ALLBENDS",540,102,0,0,"MGNT:LI25:1:ALLBENDS")
#! Field("MGNT:LI25:1:ALLBENDS.VAL",16777215,0,"MGNT:LI25:1:ALLBENDS.VAL")
#! Field("MGNT:LI25:1:ALLBENDS.FLNK",16777215,1,"MGNT:LI25:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:LI25:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI25:1:BTRMSWITCH")
}

record(seq, "MGNT:LI25:1:BTRMSWITCH") {
  field(DOL1, "MGNT:LI25:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:LI25:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI25:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI25:1:BTRMCTRL")
}

record(seq, "MGNT:LI25:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:LI25:1:ALLSTAR")
  field(LNK1, "MGNT:LI25:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:LI25:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI25:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI25:1:BTRMCTRL",20,10,0,0,"MGNT:LI25:1:BTRMCTRL")
#! Field("MGNT:LI25:1:BTRMCTRL.FLNK",16777215,1,"MGNT:LI25:1:BTRMCTRL.FLNK")
#! Link("MGNT:LI25:1:BTRMCTRL.FLNK","MGNT:LI25:1:BTRMSWITCH")
#! Field("MGNT:LI25:1:BTRMCTRL.FFVL",16777215,1,"MGNT:LI25:1:BTRMCTRL.FFVL")
#! Record("MGNT:LI25:1:BTRMSWITCH",460,322,0,0,"MGNT:LI25:1:BTRMSWITCH")
#! Field("MGNT:LI25:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:LI25:1:BTRMSWITCH.DOL1")
#! Link("MGNT:LI25:1:BTRMSWITCH.DOL1","MGNT:LI25:1:BTRMCTRL.FFVL")
#! Field("MGNT:LI25:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:LI25:1:BTRMSWITCH.LNK1")
#! Field("MGNT:LI25:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:LI25:1:BTRMSWITCH.FLNK")
#! Record("MGNT:LI25:1:ALLBTRMSGO",240,96,0,0,"MGNT:LI25:1:ALLBTRMSGO")
#! Field("MGNT:LI25:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:LI25:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:LI25:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:LI25:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:LI25:1:ALLBTRMSGO.LNK1","MGNT:LI25:1:ALLBTRMS.VAL")
#! Record("MGNT:LI25:1:ALLBTRMS",540,102,0,0,"MGNT:LI25:1:ALLBTRMS")
#! Field("MGNT:LI25:1:ALLBTRMS.VAL",16777215,0,"MGNT:LI25:1:ALLBTRMS.VAL")
#! Field("MGNT:LI25:1:ALLBTRMS.FLNK",16777215,1,"MGNT:LI25:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:LI25:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI25:1:LGPSSWITCH")
}

record(seq, "MGNT:LI25:1:LGPSSWITCH") {
  field(DOL1, "MGNT:LI25:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:LI25:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI25:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI25:1:LGPSCTRL")
}

record(seq, "MGNT:LI25:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:LI25:1:ALLSTAR")
  field(LNK1, "MGNT:LI25:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:LI25:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI25:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI25:1:LGPSCTRL",20,10,0,0,"MGNT:LI25:1:LGPSCTRL")
#! Field("MGNT:LI25:1:LGPSCTRL.FLNK",16777215,1,"MGNT:LI25:1:LGPSCTRL.FLNK")
#! Link("MGNT:LI25:1:LGPSCTRL.FLNK","MGNT:LI25:1:LGPSSWITCH")
#! Field("MGNT:LI25:1:LGPSCTRL.FFVL",16777215,1,"MGNT:LI25:1:LGPSCTRL.FFVL")
#! Record("MGNT:LI25:1:LGPSSWITCH",460,322,0,0,"MGNT:LI25:1:LGPSSWITCH")
#! Field("MGNT:LI25:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:LI25:1:LGPSSWITCH.DOL1")
#! Link("MGNT:LI25:1:LGPSSWITCH.DOL1","MGNT:LI25:1:LGPSCTRL.FFVL")
#! Field("MGNT:LI25:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:LI25:1:LGPSSWITCH.LNK1")
#! Field("MGNT:LI25:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:LI25:1:LGPSSWITCH.FLNK")
#! Record("MGNT:LI25:1:ALLLGPSSGO",240,96,0,0,"MGNT:LI25:1:ALLLGPSSGO")
#! Field("MGNT:LI25:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:LI25:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:LI25:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:LI25:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:LI25:1:ALLLGPSSGO.LNK1","MGNT:LI25:1:ALLLGPSS.VAL")
#! Record("MGNT:LI25:1:ALLLGPSS",540,102,0,0,"MGNT:LI25:1:ALLLGPSS")
#! Field("MGNT:LI25:1:ALLLGPSS.VAL",16777215,0,"MGNT:LI25:1:ALLLGPSS.VAL")
#! Field("MGNT:LI25:1:ALLLGPSS.FLNK",16777215,1,"MGNT:LI25:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:LI25:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:LI25:1:QUADSWITCH")
}

record(seq, "MGNT:LI25:1:QUADSWITCH") {
  field(DOL1, "MGNT:LI25:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:LI25:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI25:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI25:1:QUADCTRL")
}

record(seq, "MGNT:LI25:1:ALLQUADSGO") {
  field(DOL1, "MGNT:LI25:1:ALLSTAR")
  field(LNK1, "MGNT:LI25:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:LI25:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI25:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI25:1:QUADCTRL",20,10,0,0,"MGNT:LI25:1:QUADCTRL")
#! Field("MGNT:LI25:1:QUADCTRL.FLNK",16777215,1,"MGNT:LI25:1:QUADCTRL.FLNK")
#! Link("MGNT:LI25:1:QUADCTRL.FLNK","MGNT:LI25:1:QUADSWITCH")
#! Field("MGNT:LI25:1:QUADCTRL.FFVL",16777215,1,"MGNT:LI25:1:QUADCTRL.FFVL")
#! Record("MGNT:LI25:1:QUADSWITCH",460,322,0,0,"MGNT:LI25:1:QUADSWITCH")
#! Field("MGNT:LI25:1:QUADSWITCH.DOL1",16777215,0,"MGNT:LI25:1:QUADSWITCH.DOL1")
#! Link("MGNT:LI25:1:QUADSWITCH.DOL1","MGNT:LI25:1:QUADCTRL.FFVL")
#! Field("MGNT:LI25:1:QUADSWITCH.LNK1",16777215,1,"MGNT:LI25:1:QUADSWITCH.LNK1")
#! Field("MGNT:LI25:1:QUADSWITCH.FLNK",16777215,1,"MGNT:LI25:1:QUADSWITCH.FLNK")
#! Record("MGNT:LI25:1:ALLQUADSGO",240,96,0,0,"MGNT:LI25:1:ALLQUADSGO")
#! Field("MGNT:LI25:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:LI25:1:ALLQUADSGO.DOL1")
#! Field("MGNT:LI25:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:LI25:1:ALLQUADSGO.LNK1")
#! Link("MGNT:LI25:1:ALLQUADSGO.LNK1","MGNT:LI25:1:ALLQUADS.VAL")
#! Record("MGNT:LI25:1:ALLQUADS",540,102,0,0,"MGNT:LI25:1:ALLQUADS")
#! Field("MGNT:LI25:1:ALLQUADS.VAL",16777215,0,"MGNT:LI25:1:ALLQUADS.VAL")
#! Field("MGNT:LI25:1:ALLQUADS.FLNK",16777215,1,"MGNT:LI25:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:LI25:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:LI25:1:XCORSWITCH")
}

record(seq, "MGNT:LI25:1:XCORSWITCH") {
  field(DOL1, "MGNT:LI25:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:LI25:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI25:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI25:1:XCORCTRL")
}

record(seq, "MGNT:LI25:1:ALLXCORSGO") {
  field(DOL1, "MGNT:LI25:1:ALLSTAR")
  field(LNK1, "MGNT:LI25:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:LI25:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI25:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI25:1:XCORCTRL",20,10,0,0,"MGNT:LI25:1:XCORCTRL")
#! Field("MGNT:LI25:1:XCORCTRL.FLNK",16777215,1,"MGNT:LI25:1:XCORCTRL.FLNK")
#! Link("MGNT:LI25:1:XCORCTRL.FLNK","MGNT:LI25:1:XCORSWITCH")
#! Field("MGNT:LI25:1:XCORCTRL.FFVL",16777215,1,"MGNT:LI25:1:XCORCTRL.FFVL")
#! Record("MGNT:LI25:1:XCORSWITCH",460,322,0,0,"MGNT:LI25:1:XCORSWITCH")
#! Field("MGNT:LI25:1:XCORSWITCH.DOL1",16777215,0,"MGNT:LI25:1:XCORSWITCH.DOL1")
#! Link("MGNT:LI25:1:XCORSWITCH.DOL1","MGNT:LI25:1:XCORCTRL.FFVL")
#! Field("MGNT:LI25:1:XCORSWITCH.LNK1",16777215,1,"MGNT:LI25:1:XCORSWITCH.LNK1")
#! Field("MGNT:LI25:1:XCORSWITCH.FLNK",16777215,1,"MGNT:LI25:1:XCORSWITCH.FLNK")
#! Record("MGNT:LI25:1:ALLXCORSGO",240,96,0,0,"MGNT:LI25:1:ALLXCORSGO")
#! Field("MGNT:LI25:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:LI25:1:ALLXCORSGO.DOL1")
#! Field("MGNT:LI25:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:LI25:1:ALLXCORSGO.LNK1")
#! Link("MGNT:LI25:1:ALLXCORSGO.LNK1","MGNT:LI25:1:ALLXCORS.VAL")
#! Record("MGNT:LI25:1:ALLXCORS",540,102,0,0,"MGNT:LI25:1:ALLXCORS")
#! Field("MGNT:LI25:1:ALLXCORS.VAL",16777215,0,"MGNT:LI25:1:ALLXCORS.VAL")
#! Field("MGNT:LI25:1:ALLXCORS.FLNK",16777215,1,"MGNT:LI25:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:LI25:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:LI25:1:YCORSWITCH")
}

record(seq, "MGNT:LI25:1:YCORSWITCH") {
  field(DOL1, "MGNT:LI25:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:LI25:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI25:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI25:1:YCORCTRL")
}

record(seq, "MGNT:LI25:1:ALLYCORSGO") {
  field(DOL1, "MGNT:LI25:1:ALLSTAR")
  field(LNK1, "MGNT:LI25:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:LI25:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI25:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI25:1:YCORCTRL",20,10,0,0,"MGNT:LI25:1:YCORCTRL")
#! Field("MGNT:LI25:1:YCORCTRL.FLNK",16777215,1,"MGNT:LI25:1:YCORCTRL.FLNK")
#! Link("MGNT:LI25:1:YCORCTRL.FLNK","MGNT:LI25:1:YCORSWITCH")
#! Field("MGNT:LI25:1:YCORCTRL.FFVL",16777215,1,"MGNT:LI25:1:YCORCTRL.FFVL")
#! Record("MGNT:LI25:1:YCORSWITCH",460,322,0,0,"MGNT:LI25:1:YCORSWITCH")
#! Field("MGNT:LI25:1:YCORSWITCH.DOL1",16777215,0,"MGNT:LI25:1:YCORSWITCH.DOL1")
#! Link("MGNT:LI25:1:YCORSWITCH.DOL1","MGNT:LI25:1:YCORCTRL.FFVL")
#! Field("MGNT:LI25:1:YCORSWITCH.LNK1",16777215,1,"MGNT:LI25:1:YCORSWITCH.LNK1")
#! Field("MGNT:LI25:1:YCORSWITCH.FLNK",16777215,1,"MGNT:LI25:1:YCORSWITCH.FLNK")
#! Record("MGNT:LI25:1:ALLYCORSGO",240,96,0,0,"MGNT:LI25:1:ALLYCORSGO")
#! Field("MGNT:LI25:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:LI25:1:ALLYCORSGO.DOL1")
#! Field("MGNT:LI25:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:LI25:1:ALLYCORSGO.LNK1")
#! Link("MGNT:LI25:1:ALLYCORSGO.LNK1","MGNT:LI25:1:ALLYCORS.VAL")
#! Record("MGNT:LI25:1:ALLYCORS",540,102,0,0,"MGNT:LI25:1:ALLYCORS")
#! Field("MGNT:LI25:1:ALLYCORS.VAL",16777215,0,"MGNT:LI25:1:ALLYCORS.VAL")
#! Field("MGNT:LI25:1:ALLYCORS.FLNK",16777215,1,"MGNT:LI25:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:LI25:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:LI25:1:SOLNSWITCH")
}

record(seq, "MGNT:LI25:1:SOLNSWITCH") {
  field(DOL1, "MGNT:LI25:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:LI25:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI25:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI25:1:SOLNCTRL")
}

record(seq, "MGNT:LI25:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:LI25:1:ALLSTAR")
  field(LNK1, "MGNT:LI25:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:LI25:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI25:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI25:1:SOLNCTRL",20,10,0,0,"MGNT:LI25:1:SOLNCTRL")
#! Field("MGNT:LI25:1:SOLNCTRL.FLNK",16777215,1,"MGNT:LI25:1:SOLNCTRL.FLNK")
#! Link("MGNT:LI25:1:SOLNCTRL.FLNK","MGNT:LI25:1:SOLNSWITCH")
#! Field("MGNT:LI25:1:SOLNCTRL.FFVL",16777215,1,"MGNT:LI25:1:SOLNCTRL.FFVL")
#! Record("MGNT:LI25:1:SOLNSWITCH",460,322,0,0,"MGNT:LI25:1:SOLNSWITCH")
#! Field("MGNT:LI25:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:LI25:1:SOLNSWITCH.DOL1")
#! Link("MGNT:LI25:1:SOLNSWITCH.DOL1","MGNT:LI25:1:SOLNCTRL.FFVL")
#! Field("MGNT:LI25:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:LI25:1:SOLNSWITCH.LNK1")
#! Field("MGNT:LI25:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:LI25:1:SOLNSWITCH.FLNK")
#! Record("MGNT:LI25:1:ALLSOLNSGO",240,96,0,0,"MGNT:LI25:1:ALLSOLNSGO")
#! Field("MGNT:LI25:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:LI25:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:LI25:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:LI25:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:LI25:1:ALLSOLNSGO.LNK1","MGNT:LI25:1:ALLSOLNS.VAL")
#! Record("MGNT:LI25:1:ALLSOLNS",540,102,0,0,"MGNT:LI25:1:ALLSOLNS")
#! Field("MGNT:LI25:1:ALLSOLNS.VAL",16777215,0,"MGNT:LI25:1:ALLSOLNS.VAL")
#! Field("MGNT:LI25:1:ALLSOLNS.FLNK",16777215,1,"MGNT:LI25:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:LI25:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:LI25:1:KICKSWITCH")
}

record(seq, "MGNT:LI25:1:KICKSWITCH") {
  field(DOL1, "MGNT:LI25:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:LI25:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI25:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI25:1:KICKCTRL")
}

record(seq, "MGNT:LI25:1:ALLKICKSGO") {
  field(DOL1, "MGNT:LI25:1:ALLSTAR")
  field(LNK1, "MGNT:LI25:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:LI25:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI25:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI25:1:KICKCTRL",20,10,0,0,"MGNT:LI25:1:KICKCTRL")
#! Field("MGNT:LI25:1:KICKCTRL.FLNK",16777215,1,"MGNT:LI25:1:KICKCTRL.FLNK")
#! Link("MGNT:LI25:1:KICKCTRL.FLNK","MGNT:LI25:1:KICKSWITCH")
#! Field("MGNT:LI25:1:KICKCTRL.FFVL",16777215,1,"MGNT:LI25:1:KICKCTRL.FFVL")
#! Record("MGNT:LI25:1:KICKSWITCH",460,322,0,0,"MGNT:LI25:1:KICKSWITCH")
#! Field("MGNT:LI25:1:KICKSWITCH.DOL1",16777215,0,"MGNT:LI25:1:KICKSWITCH.DOL1")
#! Link("MGNT:LI25:1:KICKSWITCH.DOL1","MGNT:LI25:1:KICKCTRL.FFVL")
#! Field("MGNT:LI25:1:KICKSWITCH.LNK1",16777215,1,"MGNT:LI25:1:KICKSWITCH.LNK1")
#! Field("MGNT:LI25:1:KICKSWITCH.FLNK",16777215,1,"MGNT:LI25:1:KICKSWITCH.FLNK")
#! Record("MGNT:LI25:1:ALLKICKSGO",240,96,0,0,"MGNT:LI25:1:ALLKICKSGO")
#! Field("MGNT:LI25:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:LI25:1:ALLKICKSGO.DOL1")
#! Field("MGNT:LI25:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:LI25:1:ALLKICKSGO.LNK1")
#! Link("MGNT:LI25:1:ALLKICKSGO.LNK1","MGNT:LI25:1:ALLKICKS.VAL")
#! Record("MGNT:LI25:1:ALLKICKS",540,102,0,0,"MGNT:LI25:1:ALLKICKS")
#! Field("MGNT:LI25:1:ALLKICKS.VAL",16777215,0,"MGNT:LI25:1:ALLKICKS.VAL")
#! Field("MGNT:LI25:1:ALLKICKS.FLNK",16777215,1,"MGNT:LI25:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:LI25:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:LI25:1:SEXTSWITCH")
}

record(seq, "MGNT:LI25:1:SEXTSWITCH") {
  field(DOL1, "MGNT:LI25:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:LI25:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI25:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI25:1:SEXTCTRL")
}

record(seq, "MGNT:LI25:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:LI25:1:ALLSTAR")
  field(LNK1, "MGNT:LI25:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:LI25:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI25:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI25:1:SEXTCTRL",20,10,0,0,"MGNT:LI25:1:SEXTCTRL")
#! Field("MGNT:LI25:1:SEXTCTRL.FLNK",16777215,1,"MGNT:LI25:1:SEXTCTRL.FLNK")
#! Link("MGNT:LI25:1:SEXTCTRL.FLNK","MGNT:LI25:1:SEXTSWITCH")
#! Field("MGNT:LI25:1:SEXTCTRL.FFVL",16777215,1,"MGNT:LI25:1:SEXTCTRL.FFVL")
#! Record("MGNT:LI25:1:SEXTSWITCH",460,322,0,0,"MGNT:LI25:1:SEXTSWITCH")
#! Field("MGNT:LI25:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:LI25:1:SEXTSWITCH.DOL1")
#! Link("MGNT:LI25:1:SEXTSWITCH.DOL1","MGNT:LI25:1:SEXTCTRL.FFVL")
#! Field("MGNT:LI25:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:LI25:1:SEXTSWITCH.LNK1")
#! Field("MGNT:LI25:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:LI25:1:SEXTSWITCH.FLNK")
#! Record("MGNT:LI25:1:ALLSEXTSGO",240,96,0,0,"MGNT:LI25:1:ALLSEXTSGO")
#! Field("MGNT:LI25:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:LI25:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:LI25:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:LI25:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:LI25:1:ALLSEXTSGO.LNK1","MGNT:LI25:1:ALLSEXTS.VAL")
#! Record("MGNT:LI25:1:ALLSEXTS",540,102,0,0,"MGNT:LI25:1:ALLSEXTS")
#! Field("MGNT:LI25:1:ALLSEXTS.VAL",16777215,0,"MGNT:LI25:1:ALLSEXTS.VAL")
#! Field("MGNT:LI25:1:ALLSEXTS.FLNK",16777215,1,"MGNT:LI25:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record (seq, "MGNT:LI25:1:ALLBENDSSEL"){
}
record (seq, "MGNT:LI25:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:LI25:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:LI25:1:ALLKICKSSEL"){
}
record (seq, "MGNT:LI25:1:ALLSEXTSSEL"){
}

record (seq, "MGNT:LI25:1:ALLLGPSSSEL"){
  field (DOL1, "MGNT:LI25:1:ALLLGPSS")
  field (LNK1, "LGPS:LI25:2:SELECT CPP NMS")
}

record (seq, "MGNT:LI25:1:ALLQUADSSEL"){
  field (DOL1, "MGNT:LI25:1:ALLQUADS")
  field (DOL2, "MGNT:LI25:1:ALLQUADS")
  field (DOL3, "MGNT:LI25:1:ALLQUADS")
  field (DOL4, "MGNT:LI25:1:ALLQUADS")
  field (DOL5, "MGNT:LI25:1:ALLQUADS")
  field (DOL6, "MGNT:LI25:1:ALLQUADS")
  field (DOL7, "MGNT:LI25:1:ALLQUADS")
  field (DOL8, "MGNT:LI25:1:ALLQUADS")
  field (LNK1, "QUAD:LI25:201:SELECT CPP NMS")
  field (LNK2, "QUAD:LI25:301:SELECT CPP NMS")
  field (LNK3, "QUAD:LI25:401:SELECT CPP NMS")
  field (LNK4, "QUAD:LI25:501:SELECT CPP NMS")
  field (LNK5, "QUAD:LI25:601:SELECT CPP NMS")
  field (LNK6, "QUAD:LI25:701:SELECT CPP NMS")
  field (LNK7, "QUAD:LI25:801:SELECT CPP NMS")
  field (LNK8, "QUAD:LI25:901:SELECT CPP NMS")
}

record (seq, "MGNT:LI25:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:LI25:1:ALLXCORS")
  field (DOL2, "MGNT:LI25:1:ALLXCORS")
  field (DOL3, "MGNT:LI25:1:ALLXCORS")
  field (DOL4, "MGNT:LI25:1:ALLXCORS")
  field (DOL5, "MGNT:LI25:1:ALLXCORS")
  field (DOL6, "MGNT:LI25:1:ALLXCORS")
  field (DOL7, "MGNT:LI25:1:ALLXCORS")
  field (DOL8, "MGNT:LI25:1:ALLXCORS")
  field (LNK1, "XCOR:LI25:202:SELECT CPP NMS")
  field (LNK2, "XCOR:LI25:302:SELECT CPP NMS")
  field (LNK3, "XCOR:LI25:402:SELECT CPP NMS")
  field (LNK4, "XCOR:LI25:502:SELECT CPP NMS")
  field (LNK5, "XCOR:LI25:602:SELECT CPP NMS")
  field (LNK6, "XCOR:LI25:702:SELECT CPP NMS")
  field (LNK7, "XCOR:LI25:802:SELECT CPP NMS")
  field (LNK8, "XCOR:LI25:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI25:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:LI25:1:ALLYCORS")
  field (DOL2, "MGNT:LI25:1:ALLYCORS")
  field (DOL3, "MGNT:LI25:1:ALLYCORS")
  field (DOL4, "MGNT:LI25:1:ALLYCORS")
  field (DOL5, "MGNT:LI25:1:ALLYCORS")
  field (DOL6, "MGNT:LI25:1:ALLYCORS")
  field (DOL7, "MGNT:LI25:1:ALLYCORS")
  field (DOL8, "MGNT:LI25:1:ALLYCORS")
  field (LNK1, "YCOR:LI25:203:SELECT CPP NMS")
  field (LNK2, "YCOR:LI25:303:SELECT CPP NMS")
  field (LNK3, "YCOR:LI25:403:SELECT CPP NMS")
  field (LNK4, "YCOR:LI25:503:SELECT CPP NMS")
  field (LNK5, "YCOR:LI25:603:SELECT CPP NMS")
  field (LNK6, "YCOR:LI25:703:SELECT CPP NMS")
  field (LNK7, "YCOR:LI25:803:SELECT CPP NMS")
  field (LNK8, "YCOR:LI25:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI25:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (LNK1, "MGNT:LI25:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:LI25:1:QUADFUNCGO.PROC")
  field (LNK3, "MGNT:LI25:1:XCORFUNCGO.PROC")
  field (LNK4, "MGNT:LI25:1:YCORFUNCGO.PROC")
  field (LNK5, "MGNT:LI25:1:LGPSFUNCGO.PROC")
  field (LNK6, "MGNT:LI25:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:LI25:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI25:1:QUADFUNCGO") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI25:201:ALLFUNCGO")
  field (LNK2, "QUAD:LI25:301:ALLFUNCGO")
  field (LNK3, "QUAD:LI25:401:ALLFUNCGO")
  field (LNK4, "QUAD:LI25:501:ALLFUNCGO")
  field (LNK5, "QUAD:LI25:601:ALLFUNCGO")
  field (LNK6, "QUAD:LI25:701:ALLFUNCGO")
  field (FLNK, "MGNT:LI25:1:QUADFUNCGO1")
}

record (fanout, "MGNT:LI25:1:QUADFUNCGO1") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI25:801:ALLFUNCGO")
  field (LNK2, "QUAD:LI25:901:ALLFUNCGO")
  field (FLNK, "MGNT:LI25:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI25:1:XCORFUNCGO") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI25:202:ALLFUNCGO")
  field (LNK2, "XCOR:LI25:302:ALLFUNCGO")
  field (LNK3, "XCOR:LI25:402:ALLFUNCGO")
  field (LNK4, "XCOR:LI25:502:ALLFUNCGO")
  field (LNK5, "XCOR:LI25:602:ALLFUNCGO")
  field (LNK6, "XCOR:LI25:702:ALLFUNCGO")
  field (FLNK, "MGNT:LI25:1:XCORFUNCGO1")
}

record (fanout, "MGNT:LI25:1:XCORFUNCGO1") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI25:802:ALLFUNCGO")
  field (LNK2, "XCOR:LI25:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI25:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI25:1:YCORFUNCGO") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI25:203:ALLFUNCGO")
  field (LNK2, "YCOR:LI25:303:ALLFUNCGO")
  field (LNK3, "YCOR:LI25:403:ALLFUNCGO")
  field (LNK4, "YCOR:LI25:503:ALLFUNCGO")
  field (LNK5, "YCOR:LI25:603:ALLFUNCGO")
  field (LNK6, "YCOR:LI25:703:ALLFUNCGO")
  field (FLNK, "MGNT:LI25:1:YCORFUNCGO1")
}

record (fanout, "MGNT:LI25:1:YCORFUNCGO1") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI25:803:ALLFUNCGO")
  field (LNK2, "YCOR:LI25:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI25:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI25:1:LGPSFUNCGO"){
  field (DESC, "Process LGPS CTRL func")
  field (LNK1, "LGPS:LI25:2:ALLFUNCGO")
  field (FLNK, "MGNT:LI25:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI25:1:BENDFUNCGO"){
  field (DESC, "Process BEND CTRL func")
  field (FLNK, "MGNT:LI25:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI25:1:BTRMFUNCGO"){
  field (DESC, "Process BTRM CTRL func")
  field (FLNK, "MGNT:LI25:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI25:1:SOLNFUNCGO"){
  field (DESC, "Process SOLN CTRL func")
  field (FLNK, "MGNT:LI25:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI25:1:KICKFUNCGO"){
  field (DESC, "Process KICK CTRL func")
  field (FLNK, "MGNT:LI25:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI25:1:SEXTFUNCGO"){
  field (DESC, "Process SEXT CTRL func")
  field (FLNK, "MGNT:LI25:1:CTRLCLEAR")
}




#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LI25:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "LGPS:LI25:2:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LI25:2:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LI25:2:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LI25:2:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LI25:2:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LI25:2:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LI25:2:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LI25:2:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LI25:2:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LI25:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LI25:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LI25:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LI25:2:EDES.PROC PP")
    field(LNK2, "LGPS:LI25:2:EACT.PROC PP")
    field(LNK3, "LGPS:LI25:2:EERR.DISA PP")
    field(LNK4, "LGPS:LI25:2:ECON.PROC PP")
    field(LNK5, "LGPS:LI25:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:LI25:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:LI25:2:BLEM.PROC PP")
    field(LNK8, "LGPS:LI25:2:BMOD.PROC PP")
    field(LNK9, "LGPS:LI25:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LI25:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LI25:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LI25:2:BMAX")
  field(DOL2, "LGPS:LI25:2:BMAX")
  field(DOL3, "LGPS:LI25:2:BMAX")
  field(DOL4, "LGPS:LI25:2:BMIN")
  field(DOL5, "LGPS:LI25:2:BMIN")
  field(DOL6, "LGPS:LI25:2:BMIN")
  field(LNK1, "LGPS:LI25:2:BMAGX.HOPR")
  field(LNK2, "LGPS:LI25:2:BMAGY.HOPR")
  field(LNK3, "LGPS:LI25:2:BLEM.HOPR")
  field(LNK4, "LGPS:LI25:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LI25:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LI25:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LI25:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LI25:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LI25:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LI25:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LI25:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI25:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI25:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI25:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI25:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI25:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LI25:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LI25:2:EDES NPP MS")
  field(INPB, "LGPS:LI25:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI25:201:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI25:201:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI25:201:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI25:201:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI25:201:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI25:201:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI25:201:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI25:201:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI25:201:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI25:201:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI25:201:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI25:201:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI25:201:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI25:201:EDES.PROC PP")
    field(LNK2, "QUAD:LI25:201:EACT.PROC PP")
    field(LNK3, "QUAD:LI25:201:EERR.DISA PP")
    field(LNK4, "QUAD:LI25:201:ECON.PROC PP")
    field(LNK5, "QUAD:LI25:201:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI25:201:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI25:201:BLEM.PROC PP")
    field(LNK8, "QUAD:LI25:201:BMOD.PROC PP")
    field(LNK9, "QUAD:LI25:201:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI25:201:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI25:201:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI25:201:BMAX")
  field(DOL2, "QUAD:LI25:201:BMAX")
  field(DOL3, "QUAD:LI25:201:BMAX")
  field(DOL4, "QUAD:LI25:201:BMIN")
  field(DOL5, "QUAD:LI25:201:BMIN")
  field(DOL6, "QUAD:LI25:201:BMIN")
  field(LNK1, "QUAD:LI25:201:BMAGX.HOPR")
  field(LNK2, "QUAD:LI25:201:BMAGY.HOPR")
  field(LNK3, "QUAD:LI25:201:BLEM.HOPR")
  field(LNK4, "QUAD:LI25:201:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI25:201:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI25:201:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:201:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:201:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI25:201:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI25:201:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI25:201:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:201:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:201:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:201:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:201:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:201:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI25:201:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI25:201:EDES NPP MS")
  field(INPB, "QUAD:LI25:201:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI25:301:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI25:301:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI25:301:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI25:301:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI25:301:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI25:301:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI25:301:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI25:301:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI25:301:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI25:301:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI25:301:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI25:301:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI25:301:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI25:301:EDES.PROC PP")
    field(LNK2, "QUAD:LI25:301:EACT.PROC PP")
    field(LNK3, "QUAD:LI25:301:EERR.DISA PP")
    field(LNK4, "QUAD:LI25:301:ECON.PROC PP")
    field(LNK5, "QUAD:LI25:301:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI25:301:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI25:301:BLEM.PROC PP")
    field(LNK8, "QUAD:LI25:301:BMOD.PROC PP")
    field(LNK9, "QUAD:LI25:301:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI25:301:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI25:301:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI25:301:BMAX")
  field(DOL2, "QUAD:LI25:301:BMAX")
  field(DOL3, "QUAD:LI25:301:BMAX")
  field(DOL4, "QUAD:LI25:301:BMIN")
  field(DOL5, "QUAD:LI25:301:BMIN")
  field(DOL6, "QUAD:LI25:301:BMIN")
  field(LNK1, "QUAD:LI25:301:BMAGX.HOPR")
  field(LNK2, "QUAD:LI25:301:BMAGY.HOPR")
  field(LNK3, "QUAD:LI25:301:BLEM.HOPR")
  field(LNK4, "QUAD:LI25:301:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI25:301:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI25:301:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:301:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:301:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI25:301:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI25:301:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI25:301:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:301:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:301:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:301:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:301:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:301:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI25:301:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI25:301:EDES NPP MS")
  field(INPB, "QUAD:LI25:301:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI25:401:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI25:401:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI25:401:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI25:401:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI25:401:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI25:401:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI25:401:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI25:401:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI25:401:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI25:401:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI25:401:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI25:401:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI25:401:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI25:401:EDES.PROC PP")
    field(LNK2, "QUAD:LI25:401:EACT.PROC PP")
    field(LNK3, "QUAD:LI25:401:EERR.DISA PP")
    field(LNK4, "QUAD:LI25:401:ECON.PROC PP")
    field(LNK5, "QUAD:LI25:401:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI25:401:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI25:401:BLEM.PROC PP")
    field(LNK8, "QUAD:LI25:401:BMOD.PROC PP")
    field(LNK9, "QUAD:LI25:401:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI25:401:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI25:401:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI25:401:BMAX")
  field(DOL2, "QUAD:LI25:401:BMAX")
  field(DOL3, "QUAD:LI25:401:BMAX")
  field(DOL4, "QUAD:LI25:401:BMIN")
  field(DOL5, "QUAD:LI25:401:BMIN")
  field(DOL6, "QUAD:LI25:401:BMIN")
  field(LNK1, "QUAD:LI25:401:BMAGX.HOPR")
  field(LNK2, "QUAD:LI25:401:BMAGY.HOPR")
  field(LNK3, "QUAD:LI25:401:BLEM.HOPR")
  field(LNK4, "QUAD:LI25:401:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI25:401:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI25:401:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:401:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:401:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI25:401:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI25:401:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI25:401:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:401:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:401:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:401:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:401:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:401:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI25:401:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI25:401:EDES NPP MS")
  field(INPB, "QUAD:LI25:401:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI25:501:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI25:501:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI25:501:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI25:501:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI25:501:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI25:501:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI25:501:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI25:501:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI25:501:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI25:501:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI25:501:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI25:501:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI25:501:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI25:501:EDES.PROC PP")
    field(LNK2, "QUAD:LI25:501:EACT.PROC PP")
    field(LNK3, "QUAD:LI25:501:EERR.DISA PP")
    field(LNK4, "QUAD:LI25:501:ECON.PROC PP")
    field(LNK5, "QUAD:LI25:501:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI25:501:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI25:501:BLEM.PROC PP")
    field(LNK8, "QUAD:LI25:501:BMOD.PROC PP")
    field(LNK9, "QUAD:LI25:501:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI25:501:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI25:501:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI25:501:BMAX")
  field(DOL2, "QUAD:LI25:501:BMAX")
  field(DOL3, "QUAD:LI25:501:BMAX")
  field(DOL4, "QUAD:LI25:501:BMIN")
  field(DOL5, "QUAD:LI25:501:BMIN")
  field(DOL6, "QUAD:LI25:501:BMIN")
  field(LNK1, "QUAD:LI25:501:BMAGX.HOPR")
  field(LNK2, "QUAD:LI25:501:BMAGY.HOPR")
  field(LNK3, "QUAD:LI25:501:BLEM.HOPR")
  field(LNK4, "QUAD:LI25:501:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI25:501:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI25:501:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:501:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:501:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI25:501:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI25:501:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI25:501:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:501:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:501:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:501:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:501:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:501:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI25:501:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI25:501:EDES NPP MS")
  field(INPB, "QUAD:LI25:501:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI25:601:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI25:601:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI25:601:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI25:601:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI25:601:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI25:601:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI25:601:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI25:601:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI25:601:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI25:601:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI25:601:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI25:601:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI25:601:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI25:601:EDES.PROC PP")
    field(LNK2, "QUAD:LI25:601:EACT.PROC PP")
    field(LNK3, "QUAD:LI25:601:EERR.DISA PP")
    field(LNK4, "QUAD:LI25:601:ECON.PROC PP")
    field(LNK5, "QUAD:LI25:601:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI25:601:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI25:601:BLEM.PROC PP")
    field(LNK8, "QUAD:LI25:601:BMOD.PROC PP")
    field(LNK9, "QUAD:LI25:601:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI25:601:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI25:601:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI25:601:BMAX")
  field(DOL2, "QUAD:LI25:601:BMAX")
  field(DOL3, "QUAD:LI25:601:BMAX")
  field(DOL4, "QUAD:LI25:601:BMIN")
  field(DOL5, "QUAD:LI25:601:BMIN")
  field(DOL6, "QUAD:LI25:601:BMIN")
  field(LNK1, "QUAD:LI25:601:BMAGX.HOPR")
  field(LNK2, "QUAD:LI25:601:BMAGY.HOPR")
  field(LNK3, "QUAD:LI25:601:BLEM.HOPR")
  field(LNK4, "QUAD:LI25:601:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI25:601:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI25:601:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:601:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:601:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI25:601:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI25:601:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI25:601:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:601:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:601:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:601:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:601:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:601:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI25:601:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI25:601:EDES NPP MS")
  field(INPB, "QUAD:LI25:601:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI25:701:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI25:701:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI25:701:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI25:701:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI25:701:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI25:701:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI25:701:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI25:701:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI25:701:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI25:701:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI25:701:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI25:701:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI25:701:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI25:701:EDES.PROC PP")
    field(LNK2, "QUAD:LI25:701:EACT.PROC PP")
    field(LNK3, "QUAD:LI25:701:EERR.DISA PP")
    field(LNK4, "QUAD:LI25:701:ECON.PROC PP")
    field(LNK5, "QUAD:LI25:701:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI25:701:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI25:701:BLEM.PROC PP")
    field(LNK8, "QUAD:LI25:701:BMOD.PROC PP")
    field(LNK9, "QUAD:LI25:701:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI25:701:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI25:701:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI25:701:BMAX")
  field(DOL2, "QUAD:LI25:701:BMAX")
  field(DOL3, "QUAD:LI25:701:BMAX")
  field(DOL4, "QUAD:LI25:701:BMIN")
  field(DOL5, "QUAD:LI25:701:BMIN")
  field(DOL6, "QUAD:LI25:701:BMIN")
  field(LNK1, "QUAD:LI25:701:BMAGX.HOPR")
  field(LNK2, "QUAD:LI25:701:BMAGY.HOPR")
  field(LNK3, "QUAD:LI25:701:BLEM.HOPR")
  field(LNK4, "QUAD:LI25:701:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI25:701:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI25:701:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:701:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:701:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI25:701:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI25:701:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI25:701:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:701:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:701:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:701:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:701:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:701:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI25:701:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI25:701:EDES NPP MS")
  field(INPB, "QUAD:LI25:701:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI25:801:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI25:801:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI25:801:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI25:801:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI25:801:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI25:801:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI25:801:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI25:801:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI25:801:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI25:801:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI25:801:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI25:801:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI25:801:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI25:801:EDES.PROC PP")
    field(LNK2, "QUAD:LI25:801:EACT.PROC PP")
    field(LNK3, "QUAD:LI25:801:EERR.DISA PP")
    field(LNK4, "QUAD:LI25:801:ECON.PROC PP")
    field(LNK5, "QUAD:LI25:801:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI25:801:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI25:801:BLEM.PROC PP")
    field(LNK8, "QUAD:LI25:801:BMOD.PROC PP")
    field(LNK9, "QUAD:LI25:801:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI25:801:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI25:801:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI25:801:BMAX")
  field(DOL2, "QUAD:LI25:801:BMAX")
  field(DOL3, "QUAD:LI25:801:BMAX")
  field(DOL4, "QUAD:LI25:801:BMIN")
  field(DOL5, "QUAD:LI25:801:BMIN")
  field(DOL6, "QUAD:LI25:801:BMIN")
  field(LNK1, "QUAD:LI25:801:BMAGX.HOPR")
  field(LNK2, "QUAD:LI25:801:BMAGY.HOPR")
  field(LNK3, "QUAD:LI25:801:BLEM.HOPR")
  field(LNK4, "QUAD:LI25:801:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI25:801:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI25:801:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:801:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:801:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI25:801:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI25:801:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI25:801:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:801:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:801:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:801:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:801:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:801:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI25:801:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI25:801:EDES NPP MS")
  field(INPB, "QUAD:LI25:801:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI25:901:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI25:901:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI25:901:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI25:901:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI25:901:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI25:901:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI25:901:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI25:901:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI25:901:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI25:901:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI25:901:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI25:901:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI25:901:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI25:901:EDES.PROC PP")
    field(LNK2, "QUAD:LI25:901:EACT.PROC PP")
    field(LNK3, "QUAD:LI25:901:EERR.DISA PP")
    field(LNK4, "QUAD:LI25:901:ECON.PROC PP")
    field(LNK5, "QUAD:LI25:901:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI25:901:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI25:901:BLEM.PROC PP")
    field(LNK8, "QUAD:LI25:901:BMOD.PROC PP")
    field(LNK9, "QUAD:LI25:901:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI25:901:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI25:901:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI25:901:BMAX")
  field(DOL2, "QUAD:LI25:901:BMAX")
  field(DOL3, "QUAD:LI25:901:BMAX")
  field(DOL4, "QUAD:LI25:901:BMIN")
  field(DOL5, "QUAD:LI25:901:BMIN")
  field(DOL6, "QUAD:LI25:901:BMIN")
  field(LNK1, "QUAD:LI25:901:BMAGX.HOPR")
  field(LNK2, "QUAD:LI25:901:BMAGY.HOPR")
  field(LNK3, "QUAD:LI25:901:BLEM.HOPR")
  field(LNK4, "QUAD:LI25:901:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI25:901:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI25:901:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:901:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI25:901:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI25:901:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI25:901:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI25:901:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:901:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:901:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:901:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI25:901:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI25:901:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI25:901:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI25:901:EDES NPP MS")
  field(INPB, "QUAD:LI25:901:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI25:202:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI25:202:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI25:202:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI25:202:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI25:202:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI25:202:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI25:202:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI25:202:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI25:202:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI25:202:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI25:202:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI25:202:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI25:202:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI25:202:EDES.PROC PP")
    field(LNK2, "XCOR:LI25:202:EACT.PROC PP")
    field(LNK3, "XCOR:LI25:202:EERR.DISA PP")
    field(LNK4, "XCOR:LI25:202:ECON.PROC PP")
    field(LNK5, "XCOR:LI25:202:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI25:202:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI25:202:BLEM.PROC PP")
    field(LNK8, "XCOR:LI25:202:BMOD.PROC PP")
    field(LNK9, "XCOR:LI25:202:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI25:202:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI25:202:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI25:202:BMAX")
  field(DOL2, "XCOR:LI25:202:BMAX")
  field(DOL3, "XCOR:LI25:202:BMAX")
  field(DOL4, "XCOR:LI25:202:BMIN")
  field(DOL5, "XCOR:LI25:202:BMIN")
  field(DOL6, "XCOR:LI25:202:BMIN")
  field(LNK1, "XCOR:LI25:202:BMAGX.HOPR")
  field(LNK2, "XCOR:LI25:202:BMAGY.HOPR")
  field(LNK3, "XCOR:LI25:202:BLEM.HOPR")
  field(LNK4, "XCOR:LI25:202:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI25:202:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI25:202:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:202:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:202:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI25:202:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI25:202:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI25:202:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:202:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:202:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:202:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:202:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:202:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI25:202:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI25:202:EDES NPP MS")
  field(INPB, "XCOR:LI25:202:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI25:302:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI25:302:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI25:302:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI25:302:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI25:302:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI25:302:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI25:302:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI25:302:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI25:302:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI25:302:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI25:302:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI25:302:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI25:302:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI25:302:EDES.PROC PP")
    field(LNK2, "XCOR:LI25:302:EACT.PROC PP")
    field(LNK3, "XCOR:LI25:302:EERR.DISA PP")
    field(LNK4, "XCOR:LI25:302:ECON.PROC PP")
    field(LNK5, "XCOR:LI25:302:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI25:302:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI25:302:BLEM.PROC PP")
    field(LNK8, "XCOR:LI25:302:BMOD.PROC PP")
    field(LNK9, "XCOR:LI25:302:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI25:302:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI25:302:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI25:302:BMAX")
  field(DOL2, "XCOR:LI25:302:BMAX")
  field(DOL3, "XCOR:LI25:302:BMAX")
  field(DOL4, "XCOR:LI25:302:BMIN")
  field(DOL5, "XCOR:LI25:302:BMIN")
  field(DOL6, "XCOR:LI25:302:BMIN")
  field(LNK1, "XCOR:LI25:302:BMAGX.HOPR")
  field(LNK2, "XCOR:LI25:302:BMAGY.HOPR")
  field(LNK3, "XCOR:LI25:302:BLEM.HOPR")
  field(LNK4, "XCOR:LI25:302:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI25:302:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI25:302:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:302:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:302:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI25:302:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI25:302:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI25:302:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:302:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:302:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:302:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:302:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:302:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI25:302:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI25:302:EDES NPP MS")
  field(INPB, "XCOR:LI25:302:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI25:402:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI25:402:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI25:402:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI25:402:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI25:402:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI25:402:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI25:402:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI25:402:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI25:402:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI25:402:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI25:402:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI25:402:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI25:402:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI25:402:EDES.PROC PP")
    field(LNK2, "XCOR:LI25:402:EACT.PROC PP")
    field(LNK3, "XCOR:LI25:402:EERR.DISA PP")
    field(LNK4, "XCOR:LI25:402:ECON.PROC PP")
    field(LNK5, "XCOR:LI25:402:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI25:402:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI25:402:BLEM.PROC PP")
    field(LNK8, "XCOR:LI25:402:BMOD.PROC PP")
    field(LNK9, "XCOR:LI25:402:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI25:402:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI25:402:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI25:402:BMAX")
  field(DOL2, "XCOR:LI25:402:BMAX")
  field(DOL3, "XCOR:LI25:402:BMAX")
  field(DOL4, "XCOR:LI25:402:BMIN")
  field(DOL5, "XCOR:LI25:402:BMIN")
  field(DOL6, "XCOR:LI25:402:BMIN")
  field(LNK1, "XCOR:LI25:402:BMAGX.HOPR")
  field(LNK2, "XCOR:LI25:402:BMAGY.HOPR")
  field(LNK3, "XCOR:LI25:402:BLEM.HOPR")
  field(LNK4, "XCOR:LI25:402:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI25:402:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI25:402:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:402:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:402:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI25:402:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI25:402:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI25:402:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:402:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:402:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:402:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:402:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:402:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI25:402:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI25:402:EDES NPP MS")
  field(INPB, "XCOR:LI25:402:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI25:502:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI25:502:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI25:502:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI25:502:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI25:502:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI25:502:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI25:502:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI25:502:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI25:502:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI25:502:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI25:502:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI25:502:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI25:502:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI25:502:EDES.PROC PP")
    field(LNK2, "XCOR:LI25:502:EACT.PROC PP")
    field(LNK3, "XCOR:LI25:502:EERR.DISA PP")
    field(LNK4, "XCOR:LI25:502:ECON.PROC PP")
    field(LNK5, "XCOR:LI25:502:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI25:502:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI25:502:BLEM.PROC PP")
    field(LNK8, "XCOR:LI25:502:BMOD.PROC PP")
    field(LNK9, "XCOR:LI25:502:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI25:502:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI25:502:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI25:502:BMAX")
  field(DOL2, "XCOR:LI25:502:BMAX")
  field(DOL3, "XCOR:LI25:502:BMAX")
  field(DOL4, "XCOR:LI25:502:BMIN")
  field(DOL5, "XCOR:LI25:502:BMIN")
  field(DOL6, "XCOR:LI25:502:BMIN")
  field(LNK1, "XCOR:LI25:502:BMAGX.HOPR")
  field(LNK2, "XCOR:LI25:502:BMAGY.HOPR")
  field(LNK3, "XCOR:LI25:502:BLEM.HOPR")
  field(LNK4, "XCOR:LI25:502:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI25:502:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI25:502:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:502:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:502:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI25:502:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI25:502:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI25:502:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:502:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:502:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:502:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:502:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:502:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI25:502:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI25:502:EDES NPP MS")
  field(INPB, "XCOR:LI25:502:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI25:602:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI25:602:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI25:602:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI25:602:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI25:602:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI25:602:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI25:602:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI25:602:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI25:602:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI25:602:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI25:602:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI25:602:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI25:602:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI25:602:EDES.PROC PP")
    field(LNK2, "XCOR:LI25:602:EACT.PROC PP")
    field(LNK3, "XCOR:LI25:602:EERR.DISA PP")
    field(LNK4, "XCOR:LI25:602:ECON.PROC PP")
    field(LNK5, "XCOR:LI25:602:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI25:602:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI25:602:BLEM.PROC PP")
    field(LNK8, "XCOR:LI25:602:BMOD.PROC PP")
    field(LNK9, "XCOR:LI25:602:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI25:602:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI25:602:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI25:602:BMAX")
  field(DOL2, "XCOR:LI25:602:BMAX")
  field(DOL3, "XCOR:LI25:602:BMAX")
  field(DOL4, "XCOR:LI25:602:BMIN")
  field(DOL5, "XCOR:LI25:602:BMIN")
  field(DOL6, "XCOR:LI25:602:BMIN")
  field(LNK1, "XCOR:LI25:602:BMAGX.HOPR")
  field(LNK2, "XCOR:LI25:602:BMAGY.HOPR")
  field(LNK3, "XCOR:LI25:602:BLEM.HOPR")
  field(LNK4, "XCOR:LI25:602:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI25:602:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI25:602:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:602:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:602:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI25:602:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI25:602:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI25:602:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:602:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:602:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:602:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:602:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:602:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI25:602:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI25:602:EDES NPP MS")
  field(INPB, "XCOR:LI25:602:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI25:702:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI25:702:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI25:702:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI25:702:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI25:702:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI25:702:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI25:702:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI25:702:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI25:702:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI25:702:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI25:702:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI25:702:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI25:702:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI25:702:EDES.PROC PP")
    field(LNK2, "XCOR:LI25:702:EACT.PROC PP")
    field(LNK3, "XCOR:LI25:702:EERR.DISA PP")
    field(LNK4, "XCOR:LI25:702:ECON.PROC PP")
    field(LNK5, "XCOR:LI25:702:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI25:702:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI25:702:BLEM.PROC PP")
    field(LNK8, "XCOR:LI25:702:BMOD.PROC PP")
    field(LNK9, "XCOR:LI25:702:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI25:702:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI25:702:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI25:702:BMAX")
  field(DOL2, "XCOR:LI25:702:BMAX")
  field(DOL3, "XCOR:LI25:702:BMAX")
  field(DOL4, "XCOR:LI25:702:BMIN")
  field(DOL5, "XCOR:LI25:702:BMIN")
  field(DOL6, "XCOR:LI25:702:BMIN")
  field(LNK1, "XCOR:LI25:702:BMAGX.HOPR")
  field(LNK2, "XCOR:LI25:702:BMAGY.HOPR")
  field(LNK3, "XCOR:LI25:702:BLEM.HOPR")
  field(LNK4, "XCOR:LI25:702:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI25:702:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI25:702:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:702:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:702:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI25:702:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI25:702:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI25:702:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:702:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:702:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:702:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:702:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:702:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI25:702:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI25:702:EDES NPP MS")
  field(INPB, "XCOR:LI25:702:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI25:802:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI25:802:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI25:802:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI25:802:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI25:802:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI25:802:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI25:802:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI25:802:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI25:802:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI25:802:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI25:802:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI25:802:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI25:802:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI25:802:EDES.PROC PP")
    field(LNK2, "XCOR:LI25:802:EACT.PROC PP")
    field(LNK3, "XCOR:LI25:802:EERR.DISA PP")
    field(LNK4, "XCOR:LI25:802:ECON.PROC PP")
    field(LNK5, "XCOR:LI25:802:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI25:802:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI25:802:BLEM.PROC PP")
    field(LNK8, "XCOR:LI25:802:BMOD.PROC PP")
    field(LNK9, "XCOR:LI25:802:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI25:802:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI25:802:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI25:802:BMAX")
  field(DOL2, "XCOR:LI25:802:BMAX")
  field(DOL3, "XCOR:LI25:802:BMAX")
  field(DOL4, "XCOR:LI25:802:BMIN")
  field(DOL5, "XCOR:LI25:802:BMIN")
  field(DOL6, "XCOR:LI25:802:BMIN")
  field(LNK1, "XCOR:LI25:802:BMAGX.HOPR")
  field(LNK2, "XCOR:LI25:802:BMAGY.HOPR")
  field(LNK3, "XCOR:LI25:802:BLEM.HOPR")
  field(LNK4, "XCOR:LI25:802:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI25:802:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI25:802:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:802:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:802:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI25:802:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI25:802:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI25:802:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:802:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:802:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:802:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:802:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:802:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI25:802:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI25:802:EDES NPP MS")
  field(INPB, "XCOR:LI25:802:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI25:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI25:900:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI25:900:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI25:900:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI25:900:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI25:900:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI25:900:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI25:900:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI25:900:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI25:900:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI25:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI25:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI25:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI25:900:EDES.PROC PP")
    field(LNK2, "XCOR:LI25:900:EACT.PROC PP")
    field(LNK3, "XCOR:LI25:900:EERR.DISA PP")
    field(LNK4, "XCOR:LI25:900:ECON.PROC PP")
    field(LNK5, "XCOR:LI25:900:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI25:900:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI25:900:BLEM.PROC PP")
    field(LNK8, "XCOR:LI25:900:BMOD.PROC PP")
    field(LNK9, "XCOR:LI25:900:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI25:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI25:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI25:900:BMAX")
  field(DOL2, "XCOR:LI25:900:BMAX")
  field(DOL3, "XCOR:LI25:900:BMAX")
  field(DOL4, "XCOR:LI25:900:BMIN")
  field(DOL5, "XCOR:LI25:900:BMIN")
  field(DOL6, "XCOR:LI25:900:BMIN")
  field(LNK1, "XCOR:LI25:900:BMAGX.HOPR")
  field(LNK2, "XCOR:LI25:900:BMAGY.HOPR")
  field(LNK3, "XCOR:LI25:900:BLEM.HOPR")
  field(LNK4, "XCOR:LI25:900:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI25:900:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI25:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI25:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI25:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI25:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI25:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI25:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI25:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI25:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI25:900:EDES NPP MS")
  field(INPB, "XCOR:LI25:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI25:203:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI25:203:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI25:203:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI25:203:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI25:203:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI25:203:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI25:203:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI25:203:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI25:203:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI25:203:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI25:203:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI25:203:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI25:203:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI25:203:EDES.PROC PP")
    field(LNK2, "YCOR:LI25:203:EACT.PROC PP")
    field(LNK3, "YCOR:LI25:203:EERR.DISA PP")
    field(LNK4, "YCOR:LI25:203:ECON.PROC PP")
    field(LNK5, "YCOR:LI25:203:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI25:203:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI25:203:BLEM.PROC PP")
    field(LNK8, "YCOR:LI25:203:BMOD.PROC PP")
    field(LNK9, "YCOR:LI25:203:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI25:203:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI25:203:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI25:203:BMAX")
  field(DOL2, "YCOR:LI25:203:BMAX")
  field(DOL3, "YCOR:LI25:203:BMAX")
  field(DOL4, "YCOR:LI25:203:BMIN")
  field(DOL5, "YCOR:LI25:203:BMIN")
  field(DOL6, "YCOR:LI25:203:BMIN")
  field(LNK1, "YCOR:LI25:203:BMAGX.HOPR")
  field(LNK2, "YCOR:LI25:203:BMAGY.HOPR")
  field(LNK3, "YCOR:LI25:203:BLEM.HOPR")
  field(LNK4, "YCOR:LI25:203:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI25:203:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI25:203:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:203:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:203:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI25:203:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI25:203:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI25:203:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:203:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:203:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:203:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:203:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:203:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI25:203:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI25:203:EDES NPP MS")
  field(INPB, "YCOR:LI25:203:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI25:303:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI25:303:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI25:303:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI25:303:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI25:303:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI25:303:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI25:303:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI25:303:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI25:303:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI25:303:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI25:303:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI25:303:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI25:303:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI25:303:EDES.PROC PP")
    field(LNK2, "YCOR:LI25:303:EACT.PROC PP")
    field(LNK3, "YCOR:LI25:303:EERR.DISA PP")
    field(LNK4, "YCOR:LI25:303:ECON.PROC PP")
    field(LNK5, "YCOR:LI25:303:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI25:303:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI25:303:BLEM.PROC PP")
    field(LNK8, "YCOR:LI25:303:BMOD.PROC PP")
    field(LNK9, "YCOR:LI25:303:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI25:303:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI25:303:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI25:303:BMAX")
  field(DOL2, "YCOR:LI25:303:BMAX")
  field(DOL3, "YCOR:LI25:303:BMAX")
  field(DOL4, "YCOR:LI25:303:BMIN")
  field(DOL5, "YCOR:LI25:303:BMIN")
  field(DOL6, "YCOR:LI25:303:BMIN")
  field(LNK1, "YCOR:LI25:303:BMAGX.HOPR")
  field(LNK2, "YCOR:LI25:303:BMAGY.HOPR")
  field(LNK3, "YCOR:LI25:303:BLEM.HOPR")
  field(LNK4, "YCOR:LI25:303:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI25:303:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI25:303:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:303:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:303:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI25:303:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI25:303:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI25:303:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:303:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:303:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:303:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:303:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:303:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI25:303:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI25:303:EDES NPP MS")
  field(INPB, "YCOR:LI25:303:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI25:403:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI25:403:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI25:403:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI25:403:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI25:403:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI25:403:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI25:403:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI25:403:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI25:403:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI25:403:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI25:403:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI25:403:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI25:403:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI25:403:EDES.PROC PP")
    field(LNK2, "YCOR:LI25:403:EACT.PROC PP")
    field(LNK3, "YCOR:LI25:403:EERR.DISA PP")
    field(LNK4, "YCOR:LI25:403:ECON.PROC PP")
    field(LNK5, "YCOR:LI25:403:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI25:403:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI25:403:BLEM.PROC PP")
    field(LNK8, "YCOR:LI25:403:BMOD.PROC PP")
    field(LNK9, "YCOR:LI25:403:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI25:403:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI25:403:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI25:403:BMAX")
  field(DOL2, "YCOR:LI25:403:BMAX")
  field(DOL3, "YCOR:LI25:403:BMAX")
  field(DOL4, "YCOR:LI25:403:BMIN")
  field(DOL5, "YCOR:LI25:403:BMIN")
  field(DOL6, "YCOR:LI25:403:BMIN")
  field(LNK1, "YCOR:LI25:403:BMAGX.HOPR")
  field(LNK2, "YCOR:LI25:403:BMAGY.HOPR")
  field(LNK3, "YCOR:LI25:403:BLEM.HOPR")
  field(LNK4, "YCOR:LI25:403:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI25:403:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI25:403:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:403:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:403:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI25:403:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI25:403:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI25:403:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:403:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:403:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:403:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:403:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:403:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI25:403:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI25:403:EDES NPP MS")
  field(INPB, "YCOR:LI25:403:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI25:503:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI25:503:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI25:503:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI25:503:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI25:503:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI25:503:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI25:503:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI25:503:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI25:503:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI25:503:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI25:503:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI25:503:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI25:503:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI25:503:EDES.PROC PP")
    field(LNK2, "YCOR:LI25:503:EACT.PROC PP")
    field(LNK3, "YCOR:LI25:503:EERR.DISA PP")
    field(LNK4, "YCOR:LI25:503:ECON.PROC PP")
    field(LNK5, "YCOR:LI25:503:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI25:503:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI25:503:BLEM.PROC PP")
    field(LNK8, "YCOR:LI25:503:BMOD.PROC PP")
    field(LNK9, "YCOR:LI25:503:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI25:503:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI25:503:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI25:503:BMAX")
  field(DOL2, "YCOR:LI25:503:BMAX")
  field(DOL3, "YCOR:LI25:503:BMAX")
  field(DOL4, "YCOR:LI25:503:BMIN")
  field(DOL5, "YCOR:LI25:503:BMIN")
  field(DOL6, "YCOR:LI25:503:BMIN")
  field(LNK1, "YCOR:LI25:503:BMAGX.HOPR")
  field(LNK2, "YCOR:LI25:503:BMAGY.HOPR")
  field(LNK3, "YCOR:LI25:503:BLEM.HOPR")
  field(LNK4, "YCOR:LI25:503:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI25:503:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI25:503:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:503:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:503:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI25:503:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI25:503:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI25:503:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:503:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:503:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:503:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:503:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:503:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI25:503:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI25:503:EDES NPP MS")
  field(INPB, "YCOR:LI25:503:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI25:603:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI25:603:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI25:603:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI25:603:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI25:603:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI25:603:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI25:603:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI25:603:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI25:603:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI25:603:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI25:603:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI25:603:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI25:603:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI25:603:EDES.PROC PP")
    field(LNK2, "YCOR:LI25:603:EACT.PROC PP")
    field(LNK3, "YCOR:LI25:603:EERR.DISA PP")
    field(LNK4, "YCOR:LI25:603:ECON.PROC PP")
    field(LNK5, "YCOR:LI25:603:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI25:603:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI25:603:BLEM.PROC PP")
    field(LNK8, "YCOR:LI25:603:BMOD.PROC PP")
    field(LNK9, "YCOR:LI25:603:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI25:603:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI25:603:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI25:603:BMAX")
  field(DOL2, "YCOR:LI25:603:BMAX")
  field(DOL3, "YCOR:LI25:603:BMAX")
  field(DOL4, "YCOR:LI25:603:BMIN")
  field(DOL5, "YCOR:LI25:603:BMIN")
  field(DOL6, "YCOR:LI25:603:BMIN")
  field(LNK1, "YCOR:LI25:603:BMAGX.HOPR")
  field(LNK2, "YCOR:LI25:603:BMAGY.HOPR")
  field(LNK3, "YCOR:LI25:603:BLEM.HOPR")
  field(LNK4, "YCOR:LI25:603:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI25:603:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI25:603:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:603:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:603:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI25:603:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI25:603:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI25:603:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:603:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:603:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:603:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:603:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:603:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI25:603:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI25:603:EDES NPP MS")
  field(INPB, "YCOR:LI25:603:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI25:703:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI25:703:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI25:703:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI25:703:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI25:703:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI25:703:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI25:703:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI25:703:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI25:703:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI25:703:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI25:703:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI25:703:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI25:703:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI25:703:EDES.PROC PP")
    field(LNK2, "YCOR:LI25:703:EACT.PROC PP")
    field(LNK3, "YCOR:LI25:703:EERR.DISA PP")
    field(LNK4, "YCOR:LI25:703:ECON.PROC PP")
    field(LNK5, "YCOR:LI25:703:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI25:703:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI25:703:BLEM.PROC PP")
    field(LNK8, "YCOR:LI25:703:BMOD.PROC PP")
    field(LNK9, "YCOR:LI25:703:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI25:703:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI25:703:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI25:703:BMAX")
  field(DOL2, "YCOR:LI25:703:BMAX")
  field(DOL3, "YCOR:LI25:703:BMAX")
  field(DOL4, "YCOR:LI25:703:BMIN")
  field(DOL5, "YCOR:LI25:703:BMIN")
  field(DOL6, "YCOR:LI25:703:BMIN")
  field(LNK1, "YCOR:LI25:703:BMAGX.HOPR")
  field(LNK2, "YCOR:LI25:703:BMAGY.HOPR")
  field(LNK3, "YCOR:LI25:703:BLEM.HOPR")
  field(LNK4, "YCOR:LI25:703:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI25:703:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI25:703:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:703:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:703:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI25:703:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI25:703:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI25:703:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:703:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:703:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:703:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:703:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:703:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI25:703:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI25:703:EDES NPP MS")
  field(INPB, "YCOR:LI25:703:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI25:803:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI25:803:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI25:803:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI25:803:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI25:803:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI25:803:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI25:803:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI25:803:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI25:803:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI25:803:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI25:803:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI25:803:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI25:803:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI25:803:EDES.PROC PP")
    field(LNK2, "YCOR:LI25:803:EACT.PROC PP")
    field(LNK3, "YCOR:LI25:803:EERR.DISA PP")
    field(LNK4, "YCOR:LI25:803:ECON.PROC PP")
    field(LNK5, "YCOR:LI25:803:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI25:803:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI25:803:BLEM.PROC PP")
    field(LNK8, "YCOR:LI25:803:BMOD.PROC PP")
    field(LNK9, "YCOR:LI25:803:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI25:803:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI25:803:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI25:803:BMAX")
  field(DOL2, "YCOR:LI25:803:BMAX")
  field(DOL3, "YCOR:LI25:803:BMAX")
  field(DOL4, "YCOR:LI25:803:BMIN")
  field(DOL5, "YCOR:LI25:803:BMIN")
  field(DOL6, "YCOR:LI25:803:BMIN")
  field(LNK1, "YCOR:LI25:803:BMAGX.HOPR")
  field(LNK2, "YCOR:LI25:803:BMAGY.HOPR")
  field(LNK3, "YCOR:LI25:803:BLEM.HOPR")
  field(LNK4, "YCOR:LI25:803:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI25:803:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI25:803:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:803:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:803:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI25:803:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI25:803:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI25:803:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:803:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:803:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:803:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:803:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:803:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI25:803:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI25:803:EDES NPP MS")
  field(INPB, "YCOR:LI25:803:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI25:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI25:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI25:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI25:900:FUNC CA PP")
  field(DOL2, "MGNT:LI25:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI25:900:FUNC CA PP")
  field(DOL3, "MGNT:LI25:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI25:900:FUNC CA PP")
  field(DOL4, "MGNT:LI25:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI25:900:FUNC CA PP")
  field(DOL5, "MGNT:LI25:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI25:900:FUNC CA PP")
  field(DOL6, "MGNT:LI25:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI25:900:FUNC CA PP")
  field(DOL7, "MGNT:LI25:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI25:900:FUNC CA PP")
  field(DOL8, "MGNT:LI25:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI25:900:FUNC CA PP")
  field(DOL9, "MGNT:LI25:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI25:900:FUNC CA PP")
  field(DOLA, "MGNT:LI25:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI25:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI25:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI25:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI25:900:EDES.PROC PP")
    field(LNK2, "YCOR:LI25:900:EACT.PROC PP")
    field(LNK3, "YCOR:LI25:900:EERR.DISA PP")
    field(LNK4, "YCOR:LI25:900:ECON.PROC PP")
    field(LNK5, "YCOR:LI25:900:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI25:900:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI25:900:BLEM.PROC PP")
    field(LNK8, "YCOR:LI25:900:BMOD.PROC PP")
    field(LNK9, "YCOR:LI25:900:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI25:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI25:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI25:900:BMAX")
  field(DOL2, "YCOR:LI25:900:BMAX")
  field(DOL3, "YCOR:LI25:900:BMAX")
  field(DOL4, "YCOR:LI25:900:BMIN")
  field(DOL5, "YCOR:LI25:900:BMIN")
  field(DOL6, "YCOR:LI25:900:BMIN")
  field(LNK1, "YCOR:LI25:900:BMAGX.HOPR")
  field(LNK2, "YCOR:LI25:900:BMAGY.HOPR")
  field(LNK3, "YCOR:LI25:900:BLEM.HOPR")
  field(LNK4, "YCOR:LI25:900:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI25:900:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI25:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI25:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI25:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI25:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI25:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI25:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI25:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI25:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI25:900:EDES NPP MS")
  field(INPB, "YCOR:LI25:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:LI26:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:LI26:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:LI26:1:CTRL CA PP")
  field(LNK2, "MGNT:LI26:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:LI26:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:LI26:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:LI26:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:LI26:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:LI26:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:LI26:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:LI26:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:LI26:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:LI26:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:LI26:1:ALLSWITCH")
}

record(seq, "MGNT:LI26:1:ALLSWITCH") {
  field(DOL1, "MGNT:LI26:1:CTRL.FFVL")
  field(LNK1, "MGNT:LI26:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI26:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI26:1:CTRL")
}

record(bo, "MGNT:LI26:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:LI26:1:ALLSTARGO")
}

record(fanout, "MGNT:LI26:1:ALLSTARGO") {
  field(LNK1, "MGNT:LI26:1:ALLBENDSGO")
  field(LNK2, "MGNT:LI26:1:ALLBTRMSGO")
  field(LNK3, "MGNT:LI26:1:ALLLGPSSGO")
  field(LNK4, "MGNT:LI26:1:ALLQUADSGO")
  field(LNK5, "MGNT:LI26:1:ALLXCORSGO")
  field(LNK6, "MGNT:LI26:1:ALLYCORSGO")
  field(FLNK, "MGNT:LI26:1:ALLSTARGO_2")
}
record(fanout, "MGNT:LI26:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:LI26:1:ALLSOLNSGO")
  field(LNK2, "MGNT:LI26:1:ALLKICKSGO")
  field(LNK3, "MGNT:LI26:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:LI26:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:LI26:1:BENDSWITCH")
}

record(seq, "MGNT:LI26:1:BENDSWITCH") {
  field(DOL1, "MGNT:LI26:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:LI26:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI26:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI26:1:BENDCTRL")
}

record(seq, "MGNT:LI26:1:ALLBENDSGO") {
  field(DOL1, "MGNT:LI26:1:ALLSTAR")
  field(LNK1, "MGNT:LI26:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:LI26:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI26:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI26:1:BENDCTRL",20,10,0,0,"MGNT:LI26:1:BENDCTRL")
#! Field("MGNT:LI26:1:BENDCTRL.FLNK",16777215,1,"MGNT:LI26:1:BENDCTRL.FLNK")
#! Link("MGNT:LI26:1:BENDCTRL.FLNK","MGNT:LI26:1:BENDSWITCH")
#! Field("MGNT:LI26:1:BENDCTRL.FFVL",16777215,1,"MGNT:LI26:1:BENDCTRL.FFVL")
#! Record("MGNT:LI26:1:BENDSWITCH",460,322,0,0,"MGNT:LI26:1:BENDSWITCH")
#! Field("MGNT:LI26:1:BENDSWITCH.DOL1",16777215,0,"MGNT:LI26:1:BENDSWITCH.DOL1")
#! Link("MGNT:LI26:1:BENDSWITCH.DOL1","MGNT:LI26:1:BENDCTRL.FFVL")
#! Field("MGNT:LI26:1:BENDSWITCH.LNK1",16777215,1,"MGNT:LI26:1:BENDSWITCH.LNK1")
#! Field("MGNT:LI26:1:BENDSWITCH.FLNK",16777215,1,"MGNT:LI26:1:BENDSWITCH.FLNK")
#! Record("MGNT:LI26:1:ALLBENDSGO",240,96,0,0,"MGNT:LI26:1:ALLBENDSGO")
#! Field("MGNT:LI26:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:LI26:1:ALLBENDSGO.DOL1")
#! Field("MGNT:LI26:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:LI26:1:ALLBENDSGO.LNK1")
#! Link("MGNT:LI26:1:ALLBENDSGO.LNK1","MGNT:LI26:1:ALLBENDS.VAL")
#! Record("MGNT:LI26:1:ALLBENDS",540,102,0,0,"MGNT:LI26:1:ALLBENDS")
#! Field("MGNT:LI26:1:ALLBENDS.VAL",16777215,0,"MGNT:LI26:1:ALLBENDS.VAL")
#! Field("MGNT:LI26:1:ALLBENDS.FLNK",16777215,1,"MGNT:LI26:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:LI26:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI26:1:BTRMSWITCH")
}

record(seq, "MGNT:LI26:1:BTRMSWITCH") {
  field(DOL1, "MGNT:LI26:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:LI26:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI26:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI26:1:BTRMCTRL")
}

record(seq, "MGNT:LI26:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:LI26:1:ALLSTAR")
  field(LNK1, "MGNT:LI26:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:LI26:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI26:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI26:1:BTRMCTRL",20,10,0,0,"MGNT:LI26:1:BTRMCTRL")
#! Field("MGNT:LI26:1:BTRMCTRL.FLNK",16777215,1,"MGNT:LI26:1:BTRMCTRL.FLNK")
#! Link("MGNT:LI26:1:BTRMCTRL.FLNK","MGNT:LI26:1:BTRMSWITCH")
#! Field("MGNT:LI26:1:BTRMCTRL.FFVL",16777215,1,"MGNT:LI26:1:BTRMCTRL.FFVL")
#! Record("MGNT:LI26:1:BTRMSWITCH",460,322,0,0,"MGNT:LI26:1:BTRMSWITCH")
#! Field("MGNT:LI26:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:LI26:1:BTRMSWITCH.DOL1")
#! Link("MGNT:LI26:1:BTRMSWITCH.DOL1","MGNT:LI26:1:BTRMCTRL.FFVL")
#! Field("MGNT:LI26:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:LI26:1:BTRMSWITCH.LNK1")
#! Field("MGNT:LI26:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:LI26:1:BTRMSWITCH.FLNK")
#! Record("MGNT:LI26:1:ALLBTRMSGO",240,96,0,0,"MGNT:LI26:1:ALLBTRMSGO")
#! Field("MGNT:LI26:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:LI26:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:LI26:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:LI26:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:LI26:1:ALLBTRMSGO.LNK1","MGNT:LI26:1:ALLBTRMS.VAL")
#! Record("MGNT:LI26:1:ALLBTRMS",540,102,0,0,"MGNT:LI26:1:ALLBTRMS")
#! Field("MGNT:LI26:1:ALLBTRMS.VAL",16777215,0,"MGNT:LI26:1:ALLBTRMS.VAL")
#! Field("MGNT:LI26:1:ALLBTRMS.FLNK",16777215,1,"MGNT:LI26:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:LI26:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI26:1:LGPSSWITCH")
}

record(seq, "MGNT:LI26:1:LGPSSWITCH") {
  field(DOL1, "MGNT:LI26:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:LI26:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI26:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI26:1:LGPSCTRL")
}

record(seq, "MGNT:LI26:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:LI26:1:ALLSTAR")
  field(LNK1, "MGNT:LI26:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:LI26:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI26:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI26:1:LGPSCTRL",20,10,0,0,"MGNT:LI26:1:LGPSCTRL")
#! Field("MGNT:LI26:1:LGPSCTRL.FLNK",16777215,1,"MGNT:LI26:1:LGPSCTRL.FLNK")
#! Link("MGNT:LI26:1:LGPSCTRL.FLNK","MGNT:LI26:1:LGPSSWITCH")
#! Field("MGNT:LI26:1:LGPSCTRL.FFVL",16777215,1,"MGNT:LI26:1:LGPSCTRL.FFVL")
#! Record("MGNT:LI26:1:LGPSSWITCH",460,322,0,0,"MGNT:LI26:1:LGPSSWITCH")
#! Field("MGNT:LI26:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:LI26:1:LGPSSWITCH.DOL1")
#! Link("MGNT:LI26:1:LGPSSWITCH.DOL1","MGNT:LI26:1:LGPSCTRL.FFVL")
#! Field("MGNT:LI26:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:LI26:1:LGPSSWITCH.LNK1")
#! Field("MGNT:LI26:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:LI26:1:LGPSSWITCH.FLNK")
#! Record("MGNT:LI26:1:ALLLGPSSGO",240,96,0,0,"MGNT:LI26:1:ALLLGPSSGO")
#! Field("MGNT:LI26:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:LI26:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:LI26:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:LI26:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:LI26:1:ALLLGPSSGO.LNK1","MGNT:LI26:1:ALLLGPSS.VAL")
#! Record("MGNT:LI26:1:ALLLGPSS",540,102,0,0,"MGNT:LI26:1:ALLLGPSS")
#! Field("MGNT:LI26:1:ALLLGPSS.VAL",16777215,0,"MGNT:LI26:1:ALLLGPSS.VAL")
#! Field("MGNT:LI26:1:ALLLGPSS.FLNK",16777215,1,"MGNT:LI26:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:LI26:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:LI26:1:QUADSWITCH")
}

record(seq, "MGNT:LI26:1:QUADSWITCH") {
  field(DOL1, "MGNT:LI26:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:LI26:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI26:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI26:1:QUADCTRL")
}

record(seq, "MGNT:LI26:1:ALLQUADSGO") {
  field(DOL1, "MGNT:LI26:1:ALLSTAR")
  field(LNK1, "MGNT:LI26:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:LI26:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI26:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI26:1:QUADCTRL",20,10,0,0,"MGNT:LI26:1:QUADCTRL")
#! Field("MGNT:LI26:1:QUADCTRL.FLNK",16777215,1,"MGNT:LI26:1:QUADCTRL.FLNK")
#! Link("MGNT:LI26:1:QUADCTRL.FLNK","MGNT:LI26:1:QUADSWITCH")
#! Field("MGNT:LI26:1:QUADCTRL.FFVL",16777215,1,"MGNT:LI26:1:QUADCTRL.FFVL")
#! Record("MGNT:LI26:1:QUADSWITCH",460,322,0,0,"MGNT:LI26:1:QUADSWITCH")
#! Field("MGNT:LI26:1:QUADSWITCH.DOL1",16777215,0,"MGNT:LI26:1:QUADSWITCH.DOL1")
#! Link("MGNT:LI26:1:QUADSWITCH.DOL1","MGNT:LI26:1:QUADCTRL.FFVL")
#! Field("MGNT:LI26:1:QUADSWITCH.LNK1",16777215,1,"MGNT:LI26:1:QUADSWITCH.LNK1")
#! Field("MGNT:LI26:1:QUADSWITCH.FLNK",16777215,1,"MGNT:LI26:1:QUADSWITCH.FLNK")
#! Record("MGNT:LI26:1:ALLQUADSGO",240,96,0,0,"MGNT:LI26:1:ALLQUADSGO")
#! Field("MGNT:LI26:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:LI26:1:ALLQUADSGO.DOL1")
#! Field("MGNT:LI26:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:LI26:1:ALLQUADSGO.LNK1")
#! Link("MGNT:LI26:1:ALLQUADSGO.LNK1","MGNT:LI26:1:ALLQUADS.VAL")
#! Record("MGNT:LI26:1:ALLQUADS",540,102,0,0,"MGNT:LI26:1:ALLQUADS")
#! Field("MGNT:LI26:1:ALLQUADS.VAL",16777215,0,"MGNT:LI26:1:ALLQUADS.VAL")
#! Field("MGNT:LI26:1:ALLQUADS.FLNK",16777215,1,"MGNT:LI26:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:LI26:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:LI26:1:XCORSWITCH")
}

record(seq, "MGNT:LI26:1:XCORSWITCH") {
  field(DOL1, "MGNT:LI26:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:LI26:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI26:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI26:1:XCORCTRL")
}

record(seq, "MGNT:LI26:1:ALLXCORSGO") {
  field(DOL1, "MGNT:LI26:1:ALLSTAR")
  field(LNK1, "MGNT:LI26:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:LI26:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI26:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI26:1:XCORCTRL",20,10,0,0,"MGNT:LI26:1:XCORCTRL")
#! Field("MGNT:LI26:1:XCORCTRL.FLNK",16777215,1,"MGNT:LI26:1:XCORCTRL.FLNK")
#! Link("MGNT:LI26:1:XCORCTRL.FLNK","MGNT:LI26:1:XCORSWITCH")
#! Field("MGNT:LI26:1:XCORCTRL.FFVL",16777215,1,"MGNT:LI26:1:XCORCTRL.FFVL")
#! Record("MGNT:LI26:1:XCORSWITCH",460,322,0,0,"MGNT:LI26:1:XCORSWITCH")
#! Field("MGNT:LI26:1:XCORSWITCH.DOL1",16777215,0,"MGNT:LI26:1:XCORSWITCH.DOL1")
#! Link("MGNT:LI26:1:XCORSWITCH.DOL1","MGNT:LI26:1:XCORCTRL.FFVL")
#! Field("MGNT:LI26:1:XCORSWITCH.LNK1",16777215,1,"MGNT:LI26:1:XCORSWITCH.LNK1")
#! Field("MGNT:LI26:1:XCORSWITCH.FLNK",16777215,1,"MGNT:LI26:1:XCORSWITCH.FLNK")
#! Record("MGNT:LI26:1:ALLXCORSGO",240,96,0,0,"MGNT:LI26:1:ALLXCORSGO")
#! Field("MGNT:LI26:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:LI26:1:ALLXCORSGO.DOL1")
#! Field("MGNT:LI26:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:LI26:1:ALLXCORSGO.LNK1")
#! Link("MGNT:LI26:1:ALLXCORSGO.LNK1","MGNT:LI26:1:ALLXCORS.VAL")
#! Record("MGNT:LI26:1:ALLXCORS",540,102,0,0,"MGNT:LI26:1:ALLXCORS")
#! Field("MGNT:LI26:1:ALLXCORS.VAL",16777215,0,"MGNT:LI26:1:ALLXCORS.VAL")
#! Field("MGNT:LI26:1:ALLXCORS.FLNK",16777215,1,"MGNT:LI26:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:LI26:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:LI26:1:YCORSWITCH")
}

record(seq, "MGNT:LI26:1:YCORSWITCH") {
  field(DOL1, "MGNT:LI26:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:LI26:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI26:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI26:1:YCORCTRL")
}

record(seq, "MGNT:LI26:1:ALLYCORSGO") {
  field(DOL1, "MGNT:LI26:1:ALLSTAR")
  field(LNK1, "MGNT:LI26:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:LI26:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI26:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI26:1:YCORCTRL",20,10,0,0,"MGNT:LI26:1:YCORCTRL")
#! Field("MGNT:LI26:1:YCORCTRL.FLNK",16777215,1,"MGNT:LI26:1:YCORCTRL.FLNK")
#! Link("MGNT:LI26:1:YCORCTRL.FLNK","MGNT:LI26:1:YCORSWITCH")
#! Field("MGNT:LI26:1:YCORCTRL.FFVL",16777215,1,"MGNT:LI26:1:YCORCTRL.FFVL")
#! Record("MGNT:LI26:1:YCORSWITCH",460,322,0,0,"MGNT:LI26:1:YCORSWITCH")
#! Field("MGNT:LI26:1:YCORSWITCH.DOL1",16777215,0,"MGNT:LI26:1:YCORSWITCH.DOL1")
#! Link("MGNT:LI26:1:YCORSWITCH.DOL1","MGNT:LI26:1:YCORCTRL.FFVL")
#! Field("MGNT:LI26:1:YCORSWITCH.LNK1",16777215,1,"MGNT:LI26:1:YCORSWITCH.LNK1")
#! Field("MGNT:LI26:1:YCORSWITCH.FLNK",16777215,1,"MGNT:LI26:1:YCORSWITCH.FLNK")
#! Record("MGNT:LI26:1:ALLYCORSGO",240,96,0,0,"MGNT:LI26:1:ALLYCORSGO")
#! Field("MGNT:LI26:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:LI26:1:ALLYCORSGO.DOL1")
#! Field("MGNT:LI26:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:LI26:1:ALLYCORSGO.LNK1")
#! Link("MGNT:LI26:1:ALLYCORSGO.LNK1","MGNT:LI26:1:ALLYCORS.VAL")
#! Record("MGNT:LI26:1:ALLYCORS",540,102,0,0,"MGNT:LI26:1:ALLYCORS")
#! Field("MGNT:LI26:1:ALLYCORS.VAL",16777215,0,"MGNT:LI26:1:ALLYCORS.VAL")
#! Field("MGNT:LI26:1:ALLYCORS.FLNK",16777215,1,"MGNT:LI26:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:LI26:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:LI26:1:SOLNSWITCH")
}

record(seq, "MGNT:LI26:1:SOLNSWITCH") {
  field(DOL1, "MGNT:LI26:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:LI26:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI26:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI26:1:SOLNCTRL")
}

record(seq, "MGNT:LI26:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:LI26:1:ALLSTAR")
  field(LNK1, "MGNT:LI26:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:LI26:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI26:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI26:1:SOLNCTRL",20,10,0,0,"MGNT:LI26:1:SOLNCTRL")
#! Field("MGNT:LI26:1:SOLNCTRL.FLNK",16777215,1,"MGNT:LI26:1:SOLNCTRL.FLNK")
#! Link("MGNT:LI26:1:SOLNCTRL.FLNK","MGNT:LI26:1:SOLNSWITCH")
#! Field("MGNT:LI26:1:SOLNCTRL.FFVL",16777215,1,"MGNT:LI26:1:SOLNCTRL.FFVL")
#! Record("MGNT:LI26:1:SOLNSWITCH",460,322,0,0,"MGNT:LI26:1:SOLNSWITCH")
#! Field("MGNT:LI26:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:LI26:1:SOLNSWITCH.DOL1")
#! Link("MGNT:LI26:1:SOLNSWITCH.DOL1","MGNT:LI26:1:SOLNCTRL.FFVL")
#! Field("MGNT:LI26:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:LI26:1:SOLNSWITCH.LNK1")
#! Field("MGNT:LI26:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:LI26:1:SOLNSWITCH.FLNK")
#! Record("MGNT:LI26:1:ALLSOLNSGO",240,96,0,0,"MGNT:LI26:1:ALLSOLNSGO")
#! Field("MGNT:LI26:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:LI26:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:LI26:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:LI26:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:LI26:1:ALLSOLNSGO.LNK1","MGNT:LI26:1:ALLSOLNS.VAL")
#! Record("MGNT:LI26:1:ALLSOLNS",540,102,0,0,"MGNT:LI26:1:ALLSOLNS")
#! Field("MGNT:LI26:1:ALLSOLNS.VAL",16777215,0,"MGNT:LI26:1:ALLSOLNS.VAL")
#! Field("MGNT:LI26:1:ALLSOLNS.FLNK",16777215,1,"MGNT:LI26:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:LI26:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:LI26:1:KICKSWITCH")
}

record(seq, "MGNT:LI26:1:KICKSWITCH") {
  field(DOL1, "MGNT:LI26:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:LI26:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI26:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI26:1:KICKCTRL")
}

record(seq, "MGNT:LI26:1:ALLKICKSGO") {
  field(DOL1, "MGNT:LI26:1:ALLSTAR")
  field(LNK1, "MGNT:LI26:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:LI26:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI26:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI26:1:KICKCTRL",20,10,0,0,"MGNT:LI26:1:KICKCTRL")
#! Field("MGNT:LI26:1:KICKCTRL.FLNK",16777215,1,"MGNT:LI26:1:KICKCTRL.FLNK")
#! Link("MGNT:LI26:1:KICKCTRL.FLNK","MGNT:LI26:1:KICKSWITCH")
#! Field("MGNT:LI26:1:KICKCTRL.FFVL",16777215,1,"MGNT:LI26:1:KICKCTRL.FFVL")
#! Record("MGNT:LI26:1:KICKSWITCH",460,322,0,0,"MGNT:LI26:1:KICKSWITCH")
#! Field("MGNT:LI26:1:KICKSWITCH.DOL1",16777215,0,"MGNT:LI26:1:KICKSWITCH.DOL1")
#! Link("MGNT:LI26:1:KICKSWITCH.DOL1","MGNT:LI26:1:KICKCTRL.FFVL")
#! Field("MGNT:LI26:1:KICKSWITCH.LNK1",16777215,1,"MGNT:LI26:1:KICKSWITCH.LNK1")
#! Field("MGNT:LI26:1:KICKSWITCH.FLNK",16777215,1,"MGNT:LI26:1:KICKSWITCH.FLNK")
#! Record("MGNT:LI26:1:ALLKICKSGO",240,96,0,0,"MGNT:LI26:1:ALLKICKSGO")
#! Field("MGNT:LI26:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:LI26:1:ALLKICKSGO.DOL1")
#! Field("MGNT:LI26:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:LI26:1:ALLKICKSGO.LNK1")
#! Link("MGNT:LI26:1:ALLKICKSGO.LNK1","MGNT:LI26:1:ALLKICKS.VAL")
#! Record("MGNT:LI26:1:ALLKICKS",540,102,0,0,"MGNT:LI26:1:ALLKICKS")
#! Field("MGNT:LI26:1:ALLKICKS.VAL",16777215,0,"MGNT:LI26:1:ALLKICKS.VAL")
#! Field("MGNT:LI26:1:ALLKICKS.FLNK",16777215,1,"MGNT:LI26:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:LI26:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:LI26:1:SEXTSWITCH")
}

record(seq, "MGNT:LI26:1:SEXTSWITCH") {
  field(DOL1, "MGNT:LI26:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:LI26:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI26:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI26:1:SEXTCTRL")
}

record(seq, "MGNT:LI26:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:LI26:1:ALLSTAR")
  field(LNK1, "MGNT:LI26:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:LI26:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI26:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI26:1:SEXTCTRL",20,10,0,0,"MGNT:LI26:1:SEXTCTRL")
#! Field("MGNT:LI26:1:SEXTCTRL.FLNK",16777215,1,"MGNT:LI26:1:SEXTCTRL.FLNK")
#! Link("MGNT:LI26:1:SEXTCTRL.FLNK","MGNT:LI26:1:SEXTSWITCH")
#! Field("MGNT:LI26:1:SEXTCTRL.FFVL",16777215,1,"MGNT:LI26:1:SEXTCTRL.FFVL")
#! Record("MGNT:LI26:1:SEXTSWITCH",460,322,0,0,"MGNT:LI26:1:SEXTSWITCH")
#! Field("MGNT:LI26:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:LI26:1:SEXTSWITCH.DOL1")
#! Link("MGNT:LI26:1:SEXTSWITCH.DOL1","MGNT:LI26:1:SEXTCTRL.FFVL")
#! Field("MGNT:LI26:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:LI26:1:SEXTSWITCH.LNK1")
#! Field("MGNT:LI26:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:LI26:1:SEXTSWITCH.FLNK")
#! Record("MGNT:LI26:1:ALLSEXTSGO",240,96,0,0,"MGNT:LI26:1:ALLSEXTSGO")
#! Field("MGNT:LI26:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:LI26:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:LI26:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:LI26:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:LI26:1:ALLSEXTSGO.LNK1","MGNT:LI26:1:ALLSEXTS.VAL")
#! Record("MGNT:LI26:1:ALLSEXTS",540,102,0,0,"MGNT:LI26:1:ALLSEXTS")
#! Field("MGNT:LI26:1:ALLSEXTS.VAL",16777215,0,"MGNT:LI26:1:ALLSEXTS.VAL")
#! Field("MGNT:LI26:1:ALLSEXTS.FLNK",16777215,1,"MGNT:LI26:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record (seq, "MGNT:LI26:1:ALLBENDSSEL"){
}
record (seq, "MGNT:LI26:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:LI26:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:LI26:1:ALLKICKSSEL"){
}
record (seq, "MGNT:LI26:1:ALLSEXTSSEL"){
}

record (seq, "MGNT:LI26:1:ALLLGPSSSEL"){
  field (DOL1, "MGNT:LI26:1:ALLLGPSS")
  field (LNK1, "LGPS:LI26:2:SELECT CPP NMS")
}

record (seq, "MGNT:LI26:1:ALLQUADSSEL"){
  field (DOL1, "MGNT:LI26:1:ALLQUADS")
  field (DOL2, "MGNT:LI26:1:ALLQUADS")
  field (DOL3, "MGNT:LI26:1:ALLQUADS")
  field (DOL4, "MGNT:LI26:1:ALLQUADS")
  field (DOL5, "MGNT:LI26:1:ALLQUADS")
  field (DOL6, "MGNT:LI26:1:ALLQUADS")
  field (DOL7, "MGNT:LI26:1:ALLQUADS")
  field (DOL8, "MGNT:LI26:1:ALLQUADS")
  field (LNK1, "QUAD:LI26:201:SELECT CPP NMS")
  field (LNK2, "QUAD:LI26:301:SELECT CPP NMS")
  field (LNK3, "QUAD:LI26:401:SELECT CPP NMS")
  field (LNK4, "QUAD:LI26:501:SELECT CPP NMS")
  field (LNK5, "QUAD:LI26:601:SELECT CPP NMS")
  field (LNK6, "QUAD:LI26:701:SELECT CPP NMS")
  field (LNK7, "QUAD:LI26:801:SELECT CPP NMS")
  field (LNK8, "QUAD:LI26:901:SELECT CPP NMS")
}

record (seq, "MGNT:LI26:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:LI26:1:ALLXCORS")
  field (DOL2, "MGNT:LI26:1:ALLXCORS")
  field (DOL3, "MGNT:LI26:1:ALLXCORS")
  field (DOL4, "MGNT:LI26:1:ALLXCORS")
  field (DOL5, "MGNT:LI26:1:ALLXCORS")
  field (DOL6, "MGNT:LI26:1:ALLXCORS")
  field (DOL7, "MGNT:LI26:1:ALLXCORS")
  field (DOL8, "MGNT:LI26:1:ALLXCORS")
  field (LNK1, "XCOR:LI26:202:SELECT CPP NMS")
  field (LNK2, "XCOR:LI26:302:SELECT CPP NMS")
  field (LNK3, "XCOR:LI26:402:SELECT CPP NMS")
  field (LNK4, "XCOR:LI26:502:SELECT CPP NMS")
  field (LNK5, "XCOR:LI26:602:SELECT CPP NMS")
  field (LNK6, "XCOR:LI26:702:SELECT CPP NMS")
  field (LNK7, "XCOR:LI26:802:SELECT CPP NMS")
  field (LNK8, "XCOR:LI26:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI26:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:LI26:1:ALLYCORS")
  field (DOL2, "MGNT:LI26:1:ALLYCORS")
  field (DOL3, "MGNT:LI26:1:ALLYCORS")
  field (DOL4, "MGNT:LI26:1:ALLYCORS")
  field (DOL5, "MGNT:LI26:1:ALLYCORS")
  field (DOL6, "MGNT:LI26:1:ALLYCORS")
  field (DOL7, "MGNT:LI26:1:ALLYCORS")
  field (DOL8, "MGNT:LI26:1:ALLYCORS")
  field (LNK1, "YCOR:LI26:203:SELECT CPP NMS")
  field (LNK2, "YCOR:LI26:303:SELECT CPP NMS")
  field (LNK3, "YCOR:LI26:403:SELECT CPP NMS")
  field (LNK4, "YCOR:LI26:503:SELECT CPP NMS")
  field (LNK5, "YCOR:LI26:603:SELECT CPP NMS")
  field (LNK6, "YCOR:LI26:703:SELECT CPP NMS")
  field (LNK7, "YCOR:LI26:803:SELECT CPP NMS")
  field (LNK8, "YCOR:LI26:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI26:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (LNK1, "MGNT:LI26:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:LI26:1:QUADFUNCGO.PROC")
  field (LNK3, "MGNT:LI26:1:XCORFUNCGO.PROC")
  field (LNK4, "MGNT:LI26:1:YCORFUNCGO.PROC")
  field (LNK5, "MGNT:LI26:1:LGPSFUNCGO.PROC")
  field (LNK6, "MGNT:LI26:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:LI26:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI26:1:QUADFUNCGO") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI26:201:ALLFUNCGO")
  field (LNK2, "QUAD:LI26:301:ALLFUNCGO")
  field (LNK3, "QUAD:LI26:401:ALLFUNCGO")
  field (LNK4, "QUAD:LI26:501:ALLFUNCGO")
  field (LNK5, "QUAD:LI26:601:ALLFUNCGO")
  field (LNK6, "QUAD:LI26:701:ALLFUNCGO")
  field (FLNK, "MGNT:LI26:1:QUADFUNCGO1")
}

record (fanout, "MGNT:LI26:1:QUADFUNCGO1") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI26:801:ALLFUNCGO")
  field (LNK2, "QUAD:LI26:901:ALLFUNCGO")
  field (FLNK, "MGNT:LI26:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI26:1:XCORFUNCGO") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI26:202:ALLFUNCGO")
  field (LNK2, "XCOR:LI26:302:ALLFUNCGO")
  field (LNK3, "XCOR:LI26:402:ALLFUNCGO")
  field (LNK4, "XCOR:LI26:502:ALLFUNCGO")
  field (LNK5, "XCOR:LI26:602:ALLFUNCGO")
  field (LNK6, "XCOR:LI26:702:ALLFUNCGO")
  field (FLNK, "MGNT:LI26:1:XCORFUNCGO1")
}

record (fanout, "MGNT:LI26:1:XCORFUNCGO1") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI26:802:ALLFUNCGO")
  field (LNK2, "XCOR:LI26:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI26:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI26:1:YCORFUNCGO") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI26:203:ALLFUNCGO")
  field (LNK2, "YCOR:LI26:303:ALLFUNCGO")
  field (LNK3, "YCOR:LI26:403:ALLFUNCGO")
  field (LNK4, "YCOR:LI26:503:ALLFUNCGO")
  field (LNK5, "YCOR:LI26:603:ALLFUNCGO")
  field (LNK6, "YCOR:LI26:703:ALLFUNCGO")
  field (FLNK, "MGNT:LI26:1:YCORFUNCGO1")
}

record (fanout, "MGNT:LI26:1:YCORFUNCGO1") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI26:803:ALLFUNCGO")
  field (LNK2, "YCOR:LI26:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI26:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI26:1:LGPSFUNCGO"){
  field (DESC, "Process LGPS CTRL func")
  field (LNK1, "LGPS:LI26:2:ALLFUNCGO")
  field (FLNK, "MGNT:LI26:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI26:1:BENDFUNCGO"){
  field (DESC, "Process BEND CTRL func")
  field (FLNK, "MGNT:LI26:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI26:1:BTRMFUNCGO"){
  field (DESC, "Process BTRM CTRL func")
  field (FLNK, "MGNT:LI26:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI26:1:SOLNFUNCGO"){
  field (DESC, "Process SOLN CTRL func")
  field (FLNK, "MGNT:LI26:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI26:1:KICKFUNCGO"){
  field (DESC, "Process KICK CTRL func")
  field (FLNK, "MGNT:LI26:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI26:1:SEXTFUNCGO"){
  field (DESC, "Process SEXT CTRL func")
  field (FLNK, "MGNT:LI26:1:CTRLCLEAR")
}




#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LI26:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "LGPS:LI26:2:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LI26:2:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LI26:2:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LI26:2:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LI26:2:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LI26:2:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LI26:2:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LI26:2:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LI26:2:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LI26:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LI26:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LI26:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LI26:2:EDES.PROC PP")
    field(LNK2, "LGPS:LI26:2:EACT.PROC PP")
    field(LNK3, "LGPS:LI26:2:EERR.DISA PP")
    field(LNK4, "LGPS:LI26:2:ECON.PROC PP")
    field(LNK5, "LGPS:LI26:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:LI26:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:LI26:2:BLEM.PROC PP")
    field(LNK8, "LGPS:LI26:2:BMOD.PROC PP")
    field(LNK9, "LGPS:LI26:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LI26:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LI26:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LI26:2:BMAX")
  field(DOL2, "LGPS:LI26:2:BMAX")
  field(DOL3, "LGPS:LI26:2:BMAX")
  field(DOL4, "LGPS:LI26:2:BMIN")
  field(DOL5, "LGPS:LI26:2:BMIN")
  field(DOL6, "LGPS:LI26:2:BMIN")
  field(LNK1, "LGPS:LI26:2:BMAGX.HOPR")
  field(LNK2, "LGPS:LI26:2:BMAGY.HOPR")
  field(LNK3, "LGPS:LI26:2:BLEM.HOPR")
  field(LNK4, "LGPS:LI26:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LI26:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LI26:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LI26:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LI26:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LI26:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LI26:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LI26:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI26:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI26:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI26:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI26:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI26:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LI26:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LI26:2:EDES NPP MS")
  field(INPB, "LGPS:LI26:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI26:201:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI26:201:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI26:201:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI26:201:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI26:201:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI26:201:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI26:201:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI26:201:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI26:201:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI26:201:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI26:201:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI26:201:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI26:201:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI26:201:EDES.PROC PP")
    field(LNK2, "QUAD:LI26:201:EACT.PROC PP")
    field(LNK3, "QUAD:LI26:201:EERR.DISA PP")
    field(LNK4, "QUAD:LI26:201:ECON.PROC PP")
    field(LNK5, "QUAD:LI26:201:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI26:201:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI26:201:BLEM.PROC PP")
    field(LNK8, "QUAD:LI26:201:BMOD.PROC PP")
    field(LNK9, "QUAD:LI26:201:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI26:201:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI26:201:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI26:201:BMAX")
  field(DOL2, "QUAD:LI26:201:BMAX")
  field(DOL3, "QUAD:LI26:201:BMAX")
  field(DOL4, "QUAD:LI26:201:BMIN")
  field(DOL5, "QUAD:LI26:201:BMIN")
  field(DOL6, "QUAD:LI26:201:BMIN")
  field(LNK1, "QUAD:LI26:201:BMAGX.HOPR")
  field(LNK2, "QUAD:LI26:201:BMAGY.HOPR")
  field(LNK3, "QUAD:LI26:201:BLEM.HOPR")
  field(LNK4, "QUAD:LI26:201:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI26:201:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI26:201:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:201:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:201:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI26:201:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI26:201:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI26:201:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:201:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:201:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:201:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:201:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:201:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI26:201:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI26:201:EDES NPP MS")
  field(INPB, "QUAD:LI26:201:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI26:301:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI26:301:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI26:301:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI26:301:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI26:301:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI26:301:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI26:301:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI26:301:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI26:301:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI26:301:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI26:301:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI26:301:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI26:301:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI26:301:EDES.PROC PP")
    field(LNK2, "QUAD:LI26:301:EACT.PROC PP")
    field(LNK3, "QUAD:LI26:301:EERR.DISA PP")
    field(LNK4, "QUAD:LI26:301:ECON.PROC PP")
    field(LNK5, "QUAD:LI26:301:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI26:301:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI26:301:BLEM.PROC PP")
    field(LNK8, "QUAD:LI26:301:BMOD.PROC PP")
    field(LNK9, "QUAD:LI26:301:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI26:301:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI26:301:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI26:301:BMAX")
  field(DOL2, "QUAD:LI26:301:BMAX")
  field(DOL3, "QUAD:LI26:301:BMAX")
  field(DOL4, "QUAD:LI26:301:BMIN")
  field(DOL5, "QUAD:LI26:301:BMIN")
  field(DOL6, "QUAD:LI26:301:BMIN")
  field(LNK1, "QUAD:LI26:301:BMAGX.HOPR")
  field(LNK2, "QUAD:LI26:301:BMAGY.HOPR")
  field(LNK3, "QUAD:LI26:301:BLEM.HOPR")
  field(LNK4, "QUAD:LI26:301:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI26:301:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI26:301:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:301:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:301:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI26:301:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI26:301:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI26:301:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:301:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:301:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:301:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:301:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:301:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI26:301:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI26:301:EDES NPP MS")
  field(INPB, "QUAD:LI26:301:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI26:401:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI26:401:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI26:401:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI26:401:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI26:401:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI26:401:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI26:401:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI26:401:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI26:401:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI26:401:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI26:401:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI26:401:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI26:401:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI26:401:EDES.PROC PP")
    field(LNK2, "QUAD:LI26:401:EACT.PROC PP")
    field(LNK3, "QUAD:LI26:401:EERR.DISA PP")
    field(LNK4, "QUAD:LI26:401:ECON.PROC PP")
    field(LNK5, "QUAD:LI26:401:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI26:401:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI26:401:BLEM.PROC PP")
    field(LNK8, "QUAD:LI26:401:BMOD.PROC PP")
    field(LNK9, "QUAD:LI26:401:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI26:401:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI26:401:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI26:401:BMAX")
  field(DOL2, "QUAD:LI26:401:BMAX")
  field(DOL3, "QUAD:LI26:401:BMAX")
  field(DOL4, "QUAD:LI26:401:BMIN")
  field(DOL5, "QUAD:LI26:401:BMIN")
  field(DOL6, "QUAD:LI26:401:BMIN")
  field(LNK1, "QUAD:LI26:401:BMAGX.HOPR")
  field(LNK2, "QUAD:LI26:401:BMAGY.HOPR")
  field(LNK3, "QUAD:LI26:401:BLEM.HOPR")
  field(LNK4, "QUAD:LI26:401:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI26:401:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI26:401:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:401:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:401:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI26:401:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI26:401:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI26:401:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:401:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:401:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:401:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:401:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:401:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI26:401:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI26:401:EDES NPP MS")
  field(INPB, "QUAD:LI26:401:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI26:501:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI26:501:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI26:501:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI26:501:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI26:501:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI26:501:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI26:501:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI26:501:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI26:501:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI26:501:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI26:501:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI26:501:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI26:501:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI26:501:EDES.PROC PP")
    field(LNK2, "QUAD:LI26:501:EACT.PROC PP")
    field(LNK3, "QUAD:LI26:501:EERR.DISA PP")
    field(LNK4, "QUAD:LI26:501:ECON.PROC PP")
    field(LNK5, "QUAD:LI26:501:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI26:501:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI26:501:BLEM.PROC PP")
    field(LNK8, "QUAD:LI26:501:BMOD.PROC PP")
    field(LNK9, "QUAD:LI26:501:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI26:501:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI26:501:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI26:501:BMAX")
  field(DOL2, "QUAD:LI26:501:BMAX")
  field(DOL3, "QUAD:LI26:501:BMAX")
  field(DOL4, "QUAD:LI26:501:BMIN")
  field(DOL5, "QUAD:LI26:501:BMIN")
  field(DOL6, "QUAD:LI26:501:BMIN")
  field(LNK1, "QUAD:LI26:501:BMAGX.HOPR")
  field(LNK2, "QUAD:LI26:501:BMAGY.HOPR")
  field(LNK3, "QUAD:LI26:501:BLEM.HOPR")
  field(LNK4, "QUAD:LI26:501:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI26:501:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI26:501:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:501:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:501:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI26:501:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI26:501:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI26:501:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:501:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:501:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:501:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:501:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:501:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI26:501:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI26:501:EDES NPP MS")
  field(INPB, "QUAD:LI26:501:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI26:601:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI26:601:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI26:601:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI26:601:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI26:601:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI26:601:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI26:601:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI26:601:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI26:601:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI26:601:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI26:601:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI26:601:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI26:601:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI26:601:EDES.PROC PP")
    field(LNK2, "QUAD:LI26:601:EACT.PROC PP")
    field(LNK3, "QUAD:LI26:601:EERR.DISA PP")
    field(LNK4, "QUAD:LI26:601:ECON.PROC PP")
    field(LNK5, "QUAD:LI26:601:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI26:601:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI26:601:BLEM.PROC PP")
    field(LNK8, "QUAD:LI26:601:BMOD.PROC PP")
    field(LNK9, "QUAD:LI26:601:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI26:601:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI26:601:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI26:601:BMAX")
  field(DOL2, "QUAD:LI26:601:BMAX")
  field(DOL3, "QUAD:LI26:601:BMAX")
  field(DOL4, "QUAD:LI26:601:BMIN")
  field(DOL5, "QUAD:LI26:601:BMIN")
  field(DOL6, "QUAD:LI26:601:BMIN")
  field(LNK1, "QUAD:LI26:601:BMAGX.HOPR")
  field(LNK2, "QUAD:LI26:601:BMAGY.HOPR")
  field(LNK3, "QUAD:LI26:601:BLEM.HOPR")
  field(LNK4, "QUAD:LI26:601:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI26:601:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI26:601:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:601:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:601:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI26:601:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI26:601:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI26:601:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:601:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:601:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:601:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:601:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:601:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI26:601:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI26:601:EDES NPP MS")
  field(INPB, "QUAD:LI26:601:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI26:701:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI26:701:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI26:701:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI26:701:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI26:701:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI26:701:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI26:701:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI26:701:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI26:701:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI26:701:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI26:701:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI26:701:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI26:701:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI26:701:EDES.PROC PP")
    field(LNK2, "QUAD:LI26:701:EACT.PROC PP")
    field(LNK3, "QUAD:LI26:701:EERR.DISA PP")
    field(LNK4, "QUAD:LI26:701:ECON.PROC PP")
    field(LNK5, "QUAD:LI26:701:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI26:701:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI26:701:BLEM.PROC PP")
    field(LNK8, "QUAD:LI26:701:BMOD.PROC PP")
    field(LNK9, "QUAD:LI26:701:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI26:701:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI26:701:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI26:701:BMAX")
  field(DOL2, "QUAD:LI26:701:BMAX")
  field(DOL3, "QUAD:LI26:701:BMAX")
  field(DOL4, "QUAD:LI26:701:BMIN")
  field(DOL5, "QUAD:LI26:701:BMIN")
  field(DOL6, "QUAD:LI26:701:BMIN")
  field(LNK1, "QUAD:LI26:701:BMAGX.HOPR")
  field(LNK2, "QUAD:LI26:701:BMAGY.HOPR")
  field(LNK3, "QUAD:LI26:701:BLEM.HOPR")
  field(LNK4, "QUAD:LI26:701:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI26:701:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI26:701:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:701:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:701:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI26:701:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI26:701:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI26:701:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:701:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:701:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:701:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:701:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:701:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI26:701:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI26:701:EDES NPP MS")
  field(INPB, "QUAD:LI26:701:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI26:801:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI26:801:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI26:801:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI26:801:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI26:801:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI26:801:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI26:801:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI26:801:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI26:801:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI26:801:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI26:801:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI26:801:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI26:801:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI26:801:EDES.PROC PP")
    field(LNK2, "QUAD:LI26:801:EACT.PROC PP")
    field(LNK3, "QUAD:LI26:801:EERR.DISA PP")
    field(LNK4, "QUAD:LI26:801:ECON.PROC PP")
    field(LNK5, "QUAD:LI26:801:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI26:801:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI26:801:BLEM.PROC PP")
    field(LNK8, "QUAD:LI26:801:BMOD.PROC PP")
    field(LNK9, "QUAD:LI26:801:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI26:801:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI26:801:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI26:801:BMAX")
  field(DOL2, "QUAD:LI26:801:BMAX")
  field(DOL3, "QUAD:LI26:801:BMAX")
  field(DOL4, "QUAD:LI26:801:BMIN")
  field(DOL5, "QUAD:LI26:801:BMIN")
  field(DOL6, "QUAD:LI26:801:BMIN")
  field(LNK1, "QUAD:LI26:801:BMAGX.HOPR")
  field(LNK2, "QUAD:LI26:801:BMAGY.HOPR")
  field(LNK3, "QUAD:LI26:801:BLEM.HOPR")
  field(LNK4, "QUAD:LI26:801:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI26:801:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI26:801:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:801:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:801:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI26:801:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI26:801:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI26:801:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:801:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:801:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:801:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:801:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:801:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI26:801:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI26:801:EDES NPP MS")
  field(INPB, "QUAD:LI26:801:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI26:901:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI26:901:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI26:901:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI26:901:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI26:901:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI26:901:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI26:901:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI26:901:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI26:901:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI26:901:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI26:901:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI26:901:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI26:901:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI26:901:EDES.PROC PP")
    field(LNK2, "QUAD:LI26:901:EACT.PROC PP")
    field(LNK3, "QUAD:LI26:901:EERR.DISA PP")
    field(LNK4, "QUAD:LI26:901:ECON.PROC PP")
    field(LNK5, "QUAD:LI26:901:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI26:901:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI26:901:BLEM.PROC PP")
    field(LNK8, "QUAD:LI26:901:BMOD.PROC PP")
    field(LNK9, "QUAD:LI26:901:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI26:901:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI26:901:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI26:901:BMAX")
  field(DOL2, "QUAD:LI26:901:BMAX")
  field(DOL3, "QUAD:LI26:901:BMAX")
  field(DOL4, "QUAD:LI26:901:BMIN")
  field(DOL5, "QUAD:LI26:901:BMIN")
  field(DOL6, "QUAD:LI26:901:BMIN")
  field(LNK1, "QUAD:LI26:901:BMAGX.HOPR")
  field(LNK2, "QUAD:LI26:901:BMAGY.HOPR")
  field(LNK3, "QUAD:LI26:901:BLEM.HOPR")
  field(LNK4, "QUAD:LI26:901:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI26:901:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI26:901:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:901:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI26:901:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI26:901:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI26:901:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI26:901:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:901:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:901:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:901:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI26:901:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI26:901:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI26:901:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI26:901:EDES NPP MS")
  field(INPB, "QUAD:LI26:901:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI26:202:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI26:202:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI26:202:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI26:202:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI26:202:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI26:202:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI26:202:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI26:202:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI26:202:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI26:202:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI26:202:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI26:202:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI26:202:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI26:202:EDES.PROC PP")
    field(LNK2, "XCOR:LI26:202:EACT.PROC PP")
    field(LNK3, "XCOR:LI26:202:EERR.DISA PP")
    field(LNK4, "XCOR:LI26:202:ECON.PROC PP")
    field(LNK5, "XCOR:LI26:202:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI26:202:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI26:202:BLEM.PROC PP")
    field(LNK8, "XCOR:LI26:202:BMOD.PROC PP")
    field(LNK9, "XCOR:LI26:202:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI26:202:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI26:202:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI26:202:BMAX")
  field(DOL2, "XCOR:LI26:202:BMAX")
  field(DOL3, "XCOR:LI26:202:BMAX")
  field(DOL4, "XCOR:LI26:202:BMIN")
  field(DOL5, "XCOR:LI26:202:BMIN")
  field(DOL6, "XCOR:LI26:202:BMIN")
  field(LNK1, "XCOR:LI26:202:BMAGX.HOPR")
  field(LNK2, "XCOR:LI26:202:BMAGY.HOPR")
  field(LNK3, "XCOR:LI26:202:BLEM.HOPR")
  field(LNK4, "XCOR:LI26:202:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI26:202:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI26:202:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:202:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:202:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI26:202:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI26:202:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI26:202:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:202:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:202:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:202:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:202:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:202:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI26:202:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI26:202:EDES NPP MS")
  field(INPB, "XCOR:LI26:202:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI26:302:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI26:302:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI26:302:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI26:302:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI26:302:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI26:302:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI26:302:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI26:302:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI26:302:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI26:302:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI26:302:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI26:302:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI26:302:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI26:302:EDES.PROC PP")
    field(LNK2, "XCOR:LI26:302:EACT.PROC PP")
    field(LNK3, "XCOR:LI26:302:EERR.DISA PP")
    field(LNK4, "XCOR:LI26:302:ECON.PROC PP")
    field(LNK5, "XCOR:LI26:302:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI26:302:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI26:302:BLEM.PROC PP")
    field(LNK8, "XCOR:LI26:302:BMOD.PROC PP")
    field(LNK9, "XCOR:LI26:302:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI26:302:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI26:302:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI26:302:BMAX")
  field(DOL2, "XCOR:LI26:302:BMAX")
  field(DOL3, "XCOR:LI26:302:BMAX")
  field(DOL4, "XCOR:LI26:302:BMIN")
  field(DOL5, "XCOR:LI26:302:BMIN")
  field(DOL6, "XCOR:LI26:302:BMIN")
  field(LNK1, "XCOR:LI26:302:BMAGX.HOPR")
  field(LNK2, "XCOR:LI26:302:BMAGY.HOPR")
  field(LNK3, "XCOR:LI26:302:BLEM.HOPR")
  field(LNK4, "XCOR:LI26:302:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI26:302:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI26:302:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:302:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:302:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI26:302:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI26:302:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI26:302:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:302:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:302:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:302:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:302:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:302:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI26:302:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI26:302:EDES NPP MS")
  field(INPB, "XCOR:LI26:302:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI26:402:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI26:402:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI26:402:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI26:402:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI26:402:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI26:402:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI26:402:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI26:402:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI26:402:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI26:402:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI26:402:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI26:402:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI26:402:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI26:402:EDES.PROC PP")
    field(LNK2, "XCOR:LI26:402:EACT.PROC PP")
    field(LNK3, "XCOR:LI26:402:EERR.DISA PP")
    field(LNK4, "XCOR:LI26:402:ECON.PROC PP")
    field(LNK5, "XCOR:LI26:402:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI26:402:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI26:402:BLEM.PROC PP")
    field(LNK8, "XCOR:LI26:402:BMOD.PROC PP")
    field(LNK9, "XCOR:LI26:402:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI26:402:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI26:402:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI26:402:BMAX")
  field(DOL2, "XCOR:LI26:402:BMAX")
  field(DOL3, "XCOR:LI26:402:BMAX")
  field(DOL4, "XCOR:LI26:402:BMIN")
  field(DOL5, "XCOR:LI26:402:BMIN")
  field(DOL6, "XCOR:LI26:402:BMIN")
  field(LNK1, "XCOR:LI26:402:BMAGX.HOPR")
  field(LNK2, "XCOR:LI26:402:BMAGY.HOPR")
  field(LNK3, "XCOR:LI26:402:BLEM.HOPR")
  field(LNK4, "XCOR:LI26:402:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI26:402:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI26:402:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:402:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:402:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI26:402:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI26:402:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI26:402:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:402:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:402:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:402:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:402:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:402:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI26:402:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI26:402:EDES NPP MS")
  field(INPB, "XCOR:LI26:402:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI26:502:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI26:502:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI26:502:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI26:502:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI26:502:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI26:502:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI26:502:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI26:502:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI26:502:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI26:502:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI26:502:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI26:502:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI26:502:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI26:502:EDES.PROC PP")
    field(LNK2, "XCOR:LI26:502:EACT.PROC PP")
    field(LNK3, "XCOR:LI26:502:EERR.DISA PP")
    field(LNK4, "XCOR:LI26:502:ECON.PROC PP")
    field(LNK5, "XCOR:LI26:502:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI26:502:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI26:502:BLEM.PROC PP")
    field(LNK8, "XCOR:LI26:502:BMOD.PROC PP")
    field(LNK9, "XCOR:LI26:502:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI26:502:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI26:502:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI26:502:BMAX")
  field(DOL2, "XCOR:LI26:502:BMAX")
  field(DOL3, "XCOR:LI26:502:BMAX")
  field(DOL4, "XCOR:LI26:502:BMIN")
  field(DOL5, "XCOR:LI26:502:BMIN")
  field(DOL6, "XCOR:LI26:502:BMIN")
  field(LNK1, "XCOR:LI26:502:BMAGX.HOPR")
  field(LNK2, "XCOR:LI26:502:BMAGY.HOPR")
  field(LNK3, "XCOR:LI26:502:BLEM.HOPR")
  field(LNK4, "XCOR:LI26:502:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI26:502:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI26:502:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:502:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:502:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI26:502:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI26:502:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI26:502:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:502:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:502:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:502:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:502:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:502:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI26:502:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI26:502:EDES NPP MS")
  field(INPB, "XCOR:LI26:502:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI26:602:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI26:602:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI26:602:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI26:602:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI26:602:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI26:602:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI26:602:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI26:602:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI26:602:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI26:602:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI26:602:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI26:602:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI26:602:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI26:602:EDES.PROC PP")
    field(LNK2, "XCOR:LI26:602:EACT.PROC PP")
    field(LNK3, "XCOR:LI26:602:EERR.DISA PP")
    field(LNK4, "XCOR:LI26:602:ECON.PROC PP")
    field(LNK5, "XCOR:LI26:602:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI26:602:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI26:602:BLEM.PROC PP")
    field(LNK8, "XCOR:LI26:602:BMOD.PROC PP")
    field(LNK9, "XCOR:LI26:602:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI26:602:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI26:602:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI26:602:BMAX")
  field(DOL2, "XCOR:LI26:602:BMAX")
  field(DOL3, "XCOR:LI26:602:BMAX")
  field(DOL4, "XCOR:LI26:602:BMIN")
  field(DOL5, "XCOR:LI26:602:BMIN")
  field(DOL6, "XCOR:LI26:602:BMIN")
  field(LNK1, "XCOR:LI26:602:BMAGX.HOPR")
  field(LNK2, "XCOR:LI26:602:BMAGY.HOPR")
  field(LNK3, "XCOR:LI26:602:BLEM.HOPR")
  field(LNK4, "XCOR:LI26:602:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI26:602:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI26:602:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:602:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:602:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI26:602:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI26:602:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI26:602:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:602:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:602:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:602:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:602:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:602:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI26:602:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI26:602:EDES NPP MS")
  field(INPB, "XCOR:LI26:602:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI26:702:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI26:702:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI26:702:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI26:702:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI26:702:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI26:702:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI26:702:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI26:702:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI26:702:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI26:702:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI26:702:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI26:702:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI26:702:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI26:702:EDES.PROC PP")
    field(LNK2, "XCOR:LI26:702:EACT.PROC PP")
    field(LNK3, "XCOR:LI26:702:EERR.DISA PP")
    field(LNK4, "XCOR:LI26:702:ECON.PROC PP")
    field(LNK5, "XCOR:LI26:702:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI26:702:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI26:702:BLEM.PROC PP")
    field(LNK8, "XCOR:LI26:702:BMOD.PROC PP")
    field(LNK9, "XCOR:LI26:702:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI26:702:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI26:702:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI26:702:BMAX")
  field(DOL2, "XCOR:LI26:702:BMAX")
  field(DOL3, "XCOR:LI26:702:BMAX")
  field(DOL4, "XCOR:LI26:702:BMIN")
  field(DOL5, "XCOR:LI26:702:BMIN")
  field(DOL6, "XCOR:LI26:702:BMIN")
  field(LNK1, "XCOR:LI26:702:BMAGX.HOPR")
  field(LNK2, "XCOR:LI26:702:BMAGY.HOPR")
  field(LNK3, "XCOR:LI26:702:BLEM.HOPR")
  field(LNK4, "XCOR:LI26:702:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI26:702:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI26:702:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:702:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:702:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI26:702:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI26:702:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI26:702:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:702:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:702:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:702:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:702:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:702:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI26:702:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI26:702:EDES NPP MS")
  field(INPB, "XCOR:LI26:702:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI26:802:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI26:802:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI26:802:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI26:802:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI26:802:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI26:802:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI26:802:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI26:802:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI26:802:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI26:802:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI26:802:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI26:802:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI26:802:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI26:802:EDES.PROC PP")
    field(LNK2, "XCOR:LI26:802:EACT.PROC PP")
    field(LNK3, "XCOR:LI26:802:EERR.DISA PP")
    field(LNK4, "XCOR:LI26:802:ECON.PROC PP")
    field(LNK5, "XCOR:LI26:802:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI26:802:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI26:802:BLEM.PROC PP")
    field(LNK8, "XCOR:LI26:802:BMOD.PROC PP")
    field(LNK9, "XCOR:LI26:802:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI26:802:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI26:802:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI26:802:BMAX")
  field(DOL2, "XCOR:LI26:802:BMAX")
  field(DOL3, "XCOR:LI26:802:BMAX")
  field(DOL4, "XCOR:LI26:802:BMIN")
  field(DOL5, "XCOR:LI26:802:BMIN")
  field(DOL6, "XCOR:LI26:802:BMIN")
  field(LNK1, "XCOR:LI26:802:BMAGX.HOPR")
  field(LNK2, "XCOR:LI26:802:BMAGY.HOPR")
  field(LNK3, "XCOR:LI26:802:BLEM.HOPR")
  field(LNK4, "XCOR:LI26:802:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI26:802:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI26:802:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:802:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:802:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI26:802:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI26:802:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI26:802:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:802:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:802:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:802:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:802:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:802:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI26:802:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI26:802:EDES NPP MS")
  field(INPB, "XCOR:LI26:802:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI26:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI26:900:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI26:900:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI26:900:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI26:900:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI26:900:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI26:900:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI26:900:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI26:900:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI26:900:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI26:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI26:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI26:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI26:900:EDES.PROC PP")
    field(LNK2, "XCOR:LI26:900:EACT.PROC PP")
    field(LNK3, "XCOR:LI26:900:EERR.DISA PP")
    field(LNK4, "XCOR:LI26:900:ECON.PROC PP")
    field(LNK5, "XCOR:LI26:900:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI26:900:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI26:900:BLEM.PROC PP")
    field(LNK8, "XCOR:LI26:900:BMOD.PROC PP")
    field(LNK9, "XCOR:LI26:900:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI26:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI26:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI26:900:BMAX")
  field(DOL2, "XCOR:LI26:900:BMAX")
  field(DOL3, "XCOR:LI26:900:BMAX")
  field(DOL4, "XCOR:LI26:900:BMIN")
  field(DOL5, "XCOR:LI26:900:BMIN")
  field(DOL6, "XCOR:LI26:900:BMIN")
  field(LNK1, "XCOR:LI26:900:BMAGX.HOPR")
  field(LNK2, "XCOR:LI26:900:BMAGY.HOPR")
  field(LNK3, "XCOR:LI26:900:BLEM.HOPR")
  field(LNK4, "XCOR:LI26:900:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI26:900:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI26:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI26:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI26:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI26:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI26:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI26:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI26:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI26:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI26:900:EDES NPP MS")
  field(INPB, "XCOR:LI26:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI26:203:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI26:203:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI26:203:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI26:203:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI26:203:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI26:203:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI26:203:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI26:203:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI26:203:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI26:203:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI26:203:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI26:203:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI26:203:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI26:203:EDES.PROC PP")
    field(LNK2, "YCOR:LI26:203:EACT.PROC PP")
    field(LNK3, "YCOR:LI26:203:EERR.DISA PP")
    field(LNK4, "YCOR:LI26:203:ECON.PROC PP")
    field(LNK5, "YCOR:LI26:203:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI26:203:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI26:203:BLEM.PROC PP")
    field(LNK8, "YCOR:LI26:203:BMOD.PROC PP")
    field(LNK9, "YCOR:LI26:203:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI26:203:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI26:203:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI26:203:BMAX")
  field(DOL2, "YCOR:LI26:203:BMAX")
  field(DOL3, "YCOR:LI26:203:BMAX")
  field(DOL4, "YCOR:LI26:203:BMIN")
  field(DOL5, "YCOR:LI26:203:BMIN")
  field(DOL6, "YCOR:LI26:203:BMIN")
  field(LNK1, "YCOR:LI26:203:BMAGX.HOPR")
  field(LNK2, "YCOR:LI26:203:BMAGY.HOPR")
  field(LNK3, "YCOR:LI26:203:BLEM.HOPR")
  field(LNK4, "YCOR:LI26:203:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI26:203:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI26:203:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:203:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:203:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI26:203:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI26:203:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI26:203:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:203:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:203:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:203:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:203:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:203:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI26:203:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI26:203:EDES NPP MS")
  field(INPB, "YCOR:LI26:203:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI26:303:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI26:303:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI26:303:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI26:303:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI26:303:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI26:303:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI26:303:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI26:303:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI26:303:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI26:303:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI26:303:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI26:303:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI26:303:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI26:303:EDES.PROC PP")
    field(LNK2, "YCOR:LI26:303:EACT.PROC PP")
    field(LNK3, "YCOR:LI26:303:EERR.DISA PP")
    field(LNK4, "YCOR:LI26:303:ECON.PROC PP")
    field(LNK5, "YCOR:LI26:303:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI26:303:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI26:303:BLEM.PROC PP")
    field(LNK8, "YCOR:LI26:303:BMOD.PROC PP")
    field(LNK9, "YCOR:LI26:303:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI26:303:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI26:303:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI26:303:BMAX")
  field(DOL2, "YCOR:LI26:303:BMAX")
  field(DOL3, "YCOR:LI26:303:BMAX")
  field(DOL4, "YCOR:LI26:303:BMIN")
  field(DOL5, "YCOR:LI26:303:BMIN")
  field(DOL6, "YCOR:LI26:303:BMIN")
  field(LNK1, "YCOR:LI26:303:BMAGX.HOPR")
  field(LNK2, "YCOR:LI26:303:BMAGY.HOPR")
  field(LNK3, "YCOR:LI26:303:BLEM.HOPR")
  field(LNK4, "YCOR:LI26:303:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI26:303:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI26:303:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:303:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:303:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI26:303:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI26:303:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI26:303:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:303:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:303:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:303:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:303:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:303:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI26:303:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI26:303:EDES NPP MS")
  field(INPB, "YCOR:LI26:303:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI26:403:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI26:403:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI26:403:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI26:403:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI26:403:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI26:403:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI26:403:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI26:403:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI26:403:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI26:403:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI26:403:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI26:403:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI26:403:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI26:403:EDES.PROC PP")
    field(LNK2, "YCOR:LI26:403:EACT.PROC PP")
    field(LNK3, "YCOR:LI26:403:EERR.DISA PP")
    field(LNK4, "YCOR:LI26:403:ECON.PROC PP")
    field(LNK5, "YCOR:LI26:403:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI26:403:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI26:403:BLEM.PROC PP")
    field(LNK8, "YCOR:LI26:403:BMOD.PROC PP")
    field(LNK9, "YCOR:LI26:403:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI26:403:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI26:403:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI26:403:BMAX")
  field(DOL2, "YCOR:LI26:403:BMAX")
  field(DOL3, "YCOR:LI26:403:BMAX")
  field(DOL4, "YCOR:LI26:403:BMIN")
  field(DOL5, "YCOR:LI26:403:BMIN")
  field(DOL6, "YCOR:LI26:403:BMIN")
  field(LNK1, "YCOR:LI26:403:BMAGX.HOPR")
  field(LNK2, "YCOR:LI26:403:BMAGY.HOPR")
  field(LNK3, "YCOR:LI26:403:BLEM.HOPR")
  field(LNK4, "YCOR:LI26:403:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI26:403:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI26:403:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:403:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:403:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI26:403:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI26:403:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI26:403:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:403:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:403:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:403:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:403:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:403:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI26:403:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI26:403:EDES NPP MS")
  field(INPB, "YCOR:LI26:403:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI26:503:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI26:503:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI26:503:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI26:503:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI26:503:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI26:503:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI26:503:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI26:503:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI26:503:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI26:503:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI26:503:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI26:503:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI26:503:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI26:503:EDES.PROC PP")
    field(LNK2, "YCOR:LI26:503:EACT.PROC PP")
    field(LNK3, "YCOR:LI26:503:EERR.DISA PP")
    field(LNK4, "YCOR:LI26:503:ECON.PROC PP")
    field(LNK5, "YCOR:LI26:503:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI26:503:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI26:503:BLEM.PROC PP")
    field(LNK8, "YCOR:LI26:503:BMOD.PROC PP")
    field(LNK9, "YCOR:LI26:503:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI26:503:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI26:503:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI26:503:BMAX")
  field(DOL2, "YCOR:LI26:503:BMAX")
  field(DOL3, "YCOR:LI26:503:BMAX")
  field(DOL4, "YCOR:LI26:503:BMIN")
  field(DOL5, "YCOR:LI26:503:BMIN")
  field(DOL6, "YCOR:LI26:503:BMIN")
  field(LNK1, "YCOR:LI26:503:BMAGX.HOPR")
  field(LNK2, "YCOR:LI26:503:BMAGY.HOPR")
  field(LNK3, "YCOR:LI26:503:BLEM.HOPR")
  field(LNK4, "YCOR:LI26:503:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI26:503:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI26:503:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:503:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:503:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI26:503:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI26:503:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI26:503:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:503:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:503:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:503:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:503:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:503:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI26:503:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI26:503:EDES NPP MS")
  field(INPB, "YCOR:LI26:503:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI26:603:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI26:603:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI26:603:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI26:603:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI26:603:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI26:603:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI26:603:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI26:603:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI26:603:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI26:603:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI26:603:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI26:603:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI26:603:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI26:603:EDES.PROC PP")
    field(LNK2, "YCOR:LI26:603:EACT.PROC PP")
    field(LNK3, "YCOR:LI26:603:EERR.DISA PP")
    field(LNK4, "YCOR:LI26:603:ECON.PROC PP")
    field(LNK5, "YCOR:LI26:603:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI26:603:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI26:603:BLEM.PROC PP")
    field(LNK8, "YCOR:LI26:603:BMOD.PROC PP")
    field(LNK9, "YCOR:LI26:603:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI26:603:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI26:603:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI26:603:BMAX")
  field(DOL2, "YCOR:LI26:603:BMAX")
  field(DOL3, "YCOR:LI26:603:BMAX")
  field(DOL4, "YCOR:LI26:603:BMIN")
  field(DOL5, "YCOR:LI26:603:BMIN")
  field(DOL6, "YCOR:LI26:603:BMIN")
  field(LNK1, "YCOR:LI26:603:BMAGX.HOPR")
  field(LNK2, "YCOR:LI26:603:BMAGY.HOPR")
  field(LNK3, "YCOR:LI26:603:BLEM.HOPR")
  field(LNK4, "YCOR:LI26:603:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI26:603:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI26:603:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:603:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:603:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI26:603:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI26:603:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI26:603:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:603:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:603:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:603:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:603:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:603:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI26:603:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI26:603:EDES NPP MS")
  field(INPB, "YCOR:LI26:603:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI26:703:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI26:703:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI26:703:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI26:703:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI26:703:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI26:703:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI26:703:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI26:703:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI26:703:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI26:703:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI26:703:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI26:703:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI26:703:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI26:703:EDES.PROC PP")
    field(LNK2, "YCOR:LI26:703:EACT.PROC PP")
    field(LNK3, "YCOR:LI26:703:EERR.DISA PP")
    field(LNK4, "YCOR:LI26:703:ECON.PROC PP")
    field(LNK5, "YCOR:LI26:703:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI26:703:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI26:703:BLEM.PROC PP")
    field(LNK8, "YCOR:LI26:703:BMOD.PROC PP")
    field(LNK9, "YCOR:LI26:703:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI26:703:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI26:703:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI26:703:BMAX")
  field(DOL2, "YCOR:LI26:703:BMAX")
  field(DOL3, "YCOR:LI26:703:BMAX")
  field(DOL4, "YCOR:LI26:703:BMIN")
  field(DOL5, "YCOR:LI26:703:BMIN")
  field(DOL6, "YCOR:LI26:703:BMIN")
  field(LNK1, "YCOR:LI26:703:BMAGX.HOPR")
  field(LNK2, "YCOR:LI26:703:BMAGY.HOPR")
  field(LNK3, "YCOR:LI26:703:BLEM.HOPR")
  field(LNK4, "YCOR:LI26:703:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI26:703:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI26:703:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:703:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:703:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI26:703:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI26:703:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI26:703:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:703:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:703:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:703:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:703:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:703:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI26:703:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI26:703:EDES NPP MS")
  field(INPB, "YCOR:LI26:703:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI26:803:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI26:803:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI26:803:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI26:803:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI26:803:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI26:803:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI26:803:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI26:803:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI26:803:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI26:803:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI26:803:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI26:803:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI26:803:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI26:803:EDES.PROC PP")
    field(LNK2, "YCOR:LI26:803:EACT.PROC PP")
    field(LNK3, "YCOR:LI26:803:EERR.DISA PP")
    field(LNK4, "YCOR:LI26:803:ECON.PROC PP")
    field(LNK5, "YCOR:LI26:803:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI26:803:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI26:803:BLEM.PROC PP")
    field(LNK8, "YCOR:LI26:803:BMOD.PROC PP")
    field(LNK9, "YCOR:LI26:803:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI26:803:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI26:803:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI26:803:BMAX")
  field(DOL2, "YCOR:LI26:803:BMAX")
  field(DOL3, "YCOR:LI26:803:BMAX")
  field(DOL4, "YCOR:LI26:803:BMIN")
  field(DOL5, "YCOR:LI26:803:BMIN")
  field(DOL6, "YCOR:LI26:803:BMIN")
  field(LNK1, "YCOR:LI26:803:BMAGX.HOPR")
  field(LNK2, "YCOR:LI26:803:BMAGY.HOPR")
  field(LNK3, "YCOR:LI26:803:BLEM.HOPR")
  field(LNK4, "YCOR:LI26:803:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI26:803:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI26:803:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:803:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:803:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI26:803:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI26:803:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI26:803:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:803:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:803:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:803:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:803:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:803:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI26:803:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI26:803:EDES NPP MS")
  field(INPB, "YCOR:LI26:803:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI26:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI26:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI26:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI26:900:FUNC CA PP")
  field(DOL2, "MGNT:LI26:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI26:900:FUNC CA PP")
  field(DOL3, "MGNT:LI26:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI26:900:FUNC CA PP")
  field(DOL4, "MGNT:LI26:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI26:900:FUNC CA PP")
  field(DOL5, "MGNT:LI26:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI26:900:FUNC CA PP")
  field(DOL6, "MGNT:LI26:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI26:900:FUNC CA PP")
  field(DOL7, "MGNT:LI26:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI26:900:FUNC CA PP")
  field(DOL8, "MGNT:LI26:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI26:900:FUNC CA PP")
  field(DOL9, "MGNT:LI26:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI26:900:FUNC CA PP")
  field(DOLA, "MGNT:LI26:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI26:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI26:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI26:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI26:900:EDES.PROC PP")
    field(LNK2, "YCOR:LI26:900:EACT.PROC PP")
    field(LNK3, "YCOR:LI26:900:EERR.DISA PP")
    field(LNK4, "YCOR:LI26:900:ECON.PROC PP")
    field(LNK5, "YCOR:LI26:900:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI26:900:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI26:900:BLEM.PROC PP")
    field(LNK8, "YCOR:LI26:900:BMOD.PROC PP")
    field(LNK9, "YCOR:LI26:900:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI26:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI26:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI26:900:BMAX")
  field(DOL2, "YCOR:LI26:900:BMAX")
  field(DOL3, "YCOR:LI26:900:BMAX")
  field(DOL4, "YCOR:LI26:900:BMIN")
  field(DOL5, "YCOR:LI26:900:BMIN")
  field(DOL6, "YCOR:LI26:900:BMIN")
  field(LNK1, "YCOR:LI26:900:BMAGX.HOPR")
  field(LNK2, "YCOR:LI26:900:BMAGY.HOPR")
  field(LNK3, "YCOR:LI26:900:BLEM.HOPR")
  field(LNK4, "YCOR:LI26:900:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI26:900:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI26:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI26:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI26:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI26:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI26:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI26:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI26:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI26:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI26:900:EDES NPP MS")
  field(INPB, "YCOR:LI26:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:LI27:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:LI27:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:LI27:1:CTRL CA PP")
  field(LNK2, "MGNT:LI27:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:LI27:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:LI27:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:LI27:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:LI27:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:LI27:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:LI27:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:LI27:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:LI27:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:LI27:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:LI27:1:ALLSWITCH")
}

record(seq, "MGNT:LI27:1:ALLSWITCH") {
  field(DOL1, "MGNT:LI27:1:CTRL.FFVL")
  field(LNK1, "MGNT:LI27:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI27:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI27:1:CTRL")
}

record(bo, "MGNT:LI27:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:LI27:1:ALLSTARGO")
}

record(fanout, "MGNT:LI27:1:ALLSTARGO") {
  field(LNK1, "MGNT:LI27:1:ALLBENDSGO")
  field(LNK2, "MGNT:LI27:1:ALLBTRMSGO")
  field(LNK3, "MGNT:LI27:1:ALLLGPSSGO")
  field(LNK4, "MGNT:LI27:1:ALLQUADSGO")
  field(LNK5, "MGNT:LI27:1:ALLXCORSGO")
  field(LNK6, "MGNT:LI27:1:ALLYCORSGO")
  field(FLNK, "MGNT:LI27:1:ALLSTARGO_2")
}
record(fanout, "MGNT:LI27:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:LI27:1:ALLSOLNSGO")
  field(LNK2, "MGNT:LI27:1:ALLKICKSGO")
  field(LNK3, "MGNT:LI27:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:LI27:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:LI27:1:BENDSWITCH")
}

record(seq, "MGNT:LI27:1:BENDSWITCH") {
  field(DOL1, "MGNT:LI27:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:LI27:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI27:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI27:1:BENDCTRL")
}

record(seq, "MGNT:LI27:1:ALLBENDSGO") {
  field(DOL1, "MGNT:LI27:1:ALLSTAR")
  field(LNK1, "MGNT:LI27:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:LI27:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI27:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI27:1:BENDCTRL",20,10,0,0,"MGNT:LI27:1:BENDCTRL")
#! Field("MGNT:LI27:1:BENDCTRL.FLNK",16777215,1,"MGNT:LI27:1:BENDCTRL.FLNK")
#! Link("MGNT:LI27:1:BENDCTRL.FLNK","MGNT:LI27:1:BENDSWITCH")
#! Field("MGNT:LI27:1:BENDCTRL.FFVL",16777215,1,"MGNT:LI27:1:BENDCTRL.FFVL")
#! Record("MGNT:LI27:1:BENDSWITCH",460,322,0,0,"MGNT:LI27:1:BENDSWITCH")
#! Field("MGNT:LI27:1:BENDSWITCH.DOL1",16777215,0,"MGNT:LI27:1:BENDSWITCH.DOL1")
#! Link("MGNT:LI27:1:BENDSWITCH.DOL1","MGNT:LI27:1:BENDCTRL.FFVL")
#! Field("MGNT:LI27:1:BENDSWITCH.LNK1",16777215,1,"MGNT:LI27:1:BENDSWITCH.LNK1")
#! Field("MGNT:LI27:1:BENDSWITCH.FLNK",16777215,1,"MGNT:LI27:1:BENDSWITCH.FLNK")
#! Record("MGNT:LI27:1:ALLBENDSGO",240,96,0,0,"MGNT:LI27:1:ALLBENDSGO")
#! Field("MGNT:LI27:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:LI27:1:ALLBENDSGO.DOL1")
#! Field("MGNT:LI27:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:LI27:1:ALLBENDSGO.LNK1")
#! Link("MGNT:LI27:1:ALLBENDSGO.LNK1","MGNT:LI27:1:ALLBENDS.VAL")
#! Record("MGNT:LI27:1:ALLBENDS",540,102,0,0,"MGNT:LI27:1:ALLBENDS")
#! Field("MGNT:LI27:1:ALLBENDS.VAL",16777215,0,"MGNT:LI27:1:ALLBENDS.VAL")
#! Field("MGNT:LI27:1:ALLBENDS.FLNK",16777215,1,"MGNT:LI27:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:LI27:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI27:1:BTRMSWITCH")
}

record(seq, "MGNT:LI27:1:BTRMSWITCH") {
  field(DOL1, "MGNT:LI27:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:LI27:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI27:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI27:1:BTRMCTRL")
}

record(seq, "MGNT:LI27:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:LI27:1:ALLSTAR")
  field(LNK1, "MGNT:LI27:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:LI27:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI27:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI27:1:BTRMCTRL",20,10,0,0,"MGNT:LI27:1:BTRMCTRL")
#! Field("MGNT:LI27:1:BTRMCTRL.FLNK",16777215,1,"MGNT:LI27:1:BTRMCTRL.FLNK")
#! Link("MGNT:LI27:1:BTRMCTRL.FLNK","MGNT:LI27:1:BTRMSWITCH")
#! Field("MGNT:LI27:1:BTRMCTRL.FFVL",16777215,1,"MGNT:LI27:1:BTRMCTRL.FFVL")
#! Record("MGNT:LI27:1:BTRMSWITCH",460,322,0,0,"MGNT:LI27:1:BTRMSWITCH")
#! Field("MGNT:LI27:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:LI27:1:BTRMSWITCH.DOL1")
#! Link("MGNT:LI27:1:BTRMSWITCH.DOL1","MGNT:LI27:1:BTRMCTRL.FFVL")
#! Field("MGNT:LI27:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:LI27:1:BTRMSWITCH.LNK1")
#! Field("MGNT:LI27:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:LI27:1:BTRMSWITCH.FLNK")
#! Record("MGNT:LI27:1:ALLBTRMSGO",240,96,0,0,"MGNT:LI27:1:ALLBTRMSGO")
#! Field("MGNT:LI27:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:LI27:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:LI27:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:LI27:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:LI27:1:ALLBTRMSGO.LNK1","MGNT:LI27:1:ALLBTRMS.VAL")
#! Record("MGNT:LI27:1:ALLBTRMS",540,102,0,0,"MGNT:LI27:1:ALLBTRMS")
#! Field("MGNT:LI27:1:ALLBTRMS.VAL",16777215,0,"MGNT:LI27:1:ALLBTRMS.VAL")
#! Field("MGNT:LI27:1:ALLBTRMS.FLNK",16777215,1,"MGNT:LI27:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:LI27:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI27:1:LGPSSWITCH")
}

record(seq, "MGNT:LI27:1:LGPSSWITCH") {
  field(DOL1, "MGNT:LI27:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:LI27:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI27:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI27:1:LGPSCTRL")
}

record(seq, "MGNT:LI27:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:LI27:1:ALLSTAR")
  field(LNK1, "MGNT:LI27:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:LI27:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI27:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI27:1:LGPSCTRL",20,10,0,0,"MGNT:LI27:1:LGPSCTRL")
#! Field("MGNT:LI27:1:LGPSCTRL.FLNK",16777215,1,"MGNT:LI27:1:LGPSCTRL.FLNK")
#! Link("MGNT:LI27:1:LGPSCTRL.FLNK","MGNT:LI27:1:LGPSSWITCH")
#! Field("MGNT:LI27:1:LGPSCTRL.FFVL",16777215,1,"MGNT:LI27:1:LGPSCTRL.FFVL")
#! Record("MGNT:LI27:1:LGPSSWITCH",460,322,0,0,"MGNT:LI27:1:LGPSSWITCH")
#! Field("MGNT:LI27:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:LI27:1:LGPSSWITCH.DOL1")
#! Link("MGNT:LI27:1:LGPSSWITCH.DOL1","MGNT:LI27:1:LGPSCTRL.FFVL")
#! Field("MGNT:LI27:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:LI27:1:LGPSSWITCH.LNK1")
#! Field("MGNT:LI27:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:LI27:1:LGPSSWITCH.FLNK")
#! Record("MGNT:LI27:1:ALLLGPSSGO",240,96,0,0,"MGNT:LI27:1:ALLLGPSSGO")
#! Field("MGNT:LI27:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:LI27:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:LI27:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:LI27:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:LI27:1:ALLLGPSSGO.LNK1","MGNT:LI27:1:ALLLGPSS.VAL")
#! Record("MGNT:LI27:1:ALLLGPSS",540,102,0,0,"MGNT:LI27:1:ALLLGPSS")
#! Field("MGNT:LI27:1:ALLLGPSS.VAL",16777215,0,"MGNT:LI27:1:ALLLGPSS.VAL")
#! Field("MGNT:LI27:1:ALLLGPSS.FLNK",16777215,1,"MGNT:LI27:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:LI27:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:LI27:1:QUADSWITCH")
}

record(seq, "MGNT:LI27:1:QUADSWITCH") {
  field(DOL1, "MGNT:LI27:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:LI27:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI27:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI27:1:QUADCTRL")
}

record(seq, "MGNT:LI27:1:ALLQUADSGO") {
  field(DOL1, "MGNT:LI27:1:ALLSTAR")
  field(LNK1, "MGNT:LI27:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:LI27:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI27:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI27:1:QUADCTRL",20,10,0,0,"MGNT:LI27:1:QUADCTRL")
#! Field("MGNT:LI27:1:QUADCTRL.FLNK",16777215,1,"MGNT:LI27:1:QUADCTRL.FLNK")
#! Link("MGNT:LI27:1:QUADCTRL.FLNK","MGNT:LI27:1:QUADSWITCH")
#! Field("MGNT:LI27:1:QUADCTRL.FFVL",16777215,1,"MGNT:LI27:1:QUADCTRL.FFVL")
#! Record("MGNT:LI27:1:QUADSWITCH",460,322,0,0,"MGNT:LI27:1:QUADSWITCH")
#! Field("MGNT:LI27:1:QUADSWITCH.DOL1",16777215,0,"MGNT:LI27:1:QUADSWITCH.DOL1")
#! Link("MGNT:LI27:1:QUADSWITCH.DOL1","MGNT:LI27:1:QUADCTRL.FFVL")
#! Field("MGNT:LI27:1:QUADSWITCH.LNK1",16777215,1,"MGNT:LI27:1:QUADSWITCH.LNK1")
#! Field("MGNT:LI27:1:QUADSWITCH.FLNK",16777215,1,"MGNT:LI27:1:QUADSWITCH.FLNK")
#! Record("MGNT:LI27:1:ALLQUADSGO",240,96,0,0,"MGNT:LI27:1:ALLQUADSGO")
#! Field("MGNT:LI27:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:LI27:1:ALLQUADSGO.DOL1")
#! Field("MGNT:LI27:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:LI27:1:ALLQUADSGO.LNK1")
#! Link("MGNT:LI27:1:ALLQUADSGO.LNK1","MGNT:LI27:1:ALLQUADS.VAL")
#! Record("MGNT:LI27:1:ALLQUADS",540,102,0,0,"MGNT:LI27:1:ALLQUADS")
#! Field("MGNT:LI27:1:ALLQUADS.VAL",16777215,0,"MGNT:LI27:1:ALLQUADS.VAL")
#! Field("MGNT:LI27:1:ALLQUADS.FLNK",16777215,1,"MGNT:LI27:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:LI27:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:LI27:1:XCORSWITCH")
}

record(seq, "MGNT:LI27:1:XCORSWITCH") {
  field(DOL1, "MGNT:LI27:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:LI27:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI27:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI27:1:XCORCTRL")
}

record(seq, "MGNT:LI27:1:ALLXCORSGO") {
  field(DOL1, "MGNT:LI27:1:ALLSTAR")
  field(LNK1, "MGNT:LI27:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:LI27:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI27:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI27:1:XCORCTRL",20,10,0,0,"MGNT:LI27:1:XCORCTRL")
#! Field("MGNT:LI27:1:XCORCTRL.FLNK",16777215,1,"MGNT:LI27:1:XCORCTRL.FLNK")
#! Link("MGNT:LI27:1:XCORCTRL.FLNK","MGNT:LI27:1:XCORSWITCH")
#! Field("MGNT:LI27:1:XCORCTRL.FFVL",16777215,1,"MGNT:LI27:1:XCORCTRL.FFVL")
#! Record("MGNT:LI27:1:XCORSWITCH",460,322,0,0,"MGNT:LI27:1:XCORSWITCH")
#! Field("MGNT:LI27:1:XCORSWITCH.DOL1",16777215,0,"MGNT:LI27:1:XCORSWITCH.DOL1")
#! Link("MGNT:LI27:1:XCORSWITCH.DOL1","MGNT:LI27:1:XCORCTRL.FFVL")
#! Field("MGNT:LI27:1:XCORSWITCH.LNK1",16777215,1,"MGNT:LI27:1:XCORSWITCH.LNK1")
#! Field("MGNT:LI27:1:XCORSWITCH.FLNK",16777215,1,"MGNT:LI27:1:XCORSWITCH.FLNK")
#! Record("MGNT:LI27:1:ALLXCORSGO",240,96,0,0,"MGNT:LI27:1:ALLXCORSGO")
#! Field("MGNT:LI27:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:LI27:1:ALLXCORSGO.DOL1")
#! Field("MGNT:LI27:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:LI27:1:ALLXCORSGO.LNK1")
#! Link("MGNT:LI27:1:ALLXCORSGO.LNK1","MGNT:LI27:1:ALLXCORS.VAL")
#! Record("MGNT:LI27:1:ALLXCORS",540,102,0,0,"MGNT:LI27:1:ALLXCORS")
#! Field("MGNT:LI27:1:ALLXCORS.VAL",16777215,0,"MGNT:LI27:1:ALLXCORS.VAL")
#! Field("MGNT:LI27:1:ALLXCORS.FLNK",16777215,1,"MGNT:LI27:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:LI27:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:LI27:1:YCORSWITCH")
}

record(seq, "MGNT:LI27:1:YCORSWITCH") {
  field(DOL1, "MGNT:LI27:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:LI27:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI27:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI27:1:YCORCTRL")
}

record(seq, "MGNT:LI27:1:ALLYCORSGO") {
  field(DOL1, "MGNT:LI27:1:ALLSTAR")
  field(LNK1, "MGNT:LI27:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:LI27:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI27:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI27:1:YCORCTRL",20,10,0,0,"MGNT:LI27:1:YCORCTRL")
#! Field("MGNT:LI27:1:YCORCTRL.FLNK",16777215,1,"MGNT:LI27:1:YCORCTRL.FLNK")
#! Link("MGNT:LI27:1:YCORCTRL.FLNK","MGNT:LI27:1:YCORSWITCH")
#! Field("MGNT:LI27:1:YCORCTRL.FFVL",16777215,1,"MGNT:LI27:1:YCORCTRL.FFVL")
#! Record("MGNT:LI27:1:YCORSWITCH",460,322,0,0,"MGNT:LI27:1:YCORSWITCH")
#! Field("MGNT:LI27:1:YCORSWITCH.DOL1",16777215,0,"MGNT:LI27:1:YCORSWITCH.DOL1")
#! Link("MGNT:LI27:1:YCORSWITCH.DOL1","MGNT:LI27:1:YCORCTRL.FFVL")
#! Field("MGNT:LI27:1:YCORSWITCH.LNK1",16777215,1,"MGNT:LI27:1:YCORSWITCH.LNK1")
#! Field("MGNT:LI27:1:YCORSWITCH.FLNK",16777215,1,"MGNT:LI27:1:YCORSWITCH.FLNK")
#! Record("MGNT:LI27:1:ALLYCORSGO",240,96,0,0,"MGNT:LI27:1:ALLYCORSGO")
#! Field("MGNT:LI27:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:LI27:1:ALLYCORSGO.DOL1")
#! Field("MGNT:LI27:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:LI27:1:ALLYCORSGO.LNK1")
#! Link("MGNT:LI27:1:ALLYCORSGO.LNK1","MGNT:LI27:1:ALLYCORS.VAL")
#! Record("MGNT:LI27:1:ALLYCORS",540,102,0,0,"MGNT:LI27:1:ALLYCORS")
#! Field("MGNT:LI27:1:ALLYCORS.VAL",16777215,0,"MGNT:LI27:1:ALLYCORS.VAL")
#! Field("MGNT:LI27:1:ALLYCORS.FLNK",16777215,1,"MGNT:LI27:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:LI27:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:LI27:1:SOLNSWITCH")
}

record(seq, "MGNT:LI27:1:SOLNSWITCH") {
  field(DOL1, "MGNT:LI27:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:LI27:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI27:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI27:1:SOLNCTRL")
}

record(seq, "MGNT:LI27:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:LI27:1:ALLSTAR")
  field(LNK1, "MGNT:LI27:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:LI27:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI27:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI27:1:SOLNCTRL",20,10,0,0,"MGNT:LI27:1:SOLNCTRL")
#! Field("MGNT:LI27:1:SOLNCTRL.FLNK",16777215,1,"MGNT:LI27:1:SOLNCTRL.FLNK")
#! Link("MGNT:LI27:1:SOLNCTRL.FLNK","MGNT:LI27:1:SOLNSWITCH")
#! Field("MGNT:LI27:1:SOLNCTRL.FFVL",16777215,1,"MGNT:LI27:1:SOLNCTRL.FFVL")
#! Record("MGNT:LI27:1:SOLNSWITCH",460,322,0,0,"MGNT:LI27:1:SOLNSWITCH")
#! Field("MGNT:LI27:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:LI27:1:SOLNSWITCH.DOL1")
#! Link("MGNT:LI27:1:SOLNSWITCH.DOL1","MGNT:LI27:1:SOLNCTRL.FFVL")
#! Field("MGNT:LI27:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:LI27:1:SOLNSWITCH.LNK1")
#! Field("MGNT:LI27:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:LI27:1:SOLNSWITCH.FLNK")
#! Record("MGNT:LI27:1:ALLSOLNSGO",240,96,0,0,"MGNT:LI27:1:ALLSOLNSGO")
#! Field("MGNT:LI27:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:LI27:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:LI27:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:LI27:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:LI27:1:ALLSOLNSGO.LNK1","MGNT:LI27:1:ALLSOLNS.VAL")
#! Record("MGNT:LI27:1:ALLSOLNS",540,102,0,0,"MGNT:LI27:1:ALLSOLNS")
#! Field("MGNT:LI27:1:ALLSOLNS.VAL",16777215,0,"MGNT:LI27:1:ALLSOLNS.VAL")
#! Field("MGNT:LI27:1:ALLSOLNS.FLNK",16777215,1,"MGNT:LI27:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:LI27:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:LI27:1:KICKSWITCH")
}

record(seq, "MGNT:LI27:1:KICKSWITCH") {
  field(DOL1, "MGNT:LI27:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:LI27:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI27:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI27:1:KICKCTRL")
}

record(seq, "MGNT:LI27:1:ALLKICKSGO") {
  field(DOL1, "MGNT:LI27:1:ALLSTAR")
  field(LNK1, "MGNT:LI27:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:LI27:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI27:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI27:1:KICKCTRL",20,10,0,0,"MGNT:LI27:1:KICKCTRL")
#! Field("MGNT:LI27:1:KICKCTRL.FLNK",16777215,1,"MGNT:LI27:1:KICKCTRL.FLNK")
#! Link("MGNT:LI27:1:KICKCTRL.FLNK","MGNT:LI27:1:KICKSWITCH")
#! Field("MGNT:LI27:1:KICKCTRL.FFVL",16777215,1,"MGNT:LI27:1:KICKCTRL.FFVL")
#! Record("MGNT:LI27:1:KICKSWITCH",460,322,0,0,"MGNT:LI27:1:KICKSWITCH")
#! Field("MGNT:LI27:1:KICKSWITCH.DOL1",16777215,0,"MGNT:LI27:1:KICKSWITCH.DOL1")
#! Link("MGNT:LI27:1:KICKSWITCH.DOL1","MGNT:LI27:1:KICKCTRL.FFVL")
#! Field("MGNT:LI27:1:KICKSWITCH.LNK1",16777215,1,"MGNT:LI27:1:KICKSWITCH.LNK1")
#! Field("MGNT:LI27:1:KICKSWITCH.FLNK",16777215,1,"MGNT:LI27:1:KICKSWITCH.FLNK")
#! Record("MGNT:LI27:1:ALLKICKSGO",240,96,0,0,"MGNT:LI27:1:ALLKICKSGO")
#! Field("MGNT:LI27:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:LI27:1:ALLKICKSGO.DOL1")
#! Field("MGNT:LI27:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:LI27:1:ALLKICKSGO.LNK1")
#! Link("MGNT:LI27:1:ALLKICKSGO.LNK1","MGNT:LI27:1:ALLKICKS.VAL")
#! Record("MGNT:LI27:1:ALLKICKS",540,102,0,0,"MGNT:LI27:1:ALLKICKS")
#! Field("MGNT:LI27:1:ALLKICKS.VAL",16777215,0,"MGNT:LI27:1:ALLKICKS.VAL")
#! Field("MGNT:LI27:1:ALLKICKS.FLNK",16777215,1,"MGNT:LI27:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:LI27:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:LI27:1:SEXTSWITCH")
}

record(seq, "MGNT:LI27:1:SEXTSWITCH") {
  field(DOL1, "MGNT:LI27:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:LI27:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI27:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI27:1:SEXTCTRL")
}

record(seq, "MGNT:LI27:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:LI27:1:ALLSTAR")
  field(LNK1, "MGNT:LI27:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:LI27:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI27:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI27:1:SEXTCTRL",20,10,0,0,"MGNT:LI27:1:SEXTCTRL")
#! Field("MGNT:LI27:1:SEXTCTRL.FLNK",16777215,1,"MGNT:LI27:1:SEXTCTRL.FLNK")
#! Link("MGNT:LI27:1:SEXTCTRL.FLNK","MGNT:LI27:1:SEXTSWITCH")
#! Field("MGNT:LI27:1:SEXTCTRL.FFVL",16777215,1,"MGNT:LI27:1:SEXTCTRL.FFVL")
#! Record("MGNT:LI27:1:SEXTSWITCH",460,322,0,0,"MGNT:LI27:1:SEXTSWITCH")
#! Field("MGNT:LI27:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:LI27:1:SEXTSWITCH.DOL1")
#! Link("MGNT:LI27:1:SEXTSWITCH.DOL1","MGNT:LI27:1:SEXTCTRL.FFVL")
#! Field("MGNT:LI27:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:LI27:1:SEXTSWITCH.LNK1")
#! Field("MGNT:LI27:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:LI27:1:SEXTSWITCH.FLNK")
#! Record("MGNT:LI27:1:ALLSEXTSGO",240,96,0,0,"MGNT:LI27:1:ALLSEXTSGO")
#! Field("MGNT:LI27:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:LI27:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:LI27:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:LI27:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:LI27:1:ALLSEXTSGO.LNK1","MGNT:LI27:1:ALLSEXTS.VAL")
#! Record("MGNT:LI27:1:ALLSEXTS",540,102,0,0,"MGNT:LI27:1:ALLSEXTS")
#! Field("MGNT:LI27:1:ALLSEXTS.VAL",16777215,0,"MGNT:LI27:1:ALLSEXTS.VAL")
#! Field("MGNT:LI27:1:ALLSEXTS.FLNK",16777215,1,"MGNT:LI27:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record (seq, "MGNT:LI27:1:ALLBENDSSEL"){
}
record (seq, "MGNT:LI27:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:LI27:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:LI27:1:ALLKICKSSEL"){
}
record (seq, "MGNT:LI27:1:ALLSEXTSSEL"){
}

record (seq, "MGNT:LI27:1:ALLLGPSSSEL"){
  field (DOL1, "MGNT:LI27:1:ALLLGPSS")
  field (LNK1, "LGPS:LI27:2:SELECT CPP NMS")
}

record (seq, "MGNT:LI27:1:ALLQUADSSEL"){
  field (DOL1, "MGNT:LI27:1:ALLQUADS")
  field (DOL2, "MGNT:LI27:1:ALLQUADS")
  field (DOL3, "MGNT:LI27:1:ALLQUADS")
  field (DOL4, "MGNT:LI27:1:ALLQUADS")
  field (DOL5, "MGNT:LI27:1:ALLQUADS")
  field (DOL6, "MGNT:LI27:1:ALLQUADS")
  field (DOL7, "MGNT:LI27:1:ALLQUADS")
  field (DOL8, "MGNT:LI27:1:ALLQUADS")
  field (LNK1, "QUAD:LI27:201:SELECT CPP NMS")
  field (LNK2, "QUAD:LI27:301:SELECT CPP NMS")
  field (LNK3, "QUAD:LI27:401:SELECT CPP NMS")
  field (LNK4, "QUAD:LI27:501:SELECT CPP NMS")
  field (LNK5, "QUAD:LI27:601:SELECT CPP NMS")
  field (LNK6, "QUAD:LI27:701:SELECT CPP NMS")
  field (LNK7, "QUAD:LI27:801:SELECT CPP NMS")
  field (LNK8, "QUAD:LI27:901:SELECT CPP NMS")
}

record (seq, "MGNT:LI27:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:LI27:1:ALLXCORS")
  field (DOL2, "MGNT:LI27:1:ALLXCORS")
  field (DOL3, "MGNT:LI27:1:ALLXCORS")
  field (DOL4, "MGNT:LI27:1:ALLXCORS")
  field (DOL5, "MGNT:LI27:1:ALLXCORS")
  field (DOL6, "MGNT:LI27:1:ALLXCORS")
  field (DOL7, "MGNT:LI27:1:ALLXCORS")
  field (DOL8, "MGNT:LI27:1:ALLXCORS")
  field (LNK1, "XCOR:LI27:202:SELECT CPP NMS")
  field (LNK2, "XCOR:LI27:302:SELECT CPP NMS")
  field (LNK3, "XCOR:LI27:402:SELECT CPP NMS")
  field (LNK4, "XCOR:LI27:502:SELECT CPP NMS")
  field (LNK5, "XCOR:LI27:602:SELECT CPP NMS")
  field (LNK6, "XCOR:LI27:702:SELECT CPP NMS")
  field (LNK7, "XCOR:LI27:802:SELECT CPP NMS")
  field (LNK8, "XCOR:LI27:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI27:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:LI27:1:ALLYCORS")
  field (DOL2, "MGNT:LI27:1:ALLYCORS")
  field (DOL3, "MGNT:LI27:1:ALLYCORS")
  field (DOL4, "MGNT:LI27:1:ALLYCORS")
  field (DOL5, "MGNT:LI27:1:ALLYCORS")
  field (DOL6, "MGNT:LI27:1:ALLYCORS")
  field (DOL7, "MGNT:LI27:1:ALLYCORS")
  field (DOL8, "MGNT:LI27:1:ALLYCORS")
  field (LNK1, "YCOR:LI27:203:SELECT CPP NMS")
  field (LNK2, "YCOR:LI27:303:SELECT CPP NMS")
  field (LNK3, "YCOR:LI27:403:SELECT CPP NMS")
  field (LNK4, "YCOR:LI27:503:SELECT CPP NMS")
  field (LNK5, "YCOR:LI27:603:SELECT CPP NMS")
  field (LNK6, "YCOR:LI27:703:SELECT CPP NMS")
  field (LNK7, "YCOR:LI27:803:SELECT CPP NMS")
  field (LNK8, "YCOR:LI27:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI27:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (LNK1, "MGNT:LI27:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:LI27:1:QUADFUNCGO.PROC")
  field (LNK3, "MGNT:LI27:1:XCORFUNCGO.PROC")
  field (LNK4, "MGNT:LI27:1:YCORFUNCGO.PROC")
  field (LNK5, "MGNT:LI27:1:LGPSFUNCGO.PROC")
  field (LNK6, "MGNT:LI27:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:LI27:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI27:1:QUADFUNCGO") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI27:201:ALLFUNCGO")
  field (LNK2, "QUAD:LI27:301:ALLFUNCGO")
  field (LNK3, "QUAD:LI27:401:ALLFUNCGO")
  field (LNK4, "QUAD:LI27:501:ALLFUNCGO")
  field (LNK5, "QUAD:LI27:601:ALLFUNCGO")
  field (LNK6, "QUAD:LI27:701:ALLFUNCGO")
  field (FLNK, "MGNT:LI27:1:QUADFUNCGO1")
}

record (fanout, "MGNT:LI27:1:QUADFUNCGO1") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI27:801:ALLFUNCGO")
  field (LNK2, "QUAD:LI27:901:ALLFUNCGO")
  field (FLNK, "MGNT:LI27:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI27:1:XCORFUNCGO") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI27:202:ALLFUNCGO")
  field (LNK2, "XCOR:LI27:302:ALLFUNCGO")
  field (LNK3, "XCOR:LI27:402:ALLFUNCGO")
  field (LNK4, "XCOR:LI27:502:ALLFUNCGO")
  field (LNK5, "XCOR:LI27:602:ALLFUNCGO")
  field (LNK6, "XCOR:LI27:702:ALLFUNCGO")
  field (FLNK, "MGNT:LI27:1:XCORFUNCGO1")
}

record (fanout, "MGNT:LI27:1:XCORFUNCGO1") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI27:802:ALLFUNCGO")
  field (LNK2, "XCOR:LI27:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI27:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI27:1:YCORFUNCGO") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI27:203:ALLFUNCGO")
  field (LNK2, "YCOR:LI27:303:ALLFUNCGO")
  field (LNK3, "YCOR:LI27:403:ALLFUNCGO")
  field (LNK4, "YCOR:LI27:503:ALLFUNCGO")
  field (LNK5, "YCOR:LI27:603:ALLFUNCGO")
  field (LNK6, "YCOR:LI27:703:ALLFUNCGO")
  field (FLNK, "MGNT:LI27:1:YCORFUNCGO1")
}

record (fanout, "MGNT:LI27:1:YCORFUNCGO1") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI27:803:ALLFUNCGO")
  field (LNK2, "YCOR:LI27:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI27:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI27:1:LGPSFUNCGO"){
  field (DESC, "Process LGPS CTRL func")
  field (LNK1, "LGPS:LI27:2:ALLFUNCGO")
  field (FLNK, "MGNT:LI27:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI27:1:BENDFUNCGO"){
  field (DESC, "Process BEND CTRL func")
  field (FLNK, "MGNT:LI27:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI27:1:BTRMFUNCGO"){
  field (DESC, "Process BTRM CTRL func")
  field (FLNK, "MGNT:LI27:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI27:1:SOLNFUNCGO"){
  field (DESC, "Process SOLN CTRL func")
  field (FLNK, "MGNT:LI27:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI27:1:KICKFUNCGO"){
  field (DESC, "Process KICK CTRL func")
  field (FLNK, "MGNT:LI27:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI27:1:SEXTFUNCGO"){
  field (DESC, "Process SEXT CTRL func")
  field (FLNK, "MGNT:LI27:1:CTRLCLEAR")
}




#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LI27:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "LGPS:LI27:2:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LI27:2:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LI27:2:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LI27:2:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LI27:2:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LI27:2:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LI27:2:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LI27:2:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LI27:2:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LI27:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LI27:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LI27:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LI27:2:EDES.PROC PP")
    field(LNK2, "LGPS:LI27:2:EACT.PROC PP")
    field(LNK3, "LGPS:LI27:2:EERR.DISA PP")
    field(LNK4, "LGPS:LI27:2:ECON.PROC PP")
    field(LNK5, "LGPS:LI27:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:LI27:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:LI27:2:BLEM.PROC PP")
    field(LNK8, "LGPS:LI27:2:BMOD.PROC PP")
    field(LNK9, "LGPS:LI27:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LI27:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LI27:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LI27:2:BMAX")
  field(DOL2, "LGPS:LI27:2:BMAX")
  field(DOL3, "LGPS:LI27:2:BMAX")
  field(DOL4, "LGPS:LI27:2:BMIN")
  field(DOL5, "LGPS:LI27:2:BMIN")
  field(DOL6, "LGPS:LI27:2:BMIN")
  field(LNK1, "LGPS:LI27:2:BMAGX.HOPR")
  field(LNK2, "LGPS:LI27:2:BMAGY.HOPR")
  field(LNK3, "LGPS:LI27:2:BLEM.HOPR")
  field(LNK4, "LGPS:LI27:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LI27:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LI27:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LI27:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LI27:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LI27:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LI27:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LI27:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI27:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI27:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI27:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI27:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI27:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LI27:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LI27:2:EDES NPP MS")
  field(INPB, "LGPS:LI27:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI27:201:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI27:201:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI27:201:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI27:201:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI27:201:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI27:201:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI27:201:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI27:201:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI27:201:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI27:201:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI27:201:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI27:201:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI27:201:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI27:201:EDES.PROC PP")
    field(LNK2, "QUAD:LI27:201:EACT.PROC PP")
    field(LNK3, "QUAD:LI27:201:EERR.DISA PP")
    field(LNK4, "QUAD:LI27:201:ECON.PROC PP")
    field(LNK5, "QUAD:LI27:201:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI27:201:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI27:201:BLEM.PROC PP")
    field(LNK8, "QUAD:LI27:201:BMOD.PROC PP")
    field(LNK9, "QUAD:LI27:201:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI27:201:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI27:201:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI27:201:BMAX")
  field(DOL2, "QUAD:LI27:201:BMAX")
  field(DOL3, "QUAD:LI27:201:BMAX")
  field(DOL4, "QUAD:LI27:201:BMIN")
  field(DOL5, "QUAD:LI27:201:BMIN")
  field(DOL6, "QUAD:LI27:201:BMIN")
  field(LNK1, "QUAD:LI27:201:BMAGX.HOPR")
  field(LNK2, "QUAD:LI27:201:BMAGY.HOPR")
  field(LNK3, "QUAD:LI27:201:BLEM.HOPR")
  field(LNK4, "QUAD:LI27:201:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI27:201:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI27:201:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:201:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:201:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI27:201:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI27:201:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI27:201:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:201:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:201:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:201:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:201:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:201:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI27:201:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI27:201:EDES NPP MS")
  field(INPB, "QUAD:LI27:201:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI27:301:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI27:301:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI27:301:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI27:301:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI27:301:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI27:301:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI27:301:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI27:301:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI27:301:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI27:301:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI27:301:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI27:301:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI27:301:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI27:301:EDES.PROC PP")
    field(LNK2, "QUAD:LI27:301:EACT.PROC PP")
    field(LNK3, "QUAD:LI27:301:EERR.DISA PP")
    field(LNK4, "QUAD:LI27:301:ECON.PROC PP")
    field(LNK5, "QUAD:LI27:301:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI27:301:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI27:301:BLEM.PROC PP")
    field(LNK8, "QUAD:LI27:301:BMOD.PROC PP")
    field(LNK9, "QUAD:LI27:301:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI27:301:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI27:301:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI27:301:BMAX")
  field(DOL2, "QUAD:LI27:301:BMAX")
  field(DOL3, "QUAD:LI27:301:BMAX")
  field(DOL4, "QUAD:LI27:301:BMIN")
  field(DOL5, "QUAD:LI27:301:BMIN")
  field(DOL6, "QUAD:LI27:301:BMIN")
  field(LNK1, "QUAD:LI27:301:BMAGX.HOPR")
  field(LNK2, "QUAD:LI27:301:BMAGY.HOPR")
  field(LNK3, "QUAD:LI27:301:BLEM.HOPR")
  field(LNK4, "QUAD:LI27:301:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI27:301:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI27:301:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:301:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:301:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI27:301:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI27:301:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI27:301:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:301:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:301:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:301:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:301:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:301:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI27:301:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI27:301:EDES NPP MS")
  field(INPB, "QUAD:LI27:301:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI27:401:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI27:401:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI27:401:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI27:401:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI27:401:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI27:401:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI27:401:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI27:401:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI27:401:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI27:401:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI27:401:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI27:401:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI27:401:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI27:401:EDES.PROC PP")
    field(LNK2, "QUAD:LI27:401:EACT.PROC PP")
    field(LNK3, "QUAD:LI27:401:EERR.DISA PP")
    field(LNK4, "QUAD:LI27:401:ECON.PROC PP")
    field(LNK5, "QUAD:LI27:401:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI27:401:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI27:401:BLEM.PROC PP")
    field(LNK8, "QUAD:LI27:401:BMOD.PROC PP")
    field(LNK9, "QUAD:LI27:401:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI27:401:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI27:401:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI27:401:BMAX")
  field(DOL2, "QUAD:LI27:401:BMAX")
  field(DOL3, "QUAD:LI27:401:BMAX")
  field(DOL4, "QUAD:LI27:401:BMIN")
  field(DOL5, "QUAD:LI27:401:BMIN")
  field(DOL6, "QUAD:LI27:401:BMIN")
  field(LNK1, "QUAD:LI27:401:BMAGX.HOPR")
  field(LNK2, "QUAD:LI27:401:BMAGY.HOPR")
  field(LNK3, "QUAD:LI27:401:BLEM.HOPR")
  field(LNK4, "QUAD:LI27:401:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI27:401:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI27:401:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:401:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:401:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI27:401:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI27:401:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI27:401:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:401:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:401:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:401:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:401:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:401:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI27:401:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI27:401:EDES NPP MS")
  field(INPB, "QUAD:LI27:401:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI27:501:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI27:501:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI27:501:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI27:501:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI27:501:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI27:501:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI27:501:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI27:501:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI27:501:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI27:501:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI27:501:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI27:501:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI27:501:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI27:501:EDES.PROC PP")
    field(LNK2, "QUAD:LI27:501:EACT.PROC PP")
    field(LNK3, "QUAD:LI27:501:EERR.DISA PP")
    field(LNK4, "QUAD:LI27:501:ECON.PROC PP")
    field(LNK5, "QUAD:LI27:501:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI27:501:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI27:501:BLEM.PROC PP")
    field(LNK8, "QUAD:LI27:501:BMOD.PROC PP")
    field(LNK9, "QUAD:LI27:501:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI27:501:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI27:501:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI27:501:BMAX")
  field(DOL2, "QUAD:LI27:501:BMAX")
  field(DOL3, "QUAD:LI27:501:BMAX")
  field(DOL4, "QUAD:LI27:501:BMIN")
  field(DOL5, "QUAD:LI27:501:BMIN")
  field(DOL6, "QUAD:LI27:501:BMIN")
  field(LNK1, "QUAD:LI27:501:BMAGX.HOPR")
  field(LNK2, "QUAD:LI27:501:BMAGY.HOPR")
  field(LNK3, "QUAD:LI27:501:BLEM.HOPR")
  field(LNK4, "QUAD:LI27:501:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI27:501:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI27:501:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:501:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:501:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI27:501:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI27:501:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI27:501:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:501:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:501:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:501:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:501:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:501:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI27:501:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI27:501:EDES NPP MS")
  field(INPB, "QUAD:LI27:501:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI27:601:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI27:601:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI27:601:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI27:601:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI27:601:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI27:601:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI27:601:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI27:601:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI27:601:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI27:601:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI27:601:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI27:601:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI27:601:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI27:601:EDES.PROC PP")
    field(LNK2, "QUAD:LI27:601:EACT.PROC PP")
    field(LNK3, "QUAD:LI27:601:EERR.DISA PP")
    field(LNK4, "QUAD:LI27:601:ECON.PROC PP")
    field(LNK5, "QUAD:LI27:601:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI27:601:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI27:601:BLEM.PROC PP")
    field(LNK8, "QUAD:LI27:601:BMOD.PROC PP")
    field(LNK9, "QUAD:LI27:601:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI27:601:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI27:601:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI27:601:BMAX")
  field(DOL2, "QUAD:LI27:601:BMAX")
  field(DOL3, "QUAD:LI27:601:BMAX")
  field(DOL4, "QUAD:LI27:601:BMIN")
  field(DOL5, "QUAD:LI27:601:BMIN")
  field(DOL6, "QUAD:LI27:601:BMIN")
  field(LNK1, "QUAD:LI27:601:BMAGX.HOPR")
  field(LNK2, "QUAD:LI27:601:BMAGY.HOPR")
  field(LNK3, "QUAD:LI27:601:BLEM.HOPR")
  field(LNK4, "QUAD:LI27:601:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI27:601:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI27:601:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:601:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:601:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI27:601:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI27:601:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI27:601:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:601:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:601:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:601:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:601:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:601:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI27:601:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI27:601:EDES NPP MS")
  field(INPB, "QUAD:LI27:601:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI27:701:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI27:701:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI27:701:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI27:701:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI27:701:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI27:701:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI27:701:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI27:701:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI27:701:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI27:701:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI27:701:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI27:701:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI27:701:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI27:701:EDES.PROC PP")
    field(LNK2, "QUAD:LI27:701:EACT.PROC PP")
    field(LNK3, "QUAD:LI27:701:EERR.DISA PP")
    field(LNK4, "QUAD:LI27:701:ECON.PROC PP")
    field(LNK5, "QUAD:LI27:701:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI27:701:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI27:701:BLEM.PROC PP")
    field(LNK8, "QUAD:LI27:701:BMOD.PROC PP")
    field(LNK9, "QUAD:LI27:701:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI27:701:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI27:701:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI27:701:BMAX")
  field(DOL2, "QUAD:LI27:701:BMAX")
  field(DOL3, "QUAD:LI27:701:BMAX")
  field(DOL4, "QUAD:LI27:701:BMIN")
  field(DOL5, "QUAD:LI27:701:BMIN")
  field(DOL6, "QUAD:LI27:701:BMIN")
  field(LNK1, "QUAD:LI27:701:BMAGX.HOPR")
  field(LNK2, "QUAD:LI27:701:BMAGY.HOPR")
  field(LNK3, "QUAD:LI27:701:BLEM.HOPR")
  field(LNK4, "QUAD:LI27:701:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI27:701:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI27:701:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:701:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:701:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI27:701:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI27:701:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI27:701:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:701:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:701:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:701:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:701:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:701:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI27:701:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI27:701:EDES NPP MS")
  field(INPB, "QUAD:LI27:701:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI27:801:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI27:801:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI27:801:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI27:801:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI27:801:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI27:801:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI27:801:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI27:801:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI27:801:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI27:801:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI27:801:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI27:801:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI27:801:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI27:801:EDES.PROC PP")
    field(LNK2, "QUAD:LI27:801:EACT.PROC PP")
    field(LNK3, "QUAD:LI27:801:EERR.DISA PP")
    field(LNK4, "QUAD:LI27:801:ECON.PROC PP")
    field(LNK5, "QUAD:LI27:801:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI27:801:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI27:801:BLEM.PROC PP")
    field(LNK8, "QUAD:LI27:801:BMOD.PROC PP")
    field(LNK9, "QUAD:LI27:801:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI27:801:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI27:801:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI27:801:BMAX")
  field(DOL2, "QUAD:LI27:801:BMAX")
  field(DOL3, "QUAD:LI27:801:BMAX")
  field(DOL4, "QUAD:LI27:801:BMIN")
  field(DOL5, "QUAD:LI27:801:BMIN")
  field(DOL6, "QUAD:LI27:801:BMIN")
  field(LNK1, "QUAD:LI27:801:BMAGX.HOPR")
  field(LNK2, "QUAD:LI27:801:BMAGY.HOPR")
  field(LNK3, "QUAD:LI27:801:BLEM.HOPR")
  field(LNK4, "QUAD:LI27:801:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI27:801:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI27:801:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:801:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:801:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI27:801:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI27:801:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI27:801:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:801:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:801:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:801:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:801:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:801:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI27:801:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI27:801:EDES NPP MS")
  field(INPB, "QUAD:LI27:801:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI27:901:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI27:901:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI27:901:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI27:901:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI27:901:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI27:901:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI27:901:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI27:901:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI27:901:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI27:901:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI27:901:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI27:901:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI27:901:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI27:901:EDES.PROC PP")
    field(LNK2, "QUAD:LI27:901:EACT.PROC PP")
    field(LNK3, "QUAD:LI27:901:EERR.DISA PP")
    field(LNK4, "QUAD:LI27:901:ECON.PROC PP")
    field(LNK5, "QUAD:LI27:901:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI27:901:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI27:901:BLEM.PROC PP")
    field(LNK8, "QUAD:LI27:901:BMOD.PROC PP")
    field(LNK9, "QUAD:LI27:901:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI27:901:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI27:901:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI27:901:BMAX")
  field(DOL2, "QUAD:LI27:901:BMAX")
  field(DOL3, "QUAD:LI27:901:BMAX")
  field(DOL4, "QUAD:LI27:901:BMIN")
  field(DOL5, "QUAD:LI27:901:BMIN")
  field(DOL6, "QUAD:LI27:901:BMIN")
  field(LNK1, "QUAD:LI27:901:BMAGX.HOPR")
  field(LNK2, "QUAD:LI27:901:BMAGY.HOPR")
  field(LNK3, "QUAD:LI27:901:BLEM.HOPR")
  field(LNK4, "QUAD:LI27:901:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI27:901:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI27:901:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:901:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI27:901:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI27:901:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI27:901:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI27:901:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:901:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:901:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:901:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI27:901:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI27:901:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI27:901:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI27:901:EDES NPP MS")
  field(INPB, "QUAD:LI27:901:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI27:202:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI27:202:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI27:202:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI27:202:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI27:202:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI27:202:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI27:202:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI27:202:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI27:202:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI27:202:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI27:202:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI27:202:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI27:202:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI27:202:EDES.PROC PP")
    field(LNK2, "XCOR:LI27:202:EACT.PROC PP")
    field(LNK3, "XCOR:LI27:202:EERR.DISA PP")
    field(LNK4, "XCOR:LI27:202:ECON.PROC PP")
    field(LNK5, "XCOR:LI27:202:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI27:202:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI27:202:BLEM.PROC PP")
    field(LNK8, "XCOR:LI27:202:BMOD.PROC PP")
    field(LNK9, "XCOR:LI27:202:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI27:202:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI27:202:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI27:202:BMAX")
  field(DOL2, "XCOR:LI27:202:BMAX")
  field(DOL3, "XCOR:LI27:202:BMAX")
  field(DOL4, "XCOR:LI27:202:BMIN")
  field(DOL5, "XCOR:LI27:202:BMIN")
  field(DOL6, "XCOR:LI27:202:BMIN")
  field(LNK1, "XCOR:LI27:202:BMAGX.HOPR")
  field(LNK2, "XCOR:LI27:202:BMAGY.HOPR")
  field(LNK3, "XCOR:LI27:202:BLEM.HOPR")
  field(LNK4, "XCOR:LI27:202:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI27:202:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI27:202:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:202:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:202:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI27:202:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI27:202:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI27:202:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:202:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:202:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:202:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:202:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:202:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI27:202:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI27:202:EDES NPP MS")
  field(INPB, "XCOR:LI27:202:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI27:302:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI27:302:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI27:302:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI27:302:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI27:302:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI27:302:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI27:302:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI27:302:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI27:302:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI27:302:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI27:302:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI27:302:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI27:302:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI27:302:EDES.PROC PP")
    field(LNK2, "XCOR:LI27:302:EACT.PROC PP")
    field(LNK3, "XCOR:LI27:302:EERR.DISA PP")
    field(LNK4, "XCOR:LI27:302:ECON.PROC PP")
    field(LNK5, "XCOR:LI27:302:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI27:302:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI27:302:BLEM.PROC PP")
    field(LNK8, "XCOR:LI27:302:BMOD.PROC PP")
    field(LNK9, "XCOR:LI27:302:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI27:302:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI27:302:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI27:302:BMAX")
  field(DOL2, "XCOR:LI27:302:BMAX")
  field(DOL3, "XCOR:LI27:302:BMAX")
  field(DOL4, "XCOR:LI27:302:BMIN")
  field(DOL5, "XCOR:LI27:302:BMIN")
  field(DOL6, "XCOR:LI27:302:BMIN")
  field(LNK1, "XCOR:LI27:302:BMAGX.HOPR")
  field(LNK2, "XCOR:LI27:302:BMAGY.HOPR")
  field(LNK3, "XCOR:LI27:302:BLEM.HOPR")
  field(LNK4, "XCOR:LI27:302:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI27:302:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI27:302:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:302:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:302:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI27:302:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI27:302:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI27:302:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:302:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:302:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:302:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:302:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:302:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI27:302:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI27:302:EDES NPP MS")
  field(INPB, "XCOR:LI27:302:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI27:402:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI27:402:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI27:402:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI27:402:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI27:402:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI27:402:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI27:402:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI27:402:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI27:402:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI27:402:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI27:402:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI27:402:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI27:402:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI27:402:EDES.PROC PP")
    field(LNK2, "XCOR:LI27:402:EACT.PROC PP")
    field(LNK3, "XCOR:LI27:402:EERR.DISA PP")
    field(LNK4, "XCOR:LI27:402:ECON.PROC PP")
    field(LNK5, "XCOR:LI27:402:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI27:402:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI27:402:BLEM.PROC PP")
    field(LNK8, "XCOR:LI27:402:BMOD.PROC PP")
    field(LNK9, "XCOR:LI27:402:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI27:402:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI27:402:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI27:402:BMAX")
  field(DOL2, "XCOR:LI27:402:BMAX")
  field(DOL3, "XCOR:LI27:402:BMAX")
  field(DOL4, "XCOR:LI27:402:BMIN")
  field(DOL5, "XCOR:LI27:402:BMIN")
  field(DOL6, "XCOR:LI27:402:BMIN")
  field(LNK1, "XCOR:LI27:402:BMAGX.HOPR")
  field(LNK2, "XCOR:LI27:402:BMAGY.HOPR")
  field(LNK3, "XCOR:LI27:402:BLEM.HOPR")
  field(LNK4, "XCOR:LI27:402:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI27:402:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI27:402:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:402:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:402:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI27:402:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI27:402:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI27:402:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:402:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:402:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:402:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:402:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:402:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI27:402:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI27:402:EDES NPP MS")
  field(INPB, "XCOR:LI27:402:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI27:502:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI27:502:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI27:502:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI27:502:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI27:502:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI27:502:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI27:502:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI27:502:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI27:502:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI27:502:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI27:502:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI27:502:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI27:502:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI27:502:EDES.PROC PP")
    field(LNK2, "XCOR:LI27:502:EACT.PROC PP")
    field(LNK3, "XCOR:LI27:502:EERR.DISA PP")
    field(LNK4, "XCOR:LI27:502:ECON.PROC PP")
    field(LNK5, "XCOR:LI27:502:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI27:502:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI27:502:BLEM.PROC PP")
    field(LNK8, "XCOR:LI27:502:BMOD.PROC PP")
    field(LNK9, "XCOR:LI27:502:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI27:502:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI27:502:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI27:502:BMAX")
  field(DOL2, "XCOR:LI27:502:BMAX")
  field(DOL3, "XCOR:LI27:502:BMAX")
  field(DOL4, "XCOR:LI27:502:BMIN")
  field(DOL5, "XCOR:LI27:502:BMIN")
  field(DOL6, "XCOR:LI27:502:BMIN")
  field(LNK1, "XCOR:LI27:502:BMAGX.HOPR")
  field(LNK2, "XCOR:LI27:502:BMAGY.HOPR")
  field(LNK3, "XCOR:LI27:502:BLEM.HOPR")
  field(LNK4, "XCOR:LI27:502:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI27:502:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI27:502:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:502:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:502:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI27:502:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI27:502:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI27:502:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:502:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:502:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:502:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:502:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:502:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI27:502:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI27:502:EDES NPP MS")
  field(INPB, "XCOR:LI27:502:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI27:602:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI27:602:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI27:602:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI27:602:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI27:602:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI27:602:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI27:602:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI27:602:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI27:602:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI27:602:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI27:602:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI27:602:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI27:602:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI27:602:EDES.PROC PP")
    field(LNK2, "XCOR:LI27:602:EACT.PROC PP")
    field(LNK3, "XCOR:LI27:602:EERR.DISA PP")
    field(LNK4, "XCOR:LI27:602:ECON.PROC PP")
    field(LNK5, "XCOR:LI27:602:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI27:602:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI27:602:BLEM.PROC PP")
    field(LNK8, "XCOR:LI27:602:BMOD.PROC PP")
    field(LNK9, "XCOR:LI27:602:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI27:602:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI27:602:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI27:602:BMAX")
  field(DOL2, "XCOR:LI27:602:BMAX")
  field(DOL3, "XCOR:LI27:602:BMAX")
  field(DOL4, "XCOR:LI27:602:BMIN")
  field(DOL5, "XCOR:LI27:602:BMIN")
  field(DOL6, "XCOR:LI27:602:BMIN")
  field(LNK1, "XCOR:LI27:602:BMAGX.HOPR")
  field(LNK2, "XCOR:LI27:602:BMAGY.HOPR")
  field(LNK3, "XCOR:LI27:602:BLEM.HOPR")
  field(LNK4, "XCOR:LI27:602:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI27:602:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI27:602:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:602:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:602:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI27:602:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI27:602:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI27:602:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:602:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:602:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:602:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:602:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:602:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI27:602:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI27:602:EDES NPP MS")
  field(INPB, "XCOR:LI27:602:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI27:702:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI27:702:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI27:702:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI27:702:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI27:702:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI27:702:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI27:702:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI27:702:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI27:702:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI27:702:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI27:702:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI27:702:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI27:702:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI27:702:EDES.PROC PP")
    field(LNK2, "XCOR:LI27:702:EACT.PROC PP")
    field(LNK3, "XCOR:LI27:702:EERR.DISA PP")
    field(LNK4, "XCOR:LI27:702:ECON.PROC PP")
    field(LNK5, "XCOR:LI27:702:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI27:702:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI27:702:BLEM.PROC PP")
    field(LNK8, "XCOR:LI27:702:BMOD.PROC PP")
    field(LNK9, "XCOR:LI27:702:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI27:702:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI27:702:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI27:702:BMAX")
  field(DOL2, "XCOR:LI27:702:BMAX")
  field(DOL3, "XCOR:LI27:702:BMAX")
  field(DOL4, "XCOR:LI27:702:BMIN")
  field(DOL5, "XCOR:LI27:702:BMIN")
  field(DOL6, "XCOR:LI27:702:BMIN")
  field(LNK1, "XCOR:LI27:702:BMAGX.HOPR")
  field(LNK2, "XCOR:LI27:702:BMAGY.HOPR")
  field(LNK3, "XCOR:LI27:702:BLEM.HOPR")
  field(LNK4, "XCOR:LI27:702:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI27:702:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI27:702:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:702:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:702:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI27:702:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI27:702:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI27:702:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:702:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:702:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:702:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:702:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:702:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI27:702:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI27:702:EDES NPP MS")
  field(INPB, "XCOR:LI27:702:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI27:802:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI27:802:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI27:802:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI27:802:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI27:802:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI27:802:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI27:802:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI27:802:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI27:802:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI27:802:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI27:802:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI27:802:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI27:802:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI27:802:EDES.PROC PP")
    field(LNK2, "XCOR:LI27:802:EACT.PROC PP")
    field(LNK3, "XCOR:LI27:802:EERR.DISA PP")
    field(LNK4, "XCOR:LI27:802:ECON.PROC PP")
    field(LNK5, "XCOR:LI27:802:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI27:802:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI27:802:BLEM.PROC PP")
    field(LNK8, "XCOR:LI27:802:BMOD.PROC PP")
    field(LNK9, "XCOR:LI27:802:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI27:802:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI27:802:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI27:802:BMAX")
  field(DOL2, "XCOR:LI27:802:BMAX")
  field(DOL3, "XCOR:LI27:802:BMAX")
  field(DOL4, "XCOR:LI27:802:BMIN")
  field(DOL5, "XCOR:LI27:802:BMIN")
  field(DOL6, "XCOR:LI27:802:BMIN")
  field(LNK1, "XCOR:LI27:802:BMAGX.HOPR")
  field(LNK2, "XCOR:LI27:802:BMAGY.HOPR")
  field(LNK3, "XCOR:LI27:802:BLEM.HOPR")
  field(LNK4, "XCOR:LI27:802:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI27:802:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI27:802:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:802:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:802:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI27:802:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI27:802:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI27:802:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:802:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:802:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:802:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:802:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:802:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI27:802:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI27:802:EDES NPP MS")
  field(INPB, "XCOR:LI27:802:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI27:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI27:900:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI27:900:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI27:900:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI27:900:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI27:900:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI27:900:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI27:900:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI27:900:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI27:900:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI27:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI27:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI27:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI27:900:EDES.PROC PP")
    field(LNK2, "XCOR:LI27:900:EACT.PROC PP")
    field(LNK3, "XCOR:LI27:900:EERR.DISA PP")
    field(LNK4, "XCOR:LI27:900:ECON.PROC PP")
    field(LNK5, "XCOR:LI27:900:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI27:900:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI27:900:BLEM.PROC PP")
    field(LNK8, "XCOR:LI27:900:BMOD.PROC PP")
    field(LNK9, "XCOR:LI27:900:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI27:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI27:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI27:900:BMAX")
  field(DOL2, "XCOR:LI27:900:BMAX")
  field(DOL3, "XCOR:LI27:900:BMAX")
  field(DOL4, "XCOR:LI27:900:BMIN")
  field(DOL5, "XCOR:LI27:900:BMIN")
  field(DOL6, "XCOR:LI27:900:BMIN")
  field(LNK1, "XCOR:LI27:900:BMAGX.HOPR")
  field(LNK2, "XCOR:LI27:900:BMAGY.HOPR")
  field(LNK3, "XCOR:LI27:900:BLEM.HOPR")
  field(LNK4, "XCOR:LI27:900:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI27:900:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI27:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI27:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI27:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI27:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI27:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI27:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI27:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI27:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI27:900:EDES NPP MS")
  field(INPB, "XCOR:LI27:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI27:203:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI27:203:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI27:203:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI27:203:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI27:203:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI27:203:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI27:203:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI27:203:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI27:203:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI27:203:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI27:203:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI27:203:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI27:203:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI27:203:EDES.PROC PP")
    field(LNK2, "YCOR:LI27:203:EACT.PROC PP")
    field(LNK3, "YCOR:LI27:203:EERR.DISA PP")
    field(LNK4, "YCOR:LI27:203:ECON.PROC PP")
    field(LNK5, "YCOR:LI27:203:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI27:203:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI27:203:BLEM.PROC PP")
    field(LNK8, "YCOR:LI27:203:BMOD.PROC PP")
    field(LNK9, "YCOR:LI27:203:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI27:203:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI27:203:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI27:203:BMAX")
  field(DOL2, "YCOR:LI27:203:BMAX")
  field(DOL3, "YCOR:LI27:203:BMAX")
  field(DOL4, "YCOR:LI27:203:BMIN")
  field(DOL5, "YCOR:LI27:203:BMIN")
  field(DOL6, "YCOR:LI27:203:BMIN")
  field(LNK1, "YCOR:LI27:203:BMAGX.HOPR")
  field(LNK2, "YCOR:LI27:203:BMAGY.HOPR")
  field(LNK3, "YCOR:LI27:203:BLEM.HOPR")
  field(LNK4, "YCOR:LI27:203:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI27:203:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI27:203:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:203:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:203:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI27:203:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI27:203:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI27:203:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:203:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:203:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:203:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:203:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:203:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI27:203:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI27:203:EDES NPP MS")
  field(INPB, "YCOR:LI27:203:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI27:303:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI27:303:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI27:303:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI27:303:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI27:303:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI27:303:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI27:303:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI27:303:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI27:303:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI27:303:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI27:303:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI27:303:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI27:303:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI27:303:EDES.PROC PP")
    field(LNK2, "YCOR:LI27:303:EACT.PROC PP")
    field(LNK3, "YCOR:LI27:303:EERR.DISA PP")
    field(LNK4, "YCOR:LI27:303:ECON.PROC PP")
    field(LNK5, "YCOR:LI27:303:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI27:303:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI27:303:BLEM.PROC PP")
    field(LNK8, "YCOR:LI27:303:BMOD.PROC PP")
    field(LNK9, "YCOR:LI27:303:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI27:303:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI27:303:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI27:303:BMAX")
  field(DOL2, "YCOR:LI27:303:BMAX")
  field(DOL3, "YCOR:LI27:303:BMAX")
  field(DOL4, "YCOR:LI27:303:BMIN")
  field(DOL5, "YCOR:LI27:303:BMIN")
  field(DOL6, "YCOR:LI27:303:BMIN")
  field(LNK1, "YCOR:LI27:303:BMAGX.HOPR")
  field(LNK2, "YCOR:LI27:303:BMAGY.HOPR")
  field(LNK3, "YCOR:LI27:303:BLEM.HOPR")
  field(LNK4, "YCOR:LI27:303:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI27:303:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI27:303:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:303:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:303:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI27:303:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI27:303:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI27:303:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:303:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:303:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:303:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:303:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:303:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI27:303:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI27:303:EDES NPP MS")
  field(INPB, "YCOR:LI27:303:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI27:403:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI27:403:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI27:403:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI27:403:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI27:403:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI27:403:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI27:403:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI27:403:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI27:403:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI27:403:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI27:403:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI27:403:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI27:403:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI27:403:EDES.PROC PP")
    field(LNK2, "YCOR:LI27:403:EACT.PROC PP")
    field(LNK3, "YCOR:LI27:403:EERR.DISA PP")
    field(LNK4, "YCOR:LI27:403:ECON.PROC PP")
    field(LNK5, "YCOR:LI27:403:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI27:403:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI27:403:BLEM.PROC PP")
    field(LNK8, "YCOR:LI27:403:BMOD.PROC PP")
    field(LNK9, "YCOR:LI27:403:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI27:403:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI27:403:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI27:403:BMAX")
  field(DOL2, "YCOR:LI27:403:BMAX")
  field(DOL3, "YCOR:LI27:403:BMAX")
  field(DOL4, "YCOR:LI27:403:BMIN")
  field(DOL5, "YCOR:LI27:403:BMIN")
  field(DOL6, "YCOR:LI27:403:BMIN")
  field(LNK1, "YCOR:LI27:403:BMAGX.HOPR")
  field(LNK2, "YCOR:LI27:403:BMAGY.HOPR")
  field(LNK3, "YCOR:LI27:403:BLEM.HOPR")
  field(LNK4, "YCOR:LI27:403:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI27:403:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI27:403:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:403:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:403:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI27:403:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI27:403:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI27:403:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:403:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:403:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:403:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:403:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:403:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI27:403:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI27:403:EDES NPP MS")
  field(INPB, "YCOR:LI27:403:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI27:503:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI27:503:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI27:503:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI27:503:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI27:503:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI27:503:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI27:503:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI27:503:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI27:503:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI27:503:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI27:503:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI27:503:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI27:503:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI27:503:EDES.PROC PP")
    field(LNK2, "YCOR:LI27:503:EACT.PROC PP")
    field(LNK3, "YCOR:LI27:503:EERR.DISA PP")
    field(LNK4, "YCOR:LI27:503:ECON.PROC PP")
    field(LNK5, "YCOR:LI27:503:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI27:503:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI27:503:BLEM.PROC PP")
    field(LNK8, "YCOR:LI27:503:BMOD.PROC PP")
    field(LNK9, "YCOR:LI27:503:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI27:503:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI27:503:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI27:503:BMAX")
  field(DOL2, "YCOR:LI27:503:BMAX")
  field(DOL3, "YCOR:LI27:503:BMAX")
  field(DOL4, "YCOR:LI27:503:BMIN")
  field(DOL5, "YCOR:LI27:503:BMIN")
  field(DOL6, "YCOR:LI27:503:BMIN")
  field(LNK1, "YCOR:LI27:503:BMAGX.HOPR")
  field(LNK2, "YCOR:LI27:503:BMAGY.HOPR")
  field(LNK3, "YCOR:LI27:503:BLEM.HOPR")
  field(LNK4, "YCOR:LI27:503:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI27:503:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI27:503:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:503:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:503:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI27:503:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI27:503:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI27:503:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:503:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:503:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:503:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:503:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:503:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI27:503:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI27:503:EDES NPP MS")
  field(INPB, "YCOR:LI27:503:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI27:603:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI27:603:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI27:603:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI27:603:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI27:603:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI27:603:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI27:603:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI27:603:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI27:603:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI27:603:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI27:603:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI27:603:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI27:603:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI27:603:EDES.PROC PP")
    field(LNK2, "YCOR:LI27:603:EACT.PROC PP")
    field(LNK3, "YCOR:LI27:603:EERR.DISA PP")
    field(LNK4, "YCOR:LI27:603:ECON.PROC PP")
    field(LNK5, "YCOR:LI27:603:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI27:603:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI27:603:BLEM.PROC PP")
    field(LNK8, "YCOR:LI27:603:BMOD.PROC PP")
    field(LNK9, "YCOR:LI27:603:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI27:603:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI27:603:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI27:603:BMAX")
  field(DOL2, "YCOR:LI27:603:BMAX")
  field(DOL3, "YCOR:LI27:603:BMAX")
  field(DOL4, "YCOR:LI27:603:BMIN")
  field(DOL5, "YCOR:LI27:603:BMIN")
  field(DOL6, "YCOR:LI27:603:BMIN")
  field(LNK1, "YCOR:LI27:603:BMAGX.HOPR")
  field(LNK2, "YCOR:LI27:603:BMAGY.HOPR")
  field(LNK3, "YCOR:LI27:603:BLEM.HOPR")
  field(LNK4, "YCOR:LI27:603:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI27:603:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI27:603:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:603:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:603:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI27:603:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI27:603:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI27:603:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:603:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:603:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:603:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:603:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:603:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI27:603:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI27:603:EDES NPP MS")
  field(INPB, "YCOR:LI27:603:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI27:703:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI27:703:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI27:703:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI27:703:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI27:703:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI27:703:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI27:703:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI27:703:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI27:703:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI27:703:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI27:703:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI27:703:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI27:703:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI27:703:EDES.PROC PP")
    field(LNK2, "YCOR:LI27:703:EACT.PROC PP")
    field(LNK3, "YCOR:LI27:703:EERR.DISA PP")
    field(LNK4, "YCOR:LI27:703:ECON.PROC PP")
    field(LNK5, "YCOR:LI27:703:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI27:703:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI27:703:BLEM.PROC PP")
    field(LNK8, "YCOR:LI27:703:BMOD.PROC PP")
    field(LNK9, "YCOR:LI27:703:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI27:703:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI27:703:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI27:703:BMAX")
  field(DOL2, "YCOR:LI27:703:BMAX")
  field(DOL3, "YCOR:LI27:703:BMAX")
  field(DOL4, "YCOR:LI27:703:BMIN")
  field(DOL5, "YCOR:LI27:703:BMIN")
  field(DOL6, "YCOR:LI27:703:BMIN")
  field(LNK1, "YCOR:LI27:703:BMAGX.HOPR")
  field(LNK2, "YCOR:LI27:703:BMAGY.HOPR")
  field(LNK3, "YCOR:LI27:703:BLEM.HOPR")
  field(LNK4, "YCOR:LI27:703:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI27:703:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI27:703:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:703:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:703:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI27:703:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI27:703:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI27:703:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:703:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:703:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:703:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:703:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:703:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI27:703:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI27:703:EDES NPP MS")
  field(INPB, "YCOR:LI27:703:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI27:803:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI27:803:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI27:803:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI27:803:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI27:803:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI27:803:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI27:803:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI27:803:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI27:803:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI27:803:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI27:803:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI27:803:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI27:803:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI27:803:EDES.PROC PP")
    field(LNK2, "YCOR:LI27:803:EACT.PROC PP")
    field(LNK3, "YCOR:LI27:803:EERR.DISA PP")
    field(LNK4, "YCOR:LI27:803:ECON.PROC PP")
    field(LNK5, "YCOR:LI27:803:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI27:803:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI27:803:BLEM.PROC PP")
    field(LNK8, "YCOR:LI27:803:BMOD.PROC PP")
    field(LNK9, "YCOR:LI27:803:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI27:803:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI27:803:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI27:803:BMAX")
  field(DOL2, "YCOR:LI27:803:BMAX")
  field(DOL3, "YCOR:LI27:803:BMAX")
  field(DOL4, "YCOR:LI27:803:BMIN")
  field(DOL5, "YCOR:LI27:803:BMIN")
  field(DOL6, "YCOR:LI27:803:BMIN")
  field(LNK1, "YCOR:LI27:803:BMAGX.HOPR")
  field(LNK2, "YCOR:LI27:803:BMAGY.HOPR")
  field(LNK3, "YCOR:LI27:803:BLEM.HOPR")
  field(LNK4, "YCOR:LI27:803:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI27:803:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI27:803:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:803:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:803:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI27:803:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI27:803:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI27:803:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:803:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:803:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:803:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:803:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:803:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI27:803:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI27:803:EDES NPP MS")
  field(INPB, "YCOR:LI27:803:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI27:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI27:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI27:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI27:900:FUNC CA PP")
  field(DOL2, "MGNT:LI27:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI27:900:FUNC CA PP")
  field(DOL3, "MGNT:LI27:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI27:900:FUNC CA PP")
  field(DOL4, "MGNT:LI27:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI27:900:FUNC CA PP")
  field(DOL5, "MGNT:LI27:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI27:900:FUNC CA PP")
  field(DOL6, "MGNT:LI27:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI27:900:FUNC CA PP")
  field(DOL7, "MGNT:LI27:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI27:900:FUNC CA PP")
  field(DOL8, "MGNT:LI27:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI27:900:FUNC CA PP")
  field(DOL9, "MGNT:LI27:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI27:900:FUNC CA PP")
  field(DOLA, "MGNT:LI27:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI27:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI27:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI27:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI27:900:EDES.PROC PP")
    field(LNK2, "YCOR:LI27:900:EACT.PROC PP")
    field(LNK3, "YCOR:LI27:900:EERR.DISA PP")
    field(LNK4, "YCOR:LI27:900:ECON.PROC PP")
    field(LNK5, "YCOR:LI27:900:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI27:900:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI27:900:BLEM.PROC PP")
    field(LNK8, "YCOR:LI27:900:BMOD.PROC PP")
    field(LNK9, "YCOR:LI27:900:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI27:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI27:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI27:900:BMAX")
  field(DOL2, "YCOR:LI27:900:BMAX")
  field(DOL3, "YCOR:LI27:900:BMAX")
  field(DOL4, "YCOR:LI27:900:BMIN")
  field(DOL5, "YCOR:LI27:900:BMIN")
  field(DOL6, "YCOR:LI27:900:BMIN")
  field(LNK1, "YCOR:LI27:900:BMAGX.HOPR")
  field(LNK2, "YCOR:LI27:900:BMAGY.HOPR")
  field(LNK3, "YCOR:LI27:900:BLEM.HOPR")
  field(LNK4, "YCOR:LI27:900:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI27:900:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI27:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI27:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI27:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI27:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI27:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI27:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI27:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI27:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI27:900:EDES NPP MS")
  field(INPB, "YCOR:LI27:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:LI28:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:LI28:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:LI28:1:CTRL CA PP")
  field(LNK2, "MGNT:LI28:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:LI28:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:LI28:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:LI28:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:LI28:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:LI28:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:LI28:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:LI28:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:LI28:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:LI28:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:LI28:1:ALLSWITCH")
}

record(seq, "MGNT:LI28:1:ALLSWITCH") {
  field(DOL1, "MGNT:LI28:1:CTRL.FFVL")
  field(LNK1, "MGNT:LI28:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI28:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI28:1:CTRL")
}

record(bo, "MGNT:LI28:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:LI28:1:ALLSTARGO")
}

record(fanout, "MGNT:LI28:1:ALLSTARGO") {
  field(LNK1, "MGNT:LI28:1:ALLBENDSGO")
  field(LNK2, "MGNT:LI28:1:ALLBTRMSGO")
  field(LNK3, "MGNT:LI28:1:ALLLGPSSGO")
  field(LNK4, "MGNT:LI28:1:ALLQUADSGO")
  field(LNK5, "MGNT:LI28:1:ALLXCORSGO")
  field(LNK6, "MGNT:LI28:1:ALLYCORSGO")
  field(FLNK, "MGNT:LI28:1:ALLSTARGO_2")
}
record(fanout, "MGNT:LI28:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:LI28:1:ALLSOLNSGO")
  field(LNK2, "MGNT:LI28:1:ALLKICKSGO")
  field(LNK3, "MGNT:LI28:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:LI28:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:LI28:1:BENDSWITCH")
}

record(seq, "MGNT:LI28:1:BENDSWITCH") {
  field(DOL1, "MGNT:LI28:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:LI28:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI28:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI28:1:BENDCTRL")
}

record(seq, "MGNT:LI28:1:ALLBENDSGO") {
  field(DOL1, "MGNT:LI28:1:ALLSTAR")
  field(LNK1, "MGNT:LI28:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:LI28:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI28:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI28:1:BENDCTRL",20,10,0,0,"MGNT:LI28:1:BENDCTRL")
#! Field("MGNT:LI28:1:BENDCTRL.FLNK",16777215,1,"MGNT:LI28:1:BENDCTRL.FLNK")
#! Link("MGNT:LI28:1:BENDCTRL.FLNK","MGNT:LI28:1:BENDSWITCH")
#! Field("MGNT:LI28:1:BENDCTRL.FFVL",16777215,1,"MGNT:LI28:1:BENDCTRL.FFVL")
#! Record("MGNT:LI28:1:BENDSWITCH",460,322,0,0,"MGNT:LI28:1:BENDSWITCH")
#! Field("MGNT:LI28:1:BENDSWITCH.DOL1",16777215,0,"MGNT:LI28:1:BENDSWITCH.DOL1")
#! Link("MGNT:LI28:1:BENDSWITCH.DOL1","MGNT:LI28:1:BENDCTRL.FFVL")
#! Field("MGNT:LI28:1:BENDSWITCH.LNK1",16777215,1,"MGNT:LI28:1:BENDSWITCH.LNK1")
#! Field("MGNT:LI28:1:BENDSWITCH.FLNK",16777215,1,"MGNT:LI28:1:BENDSWITCH.FLNK")
#! Record("MGNT:LI28:1:ALLBENDSGO",240,96,0,0,"MGNT:LI28:1:ALLBENDSGO")
#! Field("MGNT:LI28:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:LI28:1:ALLBENDSGO.DOL1")
#! Field("MGNT:LI28:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:LI28:1:ALLBENDSGO.LNK1")
#! Link("MGNT:LI28:1:ALLBENDSGO.LNK1","MGNT:LI28:1:ALLBENDS.VAL")
#! Record("MGNT:LI28:1:ALLBENDS",540,102,0,0,"MGNT:LI28:1:ALLBENDS")
#! Field("MGNT:LI28:1:ALLBENDS.VAL",16777215,0,"MGNT:LI28:1:ALLBENDS.VAL")
#! Field("MGNT:LI28:1:ALLBENDS.FLNK",16777215,1,"MGNT:LI28:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:LI28:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI28:1:BTRMSWITCH")
}

record(seq, "MGNT:LI28:1:BTRMSWITCH") {
  field(DOL1, "MGNT:LI28:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:LI28:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI28:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI28:1:BTRMCTRL")
}

record(seq, "MGNT:LI28:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:LI28:1:ALLSTAR")
  field(LNK1, "MGNT:LI28:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:LI28:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI28:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI28:1:BTRMCTRL",20,10,0,0,"MGNT:LI28:1:BTRMCTRL")
#! Field("MGNT:LI28:1:BTRMCTRL.FLNK",16777215,1,"MGNT:LI28:1:BTRMCTRL.FLNK")
#! Link("MGNT:LI28:1:BTRMCTRL.FLNK","MGNT:LI28:1:BTRMSWITCH")
#! Field("MGNT:LI28:1:BTRMCTRL.FFVL",16777215,1,"MGNT:LI28:1:BTRMCTRL.FFVL")
#! Record("MGNT:LI28:1:BTRMSWITCH",460,322,0,0,"MGNT:LI28:1:BTRMSWITCH")
#! Field("MGNT:LI28:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:LI28:1:BTRMSWITCH.DOL1")
#! Link("MGNT:LI28:1:BTRMSWITCH.DOL1","MGNT:LI28:1:BTRMCTRL.FFVL")
#! Field("MGNT:LI28:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:LI28:1:BTRMSWITCH.LNK1")
#! Field("MGNT:LI28:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:LI28:1:BTRMSWITCH.FLNK")
#! Record("MGNT:LI28:1:ALLBTRMSGO",240,96,0,0,"MGNT:LI28:1:ALLBTRMSGO")
#! Field("MGNT:LI28:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:LI28:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:LI28:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:LI28:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:LI28:1:ALLBTRMSGO.LNK1","MGNT:LI28:1:ALLBTRMS.VAL")
#! Record("MGNT:LI28:1:ALLBTRMS",540,102,0,0,"MGNT:LI28:1:ALLBTRMS")
#! Field("MGNT:LI28:1:ALLBTRMS.VAL",16777215,0,"MGNT:LI28:1:ALLBTRMS.VAL")
#! Field("MGNT:LI28:1:ALLBTRMS.FLNK",16777215,1,"MGNT:LI28:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:LI28:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI28:1:LGPSSWITCH")
}

record(seq, "MGNT:LI28:1:LGPSSWITCH") {
  field(DOL1, "MGNT:LI28:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:LI28:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI28:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI28:1:LGPSCTRL")
}

record(seq, "MGNT:LI28:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:LI28:1:ALLSTAR")
  field(LNK1, "MGNT:LI28:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:LI28:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI28:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI28:1:LGPSCTRL",20,10,0,0,"MGNT:LI28:1:LGPSCTRL")
#! Field("MGNT:LI28:1:LGPSCTRL.FLNK",16777215,1,"MGNT:LI28:1:LGPSCTRL.FLNK")
#! Link("MGNT:LI28:1:LGPSCTRL.FLNK","MGNT:LI28:1:LGPSSWITCH")
#! Field("MGNT:LI28:1:LGPSCTRL.FFVL",16777215,1,"MGNT:LI28:1:LGPSCTRL.FFVL")
#! Record("MGNT:LI28:1:LGPSSWITCH",460,322,0,0,"MGNT:LI28:1:LGPSSWITCH")
#! Field("MGNT:LI28:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:LI28:1:LGPSSWITCH.DOL1")
#! Link("MGNT:LI28:1:LGPSSWITCH.DOL1","MGNT:LI28:1:LGPSCTRL.FFVL")
#! Field("MGNT:LI28:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:LI28:1:LGPSSWITCH.LNK1")
#! Field("MGNT:LI28:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:LI28:1:LGPSSWITCH.FLNK")
#! Record("MGNT:LI28:1:ALLLGPSSGO",240,96,0,0,"MGNT:LI28:1:ALLLGPSSGO")
#! Field("MGNT:LI28:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:LI28:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:LI28:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:LI28:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:LI28:1:ALLLGPSSGO.LNK1","MGNT:LI28:1:ALLLGPSS.VAL")
#! Record("MGNT:LI28:1:ALLLGPSS",540,102,0,0,"MGNT:LI28:1:ALLLGPSS")
#! Field("MGNT:LI28:1:ALLLGPSS.VAL",16777215,0,"MGNT:LI28:1:ALLLGPSS.VAL")
#! Field("MGNT:LI28:1:ALLLGPSS.FLNK",16777215,1,"MGNT:LI28:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:LI28:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:LI28:1:QUADSWITCH")
}

record(seq, "MGNT:LI28:1:QUADSWITCH") {
  field(DOL1, "MGNT:LI28:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:LI28:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI28:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI28:1:QUADCTRL")
}

record(seq, "MGNT:LI28:1:ALLQUADSGO") {
  field(DOL1, "MGNT:LI28:1:ALLSTAR")
  field(LNK1, "MGNT:LI28:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:LI28:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI28:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI28:1:QUADCTRL",20,10,0,0,"MGNT:LI28:1:QUADCTRL")
#! Field("MGNT:LI28:1:QUADCTRL.FLNK",16777215,1,"MGNT:LI28:1:QUADCTRL.FLNK")
#! Link("MGNT:LI28:1:QUADCTRL.FLNK","MGNT:LI28:1:QUADSWITCH")
#! Field("MGNT:LI28:1:QUADCTRL.FFVL",16777215,1,"MGNT:LI28:1:QUADCTRL.FFVL")
#! Record("MGNT:LI28:1:QUADSWITCH",460,322,0,0,"MGNT:LI28:1:QUADSWITCH")
#! Field("MGNT:LI28:1:QUADSWITCH.DOL1",16777215,0,"MGNT:LI28:1:QUADSWITCH.DOL1")
#! Link("MGNT:LI28:1:QUADSWITCH.DOL1","MGNT:LI28:1:QUADCTRL.FFVL")
#! Field("MGNT:LI28:1:QUADSWITCH.LNK1",16777215,1,"MGNT:LI28:1:QUADSWITCH.LNK1")
#! Field("MGNT:LI28:1:QUADSWITCH.FLNK",16777215,1,"MGNT:LI28:1:QUADSWITCH.FLNK")
#! Record("MGNT:LI28:1:ALLQUADSGO",240,96,0,0,"MGNT:LI28:1:ALLQUADSGO")
#! Field("MGNT:LI28:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:LI28:1:ALLQUADSGO.DOL1")
#! Field("MGNT:LI28:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:LI28:1:ALLQUADSGO.LNK1")
#! Link("MGNT:LI28:1:ALLQUADSGO.LNK1","MGNT:LI28:1:ALLQUADS.VAL")
#! Record("MGNT:LI28:1:ALLQUADS",540,102,0,0,"MGNT:LI28:1:ALLQUADS")
#! Field("MGNT:LI28:1:ALLQUADS.VAL",16777215,0,"MGNT:LI28:1:ALLQUADS.VAL")
#! Field("MGNT:LI28:1:ALLQUADS.FLNK",16777215,1,"MGNT:LI28:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:LI28:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:LI28:1:XCORSWITCH")
}

record(seq, "MGNT:LI28:1:XCORSWITCH") {
  field(DOL1, "MGNT:LI28:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:LI28:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI28:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI28:1:XCORCTRL")
}

record(seq, "MGNT:LI28:1:ALLXCORSGO") {
  field(DOL1, "MGNT:LI28:1:ALLSTAR")
  field(LNK1, "MGNT:LI28:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:LI28:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI28:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI28:1:XCORCTRL",20,10,0,0,"MGNT:LI28:1:XCORCTRL")
#! Field("MGNT:LI28:1:XCORCTRL.FLNK",16777215,1,"MGNT:LI28:1:XCORCTRL.FLNK")
#! Link("MGNT:LI28:1:XCORCTRL.FLNK","MGNT:LI28:1:XCORSWITCH")
#! Field("MGNT:LI28:1:XCORCTRL.FFVL",16777215,1,"MGNT:LI28:1:XCORCTRL.FFVL")
#! Record("MGNT:LI28:1:XCORSWITCH",460,322,0,0,"MGNT:LI28:1:XCORSWITCH")
#! Field("MGNT:LI28:1:XCORSWITCH.DOL1",16777215,0,"MGNT:LI28:1:XCORSWITCH.DOL1")
#! Link("MGNT:LI28:1:XCORSWITCH.DOL1","MGNT:LI28:1:XCORCTRL.FFVL")
#! Field("MGNT:LI28:1:XCORSWITCH.LNK1",16777215,1,"MGNT:LI28:1:XCORSWITCH.LNK1")
#! Field("MGNT:LI28:1:XCORSWITCH.FLNK",16777215,1,"MGNT:LI28:1:XCORSWITCH.FLNK")
#! Record("MGNT:LI28:1:ALLXCORSGO",240,96,0,0,"MGNT:LI28:1:ALLXCORSGO")
#! Field("MGNT:LI28:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:LI28:1:ALLXCORSGO.DOL1")
#! Field("MGNT:LI28:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:LI28:1:ALLXCORSGO.LNK1")
#! Link("MGNT:LI28:1:ALLXCORSGO.LNK1","MGNT:LI28:1:ALLXCORS.VAL")
#! Record("MGNT:LI28:1:ALLXCORS",540,102,0,0,"MGNT:LI28:1:ALLXCORS")
#! Field("MGNT:LI28:1:ALLXCORS.VAL",16777215,0,"MGNT:LI28:1:ALLXCORS.VAL")
#! Field("MGNT:LI28:1:ALLXCORS.FLNK",16777215,1,"MGNT:LI28:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:LI28:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:LI28:1:YCORSWITCH")
}

record(seq, "MGNT:LI28:1:YCORSWITCH") {
  field(DOL1, "MGNT:LI28:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:LI28:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI28:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI28:1:YCORCTRL")
}

record(seq, "MGNT:LI28:1:ALLYCORSGO") {
  field(DOL1, "MGNT:LI28:1:ALLSTAR")
  field(LNK1, "MGNT:LI28:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:LI28:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI28:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI28:1:YCORCTRL",20,10,0,0,"MGNT:LI28:1:YCORCTRL")
#! Field("MGNT:LI28:1:YCORCTRL.FLNK",16777215,1,"MGNT:LI28:1:YCORCTRL.FLNK")
#! Link("MGNT:LI28:1:YCORCTRL.FLNK","MGNT:LI28:1:YCORSWITCH")
#! Field("MGNT:LI28:1:YCORCTRL.FFVL",16777215,1,"MGNT:LI28:1:YCORCTRL.FFVL")
#! Record("MGNT:LI28:1:YCORSWITCH",460,322,0,0,"MGNT:LI28:1:YCORSWITCH")
#! Field("MGNT:LI28:1:YCORSWITCH.DOL1",16777215,0,"MGNT:LI28:1:YCORSWITCH.DOL1")
#! Link("MGNT:LI28:1:YCORSWITCH.DOL1","MGNT:LI28:1:YCORCTRL.FFVL")
#! Field("MGNT:LI28:1:YCORSWITCH.LNK1",16777215,1,"MGNT:LI28:1:YCORSWITCH.LNK1")
#! Field("MGNT:LI28:1:YCORSWITCH.FLNK",16777215,1,"MGNT:LI28:1:YCORSWITCH.FLNK")
#! Record("MGNT:LI28:1:ALLYCORSGO",240,96,0,0,"MGNT:LI28:1:ALLYCORSGO")
#! Field("MGNT:LI28:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:LI28:1:ALLYCORSGO.DOL1")
#! Field("MGNT:LI28:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:LI28:1:ALLYCORSGO.LNK1")
#! Link("MGNT:LI28:1:ALLYCORSGO.LNK1","MGNT:LI28:1:ALLYCORS.VAL")
#! Record("MGNT:LI28:1:ALLYCORS",540,102,0,0,"MGNT:LI28:1:ALLYCORS")
#! Field("MGNT:LI28:1:ALLYCORS.VAL",16777215,0,"MGNT:LI28:1:ALLYCORS.VAL")
#! Field("MGNT:LI28:1:ALLYCORS.FLNK",16777215,1,"MGNT:LI28:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:LI28:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:LI28:1:SOLNSWITCH")
}

record(seq, "MGNT:LI28:1:SOLNSWITCH") {
  field(DOL1, "MGNT:LI28:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:LI28:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI28:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI28:1:SOLNCTRL")
}

record(seq, "MGNT:LI28:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:LI28:1:ALLSTAR")
  field(LNK1, "MGNT:LI28:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:LI28:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI28:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI28:1:SOLNCTRL",20,10,0,0,"MGNT:LI28:1:SOLNCTRL")
#! Field("MGNT:LI28:1:SOLNCTRL.FLNK",16777215,1,"MGNT:LI28:1:SOLNCTRL.FLNK")
#! Link("MGNT:LI28:1:SOLNCTRL.FLNK","MGNT:LI28:1:SOLNSWITCH")
#! Field("MGNT:LI28:1:SOLNCTRL.FFVL",16777215,1,"MGNT:LI28:1:SOLNCTRL.FFVL")
#! Record("MGNT:LI28:1:SOLNSWITCH",460,322,0,0,"MGNT:LI28:1:SOLNSWITCH")
#! Field("MGNT:LI28:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:LI28:1:SOLNSWITCH.DOL1")
#! Link("MGNT:LI28:1:SOLNSWITCH.DOL1","MGNT:LI28:1:SOLNCTRL.FFVL")
#! Field("MGNT:LI28:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:LI28:1:SOLNSWITCH.LNK1")
#! Field("MGNT:LI28:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:LI28:1:SOLNSWITCH.FLNK")
#! Record("MGNT:LI28:1:ALLSOLNSGO",240,96,0,0,"MGNT:LI28:1:ALLSOLNSGO")
#! Field("MGNT:LI28:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:LI28:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:LI28:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:LI28:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:LI28:1:ALLSOLNSGO.LNK1","MGNT:LI28:1:ALLSOLNS.VAL")
#! Record("MGNT:LI28:1:ALLSOLNS",540,102,0,0,"MGNT:LI28:1:ALLSOLNS")
#! Field("MGNT:LI28:1:ALLSOLNS.VAL",16777215,0,"MGNT:LI28:1:ALLSOLNS.VAL")
#! Field("MGNT:LI28:1:ALLSOLNS.FLNK",16777215,1,"MGNT:LI28:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:LI28:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:LI28:1:KICKSWITCH")
}

record(seq, "MGNT:LI28:1:KICKSWITCH") {
  field(DOL1, "MGNT:LI28:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:LI28:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI28:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI28:1:KICKCTRL")
}

record(seq, "MGNT:LI28:1:ALLKICKSGO") {
  field(DOL1, "MGNT:LI28:1:ALLSTAR")
  field(LNK1, "MGNT:LI28:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:LI28:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI28:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI28:1:KICKCTRL",20,10,0,0,"MGNT:LI28:1:KICKCTRL")
#! Field("MGNT:LI28:1:KICKCTRL.FLNK",16777215,1,"MGNT:LI28:1:KICKCTRL.FLNK")
#! Link("MGNT:LI28:1:KICKCTRL.FLNK","MGNT:LI28:1:KICKSWITCH")
#! Field("MGNT:LI28:1:KICKCTRL.FFVL",16777215,1,"MGNT:LI28:1:KICKCTRL.FFVL")
#! Record("MGNT:LI28:1:KICKSWITCH",460,322,0,0,"MGNT:LI28:1:KICKSWITCH")
#! Field("MGNT:LI28:1:KICKSWITCH.DOL1",16777215,0,"MGNT:LI28:1:KICKSWITCH.DOL1")
#! Link("MGNT:LI28:1:KICKSWITCH.DOL1","MGNT:LI28:1:KICKCTRL.FFVL")
#! Field("MGNT:LI28:1:KICKSWITCH.LNK1",16777215,1,"MGNT:LI28:1:KICKSWITCH.LNK1")
#! Field("MGNT:LI28:1:KICKSWITCH.FLNK",16777215,1,"MGNT:LI28:1:KICKSWITCH.FLNK")
#! Record("MGNT:LI28:1:ALLKICKSGO",240,96,0,0,"MGNT:LI28:1:ALLKICKSGO")
#! Field("MGNT:LI28:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:LI28:1:ALLKICKSGO.DOL1")
#! Field("MGNT:LI28:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:LI28:1:ALLKICKSGO.LNK1")
#! Link("MGNT:LI28:1:ALLKICKSGO.LNK1","MGNT:LI28:1:ALLKICKS.VAL")
#! Record("MGNT:LI28:1:ALLKICKS",540,102,0,0,"MGNT:LI28:1:ALLKICKS")
#! Field("MGNT:LI28:1:ALLKICKS.VAL",16777215,0,"MGNT:LI28:1:ALLKICKS.VAL")
#! Field("MGNT:LI28:1:ALLKICKS.FLNK",16777215,1,"MGNT:LI28:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:LI28:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:LI28:1:SEXTSWITCH")
}

record(seq, "MGNT:LI28:1:SEXTSWITCH") {
  field(DOL1, "MGNT:LI28:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:LI28:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI28:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI28:1:SEXTCTRL")
}

record(seq, "MGNT:LI28:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:LI28:1:ALLSTAR")
  field(LNK1, "MGNT:LI28:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:LI28:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI28:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI28:1:SEXTCTRL",20,10,0,0,"MGNT:LI28:1:SEXTCTRL")
#! Field("MGNT:LI28:1:SEXTCTRL.FLNK",16777215,1,"MGNT:LI28:1:SEXTCTRL.FLNK")
#! Link("MGNT:LI28:1:SEXTCTRL.FLNK","MGNT:LI28:1:SEXTSWITCH")
#! Field("MGNT:LI28:1:SEXTCTRL.FFVL",16777215,1,"MGNT:LI28:1:SEXTCTRL.FFVL")
#! Record("MGNT:LI28:1:SEXTSWITCH",460,322,0,0,"MGNT:LI28:1:SEXTSWITCH")
#! Field("MGNT:LI28:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:LI28:1:SEXTSWITCH.DOL1")
#! Link("MGNT:LI28:1:SEXTSWITCH.DOL1","MGNT:LI28:1:SEXTCTRL.FFVL")
#! Field("MGNT:LI28:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:LI28:1:SEXTSWITCH.LNK1")
#! Field("MGNT:LI28:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:LI28:1:SEXTSWITCH.FLNK")
#! Record("MGNT:LI28:1:ALLSEXTSGO",240,96,0,0,"MGNT:LI28:1:ALLSEXTSGO")
#! Field("MGNT:LI28:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:LI28:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:LI28:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:LI28:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:LI28:1:ALLSEXTSGO.LNK1","MGNT:LI28:1:ALLSEXTS.VAL")
#! Record("MGNT:LI28:1:ALLSEXTS",540,102,0,0,"MGNT:LI28:1:ALLSEXTS")
#! Field("MGNT:LI28:1:ALLSEXTS.VAL",16777215,0,"MGNT:LI28:1:ALLSEXTS.VAL")
#! Field("MGNT:LI28:1:ALLSEXTS.FLNK",16777215,1,"MGNT:LI28:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record (seq, "MGNT:LI28:1:ALLBENDSSEL"){
}
record (seq, "MGNT:LI28:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:LI28:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:LI28:1:ALLKICKSSEL"){
}
record (seq, "MGNT:LI28:1:ALLSEXTSSEL"){
}

record (seq, "MGNT:LI28:1:ALLLGPSSSEL"){
  field (DOL1, "MGNT:LI28:1:ALLLGPSS")
  field (LNK1, "LGPS:LI28:2:SELECT CPP NMS")
}

record (seq, "MGNT:LI28:1:ALLQUADSSEL"){
  field (DOL1, "MGNT:LI28:1:ALLQUADS")
  field (DOL2, "MGNT:LI28:1:ALLQUADS")
  field (DOL3, "MGNT:LI28:1:ALLQUADS")
  field (DOL4, "MGNT:LI28:1:ALLQUADS")
  field (DOL5, "MGNT:LI28:1:ALLQUADS")
  field (DOL6, "MGNT:LI28:1:ALLQUADS")
  field (DOL7, "MGNT:LI28:1:ALLQUADS")
  field (DOL8, "MGNT:LI28:1:ALLQUADS")
  field (LNK1, "QUAD:LI28:201:SELECT CPP NMS")
  field (LNK2, "QUAD:LI28:301:SELECT CPP NMS")
  field (LNK3, "QUAD:LI28:401:SELECT CPP NMS")
  field (LNK4, "QUAD:LI28:501:SELECT CPP NMS")
  field (LNK5, "QUAD:LI28:601:SELECT CPP NMS")
  field (LNK6, "QUAD:LI28:701:SELECT CPP NMS")
  field (LNK7, "QUAD:LI28:801:SELECT CPP NMS")
  field (LNK8, "QUAD:LI28:901:SELECT CPP NMS")
}

record (seq, "MGNT:LI28:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:LI28:1:ALLXCORS")
  field (DOL2, "MGNT:LI28:1:ALLXCORS")
  field (DOL3, "MGNT:LI28:1:ALLXCORS")
  field (DOL4, "MGNT:LI28:1:ALLXCORS")
  field (DOL5, "MGNT:LI28:1:ALLXCORS")
  field (DOL6, "MGNT:LI28:1:ALLXCORS")
  field (DOL7, "MGNT:LI28:1:ALLXCORS")
  field (DOL8, "MGNT:LI28:1:ALLXCORS")
  field (LNK1, "XCOR:LI28:202:SELECT CPP NMS")
  field (LNK2, "XCOR:LI28:302:SELECT CPP NMS")
  field (LNK3, "XCOR:LI28:402:SELECT CPP NMS")
  field (LNK4, "XCOR:LI28:502:SELECT CPP NMS")
  field (LNK5, "XCOR:LI28:602:SELECT CPP NMS")
  field (LNK6, "XCOR:LI28:702:SELECT CPP NMS")
  field (LNK7, "XCOR:LI28:802:SELECT CPP NMS")
  field (LNK8, "XCOR:LI28:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI28:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:LI28:1:ALLYCORS")
  field (DOL2, "MGNT:LI28:1:ALLYCORS")
  field (DOL3, "MGNT:LI28:1:ALLYCORS")
  field (DOL4, "MGNT:LI28:1:ALLYCORS")
  field (DOL5, "MGNT:LI28:1:ALLYCORS")
  field (DOL6, "MGNT:LI28:1:ALLYCORS")
  field (DOL7, "MGNT:LI28:1:ALLYCORS")
  field (DOL8, "MGNT:LI28:1:ALLYCORS")
  field (LNK1, "YCOR:LI28:203:SELECT CPP NMS")
  field (LNK2, "YCOR:LI28:303:SELECT CPP NMS")
  field (LNK3, "YCOR:LI28:403:SELECT CPP NMS")
  field (LNK4, "YCOR:LI28:503:SELECT CPP NMS")
  field (LNK5, "YCOR:LI28:603:SELECT CPP NMS")
  field (LNK6, "YCOR:LI28:703:SELECT CPP NMS")
  field (LNK7, "YCOR:LI28:803:SELECT CPP NMS")
  field (LNK8, "YCOR:LI28:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI28:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (LNK1, "MGNT:LI28:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:LI28:1:QUADFUNCGO.PROC")
  field (LNK3, "MGNT:LI28:1:XCORFUNCGO.PROC")
  field (LNK4, "MGNT:LI28:1:YCORFUNCGO.PROC")
  field (LNK5, "MGNT:LI28:1:LGPSFUNCGO.PROC")
  field (LNK6, "MGNT:LI28:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:LI28:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI28:1:QUADFUNCGO") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI28:201:ALLFUNCGO")
  field (LNK2, "QUAD:LI28:301:ALLFUNCGO")
  field (LNK3, "QUAD:LI28:401:ALLFUNCGO")
  field (LNK4, "QUAD:LI28:501:ALLFUNCGO")
  field (LNK5, "QUAD:LI28:601:ALLFUNCGO")
  field (LNK6, "QUAD:LI28:701:ALLFUNCGO")
  field (FLNK, "MGNT:LI28:1:QUADFUNCGO1")
}

record (fanout, "MGNT:LI28:1:QUADFUNCGO1") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI28:801:ALLFUNCGO")
  field (LNK2, "QUAD:LI28:901:ALLFUNCGO")
  field (FLNK, "MGNT:LI28:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI28:1:XCORFUNCGO") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI28:202:ALLFUNCGO")
  field (LNK2, "XCOR:LI28:302:ALLFUNCGO")
  field (LNK3, "XCOR:LI28:402:ALLFUNCGO")
  field (LNK4, "XCOR:LI28:502:ALLFUNCGO")
  field (LNK5, "XCOR:LI28:602:ALLFUNCGO")
  field (LNK6, "XCOR:LI28:702:ALLFUNCGO")
  field (FLNK, "MGNT:LI28:1:XCORFUNCGO1")
}

record (fanout, "MGNT:LI28:1:XCORFUNCGO1") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI28:802:ALLFUNCGO")
  field (LNK2, "XCOR:LI28:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI28:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI28:1:YCORFUNCGO") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI28:203:ALLFUNCGO")
  field (LNK2, "YCOR:LI28:303:ALLFUNCGO")
  field (LNK3, "YCOR:LI28:403:ALLFUNCGO")
  field (LNK4, "YCOR:LI28:503:ALLFUNCGO")
  field (LNK5, "YCOR:LI28:603:ALLFUNCGO")
  field (LNK6, "YCOR:LI28:703:ALLFUNCGO")
  field (FLNK, "MGNT:LI28:1:YCORFUNCGO1")
}

record (fanout, "MGNT:LI28:1:YCORFUNCGO1") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI28:803:ALLFUNCGO")
  field (LNK2, "YCOR:LI28:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI28:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI28:1:LGPSFUNCGO"){
  field (DESC, "Process LGPS CTRL func")
  field (LNK1, "LGPS:LI28:2:ALLFUNCGO")
  field (FLNK, "MGNT:LI28:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI28:1:BENDFUNCGO"){
  field (DESC, "Process BEND CTRL func")
  field (FLNK, "MGNT:LI28:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI28:1:BTRMFUNCGO"){
  field (DESC, "Process BTRM CTRL func")
  field (FLNK, "MGNT:LI28:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI28:1:SOLNFUNCGO"){
  field (DESC, "Process SOLN CTRL func")
  field (FLNK, "MGNT:LI28:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI28:1:KICKFUNCGO"){
  field (DESC, "Process KICK CTRL func")
  field (FLNK, "MGNT:LI28:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI28:1:SEXTFUNCGO"){
  field (DESC, "Process SEXT CTRL func")
  field (FLNK, "MGNT:LI28:1:CTRLCLEAR")
}




#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LI28:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "LGPS:LI28:2:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LI28:2:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LI28:2:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LI28:2:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LI28:2:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LI28:2:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LI28:2:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LI28:2:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LI28:2:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LI28:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LI28:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LI28:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LI28:2:EDES.PROC PP")
    field(LNK2, "LGPS:LI28:2:EACT.PROC PP")
    field(LNK3, "LGPS:LI28:2:EERR.DISA PP")
    field(LNK4, "LGPS:LI28:2:ECON.PROC PP")
    field(LNK5, "LGPS:LI28:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:LI28:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:LI28:2:BLEM.PROC PP")
    field(LNK8, "LGPS:LI28:2:BMOD.PROC PP")
    field(LNK9, "LGPS:LI28:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LI28:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LI28:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LI28:2:BMAX")
  field(DOL2, "LGPS:LI28:2:BMAX")
  field(DOL3, "LGPS:LI28:2:BMAX")
  field(DOL4, "LGPS:LI28:2:BMIN")
  field(DOL5, "LGPS:LI28:2:BMIN")
  field(DOL6, "LGPS:LI28:2:BMIN")
  field(LNK1, "LGPS:LI28:2:BMAGX.HOPR")
  field(LNK2, "LGPS:LI28:2:BMAGY.HOPR")
  field(LNK3, "LGPS:LI28:2:BLEM.HOPR")
  field(LNK4, "LGPS:LI28:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LI28:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LI28:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LI28:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LI28:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LI28:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LI28:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LI28:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI28:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI28:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI28:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI28:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI28:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LI28:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LI28:2:EDES NPP MS")
  field(INPB, "LGPS:LI28:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI28:201:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI28:201:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI28:201:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI28:201:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI28:201:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI28:201:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI28:201:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI28:201:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI28:201:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI28:201:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI28:201:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI28:201:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI28:201:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI28:201:EDES.PROC PP")
    field(LNK2, "QUAD:LI28:201:EACT.PROC PP")
    field(LNK3, "QUAD:LI28:201:EERR.DISA PP")
    field(LNK4, "QUAD:LI28:201:ECON.PROC PP")
    field(LNK5, "QUAD:LI28:201:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI28:201:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI28:201:BLEM.PROC PP")
    field(LNK8, "QUAD:LI28:201:BMOD.PROC PP")
    field(LNK9, "QUAD:LI28:201:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI28:201:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI28:201:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI28:201:BMAX")
  field(DOL2, "QUAD:LI28:201:BMAX")
  field(DOL3, "QUAD:LI28:201:BMAX")
  field(DOL4, "QUAD:LI28:201:BMIN")
  field(DOL5, "QUAD:LI28:201:BMIN")
  field(DOL6, "QUAD:LI28:201:BMIN")
  field(LNK1, "QUAD:LI28:201:BMAGX.HOPR")
  field(LNK2, "QUAD:LI28:201:BMAGY.HOPR")
  field(LNK3, "QUAD:LI28:201:BLEM.HOPR")
  field(LNK4, "QUAD:LI28:201:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI28:201:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI28:201:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:201:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:201:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI28:201:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI28:201:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI28:201:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:201:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:201:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:201:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:201:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:201:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI28:201:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI28:201:EDES NPP MS")
  field(INPB, "QUAD:LI28:201:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI28:301:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI28:301:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI28:301:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI28:301:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI28:301:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI28:301:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI28:301:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI28:301:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI28:301:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI28:301:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI28:301:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI28:301:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI28:301:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI28:301:EDES.PROC PP")
    field(LNK2, "QUAD:LI28:301:EACT.PROC PP")
    field(LNK3, "QUAD:LI28:301:EERR.DISA PP")
    field(LNK4, "QUAD:LI28:301:ECON.PROC PP")
    field(LNK5, "QUAD:LI28:301:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI28:301:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI28:301:BLEM.PROC PP")
    field(LNK8, "QUAD:LI28:301:BMOD.PROC PP")
    field(LNK9, "QUAD:LI28:301:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI28:301:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI28:301:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI28:301:BMAX")
  field(DOL2, "QUAD:LI28:301:BMAX")
  field(DOL3, "QUAD:LI28:301:BMAX")
  field(DOL4, "QUAD:LI28:301:BMIN")
  field(DOL5, "QUAD:LI28:301:BMIN")
  field(DOL6, "QUAD:LI28:301:BMIN")
  field(LNK1, "QUAD:LI28:301:BMAGX.HOPR")
  field(LNK2, "QUAD:LI28:301:BMAGY.HOPR")
  field(LNK3, "QUAD:LI28:301:BLEM.HOPR")
  field(LNK4, "QUAD:LI28:301:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI28:301:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI28:301:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:301:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:301:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI28:301:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI28:301:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI28:301:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:301:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:301:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:301:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:301:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:301:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI28:301:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI28:301:EDES NPP MS")
  field(INPB, "QUAD:LI28:301:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI28:401:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI28:401:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI28:401:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI28:401:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI28:401:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI28:401:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI28:401:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI28:401:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI28:401:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI28:401:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI28:401:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI28:401:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI28:401:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI28:401:EDES.PROC PP")
    field(LNK2, "QUAD:LI28:401:EACT.PROC PP")
    field(LNK3, "QUAD:LI28:401:EERR.DISA PP")
    field(LNK4, "QUAD:LI28:401:ECON.PROC PP")
    field(LNK5, "QUAD:LI28:401:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI28:401:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI28:401:BLEM.PROC PP")
    field(LNK8, "QUAD:LI28:401:BMOD.PROC PP")
    field(LNK9, "QUAD:LI28:401:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI28:401:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI28:401:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI28:401:BMAX")
  field(DOL2, "QUAD:LI28:401:BMAX")
  field(DOL3, "QUAD:LI28:401:BMAX")
  field(DOL4, "QUAD:LI28:401:BMIN")
  field(DOL5, "QUAD:LI28:401:BMIN")
  field(DOL6, "QUAD:LI28:401:BMIN")
  field(LNK1, "QUAD:LI28:401:BMAGX.HOPR")
  field(LNK2, "QUAD:LI28:401:BMAGY.HOPR")
  field(LNK3, "QUAD:LI28:401:BLEM.HOPR")
  field(LNK4, "QUAD:LI28:401:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI28:401:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI28:401:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:401:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:401:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI28:401:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI28:401:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI28:401:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:401:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:401:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:401:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:401:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:401:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI28:401:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI28:401:EDES NPP MS")
  field(INPB, "QUAD:LI28:401:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI28:501:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI28:501:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI28:501:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI28:501:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI28:501:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI28:501:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI28:501:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI28:501:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI28:501:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI28:501:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI28:501:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI28:501:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI28:501:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI28:501:EDES.PROC PP")
    field(LNK2, "QUAD:LI28:501:EACT.PROC PP")
    field(LNK3, "QUAD:LI28:501:EERR.DISA PP")
    field(LNK4, "QUAD:LI28:501:ECON.PROC PP")
    field(LNK5, "QUAD:LI28:501:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI28:501:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI28:501:BLEM.PROC PP")
    field(LNK8, "QUAD:LI28:501:BMOD.PROC PP")
    field(LNK9, "QUAD:LI28:501:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI28:501:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI28:501:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI28:501:BMAX")
  field(DOL2, "QUAD:LI28:501:BMAX")
  field(DOL3, "QUAD:LI28:501:BMAX")
  field(DOL4, "QUAD:LI28:501:BMIN")
  field(DOL5, "QUAD:LI28:501:BMIN")
  field(DOL6, "QUAD:LI28:501:BMIN")
  field(LNK1, "QUAD:LI28:501:BMAGX.HOPR")
  field(LNK2, "QUAD:LI28:501:BMAGY.HOPR")
  field(LNK3, "QUAD:LI28:501:BLEM.HOPR")
  field(LNK4, "QUAD:LI28:501:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI28:501:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI28:501:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:501:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:501:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI28:501:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI28:501:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI28:501:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:501:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:501:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:501:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:501:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:501:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI28:501:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI28:501:EDES NPP MS")
  field(INPB, "QUAD:LI28:501:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI28:601:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI28:601:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI28:601:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI28:601:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI28:601:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI28:601:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI28:601:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI28:601:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI28:601:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI28:601:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI28:601:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI28:601:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI28:601:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI28:601:EDES.PROC PP")
    field(LNK2, "QUAD:LI28:601:EACT.PROC PP")
    field(LNK3, "QUAD:LI28:601:EERR.DISA PP")
    field(LNK4, "QUAD:LI28:601:ECON.PROC PP")
    field(LNK5, "QUAD:LI28:601:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI28:601:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI28:601:BLEM.PROC PP")
    field(LNK8, "QUAD:LI28:601:BMOD.PROC PP")
    field(LNK9, "QUAD:LI28:601:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI28:601:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI28:601:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI28:601:BMAX")
  field(DOL2, "QUAD:LI28:601:BMAX")
  field(DOL3, "QUAD:LI28:601:BMAX")
  field(DOL4, "QUAD:LI28:601:BMIN")
  field(DOL5, "QUAD:LI28:601:BMIN")
  field(DOL6, "QUAD:LI28:601:BMIN")
  field(LNK1, "QUAD:LI28:601:BMAGX.HOPR")
  field(LNK2, "QUAD:LI28:601:BMAGY.HOPR")
  field(LNK3, "QUAD:LI28:601:BLEM.HOPR")
  field(LNK4, "QUAD:LI28:601:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI28:601:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI28:601:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:601:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:601:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI28:601:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI28:601:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI28:601:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:601:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:601:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:601:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:601:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:601:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI28:601:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI28:601:EDES NPP MS")
  field(INPB, "QUAD:LI28:601:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI28:701:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI28:701:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI28:701:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI28:701:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI28:701:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI28:701:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI28:701:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI28:701:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI28:701:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI28:701:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI28:701:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI28:701:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI28:701:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI28:701:EDES.PROC PP")
    field(LNK2, "QUAD:LI28:701:EACT.PROC PP")
    field(LNK3, "QUAD:LI28:701:EERR.DISA PP")
    field(LNK4, "QUAD:LI28:701:ECON.PROC PP")
    field(LNK5, "QUAD:LI28:701:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI28:701:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI28:701:BLEM.PROC PP")
    field(LNK8, "QUAD:LI28:701:BMOD.PROC PP")
    field(LNK9, "QUAD:LI28:701:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI28:701:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI28:701:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI28:701:BMAX")
  field(DOL2, "QUAD:LI28:701:BMAX")
  field(DOL3, "QUAD:LI28:701:BMAX")
  field(DOL4, "QUAD:LI28:701:BMIN")
  field(DOL5, "QUAD:LI28:701:BMIN")
  field(DOL6, "QUAD:LI28:701:BMIN")
  field(LNK1, "QUAD:LI28:701:BMAGX.HOPR")
  field(LNK2, "QUAD:LI28:701:BMAGY.HOPR")
  field(LNK3, "QUAD:LI28:701:BLEM.HOPR")
  field(LNK4, "QUAD:LI28:701:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI28:701:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI28:701:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:701:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:701:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI28:701:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI28:701:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI28:701:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:701:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:701:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:701:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:701:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:701:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI28:701:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI28:701:EDES NPP MS")
  field(INPB, "QUAD:LI28:701:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI28:801:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI28:801:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI28:801:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI28:801:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI28:801:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI28:801:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI28:801:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI28:801:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI28:801:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI28:801:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI28:801:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI28:801:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI28:801:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI28:801:EDES.PROC PP")
    field(LNK2, "QUAD:LI28:801:EACT.PROC PP")
    field(LNK3, "QUAD:LI28:801:EERR.DISA PP")
    field(LNK4, "QUAD:LI28:801:ECON.PROC PP")
    field(LNK5, "QUAD:LI28:801:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI28:801:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI28:801:BLEM.PROC PP")
    field(LNK8, "QUAD:LI28:801:BMOD.PROC PP")
    field(LNK9, "QUAD:LI28:801:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI28:801:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI28:801:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI28:801:BMAX")
  field(DOL2, "QUAD:LI28:801:BMAX")
  field(DOL3, "QUAD:LI28:801:BMAX")
  field(DOL4, "QUAD:LI28:801:BMIN")
  field(DOL5, "QUAD:LI28:801:BMIN")
  field(DOL6, "QUAD:LI28:801:BMIN")
  field(LNK1, "QUAD:LI28:801:BMAGX.HOPR")
  field(LNK2, "QUAD:LI28:801:BMAGY.HOPR")
  field(LNK3, "QUAD:LI28:801:BLEM.HOPR")
  field(LNK4, "QUAD:LI28:801:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI28:801:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI28:801:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:801:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:801:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI28:801:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI28:801:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI28:801:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:801:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:801:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:801:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:801:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:801:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI28:801:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI28:801:EDES NPP MS")
  field(INPB, "QUAD:LI28:801:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI28:901:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI28:901:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI28:901:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI28:901:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI28:901:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI28:901:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI28:901:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI28:901:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI28:901:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI28:901:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI28:901:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI28:901:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI28:901:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI28:901:EDES.PROC PP")
    field(LNK2, "QUAD:LI28:901:EACT.PROC PP")
    field(LNK3, "QUAD:LI28:901:EERR.DISA PP")
    field(LNK4, "QUAD:LI28:901:ECON.PROC PP")
    field(LNK5, "QUAD:LI28:901:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI28:901:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI28:901:BLEM.PROC PP")
    field(LNK8, "QUAD:LI28:901:BMOD.PROC PP")
    field(LNK9, "QUAD:LI28:901:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI28:901:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI28:901:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI28:901:BMAX")
  field(DOL2, "QUAD:LI28:901:BMAX")
  field(DOL3, "QUAD:LI28:901:BMAX")
  field(DOL4, "QUAD:LI28:901:BMIN")
  field(DOL5, "QUAD:LI28:901:BMIN")
  field(DOL6, "QUAD:LI28:901:BMIN")
  field(LNK1, "QUAD:LI28:901:BMAGX.HOPR")
  field(LNK2, "QUAD:LI28:901:BMAGY.HOPR")
  field(LNK3, "QUAD:LI28:901:BLEM.HOPR")
  field(LNK4, "QUAD:LI28:901:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI28:901:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI28:901:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:901:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI28:901:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI28:901:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI28:901:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI28:901:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:901:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:901:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:901:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI28:901:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI28:901:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI28:901:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI28:901:EDES NPP MS")
  field(INPB, "QUAD:LI28:901:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI28:202:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI28:202:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI28:202:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI28:202:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI28:202:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI28:202:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI28:202:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI28:202:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI28:202:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI28:202:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI28:202:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI28:202:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI28:202:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI28:202:EDES.PROC PP")
    field(LNK2, "XCOR:LI28:202:EACT.PROC PP")
    field(LNK3, "XCOR:LI28:202:EERR.DISA PP")
    field(LNK4, "XCOR:LI28:202:ECON.PROC PP")
    field(LNK5, "XCOR:LI28:202:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI28:202:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI28:202:BLEM.PROC PP")
    field(LNK8, "XCOR:LI28:202:BMOD.PROC PP")
    field(LNK9, "XCOR:LI28:202:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI28:202:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI28:202:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI28:202:BMAX")
  field(DOL2, "XCOR:LI28:202:BMAX")
  field(DOL3, "XCOR:LI28:202:BMAX")
  field(DOL4, "XCOR:LI28:202:BMIN")
  field(DOL5, "XCOR:LI28:202:BMIN")
  field(DOL6, "XCOR:LI28:202:BMIN")
  field(LNK1, "XCOR:LI28:202:BMAGX.HOPR")
  field(LNK2, "XCOR:LI28:202:BMAGY.HOPR")
  field(LNK3, "XCOR:LI28:202:BLEM.HOPR")
  field(LNK4, "XCOR:LI28:202:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI28:202:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI28:202:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:202:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:202:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI28:202:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI28:202:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI28:202:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:202:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:202:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:202:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:202:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:202:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI28:202:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI28:202:EDES NPP MS")
  field(INPB, "XCOR:LI28:202:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI28:302:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI28:302:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI28:302:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI28:302:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI28:302:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI28:302:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI28:302:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI28:302:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI28:302:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI28:302:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI28:302:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI28:302:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI28:302:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI28:302:EDES.PROC PP")
    field(LNK2, "XCOR:LI28:302:EACT.PROC PP")
    field(LNK3, "XCOR:LI28:302:EERR.DISA PP")
    field(LNK4, "XCOR:LI28:302:ECON.PROC PP")
    field(LNK5, "XCOR:LI28:302:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI28:302:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI28:302:BLEM.PROC PP")
    field(LNK8, "XCOR:LI28:302:BMOD.PROC PP")
    field(LNK9, "XCOR:LI28:302:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI28:302:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI28:302:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI28:302:BMAX")
  field(DOL2, "XCOR:LI28:302:BMAX")
  field(DOL3, "XCOR:LI28:302:BMAX")
  field(DOL4, "XCOR:LI28:302:BMIN")
  field(DOL5, "XCOR:LI28:302:BMIN")
  field(DOL6, "XCOR:LI28:302:BMIN")
  field(LNK1, "XCOR:LI28:302:BMAGX.HOPR")
  field(LNK2, "XCOR:LI28:302:BMAGY.HOPR")
  field(LNK3, "XCOR:LI28:302:BLEM.HOPR")
  field(LNK4, "XCOR:LI28:302:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI28:302:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI28:302:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:302:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:302:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI28:302:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI28:302:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI28:302:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:302:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:302:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:302:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:302:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:302:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI28:302:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI28:302:EDES NPP MS")
  field(INPB, "XCOR:LI28:302:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI28:402:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI28:402:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI28:402:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI28:402:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI28:402:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI28:402:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI28:402:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI28:402:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI28:402:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI28:402:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI28:402:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI28:402:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI28:402:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI28:402:EDES.PROC PP")
    field(LNK2, "XCOR:LI28:402:EACT.PROC PP")
    field(LNK3, "XCOR:LI28:402:EERR.DISA PP")
    field(LNK4, "XCOR:LI28:402:ECON.PROC PP")
    field(LNK5, "XCOR:LI28:402:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI28:402:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI28:402:BLEM.PROC PP")
    field(LNK8, "XCOR:LI28:402:BMOD.PROC PP")
    field(LNK9, "XCOR:LI28:402:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI28:402:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI28:402:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI28:402:BMAX")
  field(DOL2, "XCOR:LI28:402:BMAX")
  field(DOL3, "XCOR:LI28:402:BMAX")
  field(DOL4, "XCOR:LI28:402:BMIN")
  field(DOL5, "XCOR:LI28:402:BMIN")
  field(DOL6, "XCOR:LI28:402:BMIN")
  field(LNK1, "XCOR:LI28:402:BMAGX.HOPR")
  field(LNK2, "XCOR:LI28:402:BMAGY.HOPR")
  field(LNK3, "XCOR:LI28:402:BLEM.HOPR")
  field(LNK4, "XCOR:LI28:402:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI28:402:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI28:402:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:402:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:402:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI28:402:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI28:402:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI28:402:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:402:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:402:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:402:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:402:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:402:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI28:402:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI28:402:EDES NPP MS")
  field(INPB, "XCOR:LI28:402:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI28:502:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI28:502:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI28:502:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI28:502:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI28:502:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI28:502:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI28:502:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI28:502:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI28:502:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI28:502:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI28:502:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI28:502:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI28:502:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI28:502:EDES.PROC PP")
    field(LNK2, "XCOR:LI28:502:EACT.PROC PP")
    field(LNK3, "XCOR:LI28:502:EERR.DISA PP")
    field(LNK4, "XCOR:LI28:502:ECON.PROC PP")
    field(LNK5, "XCOR:LI28:502:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI28:502:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI28:502:BLEM.PROC PP")
    field(LNK8, "XCOR:LI28:502:BMOD.PROC PP")
    field(LNK9, "XCOR:LI28:502:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI28:502:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI28:502:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI28:502:BMAX")
  field(DOL2, "XCOR:LI28:502:BMAX")
  field(DOL3, "XCOR:LI28:502:BMAX")
  field(DOL4, "XCOR:LI28:502:BMIN")
  field(DOL5, "XCOR:LI28:502:BMIN")
  field(DOL6, "XCOR:LI28:502:BMIN")
  field(LNK1, "XCOR:LI28:502:BMAGX.HOPR")
  field(LNK2, "XCOR:LI28:502:BMAGY.HOPR")
  field(LNK3, "XCOR:LI28:502:BLEM.HOPR")
  field(LNK4, "XCOR:LI28:502:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI28:502:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI28:502:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:502:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:502:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI28:502:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI28:502:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI28:502:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:502:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:502:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:502:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:502:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:502:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI28:502:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI28:502:EDES NPP MS")
  field(INPB, "XCOR:LI28:502:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI28:602:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI28:602:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI28:602:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI28:602:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI28:602:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI28:602:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI28:602:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI28:602:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI28:602:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI28:602:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI28:602:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI28:602:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI28:602:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI28:602:EDES.PROC PP")
    field(LNK2, "XCOR:LI28:602:EACT.PROC PP")
    field(LNK3, "XCOR:LI28:602:EERR.DISA PP")
    field(LNK4, "XCOR:LI28:602:ECON.PROC PP")
    field(LNK5, "XCOR:LI28:602:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI28:602:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI28:602:BLEM.PROC PP")
    field(LNK8, "XCOR:LI28:602:BMOD.PROC PP")
    field(LNK9, "XCOR:LI28:602:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI28:602:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI28:602:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI28:602:BMAX")
  field(DOL2, "XCOR:LI28:602:BMAX")
  field(DOL3, "XCOR:LI28:602:BMAX")
  field(DOL4, "XCOR:LI28:602:BMIN")
  field(DOL5, "XCOR:LI28:602:BMIN")
  field(DOL6, "XCOR:LI28:602:BMIN")
  field(LNK1, "XCOR:LI28:602:BMAGX.HOPR")
  field(LNK2, "XCOR:LI28:602:BMAGY.HOPR")
  field(LNK3, "XCOR:LI28:602:BLEM.HOPR")
  field(LNK4, "XCOR:LI28:602:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI28:602:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI28:602:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:602:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:602:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI28:602:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI28:602:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI28:602:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:602:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:602:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:602:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:602:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:602:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI28:602:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI28:602:EDES NPP MS")
  field(INPB, "XCOR:LI28:602:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI28:702:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI28:702:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI28:702:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI28:702:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI28:702:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI28:702:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI28:702:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI28:702:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI28:702:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI28:702:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI28:702:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI28:702:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI28:702:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI28:702:EDES.PROC PP")
    field(LNK2, "XCOR:LI28:702:EACT.PROC PP")
    field(LNK3, "XCOR:LI28:702:EERR.DISA PP")
    field(LNK4, "XCOR:LI28:702:ECON.PROC PP")
    field(LNK5, "XCOR:LI28:702:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI28:702:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI28:702:BLEM.PROC PP")
    field(LNK8, "XCOR:LI28:702:BMOD.PROC PP")
    field(LNK9, "XCOR:LI28:702:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI28:702:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI28:702:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI28:702:BMAX")
  field(DOL2, "XCOR:LI28:702:BMAX")
  field(DOL3, "XCOR:LI28:702:BMAX")
  field(DOL4, "XCOR:LI28:702:BMIN")
  field(DOL5, "XCOR:LI28:702:BMIN")
  field(DOL6, "XCOR:LI28:702:BMIN")
  field(LNK1, "XCOR:LI28:702:BMAGX.HOPR")
  field(LNK2, "XCOR:LI28:702:BMAGY.HOPR")
  field(LNK3, "XCOR:LI28:702:BLEM.HOPR")
  field(LNK4, "XCOR:LI28:702:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI28:702:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI28:702:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:702:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:702:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI28:702:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI28:702:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI28:702:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:702:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:702:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:702:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:702:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:702:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI28:702:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI28:702:EDES NPP MS")
  field(INPB, "XCOR:LI28:702:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI28:802:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI28:802:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI28:802:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI28:802:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI28:802:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI28:802:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI28:802:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI28:802:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI28:802:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI28:802:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI28:802:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI28:802:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI28:802:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI28:802:EDES.PROC PP")
    field(LNK2, "XCOR:LI28:802:EACT.PROC PP")
    field(LNK3, "XCOR:LI28:802:EERR.DISA PP")
    field(LNK4, "XCOR:LI28:802:ECON.PROC PP")
    field(LNK5, "XCOR:LI28:802:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI28:802:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI28:802:BLEM.PROC PP")
    field(LNK8, "XCOR:LI28:802:BMOD.PROC PP")
    field(LNK9, "XCOR:LI28:802:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI28:802:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI28:802:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI28:802:BMAX")
  field(DOL2, "XCOR:LI28:802:BMAX")
  field(DOL3, "XCOR:LI28:802:BMAX")
  field(DOL4, "XCOR:LI28:802:BMIN")
  field(DOL5, "XCOR:LI28:802:BMIN")
  field(DOL6, "XCOR:LI28:802:BMIN")
  field(LNK1, "XCOR:LI28:802:BMAGX.HOPR")
  field(LNK2, "XCOR:LI28:802:BMAGY.HOPR")
  field(LNK3, "XCOR:LI28:802:BLEM.HOPR")
  field(LNK4, "XCOR:LI28:802:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI28:802:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI28:802:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:802:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:802:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI28:802:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI28:802:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI28:802:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:802:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:802:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:802:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:802:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:802:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI28:802:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI28:802:EDES NPP MS")
  field(INPB, "XCOR:LI28:802:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI28:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI28:900:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI28:900:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI28:900:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI28:900:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI28:900:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI28:900:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI28:900:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI28:900:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI28:900:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI28:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI28:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI28:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI28:900:EDES.PROC PP")
    field(LNK2, "XCOR:LI28:900:EACT.PROC PP")
    field(LNK3, "XCOR:LI28:900:EERR.DISA PP")
    field(LNK4, "XCOR:LI28:900:ECON.PROC PP")
    field(LNK5, "XCOR:LI28:900:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI28:900:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI28:900:BLEM.PROC PP")
    field(LNK8, "XCOR:LI28:900:BMOD.PROC PP")
    field(LNK9, "XCOR:LI28:900:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI28:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI28:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI28:900:BMAX")
  field(DOL2, "XCOR:LI28:900:BMAX")
  field(DOL3, "XCOR:LI28:900:BMAX")
  field(DOL4, "XCOR:LI28:900:BMIN")
  field(DOL5, "XCOR:LI28:900:BMIN")
  field(DOL6, "XCOR:LI28:900:BMIN")
  field(LNK1, "XCOR:LI28:900:BMAGX.HOPR")
  field(LNK2, "XCOR:LI28:900:BMAGY.HOPR")
  field(LNK3, "XCOR:LI28:900:BLEM.HOPR")
  field(LNK4, "XCOR:LI28:900:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI28:900:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI28:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI28:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI28:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI28:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI28:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI28:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI28:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI28:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI28:900:EDES NPP MS")
  field(INPB, "XCOR:LI28:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI28:203:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI28:203:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI28:203:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI28:203:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI28:203:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI28:203:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI28:203:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI28:203:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI28:203:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI28:203:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI28:203:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI28:203:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI28:203:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI28:203:EDES.PROC PP")
    field(LNK2, "YCOR:LI28:203:EACT.PROC PP")
    field(LNK3, "YCOR:LI28:203:EERR.DISA PP")
    field(LNK4, "YCOR:LI28:203:ECON.PROC PP")
    field(LNK5, "YCOR:LI28:203:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI28:203:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI28:203:BLEM.PROC PP")
    field(LNK8, "YCOR:LI28:203:BMOD.PROC PP")
    field(LNK9, "YCOR:LI28:203:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI28:203:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI28:203:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI28:203:BMAX")
  field(DOL2, "YCOR:LI28:203:BMAX")
  field(DOL3, "YCOR:LI28:203:BMAX")
  field(DOL4, "YCOR:LI28:203:BMIN")
  field(DOL5, "YCOR:LI28:203:BMIN")
  field(DOL6, "YCOR:LI28:203:BMIN")
  field(LNK1, "YCOR:LI28:203:BMAGX.HOPR")
  field(LNK2, "YCOR:LI28:203:BMAGY.HOPR")
  field(LNK3, "YCOR:LI28:203:BLEM.HOPR")
  field(LNK4, "YCOR:LI28:203:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI28:203:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI28:203:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:203:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:203:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI28:203:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI28:203:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI28:203:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:203:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:203:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:203:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:203:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:203:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI28:203:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI28:203:EDES NPP MS")
  field(INPB, "YCOR:LI28:203:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI28:303:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI28:303:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI28:303:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI28:303:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI28:303:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI28:303:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI28:303:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI28:303:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI28:303:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI28:303:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI28:303:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI28:303:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI28:303:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI28:303:EDES.PROC PP")
    field(LNK2, "YCOR:LI28:303:EACT.PROC PP")
    field(LNK3, "YCOR:LI28:303:EERR.DISA PP")
    field(LNK4, "YCOR:LI28:303:ECON.PROC PP")
    field(LNK5, "YCOR:LI28:303:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI28:303:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI28:303:BLEM.PROC PP")
    field(LNK8, "YCOR:LI28:303:BMOD.PROC PP")
    field(LNK9, "YCOR:LI28:303:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI28:303:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI28:303:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI28:303:BMAX")
  field(DOL2, "YCOR:LI28:303:BMAX")
  field(DOL3, "YCOR:LI28:303:BMAX")
  field(DOL4, "YCOR:LI28:303:BMIN")
  field(DOL5, "YCOR:LI28:303:BMIN")
  field(DOL6, "YCOR:LI28:303:BMIN")
  field(LNK1, "YCOR:LI28:303:BMAGX.HOPR")
  field(LNK2, "YCOR:LI28:303:BMAGY.HOPR")
  field(LNK3, "YCOR:LI28:303:BLEM.HOPR")
  field(LNK4, "YCOR:LI28:303:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI28:303:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI28:303:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:303:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:303:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI28:303:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI28:303:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI28:303:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:303:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:303:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:303:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:303:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:303:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI28:303:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI28:303:EDES NPP MS")
  field(INPB, "YCOR:LI28:303:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI28:403:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI28:403:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI28:403:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI28:403:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI28:403:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI28:403:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI28:403:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI28:403:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI28:403:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI28:403:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI28:403:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI28:403:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI28:403:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI28:403:EDES.PROC PP")
    field(LNK2, "YCOR:LI28:403:EACT.PROC PP")
    field(LNK3, "YCOR:LI28:403:EERR.DISA PP")
    field(LNK4, "YCOR:LI28:403:ECON.PROC PP")
    field(LNK5, "YCOR:LI28:403:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI28:403:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI28:403:BLEM.PROC PP")
    field(LNK8, "YCOR:LI28:403:BMOD.PROC PP")
    field(LNK9, "YCOR:LI28:403:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI28:403:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI28:403:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI28:403:BMAX")
  field(DOL2, "YCOR:LI28:403:BMAX")
  field(DOL3, "YCOR:LI28:403:BMAX")
  field(DOL4, "YCOR:LI28:403:BMIN")
  field(DOL5, "YCOR:LI28:403:BMIN")
  field(DOL6, "YCOR:LI28:403:BMIN")
  field(LNK1, "YCOR:LI28:403:BMAGX.HOPR")
  field(LNK2, "YCOR:LI28:403:BMAGY.HOPR")
  field(LNK3, "YCOR:LI28:403:BLEM.HOPR")
  field(LNK4, "YCOR:LI28:403:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI28:403:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI28:403:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:403:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:403:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI28:403:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI28:403:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI28:403:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:403:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:403:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:403:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:403:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:403:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI28:403:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI28:403:EDES NPP MS")
  field(INPB, "YCOR:LI28:403:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI28:503:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI28:503:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI28:503:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI28:503:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI28:503:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI28:503:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI28:503:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI28:503:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI28:503:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI28:503:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI28:503:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI28:503:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI28:503:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI28:503:EDES.PROC PP")
    field(LNK2, "YCOR:LI28:503:EACT.PROC PP")
    field(LNK3, "YCOR:LI28:503:EERR.DISA PP")
    field(LNK4, "YCOR:LI28:503:ECON.PROC PP")
    field(LNK5, "YCOR:LI28:503:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI28:503:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI28:503:BLEM.PROC PP")
    field(LNK8, "YCOR:LI28:503:BMOD.PROC PP")
    field(LNK9, "YCOR:LI28:503:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI28:503:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI28:503:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI28:503:BMAX")
  field(DOL2, "YCOR:LI28:503:BMAX")
  field(DOL3, "YCOR:LI28:503:BMAX")
  field(DOL4, "YCOR:LI28:503:BMIN")
  field(DOL5, "YCOR:LI28:503:BMIN")
  field(DOL6, "YCOR:LI28:503:BMIN")
  field(LNK1, "YCOR:LI28:503:BMAGX.HOPR")
  field(LNK2, "YCOR:LI28:503:BMAGY.HOPR")
  field(LNK3, "YCOR:LI28:503:BLEM.HOPR")
  field(LNK4, "YCOR:LI28:503:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI28:503:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI28:503:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:503:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:503:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI28:503:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI28:503:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI28:503:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:503:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:503:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:503:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:503:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:503:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI28:503:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI28:503:EDES NPP MS")
  field(INPB, "YCOR:LI28:503:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI28:603:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI28:603:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI28:603:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI28:603:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI28:603:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI28:603:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI28:603:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI28:603:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI28:603:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI28:603:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI28:603:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI28:603:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI28:603:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI28:603:EDES.PROC PP")
    field(LNK2, "YCOR:LI28:603:EACT.PROC PP")
    field(LNK3, "YCOR:LI28:603:EERR.DISA PP")
    field(LNK4, "YCOR:LI28:603:ECON.PROC PP")
    field(LNK5, "YCOR:LI28:603:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI28:603:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI28:603:BLEM.PROC PP")
    field(LNK8, "YCOR:LI28:603:BMOD.PROC PP")
    field(LNK9, "YCOR:LI28:603:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI28:603:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI28:603:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI28:603:BMAX")
  field(DOL2, "YCOR:LI28:603:BMAX")
  field(DOL3, "YCOR:LI28:603:BMAX")
  field(DOL4, "YCOR:LI28:603:BMIN")
  field(DOL5, "YCOR:LI28:603:BMIN")
  field(DOL6, "YCOR:LI28:603:BMIN")
  field(LNK1, "YCOR:LI28:603:BMAGX.HOPR")
  field(LNK2, "YCOR:LI28:603:BMAGY.HOPR")
  field(LNK3, "YCOR:LI28:603:BLEM.HOPR")
  field(LNK4, "YCOR:LI28:603:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI28:603:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI28:603:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:603:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:603:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI28:603:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI28:603:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI28:603:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:603:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:603:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:603:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:603:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:603:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI28:603:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI28:603:EDES NPP MS")
  field(INPB, "YCOR:LI28:603:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI28:703:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI28:703:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI28:703:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI28:703:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI28:703:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI28:703:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI28:703:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI28:703:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI28:703:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI28:703:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI28:703:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI28:703:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI28:703:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI28:703:EDES.PROC PP")
    field(LNK2, "YCOR:LI28:703:EACT.PROC PP")
    field(LNK3, "YCOR:LI28:703:EERR.DISA PP")
    field(LNK4, "YCOR:LI28:703:ECON.PROC PP")
    field(LNK5, "YCOR:LI28:703:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI28:703:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI28:703:BLEM.PROC PP")
    field(LNK8, "YCOR:LI28:703:BMOD.PROC PP")
    field(LNK9, "YCOR:LI28:703:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI28:703:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI28:703:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI28:703:BMAX")
  field(DOL2, "YCOR:LI28:703:BMAX")
  field(DOL3, "YCOR:LI28:703:BMAX")
  field(DOL4, "YCOR:LI28:703:BMIN")
  field(DOL5, "YCOR:LI28:703:BMIN")
  field(DOL6, "YCOR:LI28:703:BMIN")
  field(LNK1, "YCOR:LI28:703:BMAGX.HOPR")
  field(LNK2, "YCOR:LI28:703:BMAGY.HOPR")
  field(LNK3, "YCOR:LI28:703:BLEM.HOPR")
  field(LNK4, "YCOR:LI28:703:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI28:703:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI28:703:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:703:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:703:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI28:703:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI28:703:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI28:703:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:703:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:703:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:703:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:703:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:703:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI28:703:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI28:703:EDES NPP MS")
  field(INPB, "YCOR:LI28:703:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI28:803:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI28:803:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI28:803:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI28:803:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI28:803:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI28:803:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI28:803:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI28:803:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI28:803:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI28:803:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI28:803:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI28:803:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI28:803:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI28:803:EDES.PROC PP")
    field(LNK2, "YCOR:LI28:803:EACT.PROC PP")
    field(LNK3, "YCOR:LI28:803:EERR.DISA PP")
    field(LNK4, "YCOR:LI28:803:ECON.PROC PP")
    field(LNK5, "YCOR:LI28:803:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI28:803:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI28:803:BLEM.PROC PP")
    field(LNK8, "YCOR:LI28:803:BMOD.PROC PP")
    field(LNK9, "YCOR:LI28:803:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI28:803:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI28:803:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI28:803:BMAX")
  field(DOL2, "YCOR:LI28:803:BMAX")
  field(DOL3, "YCOR:LI28:803:BMAX")
  field(DOL4, "YCOR:LI28:803:BMIN")
  field(DOL5, "YCOR:LI28:803:BMIN")
  field(DOL6, "YCOR:LI28:803:BMIN")
  field(LNK1, "YCOR:LI28:803:BMAGX.HOPR")
  field(LNK2, "YCOR:LI28:803:BMAGY.HOPR")
  field(LNK3, "YCOR:LI28:803:BLEM.HOPR")
  field(LNK4, "YCOR:LI28:803:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI28:803:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI28:803:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:803:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:803:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI28:803:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI28:803:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI28:803:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:803:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:803:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:803:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:803:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:803:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI28:803:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI28:803:EDES NPP MS")
  field(INPB, "YCOR:LI28:803:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI28:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI28:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI28:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI28:900:FUNC CA PP")
  field(DOL2, "MGNT:LI28:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI28:900:FUNC CA PP")
  field(DOL3, "MGNT:LI28:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI28:900:FUNC CA PP")
  field(DOL4, "MGNT:LI28:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI28:900:FUNC CA PP")
  field(DOL5, "MGNT:LI28:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI28:900:FUNC CA PP")
  field(DOL6, "MGNT:LI28:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI28:900:FUNC CA PP")
  field(DOL7, "MGNT:LI28:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI28:900:FUNC CA PP")
  field(DOL8, "MGNT:LI28:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI28:900:FUNC CA PP")
  field(DOL9, "MGNT:LI28:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI28:900:FUNC CA PP")
  field(DOLA, "MGNT:LI28:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI28:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI28:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI28:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI28:900:EDES.PROC PP")
    field(LNK2, "YCOR:LI28:900:EACT.PROC PP")
    field(LNK3, "YCOR:LI28:900:EERR.DISA PP")
    field(LNK4, "YCOR:LI28:900:ECON.PROC PP")
    field(LNK5, "YCOR:LI28:900:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI28:900:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI28:900:BLEM.PROC PP")
    field(LNK8, "YCOR:LI28:900:BMOD.PROC PP")
    field(LNK9, "YCOR:LI28:900:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI28:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI28:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI28:900:BMAX")
  field(DOL2, "YCOR:LI28:900:BMAX")
  field(DOL3, "YCOR:LI28:900:BMAX")
  field(DOL4, "YCOR:LI28:900:BMIN")
  field(DOL5, "YCOR:LI28:900:BMIN")
  field(DOL6, "YCOR:LI28:900:BMIN")
  field(LNK1, "YCOR:LI28:900:BMAGX.HOPR")
  field(LNK2, "YCOR:LI28:900:BMAGY.HOPR")
  field(LNK3, "YCOR:LI28:900:BLEM.HOPR")
  field(LNK4, "YCOR:LI28:900:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI28:900:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI28:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI28:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI28:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI28:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI28:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI28:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI28:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI28:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI28:900:EDES NPP MS")
  field(INPB, "YCOR:LI28:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:LI29:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:LI29:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:LI29:1:CTRL CA PP")
  field(LNK2, "MGNT:LI29:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:LI29:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:LI29:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:LI29:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:LI29:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:LI29:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:LI29:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:LI29:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:LI29:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:LI29:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:LI29:1:ALLSWITCH")
}

record(seq, "MGNT:LI29:1:ALLSWITCH") {
  field(DOL1, "MGNT:LI29:1:CTRL.FFVL")
  field(LNK1, "MGNT:LI29:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI29:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI29:1:CTRL")
}

record(bo, "MGNT:LI29:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:LI29:1:ALLSTARGO")
}

record(fanout, "MGNT:LI29:1:ALLSTARGO") {
  field(LNK1, "MGNT:LI29:1:ALLBENDSGO")
  field(LNK2, "MGNT:LI29:1:ALLBTRMSGO")
  field(LNK3, "MGNT:LI29:1:ALLLGPSSGO")
  field(LNK4, "MGNT:LI29:1:ALLQUADSGO")
  field(LNK5, "MGNT:LI29:1:ALLXCORSGO")
  field(LNK6, "MGNT:LI29:1:ALLYCORSGO")
  field(FLNK, "MGNT:LI29:1:ALLSTARGO_2")
}
record(fanout, "MGNT:LI29:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:LI29:1:ALLSOLNSGO")
  field(LNK2, "MGNT:LI29:1:ALLKICKSGO")
  field(LNK3, "MGNT:LI29:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:LI29:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:LI29:1:BENDSWITCH")
}

record(seq, "MGNT:LI29:1:BENDSWITCH") {
  field(DOL1, "MGNT:LI29:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:LI29:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI29:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI29:1:BENDCTRL")
}

record(seq, "MGNT:LI29:1:ALLBENDSGO") {
  field(DOL1, "MGNT:LI29:1:ALLSTAR")
  field(LNK1, "MGNT:LI29:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:LI29:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI29:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI29:1:BENDCTRL",20,10,0,0,"MGNT:LI29:1:BENDCTRL")
#! Field("MGNT:LI29:1:BENDCTRL.FLNK",16777215,1,"MGNT:LI29:1:BENDCTRL.FLNK")
#! Link("MGNT:LI29:1:BENDCTRL.FLNK","MGNT:LI29:1:BENDSWITCH")
#! Field("MGNT:LI29:1:BENDCTRL.FFVL",16777215,1,"MGNT:LI29:1:BENDCTRL.FFVL")
#! Record("MGNT:LI29:1:BENDSWITCH",460,322,0,0,"MGNT:LI29:1:BENDSWITCH")
#! Field("MGNT:LI29:1:BENDSWITCH.DOL1",16777215,0,"MGNT:LI29:1:BENDSWITCH.DOL1")
#! Link("MGNT:LI29:1:BENDSWITCH.DOL1","MGNT:LI29:1:BENDCTRL.FFVL")
#! Field("MGNT:LI29:1:BENDSWITCH.LNK1",16777215,1,"MGNT:LI29:1:BENDSWITCH.LNK1")
#! Field("MGNT:LI29:1:BENDSWITCH.FLNK",16777215,1,"MGNT:LI29:1:BENDSWITCH.FLNK")
#! Record("MGNT:LI29:1:ALLBENDSGO",240,96,0,0,"MGNT:LI29:1:ALLBENDSGO")
#! Field("MGNT:LI29:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:LI29:1:ALLBENDSGO.DOL1")
#! Field("MGNT:LI29:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:LI29:1:ALLBENDSGO.LNK1")
#! Link("MGNT:LI29:1:ALLBENDSGO.LNK1","MGNT:LI29:1:ALLBENDS.VAL")
#! Record("MGNT:LI29:1:ALLBENDS",540,102,0,0,"MGNT:LI29:1:ALLBENDS")
#! Field("MGNT:LI29:1:ALLBENDS.VAL",16777215,0,"MGNT:LI29:1:ALLBENDS.VAL")
#! Field("MGNT:LI29:1:ALLBENDS.FLNK",16777215,1,"MGNT:LI29:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:LI29:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI29:1:BTRMSWITCH")
}

record(seq, "MGNT:LI29:1:BTRMSWITCH") {
  field(DOL1, "MGNT:LI29:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:LI29:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI29:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI29:1:BTRMCTRL")
}

record(seq, "MGNT:LI29:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:LI29:1:ALLSTAR")
  field(LNK1, "MGNT:LI29:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:LI29:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI29:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI29:1:BTRMCTRL",20,10,0,0,"MGNT:LI29:1:BTRMCTRL")
#! Field("MGNT:LI29:1:BTRMCTRL.FLNK",16777215,1,"MGNT:LI29:1:BTRMCTRL.FLNK")
#! Link("MGNT:LI29:1:BTRMCTRL.FLNK","MGNT:LI29:1:BTRMSWITCH")
#! Field("MGNT:LI29:1:BTRMCTRL.FFVL",16777215,1,"MGNT:LI29:1:BTRMCTRL.FFVL")
#! Record("MGNT:LI29:1:BTRMSWITCH",460,322,0,0,"MGNT:LI29:1:BTRMSWITCH")
#! Field("MGNT:LI29:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:LI29:1:BTRMSWITCH.DOL1")
#! Link("MGNT:LI29:1:BTRMSWITCH.DOL1","MGNT:LI29:1:BTRMCTRL.FFVL")
#! Field("MGNT:LI29:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:LI29:1:BTRMSWITCH.LNK1")
#! Field("MGNT:LI29:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:LI29:1:BTRMSWITCH.FLNK")
#! Record("MGNT:LI29:1:ALLBTRMSGO",240,96,0,0,"MGNT:LI29:1:ALLBTRMSGO")
#! Field("MGNT:LI29:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:LI29:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:LI29:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:LI29:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:LI29:1:ALLBTRMSGO.LNK1","MGNT:LI29:1:ALLBTRMS.VAL")
#! Record("MGNT:LI29:1:ALLBTRMS",540,102,0,0,"MGNT:LI29:1:ALLBTRMS")
#! Field("MGNT:LI29:1:ALLBTRMS.VAL",16777215,0,"MGNT:LI29:1:ALLBTRMS.VAL")
#! Field("MGNT:LI29:1:ALLBTRMS.FLNK",16777215,1,"MGNT:LI29:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:LI29:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LI29:1:LGPSSWITCH")
}

record(seq, "MGNT:LI29:1:LGPSSWITCH") {
  field(DOL1, "MGNT:LI29:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:LI29:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI29:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI29:1:LGPSCTRL")
}

record(seq, "MGNT:LI29:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:LI29:1:ALLSTAR")
  field(LNK1, "MGNT:LI29:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:LI29:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI29:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI29:1:LGPSCTRL",20,10,0,0,"MGNT:LI29:1:LGPSCTRL")
#! Field("MGNT:LI29:1:LGPSCTRL.FLNK",16777215,1,"MGNT:LI29:1:LGPSCTRL.FLNK")
#! Link("MGNT:LI29:1:LGPSCTRL.FLNK","MGNT:LI29:1:LGPSSWITCH")
#! Field("MGNT:LI29:1:LGPSCTRL.FFVL",16777215,1,"MGNT:LI29:1:LGPSCTRL.FFVL")
#! Record("MGNT:LI29:1:LGPSSWITCH",460,322,0,0,"MGNT:LI29:1:LGPSSWITCH")
#! Field("MGNT:LI29:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:LI29:1:LGPSSWITCH.DOL1")
#! Link("MGNT:LI29:1:LGPSSWITCH.DOL1","MGNT:LI29:1:LGPSCTRL.FFVL")
#! Field("MGNT:LI29:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:LI29:1:LGPSSWITCH.LNK1")
#! Field("MGNT:LI29:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:LI29:1:LGPSSWITCH.FLNK")
#! Record("MGNT:LI29:1:ALLLGPSSGO",240,96,0,0,"MGNT:LI29:1:ALLLGPSSGO")
#! Field("MGNT:LI29:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:LI29:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:LI29:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:LI29:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:LI29:1:ALLLGPSSGO.LNK1","MGNT:LI29:1:ALLLGPSS.VAL")
#! Record("MGNT:LI29:1:ALLLGPSS",540,102,0,0,"MGNT:LI29:1:ALLLGPSS")
#! Field("MGNT:LI29:1:ALLLGPSS.VAL",16777215,0,"MGNT:LI29:1:ALLLGPSS.VAL")
#! Field("MGNT:LI29:1:ALLLGPSS.FLNK",16777215,1,"MGNT:LI29:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:LI29:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:LI29:1:QUADSWITCH")
}

record(seq, "MGNT:LI29:1:QUADSWITCH") {
  field(DOL1, "MGNT:LI29:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:LI29:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI29:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI29:1:QUADCTRL")
}

record(seq, "MGNT:LI29:1:ALLQUADSGO") {
  field(DOL1, "MGNT:LI29:1:ALLSTAR")
  field(LNK1, "MGNT:LI29:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:LI29:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI29:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI29:1:QUADCTRL",20,10,0,0,"MGNT:LI29:1:QUADCTRL")
#! Field("MGNT:LI29:1:QUADCTRL.FLNK",16777215,1,"MGNT:LI29:1:QUADCTRL.FLNK")
#! Link("MGNT:LI29:1:QUADCTRL.FLNK","MGNT:LI29:1:QUADSWITCH")
#! Field("MGNT:LI29:1:QUADCTRL.FFVL",16777215,1,"MGNT:LI29:1:QUADCTRL.FFVL")
#! Record("MGNT:LI29:1:QUADSWITCH",460,322,0,0,"MGNT:LI29:1:QUADSWITCH")
#! Field("MGNT:LI29:1:QUADSWITCH.DOL1",16777215,0,"MGNT:LI29:1:QUADSWITCH.DOL1")
#! Link("MGNT:LI29:1:QUADSWITCH.DOL1","MGNT:LI29:1:QUADCTRL.FFVL")
#! Field("MGNT:LI29:1:QUADSWITCH.LNK1",16777215,1,"MGNT:LI29:1:QUADSWITCH.LNK1")
#! Field("MGNT:LI29:1:QUADSWITCH.FLNK",16777215,1,"MGNT:LI29:1:QUADSWITCH.FLNK")
#! Record("MGNT:LI29:1:ALLQUADSGO",240,96,0,0,"MGNT:LI29:1:ALLQUADSGO")
#! Field("MGNT:LI29:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:LI29:1:ALLQUADSGO.DOL1")
#! Field("MGNT:LI29:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:LI29:1:ALLQUADSGO.LNK1")
#! Link("MGNT:LI29:1:ALLQUADSGO.LNK1","MGNT:LI29:1:ALLQUADS.VAL")
#! Record("MGNT:LI29:1:ALLQUADS",540,102,0,0,"MGNT:LI29:1:ALLQUADS")
#! Field("MGNT:LI29:1:ALLQUADS.VAL",16777215,0,"MGNT:LI29:1:ALLQUADS.VAL")
#! Field("MGNT:LI29:1:ALLQUADS.FLNK",16777215,1,"MGNT:LI29:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:LI29:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:LI29:1:XCORSWITCH")
}

record(seq, "MGNT:LI29:1:XCORSWITCH") {
  field(DOL1, "MGNT:LI29:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:LI29:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI29:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI29:1:XCORCTRL")
}

record(seq, "MGNT:LI29:1:ALLXCORSGO") {
  field(DOL1, "MGNT:LI29:1:ALLSTAR")
  field(LNK1, "MGNT:LI29:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:LI29:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI29:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI29:1:XCORCTRL",20,10,0,0,"MGNT:LI29:1:XCORCTRL")
#! Field("MGNT:LI29:1:XCORCTRL.FLNK",16777215,1,"MGNT:LI29:1:XCORCTRL.FLNK")
#! Link("MGNT:LI29:1:XCORCTRL.FLNK","MGNT:LI29:1:XCORSWITCH")
#! Field("MGNT:LI29:1:XCORCTRL.FFVL",16777215,1,"MGNT:LI29:1:XCORCTRL.FFVL")
#! Record("MGNT:LI29:1:XCORSWITCH",460,322,0,0,"MGNT:LI29:1:XCORSWITCH")
#! Field("MGNT:LI29:1:XCORSWITCH.DOL1",16777215,0,"MGNT:LI29:1:XCORSWITCH.DOL1")
#! Link("MGNT:LI29:1:XCORSWITCH.DOL1","MGNT:LI29:1:XCORCTRL.FFVL")
#! Field("MGNT:LI29:1:XCORSWITCH.LNK1",16777215,1,"MGNT:LI29:1:XCORSWITCH.LNK1")
#! Field("MGNT:LI29:1:XCORSWITCH.FLNK",16777215,1,"MGNT:LI29:1:XCORSWITCH.FLNK")
#! Record("MGNT:LI29:1:ALLXCORSGO",240,96,0,0,"MGNT:LI29:1:ALLXCORSGO")
#! Field("MGNT:LI29:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:LI29:1:ALLXCORSGO.DOL1")
#! Field("MGNT:LI29:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:LI29:1:ALLXCORSGO.LNK1")
#! Link("MGNT:LI29:1:ALLXCORSGO.LNK1","MGNT:LI29:1:ALLXCORS.VAL")
#! Record("MGNT:LI29:1:ALLXCORS",540,102,0,0,"MGNT:LI29:1:ALLXCORS")
#! Field("MGNT:LI29:1:ALLXCORS.VAL",16777215,0,"MGNT:LI29:1:ALLXCORS.VAL")
#! Field("MGNT:LI29:1:ALLXCORS.FLNK",16777215,1,"MGNT:LI29:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:LI29:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:LI29:1:YCORSWITCH")
}

record(seq, "MGNT:LI29:1:YCORSWITCH") {
  field(DOL1, "MGNT:LI29:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:LI29:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI29:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI29:1:YCORCTRL")
}

record(seq, "MGNT:LI29:1:ALLYCORSGO") {
  field(DOL1, "MGNT:LI29:1:ALLSTAR")
  field(LNK1, "MGNT:LI29:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:LI29:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI29:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI29:1:YCORCTRL",20,10,0,0,"MGNT:LI29:1:YCORCTRL")
#! Field("MGNT:LI29:1:YCORCTRL.FLNK",16777215,1,"MGNT:LI29:1:YCORCTRL.FLNK")
#! Link("MGNT:LI29:1:YCORCTRL.FLNK","MGNT:LI29:1:YCORSWITCH")
#! Field("MGNT:LI29:1:YCORCTRL.FFVL",16777215,1,"MGNT:LI29:1:YCORCTRL.FFVL")
#! Record("MGNT:LI29:1:YCORSWITCH",460,322,0,0,"MGNT:LI29:1:YCORSWITCH")
#! Field("MGNT:LI29:1:YCORSWITCH.DOL1",16777215,0,"MGNT:LI29:1:YCORSWITCH.DOL1")
#! Link("MGNT:LI29:1:YCORSWITCH.DOL1","MGNT:LI29:1:YCORCTRL.FFVL")
#! Field("MGNT:LI29:1:YCORSWITCH.LNK1",16777215,1,"MGNT:LI29:1:YCORSWITCH.LNK1")
#! Field("MGNT:LI29:1:YCORSWITCH.FLNK",16777215,1,"MGNT:LI29:1:YCORSWITCH.FLNK")
#! Record("MGNT:LI29:1:ALLYCORSGO",240,96,0,0,"MGNT:LI29:1:ALLYCORSGO")
#! Field("MGNT:LI29:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:LI29:1:ALLYCORSGO.DOL1")
#! Field("MGNT:LI29:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:LI29:1:ALLYCORSGO.LNK1")
#! Link("MGNT:LI29:1:ALLYCORSGO.LNK1","MGNT:LI29:1:ALLYCORS.VAL")
#! Record("MGNT:LI29:1:ALLYCORS",540,102,0,0,"MGNT:LI29:1:ALLYCORS")
#! Field("MGNT:LI29:1:ALLYCORS.VAL",16777215,0,"MGNT:LI29:1:ALLYCORS.VAL")
#! Field("MGNT:LI29:1:ALLYCORS.FLNK",16777215,1,"MGNT:LI29:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:LI29:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:LI29:1:SOLNSWITCH")
}

record(seq, "MGNT:LI29:1:SOLNSWITCH") {
  field(DOL1, "MGNT:LI29:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:LI29:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI29:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI29:1:SOLNCTRL")
}

record(seq, "MGNT:LI29:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:LI29:1:ALLSTAR")
  field(LNK1, "MGNT:LI29:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:LI29:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI29:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI29:1:SOLNCTRL",20,10,0,0,"MGNT:LI29:1:SOLNCTRL")
#! Field("MGNT:LI29:1:SOLNCTRL.FLNK",16777215,1,"MGNT:LI29:1:SOLNCTRL.FLNK")
#! Link("MGNT:LI29:1:SOLNCTRL.FLNK","MGNT:LI29:1:SOLNSWITCH")
#! Field("MGNT:LI29:1:SOLNCTRL.FFVL",16777215,1,"MGNT:LI29:1:SOLNCTRL.FFVL")
#! Record("MGNT:LI29:1:SOLNSWITCH",460,322,0,0,"MGNT:LI29:1:SOLNSWITCH")
#! Field("MGNT:LI29:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:LI29:1:SOLNSWITCH.DOL1")
#! Link("MGNT:LI29:1:SOLNSWITCH.DOL1","MGNT:LI29:1:SOLNCTRL.FFVL")
#! Field("MGNT:LI29:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:LI29:1:SOLNSWITCH.LNK1")
#! Field("MGNT:LI29:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:LI29:1:SOLNSWITCH.FLNK")
#! Record("MGNT:LI29:1:ALLSOLNSGO",240,96,0,0,"MGNT:LI29:1:ALLSOLNSGO")
#! Field("MGNT:LI29:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:LI29:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:LI29:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:LI29:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:LI29:1:ALLSOLNSGO.LNK1","MGNT:LI29:1:ALLSOLNS.VAL")
#! Record("MGNT:LI29:1:ALLSOLNS",540,102,0,0,"MGNT:LI29:1:ALLSOLNS")
#! Field("MGNT:LI29:1:ALLSOLNS.VAL",16777215,0,"MGNT:LI29:1:ALLSOLNS.VAL")
#! Field("MGNT:LI29:1:ALLSOLNS.FLNK",16777215,1,"MGNT:LI29:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:LI29:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:LI29:1:KICKSWITCH")
}

record(seq, "MGNT:LI29:1:KICKSWITCH") {
  field(DOL1, "MGNT:LI29:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:LI29:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI29:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI29:1:KICKCTRL")
}

record(seq, "MGNT:LI29:1:ALLKICKSGO") {
  field(DOL1, "MGNT:LI29:1:ALLSTAR")
  field(LNK1, "MGNT:LI29:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:LI29:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI29:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI29:1:KICKCTRL",20,10,0,0,"MGNT:LI29:1:KICKCTRL")
#! Field("MGNT:LI29:1:KICKCTRL.FLNK",16777215,1,"MGNT:LI29:1:KICKCTRL.FLNK")
#! Link("MGNT:LI29:1:KICKCTRL.FLNK","MGNT:LI29:1:KICKSWITCH")
#! Field("MGNT:LI29:1:KICKCTRL.FFVL",16777215,1,"MGNT:LI29:1:KICKCTRL.FFVL")
#! Record("MGNT:LI29:1:KICKSWITCH",460,322,0,0,"MGNT:LI29:1:KICKSWITCH")
#! Field("MGNT:LI29:1:KICKSWITCH.DOL1",16777215,0,"MGNT:LI29:1:KICKSWITCH.DOL1")
#! Link("MGNT:LI29:1:KICKSWITCH.DOL1","MGNT:LI29:1:KICKCTRL.FFVL")
#! Field("MGNT:LI29:1:KICKSWITCH.LNK1",16777215,1,"MGNT:LI29:1:KICKSWITCH.LNK1")
#! Field("MGNT:LI29:1:KICKSWITCH.FLNK",16777215,1,"MGNT:LI29:1:KICKSWITCH.FLNK")
#! Record("MGNT:LI29:1:ALLKICKSGO",240,96,0,0,"MGNT:LI29:1:ALLKICKSGO")
#! Field("MGNT:LI29:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:LI29:1:ALLKICKSGO.DOL1")
#! Field("MGNT:LI29:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:LI29:1:ALLKICKSGO.LNK1")
#! Link("MGNT:LI29:1:ALLKICKSGO.LNK1","MGNT:LI29:1:ALLKICKS.VAL")
#! Record("MGNT:LI29:1:ALLKICKS",540,102,0,0,"MGNT:LI29:1:ALLKICKS")
#! Field("MGNT:LI29:1:ALLKICKS.VAL",16777215,0,"MGNT:LI29:1:ALLKICKS.VAL")
#! Field("MGNT:LI29:1:ALLKICKS.FLNK",16777215,1,"MGNT:LI29:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:LI29:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:LI29:1:SEXTSWITCH")
}

record(seq, "MGNT:LI29:1:SEXTSWITCH") {
  field(DOL1, "MGNT:LI29:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:LI29:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LI29:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LI29:1:SEXTCTRL")
}

record(seq, "MGNT:LI29:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:LI29:1:ALLSTAR")
  field(LNK1, "MGNT:LI29:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:LI29:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LI29:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LI29:1:SEXTCTRL",20,10,0,0,"MGNT:LI29:1:SEXTCTRL")
#! Field("MGNT:LI29:1:SEXTCTRL.FLNK",16777215,1,"MGNT:LI29:1:SEXTCTRL.FLNK")
#! Link("MGNT:LI29:1:SEXTCTRL.FLNK","MGNT:LI29:1:SEXTSWITCH")
#! Field("MGNT:LI29:1:SEXTCTRL.FFVL",16777215,1,"MGNT:LI29:1:SEXTCTRL.FFVL")
#! Record("MGNT:LI29:1:SEXTSWITCH",460,322,0,0,"MGNT:LI29:1:SEXTSWITCH")
#! Field("MGNT:LI29:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:LI29:1:SEXTSWITCH.DOL1")
#! Link("MGNT:LI29:1:SEXTSWITCH.DOL1","MGNT:LI29:1:SEXTCTRL.FFVL")
#! Field("MGNT:LI29:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:LI29:1:SEXTSWITCH.LNK1")
#! Field("MGNT:LI29:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:LI29:1:SEXTSWITCH.FLNK")
#! Record("MGNT:LI29:1:ALLSEXTSGO",240,96,0,0,"MGNT:LI29:1:ALLSEXTSGO")
#! Field("MGNT:LI29:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:LI29:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:LI29:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:LI29:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:LI29:1:ALLSEXTSGO.LNK1","MGNT:LI29:1:ALLSEXTS.VAL")
#! Record("MGNT:LI29:1:ALLSEXTS",540,102,0,0,"MGNT:LI29:1:ALLSEXTS")
#! Field("MGNT:LI29:1:ALLSEXTS.VAL",16777215,0,"MGNT:LI29:1:ALLSEXTS.VAL")
#! Field("MGNT:LI29:1:ALLSEXTS.FLNK",16777215,1,"MGNT:LI29:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record (seq, "MGNT:LI29:1:ALLBENDSSEL"){
}
record (seq, "MGNT:LI29:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:LI29:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:LI29:1:ALLKICKSSEL"){
}
record (seq, "MGNT:LI29:1:ALLSEXTSSEL"){
}

record (seq, "MGNT:LI29:1:ALLLGPSSSEL"){
  field (DOL1, "MGNT:LI29:1:ALLLGPSS")
  field (LNK1, "LGPS:LI29:2:SELECT CPP NMS")
}

record (seq, "MGNT:LI29:1:ALLQUADSSEL"){
  field (DOL1, "MGNT:LI29:1:ALLQUADS")
  field (DOL2, "MGNT:LI29:1:ALLQUADS")
  field (DOL3, "MGNT:LI29:1:ALLQUADS")
  field (DOL4, "MGNT:LI29:1:ALLQUADS")
  field (DOL5, "MGNT:LI29:1:ALLQUADS")
  field (DOL6, "MGNT:LI29:1:ALLQUADS")
  field (DOL7, "MGNT:LI29:1:ALLQUADS")
  field (DOL8, "MGNT:LI29:1:ALLQUADS")
  field (LNK1, "QUAD:LI29:201:SELECT CPP NMS")
  field (LNK2, "QUAD:LI29:301:SELECT CPP NMS")
  field (LNK3, "QUAD:LI29:401:SELECT CPP NMS")
  field (LNK4, "QUAD:LI29:501:SELECT CPP NMS")
  field (LNK5, "QUAD:LI29:601:SELECT CPP NMS")
  field (LNK6, "QUAD:LI29:701:SELECT CPP NMS")
  field (LNK7, "QUAD:LI29:801:SELECT CPP NMS")
  field (LNK8, "QUAD:LI29:901:SELECT CPP NMS")
}

record (seq, "MGNT:LI29:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:LI29:1:ALLXCORS")
  field (DOL2, "MGNT:LI29:1:ALLXCORS")
  field (DOL3, "MGNT:LI29:1:ALLXCORS")
  field (DOL4, "MGNT:LI29:1:ALLXCORS")
  field (DOL5, "MGNT:LI29:1:ALLXCORS")
  field (DOL6, "MGNT:LI29:1:ALLXCORS")
  field (DOL7, "MGNT:LI29:1:ALLXCORS")
  field (DOL8, "MGNT:LI29:1:ALLXCORS")
  field (LNK1, "XCOR:LI29:202:SELECT CPP NMS")
  field (LNK2, "XCOR:LI29:302:SELECT CPP NMS")
  field (LNK3, "XCOR:LI29:402:SELECT CPP NMS")
  field (LNK4, "XCOR:LI29:502:SELECT CPP NMS")
  field (LNK5, "XCOR:LI29:602:SELECT CPP NMS")
  field (LNK6, "XCOR:LI29:702:SELECT CPP NMS")
  field (LNK7, "XCOR:LI29:802:SELECT CPP NMS")
  field (LNK8, "XCOR:LI29:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI29:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:LI29:1:ALLYCORS")
  field (DOL2, "MGNT:LI29:1:ALLYCORS")
  field (DOL3, "MGNT:LI29:1:ALLYCORS")
  field (DOL4, "MGNT:LI29:1:ALLYCORS")
  field (DOL5, "MGNT:LI29:1:ALLYCORS")
  field (DOL6, "MGNT:LI29:1:ALLYCORS")
  field (DOL7, "MGNT:LI29:1:ALLYCORS")
  field (DOL8, "MGNT:LI29:1:ALLYCORS")
  field (LNK1, "YCOR:LI29:203:SELECT CPP NMS")
  field (LNK2, "YCOR:LI29:303:SELECT CPP NMS")
  field (LNK3, "YCOR:LI29:403:SELECT CPP NMS")
  field (LNK4, "YCOR:LI29:503:SELECT CPP NMS")
  field (LNK5, "YCOR:LI29:603:SELECT CPP NMS")
  field (LNK6, "YCOR:LI29:703:SELECT CPP NMS")
  field (LNK7, "YCOR:LI29:803:SELECT CPP NMS")
  field (LNK8, "YCOR:LI29:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI29:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (LNK1, "MGNT:LI29:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:LI29:1:QUADFUNCGO.PROC")
  field (LNK3, "MGNT:LI29:1:XCORFUNCGO.PROC")
  field (LNK4, "MGNT:LI29:1:YCORFUNCGO.PROC")
  field (LNK5, "MGNT:LI29:1:LGPSFUNCGO.PROC")
  field (LNK6, "MGNT:LI29:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:LI29:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI29:1:QUADFUNCGO") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI29:201:ALLFUNCGO")
  field (LNK2, "QUAD:LI29:301:ALLFUNCGO")
  field (LNK3, "QUAD:LI29:401:ALLFUNCGO")
  field (LNK4, "QUAD:LI29:501:ALLFUNCGO")
  field (LNK5, "QUAD:LI29:601:ALLFUNCGO")
  field (LNK6, "QUAD:LI29:701:ALLFUNCGO")
  field (FLNK, "MGNT:LI29:1:QUADFUNCGO1")
}

record (fanout, "MGNT:LI29:1:QUADFUNCGO1") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI29:801:ALLFUNCGO")
  field (LNK2, "QUAD:LI29:901:ALLFUNCGO")
  field (FLNK, "MGNT:LI29:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI29:1:XCORFUNCGO") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI29:202:ALLFUNCGO")
  field (LNK2, "XCOR:LI29:302:ALLFUNCGO")
  field (LNK3, "XCOR:LI29:402:ALLFUNCGO")
  field (LNK4, "XCOR:LI29:502:ALLFUNCGO")
  field (LNK5, "XCOR:LI29:602:ALLFUNCGO")
  field (LNK6, "XCOR:LI29:702:ALLFUNCGO")
  field (FLNK, "MGNT:LI29:1:XCORFUNCGO1")
}

record (fanout, "MGNT:LI29:1:XCORFUNCGO1") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI29:802:ALLFUNCGO")
  field (LNK2, "XCOR:LI29:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI29:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI29:1:YCORFUNCGO") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI29:203:ALLFUNCGO")
  field (LNK2, "YCOR:LI29:303:ALLFUNCGO")
  field (LNK3, "YCOR:LI29:403:ALLFUNCGO")
  field (LNK4, "YCOR:LI29:503:ALLFUNCGO")
  field (LNK5, "YCOR:LI29:603:ALLFUNCGO")
  field (LNK6, "YCOR:LI29:703:ALLFUNCGO")
  field (FLNK, "MGNT:LI29:1:YCORFUNCGO1")
}

record (fanout, "MGNT:LI29:1:YCORFUNCGO1") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI29:803:ALLFUNCGO")
  field (LNK2, "YCOR:LI29:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI29:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI29:1:LGPSFUNCGO"){
  field (DESC, "Process LGPS CTRL func")
  field (LNK1, "LGPS:LI29:2:ALLFUNCGO")
  field (FLNK, "MGNT:LI29:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI29:1:BENDFUNCGO"){
  field (DESC, "Process BEND CTRL func")
  field (FLNK, "MGNT:LI29:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI29:1:BTRMFUNCGO"){
  field (DESC, "Process BTRM CTRL func")
  field (FLNK, "MGNT:LI29:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI29:1:SOLNFUNCGO"){
  field (DESC, "Process SOLN CTRL func")
  field (FLNK, "MGNT:LI29:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI29:1:KICKFUNCGO"){
  field (DESC, "Process KICK CTRL func")
  field (FLNK, "MGNT:LI29:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI29:1:SEXTFUNCGO"){
  field (DESC, "Process SEXT CTRL func")
  field (FLNK, "MGNT:LI29:1:CTRLCLEAR")
}




#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LI29:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "LGPS:LI29:2:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LI29:2:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LI29:2:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LI29:2:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LI29:2:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LI29:2:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LI29:2:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LI29:2:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LI29:2:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LI29:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LI29:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LI29:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LI29:2:EDES.PROC PP")
    field(LNK2, "LGPS:LI29:2:EACT.PROC PP")
    field(LNK3, "LGPS:LI29:2:EERR.DISA PP")
    field(LNK4, "LGPS:LI29:2:ECON.PROC PP")
    field(LNK5, "LGPS:LI29:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:LI29:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:LI29:2:BLEM.PROC PP")
    field(LNK8, "LGPS:LI29:2:BMOD.PROC PP")
    field(LNK9, "LGPS:LI29:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LI29:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LI29:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LI29:2:BMAX")
  field(DOL2, "LGPS:LI29:2:BMAX")
  field(DOL3, "LGPS:LI29:2:BMAX")
  field(DOL4, "LGPS:LI29:2:BMIN")
  field(DOL5, "LGPS:LI29:2:BMIN")
  field(DOL6, "LGPS:LI29:2:BMIN")
  field(LNK1, "LGPS:LI29:2:BMAGX.HOPR")
  field(LNK2, "LGPS:LI29:2:BMAGY.HOPR")
  field(LNK3, "LGPS:LI29:2:BLEM.HOPR")
  field(LNK4, "LGPS:LI29:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LI29:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LI29:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LI29:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LI29:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LI29:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LI29:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LI29:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI29:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI29:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI29:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI29:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI29:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LI29:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LI29:2:EDES NPP MS")
  field(INPB, "LGPS:LI29:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI29:201:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI29:201:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI29:201:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI29:201:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI29:201:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI29:201:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI29:201:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI29:201:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI29:201:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI29:201:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI29:201:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI29:201:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI29:201:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI29:201:EDES.PROC PP")
    field(LNK2, "QUAD:LI29:201:EACT.PROC PP")
    field(LNK3, "QUAD:LI29:201:EERR.DISA PP")
    field(LNK4, "QUAD:LI29:201:ECON.PROC PP")
    field(LNK5, "QUAD:LI29:201:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI29:201:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI29:201:BLEM.PROC PP")
    field(LNK8, "QUAD:LI29:201:BMOD.PROC PP")
    field(LNK9, "QUAD:LI29:201:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI29:201:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI29:201:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI29:201:BMAX")
  field(DOL2, "QUAD:LI29:201:BMAX")
  field(DOL3, "QUAD:LI29:201:BMAX")
  field(DOL4, "QUAD:LI29:201:BMIN")
  field(DOL5, "QUAD:LI29:201:BMIN")
  field(DOL6, "QUAD:LI29:201:BMIN")
  field(LNK1, "QUAD:LI29:201:BMAGX.HOPR")
  field(LNK2, "QUAD:LI29:201:BMAGY.HOPR")
  field(LNK3, "QUAD:LI29:201:BLEM.HOPR")
  field(LNK4, "QUAD:LI29:201:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI29:201:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI29:201:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:201:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:201:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI29:201:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI29:201:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI29:201:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:201:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:201:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:201:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:201:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:201:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI29:201:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI29:201:EDES NPP MS")
  field(INPB, "QUAD:LI29:201:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI29:301:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI29:301:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI29:301:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI29:301:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI29:301:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI29:301:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI29:301:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI29:301:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI29:301:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI29:301:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI29:301:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI29:301:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI29:301:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI29:301:EDES.PROC PP")
    field(LNK2, "QUAD:LI29:301:EACT.PROC PP")
    field(LNK3, "QUAD:LI29:301:EERR.DISA PP")
    field(LNK4, "QUAD:LI29:301:ECON.PROC PP")
    field(LNK5, "QUAD:LI29:301:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI29:301:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI29:301:BLEM.PROC PP")
    field(LNK8, "QUAD:LI29:301:BMOD.PROC PP")
    field(LNK9, "QUAD:LI29:301:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI29:301:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI29:301:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI29:301:BMAX")
  field(DOL2, "QUAD:LI29:301:BMAX")
  field(DOL3, "QUAD:LI29:301:BMAX")
  field(DOL4, "QUAD:LI29:301:BMIN")
  field(DOL5, "QUAD:LI29:301:BMIN")
  field(DOL6, "QUAD:LI29:301:BMIN")
  field(LNK1, "QUAD:LI29:301:BMAGX.HOPR")
  field(LNK2, "QUAD:LI29:301:BMAGY.HOPR")
  field(LNK3, "QUAD:LI29:301:BLEM.HOPR")
  field(LNK4, "QUAD:LI29:301:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI29:301:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI29:301:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:301:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:301:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI29:301:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI29:301:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI29:301:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:301:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:301:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:301:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:301:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:301:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI29:301:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI29:301:EDES NPP MS")
  field(INPB, "QUAD:LI29:301:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI29:401:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI29:401:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI29:401:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI29:401:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI29:401:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI29:401:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI29:401:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI29:401:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI29:401:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI29:401:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI29:401:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI29:401:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI29:401:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI29:401:EDES.PROC PP")
    field(LNK2, "QUAD:LI29:401:EACT.PROC PP")
    field(LNK3, "QUAD:LI29:401:EERR.DISA PP")
    field(LNK4, "QUAD:LI29:401:ECON.PROC PP")
    field(LNK5, "QUAD:LI29:401:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI29:401:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI29:401:BLEM.PROC PP")
    field(LNK8, "QUAD:LI29:401:BMOD.PROC PP")
    field(LNK9, "QUAD:LI29:401:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI29:401:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI29:401:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI29:401:BMAX")
  field(DOL2, "QUAD:LI29:401:BMAX")
  field(DOL3, "QUAD:LI29:401:BMAX")
  field(DOL4, "QUAD:LI29:401:BMIN")
  field(DOL5, "QUAD:LI29:401:BMIN")
  field(DOL6, "QUAD:LI29:401:BMIN")
  field(LNK1, "QUAD:LI29:401:BMAGX.HOPR")
  field(LNK2, "QUAD:LI29:401:BMAGY.HOPR")
  field(LNK3, "QUAD:LI29:401:BLEM.HOPR")
  field(LNK4, "QUAD:LI29:401:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI29:401:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI29:401:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:401:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:401:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI29:401:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI29:401:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI29:401:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:401:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:401:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:401:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:401:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:401:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI29:401:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI29:401:EDES NPP MS")
  field(INPB, "QUAD:LI29:401:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI29:501:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI29:501:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI29:501:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI29:501:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI29:501:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI29:501:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI29:501:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI29:501:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI29:501:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI29:501:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI29:501:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI29:501:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI29:501:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI29:501:EDES.PROC PP")
    field(LNK2, "QUAD:LI29:501:EACT.PROC PP")
    field(LNK3, "QUAD:LI29:501:EERR.DISA PP")
    field(LNK4, "QUAD:LI29:501:ECON.PROC PP")
    field(LNK5, "QUAD:LI29:501:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI29:501:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI29:501:BLEM.PROC PP")
    field(LNK8, "QUAD:LI29:501:BMOD.PROC PP")
    field(LNK9, "QUAD:LI29:501:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI29:501:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI29:501:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI29:501:BMAX")
  field(DOL2, "QUAD:LI29:501:BMAX")
  field(DOL3, "QUAD:LI29:501:BMAX")
  field(DOL4, "QUAD:LI29:501:BMIN")
  field(DOL5, "QUAD:LI29:501:BMIN")
  field(DOL6, "QUAD:LI29:501:BMIN")
  field(LNK1, "QUAD:LI29:501:BMAGX.HOPR")
  field(LNK2, "QUAD:LI29:501:BMAGY.HOPR")
  field(LNK3, "QUAD:LI29:501:BLEM.HOPR")
  field(LNK4, "QUAD:LI29:501:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI29:501:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI29:501:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:501:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:501:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI29:501:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI29:501:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI29:501:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:501:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:501:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:501:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:501:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:501:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI29:501:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI29:501:EDES NPP MS")
  field(INPB, "QUAD:LI29:501:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI29:601:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI29:601:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI29:601:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI29:601:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI29:601:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI29:601:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI29:601:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI29:601:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI29:601:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI29:601:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI29:601:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI29:601:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI29:601:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI29:601:EDES.PROC PP")
    field(LNK2, "QUAD:LI29:601:EACT.PROC PP")
    field(LNK3, "QUAD:LI29:601:EERR.DISA PP")
    field(LNK4, "QUAD:LI29:601:ECON.PROC PP")
    field(LNK5, "QUAD:LI29:601:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI29:601:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI29:601:BLEM.PROC PP")
    field(LNK8, "QUAD:LI29:601:BMOD.PROC PP")
    field(LNK9, "QUAD:LI29:601:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI29:601:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI29:601:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI29:601:BMAX")
  field(DOL2, "QUAD:LI29:601:BMAX")
  field(DOL3, "QUAD:LI29:601:BMAX")
  field(DOL4, "QUAD:LI29:601:BMIN")
  field(DOL5, "QUAD:LI29:601:BMIN")
  field(DOL6, "QUAD:LI29:601:BMIN")
  field(LNK1, "QUAD:LI29:601:BMAGX.HOPR")
  field(LNK2, "QUAD:LI29:601:BMAGY.HOPR")
  field(LNK3, "QUAD:LI29:601:BLEM.HOPR")
  field(LNK4, "QUAD:LI29:601:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI29:601:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI29:601:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:601:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:601:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI29:601:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI29:601:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI29:601:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:601:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:601:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:601:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:601:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:601:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI29:601:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI29:601:EDES NPP MS")
  field(INPB, "QUAD:LI29:601:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI29:701:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI29:701:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI29:701:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI29:701:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI29:701:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI29:701:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI29:701:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI29:701:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI29:701:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI29:701:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI29:701:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI29:701:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI29:701:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI29:701:EDES.PROC PP")
    field(LNK2, "QUAD:LI29:701:EACT.PROC PP")
    field(LNK3, "QUAD:LI29:701:EERR.DISA PP")
    field(LNK4, "QUAD:LI29:701:ECON.PROC PP")
    field(LNK5, "QUAD:LI29:701:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI29:701:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI29:701:BLEM.PROC PP")
    field(LNK8, "QUAD:LI29:701:BMOD.PROC PP")
    field(LNK9, "QUAD:LI29:701:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI29:701:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI29:701:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI29:701:BMAX")
  field(DOL2, "QUAD:LI29:701:BMAX")
  field(DOL3, "QUAD:LI29:701:BMAX")
  field(DOL4, "QUAD:LI29:701:BMIN")
  field(DOL5, "QUAD:LI29:701:BMIN")
  field(DOL6, "QUAD:LI29:701:BMIN")
  field(LNK1, "QUAD:LI29:701:BMAGX.HOPR")
  field(LNK2, "QUAD:LI29:701:BMAGY.HOPR")
  field(LNK3, "QUAD:LI29:701:BLEM.HOPR")
  field(LNK4, "QUAD:LI29:701:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI29:701:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI29:701:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:701:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:701:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI29:701:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI29:701:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI29:701:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:701:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:701:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:701:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:701:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:701:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI29:701:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI29:701:EDES NPP MS")
  field(INPB, "QUAD:LI29:701:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI29:801:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI29:801:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI29:801:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI29:801:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI29:801:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI29:801:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI29:801:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI29:801:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI29:801:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI29:801:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI29:801:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI29:801:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI29:801:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI29:801:EDES.PROC PP")
    field(LNK2, "QUAD:LI29:801:EACT.PROC PP")
    field(LNK3, "QUAD:LI29:801:EERR.DISA PP")
    field(LNK4, "QUAD:LI29:801:ECON.PROC PP")
    field(LNK5, "QUAD:LI29:801:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI29:801:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI29:801:BLEM.PROC PP")
    field(LNK8, "QUAD:LI29:801:BMOD.PROC PP")
    field(LNK9, "QUAD:LI29:801:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI29:801:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI29:801:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI29:801:BMAX")
  field(DOL2, "QUAD:LI29:801:BMAX")
  field(DOL3, "QUAD:LI29:801:BMAX")
  field(DOL4, "QUAD:LI29:801:BMIN")
  field(DOL5, "QUAD:LI29:801:BMIN")
  field(DOL6, "QUAD:LI29:801:BMIN")
  field(LNK1, "QUAD:LI29:801:BMAGX.HOPR")
  field(LNK2, "QUAD:LI29:801:BMAGY.HOPR")
  field(LNK3, "QUAD:LI29:801:BLEM.HOPR")
  field(LNK4, "QUAD:LI29:801:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI29:801:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI29:801:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:801:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:801:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI29:801:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI29:801:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI29:801:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:801:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:801:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:801:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:801:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:801:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI29:801:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI29:801:EDES NPP MS")
  field(INPB, "QUAD:LI29:801:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI29:901:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI29:901:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI29:901:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI29:901:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI29:901:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI29:901:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI29:901:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI29:901:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI29:901:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI29:901:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI29:901:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI29:901:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI29:901:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI29:901:EDES.PROC PP")
    field(LNK2, "QUAD:LI29:901:EACT.PROC PP")
    field(LNK3, "QUAD:LI29:901:EERR.DISA PP")
    field(LNK4, "QUAD:LI29:901:ECON.PROC PP")
    field(LNK5, "QUAD:LI29:901:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI29:901:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI29:901:BLEM.PROC PP")
    field(LNK8, "QUAD:LI29:901:BMOD.PROC PP")
    field(LNK9, "QUAD:LI29:901:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI29:901:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI29:901:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI29:901:BMAX")
  field(DOL2, "QUAD:LI29:901:BMAX")
  field(DOL3, "QUAD:LI29:901:BMAX")
  field(DOL4, "QUAD:LI29:901:BMIN")
  field(DOL5, "QUAD:LI29:901:BMIN")
  field(DOL6, "QUAD:LI29:901:BMIN")
  field(LNK1, "QUAD:LI29:901:BMAGX.HOPR")
  field(LNK2, "QUAD:LI29:901:BMAGY.HOPR")
  field(LNK3, "QUAD:LI29:901:BLEM.HOPR")
  field(LNK4, "QUAD:LI29:901:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI29:901:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI29:901:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:901:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI29:901:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI29:901:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI29:901:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI29:901:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:901:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:901:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:901:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI29:901:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI29:901:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI29:901:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI29:901:EDES NPP MS")
  field(INPB, "QUAD:LI29:901:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI29:202:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI29:202:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI29:202:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI29:202:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI29:202:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI29:202:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI29:202:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI29:202:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI29:202:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI29:202:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI29:202:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI29:202:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI29:202:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI29:202:EDES.PROC PP")
    field(LNK2, "XCOR:LI29:202:EACT.PROC PP")
    field(LNK3, "XCOR:LI29:202:EERR.DISA PP")
    field(LNK4, "XCOR:LI29:202:ECON.PROC PP")
    field(LNK5, "XCOR:LI29:202:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI29:202:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI29:202:BLEM.PROC PP")
    field(LNK8, "XCOR:LI29:202:BMOD.PROC PP")
    field(LNK9, "XCOR:LI29:202:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI29:202:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI29:202:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI29:202:BMAX")
  field(DOL2, "XCOR:LI29:202:BMAX")
  field(DOL3, "XCOR:LI29:202:BMAX")
  field(DOL4, "XCOR:LI29:202:BMIN")
  field(DOL5, "XCOR:LI29:202:BMIN")
  field(DOL6, "XCOR:LI29:202:BMIN")
  field(LNK1, "XCOR:LI29:202:BMAGX.HOPR")
  field(LNK2, "XCOR:LI29:202:BMAGY.HOPR")
  field(LNK3, "XCOR:LI29:202:BLEM.HOPR")
  field(LNK4, "XCOR:LI29:202:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI29:202:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI29:202:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:202:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:202:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI29:202:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI29:202:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI29:202:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:202:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:202:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:202:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:202:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:202:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI29:202:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI29:202:EDES NPP MS")
  field(INPB, "XCOR:LI29:202:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI29:302:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI29:302:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI29:302:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI29:302:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI29:302:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI29:302:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI29:302:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI29:302:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI29:302:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI29:302:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI29:302:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI29:302:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI29:302:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI29:302:EDES.PROC PP")
    field(LNK2, "XCOR:LI29:302:EACT.PROC PP")
    field(LNK3, "XCOR:LI29:302:EERR.DISA PP")
    field(LNK4, "XCOR:LI29:302:ECON.PROC PP")
    field(LNK5, "XCOR:LI29:302:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI29:302:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI29:302:BLEM.PROC PP")
    field(LNK8, "XCOR:LI29:302:BMOD.PROC PP")
    field(LNK9, "XCOR:LI29:302:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI29:302:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI29:302:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI29:302:BMAX")
  field(DOL2, "XCOR:LI29:302:BMAX")
  field(DOL3, "XCOR:LI29:302:BMAX")
  field(DOL4, "XCOR:LI29:302:BMIN")
  field(DOL5, "XCOR:LI29:302:BMIN")
  field(DOL6, "XCOR:LI29:302:BMIN")
  field(LNK1, "XCOR:LI29:302:BMAGX.HOPR")
  field(LNK2, "XCOR:LI29:302:BMAGY.HOPR")
  field(LNK3, "XCOR:LI29:302:BLEM.HOPR")
  field(LNK4, "XCOR:LI29:302:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI29:302:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI29:302:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:302:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:302:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI29:302:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI29:302:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI29:302:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:302:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:302:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:302:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:302:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:302:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI29:302:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI29:302:EDES NPP MS")
  field(INPB, "XCOR:LI29:302:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI29:402:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI29:402:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI29:402:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI29:402:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI29:402:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI29:402:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI29:402:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI29:402:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI29:402:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI29:402:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI29:402:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI29:402:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI29:402:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI29:402:EDES.PROC PP")
    field(LNK2, "XCOR:LI29:402:EACT.PROC PP")
    field(LNK3, "XCOR:LI29:402:EERR.DISA PP")
    field(LNK4, "XCOR:LI29:402:ECON.PROC PP")
    field(LNK5, "XCOR:LI29:402:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI29:402:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI29:402:BLEM.PROC PP")
    field(LNK8, "XCOR:LI29:402:BMOD.PROC PP")
    field(LNK9, "XCOR:LI29:402:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI29:402:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI29:402:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI29:402:BMAX")
  field(DOL2, "XCOR:LI29:402:BMAX")
  field(DOL3, "XCOR:LI29:402:BMAX")
  field(DOL4, "XCOR:LI29:402:BMIN")
  field(DOL5, "XCOR:LI29:402:BMIN")
  field(DOL6, "XCOR:LI29:402:BMIN")
  field(LNK1, "XCOR:LI29:402:BMAGX.HOPR")
  field(LNK2, "XCOR:LI29:402:BMAGY.HOPR")
  field(LNK3, "XCOR:LI29:402:BLEM.HOPR")
  field(LNK4, "XCOR:LI29:402:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI29:402:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI29:402:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:402:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:402:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI29:402:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI29:402:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI29:402:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:402:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:402:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:402:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:402:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:402:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI29:402:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI29:402:EDES NPP MS")
  field(INPB, "XCOR:LI29:402:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI29:502:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI29:502:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI29:502:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI29:502:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI29:502:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI29:502:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI29:502:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI29:502:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI29:502:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI29:502:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI29:502:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI29:502:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI29:502:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI29:502:EDES.PROC PP")
    field(LNK2, "XCOR:LI29:502:EACT.PROC PP")
    field(LNK3, "XCOR:LI29:502:EERR.DISA PP")
    field(LNK4, "XCOR:LI29:502:ECON.PROC PP")
    field(LNK5, "XCOR:LI29:502:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI29:502:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI29:502:BLEM.PROC PP")
    field(LNK8, "XCOR:LI29:502:BMOD.PROC PP")
    field(LNK9, "XCOR:LI29:502:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI29:502:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI29:502:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI29:502:BMAX")
  field(DOL2, "XCOR:LI29:502:BMAX")
  field(DOL3, "XCOR:LI29:502:BMAX")
  field(DOL4, "XCOR:LI29:502:BMIN")
  field(DOL5, "XCOR:LI29:502:BMIN")
  field(DOL6, "XCOR:LI29:502:BMIN")
  field(LNK1, "XCOR:LI29:502:BMAGX.HOPR")
  field(LNK2, "XCOR:LI29:502:BMAGY.HOPR")
  field(LNK3, "XCOR:LI29:502:BLEM.HOPR")
  field(LNK4, "XCOR:LI29:502:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI29:502:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI29:502:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:502:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:502:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI29:502:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI29:502:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI29:502:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:502:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:502:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:502:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:502:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:502:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI29:502:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI29:502:EDES NPP MS")
  field(INPB, "XCOR:LI29:502:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI29:602:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI29:602:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI29:602:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI29:602:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI29:602:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI29:602:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI29:602:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI29:602:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI29:602:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI29:602:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI29:602:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI29:602:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI29:602:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI29:602:EDES.PROC PP")
    field(LNK2, "XCOR:LI29:602:EACT.PROC PP")
    field(LNK3, "XCOR:LI29:602:EERR.DISA PP")
    field(LNK4, "XCOR:LI29:602:ECON.PROC PP")
    field(LNK5, "XCOR:LI29:602:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI29:602:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI29:602:BLEM.PROC PP")
    field(LNK8, "XCOR:LI29:602:BMOD.PROC PP")
    field(LNK9, "XCOR:LI29:602:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI29:602:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI29:602:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI29:602:BMAX")
  field(DOL2, "XCOR:LI29:602:BMAX")
  field(DOL3, "XCOR:LI29:602:BMAX")
  field(DOL4, "XCOR:LI29:602:BMIN")
  field(DOL5, "XCOR:LI29:602:BMIN")
  field(DOL6, "XCOR:LI29:602:BMIN")
  field(LNK1, "XCOR:LI29:602:BMAGX.HOPR")
  field(LNK2, "XCOR:LI29:602:BMAGY.HOPR")
  field(LNK3, "XCOR:LI29:602:BLEM.HOPR")
  field(LNK4, "XCOR:LI29:602:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI29:602:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI29:602:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:602:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:602:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI29:602:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI29:602:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI29:602:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:602:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:602:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:602:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:602:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:602:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI29:602:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI29:602:EDES NPP MS")
  field(INPB, "XCOR:LI29:602:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI29:702:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI29:702:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI29:702:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI29:702:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI29:702:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI29:702:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI29:702:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI29:702:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI29:702:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI29:702:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI29:702:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI29:702:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI29:702:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI29:702:EDES.PROC PP")
    field(LNK2, "XCOR:LI29:702:EACT.PROC PP")
    field(LNK3, "XCOR:LI29:702:EERR.DISA PP")
    field(LNK4, "XCOR:LI29:702:ECON.PROC PP")
    field(LNK5, "XCOR:LI29:702:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI29:702:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI29:702:BLEM.PROC PP")
    field(LNK8, "XCOR:LI29:702:BMOD.PROC PP")
    field(LNK9, "XCOR:LI29:702:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI29:702:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI29:702:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI29:702:BMAX")
  field(DOL2, "XCOR:LI29:702:BMAX")
  field(DOL3, "XCOR:LI29:702:BMAX")
  field(DOL4, "XCOR:LI29:702:BMIN")
  field(DOL5, "XCOR:LI29:702:BMIN")
  field(DOL6, "XCOR:LI29:702:BMIN")
  field(LNK1, "XCOR:LI29:702:BMAGX.HOPR")
  field(LNK2, "XCOR:LI29:702:BMAGY.HOPR")
  field(LNK3, "XCOR:LI29:702:BLEM.HOPR")
  field(LNK4, "XCOR:LI29:702:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI29:702:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI29:702:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:702:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:702:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI29:702:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI29:702:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI29:702:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:702:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:702:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:702:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:702:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:702:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI29:702:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI29:702:EDES NPP MS")
  field(INPB, "XCOR:LI29:702:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI29:802:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI29:802:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI29:802:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI29:802:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI29:802:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI29:802:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI29:802:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI29:802:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI29:802:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI29:802:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI29:802:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI29:802:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI29:802:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI29:802:EDES.PROC PP")
    field(LNK2, "XCOR:LI29:802:EACT.PROC PP")
    field(LNK3, "XCOR:LI29:802:EERR.DISA PP")
    field(LNK4, "XCOR:LI29:802:ECON.PROC PP")
    field(LNK5, "XCOR:LI29:802:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI29:802:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI29:802:BLEM.PROC PP")
    field(LNK8, "XCOR:LI29:802:BMOD.PROC PP")
    field(LNK9, "XCOR:LI29:802:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI29:802:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI29:802:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI29:802:BMAX")
  field(DOL2, "XCOR:LI29:802:BMAX")
  field(DOL3, "XCOR:LI29:802:BMAX")
  field(DOL4, "XCOR:LI29:802:BMIN")
  field(DOL5, "XCOR:LI29:802:BMIN")
  field(DOL6, "XCOR:LI29:802:BMIN")
  field(LNK1, "XCOR:LI29:802:BMAGX.HOPR")
  field(LNK2, "XCOR:LI29:802:BMAGY.HOPR")
  field(LNK3, "XCOR:LI29:802:BLEM.HOPR")
  field(LNK4, "XCOR:LI29:802:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI29:802:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI29:802:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:802:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:802:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI29:802:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI29:802:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI29:802:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:802:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:802:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:802:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:802:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:802:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI29:802:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI29:802:EDES NPP MS")
  field(INPB, "XCOR:LI29:802:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI29:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI29:900:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI29:900:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI29:900:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI29:900:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI29:900:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI29:900:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI29:900:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI29:900:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI29:900:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI29:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI29:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI29:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI29:900:EDES.PROC PP")
    field(LNK2, "XCOR:LI29:900:EACT.PROC PP")
    field(LNK3, "XCOR:LI29:900:EERR.DISA PP")
    field(LNK4, "XCOR:LI29:900:ECON.PROC PP")
    field(LNK5, "XCOR:LI29:900:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI29:900:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI29:900:BLEM.PROC PP")
    field(LNK8, "XCOR:LI29:900:BMOD.PROC PP")
    field(LNK9, "XCOR:LI29:900:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI29:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI29:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI29:900:BMAX")
  field(DOL2, "XCOR:LI29:900:BMAX")
  field(DOL3, "XCOR:LI29:900:BMAX")
  field(DOL4, "XCOR:LI29:900:BMIN")
  field(DOL5, "XCOR:LI29:900:BMIN")
  field(DOL6, "XCOR:LI29:900:BMIN")
  field(LNK1, "XCOR:LI29:900:BMAGX.HOPR")
  field(LNK2, "XCOR:LI29:900:BMAGY.HOPR")
  field(LNK3, "XCOR:LI29:900:BLEM.HOPR")
  field(LNK4, "XCOR:LI29:900:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI29:900:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI29:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI29:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI29:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI29:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI29:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI29:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI29:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI29:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI29:900:EDES NPP MS")
  field(INPB, "XCOR:LI29:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI29:203:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI29:203:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI29:203:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI29:203:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI29:203:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI29:203:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI29:203:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI29:203:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI29:203:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI29:203:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI29:203:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI29:203:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI29:203:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI29:203:EDES.PROC PP")
    field(LNK2, "YCOR:LI29:203:EACT.PROC PP")
    field(LNK3, "YCOR:LI29:203:EERR.DISA PP")
    field(LNK4, "YCOR:LI29:203:ECON.PROC PP")
    field(LNK5, "YCOR:LI29:203:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI29:203:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI29:203:BLEM.PROC PP")
    field(LNK8, "YCOR:LI29:203:BMOD.PROC PP")
    field(LNK9, "YCOR:LI29:203:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI29:203:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI29:203:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI29:203:BMAX")
  field(DOL2, "YCOR:LI29:203:BMAX")
  field(DOL3, "YCOR:LI29:203:BMAX")
  field(DOL4, "YCOR:LI29:203:BMIN")
  field(DOL5, "YCOR:LI29:203:BMIN")
  field(DOL6, "YCOR:LI29:203:BMIN")
  field(LNK1, "YCOR:LI29:203:BMAGX.HOPR")
  field(LNK2, "YCOR:LI29:203:BMAGY.HOPR")
  field(LNK3, "YCOR:LI29:203:BLEM.HOPR")
  field(LNK4, "YCOR:LI29:203:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI29:203:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI29:203:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:203:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:203:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI29:203:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI29:203:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI29:203:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:203:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:203:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:203:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:203:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:203:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI29:203:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI29:203:EDES NPP MS")
  field(INPB, "YCOR:LI29:203:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI29:303:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI29:303:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI29:303:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI29:303:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI29:303:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI29:303:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI29:303:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI29:303:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI29:303:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI29:303:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI29:303:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI29:303:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI29:303:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI29:303:EDES.PROC PP")
    field(LNK2, "YCOR:LI29:303:EACT.PROC PP")
    field(LNK3, "YCOR:LI29:303:EERR.DISA PP")
    field(LNK4, "YCOR:LI29:303:ECON.PROC PP")
    field(LNK5, "YCOR:LI29:303:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI29:303:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI29:303:BLEM.PROC PP")
    field(LNK8, "YCOR:LI29:303:BMOD.PROC PP")
    field(LNK9, "YCOR:LI29:303:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI29:303:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI29:303:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI29:303:BMAX")
  field(DOL2, "YCOR:LI29:303:BMAX")
  field(DOL3, "YCOR:LI29:303:BMAX")
  field(DOL4, "YCOR:LI29:303:BMIN")
  field(DOL5, "YCOR:LI29:303:BMIN")
  field(DOL6, "YCOR:LI29:303:BMIN")
  field(LNK1, "YCOR:LI29:303:BMAGX.HOPR")
  field(LNK2, "YCOR:LI29:303:BMAGY.HOPR")
  field(LNK3, "YCOR:LI29:303:BLEM.HOPR")
  field(LNK4, "YCOR:LI29:303:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI29:303:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI29:303:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:303:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:303:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI29:303:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI29:303:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI29:303:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:303:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:303:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:303:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:303:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:303:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI29:303:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI29:303:EDES NPP MS")
  field(INPB, "YCOR:LI29:303:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI29:403:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI29:403:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI29:403:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI29:403:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI29:403:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI29:403:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI29:403:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI29:403:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI29:403:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI29:403:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI29:403:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI29:403:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI29:403:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI29:403:EDES.PROC PP")
    field(LNK2, "YCOR:LI29:403:EACT.PROC PP")
    field(LNK3, "YCOR:LI29:403:EERR.DISA PP")
    field(LNK4, "YCOR:LI29:403:ECON.PROC PP")
    field(LNK5, "YCOR:LI29:403:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI29:403:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI29:403:BLEM.PROC PP")
    field(LNK8, "YCOR:LI29:403:BMOD.PROC PP")
    field(LNK9, "YCOR:LI29:403:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI29:403:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI29:403:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI29:403:BMAX")
  field(DOL2, "YCOR:LI29:403:BMAX")
  field(DOL3, "YCOR:LI29:403:BMAX")
  field(DOL4, "YCOR:LI29:403:BMIN")
  field(DOL5, "YCOR:LI29:403:BMIN")
  field(DOL6, "YCOR:LI29:403:BMIN")
  field(LNK1, "YCOR:LI29:403:BMAGX.HOPR")
  field(LNK2, "YCOR:LI29:403:BMAGY.HOPR")
  field(LNK3, "YCOR:LI29:403:BLEM.HOPR")
  field(LNK4, "YCOR:LI29:403:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI29:403:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI29:403:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:403:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:403:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI29:403:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI29:403:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI29:403:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:403:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:403:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:403:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:403:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:403:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI29:403:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI29:403:EDES NPP MS")
  field(INPB, "YCOR:LI29:403:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI29:503:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI29:503:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI29:503:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI29:503:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI29:503:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI29:503:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI29:503:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI29:503:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI29:503:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI29:503:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI29:503:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI29:503:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI29:503:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI29:503:EDES.PROC PP")
    field(LNK2, "YCOR:LI29:503:EACT.PROC PP")
    field(LNK3, "YCOR:LI29:503:EERR.DISA PP")
    field(LNK4, "YCOR:LI29:503:ECON.PROC PP")
    field(LNK5, "YCOR:LI29:503:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI29:503:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI29:503:BLEM.PROC PP")
    field(LNK8, "YCOR:LI29:503:BMOD.PROC PP")
    field(LNK9, "YCOR:LI29:503:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI29:503:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI29:503:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI29:503:BMAX")
  field(DOL2, "YCOR:LI29:503:BMAX")
  field(DOL3, "YCOR:LI29:503:BMAX")
  field(DOL4, "YCOR:LI29:503:BMIN")
  field(DOL5, "YCOR:LI29:503:BMIN")
  field(DOL6, "YCOR:LI29:503:BMIN")
  field(LNK1, "YCOR:LI29:503:BMAGX.HOPR")
  field(LNK2, "YCOR:LI29:503:BMAGY.HOPR")
  field(LNK3, "YCOR:LI29:503:BLEM.HOPR")
  field(LNK4, "YCOR:LI29:503:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI29:503:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI29:503:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:503:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:503:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI29:503:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI29:503:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI29:503:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:503:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:503:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:503:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:503:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:503:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI29:503:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI29:503:EDES NPP MS")
  field(INPB, "YCOR:LI29:503:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI29:603:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI29:603:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI29:603:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI29:603:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI29:603:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI29:603:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI29:603:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI29:603:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI29:603:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI29:603:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI29:603:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI29:603:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI29:603:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI29:603:EDES.PROC PP")
    field(LNK2, "YCOR:LI29:603:EACT.PROC PP")
    field(LNK3, "YCOR:LI29:603:EERR.DISA PP")
    field(LNK4, "YCOR:LI29:603:ECON.PROC PP")
    field(LNK5, "YCOR:LI29:603:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI29:603:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI29:603:BLEM.PROC PP")
    field(LNK8, "YCOR:LI29:603:BMOD.PROC PP")
    field(LNK9, "YCOR:LI29:603:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI29:603:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI29:603:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI29:603:BMAX")
  field(DOL2, "YCOR:LI29:603:BMAX")
  field(DOL3, "YCOR:LI29:603:BMAX")
  field(DOL4, "YCOR:LI29:603:BMIN")
  field(DOL5, "YCOR:LI29:603:BMIN")
  field(DOL6, "YCOR:LI29:603:BMIN")
  field(LNK1, "YCOR:LI29:603:BMAGX.HOPR")
  field(LNK2, "YCOR:LI29:603:BMAGY.HOPR")
  field(LNK3, "YCOR:LI29:603:BLEM.HOPR")
  field(LNK4, "YCOR:LI29:603:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI29:603:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI29:603:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:603:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:603:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI29:603:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI29:603:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI29:603:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:603:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:603:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:603:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:603:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:603:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI29:603:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI29:603:EDES NPP MS")
  field(INPB, "YCOR:LI29:603:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI29:703:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI29:703:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI29:703:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI29:703:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI29:703:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI29:703:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI29:703:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI29:703:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI29:703:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI29:703:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI29:703:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI29:703:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI29:703:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI29:703:EDES.PROC PP")
    field(LNK2, "YCOR:LI29:703:EACT.PROC PP")
    field(LNK3, "YCOR:LI29:703:EERR.DISA PP")
    field(LNK4, "YCOR:LI29:703:ECON.PROC PP")
    field(LNK5, "YCOR:LI29:703:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI29:703:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI29:703:BLEM.PROC PP")
    field(LNK8, "YCOR:LI29:703:BMOD.PROC PP")
    field(LNK9, "YCOR:LI29:703:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI29:703:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI29:703:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI29:703:BMAX")
  field(DOL2, "YCOR:LI29:703:BMAX")
  field(DOL3, "YCOR:LI29:703:BMAX")
  field(DOL4, "YCOR:LI29:703:BMIN")
  field(DOL5, "YCOR:LI29:703:BMIN")
  field(DOL6, "YCOR:LI29:703:BMIN")
  field(LNK1, "YCOR:LI29:703:BMAGX.HOPR")
  field(LNK2, "YCOR:LI29:703:BMAGY.HOPR")
  field(LNK3, "YCOR:LI29:703:BLEM.HOPR")
  field(LNK4, "YCOR:LI29:703:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI29:703:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI29:703:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:703:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:703:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI29:703:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI29:703:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI29:703:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:703:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:703:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:703:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:703:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:703:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI29:703:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI29:703:EDES NPP MS")
  field(INPB, "YCOR:LI29:703:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI29:803:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI29:803:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI29:803:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI29:803:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI29:803:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI29:803:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI29:803:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI29:803:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI29:803:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI29:803:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI29:803:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI29:803:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI29:803:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI29:803:EDES.PROC PP")
    field(LNK2, "YCOR:LI29:803:EACT.PROC PP")
    field(LNK3, "YCOR:LI29:803:EERR.DISA PP")
    field(LNK4, "YCOR:LI29:803:ECON.PROC PP")
    field(LNK5, "YCOR:LI29:803:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI29:803:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI29:803:BLEM.PROC PP")
    field(LNK8, "YCOR:LI29:803:BMOD.PROC PP")
    field(LNK9, "YCOR:LI29:803:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI29:803:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI29:803:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI29:803:BMAX")
  field(DOL2, "YCOR:LI29:803:BMAX")
  field(DOL3, "YCOR:LI29:803:BMAX")
  field(DOL4, "YCOR:LI29:803:BMIN")
  field(DOL5, "YCOR:LI29:803:BMIN")
  field(DOL6, "YCOR:LI29:803:BMIN")
  field(LNK1, "YCOR:LI29:803:BMAGX.HOPR")
  field(LNK2, "YCOR:LI29:803:BMAGY.HOPR")
  field(LNK3, "YCOR:LI29:803:BLEM.HOPR")
  field(LNK4, "YCOR:LI29:803:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI29:803:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI29:803:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:803:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:803:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI29:803:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI29:803:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI29:803:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:803:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:803:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:803:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:803:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:803:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI29:803:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI29:803:EDES NPP MS")
  field(INPB, "YCOR:LI29:803:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI29:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI29:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI29:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI29:900:FUNC CA PP")
  field(DOL2, "MGNT:LI29:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI29:900:FUNC CA PP")
  field(DOL3, "MGNT:LI29:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI29:900:FUNC CA PP")
  field(DOL4, "MGNT:LI29:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI29:900:FUNC CA PP")
  field(DOL5, "MGNT:LI29:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI29:900:FUNC CA PP")
  field(DOL6, "MGNT:LI29:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI29:900:FUNC CA PP")
  field(DOL7, "MGNT:LI29:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI29:900:FUNC CA PP")
  field(DOL8, "MGNT:LI29:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI29:900:FUNC CA PP")
  field(DOL9, "MGNT:LI29:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI29:900:FUNC CA PP")
  field(DOLA, "MGNT:LI29:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI29:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI29:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI29:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI29:900:EDES.PROC PP")
    field(LNK2, "YCOR:LI29:900:EACT.PROC PP")
    field(LNK3, "YCOR:LI29:900:EERR.DISA PP")
    field(LNK4, "YCOR:LI29:900:ECON.PROC PP")
    field(LNK5, "YCOR:LI29:900:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI29:900:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI29:900:BLEM.PROC PP")
    field(LNK8, "YCOR:LI29:900:BMOD.PROC PP")
    field(LNK9, "YCOR:LI29:900:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI29:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI29:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI29:900:BMAX")
  field(DOL2, "YCOR:LI29:900:BMAX")
  field(DOL3, "YCOR:LI29:900:BMAX")
  field(DOL4, "YCOR:LI29:900:BMIN")
  field(DOL5, "YCOR:LI29:900:BMIN")
  field(DOL6, "YCOR:LI29:900:BMIN")
  field(LNK1, "YCOR:LI29:900:BMAGX.HOPR")
  field(LNK2, "YCOR:LI29:900:BMAGY.HOPR")
  field(LNK3, "YCOR:LI29:900:BLEM.HOPR")
  field(LNK4, "YCOR:LI29:900:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI29:900:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI29:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI29:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI29:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI29:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI29:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI29:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI29:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI29:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI29:900:EDES NPP MS")
  field(INPB, "YCOR:LI29:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

record (seq, "MGNT:LI21:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:LI21:1:ALLKICKSSEL"){
 field(DOL1, "MGNT:LI21:1:ALLKICKS")
 field(DOL2, "MGNT:LI21:1:ALLKICKS")
 field(DOL3, "MGNT:LI21:1:ALLKICKS")
 field(DOL4, "MGNT:LI21:1:ALLKICKS")
 field(LNK1, "KICK:LI21:929:1:SELECT CPP NMS")
 field(LNK2, "KICK:LI21:929:2:SELECT CPP NMS")
 field(LNK3, "KICK:LI21:957:1:SELECT CPP NMS")
 field(LNK4, "KICK:LI21:957:2:SELECT CPP NMS")
}
record (seq, "MGNT:LI21:1:ALLSEXTSSEL"){
}

record(seq, "MGNT:LI21:1:ALLBENDSSEL") {
  field(LNK1, "BEND:LI21:231:SELECT CPP NMS")
  field(DOL1, "MGNT:LI21:1:ALLBENDS")
}

record(seq, "MGNT:LI21:1:ALLBTRMSSEL") {
  field(DOL1, "MGNT:LI21:1:ALLBTRMS")
  field(DOL2, "MGNT:LI21:1:ALLBTRMS")
  field(DOL3, "MGNT:LI21:1:ALLBTRMS")
  field(LNK1, "BTRM:LI21:215:SELECT CPP NMS")
  field(LNK2, "BTRM:LI21:241:SELECT CPP NMS")
  field(LNK3, "BTRM:LI21:261:SELECT CPP NMS")
}

record(seq, "MGNT:LI21:1:ALLLGPSSSEL") {
  field(DOL1, "MGNT:LI21:1:ALLLGPSS")
  field(DOL2, "MGNT:LI21:1:ALLLGPSS")
  field(LNK1, "LGPS:LI21:2:SELECT CPP NMS")
  field(LNK2, "LGPS:LI21:3:SELECT CPP NMS")
}

record(seq, "MGNT:LI21:1:ALLQUADSSEL") {
  field(DOL1, "MGNT:LI21:1:ALLQUADS")
  field(DOL2, "MGNT:LI21:1:ALLQUADS")
  field(DOL3, "MGNT:LI21:1:ALLQUADS")
  field(DOL4, "MGNT:LI21:1:ALLQUADS")
  field(DOL5, "MGNT:LI21:1:ALLQUADS")
  field(DOL6, "MGNT:LI21:1:ALLQUADS")
  field(DOL7, "MGNT:LI21:1:ALLQUADS")
  field(DOL8, "MGNT:LI21:1:ALLQUADS")
  field(DOL9, "MGNT:LI21:1:ALLQUADS")
  field(LNK1, "QUAD:LI21:131:SELECT CPP NMS")
  field(LNK2, "QUAD:LI21:161:SELECT CPP NMS")
  field(LNK3, "QUAD:LI21:315:SELECT CPP NMS")
  field(LNK4, "QUAD:LI21:335:SELECT CPP NMS")
  field(LNK5, "QUAD:LI21:221:SELECT CPP NMS")
  field(LNK6, "QUAD:LI21:251:SELECT CPP NMS")
  field(LNK7, "QUAD:LI21:211:SELECT CPP NMS")
  field(LNK8, "QUAD:LI21:271:SELECT CPP NMS")
  field(LNK9, "QUAD:LI21:278:SELECT CPP NMS")
  field(FLNK, "MGNT:LI21:1:ALLQUADSSEL2")
}

record(seq, "MGNT:LI21:1:ALLQUADSSEL2") {
  field(DOL1, "MGNT:LI21:1:ALLQUADS")
  field(DOL2, "MGNT:LI21:1:ALLQUADS")
  field(DOL3, "MGNT:LI21:1:ALLQUADS")
  field(DOL4, "MGNT:LI21:1:ALLQUADS")
  field(DOL5, "MGNT:LI21:1:ALLQUADS")
  field(DOL6, "MGNT:LI21:1:ALLQUADS")
  field(DOL7, "MGNT:LI21:1:ALLQUADS")
  field(DOL8, "MGNT:LI21:1:ALLQUADS")
  field(DOL9, "MGNT:LI21:1:ALLQUADS")
  field(LNK1, "QUAD:LI21:243:SELECT CPP NMS")
  field(LNK2, "QUAD:LI21:201:SELECT CPP NMS")
  field(LNK3, "QUAD:LI21:301:SELECT CPP NMS")
  field(LNK4, "QUAD:LI21:401:SELECT CPP NMS")
  field(LNK5, "QUAD:LI21:501:SELECT CPP NMS")
  field(LNK6, "QUAD:LI21:601:SELECT CPP NMS")
  field(LNK7, "QUAD:LI21:701:SELECT CPP NMS")
  field(LNK8, "QUAD:LI21:801:SELECT CPP NMS")
  field(LNK9, "QUAD:LI21:901:SELECT CPP NMS")
}

record(seq, "MGNT:LI21:1:ALLXCORSSEL") {
  field(DOL1, "MGNT:LI21:1:ALLXCORS")
  field(LNK1, "XCOR:LI21:101:SELECT CPP NMS")
  field(LNK2, "XCOR:LI21:135:SELECT CPP NMS")
  field(LNK3, "XCOR:LI21:165:SELECT CPP NMS")
  field(LNK4, "XCOR:LI21:191:SELECT CPP NMS")
  field(LNK5, "XCOR:LI21:275:SELECT CPP NMS")
  field(LNK6, "XCOR:LI21:302:SELECT CPP NMS")
  field(LNK7, "XCOR:LI21:325:SELECT CPP NMS")
  field(DOL2, "MGNT:LI21:1:ALLXCORS")
  field(DOL3, "MGNT:LI21:1:ALLXCORS")
  field(DOL4, "MGNT:LI21:1:ALLXCORS")
  field(DOL5, "MGNT:LI21:1:ALLXCORS")
  field(DOL6, "MGNT:LI21:1:ALLXCORS")
  field(DOL7, "MGNT:LI21:1:ALLXCORS")
  field(FLNK, "MGNT:LI21:1:ALLXCORSSEL2")
}

record(seq, "MGNT:LI21:1:ALLXCORSSEL2") {
  field(DOL1, "MGNT:LI21:1:ALLXCORS")
  field(DOL2, "MGNT:LI21:1:ALLXCORS")
  field(DOL3, "MGNT:LI21:1:ALLXCORS")
  field(DOL4, "MGNT:LI21:1:ALLXCORS")
  field(DOL5, "MGNT:LI21:1:ALLXCORS")
  field(DOL6, "MGNT:LI21:1:ALLXCORS")
  field(DOL7, "MGNT:LI21:1:ALLXCORS")
  field(LNK1, "XCOR:LI21:175:SELECT CPP NMS")
  field(LNK2, "XCOR:LI21:402:SELECT CPP NMS")
  field(LNK3, "XCOR:LI21:502:SELECT CPP NMS")
  field(LNK4, "XCOR:LI21:602:SELECT CPP NMS")
  field(LNK5, "XCOR:LI21:702:SELECT CPP NMS")
  field(LNK6, "XCOR:LI21:802:SELECT CPP NMS")
  field(LNK7, "XCOR:LI21:900:SELECT CPP NMS")
}

record(seq, "MGNT:LI21:1:ALLYCORSSEL") {
  field(LNK1, "YCOR:LI21:102:SELECT CPP NMS")
  field(LNK2, "YCOR:LI21:136:SELECT CPP NMS")
  field(LNK3, "YCOR:LI21:166:SELECT CPP NMS")
  field(LNK4, "YCOR:LI21:192:SELECT CPP NMS")
  field(LNK5, "YCOR:LI21:276:SELECT CPP NMS")
  field(LNK6, "YCOR:LI21:303:SELECT CPP NMS")
  field(LNK7, "YCOR:LI21:325:SELECT CPP NMS")
  field(DOL1, "MGNT:LI21:1:ALLYCORS")
  field(DOL2, "MGNT:LI21:1:ALLYCORS")
  field(DOL3, "MGNT:LI21:1:ALLYCORS")
  field(DOL4, "MGNT:LI21:1:ALLYCORS")
  field(DOL5, "MGNT:LI21:1:ALLYCORS")
  field(DOL6, "MGNT:LI21:1:ALLYCORS")
  field(DOL7, "MGNT:LI21:1:ALLYCORS")
  field(FLNK, "MGNT:LI21:1:ALLYCORSSEL2")
}

record (seq, "MGNT:LI21:1:ALLYCORSSEL2"){
  field(DOL1, "MGNT:LI21:1:ALLYCORS")
  field(DOL2, "MGNT:LI21:1:ALLYCORS")
  field(DOL3, "MGNT:LI21:1:ALLYCORS")
  field(DOL4, "MGNT:LI21:1:ALLYCORS")
  field(DOL5, "MGNT:LI21:1:ALLYCORS")
  field(DOL6, "MGNT:LI21:1:ALLYCORS")
  field(DOL7, "MGNT:LI21:1:ALLYCORS")
  field(LNK1, "YCOR:LI21:174:SELECT CPP NMS")
  field(LNK2, "YCOR:LI21:403:SELECT CPP NMS")
  field(LNK3, "YCOR:LI21:503:SELECT CPP NMS")
  field(LNK4, "YCOR:LI21:603:SELECT CPP NMS")
  field(LNK5, "YCOR:LI21:703:SELECT CPP NMS")
  field(LNK6, "YCOR:LI21:803:SELECT CPP NMS")
  field(LNK7, "YCOR:LI21:900:SELECT CPP NMS")
}

record(seq, "MGNT:LI21:1:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(LNK1, "MGNT:LI21:1:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:LI21:1:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:LI21:1:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:LI21:1:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:LI21:1:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:LI21:1:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:LI21:1:LGPSFUNCGO.PROC")
  field(FLNK, "MGNT:LI21:1:ALLFUNCGO1")
}
record(seq, "MGNT:LI21:1:ALLFUNCGO1") {
  field(DESC, "Process CTRL func")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:LI21:1:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:LI21:1:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:LI21:1:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:LI21:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:LI21:1:CTRLCLEAR")
}

record(fanout, "MGNT:LI21:1:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(LNK1, "BEND:LI21:231:ALLFUNCGO")
  field(FLNK, "MGNT:LI21:1:CTRLCLEAR")
}

record(fanout, "MGNT:LI21:1:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(LNK1, "BTRM:LI21:215:ALLFUNCGO")
  field(LNK2, "BTRM:LI21:241:ALLFUNCGO")
  field(LNK3, "BTRM:LI21:261:ALLFUNCGO")
  field(FLNK, "MGNT:LI21:1:CTRLCLEAR")
}

record(fanout, "MGNT:LI21:1:QUADFUNCGO") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:LI21:131:ALLFUNCGO")
  field(LNK2, "QUAD:LI21:161:ALLFUNCGO")
  field(LNK3, "QUAD:LI21:315:ALLFUNCGO")
  field(LNK4, "QUAD:LI21:335:ALLFUNCGO")
  field(LNK5, "QUAD:LI21:221:ALLFUNCGO")
  field(LNK6, "QUAD:LI21:251:ALLFUNCGO")
  field(FLNK, "MGNT:LI21:1:QUADFUNCGO2")
}

record(fanout, "MGNT:LI21:1:QUADFUNCGO2") {
  field(DESC, "Process QUAD CTRL func2")
  field(LNK1, "QUAD:LI21:211:ALLFUNCGO")
  field(LNK2, "QUAD:LI21:271:ALLFUNCGO")
  field(LNK3, "QUAD:LI21:278:ALLFUNCGO")
  field(LNK4, "QUAD:LI21:243:ALLFUNCGO")
  field(LNK5, "QUAD:LI21:201:ALLFUNCGO")
  field(LNK6, "QUAD:LI21:301:ALLFUNCGO")
  field(FLNK, "MGNT:LI21:1:QUADFUNCGO3")
}

record(fanout, "MGNT:LI21:1:QUADFUNCGO3") {
  field(DESC, "Process QUAD CTRL func2")
  field(LNK1, "QUAD:LI21:401:ALLFUNCGO")
  field(LNK2, "QUAD:LI21:501:ALLFUNCGO")
  field(LNK3, "QUAD:LI21:601:ALLFUNCGO")
  field(LNK4, "QUAD:LI21:701:ALLFUNCGO")
  field(LNK5, "QUAD:LI21:801:ALLFUNCGO")
  field(LNK6, "QUAD:LI21:901:ALLFUNCGO")
  field(FLNK, "MGNT:LI21:1:CTRLCLEAR")
}

record(fanout, "MGNT:LI21:1:XCORFUNCGO") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:LI21:101:ALLFUNCGO")
  field(LNK2, "XCOR:LI21:135:ALLFUNCGO")
  field(LNK3, "XCOR:LI21:165:ALLFUNCGO")
  field(LNK4, "XCOR:LI21:191:ALLFUNCGO")
  field(LNK5, "XCOR:LI21:175:ALLFUNCGO")
  field(LNK6, "XCOR:LI21:275:ALLFUNCGO")
  field(FLNK, "MGNT:LI21:1:XCORFUNCGO2")
}

record(fanout, "MGNT:LI21:1:XCORFUNCGO2") {
  field(DESC, "Process XCOR CTRL func2")
  field(LNK1, "XCOR:LI21:302:ALLFUNCGO")
  field(LNK2, "XCOR:LI21:325:ALLFUNCGO")
  field(LNK3, "XCOR:LI21:402:ALLFUNCGO")
  field(LNK4, "XCOR:LI21:502:ALLFUNCGO")
  field(LNK5, "XCOR:LI21:602:ALLFUNCGO")
  field(LNK6, "XCOR:LI21:702:ALLFUNCGO")
  field(FLNK, "MGNT:LI21:1:XCORFUNCGO3")
}

record (fanout, "MGNT:LI21:1:XCORFUNCGO3") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:LI21:802:ALLFUNCGO")
  field(LNK2, "XCOR:LI21:900:ALLFUNCGO")
  field(FLNK, "MGNT:LI21:1:CTRLCLEAR")
}

record(fanout, "MGNT:LI21:1:YCORFUNCGO") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:LI21:102:ALLFUNCGO")
  field(LNK2, "YCOR:LI21:136:ALLFUNCGO")
  field(LNK3, "YCOR:LI21:166:ALLFUNCGO")
  field(LNK4, "YCOR:LI21:192:ALLFUNCGO")
  field(LNK5, "YCOR:LI21:276:ALLFUNCGO")
  field(LNK6, "YCOR:LI21:303:ALLFUNCGO")
  field(FLNK, "MGNT:LI21:1:YCORFUNCGO2")
}

record(fanout, "MGNT:LI21:1:YCORFUNCGO2") {
  field(DESC, "Process YCOR CTRL func2")
  field(LNK1, "YCOR:LI21:325:ALLFUNCGO")
  field(LNK2, "YCOR:LI21:174:ALLFUNCGO")
  field(LNK3, "YCOR:LI21:403:ALLFUNCGO")
  field(LNK4, "YCOR:LI21:503:ALLFUNCGO")
  field(LNK5, "YCOR:LI21:603:ALLFUNCGO")
  field(LNK6, "YCOR:LI21:703:ALLFUNCGO")
  field(FLNK, "MGNT:LI21:1:YCORFUNCGO3")
}

record (fanout, "MGNT:LI21:1:YCORFUNCGO3") {
  field(DESC, "Process YCOR CTRL func3")
  field(LNK1, "YCOR:LI21:803:ALLFUNCGO")
  field(LNK2, "YCOR:LI21:900:ALLFUNCGO")
  field(FLNK, "MGNT:LI21:1:CTRLCLEAR")
}

record(fanout, "MGNT:LI21:1:LGPSFUNCGO") {
  field(DESC, "Process LGPS CTRL func")
  field(LNK1, "LGPS:LI21:2:ALLFUNCGO")
  field(LNK2, "LGPS:LI21:3:ALLFUNCGO")
  field(FLNK, "MGNT:LI21:1:CTRLCLEAR")
}

record(fanout, "MGNT:LI21:1:SOLNFUNCGO") {
  field(DESC, "Process SOLN CTRL func")
  field(FLNK, "MGNT:LI21:1:CTRLCLEAR")
}
record(fanout, "MGNT:LI21:1:KICKFUNCGO") {
  field(DESC, "Process KICK CTRL func")
  field(LNK1, "KICK:LI21:929:1:ALLFUNCGO")
  field(LNK2, "KICK:LI21:929:2:ALLFUNCGO")
  field(LNK3, "KICK:LI21:957:1:ALLFUNCGO")
  field(LNK4, "KICK:LI21:957:2:ALLFUNCGO")
  field(FLNK, "MGNT:LI21:1:CTRLCLEAR")
}
record(fanout, "MGNT:LI21:1:SEXTFUNCGO") {
  field(DESC, "Process SEXT CTRL func")
  field(FLNK, "MGNT:LI21:1:CTRLCLEAR")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record (seq, "MGNT:LI22:1:ALLBENDSSEL"){
}
record (seq, "MGNT:LI22:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:LI22:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:LI22:1:ALLKICKSSEL"){
  field (DOL1, "MGNT:LI22:1:ALLKICKS")
  field (DOL2, "MGNT:LI22:1:ALLKICKS")
  field (DOL3, "MGNT:LI22:1:ALLKICKS")
  field (DOL4, "MGNT:LI22:1:ALLKICKS")
  field (LNK1, "KICK:LI22:929:1:SELECT CPP NMS")
  field (LNK2, "KICK:LI22:929:2:SELECT CPP NMS")
  field (LNK3, "KICK:LI22:957:1:SELECT CPP NMS")
  field (LNK4, "KICK:LI22:957:2:SELECT CPP NMS")
}
record (seq, "MGNT:LI22:1:ALLSEXTSSEL"){
}

record (seq, "MGNT:LI22:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:LI22:1:ALLXCORS")
  field (DOL2, "MGNT:LI22:1:ALLXCORS")
  field (DOL3, "MGNT:LI22:1:ALLXCORS")
  field (DOL4, "MGNT:LI22:1:ALLXCORS")
  field (DOL5, "MGNT:LI22:1:ALLXCORS")
  field (DOL6, "MGNT:LI22:1:ALLXCORS")
  field (DOL7, "MGNT:LI22:1:ALLXCORS")
  field (DOL8, "MGNT:LI22:1:ALLXCORS")
  field (LNK1, "XCOR:LI22:202:SELECT CPP NMS")
  field (LNK2, "XCOR:LI22:302:SELECT CPP NMS")
  field (LNK3, "XCOR:LI22:402:SELECT CPP NMS")
  field (LNK4, "XCOR:LI22:502:SELECT CPP NMS")
  field (LNK5, "XCOR:LI22:602:SELECT CPP NMS")
  field (LNK6, "XCOR:LI22:702:SELECT CPP NMS")
  field (LNK7, "XCOR:LI22:802:SELECT CPP NMS")
  field (LNK8, "XCOR:LI22:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI22:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:LI22:1:ALLYCORS")
  field (DOL2, "MGNT:LI22:1:ALLYCORS")
  field (DOL3, "MGNT:LI22:1:ALLYCORS")
  field (DOL4, "MGNT:LI22:1:ALLYCORS")
  field (DOL5, "MGNT:LI22:1:ALLYCORS")
  field (DOL6, "MGNT:LI22:1:ALLYCORS")
  field (DOL7, "MGNT:LI22:1:ALLYCORS")
  field (DOL8, "MGNT:LI22:1:ALLYCORS")
  field (LNK1, "YCOR:LI22:203:SELECT CPP NMS")
  field (LNK2, "YCOR:LI22:303:SELECT CPP NMS")
  field (LNK3, "YCOR:LI22:403:SELECT CPP NMS")
  field (LNK4, "YCOR:LI22:503:SELECT CPP NMS")
  field (LNK5, "YCOR:LI22:603:SELECT CPP NMS")
  field (LNK6, "YCOR:LI22:703:SELECT CPP NMS")
  field (LNK7, "YCOR:LI22:803:SELECT CPP NMS")
  field (LNK8, "YCOR:LI22:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI22:1:ALLLGPSSSEL"){
  field (DOL1, "MGNT:LI22:1:ALLLGPSS")
  field (LNK1, "LGPS:LI22:2:SELECT CPP NMS")
}

record (seq, "MGNT:LI22:1:ALLQUADSSEL"){
  field (DOL1, "MGNT:LI22:1:ALLQUADS")
  field (DOL2, "MGNT:LI22:1:ALLQUADS")
  field (DOL3, "MGNT:LI22:1:ALLQUADS")
  field (DOL4, "MGNT:LI22:1:ALLQUADS")
  field (DOL5, "MGNT:LI22:1:ALLQUADS")
  field (DOL6, "MGNT:LI22:1:ALLQUADS")
  field (DOL7, "MGNT:LI22:1:ALLQUADS")
  field (DOL8, "MGNT:LI22:1:ALLQUADS")
  field (LNK1, "QUAD:LI22:201:SELECT CPP NMS")
  field (LNK2, "QUAD:LI22:301:SELECT CPP NMS")
  field (LNK3, "QUAD:LI22:401:SELECT CPP NMS")
  field (LNK4, "QUAD:LI22:501:SELECT CPP NMS")
  field (LNK5, "QUAD:LI22:601:SELECT CPP NMS")
  field (LNK6, "QUAD:LI22:701:SELECT CPP NMS")
  field (LNK7, "QUAD:LI22:801:SELECT CPP NMS")
  field (LNK8, "QUAD:LI22:901:SELECT CPP NMS")
}

record (seq, "MGNT:LI22:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:LI22:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:LI22:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:LI22:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:LI22:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:LI22:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:LI22:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:LI22:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:LI22:1:ALLFUNCGO1")
}
record(seq, "MGNT:LI22:1:ALLFUNCGO1") {
  field(DESC, "Process CTRL func")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:LI22:1:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:LI22:1:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:LI22:1:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:LI22:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:LI22:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI22:1:QUADFUNCGO") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI22:201:ALLFUNCGO")
  field (LNK2, "QUAD:LI22:301:ALLFUNCGO")
  field (LNK3, "QUAD:LI22:401:ALLFUNCGO")
  field (LNK4, "QUAD:LI22:501:ALLFUNCGO")
  field (LNK5, "QUAD:LI22:601:ALLFUNCGO")
  field (LNK6, "QUAD:LI22:701:ALLFUNCGO")
  field (FLNK, "MGNT:LI22:1:QUADFUNCGO1")
}

record (fanout, "MGNT:LI22:1:QUADFUNCGO1") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI22:801:ALLFUNCGO")
  field (LNK2, "QUAD:LI22:901:ALLFUNCGO")
  field (FLNK, "MGNT:LI22:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI22:1:XCORFUNCGO") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI22:202:ALLFUNCGO")
  field (LNK2, "XCOR:LI22:302:ALLFUNCGO")
  field (LNK3, "XCOR:LI22:402:ALLFUNCGO")
  field (LNK4, "XCOR:LI22:502:ALLFUNCGO")
  field (LNK5, "XCOR:LI22:602:ALLFUNCGO")
  field (LNK6, "XCOR:LI22:702:ALLFUNCGO")
  field (FLNK, "MGNT:LI22:1:XCORFUNCGO1")
}

record (fanout, "MGNT:LI22:1:XCORFUNCGO1") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI22:802:ALLFUNCGO")
  field (LNK2, "XCOR:LI22:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI22:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI22:1:YCORFUNCGO") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI22:203:ALLFUNCGO")
  field (LNK2, "YCOR:LI22:303:ALLFUNCGO")
  field (LNK3, "YCOR:LI22:403:ALLFUNCGO")
  field (LNK4, "YCOR:LI22:503:ALLFUNCGO")
  field (LNK5, "YCOR:LI22:603:ALLFUNCGO")
  field (LNK6, "YCOR:LI22:703:ALLFUNCGO")
  field (FLNK, "MGNT:LI22:1:YCORFUNCGO1")
}

record (fanout, "MGNT:LI22:1:YCORFUNCGO1") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI22:803:ALLFUNCGO")
  field (LNK2, "YCOR:LI22:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI22:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI22:1:LGPSFUNCGO"){
  field (DESC, "Process LGPS CTRL func")
  field (LNK1, "LGPS:LI22:2:ALLFUNCGO")
  field (FLNK, "MGNT:LI22:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI22:1:BENDFUNCGO"){
  field (DESC, "Process BEND CTRL func")
  field (FLNK, "MGNT:LI22:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI22:1:BTRMFUNCGO"){
  field (DESC, "Process BTRM CTRL func")
  field (FLNK, "MGNT:LI22:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI22:1:SOLNFUNCGO"){
  field (DESC, "Process SOLN CTRL func")
  field (FLNK, "MGNT:LI22:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI22:1:KICKFUNCGO"){
  field (DESC, "Process KICK CTRL func")
  field (LNK1, "KICK:LI22:929:1:ALLFUNCGO")
  field (LNK2, "KICK:LI22:929:2:ALLFUNCGO")
  field (LNK3, "KICK:LI22:957:1:ALLFUNCGO")
  field (LNK4, "KICK:LI22:957:2:ALLFUNCGO")
  field (FLNK, "MGNT:LI22:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI22:1:SEXTFUNCGO"){
  field (DESC, "Process SEXT CTRL func")
  field (FLNK, "MGNT:LI22:1:CTRLCLEAR")
}

# End of file


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record (seq, "MGNT:LI24:1:ALLBENDSSEL"){
  field (LNK1, "BEND:LI24:790:SELECT PP NMS")
  field (DOL1, "MGNT:LI24:1:ALLBENDS")
}

record (seq, "MGNT:LI24:1:ALLBTRMSSEL"){
  field (DOL1, "MGNT:LI24:1:ALLBTRMS")
  field (DOL2, "MGNT:LI24:1:ALLBTRMS")
  field (DOL3, "MGNT:LI24:1:ALLBTRMS")
  field (LNK1, "BTRM:LI24:720:SELECT CPP NMS")
  field (LNK2, "BTRM:LI24:810:SELECT CPP NMS")
  field (LNK3, "BTRM:LI24:880:SELECT CPP NMS")
}

record (seq, "MGNT:LI24:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:LI24:1:ALLXCORS")
  field (DOL2, "MGNT:LI24:1:ALLXCORS")
  field (DOL3, "MGNT:LI24:1:ALLXCORS")
  field (DOL4, "MGNT:LI24:1:ALLXCORS")
  field (DOL5, "MGNT:LI24:1:ALLXCORS")
  field (DOL6, "MGNT:LI24:1:ALLXCORS")
  field (DOL7, "MGNT:LI24:1:ALLXCORS")
  field (LNK1, "XCOR:LI24:202:SELECT CPP NMS")
  field (LNK2, "XCOR:LI24:302:SELECT CPP NMS")
  field (LNK3, "XCOR:LI24:402:SELECT CPP NMS")
  field (LNK4, "XCOR:LI24:502:SELECT CPP NMS")
  field (LNK5, "XCOR:LI24:602:SELECT CPP NMS")
  field (LNK6, "XCOR:LI24:702:SELECT CPP NMS")
  field (LNK7, "XCOR:LI24:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI24:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:LI24:1:ALLYCORS")
  field (DOL2, "MGNT:LI24:1:ALLYCORS")
  field (DOL3, "MGNT:LI24:1:ALLYCORS")
  field (DOL4, "MGNT:LI24:1:ALLYCORS")
  field (DOL5, "MGNT:LI24:1:ALLYCORS")
  field (DOL6, "MGNT:LI24:1:ALLYCORS")
  field (DOL7, "MGNT:LI24:1:ALLYCORS")
  field (LNK1, "YCOR:LI24:203:SELECT CPP NMS")
  field (LNK2, "YCOR:LI24:303:SELECT CPP NMS")
  field (LNK3, "YCOR:LI24:403:SELECT CPP NMS")
  field (LNK4, "YCOR:LI24:503:SELECT CPP NMS")
  field (LNK5, "YCOR:LI24:603:SELECT CPP NMS")
  field (LNK6, "YCOR:LI24:703:SELECT CPP NMS")
  field (LNK7, "YCOR:LI24:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI24:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:LI24:1:ALLKICKSSEL"){
}
record (seq, "MGNT:LI24:1:ALLSEXTSSEL"){
}

record (seq, "MGNT:LI24:1:ALLLGPSSSEL"){
  field (DOL1, "MGNT:LI24:1:ALLLGPSS")
  field (DOL2, "MGNT:LI24:1:ALLLGPSS")
  field (LNK1, "LGPS:LI24:2:SELECT CPP NMS")
  field (LNK2, "LGPS:LI24:3:SELECT CPP NMS")
}

record (seq, "MGNT:LI24:1:ALLQUADSSEL"){
  field (DOL1, "MGNT:LI24:1:ALLQUADS")
  field (DOL2, "MGNT:LI24:1:ALLQUADS")
  field (DOL3, "MGNT:LI24:1:ALLQUADS")
  field (DOL4, "MGNT:LI24:1:ALLQUADS")
  field (DOL5, "MGNT:LI24:1:ALLQUADS")
  field (DOL6, "MGNT:LI24:1:ALLQUADS")
  field (DOL7, "MGNT:LI24:1:ALLQUADS")
  field (DOL8, "MGNT:LI24:1:ALLQUADS")
  field (DOL9, "MGNT:LI24:1:ALLQUADS")
  field (LNK1, "QUAD:LI24:201:SELECT CPP NMS")
  field (LNK2, "QUAD:LI24:301:SELECT CPP NMS")
  field (LNK3, "QUAD:LI24:401:SELECT CPP NMS")
  field (LNK4, "QUAD:LI24:501:SELECT CPP NMS")
  field (LNK5, "QUAD:LI24:601:SELECT CPP NMS")
  field (LNK6, "QUAD:LI24:701:SELECT CPP NMS")
  field (LNK7, "QUAD:LI24:713:SELECT CPP NMS")
  field (LNK8, "QUAD:LI24:740:SELECT CPP NMS")
  field (LNK9, "QUAD:LI24:860:SELECT CPP NMS")
  field (FLNK, "MGNT:LI24:1:ALLQUADSSEL2")
}

record (seq, "MGNT:LI24:1:ALLQUADSSEL2"){
  field (DOL1, "MGNT:LI24:1:ALLQUADS")
  field (DOL2, "MGNT:LI24:1:ALLQUADS")
  field (LNK1, "QUAD:LI24:892:SELECT CPP NMS")
  field (LNK2, "QUAD:LI24:901:SELECT CPP NMS")
}

record (seq, "MGNT:LI24:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (DOL8, "1")
  field (LNK1, "MGNT:LI24:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:LI24:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:LI24:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:LI24:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:LI24:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:LI24:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:LI24:1:LGPSFUNCGO.PROC")
  field (LNK8, "MGNT:LI24:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:LI24:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI24:1:BENDFUNCGO") {
  field (DESC, "Process BEND CTRL func")
  field (LNK1, "BEND:LI24:790:ALLFUNCGO")
  field (FLNK, "MGNT:LI24:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI24:1:BTRMFUNCGO") {
  field (DESC, "Process BTRM CTRL func")
  field (LNK1, "BTRM:LI24:720:ALLFUNCGO")
  field (LNK2, "BTRM:LI24:810:ALLFUNCGO")
  field (LNK3, "BTRM:LI24:880:ALLFUNCGO")
  field (FLNK, "MGNT:LI24:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI24:1:QUADFUNCGO") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI24:201:ALLFUNCGO")
  field (LNK2, "QUAD:LI24:301:ALLFUNCGO")
  field (LNK3, "QUAD:LI24:401:ALLFUNCGO")
  field (LNK4, "QUAD:LI24:501:ALLFUNCGO")
  field (FLNK, "MGNT:LI24:1:QUADFUNCGO2")
}

record (fanout, "MGNT:LI24:1:QUADFUNCGO2") {
  field (DESC, "Process QUAD CTRL func2")
  field (LNK1, "QUAD:LI24:601:ALLFUNCGO")
  field (LNK2, "QUAD:LI24:701:ALLFUNCGO")
  field (LNK3, "QUAD:LI24:702:ALLFUNCGO")
  field (LNK4, "QUAD:LI24:713:ALLFUNCGO")
  field (LNK5, "QUAD:LI24:740:ALLFUNCGO")
  field (LNK6, "QUAD:LI24:860:ALLFUNCGO")
  field (FLNK, "MGNT:LI24:1:QUADFUNCGO3")
}

record (fanout, "MGNT:LI24:1:QUADFUNCGO3") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI24:892:ALLFUNCGO")
  field (LNK2, "QUAD:LI24:901:ALLFUNCGO")
  field (FLNK, "MGNT:LI24:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI24:1:XCORFUNCGO") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI24:202:ALLFUNCGO")
  field (LNK2, "XCOR:LI24:302:ALLFUNCGO")
  field (LNK3, "XCOR:LI24:402:ALLFUNCGO")
  field (LNK4, "XCOR:LI24:502:ALLFUNCGO")
  field (LNK5, "XCOR:LI24:602:ALLFUNCGO")
  field (LNK6, "XCOR:LI24:702:ALLFUNCGO")
  field (FLNK, "MGNT:LI24:1:XCORFUNCGO1")
}

record (fanout, "MGNT:LI24:1:XCORFUNCGO1") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI24:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI24:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI24:1:YCORFUNCGO") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI24:203:ALLFUNCGO")
  field (LNK2, "YCOR:LI24:303:ALLFUNCGO")
  field (LNK3, "YCOR:LI24:403:ALLFUNCGO")
  field (LNK4, "YCOR:LI24:503:ALLFUNCGO")
  field (LNK5, "YCOR:LI24:603:ALLFUNCGO")
  field (LNK6, "YCOR:LI24:703:ALLFUNCGO")
  field (FLNK, "MGNT:LI24:1:YCORFUNCGO1")
}

record (fanout, "MGNT:LI24:1:YCORFUNCGO1") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI24:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI24:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI24:1:LGPSFUNCGO"){
  field (DESC, "Process LGPS CTRL func")
  field (LNK1, "LGPS:LI24:2:ALLFUNCGO")
  field (LNK2, "LGPS:LI24:3:ALLFUNCGO")
  field (FLNK, "MGNT:LI24:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI24:1:SOLNFUNCGO"){
  field (DESC, "Process SOLN CTRL func")
  field (FLNK, "MGNT:LI24:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI24:1:KICKFUNCGO"){
  field (DESC, "Process KICK CTRL func")
  field (FLNK, "MGNT:LI24:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI24:1:SEXTFUNCGO"){
  field (DESC, "Process SEXT CTRL func")
  field (FLNK, "MGNT:LI24:1:CTRLCLEAR")
}

# End of file


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record (seq, "MGNT:LI30:1:ALLBENDSSEL"){
}
record (seq, "MGNT:LI30:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:LI30:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:LI30:1:ALLKICKSSEL"){
}
record (seq, "MGNT:LI30:1:ALLSEXTSSEL"){
}

record (seq, "MGNT:LI30:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:LI30:1:ALLXCORS")
  field (DOL2, "MGNT:LI30:1:ALLXCORS")
  field (DOL3, "MGNT:LI30:1:ALLXCORS")
  field (DOL4, "MGNT:LI30:1:ALLXCORS")
  field (DOL5, "MGNT:LI30:1:ALLXCORS")
  field (DOL6, "MGNT:LI30:1:ALLXCORS")
  field (DOL7, "MGNT:LI30:1:ALLXCORS")
  field (DOL8, "MGNT:LI30:1:ALLXCORS")
  field (LNK1, "XCOR:LI30:202:SELECT CPP NMS")
  field (LNK2, "XCOR:LI30:302:SELECT CPP NMS")
  field (LNK3, "XCOR:LI30:402:SELECT CPP NMS")
  field (LNK4, "XCOR:LI30:502:SELECT CPP NMS")
  field (LNK5, "XCOR:LI30:602:SELECT CPP NMS")
  field (LNK6, "XCOR:LI30:702:SELECT CPP NMS")
  field (LNK7, "XCOR:LI30:802:SELECT CPP NMS")
  field (LNK8, "XCOR:LI30:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI30:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:LI30:1:ALLYCORS")
  field (DOL2, "MGNT:LI30:1:ALLYCORS")
  field (DOL3, "MGNT:LI30:1:ALLYCORS")
  field (DOL4, "MGNT:LI30:1:ALLYCORS")
  field (DOL5, "MGNT:LI30:1:ALLYCORS")
  field (DOL6, "MGNT:LI30:1:ALLYCORS")
  field (DOL7, "MGNT:LI30:1:ALLYCORS")
  field (DOL8, "MGNT:LI30:1:ALLYCORS")
  field (LNK1, "YCOR:LI30:203:SELECT CPP NMS")
  field (LNK2, "YCOR:LI30:303:SELECT CPP NMS")
  field (LNK3, "YCOR:LI30:403:SELECT CPP NMS")
  field (LNK4, "YCOR:LI30:503:SELECT CPP NMS")
  field (LNK5, "YCOR:LI30:603:SELECT CPP NMS")
  field (LNK6, "YCOR:LI30:703:SELECT CPP NMS")
  field (LNK7, "YCOR:LI30:803:SELECT CPP NMS")
  field (LNK8, "YCOR:LI30:900:SELECT CPP NMS")
}

record (seq, "MGNT:LI30:1:ALLLGPSSSEL"){
  field (DOL1, "MGNT:LI30:1:ALLLGPSS")
  field (LNK1, "LGPS:LI30:2:SELECT CPP NMS")
}

record (seq, "MGNT:LI30:1:ALLQUADSSEL"){
  field (DOL1, "MGNT:LI30:1:ALLQUADS")
  field (DOL2, "MGNT:LI30:1:ALLQUADS")
  field (DOL3, "MGNT:LI30:1:ALLQUADS")
  field (DOL4, "MGNT:LI30:1:ALLQUADS")
  field (DOL5, "MGNT:LI30:1:ALLQUADS")
  field (DOL6, "MGNT:LI30:1:ALLQUADS")
  field (DOL7, "MGNT:LI30:1:ALLQUADS")
  field (LNK1, "QUAD:LI30:201:SELECT CPP NMS")
  field (LNK2, "QUAD:LI30:301:SELECT CPP NMS")
  field (LNK3, "QUAD:LI30:401:SELECT CPP NMS")
  field (LNK4, "QUAD:LI30:501:SELECT CPP NMS")
  field (LNK5, "QUAD:LI30:601:SELECT CPP NMS")
  field (LNK6, "QUAD:LI30:701:SELECT CPP NMS")
  field (LNK7, "QUAD:LI30:801:SELECT CPP NMS")
}

record (seq, "MGNT:LI30:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:LI30:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:LI30:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:LI30:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:LI30:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:LI30:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:LI30:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:LI30:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:LI30:1:ALLFUNCGO1")
}
record(seq, "MGNT:LI30:1:ALLFUNCGO1") {
  field(DESC, "Process CTRL func")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:LI30:1:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:LI30:1:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:LI30:1:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:LI30:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:LI30:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI30:1:QUADFUNCGO") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI30:201:ALLFUNCGO")
  field (LNK2, "QUAD:LI30:301:ALLFUNCGO")
  field (LNK3, "QUAD:LI30:401:ALLFUNCGO")
  field (LNK4, "QUAD:LI30:501:ALLFUNCGO")
  field (LNK5, "QUAD:LI30:601:ALLFUNCGO")
  field (LNK6, "QUAD:LI30:701:ALLFUNCGO")
  field (FLNK, "MGNT:LI30:1:QUADFUNCGO1")
}

record (fanout, "MGNT:LI30:1:QUADFUNCGO1") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:LI30:801:ALLFUNCGO")
  field (FLNK, "MGNT:LI30:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI30:1:XCORFUNCGO") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI30:202:ALLFUNCGO")
  field (LNK2, "XCOR:LI30:302:ALLFUNCGO")
  field (LNK3, "XCOR:LI30:402:ALLFUNCGO")
  field (LNK4, "XCOR:LI30:502:ALLFUNCGO")
  field (LNK5, "XCOR:LI30:602:ALLFUNCGO")
  field (LNK6, "XCOR:LI30:702:ALLFUNCGO")
  field (FLNK, "MGNT:LI30:1:XCORFUNCGO1")
}

record (fanout, "MGNT:LI30:1:XCORFUNCGO1") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:LI30:802:ALLFUNCGO")
  field (LNK2, "XCOR:LI30:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI30:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI30:1:YCORFUNCGO") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI30:203:ALLFUNCGO")
  field (LNK2, "YCOR:LI30:303:ALLFUNCGO")
  field (LNK3, "YCOR:LI30:403:ALLFUNCGO")
  field (LNK4, "YCOR:LI30:503:ALLFUNCGO")
  field (LNK5, "YCOR:LI30:603:ALLFUNCGO")
  field (LNK6, "YCOR:LI30:703:ALLFUNCGO")
  field (FLNK, "MGNT:LI30:1:YCORFUNCGO1")
}

record (fanout, "MGNT:LI30:1:YCORFUNCGO1") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:LI30:803:ALLFUNCGO")
  field (LNK2, "YCOR:LI30:900:ALLFUNCGO")
  field (FLNK, "MGNT:LI30:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI30:1:LGPSFUNCGO"){
  field (DESC, "Process LGPS CTRL func")
  field (LNK1, "LGPS:LI30:2:ALLFUNCGO")
  field (FLNK, "MGNT:LI30:1:CTRLCLEAR")
}

record (fanout, "MGNT:LI30:1:BENDFUNCGO"){
  field (DESC, "Process BEND CTRL func")
  field (FLNK, "MGNT:LI30:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI30:1:BTRMFUNCGO"){
  field (DESC, "Process BTRM CTRL func")
  field (FLNK, "MGNT:LI30:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI30:1:SOLNFUNCGO"){
  field (DESC, "Process SOLN CTRL func")
  field (FLNK, "MGNT:LI30:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI30:1:KICKFUNCGO"){
  field (DESC, "Process KICK CTRL func")
  field (FLNK, "MGNT:LI30:1:CTRLCLEAR")
}
record (fanout, "MGNT:LI30:1:SEXTFUNCGO"){
  field (DESC, "Process SEXT CTRL func")
  field (FLNK, "MGNT:LI30:1:CTRLCLEAR")
}

# End of file


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LI21:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "LGPS:LI21:2:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LI21:2:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LI21:2:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LI21:2:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LI21:2:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LI21:2:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LI21:2:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LI21:2:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LI21:2:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LI21:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LI21:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LI21:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LI21:2:EDES.PROC PP")
    field(LNK2, "LGPS:LI21:2:EACT.PROC PP")
    field(LNK3, "LGPS:LI21:2:EERR.DISA PP")
    field(LNK4, "LGPS:LI21:2:ECON.PROC PP")
    field(LNK5, "LGPS:LI21:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:LI21:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:LI21:2:BLEM.PROC PP")
    field(LNK8, "LGPS:LI21:2:BMOD.PROC PP")
    field(LNK9, "LGPS:LI21:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LI21:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LI21:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LI21:2:BMAX")
  field(DOL2, "LGPS:LI21:2:BMAX")
  field(DOL3, "LGPS:LI21:2:BMAX")
  field(DOL4, "LGPS:LI21:2:BMIN")
  field(DOL5, "LGPS:LI21:2:BMIN")
  field(DOL6, "LGPS:LI21:2:BMIN")
  field(LNK1, "LGPS:LI21:2:BMAGX.HOPR")
  field(LNK2, "LGPS:LI21:2:BMAGY.HOPR")
  field(LNK3, "LGPS:LI21:2:BLEM.HOPR")
  field(LNK4, "LGPS:LI21:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LI21:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LI21:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LI21:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LI21:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LI21:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LI21:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LI21:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI21:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI21:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI21:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI21:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI21:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LI21:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LI21:2:EDES NPP MS")
  field(INPB, "LGPS:LI21:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LI21:3:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "LGPS:LI21:3:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LI21:3:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LI21:3:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LI21:3:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LI21:3:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LI21:3:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LI21:3:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LI21:3:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LI21:3:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LI21:3:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LI21:3:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LI21:3:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LI21:3:EDES.PROC PP")
    field(LNK2, "LGPS:LI21:3:EACT.PROC PP")
    field(LNK3, "LGPS:LI21:3:EERR.DISA PP")
    field(LNK4, "LGPS:LI21:3:ECON.PROC PP")
    field(LNK5, "LGPS:LI21:3:BMAGX.PROC PP")
    field(LNK6, "LGPS:LI21:3:BMAGY.PROC PP")
    field(LNK7, "LGPS:LI21:3:BLEM.PROC PP")
    field(LNK8, "LGPS:LI21:3:BMOD.PROC PP")
    field(LNK9, "LGPS:LI21:3:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LI21:3:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LI21:3:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LI21:3:BMAX")
  field(DOL2, "LGPS:LI21:3:BMAX")
  field(DOL3, "LGPS:LI21:3:BMAX")
  field(DOL4, "LGPS:LI21:3:BMIN")
  field(DOL5, "LGPS:LI21:3:BMIN")
  field(DOL6, "LGPS:LI21:3:BMIN")
  field(LNK1, "LGPS:LI21:3:BMAGX.HOPR")
  field(LNK2, "LGPS:LI21:3:BMAGY.HOPR")
  field(LNK3, "LGPS:LI21:3:BLEM.HOPR")
  field(LNK4, "LGPS:LI21:3:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LI21:3:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LI21:3:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LI21:3:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LI21:3:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LI21:3:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LI21:3:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LI21:3:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI21:3:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI21:3:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI21:3:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI21:3:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI21:3:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LI21:3:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LI21:3:EDES NPP MS")
  field(INPB, "LGPS:LI21:3:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:LI21:929:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "KICK:LI21:929:1:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:LI21:929:1:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:LI21:929:1:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:LI21:929:1:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:LI21:929:1:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:LI21:929:1:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:LI21:929:1:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:LI21:929:1:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:LI21:929:1:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:LI21:929:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:LI21:929:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:LI21:929:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:LI21:929:1:EDES.PROC PP")
    field(LNK2, "KICK:LI21:929:1:EACT.PROC PP")
    field(LNK3, "KICK:LI21:929:1:EERR.DISA PP")
    field(LNK4, "KICK:LI21:929:1:ECON.PROC PP")
    field(LNK5, "KICK:LI21:929:1:BMAGX.PROC PP")
    field(LNK6, "KICK:LI21:929:1:BMAGY.PROC PP")
    field(LNK7, "KICK:LI21:929:1:BLEM.PROC PP")
    field(LNK8, "KICK:LI21:929:1:BMOD.PROC PP")
    field(LNK9, "KICK:LI21:929:1:EDESSAVE.PROC PP")
    field(LNKA, "KICK:LI21:929:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:LI21:929:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:LI21:929:1:BMAX")
  field(DOL2, "KICK:LI21:929:1:BMAX")
  field(DOL3, "KICK:LI21:929:1:BMAX")
  field(DOL4, "KICK:LI21:929:1:BMIN")
  field(DOL5, "KICK:LI21:929:1:BMIN")
  field(DOL6, "KICK:LI21:929:1:BMIN")
  field(LNK1, "KICK:LI21:929:1:BMAGX.HOPR")
  field(LNK2, "KICK:LI21:929:1:BMAGY.HOPR")
  field(LNK3, "KICK:LI21:929:1:BLEM.HOPR")
  field(LNK4, "KICK:LI21:929:1:BMAGX.LOPR PP")
  field(LNK5, "KICK:LI21:929:1:BMAGY.LOPR PP")
  field(LNK6, "KICK:LI21:929:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:LI21:929:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:LI21:929:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:LI21:929:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:LI21:929:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:LI21:929:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI21:929:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI21:929:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI21:929:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI21:929:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI21:929:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:LI21:929:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:LI21:929:1:EDES NPP MS")
  field(INPB, "KICK:LI21:929:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:LI21:929:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "KICK:LI21:929:2:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:LI21:929:2:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:LI21:929:2:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:LI21:929:2:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:LI21:929:2:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:LI21:929:2:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:LI21:929:2:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:LI21:929:2:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:LI21:929:2:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:LI21:929:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:LI21:929:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:LI21:929:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:LI21:929:2:EDES.PROC PP")
    field(LNK2, "KICK:LI21:929:2:EACT.PROC PP")
    field(LNK3, "KICK:LI21:929:2:EERR.DISA PP")
    field(LNK4, "KICK:LI21:929:2:ECON.PROC PP")
    field(LNK5, "KICK:LI21:929:2:BMAGX.PROC PP")
    field(LNK6, "KICK:LI21:929:2:BMAGY.PROC PP")
    field(LNK7, "KICK:LI21:929:2:BLEM.PROC PP")
    field(LNK8, "KICK:LI21:929:2:BMOD.PROC PP")
    field(LNK9, "KICK:LI21:929:2:EDESSAVE.PROC PP")
    field(LNKA, "KICK:LI21:929:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:LI21:929:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:LI21:929:2:BMAX")
  field(DOL2, "KICK:LI21:929:2:BMAX")
  field(DOL3, "KICK:LI21:929:2:BMAX")
  field(DOL4, "KICK:LI21:929:2:BMIN")
  field(DOL5, "KICK:LI21:929:2:BMIN")
  field(DOL6, "KICK:LI21:929:2:BMIN")
  field(LNK1, "KICK:LI21:929:2:BMAGX.HOPR")
  field(LNK2, "KICK:LI21:929:2:BMAGY.HOPR")
  field(LNK3, "KICK:LI21:929:2:BLEM.HOPR")
  field(LNK4, "KICK:LI21:929:2:BMAGX.LOPR PP")
  field(LNK5, "KICK:LI21:929:2:BMAGY.LOPR PP")
  field(LNK6, "KICK:LI21:929:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:LI21:929:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:LI21:929:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:LI21:929:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:LI21:929:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:LI21:929:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI21:929:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI21:929:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI21:929:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI21:929:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI21:929:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:LI21:929:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:LI21:929:2:EDES NPP MS")
  field(INPB, "KICK:LI21:929:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:LI21:957:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "KICK:LI21:957:1:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:LI21:957:1:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:LI21:957:1:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:LI21:957:1:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:LI21:957:1:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:LI21:957:1:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:LI21:957:1:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:LI21:957:1:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:LI21:957:1:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:LI21:957:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:LI21:957:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:LI21:957:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:LI21:957:1:EDES.PROC PP")
    field(LNK2, "KICK:LI21:957:1:EACT.PROC PP")
    field(LNK3, "KICK:LI21:957:1:EERR.DISA PP")
    field(LNK4, "KICK:LI21:957:1:ECON.PROC PP")
    field(LNK5, "KICK:LI21:957:1:BMAGX.PROC PP")
    field(LNK6, "KICK:LI21:957:1:BMAGY.PROC PP")
    field(LNK7, "KICK:LI21:957:1:BLEM.PROC PP")
    field(LNK8, "KICK:LI21:957:1:BMOD.PROC PP")
    field(LNK9, "KICK:LI21:957:1:EDESSAVE.PROC PP")
    field(LNKA, "KICK:LI21:957:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:LI21:957:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:LI21:957:1:BMAX")
  field(DOL2, "KICK:LI21:957:1:BMAX")
  field(DOL3, "KICK:LI21:957:1:BMAX")
  field(DOL4, "KICK:LI21:957:1:BMIN")
  field(DOL5, "KICK:LI21:957:1:BMIN")
  field(DOL6, "KICK:LI21:957:1:BMIN")
  field(LNK1, "KICK:LI21:957:1:BMAGX.HOPR")
  field(LNK2, "KICK:LI21:957:1:BMAGY.HOPR")
  field(LNK3, "KICK:LI21:957:1:BLEM.HOPR")
  field(LNK4, "KICK:LI21:957:1:BMAGX.LOPR PP")
  field(LNK5, "KICK:LI21:957:1:BMAGY.LOPR PP")
  field(LNK6, "KICK:LI21:957:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:LI21:957:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:LI21:957:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:LI21:957:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:LI21:957:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:LI21:957:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI21:957:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI21:957:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI21:957:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI21:957:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI21:957:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:LI21:957:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:LI21:957:1:EDES NPP MS")
  field(INPB, "KICK:LI21:957:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:LI21:957:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "KICK:LI21:957:2:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:LI21:957:2:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:LI21:957:2:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:LI21:957:2:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:LI21:957:2:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:LI21:957:2:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:LI21:957:2:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:LI21:957:2:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:LI21:957:2:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:LI21:957:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:LI21:957:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:LI21:957:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:LI21:957:2:EDES.PROC PP")
    field(LNK2, "KICK:LI21:957:2:EACT.PROC PP")
    field(LNK3, "KICK:LI21:957:2:EERR.DISA PP")
    field(LNK4, "KICK:LI21:957:2:ECON.PROC PP")
    field(LNK5, "KICK:LI21:957:2:BMAGX.PROC PP")
    field(LNK6, "KICK:LI21:957:2:BMAGY.PROC PP")
    field(LNK7, "KICK:LI21:957:2:BLEM.PROC PP")
    field(LNK8, "KICK:LI21:957:2:BMOD.PROC PP")
    field(LNK9, "KICK:LI21:957:2:EDESSAVE.PROC PP")
    field(LNKA, "KICK:LI21:957:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:LI21:957:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:LI21:957:2:BMAX")
  field(DOL2, "KICK:LI21:957:2:BMAX")
  field(DOL3, "KICK:LI21:957:2:BMAX")
  field(DOL4, "KICK:LI21:957:2:BMIN")
  field(DOL5, "KICK:LI21:957:2:BMIN")
  field(DOL6, "KICK:LI21:957:2:BMIN")
  field(LNK1, "KICK:LI21:957:2:BMAGX.HOPR")
  field(LNK2, "KICK:LI21:957:2:BMAGY.HOPR")
  field(LNK3, "KICK:LI21:957:2:BLEM.HOPR")
  field(LNK4, "KICK:LI21:957:2:BMAGX.LOPR PP")
  field(LNK5, "KICK:LI21:957:2:BMAGY.LOPR PP")
  field(LNK6, "KICK:LI21:957:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:LI21:957:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:LI21:957:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:LI21:957:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:LI21:957:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:LI21:957:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI21:957:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI21:957:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI21:957:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI21:957:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI21:957:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:LI21:957:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:LI21:957:2:EDES NPP MS")
  field(INPB, "KICK:LI21:957:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LI21:231:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "BEND:LI21:231:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LI21:231:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LI21:231:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LI21:231:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LI21:231:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LI21:231:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LI21:231:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LI21:231:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LI21:231:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LI21:231:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LI21:231:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LI21:231:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LI21:231:EDES.PROC PP")
    field(LNK2, "BEND:LI21:231:EACT.PROC PP")
    field(LNK3, "BEND:LI21:231:EERR.DISA PP")
    field(LNK4, "BEND:LI21:231:ECON.PROC PP")
    field(LNK5, "BEND:LI21:231:BMAGX.PROC PP")
    field(LNK6, "BEND:LI21:231:BMAGY.PROC PP")
    field(LNK7, "BEND:LI21:231:BLEM.PROC PP")
    field(LNK8, "BEND:LI21:231:BMOD.PROC PP")
    field(LNK9, "BEND:LI21:231:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LI21:231:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LI21:231:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LI21:231:BMAX")
  field(DOL2, "BEND:LI21:231:BMAX")
  field(DOL3, "BEND:LI21:231:BMAX")
  field(DOL4, "BEND:LI21:231:BMIN")
  field(DOL5, "BEND:LI21:231:BMIN")
  field(DOL6, "BEND:LI21:231:BMIN")
  field(LNK1, "BEND:LI21:231:BMAGX.HOPR")
  field(LNK2, "BEND:LI21:231:BMAGY.HOPR")
  field(LNK3, "BEND:LI21:231:BLEM.HOPR")
  field(LNK4, "BEND:LI21:231:BMAGX.LOPR PP")
  field(LNK5, "BEND:LI21:231:BMAGY.LOPR PP")
  field(LNK6, "BEND:LI21:231:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LI21:231:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LI21:231:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LI21:231:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LI21:231:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LI21:231:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI21:231:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI21:231:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LI21:231:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI21:231:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LI21:231:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LI21:231:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LI21:231:EDES NPP MS")
  field(INPB, "BEND:LI21:231:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LI21:215:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "BTRM:LI21:215:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LI21:215:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LI21:215:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LI21:215:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LI21:215:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LI21:215:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LI21:215:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LI21:215:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LI21:215:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LI21:215:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LI21:215:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LI21:215:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LI21:215:EDES.PROC PP")
    field(LNK2, "BTRM:LI21:215:EACT.PROC PP")
    field(LNK3, "BTRM:LI21:215:EERR.DISA PP")
    field(LNK4, "BTRM:LI21:215:ECON.PROC PP")
    field(LNK5, "BTRM:LI21:215:BMAGX.PROC PP")
    field(LNK6, "BTRM:LI21:215:BMAGY.PROC PP")
    field(LNK7, "BTRM:LI21:215:BLEM.PROC PP")
    field(LNK8, "BTRM:LI21:215:BMOD.PROC PP")
    field(LNK9, "BTRM:LI21:215:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LI21:215:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LI21:215:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LI21:215:BMAX")
  field(DOL2, "BTRM:LI21:215:BMAX")
  field(DOL3, "BTRM:LI21:215:BMAX")
  field(DOL4, "BTRM:LI21:215:BMIN")
  field(DOL5, "BTRM:LI21:215:BMIN")
  field(DOL6, "BTRM:LI21:215:BMIN")
  field(LNK1, "BTRM:LI21:215:BMAGX.HOPR")
  field(LNK2, "BTRM:LI21:215:BMAGY.HOPR")
  field(LNK3, "BTRM:LI21:215:BLEM.HOPR")
  field(LNK4, "BTRM:LI21:215:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LI21:215:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LI21:215:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LI21:215:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LI21:215:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LI21:215:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LI21:215:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LI21:215:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI21:215:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI21:215:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LI21:215:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI21:215:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LI21:215:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LI21:215:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LI21:215:EDES NPP MS")
  field(INPB, "BTRM:LI21:215:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LI21:241:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "BTRM:LI21:241:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LI21:241:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LI21:241:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LI21:241:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LI21:241:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LI21:241:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LI21:241:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LI21:241:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LI21:241:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LI21:241:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LI21:241:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LI21:241:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LI21:241:EDES.PROC PP")
    field(LNK2, "BTRM:LI21:241:EACT.PROC PP")
    field(LNK3, "BTRM:LI21:241:EERR.DISA PP")
    field(LNK4, "BTRM:LI21:241:ECON.PROC PP")
    field(LNK5, "BTRM:LI21:241:BMAGX.PROC PP")
    field(LNK6, "BTRM:LI21:241:BMAGY.PROC PP")
    field(LNK7, "BTRM:LI21:241:BLEM.PROC PP")
    field(LNK8, "BTRM:LI21:241:BMOD.PROC PP")
    field(LNK9, "BTRM:LI21:241:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LI21:241:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LI21:241:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LI21:241:BMAX")
  field(DOL2, "BTRM:LI21:241:BMAX")
  field(DOL3, "BTRM:LI21:241:BMAX")
  field(DOL4, "BTRM:LI21:241:BMIN")
  field(DOL5, "BTRM:LI21:241:BMIN")
  field(DOL6, "BTRM:LI21:241:BMIN")
  field(LNK1, "BTRM:LI21:241:BMAGX.HOPR")
  field(LNK2, "BTRM:LI21:241:BMAGY.HOPR")
  field(LNK3, "BTRM:LI21:241:BLEM.HOPR")
  field(LNK4, "BTRM:LI21:241:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LI21:241:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LI21:241:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LI21:241:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LI21:241:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LI21:241:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LI21:241:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LI21:241:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI21:241:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI21:241:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LI21:241:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI21:241:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LI21:241:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LI21:241:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LI21:241:EDES NPP MS")
  field(INPB, "BTRM:LI21:241:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LI21:261:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "BTRM:LI21:261:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LI21:261:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LI21:261:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LI21:261:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LI21:261:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LI21:261:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LI21:261:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LI21:261:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LI21:261:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LI21:261:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LI21:261:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LI21:261:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LI21:261:EDES.PROC PP")
    field(LNK2, "BTRM:LI21:261:EACT.PROC PP")
    field(LNK3, "BTRM:LI21:261:EERR.DISA PP")
    field(LNK4, "BTRM:LI21:261:ECON.PROC PP")
    field(LNK5, "BTRM:LI21:261:BMAGX.PROC PP")
    field(LNK6, "BTRM:LI21:261:BMAGY.PROC PP")
    field(LNK7, "BTRM:LI21:261:BLEM.PROC PP")
    field(LNK8, "BTRM:LI21:261:BMOD.PROC PP")
    field(LNK9, "BTRM:LI21:261:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LI21:261:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LI21:261:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LI21:261:BMAX")
  field(DOL2, "BTRM:LI21:261:BMAX")
  field(DOL3, "BTRM:LI21:261:BMAX")
  field(DOL4, "BTRM:LI21:261:BMIN")
  field(DOL5, "BTRM:LI21:261:BMIN")
  field(DOL6, "BTRM:LI21:261:BMIN")
  field(LNK1, "BTRM:LI21:261:BMAGX.HOPR")
  field(LNK2, "BTRM:LI21:261:BMAGY.HOPR")
  field(LNK3, "BTRM:LI21:261:BLEM.HOPR")
  field(LNK4, "BTRM:LI21:261:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LI21:261:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LI21:261:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LI21:261:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LI21:261:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LI21:261:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LI21:261:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LI21:261:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI21:261:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI21:261:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LI21:261:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI21:261:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LI21:261:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LI21:261:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LI21:261:EDES NPP MS")
  field(INPB, "BTRM:LI21:261:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:201:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:201:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:201:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:201:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:201:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:201:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:201:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:201:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:201:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:201:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:201:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:201:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:201:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:201:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:201:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:201:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:201:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:201:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:201:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:201:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:201:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:201:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:201:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:201:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:201:BMAX")
  field(DOL2, "QUAD:LI21:201:BMAX")
  field(DOL3, "QUAD:LI21:201:BMAX")
  field(DOL4, "QUAD:LI21:201:BMIN")
  field(DOL5, "QUAD:LI21:201:BMIN")
  field(DOL6, "QUAD:LI21:201:BMIN")
  field(LNK1, "QUAD:LI21:201:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:201:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:201:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:201:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:201:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:201:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:201:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:201:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:201:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:201:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:201:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:201:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:201:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:201:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:201:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:201:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:201:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:201:EDES NPP MS")
  field(INPB, "QUAD:LI21:201:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:301:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:301:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:301:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:301:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:301:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:301:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:301:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:301:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:301:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:301:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:301:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:301:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:301:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:301:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:301:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:301:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:301:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:301:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:301:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:301:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:301:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:301:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:301:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:301:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:301:BMAX")
  field(DOL2, "QUAD:LI21:301:BMAX")
  field(DOL3, "QUAD:LI21:301:BMAX")
  field(DOL4, "QUAD:LI21:301:BMIN")
  field(DOL5, "QUAD:LI21:301:BMIN")
  field(DOL6, "QUAD:LI21:301:BMIN")
  field(LNK1, "QUAD:LI21:301:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:301:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:301:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:301:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:301:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:301:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:301:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:301:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:301:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:301:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:301:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:301:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:301:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:301:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:301:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:301:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:301:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:301:EDES NPP MS")
  field(INPB, "QUAD:LI21:301:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:401:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:401:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:401:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:401:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:401:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:401:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:401:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:401:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:401:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:401:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:401:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:401:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:401:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:401:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:401:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:401:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:401:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:401:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:401:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:401:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:401:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:401:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:401:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:401:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:401:BMAX")
  field(DOL2, "QUAD:LI21:401:BMAX")
  field(DOL3, "QUAD:LI21:401:BMAX")
  field(DOL4, "QUAD:LI21:401:BMIN")
  field(DOL5, "QUAD:LI21:401:BMIN")
  field(DOL6, "QUAD:LI21:401:BMIN")
  field(LNK1, "QUAD:LI21:401:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:401:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:401:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:401:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:401:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:401:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:401:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:401:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:401:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:401:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:401:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:401:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:401:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:401:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:401:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:401:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:401:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:401:EDES NPP MS")
  field(INPB, "QUAD:LI21:401:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:501:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:501:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:501:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:501:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:501:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:501:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:501:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:501:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:501:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:501:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:501:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:501:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:501:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:501:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:501:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:501:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:501:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:501:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:501:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:501:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:501:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:501:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:501:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:501:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:501:BMAX")
  field(DOL2, "QUAD:LI21:501:BMAX")
  field(DOL3, "QUAD:LI21:501:BMAX")
  field(DOL4, "QUAD:LI21:501:BMIN")
  field(DOL5, "QUAD:LI21:501:BMIN")
  field(DOL6, "QUAD:LI21:501:BMIN")
  field(LNK1, "QUAD:LI21:501:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:501:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:501:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:501:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:501:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:501:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:501:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:501:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:501:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:501:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:501:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:501:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:501:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:501:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:501:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:501:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:501:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:501:EDES NPP MS")
  field(INPB, "QUAD:LI21:501:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:601:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:601:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:601:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:601:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:601:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:601:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:601:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:601:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:601:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:601:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:601:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:601:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:601:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:601:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:601:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:601:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:601:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:601:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:601:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:601:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:601:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:601:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:601:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:601:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:601:BMAX")
  field(DOL2, "QUAD:LI21:601:BMAX")
  field(DOL3, "QUAD:LI21:601:BMAX")
  field(DOL4, "QUAD:LI21:601:BMIN")
  field(DOL5, "QUAD:LI21:601:BMIN")
  field(DOL6, "QUAD:LI21:601:BMIN")
  field(LNK1, "QUAD:LI21:601:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:601:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:601:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:601:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:601:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:601:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:601:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:601:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:601:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:601:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:601:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:601:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:601:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:601:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:601:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:601:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:601:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:601:EDES NPP MS")
  field(INPB, "QUAD:LI21:601:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:701:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:701:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:701:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:701:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:701:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:701:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:701:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:701:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:701:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:701:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:701:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:701:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:701:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:701:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:701:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:701:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:701:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:701:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:701:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:701:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:701:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:701:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:701:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:701:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:701:BMAX")
  field(DOL2, "QUAD:LI21:701:BMAX")
  field(DOL3, "QUAD:LI21:701:BMAX")
  field(DOL4, "QUAD:LI21:701:BMIN")
  field(DOL5, "QUAD:LI21:701:BMIN")
  field(DOL6, "QUAD:LI21:701:BMIN")
  field(LNK1, "QUAD:LI21:701:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:701:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:701:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:701:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:701:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:701:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:701:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:701:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:701:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:701:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:701:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:701:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:701:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:701:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:701:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:701:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:701:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:701:EDES NPP MS")
  field(INPB, "QUAD:LI21:701:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:801:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:801:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:801:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:801:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:801:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:801:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:801:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:801:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:801:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:801:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:801:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:801:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:801:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:801:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:801:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:801:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:801:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:801:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:801:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:801:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:801:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:801:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:801:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:801:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:801:BMAX")
  field(DOL2, "QUAD:LI21:801:BMAX")
  field(DOL3, "QUAD:LI21:801:BMAX")
  field(DOL4, "QUAD:LI21:801:BMIN")
  field(DOL5, "QUAD:LI21:801:BMIN")
  field(DOL6, "QUAD:LI21:801:BMIN")
  field(LNK1, "QUAD:LI21:801:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:801:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:801:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:801:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:801:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:801:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:801:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:801:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:801:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:801:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:801:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:801:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:801:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:801:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:801:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:801:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:801:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:801:EDES NPP MS")
  field(INPB, "QUAD:LI21:801:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:901:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:901:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:901:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:901:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:901:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:901:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:901:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:901:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:901:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:901:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:901:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:901:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:901:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:901:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:901:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:901:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:901:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:901:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:901:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:901:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:901:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:901:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:901:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:901:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:901:BMAX")
  field(DOL2, "QUAD:LI21:901:BMAX")
  field(DOL3, "QUAD:LI21:901:BMAX")
  field(DOL4, "QUAD:LI21:901:BMIN")
  field(DOL5, "QUAD:LI21:901:BMIN")
  field(DOL6, "QUAD:LI21:901:BMIN")
  field(LNK1, "QUAD:LI21:901:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:901:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:901:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:901:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:901:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:901:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:901:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:901:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:901:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:901:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:901:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:901:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:901:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:901:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:901:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:901:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:901:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:901:EDES NPP MS")
  field(INPB, "QUAD:LI21:901:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:243:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:243:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:243:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:243:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:243:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:243:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:243:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:243:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:243:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:243:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:243:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:243:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:243:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:243:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:243:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:243:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:243:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:243:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:243:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:243:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:243:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:243:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:243:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:243:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:243:BMAX")
  field(DOL2, "QUAD:LI21:243:BMAX")
  field(DOL3, "QUAD:LI21:243:BMAX")
  field(DOL4, "QUAD:LI21:243:BMIN")
  field(DOL5, "QUAD:LI21:243:BMIN")
  field(DOL6, "QUAD:LI21:243:BMIN")
  field(LNK1, "QUAD:LI21:243:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:243:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:243:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:243:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:243:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:243:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:243:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:243:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:243:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:243:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:243:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:243:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:243:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:243:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:243:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:243:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:243:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:243:EDES NPP MS")
  field(INPB, "QUAD:LI21:243:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:131:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:131:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:131:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:131:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:131:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:131:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:131:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:131:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:131:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:131:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:131:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:131:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:131:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:131:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:131:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:131:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:131:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:131:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:131:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:131:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:131:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:131:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:131:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:131:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:131:BMAX")
  field(DOL2, "QUAD:LI21:131:BMAX")
  field(DOL3, "QUAD:LI21:131:BMAX")
  field(DOL4, "QUAD:LI21:131:BMIN")
  field(DOL5, "QUAD:LI21:131:BMIN")
  field(DOL6, "QUAD:LI21:131:BMIN")
  field(LNK1, "QUAD:LI21:131:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:131:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:131:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:131:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:131:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:131:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:131:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:131:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:131:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:131:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:131:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:131:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:131:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:131:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:131:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:131:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:131:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:131:EDES NPP MS")
  field(INPB, "QUAD:LI21:131:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:161:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:161:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:161:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:161:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:161:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:161:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:161:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:161:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:161:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:161:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:161:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:161:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:161:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:161:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:161:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:161:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:161:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:161:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:161:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:161:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:161:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:161:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:161:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:161:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:161:BMAX")
  field(DOL2, "QUAD:LI21:161:BMAX")
  field(DOL3, "QUAD:LI21:161:BMAX")
  field(DOL4, "QUAD:LI21:161:BMIN")
  field(DOL5, "QUAD:LI21:161:BMIN")
  field(DOL6, "QUAD:LI21:161:BMIN")
  field(LNK1, "QUAD:LI21:161:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:161:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:161:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:161:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:161:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:161:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:161:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:161:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:161:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:161:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:161:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:161:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:161:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:161:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:161:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:161:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:161:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:161:EDES NPP MS")
  field(INPB, "QUAD:LI21:161:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:211:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:211:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:211:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:211:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:211:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:211:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:211:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:211:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:211:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:211:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:211:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:211:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:211:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:211:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:211:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:211:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:211:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:211:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:211:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:211:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:211:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:211:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:211:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:211:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:211:BMAX")
  field(DOL2, "QUAD:LI21:211:BMAX")
  field(DOL3, "QUAD:LI21:211:BMAX")
  field(DOL4, "QUAD:LI21:211:BMIN")
  field(DOL5, "QUAD:LI21:211:BMIN")
  field(DOL6, "QUAD:LI21:211:BMIN")
  field(LNK1, "QUAD:LI21:211:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:211:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:211:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:211:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:211:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:211:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:211:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:211:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:211:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:211:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:211:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:211:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:211:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:211:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:211:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:211:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:211:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:211:EDES NPP MS")
  field(INPB, "QUAD:LI21:211:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:221:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:221:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:221:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:221:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:221:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:221:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:221:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:221:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:221:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:221:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:221:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:221:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:221:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:221:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:221:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:221:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:221:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:221:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:221:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:221:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:221:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:221:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:221:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:221:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:221:BMAX")
  field(DOL2, "QUAD:LI21:221:BMAX")
  field(DOL3, "QUAD:LI21:221:BMAX")
  field(DOL4, "QUAD:LI21:221:BMIN")
  field(DOL5, "QUAD:LI21:221:BMIN")
  field(DOL6, "QUAD:LI21:221:BMIN")
  field(LNK1, "QUAD:LI21:221:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:221:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:221:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:221:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:221:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:221:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:221:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:221:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:221:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:221:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:221:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:221:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:221:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:221:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:221:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:221:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:221:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:221:EDES NPP MS")
  field(INPB, "QUAD:LI21:221:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:251:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:251:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:251:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:251:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:251:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:251:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:251:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:251:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:251:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:251:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:251:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:251:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:251:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:251:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:251:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:251:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:251:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:251:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:251:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:251:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:251:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:251:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:251:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:251:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:251:BMAX")
  field(DOL2, "QUAD:LI21:251:BMAX")
  field(DOL3, "QUAD:LI21:251:BMAX")
  field(DOL4, "QUAD:LI21:251:BMIN")
  field(DOL5, "QUAD:LI21:251:BMIN")
  field(DOL6, "QUAD:LI21:251:BMIN")
  field(LNK1, "QUAD:LI21:251:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:251:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:251:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:251:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:251:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:251:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:251:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:251:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:251:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:251:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:251:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:251:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:251:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:251:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:251:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:251:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:251:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:251:EDES NPP MS")
  field(INPB, "QUAD:LI21:251:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:271:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:271:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:271:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:271:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:271:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:271:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:271:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:271:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:271:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:271:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:271:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:271:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:271:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:271:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:271:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:271:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:271:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:271:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:271:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:271:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:271:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:271:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:271:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:271:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:271:BMAX")
  field(DOL2, "QUAD:LI21:271:BMAX")
  field(DOL3, "QUAD:LI21:271:BMAX")
  field(DOL4, "QUAD:LI21:271:BMIN")
  field(DOL5, "QUAD:LI21:271:BMIN")
  field(DOL6, "QUAD:LI21:271:BMIN")
  field(LNK1, "QUAD:LI21:271:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:271:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:271:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:271:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:271:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:271:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:271:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:271:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:271:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:271:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:271:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:271:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:271:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:271:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:271:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:271:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:271:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:271:EDES NPP MS")
  field(INPB, "QUAD:LI21:271:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:278:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:278:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:278:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:278:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:278:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:278:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:278:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:278:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:278:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:278:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:278:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:278:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:278:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:278:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:278:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:278:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:278:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:278:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:278:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:278:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:278:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:278:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:278:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:278:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:278:BMAX")
  field(DOL2, "QUAD:LI21:278:BMAX")
  field(DOL3, "QUAD:LI21:278:BMAX")
  field(DOL4, "QUAD:LI21:278:BMIN")
  field(DOL5, "QUAD:LI21:278:BMIN")
  field(DOL6, "QUAD:LI21:278:BMIN")
  field(LNK1, "QUAD:LI21:278:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:278:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:278:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:278:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:278:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:278:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:278:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:278:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:278:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:278:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:278:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:278:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:278:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:278:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:278:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:278:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:278:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:278:EDES NPP MS")
  field(INPB, "QUAD:LI21:278:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:315:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:315:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:315:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:315:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:315:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:315:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:315:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:315:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:315:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:315:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:315:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:315:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:315:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:315:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:315:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:315:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:315:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:315:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:315:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:315:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:315:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:315:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:315:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:315:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:315:BMAX")
  field(DOL2, "QUAD:LI21:315:BMAX")
  field(DOL3, "QUAD:LI21:315:BMAX")
  field(DOL4, "QUAD:LI21:315:BMIN")
  field(DOL5, "QUAD:LI21:315:BMIN")
  field(DOL6, "QUAD:LI21:315:BMIN")
  field(LNK1, "QUAD:LI21:315:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:315:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:315:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:315:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:315:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:315:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:315:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:315:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:315:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:315:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:315:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:315:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:315:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:315:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:315:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:315:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:315:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:315:EDES NPP MS")
  field(INPB, "QUAD:LI21:315:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI21:335:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI21:335:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI21:335:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI21:335:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI21:335:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI21:335:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI21:335:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI21:335:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI21:335:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI21:335:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI21:335:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI21:335:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI21:335:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI21:335:EDES.PROC PP")
    field(LNK2, "QUAD:LI21:335:EACT.PROC PP")
    field(LNK3, "QUAD:LI21:335:EERR.DISA PP")
    field(LNK4, "QUAD:LI21:335:ECON.PROC PP")
    field(LNK5, "QUAD:LI21:335:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI21:335:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI21:335:BLEM.PROC PP")
    field(LNK8, "QUAD:LI21:335:BMOD.PROC PP")
    field(LNK9, "QUAD:LI21:335:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI21:335:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI21:335:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI21:335:BMAX")
  field(DOL2, "QUAD:LI21:335:BMAX")
  field(DOL3, "QUAD:LI21:335:BMAX")
  field(DOL4, "QUAD:LI21:335:BMIN")
  field(DOL5, "QUAD:LI21:335:BMIN")
  field(DOL6, "QUAD:LI21:335:BMIN")
  field(LNK1, "QUAD:LI21:335:BMAGX.HOPR")
  field(LNK2, "QUAD:LI21:335:BMAGY.HOPR")
  field(LNK3, "QUAD:LI21:335:BLEM.HOPR")
  field(LNK4, "QUAD:LI21:335:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI21:335:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI21:335:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:335:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI21:335:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI21:335:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI21:335:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI21:335:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:335:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:335:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:335:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI21:335:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI21:335:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI21:335:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI21:335:EDES NPP MS")
  field(INPB, "QUAD:LI21:335:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI21:175:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI21:175:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI21:175:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI21:175:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI21:175:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI21:175:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI21:175:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI21:175:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI21:175:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI21:175:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI21:175:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI21:175:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI21:175:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI21:175:EDES.PROC PP")
    field(LNK2, "XCOR:LI21:175:EACT.PROC PP")
    field(LNK3, "XCOR:LI21:175:EERR.DISA PP")
    field(LNK4, "XCOR:LI21:175:ECON.PROC PP")
    field(LNK5, "XCOR:LI21:175:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI21:175:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI21:175:BLEM.PROC PP")
    field(LNK8, "XCOR:LI21:175:BMOD.PROC PP")
    field(LNK9, "XCOR:LI21:175:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI21:175:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI21:175:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI21:175:BMAX")
  field(DOL2, "XCOR:LI21:175:BMAX")
  field(DOL3, "XCOR:LI21:175:BMAX")
  field(DOL4, "XCOR:LI21:175:BMIN")
  field(DOL5, "XCOR:LI21:175:BMIN")
  field(DOL6, "XCOR:LI21:175:BMIN")
  field(LNK1, "XCOR:LI21:175:BMAGX.HOPR")
  field(LNK2, "XCOR:LI21:175:BMAGY.HOPR")
  field(LNK3, "XCOR:LI21:175:BLEM.HOPR")
  field(LNK4, "XCOR:LI21:175:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI21:175:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI21:175:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:175:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:175:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI21:175:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI21:175:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI21:175:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:175:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:175:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:175:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:175:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:175:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI21:175:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI21:175:EDES NPP MS")
  field(INPB, "XCOR:LI21:175:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI21:402:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI21:402:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI21:402:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI21:402:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI21:402:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI21:402:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI21:402:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI21:402:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI21:402:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI21:402:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI21:402:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI21:402:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI21:402:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI21:402:EDES.PROC PP")
    field(LNK2, "XCOR:LI21:402:EACT.PROC PP")
    field(LNK3, "XCOR:LI21:402:EERR.DISA PP")
    field(LNK4, "XCOR:LI21:402:ECON.PROC PP")
    field(LNK5, "XCOR:LI21:402:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI21:402:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI21:402:BLEM.PROC PP")
    field(LNK8, "XCOR:LI21:402:BMOD.PROC PP")
    field(LNK9, "XCOR:LI21:402:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI21:402:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI21:402:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI21:402:BMAX")
  field(DOL2, "XCOR:LI21:402:BMAX")
  field(DOL3, "XCOR:LI21:402:BMAX")
  field(DOL4, "XCOR:LI21:402:BMIN")
  field(DOL5, "XCOR:LI21:402:BMIN")
  field(DOL6, "XCOR:LI21:402:BMIN")
  field(LNK1, "XCOR:LI21:402:BMAGX.HOPR")
  field(LNK2, "XCOR:LI21:402:BMAGY.HOPR")
  field(LNK3, "XCOR:LI21:402:BLEM.HOPR")
  field(LNK4, "XCOR:LI21:402:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI21:402:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI21:402:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:402:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:402:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI21:402:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI21:402:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI21:402:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:402:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:402:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:402:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:402:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:402:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI21:402:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI21:402:EDES NPP MS")
  field(INPB, "XCOR:LI21:402:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI21:502:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI21:502:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI21:502:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI21:502:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI21:502:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI21:502:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI21:502:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI21:502:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI21:502:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI21:502:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI21:502:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI21:502:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI21:502:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI21:502:EDES.PROC PP")
    field(LNK2, "XCOR:LI21:502:EACT.PROC PP")
    field(LNK3, "XCOR:LI21:502:EERR.DISA PP")
    field(LNK4, "XCOR:LI21:502:ECON.PROC PP")
    field(LNK5, "XCOR:LI21:502:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI21:502:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI21:502:BLEM.PROC PP")
    field(LNK8, "XCOR:LI21:502:BMOD.PROC PP")
    field(LNK9, "XCOR:LI21:502:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI21:502:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI21:502:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI21:502:BMAX")
  field(DOL2, "XCOR:LI21:502:BMAX")
  field(DOL3, "XCOR:LI21:502:BMAX")
  field(DOL4, "XCOR:LI21:502:BMIN")
  field(DOL5, "XCOR:LI21:502:BMIN")
  field(DOL6, "XCOR:LI21:502:BMIN")
  field(LNK1, "XCOR:LI21:502:BMAGX.HOPR")
  field(LNK2, "XCOR:LI21:502:BMAGY.HOPR")
  field(LNK3, "XCOR:LI21:502:BLEM.HOPR")
  field(LNK4, "XCOR:LI21:502:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI21:502:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI21:502:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:502:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:502:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI21:502:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI21:502:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI21:502:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:502:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:502:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:502:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:502:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:502:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI21:502:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI21:502:EDES NPP MS")
  field(INPB, "XCOR:LI21:502:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI21:602:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI21:602:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI21:602:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI21:602:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI21:602:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI21:602:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI21:602:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI21:602:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI21:602:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI21:602:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI21:602:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI21:602:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI21:602:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI21:602:EDES.PROC PP")
    field(LNK2, "XCOR:LI21:602:EACT.PROC PP")
    field(LNK3, "XCOR:LI21:602:EERR.DISA PP")
    field(LNK4, "XCOR:LI21:602:ECON.PROC PP")
    field(LNK5, "XCOR:LI21:602:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI21:602:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI21:602:BLEM.PROC PP")
    field(LNK8, "XCOR:LI21:602:BMOD.PROC PP")
    field(LNK9, "XCOR:LI21:602:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI21:602:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI21:602:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI21:602:BMAX")
  field(DOL2, "XCOR:LI21:602:BMAX")
  field(DOL3, "XCOR:LI21:602:BMAX")
  field(DOL4, "XCOR:LI21:602:BMIN")
  field(DOL5, "XCOR:LI21:602:BMIN")
  field(DOL6, "XCOR:LI21:602:BMIN")
  field(LNK1, "XCOR:LI21:602:BMAGX.HOPR")
  field(LNK2, "XCOR:LI21:602:BMAGY.HOPR")
  field(LNK3, "XCOR:LI21:602:BLEM.HOPR")
  field(LNK4, "XCOR:LI21:602:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI21:602:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI21:602:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:602:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:602:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI21:602:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI21:602:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI21:602:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:602:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:602:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:602:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:602:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:602:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI21:602:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI21:602:EDES NPP MS")
  field(INPB, "XCOR:LI21:602:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI21:702:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI21:702:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI21:702:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI21:702:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI21:702:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI21:702:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI21:702:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI21:702:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI21:702:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI21:702:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI21:702:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI21:702:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI21:702:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI21:702:EDES.PROC PP")
    field(LNK2, "XCOR:LI21:702:EACT.PROC PP")
    field(LNK3, "XCOR:LI21:702:EERR.DISA PP")
    field(LNK4, "XCOR:LI21:702:ECON.PROC PP")
    field(LNK5, "XCOR:LI21:702:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI21:702:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI21:702:BLEM.PROC PP")
    field(LNK8, "XCOR:LI21:702:BMOD.PROC PP")
    field(LNK9, "XCOR:LI21:702:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI21:702:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI21:702:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI21:702:BMAX")
  field(DOL2, "XCOR:LI21:702:BMAX")
  field(DOL3, "XCOR:LI21:702:BMAX")
  field(DOL4, "XCOR:LI21:702:BMIN")
  field(DOL5, "XCOR:LI21:702:BMIN")
  field(DOL6, "XCOR:LI21:702:BMIN")
  field(LNK1, "XCOR:LI21:702:BMAGX.HOPR")
  field(LNK2, "XCOR:LI21:702:BMAGY.HOPR")
  field(LNK3, "XCOR:LI21:702:BLEM.HOPR")
  field(LNK4, "XCOR:LI21:702:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI21:702:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI21:702:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:702:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:702:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI21:702:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI21:702:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI21:702:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:702:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:702:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:702:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:702:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:702:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI21:702:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI21:702:EDES NPP MS")
  field(INPB, "XCOR:LI21:702:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI21:802:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI21:802:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI21:802:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI21:802:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI21:802:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI21:802:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI21:802:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI21:802:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI21:802:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI21:802:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI21:802:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI21:802:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI21:802:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI21:802:EDES.PROC PP")
    field(LNK2, "XCOR:LI21:802:EACT.PROC PP")
    field(LNK3, "XCOR:LI21:802:EERR.DISA PP")
    field(LNK4, "XCOR:LI21:802:ECON.PROC PP")
    field(LNK5, "XCOR:LI21:802:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI21:802:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI21:802:BLEM.PROC PP")
    field(LNK8, "XCOR:LI21:802:BMOD.PROC PP")
    field(LNK9, "XCOR:LI21:802:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI21:802:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI21:802:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI21:802:BMAX")
  field(DOL2, "XCOR:LI21:802:BMAX")
  field(DOL3, "XCOR:LI21:802:BMAX")
  field(DOL4, "XCOR:LI21:802:BMIN")
  field(DOL5, "XCOR:LI21:802:BMIN")
  field(DOL6, "XCOR:LI21:802:BMIN")
  field(LNK1, "XCOR:LI21:802:BMAGX.HOPR")
  field(LNK2, "XCOR:LI21:802:BMAGY.HOPR")
  field(LNK3, "XCOR:LI21:802:BLEM.HOPR")
  field(LNK4, "XCOR:LI21:802:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI21:802:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI21:802:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:802:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:802:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI21:802:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI21:802:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI21:802:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:802:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:802:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:802:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:802:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:802:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI21:802:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI21:802:EDES NPP MS")
  field(INPB, "XCOR:LI21:802:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI21:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI21:900:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI21:900:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI21:900:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI21:900:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI21:900:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI21:900:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI21:900:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI21:900:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI21:900:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI21:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI21:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI21:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI21:900:EDES.PROC PP")
    field(LNK2, "XCOR:LI21:900:EACT.PROC PP")
    field(LNK3, "XCOR:LI21:900:EERR.DISA PP")
    field(LNK4, "XCOR:LI21:900:ECON.PROC PP")
    field(LNK5, "XCOR:LI21:900:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI21:900:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI21:900:BLEM.PROC PP")
    field(LNK8, "XCOR:LI21:900:BMOD.PROC PP")
    field(LNK9, "XCOR:LI21:900:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI21:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI21:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI21:900:BMAX")
  field(DOL2, "XCOR:LI21:900:BMAX")
  field(DOL3, "XCOR:LI21:900:BMAX")
  field(DOL4, "XCOR:LI21:900:BMIN")
  field(DOL5, "XCOR:LI21:900:BMIN")
  field(DOL6, "XCOR:LI21:900:BMIN")
  field(LNK1, "XCOR:LI21:900:BMAGX.HOPR")
  field(LNK2, "XCOR:LI21:900:BMAGY.HOPR")
  field(LNK3, "XCOR:LI21:900:BLEM.HOPR")
  field(LNK4, "XCOR:LI21:900:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI21:900:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI21:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI21:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI21:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI21:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI21:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI21:900:EDES NPP MS")
  field(INPB, "XCOR:LI21:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI21:101:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI21:101:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI21:101:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI21:101:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI21:101:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI21:101:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI21:101:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI21:101:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI21:101:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI21:101:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI21:101:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI21:101:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI21:101:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI21:101:EDES.PROC PP")
    field(LNK2, "XCOR:LI21:101:EACT.PROC PP")
    field(LNK3, "XCOR:LI21:101:EERR.DISA PP")
    field(LNK4, "XCOR:LI21:101:ECON.PROC PP")
    field(LNK5, "XCOR:LI21:101:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI21:101:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI21:101:BLEM.PROC PP")
    field(LNK8, "XCOR:LI21:101:BMOD.PROC PP")
    field(LNK9, "XCOR:LI21:101:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI21:101:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI21:101:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI21:101:BMAX")
  field(DOL2, "XCOR:LI21:101:BMAX")
  field(DOL3, "XCOR:LI21:101:BMAX")
  field(DOL4, "XCOR:LI21:101:BMIN")
  field(DOL5, "XCOR:LI21:101:BMIN")
  field(DOL6, "XCOR:LI21:101:BMIN")
  field(LNK1, "XCOR:LI21:101:BMAGX.HOPR")
  field(LNK2, "XCOR:LI21:101:BMAGY.HOPR")
  field(LNK3, "XCOR:LI21:101:BLEM.HOPR")
  field(LNK4, "XCOR:LI21:101:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI21:101:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI21:101:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:101:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:101:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI21:101:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI21:101:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI21:101:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:101:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:101:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:101:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:101:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:101:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI21:101:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI21:101:EDES NPP MS")
  field(INPB, "XCOR:LI21:101:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI21:135:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI21:135:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI21:135:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI21:135:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI21:135:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI21:135:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI21:135:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI21:135:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI21:135:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI21:135:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI21:135:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI21:135:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI21:135:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI21:135:EDES.PROC PP")
    field(LNK2, "XCOR:LI21:135:EACT.PROC PP")
    field(LNK3, "XCOR:LI21:135:EERR.DISA PP")
    field(LNK4, "XCOR:LI21:135:ECON.PROC PP")
    field(LNK5, "XCOR:LI21:135:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI21:135:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI21:135:BLEM.PROC PP")
    field(LNK8, "XCOR:LI21:135:BMOD.PROC PP")
    field(LNK9, "XCOR:LI21:135:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI21:135:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI21:135:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI21:135:BMAX")
  field(DOL2, "XCOR:LI21:135:BMAX")
  field(DOL3, "XCOR:LI21:135:BMAX")
  field(DOL4, "XCOR:LI21:135:BMIN")
  field(DOL5, "XCOR:LI21:135:BMIN")
  field(DOL6, "XCOR:LI21:135:BMIN")
  field(LNK1, "XCOR:LI21:135:BMAGX.HOPR")
  field(LNK2, "XCOR:LI21:135:BMAGY.HOPR")
  field(LNK3, "XCOR:LI21:135:BLEM.HOPR")
  field(LNK4, "XCOR:LI21:135:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI21:135:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI21:135:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:135:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:135:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI21:135:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI21:135:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI21:135:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:135:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:135:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:135:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:135:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:135:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI21:135:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI21:135:EDES NPP MS")
  field(INPB, "XCOR:LI21:135:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI21:165:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI21:165:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI21:165:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI21:165:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI21:165:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI21:165:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI21:165:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI21:165:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI21:165:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI21:165:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI21:165:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI21:165:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI21:165:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI21:165:EDES.PROC PP")
    field(LNK2, "XCOR:LI21:165:EACT.PROC PP")
    field(LNK3, "XCOR:LI21:165:EERR.DISA PP")
    field(LNK4, "XCOR:LI21:165:ECON.PROC PP")
    field(LNK5, "XCOR:LI21:165:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI21:165:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI21:165:BLEM.PROC PP")
    field(LNK8, "XCOR:LI21:165:BMOD.PROC PP")
    field(LNK9, "XCOR:LI21:165:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI21:165:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI21:165:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI21:165:BMAX")
  field(DOL2, "XCOR:LI21:165:BMAX")
  field(DOL3, "XCOR:LI21:165:BMAX")
  field(DOL4, "XCOR:LI21:165:BMIN")
  field(DOL5, "XCOR:LI21:165:BMIN")
  field(DOL6, "XCOR:LI21:165:BMIN")
  field(LNK1, "XCOR:LI21:165:BMAGX.HOPR")
  field(LNK2, "XCOR:LI21:165:BMAGY.HOPR")
  field(LNK3, "XCOR:LI21:165:BLEM.HOPR")
  field(LNK4, "XCOR:LI21:165:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI21:165:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI21:165:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:165:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:165:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI21:165:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI21:165:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI21:165:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:165:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:165:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:165:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:165:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:165:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI21:165:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI21:165:EDES NPP MS")
  field(INPB, "XCOR:LI21:165:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI21:191:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI21:191:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI21:191:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI21:191:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI21:191:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI21:191:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI21:191:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI21:191:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI21:191:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI21:191:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI21:191:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI21:191:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI21:191:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI21:191:EDES.PROC PP")
    field(LNK2, "XCOR:LI21:191:EACT.PROC PP")
    field(LNK3, "XCOR:LI21:191:EERR.DISA PP")
    field(LNK4, "XCOR:LI21:191:ECON.PROC PP")
    field(LNK5, "XCOR:LI21:191:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI21:191:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI21:191:BLEM.PROC PP")
    field(LNK8, "XCOR:LI21:191:BMOD.PROC PP")
    field(LNK9, "XCOR:LI21:191:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI21:191:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI21:191:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI21:191:BMAX")
  field(DOL2, "XCOR:LI21:191:BMAX")
  field(DOL3, "XCOR:LI21:191:BMAX")
  field(DOL4, "XCOR:LI21:191:BMIN")
  field(DOL5, "XCOR:LI21:191:BMIN")
  field(DOL6, "XCOR:LI21:191:BMIN")
  field(LNK1, "XCOR:LI21:191:BMAGX.HOPR")
  field(LNK2, "XCOR:LI21:191:BMAGY.HOPR")
  field(LNK3, "XCOR:LI21:191:BLEM.HOPR")
  field(LNK4, "XCOR:LI21:191:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI21:191:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI21:191:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:191:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:191:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI21:191:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI21:191:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI21:191:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:191:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:191:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:191:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:191:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:191:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI21:191:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI21:191:EDES NPP MS")
  field(INPB, "XCOR:LI21:191:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI21:275:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI21:275:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI21:275:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI21:275:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI21:275:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI21:275:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI21:275:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI21:275:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI21:275:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI21:275:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI21:275:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI21:275:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI21:275:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI21:275:EDES.PROC PP")
    field(LNK2, "XCOR:LI21:275:EACT.PROC PP")
    field(LNK3, "XCOR:LI21:275:EERR.DISA PP")
    field(LNK4, "XCOR:LI21:275:ECON.PROC PP")
    field(LNK5, "XCOR:LI21:275:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI21:275:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI21:275:BLEM.PROC PP")
    field(LNK8, "XCOR:LI21:275:BMOD.PROC PP")
    field(LNK9, "XCOR:LI21:275:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI21:275:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI21:275:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI21:275:BMAX")
  field(DOL2, "XCOR:LI21:275:BMAX")
  field(DOL3, "XCOR:LI21:275:BMAX")
  field(DOL4, "XCOR:LI21:275:BMIN")
  field(DOL5, "XCOR:LI21:275:BMIN")
  field(DOL6, "XCOR:LI21:275:BMIN")
  field(LNK1, "XCOR:LI21:275:BMAGX.HOPR")
  field(LNK2, "XCOR:LI21:275:BMAGY.HOPR")
  field(LNK3, "XCOR:LI21:275:BLEM.HOPR")
  field(LNK4, "XCOR:LI21:275:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI21:275:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI21:275:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:275:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:275:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI21:275:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI21:275:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI21:275:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:275:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:275:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:275:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:275:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:275:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI21:275:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI21:275:EDES NPP MS")
  field(INPB, "XCOR:LI21:275:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI21:302:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI21:302:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI21:302:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI21:302:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI21:302:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI21:302:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI21:302:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI21:302:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI21:302:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI21:302:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI21:302:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI21:302:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI21:302:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI21:302:EDES.PROC PP")
    field(LNK2, "XCOR:LI21:302:EACT.PROC PP")
    field(LNK3, "XCOR:LI21:302:EERR.DISA PP")
    field(LNK4, "XCOR:LI21:302:ECON.PROC PP")
    field(LNK5, "XCOR:LI21:302:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI21:302:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI21:302:BLEM.PROC PP")
    field(LNK8, "XCOR:LI21:302:BMOD.PROC PP")
    field(LNK9, "XCOR:LI21:302:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI21:302:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI21:302:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI21:302:BMAX")
  field(DOL2, "XCOR:LI21:302:BMAX")
  field(DOL3, "XCOR:LI21:302:BMAX")
  field(DOL4, "XCOR:LI21:302:BMIN")
  field(DOL5, "XCOR:LI21:302:BMIN")
  field(DOL6, "XCOR:LI21:302:BMIN")
  field(LNK1, "XCOR:LI21:302:BMAGX.HOPR")
  field(LNK2, "XCOR:LI21:302:BMAGY.HOPR")
  field(LNK3, "XCOR:LI21:302:BLEM.HOPR")
  field(LNK4, "XCOR:LI21:302:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI21:302:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI21:302:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:302:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:302:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI21:302:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI21:302:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI21:302:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:302:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:302:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:302:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:302:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:302:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI21:302:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI21:302:EDES NPP MS")
  field(INPB, "XCOR:LI21:302:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI21:325:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI21:325:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI21:325:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI21:325:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI21:325:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI21:325:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI21:325:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI21:325:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI21:325:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI21:325:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI21:325:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI21:325:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI21:325:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI21:325:EDES.PROC PP")
    field(LNK2, "XCOR:LI21:325:EACT.PROC PP")
    field(LNK3, "XCOR:LI21:325:EERR.DISA PP")
    field(LNK4, "XCOR:LI21:325:ECON.PROC PP")
    field(LNK5, "XCOR:LI21:325:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI21:325:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI21:325:BLEM.PROC PP")
    field(LNK8, "XCOR:LI21:325:BMOD.PROC PP")
    field(LNK9, "XCOR:LI21:325:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI21:325:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI21:325:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI21:325:BMAX")
  field(DOL2, "XCOR:LI21:325:BMAX")
  field(DOL3, "XCOR:LI21:325:BMAX")
  field(DOL4, "XCOR:LI21:325:BMIN")
  field(DOL5, "XCOR:LI21:325:BMIN")
  field(DOL6, "XCOR:LI21:325:BMIN")
  field(LNK1, "XCOR:LI21:325:BMAGX.HOPR")
  field(LNK2, "XCOR:LI21:325:BMAGY.HOPR")
  field(LNK3, "XCOR:LI21:325:BLEM.HOPR")
  field(LNK4, "XCOR:LI21:325:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI21:325:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI21:325:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:325:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI21:325:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI21:325:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI21:325:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI21:325:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:325:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:325:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:325:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI21:325:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI21:325:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI21:325:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI21:325:EDES NPP MS")
  field(INPB, "XCOR:LI21:325:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI21:174:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI21:174:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI21:174:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI21:174:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI21:174:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI21:174:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI21:174:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI21:174:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI21:174:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI21:174:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI21:174:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI21:174:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI21:174:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI21:174:EDES.PROC PP")
    field(LNK2, "YCOR:LI21:174:EACT.PROC PP")
    field(LNK3, "YCOR:LI21:174:EERR.DISA PP")
    field(LNK4, "YCOR:LI21:174:ECON.PROC PP")
    field(LNK5, "YCOR:LI21:174:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI21:174:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI21:174:BLEM.PROC PP")
    field(LNK8, "YCOR:LI21:174:BMOD.PROC PP")
    field(LNK9, "YCOR:LI21:174:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI21:174:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI21:174:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI21:174:BMAX")
  field(DOL2, "YCOR:LI21:174:BMAX")
  field(DOL3, "YCOR:LI21:174:BMAX")
  field(DOL4, "YCOR:LI21:174:BMIN")
  field(DOL5, "YCOR:LI21:174:BMIN")
  field(DOL6, "YCOR:LI21:174:BMIN")
  field(LNK1, "YCOR:LI21:174:BMAGX.HOPR")
  field(LNK2, "YCOR:LI21:174:BMAGY.HOPR")
  field(LNK3, "YCOR:LI21:174:BLEM.HOPR")
  field(LNK4, "YCOR:LI21:174:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI21:174:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI21:174:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:174:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:174:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI21:174:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI21:174:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI21:174:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:174:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:174:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:174:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:174:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:174:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI21:174:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI21:174:EDES NPP MS")
  field(INPB, "YCOR:LI21:174:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI21:403:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI21:403:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI21:403:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI21:403:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI21:403:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI21:403:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI21:403:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI21:403:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI21:403:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI21:403:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI21:403:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI21:403:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI21:403:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI21:403:EDES.PROC PP")
    field(LNK2, "YCOR:LI21:403:EACT.PROC PP")
    field(LNK3, "YCOR:LI21:403:EERR.DISA PP")
    field(LNK4, "YCOR:LI21:403:ECON.PROC PP")
    field(LNK5, "YCOR:LI21:403:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI21:403:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI21:403:BLEM.PROC PP")
    field(LNK8, "YCOR:LI21:403:BMOD.PROC PP")
    field(LNK9, "YCOR:LI21:403:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI21:403:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI21:403:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI21:403:BMAX")
  field(DOL2, "YCOR:LI21:403:BMAX")
  field(DOL3, "YCOR:LI21:403:BMAX")
  field(DOL4, "YCOR:LI21:403:BMIN")
  field(DOL5, "YCOR:LI21:403:BMIN")
  field(DOL6, "YCOR:LI21:403:BMIN")
  field(LNK1, "YCOR:LI21:403:BMAGX.HOPR")
  field(LNK2, "YCOR:LI21:403:BMAGY.HOPR")
  field(LNK3, "YCOR:LI21:403:BLEM.HOPR")
  field(LNK4, "YCOR:LI21:403:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI21:403:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI21:403:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:403:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:403:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI21:403:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI21:403:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI21:403:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:403:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:403:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:403:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:403:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:403:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI21:403:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI21:403:EDES NPP MS")
  field(INPB, "YCOR:LI21:403:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI21:503:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI21:503:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI21:503:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI21:503:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI21:503:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI21:503:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI21:503:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI21:503:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI21:503:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI21:503:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI21:503:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI21:503:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI21:503:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI21:503:EDES.PROC PP")
    field(LNK2, "YCOR:LI21:503:EACT.PROC PP")
    field(LNK3, "YCOR:LI21:503:EERR.DISA PP")
    field(LNK4, "YCOR:LI21:503:ECON.PROC PP")
    field(LNK5, "YCOR:LI21:503:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI21:503:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI21:503:BLEM.PROC PP")
    field(LNK8, "YCOR:LI21:503:BMOD.PROC PP")
    field(LNK9, "YCOR:LI21:503:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI21:503:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI21:503:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI21:503:BMAX")
  field(DOL2, "YCOR:LI21:503:BMAX")
  field(DOL3, "YCOR:LI21:503:BMAX")
  field(DOL4, "YCOR:LI21:503:BMIN")
  field(DOL5, "YCOR:LI21:503:BMIN")
  field(DOL6, "YCOR:LI21:503:BMIN")
  field(LNK1, "YCOR:LI21:503:BMAGX.HOPR")
  field(LNK2, "YCOR:LI21:503:BMAGY.HOPR")
  field(LNK3, "YCOR:LI21:503:BLEM.HOPR")
  field(LNK4, "YCOR:LI21:503:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI21:503:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI21:503:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:503:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:503:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI21:503:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI21:503:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI21:503:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:503:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:503:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:503:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:503:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:503:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI21:503:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI21:503:EDES NPP MS")
  field(INPB, "YCOR:LI21:503:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI21:603:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI21:603:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI21:603:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI21:603:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI21:603:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI21:603:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI21:603:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI21:603:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI21:603:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI21:603:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI21:603:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI21:603:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI21:603:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI21:603:EDES.PROC PP")
    field(LNK2, "YCOR:LI21:603:EACT.PROC PP")
    field(LNK3, "YCOR:LI21:603:EERR.DISA PP")
    field(LNK4, "YCOR:LI21:603:ECON.PROC PP")
    field(LNK5, "YCOR:LI21:603:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI21:603:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI21:603:BLEM.PROC PP")
    field(LNK8, "YCOR:LI21:603:BMOD.PROC PP")
    field(LNK9, "YCOR:LI21:603:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI21:603:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI21:603:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI21:603:BMAX")
  field(DOL2, "YCOR:LI21:603:BMAX")
  field(DOL3, "YCOR:LI21:603:BMAX")
  field(DOL4, "YCOR:LI21:603:BMIN")
  field(DOL5, "YCOR:LI21:603:BMIN")
  field(DOL6, "YCOR:LI21:603:BMIN")
  field(LNK1, "YCOR:LI21:603:BMAGX.HOPR")
  field(LNK2, "YCOR:LI21:603:BMAGY.HOPR")
  field(LNK3, "YCOR:LI21:603:BLEM.HOPR")
  field(LNK4, "YCOR:LI21:603:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI21:603:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI21:603:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:603:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:603:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI21:603:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI21:603:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI21:603:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:603:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:603:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:603:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:603:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:603:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI21:603:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI21:603:EDES NPP MS")
  field(INPB, "YCOR:LI21:603:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI21:703:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI21:703:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI21:703:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI21:703:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI21:703:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI21:703:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI21:703:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI21:703:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI21:703:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI21:703:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI21:703:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI21:703:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI21:703:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI21:703:EDES.PROC PP")
    field(LNK2, "YCOR:LI21:703:EACT.PROC PP")
    field(LNK3, "YCOR:LI21:703:EERR.DISA PP")
    field(LNK4, "YCOR:LI21:703:ECON.PROC PP")
    field(LNK5, "YCOR:LI21:703:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI21:703:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI21:703:BLEM.PROC PP")
    field(LNK8, "YCOR:LI21:703:BMOD.PROC PP")
    field(LNK9, "YCOR:LI21:703:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI21:703:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI21:703:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI21:703:BMAX")
  field(DOL2, "YCOR:LI21:703:BMAX")
  field(DOL3, "YCOR:LI21:703:BMAX")
  field(DOL4, "YCOR:LI21:703:BMIN")
  field(DOL5, "YCOR:LI21:703:BMIN")
  field(DOL6, "YCOR:LI21:703:BMIN")
  field(LNK1, "YCOR:LI21:703:BMAGX.HOPR")
  field(LNK2, "YCOR:LI21:703:BMAGY.HOPR")
  field(LNK3, "YCOR:LI21:703:BLEM.HOPR")
  field(LNK4, "YCOR:LI21:703:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI21:703:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI21:703:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:703:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:703:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI21:703:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI21:703:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI21:703:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:703:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:703:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:703:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:703:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:703:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI21:703:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI21:703:EDES NPP MS")
  field(INPB, "YCOR:LI21:703:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI21:803:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI21:803:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI21:803:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI21:803:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI21:803:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI21:803:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI21:803:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI21:803:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI21:803:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI21:803:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI21:803:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI21:803:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI21:803:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI21:803:EDES.PROC PP")
    field(LNK2, "YCOR:LI21:803:EACT.PROC PP")
    field(LNK3, "YCOR:LI21:803:EERR.DISA PP")
    field(LNK4, "YCOR:LI21:803:ECON.PROC PP")
    field(LNK5, "YCOR:LI21:803:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI21:803:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI21:803:BLEM.PROC PP")
    field(LNK8, "YCOR:LI21:803:BMOD.PROC PP")
    field(LNK9, "YCOR:LI21:803:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI21:803:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI21:803:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI21:803:BMAX")
  field(DOL2, "YCOR:LI21:803:BMAX")
  field(DOL3, "YCOR:LI21:803:BMAX")
  field(DOL4, "YCOR:LI21:803:BMIN")
  field(DOL5, "YCOR:LI21:803:BMIN")
  field(DOL6, "YCOR:LI21:803:BMIN")
  field(LNK1, "YCOR:LI21:803:BMAGX.HOPR")
  field(LNK2, "YCOR:LI21:803:BMAGY.HOPR")
  field(LNK3, "YCOR:LI21:803:BLEM.HOPR")
  field(LNK4, "YCOR:LI21:803:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI21:803:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI21:803:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:803:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:803:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI21:803:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI21:803:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI21:803:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:803:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:803:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:803:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:803:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:803:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI21:803:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI21:803:EDES NPP MS")
  field(INPB, "YCOR:LI21:803:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI21:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI21:900:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI21:900:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI21:900:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI21:900:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI21:900:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI21:900:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI21:900:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI21:900:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI21:900:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI21:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI21:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI21:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI21:900:EDES.PROC PP")
    field(LNK2, "YCOR:LI21:900:EACT.PROC PP")
    field(LNK3, "YCOR:LI21:900:EERR.DISA PP")
    field(LNK4, "YCOR:LI21:900:ECON.PROC PP")
    field(LNK5, "YCOR:LI21:900:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI21:900:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI21:900:BLEM.PROC PP")
    field(LNK8, "YCOR:LI21:900:BMOD.PROC PP")
    field(LNK9, "YCOR:LI21:900:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI21:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI21:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI21:900:BMAX")
  field(DOL2, "YCOR:LI21:900:BMAX")
  field(DOL3, "YCOR:LI21:900:BMAX")
  field(DOL4, "YCOR:LI21:900:BMIN")
  field(DOL5, "YCOR:LI21:900:BMIN")
  field(DOL6, "YCOR:LI21:900:BMIN")
  field(LNK1, "YCOR:LI21:900:BMAGX.HOPR")
  field(LNK2, "YCOR:LI21:900:BMAGY.HOPR")
  field(LNK3, "YCOR:LI21:900:BLEM.HOPR")
  field(LNK4, "YCOR:LI21:900:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI21:900:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI21:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI21:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI21:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI21:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI21:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI21:900:EDES NPP MS")
  field(INPB, "YCOR:LI21:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI21:102:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI21:102:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI21:102:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI21:102:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI21:102:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI21:102:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI21:102:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI21:102:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI21:102:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI21:102:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI21:102:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI21:102:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI21:102:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI21:102:EDES.PROC PP")
    field(LNK2, "YCOR:LI21:102:EACT.PROC PP")
    field(LNK3, "YCOR:LI21:102:EERR.DISA PP")
    field(LNK4, "YCOR:LI21:102:ECON.PROC PP")
    field(LNK5, "YCOR:LI21:102:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI21:102:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI21:102:BLEM.PROC PP")
    field(LNK8, "YCOR:LI21:102:BMOD.PROC PP")
    field(LNK9, "YCOR:LI21:102:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI21:102:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI21:102:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI21:102:BMAX")
  field(DOL2, "YCOR:LI21:102:BMAX")
  field(DOL3, "YCOR:LI21:102:BMAX")
  field(DOL4, "YCOR:LI21:102:BMIN")
  field(DOL5, "YCOR:LI21:102:BMIN")
  field(DOL6, "YCOR:LI21:102:BMIN")
  field(LNK1, "YCOR:LI21:102:BMAGX.HOPR")
  field(LNK2, "YCOR:LI21:102:BMAGY.HOPR")
  field(LNK3, "YCOR:LI21:102:BLEM.HOPR")
  field(LNK4, "YCOR:LI21:102:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI21:102:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI21:102:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:102:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:102:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI21:102:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI21:102:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI21:102:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:102:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:102:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:102:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:102:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:102:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI21:102:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI21:102:EDES NPP MS")
  field(INPB, "YCOR:LI21:102:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI21:136:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI21:136:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI21:136:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI21:136:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI21:136:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI21:136:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI21:136:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI21:136:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI21:136:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI21:136:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI21:136:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI21:136:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI21:136:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI21:136:EDES.PROC PP")
    field(LNK2, "YCOR:LI21:136:EACT.PROC PP")
    field(LNK3, "YCOR:LI21:136:EERR.DISA PP")
    field(LNK4, "YCOR:LI21:136:ECON.PROC PP")
    field(LNK5, "YCOR:LI21:136:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI21:136:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI21:136:BLEM.PROC PP")
    field(LNK8, "YCOR:LI21:136:BMOD.PROC PP")
    field(LNK9, "YCOR:LI21:136:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI21:136:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI21:136:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI21:136:BMAX")
  field(DOL2, "YCOR:LI21:136:BMAX")
  field(DOL3, "YCOR:LI21:136:BMAX")
  field(DOL4, "YCOR:LI21:136:BMIN")
  field(DOL5, "YCOR:LI21:136:BMIN")
  field(DOL6, "YCOR:LI21:136:BMIN")
  field(LNK1, "YCOR:LI21:136:BMAGX.HOPR")
  field(LNK2, "YCOR:LI21:136:BMAGY.HOPR")
  field(LNK3, "YCOR:LI21:136:BLEM.HOPR")
  field(LNK4, "YCOR:LI21:136:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI21:136:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI21:136:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:136:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:136:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI21:136:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI21:136:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI21:136:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:136:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:136:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:136:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:136:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:136:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI21:136:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI21:136:EDES NPP MS")
  field(INPB, "YCOR:LI21:136:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI21:166:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI21:166:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI21:166:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI21:166:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI21:166:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI21:166:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI21:166:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI21:166:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI21:166:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI21:166:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI21:166:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI21:166:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI21:166:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI21:166:EDES.PROC PP")
    field(LNK2, "YCOR:LI21:166:EACT.PROC PP")
    field(LNK3, "YCOR:LI21:166:EERR.DISA PP")
    field(LNK4, "YCOR:LI21:166:ECON.PROC PP")
    field(LNK5, "YCOR:LI21:166:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI21:166:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI21:166:BLEM.PROC PP")
    field(LNK8, "YCOR:LI21:166:BMOD.PROC PP")
    field(LNK9, "YCOR:LI21:166:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI21:166:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI21:166:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI21:166:BMAX")
  field(DOL2, "YCOR:LI21:166:BMAX")
  field(DOL3, "YCOR:LI21:166:BMAX")
  field(DOL4, "YCOR:LI21:166:BMIN")
  field(DOL5, "YCOR:LI21:166:BMIN")
  field(DOL6, "YCOR:LI21:166:BMIN")
  field(LNK1, "YCOR:LI21:166:BMAGX.HOPR")
  field(LNK2, "YCOR:LI21:166:BMAGY.HOPR")
  field(LNK3, "YCOR:LI21:166:BLEM.HOPR")
  field(LNK4, "YCOR:LI21:166:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI21:166:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI21:166:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:166:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:166:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI21:166:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI21:166:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI21:166:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:166:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:166:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:166:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:166:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:166:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI21:166:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI21:166:EDES NPP MS")
  field(INPB, "YCOR:LI21:166:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI21:192:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI21:192:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI21:192:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI21:192:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI21:192:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI21:192:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI21:192:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI21:192:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI21:192:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI21:192:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI21:192:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI21:192:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI21:192:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI21:192:EDES.PROC PP")
    field(LNK2, "YCOR:LI21:192:EACT.PROC PP")
    field(LNK3, "YCOR:LI21:192:EERR.DISA PP")
    field(LNK4, "YCOR:LI21:192:ECON.PROC PP")
    field(LNK5, "YCOR:LI21:192:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI21:192:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI21:192:BLEM.PROC PP")
    field(LNK8, "YCOR:LI21:192:BMOD.PROC PP")
    field(LNK9, "YCOR:LI21:192:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI21:192:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI21:192:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI21:192:BMAX")
  field(DOL2, "YCOR:LI21:192:BMAX")
  field(DOL3, "YCOR:LI21:192:BMAX")
  field(DOL4, "YCOR:LI21:192:BMIN")
  field(DOL5, "YCOR:LI21:192:BMIN")
  field(DOL6, "YCOR:LI21:192:BMIN")
  field(LNK1, "YCOR:LI21:192:BMAGX.HOPR")
  field(LNK2, "YCOR:LI21:192:BMAGY.HOPR")
  field(LNK3, "YCOR:LI21:192:BLEM.HOPR")
  field(LNK4, "YCOR:LI21:192:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI21:192:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI21:192:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:192:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:192:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI21:192:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI21:192:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI21:192:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:192:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:192:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:192:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:192:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:192:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI21:192:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI21:192:EDES NPP MS")
  field(INPB, "YCOR:LI21:192:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI21:276:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI21:276:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI21:276:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI21:276:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI21:276:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI21:276:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI21:276:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI21:276:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI21:276:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI21:276:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI21:276:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI21:276:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI21:276:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI21:276:EDES.PROC PP")
    field(LNK2, "YCOR:LI21:276:EACT.PROC PP")
    field(LNK3, "YCOR:LI21:276:EERR.DISA PP")
    field(LNK4, "YCOR:LI21:276:ECON.PROC PP")
    field(LNK5, "YCOR:LI21:276:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI21:276:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI21:276:BLEM.PROC PP")
    field(LNK8, "YCOR:LI21:276:BMOD.PROC PP")
    field(LNK9, "YCOR:LI21:276:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI21:276:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI21:276:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI21:276:BMAX")
  field(DOL2, "YCOR:LI21:276:BMAX")
  field(DOL3, "YCOR:LI21:276:BMAX")
  field(DOL4, "YCOR:LI21:276:BMIN")
  field(DOL5, "YCOR:LI21:276:BMIN")
  field(DOL6, "YCOR:LI21:276:BMIN")
  field(LNK1, "YCOR:LI21:276:BMAGX.HOPR")
  field(LNK2, "YCOR:LI21:276:BMAGY.HOPR")
  field(LNK3, "YCOR:LI21:276:BLEM.HOPR")
  field(LNK4, "YCOR:LI21:276:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI21:276:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI21:276:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:276:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:276:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI21:276:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI21:276:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI21:276:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:276:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:276:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:276:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:276:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:276:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI21:276:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI21:276:EDES NPP MS")
  field(INPB, "YCOR:LI21:276:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI21:303:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI21:303:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI21:303:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI21:303:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI21:303:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI21:303:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI21:303:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI21:303:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI21:303:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI21:303:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI21:303:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI21:303:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI21:303:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI21:303:EDES.PROC PP")
    field(LNK2, "YCOR:LI21:303:EACT.PROC PP")
    field(LNK3, "YCOR:LI21:303:EERR.DISA PP")
    field(LNK4, "YCOR:LI21:303:ECON.PROC PP")
    field(LNK5, "YCOR:LI21:303:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI21:303:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI21:303:BLEM.PROC PP")
    field(LNK8, "YCOR:LI21:303:BMOD.PROC PP")
    field(LNK9, "YCOR:LI21:303:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI21:303:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI21:303:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI21:303:BMAX")
  field(DOL2, "YCOR:LI21:303:BMAX")
  field(DOL3, "YCOR:LI21:303:BMAX")
  field(DOL4, "YCOR:LI21:303:BMIN")
  field(DOL5, "YCOR:LI21:303:BMIN")
  field(DOL6, "YCOR:LI21:303:BMIN")
  field(LNK1, "YCOR:LI21:303:BMAGX.HOPR")
  field(LNK2, "YCOR:LI21:303:BMAGY.HOPR")
  field(LNK3, "YCOR:LI21:303:BLEM.HOPR")
  field(LNK4, "YCOR:LI21:303:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI21:303:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI21:303:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:303:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:303:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI21:303:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI21:303:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI21:303:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:303:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:303:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:303:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:303:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:303:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI21:303:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI21:303:EDES NPP MS")
  field(INPB, "YCOR:LI21:303:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI21:325:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI21:325:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI21:325:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI21:325:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI21:325:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI21:325:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI21:325:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI21:325:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI21:325:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI21:325:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI21:325:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI21:325:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI21:325:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI21:325:EDES.PROC PP")
    field(LNK2, "YCOR:LI21:325:EACT.PROC PP")
    field(LNK3, "YCOR:LI21:325:EERR.DISA PP")
    field(LNK4, "YCOR:LI21:325:ECON.PROC PP")
    field(LNK5, "YCOR:LI21:325:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI21:325:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI21:325:BLEM.PROC PP")
    field(LNK8, "YCOR:LI21:325:BMOD.PROC PP")
    field(LNK9, "YCOR:LI21:325:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI21:325:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI21:325:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI21:325:BMAX")
  field(DOL2, "YCOR:LI21:325:BMAX")
  field(DOL3, "YCOR:LI21:325:BMAX")
  field(DOL4, "YCOR:LI21:325:BMIN")
  field(DOL5, "YCOR:LI21:325:BMIN")
  field(DOL6, "YCOR:LI21:325:BMIN")
  field(LNK1, "YCOR:LI21:325:BMAGX.HOPR")
  field(LNK2, "YCOR:LI21:325:BMAGY.HOPR")
  field(LNK3, "YCOR:LI21:325:BLEM.HOPR")
  field(LNK4, "YCOR:LI21:325:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI21:325:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI21:325:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:325:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI21:325:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI21:325:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI21:325:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI21:325:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:325:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:325:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:325:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI21:325:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI21:325:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI21:325:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI21:325:EDES NPP MS")
  field(INPB, "YCOR:LI21:325:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LI22:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "LGPS:LI22:2:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LI22:2:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LI22:2:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LI22:2:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LI22:2:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LI22:2:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LI22:2:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LI22:2:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LI22:2:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LI22:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LI22:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LI22:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LI22:2:EDES.PROC PP")
    field(LNK2, "LGPS:LI22:2:EACT.PROC PP")
    field(LNK3, "LGPS:LI22:2:EERR.DISA PP")
    field(LNK4, "LGPS:LI22:2:ECON.PROC PP")
    field(LNK5, "LGPS:LI22:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:LI22:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:LI22:2:BLEM.PROC PP")
    field(LNK8, "LGPS:LI22:2:BMOD.PROC PP")
    field(LNK9, "LGPS:LI22:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LI22:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LI22:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LI22:2:BMAX")
  field(DOL2, "LGPS:LI22:2:BMAX")
  field(DOL3, "LGPS:LI22:2:BMAX")
  field(DOL4, "LGPS:LI22:2:BMIN")
  field(DOL5, "LGPS:LI22:2:BMIN")
  field(DOL6, "LGPS:LI22:2:BMIN")
  field(LNK1, "LGPS:LI22:2:BMAGX.HOPR")
  field(LNK2, "LGPS:LI22:2:BMAGY.HOPR")
  field(LNK3, "LGPS:LI22:2:BLEM.HOPR")
  field(LNK4, "LGPS:LI22:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LI22:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LI22:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LI22:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LI22:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LI22:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LI22:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LI22:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI22:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI22:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI22:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI22:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI22:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LI22:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LI22:2:EDES NPP MS")
  field(INPB, "LGPS:LI22:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:LI22:929:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "KICK:LI22:929:1:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:LI22:929:1:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:LI22:929:1:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:LI22:929:1:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:LI22:929:1:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:LI22:929:1:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:LI22:929:1:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:LI22:929:1:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:LI22:929:1:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:LI22:929:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:LI22:929:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:LI22:929:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:LI22:929:1:EDES.PROC PP")
    field(LNK2, "KICK:LI22:929:1:EACT.PROC PP")
    field(LNK3, "KICK:LI22:929:1:EERR.DISA PP")
    field(LNK4, "KICK:LI22:929:1:ECON.PROC PP")
    field(LNK5, "KICK:LI22:929:1:BMAGX.PROC PP")
    field(LNK6, "KICK:LI22:929:1:BMAGY.PROC PP")
    field(LNK7, "KICK:LI22:929:1:BLEM.PROC PP")
    field(LNK8, "KICK:LI22:929:1:BMOD.PROC PP")
    field(LNK9, "KICK:LI22:929:1:EDESSAVE.PROC PP")
    field(LNKA, "KICK:LI22:929:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:LI22:929:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:LI22:929:1:BMAX")
  field(DOL2, "KICK:LI22:929:1:BMAX")
  field(DOL3, "KICK:LI22:929:1:BMAX")
  field(DOL4, "KICK:LI22:929:1:BMIN")
  field(DOL5, "KICK:LI22:929:1:BMIN")
  field(DOL6, "KICK:LI22:929:1:BMIN")
  field(LNK1, "KICK:LI22:929:1:BMAGX.HOPR")
  field(LNK2, "KICK:LI22:929:1:BMAGY.HOPR")
  field(LNK3, "KICK:LI22:929:1:BLEM.HOPR")
  field(LNK4, "KICK:LI22:929:1:BMAGX.LOPR PP")
  field(LNK5, "KICK:LI22:929:1:BMAGY.LOPR PP")
  field(LNK6, "KICK:LI22:929:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:LI22:929:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:LI22:929:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:LI22:929:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:LI22:929:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:LI22:929:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI22:929:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI22:929:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI22:929:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI22:929:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI22:929:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:LI22:929:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:LI22:929:1:EDES NPP MS")
  field(INPB, "KICK:LI22:929:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:LI22:929:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "KICK:LI22:929:2:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:LI22:929:2:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:LI22:929:2:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:LI22:929:2:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:LI22:929:2:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:LI22:929:2:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:LI22:929:2:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:LI22:929:2:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:LI22:929:2:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:LI22:929:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:LI22:929:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:LI22:929:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:LI22:929:2:EDES.PROC PP")
    field(LNK2, "KICK:LI22:929:2:EACT.PROC PP")
    field(LNK3, "KICK:LI22:929:2:EERR.DISA PP")
    field(LNK4, "KICK:LI22:929:2:ECON.PROC PP")
    field(LNK5, "KICK:LI22:929:2:BMAGX.PROC PP")
    field(LNK6, "KICK:LI22:929:2:BMAGY.PROC PP")
    field(LNK7, "KICK:LI22:929:2:BLEM.PROC PP")
    field(LNK8, "KICK:LI22:929:2:BMOD.PROC PP")
    field(LNK9, "KICK:LI22:929:2:EDESSAVE.PROC PP")
    field(LNKA, "KICK:LI22:929:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:LI22:929:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:LI22:929:2:BMAX")
  field(DOL2, "KICK:LI22:929:2:BMAX")
  field(DOL3, "KICK:LI22:929:2:BMAX")
  field(DOL4, "KICK:LI22:929:2:BMIN")
  field(DOL5, "KICK:LI22:929:2:BMIN")
  field(DOL6, "KICK:LI22:929:2:BMIN")
  field(LNK1, "KICK:LI22:929:2:BMAGX.HOPR")
  field(LNK2, "KICK:LI22:929:2:BMAGY.HOPR")
  field(LNK3, "KICK:LI22:929:2:BLEM.HOPR")
  field(LNK4, "KICK:LI22:929:2:BMAGX.LOPR PP")
  field(LNK5, "KICK:LI22:929:2:BMAGY.LOPR PP")
  field(LNK6, "KICK:LI22:929:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:LI22:929:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:LI22:929:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:LI22:929:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:LI22:929:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:LI22:929:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI22:929:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI22:929:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI22:929:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI22:929:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI22:929:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:LI22:929:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:LI22:929:2:EDES NPP MS")
  field(INPB, "KICK:LI22:929:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:LI22:957:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "KICK:LI22:957:1:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:LI22:957:1:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:LI22:957:1:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:LI22:957:1:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:LI22:957:1:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:LI22:957:1:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:LI22:957:1:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:LI22:957:1:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:LI22:957:1:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:LI22:957:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:LI22:957:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:LI22:957:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:LI22:957:1:EDES.PROC PP")
    field(LNK2, "KICK:LI22:957:1:EACT.PROC PP")
    field(LNK3, "KICK:LI22:957:1:EERR.DISA PP")
    field(LNK4, "KICK:LI22:957:1:ECON.PROC PP")
    field(LNK5, "KICK:LI22:957:1:BMAGX.PROC PP")
    field(LNK6, "KICK:LI22:957:1:BMAGY.PROC PP")
    field(LNK7, "KICK:LI22:957:1:BLEM.PROC PP")
    field(LNK8, "KICK:LI22:957:1:BMOD.PROC PP")
    field(LNK9, "KICK:LI22:957:1:EDESSAVE.PROC PP")
    field(LNKA, "KICK:LI22:957:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:LI22:957:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:LI22:957:1:BMAX")
  field(DOL2, "KICK:LI22:957:1:BMAX")
  field(DOL3, "KICK:LI22:957:1:BMAX")
  field(DOL4, "KICK:LI22:957:1:BMIN")
  field(DOL5, "KICK:LI22:957:1:BMIN")
  field(DOL6, "KICK:LI22:957:1:BMIN")
  field(LNK1, "KICK:LI22:957:1:BMAGX.HOPR")
  field(LNK2, "KICK:LI22:957:1:BMAGY.HOPR")
  field(LNK3, "KICK:LI22:957:1:BLEM.HOPR")
  field(LNK4, "KICK:LI22:957:1:BMAGX.LOPR PP")
  field(LNK5, "KICK:LI22:957:1:BMAGY.LOPR PP")
  field(LNK6, "KICK:LI22:957:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:LI22:957:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:LI22:957:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:LI22:957:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:LI22:957:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:LI22:957:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI22:957:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI22:957:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI22:957:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI22:957:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI22:957:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:LI22:957:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:LI22:957:1:EDES NPP MS")
  field(INPB, "KICK:LI22:957:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:LI22:957:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "KICK:LI22:957:2:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:LI22:957:2:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:LI22:957:2:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:LI22:957:2:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:LI22:957:2:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:LI22:957:2:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:LI22:957:2:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:LI22:957:2:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:LI22:957:2:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:LI22:957:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:LI22:957:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:LI22:957:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:LI22:957:2:EDES.PROC PP")
    field(LNK2, "KICK:LI22:957:2:EACT.PROC PP")
    field(LNK3, "KICK:LI22:957:2:EERR.DISA PP")
    field(LNK4, "KICK:LI22:957:2:ECON.PROC PP")
    field(LNK5, "KICK:LI22:957:2:BMAGX.PROC PP")
    field(LNK6, "KICK:LI22:957:2:BMAGY.PROC PP")
    field(LNK7, "KICK:LI22:957:2:BLEM.PROC PP")
    field(LNK8, "KICK:LI22:957:2:BMOD.PROC PP")
    field(LNK9, "KICK:LI22:957:2:EDESSAVE.PROC PP")
    field(LNKA, "KICK:LI22:957:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:LI22:957:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:LI22:957:2:BMAX")
  field(DOL2, "KICK:LI22:957:2:BMAX")
  field(DOL3, "KICK:LI22:957:2:BMAX")
  field(DOL4, "KICK:LI22:957:2:BMIN")
  field(DOL5, "KICK:LI22:957:2:BMIN")
  field(DOL6, "KICK:LI22:957:2:BMIN")
  field(LNK1, "KICK:LI22:957:2:BMAGX.HOPR")
  field(LNK2, "KICK:LI22:957:2:BMAGY.HOPR")
  field(LNK3, "KICK:LI22:957:2:BLEM.HOPR")
  field(LNK4, "KICK:LI22:957:2:BMAGX.LOPR PP")
  field(LNK5, "KICK:LI22:957:2:BMAGY.LOPR PP")
  field(LNK6, "KICK:LI22:957:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:LI22:957:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:LI22:957:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:LI22:957:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:LI22:957:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:LI22:957:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI22:957:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI22:957:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI22:957:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LI22:957:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LI22:957:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:LI22:957:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:LI22:957:2:EDES NPP MS")
  field(INPB, "KICK:LI22:957:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI22:201:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI22:201:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI22:201:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI22:201:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI22:201:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI22:201:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI22:201:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI22:201:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI22:201:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI22:201:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI22:201:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI22:201:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI22:201:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI22:201:EDES.PROC PP")
    field(LNK2, "QUAD:LI22:201:EACT.PROC PP")
    field(LNK3, "QUAD:LI22:201:EERR.DISA PP")
    field(LNK4, "QUAD:LI22:201:ECON.PROC PP")
    field(LNK5, "QUAD:LI22:201:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI22:201:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI22:201:BLEM.PROC PP")
    field(LNK8, "QUAD:LI22:201:BMOD.PROC PP")
    field(LNK9, "QUAD:LI22:201:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI22:201:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI22:201:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI22:201:BMAX")
  field(DOL2, "QUAD:LI22:201:BMAX")
  field(DOL3, "QUAD:LI22:201:BMAX")
  field(DOL4, "QUAD:LI22:201:BMIN")
  field(DOL5, "QUAD:LI22:201:BMIN")
  field(DOL6, "QUAD:LI22:201:BMIN")
  field(LNK1, "QUAD:LI22:201:BMAGX.HOPR")
  field(LNK2, "QUAD:LI22:201:BMAGY.HOPR")
  field(LNK3, "QUAD:LI22:201:BLEM.HOPR")
  field(LNK4, "QUAD:LI22:201:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI22:201:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI22:201:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:201:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:201:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI22:201:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI22:201:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI22:201:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:201:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:201:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:201:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:201:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:201:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI22:201:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI22:201:EDES NPP MS")
  field(INPB, "QUAD:LI22:201:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI22:301:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI22:301:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI22:301:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI22:301:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI22:301:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI22:301:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI22:301:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI22:301:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI22:301:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI22:301:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI22:301:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI22:301:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI22:301:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI22:301:EDES.PROC PP")
    field(LNK2, "QUAD:LI22:301:EACT.PROC PP")
    field(LNK3, "QUAD:LI22:301:EERR.DISA PP")
    field(LNK4, "QUAD:LI22:301:ECON.PROC PP")
    field(LNK5, "QUAD:LI22:301:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI22:301:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI22:301:BLEM.PROC PP")
    field(LNK8, "QUAD:LI22:301:BMOD.PROC PP")
    field(LNK9, "QUAD:LI22:301:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI22:301:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI22:301:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI22:301:BMAX")
  field(DOL2, "QUAD:LI22:301:BMAX")
  field(DOL3, "QUAD:LI22:301:BMAX")
  field(DOL4, "QUAD:LI22:301:BMIN")
  field(DOL5, "QUAD:LI22:301:BMIN")
  field(DOL6, "QUAD:LI22:301:BMIN")
  field(LNK1, "QUAD:LI22:301:BMAGX.HOPR")
  field(LNK2, "QUAD:LI22:301:BMAGY.HOPR")
  field(LNK3, "QUAD:LI22:301:BLEM.HOPR")
  field(LNK4, "QUAD:LI22:301:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI22:301:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI22:301:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:301:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:301:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI22:301:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI22:301:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI22:301:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:301:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:301:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:301:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:301:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:301:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI22:301:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI22:301:EDES NPP MS")
  field(INPB, "QUAD:LI22:301:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI22:401:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI22:401:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI22:401:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI22:401:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI22:401:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI22:401:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI22:401:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI22:401:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI22:401:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI22:401:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI22:401:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI22:401:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI22:401:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI22:401:EDES.PROC PP")
    field(LNK2, "QUAD:LI22:401:EACT.PROC PP")
    field(LNK3, "QUAD:LI22:401:EERR.DISA PP")
    field(LNK4, "QUAD:LI22:401:ECON.PROC PP")
    field(LNK5, "QUAD:LI22:401:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI22:401:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI22:401:BLEM.PROC PP")
    field(LNK8, "QUAD:LI22:401:BMOD.PROC PP")
    field(LNK9, "QUAD:LI22:401:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI22:401:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI22:401:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI22:401:BMAX")
  field(DOL2, "QUAD:LI22:401:BMAX")
  field(DOL3, "QUAD:LI22:401:BMAX")
  field(DOL4, "QUAD:LI22:401:BMIN")
  field(DOL5, "QUAD:LI22:401:BMIN")
  field(DOL6, "QUAD:LI22:401:BMIN")
  field(LNK1, "QUAD:LI22:401:BMAGX.HOPR")
  field(LNK2, "QUAD:LI22:401:BMAGY.HOPR")
  field(LNK3, "QUAD:LI22:401:BLEM.HOPR")
  field(LNK4, "QUAD:LI22:401:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI22:401:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI22:401:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:401:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:401:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI22:401:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI22:401:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI22:401:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:401:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:401:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:401:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:401:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:401:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI22:401:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI22:401:EDES NPP MS")
  field(INPB, "QUAD:LI22:401:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI22:501:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI22:501:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI22:501:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI22:501:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI22:501:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI22:501:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI22:501:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI22:501:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI22:501:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI22:501:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI22:501:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI22:501:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI22:501:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI22:501:EDES.PROC PP")
    field(LNK2, "QUAD:LI22:501:EACT.PROC PP")
    field(LNK3, "QUAD:LI22:501:EERR.DISA PP")
    field(LNK4, "QUAD:LI22:501:ECON.PROC PP")
    field(LNK5, "QUAD:LI22:501:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI22:501:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI22:501:BLEM.PROC PP")
    field(LNK8, "QUAD:LI22:501:BMOD.PROC PP")
    field(LNK9, "QUAD:LI22:501:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI22:501:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI22:501:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI22:501:BMAX")
  field(DOL2, "QUAD:LI22:501:BMAX")
  field(DOL3, "QUAD:LI22:501:BMAX")
  field(DOL4, "QUAD:LI22:501:BMIN")
  field(DOL5, "QUAD:LI22:501:BMIN")
  field(DOL6, "QUAD:LI22:501:BMIN")
  field(LNK1, "QUAD:LI22:501:BMAGX.HOPR")
  field(LNK2, "QUAD:LI22:501:BMAGY.HOPR")
  field(LNK3, "QUAD:LI22:501:BLEM.HOPR")
  field(LNK4, "QUAD:LI22:501:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI22:501:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI22:501:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:501:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:501:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI22:501:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI22:501:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI22:501:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:501:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:501:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:501:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:501:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:501:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI22:501:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI22:501:EDES NPP MS")
  field(INPB, "QUAD:LI22:501:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI22:601:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI22:601:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI22:601:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI22:601:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI22:601:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI22:601:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI22:601:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI22:601:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI22:601:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI22:601:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI22:601:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI22:601:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI22:601:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI22:601:EDES.PROC PP")
    field(LNK2, "QUAD:LI22:601:EACT.PROC PP")
    field(LNK3, "QUAD:LI22:601:EERR.DISA PP")
    field(LNK4, "QUAD:LI22:601:ECON.PROC PP")
    field(LNK5, "QUAD:LI22:601:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI22:601:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI22:601:BLEM.PROC PP")
    field(LNK8, "QUAD:LI22:601:BMOD.PROC PP")
    field(LNK9, "QUAD:LI22:601:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI22:601:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI22:601:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI22:601:BMAX")
  field(DOL2, "QUAD:LI22:601:BMAX")
  field(DOL3, "QUAD:LI22:601:BMAX")
  field(DOL4, "QUAD:LI22:601:BMIN")
  field(DOL5, "QUAD:LI22:601:BMIN")
  field(DOL6, "QUAD:LI22:601:BMIN")
  field(LNK1, "QUAD:LI22:601:BMAGX.HOPR")
  field(LNK2, "QUAD:LI22:601:BMAGY.HOPR")
  field(LNK3, "QUAD:LI22:601:BLEM.HOPR")
  field(LNK4, "QUAD:LI22:601:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI22:601:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI22:601:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:601:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:601:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI22:601:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI22:601:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI22:601:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:601:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:601:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:601:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:601:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:601:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI22:601:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI22:601:EDES NPP MS")
  field(INPB, "QUAD:LI22:601:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI22:701:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI22:701:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI22:701:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI22:701:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI22:701:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI22:701:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI22:701:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI22:701:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI22:701:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI22:701:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI22:701:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI22:701:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI22:701:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI22:701:EDES.PROC PP")
    field(LNK2, "QUAD:LI22:701:EACT.PROC PP")
    field(LNK3, "QUAD:LI22:701:EERR.DISA PP")
    field(LNK4, "QUAD:LI22:701:ECON.PROC PP")
    field(LNK5, "QUAD:LI22:701:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI22:701:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI22:701:BLEM.PROC PP")
    field(LNK8, "QUAD:LI22:701:BMOD.PROC PP")
    field(LNK9, "QUAD:LI22:701:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI22:701:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI22:701:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI22:701:BMAX")
  field(DOL2, "QUAD:LI22:701:BMAX")
  field(DOL3, "QUAD:LI22:701:BMAX")
  field(DOL4, "QUAD:LI22:701:BMIN")
  field(DOL5, "QUAD:LI22:701:BMIN")
  field(DOL6, "QUAD:LI22:701:BMIN")
  field(LNK1, "QUAD:LI22:701:BMAGX.HOPR")
  field(LNK2, "QUAD:LI22:701:BMAGY.HOPR")
  field(LNK3, "QUAD:LI22:701:BLEM.HOPR")
  field(LNK4, "QUAD:LI22:701:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI22:701:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI22:701:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:701:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:701:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI22:701:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI22:701:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI22:701:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:701:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:701:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:701:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:701:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:701:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI22:701:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI22:701:EDES NPP MS")
  field(INPB, "QUAD:LI22:701:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI22:801:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI22:801:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI22:801:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI22:801:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI22:801:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI22:801:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI22:801:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI22:801:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI22:801:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI22:801:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI22:801:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI22:801:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI22:801:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI22:801:EDES.PROC PP")
    field(LNK2, "QUAD:LI22:801:EACT.PROC PP")
    field(LNK3, "QUAD:LI22:801:EERR.DISA PP")
    field(LNK4, "QUAD:LI22:801:ECON.PROC PP")
    field(LNK5, "QUAD:LI22:801:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI22:801:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI22:801:BLEM.PROC PP")
    field(LNK8, "QUAD:LI22:801:BMOD.PROC PP")
    field(LNK9, "QUAD:LI22:801:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI22:801:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI22:801:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI22:801:BMAX")
  field(DOL2, "QUAD:LI22:801:BMAX")
  field(DOL3, "QUAD:LI22:801:BMAX")
  field(DOL4, "QUAD:LI22:801:BMIN")
  field(DOL5, "QUAD:LI22:801:BMIN")
  field(DOL6, "QUAD:LI22:801:BMIN")
  field(LNK1, "QUAD:LI22:801:BMAGX.HOPR")
  field(LNK2, "QUAD:LI22:801:BMAGY.HOPR")
  field(LNK3, "QUAD:LI22:801:BLEM.HOPR")
  field(LNK4, "QUAD:LI22:801:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI22:801:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI22:801:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:801:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:801:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI22:801:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI22:801:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI22:801:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:801:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:801:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:801:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:801:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:801:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI22:801:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI22:801:EDES NPP MS")
  field(INPB, "QUAD:LI22:801:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI22:901:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI22:901:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI22:901:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI22:901:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI22:901:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI22:901:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI22:901:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI22:901:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI22:901:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI22:901:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI22:901:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI22:901:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI22:901:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI22:901:EDES.PROC PP")
    field(LNK2, "QUAD:LI22:901:EACT.PROC PP")
    field(LNK3, "QUAD:LI22:901:EERR.DISA PP")
    field(LNK4, "QUAD:LI22:901:ECON.PROC PP")
    field(LNK5, "QUAD:LI22:901:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI22:901:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI22:901:BLEM.PROC PP")
    field(LNK8, "QUAD:LI22:901:BMOD.PROC PP")
    field(LNK9, "QUAD:LI22:901:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI22:901:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI22:901:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI22:901:BMAX")
  field(DOL2, "QUAD:LI22:901:BMAX")
  field(DOL3, "QUAD:LI22:901:BMAX")
  field(DOL4, "QUAD:LI22:901:BMIN")
  field(DOL5, "QUAD:LI22:901:BMIN")
  field(DOL6, "QUAD:LI22:901:BMIN")
  field(LNK1, "QUAD:LI22:901:BMAGX.HOPR")
  field(LNK2, "QUAD:LI22:901:BMAGY.HOPR")
  field(LNK3, "QUAD:LI22:901:BLEM.HOPR")
  field(LNK4, "QUAD:LI22:901:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI22:901:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI22:901:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:901:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI22:901:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI22:901:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI22:901:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI22:901:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:901:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:901:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:901:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI22:901:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI22:901:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI22:901:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI22:901:EDES NPP MS")
  field(INPB, "QUAD:LI22:901:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI22:202:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI22:202:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI22:202:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI22:202:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI22:202:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI22:202:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI22:202:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI22:202:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI22:202:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI22:202:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI22:202:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI22:202:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI22:202:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI22:202:EDES.PROC PP")
    field(LNK2, "XCOR:LI22:202:EACT.PROC PP")
    field(LNK3, "XCOR:LI22:202:EERR.DISA PP")
    field(LNK4, "XCOR:LI22:202:ECON.PROC PP")
    field(LNK5, "XCOR:LI22:202:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI22:202:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI22:202:BLEM.PROC PP")
    field(LNK8, "XCOR:LI22:202:BMOD.PROC PP")
    field(LNK9, "XCOR:LI22:202:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI22:202:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI22:202:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI22:202:BMAX")
  field(DOL2, "XCOR:LI22:202:BMAX")
  field(DOL3, "XCOR:LI22:202:BMAX")
  field(DOL4, "XCOR:LI22:202:BMIN")
  field(DOL5, "XCOR:LI22:202:BMIN")
  field(DOL6, "XCOR:LI22:202:BMIN")
  field(LNK1, "XCOR:LI22:202:BMAGX.HOPR")
  field(LNK2, "XCOR:LI22:202:BMAGY.HOPR")
  field(LNK3, "XCOR:LI22:202:BLEM.HOPR")
  field(LNK4, "XCOR:LI22:202:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI22:202:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI22:202:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:202:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:202:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI22:202:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI22:202:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI22:202:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:202:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:202:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:202:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:202:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:202:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI22:202:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI22:202:EDES NPP MS")
  field(INPB, "XCOR:LI22:202:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI22:302:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI22:302:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI22:302:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI22:302:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI22:302:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI22:302:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI22:302:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI22:302:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI22:302:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI22:302:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI22:302:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI22:302:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI22:302:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI22:302:EDES.PROC PP")
    field(LNK2, "XCOR:LI22:302:EACT.PROC PP")
    field(LNK3, "XCOR:LI22:302:EERR.DISA PP")
    field(LNK4, "XCOR:LI22:302:ECON.PROC PP")
    field(LNK5, "XCOR:LI22:302:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI22:302:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI22:302:BLEM.PROC PP")
    field(LNK8, "XCOR:LI22:302:BMOD.PROC PP")
    field(LNK9, "XCOR:LI22:302:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI22:302:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI22:302:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI22:302:BMAX")
  field(DOL2, "XCOR:LI22:302:BMAX")
  field(DOL3, "XCOR:LI22:302:BMAX")
  field(DOL4, "XCOR:LI22:302:BMIN")
  field(DOL5, "XCOR:LI22:302:BMIN")
  field(DOL6, "XCOR:LI22:302:BMIN")
  field(LNK1, "XCOR:LI22:302:BMAGX.HOPR")
  field(LNK2, "XCOR:LI22:302:BMAGY.HOPR")
  field(LNK3, "XCOR:LI22:302:BLEM.HOPR")
  field(LNK4, "XCOR:LI22:302:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI22:302:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI22:302:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:302:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:302:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI22:302:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI22:302:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI22:302:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:302:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:302:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:302:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:302:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:302:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI22:302:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI22:302:EDES NPP MS")
  field(INPB, "XCOR:LI22:302:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI22:402:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI22:402:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI22:402:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI22:402:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI22:402:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI22:402:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI22:402:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI22:402:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI22:402:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI22:402:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI22:402:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI22:402:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI22:402:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI22:402:EDES.PROC PP")
    field(LNK2, "XCOR:LI22:402:EACT.PROC PP")
    field(LNK3, "XCOR:LI22:402:EERR.DISA PP")
    field(LNK4, "XCOR:LI22:402:ECON.PROC PP")
    field(LNK5, "XCOR:LI22:402:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI22:402:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI22:402:BLEM.PROC PP")
    field(LNK8, "XCOR:LI22:402:BMOD.PROC PP")
    field(LNK9, "XCOR:LI22:402:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI22:402:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI22:402:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI22:402:BMAX")
  field(DOL2, "XCOR:LI22:402:BMAX")
  field(DOL3, "XCOR:LI22:402:BMAX")
  field(DOL4, "XCOR:LI22:402:BMIN")
  field(DOL5, "XCOR:LI22:402:BMIN")
  field(DOL6, "XCOR:LI22:402:BMIN")
  field(LNK1, "XCOR:LI22:402:BMAGX.HOPR")
  field(LNK2, "XCOR:LI22:402:BMAGY.HOPR")
  field(LNK3, "XCOR:LI22:402:BLEM.HOPR")
  field(LNK4, "XCOR:LI22:402:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI22:402:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI22:402:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:402:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:402:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI22:402:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI22:402:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI22:402:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:402:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:402:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:402:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:402:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:402:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI22:402:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI22:402:EDES NPP MS")
  field(INPB, "XCOR:LI22:402:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI22:502:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI22:502:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI22:502:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI22:502:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI22:502:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI22:502:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI22:502:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI22:502:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI22:502:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI22:502:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI22:502:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI22:502:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI22:502:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI22:502:EDES.PROC PP")
    field(LNK2, "XCOR:LI22:502:EACT.PROC PP")
    field(LNK3, "XCOR:LI22:502:EERR.DISA PP")
    field(LNK4, "XCOR:LI22:502:ECON.PROC PP")
    field(LNK5, "XCOR:LI22:502:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI22:502:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI22:502:BLEM.PROC PP")
    field(LNK8, "XCOR:LI22:502:BMOD.PROC PP")
    field(LNK9, "XCOR:LI22:502:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI22:502:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI22:502:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI22:502:BMAX")
  field(DOL2, "XCOR:LI22:502:BMAX")
  field(DOL3, "XCOR:LI22:502:BMAX")
  field(DOL4, "XCOR:LI22:502:BMIN")
  field(DOL5, "XCOR:LI22:502:BMIN")
  field(DOL6, "XCOR:LI22:502:BMIN")
  field(LNK1, "XCOR:LI22:502:BMAGX.HOPR")
  field(LNK2, "XCOR:LI22:502:BMAGY.HOPR")
  field(LNK3, "XCOR:LI22:502:BLEM.HOPR")
  field(LNK4, "XCOR:LI22:502:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI22:502:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI22:502:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:502:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:502:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI22:502:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI22:502:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI22:502:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:502:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:502:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:502:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:502:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:502:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI22:502:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI22:502:EDES NPP MS")
  field(INPB, "XCOR:LI22:502:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI22:602:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI22:602:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI22:602:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI22:602:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI22:602:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI22:602:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI22:602:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI22:602:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI22:602:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI22:602:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI22:602:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI22:602:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI22:602:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI22:602:EDES.PROC PP")
    field(LNK2, "XCOR:LI22:602:EACT.PROC PP")
    field(LNK3, "XCOR:LI22:602:EERR.DISA PP")
    field(LNK4, "XCOR:LI22:602:ECON.PROC PP")
    field(LNK5, "XCOR:LI22:602:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI22:602:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI22:602:BLEM.PROC PP")
    field(LNK8, "XCOR:LI22:602:BMOD.PROC PP")
    field(LNK9, "XCOR:LI22:602:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI22:602:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI22:602:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI22:602:BMAX")
  field(DOL2, "XCOR:LI22:602:BMAX")
  field(DOL3, "XCOR:LI22:602:BMAX")
  field(DOL4, "XCOR:LI22:602:BMIN")
  field(DOL5, "XCOR:LI22:602:BMIN")
  field(DOL6, "XCOR:LI22:602:BMIN")
  field(LNK1, "XCOR:LI22:602:BMAGX.HOPR")
  field(LNK2, "XCOR:LI22:602:BMAGY.HOPR")
  field(LNK3, "XCOR:LI22:602:BLEM.HOPR")
  field(LNK4, "XCOR:LI22:602:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI22:602:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI22:602:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:602:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:602:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI22:602:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI22:602:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI22:602:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:602:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:602:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:602:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:602:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:602:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI22:602:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI22:602:EDES NPP MS")
  field(INPB, "XCOR:LI22:602:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI22:702:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI22:702:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI22:702:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI22:702:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI22:702:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI22:702:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI22:702:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI22:702:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI22:702:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI22:702:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI22:702:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI22:702:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI22:702:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI22:702:EDES.PROC PP")
    field(LNK2, "XCOR:LI22:702:EACT.PROC PP")
    field(LNK3, "XCOR:LI22:702:EERR.DISA PP")
    field(LNK4, "XCOR:LI22:702:ECON.PROC PP")
    field(LNK5, "XCOR:LI22:702:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI22:702:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI22:702:BLEM.PROC PP")
    field(LNK8, "XCOR:LI22:702:BMOD.PROC PP")
    field(LNK9, "XCOR:LI22:702:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI22:702:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI22:702:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI22:702:BMAX")
  field(DOL2, "XCOR:LI22:702:BMAX")
  field(DOL3, "XCOR:LI22:702:BMAX")
  field(DOL4, "XCOR:LI22:702:BMIN")
  field(DOL5, "XCOR:LI22:702:BMIN")
  field(DOL6, "XCOR:LI22:702:BMIN")
  field(LNK1, "XCOR:LI22:702:BMAGX.HOPR")
  field(LNK2, "XCOR:LI22:702:BMAGY.HOPR")
  field(LNK3, "XCOR:LI22:702:BLEM.HOPR")
  field(LNK4, "XCOR:LI22:702:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI22:702:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI22:702:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:702:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:702:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI22:702:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI22:702:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI22:702:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:702:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:702:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:702:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:702:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:702:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI22:702:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI22:702:EDES NPP MS")
  field(INPB, "XCOR:LI22:702:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI22:802:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI22:802:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI22:802:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI22:802:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI22:802:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI22:802:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI22:802:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI22:802:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI22:802:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI22:802:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI22:802:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI22:802:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI22:802:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI22:802:EDES.PROC PP")
    field(LNK2, "XCOR:LI22:802:EACT.PROC PP")
    field(LNK3, "XCOR:LI22:802:EERR.DISA PP")
    field(LNK4, "XCOR:LI22:802:ECON.PROC PP")
    field(LNK5, "XCOR:LI22:802:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI22:802:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI22:802:BLEM.PROC PP")
    field(LNK8, "XCOR:LI22:802:BMOD.PROC PP")
    field(LNK9, "XCOR:LI22:802:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI22:802:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI22:802:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI22:802:BMAX")
  field(DOL2, "XCOR:LI22:802:BMAX")
  field(DOL3, "XCOR:LI22:802:BMAX")
  field(DOL4, "XCOR:LI22:802:BMIN")
  field(DOL5, "XCOR:LI22:802:BMIN")
  field(DOL6, "XCOR:LI22:802:BMIN")
  field(LNK1, "XCOR:LI22:802:BMAGX.HOPR")
  field(LNK2, "XCOR:LI22:802:BMAGY.HOPR")
  field(LNK3, "XCOR:LI22:802:BLEM.HOPR")
  field(LNK4, "XCOR:LI22:802:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI22:802:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI22:802:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:802:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:802:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI22:802:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI22:802:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI22:802:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:802:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:802:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:802:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:802:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:802:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI22:802:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI22:802:EDES NPP MS")
  field(INPB, "XCOR:LI22:802:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI22:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI22:900:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI22:900:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI22:900:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI22:900:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI22:900:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI22:900:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI22:900:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI22:900:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI22:900:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI22:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI22:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI22:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI22:900:EDES.PROC PP")
    field(LNK2, "XCOR:LI22:900:EACT.PROC PP")
    field(LNK3, "XCOR:LI22:900:EERR.DISA PP")
    field(LNK4, "XCOR:LI22:900:ECON.PROC PP")
    field(LNK5, "XCOR:LI22:900:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI22:900:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI22:900:BLEM.PROC PP")
    field(LNK8, "XCOR:LI22:900:BMOD.PROC PP")
    field(LNK9, "XCOR:LI22:900:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI22:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI22:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI22:900:BMAX")
  field(DOL2, "XCOR:LI22:900:BMAX")
  field(DOL3, "XCOR:LI22:900:BMAX")
  field(DOL4, "XCOR:LI22:900:BMIN")
  field(DOL5, "XCOR:LI22:900:BMIN")
  field(DOL6, "XCOR:LI22:900:BMIN")
  field(LNK1, "XCOR:LI22:900:BMAGX.HOPR")
  field(LNK2, "XCOR:LI22:900:BMAGY.HOPR")
  field(LNK3, "XCOR:LI22:900:BLEM.HOPR")
  field(LNK4, "XCOR:LI22:900:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI22:900:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI22:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI22:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI22:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI22:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI22:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI22:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI22:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI22:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI22:900:EDES NPP MS")
  field(INPB, "XCOR:LI22:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI22:203:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI22:203:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI22:203:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI22:203:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI22:203:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI22:203:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI22:203:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI22:203:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI22:203:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI22:203:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI22:203:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI22:203:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI22:203:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI22:203:EDES.PROC PP")
    field(LNK2, "YCOR:LI22:203:EACT.PROC PP")
    field(LNK3, "YCOR:LI22:203:EERR.DISA PP")
    field(LNK4, "YCOR:LI22:203:ECON.PROC PP")
    field(LNK5, "YCOR:LI22:203:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI22:203:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI22:203:BLEM.PROC PP")
    field(LNK8, "YCOR:LI22:203:BMOD.PROC PP")
    field(LNK9, "YCOR:LI22:203:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI22:203:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI22:203:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI22:203:BMAX")
  field(DOL2, "YCOR:LI22:203:BMAX")
  field(DOL3, "YCOR:LI22:203:BMAX")
  field(DOL4, "YCOR:LI22:203:BMIN")
  field(DOL5, "YCOR:LI22:203:BMIN")
  field(DOL6, "YCOR:LI22:203:BMIN")
  field(LNK1, "YCOR:LI22:203:BMAGX.HOPR")
  field(LNK2, "YCOR:LI22:203:BMAGY.HOPR")
  field(LNK3, "YCOR:LI22:203:BLEM.HOPR")
  field(LNK4, "YCOR:LI22:203:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI22:203:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI22:203:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:203:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:203:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI22:203:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI22:203:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI22:203:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:203:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:203:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:203:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:203:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:203:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI22:203:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI22:203:EDES NPP MS")
  field(INPB, "YCOR:LI22:203:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI22:303:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI22:303:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI22:303:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI22:303:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI22:303:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI22:303:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI22:303:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI22:303:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI22:303:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI22:303:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI22:303:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI22:303:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI22:303:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI22:303:EDES.PROC PP")
    field(LNK2, "YCOR:LI22:303:EACT.PROC PP")
    field(LNK3, "YCOR:LI22:303:EERR.DISA PP")
    field(LNK4, "YCOR:LI22:303:ECON.PROC PP")
    field(LNK5, "YCOR:LI22:303:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI22:303:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI22:303:BLEM.PROC PP")
    field(LNK8, "YCOR:LI22:303:BMOD.PROC PP")
    field(LNK9, "YCOR:LI22:303:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI22:303:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI22:303:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI22:303:BMAX")
  field(DOL2, "YCOR:LI22:303:BMAX")
  field(DOL3, "YCOR:LI22:303:BMAX")
  field(DOL4, "YCOR:LI22:303:BMIN")
  field(DOL5, "YCOR:LI22:303:BMIN")
  field(DOL6, "YCOR:LI22:303:BMIN")
  field(LNK1, "YCOR:LI22:303:BMAGX.HOPR")
  field(LNK2, "YCOR:LI22:303:BMAGY.HOPR")
  field(LNK3, "YCOR:LI22:303:BLEM.HOPR")
  field(LNK4, "YCOR:LI22:303:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI22:303:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI22:303:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:303:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:303:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI22:303:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI22:303:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI22:303:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:303:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:303:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:303:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:303:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:303:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI22:303:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI22:303:EDES NPP MS")
  field(INPB, "YCOR:LI22:303:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI22:403:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI22:403:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI22:403:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI22:403:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI22:403:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI22:403:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI22:403:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI22:403:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI22:403:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI22:403:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI22:403:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI22:403:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI22:403:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI22:403:EDES.PROC PP")
    field(LNK2, "YCOR:LI22:403:EACT.PROC PP")
    field(LNK3, "YCOR:LI22:403:EERR.DISA PP")
    field(LNK4, "YCOR:LI22:403:ECON.PROC PP")
    field(LNK5, "YCOR:LI22:403:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI22:403:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI22:403:BLEM.PROC PP")
    field(LNK8, "YCOR:LI22:403:BMOD.PROC PP")
    field(LNK9, "YCOR:LI22:403:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI22:403:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI22:403:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI22:403:BMAX")
  field(DOL2, "YCOR:LI22:403:BMAX")
  field(DOL3, "YCOR:LI22:403:BMAX")
  field(DOL4, "YCOR:LI22:403:BMIN")
  field(DOL5, "YCOR:LI22:403:BMIN")
  field(DOL6, "YCOR:LI22:403:BMIN")
  field(LNK1, "YCOR:LI22:403:BMAGX.HOPR")
  field(LNK2, "YCOR:LI22:403:BMAGY.HOPR")
  field(LNK3, "YCOR:LI22:403:BLEM.HOPR")
  field(LNK4, "YCOR:LI22:403:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI22:403:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI22:403:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:403:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:403:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI22:403:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI22:403:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI22:403:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:403:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:403:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:403:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:403:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:403:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI22:403:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI22:403:EDES NPP MS")
  field(INPB, "YCOR:LI22:403:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI22:503:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI22:503:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI22:503:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI22:503:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI22:503:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI22:503:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI22:503:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI22:503:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI22:503:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI22:503:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI22:503:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI22:503:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI22:503:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI22:503:EDES.PROC PP")
    field(LNK2, "YCOR:LI22:503:EACT.PROC PP")
    field(LNK3, "YCOR:LI22:503:EERR.DISA PP")
    field(LNK4, "YCOR:LI22:503:ECON.PROC PP")
    field(LNK5, "YCOR:LI22:503:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI22:503:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI22:503:BLEM.PROC PP")
    field(LNK8, "YCOR:LI22:503:BMOD.PROC PP")
    field(LNK9, "YCOR:LI22:503:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI22:503:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI22:503:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI22:503:BMAX")
  field(DOL2, "YCOR:LI22:503:BMAX")
  field(DOL3, "YCOR:LI22:503:BMAX")
  field(DOL4, "YCOR:LI22:503:BMIN")
  field(DOL5, "YCOR:LI22:503:BMIN")
  field(DOL6, "YCOR:LI22:503:BMIN")
  field(LNK1, "YCOR:LI22:503:BMAGX.HOPR")
  field(LNK2, "YCOR:LI22:503:BMAGY.HOPR")
  field(LNK3, "YCOR:LI22:503:BLEM.HOPR")
  field(LNK4, "YCOR:LI22:503:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI22:503:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI22:503:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:503:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:503:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI22:503:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI22:503:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI22:503:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:503:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:503:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:503:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:503:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:503:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI22:503:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI22:503:EDES NPP MS")
  field(INPB, "YCOR:LI22:503:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI22:603:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI22:603:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI22:603:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI22:603:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI22:603:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI22:603:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI22:603:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI22:603:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI22:603:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI22:603:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI22:603:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI22:603:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI22:603:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI22:603:EDES.PROC PP")
    field(LNK2, "YCOR:LI22:603:EACT.PROC PP")
    field(LNK3, "YCOR:LI22:603:EERR.DISA PP")
    field(LNK4, "YCOR:LI22:603:ECON.PROC PP")
    field(LNK5, "YCOR:LI22:603:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI22:603:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI22:603:BLEM.PROC PP")
    field(LNK8, "YCOR:LI22:603:BMOD.PROC PP")
    field(LNK9, "YCOR:LI22:603:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI22:603:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI22:603:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI22:603:BMAX")
  field(DOL2, "YCOR:LI22:603:BMAX")
  field(DOL3, "YCOR:LI22:603:BMAX")
  field(DOL4, "YCOR:LI22:603:BMIN")
  field(DOL5, "YCOR:LI22:603:BMIN")
  field(DOL6, "YCOR:LI22:603:BMIN")
  field(LNK1, "YCOR:LI22:603:BMAGX.HOPR")
  field(LNK2, "YCOR:LI22:603:BMAGY.HOPR")
  field(LNK3, "YCOR:LI22:603:BLEM.HOPR")
  field(LNK4, "YCOR:LI22:603:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI22:603:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI22:603:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:603:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:603:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI22:603:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI22:603:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI22:603:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:603:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:603:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:603:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:603:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:603:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI22:603:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI22:603:EDES NPP MS")
  field(INPB, "YCOR:LI22:603:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI22:703:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI22:703:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI22:703:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI22:703:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI22:703:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI22:703:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI22:703:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI22:703:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI22:703:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI22:703:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI22:703:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI22:703:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI22:703:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI22:703:EDES.PROC PP")
    field(LNK2, "YCOR:LI22:703:EACT.PROC PP")
    field(LNK3, "YCOR:LI22:703:EERR.DISA PP")
    field(LNK4, "YCOR:LI22:703:ECON.PROC PP")
    field(LNK5, "YCOR:LI22:703:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI22:703:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI22:703:BLEM.PROC PP")
    field(LNK8, "YCOR:LI22:703:BMOD.PROC PP")
    field(LNK9, "YCOR:LI22:703:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI22:703:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI22:703:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI22:703:BMAX")
  field(DOL2, "YCOR:LI22:703:BMAX")
  field(DOL3, "YCOR:LI22:703:BMAX")
  field(DOL4, "YCOR:LI22:703:BMIN")
  field(DOL5, "YCOR:LI22:703:BMIN")
  field(DOL6, "YCOR:LI22:703:BMIN")
  field(LNK1, "YCOR:LI22:703:BMAGX.HOPR")
  field(LNK2, "YCOR:LI22:703:BMAGY.HOPR")
  field(LNK3, "YCOR:LI22:703:BLEM.HOPR")
  field(LNK4, "YCOR:LI22:703:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI22:703:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI22:703:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:703:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:703:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI22:703:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI22:703:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI22:703:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:703:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:703:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:703:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:703:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:703:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI22:703:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI22:703:EDES NPP MS")
  field(INPB, "YCOR:LI22:703:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI22:803:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI22:803:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI22:803:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI22:803:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI22:803:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI22:803:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI22:803:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI22:803:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI22:803:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI22:803:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI22:803:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI22:803:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI22:803:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI22:803:EDES.PROC PP")
    field(LNK2, "YCOR:LI22:803:EACT.PROC PP")
    field(LNK3, "YCOR:LI22:803:EERR.DISA PP")
    field(LNK4, "YCOR:LI22:803:ECON.PROC PP")
    field(LNK5, "YCOR:LI22:803:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI22:803:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI22:803:BLEM.PROC PP")
    field(LNK8, "YCOR:LI22:803:BMOD.PROC PP")
    field(LNK9, "YCOR:LI22:803:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI22:803:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI22:803:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI22:803:BMAX")
  field(DOL2, "YCOR:LI22:803:BMAX")
  field(DOL3, "YCOR:LI22:803:BMAX")
  field(DOL4, "YCOR:LI22:803:BMIN")
  field(DOL5, "YCOR:LI22:803:BMIN")
  field(DOL6, "YCOR:LI22:803:BMIN")
  field(LNK1, "YCOR:LI22:803:BMAGX.HOPR")
  field(LNK2, "YCOR:LI22:803:BMAGY.HOPR")
  field(LNK3, "YCOR:LI22:803:BLEM.HOPR")
  field(LNK4, "YCOR:LI22:803:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI22:803:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI22:803:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:803:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:803:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI22:803:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI22:803:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI22:803:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:803:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:803:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:803:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:803:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:803:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI22:803:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI22:803:EDES NPP MS")
  field(INPB, "YCOR:LI22:803:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI22:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI22:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI22:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI22:900:FUNC CA PP")
  field(DOL2, "MGNT:LI22:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI22:900:FUNC CA PP")
  field(DOL3, "MGNT:LI22:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI22:900:FUNC CA PP")
  field(DOL4, "MGNT:LI22:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI22:900:FUNC CA PP")
  field(DOL5, "MGNT:LI22:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI22:900:FUNC CA PP")
  field(DOL6, "MGNT:LI22:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI22:900:FUNC CA PP")
  field(DOL7, "MGNT:LI22:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI22:900:FUNC CA PP")
  field(DOL8, "MGNT:LI22:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI22:900:FUNC CA PP")
  field(DOL9, "MGNT:LI22:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI22:900:FUNC CA PP")
  field(DOLA, "MGNT:LI22:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI22:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI22:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI22:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI22:900:EDES.PROC PP")
    field(LNK2, "YCOR:LI22:900:EACT.PROC PP")
    field(LNK3, "YCOR:LI22:900:EERR.DISA PP")
    field(LNK4, "YCOR:LI22:900:ECON.PROC PP")
    field(LNK5, "YCOR:LI22:900:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI22:900:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI22:900:BLEM.PROC PP")
    field(LNK8, "YCOR:LI22:900:BMOD.PROC PP")
    field(LNK9, "YCOR:LI22:900:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI22:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI22:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI22:900:BMAX")
  field(DOL2, "YCOR:LI22:900:BMAX")
  field(DOL3, "YCOR:LI22:900:BMAX")
  field(DOL4, "YCOR:LI22:900:BMIN")
  field(DOL5, "YCOR:LI22:900:BMIN")
  field(DOL6, "YCOR:LI22:900:BMIN")
  field(LNK1, "YCOR:LI22:900:BMAGX.HOPR")
  field(LNK2, "YCOR:LI22:900:BMAGY.HOPR")
  field(LNK3, "YCOR:LI22:900:BLEM.HOPR")
  field(LNK4, "YCOR:LI22:900:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI22:900:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI22:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI22:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI22:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI22:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI22:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI22:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI22:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI22:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI22:900:EDES NPP MS")
  field(INPB, "YCOR:LI22:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LI24:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "LGPS:LI24:2:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LI24:2:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LI24:2:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LI24:2:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LI24:2:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LI24:2:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LI24:2:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LI24:2:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LI24:2:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LI24:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LI24:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LI24:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LI24:2:EDES.PROC PP")
    field(LNK2, "LGPS:LI24:2:EACT.PROC PP")
    field(LNK3, "LGPS:LI24:2:EERR.DISA PP")
    field(LNK4, "LGPS:LI24:2:ECON.PROC PP")
    field(LNK5, "LGPS:LI24:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:LI24:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:LI24:2:BLEM.PROC PP")
    field(LNK8, "LGPS:LI24:2:BMOD.PROC PP")
    field(LNK9, "LGPS:LI24:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LI24:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LI24:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LI24:2:BMAX")
  field(DOL2, "LGPS:LI24:2:BMAX")
  field(DOL3, "LGPS:LI24:2:BMAX")
  field(DOL4, "LGPS:LI24:2:BMIN")
  field(DOL5, "LGPS:LI24:2:BMIN")
  field(DOL6, "LGPS:LI24:2:BMIN")
  field(LNK1, "LGPS:LI24:2:BMAGX.HOPR")
  field(LNK2, "LGPS:LI24:2:BMAGY.HOPR")
  field(LNK3, "LGPS:LI24:2:BLEM.HOPR")
  field(LNK4, "LGPS:LI24:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LI24:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LI24:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LI24:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LI24:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LI24:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LI24:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LI24:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI24:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI24:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI24:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI24:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI24:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LI24:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LI24:2:EDES NPP MS")
  field(INPB, "LGPS:LI24:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LI24:3:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "LGPS:LI24:3:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LI24:3:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LI24:3:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LI24:3:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LI24:3:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LI24:3:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LI24:3:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LI24:3:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LI24:3:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LI24:3:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LI24:3:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LI24:3:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LI24:3:EDES.PROC PP")
    field(LNK2, "LGPS:LI24:3:EACT.PROC PP")
    field(LNK3, "LGPS:LI24:3:EERR.DISA PP")
    field(LNK4, "LGPS:LI24:3:ECON.PROC PP")
    field(LNK5, "LGPS:LI24:3:BMAGX.PROC PP")
    field(LNK6, "LGPS:LI24:3:BMAGY.PROC PP")
    field(LNK7, "LGPS:LI24:3:BLEM.PROC PP")
    field(LNK8, "LGPS:LI24:3:BMOD.PROC PP")
    field(LNK9, "LGPS:LI24:3:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LI24:3:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LI24:3:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LI24:3:BMAX")
  field(DOL2, "LGPS:LI24:3:BMAX")
  field(DOL3, "LGPS:LI24:3:BMAX")
  field(DOL4, "LGPS:LI24:3:BMIN")
  field(DOL5, "LGPS:LI24:3:BMIN")
  field(DOL6, "LGPS:LI24:3:BMIN")
  field(LNK1, "LGPS:LI24:3:BMAGX.HOPR")
  field(LNK2, "LGPS:LI24:3:BMAGY.HOPR")
  field(LNK3, "LGPS:LI24:3:BLEM.HOPR")
  field(LNK4, "LGPS:LI24:3:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LI24:3:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LI24:3:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LI24:3:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LI24:3:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LI24:3:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LI24:3:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LI24:3:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI24:3:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI24:3:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI24:3:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI24:3:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI24:3:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LI24:3:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LI24:3:EDES NPP MS")
  field(INPB, "LGPS:LI24:3:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LI24:790:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "BEND:LI24:790:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LI24:790:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LI24:790:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LI24:790:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LI24:790:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LI24:790:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LI24:790:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LI24:790:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LI24:790:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LI24:790:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LI24:790:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LI24:790:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LI24:790:EDES.PROC PP")
    field(LNK2, "BEND:LI24:790:EACT.PROC PP")
    field(LNK3, "BEND:LI24:790:EERR.DISA PP")
    field(LNK4, "BEND:LI24:790:ECON.PROC PP")
    field(LNK5, "BEND:LI24:790:BMAGX.PROC PP")
    field(LNK6, "BEND:LI24:790:BMAGY.PROC PP")
    field(LNK7, "BEND:LI24:790:BLEM.PROC PP")
    field(LNK8, "BEND:LI24:790:BMOD.PROC PP")
    field(LNK9, "BEND:LI24:790:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LI24:790:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LI24:790:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LI24:790:BMAX")
  field(DOL2, "BEND:LI24:790:BMAX")
  field(DOL3, "BEND:LI24:790:BMAX")
  field(DOL4, "BEND:LI24:790:BMIN")
  field(DOL5, "BEND:LI24:790:BMIN")
  field(DOL6, "BEND:LI24:790:BMIN")
  field(LNK1, "BEND:LI24:790:BMAGX.HOPR")
  field(LNK2, "BEND:LI24:790:BMAGY.HOPR")
  field(LNK3, "BEND:LI24:790:BLEM.HOPR")
  field(LNK4, "BEND:LI24:790:BMAGX.LOPR PP")
  field(LNK5, "BEND:LI24:790:BMAGY.LOPR PP")
  field(LNK6, "BEND:LI24:790:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LI24:790:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LI24:790:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LI24:790:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LI24:790:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LI24:790:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI24:790:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI24:790:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LI24:790:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI24:790:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LI24:790:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LI24:790:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LI24:790:EDES NPP MS")
  field(INPB, "BEND:LI24:790:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LI24:720:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "BTRM:LI24:720:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LI24:720:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LI24:720:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LI24:720:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LI24:720:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LI24:720:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LI24:720:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LI24:720:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LI24:720:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LI24:720:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LI24:720:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LI24:720:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LI24:720:EDES.PROC PP")
    field(LNK2, "BTRM:LI24:720:EACT.PROC PP")
    field(LNK3, "BTRM:LI24:720:EERR.DISA PP")
    field(LNK4, "BTRM:LI24:720:ECON.PROC PP")
    field(LNK5, "BTRM:LI24:720:BMAGX.PROC PP")
    field(LNK6, "BTRM:LI24:720:BMAGY.PROC PP")
    field(LNK7, "BTRM:LI24:720:BLEM.PROC PP")
    field(LNK8, "BTRM:LI24:720:BMOD.PROC PP")
    field(LNK9, "BTRM:LI24:720:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LI24:720:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LI24:720:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LI24:720:BMAX")
  field(DOL2, "BTRM:LI24:720:BMAX")
  field(DOL3, "BTRM:LI24:720:BMAX")
  field(DOL4, "BTRM:LI24:720:BMIN")
  field(DOL5, "BTRM:LI24:720:BMIN")
  field(DOL6, "BTRM:LI24:720:BMIN")
  field(LNK1, "BTRM:LI24:720:BMAGX.HOPR")
  field(LNK2, "BTRM:LI24:720:BMAGY.HOPR")
  field(LNK3, "BTRM:LI24:720:BLEM.HOPR")
  field(LNK4, "BTRM:LI24:720:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LI24:720:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LI24:720:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LI24:720:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LI24:720:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LI24:720:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LI24:720:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LI24:720:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI24:720:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI24:720:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LI24:720:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI24:720:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LI24:720:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LI24:720:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LI24:720:EDES NPP MS")
  field(INPB, "BTRM:LI24:720:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LI24:810:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "BTRM:LI24:810:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LI24:810:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LI24:810:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LI24:810:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LI24:810:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LI24:810:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LI24:810:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LI24:810:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LI24:810:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LI24:810:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LI24:810:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LI24:810:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LI24:810:EDES.PROC PP")
    field(LNK2, "BTRM:LI24:810:EACT.PROC PP")
    field(LNK3, "BTRM:LI24:810:EERR.DISA PP")
    field(LNK4, "BTRM:LI24:810:ECON.PROC PP")
    field(LNK5, "BTRM:LI24:810:BMAGX.PROC PP")
    field(LNK6, "BTRM:LI24:810:BMAGY.PROC PP")
    field(LNK7, "BTRM:LI24:810:BLEM.PROC PP")
    field(LNK8, "BTRM:LI24:810:BMOD.PROC PP")
    field(LNK9, "BTRM:LI24:810:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LI24:810:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LI24:810:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LI24:810:BMAX")
  field(DOL2, "BTRM:LI24:810:BMAX")
  field(DOL3, "BTRM:LI24:810:BMAX")
  field(DOL4, "BTRM:LI24:810:BMIN")
  field(DOL5, "BTRM:LI24:810:BMIN")
  field(DOL6, "BTRM:LI24:810:BMIN")
  field(LNK1, "BTRM:LI24:810:BMAGX.HOPR")
  field(LNK2, "BTRM:LI24:810:BMAGY.HOPR")
  field(LNK3, "BTRM:LI24:810:BLEM.HOPR")
  field(LNK4, "BTRM:LI24:810:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LI24:810:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LI24:810:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LI24:810:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LI24:810:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LI24:810:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LI24:810:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LI24:810:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI24:810:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI24:810:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LI24:810:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI24:810:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LI24:810:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LI24:810:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LI24:810:EDES NPP MS")
  field(INPB, "BTRM:LI24:810:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LI24:880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "BTRM:LI24:880:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LI24:880:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LI24:880:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LI24:880:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LI24:880:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LI24:880:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LI24:880:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LI24:880:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LI24:880:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LI24:880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LI24:880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LI24:880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LI24:880:EDES.PROC PP")
    field(LNK2, "BTRM:LI24:880:EACT.PROC PP")
    field(LNK3, "BTRM:LI24:880:EERR.DISA PP")
    field(LNK4, "BTRM:LI24:880:ECON.PROC PP")
    field(LNK5, "BTRM:LI24:880:BMAGX.PROC PP")
    field(LNK6, "BTRM:LI24:880:BMAGY.PROC PP")
    field(LNK7, "BTRM:LI24:880:BLEM.PROC PP")
    field(LNK8, "BTRM:LI24:880:BMOD.PROC PP")
    field(LNK9, "BTRM:LI24:880:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LI24:880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LI24:880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LI24:880:BMAX")
  field(DOL2, "BTRM:LI24:880:BMAX")
  field(DOL3, "BTRM:LI24:880:BMAX")
  field(DOL4, "BTRM:LI24:880:BMIN")
  field(DOL5, "BTRM:LI24:880:BMIN")
  field(DOL6, "BTRM:LI24:880:BMIN")
  field(LNK1, "BTRM:LI24:880:BMAGX.HOPR")
  field(LNK2, "BTRM:LI24:880:BMAGY.HOPR")
  field(LNK3, "BTRM:LI24:880:BLEM.HOPR")
  field(LNK4, "BTRM:LI24:880:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LI24:880:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LI24:880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LI24:880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LI24:880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LI24:880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LI24:880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LI24:880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI24:880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI24:880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LI24:880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LI24:880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LI24:880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LI24:880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LI24:880:EDES NPP MS")
  field(INPB, "BTRM:LI24:880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI24:201:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI24:201:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI24:201:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI24:201:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI24:201:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI24:201:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI24:201:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI24:201:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI24:201:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI24:201:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI24:201:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI24:201:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI24:201:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI24:201:EDES.PROC PP")
    field(LNK2, "QUAD:LI24:201:EACT.PROC PP")
    field(LNK3, "QUAD:LI24:201:EERR.DISA PP")
    field(LNK4, "QUAD:LI24:201:ECON.PROC PP")
    field(LNK5, "QUAD:LI24:201:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI24:201:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI24:201:BLEM.PROC PP")
    field(LNK8, "QUAD:LI24:201:BMOD.PROC PP")
    field(LNK9, "QUAD:LI24:201:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI24:201:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI24:201:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI24:201:BMAX")
  field(DOL2, "QUAD:LI24:201:BMAX")
  field(DOL3, "QUAD:LI24:201:BMAX")
  field(DOL4, "QUAD:LI24:201:BMIN")
  field(DOL5, "QUAD:LI24:201:BMIN")
  field(DOL6, "QUAD:LI24:201:BMIN")
  field(LNK1, "QUAD:LI24:201:BMAGX.HOPR")
  field(LNK2, "QUAD:LI24:201:BMAGY.HOPR")
  field(LNK3, "QUAD:LI24:201:BLEM.HOPR")
  field(LNK4, "QUAD:LI24:201:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI24:201:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI24:201:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:201:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:201:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI24:201:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI24:201:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI24:201:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:201:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:201:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:201:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:201:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:201:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI24:201:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI24:201:EDES NPP MS")
  field(INPB, "QUAD:LI24:201:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI24:301:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI24:301:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI24:301:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI24:301:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI24:301:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI24:301:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI24:301:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI24:301:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI24:301:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI24:301:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI24:301:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI24:301:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI24:301:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI24:301:EDES.PROC PP")
    field(LNK2, "QUAD:LI24:301:EACT.PROC PP")
    field(LNK3, "QUAD:LI24:301:EERR.DISA PP")
    field(LNK4, "QUAD:LI24:301:ECON.PROC PP")
    field(LNK5, "QUAD:LI24:301:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI24:301:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI24:301:BLEM.PROC PP")
    field(LNK8, "QUAD:LI24:301:BMOD.PROC PP")
    field(LNK9, "QUAD:LI24:301:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI24:301:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI24:301:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI24:301:BMAX")
  field(DOL2, "QUAD:LI24:301:BMAX")
  field(DOL3, "QUAD:LI24:301:BMAX")
  field(DOL4, "QUAD:LI24:301:BMIN")
  field(DOL5, "QUAD:LI24:301:BMIN")
  field(DOL6, "QUAD:LI24:301:BMIN")
  field(LNK1, "QUAD:LI24:301:BMAGX.HOPR")
  field(LNK2, "QUAD:LI24:301:BMAGY.HOPR")
  field(LNK3, "QUAD:LI24:301:BLEM.HOPR")
  field(LNK4, "QUAD:LI24:301:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI24:301:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI24:301:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:301:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:301:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI24:301:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI24:301:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI24:301:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:301:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:301:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:301:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:301:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:301:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI24:301:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI24:301:EDES NPP MS")
  field(INPB, "QUAD:LI24:301:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI24:401:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI24:401:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI24:401:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI24:401:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI24:401:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI24:401:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI24:401:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI24:401:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI24:401:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI24:401:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI24:401:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI24:401:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI24:401:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI24:401:EDES.PROC PP")
    field(LNK2, "QUAD:LI24:401:EACT.PROC PP")
    field(LNK3, "QUAD:LI24:401:EERR.DISA PP")
    field(LNK4, "QUAD:LI24:401:ECON.PROC PP")
    field(LNK5, "QUAD:LI24:401:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI24:401:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI24:401:BLEM.PROC PP")
    field(LNK8, "QUAD:LI24:401:BMOD.PROC PP")
    field(LNK9, "QUAD:LI24:401:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI24:401:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI24:401:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI24:401:BMAX")
  field(DOL2, "QUAD:LI24:401:BMAX")
  field(DOL3, "QUAD:LI24:401:BMAX")
  field(DOL4, "QUAD:LI24:401:BMIN")
  field(DOL5, "QUAD:LI24:401:BMIN")
  field(DOL6, "QUAD:LI24:401:BMIN")
  field(LNK1, "QUAD:LI24:401:BMAGX.HOPR")
  field(LNK2, "QUAD:LI24:401:BMAGY.HOPR")
  field(LNK3, "QUAD:LI24:401:BLEM.HOPR")
  field(LNK4, "QUAD:LI24:401:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI24:401:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI24:401:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:401:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:401:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI24:401:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI24:401:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI24:401:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:401:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:401:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:401:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:401:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:401:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI24:401:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI24:401:EDES NPP MS")
  field(INPB, "QUAD:LI24:401:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI24:501:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI24:501:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI24:501:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI24:501:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI24:501:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI24:501:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI24:501:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI24:501:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI24:501:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI24:501:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI24:501:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI24:501:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI24:501:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI24:501:EDES.PROC PP")
    field(LNK2, "QUAD:LI24:501:EACT.PROC PP")
    field(LNK3, "QUAD:LI24:501:EERR.DISA PP")
    field(LNK4, "QUAD:LI24:501:ECON.PROC PP")
    field(LNK5, "QUAD:LI24:501:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI24:501:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI24:501:BLEM.PROC PP")
    field(LNK8, "QUAD:LI24:501:BMOD.PROC PP")
    field(LNK9, "QUAD:LI24:501:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI24:501:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI24:501:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI24:501:BMAX")
  field(DOL2, "QUAD:LI24:501:BMAX")
  field(DOL3, "QUAD:LI24:501:BMAX")
  field(DOL4, "QUAD:LI24:501:BMIN")
  field(DOL5, "QUAD:LI24:501:BMIN")
  field(DOL6, "QUAD:LI24:501:BMIN")
  field(LNK1, "QUAD:LI24:501:BMAGX.HOPR")
  field(LNK2, "QUAD:LI24:501:BMAGY.HOPR")
  field(LNK3, "QUAD:LI24:501:BLEM.HOPR")
  field(LNK4, "QUAD:LI24:501:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI24:501:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI24:501:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:501:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:501:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI24:501:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI24:501:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI24:501:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:501:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:501:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:501:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:501:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:501:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI24:501:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI24:501:EDES NPP MS")
  field(INPB, "QUAD:LI24:501:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI24:601:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI24:601:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI24:601:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI24:601:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI24:601:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI24:601:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI24:601:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI24:601:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI24:601:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI24:601:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI24:601:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI24:601:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI24:601:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI24:601:EDES.PROC PP")
    field(LNK2, "QUAD:LI24:601:EACT.PROC PP")
    field(LNK3, "QUAD:LI24:601:EERR.DISA PP")
    field(LNK4, "QUAD:LI24:601:ECON.PROC PP")
    field(LNK5, "QUAD:LI24:601:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI24:601:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI24:601:BLEM.PROC PP")
    field(LNK8, "QUAD:LI24:601:BMOD.PROC PP")
    field(LNK9, "QUAD:LI24:601:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI24:601:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI24:601:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI24:601:BMAX")
  field(DOL2, "QUAD:LI24:601:BMAX")
  field(DOL3, "QUAD:LI24:601:BMAX")
  field(DOL4, "QUAD:LI24:601:BMIN")
  field(DOL5, "QUAD:LI24:601:BMIN")
  field(DOL6, "QUAD:LI24:601:BMIN")
  field(LNK1, "QUAD:LI24:601:BMAGX.HOPR")
  field(LNK2, "QUAD:LI24:601:BMAGY.HOPR")
  field(LNK3, "QUAD:LI24:601:BLEM.HOPR")
  field(LNK4, "QUAD:LI24:601:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI24:601:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI24:601:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:601:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:601:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI24:601:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI24:601:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI24:601:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:601:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:601:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:601:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:601:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:601:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI24:601:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI24:601:EDES NPP MS")
  field(INPB, "QUAD:LI24:601:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI24:701:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI24:701:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI24:701:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI24:701:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI24:701:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI24:701:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI24:701:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI24:701:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI24:701:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI24:701:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI24:701:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI24:701:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI24:701:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI24:701:EDES.PROC PP")
    field(LNK2, "QUAD:LI24:701:EACT.PROC PP")
    field(LNK3, "QUAD:LI24:701:EERR.DISA PP")
    field(LNK4, "QUAD:LI24:701:ECON.PROC PP")
    field(LNK5, "QUAD:LI24:701:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI24:701:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI24:701:BLEM.PROC PP")
    field(LNK8, "QUAD:LI24:701:BMOD.PROC PP")
    field(LNK9, "QUAD:LI24:701:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI24:701:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI24:701:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI24:701:BMAX")
  field(DOL2, "QUAD:LI24:701:BMAX")
  field(DOL3, "QUAD:LI24:701:BMAX")
  field(DOL4, "QUAD:LI24:701:BMIN")
  field(DOL5, "QUAD:LI24:701:BMIN")
  field(DOL6, "QUAD:LI24:701:BMIN")
  field(LNK1, "QUAD:LI24:701:BMAGX.HOPR")
  field(LNK2, "QUAD:LI24:701:BMAGY.HOPR")
  field(LNK3, "QUAD:LI24:701:BLEM.HOPR")
  field(LNK4, "QUAD:LI24:701:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI24:701:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI24:701:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:701:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:701:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI24:701:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI24:701:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI24:701:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:701:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:701:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:701:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:701:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:701:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI24:701:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI24:701:EDES NPP MS")
  field(INPB, "QUAD:LI24:701:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI24:713:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI24:713:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI24:713:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI24:713:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI24:713:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI24:713:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI24:713:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI24:713:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI24:713:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI24:713:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI24:713:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI24:713:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI24:713:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI24:713:EDES.PROC PP")
    field(LNK2, "QUAD:LI24:713:EACT.PROC PP")
    field(LNK3, "QUAD:LI24:713:EERR.DISA PP")
    field(LNK4, "QUAD:LI24:713:ECON.PROC PP")
    field(LNK5, "QUAD:LI24:713:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI24:713:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI24:713:BLEM.PROC PP")
    field(LNK8, "QUAD:LI24:713:BMOD.PROC PP")
    field(LNK9, "QUAD:LI24:713:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI24:713:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI24:713:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI24:713:BMAX")
  field(DOL2, "QUAD:LI24:713:BMAX")
  field(DOL3, "QUAD:LI24:713:BMAX")
  field(DOL4, "QUAD:LI24:713:BMIN")
  field(DOL5, "QUAD:LI24:713:BMIN")
  field(DOL6, "QUAD:LI24:713:BMIN")
  field(LNK1, "QUAD:LI24:713:BMAGX.HOPR")
  field(LNK2, "QUAD:LI24:713:BMAGY.HOPR")
  field(LNK3, "QUAD:LI24:713:BLEM.HOPR")
  field(LNK4, "QUAD:LI24:713:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI24:713:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI24:713:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:713:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:713:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI24:713:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI24:713:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI24:713:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:713:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:713:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:713:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:713:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:713:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI24:713:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI24:713:EDES NPP MS")
  field(INPB, "QUAD:LI24:713:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI24:740:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI24:740:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI24:740:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI24:740:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI24:740:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI24:740:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI24:740:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI24:740:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI24:740:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI24:740:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI24:740:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI24:740:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI24:740:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI24:740:EDES.PROC PP")
    field(LNK2, "QUAD:LI24:740:EACT.PROC PP")
    field(LNK3, "QUAD:LI24:740:EERR.DISA PP")
    field(LNK4, "QUAD:LI24:740:ECON.PROC PP")
    field(LNK5, "QUAD:LI24:740:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI24:740:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI24:740:BLEM.PROC PP")
    field(LNK8, "QUAD:LI24:740:BMOD.PROC PP")
    field(LNK9, "QUAD:LI24:740:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI24:740:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI24:740:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI24:740:BMAX")
  field(DOL2, "QUAD:LI24:740:BMAX")
  field(DOL3, "QUAD:LI24:740:BMAX")
  field(DOL4, "QUAD:LI24:740:BMIN")
  field(DOL5, "QUAD:LI24:740:BMIN")
  field(DOL6, "QUAD:LI24:740:BMIN")
  field(LNK1, "QUAD:LI24:740:BMAGX.HOPR")
  field(LNK2, "QUAD:LI24:740:BMAGY.HOPR")
  field(LNK3, "QUAD:LI24:740:BLEM.HOPR")
  field(LNK4, "QUAD:LI24:740:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI24:740:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI24:740:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:740:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:740:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI24:740:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI24:740:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI24:740:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:740:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:740:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:740:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:740:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:740:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI24:740:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI24:740:EDES NPP MS")
  field(INPB, "QUAD:LI24:740:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI24:860:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI24:860:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI24:860:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI24:860:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI24:860:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI24:860:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI24:860:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI24:860:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI24:860:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI24:860:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI24:860:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI24:860:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI24:860:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI24:860:EDES.PROC PP")
    field(LNK2, "QUAD:LI24:860:EACT.PROC PP")
    field(LNK3, "QUAD:LI24:860:EERR.DISA PP")
    field(LNK4, "QUAD:LI24:860:ECON.PROC PP")
    field(LNK5, "QUAD:LI24:860:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI24:860:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI24:860:BLEM.PROC PP")
    field(LNK8, "QUAD:LI24:860:BMOD.PROC PP")
    field(LNK9, "QUAD:LI24:860:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI24:860:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI24:860:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI24:860:BMAX")
  field(DOL2, "QUAD:LI24:860:BMAX")
  field(DOL3, "QUAD:LI24:860:BMAX")
  field(DOL4, "QUAD:LI24:860:BMIN")
  field(DOL5, "QUAD:LI24:860:BMIN")
  field(DOL6, "QUAD:LI24:860:BMIN")
  field(LNK1, "QUAD:LI24:860:BMAGX.HOPR")
  field(LNK2, "QUAD:LI24:860:BMAGY.HOPR")
  field(LNK3, "QUAD:LI24:860:BLEM.HOPR")
  field(LNK4, "QUAD:LI24:860:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI24:860:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI24:860:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:860:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:860:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI24:860:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI24:860:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI24:860:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:860:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:860:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:860:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:860:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:860:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI24:860:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI24:860:EDES NPP MS")
  field(INPB, "QUAD:LI24:860:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI24:892:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI24:892:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI24:892:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI24:892:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI24:892:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI24:892:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI24:892:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI24:892:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI24:892:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI24:892:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI24:892:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI24:892:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI24:892:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI24:892:EDES.PROC PP")
    field(LNK2, "QUAD:LI24:892:EACT.PROC PP")
    field(LNK3, "QUAD:LI24:892:EERR.DISA PP")
    field(LNK4, "QUAD:LI24:892:ECON.PROC PP")
    field(LNK5, "QUAD:LI24:892:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI24:892:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI24:892:BLEM.PROC PP")
    field(LNK8, "QUAD:LI24:892:BMOD.PROC PP")
    field(LNK9, "QUAD:LI24:892:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI24:892:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI24:892:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI24:892:BMAX")
  field(DOL2, "QUAD:LI24:892:BMAX")
  field(DOL3, "QUAD:LI24:892:BMAX")
  field(DOL4, "QUAD:LI24:892:BMIN")
  field(DOL5, "QUAD:LI24:892:BMIN")
  field(DOL6, "QUAD:LI24:892:BMIN")
  field(LNK1, "QUAD:LI24:892:BMAGX.HOPR")
  field(LNK2, "QUAD:LI24:892:BMAGY.HOPR")
  field(LNK3, "QUAD:LI24:892:BLEM.HOPR")
  field(LNK4, "QUAD:LI24:892:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI24:892:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI24:892:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:892:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:892:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI24:892:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI24:892:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI24:892:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:892:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:892:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:892:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:892:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:892:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI24:892:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI24:892:EDES NPP MS")
  field(INPB, "QUAD:LI24:892:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI24:901:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI24:901:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI24:901:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI24:901:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI24:901:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI24:901:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI24:901:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI24:901:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI24:901:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI24:901:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI24:901:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI24:901:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI24:901:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI24:901:EDES.PROC PP")
    field(LNK2, "QUAD:LI24:901:EACT.PROC PP")
    field(LNK3, "QUAD:LI24:901:EERR.DISA PP")
    field(LNK4, "QUAD:LI24:901:ECON.PROC PP")
    field(LNK5, "QUAD:LI24:901:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI24:901:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI24:901:BLEM.PROC PP")
    field(LNK8, "QUAD:LI24:901:BMOD.PROC PP")
    field(LNK9, "QUAD:LI24:901:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI24:901:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI24:901:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI24:901:BMAX")
  field(DOL2, "QUAD:LI24:901:BMAX")
  field(DOL3, "QUAD:LI24:901:BMAX")
  field(DOL4, "QUAD:LI24:901:BMIN")
  field(DOL5, "QUAD:LI24:901:BMIN")
  field(DOL6, "QUAD:LI24:901:BMIN")
  field(LNK1, "QUAD:LI24:901:BMAGX.HOPR")
  field(LNK2, "QUAD:LI24:901:BMAGY.HOPR")
  field(LNK3, "QUAD:LI24:901:BLEM.HOPR")
  field(LNK4, "QUAD:LI24:901:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI24:901:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI24:901:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:901:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:901:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI24:901:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI24:901:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI24:901:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:901:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:901:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:901:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:901:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI24:901:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI24:901:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI24:901:EDES NPP MS")
  field(INPB, "QUAD:LI24:901:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI24:202:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI24:202:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI24:202:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI24:202:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI24:202:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI24:202:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI24:202:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI24:202:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI24:202:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI24:202:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI24:202:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI24:202:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI24:202:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI24:202:EDES.PROC PP")
    field(LNK2, "XCOR:LI24:202:EACT.PROC PP")
    field(LNK3, "XCOR:LI24:202:EERR.DISA PP")
    field(LNK4, "XCOR:LI24:202:ECON.PROC PP")
    field(LNK5, "XCOR:LI24:202:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI24:202:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI24:202:BLEM.PROC PP")
    field(LNK8, "XCOR:LI24:202:BMOD.PROC PP")
    field(LNK9, "XCOR:LI24:202:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI24:202:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI24:202:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI24:202:BMAX")
  field(DOL2, "XCOR:LI24:202:BMAX")
  field(DOL3, "XCOR:LI24:202:BMAX")
  field(DOL4, "XCOR:LI24:202:BMIN")
  field(DOL5, "XCOR:LI24:202:BMIN")
  field(DOL6, "XCOR:LI24:202:BMIN")
  field(LNK1, "XCOR:LI24:202:BMAGX.HOPR")
  field(LNK2, "XCOR:LI24:202:BMAGY.HOPR")
  field(LNK3, "XCOR:LI24:202:BLEM.HOPR")
  field(LNK4, "XCOR:LI24:202:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI24:202:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI24:202:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI24:202:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI24:202:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI24:202:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI24:202:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI24:202:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:202:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:202:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI24:202:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:202:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI24:202:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI24:202:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI24:202:EDES NPP MS")
  field(INPB, "XCOR:LI24:202:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI24:302:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI24:302:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI24:302:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI24:302:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI24:302:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI24:302:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI24:302:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI24:302:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI24:302:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI24:302:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI24:302:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI24:302:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI24:302:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI24:302:EDES.PROC PP")
    field(LNK2, "XCOR:LI24:302:EACT.PROC PP")
    field(LNK3, "XCOR:LI24:302:EERR.DISA PP")
    field(LNK4, "XCOR:LI24:302:ECON.PROC PP")
    field(LNK5, "XCOR:LI24:302:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI24:302:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI24:302:BLEM.PROC PP")
    field(LNK8, "XCOR:LI24:302:BMOD.PROC PP")
    field(LNK9, "XCOR:LI24:302:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI24:302:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI24:302:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI24:302:BMAX")
  field(DOL2, "XCOR:LI24:302:BMAX")
  field(DOL3, "XCOR:LI24:302:BMAX")
  field(DOL4, "XCOR:LI24:302:BMIN")
  field(DOL5, "XCOR:LI24:302:BMIN")
  field(DOL6, "XCOR:LI24:302:BMIN")
  field(LNK1, "XCOR:LI24:302:BMAGX.HOPR")
  field(LNK2, "XCOR:LI24:302:BMAGY.HOPR")
  field(LNK3, "XCOR:LI24:302:BLEM.HOPR")
  field(LNK4, "XCOR:LI24:302:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI24:302:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI24:302:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI24:302:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI24:302:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI24:302:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI24:302:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI24:302:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:302:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:302:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI24:302:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:302:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI24:302:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI24:302:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI24:302:EDES NPP MS")
  field(INPB, "XCOR:LI24:302:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI24:402:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI24:402:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI24:402:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI24:402:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI24:402:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI24:402:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI24:402:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI24:402:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI24:402:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI24:402:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI24:402:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI24:402:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI24:402:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI24:402:EDES.PROC PP")
    field(LNK2, "XCOR:LI24:402:EACT.PROC PP")
    field(LNK3, "XCOR:LI24:402:EERR.DISA PP")
    field(LNK4, "XCOR:LI24:402:ECON.PROC PP")
    field(LNK5, "XCOR:LI24:402:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI24:402:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI24:402:BLEM.PROC PP")
    field(LNK8, "XCOR:LI24:402:BMOD.PROC PP")
    field(LNK9, "XCOR:LI24:402:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI24:402:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI24:402:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI24:402:BMAX")
  field(DOL2, "XCOR:LI24:402:BMAX")
  field(DOL3, "XCOR:LI24:402:BMAX")
  field(DOL4, "XCOR:LI24:402:BMIN")
  field(DOL5, "XCOR:LI24:402:BMIN")
  field(DOL6, "XCOR:LI24:402:BMIN")
  field(LNK1, "XCOR:LI24:402:BMAGX.HOPR")
  field(LNK2, "XCOR:LI24:402:BMAGY.HOPR")
  field(LNK3, "XCOR:LI24:402:BLEM.HOPR")
  field(LNK4, "XCOR:LI24:402:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI24:402:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI24:402:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI24:402:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI24:402:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI24:402:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI24:402:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI24:402:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:402:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:402:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI24:402:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:402:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI24:402:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI24:402:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI24:402:EDES NPP MS")
  field(INPB, "XCOR:LI24:402:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI24:502:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI24:502:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI24:502:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI24:502:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI24:502:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI24:502:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI24:502:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI24:502:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI24:502:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI24:502:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI24:502:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI24:502:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI24:502:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI24:502:EDES.PROC PP")
    field(LNK2, "XCOR:LI24:502:EACT.PROC PP")
    field(LNK3, "XCOR:LI24:502:EERR.DISA PP")
    field(LNK4, "XCOR:LI24:502:ECON.PROC PP")
    field(LNK5, "XCOR:LI24:502:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI24:502:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI24:502:BLEM.PROC PP")
    field(LNK8, "XCOR:LI24:502:BMOD.PROC PP")
    field(LNK9, "XCOR:LI24:502:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI24:502:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI24:502:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI24:502:BMAX")
  field(DOL2, "XCOR:LI24:502:BMAX")
  field(DOL3, "XCOR:LI24:502:BMAX")
  field(DOL4, "XCOR:LI24:502:BMIN")
  field(DOL5, "XCOR:LI24:502:BMIN")
  field(DOL6, "XCOR:LI24:502:BMIN")
  field(LNK1, "XCOR:LI24:502:BMAGX.HOPR")
  field(LNK2, "XCOR:LI24:502:BMAGY.HOPR")
  field(LNK3, "XCOR:LI24:502:BLEM.HOPR")
  field(LNK4, "XCOR:LI24:502:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI24:502:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI24:502:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI24:502:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI24:502:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI24:502:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI24:502:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI24:502:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:502:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:502:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI24:502:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:502:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI24:502:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI24:502:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI24:502:EDES NPP MS")
  field(INPB, "XCOR:LI24:502:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI24:602:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI24:602:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI24:602:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI24:602:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI24:602:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI24:602:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI24:602:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI24:602:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI24:602:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI24:602:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI24:602:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI24:602:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI24:602:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI24:602:EDES.PROC PP")
    field(LNK2, "XCOR:LI24:602:EACT.PROC PP")
    field(LNK3, "XCOR:LI24:602:EERR.DISA PP")
    field(LNK4, "XCOR:LI24:602:ECON.PROC PP")
    field(LNK5, "XCOR:LI24:602:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI24:602:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI24:602:BLEM.PROC PP")
    field(LNK8, "XCOR:LI24:602:BMOD.PROC PP")
    field(LNK9, "XCOR:LI24:602:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI24:602:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI24:602:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI24:602:BMAX")
  field(DOL2, "XCOR:LI24:602:BMAX")
  field(DOL3, "XCOR:LI24:602:BMAX")
  field(DOL4, "XCOR:LI24:602:BMIN")
  field(DOL5, "XCOR:LI24:602:BMIN")
  field(DOL6, "XCOR:LI24:602:BMIN")
  field(LNK1, "XCOR:LI24:602:BMAGX.HOPR")
  field(LNK2, "XCOR:LI24:602:BMAGY.HOPR")
  field(LNK3, "XCOR:LI24:602:BLEM.HOPR")
  field(LNK4, "XCOR:LI24:602:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI24:602:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI24:602:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI24:602:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI24:602:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI24:602:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI24:602:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI24:602:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:602:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:602:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI24:602:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:602:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI24:602:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI24:602:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI24:602:EDES NPP MS")
  field(INPB, "XCOR:LI24:602:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI24:702:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI24:702:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI24:702:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI24:702:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI24:702:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI24:702:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI24:702:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI24:702:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI24:702:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI24:702:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI24:702:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI24:702:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI24:702:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI24:702:EDES.PROC PP")
    field(LNK2, "XCOR:LI24:702:EACT.PROC PP")
    field(LNK3, "XCOR:LI24:702:EERR.DISA PP")
    field(LNK4, "XCOR:LI24:702:ECON.PROC PP")
    field(LNK5, "XCOR:LI24:702:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI24:702:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI24:702:BLEM.PROC PP")
    field(LNK8, "XCOR:LI24:702:BMOD.PROC PP")
    field(LNK9, "XCOR:LI24:702:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI24:702:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI24:702:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI24:702:BMAX")
  field(DOL2, "XCOR:LI24:702:BMAX")
  field(DOL3, "XCOR:LI24:702:BMAX")
  field(DOL4, "XCOR:LI24:702:BMIN")
  field(DOL5, "XCOR:LI24:702:BMIN")
  field(DOL6, "XCOR:LI24:702:BMIN")
  field(LNK1, "XCOR:LI24:702:BMAGX.HOPR")
  field(LNK2, "XCOR:LI24:702:BMAGY.HOPR")
  field(LNK3, "XCOR:LI24:702:BLEM.HOPR")
  field(LNK4, "XCOR:LI24:702:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI24:702:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI24:702:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI24:702:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI24:702:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI24:702:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI24:702:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI24:702:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:702:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:702:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI24:702:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:702:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI24:702:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI24:702:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI24:702:EDES NPP MS")
  field(INPB, "XCOR:LI24:702:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI24:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI24:900:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI24:900:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI24:900:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI24:900:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI24:900:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI24:900:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI24:900:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI24:900:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI24:900:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI24:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI24:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI24:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI24:900:EDES.PROC PP")
    field(LNK2, "XCOR:LI24:900:EACT.PROC PP")
    field(LNK3, "XCOR:LI24:900:EERR.DISA PP")
    field(LNK4, "XCOR:LI24:900:ECON.PROC PP")
    field(LNK5, "XCOR:LI24:900:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI24:900:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI24:900:BLEM.PROC PP")
    field(LNK8, "XCOR:LI24:900:BMOD.PROC PP")
    field(LNK9, "XCOR:LI24:900:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI24:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI24:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI24:900:BMAX")
  field(DOL2, "XCOR:LI24:900:BMAX")
  field(DOL3, "XCOR:LI24:900:BMAX")
  field(DOL4, "XCOR:LI24:900:BMIN")
  field(DOL5, "XCOR:LI24:900:BMIN")
  field(DOL6, "XCOR:LI24:900:BMIN")
  field(LNK1, "XCOR:LI24:900:BMAGX.HOPR")
  field(LNK2, "XCOR:LI24:900:BMAGY.HOPR")
  field(LNK3, "XCOR:LI24:900:BLEM.HOPR")
  field(LNK4, "XCOR:LI24:900:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI24:900:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI24:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI24:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI24:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI24:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI24:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI24:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI24:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI24:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI24:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI24:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI24:900:EDES NPP MS")
  field(INPB, "XCOR:LI24:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI24:203:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI24:203:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI24:203:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI24:203:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI24:203:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI24:203:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI24:203:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI24:203:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI24:203:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI24:203:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI24:203:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI24:203:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI24:203:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI24:203:EDES.PROC PP")
    field(LNK2, "YCOR:LI24:203:EACT.PROC PP")
    field(LNK3, "YCOR:LI24:203:EERR.DISA PP")
    field(LNK4, "YCOR:LI24:203:ECON.PROC PP")
    field(LNK5, "YCOR:LI24:203:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI24:203:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI24:203:BLEM.PROC PP")
    field(LNK8, "YCOR:LI24:203:BMOD.PROC PP")
    field(LNK9, "YCOR:LI24:203:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI24:203:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI24:203:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI24:203:BMAX")
  field(DOL2, "YCOR:LI24:203:BMAX")
  field(DOL3, "YCOR:LI24:203:BMAX")
  field(DOL4, "YCOR:LI24:203:BMIN")
  field(DOL5, "YCOR:LI24:203:BMIN")
  field(DOL6, "YCOR:LI24:203:BMIN")
  field(LNK1, "YCOR:LI24:203:BMAGX.HOPR")
  field(LNK2, "YCOR:LI24:203:BMAGY.HOPR")
  field(LNK3, "YCOR:LI24:203:BLEM.HOPR")
  field(LNK4, "YCOR:LI24:203:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI24:203:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI24:203:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI24:203:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI24:203:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI24:203:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI24:203:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI24:203:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:203:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:203:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI24:203:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:203:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI24:203:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI24:203:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI24:203:EDES NPP MS")
  field(INPB, "YCOR:LI24:203:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI24:303:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI24:303:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI24:303:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI24:303:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI24:303:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI24:303:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI24:303:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI24:303:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI24:303:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI24:303:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI24:303:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI24:303:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI24:303:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI24:303:EDES.PROC PP")
    field(LNK2, "YCOR:LI24:303:EACT.PROC PP")
    field(LNK3, "YCOR:LI24:303:EERR.DISA PP")
    field(LNK4, "YCOR:LI24:303:ECON.PROC PP")
    field(LNK5, "YCOR:LI24:303:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI24:303:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI24:303:BLEM.PROC PP")
    field(LNK8, "YCOR:LI24:303:BMOD.PROC PP")
    field(LNK9, "YCOR:LI24:303:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI24:303:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI24:303:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI24:303:BMAX")
  field(DOL2, "YCOR:LI24:303:BMAX")
  field(DOL3, "YCOR:LI24:303:BMAX")
  field(DOL4, "YCOR:LI24:303:BMIN")
  field(DOL5, "YCOR:LI24:303:BMIN")
  field(DOL6, "YCOR:LI24:303:BMIN")
  field(LNK1, "YCOR:LI24:303:BMAGX.HOPR")
  field(LNK2, "YCOR:LI24:303:BMAGY.HOPR")
  field(LNK3, "YCOR:LI24:303:BLEM.HOPR")
  field(LNK4, "YCOR:LI24:303:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI24:303:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI24:303:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI24:303:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI24:303:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI24:303:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI24:303:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI24:303:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:303:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:303:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI24:303:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:303:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI24:303:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI24:303:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI24:303:EDES NPP MS")
  field(INPB, "YCOR:LI24:303:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI24:403:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI24:403:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI24:403:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI24:403:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI24:403:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI24:403:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI24:403:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI24:403:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI24:403:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI24:403:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI24:403:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI24:403:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI24:403:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI24:403:EDES.PROC PP")
    field(LNK2, "YCOR:LI24:403:EACT.PROC PP")
    field(LNK3, "YCOR:LI24:403:EERR.DISA PP")
    field(LNK4, "YCOR:LI24:403:ECON.PROC PP")
    field(LNK5, "YCOR:LI24:403:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI24:403:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI24:403:BLEM.PROC PP")
    field(LNK8, "YCOR:LI24:403:BMOD.PROC PP")
    field(LNK9, "YCOR:LI24:403:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI24:403:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI24:403:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI24:403:BMAX")
  field(DOL2, "YCOR:LI24:403:BMAX")
  field(DOL3, "YCOR:LI24:403:BMAX")
  field(DOL4, "YCOR:LI24:403:BMIN")
  field(DOL5, "YCOR:LI24:403:BMIN")
  field(DOL6, "YCOR:LI24:403:BMIN")
  field(LNK1, "YCOR:LI24:403:BMAGX.HOPR")
  field(LNK2, "YCOR:LI24:403:BMAGY.HOPR")
  field(LNK3, "YCOR:LI24:403:BLEM.HOPR")
  field(LNK4, "YCOR:LI24:403:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI24:403:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI24:403:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI24:403:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI24:403:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI24:403:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI24:403:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI24:403:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:403:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:403:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI24:403:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:403:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI24:403:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI24:403:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI24:403:EDES NPP MS")
  field(INPB, "YCOR:LI24:403:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI24:503:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI24:503:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI24:503:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI24:503:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI24:503:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI24:503:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI24:503:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI24:503:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI24:503:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI24:503:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI24:503:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI24:503:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI24:503:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI24:503:EDES.PROC PP")
    field(LNK2, "YCOR:LI24:503:EACT.PROC PP")
    field(LNK3, "YCOR:LI24:503:EERR.DISA PP")
    field(LNK4, "YCOR:LI24:503:ECON.PROC PP")
    field(LNK5, "YCOR:LI24:503:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI24:503:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI24:503:BLEM.PROC PP")
    field(LNK8, "YCOR:LI24:503:BMOD.PROC PP")
    field(LNK9, "YCOR:LI24:503:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI24:503:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI24:503:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI24:503:BMAX")
  field(DOL2, "YCOR:LI24:503:BMAX")
  field(DOL3, "YCOR:LI24:503:BMAX")
  field(DOL4, "YCOR:LI24:503:BMIN")
  field(DOL5, "YCOR:LI24:503:BMIN")
  field(DOL6, "YCOR:LI24:503:BMIN")
  field(LNK1, "YCOR:LI24:503:BMAGX.HOPR")
  field(LNK2, "YCOR:LI24:503:BMAGY.HOPR")
  field(LNK3, "YCOR:LI24:503:BLEM.HOPR")
  field(LNK4, "YCOR:LI24:503:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI24:503:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI24:503:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI24:503:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI24:503:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI24:503:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI24:503:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI24:503:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:503:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:503:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI24:503:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:503:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI24:503:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI24:503:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI24:503:EDES NPP MS")
  field(INPB, "YCOR:LI24:503:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI24:603:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI24:603:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI24:603:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI24:603:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI24:603:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI24:603:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI24:603:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI24:603:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI24:603:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI24:603:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI24:603:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI24:603:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI24:603:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI24:603:EDES.PROC PP")
    field(LNK2, "YCOR:LI24:603:EACT.PROC PP")
    field(LNK3, "YCOR:LI24:603:EERR.DISA PP")
    field(LNK4, "YCOR:LI24:603:ECON.PROC PP")
    field(LNK5, "YCOR:LI24:603:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI24:603:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI24:603:BLEM.PROC PP")
    field(LNK8, "YCOR:LI24:603:BMOD.PROC PP")
    field(LNK9, "YCOR:LI24:603:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI24:603:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI24:603:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI24:603:BMAX")
  field(DOL2, "YCOR:LI24:603:BMAX")
  field(DOL3, "YCOR:LI24:603:BMAX")
  field(DOL4, "YCOR:LI24:603:BMIN")
  field(DOL5, "YCOR:LI24:603:BMIN")
  field(DOL6, "YCOR:LI24:603:BMIN")
  field(LNK1, "YCOR:LI24:603:BMAGX.HOPR")
  field(LNK2, "YCOR:LI24:603:BMAGY.HOPR")
  field(LNK3, "YCOR:LI24:603:BLEM.HOPR")
  field(LNK4, "YCOR:LI24:603:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI24:603:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI24:603:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI24:603:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI24:603:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI24:603:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI24:603:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI24:603:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:603:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:603:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI24:603:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:603:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI24:603:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI24:603:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI24:603:EDES NPP MS")
  field(INPB, "YCOR:LI24:603:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI24:703:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI24:703:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI24:703:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI24:703:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI24:703:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI24:703:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI24:703:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI24:703:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI24:703:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI24:703:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI24:703:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI24:703:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI24:703:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI24:703:EDES.PROC PP")
    field(LNK2, "YCOR:LI24:703:EACT.PROC PP")
    field(LNK3, "YCOR:LI24:703:EERR.DISA PP")
    field(LNK4, "YCOR:LI24:703:ECON.PROC PP")
    field(LNK5, "YCOR:LI24:703:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI24:703:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI24:703:BLEM.PROC PP")
    field(LNK8, "YCOR:LI24:703:BMOD.PROC PP")
    field(LNK9, "YCOR:LI24:703:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI24:703:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI24:703:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI24:703:BMAX")
  field(DOL2, "YCOR:LI24:703:BMAX")
  field(DOL3, "YCOR:LI24:703:BMAX")
  field(DOL4, "YCOR:LI24:703:BMIN")
  field(DOL5, "YCOR:LI24:703:BMIN")
  field(DOL6, "YCOR:LI24:703:BMIN")
  field(LNK1, "YCOR:LI24:703:BMAGX.HOPR")
  field(LNK2, "YCOR:LI24:703:BMAGY.HOPR")
  field(LNK3, "YCOR:LI24:703:BLEM.HOPR")
  field(LNK4, "YCOR:LI24:703:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI24:703:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI24:703:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI24:703:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI24:703:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI24:703:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI24:703:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI24:703:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:703:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:703:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI24:703:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:703:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI24:703:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI24:703:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI24:703:EDES NPP MS")
  field(INPB, "YCOR:LI24:703:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI24:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI24:900:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI24:900:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI24:900:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI24:900:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI24:900:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI24:900:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI24:900:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI24:900:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI24:900:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI24:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI24:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI24:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI24:900:EDES.PROC PP")
    field(LNK2, "YCOR:LI24:900:EACT.PROC PP")
    field(LNK3, "YCOR:LI24:900:EERR.DISA PP")
    field(LNK4, "YCOR:LI24:900:ECON.PROC PP")
    field(LNK5, "YCOR:LI24:900:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI24:900:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI24:900:BLEM.PROC PP")
    field(LNK8, "YCOR:LI24:900:BMOD.PROC PP")
    field(LNK9, "YCOR:LI24:900:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI24:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI24:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI24:900:BMAX")
  field(DOL2, "YCOR:LI24:900:BMAX")
  field(DOL3, "YCOR:LI24:900:BMAX")
  field(DOL4, "YCOR:LI24:900:BMIN")
  field(DOL5, "YCOR:LI24:900:BMIN")
  field(DOL6, "YCOR:LI24:900:BMIN")
  field(LNK1, "YCOR:LI24:900:BMAGX.HOPR")
  field(LNK2, "YCOR:LI24:900:BMAGY.HOPR")
  field(LNK3, "YCOR:LI24:900:BLEM.HOPR")
  field(LNK4, "YCOR:LI24:900:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI24:900:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI24:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI24:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI24:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI24:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI24:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI24:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI24:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI24:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI24:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI24:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI24:900:EDES NPP MS")
  field(INPB, "YCOR:LI24:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LI30:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "LGPS:LI30:2:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LI30:2:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LI30:2:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LI30:2:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LI30:2:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LI30:2:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LI30:2:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LI30:2:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LI30:2:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LI30:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LI30:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LI30:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LI30:2:EDES.PROC PP")
    field(LNK2, "LGPS:LI30:2:EACT.PROC PP")
    field(LNK3, "LGPS:LI30:2:EERR.DISA PP")
    field(LNK4, "LGPS:LI30:2:ECON.PROC PP")
    field(LNK5, "LGPS:LI30:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:LI30:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:LI30:2:BLEM.PROC PP")
    field(LNK8, "LGPS:LI30:2:BMOD.PROC PP")
    field(LNK9, "LGPS:LI30:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LI30:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LI30:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LI30:2:BMAX")
  field(DOL2, "LGPS:LI30:2:BMAX")
  field(DOL3, "LGPS:LI30:2:BMAX")
  field(DOL4, "LGPS:LI30:2:BMIN")
  field(DOL5, "LGPS:LI30:2:BMIN")
  field(DOL6, "LGPS:LI30:2:BMIN")
  field(LNK1, "LGPS:LI30:2:BMAGX.HOPR")
  field(LNK2, "LGPS:LI30:2:BMAGY.HOPR")
  field(LNK3, "LGPS:LI30:2:BLEM.HOPR")
  field(LNK4, "LGPS:LI30:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LI30:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LI30:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LI30:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LI30:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LI30:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LI30:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LI30:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI30:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI30:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI30:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LI30:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LI30:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LI30:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LI30:2:EDES NPP MS")
  field(INPB, "LGPS:LI30:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI30:201:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI30:201:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI30:201:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI30:201:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI30:201:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI30:201:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI30:201:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI30:201:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI30:201:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI30:201:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI30:201:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI30:201:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI30:201:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI30:201:EDES.PROC PP")
    field(LNK2, "QUAD:LI30:201:EACT.PROC PP")
    field(LNK3, "QUAD:LI30:201:EERR.DISA PP")
    field(LNK4, "QUAD:LI30:201:ECON.PROC PP")
    field(LNK5, "QUAD:LI30:201:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI30:201:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI30:201:BLEM.PROC PP")
    field(LNK8, "QUAD:LI30:201:BMOD.PROC PP")
    field(LNK9, "QUAD:LI30:201:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI30:201:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI30:201:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI30:201:BMAX")
  field(DOL2, "QUAD:LI30:201:BMAX")
  field(DOL3, "QUAD:LI30:201:BMAX")
  field(DOL4, "QUAD:LI30:201:BMIN")
  field(DOL5, "QUAD:LI30:201:BMIN")
  field(DOL6, "QUAD:LI30:201:BMIN")
  field(LNK1, "QUAD:LI30:201:BMAGX.HOPR")
  field(LNK2, "QUAD:LI30:201:BMAGY.HOPR")
  field(LNK3, "QUAD:LI30:201:BLEM.HOPR")
  field(LNK4, "QUAD:LI30:201:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI30:201:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI30:201:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI30:201:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI30:201:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI30:201:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI30:201:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI30:201:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:201:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:201:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI30:201:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:201:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI30:201:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI30:201:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI30:201:EDES NPP MS")
  field(INPB, "QUAD:LI30:201:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI30:301:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI30:301:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI30:301:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI30:301:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI30:301:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI30:301:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI30:301:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI30:301:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI30:301:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI30:301:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI30:301:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI30:301:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI30:301:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI30:301:EDES.PROC PP")
    field(LNK2, "QUAD:LI30:301:EACT.PROC PP")
    field(LNK3, "QUAD:LI30:301:EERR.DISA PP")
    field(LNK4, "QUAD:LI30:301:ECON.PROC PP")
    field(LNK5, "QUAD:LI30:301:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI30:301:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI30:301:BLEM.PROC PP")
    field(LNK8, "QUAD:LI30:301:BMOD.PROC PP")
    field(LNK9, "QUAD:LI30:301:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI30:301:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI30:301:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI30:301:BMAX")
  field(DOL2, "QUAD:LI30:301:BMAX")
  field(DOL3, "QUAD:LI30:301:BMAX")
  field(DOL4, "QUAD:LI30:301:BMIN")
  field(DOL5, "QUAD:LI30:301:BMIN")
  field(DOL6, "QUAD:LI30:301:BMIN")
  field(LNK1, "QUAD:LI30:301:BMAGX.HOPR")
  field(LNK2, "QUAD:LI30:301:BMAGY.HOPR")
  field(LNK3, "QUAD:LI30:301:BLEM.HOPR")
  field(LNK4, "QUAD:LI30:301:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI30:301:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI30:301:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI30:301:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI30:301:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI30:301:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI30:301:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI30:301:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:301:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:301:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI30:301:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:301:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI30:301:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI30:301:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI30:301:EDES NPP MS")
  field(INPB, "QUAD:LI30:301:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI30:401:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI30:401:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI30:401:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI30:401:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI30:401:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI30:401:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI30:401:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI30:401:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI30:401:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI30:401:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI30:401:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI30:401:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI30:401:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI30:401:EDES.PROC PP")
    field(LNK2, "QUAD:LI30:401:EACT.PROC PP")
    field(LNK3, "QUAD:LI30:401:EERR.DISA PP")
    field(LNK4, "QUAD:LI30:401:ECON.PROC PP")
    field(LNK5, "QUAD:LI30:401:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI30:401:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI30:401:BLEM.PROC PP")
    field(LNK8, "QUAD:LI30:401:BMOD.PROC PP")
    field(LNK9, "QUAD:LI30:401:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI30:401:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI30:401:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI30:401:BMAX")
  field(DOL2, "QUAD:LI30:401:BMAX")
  field(DOL3, "QUAD:LI30:401:BMAX")
  field(DOL4, "QUAD:LI30:401:BMIN")
  field(DOL5, "QUAD:LI30:401:BMIN")
  field(DOL6, "QUAD:LI30:401:BMIN")
  field(LNK1, "QUAD:LI30:401:BMAGX.HOPR")
  field(LNK2, "QUAD:LI30:401:BMAGY.HOPR")
  field(LNK3, "QUAD:LI30:401:BLEM.HOPR")
  field(LNK4, "QUAD:LI30:401:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI30:401:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI30:401:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI30:401:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI30:401:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI30:401:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI30:401:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI30:401:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:401:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:401:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI30:401:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:401:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI30:401:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI30:401:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI30:401:EDES NPP MS")
  field(INPB, "QUAD:LI30:401:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI30:501:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI30:501:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI30:501:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI30:501:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI30:501:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI30:501:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI30:501:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI30:501:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI30:501:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI30:501:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI30:501:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI30:501:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI30:501:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI30:501:EDES.PROC PP")
    field(LNK2, "QUAD:LI30:501:EACT.PROC PP")
    field(LNK3, "QUAD:LI30:501:EERR.DISA PP")
    field(LNK4, "QUAD:LI30:501:ECON.PROC PP")
    field(LNK5, "QUAD:LI30:501:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI30:501:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI30:501:BLEM.PROC PP")
    field(LNK8, "QUAD:LI30:501:BMOD.PROC PP")
    field(LNK9, "QUAD:LI30:501:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI30:501:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI30:501:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI30:501:BMAX")
  field(DOL2, "QUAD:LI30:501:BMAX")
  field(DOL3, "QUAD:LI30:501:BMAX")
  field(DOL4, "QUAD:LI30:501:BMIN")
  field(DOL5, "QUAD:LI30:501:BMIN")
  field(DOL6, "QUAD:LI30:501:BMIN")
  field(LNK1, "QUAD:LI30:501:BMAGX.HOPR")
  field(LNK2, "QUAD:LI30:501:BMAGY.HOPR")
  field(LNK3, "QUAD:LI30:501:BLEM.HOPR")
  field(LNK4, "QUAD:LI30:501:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI30:501:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI30:501:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI30:501:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI30:501:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI30:501:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI30:501:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI30:501:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:501:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:501:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI30:501:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:501:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI30:501:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI30:501:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI30:501:EDES NPP MS")
  field(INPB, "QUAD:LI30:501:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI30:601:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI30:601:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI30:601:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI30:601:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI30:601:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI30:601:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI30:601:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI30:601:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI30:601:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI30:601:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI30:601:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI30:601:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI30:601:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI30:601:EDES.PROC PP")
    field(LNK2, "QUAD:LI30:601:EACT.PROC PP")
    field(LNK3, "QUAD:LI30:601:EERR.DISA PP")
    field(LNK4, "QUAD:LI30:601:ECON.PROC PP")
    field(LNK5, "QUAD:LI30:601:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI30:601:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI30:601:BLEM.PROC PP")
    field(LNK8, "QUAD:LI30:601:BMOD.PROC PP")
    field(LNK9, "QUAD:LI30:601:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI30:601:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI30:601:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI30:601:BMAX")
  field(DOL2, "QUAD:LI30:601:BMAX")
  field(DOL3, "QUAD:LI30:601:BMAX")
  field(DOL4, "QUAD:LI30:601:BMIN")
  field(DOL5, "QUAD:LI30:601:BMIN")
  field(DOL6, "QUAD:LI30:601:BMIN")
  field(LNK1, "QUAD:LI30:601:BMAGX.HOPR")
  field(LNK2, "QUAD:LI30:601:BMAGY.HOPR")
  field(LNK3, "QUAD:LI30:601:BLEM.HOPR")
  field(LNK4, "QUAD:LI30:601:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI30:601:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI30:601:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI30:601:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI30:601:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI30:601:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI30:601:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI30:601:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:601:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:601:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI30:601:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:601:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI30:601:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI30:601:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI30:601:EDES NPP MS")
  field(INPB, "QUAD:LI30:601:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI30:701:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI30:701:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI30:701:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI30:701:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI30:701:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI30:701:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI30:701:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI30:701:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI30:701:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI30:701:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI30:701:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI30:701:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI30:701:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI30:701:EDES.PROC PP")
    field(LNK2, "QUAD:LI30:701:EACT.PROC PP")
    field(LNK3, "QUAD:LI30:701:EERR.DISA PP")
    field(LNK4, "QUAD:LI30:701:ECON.PROC PP")
    field(LNK5, "QUAD:LI30:701:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI30:701:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI30:701:BLEM.PROC PP")
    field(LNK8, "QUAD:LI30:701:BMOD.PROC PP")
    field(LNK9, "QUAD:LI30:701:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI30:701:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI30:701:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI30:701:BMAX")
  field(DOL2, "QUAD:LI30:701:BMAX")
  field(DOL3, "QUAD:LI30:701:BMAX")
  field(DOL4, "QUAD:LI30:701:BMIN")
  field(DOL5, "QUAD:LI30:701:BMIN")
  field(DOL6, "QUAD:LI30:701:BMIN")
  field(LNK1, "QUAD:LI30:701:BMAGX.HOPR")
  field(LNK2, "QUAD:LI30:701:BMAGY.HOPR")
  field(LNK3, "QUAD:LI30:701:BLEM.HOPR")
  field(LNK4, "QUAD:LI30:701:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI30:701:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI30:701:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI30:701:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI30:701:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI30:701:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI30:701:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI30:701:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:701:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:701:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI30:701:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:701:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI30:701:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI30:701:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI30:701:EDES NPP MS")
  field(INPB, "QUAD:LI30:701:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI30:801:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI30:801:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI30:801:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI30:801:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI30:801:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI30:801:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI30:801:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI30:801:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI30:801:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI30:801:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI30:801:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI30:801:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI30:801:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI30:801:EDES.PROC PP")
    field(LNK2, "QUAD:LI30:801:EACT.PROC PP")
    field(LNK3, "QUAD:LI30:801:EERR.DISA PP")
    field(LNK4, "QUAD:LI30:801:ECON.PROC PP")
    field(LNK5, "QUAD:LI30:801:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI30:801:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI30:801:BLEM.PROC PP")
    field(LNK8, "QUAD:LI30:801:BMOD.PROC PP")
    field(LNK9, "QUAD:LI30:801:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI30:801:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI30:801:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI30:801:BMAX")
  field(DOL2, "QUAD:LI30:801:BMAX")
  field(DOL3, "QUAD:LI30:801:BMAX")
  field(DOL4, "QUAD:LI30:801:BMIN")
  field(DOL5, "QUAD:LI30:801:BMIN")
  field(DOL6, "QUAD:LI30:801:BMIN")
  field(LNK1, "QUAD:LI30:801:BMAGX.HOPR")
  field(LNK2, "QUAD:LI30:801:BMAGY.HOPR")
  field(LNK3, "QUAD:LI30:801:BLEM.HOPR")
  field(LNK4, "QUAD:LI30:801:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI30:801:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI30:801:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI30:801:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI30:801:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI30:801:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI30:801:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI30:801:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:801:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:801:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI30:801:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI30:801:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LI30:801:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI30:801:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI30:801:EDES NPP MS")
  field(INPB, "QUAD:LI30:801:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI30:202:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI30:202:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI30:202:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI30:202:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI30:202:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI30:202:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI30:202:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI30:202:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI30:202:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI30:202:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI30:202:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI30:202:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI30:202:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI30:202:EDES.PROC PP")
    field(LNK2, "XCOR:LI30:202:EACT.PROC PP")
    field(LNK3, "XCOR:LI30:202:EERR.DISA PP")
    field(LNK4, "XCOR:LI30:202:ECON.PROC PP")
    field(LNK5, "XCOR:LI30:202:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI30:202:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI30:202:BLEM.PROC PP")
    field(LNK8, "XCOR:LI30:202:BMOD.PROC PP")
    field(LNK9, "XCOR:LI30:202:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI30:202:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI30:202:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI30:202:BMAX")
  field(DOL2, "XCOR:LI30:202:BMAX")
  field(DOL3, "XCOR:LI30:202:BMAX")
  field(DOL4, "XCOR:LI30:202:BMIN")
  field(DOL5, "XCOR:LI30:202:BMIN")
  field(DOL6, "XCOR:LI30:202:BMIN")
  field(LNK1, "XCOR:LI30:202:BMAGX.HOPR")
  field(LNK2, "XCOR:LI30:202:BMAGY.HOPR")
  field(LNK3, "XCOR:LI30:202:BLEM.HOPR")
  field(LNK4, "XCOR:LI30:202:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI30:202:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI30:202:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:202:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:202:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI30:202:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI30:202:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI30:202:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:202:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:202:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:202:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:202:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:202:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI30:202:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI30:202:EDES NPP MS")
  field(INPB, "XCOR:LI30:202:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI30:302:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI30:302:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI30:302:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI30:302:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI30:302:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI30:302:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI30:302:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI30:302:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI30:302:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI30:302:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI30:302:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI30:302:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI30:302:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI30:302:EDES.PROC PP")
    field(LNK2, "XCOR:LI30:302:EACT.PROC PP")
    field(LNK3, "XCOR:LI30:302:EERR.DISA PP")
    field(LNK4, "XCOR:LI30:302:ECON.PROC PP")
    field(LNK5, "XCOR:LI30:302:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI30:302:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI30:302:BLEM.PROC PP")
    field(LNK8, "XCOR:LI30:302:BMOD.PROC PP")
    field(LNK9, "XCOR:LI30:302:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI30:302:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI30:302:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI30:302:BMAX")
  field(DOL2, "XCOR:LI30:302:BMAX")
  field(DOL3, "XCOR:LI30:302:BMAX")
  field(DOL4, "XCOR:LI30:302:BMIN")
  field(DOL5, "XCOR:LI30:302:BMIN")
  field(DOL6, "XCOR:LI30:302:BMIN")
  field(LNK1, "XCOR:LI30:302:BMAGX.HOPR")
  field(LNK2, "XCOR:LI30:302:BMAGY.HOPR")
  field(LNK3, "XCOR:LI30:302:BLEM.HOPR")
  field(LNK4, "XCOR:LI30:302:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI30:302:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI30:302:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:302:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:302:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI30:302:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI30:302:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI30:302:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:302:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:302:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:302:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:302:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:302:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI30:302:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI30:302:EDES NPP MS")
  field(INPB, "XCOR:LI30:302:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI30:402:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI30:402:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI30:402:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI30:402:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI30:402:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI30:402:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI30:402:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI30:402:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI30:402:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI30:402:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI30:402:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI30:402:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI30:402:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI30:402:EDES.PROC PP")
    field(LNK2, "XCOR:LI30:402:EACT.PROC PP")
    field(LNK3, "XCOR:LI30:402:EERR.DISA PP")
    field(LNK4, "XCOR:LI30:402:ECON.PROC PP")
    field(LNK5, "XCOR:LI30:402:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI30:402:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI30:402:BLEM.PROC PP")
    field(LNK8, "XCOR:LI30:402:BMOD.PROC PP")
    field(LNK9, "XCOR:LI30:402:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI30:402:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI30:402:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI30:402:BMAX")
  field(DOL2, "XCOR:LI30:402:BMAX")
  field(DOL3, "XCOR:LI30:402:BMAX")
  field(DOL4, "XCOR:LI30:402:BMIN")
  field(DOL5, "XCOR:LI30:402:BMIN")
  field(DOL6, "XCOR:LI30:402:BMIN")
  field(LNK1, "XCOR:LI30:402:BMAGX.HOPR")
  field(LNK2, "XCOR:LI30:402:BMAGY.HOPR")
  field(LNK3, "XCOR:LI30:402:BLEM.HOPR")
  field(LNK4, "XCOR:LI30:402:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI30:402:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI30:402:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:402:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:402:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI30:402:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI30:402:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI30:402:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:402:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:402:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:402:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:402:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:402:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI30:402:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI30:402:EDES NPP MS")
  field(INPB, "XCOR:LI30:402:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI30:502:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI30:502:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI30:502:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI30:502:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI30:502:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI30:502:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI30:502:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI30:502:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI30:502:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI30:502:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI30:502:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI30:502:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI30:502:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI30:502:EDES.PROC PP")
    field(LNK2, "XCOR:LI30:502:EACT.PROC PP")
    field(LNK3, "XCOR:LI30:502:EERR.DISA PP")
    field(LNK4, "XCOR:LI30:502:ECON.PROC PP")
    field(LNK5, "XCOR:LI30:502:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI30:502:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI30:502:BLEM.PROC PP")
    field(LNK8, "XCOR:LI30:502:BMOD.PROC PP")
    field(LNK9, "XCOR:LI30:502:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI30:502:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI30:502:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI30:502:BMAX")
  field(DOL2, "XCOR:LI30:502:BMAX")
  field(DOL3, "XCOR:LI30:502:BMAX")
  field(DOL4, "XCOR:LI30:502:BMIN")
  field(DOL5, "XCOR:LI30:502:BMIN")
  field(DOL6, "XCOR:LI30:502:BMIN")
  field(LNK1, "XCOR:LI30:502:BMAGX.HOPR")
  field(LNK2, "XCOR:LI30:502:BMAGY.HOPR")
  field(LNK3, "XCOR:LI30:502:BLEM.HOPR")
  field(LNK4, "XCOR:LI30:502:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI30:502:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI30:502:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:502:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:502:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI30:502:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI30:502:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI30:502:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:502:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:502:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:502:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:502:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:502:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI30:502:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI30:502:EDES NPP MS")
  field(INPB, "XCOR:LI30:502:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI30:602:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI30:602:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI30:602:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI30:602:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI30:602:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI30:602:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI30:602:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI30:602:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI30:602:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI30:602:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI30:602:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI30:602:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI30:602:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI30:602:EDES.PROC PP")
    field(LNK2, "XCOR:LI30:602:EACT.PROC PP")
    field(LNK3, "XCOR:LI30:602:EERR.DISA PP")
    field(LNK4, "XCOR:LI30:602:ECON.PROC PP")
    field(LNK5, "XCOR:LI30:602:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI30:602:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI30:602:BLEM.PROC PP")
    field(LNK8, "XCOR:LI30:602:BMOD.PROC PP")
    field(LNK9, "XCOR:LI30:602:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI30:602:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI30:602:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI30:602:BMAX")
  field(DOL2, "XCOR:LI30:602:BMAX")
  field(DOL3, "XCOR:LI30:602:BMAX")
  field(DOL4, "XCOR:LI30:602:BMIN")
  field(DOL5, "XCOR:LI30:602:BMIN")
  field(DOL6, "XCOR:LI30:602:BMIN")
  field(LNK1, "XCOR:LI30:602:BMAGX.HOPR")
  field(LNK2, "XCOR:LI30:602:BMAGY.HOPR")
  field(LNK3, "XCOR:LI30:602:BLEM.HOPR")
  field(LNK4, "XCOR:LI30:602:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI30:602:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI30:602:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:602:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:602:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI30:602:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI30:602:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI30:602:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:602:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:602:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:602:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:602:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:602:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI30:602:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI30:602:EDES NPP MS")
  field(INPB, "XCOR:LI30:602:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI30:702:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI30:702:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI30:702:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI30:702:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI30:702:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI30:702:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI30:702:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI30:702:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI30:702:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI30:702:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI30:702:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI30:702:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI30:702:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI30:702:EDES.PROC PP")
    field(LNK2, "XCOR:LI30:702:EACT.PROC PP")
    field(LNK3, "XCOR:LI30:702:EERR.DISA PP")
    field(LNK4, "XCOR:LI30:702:ECON.PROC PP")
    field(LNK5, "XCOR:LI30:702:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI30:702:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI30:702:BLEM.PROC PP")
    field(LNK8, "XCOR:LI30:702:BMOD.PROC PP")
    field(LNK9, "XCOR:LI30:702:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI30:702:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI30:702:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI30:702:BMAX")
  field(DOL2, "XCOR:LI30:702:BMAX")
  field(DOL3, "XCOR:LI30:702:BMAX")
  field(DOL4, "XCOR:LI30:702:BMIN")
  field(DOL5, "XCOR:LI30:702:BMIN")
  field(DOL6, "XCOR:LI30:702:BMIN")
  field(LNK1, "XCOR:LI30:702:BMAGX.HOPR")
  field(LNK2, "XCOR:LI30:702:BMAGY.HOPR")
  field(LNK3, "XCOR:LI30:702:BLEM.HOPR")
  field(LNK4, "XCOR:LI30:702:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI30:702:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI30:702:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:702:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:702:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI30:702:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI30:702:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI30:702:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:702:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:702:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:702:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:702:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:702:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI30:702:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI30:702:EDES NPP MS")
  field(INPB, "XCOR:LI30:702:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI30:802:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI30:802:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI30:802:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI30:802:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI30:802:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI30:802:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI30:802:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI30:802:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI30:802:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI30:802:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI30:802:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI30:802:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI30:802:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI30:802:EDES.PROC PP")
    field(LNK2, "XCOR:LI30:802:EACT.PROC PP")
    field(LNK3, "XCOR:LI30:802:EERR.DISA PP")
    field(LNK4, "XCOR:LI30:802:ECON.PROC PP")
    field(LNK5, "XCOR:LI30:802:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI30:802:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI30:802:BLEM.PROC PP")
    field(LNK8, "XCOR:LI30:802:BMOD.PROC PP")
    field(LNK9, "XCOR:LI30:802:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI30:802:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI30:802:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI30:802:BMAX")
  field(DOL2, "XCOR:LI30:802:BMAX")
  field(DOL3, "XCOR:LI30:802:BMAX")
  field(DOL4, "XCOR:LI30:802:BMIN")
  field(DOL5, "XCOR:LI30:802:BMIN")
  field(DOL6, "XCOR:LI30:802:BMIN")
  field(LNK1, "XCOR:LI30:802:BMAGX.HOPR")
  field(LNK2, "XCOR:LI30:802:BMAGY.HOPR")
  field(LNK3, "XCOR:LI30:802:BLEM.HOPR")
  field(LNK4, "XCOR:LI30:802:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI30:802:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI30:802:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:802:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:802:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI30:802:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI30:802:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI30:802:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:802:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:802:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:802:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:802:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:802:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI30:802:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI30:802:EDES NPP MS")
  field(INPB, "XCOR:LI30:802:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LI30:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "XCOR:LI30:900:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LI30:900:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LI30:900:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LI30:900:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LI30:900:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LI30:900:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LI30:900:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LI30:900:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LI30:900:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LI30:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LI30:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LI30:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LI30:900:EDES.PROC PP")
    field(LNK2, "XCOR:LI30:900:EACT.PROC PP")
    field(LNK3, "XCOR:LI30:900:EERR.DISA PP")
    field(LNK4, "XCOR:LI30:900:ECON.PROC PP")
    field(LNK5, "XCOR:LI30:900:BMAGX.PROC PP")
    field(LNK6, "XCOR:LI30:900:BMAGY.PROC PP")
    field(LNK7, "XCOR:LI30:900:BLEM.PROC PP")
    field(LNK8, "XCOR:LI30:900:BMOD.PROC PP")
    field(LNK9, "XCOR:LI30:900:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LI30:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LI30:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LI30:900:BMAX")
  field(DOL2, "XCOR:LI30:900:BMAX")
  field(DOL3, "XCOR:LI30:900:BMAX")
  field(DOL4, "XCOR:LI30:900:BMIN")
  field(DOL5, "XCOR:LI30:900:BMIN")
  field(DOL6, "XCOR:LI30:900:BMIN")
  field(LNK1, "XCOR:LI30:900:BMAGX.HOPR")
  field(LNK2, "XCOR:LI30:900:BMAGY.HOPR")
  field(LNK3, "XCOR:LI30:900:BLEM.HOPR")
  field(LNK4, "XCOR:LI30:900:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LI30:900:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LI30:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LI30:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LI30:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LI30:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LI30:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LI30:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LI30:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LI30:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LI30:900:EDES NPP MS")
  field(INPB, "XCOR:LI30:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI30:203:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI30:203:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI30:203:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI30:203:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI30:203:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI30:203:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI30:203:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI30:203:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI30:203:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI30:203:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI30:203:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI30:203:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI30:203:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI30:203:EDES.PROC PP")
    field(LNK2, "YCOR:LI30:203:EACT.PROC PP")
    field(LNK3, "YCOR:LI30:203:EERR.DISA PP")
    field(LNK4, "YCOR:LI30:203:ECON.PROC PP")
    field(LNK5, "YCOR:LI30:203:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI30:203:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI30:203:BLEM.PROC PP")
    field(LNK8, "YCOR:LI30:203:BMOD.PROC PP")
    field(LNK9, "YCOR:LI30:203:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI30:203:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI30:203:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI30:203:BMAX")
  field(DOL2, "YCOR:LI30:203:BMAX")
  field(DOL3, "YCOR:LI30:203:BMAX")
  field(DOL4, "YCOR:LI30:203:BMIN")
  field(DOL5, "YCOR:LI30:203:BMIN")
  field(DOL6, "YCOR:LI30:203:BMIN")
  field(LNK1, "YCOR:LI30:203:BMAGX.HOPR")
  field(LNK2, "YCOR:LI30:203:BMAGY.HOPR")
  field(LNK3, "YCOR:LI30:203:BLEM.HOPR")
  field(LNK4, "YCOR:LI30:203:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI30:203:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI30:203:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:203:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:203:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI30:203:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI30:203:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI30:203:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:203:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:203:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:203:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:203:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:203:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI30:203:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI30:203:EDES NPP MS")
  field(INPB, "YCOR:LI30:203:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI30:303:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI30:303:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI30:303:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI30:303:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI30:303:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI30:303:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI30:303:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI30:303:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI30:303:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI30:303:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI30:303:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI30:303:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI30:303:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI30:303:EDES.PROC PP")
    field(LNK2, "YCOR:LI30:303:EACT.PROC PP")
    field(LNK3, "YCOR:LI30:303:EERR.DISA PP")
    field(LNK4, "YCOR:LI30:303:ECON.PROC PP")
    field(LNK5, "YCOR:LI30:303:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI30:303:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI30:303:BLEM.PROC PP")
    field(LNK8, "YCOR:LI30:303:BMOD.PROC PP")
    field(LNK9, "YCOR:LI30:303:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI30:303:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI30:303:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI30:303:BMAX")
  field(DOL2, "YCOR:LI30:303:BMAX")
  field(DOL3, "YCOR:LI30:303:BMAX")
  field(DOL4, "YCOR:LI30:303:BMIN")
  field(DOL5, "YCOR:LI30:303:BMIN")
  field(DOL6, "YCOR:LI30:303:BMIN")
  field(LNK1, "YCOR:LI30:303:BMAGX.HOPR")
  field(LNK2, "YCOR:LI30:303:BMAGY.HOPR")
  field(LNK3, "YCOR:LI30:303:BLEM.HOPR")
  field(LNK4, "YCOR:LI30:303:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI30:303:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI30:303:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:303:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:303:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI30:303:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI30:303:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI30:303:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:303:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:303:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:303:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:303:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:303:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI30:303:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI30:303:EDES NPP MS")
  field(INPB, "YCOR:LI30:303:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI30:403:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI30:403:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI30:403:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI30:403:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI30:403:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI30:403:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI30:403:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI30:403:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI30:403:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI30:403:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI30:403:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI30:403:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI30:403:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI30:403:EDES.PROC PP")
    field(LNK2, "YCOR:LI30:403:EACT.PROC PP")
    field(LNK3, "YCOR:LI30:403:EERR.DISA PP")
    field(LNK4, "YCOR:LI30:403:ECON.PROC PP")
    field(LNK5, "YCOR:LI30:403:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI30:403:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI30:403:BLEM.PROC PP")
    field(LNK8, "YCOR:LI30:403:BMOD.PROC PP")
    field(LNK9, "YCOR:LI30:403:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI30:403:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI30:403:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI30:403:BMAX")
  field(DOL2, "YCOR:LI30:403:BMAX")
  field(DOL3, "YCOR:LI30:403:BMAX")
  field(DOL4, "YCOR:LI30:403:BMIN")
  field(DOL5, "YCOR:LI30:403:BMIN")
  field(DOL6, "YCOR:LI30:403:BMIN")
  field(LNK1, "YCOR:LI30:403:BMAGX.HOPR")
  field(LNK2, "YCOR:LI30:403:BMAGY.HOPR")
  field(LNK3, "YCOR:LI30:403:BLEM.HOPR")
  field(LNK4, "YCOR:LI30:403:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI30:403:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI30:403:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:403:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:403:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI30:403:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI30:403:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI30:403:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:403:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:403:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:403:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:403:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:403:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI30:403:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI30:403:EDES NPP MS")
  field(INPB, "YCOR:LI30:403:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI30:503:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI30:503:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI30:503:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI30:503:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI30:503:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI30:503:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI30:503:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI30:503:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI30:503:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI30:503:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI30:503:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI30:503:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI30:503:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI30:503:EDES.PROC PP")
    field(LNK2, "YCOR:LI30:503:EACT.PROC PP")
    field(LNK3, "YCOR:LI30:503:EERR.DISA PP")
    field(LNK4, "YCOR:LI30:503:ECON.PROC PP")
    field(LNK5, "YCOR:LI30:503:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI30:503:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI30:503:BLEM.PROC PP")
    field(LNK8, "YCOR:LI30:503:BMOD.PROC PP")
    field(LNK9, "YCOR:LI30:503:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI30:503:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI30:503:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI30:503:BMAX")
  field(DOL2, "YCOR:LI30:503:BMAX")
  field(DOL3, "YCOR:LI30:503:BMAX")
  field(DOL4, "YCOR:LI30:503:BMIN")
  field(DOL5, "YCOR:LI30:503:BMIN")
  field(DOL6, "YCOR:LI30:503:BMIN")
  field(LNK1, "YCOR:LI30:503:BMAGX.HOPR")
  field(LNK2, "YCOR:LI30:503:BMAGY.HOPR")
  field(LNK3, "YCOR:LI30:503:BLEM.HOPR")
  field(LNK4, "YCOR:LI30:503:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI30:503:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI30:503:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:503:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:503:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI30:503:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI30:503:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI30:503:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:503:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:503:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:503:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:503:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:503:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI30:503:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI30:503:EDES NPP MS")
  field(INPB, "YCOR:LI30:503:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI30:603:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI30:603:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI30:603:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI30:603:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI30:603:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI30:603:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI30:603:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI30:603:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI30:603:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI30:603:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI30:603:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI30:603:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI30:603:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI30:603:EDES.PROC PP")
    field(LNK2, "YCOR:LI30:603:EACT.PROC PP")
    field(LNK3, "YCOR:LI30:603:EERR.DISA PP")
    field(LNK4, "YCOR:LI30:603:ECON.PROC PP")
    field(LNK5, "YCOR:LI30:603:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI30:603:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI30:603:BLEM.PROC PP")
    field(LNK8, "YCOR:LI30:603:BMOD.PROC PP")
    field(LNK9, "YCOR:LI30:603:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI30:603:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI30:603:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI30:603:BMAX")
  field(DOL2, "YCOR:LI30:603:BMAX")
  field(DOL3, "YCOR:LI30:603:BMAX")
  field(DOL4, "YCOR:LI30:603:BMIN")
  field(DOL5, "YCOR:LI30:603:BMIN")
  field(DOL6, "YCOR:LI30:603:BMIN")
  field(LNK1, "YCOR:LI30:603:BMAGX.HOPR")
  field(LNK2, "YCOR:LI30:603:BMAGY.HOPR")
  field(LNK3, "YCOR:LI30:603:BLEM.HOPR")
  field(LNK4, "YCOR:LI30:603:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI30:603:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI30:603:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:603:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:603:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI30:603:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI30:603:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI30:603:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:603:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:603:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:603:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:603:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:603:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI30:603:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI30:603:EDES NPP MS")
  field(INPB, "YCOR:LI30:603:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI30:703:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI30:703:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI30:703:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI30:703:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI30:703:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI30:703:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI30:703:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI30:703:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI30:703:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI30:703:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI30:703:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI30:703:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI30:703:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI30:703:EDES.PROC PP")
    field(LNK2, "YCOR:LI30:703:EACT.PROC PP")
    field(LNK3, "YCOR:LI30:703:EERR.DISA PP")
    field(LNK4, "YCOR:LI30:703:ECON.PROC PP")
    field(LNK5, "YCOR:LI30:703:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI30:703:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI30:703:BLEM.PROC PP")
    field(LNK8, "YCOR:LI30:703:BMOD.PROC PP")
    field(LNK9, "YCOR:LI30:703:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI30:703:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI30:703:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI30:703:BMAX")
  field(DOL2, "YCOR:LI30:703:BMAX")
  field(DOL3, "YCOR:LI30:703:BMAX")
  field(DOL4, "YCOR:LI30:703:BMIN")
  field(DOL5, "YCOR:LI30:703:BMIN")
  field(DOL6, "YCOR:LI30:703:BMIN")
  field(LNK1, "YCOR:LI30:703:BMAGX.HOPR")
  field(LNK2, "YCOR:LI30:703:BMAGY.HOPR")
  field(LNK3, "YCOR:LI30:703:BLEM.HOPR")
  field(LNK4, "YCOR:LI30:703:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI30:703:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI30:703:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:703:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:703:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI30:703:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI30:703:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI30:703:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:703:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:703:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:703:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:703:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:703:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI30:703:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI30:703:EDES NPP MS")
  field(INPB, "YCOR:LI30:703:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI30:803:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI30:803:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI30:803:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI30:803:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI30:803:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI30:803:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI30:803:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI30:803:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI30:803:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI30:803:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI30:803:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI30:803:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI30:803:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI30:803:EDES.PROC PP")
    field(LNK2, "YCOR:LI30:803:EACT.PROC PP")
    field(LNK3, "YCOR:LI30:803:EERR.DISA PP")
    field(LNK4, "YCOR:LI30:803:ECON.PROC PP")
    field(LNK5, "YCOR:LI30:803:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI30:803:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI30:803:BLEM.PROC PP")
    field(LNK8, "YCOR:LI30:803:BMOD.PROC PP")
    field(LNK9, "YCOR:LI30:803:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI30:803:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI30:803:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI30:803:BMAX")
  field(DOL2, "YCOR:LI30:803:BMAX")
  field(DOL3, "YCOR:LI30:803:BMAX")
  field(DOL4, "YCOR:LI30:803:BMIN")
  field(DOL5, "YCOR:LI30:803:BMIN")
  field(DOL6, "YCOR:LI30:803:BMIN")
  field(LNK1, "YCOR:LI30:803:BMAGX.HOPR")
  field(LNK2, "YCOR:LI30:803:BMAGY.HOPR")
  field(LNK3, "YCOR:LI30:803:BLEM.HOPR")
  field(LNK4, "YCOR:LI30:803:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI30:803:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI30:803:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:803:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:803:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI30:803:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI30:803:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI30:803:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:803:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:803:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:803:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:803:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:803:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI30:803:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI30:803:EDES NPP MS")
  field(INPB, "YCOR:LI30:803:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LI30:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI30:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI30:1:CTRL.RVAL")
  field(LNK1, "YCOR:LI30:900:FUNC CA PP")
  field(DOL2, "MGNT:LI30:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LI30:900:FUNC CA PP")
  field(DOL3, "MGNT:LI30:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LI30:900:FUNC CA PP")
  field(DOL4, "MGNT:LI30:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LI30:900:FUNC CA PP")
  field(DOL5, "MGNT:LI30:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LI30:900:FUNC CA PP")
  field(DOL6, "MGNT:LI30:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LI30:900:FUNC CA PP")
  field(DOL7, "MGNT:LI30:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LI30:900:FUNC CA PP")
  field(DOL8, "MGNT:LI30:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LI30:900:FUNC CA PP")
  field(DOL9, "MGNT:LI30:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LI30:900:FUNC CA PP")
  field(DOLA, "MGNT:LI30:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LI30:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LI30:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LI30:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LI30:900:EDES.PROC PP")
    field(LNK2, "YCOR:LI30:900:EACT.PROC PP")
    field(LNK3, "YCOR:LI30:900:EERR.DISA PP")
    field(LNK4, "YCOR:LI30:900:ECON.PROC PP")
    field(LNK5, "YCOR:LI30:900:BMAGX.PROC PP")
    field(LNK6, "YCOR:LI30:900:BMAGY.PROC PP")
    field(LNK7, "YCOR:LI30:900:BLEM.PROC PP")
    field(LNK8, "YCOR:LI30:900:BMOD.PROC PP")
    field(LNK9, "YCOR:LI30:900:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LI30:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LI30:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LI30:900:BMAX")
  field(DOL2, "YCOR:LI30:900:BMAX")
  field(DOL3, "YCOR:LI30:900:BMAX")
  field(DOL4, "YCOR:LI30:900:BMIN")
  field(DOL5, "YCOR:LI30:900:BMIN")
  field(DOL6, "YCOR:LI30:900:BMIN")
  field(LNK1, "YCOR:LI30:900:BMAGX.HOPR")
  field(LNK2, "YCOR:LI30:900:BMAGY.HOPR")
  field(LNK3, "YCOR:LI30:900:BLEM.HOPR")
  field(LNK4, "YCOR:LI30:900:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LI30:900:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LI30:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LI30:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LI30:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LI30:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LI30:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LI30:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LI30:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LI30:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LI30:900:EDES NPP MS")
  field(INPB, "YCOR:LI30:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LI21:215:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "BEND:LI21:215:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LI21:215:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LI21:215:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LI21:215:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LI21:215:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LI21:215:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LI21:215:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LI21:215:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LI21:215:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LI21:215:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LI21:215:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LI21:215:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LI21:215:EDES.PROC PP")
    field(LNK2, "BEND:LI21:215:EACT.PROC PP")
    field(LNK3, "BEND:LI21:215:EERR.DISA PP")
    field(LNK4, "BEND:LI21:215:ECON.PROC PP")
    field(LNK5, "BEND:LI21:215:BMAGX.PROC PP")
    field(LNK6, "BEND:LI21:215:BMAGY.PROC PP")
    field(LNK7, "BEND:LI21:215:BLEM.PROC PP")
    field(LNK8, "BEND:LI21:215:BMOD.PROC PP")
    field(LNK9, "BEND:LI21:215:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LI21:215:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LI21:215:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LI21:215:BMAX")
  field(DOL2, "BEND:LI21:215:BMAX")
  field(DOL3, "BEND:LI21:215:BMAX")
  field(DOL4, "BEND:LI21:215:BMIN")
  field(DOL5, "BEND:LI21:215:BMIN")
  field(DOL6, "BEND:LI21:215:BMIN")
  field(LNK1, "BEND:LI21:215:BMAGX.HOPR")
  field(LNK2, "BEND:LI21:215:BMAGY.HOPR")
  field(LNK3, "BEND:LI21:215:BLEM.HOPR")
  field(LNK4, "BEND:LI21:215:BMAGX.LOPR PP")
  field(LNK5, "BEND:LI21:215:BMAGY.LOPR PP")
  field(LNK6, "BEND:LI21:215:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LI21:215:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LI21:215:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LI21:215:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LI21:215:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LI21:215:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI21:215:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LI21:231:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI21:215:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LI21:231:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LI21:215:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI21:215:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LI21:231:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LI21:215:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LI21:215:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LI21:215:EDES NPP MS")
  field(INPB, "BEND:LI21:215:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LI21:241:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "BEND:LI21:241:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LI21:241:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LI21:241:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LI21:241:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LI21:241:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LI21:241:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LI21:241:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LI21:241:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LI21:241:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LI21:241:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LI21:241:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LI21:241:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LI21:241:EDES.PROC PP")
    field(LNK2, "BEND:LI21:241:EACT.PROC PP")
    field(LNK3, "BEND:LI21:241:EERR.DISA PP")
    field(LNK4, "BEND:LI21:241:ECON.PROC PP")
    field(LNK5, "BEND:LI21:241:BMAGX.PROC PP")
    field(LNK6, "BEND:LI21:241:BMAGY.PROC PP")
    field(LNK7, "BEND:LI21:241:BLEM.PROC PP")
    field(LNK8, "BEND:LI21:241:BMOD.PROC PP")
    field(LNK9, "BEND:LI21:241:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LI21:241:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LI21:241:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LI21:241:BMAX")
  field(DOL2, "BEND:LI21:241:BMAX")
  field(DOL3, "BEND:LI21:241:BMAX")
  field(DOL4, "BEND:LI21:241:BMIN")
  field(DOL5, "BEND:LI21:241:BMIN")
  field(DOL6, "BEND:LI21:241:BMIN")
  field(LNK1, "BEND:LI21:241:BMAGX.HOPR")
  field(LNK2, "BEND:LI21:241:BMAGY.HOPR")
  field(LNK3, "BEND:LI21:241:BLEM.HOPR")
  field(LNK4, "BEND:LI21:241:BMAGX.LOPR PP")
  field(LNK5, "BEND:LI21:241:BMAGY.LOPR PP")
  field(LNK6, "BEND:LI21:241:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LI21:241:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LI21:241:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LI21:241:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LI21:241:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LI21:241:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI21:241:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LI21:231:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI21:241:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LI21:231:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LI21:241:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI21:241:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LI21:231:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LI21:241:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LI21:241:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LI21:241:EDES NPP MS")
  field(INPB, "BEND:LI21:241:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LI21:261:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI21:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI21:1:CTRL.RVAL")
  field(LNK1, "BEND:LI21:261:FUNC CA PP")
  field(DOL2, "MGNT:LI21:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LI21:261:FUNC CA PP")
  field(DOL3, "MGNT:LI21:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LI21:261:FUNC CA PP")
  field(DOL4, "MGNT:LI21:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LI21:261:FUNC CA PP")
  field(DOL5, "MGNT:LI21:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LI21:261:FUNC CA PP")
  field(DOL6, "MGNT:LI21:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LI21:261:FUNC CA PP")
  field(DOL7, "MGNT:LI21:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LI21:261:FUNC CA PP")
  field(DOL8, "MGNT:LI21:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LI21:261:FUNC CA PP")
  field(DOL9, "MGNT:LI21:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LI21:261:FUNC CA PP")
  field(DOLA, "MGNT:LI21:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LI21:261:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LI21:261:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LI21:261:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LI21:261:EDES.PROC PP")
    field(LNK2, "BEND:LI21:261:EACT.PROC PP")
    field(LNK3, "BEND:LI21:261:EERR.DISA PP")
    field(LNK4, "BEND:LI21:261:ECON.PROC PP")
    field(LNK5, "BEND:LI21:261:BMAGX.PROC PP")
    field(LNK6, "BEND:LI21:261:BMAGY.PROC PP")
    field(LNK7, "BEND:LI21:261:BLEM.PROC PP")
    field(LNK8, "BEND:LI21:261:BMOD.PROC PP")
    field(LNK9, "BEND:LI21:261:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LI21:261:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LI21:261:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LI21:261:BMAX")
  field(DOL2, "BEND:LI21:261:BMAX")
  field(DOL3, "BEND:LI21:261:BMAX")
  field(DOL4, "BEND:LI21:261:BMIN")
  field(DOL5, "BEND:LI21:261:BMIN")
  field(DOL6, "BEND:LI21:261:BMIN")
  field(LNK1, "BEND:LI21:261:BMAGX.HOPR")
  field(LNK2, "BEND:LI21:261:BMAGY.HOPR")
  field(LNK3, "BEND:LI21:261:BLEM.HOPR")
  field(LNK4, "BEND:LI21:261:BMAGX.LOPR PP")
  field(LNK5, "BEND:LI21:261:BMAGY.LOPR PP")
  field(LNK6, "BEND:LI21:261:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LI21:261:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LI21:261:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LI21:261:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LI21:261:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LI21:261:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI21:261:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LI21:231:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI21:261:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LI21:231:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LI21:261:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI21:261:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LI21:231:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LI21:261:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LI21:261:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LI21:261:EDES NPP MS")
  field(INPB, "BEND:LI21:261:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI24:702:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI24:702:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI24:702:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI24:702:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI24:702:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI24:702:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI24:702:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI24:702:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI24:702:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI24:702:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI24:702:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI24:702:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI24:702:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI24:702:EDES.PROC PP")
    field(LNK2, "QUAD:LI24:702:EACT.PROC PP")
    field(LNK3, "QUAD:LI24:702:EERR.DISA PP")
    field(LNK4, "QUAD:LI24:702:ECON.PROC PP")
    field(LNK5, "QUAD:LI24:702:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI24:702:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI24:702:BLEM.PROC PP")
    field(LNK8, "QUAD:LI24:702:BMOD.PROC PP")
    field(LNK9, "QUAD:LI24:702:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI24:702:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI24:702:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI24:702:BMAX")
  field(DOL2, "QUAD:LI24:702:BMAX")
  field(DOL3, "QUAD:LI24:702:BMAX")
  field(DOL4, "QUAD:LI24:702:BMIN")
  field(DOL5, "QUAD:LI24:702:BMIN")
  field(DOL6, "QUAD:LI24:702:BMIN")
  field(LNK1, "QUAD:LI24:702:BMAGX.HOPR")
  field(LNK2, "QUAD:LI24:702:BMAGY.HOPR")
  field(LNK3, "QUAD:LI24:702:BLEM.HOPR")
  field(LNK4, "QUAD:LI24:702:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI24:702:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI24:702:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:702:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:702:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI24:702:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI24:702:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI24:702:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:702:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LI24:701:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:702:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LI24:701:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LI24:702:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:702:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LI24:701:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LI24:702:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI24:702:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI24:702:EDES NPP MS")
  field(INPB, "QUAD:LI24:702:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LI24:720:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "BEND:LI24:720:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LI24:720:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LI24:720:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LI24:720:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LI24:720:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LI24:720:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LI24:720:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LI24:720:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LI24:720:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LI24:720:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LI24:720:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LI24:720:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LI24:720:EDES.PROC PP")
    field(LNK2, "BEND:LI24:720:EACT.PROC PP")
    field(LNK3, "BEND:LI24:720:EERR.DISA PP")
    field(LNK4, "BEND:LI24:720:ECON.PROC PP")
    field(LNK5, "BEND:LI24:720:BMAGX.PROC PP")
    field(LNK6, "BEND:LI24:720:BMAGY.PROC PP")
    field(LNK7, "BEND:LI24:720:BLEM.PROC PP")
    field(LNK8, "BEND:LI24:720:BMOD.PROC PP")
    field(LNK9, "BEND:LI24:720:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LI24:720:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LI24:720:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LI24:720:BMAX")
  field(DOL2, "BEND:LI24:720:BMAX")
  field(DOL3, "BEND:LI24:720:BMAX")
  field(DOL4, "BEND:LI24:720:BMIN")
  field(DOL5, "BEND:LI24:720:BMIN")
  field(DOL6, "BEND:LI24:720:BMIN")
  field(LNK1, "BEND:LI24:720:BMAGX.HOPR")
  field(LNK2, "BEND:LI24:720:BMAGY.HOPR")
  field(LNK3, "BEND:LI24:720:BLEM.HOPR")
  field(LNK4, "BEND:LI24:720:BMAGX.LOPR PP")
  field(LNK5, "BEND:LI24:720:BMAGY.LOPR PP")
  field(LNK6, "BEND:LI24:720:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LI24:720:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LI24:720:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LI24:720:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LI24:720:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LI24:720:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI24:720:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LI24:790:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI24:720:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LI24:790:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LI24:720:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI24:720:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LI24:790:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LI24:720:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LI24:720:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LI24:720:EDES NPP MS")
  field(INPB, "BEND:LI24:720:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LI24:810:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "BEND:LI24:810:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LI24:810:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LI24:810:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LI24:810:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LI24:810:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LI24:810:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LI24:810:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LI24:810:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LI24:810:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LI24:810:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LI24:810:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LI24:810:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LI24:810:EDES.PROC PP")
    field(LNK2, "BEND:LI24:810:EACT.PROC PP")
    field(LNK3, "BEND:LI24:810:EERR.DISA PP")
    field(LNK4, "BEND:LI24:810:ECON.PROC PP")
    field(LNK5, "BEND:LI24:810:BMAGX.PROC PP")
    field(LNK6, "BEND:LI24:810:BMAGY.PROC PP")
    field(LNK7, "BEND:LI24:810:BLEM.PROC PP")
    field(LNK8, "BEND:LI24:810:BMOD.PROC PP")
    field(LNK9, "BEND:LI24:810:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LI24:810:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LI24:810:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LI24:810:BMAX")
  field(DOL2, "BEND:LI24:810:BMAX")
  field(DOL3, "BEND:LI24:810:BMAX")
  field(DOL4, "BEND:LI24:810:BMIN")
  field(DOL5, "BEND:LI24:810:BMIN")
  field(DOL6, "BEND:LI24:810:BMIN")
  field(LNK1, "BEND:LI24:810:BMAGX.HOPR")
  field(LNK2, "BEND:LI24:810:BMAGY.HOPR")
  field(LNK3, "BEND:LI24:810:BLEM.HOPR")
  field(LNK4, "BEND:LI24:810:BMAGX.LOPR PP")
  field(LNK5, "BEND:LI24:810:BMAGY.LOPR PP")
  field(LNK6, "BEND:LI24:810:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LI24:810:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LI24:810:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LI24:810:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LI24:810:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LI24:810:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI24:810:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LI24:790:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI24:810:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LI24:790:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LI24:810:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI24:810:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LI24:790:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LI24:810:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LI24:810:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LI24:810:EDES NPP MS")
  field(INPB, "BEND:LI24:810:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LI24:880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "BEND:LI24:880:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LI24:880:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LI24:880:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LI24:880:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LI24:880:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LI24:880:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LI24:880:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LI24:880:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LI24:880:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LI24:880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LI24:880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LI24:880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LI24:880:EDES.PROC PP")
    field(LNK2, "BEND:LI24:880:EACT.PROC PP")
    field(LNK3, "BEND:LI24:880:EERR.DISA PP")
    field(LNK4, "BEND:LI24:880:ECON.PROC PP")
    field(LNK5, "BEND:LI24:880:BMAGX.PROC PP")
    field(LNK6, "BEND:LI24:880:BMAGY.PROC PP")
    field(LNK7, "BEND:LI24:880:BLEM.PROC PP")
    field(LNK8, "BEND:LI24:880:BMOD.PROC PP")
    field(LNK9, "BEND:LI24:880:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LI24:880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LI24:880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LI24:880:BMAX")
  field(DOL2, "BEND:LI24:880:BMAX")
  field(DOL3, "BEND:LI24:880:BMAX")
  field(DOL4, "BEND:LI24:880:BMIN")
  field(DOL5, "BEND:LI24:880:BMIN")
  field(DOL6, "BEND:LI24:880:BMIN")
  field(LNK1, "BEND:LI24:880:BMAGX.HOPR")
  field(LNK2, "BEND:LI24:880:BMAGY.HOPR")
  field(LNK3, "BEND:LI24:880:BLEM.HOPR")
  field(LNK4, "BEND:LI24:880:BMAGX.LOPR PP")
  field(LNK5, "BEND:LI24:880:BMAGY.LOPR PP")
  field(LNK6, "BEND:LI24:880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LI24:880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LI24:880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LI24:880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LI24:880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LI24:880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI24:880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LI24:790:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI24:880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LI24:790:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LI24:880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LI24:880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LI24:790:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LI24:880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LI24:880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LI24:880:EDES NPP MS")
  field(INPB, "BEND:LI24:880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LI24:902:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LI24:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LI24:1:CTRL.RVAL")
  field(LNK1, "QUAD:LI24:902:FUNC CA PP")
  field(DOL2, "MGNT:LI24:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LI24:902:FUNC CA PP")
  field(DOL3, "MGNT:LI24:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LI24:902:FUNC CA PP")
  field(DOL4, "MGNT:LI24:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LI24:902:FUNC CA PP")
  field(DOL5, "MGNT:LI24:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LI24:902:FUNC CA PP")
  field(DOL6, "MGNT:LI24:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LI24:902:FUNC CA PP")
  field(DOL7, "MGNT:LI24:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LI24:902:FUNC CA PP")
  field(DOL8, "MGNT:LI24:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LI24:902:FUNC CA PP")
  field(DOL9, "MGNT:LI24:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LI24:902:FUNC CA PP")
  field(DOLA, "MGNT:LI24:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LI24:902:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LI24:902:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LI24:902:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LI24:902:EDES.PROC PP")
    field(LNK2, "QUAD:LI24:902:EACT.PROC PP")
    field(LNK3, "QUAD:LI24:902:EERR.DISA PP")
    field(LNK4, "QUAD:LI24:902:ECON.PROC PP")
    field(LNK5, "QUAD:LI24:902:BMAGX.PROC PP")
    field(LNK6, "QUAD:LI24:902:BMAGY.PROC PP")
    field(LNK7, "QUAD:LI24:902:BLEM.PROC PP")
    field(LNK8, "QUAD:LI24:902:BMOD.PROC PP")
    field(LNK9, "QUAD:LI24:902:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LI24:902:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LI24:902:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LI24:902:BMAX")
  field(DOL2, "QUAD:LI24:902:BMAX")
  field(DOL3, "QUAD:LI24:902:BMAX")
  field(DOL4, "QUAD:LI24:902:BMIN")
  field(DOL5, "QUAD:LI24:902:BMIN")
  field(DOL6, "QUAD:LI24:902:BMIN")
  field(LNK1, "QUAD:LI24:902:BMAGX.HOPR")
  field(LNK2, "QUAD:LI24:902:BMAGY.HOPR")
  field(LNK3, "QUAD:LI24:902:BLEM.HOPR")
  field(LNK4, "QUAD:LI24:902:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LI24:902:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LI24:902:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:902:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LI24:902:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LI24:902:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LI24:902:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LI24:902:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:902:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LI24:901:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:902:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LI24:901:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LI24:902:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LI24:902:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LI24:901:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LI24:902:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LI24:902:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LI24:902:EDES NPP MS")
  field(INPB, "QUAD:LI24:902:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:BSY0:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:BSY0:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:BSY0:1:CTRL CA PP")
  field(LNK2, "MGNT:BSY0:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:BSY0:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:BSY0:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:BSY0:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:BSY0:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:BSY0:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:BSY0:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:BSY0:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:BSY0:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:BSY0:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:BSY0:1:ALLSWITCH")
}

record(seq, "MGNT:BSY0:1:ALLSWITCH") {
  field(DOL1, "MGNT:BSY0:1:CTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:CTRL")
}

record(bo, "MGNT:BSY0:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:BSY0:1:ALLSTARGO")
}

record(fanout, "MGNT:BSY0:1:ALLSTARGO") {
  field(LNK1, "MGNT:BSY0:1:ALLBENDSGO")
  field(LNK2, "MGNT:BSY0:1:ALLBTRMSGO")
  field(LNK3, "MGNT:BSY0:1:ALLLGPSSGO")
  field(LNK4, "MGNT:BSY0:1:ALLQUADSGO")
  field(LNK5, "MGNT:BSY0:1:ALLXCORSGO")
  field(LNK6, "MGNT:BSY0:1:ALLYCORSGO")
  field(FLNK, "MGNT:BSY0:1:ALLSTARGO_2")
}
record(fanout, "MGNT:BSY0:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:BSY0:1:ALLSOLNSGO")
  field(LNK2, "MGNT:BSY0:1:ALLKICKSGO")
  field(LNK3, "MGNT:BSY0:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:BSY0:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:BSY0:1:BENDSWITCH")
}

record(seq, "MGNT:BSY0:1:BENDSWITCH") {
  field(DOL1, "MGNT:BSY0:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:BENDCTRL")
}

record(seq, "MGNT:BSY0:1:ALLBENDSGO") {
  field(DOL1, "MGNT:BSY0:1:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:BSY0:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:BENDCTRL",20,10,0,0,"MGNT:BSY0:1:BENDCTRL")
#! Field("MGNT:BSY0:1:BENDCTRL.FLNK",16777215,1,"MGNT:BSY0:1:BENDCTRL.FLNK")
#! Link("MGNT:BSY0:1:BENDCTRL.FLNK","MGNT:BSY0:1:BENDSWITCH")
#! Field("MGNT:BSY0:1:BENDCTRL.FFVL",16777215,1,"MGNT:BSY0:1:BENDCTRL.FFVL")
#! Record("MGNT:BSY0:1:BENDSWITCH",460,322,0,0,"MGNT:BSY0:1:BENDSWITCH")
#! Field("MGNT:BSY0:1:BENDSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:BENDSWITCH.DOL1")
#! Link("MGNT:BSY0:1:BENDSWITCH.DOL1","MGNT:BSY0:1:BENDCTRL.FFVL")
#! Field("MGNT:BSY0:1:BENDSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:BENDSWITCH.LNK1")
#! Field("MGNT:BSY0:1:BENDSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:BENDSWITCH.FLNK")
#! Record("MGNT:BSY0:1:ALLBENDSGO",240,96,0,0,"MGNT:BSY0:1:ALLBENDSGO")
#! Field("MGNT:BSY0:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:BSY0:1:ALLBENDSGO.DOL1")
#! Field("MGNT:BSY0:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:BSY0:1:ALLBENDSGO.LNK1")
#! Link("MGNT:BSY0:1:ALLBENDSGO.LNK1","MGNT:BSY0:1:ALLBENDS.VAL")
#! Record("MGNT:BSY0:1:ALLBENDS",540,102,0,0,"MGNT:BSY0:1:ALLBENDS")
#! Field("MGNT:BSY0:1:ALLBENDS.VAL",16777215,0,"MGNT:BSY0:1:ALLBENDS.VAL")
#! Field("MGNT:BSY0:1:ALLBENDS.FLNK",16777215,1,"MGNT:BSY0:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:BSY0:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:BSY0:1:BTRMSWITCH")
}

record(seq, "MGNT:BSY0:1:BTRMSWITCH") {
  field(DOL1, "MGNT:BSY0:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:BTRMCTRL")
}

record(seq, "MGNT:BSY0:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:BSY0:1:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:BSY0:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:BTRMCTRL",20,10,0,0,"MGNT:BSY0:1:BTRMCTRL")
#! Field("MGNT:BSY0:1:BTRMCTRL.FLNK",16777215,1,"MGNT:BSY0:1:BTRMCTRL.FLNK")
#! Link("MGNT:BSY0:1:BTRMCTRL.FLNK","MGNT:BSY0:1:BTRMSWITCH")
#! Field("MGNT:BSY0:1:BTRMCTRL.FFVL",16777215,1,"MGNT:BSY0:1:BTRMCTRL.FFVL")
#! Record("MGNT:BSY0:1:BTRMSWITCH",460,322,0,0,"MGNT:BSY0:1:BTRMSWITCH")
#! Field("MGNT:BSY0:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:BTRMSWITCH.DOL1")
#! Link("MGNT:BSY0:1:BTRMSWITCH.DOL1","MGNT:BSY0:1:BTRMCTRL.FFVL")
#! Field("MGNT:BSY0:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:BTRMSWITCH.LNK1")
#! Field("MGNT:BSY0:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:BTRMSWITCH.FLNK")
#! Record("MGNT:BSY0:1:ALLBTRMSGO",240,96,0,0,"MGNT:BSY0:1:ALLBTRMSGO")
#! Field("MGNT:BSY0:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:BSY0:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:BSY0:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:BSY0:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:BSY0:1:ALLBTRMSGO.LNK1","MGNT:BSY0:1:ALLBTRMS.VAL")
#! Record("MGNT:BSY0:1:ALLBTRMS",540,102,0,0,"MGNT:BSY0:1:ALLBTRMS")
#! Field("MGNT:BSY0:1:ALLBTRMS.VAL",16777215,0,"MGNT:BSY0:1:ALLBTRMS.VAL")
#! Field("MGNT:BSY0:1:ALLBTRMS.FLNK",16777215,1,"MGNT:BSY0:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:BSY0:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:BSY0:1:LGPSSWITCH")
}

record(seq, "MGNT:BSY0:1:LGPSSWITCH") {
  field(DOL1, "MGNT:BSY0:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:LGPSCTRL")
}

record(seq, "MGNT:BSY0:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:BSY0:1:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:BSY0:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:LGPSCTRL",20,10,0,0,"MGNT:BSY0:1:LGPSCTRL")
#! Field("MGNT:BSY0:1:LGPSCTRL.FLNK",16777215,1,"MGNT:BSY0:1:LGPSCTRL.FLNK")
#! Link("MGNT:BSY0:1:LGPSCTRL.FLNK","MGNT:BSY0:1:LGPSSWITCH")
#! Field("MGNT:BSY0:1:LGPSCTRL.FFVL",16777215,1,"MGNT:BSY0:1:LGPSCTRL.FFVL")
#! Record("MGNT:BSY0:1:LGPSSWITCH",460,322,0,0,"MGNT:BSY0:1:LGPSSWITCH")
#! Field("MGNT:BSY0:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:LGPSSWITCH.DOL1")
#! Link("MGNT:BSY0:1:LGPSSWITCH.DOL1","MGNT:BSY0:1:LGPSCTRL.FFVL")
#! Field("MGNT:BSY0:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:LGPSSWITCH.LNK1")
#! Field("MGNT:BSY0:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:LGPSSWITCH.FLNK")
#! Record("MGNT:BSY0:1:ALLLGPSSGO",240,96,0,0,"MGNT:BSY0:1:ALLLGPSSGO")
#! Field("MGNT:BSY0:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:BSY0:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:BSY0:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:BSY0:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:BSY0:1:ALLLGPSSGO.LNK1","MGNT:BSY0:1:ALLLGPSS.VAL")
#! Record("MGNT:BSY0:1:ALLLGPSS",540,102,0,0,"MGNT:BSY0:1:ALLLGPSS")
#! Field("MGNT:BSY0:1:ALLLGPSS.VAL",16777215,0,"MGNT:BSY0:1:ALLLGPSS.VAL")
#! Field("MGNT:BSY0:1:ALLLGPSS.FLNK",16777215,1,"MGNT:BSY0:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:BSY0:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:BSY0:1:QUADSWITCH")
}

record(seq, "MGNT:BSY0:1:QUADSWITCH") {
  field(DOL1, "MGNT:BSY0:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:QUADCTRL")
}

record(seq, "MGNT:BSY0:1:ALLQUADSGO") {
  field(DOL1, "MGNT:BSY0:1:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:BSY0:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:QUADCTRL",20,10,0,0,"MGNT:BSY0:1:QUADCTRL")
#! Field("MGNT:BSY0:1:QUADCTRL.FLNK",16777215,1,"MGNT:BSY0:1:QUADCTRL.FLNK")
#! Link("MGNT:BSY0:1:QUADCTRL.FLNK","MGNT:BSY0:1:QUADSWITCH")
#! Field("MGNT:BSY0:1:QUADCTRL.FFVL",16777215,1,"MGNT:BSY0:1:QUADCTRL.FFVL")
#! Record("MGNT:BSY0:1:QUADSWITCH",460,322,0,0,"MGNT:BSY0:1:QUADSWITCH")
#! Field("MGNT:BSY0:1:QUADSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:QUADSWITCH.DOL1")
#! Link("MGNT:BSY0:1:QUADSWITCH.DOL1","MGNT:BSY0:1:QUADCTRL.FFVL")
#! Field("MGNT:BSY0:1:QUADSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:QUADSWITCH.LNK1")
#! Field("MGNT:BSY0:1:QUADSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:QUADSWITCH.FLNK")
#! Record("MGNT:BSY0:1:ALLQUADSGO",240,96,0,0,"MGNT:BSY0:1:ALLQUADSGO")
#! Field("MGNT:BSY0:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:BSY0:1:ALLQUADSGO.DOL1")
#! Field("MGNT:BSY0:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:BSY0:1:ALLQUADSGO.LNK1")
#! Link("MGNT:BSY0:1:ALLQUADSGO.LNK1","MGNT:BSY0:1:ALLQUADS.VAL")
#! Record("MGNT:BSY0:1:ALLQUADS",540,102,0,0,"MGNT:BSY0:1:ALLQUADS")
#! Field("MGNT:BSY0:1:ALLQUADS.VAL",16777215,0,"MGNT:BSY0:1:ALLQUADS.VAL")
#! Field("MGNT:BSY0:1:ALLQUADS.FLNK",16777215,1,"MGNT:BSY0:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:BSY0:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:BSY0:1:XCORSWITCH")
}

record(seq, "MGNT:BSY0:1:XCORSWITCH") {
  field(DOL1, "MGNT:BSY0:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:XCORCTRL")
}

record(seq, "MGNT:BSY0:1:ALLXCORSGO") {
  field(DOL1, "MGNT:BSY0:1:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:BSY0:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:XCORCTRL",20,10,0,0,"MGNT:BSY0:1:XCORCTRL")
#! Field("MGNT:BSY0:1:XCORCTRL.FLNK",16777215,1,"MGNT:BSY0:1:XCORCTRL.FLNK")
#! Link("MGNT:BSY0:1:XCORCTRL.FLNK","MGNT:BSY0:1:XCORSWITCH")
#! Field("MGNT:BSY0:1:XCORCTRL.FFVL",16777215,1,"MGNT:BSY0:1:XCORCTRL.FFVL")
#! Record("MGNT:BSY0:1:XCORSWITCH",460,322,0,0,"MGNT:BSY0:1:XCORSWITCH")
#! Field("MGNT:BSY0:1:XCORSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:XCORSWITCH.DOL1")
#! Link("MGNT:BSY0:1:XCORSWITCH.DOL1","MGNT:BSY0:1:XCORCTRL.FFVL")
#! Field("MGNT:BSY0:1:XCORSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:XCORSWITCH.LNK1")
#! Field("MGNT:BSY0:1:XCORSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:XCORSWITCH.FLNK")
#! Record("MGNT:BSY0:1:ALLXCORSGO",240,96,0,0,"MGNT:BSY0:1:ALLXCORSGO")
#! Field("MGNT:BSY0:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:BSY0:1:ALLXCORSGO.DOL1")
#! Field("MGNT:BSY0:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:BSY0:1:ALLXCORSGO.LNK1")
#! Link("MGNT:BSY0:1:ALLXCORSGO.LNK1","MGNT:BSY0:1:ALLXCORS.VAL")
#! Record("MGNT:BSY0:1:ALLXCORS",540,102,0,0,"MGNT:BSY0:1:ALLXCORS")
#! Field("MGNT:BSY0:1:ALLXCORS.VAL",16777215,0,"MGNT:BSY0:1:ALLXCORS.VAL")
#! Field("MGNT:BSY0:1:ALLXCORS.FLNK",16777215,1,"MGNT:BSY0:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:BSY0:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:BSY0:1:YCORSWITCH")
}

record(seq, "MGNT:BSY0:1:YCORSWITCH") {
  field(DOL1, "MGNT:BSY0:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:YCORCTRL")
}

record(seq, "MGNT:BSY0:1:ALLYCORSGO") {
  field(DOL1, "MGNT:BSY0:1:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:BSY0:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:YCORCTRL",20,10,0,0,"MGNT:BSY0:1:YCORCTRL")
#! Field("MGNT:BSY0:1:YCORCTRL.FLNK",16777215,1,"MGNT:BSY0:1:YCORCTRL.FLNK")
#! Link("MGNT:BSY0:1:YCORCTRL.FLNK","MGNT:BSY0:1:YCORSWITCH")
#! Field("MGNT:BSY0:1:YCORCTRL.FFVL",16777215,1,"MGNT:BSY0:1:YCORCTRL.FFVL")
#! Record("MGNT:BSY0:1:YCORSWITCH",460,322,0,0,"MGNT:BSY0:1:YCORSWITCH")
#! Field("MGNT:BSY0:1:YCORSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:YCORSWITCH.DOL1")
#! Link("MGNT:BSY0:1:YCORSWITCH.DOL1","MGNT:BSY0:1:YCORCTRL.FFVL")
#! Field("MGNT:BSY0:1:YCORSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:YCORSWITCH.LNK1")
#! Field("MGNT:BSY0:1:YCORSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:YCORSWITCH.FLNK")
#! Record("MGNT:BSY0:1:ALLYCORSGO",240,96,0,0,"MGNT:BSY0:1:ALLYCORSGO")
#! Field("MGNT:BSY0:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:BSY0:1:ALLYCORSGO.DOL1")
#! Field("MGNT:BSY0:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:BSY0:1:ALLYCORSGO.LNK1")
#! Link("MGNT:BSY0:1:ALLYCORSGO.LNK1","MGNT:BSY0:1:ALLYCORS.VAL")
#! Record("MGNT:BSY0:1:ALLYCORS",540,102,0,0,"MGNT:BSY0:1:ALLYCORS")
#! Field("MGNT:BSY0:1:ALLYCORS.VAL",16777215,0,"MGNT:BSY0:1:ALLYCORS.VAL")
#! Field("MGNT:BSY0:1:ALLYCORS.FLNK",16777215,1,"MGNT:BSY0:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:BSY0:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:BSY0:1:SOLNSWITCH")
}

record(seq, "MGNT:BSY0:1:SOLNSWITCH") {
  field(DOL1, "MGNT:BSY0:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:SOLNCTRL")
}

record(seq, "MGNT:BSY0:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:BSY0:1:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:BSY0:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:SOLNCTRL",20,10,0,0,"MGNT:BSY0:1:SOLNCTRL")
#! Field("MGNT:BSY0:1:SOLNCTRL.FLNK",16777215,1,"MGNT:BSY0:1:SOLNCTRL.FLNK")
#! Link("MGNT:BSY0:1:SOLNCTRL.FLNK","MGNT:BSY0:1:SOLNSWITCH")
#! Field("MGNT:BSY0:1:SOLNCTRL.FFVL",16777215,1,"MGNT:BSY0:1:SOLNCTRL.FFVL")
#! Record("MGNT:BSY0:1:SOLNSWITCH",460,322,0,0,"MGNT:BSY0:1:SOLNSWITCH")
#! Field("MGNT:BSY0:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:SOLNSWITCH.DOL1")
#! Link("MGNT:BSY0:1:SOLNSWITCH.DOL1","MGNT:BSY0:1:SOLNCTRL.FFVL")
#! Field("MGNT:BSY0:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:SOLNSWITCH.LNK1")
#! Field("MGNT:BSY0:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:SOLNSWITCH.FLNK")
#! Record("MGNT:BSY0:1:ALLSOLNSGO",240,96,0,0,"MGNT:BSY0:1:ALLSOLNSGO")
#! Field("MGNT:BSY0:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:BSY0:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:BSY0:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:BSY0:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:BSY0:1:ALLSOLNSGO.LNK1","MGNT:BSY0:1:ALLSOLNS.VAL")
#! Record("MGNT:BSY0:1:ALLSOLNS",540,102,0,0,"MGNT:BSY0:1:ALLSOLNS")
#! Field("MGNT:BSY0:1:ALLSOLNS.VAL",16777215,0,"MGNT:BSY0:1:ALLSOLNS.VAL")
#! Field("MGNT:BSY0:1:ALLSOLNS.FLNK",16777215,1,"MGNT:BSY0:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:BSY0:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:BSY0:1:KICKSWITCH")
}

record(seq, "MGNT:BSY0:1:KICKSWITCH") {
  field(DOL1, "MGNT:BSY0:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:KICKCTRL")
}

record(seq, "MGNT:BSY0:1:ALLKICKSGO") {
  field(DOL1, "MGNT:BSY0:1:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:BSY0:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:KICKCTRL",20,10,0,0,"MGNT:BSY0:1:KICKCTRL")
#! Field("MGNT:BSY0:1:KICKCTRL.FLNK",16777215,1,"MGNT:BSY0:1:KICKCTRL.FLNK")
#! Link("MGNT:BSY0:1:KICKCTRL.FLNK","MGNT:BSY0:1:KICKSWITCH")
#! Field("MGNT:BSY0:1:KICKCTRL.FFVL",16777215,1,"MGNT:BSY0:1:KICKCTRL.FFVL")
#! Record("MGNT:BSY0:1:KICKSWITCH",460,322,0,0,"MGNT:BSY0:1:KICKSWITCH")
#! Field("MGNT:BSY0:1:KICKSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:KICKSWITCH.DOL1")
#! Link("MGNT:BSY0:1:KICKSWITCH.DOL1","MGNT:BSY0:1:KICKCTRL.FFVL")
#! Field("MGNT:BSY0:1:KICKSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:KICKSWITCH.LNK1")
#! Field("MGNT:BSY0:1:KICKSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:KICKSWITCH.FLNK")
#! Record("MGNT:BSY0:1:ALLKICKSGO",240,96,0,0,"MGNT:BSY0:1:ALLKICKSGO")
#! Field("MGNT:BSY0:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:BSY0:1:ALLKICKSGO.DOL1")
#! Field("MGNT:BSY0:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:BSY0:1:ALLKICKSGO.LNK1")
#! Link("MGNT:BSY0:1:ALLKICKSGO.LNK1","MGNT:BSY0:1:ALLKICKS.VAL")
#! Record("MGNT:BSY0:1:ALLKICKS",540,102,0,0,"MGNT:BSY0:1:ALLKICKS")
#! Field("MGNT:BSY0:1:ALLKICKS.VAL",16777215,0,"MGNT:BSY0:1:ALLKICKS.VAL")
#! Field("MGNT:BSY0:1:ALLKICKS.FLNK",16777215,1,"MGNT:BSY0:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:BSY0:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:BSY0:1:SEXTSWITCH")
}

record(seq, "MGNT:BSY0:1:SEXTSWITCH") {
  field(DOL1, "MGNT:BSY0:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:SEXTCTRL")
}

record(seq, "MGNT:BSY0:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:BSY0:1:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:BSY0:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:SEXTCTRL",20,10,0,0,"MGNT:BSY0:1:SEXTCTRL")
#! Field("MGNT:BSY0:1:SEXTCTRL.FLNK",16777215,1,"MGNT:BSY0:1:SEXTCTRL.FLNK")
#! Link("MGNT:BSY0:1:SEXTCTRL.FLNK","MGNT:BSY0:1:SEXTSWITCH")
#! Field("MGNT:BSY0:1:SEXTCTRL.FFVL",16777215,1,"MGNT:BSY0:1:SEXTCTRL.FFVL")
#! Record("MGNT:BSY0:1:SEXTSWITCH",460,322,0,0,"MGNT:BSY0:1:SEXTSWITCH")
#! Field("MGNT:BSY0:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:SEXTSWITCH.DOL1")
#! Link("MGNT:BSY0:1:SEXTSWITCH.DOL1","MGNT:BSY0:1:SEXTCTRL.FFVL")
#! Field("MGNT:BSY0:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:SEXTSWITCH.LNK1")
#! Field("MGNT:BSY0:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:SEXTSWITCH.FLNK")
#! Record("MGNT:BSY0:1:ALLSEXTSGO",240,96,0,0,"MGNT:BSY0:1:ALLSEXTSGO")
#! Field("MGNT:BSY0:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:BSY0:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:BSY0:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:BSY0:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:BSY0:1:ALLSEXTSGO.LNK1","MGNT:BSY0:1:ALLSEXTS.VAL")
#! Record("MGNT:BSY0:1:ALLSEXTS",540,102,0,0,"MGNT:BSY0:1:ALLSEXTS")
#! Field("MGNT:BSY0:1:ALLSEXTS.VAL",16777215,0,"MGNT:BSY0:1:ALLSEXTS.VAL")
#! Field("MGNT:BSY0:1:ALLSEXTS.FLNK",16777215,1,"MGNT:BSY0:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:BSY0:1:CU:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:BSY0:1:CU:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:BSY0:1:CU:CTRL CA PP")
  field(LNK2, "MGNT:BSY0:1:CU:BENDCTRL CA PP")
  field(LNK3, "MGNT:BSY0:1:CU:BTRMCTRL CA PP")
  field(LNK4, "MGNT:BSY0:1:CU:LGPSCTRL CA PP")
  field(LNK5, "MGNT:BSY0:1:CU:QUADCTRL CA PP")
  field(LNK6, "MGNT:BSY0:1:CU:XCORCTRL CA PP")
  field(LNK7, "MGNT:BSY0:1:CU:YCORCTRL CA PP")
  field(LNK8, "MGNT:BSY0:1:CU:SOLNCTRL CA PP")
  field(LNK9, "MGNT:BSY0:1:CU:KICKCTRL CA PP")
  field(LNKA, "MGNT:BSY0:1:CU:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:BSY0:1:CU:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:BSY0:1:CU:ALLSWITCH")
}

record(seq, "MGNT:BSY0:1:CU:ALLSWITCH") {
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CU:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:CU:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:CU:CTRL")
}

record(bo, "MGNT:BSY0:1:CU:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:BSY0:1:CU:ALLSTARGO")
}

record(fanout, "MGNT:BSY0:1:CU:ALLSTARGO") {
  field(LNK1, "MGNT:BSY0:1:CU:ALLBENDSGO")
  field(LNK2, "MGNT:BSY0:1:CU:ALLBTRMSGO")
  field(LNK3, "MGNT:BSY0:1:CU:ALLLGPSSGO")
  field(LNK4, "MGNT:BSY0:1:CU:ALLQUADSGO")
  field(LNK5, "MGNT:BSY0:1:CU:ALLXCORSGO")
  field(LNK6, "MGNT:BSY0:1:CU:ALLYCORSGO")
  field(FLNK, "MGNT:BSY0:1:CU:ALLSTARGO_2")
}
record(fanout, "MGNT:BSY0:1:CU:ALLSTARGO_2") {
  field(LNK1, "MGNT:BSY0:1:CU:ALLSOLNSGO")
  field(LNK2, "MGNT:BSY0:1:CU:ALLKICKSGO")
  field(LNK3, "MGNT:BSY0:1:CU:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:BSY0:1:CU:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:BSY0:1:CU:BENDSWITCH")
}

record(seq, "MGNT:BSY0:1:CU:BENDSWITCH") {
  field(DOL1, "MGNT:BSY0:1:CU:BENDCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CU:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:CU:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:CU:BENDCTRL")
}

record(seq, "MGNT:BSY0:1:CU:ALLBENDSGO") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:CU:ALLBENDS PP NMS")
}

record(bo, "MGNT:BSY0:1:CU:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:CU:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:CU:BENDCTRL",20,10,0,0,"MGNT:BSY0:1:CU:BENDCTRL")
#! Field("MGNT:BSY0:1:CU:BENDCTRL.FLNK",16777215,1,"MGNT:BSY0:1:CU:BENDCTRL.FLNK")
#! Link("MGNT:BSY0:1:CU:BENDCTRL.FLNK","MGNT:BSY0:1:CU:BENDSWITCH")
#! Field("MGNT:BSY0:1:CU:BENDCTRL.FFVL",16777215,1,"MGNT:BSY0:1:CU:BENDCTRL.FFVL")
#! Record("MGNT:BSY0:1:CU:BENDSWITCH",460,322,0,0,"MGNT:BSY0:1:CU:BENDSWITCH")
#! Field("MGNT:BSY0:1:CU:BENDSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:CU:BENDSWITCH.DOL1")
#! Link("MGNT:BSY0:1:CU:BENDSWITCH.DOL1","MGNT:BSY0:1:CU:BENDCTRL.FFVL")
#! Field("MGNT:BSY0:1:CU:BENDSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:CU:BENDSWITCH.LNK1")
#! Field("MGNT:BSY0:1:CU:BENDSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:CU:BENDSWITCH.FLNK")
#! Record("MGNT:BSY0:1:CU:ALLBENDSGO",240,96,0,0,"MGNT:BSY0:1:CU:ALLBENDSGO")
#! Field("MGNT:BSY0:1:CU:ALLBENDSGO.DOL1",16777215,1,"MGNT:BSY0:1:CU:ALLBENDSGO.DOL1")
#! Field("MGNT:BSY0:1:CU:ALLBENDSGO.LNK1",16777215,1,"MGNT:BSY0:1:CU:ALLBENDSGO.LNK1")
#! Link("MGNT:BSY0:1:CU:ALLBENDSGO.LNK1","MGNT:BSY0:1:CU:ALLBENDS.VAL")
#! Record("MGNT:BSY0:1:CU:ALLBENDS",540,102,0,0,"MGNT:BSY0:1:CU:ALLBENDS")
#! Field("MGNT:BSY0:1:CU:ALLBENDS.VAL",16777215,0,"MGNT:BSY0:1:CU:ALLBENDS.VAL")
#! Field("MGNT:BSY0:1:CU:ALLBENDS.FLNK",16777215,1,"MGNT:BSY0:1:CU:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:BSY0:1:CU:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:BSY0:1:CU:BTRMSWITCH")
}

record(seq, "MGNT:BSY0:1:CU:BTRMSWITCH") {
  field(DOL1, "MGNT:BSY0:1:CU:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CU:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:CU:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:CU:BTRMCTRL")
}

record(seq, "MGNT:BSY0:1:CU:ALLBTRMSGO") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:CU:ALLBTRMS PP NMS")
}

record(bo, "MGNT:BSY0:1:CU:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:CU:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:CU:BTRMCTRL",20,10,0,0,"MGNT:BSY0:1:CU:BTRMCTRL")
#! Field("MGNT:BSY0:1:CU:BTRMCTRL.FLNK",16777215,1,"MGNT:BSY0:1:CU:BTRMCTRL.FLNK")
#! Link("MGNT:BSY0:1:CU:BTRMCTRL.FLNK","MGNT:BSY0:1:CU:BTRMSWITCH")
#! Field("MGNT:BSY0:1:CU:BTRMCTRL.FFVL",16777215,1,"MGNT:BSY0:1:CU:BTRMCTRL.FFVL")
#! Record("MGNT:BSY0:1:CU:BTRMSWITCH",460,322,0,0,"MGNT:BSY0:1:CU:BTRMSWITCH")
#! Field("MGNT:BSY0:1:CU:BTRMSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:CU:BTRMSWITCH.DOL1")
#! Link("MGNT:BSY0:1:CU:BTRMSWITCH.DOL1","MGNT:BSY0:1:CU:BTRMCTRL.FFVL")
#! Field("MGNT:BSY0:1:CU:BTRMSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:CU:BTRMSWITCH.LNK1")
#! Field("MGNT:BSY0:1:CU:BTRMSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:CU:BTRMSWITCH.FLNK")
#! Record("MGNT:BSY0:1:CU:ALLBTRMSGO",240,96,0,0,"MGNT:BSY0:1:CU:ALLBTRMSGO")
#! Field("MGNT:BSY0:1:CU:ALLBTRMSGO.DOL1",16777215,1,"MGNT:BSY0:1:CU:ALLBTRMSGO.DOL1")
#! Field("MGNT:BSY0:1:CU:ALLBTRMSGO.LNK1",16777215,1,"MGNT:BSY0:1:CU:ALLBTRMSGO.LNK1")
#! Link("MGNT:BSY0:1:CU:ALLBTRMSGO.LNK1","MGNT:BSY0:1:CU:ALLBTRMS.VAL")
#! Record("MGNT:BSY0:1:CU:ALLBTRMS",540,102,0,0,"MGNT:BSY0:1:CU:ALLBTRMS")
#! Field("MGNT:BSY0:1:CU:ALLBTRMS.VAL",16777215,0,"MGNT:BSY0:1:CU:ALLBTRMS.VAL")
#! Field("MGNT:BSY0:1:CU:ALLBTRMS.FLNK",16777215,1,"MGNT:BSY0:1:CU:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:BSY0:1:CU:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:BSY0:1:CU:LGPSSWITCH")
}

record(seq, "MGNT:BSY0:1:CU:LGPSSWITCH") {
  field(DOL1, "MGNT:BSY0:1:CU:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CU:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:CU:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:CU:LGPSCTRL")
}

record(seq, "MGNT:BSY0:1:CU:ALLLGPSSGO") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:CU:ALLLGPSS PP NMS")
}

record(bo, "MGNT:BSY0:1:CU:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:CU:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:CU:LGPSCTRL",20,10,0,0,"MGNT:BSY0:1:CU:LGPSCTRL")
#! Field("MGNT:BSY0:1:CU:LGPSCTRL.FLNK",16777215,1,"MGNT:BSY0:1:CU:LGPSCTRL.FLNK")
#! Link("MGNT:BSY0:1:CU:LGPSCTRL.FLNK","MGNT:BSY0:1:CU:LGPSSWITCH")
#! Field("MGNT:BSY0:1:CU:LGPSCTRL.FFVL",16777215,1,"MGNT:BSY0:1:CU:LGPSCTRL.FFVL")
#! Record("MGNT:BSY0:1:CU:LGPSSWITCH",460,322,0,0,"MGNT:BSY0:1:CU:LGPSSWITCH")
#! Field("MGNT:BSY0:1:CU:LGPSSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:CU:LGPSSWITCH.DOL1")
#! Link("MGNT:BSY0:1:CU:LGPSSWITCH.DOL1","MGNT:BSY0:1:CU:LGPSCTRL.FFVL")
#! Field("MGNT:BSY0:1:CU:LGPSSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:CU:LGPSSWITCH.LNK1")
#! Field("MGNT:BSY0:1:CU:LGPSSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:CU:LGPSSWITCH.FLNK")
#! Record("MGNT:BSY0:1:CU:ALLLGPSSGO",240,96,0,0,"MGNT:BSY0:1:CU:ALLLGPSSGO")
#! Field("MGNT:BSY0:1:CU:ALLLGPSSGO.DOL1",16777215,1,"MGNT:BSY0:1:CU:ALLLGPSSGO.DOL1")
#! Field("MGNT:BSY0:1:CU:ALLLGPSSGO.LNK1",16777215,1,"MGNT:BSY0:1:CU:ALLLGPSSGO.LNK1")
#! Link("MGNT:BSY0:1:CU:ALLLGPSSGO.LNK1","MGNT:BSY0:1:CU:ALLLGPSS.VAL")
#! Record("MGNT:BSY0:1:CU:ALLLGPSS",540,102,0,0,"MGNT:BSY0:1:CU:ALLLGPSS")
#! Field("MGNT:BSY0:1:CU:ALLLGPSS.VAL",16777215,0,"MGNT:BSY0:1:CU:ALLLGPSS.VAL")
#! Field("MGNT:BSY0:1:CU:ALLLGPSS.FLNK",16777215,1,"MGNT:BSY0:1:CU:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:BSY0:1:CU:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:BSY0:1:CU:QUADSWITCH")
}

record(seq, "MGNT:BSY0:1:CU:QUADSWITCH") {
  field(DOL1, "MGNT:BSY0:1:CU:QUADCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CU:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:CU:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:CU:QUADCTRL")
}

record(seq, "MGNT:BSY0:1:CU:ALLQUADSGO") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:CU:ALLQUADS PP NMS")
}

record(bo, "MGNT:BSY0:1:CU:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:CU:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:CU:QUADCTRL",20,10,0,0,"MGNT:BSY0:1:CU:QUADCTRL")
#! Field("MGNT:BSY0:1:CU:QUADCTRL.FLNK",16777215,1,"MGNT:BSY0:1:CU:QUADCTRL.FLNK")
#! Link("MGNT:BSY0:1:CU:QUADCTRL.FLNK","MGNT:BSY0:1:CU:QUADSWITCH")
#! Field("MGNT:BSY0:1:CU:QUADCTRL.FFVL",16777215,1,"MGNT:BSY0:1:CU:QUADCTRL.FFVL")
#! Record("MGNT:BSY0:1:CU:QUADSWITCH",460,322,0,0,"MGNT:BSY0:1:CU:QUADSWITCH")
#! Field("MGNT:BSY0:1:CU:QUADSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:CU:QUADSWITCH.DOL1")
#! Link("MGNT:BSY0:1:CU:QUADSWITCH.DOL1","MGNT:BSY0:1:CU:QUADCTRL.FFVL")
#! Field("MGNT:BSY0:1:CU:QUADSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:CU:QUADSWITCH.LNK1")
#! Field("MGNT:BSY0:1:CU:QUADSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:CU:QUADSWITCH.FLNK")
#! Record("MGNT:BSY0:1:CU:ALLQUADSGO",240,96,0,0,"MGNT:BSY0:1:CU:ALLQUADSGO")
#! Field("MGNT:BSY0:1:CU:ALLQUADSGO.DOL1",16777215,1,"MGNT:BSY0:1:CU:ALLQUADSGO.DOL1")
#! Field("MGNT:BSY0:1:CU:ALLQUADSGO.LNK1",16777215,1,"MGNT:BSY0:1:CU:ALLQUADSGO.LNK1")
#! Link("MGNT:BSY0:1:CU:ALLQUADSGO.LNK1","MGNT:BSY0:1:CU:ALLQUADS.VAL")
#! Record("MGNT:BSY0:1:CU:ALLQUADS",540,102,0,0,"MGNT:BSY0:1:CU:ALLQUADS")
#! Field("MGNT:BSY0:1:CU:ALLQUADS.VAL",16777215,0,"MGNT:BSY0:1:CU:ALLQUADS.VAL")
#! Field("MGNT:BSY0:1:CU:ALLQUADS.FLNK",16777215,1,"MGNT:BSY0:1:CU:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:BSY0:1:CU:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:BSY0:1:CU:XCORSWITCH")
}

record(seq, "MGNT:BSY0:1:CU:XCORSWITCH") {
  field(DOL1, "MGNT:BSY0:1:CU:XCORCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CU:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:CU:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:CU:XCORCTRL")
}

record(seq, "MGNT:BSY0:1:CU:ALLXCORSGO") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:CU:ALLXCORS PP NMS")
}

record(bo, "MGNT:BSY0:1:CU:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:CU:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:CU:XCORCTRL",20,10,0,0,"MGNT:BSY0:1:CU:XCORCTRL")
#! Field("MGNT:BSY0:1:CU:XCORCTRL.FLNK",16777215,1,"MGNT:BSY0:1:CU:XCORCTRL.FLNK")
#! Link("MGNT:BSY0:1:CU:XCORCTRL.FLNK","MGNT:BSY0:1:CU:XCORSWITCH")
#! Field("MGNT:BSY0:1:CU:XCORCTRL.FFVL",16777215,1,"MGNT:BSY0:1:CU:XCORCTRL.FFVL")
#! Record("MGNT:BSY0:1:CU:XCORSWITCH",460,322,0,0,"MGNT:BSY0:1:CU:XCORSWITCH")
#! Field("MGNT:BSY0:1:CU:XCORSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:CU:XCORSWITCH.DOL1")
#! Link("MGNT:BSY0:1:CU:XCORSWITCH.DOL1","MGNT:BSY0:1:CU:XCORCTRL.FFVL")
#! Field("MGNT:BSY0:1:CU:XCORSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:CU:XCORSWITCH.LNK1")
#! Field("MGNT:BSY0:1:CU:XCORSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:CU:XCORSWITCH.FLNK")
#! Record("MGNT:BSY0:1:CU:ALLXCORSGO",240,96,0,0,"MGNT:BSY0:1:CU:ALLXCORSGO")
#! Field("MGNT:BSY0:1:CU:ALLXCORSGO.DOL1",16777215,1,"MGNT:BSY0:1:CU:ALLXCORSGO.DOL1")
#! Field("MGNT:BSY0:1:CU:ALLXCORSGO.LNK1",16777215,1,"MGNT:BSY0:1:CU:ALLXCORSGO.LNK1")
#! Link("MGNT:BSY0:1:CU:ALLXCORSGO.LNK1","MGNT:BSY0:1:CU:ALLXCORS.VAL")
#! Record("MGNT:BSY0:1:CU:ALLXCORS",540,102,0,0,"MGNT:BSY0:1:CU:ALLXCORS")
#! Field("MGNT:BSY0:1:CU:ALLXCORS.VAL",16777215,0,"MGNT:BSY0:1:CU:ALLXCORS.VAL")
#! Field("MGNT:BSY0:1:CU:ALLXCORS.FLNK",16777215,1,"MGNT:BSY0:1:CU:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:BSY0:1:CU:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:BSY0:1:CU:YCORSWITCH")
}

record(seq, "MGNT:BSY0:1:CU:YCORSWITCH") {
  field(DOL1, "MGNT:BSY0:1:CU:YCORCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CU:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:CU:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:CU:YCORCTRL")
}

record(seq, "MGNT:BSY0:1:CU:ALLYCORSGO") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:CU:ALLYCORS PP NMS")
}

record(bo, "MGNT:BSY0:1:CU:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:CU:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:CU:YCORCTRL",20,10,0,0,"MGNT:BSY0:1:CU:YCORCTRL")
#! Field("MGNT:BSY0:1:CU:YCORCTRL.FLNK",16777215,1,"MGNT:BSY0:1:CU:YCORCTRL.FLNK")
#! Link("MGNT:BSY0:1:CU:YCORCTRL.FLNK","MGNT:BSY0:1:CU:YCORSWITCH")
#! Field("MGNT:BSY0:1:CU:YCORCTRL.FFVL",16777215,1,"MGNT:BSY0:1:CU:YCORCTRL.FFVL")
#! Record("MGNT:BSY0:1:CU:YCORSWITCH",460,322,0,0,"MGNT:BSY0:1:CU:YCORSWITCH")
#! Field("MGNT:BSY0:1:CU:YCORSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:CU:YCORSWITCH.DOL1")
#! Link("MGNT:BSY0:1:CU:YCORSWITCH.DOL1","MGNT:BSY0:1:CU:YCORCTRL.FFVL")
#! Field("MGNT:BSY0:1:CU:YCORSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:CU:YCORSWITCH.LNK1")
#! Field("MGNT:BSY0:1:CU:YCORSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:CU:YCORSWITCH.FLNK")
#! Record("MGNT:BSY0:1:CU:ALLYCORSGO",240,96,0,0,"MGNT:BSY0:1:CU:ALLYCORSGO")
#! Field("MGNT:BSY0:1:CU:ALLYCORSGO.DOL1",16777215,1,"MGNT:BSY0:1:CU:ALLYCORSGO.DOL1")
#! Field("MGNT:BSY0:1:CU:ALLYCORSGO.LNK1",16777215,1,"MGNT:BSY0:1:CU:ALLYCORSGO.LNK1")
#! Link("MGNT:BSY0:1:CU:ALLYCORSGO.LNK1","MGNT:BSY0:1:CU:ALLYCORS.VAL")
#! Record("MGNT:BSY0:1:CU:ALLYCORS",540,102,0,0,"MGNT:BSY0:1:CU:ALLYCORS")
#! Field("MGNT:BSY0:1:CU:ALLYCORS.VAL",16777215,0,"MGNT:BSY0:1:CU:ALLYCORS.VAL")
#! Field("MGNT:BSY0:1:CU:ALLYCORS.FLNK",16777215,1,"MGNT:BSY0:1:CU:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:BSY0:1:CU:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:BSY0:1:CU:SOLNSWITCH")
}

record(seq, "MGNT:BSY0:1:CU:SOLNSWITCH") {
  field(DOL1, "MGNT:BSY0:1:CU:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CU:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:CU:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:CU:SOLNCTRL")
}

record(seq, "MGNT:BSY0:1:CU:ALLSOLNSGO") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:CU:ALLSOLNS PP NMS")
}

record(bo, "MGNT:BSY0:1:CU:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:CU:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:CU:SOLNCTRL",20,10,0,0,"MGNT:BSY0:1:CU:SOLNCTRL")
#! Field("MGNT:BSY0:1:CU:SOLNCTRL.FLNK",16777215,1,"MGNT:BSY0:1:CU:SOLNCTRL.FLNK")
#! Link("MGNT:BSY0:1:CU:SOLNCTRL.FLNK","MGNT:BSY0:1:CU:SOLNSWITCH")
#! Field("MGNT:BSY0:1:CU:SOLNCTRL.FFVL",16777215,1,"MGNT:BSY0:1:CU:SOLNCTRL.FFVL")
#! Record("MGNT:BSY0:1:CU:SOLNSWITCH",460,322,0,0,"MGNT:BSY0:1:CU:SOLNSWITCH")
#! Field("MGNT:BSY0:1:CU:SOLNSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:CU:SOLNSWITCH.DOL1")
#! Link("MGNT:BSY0:1:CU:SOLNSWITCH.DOL1","MGNT:BSY0:1:CU:SOLNCTRL.FFVL")
#! Field("MGNT:BSY0:1:CU:SOLNSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:CU:SOLNSWITCH.LNK1")
#! Field("MGNT:BSY0:1:CU:SOLNSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:CU:SOLNSWITCH.FLNK")
#! Record("MGNT:BSY0:1:CU:ALLSOLNSGO",240,96,0,0,"MGNT:BSY0:1:CU:ALLSOLNSGO")
#! Field("MGNT:BSY0:1:CU:ALLSOLNSGO.DOL1",16777215,1,"MGNT:BSY0:1:CU:ALLSOLNSGO.DOL1")
#! Field("MGNT:BSY0:1:CU:ALLSOLNSGO.LNK1",16777215,1,"MGNT:BSY0:1:CU:ALLSOLNSGO.LNK1")
#! Link("MGNT:BSY0:1:CU:ALLSOLNSGO.LNK1","MGNT:BSY0:1:CU:ALLSOLNS.VAL")
#! Record("MGNT:BSY0:1:CU:ALLSOLNS",540,102,0,0,"MGNT:BSY0:1:CU:ALLSOLNS")
#! Field("MGNT:BSY0:1:CU:ALLSOLNS.VAL",16777215,0,"MGNT:BSY0:1:CU:ALLSOLNS.VAL")
#! Field("MGNT:BSY0:1:CU:ALLSOLNS.FLNK",16777215,1,"MGNT:BSY0:1:CU:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:BSY0:1:CU:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:BSY0:1:CU:KICKSWITCH")
}

record(seq, "MGNT:BSY0:1:CU:KICKSWITCH") {
  field(DOL1, "MGNT:BSY0:1:CU:KICKCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CU:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:CU:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:CU:KICKCTRL")
}

record(seq, "MGNT:BSY0:1:CU:ALLKICKSGO") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:CU:ALLKICKS PP NMS")
}

record(bo, "MGNT:BSY0:1:CU:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:CU:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:CU:KICKCTRL",20,10,0,0,"MGNT:BSY0:1:CU:KICKCTRL")
#! Field("MGNT:BSY0:1:CU:KICKCTRL.FLNK",16777215,1,"MGNT:BSY0:1:CU:KICKCTRL.FLNK")
#! Link("MGNT:BSY0:1:CU:KICKCTRL.FLNK","MGNT:BSY0:1:CU:KICKSWITCH")
#! Field("MGNT:BSY0:1:CU:KICKCTRL.FFVL",16777215,1,"MGNT:BSY0:1:CU:KICKCTRL.FFVL")
#! Record("MGNT:BSY0:1:CU:KICKSWITCH",460,322,0,0,"MGNT:BSY0:1:CU:KICKSWITCH")
#! Field("MGNT:BSY0:1:CU:KICKSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:CU:KICKSWITCH.DOL1")
#! Link("MGNT:BSY0:1:CU:KICKSWITCH.DOL1","MGNT:BSY0:1:CU:KICKCTRL.FFVL")
#! Field("MGNT:BSY0:1:CU:KICKSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:CU:KICKSWITCH.LNK1")
#! Field("MGNT:BSY0:1:CU:KICKSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:CU:KICKSWITCH.FLNK")
#! Record("MGNT:BSY0:1:CU:ALLKICKSGO",240,96,0,0,"MGNT:BSY0:1:CU:ALLKICKSGO")
#! Field("MGNT:BSY0:1:CU:ALLKICKSGO.DOL1",16777215,1,"MGNT:BSY0:1:CU:ALLKICKSGO.DOL1")
#! Field("MGNT:BSY0:1:CU:ALLKICKSGO.LNK1",16777215,1,"MGNT:BSY0:1:CU:ALLKICKSGO.LNK1")
#! Link("MGNT:BSY0:1:CU:ALLKICKSGO.LNK1","MGNT:BSY0:1:CU:ALLKICKS.VAL")
#! Record("MGNT:BSY0:1:CU:ALLKICKS",540,102,0,0,"MGNT:BSY0:1:CU:ALLKICKS")
#! Field("MGNT:BSY0:1:CU:ALLKICKS.VAL",16777215,0,"MGNT:BSY0:1:CU:ALLKICKS.VAL")
#! Field("MGNT:BSY0:1:CU:ALLKICKS.FLNK",16777215,1,"MGNT:BSY0:1:CU:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:BSY0:1:CU:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:BSY0:1:CU:SEXTSWITCH")
}

record(seq, "MGNT:BSY0:1:CU:SEXTSWITCH") {
  field(DOL1, "MGNT:BSY0:1:CU:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:BSY0:1:CU:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BSY0:1:CU:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BSY0:1:CU:SEXTCTRL")
}

record(seq, "MGNT:BSY0:1:CU:ALLSEXTSGO") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLSTAR")
  field(LNK1, "MGNT:BSY0:1:CU:ALLSEXTS PP NMS")
}

record(bo, "MGNT:BSY0:1:CU:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BSY0:1:CU:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BSY0:1:CU:SEXTCTRL",20,10,0,0,"MGNT:BSY0:1:CU:SEXTCTRL")
#! Field("MGNT:BSY0:1:CU:SEXTCTRL.FLNK",16777215,1,"MGNT:BSY0:1:CU:SEXTCTRL.FLNK")
#! Link("MGNT:BSY0:1:CU:SEXTCTRL.FLNK","MGNT:BSY0:1:CU:SEXTSWITCH")
#! Field("MGNT:BSY0:1:CU:SEXTCTRL.FFVL",16777215,1,"MGNT:BSY0:1:CU:SEXTCTRL.FFVL")
#! Record("MGNT:BSY0:1:CU:SEXTSWITCH",460,322,0,0,"MGNT:BSY0:1:CU:SEXTSWITCH")
#! Field("MGNT:BSY0:1:CU:SEXTSWITCH.DOL1",16777215,0,"MGNT:BSY0:1:CU:SEXTSWITCH.DOL1")
#! Link("MGNT:BSY0:1:CU:SEXTSWITCH.DOL1","MGNT:BSY0:1:CU:SEXTCTRL.FFVL")
#! Field("MGNT:BSY0:1:CU:SEXTSWITCH.LNK1",16777215,1,"MGNT:BSY0:1:CU:SEXTSWITCH.LNK1")
#! Field("MGNT:BSY0:1:CU:SEXTSWITCH.FLNK",16777215,1,"MGNT:BSY0:1:CU:SEXTSWITCH.FLNK")
#! Record("MGNT:BSY0:1:CU:ALLSEXTSGO",240,96,0,0,"MGNT:BSY0:1:CU:ALLSEXTSGO")
#! Field("MGNT:BSY0:1:CU:ALLSEXTSGO.DOL1",16777215,1,"MGNT:BSY0:1:CU:ALLSEXTSGO.DOL1")
#! Field("MGNT:BSY0:1:CU:ALLSEXTSGO.LNK1",16777215,1,"MGNT:BSY0:1:CU:ALLSEXTSGO.LNK1")
#! Link("MGNT:BSY0:1:CU:ALLSEXTSGO.LNK1","MGNT:BSY0:1:CU:ALLSEXTS.VAL")
#! Record("MGNT:BSY0:1:CU:ALLSEXTS",540,102,0,0,"MGNT:BSY0:1:CU:ALLSEXTS")
#! Field("MGNT:BSY0:1:CU:ALLSEXTS.VAL",16777215,0,"MGNT:BSY0:1:CU:ALLSEXTS.VAL")
#! Field("MGNT:BSY0:1:CU:ALLSEXTS.FLNK",16777215,1,"MGNT:BSY0:1:CU:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:SLTH:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:SLTH:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:SLTH:1:CTRL CA PP")
  field(LNK2, "MGNT:SLTH:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:SLTH:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:SLTH:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:SLTH:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:SLTH:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:SLTH:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:SLTH:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:SLTH:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:SLTH:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:SLTH:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:SLTH:1:ALLSWITCH")
}

record(seq, "MGNT:SLTH:1:ALLSWITCH") {
  field(DOL1, "MGNT:SLTH:1:CTRL.FFVL")
  field(LNK1, "MGNT:SLTH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTH:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTH:1:CTRL")
}

record(bo, "MGNT:SLTH:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:SLTH:1:ALLSTARGO")
}

record(fanout, "MGNT:SLTH:1:ALLSTARGO") {
  field(LNK1, "MGNT:SLTH:1:ALLBENDSGO")
  field(LNK2, "MGNT:SLTH:1:ALLBTRMSGO")
  field(LNK3, "MGNT:SLTH:1:ALLLGPSSGO")
  field(LNK4, "MGNT:SLTH:1:ALLQUADSGO")
  field(LNK5, "MGNT:SLTH:1:ALLXCORSGO")
  field(LNK6, "MGNT:SLTH:1:ALLYCORSGO")
  field(FLNK, "MGNT:SLTH:1:ALLSTARGO_2")
}
record(fanout, "MGNT:SLTH:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:SLTH:1:ALLSOLNSGO")
  field(LNK2, "MGNT:SLTH:1:ALLKICKSGO")
  field(LNK3, "MGNT:SLTH:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:SLTH:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:SLTH:1:BENDSWITCH")
}

record(seq, "MGNT:SLTH:1:BENDSWITCH") {
  field(DOL1, "MGNT:SLTH:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:SLTH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTH:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTH:1:BENDCTRL")
}

record(seq, "MGNT:SLTH:1:ALLBENDSGO") {
  field(DOL1, "MGNT:SLTH:1:ALLSTAR")
  field(LNK1, "MGNT:SLTH:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:SLTH:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTH:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTH:1:BENDCTRL",20,10,0,0,"MGNT:SLTH:1:BENDCTRL")
#! Field("MGNT:SLTH:1:BENDCTRL.FLNK",16777215,1,"MGNT:SLTH:1:BENDCTRL.FLNK")
#! Link("MGNT:SLTH:1:BENDCTRL.FLNK","MGNT:SLTH:1:BENDSWITCH")
#! Field("MGNT:SLTH:1:BENDCTRL.FFVL",16777215,1,"MGNT:SLTH:1:BENDCTRL.FFVL")
#! Record("MGNT:SLTH:1:BENDSWITCH",460,322,0,0,"MGNT:SLTH:1:BENDSWITCH")
#! Field("MGNT:SLTH:1:BENDSWITCH.DOL1",16777215,0,"MGNT:SLTH:1:BENDSWITCH.DOL1")
#! Link("MGNT:SLTH:1:BENDSWITCH.DOL1","MGNT:SLTH:1:BENDCTRL.FFVL")
#! Field("MGNT:SLTH:1:BENDSWITCH.LNK1",16777215,1,"MGNT:SLTH:1:BENDSWITCH.LNK1")
#! Field("MGNT:SLTH:1:BENDSWITCH.FLNK",16777215,1,"MGNT:SLTH:1:BENDSWITCH.FLNK")
#! Record("MGNT:SLTH:1:ALLBENDSGO",240,96,0,0,"MGNT:SLTH:1:ALLBENDSGO")
#! Field("MGNT:SLTH:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:SLTH:1:ALLBENDSGO.DOL1")
#! Field("MGNT:SLTH:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:SLTH:1:ALLBENDSGO.LNK1")
#! Link("MGNT:SLTH:1:ALLBENDSGO.LNK1","MGNT:SLTH:1:ALLBENDS.VAL")
#! Record("MGNT:SLTH:1:ALLBENDS",540,102,0,0,"MGNT:SLTH:1:ALLBENDS")
#! Field("MGNT:SLTH:1:ALLBENDS.VAL",16777215,0,"MGNT:SLTH:1:ALLBENDS.VAL")
#! Field("MGNT:SLTH:1:ALLBENDS.FLNK",16777215,1,"MGNT:SLTH:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:SLTH:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:SLTH:1:BTRMSWITCH")
}

record(seq, "MGNT:SLTH:1:BTRMSWITCH") {
  field(DOL1, "MGNT:SLTH:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:SLTH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTH:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTH:1:BTRMCTRL")
}

record(seq, "MGNT:SLTH:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:SLTH:1:ALLSTAR")
  field(LNK1, "MGNT:SLTH:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:SLTH:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTH:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTH:1:BTRMCTRL",20,10,0,0,"MGNT:SLTH:1:BTRMCTRL")
#! Field("MGNT:SLTH:1:BTRMCTRL.FLNK",16777215,1,"MGNT:SLTH:1:BTRMCTRL.FLNK")
#! Link("MGNT:SLTH:1:BTRMCTRL.FLNK","MGNT:SLTH:1:BTRMSWITCH")
#! Field("MGNT:SLTH:1:BTRMCTRL.FFVL",16777215,1,"MGNT:SLTH:1:BTRMCTRL.FFVL")
#! Record("MGNT:SLTH:1:BTRMSWITCH",460,322,0,0,"MGNT:SLTH:1:BTRMSWITCH")
#! Field("MGNT:SLTH:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:SLTH:1:BTRMSWITCH.DOL1")
#! Link("MGNT:SLTH:1:BTRMSWITCH.DOL1","MGNT:SLTH:1:BTRMCTRL.FFVL")
#! Field("MGNT:SLTH:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:SLTH:1:BTRMSWITCH.LNK1")
#! Field("MGNT:SLTH:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:SLTH:1:BTRMSWITCH.FLNK")
#! Record("MGNT:SLTH:1:ALLBTRMSGO",240,96,0,0,"MGNT:SLTH:1:ALLBTRMSGO")
#! Field("MGNT:SLTH:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:SLTH:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:SLTH:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:SLTH:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:SLTH:1:ALLBTRMSGO.LNK1","MGNT:SLTH:1:ALLBTRMS.VAL")
#! Record("MGNT:SLTH:1:ALLBTRMS",540,102,0,0,"MGNT:SLTH:1:ALLBTRMS")
#! Field("MGNT:SLTH:1:ALLBTRMS.VAL",16777215,0,"MGNT:SLTH:1:ALLBTRMS.VAL")
#! Field("MGNT:SLTH:1:ALLBTRMS.FLNK",16777215,1,"MGNT:SLTH:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:SLTH:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:SLTH:1:LGPSSWITCH")
}

record(seq, "MGNT:SLTH:1:LGPSSWITCH") {
  field(DOL1, "MGNT:SLTH:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:SLTH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTH:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTH:1:LGPSCTRL")
}

record(seq, "MGNT:SLTH:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:SLTH:1:ALLSTAR")
  field(LNK1, "MGNT:SLTH:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:SLTH:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTH:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTH:1:LGPSCTRL",20,10,0,0,"MGNT:SLTH:1:LGPSCTRL")
#! Field("MGNT:SLTH:1:LGPSCTRL.FLNK",16777215,1,"MGNT:SLTH:1:LGPSCTRL.FLNK")
#! Link("MGNT:SLTH:1:LGPSCTRL.FLNK","MGNT:SLTH:1:LGPSSWITCH")
#! Field("MGNT:SLTH:1:LGPSCTRL.FFVL",16777215,1,"MGNT:SLTH:1:LGPSCTRL.FFVL")
#! Record("MGNT:SLTH:1:LGPSSWITCH",460,322,0,0,"MGNT:SLTH:1:LGPSSWITCH")
#! Field("MGNT:SLTH:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:SLTH:1:LGPSSWITCH.DOL1")
#! Link("MGNT:SLTH:1:LGPSSWITCH.DOL1","MGNT:SLTH:1:LGPSCTRL.FFVL")
#! Field("MGNT:SLTH:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:SLTH:1:LGPSSWITCH.LNK1")
#! Field("MGNT:SLTH:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:SLTH:1:LGPSSWITCH.FLNK")
#! Record("MGNT:SLTH:1:ALLLGPSSGO",240,96,0,0,"MGNT:SLTH:1:ALLLGPSSGO")
#! Field("MGNT:SLTH:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:SLTH:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:SLTH:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:SLTH:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:SLTH:1:ALLLGPSSGO.LNK1","MGNT:SLTH:1:ALLLGPSS.VAL")
#! Record("MGNT:SLTH:1:ALLLGPSS",540,102,0,0,"MGNT:SLTH:1:ALLLGPSS")
#! Field("MGNT:SLTH:1:ALLLGPSS.VAL",16777215,0,"MGNT:SLTH:1:ALLLGPSS.VAL")
#! Field("MGNT:SLTH:1:ALLLGPSS.FLNK",16777215,1,"MGNT:SLTH:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:SLTH:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:SLTH:1:QUADSWITCH")
}

record(seq, "MGNT:SLTH:1:QUADSWITCH") {
  field(DOL1, "MGNT:SLTH:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:SLTH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTH:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTH:1:QUADCTRL")
}

record(seq, "MGNT:SLTH:1:ALLQUADSGO") {
  field(DOL1, "MGNT:SLTH:1:ALLSTAR")
  field(LNK1, "MGNT:SLTH:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:SLTH:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTH:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTH:1:QUADCTRL",20,10,0,0,"MGNT:SLTH:1:QUADCTRL")
#! Field("MGNT:SLTH:1:QUADCTRL.FLNK",16777215,1,"MGNT:SLTH:1:QUADCTRL.FLNK")
#! Link("MGNT:SLTH:1:QUADCTRL.FLNK","MGNT:SLTH:1:QUADSWITCH")
#! Field("MGNT:SLTH:1:QUADCTRL.FFVL",16777215,1,"MGNT:SLTH:1:QUADCTRL.FFVL")
#! Record("MGNT:SLTH:1:QUADSWITCH",460,322,0,0,"MGNT:SLTH:1:QUADSWITCH")
#! Field("MGNT:SLTH:1:QUADSWITCH.DOL1",16777215,0,"MGNT:SLTH:1:QUADSWITCH.DOL1")
#! Link("MGNT:SLTH:1:QUADSWITCH.DOL1","MGNT:SLTH:1:QUADCTRL.FFVL")
#! Field("MGNT:SLTH:1:QUADSWITCH.LNK1",16777215,1,"MGNT:SLTH:1:QUADSWITCH.LNK1")
#! Field("MGNT:SLTH:1:QUADSWITCH.FLNK",16777215,1,"MGNT:SLTH:1:QUADSWITCH.FLNK")
#! Record("MGNT:SLTH:1:ALLQUADSGO",240,96,0,0,"MGNT:SLTH:1:ALLQUADSGO")
#! Field("MGNT:SLTH:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:SLTH:1:ALLQUADSGO.DOL1")
#! Field("MGNT:SLTH:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:SLTH:1:ALLQUADSGO.LNK1")
#! Link("MGNT:SLTH:1:ALLQUADSGO.LNK1","MGNT:SLTH:1:ALLQUADS.VAL")
#! Record("MGNT:SLTH:1:ALLQUADS",540,102,0,0,"MGNT:SLTH:1:ALLQUADS")
#! Field("MGNT:SLTH:1:ALLQUADS.VAL",16777215,0,"MGNT:SLTH:1:ALLQUADS.VAL")
#! Field("MGNT:SLTH:1:ALLQUADS.FLNK",16777215,1,"MGNT:SLTH:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:SLTH:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:SLTH:1:XCORSWITCH")
}

record(seq, "MGNT:SLTH:1:XCORSWITCH") {
  field(DOL1, "MGNT:SLTH:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:SLTH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTH:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTH:1:XCORCTRL")
}

record(seq, "MGNT:SLTH:1:ALLXCORSGO") {
  field(DOL1, "MGNT:SLTH:1:ALLSTAR")
  field(LNK1, "MGNT:SLTH:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:SLTH:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTH:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTH:1:XCORCTRL",20,10,0,0,"MGNT:SLTH:1:XCORCTRL")
#! Field("MGNT:SLTH:1:XCORCTRL.FLNK",16777215,1,"MGNT:SLTH:1:XCORCTRL.FLNK")
#! Link("MGNT:SLTH:1:XCORCTRL.FLNK","MGNT:SLTH:1:XCORSWITCH")
#! Field("MGNT:SLTH:1:XCORCTRL.FFVL",16777215,1,"MGNT:SLTH:1:XCORCTRL.FFVL")
#! Record("MGNT:SLTH:1:XCORSWITCH",460,322,0,0,"MGNT:SLTH:1:XCORSWITCH")
#! Field("MGNT:SLTH:1:XCORSWITCH.DOL1",16777215,0,"MGNT:SLTH:1:XCORSWITCH.DOL1")
#! Link("MGNT:SLTH:1:XCORSWITCH.DOL1","MGNT:SLTH:1:XCORCTRL.FFVL")
#! Field("MGNT:SLTH:1:XCORSWITCH.LNK1",16777215,1,"MGNT:SLTH:1:XCORSWITCH.LNK1")
#! Field("MGNT:SLTH:1:XCORSWITCH.FLNK",16777215,1,"MGNT:SLTH:1:XCORSWITCH.FLNK")
#! Record("MGNT:SLTH:1:ALLXCORSGO",240,96,0,0,"MGNT:SLTH:1:ALLXCORSGO")
#! Field("MGNT:SLTH:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:SLTH:1:ALLXCORSGO.DOL1")
#! Field("MGNT:SLTH:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:SLTH:1:ALLXCORSGO.LNK1")
#! Link("MGNT:SLTH:1:ALLXCORSGO.LNK1","MGNT:SLTH:1:ALLXCORS.VAL")
#! Record("MGNT:SLTH:1:ALLXCORS",540,102,0,0,"MGNT:SLTH:1:ALLXCORS")
#! Field("MGNT:SLTH:1:ALLXCORS.VAL",16777215,0,"MGNT:SLTH:1:ALLXCORS.VAL")
#! Field("MGNT:SLTH:1:ALLXCORS.FLNK",16777215,1,"MGNT:SLTH:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:SLTH:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:SLTH:1:YCORSWITCH")
}

record(seq, "MGNT:SLTH:1:YCORSWITCH") {
  field(DOL1, "MGNT:SLTH:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:SLTH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTH:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTH:1:YCORCTRL")
}

record(seq, "MGNT:SLTH:1:ALLYCORSGO") {
  field(DOL1, "MGNT:SLTH:1:ALLSTAR")
  field(LNK1, "MGNT:SLTH:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:SLTH:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTH:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTH:1:YCORCTRL",20,10,0,0,"MGNT:SLTH:1:YCORCTRL")
#! Field("MGNT:SLTH:1:YCORCTRL.FLNK",16777215,1,"MGNT:SLTH:1:YCORCTRL.FLNK")
#! Link("MGNT:SLTH:1:YCORCTRL.FLNK","MGNT:SLTH:1:YCORSWITCH")
#! Field("MGNT:SLTH:1:YCORCTRL.FFVL",16777215,1,"MGNT:SLTH:1:YCORCTRL.FFVL")
#! Record("MGNT:SLTH:1:YCORSWITCH",460,322,0,0,"MGNT:SLTH:1:YCORSWITCH")
#! Field("MGNT:SLTH:1:YCORSWITCH.DOL1",16777215,0,"MGNT:SLTH:1:YCORSWITCH.DOL1")
#! Link("MGNT:SLTH:1:YCORSWITCH.DOL1","MGNT:SLTH:1:YCORCTRL.FFVL")
#! Field("MGNT:SLTH:1:YCORSWITCH.LNK1",16777215,1,"MGNT:SLTH:1:YCORSWITCH.LNK1")
#! Field("MGNT:SLTH:1:YCORSWITCH.FLNK",16777215,1,"MGNT:SLTH:1:YCORSWITCH.FLNK")
#! Record("MGNT:SLTH:1:ALLYCORSGO",240,96,0,0,"MGNT:SLTH:1:ALLYCORSGO")
#! Field("MGNT:SLTH:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:SLTH:1:ALLYCORSGO.DOL1")
#! Field("MGNT:SLTH:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:SLTH:1:ALLYCORSGO.LNK1")
#! Link("MGNT:SLTH:1:ALLYCORSGO.LNK1","MGNT:SLTH:1:ALLYCORS.VAL")
#! Record("MGNT:SLTH:1:ALLYCORS",540,102,0,0,"MGNT:SLTH:1:ALLYCORS")
#! Field("MGNT:SLTH:1:ALLYCORS.VAL",16777215,0,"MGNT:SLTH:1:ALLYCORS.VAL")
#! Field("MGNT:SLTH:1:ALLYCORS.FLNK",16777215,1,"MGNT:SLTH:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:SLTH:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:SLTH:1:SOLNSWITCH")
}

record(seq, "MGNT:SLTH:1:SOLNSWITCH") {
  field(DOL1, "MGNT:SLTH:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:SLTH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTH:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTH:1:SOLNCTRL")
}

record(seq, "MGNT:SLTH:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:SLTH:1:ALLSTAR")
  field(LNK1, "MGNT:SLTH:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:SLTH:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTH:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTH:1:SOLNCTRL",20,10,0,0,"MGNT:SLTH:1:SOLNCTRL")
#! Field("MGNT:SLTH:1:SOLNCTRL.FLNK",16777215,1,"MGNT:SLTH:1:SOLNCTRL.FLNK")
#! Link("MGNT:SLTH:1:SOLNCTRL.FLNK","MGNT:SLTH:1:SOLNSWITCH")
#! Field("MGNT:SLTH:1:SOLNCTRL.FFVL",16777215,1,"MGNT:SLTH:1:SOLNCTRL.FFVL")
#! Record("MGNT:SLTH:1:SOLNSWITCH",460,322,0,0,"MGNT:SLTH:1:SOLNSWITCH")
#! Field("MGNT:SLTH:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:SLTH:1:SOLNSWITCH.DOL1")
#! Link("MGNT:SLTH:1:SOLNSWITCH.DOL1","MGNT:SLTH:1:SOLNCTRL.FFVL")
#! Field("MGNT:SLTH:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:SLTH:1:SOLNSWITCH.LNK1")
#! Field("MGNT:SLTH:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:SLTH:1:SOLNSWITCH.FLNK")
#! Record("MGNT:SLTH:1:ALLSOLNSGO",240,96,0,0,"MGNT:SLTH:1:ALLSOLNSGO")
#! Field("MGNT:SLTH:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:SLTH:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:SLTH:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:SLTH:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:SLTH:1:ALLSOLNSGO.LNK1","MGNT:SLTH:1:ALLSOLNS.VAL")
#! Record("MGNT:SLTH:1:ALLSOLNS",540,102,0,0,"MGNT:SLTH:1:ALLSOLNS")
#! Field("MGNT:SLTH:1:ALLSOLNS.VAL",16777215,0,"MGNT:SLTH:1:ALLSOLNS.VAL")
#! Field("MGNT:SLTH:1:ALLSOLNS.FLNK",16777215,1,"MGNT:SLTH:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:SLTH:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:SLTH:1:KICKSWITCH")
}

record(seq, "MGNT:SLTH:1:KICKSWITCH") {
  field(DOL1, "MGNT:SLTH:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:SLTH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTH:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTH:1:KICKCTRL")
}

record(seq, "MGNT:SLTH:1:ALLKICKSGO") {
  field(DOL1, "MGNT:SLTH:1:ALLSTAR")
  field(LNK1, "MGNT:SLTH:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:SLTH:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTH:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTH:1:KICKCTRL",20,10,0,0,"MGNT:SLTH:1:KICKCTRL")
#! Field("MGNT:SLTH:1:KICKCTRL.FLNK",16777215,1,"MGNT:SLTH:1:KICKCTRL.FLNK")
#! Link("MGNT:SLTH:1:KICKCTRL.FLNK","MGNT:SLTH:1:KICKSWITCH")
#! Field("MGNT:SLTH:1:KICKCTRL.FFVL",16777215,1,"MGNT:SLTH:1:KICKCTRL.FFVL")
#! Record("MGNT:SLTH:1:KICKSWITCH",460,322,0,0,"MGNT:SLTH:1:KICKSWITCH")
#! Field("MGNT:SLTH:1:KICKSWITCH.DOL1",16777215,0,"MGNT:SLTH:1:KICKSWITCH.DOL1")
#! Link("MGNT:SLTH:1:KICKSWITCH.DOL1","MGNT:SLTH:1:KICKCTRL.FFVL")
#! Field("MGNT:SLTH:1:KICKSWITCH.LNK1",16777215,1,"MGNT:SLTH:1:KICKSWITCH.LNK1")
#! Field("MGNT:SLTH:1:KICKSWITCH.FLNK",16777215,1,"MGNT:SLTH:1:KICKSWITCH.FLNK")
#! Record("MGNT:SLTH:1:ALLKICKSGO",240,96,0,0,"MGNT:SLTH:1:ALLKICKSGO")
#! Field("MGNT:SLTH:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:SLTH:1:ALLKICKSGO.DOL1")
#! Field("MGNT:SLTH:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:SLTH:1:ALLKICKSGO.LNK1")
#! Link("MGNT:SLTH:1:ALLKICKSGO.LNK1","MGNT:SLTH:1:ALLKICKS.VAL")
#! Record("MGNT:SLTH:1:ALLKICKS",540,102,0,0,"MGNT:SLTH:1:ALLKICKS")
#! Field("MGNT:SLTH:1:ALLKICKS.VAL",16777215,0,"MGNT:SLTH:1:ALLKICKS.VAL")
#! Field("MGNT:SLTH:1:ALLKICKS.FLNK",16777215,1,"MGNT:SLTH:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:SLTH:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:SLTH:1:SEXTSWITCH")
}

record(seq, "MGNT:SLTH:1:SEXTSWITCH") {
  field(DOL1, "MGNT:SLTH:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:SLTH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTH:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTH:1:SEXTCTRL")
}

record(seq, "MGNT:SLTH:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:SLTH:1:ALLSTAR")
  field(LNK1, "MGNT:SLTH:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:SLTH:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTH:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTH:1:SEXTCTRL",20,10,0,0,"MGNT:SLTH:1:SEXTCTRL")
#! Field("MGNT:SLTH:1:SEXTCTRL.FLNK",16777215,1,"MGNT:SLTH:1:SEXTCTRL.FLNK")
#! Link("MGNT:SLTH:1:SEXTCTRL.FLNK","MGNT:SLTH:1:SEXTSWITCH")
#! Field("MGNT:SLTH:1:SEXTCTRL.FFVL",16777215,1,"MGNT:SLTH:1:SEXTCTRL.FFVL")
#! Record("MGNT:SLTH:1:SEXTSWITCH",460,322,0,0,"MGNT:SLTH:1:SEXTSWITCH")
#! Field("MGNT:SLTH:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:SLTH:1:SEXTSWITCH.DOL1")
#! Link("MGNT:SLTH:1:SEXTSWITCH.DOL1","MGNT:SLTH:1:SEXTCTRL.FFVL")
#! Field("MGNT:SLTH:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:SLTH:1:SEXTSWITCH.LNK1")
#! Field("MGNT:SLTH:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:SLTH:1:SEXTSWITCH.FLNK")
#! Record("MGNT:SLTH:1:ALLSEXTSGO",240,96,0,0,"MGNT:SLTH:1:ALLSEXTSGO")
#! Field("MGNT:SLTH:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:SLTH:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:SLTH:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:SLTH:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:SLTH:1:ALLSEXTSGO.LNK1","MGNT:SLTH:1:ALLSEXTS.VAL")
#! Record("MGNT:SLTH:1:ALLSEXTS",540,102,0,0,"MGNT:SLTH:1:ALLSEXTS")
#! Field("MGNT:SLTH:1:ALLSEXTS.VAL",16777215,0,"MGNT:SLTH:1:ALLSEXTS.VAL")
#! Field("MGNT:SLTH:1:ALLSEXTS.FLNK",16777215,1,"MGNT:SLTH:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:SLTS:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:SLTS:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:SLTS:1:CTRL CA PP")
  field(LNK2, "MGNT:SLTS:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:SLTS:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:SLTS:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:SLTS:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:SLTS:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:SLTS:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:SLTS:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:SLTS:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:SLTS:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:SLTS:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:SLTS:1:ALLSWITCH")
}

record(seq, "MGNT:SLTS:1:ALLSWITCH") {
  field(DOL1, "MGNT:SLTS:1:CTRL.FFVL")
  field(LNK1, "MGNT:SLTS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTS:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTS:1:CTRL")
}

record(bo, "MGNT:SLTS:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:SLTS:1:ALLSTARGO")
}

record(fanout, "MGNT:SLTS:1:ALLSTARGO") {
  field(LNK1, "MGNT:SLTS:1:ALLBENDSGO")
  field(LNK2, "MGNT:SLTS:1:ALLBTRMSGO")
  field(LNK3, "MGNT:SLTS:1:ALLLGPSSGO")
  field(LNK4, "MGNT:SLTS:1:ALLQUADSGO")
  field(LNK5, "MGNT:SLTS:1:ALLXCORSGO")
  field(LNK6, "MGNT:SLTS:1:ALLYCORSGO")
  field(FLNK, "MGNT:SLTS:1:ALLSTARGO_2")
}
record(fanout, "MGNT:SLTS:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:SLTS:1:ALLSOLNSGO")
  field(LNK2, "MGNT:SLTS:1:ALLKICKSGO")
  field(LNK3, "MGNT:SLTS:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:SLTS:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:SLTS:1:BENDSWITCH")
}

record(seq, "MGNT:SLTS:1:BENDSWITCH") {
  field(DOL1, "MGNT:SLTS:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:SLTS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTS:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTS:1:BENDCTRL")
}

record(seq, "MGNT:SLTS:1:ALLBENDSGO") {
  field(DOL1, "MGNT:SLTS:1:ALLSTAR")
  field(LNK1, "MGNT:SLTS:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:SLTS:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTS:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTS:1:BENDCTRL",20,10,0,0,"MGNT:SLTS:1:BENDCTRL")
#! Field("MGNT:SLTS:1:BENDCTRL.FLNK",16777215,1,"MGNT:SLTS:1:BENDCTRL.FLNK")
#! Link("MGNT:SLTS:1:BENDCTRL.FLNK","MGNT:SLTS:1:BENDSWITCH")
#! Field("MGNT:SLTS:1:BENDCTRL.FFVL",16777215,1,"MGNT:SLTS:1:BENDCTRL.FFVL")
#! Record("MGNT:SLTS:1:BENDSWITCH",460,322,0,0,"MGNT:SLTS:1:BENDSWITCH")
#! Field("MGNT:SLTS:1:BENDSWITCH.DOL1",16777215,0,"MGNT:SLTS:1:BENDSWITCH.DOL1")
#! Link("MGNT:SLTS:1:BENDSWITCH.DOL1","MGNT:SLTS:1:BENDCTRL.FFVL")
#! Field("MGNT:SLTS:1:BENDSWITCH.LNK1",16777215,1,"MGNT:SLTS:1:BENDSWITCH.LNK1")
#! Field("MGNT:SLTS:1:BENDSWITCH.FLNK",16777215,1,"MGNT:SLTS:1:BENDSWITCH.FLNK")
#! Record("MGNT:SLTS:1:ALLBENDSGO",240,96,0,0,"MGNT:SLTS:1:ALLBENDSGO")
#! Field("MGNT:SLTS:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:SLTS:1:ALLBENDSGO.DOL1")
#! Field("MGNT:SLTS:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:SLTS:1:ALLBENDSGO.LNK1")
#! Link("MGNT:SLTS:1:ALLBENDSGO.LNK1","MGNT:SLTS:1:ALLBENDS.VAL")
#! Record("MGNT:SLTS:1:ALLBENDS",540,102,0,0,"MGNT:SLTS:1:ALLBENDS")
#! Field("MGNT:SLTS:1:ALLBENDS.VAL",16777215,0,"MGNT:SLTS:1:ALLBENDS.VAL")
#! Field("MGNT:SLTS:1:ALLBENDS.FLNK",16777215,1,"MGNT:SLTS:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:SLTS:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:SLTS:1:BTRMSWITCH")
}

record(seq, "MGNT:SLTS:1:BTRMSWITCH") {
  field(DOL1, "MGNT:SLTS:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:SLTS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTS:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTS:1:BTRMCTRL")
}

record(seq, "MGNT:SLTS:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:SLTS:1:ALLSTAR")
  field(LNK1, "MGNT:SLTS:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:SLTS:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTS:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTS:1:BTRMCTRL",20,10,0,0,"MGNT:SLTS:1:BTRMCTRL")
#! Field("MGNT:SLTS:1:BTRMCTRL.FLNK",16777215,1,"MGNT:SLTS:1:BTRMCTRL.FLNK")
#! Link("MGNT:SLTS:1:BTRMCTRL.FLNK","MGNT:SLTS:1:BTRMSWITCH")
#! Field("MGNT:SLTS:1:BTRMCTRL.FFVL",16777215,1,"MGNT:SLTS:1:BTRMCTRL.FFVL")
#! Record("MGNT:SLTS:1:BTRMSWITCH",460,322,0,0,"MGNT:SLTS:1:BTRMSWITCH")
#! Field("MGNT:SLTS:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:SLTS:1:BTRMSWITCH.DOL1")
#! Link("MGNT:SLTS:1:BTRMSWITCH.DOL1","MGNT:SLTS:1:BTRMCTRL.FFVL")
#! Field("MGNT:SLTS:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:SLTS:1:BTRMSWITCH.LNK1")
#! Field("MGNT:SLTS:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:SLTS:1:BTRMSWITCH.FLNK")
#! Record("MGNT:SLTS:1:ALLBTRMSGO",240,96,0,0,"MGNT:SLTS:1:ALLBTRMSGO")
#! Field("MGNT:SLTS:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:SLTS:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:SLTS:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:SLTS:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:SLTS:1:ALLBTRMSGO.LNK1","MGNT:SLTS:1:ALLBTRMS.VAL")
#! Record("MGNT:SLTS:1:ALLBTRMS",540,102,0,0,"MGNT:SLTS:1:ALLBTRMS")
#! Field("MGNT:SLTS:1:ALLBTRMS.VAL",16777215,0,"MGNT:SLTS:1:ALLBTRMS.VAL")
#! Field("MGNT:SLTS:1:ALLBTRMS.FLNK",16777215,1,"MGNT:SLTS:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:SLTS:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:SLTS:1:LGPSSWITCH")
}

record(seq, "MGNT:SLTS:1:LGPSSWITCH") {
  field(DOL1, "MGNT:SLTS:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:SLTS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTS:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTS:1:LGPSCTRL")
}

record(seq, "MGNT:SLTS:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:SLTS:1:ALLSTAR")
  field(LNK1, "MGNT:SLTS:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:SLTS:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTS:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTS:1:LGPSCTRL",20,10,0,0,"MGNT:SLTS:1:LGPSCTRL")
#! Field("MGNT:SLTS:1:LGPSCTRL.FLNK",16777215,1,"MGNT:SLTS:1:LGPSCTRL.FLNK")
#! Link("MGNT:SLTS:1:LGPSCTRL.FLNK","MGNT:SLTS:1:LGPSSWITCH")
#! Field("MGNT:SLTS:1:LGPSCTRL.FFVL",16777215,1,"MGNT:SLTS:1:LGPSCTRL.FFVL")
#! Record("MGNT:SLTS:1:LGPSSWITCH",460,322,0,0,"MGNT:SLTS:1:LGPSSWITCH")
#! Field("MGNT:SLTS:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:SLTS:1:LGPSSWITCH.DOL1")
#! Link("MGNT:SLTS:1:LGPSSWITCH.DOL1","MGNT:SLTS:1:LGPSCTRL.FFVL")
#! Field("MGNT:SLTS:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:SLTS:1:LGPSSWITCH.LNK1")
#! Field("MGNT:SLTS:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:SLTS:1:LGPSSWITCH.FLNK")
#! Record("MGNT:SLTS:1:ALLLGPSSGO",240,96,0,0,"MGNT:SLTS:1:ALLLGPSSGO")
#! Field("MGNT:SLTS:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:SLTS:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:SLTS:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:SLTS:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:SLTS:1:ALLLGPSSGO.LNK1","MGNT:SLTS:1:ALLLGPSS.VAL")
#! Record("MGNT:SLTS:1:ALLLGPSS",540,102,0,0,"MGNT:SLTS:1:ALLLGPSS")
#! Field("MGNT:SLTS:1:ALLLGPSS.VAL",16777215,0,"MGNT:SLTS:1:ALLLGPSS.VAL")
#! Field("MGNT:SLTS:1:ALLLGPSS.FLNK",16777215,1,"MGNT:SLTS:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:SLTS:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:SLTS:1:QUADSWITCH")
}

record(seq, "MGNT:SLTS:1:QUADSWITCH") {
  field(DOL1, "MGNT:SLTS:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:SLTS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTS:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTS:1:QUADCTRL")
}

record(seq, "MGNT:SLTS:1:ALLQUADSGO") {
  field(DOL1, "MGNT:SLTS:1:ALLSTAR")
  field(LNK1, "MGNT:SLTS:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:SLTS:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTS:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTS:1:QUADCTRL",20,10,0,0,"MGNT:SLTS:1:QUADCTRL")
#! Field("MGNT:SLTS:1:QUADCTRL.FLNK",16777215,1,"MGNT:SLTS:1:QUADCTRL.FLNK")
#! Link("MGNT:SLTS:1:QUADCTRL.FLNK","MGNT:SLTS:1:QUADSWITCH")
#! Field("MGNT:SLTS:1:QUADCTRL.FFVL",16777215,1,"MGNT:SLTS:1:QUADCTRL.FFVL")
#! Record("MGNT:SLTS:1:QUADSWITCH",460,322,0,0,"MGNT:SLTS:1:QUADSWITCH")
#! Field("MGNT:SLTS:1:QUADSWITCH.DOL1",16777215,0,"MGNT:SLTS:1:QUADSWITCH.DOL1")
#! Link("MGNT:SLTS:1:QUADSWITCH.DOL1","MGNT:SLTS:1:QUADCTRL.FFVL")
#! Field("MGNT:SLTS:1:QUADSWITCH.LNK1",16777215,1,"MGNT:SLTS:1:QUADSWITCH.LNK1")
#! Field("MGNT:SLTS:1:QUADSWITCH.FLNK",16777215,1,"MGNT:SLTS:1:QUADSWITCH.FLNK")
#! Record("MGNT:SLTS:1:ALLQUADSGO",240,96,0,0,"MGNT:SLTS:1:ALLQUADSGO")
#! Field("MGNT:SLTS:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:SLTS:1:ALLQUADSGO.DOL1")
#! Field("MGNT:SLTS:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:SLTS:1:ALLQUADSGO.LNK1")
#! Link("MGNT:SLTS:1:ALLQUADSGO.LNK1","MGNT:SLTS:1:ALLQUADS.VAL")
#! Record("MGNT:SLTS:1:ALLQUADS",540,102,0,0,"MGNT:SLTS:1:ALLQUADS")
#! Field("MGNT:SLTS:1:ALLQUADS.VAL",16777215,0,"MGNT:SLTS:1:ALLQUADS.VAL")
#! Field("MGNT:SLTS:1:ALLQUADS.FLNK",16777215,1,"MGNT:SLTS:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:SLTS:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:SLTS:1:XCORSWITCH")
}

record(seq, "MGNT:SLTS:1:XCORSWITCH") {
  field(DOL1, "MGNT:SLTS:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:SLTS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTS:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTS:1:XCORCTRL")
}

record(seq, "MGNT:SLTS:1:ALLXCORSGO") {
  field(DOL1, "MGNT:SLTS:1:ALLSTAR")
  field(LNK1, "MGNT:SLTS:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:SLTS:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTS:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTS:1:XCORCTRL",20,10,0,0,"MGNT:SLTS:1:XCORCTRL")
#! Field("MGNT:SLTS:1:XCORCTRL.FLNK",16777215,1,"MGNT:SLTS:1:XCORCTRL.FLNK")
#! Link("MGNT:SLTS:1:XCORCTRL.FLNK","MGNT:SLTS:1:XCORSWITCH")
#! Field("MGNT:SLTS:1:XCORCTRL.FFVL",16777215,1,"MGNT:SLTS:1:XCORCTRL.FFVL")
#! Record("MGNT:SLTS:1:XCORSWITCH",460,322,0,0,"MGNT:SLTS:1:XCORSWITCH")
#! Field("MGNT:SLTS:1:XCORSWITCH.DOL1",16777215,0,"MGNT:SLTS:1:XCORSWITCH.DOL1")
#! Link("MGNT:SLTS:1:XCORSWITCH.DOL1","MGNT:SLTS:1:XCORCTRL.FFVL")
#! Field("MGNT:SLTS:1:XCORSWITCH.LNK1",16777215,1,"MGNT:SLTS:1:XCORSWITCH.LNK1")
#! Field("MGNT:SLTS:1:XCORSWITCH.FLNK",16777215,1,"MGNT:SLTS:1:XCORSWITCH.FLNK")
#! Record("MGNT:SLTS:1:ALLXCORSGO",240,96,0,0,"MGNT:SLTS:1:ALLXCORSGO")
#! Field("MGNT:SLTS:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:SLTS:1:ALLXCORSGO.DOL1")
#! Field("MGNT:SLTS:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:SLTS:1:ALLXCORSGO.LNK1")
#! Link("MGNT:SLTS:1:ALLXCORSGO.LNK1","MGNT:SLTS:1:ALLXCORS.VAL")
#! Record("MGNT:SLTS:1:ALLXCORS",540,102,0,0,"MGNT:SLTS:1:ALLXCORS")
#! Field("MGNT:SLTS:1:ALLXCORS.VAL",16777215,0,"MGNT:SLTS:1:ALLXCORS.VAL")
#! Field("MGNT:SLTS:1:ALLXCORS.FLNK",16777215,1,"MGNT:SLTS:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:SLTS:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:SLTS:1:YCORSWITCH")
}

record(seq, "MGNT:SLTS:1:YCORSWITCH") {
  field(DOL1, "MGNT:SLTS:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:SLTS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTS:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTS:1:YCORCTRL")
}

record(seq, "MGNT:SLTS:1:ALLYCORSGO") {
  field(DOL1, "MGNT:SLTS:1:ALLSTAR")
  field(LNK1, "MGNT:SLTS:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:SLTS:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTS:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTS:1:YCORCTRL",20,10,0,0,"MGNT:SLTS:1:YCORCTRL")
#! Field("MGNT:SLTS:1:YCORCTRL.FLNK",16777215,1,"MGNT:SLTS:1:YCORCTRL.FLNK")
#! Link("MGNT:SLTS:1:YCORCTRL.FLNK","MGNT:SLTS:1:YCORSWITCH")
#! Field("MGNT:SLTS:1:YCORCTRL.FFVL",16777215,1,"MGNT:SLTS:1:YCORCTRL.FFVL")
#! Record("MGNT:SLTS:1:YCORSWITCH",460,322,0,0,"MGNT:SLTS:1:YCORSWITCH")
#! Field("MGNT:SLTS:1:YCORSWITCH.DOL1",16777215,0,"MGNT:SLTS:1:YCORSWITCH.DOL1")
#! Link("MGNT:SLTS:1:YCORSWITCH.DOL1","MGNT:SLTS:1:YCORCTRL.FFVL")
#! Field("MGNT:SLTS:1:YCORSWITCH.LNK1",16777215,1,"MGNT:SLTS:1:YCORSWITCH.LNK1")
#! Field("MGNT:SLTS:1:YCORSWITCH.FLNK",16777215,1,"MGNT:SLTS:1:YCORSWITCH.FLNK")
#! Record("MGNT:SLTS:1:ALLYCORSGO",240,96,0,0,"MGNT:SLTS:1:ALLYCORSGO")
#! Field("MGNT:SLTS:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:SLTS:1:ALLYCORSGO.DOL1")
#! Field("MGNT:SLTS:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:SLTS:1:ALLYCORSGO.LNK1")
#! Link("MGNT:SLTS:1:ALLYCORSGO.LNK1","MGNT:SLTS:1:ALLYCORS.VAL")
#! Record("MGNT:SLTS:1:ALLYCORS",540,102,0,0,"MGNT:SLTS:1:ALLYCORS")
#! Field("MGNT:SLTS:1:ALLYCORS.VAL",16777215,0,"MGNT:SLTS:1:ALLYCORS.VAL")
#! Field("MGNT:SLTS:1:ALLYCORS.FLNK",16777215,1,"MGNT:SLTS:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:SLTS:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:SLTS:1:SOLNSWITCH")
}

record(seq, "MGNT:SLTS:1:SOLNSWITCH") {
  field(DOL1, "MGNT:SLTS:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:SLTS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTS:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTS:1:SOLNCTRL")
}

record(seq, "MGNT:SLTS:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:SLTS:1:ALLSTAR")
  field(LNK1, "MGNT:SLTS:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:SLTS:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTS:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTS:1:SOLNCTRL",20,10,0,0,"MGNT:SLTS:1:SOLNCTRL")
#! Field("MGNT:SLTS:1:SOLNCTRL.FLNK",16777215,1,"MGNT:SLTS:1:SOLNCTRL.FLNK")
#! Link("MGNT:SLTS:1:SOLNCTRL.FLNK","MGNT:SLTS:1:SOLNSWITCH")
#! Field("MGNT:SLTS:1:SOLNCTRL.FFVL",16777215,1,"MGNT:SLTS:1:SOLNCTRL.FFVL")
#! Record("MGNT:SLTS:1:SOLNSWITCH",460,322,0,0,"MGNT:SLTS:1:SOLNSWITCH")
#! Field("MGNT:SLTS:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:SLTS:1:SOLNSWITCH.DOL1")
#! Link("MGNT:SLTS:1:SOLNSWITCH.DOL1","MGNT:SLTS:1:SOLNCTRL.FFVL")
#! Field("MGNT:SLTS:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:SLTS:1:SOLNSWITCH.LNK1")
#! Field("MGNT:SLTS:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:SLTS:1:SOLNSWITCH.FLNK")
#! Record("MGNT:SLTS:1:ALLSOLNSGO",240,96,0,0,"MGNT:SLTS:1:ALLSOLNSGO")
#! Field("MGNT:SLTS:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:SLTS:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:SLTS:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:SLTS:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:SLTS:1:ALLSOLNSGO.LNK1","MGNT:SLTS:1:ALLSOLNS.VAL")
#! Record("MGNT:SLTS:1:ALLSOLNS",540,102,0,0,"MGNT:SLTS:1:ALLSOLNS")
#! Field("MGNT:SLTS:1:ALLSOLNS.VAL",16777215,0,"MGNT:SLTS:1:ALLSOLNS.VAL")
#! Field("MGNT:SLTS:1:ALLSOLNS.FLNK",16777215,1,"MGNT:SLTS:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:SLTS:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:SLTS:1:KICKSWITCH")
}

record(seq, "MGNT:SLTS:1:KICKSWITCH") {
  field(DOL1, "MGNT:SLTS:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:SLTS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTS:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTS:1:KICKCTRL")
}

record(seq, "MGNT:SLTS:1:ALLKICKSGO") {
  field(DOL1, "MGNT:SLTS:1:ALLSTAR")
  field(LNK1, "MGNT:SLTS:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:SLTS:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTS:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTS:1:KICKCTRL",20,10,0,0,"MGNT:SLTS:1:KICKCTRL")
#! Field("MGNT:SLTS:1:KICKCTRL.FLNK",16777215,1,"MGNT:SLTS:1:KICKCTRL.FLNK")
#! Link("MGNT:SLTS:1:KICKCTRL.FLNK","MGNT:SLTS:1:KICKSWITCH")
#! Field("MGNT:SLTS:1:KICKCTRL.FFVL",16777215,1,"MGNT:SLTS:1:KICKCTRL.FFVL")
#! Record("MGNT:SLTS:1:KICKSWITCH",460,322,0,0,"MGNT:SLTS:1:KICKSWITCH")
#! Field("MGNT:SLTS:1:KICKSWITCH.DOL1",16777215,0,"MGNT:SLTS:1:KICKSWITCH.DOL1")
#! Link("MGNT:SLTS:1:KICKSWITCH.DOL1","MGNT:SLTS:1:KICKCTRL.FFVL")
#! Field("MGNT:SLTS:1:KICKSWITCH.LNK1",16777215,1,"MGNT:SLTS:1:KICKSWITCH.LNK1")
#! Field("MGNT:SLTS:1:KICKSWITCH.FLNK",16777215,1,"MGNT:SLTS:1:KICKSWITCH.FLNK")
#! Record("MGNT:SLTS:1:ALLKICKSGO",240,96,0,0,"MGNT:SLTS:1:ALLKICKSGO")
#! Field("MGNT:SLTS:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:SLTS:1:ALLKICKSGO.DOL1")
#! Field("MGNT:SLTS:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:SLTS:1:ALLKICKSGO.LNK1")
#! Link("MGNT:SLTS:1:ALLKICKSGO.LNK1","MGNT:SLTS:1:ALLKICKS.VAL")
#! Record("MGNT:SLTS:1:ALLKICKS",540,102,0,0,"MGNT:SLTS:1:ALLKICKS")
#! Field("MGNT:SLTS:1:ALLKICKS.VAL",16777215,0,"MGNT:SLTS:1:ALLKICKS.VAL")
#! Field("MGNT:SLTS:1:ALLKICKS.FLNK",16777215,1,"MGNT:SLTS:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:SLTS:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:SLTS:1:SEXTSWITCH")
}

record(seq, "MGNT:SLTS:1:SEXTSWITCH") {
  field(DOL1, "MGNT:SLTS:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:SLTS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTS:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTS:1:SEXTCTRL")
}

record(seq, "MGNT:SLTS:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:SLTS:1:ALLSTAR")
  field(LNK1, "MGNT:SLTS:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:SLTS:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTS:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTS:1:SEXTCTRL",20,10,0,0,"MGNT:SLTS:1:SEXTCTRL")
#! Field("MGNT:SLTS:1:SEXTCTRL.FLNK",16777215,1,"MGNT:SLTS:1:SEXTCTRL.FLNK")
#! Link("MGNT:SLTS:1:SEXTCTRL.FLNK","MGNT:SLTS:1:SEXTSWITCH")
#! Field("MGNT:SLTS:1:SEXTCTRL.FFVL",16777215,1,"MGNT:SLTS:1:SEXTCTRL.FFVL")
#! Record("MGNT:SLTS:1:SEXTSWITCH",460,322,0,0,"MGNT:SLTS:1:SEXTSWITCH")
#! Field("MGNT:SLTS:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:SLTS:1:SEXTSWITCH.DOL1")
#! Link("MGNT:SLTS:1:SEXTSWITCH.DOL1","MGNT:SLTS:1:SEXTCTRL.FFVL")
#! Field("MGNT:SLTS:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:SLTS:1:SEXTSWITCH.LNK1")
#! Field("MGNT:SLTS:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:SLTS:1:SEXTSWITCH.FLNK")
#! Record("MGNT:SLTS:1:ALLSEXTSGO",240,96,0,0,"MGNT:SLTS:1:ALLSEXTSGO")
#! Field("MGNT:SLTS:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:SLTS:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:SLTS:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:SLTS:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:SLTS:1:ALLSEXTSGO.LNK1","MGNT:SLTS:1:ALLSEXTS.VAL")
#! Record("MGNT:SLTS:1:ALLSEXTS",540,102,0,0,"MGNT:SLTS:1:ALLSEXTS")
#! Field("MGNT:SLTS:1:ALLSEXTS.VAL",16777215,0,"MGNT:SLTS:1:ALLSEXTS.VAL")
#! Field("MGNT:SLTS:1:ALLSEXTS.FLNK",16777215,1,"MGNT:SLTS:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:SLTD:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:SLTD:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:SLTD:1:CTRL CA PP")
  field(LNK2, "MGNT:SLTD:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:SLTD:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:SLTD:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:SLTD:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:SLTD:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:SLTD:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:SLTD:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:SLTD:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:SLTD:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:SLTD:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:SLTD:1:ALLSWITCH")
}

record(seq, "MGNT:SLTD:1:ALLSWITCH") {
  field(DOL1, "MGNT:SLTD:1:CTRL.FFVL")
  field(LNK1, "MGNT:SLTD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTD:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTD:1:CTRL")
}

record(bo, "MGNT:SLTD:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:SLTD:1:ALLSTARGO")
}

record(fanout, "MGNT:SLTD:1:ALLSTARGO") {
  field(LNK1, "MGNT:SLTD:1:ALLBENDSGO")
  field(LNK2, "MGNT:SLTD:1:ALLBTRMSGO")
  field(LNK3, "MGNT:SLTD:1:ALLLGPSSGO")
  field(LNK4, "MGNT:SLTD:1:ALLQUADSGO")
  field(LNK5, "MGNT:SLTD:1:ALLXCORSGO")
  field(LNK6, "MGNT:SLTD:1:ALLYCORSGO")
  field(FLNK, "MGNT:SLTD:1:ALLSTARGO_2")
}
record(fanout, "MGNT:SLTD:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:SLTD:1:ALLSOLNSGO")
  field(LNK2, "MGNT:SLTD:1:ALLKICKSGO")
  field(LNK3, "MGNT:SLTD:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:SLTD:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:SLTD:1:BENDSWITCH")
}

record(seq, "MGNT:SLTD:1:BENDSWITCH") {
  field(DOL1, "MGNT:SLTD:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:SLTD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTD:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTD:1:BENDCTRL")
}

record(seq, "MGNT:SLTD:1:ALLBENDSGO") {
  field(DOL1, "MGNT:SLTD:1:ALLSTAR")
  field(LNK1, "MGNT:SLTD:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:SLTD:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTD:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTD:1:BENDCTRL",20,10,0,0,"MGNT:SLTD:1:BENDCTRL")
#! Field("MGNT:SLTD:1:BENDCTRL.FLNK",16777215,1,"MGNT:SLTD:1:BENDCTRL.FLNK")
#! Link("MGNT:SLTD:1:BENDCTRL.FLNK","MGNT:SLTD:1:BENDSWITCH")
#! Field("MGNT:SLTD:1:BENDCTRL.FFVL",16777215,1,"MGNT:SLTD:1:BENDCTRL.FFVL")
#! Record("MGNT:SLTD:1:BENDSWITCH",460,322,0,0,"MGNT:SLTD:1:BENDSWITCH")
#! Field("MGNT:SLTD:1:BENDSWITCH.DOL1",16777215,0,"MGNT:SLTD:1:BENDSWITCH.DOL1")
#! Link("MGNT:SLTD:1:BENDSWITCH.DOL1","MGNT:SLTD:1:BENDCTRL.FFVL")
#! Field("MGNT:SLTD:1:BENDSWITCH.LNK1",16777215,1,"MGNT:SLTD:1:BENDSWITCH.LNK1")
#! Field("MGNT:SLTD:1:BENDSWITCH.FLNK",16777215,1,"MGNT:SLTD:1:BENDSWITCH.FLNK")
#! Record("MGNT:SLTD:1:ALLBENDSGO",240,96,0,0,"MGNT:SLTD:1:ALLBENDSGO")
#! Field("MGNT:SLTD:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:SLTD:1:ALLBENDSGO.DOL1")
#! Field("MGNT:SLTD:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:SLTD:1:ALLBENDSGO.LNK1")
#! Link("MGNT:SLTD:1:ALLBENDSGO.LNK1","MGNT:SLTD:1:ALLBENDS.VAL")
#! Record("MGNT:SLTD:1:ALLBENDS",540,102,0,0,"MGNT:SLTD:1:ALLBENDS")
#! Field("MGNT:SLTD:1:ALLBENDS.VAL",16777215,0,"MGNT:SLTD:1:ALLBENDS.VAL")
#! Field("MGNT:SLTD:1:ALLBENDS.FLNK",16777215,1,"MGNT:SLTD:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:SLTD:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:SLTD:1:BTRMSWITCH")
}

record(seq, "MGNT:SLTD:1:BTRMSWITCH") {
  field(DOL1, "MGNT:SLTD:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:SLTD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTD:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTD:1:BTRMCTRL")
}

record(seq, "MGNT:SLTD:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:SLTD:1:ALLSTAR")
  field(LNK1, "MGNT:SLTD:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:SLTD:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTD:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTD:1:BTRMCTRL",20,10,0,0,"MGNT:SLTD:1:BTRMCTRL")
#! Field("MGNT:SLTD:1:BTRMCTRL.FLNK",16777215,1,"MGNT:SLTD:1:BTRMCTRL.FLNK")
#! Link("MGNT:SLTD:1:BTRMCTRL.FLNK","MGNT:SLTD:1:BTRMSWITCH")
#! Field("MGNT:SLTD:1:BTRMCTRL.FFVL",16777215,1,"MGNT:SLTD:1:BTRMCTRL.FFVL")
#! Record("MGNT:SLTD:1:BTRMSWITCH",460,322,0,0,"MGNT:SLTD:1:BTRMSWITCH")
#! Field("MGNT:SLTD:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:SLTD:1:BTRMSWITCH.DOL1")
#! Link("MGNT:SLTD:1:BTRMSWITCH.DOL1","MGNT:SLTD:1:BTRMCTRL.FFVL")
#! Field("MGNT:SLTD:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:SLTD:1:BTRMSWITCH.LNK1")
#! Field("MGNT:SLTD:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:SLTD:1:BTRMSWITCH.FLNK")
#! Record("MGNT:SLTD:1:ALLBTRMSGO",240,96,0,0,"MGNT:SLTD:1:ALLBTRMSGO")
#! Field("MGNT:SLTD:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:SLTD:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:SLTD:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:SLTD:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:SLTD:1:ALLBTRMSGO.LNK1","MGNT:SLTD:1:ALLBTRMS.VAL")
#! Record("MGNT:SLTD:1:ALLBTRMS",540,102,0,0,"MGNT:SLTD:1:ALLBTRMS")
#! Field("MGNT:SLTD:1:ALLBTRMS.VAL",16777215,0,"MGNT:SLTD:1:ALLBTRMS.VAL")
#! Field("MGNT:SLTD:1:ALLBTRMS.FLNK",16777215,1,"MGNT:SLTD:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:SLTD:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:SLTD:1:LGPSSWITCH")
}

record(seq, "MGNT:SLTD:1:LGPSSWITCH") {
  field(DOL1, "MGNT:SLTD:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:SLTD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTD:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTD:1:LGPSCTRL")
}

record(seq, "MGNT:SLTD:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:SLTD:1:ALLSTAR")
  field(LNK1, "MGNT:SLTD:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:SLTD:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTD:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTD:1:LGPSCTRL",20,10,0,0,"MGNT:SLTD:1:LGPSCTRL")
#! Field("MGNT:SLTD:1:LGPSCTRL.FLNK",16777215,1,"MGNT:SLTD:1:LGPSCTRL.FLNK")
#! Link("MGNT:SLTD:1:LGPSCTRL.FLNK","MGNT:SLTD:1:LGPSSWITCH")
#! Field("MGNT:SLTD:1:LGPSCTRL.FFVL",16777215,1,"MGNT:SLTD:1:LGPSCTRL.FFVL")
#! Record("MGNT:SLTD:1:LGPSSWITCH",460,322,0,0,"MGNT:SLTD:1:LGPSSWITCH")
#! Field("MGNT:SLTD:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:SLTD:1:LGPSSWITCH.DOL1")
#! Link("MGNT:SLTD:1:LGPSSWITCH.DOL1","MGNT:SLTD:1:LGPSCTRL.FFVL")
#! Field("MGNT:SLTD:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:SLTD:1:LGPSSWITCH.LNK1")
#! Field("MGNT:SLTD:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:SLTD:1:LGPSSWITCH.FLNK")
#! Record("MGNT:SLTD:1:ALLLGPSSGO",240,96,0,0,"MGNT:SLTD:1:ALLLGPSSGO")
#! Field("MGNT:SLTD:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:SLTD:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:SLTD:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:SLTD:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:SLTD:1:ALLLGPSSGO.LNK1","MGNT:SLTD:1:ALLLGPSS.VAL")
#! Record("MGNT:SLTD:1:ALLLGPSS",540,102,0,0,"MGNT:SLTD:1:ALLLGPSS")
#! Field("MGNT:SLTD:1:ALLLGPSS.VAL",16777215,0,"MGNT:SLTD:1:ALLLGPSS.VAL")
#! Field("MGNT:SLTD:1:ALLLGPSS.FLNK",16777215,1,"MGNT:SLTD:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:SLTD:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:SLTD:1:QUADSWITCH")
}

record(seq, "MGNT:SLTD:1:QUADSWITCH") {
  field(DOL1, "MGNT:SLTD:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:SLTD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTD:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTD:1:QUADCTRL")
}

record(seq, "MGNT:SLTD:1:ALLQUADSGO") {
  field(DOL1, "MGNT:SLTD:1:ALLSTAR")
  field(LNK1, "MGNT:SLTD:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:SLTD:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTD:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTD:1:QUADCTRL",20,10,0,0,"MGNT:SLTD:1:QUADCTRL")
#! Field("MGNT:SLTD:1:QUADCTRL.FLNK",16777215,1,"MGNT:SLTD:1:QUADCTRL.FLNK")
#! Link("MGNT:SLTD:1:QUADCTRL.FLNK","MGNT:SLTD:1:QUADSWITCH")
#! Field("MGNT:SLTD:1:QUADCTRL.FFVL",16777215,1,"MGNT:SLTD:1:QUADCTRL.FFVL")
#! Record("MGNT:SLTD:1:QUADSWITCH",460,322,0,0,"MGNT:SLTD:1:QUADSWITCH")
#! Field("MGNT:SLTD:1:QUADSWITCH.DOL1",16777215,0,"MGNT:SLTD:1:QUADSWITCH.DOL1")
#! Link("MGNT:SLTD:1:QUADSWITCH.DOL1","MGNT:SLTD:1:QUADCTRL.FFVL")
#! Field("MGNT:SLTD:1:QUADSWITCH.LNK1",16777215,1,"MGNT:SLTD:1:QUADSWITCH.LNK1")
#! Field("MGNT:SLTD:1:QUADSWITCH.FLNK",16777215,1,"MGNT:SLTD:1:QUADSWITCH.FLNK")
#! Record("MGNT:SLTD:1:ALLQUADSGO",240,96,0,0,"MGNT:SLTD:1:ALLQUADSGO")
#! Field("MGNT:SLTD:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:SLTD:1:ALLQUADSGO.DOL1")
#! Field("MGNT:SLTD:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:SLTD:1:ALLQUADSGO.LNK1")
#! Link("MGNT:SLTD:1:ALLQUADSGO.LNK1","MGNT:SLTD:1:ALLQUADS.VAL")
#! Record("MGNT:SLTD:1:ALLQUADS",540,102,0,0,"MGNT:SLTD:1:ALLQUADS")
#! Field("MGNT:SLTD:1:ALLQUADS.VAL",16777215,0,"MGNT:SLTD:1:ALLQUADS.VAL")
#! Field("MGNT:SLTD:1:ALLQUADS.FLNK",16777215,1,"MGNT:SLTD:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:SLTD:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:SLTD:1:XCORSWITCH")
}

record(seq, "MGNT:SLTD:1:XCORSWITCH") {
  field(DOL1, "MGNT:SLTD:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:SLTD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTD:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTD:1:XCORCTRL")
}

record(seq, "MGNT:SLTD:1:ALLXCORSGO") {
  field(DOL1, "MGNT:SLTD:1:ALLSTAR")
  field(LNK1, "MGNT:SLTD:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:SLTD:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTD:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTD:1:XCORCTRL",20,10,0,0,"MGNT:SLTD:1:XCORCTRL")
#! Field("MGNT:SLTD:1:XCORCTRL.FLNK",16777215,1,"MGNT:SLTD:1:XCORCTRL.FLNK")
#! Link("MGNT:SLTD:1:XCORCTRL.FLNK","MGNT:SLTD:1:XCORSWITCH")
#! Field("MGNT:SLTD:1:XCORCTRL.FFVL",16777215,1,"MGNT:SLTD:1:XCORCTRL.FFVL")
#! Record("MGNT:SLTD:1:XCORSWITCH",460,322,0,0,"MGNT:SLTD:1:XCORSWITCH")
#! Field("MGNT:SLTD:1:XCORSWITCH.DOL1",16777215,0,"MGNT:SLTD:1:XCORSWITCH.DOL1")
#! Link("MGNT:SLTD:1:XCORSWITCH.DOL1","MGNT:SLTD:1:XCORCTRL.FFVL")
#! Field("MGNT:SLTD:1:XCORSWITCH.LNK1",16777215,1,"MGNT:SLTD:1:XCORSWITCH.LNK1")
#! Field("MGNT:SLTD:1:XCORSWITCH.FLNK",16777215,1,"MGNT:SLTD:1:XCORSWITCH.FLNK")
#! Record("MGNT:SLTD:1:ALLXCORSGO",240,96,0,0,"MGNT:SLTD:1:ALLXCORSGO")
#! Field("MGNT:SLTD:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:SLTD:1:ALLXCORSGO.DOL1")
#! Field("MGNT:SLTD:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:SLTD:1:ALLXCORSGO.LNK1")
#! Link("MGNT:SLTD:1:ALLXCORSGO.LNK1","MGNT:SLTD:1:ALLXCORS.VAL")
#! Record("MGNT:SLTD:1:ALLXCORS",540,102,0,0,"MGNT:SLTD:1:ALLXCORS")
#! Field("MGNT:SLTD:1:ALLXCORS.VAL",16777215,0,"MGNT:SLTD:1:ALLXCORS.VAL")
#! Field("MGNT:SLTD:1:ALLXCORS.FLNK",16777215,1,"MGNT:SLTD:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:SLTD:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:SLTD:1:YCORSWITCH")
}

record(seq, "MGNT:SLTD:1:YCORSWITCH") {
  field(DOL1, "MGNT:SLTD:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:SLTD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTD:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTD:1:YCORCTRL")
}

record(seq, "MGNT:SLTD:1:ALLYCORSGO") {
  field(DOL1, "MGNT:SLTD:1:ALLSTAR")
  field(LNK1, "MGNT:SLTD:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:SLTD:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTD:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTD:1:YCORCTRL",20,10,0,0,"MGNT:SLTD:1:YCORCTRL")
#! Field("MGNT:SLTD:1:YCORCTRL.FLNK",16777215,1,"MGNT:SLTD:1:YCORCTRL.FLNK")
#! Link("MGNT:SLTD:1:YCORCTRL.FLNK","MGNT:SLTD:1:YCORSWITCH")
#! Field("MGNT:SLTD:1:YCORCTRL.FFVL",16777215,1,"MGNT:SLTD:1:YCORCTRL.FFVL")
#! Record("MGNT:SLTD:1:YCORSWITCH",460,322,0,0,"MGNT:SLTD:1:YCORSWITCH")
#! Field("MGNT:SLTD:1:YCORSWITCH.DOL1",16777215,0,"MGNT:SLTD:1:YCORSWITCH.DOL1")
#! Link("MGNT:SLTD:1:YCORSWITCH.DOL1","MGNT:SLTD:1:YCORCTRL.FFVL")
#! Field("MGNT:SLTD:1:YCORSWITCH.LNK1",16777215,1,"MGNT:SLTD:1:YCORSWITCH.LNK1")
#! Field("MGNT:SLTD:1:YCORSWITCH.FLNK",16777215,1,"MGNT:SLTD:1:YCORSWITCH.FLNK")
#! Record("MGNT:SLTD:1:ALLYCORSGO",240,96,0,0,"MGNT:SLTD:1:ALLYCORSGO")
#! Field("MGNT:SLTD:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:SLTD:1:ALLYCORSGO.DOL1")
#! Field("MGNT:SLTD:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:SLTD:1:ALLYCORSGO.LNK1")
#! Link("MGNT:SLTD:1:ALLYCORSGO.LNK1","MGNT:SLTD:1:ALLYCORS.VAL")
#! Record("MGNT:SLTD:1:ALLYCORS",540,102,0,0,"MGNT:SLTD:1:ALLYCORS")
#! Field("MGNT:SLTD:1:ALLYCORS.VAL",16777215,0,"MGNT:SLTD:1:ALLYCORS.VAL")
#! Field("MGNT:SLTD:1:ALLYCORS.FLNK",16777215,1,"MGNT:SLTD:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:SLTD:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:SLTD:1:SOLNSWITCH")
}

record(seq, "MGNT:SLTD:1:SOLNSWITCH") {
  field(DOL1, "MGNT:SLTD:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:SLTD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTD:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTD:1:SOLNCTRL")
}

record(seq, "MGNT:SLTD:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:SLTD:1:ALLSTAR")
  field(LNK1, "MGNT:SLTD:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:SLTD:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTD:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTD:1:SOLNCTRL",20,10,0,0,"MGNT:SLTD:1:SOLNCTRL")
#! Field("MGNT:SLTD:1:SOLNCTRL.FLNK",16777215,1,"MGNT:SLTD:1:SOLNCTRL.FLNK")
#! Link("MGNT:SLTD:1:SOLNCTRL.FLNK","MGNT:SLTD:1:SOLNSWITCH")
#! Field("MGNT:SLTD:1:SOLNCTRL.FFVL",16777215,1,"MGNT:SLTD:1:SOLNCTRL.FFVL")
#! Record("MGNT:SLTD:1:SOLNSWITCH",460,322,0,0,"MGNT:SLTD:1:SOLNSWITCH")
#! Field("MGNT:SLTD:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:SLTD:1:SOLNSWITCH.DOL1")
#! Link("MGNT:SLTD:1:SOLNSWITCH.DOL1","MGNT:SLTD:1:SOLNCTRL.FFVL")
#! Field("MGNT:SLTD:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:SLTD:1:SOLNSWITCH.LNK1")
#! Field("MGNT:SLTD:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:SLTD:1:SOLNSWITCH.FLNK")
#! Record("MGNT:SLTD:1:ALLSOLNSGO",240,96,0,0,"MGNT:SLTD:1:ALLSOLNSGO")
#! Field("MGNT:SLTD:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:SLTD:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:SLTD:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:SLTD:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:SLTD:1:ALLSOLNSGO.LNK1","MGNT:SLTD:1:ALLSOLNS.VAL")
#! Record("MGNT:SLTD:1:ALLSOLNS",540,102,0,0,"MGNT:SLTD:1:ALLSOLNS")
#! Field("MGNT:SLTD:1:ALLSOLNS.VAL",16777215,0,"MGNT:SLTD:1:ALLSOLNS.VAL")
#! Field("MGNT:SLTD:1:ALLSOLNS.FLNK",16777215,1,"MGNT:SLTD:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:SLTD:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:SLTD:1:KICKSWITCH")
}

record(seq, "MGNT:SLTD:1:KICKSWITCH") {
  field(DOL1, "MGNT:SLTD:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:SLTD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTD:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTD:1:KICKCTRL")
}

record(seq, "MGNT:SLTD:1:ALLKICKSGO") {
  field(DOL1, "MGNT:SLTD:1:ALLSTAR")
  field(LNK1, "MGNT:SLTD:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:SLTD:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTD:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTD:1:KICKCTRL",20,10,0,0,"MGNT:SLTD:1:KICKCTRL")
#! Field("MGNT:SLTD:1:KICKCTRL.FLNK",16777215,1,"MGNT:SLTD:1:KICKCTRL.FLNK")
#! Link("MGNT:SLTD:1:KICKCTRL.FLNK","MGNT:SLTD:1:KICKSWITCH")
#! Field("MGNT:SLTD:1:KICKCTRL.FFVL",16777215,1,"MGNT:SLTD:1:KICKCTRL.FFVL")
#! Record("MGNT:SLTD:1:KICKSWITCH",460,322,0,0,"MGNT:SLTD:1:KICKSWITCH")
#! Field("MGNT:SLTD:1:KICKSWITCH.DOL1",16777215,0,"MGNT:SLTD:1:KICKSWITCH.DOL1")
#! Link("MGNT:SLTD:1:KICKSWITCH.DOL1","MGNT:SLTD:1:KICKCTRL.FFVL")
#! Field("MGNT:SLTD:1:KICKSWITCH.LNK1",16777215,1,"MGNT:SLTD:1:KICKSWITCH.LNK1")
#! Field("MGNT:SLTD:1:KICKSWITCH.FLNK",16777215,1,"MGNT:SLTD:1:KICKSWITCH.FLNK")
#! Record("MGNT:SLTD:1:ALLKICKSGO",240,96,0,0,"MGNT:SLTD:1:ALLKICKSGO")
#! Field("MGNT:SLTD:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:SLTD:1:ALLKICKSGO.DOL1")
#! Field("MGNT:SLTD:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:SLTD:1:ALLKICKSGO.LNK1")
#! Link("MGNT:SLTD:1:ALLKICKSGO.LNK1","MGNT:SLTD:1:ALLKICKS.VAL")
#! Record("MGNT:SLTD:1:ALLKICKS",540,102,0,0,"MGNT:SLTD:1:ALLKICKS")
#! Field("MGNT:SLTD:1:ALLKICKS.VAL",16777215,0,"MGNT:SLTD:1:ALLKICKS.VAL")
#! Field("MGNT:SLTD:1:ALLKICKS.FLNK",16777215,1,"MGNT:SLTD:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:SLTD:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:SLTD:1:SEXTSWITCH")
}

record(seq, "MGNT:SLTD:1:SEXTSWITCH") {
  field(DOL1, "MGNT:SLTD:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:SLTD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SLTD:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SLTD:1:SEXTCTRL")
}

record(seq, "MGNT:SLTD:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:SLTD:1:ALLSTAR")
  field(LNK1, "MGNT:SLTD:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:SLTD:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SLTD:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SLTD:1:SEXTCTRL",20,10,0,0,"MGNT:SLTD:1:SEXTCTRL")
#! Field("MGNT:SLTD:1:SEXTCTRL.FLNK",16777215,1,"MGNT:SLTD:1:SEXTCTRL.FLNK")
#! Link("MGNT:SLTD:1:SEXTCTRL.FLNK","MGNT:SLTD:1:SEXTSWITCH")
#! Field("MGNT:SLTD:1:SEXTCTRL.FFVL",16777215,1,"MGNT:SLTD:1:SEXTCTRL.FFVL")
#! Record("MGNT:SLTD:1:SEXTSWITCH",460,322,0,0,"MGNT:SLTD:1:SEXTSWITCH")
#! Field("MGNT:SLTD:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:SLTD:1:SEXTSWITCH.DOL1")
#! Link("MGNT:SLTD:1:SEXTSWITCH.DOL1","MGNT:SLTD:1:SEXTCTRL.FFVL")
#! Field("MGNT:SLTD:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:SLTD:1:SEXTSWITCH.LNK1")
#! Field("MGNT:SLTD:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:SLTD:1:SEXTSWITCH.FLNK")
#! Record("MGNT:SLTD:1:ALLSEXTSGO",240,96,0,0,"MGNT:SLTD:1:ALLSEXTSGO")
#! Field("MGNT:SLTD:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:SLTD:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:SLTD:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:SLTD:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:SLTD:1:ALLSEXTSGO.LNK1","MGNT:SLTD:1:ALLSEXTS.VAL")
#! Record("MGNT:SLTD:1:ALLSEXTS",540,102,0,0,"MGNT:SLTD:1:ALLSEXTS")
#! Field("MGNT:SLTD:1:ALLSEXTS.VAL",16777215,0,"MGNT:SLTD:1:ALLSEXTS.VAL")
#! Field("MGNT:SLTD:1:ALLSEXTS.FLNK",16777215,1,"MGNT:SLTD:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(seq, "MGNT:BSY0:1:CU:ALLSOLNSSEL") {
}
record(seq, "MGNT:BSY0:1:CU:ALLKICKSSEL") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLKICKS")
  field(LNK1, "KICK:CLTS:185:SELECT CPP NMS")
}
record(seq, "MGNT:BSY0:1:CU:ALLSEXTSSEL") {
}

record(seq, "MGNT:BSY0:1:CU:ALLBENDSSEL") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLBENDS")
  field(DOL2, "MGNT:BSY0:1:CU:ALLBENDS")
  field(DOL3, "MGNT:BSY0:1:CU:ALLBENDS")
  field(DOL4, "MGNT:BSY0:1:CU:ALLBENDS")
  field(LNK1, "BEND:CLTS:180:SELECT CPP NMS")
  field(LNK2, "BEND:CLTS:280:SELECT CPP NMS")
  field(LNK3, "BEND:CLTS:505:SELECT CPP NMS")
  field(LNK4, "BEND:CLTS:765:SELECT CPP NMS")
}

record(seq, "MGNT:BSY0:1:CU:ALLBTRMSSEL") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLBTRMS")
  field(DOL2, "MGNT:BSY0:1:CU:ALLBTRMS")
  field(LNK1, "BTRM:CLTS:280:SELECT CPP NMS")
  field(LNK2, "BTRM:CLTS:765:SELECT CPP NMS")
}

record(seq, "MGNT:BSY0:1:CU:ALLLGPSSSEL") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLLGPSS")
  field(DOL2, "MGNT:BSY0:1:CU:ALLLGPSS")
  field(DOL3, "MGNT:BSY0:1:CU:ALLLGPSS")
  field(LNK1, "LGPS:BSY0:1:SELECT CPP NMS")
  field(LNK2, "LGPS:BSY0:2:SELECT CPP NMS")
  field(LNK3, "LGPS:BSY0:3:SELECT CPP NMS")
}

record(seq, "MGNT:BSY0:1:CU:ALLQUADSSEL") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLQUADS")
  field(DOL2, "MGNT:BSY0:1:CU:ALLQUADS")
  field(DOL3, "MGNT:BSY0:1:CU:ALLQUADS")
  field(DOL4, "MGNT:BSY0:1:CU:ALLQUADS")
  field(DOL5, "MGNT:BSY0:1:CU:ALLQUADS")
  field(DOL6, "MGNT:BSY0:1:CU:ALLQUADS")
  field(DOL7, "MGNT:BSY0:1:CU:ALLQUADS")
  field(DOL8, "MGNT:BSY0:1:CU:ALLQUADS")
  field(DOL9, "MGNT:BSY0:1:CU:ALLQUADS")
  field(LNK1, "QUAD:CLTH:140:SELECT CPP NMS")
  field(LNK2, "QUAD:CLTH:170:SELECT CPP NMS")
  field(LNK3, "QUAD:CLTS:420:SELECT CPP NMS")
  field(LNK4, "QUAD:CLTS:450:SELECT CPP NMS")
  field(LNK5, "QUAD:CLTS:470:SELECT CPP NMS")
  field(LNK6, "QUAD:CLTS:500:SELECT CPP NMS")
  field(LNK7, "QUAD:CLTS:510:SELECT CPP NMS")
  field(LNK8, "QUAD:CLTS:590:SELECT CPP NMS")
  field(LNK9, "QUAD:CLTS:620:SELECT CPP NMS")
}

record(seq, "MGNT:BSY0:1:CU:ALLXCORSSEL") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLXCORS")
  field(DOL2, "MGNT:BSY0:1:CU:ALLXCORS")
  field(DOL3, "MGNT:BSY0:1:CU:ALLXCORS")
  field(DOL4, "MGNT:BSY0:1:CU:ALLXCORS")
  field(DOL5, "MGNT:BSY0:1:CU:ALLXCORS")
  field(LNK1, "XCOR:CLTH:168:SELECT CPP NMS")
  field(LNK2, "XCOR:CLTS:426:SELECT CPP NMS")
  field(LNK3, "XCOR:CLTS:504:SELECT CPP NMS")
  field(LNK4, "XCOR:CLTS:542:SELECT CPP NMS")
  field(LNK5, "XCOR:CLTS:614:SELECT CPP NMS")
}

record(seq, "MGNT:BSY0:1:CU:ALLYCORSSEL") {
  field(DOL1, "MGNT:BSY0:1:CU:ALLYCORS")
  field(DOL2, "MGNT:BSY0:1:CU:ALLYCORS")
  field(DOL3, "MGNT:BSY0:1:CU:ALLYCORS")
  field(DOL4, "MGNT:BSY0:1:CU:ALLYCORS")
  field(DOL5, "MGNT:BSY0:1:CU:ALLYCORS")
  field(DOL6, "MGNT:BSY0:1:CU:ALLYCORS")
  field(LNK1, "YCOR:CLTH:133:SELECT CPP NMS")
  field(LNK2, "YCOR:CLTS:453:SELECT CPP NMS")
  field(LNK3, "YCOR:CLTS:471:SELECT CPP NMS")
  field(LNK4, "YCOR:CLTS:533:SELECT CPP NMS")
  field(LNK5, "YCOR:CLTS:573:SELECT CPP NMS")
  field(LNK6, "YCOR:CLTS:597:SELECT CPP NMS")
}

record(seq, "MGNT:BSY0:1:CU:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(LNK1, "MGNT:BSY0:1:CU:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:BSY0:1:CU:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:BSY0:1:CU:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:BSY0:1:CU:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:BSY0:1:CU:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:BSY0:1:CU:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:BSY0:1:CU:LGPSFUNCGO.PROC")
  field(FLNK, "MGNT:BSY0:1:CU:ALLFUNCGO2")
}
record(seq, "MGNT:BSY0:1:CU:ALLFUNCGO2") {
  field(DESC, "Process CTRL func")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:BSY0:1:CU:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:BSY0:1:CU:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:BSY0:1:CU:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:BSY0:1:CU:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:BSY0:1:CU:CTRLCLEAR")
}

record(fanout, "MGNT:BSY0:1:CU:SOLNFUNCGO") {
  field(DESC, "Process SOLN CTRL func")
  field(FLNK, "MGNT:BSY0:1:CU:CTRLCLEAR")
}
record(fanout, "MGNT:BSY0:1:CU:KICKFUNCGO") {
  field(DESC, "Process KICK CTRL func")
  field(LNK1, "KICK:CLTS:185:ALLFUNCGO")
  field(FLNK, "MGNT:BSY0:1:CU:CTRLCLEAR")
}
record(fanout, "MGNT:BSY0:1:CU:SEXTFUNCGO") {
  field(DESC, "Process SEXT CTRL func")
  field(FLNK, "MGNT:BSY0:1:CU:CTRLCLEAR")
}
record(fanout, "MGNT:BSY0:1:CU:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(LNK1, "BEND:CLTS:180:ALLFUNCGO")
  field(LNK2, "BEND:CLTS:280:ALLFUNCGO")
  field(LNK3, "BEND:CLTS:505:ALLFUNCGO")
  field(LNK4, "BEND:CLTS:765:ALLFUNCGO")
  field(FLNK, "MGNT:BSY0:1:CU:CTRLCLEAR")
}

record(fanout, "MGNT:BSY0:1:CU:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(LNK1, "BTRM:CLTS:280:ALLFUNCGO")
  field(LNK2, "BTRM:CLTS:765:ALLFUNCGO")
  field(FLNK, "MGNT:BSY0:1:CU:CTRLCLEAR")
}

record(fanout, "MGNT:BSY0:1:CU:QUADFUNCGO") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:CLTH:140:ALLFUNCGO")
  field(LNK2, "QUAD:CLTH:170:ALLFUNCGO")
  field(LNK3, "QUAD:CLTS:420:ALLFUNCGO")
  field(LNK4, "QUAD:CLTS:450:ALLFUNCGO")
  field(LNK5, "QUAD:CLTS:470:ALLFUNCGO")
  field(LNK6, "QUAD:CLTS:500:ALLFUNCGO")
  field(FLNK, "MGNT:BSY0:1:CU:QUADFUNCGO_2")
}
record(fanout, "MGNT:BSY0:1:CU:QUADFUNCGO_2") {
  field(DESC, "Process QUAD CTRL func 2")
  field(LNK1, "QUAD:CLTS:510:ALLFUNCGO")
  field(LNK2, "QUAD:CLTS:590:ALLFUNCGO")
  field(LNK3, "QUAD:CLTS:620:ALLFUNCGO")
  field(FLNK, "MGNT:BSY0:1:CU:CTRLCLEAR")
}

record(fanout, "MGNT:BSY0:1:CU:XCORFUNCGO") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:CLTH:168:ALLFUNCGO")
  field(LNK2, "XCOR:CLTS:426:ALLFUNCGO")
  field(LNK3, "XCOR:CLTS:504:ALLFUNCGO")
  field(LNK4, "XCOR:CLTS:542:ALLFUNCGO")
  field(LNK5, "XCOR:CLTS:614:ALLFUNCGO")
  field(FLNK, "MGNT:BSY0:1:CU:CTRLCLEAR")
}

record(fanout, "MGNT:BSY0:1:CU:YCORFUNCGO") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:CLTH:133:ALLFUNCGO")
  field(LNK2, "YCOR:CLTS:453:ALLFUNCGO")
  field(LNK3, "YCOR:CLTS:471:ALLFUNCGO")
  field(LNK4, "YCOR:CLTS:533:ALLFUNCGO")
  field(LNK5, "YCOR:CLTS:573:ALLFUNCGO")
  field(LNK6, "YCOR:CLTS:597:ALLFUNCGO")
  field(FLNK, "MGNT:BSY0:1:CU:CTRLCLEAR")
}

record(fanout, "MGNT:BSY0:1:CU:LGPSFUNCGO") {
  field(DESC, "Process LGPS CTRL func")
  field(LNK1, "LGPS:BSY0:1:ALLFUNCGO")
  field(LNK2, "LGPS:BSY0:2:ALLFUNCGO")
  field(LNK3, "LGPS:BSY0:3:ALLFUNCGO")
  field(FLNK, "MGNT:BSY0:1:CU:CTRLCLEAR")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(seq, "MGNT:BSY0:1:ALLSOLNSSEL") {
}
record(seq, "MGNT:BSY0:1:ALLKICKSSEL") {
}
record(seq, "MGNT:BSY0:1:ALLSEXTSSEL") {
}
record(seq, "MGNT:BSY0:1:ALLBENDSSEL") {
}
record(seq, "MGNT:BSY0:1:ALLBTRMSSEL") {
}

record(seq, "MGNT:BSY0:1:ALLLGPSSSEL") {
  field(DESC, "Select All BSYH & BSYS LGPS")
  field(DOL1, "MGNT:BSY0:1:ALLLGPSS")
  field(DOL2, "MGNT:BSY0:1:ALLLGPSS")
  field(DOL3, "MGNT:BSY0:1:ALLLGPSS")
  field(DOL4, "MGNT:BSY0:1:ALLLGPSS")
  field(LNK1, "LGPS:BSY0:1:SELECT CPP NMS")
  field(LNK2, "LGPS:BSY0:2:SELECT CPP NMS")
  field(LNK3, "LGPS:BSY0:3:SELECT CPP NMS")
  field(LNK4, "LGPS:BSYS:1:SELECT CPP NMS")
}

record(seq, "MGNT:BSY0:1:ALLQUADSSEL") {
  field(DESC, "Select All BSYH & BSYS Quads")
  field(DOL1, "MGNT:BSY0:1:ALLQUADS")
  field(DOL2, "MGNT:BSY0:1:ALLQUADS")
  field(DOL3, "MGNT:BSY0:1:ALLQUADS")
  field(DOL4, "MGNT:BSY0:1:ALLQUADS")
  field(DOL5, "MGNT:BSY0:1:ALLQUADS")
  field(DOL6, "MGNT:BSY0:1:ALLQUADS")
  field(DOL7, "MGNT:BSY0:1:ALLQUADS")
  field(LNK1, "QUAD:BSYH:445:SELECT CPP NMS")
  field(LNK2, "QUAD:BSYH:465:SELECT CPP NMS")
  field(LNK3, "QUAD:BSYH:640:SELECT CPP NMS")
  field(LNK4, "QUAD:BSYH:735:SELECT CPP NMS")
  field(LNK5, "QUAD:BSYH:910:SELECT CPP NMS")
  field(LNK6, "QUAD:BSYS:820:SELECT CPP NMS")
  field(LNK7, "QUAD:BSYS:865:SELECT CPP NMS")
}

record(seq, "MGNT:BSY0:1:ALLXCORSSEL") {
  field(DOL1, "MGNT:BSY0:1:ALLXCORS")
  field(DOL2, "MGNT:BSY0:1:ALLXCORS")
  field(DOL3, "MGNT:BSY0:1:ALLXCORS")
  field(DOL4, "MGNT:BSY0:1:ALLXCORS")
  field(DOL5, "MGNT:BSY0:1:ALLXCORS")
  field(LNK1, "XCOR:BSYH:452:SELECT CPP NMS")
  field(LNK2, "XCOR:BSYH:642:SELECT CPP NMS")
  field(LNK3, "XCOR:BSYH:900:SELECT CPP NMS")
  field(LNK4, "XCOR:BSYS:822:SELECT CPP NMS")
  field(LNK5, "XCOR:BSYS:872:SELECT CPP NMS")
}

record(seq, "MGNT:BSY0:1:ALLYCORSSEL") {
  field(DOL1, "MGNT:BSY0:1:ALLYCORS")
  field(DOL2, "MGNT:BSY0:1:ALLYCORS")
  field(DOL3, "MGNT:BSY0:1:ALLYCORS")
  field(DOL4, "MGNT:BSY0:1:ALLYCORS")
  field(DOL5, "MGNT:BSY0:1:ALLYCORS")
  field(LNK1, "YCOR:BSYH:461:SELECT CPP NMS")
  field(LNK2, "YCOR:BSYH:739:SELECT CPP NMS")
  field(LNK3, "YCOR:BSYH:901:SELECT CPP NMS")
  field(LNK4, "YCOR:BSYS:823:SELECT CPP NMS")
  field(LNK5, "YCOR:BSYS:873:SELECT CPP NMS")
}

record(seq, "MGNT:BSY0:1:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(LNK1, "MGNT:BSY0:1:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:BSY0:1:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:BSY0:1:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:BSY0:1:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:BSY0:1:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:BSY0:1:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:BSY0:1:LGPSFUNCGO.PROC")
  field(FLNK, "MGNT:BSY0:1:ALLFUNCGO2")
}
record(seq, "MGNT:BSY0:1:ALLFUNCGO2") {
  field(DESC, "Process CTRL func")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:BSY0:1:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:BSY0:1:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:BSY0:1:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:BSY0:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:BSY0:1:CTRLCLEAR")
}

record(fanout, "MGNT:BSY0:1:SOLNFUNCGO") {
  field(DESC, "Process SOLN CTRL func")
  field(FLNK, "MGNT:BSY0:1:CTRLCLEAR")
}
record(fanout, "MGNT:BSY0:1:KICKFUNCGO") {
  field(DESC, "Process KICK CTRL func")
  field(FLNK, "MGNT:BSY0:1:CTRLCLEAR")
}
record(fanout, "MGNT:BSY0:1:SEXTFUNCGO") {
  field(DESC, "Process SEXT CTRL func")
  field(FLNK, "MGNT:BSY0:1:CTRLCLEAR")
}

record(fanout, "MGNT:BSY0:1:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(FLNK, "MGNT:BSY0:1:CTRLCLEAR")
}
record(fanout, "MGNT:BSY0:1:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(FLNK, "MGNT:BSY0:1:CTRLCLEAR")
}

record(fanout, "MGNT:BSY0:1:QUADFUNCGO") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:BSYH:445:ALLFUNCGO")
  field(LNK2, "QUAD:BSYH:465:ALLFUNCGO")
  field(LNK3, "QUAD:BSYH:640:ALLFUNCGO")
  field(LNK4, "QUAD:BSYH:735:ALLFUNCGO")
  field(LNK5, "QUAD:BSYH:910:ALLFUNCGO")
  field(LNK6, "QUAD:BSYS:820:ALLFUNCGO")
  field(FLNK, "MGNT:BSY0:1:QUADFUNCGO_2")
}
record(fanout, "MGNT:BSY0:1:QUADFUNCGO_2") {
  field(DESC, "Process QUAD CTRL func 2")
  field(LNK1, "QUAD:BSYS:865:ALLFUNCGO")
  field(FLNK, "MGNT:BSY0:1:CTRLCLEAR")
}

record(fanout, "MGNT:BSY0:1:XCORFUNCGO") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:BSYH:452:ALLFUNCGO")
  field(LNK2, "XCOR:BSYH:642:ALLFUNCGO")
  field(LNK3, "XCOR:BSYH:900:ALLFUNCGO")
  field(LNK4, "XCOR:BSYS:822:ALLFUNCGO")
  field(LNK5, "XCOR:BSYS:872:ALLFUNCGO")
  field(FLNK, "MGNT:BSY0:1:CTRLCLEAR")
}

record(fanout, "MGNT:BSY0:1:YCORFUNCGO") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:BSYH:461:ALLFUNCGO")
  field(LNK2, "YCOR:BSYH:739:ALLFUNCGO")
  field(LNK3, "YCOR:BSYH:901:ALLFUNCGO")
  field(LNK4, "YCOR:BSYS:823:ALLFUNCGO")
  field(LNK5, "YCOR:BSYS:873:ALLFUNCGO")
  field(FLNK, "MGNT:BSY0:1:CTRLCLEAR")
}

record(fanout, "MGNT:BSY0:1:LGPSFUNCGO") {
  field(DESC, "Process LGPS CTRL func")
  field(LNK1, "LGPS:BSY0:1:ALLFUNCGO")
  field(LNK2, "LGPS:BSY0:2:ALLFUNCGO")
  field(LNK3, "LGPS:BSY0:3:ALLFUNCGO")
  field(LNK4, "LGPS:BSYS:1:ALLFUNCGO")
  field(FLNK, "MGNT:BSY0:1:CTRLCLEAR")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(seq, "MGNT:SLTH:1:ALLSOLNSSEL") {
}
record(seq, "MGNT:SLTH:1:ALLKICKSSEL") {
}
record(seq, "MGNT:SLTH:1:ALLSEXTSSEL") {
}
record(seq, "MGNT:SLTH:1:ALLBTRMSSEL") {
  field(DOL1, "MGNT:SLTH:1:ALLBTRMS")
  field(LNK1, "BTRM:SLTH:435:SELECT CPP NMS")
}
record(seq, "MGNT:SLTH:1:ALLLGPSSSEL") {
}

record(seq, "MGNT:SLTH:1:ALLBENDSSEL") {
  field(DESC, "Select All SLTH BENDs")
  field(DOL1, "MGNT:SLTH:1:ALLBENDS")
  field(DOL2, "MGNT:SLTH:1:ALLBENDS")
  field(LNK1, "BEND:SLTH:145:SELECT CPP NMS")
  field(LNK2, "BEND:SLTH:435:SELECT CPP NMS")
}

record(seq, "MGNT:SLTH:1:ALLQUADSSEL") {
  field(DESC, "Select All SLTH QUADs")
  field(DOL1, "MGNT:SLTH:1:ALLQUADS")
  field(DOL2, "MGNT:SLTH:1:ALLQUADS")
  field(LNK1, "QUAD:SLTH:200:SELECT CPP NMS")
  field(LNK2, "QUAD:SLTH:220:SELECT CPP NMS")
}

record(seq, "MGNT:SLTH:1:ALLXCORSSEL") {
  field(DESC, "Select All SLTH XCORs")
  field(DOL1, "MGNT:SLTH:1:ALLXCORS")
  field(LNK1, "XCOR:SLTH:218:SELECT CPP NMS")
}

record(seq, "MGNT:SLTH:1:ALLYCORSSEL") {
  field(DESC, "Select All SLTH YCORs")
  field(DOL1, "MGNT:SLTH:1:ALLYCORS")
  field(LNK1, "YCOR:SLTH:201:SELECT CPP NMS")
}

record(seq, "MGNT:SLTH:1:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(LNK1, "MGNT:SLTH:1:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:SLTH:1:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:SLTH:1:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:SLTH:1:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:SLTH:1:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:SLTH:1:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:SLTH:1:LGPSFUNCGO.PROC")
  field(FLNK, "MGNT:SLTH:1:ALLFUNCGO2")
}
record(seq, "MGNT:SLTH:1:ALLFUNCGO2") {
  field(DESC, "Process CTRL func")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:SLTH:1:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:SLTH:1:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:SLTH:1:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:SLTH:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:SLTH:1:CTRLCLEAR")
}

record(fanout, "MGNT:SLTH:1:SOLNFUNCGO") {
  field(DESC, "Process SOLN CTRL func")
  field(FLNK, "MGNT:SLTH:1:CTRLCLEAR")
}
record(fanout, "MGNT:SLTH:1:KICKFUNCGO") {
  field(DESC, "Process KICK CTRL func")
  field(FLNK, "MGNT:SLTH:1:CTRLCLEAR")
}
record(fanout, "MGNT:SLTH:1:SEXTFUNCGO") {
  field(DESC, "Process SEXT CTRL func")
  field(FLNK, "MGNT:SLTH:1:CTRLCLEAR")
}

record(fanout, "MGNT:SLTH:1:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(LNK1, "BEND:SLTH:145:ALLFUNCGO")
  field(LNK2, "BEND:SLTH:435:ALLFUNCGO")
  field(FLNK, "MGNT:SLTH:1:CTRLCLEAR")
}
record(fanout, "MGNT:SLTH:1:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(LNK1, "BTRM:SLTH:435:ALLFUNCGO")
  field(FLNK, "MGNT:SLTH:1:CTRLCLEAR")
}
record(fanout, "MGNT:SLTH:1:QUADFUNCGO") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:SLTH:200:ALLFUNCGO")
  field(LNK2, "QUAD:SLTH:220:ALLFUNCGO")
  field(FLNK, "MGNT:SLTH:1:CTRLCLEAR")
}

record(fanout, "MGNT:SLTH:1:XCORFUNCGO") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:SLTH:218:ALLFUNCGO")
  field(FLNK, "MGNT:SLTH:1:CTRLCLEAR")
}

record(fanout, "MGNT:SLTH:1:YCORFUNCGO") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:SLTH:201:ALLFUNCGO")
  field(FLNK, "MGNT:SLTH:1:CTRLCLEAR")
}

record(fanout, "MGNT:SLTH:1:LGPSFUNCGO") {
  field(DESC, "Process LGPS CTRL func")
  field(FLNK, "MGNT:SLTH:1:CTRLCLEAR")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(seq, "MGNT:SLTS:1:ALLSOLNSSEL") {
}
record(seq, "MGNT:SLTS:1:ALLKICKSSEL") {
}
record(seq, "MGNT:SLTS:1:ALLSEXTSSEL") {
}
record(seq, "MGNT:SLTS:1:ALLBENDSSEL") {
}
record(seq, "MGNT:SLTS:1:ALLBTRMSSEL") {
}
record(seq, "MGNT:SLTS:1:ALLLGPSSSEL") {
  field(DESC, "Select All SLTS LGPSs")
  field(DOL1, "MGNT:SLTS:1:ALLLGPSS")
  field(LNK1, "LGPS:SLTS:1:SELECT CPP NMS")
}
record(seq, "MGNT:SLTS:1:ALLQUADSSEL") {
  field(DESC, "Select All SLTS QUADs")
  field(DOL1, "MGNT:SLTS:1:ALLQUADS")
  field(DOL2, "MGNT:SLTS:1:ALLQUADS")
  field(DOL3, "MGNT:SLTS:1:ALLQUADS")
  field(DOL4, "MGNT:SLTS:1:ALLQUADS")
  field(LNK1, "QUAD:SLTS:150:SELECT CPP NMS")
  field(LNK2, "QUAD:SLTS:180:SELECT CPP NMS")
  field(LNK3, "QUAD:SLTS:430:SELECT CPP NMS")
  field(LNK4, "QUAD:SLTS:460:SELECT CPP NMS")
}

record(seq, "MGNT:SLTS:1:ALLXCORSSEL") {
  field(DESC, "Select All SLTS XCORs")
  field(DOL1, "MGNT:SLTS:1:ALLXCORS")
  field(DOL2, "MGNT:SLTS:1:ALLXCORS")
  field(DOL3, "MGNT:SLTS:1:ALLXCORS")
  field(LNK1, "XCOR:SLTS:182:SELECT CPP NMS")
  field(LNK2, "XCOR:SLTS:442:SELECT CPP NMS")
  field(LNK3, "XCOR:SLTS:468:SELECT CPP NMS")
}

record(seq, "MGNT:SLTS:1:ALLYCORSSEL") {
  field(DESC, "Select All SLTS YCORs")
  field(DOL1, "MGNT:SLTS:1:ALLYCORS")
  field(DOL2, "MGNT:SLTS:1:ALLYCORS")
  field(DOL3, "MGNT:SLTS:1:ALLYCORS")
  field(LNK1, "YCOR:SLTS:183:SELECT CPP NMS")
  field(LNK2, "YCOR:SLTS:443:SELECT CPP NMS")
  field(LNK3, "YCOR:SLTS:469:SELECT CPP NMS")
}

record(seq, "MGNT:SLTS:1:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(LNK1, "MGNT:SLTS:1:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:SLTS:1:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:SLTS:1:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:SLTS:1:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:SLTS:1:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:SLTS:1:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:SLTS:1:LGPSFUNCGO.PROC")
  field(FLNK, "MGNT:SLTS:1:ALLFUNCGO2")
}
record(seq, "MGNT:SLTS:1:ALLFUNCGO2") {
  field(DESC, "Process CTRL func")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:SLTS:1:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:SLTS:1:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:SLTS:1:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:SLTS:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:SLTS:1:CTRLCLEAR")
}

record(fanout, "MGNT:SLTS:1:SOLNFUNCGO") {
  field(DESC, "Process SOLN CTRL func")
  field(FLNK, "MGNT:SLTS:1:CTRLCLEAR")
}
record(fanout, "MGNT:SLTS:1:KICKFUNCGO") {
  field(DESC, "Process KICK CTRL func")
  field(FLNK, "MGNT:SLTS:1:CTRLCLEAR")
}
record(fanout, "MGNT:SLTS:1:SEXTFUNCGO") {
  field(DESC, "Process SEXT CTRL func")
  field(FLNK, "MGNT:SLTS:1:CTRLCLEAR")
}

record(fanout, "MGNT:SLTS:1:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(FLNK, "MGNT:SLTS:1:CTRLCLEAR")
}
record(fanout, "MGNT:SLTS:1:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(FLNK, "MGNT:SLTS:1:CTRLCLEAR")
}
record(fanout, "MGNT:SLTS:1:QUADFUNCGO") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:SLTS:150:ALLFUNCGO")
  field(LNK2, "QUAD:SLTS:180:ALLFUNCGO")
  field(LNK3, "QUAD:SLTS:430:ALLFUNCGO")
  field(LNK4, "QUAD:SLTS:460:ALLFUNCGO")
  field(FLNK, "MGNT:SLTS:1:CTRLCLEAR")
}

record(fanout, "MGNT:SLTS:1:XCORFUNCGO") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:SLTS:182:ALLFUNCGO")
  field(LNK2, "XCOR:SLTS:442:ALLFUNCGO")
  field(LNK3, "XCOR:SLTS:468:ALLFUNCGO")
  field(FLNK, "MGNT:SLTS:1:CTRLCLEAR")
}

record(fanout, "MGNT:SLTS:1:YCORFUNCGO") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:SLTS:183:ALLFUNCGO")
  field(LNK2, "YCOR:SLTS:443:ALLFUNCGO")
  field(LNK3, "YCOR:SLTS:469:ALLFUNCGO")
  field(FLNK, "MGNT:SLTS:1:CTRLCLEAR")
}

record(fanout, "MGNT:SLTS:1:LGPSFUNCGO") {
  field(DESC, "Process LGPS CTRL func")
  field(LNK1, "LGPS:SLTS:1:ALLFUNCGO")
  field(FLNK, "MGNT:SLTS:1:CTRLCLEAR")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(seq, "MGNT:SLTD:1:ALLSOLNSSEL") {
}
record(seq, "MGNT:SLTD:1:ALLKICKSSEL") {
}
record(seq, "MGNT:SLTD:1:ALLSEXTSSEL") {
}
record(seq, "MGNT:SLTD:1:ALLBENDSSEL") {
}
record(seq, "MGNT:SLTD:1:ALLBTRMSSEL") {
}
record(seq, "MGNT:SLTD:1:ALLLGPSSSEL") {
}
record(seq, "MGNT:SLTD:1:ALLQUADSSEL") {
}

record(seq, "MGNT:SLTD:1:ALLXCORSSEL") {
  field(DESC, "Select All SLTD XCORs")
  field(DOL1, "MGNT:SLTD:1:ALLXCORS")
  field(LNK1, "XCOR:SLTD:628:SELECT CPP NMS")
}

record(seq, "MGNT:SLTD:1:ALLYCORSSEL") {
  field(DESC, "Select All SLTD YCORs")
  field(DOL1, "MGNT:SLTD:1:ALLYCORS")
  field(LNK1, "YCOR:SLTD:631:SELECT CPP NMS")
}

record(seq, "MGNT:SLTD:1:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(LNK1, "MGNT:SLTD:1:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:SLTD:1:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:SLTD:1:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:SLTD:1:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:SLTD:1:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:SLTD:1:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:SLTD:1:LGPSFUNCGO.PROC")
  field(FLNK, "MGNT:SLTD:1:ALLFUNCGO2")
}
record(seq, "MGNT:SLTD:1:ALLFUNCGO2") {
  field(DESC, "Process CTRL func")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:SLTD:1:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:SLTD:1:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:SLTD:1:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:SLTD:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:SLTD:1:CTRLCLEAR")
}

record(fanout, "MGNT:SLTD:1:SOLNFUNCGO") {
  field(DESC, "Process SOLN CTRL func")
  field(FLNK, "MGNT:SLTD:1:CTRLCLEAR")
}
record(fanout, "MGNT:SLTD:1:KICKFUNCGO") {
  field(DESC, "Process KICK CTRL func")
  field(FLNK, "MGNT:SLTD:1:CTRLCLEAR")
}
record(fanout, "MGNT:SLTD:1:SEXTFUNCGO") {
  field(DESC, "Process SEXT CTRL func")
  field(FLNK, "MGNT:SLTD:1:CTRLCLEAR")
}

record(fanout, "MGNT:SLTD:1:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(FLNK, "MGNT:SLTD:1:CTRLCLEAR")
}
record(fanout, "MGNT:SLTD:1:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(FLNK, "MGNT:SLTD:1:CTRLCLEAR")
}
record(fanout, "MGNT:SLTD:1:QUADFUNCGO") {
  field(DESC, "Process QUAD CTRL func")
  field(FLNK, "MGNT:SLTD:1:CTRLCLEAR")
}

record(fanout, "MGNT:SLTD:1:XCORFUNCGO") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:SLTD:628:ALLFUNCGO")
  field(FLNK, "MGNT:SLTD:1:CTRLCLEAR")
}

record(fanout, "MGNT:SLTD:1:YCORFUNCGO") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:SLTD:631:ALLFUNCGO")
  field(FLNK, "MGNT:SLTD:1:CTRLCLEAR")
}

record(fanout, "MGNT:SLTD:1:LGPSFUNCGO") {
  field(DESC, "Process LGPS CTRL func")
  field(FLNK, "MGNT:SLTD:1:CTRLCLEAR")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:BSY0:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "LGPS:BSY0:1:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:BSY0:1:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:BSY0:1:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:BSY0:1:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:BSY0:1:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:BSY0:1:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:BSY0:1:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:BSY0:1:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:BSY0:1:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:BSY0:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:BSY0:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:BSY0:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:BSY0:1:EDES.PROC PP")
    field(LNK2, "LGPS:BSY0:1:EACT.PROC PP")
    field(LNK3, "LGPS:BSY0:1:EERR.DISA PP")
    field(LNK4, "LGPS:BSY0:1:ECON.PROC PP")
    field(LNK5, "LGPS:BSY0:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:BSY0:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:BSY0:1:BLEM.PROC PP")
    field(LNK8, "LGPS:BSY0:1:BMOD.PROC PP")
    field(LNK9, "LGPS:BSY0:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:BSY0:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:BSY0:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:BSY0:1:BMAX")
  field(DOL2, "LGPS:BSY0:1:BMAX")
  field(DOL3, "LGPS:BSY0:1:BMAX")
  field(DOL4, "LGPS:BSY0:1:BMIN")
  field(DOL5, "LGPS:BSY0:1:BMIN")
  field(DOL6, "LGPS:BSY0:1:BMIN")
  field(LNK1, "LGPS:BSY0:1:BMAGX.HOPR")
  field(LNK2, "LGPS:BSY0:1:BMAGY.HOPR")
  field(LNK3, "LGPS:BSY0:1:BLEM.HOPR")
  field(LNK4, "LGPS:BSY0:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:BSY0:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:BSY0:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:BSY0:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:BSY0:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:BSY0:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:BSY0:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:BSY0:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BSY0:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BSY0:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BSY0:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BSY0:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BSY0:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:BSY0:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:BSY0:1:EDES NPP MS")
  field(INPB, "LGPS:BSY0:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:BSY0:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "LGPS:BSY0:2:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:BSY0:2:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:BSY0:2:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:BSY0:2:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:BSY0:2:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:BSY0:2:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:BSY0:2:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:BSY0:2:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:BSY0:2:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:BSY0:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:BSY0:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:BSY0:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:BSY0:2:EDES.PROC PP")
    field(LNK2, "LGPS:BSY0:2:EACT.PROC PP")
    field(LNK3, "LGPS:BSY0:2:EERR.DISA PP")
    field(LNK4, "LGPS:BSY0:2:ECON.PROC PP")
    field(LNK5, "LGPS:BSY0:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:BSY0:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:BSY0:2:BLEM.PROC PP")
    field(LNK8, "LGPS:BSY0:2:BMOD.PROC PP")
    field(LNK9, "LGPS:BSY0:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:BSY0:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:BSY0:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:BSY0:2:BMAX")
  field(DOL2, "LGPS:BSY0:2:BMAX")
  field(DOL3, "LGPS:BSY0:2:BMAX")
  field(DOL4, "LGPS:BSY0:2:BMIN")
  field(DOL5, "LGPS:BSY0:2:BMIN")
  field(DOL6, "LGPS:BSY0:2:BMIN")
  field(LNK1, "LGPS:BSY0:2:BMAGX.HOPR")
  field(LNK2, "LGPS:BSY0:2:BMAGY.HOPR")
  field(LNK3, "LGPS:BSY0:2:BLEM.HOPR")
  field(LNK4, "LGPS:BSY0:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:BSY0:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:BSY0:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:BSY0:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:BSY0:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:BSY0:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:BSY0:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:BSY0:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BSY0:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BSY0:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BSY0:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BSY0:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BSY0:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:BSY0:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:BSY0:2:EDES NPP MS")
  field(INPB, "LGPS:BSY0:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:BSY0:3:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "LGPS:BSY0:3:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:BSY0:3:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:BSY0:3:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:BSY0:3:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:BSY0:3:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:BSY0:3:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:BSY0:3:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:BSY0:3:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:BSY0:3:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:BSY0:3:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:BSY0:3:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:BSY0:3:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:BSY0:3:EDES.PROC PP")
    field(LNK2, "LGPS:BSY0:3:EACT.PROC PP")
    field(LNK3, "LGPS:BSY0:3:EERR.DISA PP")
    field(LNK4, "LGPS:BSY0:3:ECON.PROC PP")
    field(LNK5, "LGPS:BSY0:3:BMAGX.PROC PP")
    field(LNK6, "LGPS:BSY0:3:BMAGY.PROC PP")
    field(LNK7, "LGPS:BSY0:3:BLEM.PROC PP")
    field(LNK8, "LGPS:BSY0:3:BMOD.PROC PP")
    field(LNK9, "LGPS:BSY0:3:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:BSY0:3:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:BSY0:3:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:BSY0:3:BMAX")
  field(DOL2, "LGPS:BSY0:3:BMAX")
  field(DOL3, "LGPS:BSY0:3:BMAX")
  field(DOL4, "LGPS:BSY0:3:BMIN")
  field(DOL5, "LGPS:BSY0:3:BMIN")
  field(DOL6, "LGPS:BSY0:3:BMIN")
  field(LNK1, "LGPS:BSY0:3:BMAGX.HOPR")
  field(LNK2, "LGPS:BSY0:3:BMAGY.HOPR")
  field(LNK3, "LGPS:BSY0:3:BLEM.HOPR")
  field(LNK4, "LGPS:BSY0:3:BMAGX.LOPR PP")
  field(LNK5, "LGPS:BSY0:3:BMAGY.LOPR PP")
  field(LNK6, "LGPS:BSY0:3:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:BSY0:3:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:BSY0:3:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:BSY0:3:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:BSY0:3:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:BSY0:3:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BSY0:3:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BSY0:3:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BSY0:3:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BSY0:3:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BSY0:3:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:BSY0:3:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:BSY0:3:EDES NPP MS")
  field(INPB, "LGPS:BSY0:3:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BSYH:445:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "QUAD:BSYH:445:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BSYH:445:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BSYH:445:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BSYH:445:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BSYH:445:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BSYH:445:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BSYH:445:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BSYH:445:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BSYH:445:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BSYH:445:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BSYH:445:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BSYH:445:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BSYH:445:EDES.PROC PP")
    field(LNK2, "QUAD:BSYH:445:EACT.PROC PP")
    field(LNK3, "QUAD:BSYH:445:EERR.DISA PP")
    field(LNK4, "QUAD:BSYH:445:ECON.PROC PP")
    field(LNK5, "QUAD:BSYH:445:BMAGX.PROC PP")
    field(LNK6, "QUAD:BSYH:445:BMAGY.PROC PP")
    field(LNK7, "QUAD:BSYH:445:BLEM.PROC PP")
    field(LNK8, "QUAD:BSYH:445:BMOD.PROC PP")
    field(LNK9, "QUAD:BSYH:445:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BSYH:445:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BSYH:445:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BSYH:445:BMAX")
  field(DOL2, "QUAD:BSYH:445:BMAX")
  field(DOL3, "QUAD:BSYH:445:BMAX")
  field(DOL4, "QUAD:BSYH:445:BMIN")
  field(DOL5, "QUAD:BSYH:445:BMIN")
  field(DOL6, "QUAD:BSYH:445:BMIN")
  field(LNK1, "QUAD:BSYH:445:BMAGX.HOPR")
  field(LNK2, "QUAD:BSYH:445:BMAGY.HOPR")
  field(LNK3, "QUAD:BSYH:445:BLEM.HOPR")
  field(LNK4, "QUAD:BSYH:445:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BSYH:445:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BSYH:445:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BSYH:445:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BSYH:445:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BSYH:445:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BSYH:445:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BSYH:445:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYH:445:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYH:445:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BSYH:445:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYH:445:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BSYH:445:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BSYH:445:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BSYH:445:EDES NPP MS")
  field(INPB, "QUAD:BSYH:445:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BSYH:465:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "QUAD:BSYH:465:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BSYH:465:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BSYH:465:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BSYH:465:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BSYH:465:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BSYH:465:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BSYH:465:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BSYH:465:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BSYH:465:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BSYH:465:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BSYH:465:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BSYH:465:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BSYH:465:EDES.PROC PP")
    field(LNK2, "QUAD:BSYH:465:EACT.PROC PP")
    field(LNK3, "QUAD:BSYH:465:EERR.DISA PP")
    field(LNK4, "QUAD:BSYH:465:ECON.PROC PP")
    field(LNK5, "QUAD:BSYH:465:BMAGX.PROC PP")
    field(LNK6, "QUAD:BSYH:465:BMAGY.PROC PP")
    field(LNK7, "QUAD:BSYH:465:BLEM.PROC PP")
    field(LNK8, "QUAD:BSYH:465:BMOD.PROC PP")
    field(LNK9, "QUAD:BSYH:465:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BSYH:465:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BSYH:465:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BSYH:465:BMAX")
  field(DOL2, "QUAD:BSYH:465:BMAX")
  field(DOL3, "QUAD:BSYH:465:BMAX")
  field(DOL4, "QUAD:BSYH:465:BMIN")
  field(DOL5, "QUAD:BSYH:465:BMIN")
  field(DOL6, "QUAD:BSYH:465:BMIN")
  field(LNK1, "QUAD:BSYH:465:BMAGX.HOPR")
  field(LNK2, "QUAD:BSYH:465:BMAGY.HOPR")
  field(LNK3, "QUAD:BSYH:465:BLEM.HOPR")
  field(LNK4, "QUAD:BSYH:465:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BSYH:465:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BSYH:465:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BSYH:465:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BSYH:465:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BSYH:465:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BSYH:465:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BSYH:465:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYH:465:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYH:465:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BSYH:465:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYH:465:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BSYH:465:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BSYH:465:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BSYH:465:EDES NPP MS")
  field(INPB, "QUAD:BSYH:465:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BSYH:640:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "QUAD:BSYH:640:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BSYH:640:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BSYH:640:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BSYH:640:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BSYH:640:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BSYH:640:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BSYH:640:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BSYH:640:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BSYH:640:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BSYH:640:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BSYH:640:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BSYH:640:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BSYH:640:EDES.PROC PP")
    field(LNK2, "QUAD:BSYH:640:EACT.PROC PP")
    field(LNK3, "QUAD:BSYH:640:EERR.DISA PP")
    field(LNK4, "QUAD:BSYH:640:ECON.PROC PP")
    field(LNK5, "QUAD:BSYH:640:BMAGX.PROC PP")
    field(LNK6, "QUAD:BSYH:640:BMAGY.PROC PP")
    field(LNK7, "QUAD:BSYH:640:BLEM.PROC PP")
    field(LNK8, "QUAD:BSYH:640:BMOD.PROC PP")
    field(LNK9, "QUAD:BSYH:640:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BSYH:640:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BSYH:640:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BSYH:640:BMAX")
  field(DOL2, "QUAD:BSYH:640:BMAX")
  field(DOL3, "QUAD:BSYH:640:BMAX")
  field(DOL4, "QUAD:BSYH:640:BMIN")
  field(DOL5, "QUAD:BSYH:640:BMIN")
  field(DOL6, "QUAD:BSYH:640:BMIN")
  field(LNK1, "QUAD:BSYH:640:BMAGX.HOPR")
  field(LNK2, "QUAD:BSYH:640:BMAGY.HOPR")
  field(LNK3, "QUAD:BSYH:640:BLEM.HOPR")
  field(LNK4, "QUAD:BSYH:640:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BSYH:640:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BSYH:640:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BSYH:640:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BSYH:640:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BSYH:640:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BSYH:640:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BSYH:640:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYH:640:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYH:640:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BSYH:640:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYH:640:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BSYH:640:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BSYH:640:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BSYH:640:EDES NPP MS")
  field(INPB, "QUAD:BSYH:640:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BSYH:735:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "QUAD:BSYH:735:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BSYH:735:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BSYH:735:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BSYH:735:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BSYH:735:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BSYH:735:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BSYH:735:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BSYH:735:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BSYH:735:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BSYH:735:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BSYH:735:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BSYH:735:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BSYH:735:EDES.PROC PP")
    field(LNK2, "QUAD:BSYH:735:EACT.PROC PP")
    field(LNK3, "QUAD:BSYH:735:EERR.DISA PP")
    field(LNK4, "QUAD:BSYH:735:ECON.PROC PP")
    field(LNK5, "QUAD:BSYH:735:BMAGX.PROC PP")
    field(LNK6, "QUAD:BSYH:735:BMAGY.PROC PP")
    field(LNK7, "QUAD:BSYH:735:BLEM.PROC PP")
    field(LNK8, "QUAD:BSYH:735:BMOD.PROC PP")
    field(LNK9, "QUAD:BSYH:735:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BSYH:735:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BSYH:735:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BSYH:735:BMAX")
  field(DOL2, "QUAD:BSYH:735:BMAX")
  field(DOL3, "QUAD:BSYH:735:BMAX")
  field(DOL4, "QUAD:BSYH:735:BMIN")
  field(DOL5, "QUAD:BSYH:735:BMIN")
  field(DOL6, "QUAD:BSYH:735:BMIN")
  field(LNK1, "QUAD:BSYH:735:BMAGX.HOPR")
  field(LNK2, "QUAD:BSYH:735:BMAGY.HOPR")
  field(LNK3, "QUAD:BSYH:735:BLEM.HOPR")
  field(LNK4, "QUAD:BSYH:735:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BSYH:735:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BSYH:735:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BSYH:735:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BSYH:735:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BSYH:735:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BSYH:735:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BSYH:735:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYH:735:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYH:735:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BSYH:735:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYH:735:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BSYH:735:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BSYH:735:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BSYH:735:EDES NPP MS")
  field(INPB, "QUAD:BSYH:735:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BSYH:910:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "QUAD:BSYH:910:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BSYH:910:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BSYH:910:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BSYH:910:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BSYH:910:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BSYH:910:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BSYH:910:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BSYH:910:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BSYH:910:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BSYH:910:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BSYH:910:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BSYH:910:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BSYH:910:EDES.PROC PP")
    field(LNK2, "QUAD:BSYH:910:EACT.PROC PP")
    field(LNK3, "QUAD:BSYH:910:EERR.DISA PP")
    field(LNK4, "QUAD:BSYH:910:ECON.PROC PP")
    field(LNK5, "QUAD:BSYH:910:BMAGX.PROC PP")
    field(LNK6, "QUAD:BSYH:910:BMAGY.PROC PP")
    field(LNK7, "QUAD:BSYH:910:BLEM.PROC PP")
    field(LNK8, "QUAD:BSYH:910:BMOD.PROC PP")
    field(LNK9, "QUAD:BSYH:910:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BSYH:910:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BSYH:910:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BSYH:910:BMAX")
  field(DOL2, "QUAD:BSYH:910:BMAX")
  field(DOL3, "QUAD:BSYH:910:BMAX")
  field(DOL4, "QUAD:BSYH:910:BMIN")
  field(DOL5, "QUAD:BSYH:910:BMIN")
  field(DOL6, "QUAD:BSYH:910:BMIN")
  field(LNK1, "QUAD:BSYH:910:BMAGX.HOPR")
  field(LNK2, "QUAD:BSYH:910:BMAGY.HOPR")
  field(LNK3, "QUAD:BSYH:910:BLEM.HOPR")
  field(LNK4, "QUAD:BSYH:910:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BSYH:910:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BSYH:910:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BSYH:910:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BSYH:910:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BSYH:910:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BSYH:910:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BSYH:910:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYH:910:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYH:910:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BSYH:910:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYH:910:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BSYH:910:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BSYH:910:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BSYH:910:EDES NPP MS")
  field(INPB, "QUAD:BSYH:910:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BSYH:452:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "XCOR:BSYH:452:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BSYH:452:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BSYH:452:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BSYH:452:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BSYH:452:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BSYH:452:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BSYH:452:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BSYH:452:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BSYH:452:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BSYH:452:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BSYH:452:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BSYH:452:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BSYH:452:EDES.PROC PP")
    field(LNK2, "XCOR:BSYH:452:EACT.PROC PP")
    field(LNK3, "XCOR:BSYH:452:EERR.DISA PP")
    field(LNK4, "XCOR:BSYH:452:ECON.PROC PP")
    field(LNK5, "XCOR:BSYH:452:BMAGX.PROC PP")
    field(LNK6, "XCOR:BSYH:452:BMAGY.PROC PP")
    field(LNK7, "XCOR:BSYH:452:BLEM.PROC PP")
    field(LNK8, "XCOR:BSYH:452:BMOD.PROC PP")
    field(LNK9, "XCOR:BSYH:452:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BSYH:452:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BSYH:452:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BSYH:452:BMAX")
  field(DOL2, "XCOR:BSYH:452:BMAX")
  field(DOL3, "XCOR:BSYH:452:BMAX")
  field(DOL4, "XCOR:BSYH:452:BMIN")
  field(DOL5, "XCOR:BSYH:452:BMIN")
  field(DOL6, "XCOR:BSYH:452:BMIN")
  field(LNK1, "XCOR:BSYH:452:BMAGX.HOPR")
  field(LNK2, "XCOR:BSYH:452:BMAGY.HOPR")
  field(LNK3, "XCOR:BSYH:452:BLEM.HOPR")
  field(LNK4, "XCOR:BSYH:452:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BSYH:452:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BSYH:452:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BSYH:452:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BSYH:452:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BSYH:452:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BSYH:452:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BSYH:452:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BSYH:452:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BSYH:452:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BSYH:452:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BSYH:452:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BSYH:452:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BSYH:452:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BSYH:452:EDES NPP MS")
  field(INPB, "XCOR:BSYH:452:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BSYH:642:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "XCOR:BSYH:642:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BSYH:642:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BSYH:642:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BSYH:642:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BSYH:642:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BSYH:642:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BSYH:642:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BSYH:642:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BSYH:642:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BSYH:642:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BSYH:642:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BSYH:642:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BSYH:642:EDES.PROC PP")
    field(LNK2, "XCOR:BSYH:642:EACT.PROC PP")
    field(LNK3, "XCOR:BSYH:642:EERR.DISA PP")
    field(LNK4, "XCOR:BSYH:642:ECON.PROC PP")
    field(LNK5, "XCOR:BSYH:642:BMAGX.PROC PP")
    field(LNK6, "XCOR:BSYH:642:BMAGY.PROC PP")
    field(LNK7, "XCOR:BSYH:642:BLEM.PROC PP")
    field(LNK8, "XCOR:BSYH:642:BMOD.PROC PP")
    field(LNK9, "XCOR:BSYH:642:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BSYH:642:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BSYH:642:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BSYH:642:BMAX")
  field(DOL2, "XCOR:BSYH:642:BMAX")
  field(DOL3, "XCOR:BSYH:642:BMAX")
  field(DOL4, "XCOR:BSYH:642:BMIN")
  field(DOL5, "XCOR:BSYH:642:BMIN")
  field(DOL6, "XCOR:BSYH:642:BMIN")
  field(LNK1, "XCOR:BSYH:642:BMAGX.HOPR")
  field(LNK2, "XCOR:BSYH:642:BMAGY.HOPR")
  field(LNK3, "XCOR:BSYH:642:BLEM.HOPR")
  field(LNK4, "XCOR:BSYH:642:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BSYH:642:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BSYH:642:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BSYH:642:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BSYH:642:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BSYH:642:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BSYH:642:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BSYH:642:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BSYH:642:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BSYH:642:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BSYH:642:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BSYH:642:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BSYH:642:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BSYH:642:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BSYH:642:EDES NPP MS")
  field(INPB, "XCOR:BSYH:642:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BSYH:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "XCOR:BSYH:900:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BSYH:900:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BSYH:900:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BSYH:900:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BSYH:900:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BSYH:900:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BSYH:900:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BSYH:900:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BSYH:900:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BSYH:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BSYH:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BSYH:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BSYH:900:EDES.PROC PP")
    field(LNK2, "XCOR:BSYH:900:EACT.PROC PP")
    field(LNK3, "XCOR:BSYH:900:EERR.DISA PP")
    field(LNK4, "XCOR:BSYH:900:ECON.PROC PP")
    field(LNK5, "XCOR:BSYH:900:BMAGX.PROC PP")
    field(LNK6, "XCOR:BSYH:900:BMAGY.PROC PP")
    field(LNK7, "XCOR:BSYH:900:BLEM.PROC PP")
    field(LNK8, "XCOR:BSYH:900:BMOD.PROC PP")
    field(LNK9, "XCOR:BSYH:900:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BSYH:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BSYH:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BSYH:900:BMAX")
  field(DOL2, "XCOR:BSYH:900:BMAX")
  field(DOL3, "XCOR:BSYH:900:BMAX")
  field(DOL4, "XCOR:BSYH:900:BMIN")
  field(DOL5, "XCOR:BSYH:900:BMIN")
  field(DOL6, "XCOR:BSYH:900:BMIN")
  field(LNK1, "XCOR:BSYH:900:BMAGX.HOPR")
  field(LNK2, "XCOR:BSYH:900:BMAGY.HOPR")
  field(LNK3, "XCOR:BSYH:900:BLEM.HOPR")
  field(LNK4, "XCOR:BSYH:900:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BSYH:900:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BSYH:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BSYH:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BSYH:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BSYH:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BSYH:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BSYH:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BSYH:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BSYH:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BSYH:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BSYH:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BSYH:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BSYH:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BSYH:900:EDES NPP MS")
  field(INPB, "XCOR:BSYH:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BSYH:461:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "YCOR:BSYH:461:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BSYH:461:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BSYH:461:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BSYH:461:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BSYH:461:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BSYH:461:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BSYH:461:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BSYH:461:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BSYH:461:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BSYH:461:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BSYH:461:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BSYH:461:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BSYH:461:EDES.PROC PP")
    field(LNK2, "YCOR:BSYH:461:EACT.PROC PP")
    field(LNK3, "YCOR:BSYH:461:EERR.DISA PP")
    field(LNK4, "YCOR:BSYH:461:ECON.PROC PP")
    field(LNK5, "YCOR:BSYH:461:BMAGX.PROC PP")
    field(LNK6, "YCOR:BSYH:461:BMAGY.PROC PP")
    field(LNK7, "YCOR:BSYH:461:BLEM.PROC PP")
    field(LNK8, "YCOR:BSYH:461:BMOD.PROC PP")
    field(LNK9, "YCOR:BSYH:461:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BSYH:461:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BSYH:461:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BSYH:461:BMAX")
  field(DOL2, "YCOR:BSYH:461:BMAX")
  field(DOL3, "YCOR:BSYH:461:BMAX")
  field(DOL4, "YCOR:BSYH:461:BMIN")
  field(DOL5, "YCOR:BSYH:461:BMIN")
  field(DOL6, "YCOR:BSYH:461:BMIN")
  field(LNK1, "YCOR:BSYH:461:BMAGX.HOPR")
  field(LNK2, "YCOR:BSYH:461:BMAGY.HOPR")
  field(LNK3, "YCOR:BSYH:461:BLEM.HOPR")
  field(LNK4, "YCOR:BSYH:461:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BSYH:461:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BSYH:461:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BSYH:461:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BSYH:461:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BSYH:461:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BSYH:461:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BSYH:461:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BSYH:461:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BSYH:461:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BSYH:461:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BSYH:461:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BSYH:461:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BSYH:461:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BSYH:461:EDES NPP MS")
  field(INPB, "YCOR:BSYH:461:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BSYH:739:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "YCOR:BSYH:739:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BSYH:739:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BSYH:739:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BSYH:739:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BSYH:739:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BSYH:739:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BSYH:739:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BSYH:739:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BSYH:739:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BSYH:739:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BSYH:739:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BSYH:739:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BSYH:739:EDES.PROC PP")
    field(LNK2, "YCOR:BSYH:739:EACT.PROC PP")
    field(LNK3, "YCOR:BSYH:739:EERR.DISA PP")
    field(LNK4, "YCOR:BSYH:739:ECON.PROC PP")
    field(LNK5, "YCOR:BSYH:739:BMAGX.PROC PP")
    field(LNK6, "YCOR:BSYH:739:BMAGY.PROC PP")
    field(LNK7, "YCOR:BSYH:739:BLEM.PROC PP")
    field(LNK8, "YCOR:BSYH:739:BMOD.PROC PP")
    field(LNK9, "YCOR:BSYH:739:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BSYH:739:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BSYH:739:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BSYH:739:BMAX")
  field(DOL2, "YCOR:BSYH:739:BMAX")
  field(DOL3, "YCOR:BSYH:739:BMAX")
  field(DOL4, "YCOR:BSYH:739:BMIN")
  field(DOL5, "YCOR:BSYH:739:BMIN")
  field(DOL6, "YCOR:BSYH:739:BMIN")
  field(LNK1, "YCOR:BSYH:739:BMAGX.HOPR")
  field(LNK2, "YCOR:BSYH:739:BMAGY.HOPR")
  field(LNK3, "YCOR:BSYH:739:BLEM.HOPR")
  field(LNK4, "YCOR:BSYH:739:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BSYH:739:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BSYH:739:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BSYH:739:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BSYH:739:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BSYH:739:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BSYH:739:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BSYH:739:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BSYH:739:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BSYH:739:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BSYH:739:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BSYH:739:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BSYH:739:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BSYH:739:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BSYH:739:EDES NPP MS")
  field(INPB, "YCOR:BSYH:739:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BSYH:901:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "YCOR:BSYH:901:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BSYH:901:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BSYH:901:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BSYH:901:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BSYH:901:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BSYH:901:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BSYH:901:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BSYH:901:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BSYH:901:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BSYH:901:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BSYH:901:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BSYH:901:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BSYH:901:EDES.PROC PP")
    field(LNK2, "YCOR:BSYH:901:EACT.PROC PP")
    field(LNK3, "YCOR:BSYH:901:EERR.DISA PP")
    field(LNK4, "YCOR:BSYH:901:ECON.PROC PP")
    field(LNK5, "YCOR:BSYH:901:BMAGX.PROC PP")
    field(LNK6, "YCOR:BSYH:901:BMAGY.PROC PP")
    field(LNK7, "YCOR:BSYH:901:BLEM.PROC PP")
    field(LNK8, "YCOR:BSYH:901:BMOD.PROC PP")
    field(LNK9, "YCOR:BSYH:901:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BSYH:901:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BSYH:901:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BSYH:901:BMAX")
  field(DOL2, "YCOR:BSYH:901:BMAX")
  field(DOL3, "YCOR:BSYH:901:BMAX")
  field(DOL4, "YCOR:BSYH:901:BMIN")
  field(DOL5, "YCOR:BSYH:901:BMIN")
  field(DOL6, "YCOR:BSYH:901:BMIN")
  field(LNK1, "YCOR:BSYH:901:BMAGX.HOPR")
  field(LNK2, "YCOR:BSYH:901:BMAGY.HOPR")
  field(LNK3, "YCOR:BSYH:901:BLEM.HOPR")
  field(LNK4, "YCOR:BSYH:901:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BSYH:901:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BSYH:901:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BSYH:901:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BSYH:901:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BSYH:901:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BSYH:901:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BSYH:901:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BSYH:901:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BSYH:901:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BSYH:901:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BSYH:901:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BSYH:901:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BSYH:901:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BSYH:901:EDES NPP MS")
  field(INPB, "YCOR:BSYH:901:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:BSYS:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "LGPS:BSYS:1:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:BSYS:1:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:BSYS:1:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:BSYS:1:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:BSYS:1:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:BSYS:1:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:BSYS:1:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:BSYS:1:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:BSYS:1:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:BSYS:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:BSYS:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:BSYS:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:BSYS:1:EDES.PROC PP")
    field(LNK2, "LGPS:BSYS:1:EACT.PROC PP")
    field(LNK3, "LGPS:BSYS:1:EERR.DISA PP")
    field(LNK4, "LGPS:BSYS:1:ECON.PROC PP")
    field(LNK5, "LGPS:BSYS:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:BSYS:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:BSYS:1:BLEM.PROC PP")
    field(LNK8, "LGPS:BSYS:1:BMOD.PROC PP")
    field(LNK9, "LGPS:BSYS:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:BSYS:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:BSYS:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:BSYS:1:BMAX")
  field(DOL2, "LGPS:BSYS:1:BMAX")
  field(DOL3, "LGPS:BSYS:1:BMAX")
  field(DOL4, "LGPS:BSYS:1:BMIN")
  field(DOL5, "LGPS:BSYS:1:BMIN")
  field(DOL6, "LGPS:BSYS:1:BMIN")
  field(LNK1, "LGPS:BSYS:1:BMAGX.HOPR")
  field(LNK2, "LGPS:BSYS:1:BMAGY.HOPR")
  field(LNK3, "LGPS:BSYS:1:BLEM.HOPR")
  field(LNK4, "LGPS:BSYS:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:BSYS:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:BSYS:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:BSYS:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:BSYS:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:BSYS:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:BSYS:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:BSYS:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BSYS:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BSYS:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BSYS:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BSYS:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BSYS:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:BSYS:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:BSYS:1:EDES NPP MS")
  field(INPB, "LGPS:BSYS:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BSYS:820:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "QUAD:BSYS:820:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BSYS:820:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BSYS:820:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BSYS:820:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BSYS:820:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BSYS:820:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BSYS:820:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BSYS:820:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BSYS:820:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BSYS:820:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BSYS:820:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BSYS:820:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BSYS:820:EDES.PROC PP")
    field(LNK2, "QUAD:BSYS:820:EACT.PROC PP")
    field(LNK3, "QUAD:BSYS:820:EERR.DISA PP")
    field(LNK4, "QUAD:BSYS:820:ECON.PROC PP")
    field(LNK5, "QUAD:BSYS:820:BMAGX.PROC PP")
    field(LNK6, "QUAD:BSYS:820:BMAGY.PROC PP")
    field(LNK7, "QUAD:BSYS:820:BLEM.PROC PP")
    field(LNK8, "QUAD:BSYS:820:BMOD.PROC PP")
    field(LNK9, "QUAD:BSYS:820:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BSYS:820:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BSYS:820:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BSYS:820:BMAX")
  field(DOL2, "QUAD:BSYS:820:BMAX")
  field(DOL3, "QUAD:BSYS:820:BMAX")
  field(DOL4, "QUAD:BSYS:820:BMIN")
  field(DOL5, "QUAD:BSYS:820:BMIN")
  field(DOL6, "QUAD:BSYS:820:BMIN")
  field(LNK1, "QUAD:BSYS:820:BMAGX.HOPR")
  field(LNK2, "QUAD:BSYS:820:BMAGY.HOPR")
  field(LNK3, "QUAD:BSYS:820:BLEM.HOPR")
  field(LNK4, "QUAD:BSYS:820:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BSYS:820:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BSYS:820:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BSYS:820:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BSYS:820:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BSYS:820:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BSYS:820:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BSYS:820:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYS:820:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYS:820:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BSYS:820:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYS:820:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BSYS:820:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BSYS:820:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BSYS:820:EDES NPP MS")
  field(INPB, "QUAD:BSYS:820:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BSYS:865:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "QUAD:BSYS:865:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BSYS:865:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BSYS:865:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BSYS:865:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BSYS:865:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BSYS:865:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BSYS:865:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BSYS:865:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BSYS:865:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BSYS:865:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BSYS:865:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BSYS:865:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BSYS:865:EDES.PROC PP")
    field(LNK2, "QUAD:BSYS:865:EACT.PROC PP")
    field(LNK3, "QUAD:BSYS:865:EERR.DISA PP")
    field(LNK4, "QUAD:BSYS:865:ECON.PROC PP")
    field(LNK5, "QUAD:BSYS:865:BMAGX.PROC PP")
    field(LNK6, "QUAD:BSYS:865:BMAGY.PROC PP")
    field(LNK7, "QUAD:BSYS:865:BLEM.PROC PP")
    field(LNK8, "QUAD:BSYS:865:BMOD.PROC PP")
    field(LNK9, "QUAD:BSYS:865:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BSYS:865:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BSYS:865:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BSYS:865:BMAX")
  field(DOL2, "QUAD:BSYS:865:BMAX")
  field(DOL3, "QUAD:BSYS:865:BMAX")
  field(DOL4, "QUAD:BSYS:865:BMIN")
  field(DOL5, "QUAD:BSYS:865:BMIN")
  field(DOL6, "QUAD:BSYS:865:BMIN")
  field(LNK1, "QUAD:BSYS:865:BMAGX.HOPR")
  field(LNK2, "QUAD:BSYS:865:BMAGY.HOPR")
  field(LNK3, "QUAD:BSYS:865:BLEM.HOPR")
  field(LNK4, "QUAD:BSYS:865:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BSYS:865:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BSYS:865:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BSYS:865:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BSYS:865:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BSYS:865:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BSYS:865:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BSYS:865:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYS:865:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYS:865:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BSYS:865:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BSYS:865:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BSYS:865:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BSYS:865:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BSYS:865:EDES NPP MS")
  field(INPB, "QUAD:BSYS:865:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BSYS:822:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "XCOR:BSYS:822:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BSYS:822:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BSYS:822:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BSYS:822:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BSYS:822:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BSYS:822:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BSYS:822:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BSYS:822:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BSYS:822:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BSYS:822:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BSYS:822:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BSYS:822:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BSYS:822:EDES.PROC PP")
    field(LNK2, "XCOR:BSYS:822:EACT.PROC PP")
    field(LNK3, "XCOR:BSYS:822:EERR.DISA PP")
    field(LNK4, "XCOR:BSYS:822:ECON.PROC PP")
    field(LNK5, "XCOR:BSYS:822:BMAGX.PROC PP")
    field(LNK6, "XCOR:BSYS:822:BMAGY.PROC PP")
    field(LNK7, "XCOR:BSYS:822:BLEM.PROC PP")
    field(LNK8, "XCOR:BSYS:822:BMOD.PROC PP")
    field(LNK9, "XCOR:BSYS:822:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BSYS:822:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BSYS:822:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BSYS:822:BMAX")
  field(DOL2, "XCOR:BSYS:822:BMAX")
  field(DOL3, "XCOR:BSYS:822:BMAX")
  field(DOL4, "XCOR:BSYS:822:BMIN")
  field(DOL5, "XCOR:BSYS:822:BMIN")
  field(DOL6, "XCOR:BSYS:822:BMIN")
  field(LNK1, "XCOR:BSYS:822:BMAGX.HOPR")
  field(LNK2, "XCOR:BSYS:822:BMAGY.HOPR")
  field(LNK3, "XCOR:BSYS:822:BLEM.HOPR")
  field(LNK4, "XCOR:BSYS:822:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BSYS:822:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BSYS:822:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BSYS:822:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BSYS:822:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BSYS:822:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BSYS:822:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BSYS:822:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BSYS:822:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BSYS:822:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BSYS:822:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BSYS:822:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BSYS:822:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BSYS:822:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BSYS:822:EDES NPP MS")
  field(INPB, "XCOR:BSYS:822:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BSYS:872:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "XCOR:BSYS:872:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BSYS:872:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BSYS:872:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BSYS:872:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BSYS:872:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BSYS:872:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BSYS:872:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BSYS:872:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BSYS:872:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BSYS:872:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BSYS:872:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BSYS:872:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BSYS:872:EDES.PROC PP")
    field(LNK2, "XCOR:BSYS:872:EACT.PROC PP")
    field(LNK3, "XCOR:BSYS:872:EERR.DISA PP")
    field(LNK4, "XCOR:BSYS:872:ECON.PROC PP")
    field(LNK5, "XCOR:BSYS:872:BMAGX.PROC PP")
    field(LNK6, "XCOR:BSYS:872:BMAGY.PROC PP")
    field(LNK7, "XCOR:BSYS:872:BLEM.PROC PP")
    field(LNK8, "XCOR:BSYS:872:BMOD.PROC PP")
    field(LNK9, "XCOR:BSYS:872:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BSYS:872:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BSYS:872:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BSYS:872:BMAX")
  field(DOL2, "XCOR:BSYS:872:BMAX")
  field(DOL3, "XCOR:BSYS:872:BMAX")
  field(DOL4, "XCOR:BSYS:872:BMIN")
  field(DOL5, "XCOR:BSYS:872:BMIN")
  field(DOL6, "XCOR:BSYS:872:BMIN")
  field(LNK1, "XCOR:BSYS:872:BMAGX.HOPR")
  field(LNK2, "XCOR:BSYS:872:BMAGY.HOPR")
  field(LNK3, "XCOR:BSYS:872:BLEM.HOPR")
  field(LNK4, "XCOR:BSYS:872:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BSYS:872:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BSYS:872:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BSYS:872:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BSYS:872:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BSYS:872:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BSYS:872:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BSYS:872:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BSYS:872:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BSYS:872:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BSYS:872:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BSYS:872:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BSYS:872:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BSYS:872:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BSYS:872:EDES NPP MS")
  field(INPB, "XCOR:BSYS:872:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BSYS:823:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "YCOR:BSYS:823:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BSYS:823:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BSYS:823:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BSYS:823:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BSYS:823:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BSYS:823:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BSYS:823:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BSYS:823:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BSYS:823:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BSYS:823:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BSYS:823:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BSYS:823:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BSYS:823:EDES.PROC PP")
    field(LNK2, "YCOR:BSYS:823:EACT.PROC PP")
    field(LNK3, "YCOR:BSYS:823:EERR.DISA PP")
    field(LNK4, "YCOR:BSYS:823:ECON.PROC PP")
    field(LNK5, "YCOR:BSYS:823:BMAGX.PROC PP")
    field(LNK6, "YCOR:BSYS:823:BMAGY.PROC PP")
    field(LNK7, "YCOR:BSYS:823:BLEM.PROC PP")
    field(LNK8, "YCOR:BSYS:823:BMOD.PROC PP")
    field(LNK9, "YCOR:BSYS:823:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BSYS:823:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BSYS:823:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BSYS:823:BMAX")
  field(DOL2, "YCOR:BSYS:823:BMAX")
  field(DOL3, "YCOR:BSYS:823:BMAX")
  field(DOL4, "YCOR:BSYS:823:BMIN")
  field(DOL5, "YCOR:BSYS:823:BMIN")
  field(DOL6, "YCOR:BSYS:823:BMIN")
  field(LNK1, "YCOR:BSYS:823:BMAGX.HOPR")
  field(LNK2, "YCOR:BSYS:823:BMAGY.HOPR")
  field(LNK3, "YCOR:BSYS:823:BLEM.HOPR")
  field(LNK4, "YCOR:BSYS:823:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BSYS:823:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BSYS:823:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BSYS:823:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BSYS:823:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BSYS:823:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BSYS:823:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BSYS:823:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BSYS:823:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BSYS:823:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BSYS:823:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BSYS:823:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BSYS:823:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BSYS:823:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BSYS:823:EDES NPP MS")
  field(INPB, "YCOR:BSYS:823:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BSYS:873:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CTRL.RVAL")
  field(LNK1, "YCOR:BSYS:873:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BSYS:873:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BSYS:873:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BSYS:873:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BSYS:873:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BSYS:873:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BSYS:873:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BSYS:873:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BSYS:873:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BSYS:873:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BSYS:873:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BSYS:873:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BSYS:873:EDES.PROC PP")
    field(LNK2, "YCOR:BSYS:873:EACT.PROC PP")
    field(LNK3, "YCOR:BSYS:873:EERR.DISA PP")
    field(LNK4, "YCOR:BSYS:873:ECON.PROC PP")
    field(LNK5, "YCOR:BSYS:873:BMAGX.PROC PP")
    field(LNK6, "YCOR:BSYS:873:BMAGY.PROC PP")
    field(LNK7, "YCOR:BSYS:873:BLEM.PROC PP")
    field(LNK8, "YCOR:BSYS:873:BMOD.PROC PP")
    field(LNK9, "YCOR:BSYS:873:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BSYS:873:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BSYS:873:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BSYS:873:BMAX")
  field(DOL2, "YCOR:BSYS:873:BMAX")
  field(DOL3, "YCOR:BSYS:873:BMAX")
  field(DOL4, "YCOR:BSYS:873:BMIN")
  field(DOL5, "YCOR:BSYS:873:BMIN")
  field(DOL6, "YCOR:BSYS:873:BMIN")
  field(LNK1, "YCOR:BSYS:873:BMAGX.HOPR")
  field(LNK2, "YCOR:BSYS:873:BMAGY.HOPR")
  field(LNK3, "YCOR:BSYS:873:BLEM.HOPR")
  field(LNK4, "YCOR:BSYS:873:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BSYS:873:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BSYS:873:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BSYS:873:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BSYS:873:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BSYS:873:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BSYS:873:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BSYS:873:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BSYS:873:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BSYS:873:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BSYS:873:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BSYS:873:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BSYS:873:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BSYS:873:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BSYS:873:EDES NPP MS")
  field(INPB, "YCOR:BSYS:873:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:SLTH:145:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTH:1:CTRL.RVAL")
  field(LNK1, "BEND:SLTH:145:FUNC CA PP")
  field(DOL2, "MGNT:SLTH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:SLTH:145:FUNC CA PP")
  field(DOL3, "MGNT:SLTH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:SLTH:145:FUNC CA PP")
  field(DOL4, "MGNT:SLTH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:SLTH:145:FUNC CA PP")
  field(DOL5, "MGNT:SLTH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:SLTH:145:FUNC CA PP")
  field(DOL6, "MGNT:SLTH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:SLTH:145:FUNC CA PP")
  field(DOL7, "MGNT:SLTH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:SLTH:145:FUNC CA PP")
  field(DOL8, "MGNT:SLTH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:SLTH:145:FUNC CA PP")
  field(DOL9, "MGNT:SLTH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:SLTH:145:FUNC CA PP")
  field(DOLA, "MGNT:SLTH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:SLTH:145:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:SLTH:145:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:SLTH:145:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:SLTH:145:EDES.PROC PP")
    field(LNK2, "BEND:SLTH:145:EACT.PROC PP")
    field(LNK3, "BEND:SLTH:145:EERR.DISA PP")
    field(LNK4, "BEND:SLTH:145:ECON.PROC PP")
    field(LNK5, "BEND:SLTH:145:BMAGX.PROC PP")
    field(LNK6, "BEND:SLTH:145:BMAGY.PROC PP")
    field(LNK7, "BEND:SLTH:145:BLEM.PROC PP")
    field(LNK8, "BEND:SLTH:145:BMOD.PROC PP")
    field(LNK9, "BEND:SLTH:145:EDESSAVE.PROC PP")
    field(LNKA, "BEND:SLTH:145:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:SLTH:145:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:SLTH:145:BMAX")
  field(DOL2, "BEND:SLTH:145:BMAX")
  field(DOL3, "BEND:SLTH:145:BMAX")
  field(DOL4, "BEND:SLTH:145:BMIN")
  field(DOL5, "BEND:SLTH:145:BMIN")
  field(DOL6, "BEND:SLTH:145:BMIN")
  field(LNK1, "BEND:SLTH:145:BMAGX.HOPR")
  field(LNK2, "BEND:SLTH:145:BMAGY.HOPR")
  field(LNK3, "BEND:SLTH:145:BLEM.HOPR")
  field(LNK4, "BEND:SLTH:145:BMAGX.LOPR PP")
  field(LNK5, "BEND:SLTH:145:BMAGY.LOPR PP")
  field(LNK6, "BEND:SLTH:145:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:SLTH:145:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:SLTH:145:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:SLTH:145:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:SLTH:145:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:SLTH:145:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SLTH:145:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SLTH:145:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SLTH:145:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SLTH:145:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SLTH:145:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:SLTH:145:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:SLTH:145:EDES NPP MS")
  field(INPB, "BEND:SLTH:145:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:SLTH:435:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTH:1:CTRL.RVAL")
  field(LNK1, "BEND:SLTH:435:FUNC CA PP")
  field(DOL2, "MGNT:SLTH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:SLTH:435:FUNC CA PP")
  field(DOL3, "MGNT:SLTH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:SLTH:435:FUNC CA PP")
  field(DOL4, "MGNT:SLTH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:SLTH:435:FUNC CA PP")
  field(DOL5, "MGNT:SLTH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:SLTH:435:FUNC CA PP")
  field(DOL6, "MGNT:SLTH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:SLTH:435:FUNC CA PP")
  field(DOL7, "MGNT:SLTH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:SLTH:435:FUNC CA PP")
  field(DOL8, "MGNT:SLTH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:SLTH:435:FUNC CA PP")
  field(DOL9, "MGNT:SLTH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:SLTH:435:FUNC CA PP")
  field(DOLA, "MGNT:SLTH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:SLTH:435:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:SLTH:435:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:SLTH:435:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:SLTH:435:EDES.PROC PP")
    field(LNK2, "BEND:SLTH:435:EACT.PROC PP")
    field(LNK3, "BEND:SLTH:435:EERR.DISA PP")
    field(LNK4, "BEND:SLTH:435:ECON.PROC PP")
    field(LNK5, "BEND:SLTH:435:BMAGX.PROC PP")
    field(LNK6, "BEND:SLTH:435:BMAGY.PROC PP")
    field(LNK7, "BEND:SLTH:435:BLEM.PROC PP")
    field(LNK8, "BEND:SLTH:435:BMOD.PROC PP")
    field(LNK9, "BEND:SLTH:435:EDESSAVE.PROC PP")
    field(LNKA, "BEND:SLTH:435:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:SLTH:435:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:SLTH:435:BMAX")
  field(DOL2, "BEND:SLTH:435:BMAX")
  field(DOL3, "BEND:SLTH:435:BMAX")
  field(DOL4, "BEND:SLTH:435:BMIN")
  field(DOL5, "BEND:SLTH:435:BMIN")
  field(DOL6, "BEND:SLTH:435:BMIN")
  field(LNK1, "BEND:SLTH:435:BMAGX.HOPR")
  field(LNK2, "BEND:SLTH:435:BMAGY.HOPR")
  field(LNK3, "BEND:SLTH:435:BLEM.HOPR")
  field(LNK4, "BEND:SLTH:435:BMAGX.LOPR PP")
  field(LNK5, "BEND:SLTH:435:BMAGY.LOPR PP")
  field(LNK6, "BEND:SLTH:435:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:SLTH:435:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:SLTH:435:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:SLTH:435:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:SLTH:435:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:SLTH:435:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SLTH:435:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SLTH:435:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SLTH:435:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SLTH:435:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SLTH:435:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:SLTH:435:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:SLTH:435:EDES NPP MS")
  field(INPB, "BEND:SLTH:435:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:SLTH:435:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTH:1:CTRL.RVAL")
  field(LNK1, "BTRM:SLTH:435:FUNC CA PP")
  field(DOL2, "MGNT:SLTH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:SLTH:435:FUNC CA PP")
  field(DOL3, "MGNT:SLTH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:SLTH:435:FUNC CA PP")
  field(DOL4, "MGNT:SLTH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:SLTH:435:FUNC CA PP")
  field(DOL5, "MGNT:SLTH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:SLTH:435:FUNC CA PP")
  field(DOL6, "MGNT:SLTH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:SLTH:435:FUNC CA PP")
  field(DOL7, "MGNT:SLTH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:SLTH:435:FUNC CA PP")
  field(DOL8, "MGNT:SLTH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:SLTH:435:FUNC CA PP")
  field(DOL9, "MGNT:SLTH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:SLTH:435:FUNC CA PP")
  field(DOLA, "MGNT:SLTH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:SLTH:435:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:SLTH:435:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:SLTH:435:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:SLTH:435:EDES.PROC PP")
    field(LNK2, "BTRM:SLTH:435:EACT.PROC PP")
    field(LNK3, "BTRM:SLTH:435:EERR.DISA PP")
    field(LNK4, "BTRM:SLTH:435:ECON.PROC PP")
    field(LNK5, "BTRM:SLTH:435:BMAGX.PROC PP")
    field(LNK6, "BTRM:SLTH:435:BMAGY.PROC PP")
    field(LNK7, "BTRM:SLTH:435:BLEM.PROC PP")
    field(LNK8, "BTRM:SLTH:435:BMOD.PROC PP")
    field(LNK9, "BTRM:SLTH:435:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:SLTH:435:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:SLTH:435:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:SLTH:435:BMAX")
  field(DOL2, "BTRM:SLTH:435:BMAX")
  field(DOL3, "BTRM:SLTH:435:BMAX")
  field(DOL4, "BTRM:SLTH:435:BMIN")
  field(DOL5, "BTRM:SLTH:435:BMIN")
  field(DOL6, "BTRM:SLTH:435:BMIN")
  field(LNK1, "BTRM:SLTH:435:BMAGX.HOPR")
  field(LNK2, "BTRM:SLTH:435:BMAGY.HOPR")
  field(LNK3, "BTRM:SLTH:435:BLEM.HOPR")
  field(LNK4, "BTRM:SLTH:435:BMAGX.LOPR PP")
  field(LNK5, "BTRM:SLTH:435:BMAGY.LOPR PP")
  field(LNK6, "BTRM:SLTH:435:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:SLTH:435:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:SLTH:435:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:SLTH:435:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:SLTH:435:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:SLTH:435:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SLTH:435:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SLTH:435:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:SLTH:435:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SLTH:435:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:SLTH:435:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:SLTH:435:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:SLTH:435:EDES NPP MS")
  field(INPB, "BTRM:SLTH:435:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SLTH:200:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTH:1:CTRL.RVAL")
  field(LNK1, "QUAD:SLTH:200:FUNC CA PP")
  field(DOL2, "MGNT:SLTH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SLTH:200:FUNC CA PP")
  field(DOL3, "MGNT:SLTH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SLTH:200:FUNC CA PP")
  field(DOL4, "MGNT:SLTH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SLTH:200:FUNC CA PP")
  field(DOL5, "MGNT:SLTH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SLTH:200:FUNC CA PP")
  field(DOL6, "MGNT:SLTH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SLTH:200:FUNC CA PP")
  field(DOL7, "MGNT:SLTH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SLTH:200:FUNC CA PP")
  field(DOL8, "MGNT:SLTH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SLTH:200:FUNC CA PP")
  field(DOL9, "MGNT:SLTH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SLTH:200:FUNC CA PP")
  field(DOLA, "MGNT:SLTH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SLTH:200:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SLTH:200:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SLTH:200:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SLTH:200:EDES.PROC PP")
    field(LNK2, "QUAD:SLTH:200:EACT.PROC PP")
    field(LNK3, "QUAD:SLTH:200:EERR.DISA PP")
    field(LNK4, "QUAD:SLTH:200:ECON.PROC PP")
    field(LNK5, "QUAD:SLTH:200:BMAGX.PROC PP")
    field(LNK6, "QUAD:SLTH:200:BMAGY.PROC PP")
    field(LNK7, "QUAD:SLTH:200:BLEM.PROC PP")
    field(LNK8, "QUAD:SLTH:200:BMOD.PROC PP")
    field(LNK9, "QUAD:SLTH:200:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SLTH:200:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SLTH:200:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SLTH:200:BMAX")
  field(DOL2, "QUAD:SLTH:200:BMAX")
  field(DOL3, "QUAD:SLTH:200:BMAX")
  field(DOL4, "QUAD:SLTH:200:BMIN")
  field(DOL5, "QUAD:SLTH:200:BMIN")
  field(DOL6, "QUAD:SLTH:200:BMIN")
  field(LNK1, "QUAD:SLTH:200:BMAGX.HOPR")
  field(LNK2, "QUAD:SLTH:200:BMAGY.HOPR")
  field(LNK3, "QUAD:SLTH:200:BLEM.HOPR")
  field(LNK4, "QUAD:SLTH:200:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SLTH:200:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SLTH:200:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SLTH:200:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SLTH:200:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SLTH:200:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SLTH:200:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SLTH:200:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTH:200:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTH:200:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SLTH:200:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTH:200:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SLTH:200:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SLTH:200:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SLTH:200:EDES NPP MS")
  field(INPB, "QUAD:SLTH:200:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SLTH:218:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTH:1:CTRL.RVAL")
  field(LNK1, "XCOR:SLTH:218:FUNC CA PP")
  field(DOL2, "MGNT:SLTH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SLTH:218:FUNC CA PP")
  field(DOL3, "MGNT:SLTH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SLTH:218:FUNC CA PP")
  field(DOL4, "MGNT:SLTH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SLTH:218:FUNC CA PP")
  field(DOL5, "MGNT:SLTH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SLTH:218:FUNC CA PP")
  field(DOL6, "MGNT:SLTH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SLTH:218:FUNC CA PP")
  field(DOL7, "MGNT:SLTH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SLTH:218:FUNC CA PP")
  field(DOL8, "MGNT:SLTH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SLTH:218:FUNC CA PP")
  field(DOL9, "MGNT:SLTH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SLTH:218:FUNC CA PP")
  field(DOLA, "MGNT:SLTH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SLTH:218:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SLTH:218:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SLTH:218:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SLTH:218:EDES.PROC PP")
    field(LNK2, "XCOR:SLTH:218:EACT.PROC PP")
    field(LNK3, "XCOR:SLTH:218:EERR.DISA PP")
    field(LNK4, "XCOR:SLTH:218:ECON.PROC PP")
    field(LNK5, "XCOR:SLTH:218:BMAGX.PROC PP")
    field(LNK6, "XCOR:SLTH:218:BMAGY.PROC PP")
    field(LNK7, "XCOR:SLTH:218:BLEM.PROC PP")
    field(LNK8, "XCOR:SLTH:218:BMOD.PROC PP")
    field(LNK9, "XCOR:SLTH:218:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SLTH:218:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SLTH:218:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SLTH:218:BMAX")
  field(DOL2, "XCOR:SLTH:218:BMAX")
  field(DOL3, "XCOR:SLTH:218:BMAX")
  field(DOL4, "XCOR:SLTH:218:BMIN")
  field(DOL5, "XCOR:SLTH:218:BMIN")
  field(DOL6, "XCOR:SLTH:218:BMIN")
  field(LNK1, "XCOR:SLTH:218:BMAGX.HOPR")
  field(LNK2, "XCOR:SLTH:218:BMAGY.HOPR")
  field(LNK3, "XCOR:SLTH:218:BLEM.HOPR")
  field(LNK4, "XCOR:SLTH:218:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SLTH:218:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SLTH:218:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SLTH:218:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SLTH:218:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SLTH:218:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SLTH:218:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SLTH:218:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SLTH:218:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SLTH:218:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SLTH:218:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SLTH:218:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SLTH:218:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SLTH:218:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SLTH:218:EDES NPP MS")
  field(INPB, "XCOR:SLTH:218:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SLTH:201:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTH:1:CTRL.RVAL")
  field(LNK1, "YCOR:SLTH:201:FUNC CA PP")
  field(DOL2, "MGNT:SLTH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SLTH:201:FUNC CA PP")
  field(DOL3, "MGNT:SLTH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SLTH:201:FUNC CA PP")
  field(DOL4, "MGNT:SLTH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SLTH:201:FUNC CA PP")
  field(DOL5, "MGNT:SLTH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SLTH:201:FUNC CA PP")
  field(DOL6, "MGNT:SLTH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SLTH:201:FUNC CA PP")
  field(DOL7, "MGNT:SLTH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SLTH:201:FUNC CA PP")
  field(DOL8, "MGNT:SLTH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SLTH:201:FUNC CA PP")
  field(DOL9, "MGNT:SLTH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SLTH:201:FUNC CA PP")
  field(DOLA, "MGNT:SLTH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SLTH:201:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SLTH:201:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SLTH:201:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SLTH:201:EDES.PROC PP")
    field(LNK2, "YCOR:SLTH:201:EACT.PROC PP")
    field(LNK3, "YCOR:SLTH:201:EERR.DISA PP")
    field(LNK4, "YCOR:SLTH:201:ECON.PROC PP")
    field(LNK5, "YCOR:SLTH:201:BMAGX.PROC PP")
    field(LNK6, "YCOR:SLTH:201:BMAGY.PROC PP")
    field(LNK7, "YCOR:SLTH:201:BLEM.PROC PP")
    field(LNK8, "YCOR:SLTH:201:BMOD.PROC PP")
    field(LNK9, "YCOR:SLTH:201:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SLTH:201:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SLTH:201:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SLTH:201:BMAX")
  field(DOL2, "YCOR:SLTH:201:BMAX")
  field(DOL3, "YCOR:SLTH:201:BMAX")
  field(DOL4, "YCOR:SLTH:201:BMIN")
  field(DOL5, "YCOR:SLTH:201:BMIN")
  field(DOL6, "YCOR:SLTH:201:BMIN")
  field(LNK1, "YCOR:SLTH:201:BMAGX.HOPR")
  field(LNK2, "YCOR:SLTH:201:BMAGY.HOPR")
  field(LNK3, "YCOR:SLTH:201:BLEM.HOPR")
  field(LNK4, "YCOR:SLTH:201:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SLTH:201:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SLTH:201:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SLTH:201:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SLTH:201:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SLTH:201:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SLTH:201:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SLTH:201:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SLTH:201:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SLTH:201:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SLTH:201:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SLTH:201:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SLTH:201:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SLTH:201:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SLTH:201:EDES NPP MS")
  field(INPB, "YCOR:SLTH:201:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:SPH:170:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTH:1:CTRL.RVAL")
  field(LNK1, "BTRM:SPH:170:FUNC CA PP")
  field(DOL2, "MGNT:SLTH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:SPH:170:FUNC CA PP")
  field(DOL3, "MGNT:SLTH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:SPH:170:FUNC CA PP")
  field(DOL4, "MGNT:SLTH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:SPH:170:FUNC CA PP")
  field(DOL5, "MGNT:SLTH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:SPH:170:FUNC CA PP")
  field(DOL6, "MGNT:SLTH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:SPH:170:FUNC CA PP")
  field(DOL7, "MGNT:SLTH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:SPH:170:FUNC CA PP")
  field(DOL8, "MGNT:SLTH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:SPH:170:FUNC CA PP")
  field(DOL9, "MGNT:SLTH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:SPH:170:FUNC CA PP")
  field(DOLA, "MGNT:SLTH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:SPH:170:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:SPH:170:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:SPH:170:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:SPH:170:EDES.PROC PP")
    field(LNK2, "BTRM:SPH:170:EACT.PROC PP")
    field(LNK3, "BTRM:SPH:170:EERR.DISA PP")
    field(LNK4, "BTRM:SPH:170:ECON.PROC PP")
    field(LNK5, "BTRM:SPH:170:BMAGX.PROC PP")
    field(LNK6, "BTRM:SPH:170:BMAGY.PROC PP")
    field(LNK7, "BTRM:SPH:170:BLEM.PROC PP")
    field(LNK8, "BTRM:SPH:170:BMOD.PROC PP")
    field(LNK9, "BTRM:SPH:170:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:SPH:170:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:SPH:170:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:SPH:170:BMAX")
  field(DOL2, "BTRM:SPH:170:BMAX")
  field(DOL3, "BTRM:SPH:170:BMAX")
  field(DOL4, "BTRM:SPH:170:BMIN")
  field(DOL5, "BTRM:SPH:170:BMIN")
  field(DOL6, "BTRM:SPH:170:BMIN")
  field(LNK1, "BTRM:SPH:170:BMAGX.HOPR")
  field(LNK2, "BTRM:SPH:170:BMAGY.HOPR")
  field(LNK3, "BTRM:SPH:170:BLEM.HOPR")
  field(LNK4, "BTRM:SPH:170:BMAGX.LOPR PP")
  field(LNK5, "BTRM:SPH:170:BMAGY.LOPR PP")
  field(LNK6, "BTRM:SPH:170:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:SPH:170:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:SPH:170:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:SPH:170:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:SPH:170:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:SPH:170:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPH:170:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPH:170:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:SPH:170:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPH:170:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:SPH:170:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:SPH:170:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:SPH:170:EDES NPP MS")
  field(INPB, "BTRM:SPH:170:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:SPH:370:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTH:1:CTRL.RVAL")
  field(LNK1, "BTRM:SPH:370:FUNC CA PP")
  field(DOL2, "MGNT:SLTH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:SPH:370:FUNC CA PP")
  field(DOL3, "MGNT:SLTH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:SPH:370:FUNC CA PP")
  field(DOL4, "MGNT:SLTH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:SPH:370:FUNC CA PP")
  field(DOL5, "MGNT:SLTH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:SPH:370:FUNC CA PP")
  field(DOL6, "MGNT:SLTH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:SPH:370:FUNC CA PP")
  field(DOL7, "MGNT:SLTH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:SPH:370:FUNC CA PP")
  field(DOL8, "MGNT:SLTH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:SPH:370:FUNC CA PP")
  field(DOL9, "MGNT:SLTH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:SPH:370:FUNC CA PP")
  field(DOLA, "MGNT:SLTH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:SPH:370:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:SPH:370:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:SPH:370:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:SPH:370:EDES.PROC PP")
    field(LNK2, "BTRM:SPH:370:EACT.PROC PP")
    field(LNK3, "BTRM:SPH:370:EERR.DISA PP")
    field(LNK4, "BTRM:SPH:370:ECON.PROC PP")
    field(LNK5, "BTRM:SPH:370:BMAGX.PROC PP")
    field(LNK6, "BTRM:SPH:370:BMAGY.PROC PP")
    field(LNK7, "BTRM:SPH:370:BLEM.PROC PP")
    field(LNK8, "BTRM:SPH:370:BMOD.PROC PP")
    field(LNK9, "BTRM:SPH:370:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:SPH:370:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:SPH:370:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:SPH:370:BMAX")
  field(DOL2, "BTRM:SPH:370:BMAX")
  field(DOL3, "BTRM:SPH:370:BMAX")
  field(DOL4, "BTRM:SPH:370:BMIN")
  field(DOL5, "BTRM:SPH:370:BMIN")
  field(DOL6, "BTRM:SPH:370:BMIN")
  field(LNK1, "BTRM:SPH:370:BMAGX.HOPR")
  field(LNK2, "BTRM:SPH:370:BMAGY.HOPR")
  field(LNK3, "BTRM:SPH:370:BLEM.HOPR")
  field(LNK4, "BTRM:SPH:370:BMAGX.LOPR PP")
  field(LNK5, "BTRM:SPH:370:BMAGY.LOPR PP")
  field(LNK6, "BTRM:SPH:370:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:SPH:370:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:SPH:370:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:SPH:370:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:SPH:370:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:SPH:370:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPH:370:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPH:370:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:SPH:370:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPH:370:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:SPH:370:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:SPH:370:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:SPH:370:EDES NPP MS")
  field(INPB, "BTRM:SPH:370:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:SLTS:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTS:1:CTRL.RVAL")
  field(LNK1, "LGPS:SLTS:1:FUNC CA PP")
  field(DOL2, "MGNT:SLTS:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:SLTS:1:FUNC CA PP")
  field(DOL3, "MGNT:SLTS:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:SLTS:1:FUNC CA PP")
  field(DOL4, "MGNT:SLTS:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:SLTS:1:FUNC CA PP")
  field(DOL5, "MGNT:SLTS:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:SLTS:1:FUNC CA PP")
  field(DOL6, "MGNT:SLTS:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:SLTS:1:FUNC CA PP")
  field(DOL7, "MGNT:SLTS:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:SLTS:1:FUNC CA PP")
  field(DOL8, "MGNT:SLTS:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:SLTS:1:FUNC CA PP")
  field(DOL9, "MGNT:SLTS:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:SLTS:1:FUNC CA PP")
  field(DOLA, "MGNT:SLTS:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:SLTS:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:SLTS:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:SLTS:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:SLTS:1:EDES.PROC PP")
    field(LNK2, "LGPS:SLTS:1:EACT.PROC PP")
    field(LNK3, "LGPS:SLTS:1:EERR.DISA PP")
    field(LNK4, "LGPS:SLTS:1:ECON.PROC PP")
    field(LNK5, "LGPS:SLTS:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:SLTS:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:SLTS:1:BLEM.PROC PP")
    field(LNK8, "LGPS:SLTS:1:BMOD.PROC PP")
    field(LNK9, "LGPS:SLTS:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:SLTS:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:SLTS:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:SLTS:1:BMAX")
  field(DOL2, "LGPS:SLTS:1:BMAX")
  field(DOL3, "LGPS:SLTS:1:BMAX")
  field(DOL4, "LGPS:SLTS:1:BMIN")
  field(DOL5, "LGPS:SLTS:1:BMIN")
  field(DOL6, "LGPS:SLTS:1:BMIN")
  field(LNK1, "LGPS:SLTS:1:BMAGX.HOPR")
  field(LNK2, "LGPS:SLTS:1:BMAGY.HOPR")
  field(LNK3, "LGPS:SLTS:1:BLEM.HOPR")
  field(LNK4, "LGPS:SLTS:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:SLTS:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:SLTS:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:SLTS:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:SLTS:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:SLTS:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:SLTS:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:SLTS:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:SLTS:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:SLTS:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:SLTS:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:SLTS:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:SLTS:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:SLTS:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:SLTS:1:EDES NPP MS")
  field(INPB, "LGPS:SLTS:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SLTS:150:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTS:1:CTRL.RVAL")
  field(LNK1, "QUAD:SLTS:150:FUNC CA PP")
  field(DOL2, "MGNT:SLTS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SLTS:150:FUNC CA PP")
  field(DOL3, "MGNT:SLTS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SLTS:150:FUNC CA PP")
  field(DOL4, "MGNT:SLTS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SLTS:150:FUNC CA PP")
  field(DOL5, "MGNT:SLTS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SLTS:150:FUNC CA PP")
  field(DOL6, "MGNT:SLTS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SLTS:150:FUNC CA PP")
  field(DOL7, "MGNT:SLTS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SLTS:150:FUNC CA PP")
  field(DOL8, "MGNT:SLTS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SLTS:150:FUNC CA PP")
  field(DOL9, "MGNT:SLTS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SLTS:150:FUNC CA PP")
  field(DOLA, "MGNT:SLTS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SLTS:150:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SLTS:150:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SLTS:150:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SLTS:150:EDES.PROC PP")
    field(LNK2, "QUAD:SLTS:150:EACT.PROC PP")
    field(LNK3, "QUAD:SLTS:150:EERR.DISA PP")
    field(LNK4, "QUAD:SLTS:150:ECON.PROC PP")
    field(LNK5, "QUAD:SLTS:150:BMAGX.PROC PP")
    field(LNK6, "QUAD:SLTS:150:BMAGY.PROC PP")
    field(LNK7, "QUAD:SLTS:150:BLEM.PROC PP")
    field(LNK8, "QUAD:SLTS:150:BMOD.PROC PP")
    field(LNK9, "QUAD:SLTS:150:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SLTS:150:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SLTS:150:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SLTS:150:BMAX")
  field(DOL2, "QUAD:SLTS:150:BMAX")
  field(DOL3, "QUAD:SLTS:150:BMAX")
  field(DOL4, "QUAD:SLTS:150:BMIN")
  field(DOL5, "QUAD:SLTS:150:BMIN")
  field(DOL6, "QUAD:SLTS:150:BMIN")
  field(LNK1, "QUAD:SLTS:150:BMAGX.HOPR")
  field(LNK2, "QUAD:SLTS:150:BMAGY.HOPR")
  field(LNK3, "QUAD:SLTS:150:BLEM.HOPR")
  field(LNK4, "QUAD:SLTS:150:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SLTS:150:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SLTS:150:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SLTS:150:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SLTS:150:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SLTS:150:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SLTS:150:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SLTS:150:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTS:150:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTS:150:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SLTS:150:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTS:150:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SLTS:150:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SLTS:150:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SLTS:150:EDES NPP MS")
  field(INPB, "QUAD:SLTS:150:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SLTS:180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTS:1:CTRL.RVAL")
  field(LNK1, "QUAD:SLTS:180:FUNC CA PP")
  field(DOL2, "MGNT:SLTS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SLTS:180:FUNC CA PP")
  field(DOL3, "MGNT:SLTS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SLTS:180:FUNC CA PP")
  field(DOL4, "MGNT:SLTS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SLTS:180:FUNC CA PP")
  field(DOL5, "MGNT:SLTS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SLTS:180:FUNC CA PP")
  field(DOL6, "MGNT:SLTS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SLTS:180:FUNC CA PP")
  field(DOL7, "MGNT:SLTS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SLTS:180:FUNC CA PP")
  field(DOL8, "MGNT:SLTS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SLTS:180:FUNC CA PP")
  field(DOL9, "MGNT:SLTS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SLTS:180:FUNC CA PP")
  field(DOLA, "MGNT:SLTS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SLTS:180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SLTS:180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SLTS:180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SLTS:180:EDES.PROC PP")
    field(LNK2, "QUAD:SLTS:180:EACT.PROC PP")
    field(LNK3, "QUAD:SLTS:180:EERR.DISA PP")
    field(LNK4, "QUAD:SLTS:180:ECON.PROC PP")
    field(LNK5, "QUAD:SLTS:180:BMAGX.PROC PP")
    field(LNK6, "QUAD:SLTS:180:BMAGY.PROC PP")
    field(LNK7, "QUAD:SLTS:180:BLEM.PROC PP")
    field(LNK8, "QUAD:SLTS:180:BMOD.PROC PP")
    field(LNK9, "QUAD:SLTS:180:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SLTS:180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SLTS:180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SLTS:180:BMAX")
  field(DOL2, "QUAD:SLTS:180:BMAX")
  field(DOL3, "QUAD:SLTS:180:BMAX")
  field(DOL4, "QUAD:SLTS:180:BMIN")
  field(DOL5, "QUAD:SLTS:180:BMIN")
  field(DOL6, "QUAD:SLTS:180:BMIN")
  field(LNK1, "QUAD:SLTS:180:BMAGX.HOPR")
  field(LNK2, "QUAD:SLTS:180:BMAGY.HOPR")
  field(LNK3, "QUAD:SLTS:180:BLEM.HOPR")
  field(LNK4, "QUAD:SLTS:180:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SLTS:180:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SLTS:180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SLTS:180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SLTS:180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SLTS:180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SLTS:180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SLTS:180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTS:180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTS:180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SLTS:180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTS:180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SLTS:180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SLTS:180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SLTS:180:EDES NPP MS")
  field(INPB, "QUAD:SLTS:180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SLTS:430:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTS:1:CTRL.RVAL")
  field(LNK1, "QUAD:SLTS:430:FUNC CA PP")
  field(DOL2, "MGNT:SLTS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SLTS:430:FUNC CA PP")
  field(DOL3, "MGNT:SLTS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SLTS:430:FUNC CA PP")
  field(DOL4, "MGNT:SLTS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SLTS:430:FUNC CA PP")
  field(DOL5, "MGNT:SLTS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SLTS:430:FUNC CA PP")
  field(DOL6, "MGNT:SLTS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SLTS:430:FUNC CA PP")
  field(DOL7, "MGNT:SLTS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SLTS:430:FUNC CA PP")
  field(DOL8, "MGNT:SLTS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SLTS:430:FUNC CA PP")
  field(DOL9, "MGNT:SLTS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SLTS:430:FUNC CA PP")
  field(DOLA, "MGNT:SLTS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SLTS:430:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SLTS:430:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SLTS:430:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SLTS:430:EDES.PROC PP")
    field(LNK2, "QUAD:SLTS:430:EACT.PROC PP")
    field(LNK3, "QUAD:SLTS:430:EERR.DISA PP")
    field(LNK4, "QUAD:SLTS:430:ECON.PROC PP")
    field(LNK5, "QUAD:SLTS:430:BMAGX.PROC PP")
    field(LNK6, "QUAD:SLTS:430:BMAGY.PROC PP")
    field(LNK7, "QUAD:SLTS:430:BLEM.PROC PP")
    field(LNK8, "QUAD:SLTS:430:BMOD.PROC PP")
    field(LNK9, "QUAD:SLTS:430:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SLTS:430:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SLTS:430:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SLTS:430:BMAX")
  field(DOL2, "QUAD:SLTS:430:BMAX")
  field(DOL3, "QUAD:SLTS:430:BMAX")
  field(DOL4, "QUAD:SLTS:430:BMIN")
  field(DOL5, "QUAD:SLTS:430:BMIN")
  field(DOL6, "QUAD:SLTS:430:BMIN")
  field(LNK1, "QUAD:SLTS:430:BMAGX.HOPR")
  field(LNK2, "QUAD:SLTS:430:BMAGY.HOPR")
  field(LNK3, "QUAD:SLTS:430:BLEM.HOPR")
  field(LNK4, "QUAD:SLTS:430:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SLTS:430:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SLTS:430:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SLTS:430:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SLTS:430:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SLTS:430:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SLTS:430:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SLTS:430:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTS:430:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTS:430:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SLTS:430:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTS:430:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SLTS:430:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SLTS:430:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SLTS:430:EDES NPP MS")
  field(INPB, "QUAD:SLTS:430:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SLTS:460:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTS:1:CTRL.RVAL")
  field(LNK1, "QUAD:SLTS:460:FUNC CA PP")
  field(DOL2, "MGNT:SLTS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SLTS:460:FUNC CA PP")
  field(DOL3, "MGNT:SLTS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SLTS:460:FUNC CA PP")
  field(DOL4, "MGNT:SLTS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SLTS:460:FUNC CA PP")
  field(DOL5, "MGNT:SLTS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SLTS:460:FUNC CA PP")
  field(DOL6, "MGNT:SLTS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SLTS:460:FUNC CA PP")
  field(DOL7, "MGNT:SLTS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SLTS:460:FUNC CA PP")
  field(DOL8, "MGNT:SLTS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SLTS:460:FUNC CA PP")
  field(DOL9, "MGNT:SLTS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SLTS:460:FUNC CA PP")
  field(DOLA, "MGNT:SLTS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SLTS:460:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SLTS:460:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SLTS:460:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SLTS:460:EDES.PROC PP")
    field(LNK2, "QUAD:SLTS:460:EACT.PROC PP")
    field(LNK3, "QUAD:SLTS:460:EERR.DISA PP")
    field(LNK4, "QUAD:SLTS:460:ECON.PROC PP")
    field(LNK5, "QUAD:SLTS:460:BMAGX.PROC PP")
    field(LNK6, "QUAD:SLTS:460:BMAGY.PROC PP")
    field(LNK7, "QUAD:SLTS:460:BLEM.PROC PP")
    field(LNK8, "QUAD:SLTS:460:BMOD.PROC PP")
    field(LNK9, "QUAD:SLTS:460:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SLTS:460:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SLTS:460:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SLTS:460:BMAX")
  field(DOL2, "QUAD:SLTS:460:BMAX")
  field(DOL3, "QUAD:SLTS:460:BMAX")
  field(DOL4, "QUAD:SLTS:460:BMIN")
  field(DOL5, "QUAD:SLTS:460:BMIN")
  field(DOL6, "QUAD:SLTS:460:BMIN")
  field(LNK1, "QUAD:SLTS:460:BMAGX.HOPR")
  field(LNK2, "QUAD:SLTS:460:BMAGY.HOPR")
  field(LNK3, "QUAD:SLTS:460:BLEM.HOPR")
  field(LNK4, "QUAD:SLTS:460:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SLTS:460:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SLTS:460:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SLTS:460:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SLTS:460:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SLTS:460:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SLTS:460:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SLTS:460:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTS:460:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTS:460:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SLTS:460:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTS:460:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SLTS:460:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SLTS:460:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SLTS:460:EDES NPP MS")
  field(INPB, "QUAD:SLTS:460:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SLTS:182:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTS:1:CTRL.RVAL")
  field(LNK1, "XCOR:SLTS:182:FUNC CA PP")
  field(DOL2, "MGNT:SLTS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SLTS:182:FUNC CA PP")
  field(DOL3, "MGNT:SLTS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SLTS:182:FUNC CA PP")
  field(DOL4, "MGNT:SLTS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SLTS:182:FUNC CA PP")
  field(DOL5, "MGNT:SLTS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SLTS:182:FUNC CA PP")
  field(DOL6, "MGNT:SLTS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SLTS:182:FUNC CA PP")
  field(DOL7, "MGNT:SLTS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SLTS:182:FUNC CA PP")
  field(DOL8, "MGNT:SLTS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SLTS:182:FUNC CA PP")
  field(DOL9, "MGNT:SLTS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SLTS:182:FUNC CA PP")
  field(DOLA, "MGNT:SLTS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SLTS:182:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SLTS:182:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SLTS:182:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SLTS:182:EDES.PROC PP")
    field(LNK2, "XCOR:SLTS:182:EACT.PROC PP")
    field(LNK3, "XCOR:SLTS:182:EERR.DISA PP")
    field(LNK4, "XCOR:SLTS:182:ECON.PROC PP")
    field(LNK5, "XCOR:SLTS:182:BMAGX.PROC PP")
    field(LNK6, "XCOR:SLTS:182:BMAGY.PROC PP")
    field(LNK7, "XCOR:SLTS:182:BLEM.PROC PP")
    field(LNK8, "XCOR:SLTS:182:BMOD.PROC PP")
    field(LNK9, "XCOR:SLTS:182:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SLTS:182:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SLTS:182:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SLTS:182:BMAX")
  field(DOL2, "XCOR:SLTS:182:BMAX")
  field(DOL3, "XCOR:SLTS:182:BMAX")
  field(DOL4, "XCOR:SLTS:182:BMIN")
  field(DOL5, "XCOR:SLTS:182:BMIN")
  field(DOL6, "XCOR:SLTS:182:BMIN")
  field(LNK1, "XCOR:SLTS:182:BMAGX.HOPR")
  field(LNK2, "XCOR:SLTS:182:BMAGY.HOPR")
  field(LNK3, "XCOR:SLTS:182:BLEM.HOPR")
  field(LNK4, "XCOR:SLTS:182:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SLTS:182:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SLTS:182:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SLTS:182:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SLTS:182:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SLTS:182:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SLTS:182:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SLTS:182:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SLTS:182:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SLTS:182:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SLTS:182:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SLTS:182:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SLTS:182:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SLTS:182:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SLTS:182:EDES NPP MS")
  field(INPB, "XCOR:SLTS:182:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SLTS:442:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTS:1:CTRL.RVAL")
  field(LNK1, "XCOR:SLTS:442:FUNC CA PP")
  field(DOL2, "MGNT:SLTS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SLTS:442:FUNC CA PP")
  field(DOL3, "MGNT:SLTS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SLTS:442:FUNC CA PP")
  field(DOL4, "MGNT:SLTS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SLTS:442:FUNC CA PP")
  field(DOL5, "MGNT:SLTS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SLTS:442:FUNC CA PP")
  field(DOL6, "MGNT:SLTS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SLTS:442:FUNC CA PP")
  field(DOL7, "MGNT:SLTS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SLTS:442:FUNC CA PP")
  field(DOL8, "MGNT:SLTS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SLTS:442:FUNC CA PP")
  field(DOL9, "MGNT:SLTS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SLTS:442:FUNC CA PP")
  field(DOLA, "MGNT:SLTS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SLTS:442:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SLTS:442:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SLTS:442:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SLTS:442:EDES.PROC PP")
    field(LNK2, "XCOR:SLTS:442:EACT.PROC PP")
    field(LNK3, "XCOR:SLTS:442:EERR.DISA PP")
    field(LNK4, "XCOR:SLTS:442:ECON.PROC PP")
    field(LNK5, "XCOR:SLTS:442:BMAGX.PROC PP")
    field(LNK6, "XCOR:SLTS:442:BMAGY.PROC PP")
    field(LNK7, "XCOR:SLTS:442:BLEM.PROC PP")
    field(LNK8, "XCOR:SLTS:442:BMOD.PROC PP")
    field(LNK9, "XCOR:SLTS:442:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SLTS:442:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SLTS:442:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SLTS:442:BMAX")
  field(DOL2, "XCOR:SLTS:442:BMAX")
  field(DOL3, "XCOR:SLTS:442:BMAX")
  field(DOL4, "XCOR:SLTS:442:BMIN")
  field(DOL5, "XCOR:SLTS:442:BMIN")
  field(DOL6, "XCOR:SLTS:442:BMIN")
  field(LNK1, "XCOR:SLTS:442:BMAGX.HOPR")
  field(LNK2, "XCOR:SLTS:442:BMAGY.HOPR")
  field(LNK3, "XCOR:SLTS:442:BLEM.HOPR")
  field(LNK4, "XCOR:SLTS:442:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SLTS:442:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SLTS:442:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SLTS:442:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SLTS:442:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SLTS:442:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SLTS:442:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SLTS:442:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SLTS:442:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SLTS:442:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SLTS:442:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SLTS:442:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SLTS:442:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SLTS:442:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SLTS:442:EDES NPP MS")
  field(INPB, "XCOR:SLTS:442:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SLTS:468:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTS:1:CTRL.RVAL")
  field(LNK1, "XCOR:SLTS:468:FUNC CA PP")
  field(DOL2, "MGNT:SLTS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SLTS:468:FUNC CA PP")
  field(DOL3, "MGNT:SLTS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SLTS:468:FUNC CA PP")
  field(DOL4, "MGNT:SLTS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SLTS:468:FUNC CA PP")
  field(DOL5, "MGNT:SLTS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SLTS:468:FUNC CA PP")
  field(DOL6, "MGNT:SLTS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SLTS:468:FUNC CA PP")
  field(DOL7, "MGNT:SLTS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SLTS:468:FUNC CA PP")
  field(DOL8, "MGNT:SLTS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SLTS:468:FUNC CA PP")
  field(DOL9, "MGNT:SLTS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SLTS:468:FUNC CA PP")
  field(DOLA, "MGNT:SLTS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SLTS:468:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SLTS:468:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SLTS:468:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SLTS:468:EDES.PROC PP")
    field(LNK2, "XCOR:SLTS:468:EACT.PROC PP")
    field(LNK3, "XCOR:SLTS:468:EERR.DISA PP")
    field(LNK4, "XCOR:SLTS:468:ECON.PROC PP")
    field(LNK5, "XCOR:SLTS:468:BMAGX.PROC PP")
    field(LNK6, "XCOR:SLTS:468:BMAGY.PROC PP")
    field(LNK7, "XCOR:SLTS:468:BLEM.PROC PP")
    field(LNK8, "XCOR:SLTS:468:BMOD.PROC PP")
    field(LNK9, "XCOR:SLTS:468:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SLTS:468:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SLTS:468:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SLTS:468:BMAX")
  field(DOL2, "XCOR:SLTS:468:BMAX")
  field(DOL3, "XCOR:SLTS:468:BMAX")
  field(DOL4, "XCOR:SLTS:468:BMIN")
  field(DOL5, "XCOR:SLTS:468:BMIN")
  field(DOL6, "XCOR:SLTS:468:BMIN")
  field(LNK1, "XCOR:SLTS:468:BMAGX.HOPR")
  field(LNK2, "XCOR:SLTS:468:BMAGY.HOPR")
  field(LNK3, "XCOR:SLTS:468:BLEM.HOPR")
  field(LNK4, "XCOR:SLTS:468:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SLTS:468:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SLTS:468:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SLTS:468:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SLTS:468:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SLTS:468:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SLTS:468:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SLTS:468:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SLTS:468:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SLTS:468:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SLTS:468:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SLTS:468:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SLTS:468:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SLTS:468:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SLTS:468:EDES NPP MS")
  field(INPB, "XCOR:SLTS:468:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SLTS:183:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTS:1:CTRL.RVAL")
  field(LNK1, "YCOR:SLTS:183:FUNC CA PP")
  field(DOL2, "MGNT:SLTS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SLTS:183:FUNC CA PP")
  field(DOL3, "MGNT:SLTS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SLTS:183:FUNC CA PP")
  field(DOL4, "MGNT:SLTS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SLTS:183:FUNC CA PP")
  field(DOL5, "MGNT:SLTS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SLTS:183:FUNC CA PP")
  field(DOL6, "MGNT:SLTS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SLTS:183:FUNC CA PP")
  field(DOL7, "MGNT:SLTS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SLTS:183:FUNC CA PP")
  field(DOL8, "MGNT:SLTS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SLTS:183:FUNC CA PP")
  field(DOL9, "MGNT:SLTS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SLTS:183:FUNC CA PP")
  field(DOLA, "MGNT:SLTS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SLTS:183:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SLTS:183:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SLTS:183:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SLTS:183:EDES.PROC PP")
    field(LNK2, "YCOR:SLTS:183:EACT.PROC PP")
    field(LNK3, "YCOR:SLTS:183:EERR.DISA PP")
    field(LNK4, "YCOR:SLTS:183:ECON.PROC PP")
    field(LNK5, "YCOR:SLTS:183:BMAGX.PROC PP")
    field(LNK6, "YCOR:SLTS:183:BMAGY.PROC PP")
    field(LNK7, "YCOR:SLTS:183:BLEM.PROC PP")
    field(LNK8, "YCOR:SLTS:183:BMOD.PROC PP")
    field(LNK9, "YCOR:SLTS:183:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SLTS:183:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SLTS:183:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SLTS:183:BMAX")
  field(DOL2, "YCOR:SLTS:183:BMAX")
  field(DOL3, "YCOR:SLTS:183:BMAX")
  field(DOL4, "YCOR:SLTS:183:BMIN")
  field(DOL5, "YCOR:SLTS:183:BMIN")
  field(DOL6, "YCOR:SLTS:183:BMIN")
  field(LNK1, "YCOR:SLTS:183:BMAGX.HOPR")
  field(LNK2, "YCOR:SLTS:183:BMAGY.HOPR")
  field(LNK3, "YCOR:SLTS:183:BLEM.HOPR")
  field(LNK4, "YCOR:SLTS:183:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SLTS:183:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SLTS:183:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SLTS:183:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SLTS:183:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SLTS:183:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SLTS:183:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SLTS:183:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SLTS:183:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SLTS:183:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SLTS:183:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SLTS:183:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SLTS:183:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SLTS:183:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SLTS:183:EDES NPP MS")
  field(INPB, "YCOR:SLTS:183:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SLTS:443:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTS:1:CTRL.RVAL")
  field(LNK1, "YCOR:SLTS:443:FUNC CA PP")
  field(DOL2, "MGNT:SLTS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SLTS:443:FUNC CA PP")
  field(DOL3, "MGNT:SLTS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SLTS:443:FUNC CA PP")
  field(DOL4, "MGNT:SLTS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SLTS:443:FUNC CA PP")
  field(DOL5, "MGNT:SLTS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SLTS:443:FUNC CA PP")
  field(DOL6, "MGNT:SLTS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SLTS:443:FUNC CA PP")
  field(DOL7, "MGNT:SLTS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SLTS:443:FUNC CA PP")
  field(DOL8, "MGNT:SLTS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SLTS:443:FUNC CA PP")
  field(DOL9, "MGNT:SLTS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SLTS:443:FUNC CA PP")
  field(DOLA, "MGNT:SLTS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SLTS:443:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SLTS:443:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SLTS:443:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SLTS:443:EDES.PROC PP")
    field(LNK2, "YCOR:SLTS:443:EACT.PROC PP")
    field(LNK3, "YCOR:SLTS:443:EERR.DISA PP")
    field(LNK4, "YCOR:SLTS:443:ECON.PROC PP")
    field(LNK5, "YCOR:SLTS:443:BMAGX.PROC PP")
    field(LNK6, "YCOR:SLTS:443:BMAGY.PROC PP")
    field(LNK7, "YCOR:SLTS:443:BLEM.PROC PP")
    field(LNK8, "YCOR:SLTS:443:BMOD.PROC PP")
    field(LNK9, "YCOR:SLTS:443:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SLTS:443:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SLTS:443:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SLTS:443:BMAX")
  field(DOL2, "YCOR:SLTS:443:BMAX")
  field(DOL3, "YCOR:SLTS:443:BMAX")
  field(DOL4, "YCOR:SLTS:443:BMIN")
  field(DOL5, "YCOR:SLTS:443:BMIN")
  field(DOL6, "YCOR:SLTS:443:BMIN")
  field(LNK1, "YCOR:SLTS:443:BMAGX.HOPR")
  field(LNK2, "YCOR:SLTS:443:BMAGY.HOPR")
  field(LNK3, "YCOR:SLTS:443:BLEM.HOPR")
  field(LNK4, "YCOR:SLTS:443:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SLTS:443:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SLTS:443:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SLTS:443:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SLTS:443:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SLTS:443:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SLTS:443:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SLTS:443:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SLTS:443:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SLTS:443:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SLTS:443:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SLTS:443:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SLTS:443:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SLTS:443:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SLTS:443:EDES NPP MS")
  field(INPB, "YCOR:SLTS:443:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SLTS:469:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTS:1:CTRL.RVAL")
  field(LNK1, "YCOR:SLTS:469:FUNC CA PP")
  field(DOL2, "MGNT:SLTS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SLTS:469:FUNC CA PP")
  field(DOL3, "MGNT:SLTS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SLTS:469:FUNC CA PP")
  field(DOL4, "MGNT:SLTS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SLTS:469:FUNC CA PP")
  field(DOL5, "MGNT:SLTS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SLTS:469:FUNC CA PP")
  field(DOL6, "MGNT:SLTS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SLTS:469:FUNC CA PP")
  field(DOL7, "MGNT:SLTS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SLTS:469:FUNC CA PP")
  field(DOL8, "MGNT:SLTS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SLTS:469:FUNC CA PP")
  field(DOL9, "MGNT:SLTS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SLTS:469:FUNC CA PP")
  field(DOLA, "MGNT:SLTS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SLTS:469:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SLTS:469:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SLTS:469:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SLTS:469:EDES.PROC PP")
    field(LNK2, "YCOR:SLTS:469:EACT.PROC PP")
    field(LNK3, "YCOR:SLTS:469:EERR.DISA PP")
    field(LNK4, "YCOR:SLTS:469:ECON.PROC PP")
    field(LNK5, "YCOR:SLTS:469:BMAGX.PROC PP")
    field(LNK6, "YCOR:SLTS:469:BMAGY.PROC PP")
    field(LNK7, "YCOR:SLTS:469:BLEM.PROC PP")
    field(LNK8, "YCOR:SLTS:469:BMOD.PROC PP")
    field(LNK9, "YCOR:SLTS:469:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SLTS:469:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SLTS:469:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SLTS:469:BMAX")
  field(DOL2, "YCOR:SLTS:469:BMAX")
  field(DOL3, "YCOR:SLTS:469:BMAX")
  field(DOL4, "YCOR:SLTS:469:BMIN")
  field(DOL5, "YCOR:SLTS:469:BMIN")
  field(DOL6, "YCOR:SLTS:469:BMIN")
  field(LNK1, "YCOR:SLTS:469:BMAGX.HOPR")
  field(LNK2, "YCOR:SLTS:469:BMAGY.HOPR")
  field(LNK3, "YCOR:SLTS:469:BLEM.HOPR")
  field(LNK4, "YCOR:SLTS:469:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SLTS:469:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SLTS:469:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SLTS:469:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SLTS:469:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SLTS:469:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SLTS:469:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SLTS:469:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SLTS:469:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SLTS:469:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SLTS:469:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SLTS:469:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SLTS:469:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SLTS:469:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SLTS:469:EDES NPP MS")
  field(INPB, "YCOR:SLTS:469:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SLTD:628:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTD:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTD:1:CTRL.RVAL")
  field(LNK1, "XCOR:SLTD:628:FUNC CA PP")
  field(DOL2, "MGNT:SLTD:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SLTD:628:FUNC CA PP")
  field(DOL3, "MGNT:SLTD:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SLTD:628:FUNC CA PP")
  field(DOL4, "MGNT:SLTD:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SLTD:628:FUNC CA PP")
  field(DOL5, "MGNT:SLTD:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SLTD:628:FUNC CA PP")
  field(DOL6, "MGNT:SLTD:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SLTD:628:FUNC CA PP")
  field(DOL7, "MGNT:SLTD:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SLTD:628:FUNC CA PP")
  field(DOL8, "MGNT:SLTD:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SLTD:628:FUNC CA PP")
  field(DOL9, "MGNT:SLTD:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SLTD:628:FUNC CA PP")
  field(DOLA, "MGNT:SLTD:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SLTD:628:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SLTD:628:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SLTD:628:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SLTD:628:EDES.PROC PP")
    field(LNK2, "XCOR:SLTD:628:EACT.PROC PP")
    field(LNK3, "XCOR:SLTD:628:EERR.DISA PP")
    field(LNK4, "XCOR:SLTD:628:ECON.PROC PP")
    field(LNK5, "XCOR:SLTD:628:BMAGX.PROC PP")
    field(LNK6, "XCOR:SLTD:628:BMAGY.PROC PP")
    field(LNK7, "XCOR:SLTD:628:BLEM.PROC PP")
    field(LNK8, "XCOR:SLTD:628:BMOD.PROC PP")
    field(LNK9, "XCOR:SLTD:628:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SLTD:628:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SLTD:628:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SLTD:628:BMAX")
  field(DOL2, "XCOR:SLTD:628:BMAX")
  field(DOL3, "XCOR:SLTD:628:BMAX")
  field(DOL4, "XCOR:SLTD:628:BMIN")
  field(DOL5, "XCOR:SLTD:628:BMIN")
  field(DOL6, "XCOR:SLTD:628:BMIN")
  field(LNK1, "XCOR:SLTD:628:BMAGX.HOPR")
  field(LNK2, "XCOR:SLTD:628:BMAGY.HOPR")
  field(LNK3, "XCOR:SLTD:628:BLEM.HOPR")
  field(LNK4, "XCOR:SLTD:628:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SLTD:628:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SLTD:628:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SLTD:628:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SLTD:628:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SLTD:628:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SLTD:628:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SLTD:628:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SLTD:628:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SLTD:628:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SLTD:628:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SLTD:628:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SLTD:628:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SLTD:628:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SLTD:628:EDES NPP MS")
  field(INPB, "XCOR:SLTD:628:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SLTD:631:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTD:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTD:1:CTRL.RVAL")
  field(LNK1, "YCOR:SLTD:631:FUNC CA PP")
  field(DOL2, "MGNT:SLTD:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SLTD:631:FUNC CA PP")
  field(DOL3, "MGNT:SLTD:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SLTD:631:FUNC CA PP")
  field(DOL4, "MGNT:SLTD:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SLTD:631:FUNC CA PP")
  field(DOL5, "MGNT:SLTD:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SLTD:631:FUNC CA PP")
  field(DOL6, "MGNT:SLTD:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SLTD:631:FUNC CA PP")
  field(DOL7, "MGNT:SLTD:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SLTD:631:FUNC CA PP")
  field(DOL8, "MGNT:SLTD:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SLTD:631:FUNC CA PP")
  field(DOL9, "MGNT:SLTD:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SLTD:631:FUNC CA PP")
  field(DOLA, "MGNT:SLTD:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SLTD:631:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SLTD:631:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SLTD:631:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SLTD:631:EDES.PROC PP")
    field(LNK2, "YCOR:SLTD:631:EACT.PROC PP")
    field(LNK3, "YCOR:SLTD:631:EERR.DISA PP")
    field(LNK4, "YCOR:SLTD:631:ECON.PROC PP")
    field(LNK5, "YCOR:SLTD:631:BMAGX.PROC PP")
    field(LNK6, "YCOR:SLTD:631:BMAGY.PROC PP")
    field(LNK7, "YCOR:SLTD:631:BLEM.PROC PP")
    field(LNK8, "YCOR:SLTD:631:BMOD.PROC PP")
    field(LNK9, "YCOR:SLTD:631:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SLTD:631:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SLTD:631:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SLTD:631:BMAX")
  field(DOL2, "YCOR:SLTD:631:BMAX")
  field(DOL3, "YCOR:SLTD:631:BMAX")
  field(DOL4, "YCOR:SLTD:631:BMIN")
  field(DOL5, "YCOR:SLTD:631:BMIN")
  field(DOL6, "YCOR:SLTD:631:BMIN")
  field(LNK1, "YCOR:SLTD:631:BMAGX.HOPR")
  field(LNK2, "YCOR:SLTD:631:BMAGY.HOPR")
  field(LNK3, "YCOR:SLTD:631:BLEM.HOPR")
  field(LNK4, "YCOR:SLTD:631:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SLTD:631:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SLTD:631:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SLTD:631:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SLTD:631:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SLTD:631:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SLTD:631:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SLTD:631:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SLTD:631:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SLTD:631:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SLTD:631:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SLTD:631:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SLTD:631:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SLTD:631:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SLTD:631:EDES NPP MS")
  field(INPB, "YCOR:SLTD:631:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:CLTH:140:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "QUAD:CLTH:140:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "QUAD:CLTH:140:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:CLTH:140:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:CLTH:140:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "QUAD:CLTH:140:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "QUAD:CLTH:140:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "QUAD:CLTH:140:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:CLTH:140:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "QUAD:CLTH:140:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:CLTH:140:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:CLTH:140:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:CLTH:140:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:CLTH:140:EDES.PROC PP")
    field(LNK2, "QUAD:CLTH:140:EACT.PROC PP")
    field(LNK3, "QUAD:CLTH:140:EERR.DISA PP")
    field(LNK4, "QUAD:CLTH:140:ECON.PROC PP")
    field(LNK5, "QUAD:CLTH:140:BMAGX.PROC PP")
    field(LNK6, "QUAD:CLTH:140:BMAGY.PROC PP")
    field(LNK7, "QUAD:CLTH:140:BLEM.PROC PP")
    field(LNK8, "QUAD:CLTH:140:BMOD.PROC PP")
    field(LNK9, "QUAD:CLTH:140:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:CLTH:140:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:CLTH:140:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:CLTH:140:BMAX")
  field(DOL2, "QUAD:CLTH:140:BMAX")
  field(DOL3, "QUAD:CLTH:140:BMAX")
  field(DOL4, "QUAD:CLTH:140:BMIN")
  field(DOL5, "QUAD:CLTH:140:BMIN")
  field(DOL6, "QUAD:CLTH:140:BMIN")
  field(LNK1, "QUAD:CLTH:140:BMAGX.HOPR")
  field(LNK2, "QUAD:CLTH:140:BMAGY.HOPR")
  field(LNK3, "QUAD:CLTH:140:BLEM.HOPR")
  field(LNK4, "QUAD:CLTH:140:BMAGX.LOPR PP")
  field(LNK5, "QUAD:CLTH:140:BMAGY.LOPR PP")
  field(LNK6, "QUAD:CLTH:140:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTH:140:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTH:140:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:CLTH:140:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:CLTH:140:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:CLTH:140:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTH:140:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTH:140:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTH:140:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTH:140:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTH:140:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:CLTH:140:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:CLTH:140:EDES NPP MS")
  field(INPB, "QUAD:CLTH:140:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:CLTH:170:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "QUAD:CLTH:170:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "QUAD:CLTH:170:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:CLTH:170:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:CLTH:170:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "QUAD:CLTH:170:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "QUAD:CLTH:170:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "QUAD:CLTH:170:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:CLTH:170:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "QUAD:CLTH:170:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:CLTH:170:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:CLTH:170:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:CLTH:170:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:CLTH:170:EDES.PROC PP")
    field(LNK2, "QUAD:CLTH:170:EACT.PROC PP")
    field(LNK3, "QUAD:CLTH:170:EERR.DISA PP")
    field(LNK4, "QUAD:CLTH:170:ECON.PROC PP")
    field(LNK5, "QUAD:CLTH:170:BMAGX.PROC PP")
    field(LNK6, "QUAD:CLTH:170:BMAGY.PROC PP")
    field(LNK7, "QUAD:CLTH:170:BLEM.PROC PP")
    field(LNK8, "QUAD:CLTH:170:BMOD.PROC PP")
    field(LNK9, "QUAD:CLTH:170:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:CLTH:170:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:CLTH:170:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:CLTH:170:BMAX")
  field(DOL2, "QUAD:CLTH:170:BMAX")
  field(DOL3, "QUAD:CLTH:170:BMAX")
  field(DOL4, "QUAD:CLTH:170:BMIN")
  field(DOL5, "QUAD:CLTH:170:BMIN")
  field(DOL6, "QUAD:CLTH:170:BMIN")
  field(LNK1, "QUAD:CLTH:170:BMAGX.HOPR")
  field(LNK2, "QUAD:CLTH:170:BMAGY.HOPR")
  field(LNK3, "QUAD:CLTH:170:BLEM.HOPR")
  field(LNK4, "QUAD:CLTH:170:BMAGX.LOPR PP")
  field(LNK5, "QUAD:CLTH:170:BMAGY.LOPR PP")
  field(LNK6, "QUAD:CLTH:170:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTH:170:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTH:170:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:CLTH:170:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:CLTH:170:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:CLTH:170:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTH:170:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTH:170:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTH:170:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTH:170:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTH:170:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:CLTH:170:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:CLTH:170:EDES NPP MS")
  field(INPB, "QUAD:CLTH:170:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:CLTH:168:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "XCOR:CLTH:168:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "XCOR:CLTH:168:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:CLTH:168:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:CLTH:168:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "XCOR:CLTH:168:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "XCOR:CLTH:168:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "XCOR:CLTH:168:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:CLTH:168:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "XCOR:CLTH:168:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:CLTH:168:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:CLTH:168:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:CLTH:168:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:CLTH:168:EDES.PROC PP")
    field(LNK2, "XCOR:CLTH:168:EACT.PROC PP")
    field(LNK3, "XCOR:CLTH:168:EERR.DISA PP")
    field(LNK4, "XCOR:CLTH:168:ECON.PROC PP")
    field(LNK5, "XCOR:CLTH:168:BMAGX.PROC PP")
    field(LNK6, "XCOR:CLTH:168:BMAGY.PROC PP")
    field(LNK7, "XCOR:CLTH:168:BLEM.PROC PP")
    field(LNK8, "XCOR:CLTH:168:BMOD.PROC PP")
    field(LNK9, "XCOR:CLTH:168:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:CLTH:168:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:CLTH:168:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:CLTH:168:BMAX")
  field(DOL2, "XCOR:CLTH:168:BMAX")
  field(DOL3, "XCOR:CLTH:168:BMAX")
  field(DOL4, "XCOR:CLTH:168:BMIN")
  field(DOL5, "XCOR:CLTH:168:BMIN")
  field(DOL6, "XCOR:CLTH:168:BMIN")
  field(LNK1, "XCOR:CLTH:168:BMAGX.HOPR")
  field(LNK2, "XCOR:CLTH:168:BMAGY.HOPR")
  field(LNK3, "XCOR:CLTH:168:BLEM.HOPR")
  field(LNK4, "XCOR:CLTH:168:BMAGX.LOPR PP")
  field(LNK5, "XCOR:CLTH:168:BMAGY.LOPR PP")
  field(LNK6, "XCOR:CLTH:168:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:CLTH:168:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:CLTH:168:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:CLTH:168:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:CLTH:168:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:CLTH:168:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:CLTH:168:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:CLTH:168:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:CLTH:168:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:CLTH:168:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:CLTH:168:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:CLTH:168:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:CLTH:168:EDES NPP MS")
  field(INPB, "XCOR:CLTH:168:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:CLTH:133:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "YCOR:CLTH:133:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "YCOR:CLTH:133:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:CLTH:133:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:CLTH:133:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "YCOR:CLTH:133:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "YCOR:CLTH:133:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "YCOR:CLTH:133:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:CLTH:133:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "YCOR:CLTH:133:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:CLTH:133:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:CLTH:133:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:CLTH:133:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:CLTH:133:EDES.PROC PP")
    field(LNK2, "YCOR:CLTH:133:EACT.PROC PP")
    field(LNK3, "YCOR:CLTH:133:EERR.DISA PP")
    field(LNK4, "YCOR:CLTH:133:ECON.PROC PP")
    field(LNK5, "YCOR:CLTH:133:BMAGX.PROC PP")
    field(LNK6, "YCOR:CLTH:133:BMAGY.PROC PP")
    field(LNK7, "YCOR:CLTH:133:BLEM.PROC PP")
    field(LNK8, "YCOR:CLTH:133:BMOD.PROC PP")
    field(LNK9, "YCOR:CLTH:133:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:CLTH:133:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:CLTH:133:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:CLTH:133:BMAX")
  field(DOL2, "YCOR:CLTH:133:BMAX")
  field(DOL3, "YCOR:CLTH:133:BMAX")
  field(DOL4, "YCOR:CLTH:133:BMIN")
  field(DOL5, "YCOR:CLTH:133:BMIN")
  field(DOL6, "YCOR:CLTH:133:BMIN")
  field(LNK1, "YCOR:CLTH:133:BMAGX.HOPR")
  field(LNK2, "YCOR:CLTH:133:BMAGY.HOPR")
  field(LNK3, "YCOR:CLTH:133:BLEM.HOPR")
  field(LNK4, "YCOR:CLTH:133:BMAGX.LOPR PP")
  field(LNK5, "YCOR:CLTH:133:BMAGY.LOPR PP")
  field(LNK6, "YCOR:CLTH:133:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:CLTH:133:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:CLTH:133:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:CLTH:133:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:CLTH:133:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:CLTH:133:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTH:133:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTH:133:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:CLTH:133:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTH:133:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:CLTH:133:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:CLTH:133:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:CLTH:133:EDES NPP MS")
  field(INPB, "YCOR:CLTH:133:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:CLTS:185:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "KICK:CLTS:185:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "KICK:CLTS:185:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "KICK:CLTS:185:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "KICK:CLTS:185:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "KICK:CLTS:185:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "KICK:CLTS:185:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "KICK:CLTS:185:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "KICK:CLTS:185:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "KICK:CLTS:185:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "KICK:CLTS:185:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:CLTS:185:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:CLTS:185:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:CLTS:185:EDES.PROC PP")
    field(LNK2, "KICK:CLTS:185:EACT.PROC PP")
    field(LNK3, "KICK:CLTS:185:EERR.DISA PP")
    field(LNK4, "KICK:CLTS:185:ECON.PROC PP")
    field(LNK5, "KICK:CLTS:185:BMAGX.PROC PP")
    field(LNK6, "KICK:CLTS:185:BMAGY.PROC PP")
    field(LNK7, "KICK:CLTS:185:BLEM.PROC PP")
    field(LNK8, "KICK:CLTS:185:BMOD.PROC PP")
    field(LNK9, "KICK:CLTS:185:EDESSAVE.PROC PP")
    field(LNKA, "KICK:CLTS:185:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:CLTS:185:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:CLTS:185:BMAX")
  field(DOL2, "KICK:CLTS:185:BMAX")
  field(DOL3, "KICK:CLTS:185:BMAX")
  field(DOL4, "KICK:CLTS:185:BMIN")
  field(DOL5, "KICK:CLTS:185:BMIN")
  field(DOL6, "KICK:CLTS:185:BMIN")
  field(LNK1, "KICK:CLTS:185:BMAGX.HOPR")
  field(LNK2, "KICK:CLTS:185:BMAGY.HOPR")
  field(LNK3, "KICK:CLTS:185:BLEM.HOPR")
  field(LNK4, "KICK:CLTS:185:BMAGX.LOPR PP")
  field(LNK5, "KICK:CLTS:185:BMAGY.LOPR PP")
  field(LNK6, "KICK:CLTS:185:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:CLTS:185:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:CLTS:185:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:CLTS:185:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV-c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:CLTS:185:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV-c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:CLTS:185:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:CLTS:185:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:CLTS:185:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:CLTS:185:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:CLTS:185:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:CLTS:185:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:CLTS:185:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:CLTS:185:EDES NPP MS")
  field(INPB, "KICK:CLTS:185:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:CLTS:180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "BEND:CLTS:180:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "BEND:CLTS:180:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "BEND:CLTS:180:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "BEND:CLTS:180:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "BEND:CLTS:180:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "BEND:CLTS:180:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "BEND:CLTS:180:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "BEND:CLTS:180:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "BEND:CLTS:180:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "BEND:CLTS:180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:CLTS:180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:CLTS:180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:CLTS:180:EDES.PROC PP")
    field(LNK2, "BEND:CLTS:180:EACT.PROC PP")
    field(LNK3, "BEND:CLTS:180:EERR.DISA PP")
    field(LNK4, "BEND:CLTS:180:ECON.PROC PP")
    field(LNK5, "BEND:CLTS:180:BMAGX.PROC PP")
    field(LNK6, "BEND:CLTS:180:BMAGY.PROC PP")
    field(LNK7, "BEND:CLTS:180:BLEM.PROC PP")
    field(LNK8, "BEND:CLTS:180:BMOD.PROC PP")
    field(LNK9, "BEND:CLTS:180:EDESSAVE.PROC PP")
    field(LNKA, "BEND:CLTS:180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:CLTS:180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:CLTS:180:BMAX")
  field(DOL2, "BEND:CLTS:180:BMAX")
  field(DOL3, "BEND:CLTS:180:BMAX")
  field(DOL4, "BEND:CLTS:180:BMIN")
  field(DOL5, "BEND:CLTS:180:BMIN")
  field(DOL6, "BEND:CLTS:180:BMIN")
  field(LNK1, "BEND:CLTS:180:BMAGX.HOPR")
  field(LNK2, "BEND:CLTS:180:BMAGY.HOPR")
  field(LNK3, "BEND:CLTS:180:BLEM.HOPR")
  field(LNK4, "BEND:CLTS:180:BMAGX.LOPR PP")
  field(LNK5, "BEND:CLTS:180:BMAGY.LOPR PP")
  field(LNK6, "BEND:CLTS:180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:CLTS:180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:CLTS:180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:CLTS:180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:CLTS:180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:CLTS:180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:CLTS:180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:CLTS:180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:CLTS:180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:CLTS:180:EDES NPP MS")
  field(INPB, "BEND:CLTS:180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:CLTS:280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "BEND:CLTS:280:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "BEND:CLTS:280:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "BEND:CLTS:280:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "BEND:CLTS:280:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "BEND:CLTS:280:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "BEND:CLTS:280:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "BEND:CLTS:280:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "BEND:CLTS:280:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "BEND:CLTS:280:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "BEND:CLTS:280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:CLTS:280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:CLTS:280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:CLTS:280:EDES.PROC PP")
    field(LNK2, "BEND:CLTS:280:EACT.PROC PP")
    field(LNK3, "BEND:CLTS:280:EERR.DISA PP")
    field(LNK4, "BEND:CLTS:280:ECON.PROC PP")
    field(LNK5, "BEND:CLTS:280:BMAGX.PROC PP")
    field(LNK6, "BEND:CLTS:280:BMAGY.PROC PP")
    field(LNK7, "BEND:CLTS:280:BLEM.PROC PP")
    field(LNK8, "BEND:CLTS:280:BMOD.PROC PP")
    field(LNK9, "BEND:CLTS:280:EDESSAVE.PROC PP")
    field(LNKA, "BEND:CLTS:280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:CLTS:280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:CLTS:280:BMAX")
  field(DOL2, "BEND:CLTS:280:BMAX")
  field(DOL3, "BEND:CLTS:280:BMAX")
  field(DOL4, "BEND:CLTS:280:BMIN")
  field(DOL5, "BEND:CLTS:280:BMIN")
  field(DOL6, "BEND:CLTS:280:BMIN")
  field(LNK1, "BEND:CLTS:280:BMAGX.HOPR")
  field(LNK2, "BEND:CLTS:280:BMAGY.HOPR")
  field(LNK3, "BEND:CLTS:280:BLEM.HOPR")
  field(LNK4, "BEND:CLTS:280:BMAGX.LOPR PP")
  field(LNK5, "BEND:CLTS:280:BMAGY.LOPR PP")
  field(LNK6, "BEND:CLTS:280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:CLTS:280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:CLTS:280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:CLTS:280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:CLTS:280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:CLTS:280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:CLTS:280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:CLTS:280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:CLTS:280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:CLTS:280:EDES NPP MS")
  field(INPB, "BEND:CLTS:280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:CLTS:505:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "BEND:CLTS:505:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "BEND:CLTS:505:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "BEND:CLTS:505:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "BEND:CLTS:505:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "BEND:CLTS:505:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "BEND:CLTS:505:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "BEND:CLTS:505:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "BEND:CLTS:505:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "BEND:CLTS:505:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "BEND:CLTS:505:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:CLTS:505:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:CLTS:505:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:CLTS:505:EDES.PROC PP")
    field(LNK2, "BEND:CLTS:505:EACT.PROC PP")
    field(LNK3, "BEND:CLTS:505:EERR.DISA PP")
    field(LNK4, "BEND:CLTS:505:ECON.PROC PP")
    field(LNK5, "BEND:CLTS:505:BMAGX.PROC PP")
    field(LNK6, "BEND:CLTS:505:BMAGY.PROC PP")
    field(LNK7, "BEND:CLTS:505:BLEM.PROC PP")
    field(LNK8, "BEND:CLTS:505:BMOD.PROC PP")
    field(LNK9, "BEND:CLTS:505:EDESSAVE.PROC PP")
    field(LNKA, "BEND:CLTS:505:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:CLTS:505:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:CLTS:505:BMAX")
  field(DOL2, "BEND:CLTS:505:BMAX")
  field(DOL3, "BEND:CLTS:505:BMAX")
  field(DOL4, "BEND:CLTS:505:BMIN")
  field(DOL5, "BEND:CLTS:505:BMIN")
  field(DOL6, "BEND:CLTS:505:BMIN")
  field(LNK1, "BEND:CLTS:505:BMAGX.HOPR")
  field(LNK2, "BEND:CLTS:505:BMAGY.HOPR")
  field(LNK3, "BEND:CLTS:505:BLEM.HOPR")
  field(LNK4, "BEND:CLTS:505:BMAGX.LOPR PP")
  field(LNK5, "BEND:CLTS:505:BMAGY.LOPR PP")
  field(LNK6, "BEND:CLTS:505:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:CLTS:505:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:CLTS:505:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:CLTS:505:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:CLTS:505:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:CLTS:505:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:505:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:505:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:CLTS:505:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:505:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:CLTS:505:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:CLTS:505:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:CLTS:505:EDES NPP MS")
  field(INPB, "BEND:CLTS:505:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:CLTS:765:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "BEND:CLTS:765:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "BEND:CLTS:765:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "BEND:CLTS:765:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "BEND:CLTS:765:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "BEND:CLTS:765:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "BEND:CLTS:765:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "BEND:CLTS:765:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "BEND:CLTS:765:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "BEND:CLTS:765:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "BEND:CLTS:765:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:CLTS:765:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:CLTS:765:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:CLTS:765:EDES.PROC PP")
    field(LNK2, "BEND:CLTS:765:EACT.PROC PP")
    field(LNK3, "BEND:CLTS:765:EERR.DISA PP")
    field(LNK4, "BEND:CLTS:765:ECON.PROC PP")
    field(LNK5, "BEND:CLTS:765:BMAGX.PROC PP")
    field(LNK6, "BEND:CLTS:765:BMAGY.PROC PP")
    field(LNK7, "BEND:CLTS:765:BLEM.PROC PP")
    field(LNK8, "BEND:CLTS:765:BMOD.PROC PP")
    field(LNK9, "BEND:CLTS:765:EDESSAVE.PROC PP")
    field(LNKA, "BEND:CLTS:765:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:CLTS:765:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:CLTS:765:BMAX")
  field(DOL2, "BEND:CLTS:765:BMAX")
  field(DOL3, "BEND:CLTS:765:BMAX")
  field(DOL4, "BEND:CLTS:765:BMIN")
  field(DOL5, "BEND:CLTS:765:BMIN")
  field(DOL6, "BEND:CLTS:765:BMIN")
  field(LNK1, "BEND:CLTS:765:BMAGX.HOPR")
  field(LNK2, "BEND:CLTS:765:BMAGY.HOPR")
  field(LNK3, "BEND:CLTS:765:BLEM.HOPR")
  field(LNK4, "BEND:CLTS:765:BMAGX.LOPR PP")
  field(LNK5, "BEND:CLTS:765:BMAGY.LOPR PP")
  field(LNK6, "BEND:CLTS:765:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:CLTS:765:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:CLTS:765:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:CLTS:765:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:CLTS:765:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:CLTS:765:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:765:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:765:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:CLTS:765:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:765:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:CLTS:765:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:CLTS:765:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:CLTS:765:EDES NPP MS")
  field(INPB, "BEND:CLTS:765:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:CLTS:280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "BTRM:CLTS:280:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "BTRM:CLTS:280:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:CLTS:280:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:CLTS:280:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "BTRM:CLTS:280:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "BTRM:CLTS:280:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "BTRM:CLTS:280:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:CLTS:280:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "BTRM:CLTS:280:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:CLTS:280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:CLTS:280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:CLTS:280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:CLTS:280:EDES.PROC PP")
    field(LNK2, "BTRM:CLTS:280:EACT.PROC PP")
    field(LNK3, "BTRM:CLTS:280:EERR.DISA PP")
    field(LNK4, "BTRM:CLTS:280:ECON.PROC PP")
    field(LNK5, "BTRM:CLTS:280:BMAGX.PROC PP")
    field(LNK6, "BTRM:CLTS:280:BMAGY.PROC PP")
    field(LNK7, "BTRM:CLTS:280:BLEM.PROC PP")
    field(LNK8, "BTRM:CLTS:280:BMOD.PROC PP")
    field(LNK9, "BTRM:CLTS:280:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:CLTS:280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:CLTS:280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:CLTS:280:BMAX")
  field(DOL2, "BTRM:CLTS:280:BMAX")
  field(DOL3, "BTRM:CLTS:280:BMAX")
  field(DOL4, "BTRM:CLTS:280:BMIN")
  field(DOL5, "BTRM:CLTS:280:BMIN")
  field(DOL6, "BTRM:CLTS:280:BMIN")
  field(LNK1, "BTRM:CLTS:280:BMAGX.HOPR")
  field(LNK2, "BTRM:CLTS:280:BMAGY.HOPR")
  field(LNK3, "BTRM:CLTS:280:BLEM.HOPR")
  field(LNK4, "BTRM:CLTS:280:BMAGX.LOPR PP")
  field(LNK5, "BTRM:CLTS:280:BMAGY.LOPR PP")
  field(LNK6, "BTRM:CLTS:280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:CLTS:280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:CLTS:280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:CLTS:280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:CLTS:280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:CLTS:280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:CLTS:280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:CLTS:280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:CLTS:280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:CLTS:280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:CLTS:280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:CLTS:280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:CLTS:280:EDES NPP MS")
  field(INPB, "BTRM:CLTS:280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:CLTS:765:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "BTRM:CLTS:765:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "BTRM:CLTS:765:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:CLTS:765:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:CLTS:765:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "BTRM:CLTS:765:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "BTRM:CLTS:765:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "BTRM:CLTS:765:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:CLTS:765:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "BTRM:CLTS:765:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:CLTS:765:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:CLTS:765:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:CLTS:765:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:CLTS:765:EDES.PROC PP")
    field(LNK2, "BTRM:CLTS:765:EACT.PROC PP")
    field(LNK3, "BTRM:CLTS:765:EERR.DISA PP")
    field(LNK4, "BTRM:CLTS:765:ECON.PROC PP")
    field(LNK5, "BTRM:CLTS:765:BMAGX.PROC PP")
    field(LNK6, "BTRM:CLTS:765:BMAGY.PROC PP")
    field(LNK7, "BTRM:CLTS:765:BLEM.PROC PP")
    field(LNK8, "BTRM:CLTS:765:BMOD.PROC PP")
    field(LNK9, "BTRM:CLTS:765:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:CLTS:765:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:CLTS:765:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:CLTS:765:BMAX")
  field(DOL2, "BTRM:CLTS:765:BMAX")
  field(DOL3, "BTRM:CLTS:765:BMAX")
  field(DOL4, "BTRM:CLTS:765:BMIN")
  field(DOL5, "BTRM:CLTS:765:BMIN")
  field(DOL6, "BTRM:CLTS:765:BMIN")
  field(LNK1, "BTRM:CLTS:765:BMAGX.HOPR")
  field(LNK2, "BTRM:CLTS:765:BMAGY.HOPR")
  field(LNK3, "BTRM:CLTS:765:BLEM.HOPR")
  field(LNK4, "BTRM:CLTS:765:BMAGX.LOPR PP")
  field(LNK5, "BTRM:CLTS:765:BMAGY.LOPR PP")
  field(LNK6, "BTRM:CLTS:765:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:CLTS:765:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:CLTS:765:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:CLTS:765:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:CLTS:765:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:CLTS:765:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:CLTS:765:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:CLTS:765:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:CLTS:765:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:CLTS:765:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:CLTS:765:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:CLTS:765:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:CLTS:765:EDES NPP MS")
  field(INPB, "BTRM:CLTS:765:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:CLTS:420:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "QUAD:CLTS:420:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "QUAD:CLTS:420:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:CLTS:420:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:CLTS:420:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "QUAD:CLTS:420:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "QUAD:CLTS:420:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "QUAD:CLTS:420:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:CLTS:420:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "QUAD:CLTS:420:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:CLTS:420:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:CLTS:420:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:CLTS:420:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:CLTS:420:EDES.PROC PP")
    field(LNK2, "QUAD:CLTS:420:EACT.PROC PP")
    field(LNK3, "QUAD:CLTS:420:EERR.DISA PP")
    field(LNK4, "QUAD:CLTS:420:ECON.PROC PP")
    field(LNK5, "QUAD:CLTS:420:BMAGX.PROC PP")
    field(LNK6, "QUAD:CLTS:420:BMAGY.PROC PP")
    field(LNK7, "QUAD:CLTS:420:BLEM.PROC PP")
    field(LNK8, "QUAD:CLTS:420:BMOD.PROC PP")
    field(LNK9, "QUAD:CLTS:420:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:CLTS:420:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:CLTS:420:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:CLTS:420:BMAX")
  field(DOL2, "QUAD:CLTS:420:BMAX")
  field(DOL3, "QUAD:CLTS:420:BMAX")
  field(DOL4, "QUAD:CLTS:420:BMIN")
  field(DOL5, "QUAD:CLTS:420:BMIN")
  field(DOL6, "QUAD:CLTS:420:BMIN")
  field(LNK1, "QUAD:CLTS:420:BMAGX.HOPR")
  field(LNK2, "QUAD:CLTS:420:BMAGY.HOPR")
  field(LNK3, "QUAD:CLTS:420:BLEM.HOPR")
  field(LNK4, "QUAD:CLTS:420:BMAGX.LOPR PP")
  field(LNK5, "QUAD:CLTS:420:BMAGY.LOPR PP")
  field(LNK6, "QUAD:CLTS:420:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:420:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:420:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:CLTS:420:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:CLTS:420:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:CLTS:420:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:420:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:420:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTS:420:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:420:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTS:420:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:CLTS:420:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:CLTS:420:EDES NPP MS")
  field(INPB, "QUAD:CLTS:420:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:CLTS:450:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "QUAD:CLTS:450:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "QUAD:CLTS:450:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:CLTS:450:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:CLTS:450:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "QUAD:CLTS:450:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "QUAD:CLTS:450:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "QUAD:CLTS:450:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:CLTS:450:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "QUAD:CLTS:450:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:CLTS:450:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:CLTS:450:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:CLTS:450:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:CLTS:450:EDES.PROC PP")
    field(LNK2, "QUAD:CLTS:450:EACT.PROC PP")
    field(LNK3, "QUAD:CLTS:450:EERR.DISA PP")
    field(LNK4, "QUAD:CLTS:450:ECON.PROC PP")
    field(LNK5, "QUAD:CLTS:450:BMAGX.PROC PP")
    field(LNK6, "QUAD:CLTS:450:BMAGY.PROC PP")
    field(LNK7, "QUAD:CLTS:450:BLEM.PROC PP")
    field(LNK8, "QUAD:CLTS:450:BMOD.PROC PP")
    field(LNK9, "QUAD:CLTS:450:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:CLTS:450:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:CLTS:450:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:CLTS:450:BMAX")
  field(DOL2, "QUAD:CLTS:450:BMAX")
  field(DOL3, "QUAD:CLTS:450:BMAX")
  field(DOL4, "QUAD:CLTS:450:BMIN")
  field(DOL5, "QUAD:CLTS:450:BMIN")
  field(DOL6, "QUAD:CLTS:450:BMIN")
  field(LNK1, "QUAD:CLTS:450:BMAGX.HOPR")
  field(LNK2, "QUAD:CLTS:450:BMAGY.HOPR")
  field(LNK3, "QUAD:CLTS:450:BLEM.HOPR")
  field(LNK4, "QUAD:CLTS:450:BMAGX.LOPR PP")
  field(LNK5, "QUAD:CLTS:450:BMAGY.LOPR PP")
  field(LNK6, "QUAD:CLTS:450:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:450:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:450:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:CLTS:450:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:CLTS:450:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:CLTS:450:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:450:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:450:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTS:450:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:450:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTS:450:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:CLTS:450:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:CLTS:450:EDES NPP MS")
  field(INPB, "QUAD:CLTS:450:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:CLTS:470:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "QUAD:CLTS:470:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "QUAD:CLTS:470:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:CLTS:470:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:CLTS:470:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "QUAD:CLTS:470:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "QUAD:CLTS:470:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "QUAD:CLTS:470:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:CLTS:470:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "QUAD:CLTS:470:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:CLTS:470:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:CLTS:470:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:CLTS:470:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:CLTS:470:EDES.PROC PP")
    field(LNK2, "QUAD:CLTS:470:EACT.PROC PP")
    field(LNK3, "QUAD:CLTS:470:EERR.DISA PP")
    field(LNK4, "QUAD:CLTS:470:ECON.PROC PP")
    field(LNK5, "QUAD:CLTS:470:BMAGX.PROC PP")
    field(LNK6, "QUAD:CLTS:470:BMAGY.PROC PP")
    field(LNK7, "QUAD:CLTS:470:BLEM.PROC PP")
    field(LNK8, "QUAD:CLTS:470:BMOD.PROC PP")
    field(LNK9, "QUAD:CLTS:470:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:CLTS:470:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:CLTS:470:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:CLTS:470:BMAX")
  field(DOL2, "QUAD:CLTS:470:BMAX")
  field(DOL3, "QUAD:CLTS:470:BMAX")
  field(DOL4, "QUAD:CLTS:470:BMIN")
  field(DOL5, "QUAD:CLTS:470:BMIN")
  field(DOL6, "QUAD:CLTS:470:BMIN")
  field(LNK1, "QUAD:CLTS:470:BMAGX.HOPR")
  field(LNK2, "QUAD:CLTS:470:BMAGY.HOPR")
  field(LNK3, "QUAD:CLTS:470:BLEM.HOPR")
  field(LNK4, "QUAD:CLTS:470:BMAGX.LOPR PP")
  field(LNK5, "QUAD:CLTS:470:BMAGY.LOPR PP")
  field(LNK6, "QUAD:CLTS:470:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:470:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:470:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:CLTS:470:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:CLTS:470:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:CLTS:470:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:470:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:470:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTS:470:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:470:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTS:470:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:CLTS:470:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:CLTS:470:EDES NPP MS")
  field(INPB, "QUAD:CLTS:470:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:CLTS:500:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "QUAD:CLTS:500:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "QUAD:CLTS:500:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:CLTS:500:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:CLTS:500:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "QUAD:CLTS:500:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "QUAD:CLTS:500:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "QUAD:CLTS:500:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:CLTS:500:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "QUAD:CLTS:500:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:CLTS:500:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:CLTS:500:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:CLTS:500:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:CLTS:500:EDES.PROC PP")
    field(LNK2, "QUAD:CLTS:500:EACT.PROC PP")
    field(LNK3, "QUAD:CLTS:500:EERR.DISA PP")
    field(LNK4, "QUAD:CLTS:500:ECON.PROC PP")
    field(LNK5, "QUAD:CLTS:500:BMAGX.PROC PP")
    field(LNK6, "QUAD:CLTS:500:BMAGY.PROC PP")
    field(LNK7, "QUAD:CLTS:500:BLEM.PROC PP")
    field(LNK8, "QUAD:CLTS:500:BMOD.PROC PP")
    field(LNK9, "QUAD:CLTS:500:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:CLTS:500:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:CLTS:500:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:CLTS:500:BMAX")
  field(DOL2, "QUAD:CLTS:500:BMAX")
  field(DOL3, "QUAD:CLTS:500:BMAX")
  field(DOL4, "QUAD:CLTS:500:BMIN")
  field(DOL5, "QUAD:CLTS:500:BMIN")
  field(DOL6, "QUAD:CLTS:500:BMIN")
  field(LNK1, "QUAD:CLTS:500:BMAGX.HOPR")
  field(LNK2, "QUAD:CLTS:500:BMAGY.HOPR")
  field(LNK3, "QUAD:CLTS:500:BLEM.HOPR")
  field(LNK4, "QUAD:CLTS:500:BMAGX.LOPR PP")
  field(LNK5, "QUAD:CLTS:500:BMAGY.LOPR PP")
  field(LNK6, "QUAD:CLTS:500:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:500:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:500:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:CLTS:500:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:CLTS:500:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:CLTS:500:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:500:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:500:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTS:500:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:500:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTS:500:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:CLTS:500:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:CLTS:500:EDES NPP MS")
  field(INPB, "QUAD:CLTS:500:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:CLTS:510:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "QUAD:CLTS:510:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "QUAD:CLTS:510:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:CLTS:510:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:CLTS:510:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "QUAD:CLTS:510:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "QUAD:CLTS:510:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "QUAD:CLTS:510:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:CLTS:510:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "QUAD:CLTS:510:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:CLTS:510:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:CLTS:510:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:CLTS:510:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:CLTS:510:EDES.PROC PP")
    field(LNK2, "QUAD:CLTS:510:EACT.PROC PP")
    field(LNK3, "QUAD:CLTS:510:EERR.DISA PP")
    field(LNK4, "QUAD:CLTS:510:ECON.PROC PP")
    field(LNK5, "QUAD:CLTS:510:BMAGX.PROC PP")
    field(LNK6, "QUAD:CLTS:510:BMAGY.PROC PP")
    field(LNK7, "QUAD:CLTS:510:BLEM.PROC PP")
    field(LNK8, "QUAD:CLTS:510:BMOD.PROC PP")
    field(LNK9, "QUAD:CLTS:510:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:CLTS:510:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:CLTS:510:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:CLTS:510:BMAX")
  field(DOL2, "QUAD:CLTS:510:BMAX")
  field(DOL3, "QUAD:CLTS:510:BMAX")
  field(DOL4, "QUAD:CLTS:510:BMIN")
  field(DOL5, "QUAD:CLTS:510:BMIN")
  field(DOL6, "QUAD:CLTS:510:BMIN")
  field(LNK1, "QUAD:CLTS:510:BMAGX.HOPR")
  field(LNK2, "QUAD:CLTS:510:BMAGY.HOPR")
  field(LNK3, "QUAD:CLTS:510:BLEM.HOPR")
  field(LNK4, "QUAD:CLTS:510:BMAGX.LOPR PP")
  field(LNK5, "QUAD:CLTS:510:BMAGY.LOPR PP")
  field(LNK6, "QUAD:CLTS:510:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:510:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:510:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:CLTS:510:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:CLTS:510:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:CLTS:510:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:510:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:510:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTS:510:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:510:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTS:510:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:CLTS:510:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:CLTS:510:EDES NPP MS")
  field(INPB, "QUAD:CLTS:510:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:CLTS:590:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "QUAD:CLTS:590:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "QUAD:CLTS:590:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:CLTS:590:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:CLTS:590:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "QUAD:CLTS:590:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "QUAD:CLTS:590:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "QUAD:CLTS:590:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:CLTS:590:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "QUAD:CLTS:590:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:CLTS:590:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:CLTS:590:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:CLTS:590:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:CLTS:590:EDES.PROC PP")
    field(LNK2, "QUAD:CLTS:590:EACT.PROC PP")
    field(LNK3, "QUAD:CLTS:590:EERR.DISA PP")
    field(LNK4, "QUAD:CLTS:590:ECON.PROC PP")
    field(LNK5, "QUAD:CLTS:590:BMAGX.PROC PP")
    field(LNK6, "QUAD:CLTS:590:BMAGY.PROC PP")
    field(LNK7, "QUAD:CLTS:590:BLEM.PROC PP")
    field(LNK8, "QUAD:CLTS:590:BMOD.PROC PP")
    field(LNK9, "QUAD:CLTS:590:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:CLTS:590:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:CLTS:590:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:CLTS:590:BMAX")
  field(DOL2, "QUAD:CLTS:590:BMAX")
  field(DOL3, "QUAD:CLTS:590:BMAX")
  field(DOL4, "QUAD:CLTS:590:BMIN")
  field(DOL5, "QUAD:CLTS:590:BMIN")
  field(DOL6, "QUAD:CLTS:590:BMIN")
  field(LNK1, "QUAD:CLTS:590:BMAGX.HOPR")
  field(LNK2, "QUAD:CLTS:590:BMAGY.HOPR")
  field(LNK3, "QUAD:CLTS:590:BLEM.HOPR")
  field(LNK4, "QUAD:CLTS:590:BMAGX.LOPR PP")
  field(LNK5, "QUAD:CLTS:590:BMAGY.LOPR PP")
  field(LNK6, "QUAD:CLTS:590:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:590:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:590:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:CLTS:590:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:CLTS:590:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:CLTS:590:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:590:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:590:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTS:590:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:590:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTS:590:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:CLTS:590:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:CLTS:590:EDES NPP MS")
  field(INPB, "QUAD:CLTS:590:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:CLTS:620:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "QUAD:CLTS:620:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "QUAD:CLTS:620:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:CLTS:620:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:CLTS:620:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "QUAD:CLTS:620:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "QUAD:CLTS:620:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "QUAD:CLTS:620:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:CLTS:620:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "QUAD:CLTS:620:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:CLTS:620:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:CLTS:620:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:CLTS:620:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:CLTS:620:EDES.PROC PP")
    field(LNK2, "QUAD:CLTS:620:EACT.PROC PP")
    field(LNK3, "QUAD:CLTS:620:EERR.DISA PP")
    field(LNK4, "QUAD:CLTS:620:ECON.PROC PP")
    field(LNK5, "QUAD:CLTS:620:BMAGX.PROC PP")
    field(LNK6, "QUAD:CLTS:620:BMAGY.PROC PP")
    field(LNK7, "QUAD:CLTS:620:BLEM.PROC PP")
    field(LNK8, "QUAD:CLTS:620:BMOD.PROC PP")
    field(LNK9, "QUAD:CLTS:620:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:CLTS:620:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:CLTS:620:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:CLTS:620:BMAX")
  field(DOL2, "QUAD:CLTS:620:BMAX")
  field(DOL3, "QUAD:CLTS:620:BMAX")
  field(DOL4, "QUAD:CLTS:620:BMIN")
  field(DOL5, "QUAD:CLTS:620:BMIN")
  field(DOL6, "QUAD:CLTS:620:BMIN")
  field(LNK1, "QUAD:CLTS:620:BMAGX.HOPR")
  field(LNK2, "QUAD:CLTS:620:BMAGY.HOPR")
  field(LNK3, "QUAD:CLTS:620:BLEM.HOPR")
  field(LNK4, "QUAD:CLTS:620:BMAGX.LOPR PP")
  field(LNK5, "QUAD:CLTS:620:BMAGY.LOPR PP")
  field(LNK6, "QUAD:CLTS:620:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:620:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:620:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:CLTS:620:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:CLTS:620:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:CLTS:620:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:620:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:620:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTS:620:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:620:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:CLTS:620:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:CLTS:620:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:CLTS:620:EDES NPP MS")
  field(INPB, "QUAD:CLTS:620:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:CLTS:426:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "XCOR:CLTS:426:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "XCOR:CLTS:426:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:CLTS:426:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:CLTS:426:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "XCOR:CLTS:426:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "XCOR:CLTS:426:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "XCOR:CLTS:426:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:CLTS:426:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "XCOR:CLTS:426:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:CLTS:426:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:CLTS:426:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:CLTS:426:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:CLTS:426:EDES.PROC PP")
    field(LNK2, "XCOR:CLTS:426:EACT.PROC PP")
    field(LNK3, "XCOR:CLTS:426:EERR.DISA PP")
    field(LNK4, "XCOR:CLTS:426:ECON.PROC PP")
    field(LNK5, "XCOR:CLTS:426:BMAGX.PROC PP")
    field(LNK6, "XCOR:CLTS:426:BMAGY.PROC PP")
    field(LNK7, "XCOR:CLTS:426:BLEM.PROC PP")
    field(LNK8, "XCOR:CLTS:426:BMOD.PROC PP")
    field(LNK9, "XCOR:CLTS:426:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:CLTS:426:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:CLTS:426:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:CLTS:426:BMAX")
  field(DOL2, "XCOR:CLTS:426:BMAX")
  field(DOL3, "XCOR:CLTS:426:BMAX")
  field(DOL4, "XCOR:CLTS:426:BMIN")
  field(DOL5, "XCOR:CLTS:426:BMIN")
  field(DOL6, "XCOR:CLTS:426:BMIN")
  field(LNK1, "XCOR:CLTS:426:BMAGX.HOPR")
  field(LNK2, "XCOR:CLTS:426:BMAGY.HOPR")
  field(LNK3, "XCOR:CLTS:426:BLEM.HOPR")
  field(LNK4, "XCOR:CLTS:426:BMAGX.LOPR PP")
  field(LNK5, "XCOR:CLTS:426:BMAGY.LOPR PP")
  field(LNK6, "XCOR:CLTS:426:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:CLTS:426:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:CLTS:426:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:CLTS:426:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:CLTS:426:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:CLTS:426:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:CLTS:426:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:CLTS:426:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:CLTS:426:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:CLTS:426:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:CLTS:426:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:CLTS:426:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:CLTS:426:EDES NPP MS")
  field(INPB, "XCOR:CLTS:426:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:CLTS:504:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "XCOR:CLTS:504:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "XCOR:CLTS:504:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:CLTS:504:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:CLTS:504:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "XCOR:CLTS:504:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "XCOR:CLTS:504:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "XCOR:CLTS:504:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:CLTS:504:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "XCOR:CLTS:504:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:CLTS:504:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:CLTS:504:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:CLTS:504:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:CLTS:504:EDES.PROC PP")
    field(LNK2, "XCOR:CLTS:504:EACT.PROC PP")
    field(LNK3, "XCOR:CLTS:504:EERR.DISA PP")
    field(LNK4, "XCOR:CLTS:504:ECON.PROC PP")
    field(LNK5, "XCOR:CLTS:504:BMAGX.PROC PP")
    field(LNK6, "XCOR:CLTS:504:BMAGY.PROC PP")
    field(LNK7, "XCOR:CLTS:504:BLEM.PROC PP")
    field(LNK8, "XCOR:CLTS:504:BMOD.PROC PP")
    field(LNK9, "XCOR:CLTS:504:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:CLTS:504:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:CLTS:504:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:CLTS:504:BMAX")
  field(DOL2, "XCOR:CLTS:504:BMAX")
  field(DOL3, "XCOR:CLTS:504:BMAX")
  field(DOL4, "XCOR:CLTS:504:BMIN")
  field(DOL5, "XCOR:CLTS:504:BMIN")
  field(DOL6, "XCOR:CLTS:504:BMIN")
  field(LNK1, "XCOR:CLTS:504:BMAGX.HOPR")
  field(LNK2, "XCOR:CLTS:504:BMAGY.HOPR")
  field(LNK3, "XCOR:CLTS:504:BLEM.HOPR")
  field(LNK4, "XCOR:CLTS:504:BMAGX.LOPR PP")
  field(LNK5, "XCOR:CLTS:504:BMAGY.LOPR PP")
  field(LNK6, "XCOR:CLTS:504:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:CLTS:504:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:CLTS:504:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:CLTS:504:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:CLTS:504:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:CLTS:504:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:CLTS:504:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:CLTS:504:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:CLTS:504:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:CLTS:504:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:CLTS:504:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:CLTS:504:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:CLTS:504:EDES NPP MS")
  field(INPB, "XCOR:CLTS:504:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:CLTS:542:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "XCOR:CLTS:542:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "XCOR:CLTS:542:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:CLTS:542:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:CLTS:542:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "XCOR:CLTS:542:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "XCOR:CLTS:542:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "XCOR:CLTS:542:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:CLTS:542:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "XCOR:CLTS:542:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:CLTS:542:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:CLTS:542:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:CLTS:542:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:CLTS:542:EDES.PROC PP")
    field(LNK2, "XCOR:CLTS:542:EACT.PROC PP")
    field(LNK3, "XCOR:CLTS:542:EERR.DISA PP")
    field(LNK4, "XCOR:CLTS:542:ECON.PROC PP")
    field(LNK5, "XCOR:CLTS:542:BMAGX.PROC PP")
    field(LNK6, "XCOR:CLTS:542:BMAGY.PROC PP")
    field(LNK7, "XCOR:CLTS:542:BLEM.PROC PP")
    field(LNK8, "XCOR:CLTS:542:BMOD.PROC PP")
    field(LNK9, "XCOR:CLTS:542:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:CLTS:542:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:CLTS:542:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:CLTS:542:BMAX")
  field(DOL2, "XCOR:CLTS:542:BMAX")
  field(DOL3, "XCOR:CLTS:542:BMAX")
  field(DOL4, "XCOR:CLTS:542:BMIN")
  field(DOL5, "XCOR:CLTS:542:BMIN")
  field(DOL6, "XCOR:CLTS:542:BMIN")
  field(LNK1, "XCOR:CLTS:542:BMAGX.HOPR")
  field(LNK2, "XCOR:CLTS:542:BMAGY.HOPR")
  field(LNK3, "XCOR:CLTS:542:BLEM.HOPR")
  field(LNK4, "XCOR:CLTS:542:BMAGX.LOPR PP")
  field(LNK5, "XCOR:CLTS:542:BMAGY.LOPR PP")
  field(LNK6, "XCOR:CLTS:542:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:CLTS:542:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:CLTS:542:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:CLTS:542:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:CLTS:542:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:CLTS:542:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:CLTS:542:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:CLTS:542:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:CLTS:542:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:CLTS:542:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:CLTS:542:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:CLTS:542:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:CLTS:542:EDES NPP MS")
  field(INPB, "XCOR:CLTS:542:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:CLTS:614:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "XCOR:CLTS:614:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "XCOR:CLTS:614:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:CLTS:614:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:CLTS:614:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "XCOR:CLTS:614:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "XCOR:CLTS:614:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "XCOR:CLTS:614:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:CLTS:614:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "XCOR:CLTS:614:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:CLTS:614:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:CLTS:614:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:CLTS:614:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:CLTS:614:EDES.PROC PP")
    field(LNK2, "XCOR:CLTS:614:EACT.PROC PP")
    field(LNK3, "XCOR:CLTS:614:EERR.DISA PP")
    field(LNK4, "XCOR:CLTS:614:ECON.PROC PP")
    field(LNK5, "XCOR:CLTS:614:BMAGX.PROC PP")
    field(LNK6, "XCOR:CLTS:614:BMAGY.PROC PP")
    field(LNK7, "XCOR:CLTS:614:BLEM.PROC PP")
    field(LNK8, "XCOR:CLTS:614:BMOD.PROC PP")
    field(LNK9, "XCOR:CLTS:614:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:CLTS:614:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:CLTS:614:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:CLTS:614:BMAX")
  field(DOL2, "XCOR:CLTS:614:BMAX")
  field(DOL3, "XCOR:CLTS:614:BMAX")
  field(DOL4, "XCOR:CLTS:614:BMIN")
  field(DOL5, "XCOR:CLTS:614:BMIN")
  field(DOL6, "XCOR:CLTS:614:BMIN")
  field(LNK1, "XCOR:CLTS:614:BMAGX.HOPR")
  field(LNK2, "XCOR:CLTS:614:BMAGY.HOPR")
  field(LNK3, "XCOR:CLTS:614:BLEM.HOPR")
  field(LNK4, "XCOR:CLTS:614:BMAGX.LOPR PP")
  field(LNK5, "XCOR:CLTS:614:BMAGY.LOPR PP")
  field(LNK6, "XCOR:CLTS:614:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:CLTS:614:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:CLTS:614:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:CLTS:614:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:CLTS:614:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:CLTS:614:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:CLTS:614:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:CLTS:614:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:CLTS:614:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:CLTS:614:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:CLTS:614:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:CLTS:614:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:CLTS:614:EDES NPP MS")
  field(INPB, "XCOR:CLTS:614:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:CLTS:453:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "YCOR:CLTS:453:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "YCOR:CLTS:453:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:CLTS:453:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:CLTS:453:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "YCOR:CLTS:453:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "YCOR:CLTS:453:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "YCOR:CLTS:453:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:CLTS:453:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "YCOR:CLTS:453:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:CLTS:453:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:CLTS:453:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:CLTS:453:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:CLTS:453:EDES.PROC PP")
    field(LNK2, "YCOR:CLTS:453:EACT.PROC PP")
    field(LNK3, "YCOR:CLTS:453:EERR.DISA PP")
    field(LNK4, "YCOR:CLTS:453:ECON.PROC PP")
    field(LNK5, "YCOR:CLTS:453:BMAGX.PROC PP")
    field(LNK6, "YCOR:CLTS:453:BMAGY.PROC PP")
    field(LNK7, "YCOR:CLTS:453:BLEM.PROC PP")
    field(LNK8, "YCOR:CLTS:453:BMOD.PROC PP")
    field(LNK9, "YCOR:CLTS:453:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:CLTS:453:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:CLTS:453:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:CLTS:453:BMAX")
  field(DOL2, "YCOR:CLTS:453:BMAX")
  field(DOL3, "YCOR:CLTS:453:BMAX")
  field(DOL4, "YCOR:CLTS:453:BMIN")
  field(DOL5, "YCOR:CLTS:453:BMIN")
  field(DOL6, "YCOR:CLTS:453:BMIN")
  field(LNK1, "YCOR:CLTS:453:BMAGX.HOPR")
  field(LNK2, "YCOR:CLTS:453:BMAGY.HOPR")
  field(LNK3, "YCOR:CLTS:453:BLEM.HOPR")
  field(LNK4, "YCOR:CLTS:453:BMAGX.LOPR PP")
  field(LNK5, "YCOR:CLTS:453:BMAGY.LOPR PP")
  field(LNK6, "YCOR:CLTS:453:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:CLTS:453:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:CLTS:453:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:CLTS:453:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:CLTS:453:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:CLTS:453:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTS:453:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTS:453:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:CLTS:453:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTS:453:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:CLTS:453:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:CLTS:453:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:CLTS:453:EDES NPP MS")
  field(INPB, "YCOR:CLTS:453:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:CLTS:471:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "YCOR:CLTS:471:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "YCOR:CLTS:471:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:CLTS:471:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:CLTS:471:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "YCOR:CLTS:471:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "YCOR:CLTS:471:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "YCOR:CLTS:471:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:CLTS:471:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "YCOR:CLTS:471:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:CLTS:471:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:CLTS:471:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:CLTS:471:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:CLTS:471:EDES.PROC PP")
    field(LNK2, "YCOR:CLTS:471:EACT.PROC PP")
    field(LNK3, "YCOR:CLTS:471:EERR.DISA PP")
    field(LNK4, "YCOR:CLTS:471:ECON.PROC PP")
    field(LNK5, "YCOR:CLTS:471:BMAGX.PROC PP")
    field(LNK6, "YCOR:CLTS:471:BMAGY.PROC PP")
    field(LNK7, "YCOR:CLTS:471:BLEM.PROC PP")
    field(LNK8, "YCOR:CLTS:471:BMOD.PROC PP")
    field(LNK9, "YCOR:CLTS:471:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:CLTS:471:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:CLTS:471:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:CLTS:471:BMAX")
  field(DOL2, "YCOR:CLTS:471:BMAX")
  field(DOL3, "YCOR:CLTS:471:BMAX")
  field(DOL4, "YCOR:CLTS:471:BMIN")
  field(DOL5, "YCOR:CLTS:471:BMIN")
  field(DOL6, "YCOR:CLTS:471:BMIN")
  field(LNK1, "YCOR:CLTS:471:BMAGX.HOPR")
  field(LNK2, "YCOR:CLTS:471:BMAGY.HOPR")
  field(LNK3, "YCOR:CLTS:471:BLEM.HOPR")
  field(LNK4, "YCOR:CLTS:471:BMAGX.LOPR PP")
  field(LNK5, "YCOR:CLTS:471:BMAGY.LOPR PP")
  field(LNK6, "YCOR:CLTS:471:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:CLTS:471:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:CLTS:471:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:CLTS:471:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:CLTS:471:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:CLTS:471:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTS:471:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTS:471:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:CLTS:471:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTS:471:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:CLTS:471:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:CLTS:471:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:CLTS:471:EDES NPP MS")
  field(INPB, "YCOR:CLTS:471:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:CLTS:533:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "YCOR:CLTS:533:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "YCOR:CLTS:533:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:CLTS:533:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:CLTS:533:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "YCOR:CLTS:533:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "YCOR:CLTS:533:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "YCOR:CLTS:533:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:CLTS:533:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "YCOR:CLTS:533:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:CLTS:533:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:CLTS:533:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:CLTS:533:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:CLTS:533:EDES.PROC PP")
    field(LNK2, "YCOR:CLTS:533:EACT.PROC PP")
    field(LNK3, "YCOR:CLTS:533:EERR.DISA PP")
    field(LNK4, "YCOR:CLTS:533:ECON.PROC PP")
    field(LNK5, "YCOR:CLTS:533:BMAGX.PROC PP")
    field(LNK6, "YCOR:CLTS:533:BMAGY.PROC PP")
    field(LNK7, "YCOR:CLTS:533:BLEM.PROC PP")
    field(LNK8, "YCOR:CLTS:533:BMOD.PROC PP")
    field(LNK9, "YCOR:CLTS:533:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:CLTS:533:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:CLTS:533:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:CLTS:533:BMAX")
  field(DOL2, "YCOR:CLTS:533:BMAX")
  field(DOL3, "YCOR:CLTS:533:BMAX")
  field(DOL4, "YCOR:CLTS:533:BMIN")
  field(DOL5, "YCOR:CLTS:533:BMIN")
  field(DOL6, "YCOR:CLTS:533:BMIN")
  field(LNK1, "YCOR:CLTS:533:BMAGX.HOPR")
  field(LNK2, "YCOR:CLTS:533:BMAGY.HOPR")
  field(LNK3, "YCOR:CLTS:533:BLEM.HOPR")
  field(LNK4, "YCOR:CLTS:533:BMAGX.LOPR PP")
  field(LNK5, "YCOR:CLTS:533:BMAGY.LOPR PP")
  field(LNK6, "YCOR:CLTS:533:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:CLTS:533:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:CLTS:533:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:CLTS:533:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:CLTS:533:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:CLTS:533:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTS:533:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTS:533:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:CLTS:533:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTS:533:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:CLTS:533:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:CLTS:533:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:CLTS:533:EDES NPP MS")
  field(INPB, "YCOR:CLTS:533:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:CLTS:573:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "YCOR:CLTS:573:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "YCOR:CLTS:573:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:CLTS:573:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:CLTS:573:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "YCOR:CLTS:573:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "YCOR:CLTS:573:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "YCOR:CLTS:573:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:CLTS:573:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "YCOR:CLTS:573:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:CLTS:573:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:CLTS:573:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:CLTS:573:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:CLTS:573:EDES.PROC PP")
    field(LNK2, "YCOR:CLTS:573:EACT.PROC PP")
    field(LNK3, "YCOR:CLTS:573:EERR.DISA PP")
    field(LNK4, "YCOR:CLTS:573:ECON.PROC PP")
    field(LNK5, "YCOR:CLTS:573:BMAGX.PROC PP")
    field(LNK6, "YCOR:CLTS:573:BMAGY.PROC PP")
    field(LNK7, "YCOR:CLTS:573:BLEM.PROC PP")
    field(LNK8, "YCOR:CLTS:573:BMOD.PROC PP")
    field(LNK9, "YCOR:CLTS:573:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:CLTS:573:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:CLTS:573:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:CLTS:573:BMAX")
  field(DOL2, "YCOR:CLTS:573:BMAX")
  field(DOL3, "YCOR:CLTS:573:BMAX")
  field(DOL4, "YCOR:CLTS:573:BMIN")
  field(DOL5, "YCOR:CLTS:573:BMIN")
  field(DOL6, "YCOR:CLTS:573:BMIN")
  field(LNK1, "YCOR:CLTS:573:BMAGX.HOPR")
  field(LNK2, "YCOR:CLTS:573:BMAGY.HOPR")
  field(LNK3, "YCOR:CLTS:573:BLEM.HOPR")
  field(LNK4, "YCOR:CLTS:573:BMAGX.LOPR PP")
  field(LNK5, "YCOR:CLTS:573:BMAGY.LOPR PP")
  field(LNK6, "YCOR:CLTS:573:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:CLTS:573:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:CLTS:573:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:CLTS:573:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:CLTS:573:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:CLTS:573:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTS:573:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTS:573:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:CLTS:573:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTS:573:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:CLTS:573:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:CLTS:573:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:CLTS:573:EDES NPP MS")
  field(INPB, "YCOR:CLTS:573:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:CLTS:597:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "YCOR:CLTS:597:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "YCOR:CLTS:597:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:CLTS:597:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:CLTS:597:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "YCOR:CLTS:597:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "YCOR:CLTS:597:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "YCOR:CLTS:597:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:CLTS:597:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "YCOR:CLTS:597:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:CLTS:597:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:CLTS:597:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:CLTS:597:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:CLTS:597:EDES.PROC PP")
    field(LNK2, "YCOR:CLTS:597:EACT.PROC PP")
    field(LNK3, "YCOR:CLTS:597:EERR.DISA PP")
    field(LNK4, "YCOR:CLTS:597:ECON.PROC PP")
    field(LNK5, "YCOR:CLTS:597:BMAGX.PROC PP")
    field(LNK6, "YCOR:CLTS:597:BMAGY.PROC PP")
    field(LNK7, "YCOR:CLTS:597:BLEM.PROC PP")
    field(LNK8, "YCOR:CLTS:597:BMOD.PROC PP")
    field(LNK9, "YCOR:CLTS:597:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:CLTS:597:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:CLTS:597:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:CLTS:597:BMAX")
  field(DOL2, "YCOR:CLTS:597:BMAX")
  field(DOL3, "YCOR:CLTS:597:BMAX")
  field(DOL4, "YCOR:CLTS:597:BMIN")
  field(DOL5, "YCOR:CLTS:597:BMIN")
  field(DOL6, "YCOR:CLTS:597:BMIN")
  field(LNK1, "YCOR:CLTS:597:BMAGX.HOPR")
  field(LNK2, "YCOR:CLTS:597:BMAGY.HOPR")
  field(LNK3, "YCOR:CLTS:597:BLEM.HOPR")
  field(LNK4, "YCOR:CLTS:597:BMAGX.LOPR PP")
  field(LNK5, "YCOR:CLTS:597:BMAGY.LOPR PP")
  field(LNK6, "YCOR:CLTS:597:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:CLTS:597:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:CLTS:597:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:CLTS:597:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:CLTS:597:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:CLTS:597:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTS:597:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTS:597:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:CLTS:597:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:CLTS:597:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:CLTS:597:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:CLTS:597:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:CLTS:597:EDES NPP MS")
  field(INPB, "YCOR:CLTS:597:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:CLTS:190:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "BEND:CLTS:190:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "BEND:CLTS:190:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "BEND:CLTS:190:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "BEND:CLTS:190:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "BEND:CLTS:190:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "BEND:CLTS:190:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "BEND:CLTS:190:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "BEND:CLTS:190:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "BEND:CLTS:190:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "BEND:CLTS:190:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:CLTS:190:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:CLTS:190:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:CLTS:190:EDES.PROC PP")
    field(LNK2, "BEND:CLTS:190:EACT.PROC PP")
    field(LNK3, "BEND:CLTS:190:EERR.DISA PP")
    field(LNK4, "BEND:CLTS:190:ECON.PROC PP")
    field(LNK5, "BEND:CLTS:190:BMAGX.PROC PP")
    field(LNK6, "BEND:CLTS:190:BMAGY.PROC PP")
    field(LNK7, "BEND:CLTS:190:BLEM.PROC PP")
    field(LNK8, "BEND:CLTS:190:BMOD.PROC PP")
    field(LNK9, "BEND:CLTS:190:EDESSAVE.PROC PP")
    field(LNKA, "BEND:CLTS:190:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:CLTS:190:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:CLTS:190:BMAX")
  field(DOL2, "BEND:CLTS:190:BMAX")
  field(DOL3, "BEND:CLTS:190:BMAX")
  field(DOL4, "BEND:CLTS:190:BMIN")
  field(DOL5, "BEND:CLTS:190:BMIN")
  field(DOL6, "BEND:CLTS:190:BMIN")
  field(LNK1, "BEND:CLTS:190:BMAGX.HOPR")
  field(LNK2, "BEND:CLTS:190:BMAGY.HOPR")
  field(LNK3, "BEND:CLTS:190:BLEM.HOPR")
  field(LNK4, "BEND:CLTS:190:BMAGX.LOPR PP")
  field(LNK5, "BEND:CLTS:190:BMAGY.LOPR PP")
  field(LNK6, "BEND:CLTS:190:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:CLTS:190:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:CLTS:190:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:CLTS:190:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:CLTS:190:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:CLTS:190:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:190:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:CLTS:180:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:190:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:CLTS:180:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:CLTS:190:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:190:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:CLTS:180:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:CLTS:190:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:CLTS:190:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:CLTS:190:EDES NPP MS")
  field(INPB, "BEND:CLTS:190:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:CLTS:535:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "BEND:CLTS:535:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "BEND:CLTS:535:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "BEND:CLTS:535:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "BEND:CLTS:535:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "BEND:CLTS:535:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "BEND:CLTS:535:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "BEND:CLTS:535:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "BEND:CLTS:535:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "BEND:CLTS:535:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "BEND:CLTS:535:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:CLTS:535:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:CLTS:535:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:CLTS:535:EDES.PROC PP")
    field(LNK2, "BEND:CLTS:535:EACT.PROC PP")
    field(LNK3, "BEND:CLTS:535:EERR.DISA PP")
    field(LNK4, "BEND:CLTS:535:ECON.PROC PP")
    field(LNK5, "BEND:CLTS:535:BMAGX.PROC PP")
    field(LNK6, "BEND:CLTS:535:BMAGY.PROC PP")
    field(LNK7, "BEND:CLTS:535:BLEM.PROC PP")
    field(LNK8, "BEND:CLTS:535:BMOD.PROC PP")
    field(LNK9, "BEND:CLTS:535:EDESSAVE.PROC PP")
    field(LNKA, "BEND:CLTS:535:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:CLTS:535:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:CLTS:535:BMAX")
  field(DOL2, "BEND:CLTS:535:BMAX")
  field(DOL3, "BEND:CLTS:535:BMAX")
  field(DOL4, "BEND:CLTS:535:BMIN")
  field(DOL5, "BEND:CLTS:535:BMIN")
  field(DOL6, "BEND:CLTS:535:BMIN")
  field(LNK1, "BEND:CLTS:535:BMAGX.HOPR")
  field(LNK2, "BEND:CLTS:535:BMAGY.HOPR")
  field(LNK3, "BEND:CLTS:535:BLEM.HOPR")
  field(LNK4, "BEND:CLTS:535:BMAGX.LOPR PP")
  field(LNK5, "BEND:CLTS:535:BMAGY.LOPR PP")
  field(LNK6, "BEND:CLTS:535:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:CLTS:535:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:CLTS:535:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:CLTS:535:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:CLTS:535:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:CLTS:535:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:535:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:CLTS:505:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:535:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:CLTS:505:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:CLTS:535:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:CLTS:535:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:CLTS:505:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:CLTS:535:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:CLTS:535:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:CLTS:535:EDES NPP MS")
  field(INPB, "BEND:CLTS:535:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:CLTS:530:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "QUAD:CLTS:530:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "QUAD:CLTS:530:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:CLTS:530:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:CLTS:530:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "QUAD:CLTS:530:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "QUAD:CLTS:530:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "QUAD:CLTS:530:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:CLTS:530:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "QUAD:CLTS:530:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:CLTS:530:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:CLTS:530:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:CLTS:530:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:CLTS:530:EDES.PROC PP")
    field(LNK2, "QUAD:CLTS:530:EACT.PROC PP")
    field(LNK3, "QUAD:CLTS:530:EERR.DISA PP")
    field(LNK4, "QUAD:CLTS:530:ECON.PROC PP")
    field(LNK5, "QUAD:CLTS:530:BMAGX.PROC PP")
    field(LNK6, "QUAD:CLTS:530:BMAGY.PROC PP")
    field(LNK7, "QUAD:CLTS:530:BLEM.PROC PP")
    field(LNK8, "QUAD:CLTS:530:BMOD.PROC PP")
    field(LNK9, "QUAD:CLTS:530:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:CLTS:530:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:CLTS:530:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:CLTS:530:BMAX")
  field(DOL2, "QUAD:CLTS:530:BMAX")
  field(DOL3, "QUAD:CLTS:530:BMAX")
  field(DOL4, "QUAD:CLTS:530:BMIN")
  field(DOL5, "QUAD:CLTS:530:BMIN")
  field(DOL6, "QUAD:CLTS:530:BMIN")
  field(LNK1, "QUAD:CLTS:530:BMAGX.HOPR")
  field(LNK2, "QUAD:CLTS:530:BMAGY.HOPR")
  field(LNK3, "QUAD:CLTS:530:BLEM.HOPR")
  field(LNK4, "QUAD:CLTS:530:BMAGX.LOPR PP")
  field(LNK5, "QUAD:CLTS:530:BMAGY.LOPR PP")
  field(LNK6, "QUAD:CLTS:530:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:530:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:530:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:CLTS:530:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:CLTS:530:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:CLTS:530:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:530:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:CLTS:510:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:530:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:CLTS:510:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:CLTS:530:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:530:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:CLTS:510:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:CLTS:530:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:CLTS:530:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:CLTS:530:EDES NPP MS")
  field(INPB, "QUAD:CLTS:530:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:CLTS:540:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "QUAD:CLTS:540:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "QUAD:CLTS:540:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:CLTS:540:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:CLTS:540:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "QUAD:CLTS:540:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "QUAD:CLTS:540:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "QUAD:CLTS:540:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:CLTS:540:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "QUAD:CLTS:540:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:CLTS:540:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:CLTS:540:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:CLTS:540:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:CLTS:540:EDES.PROC PP")
    field(LNK2, "QUAD:CLTS:540:EACT.PROC PP")
    field(LNK3, "QUAD:CLTS:540:EERR.DISA PP")
    field(LNK4, "QUAD:CLTS:540:ECON.PROC PP")
    field(LNK5, "QUAD:CLTS:540:BMAGX.PROC PP")
    field(LNK6, "QUAD:CLTS:540:BMAGY.PROC PP")
    field(LNK7, "QUAD:CLTS:540:BLEM.PROC PP")
    field(LNK8, "QUAD:CLTS:540:BMOD.PROC PP")
    field(LNK9, "QUAD:CLTS:540:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:CLTS:540:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:CLTS:540:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:CLTS:540:BMAX")
  field(DOL2, "QUAD:CLTS:540:BMAX")
  field(DOL3, "QUAD:CLTS:540:BMAX")
  field(DOL4, "QUAD:CLTS:540:BMIN")
  field(DOL5, "QUAD:CLTS:540:BMIN")
  field(DOL6, "QUAD:CLTS:540:BMIN")
  field(LNK1, "QUAD:CLTS:540:BMAGX.HOPR")
  field(LNK2, "QUAD:CLTS:540:BMAGY.HOPR")
  field(LNK3, "QUAD:CLTS:540:BLEM.HOPR")
  field(LNK4, "QUAD:CLTS:540:BMAGX.LOPR PP")
  field(LNK5, "QUAD:CLTS:540:BMAGY.LOPR PP")
  field(LNK6, "QUAD:CLTS:540:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:540:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:540:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:CLTS:540:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:CLTS:540:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:CLTS:540:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:540:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:CLTS:500:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:540:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:CLTS:500:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:CLTS:540:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:540:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:CLTS:500:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:CLTS:540:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:CLTS:540:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:CLTS:540:EDES NPP MS")
  field(INPB, "QUAD:CLTS:540:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:CLTS:570:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BSY0:1:CU:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BSY0:1:CU:CTRL.RVAL")
  field(LNK1, "QUAD:CLTS:570:FUNC CA PP")
  field(DOL2, "MGNT:BSY0:1:CU:BENDCTRL.RVAL")
  field(LNK2, "QUAD:CLTS:570:FUNC CA PP")
  field(DOL3, "MGNT:BSY0:1:CU:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:CLTS:570:FUNC CA PP")
  field(DOL4, "MGNT:BSY0:1:CU:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:CLTS:570:FUNC CA PP")
  field(DOL5, "MGNT:BSY0:1:CU:QUADCTRL.RVAL")
  field(LNK5, "QUAD:CLTS:570:FUNC CA PP")
  field(DOL6, "MGNT:BSY0:1:CU:XCORCTRL.RVAL")
  field(LNK6, "QUAD:CLTS:570:FUNC CA PP")
  field(DOL7, "MGNT:BSY0:1:CU:YCORCTRL.RVAL")
  field(LNK7, "QUAD:CLTS:570:FUNC CA PP")
  field(DOL8, "MGNT:BSY0:1:CU:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:CLTS:570:FUNC CA PP")
  field(DOL9, "MGNT:BSY0:1:CU:KICKCTRL.RVAL")
  field(LNK9, "QUAD:CLTS:570:FUNC CA PP")
  field(DOLA, "MGNT:BSY0:1:CU:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:CLTS:570:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:CLTS:570:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:CLTS:570:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:CLTS:570:EDES.PROC PP")
    field(LNK2, "QUAD:CLTS:570:EACT.PROC PP")
    field(LNK3, "QUAD:CLTS:570:EERR.DISA PP")
    field(LNK4, "QUAD:CLTS:570:ECON.PROC PP")
    field(LNK5, "QUAD:CLTS:570:BMAGX.PROC PP")
    field(LNK6, "QUAD:CLTS:570:BMAGY.PROC PP")
    field(LNK7, "QUAD:CLTS:570:BLEM.PROC PP")
    field(LNK8, "QUAD:CLTS:570:BMOD.PROC PP")
    field(LNK9, "QUAD:CLTS:570:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:CLTS:570:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:CLTS:570:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:CLTS:570:BMAX")
  field(DOL2, "QUAD:CLTS:570:BMAX")
  field(DOL3, "QUAD:CLTS:570:BMAX")
  field(DOL4, "QUAD:CLTS:570:BMIN")
  field(DOL5, "QUAD:CLTS:570:BMIN")
  field(DOL6, "QUAD:CLTS:570:BMIN")
  field(LNK1, "QUAD:CLTS:570:BMAGX.HOPR")
  field(LNK2, "QUAD:CLTS:570:BMAGY.HOPR")
  field(LNK3, "QUAD:CLTS:570:BLEM.HOPR")
  field(LNK4, "QUAD:CLTS:570:BMAGX.LOPR PP")
  field(LNK5, "QUAD:CLTS:570:BMAGY.LOPR PP")
  field(LNK6, "QUAD:CLTS:570:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:570:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:CLTS:570:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:CLTS:570:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:CLTS:570:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:CLTS:570:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:570:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:CLTS:470:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:570:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:CLTS:470:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:CLTS:570:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:CLTS:570:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:CLTS:470:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:CLTS:570:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:CLTS:570:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:CLTS:570:EDES NPP MS")
  field(INPB, "QUAD:CLTS:570:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:SPH:170:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTH:1:CTRL.RVAL")
  field(LNK1, "BEND:SPH:170:FUNC CA PP")
  field(DOL2, "MGNT:SLTH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:SPH:170:FUNC CA PP")
  field(DOL3, "MGNT:SLTH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:SPH:170:FUNC CA PP")
  field(DOL4, "MGNT:SLTH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:SPH:170:FUNC CA PP")
  field(DOL5, "MGNT:SLTH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:SPH:170:FUNC CA PP")
  field(DOL6, "MGNT:SLTH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:SPH:170:FUNC CA PP")
  field(DOL7, "MGNT:SLTH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:SPH:170:FUNC CA PP")
  field(DOL8, "MGNT:SLTH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:SPH:170:FUNC CA PP")
  field(DOL9, "MGNT:SLTH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:SPH:170:FUNC CA PP")
  field(DOLA, "MGNT:SLTH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:SPH:170:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:SPH:170:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:SPH:170:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:SPH:170:EDES.PROC PP")
    field(LNK2, "BEND:SPH:170:EACT.PROC PP")
    field(LNK3, "BEND:SPH:170:EERR.DISA PP")
    field(LNK4, "BEND:SPH:170:ECON.PROC PP")
    field(LNK5, "BEND:SPH:170:BMAGX.PROC PP")
    field(LNK6, "BEND:SPH:170:BMAGY.PROC PP")
    field(LNK7, "BEND:SPH:170:BLEM.PROC PP")
    field(LNK8, "BEND:SPH:170:BMOD.PROC PP")
    field(LNK9, "BEND:SPH:170:EDESSAVE.PROC PP")
    field(LNKA, "BEND:SPH:170:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:SPH:170:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:SPH:170:BMAX")
  field(DOL2, "BEND:SPH:170:BMAX")
  field(DOL3, "BEND:SPH:170:BMAX")
  field(DOL4, "BEND:SPH:170:BMIN")
  field(DOL5, "BEND:SPH:170:BMIN")
  field(DOL6, "BEND:SPH:170:BMIN")
  field(LNK1, "BEND:SPH:170:BMAGX.HOPR")
  field(LNK2, "BEND:SPH:170:BMAGY.HOPR")
  field(LNK3, "BEND:SPH:170:BLEM.HOPR")
  field(LNK4, "BEND:SPH:170:BMAGX.LOPR PP")
  field(LNK5, "BEND:SPH:170:BMAGY.LOPR PP")
  field(LNK6, "BEND:SPH:170:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:SPH:170:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:SPH:170:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:SPH:170:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:SPH:170:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:SPH:170:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPH:170:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:SLTH:435:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPH:170:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:SLTH:435:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:SPH:170:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPH:170:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:SLTH:435:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:SPH:170:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:SPH:170:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:SPH:170:EDES NPP MS")
  field(INPB, "BEND:SPH:170:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:SPH:370:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SLTH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SLTH:1:CTRL.RVAL")
  field(LNK1, "BEND:SPH:370:FUNC CA PP")
  field(DOL2, "MGNT:SLTH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:SPH:370:FUNC CA PP")
  field(DOL3, "MGNT:SLTH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:SPH:370:FUNC CA PP")
  field(DOL4, "MGNT:SLTH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:SPH:370:FUNC CA PP")
  field(DOL5, "MGNT:SLTH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:SPH:370:FUNC CA PP")
  field(DOL6, "MGNT:SLTH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:SPH:370:FUNC CA PP")
  field(DOL7, "MGNT:SLTH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:SPH:370:FUNC CA PP")
  field(DOL8, "MGNT:SLTH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:SPH:370:FUNC CA PP")
  field(DOL9, "MGNT:SLTH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:SPH:370:FUNC CA PP")
  field(DOLA, "MGNT:SLTH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:SPH:370:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:SPH:370:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:SPH:370:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:SPH:370:EDES.PROC PP")
    field(LNK2, "BEND:SPH:370:EACT.PROC PP")
    field(LNK3, "BEND:SPH:370:EERR.DISA PP")
    field(LNK4, "BEND:SPH:370:ECON.PROC PP")
    field(LNK5, "BEND:SPH:370:BMAGX.PROC PP")
    field(LNK6, "BEND:SPH:370:BMAGY.PROC PP")
    field(LNK7, "BEND:SPH:370:BLEM.PROC PP")
    field(LNK8, "BEND:SPH:370:BMOD.PROC PP")
    field(LNK9, "BEND:SPH:370:EDESSAVE.PROC PP")
    field(LNKA, "BEND:SPH:370:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:SPH:370:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:SPH:370:BMAX")
  field(DOL2, "BEND:SPH:370:BMAX")
  field(DOL3, "BEND:SPH:370:BMAX")
  field(DOL4, "BEND:SPH:370:BMIN")
  field(DOL5, "BEND:SPH:370:BMIN")
  field(DOL6, "BEND:SPH:370:BMIN")
  field(LNK1, "BEND:SPH:370:BMAGX.HOPR")
  field(LNK2, "BEND:SPH:370:BMAGY.HOPR")
  field(LNK3, "BEND:SPH:370:BLEM.HOPR")
  field(LNK4, "BEND:SPH:370:BMAGX.LOPR PP")
  field(LNK5, "BEND:SPH:370:BMAGY.LOPR PP")
  field(LNK6, "BEND:SPH:370:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:SPH:370:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:SPH:370:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:SPH:370:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:SPH:370:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:SPH:370:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPH:370:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:SLTH:145:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPH:370:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:SLTH:145:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:SPH:370:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPH:370:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:SLTH:145:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:SPH:370:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:SPH:370:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:SPH:370:EDES NPP MS")
  field(INPB, "BEND:SPH:370:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:LTUH:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:LTUH:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:LTUH:1:CTRL CA PP")
  field(LNK2, "MGNT:LTUH:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:LTUH:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:LTUH:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:LTUH:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:LTUH:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:LTUH:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:LTUH:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:LTUH:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:LTUH:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:LTUH:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:LTUH:1:ALLSWITCH")
}

record(seq, "MGNT:LTUH:1:ALLSWITCH") {
  field(DOL1, "MGNT:LTUH:1:CTRL.FFVL")
  field(LNK1, "MGNT:LTUH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUH:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUH:1:CTRL")
}

record(bo, "MGNT:LTUH:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:LTUH:1:ALLSTARGO")
}

record(fanout, "MGNT:LTUH:1:ALLSTARGO") {
  field(LNK1, "MGNT:LTUH:1:ALLBENDSGO")
  field(LNK2, "MGNT:LTUH:1:ALLBTRMSGO")
  field(LNK3, "MGNT:LTUH:1:ALLLGPSSGO")
  field(LNK4, "MGNT:LTUH:1:ALLQUADSGO")
  field(LNK5, "MGNT:LTUH:1:ALLXCORSGO")
  field(LNK6, "MGNT:LTUH:1:ALLYCORSGO")
  field(FLNK, "MGNT:LTUH:1:ALLSTARGO_2")
}
record(fanout, "MGNT:LTUH:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:LTUH:1:ALLSOLNSGO")
  field(LNK2, "MGNT:LTUH:1:ALLKICKSGO")
  field(LNK3, "MGNT:LTUH:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:LTUH:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:LTUH:1:BENDSWITCH")
}

record(seq, "MGNT:LTUH:1:BENDSWITCH") {
  field(DOL1, "MGNT:LTUH:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:LTUH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUH:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUH:1:BENDCTRL")
}

record(seq, "MGNT:LTUH:1:ALLBENDSGO") {
  field(DOL1, "MGNT:LTUH:1:ALLSTAR")
  field(LNK1, "MGNT:LTUH:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:LTUH:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUH:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUH:1:BENDCTRL",20,10,0,0,"MGNT:LTUH:1:BENDCTRL")
#! Field("MGNT:LTUH:1:BENDCTRL.FLNK",16777215,1,"MGNT:LTUH:1:BENDCTRL.FLNK")
#! Link("MGNT:LTUH:1:BENDCTRL.FLNK","MGNT:LTUH:1:BENDSWITCH")
#! Field("MGNT:LTUH:1:BENDCTRL.FFVL",16777215,1,"MGNT:LTUH:1:BENDCTRL.FFVL")
#! Record("MGNT:LTUH:1:BENDSWITCH",460,322,0,0,"MGNT:LTUH:1:BENDSWITCH")
#! Field("MGNT:LTUH:1:BENDSWITCH.DOL1",16777215,0,"MGNT:LTUH:1:BENDSWITCH.DOL1")
#! Link("MGNT:LTUH:1:BENDSWITCH.DOL1","MGNT:LTUH:1:BENDCTRL.FFVL")
#! Field("MGNT:LTUH:1:BENDSWITCH.LNK1",16777215,1,"MGNT:LTUH:1:BENDSWITCH.LNK1")
#! Field("MGNT:LTUH:1:BENDSWITCH.FLNK",16777215,1,"MGNT:LTUH:1:BENDSWITCH.FLNK")
#! Record("MGNT:LTUH:1:ALLBENDSGO",240,96,0,0,"MGNT:LTUH:1:ALLBENDSGO")
#! Field("MGNT:LTUH:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:LTUH:1:ALLBENDSGO.DOL1")
#! Field("MGNT:LTUH:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:LTUH:1:ALLBENDSGO.LNK1")
#! Link("MGNT:LTUH:1:ALLBENDSGO.LNK1","MGNT:LTUH:1:ALLBENDS.VAL")
#! Record("MGNT:LTUH:1:ALLBENDS",540,102,0,0,"MGNT:LTUH:1:ALLBENDS")
#! Field("MGNT:LTUH:1:ALLBENDS.VAL",16777215,0,"MGNT:LTUH:1:ALLBENDS.VAL")
#! Field("MGNT:LTUH:1:ALLBENDS.FLNK",16777215,1,"MGNT:LTUH:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:LTUH:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LTUH:1:BTRMSWITCH")
}

record(seq, "MGNT:LTUH:1:BTRMSWITCH") {
  field(DOL1, "MGNT:LTUH:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:LTUH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUH:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUH:1:BTRMCTRL")
}

record(seq, "MGNT:LTUH:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:LTUH:1:ALLSTAR")
  field(LNK1, "MGNT:LTUH:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:LTUH:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUH:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUH:1:BTRMCTRL",20,10,0,0,"MGNT:LTUH:1:BTRMCTRL")
#! Field("MGNT:LTUH:1:BTRMCTRL.FLNK",16777215,1,"MGNT:LTUH:1:BTRMCTRL.FLNK")
#! Link("MGNT:LTUH:1:BTRMCTRL.FLNK","MGNT:LTUH:1:BTRMSWITCH")
#! Field("MGNT:LTUH:1:BTRMCTRL.FFVL",16777215,1,"MGNT:LTUH:1:BTRMCTRL.FFVL")
#! Record("MGNT:LTUH:1:BTRMSWITCH",460,322,0,0,"MGNT:LTUH:1:BTRMSWITCH")
#! Field("MGNT:LTUH:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:LTUH:1:BTRMSWITCH.DOL1")
#! Link("MGNT:LTUH:1:BTRMSWITCH.DOL1","MGNT:LTUH:1:BTRMCTRL.FFVL")
#! Field("MGNT:LTUH:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:LTUH:1:BTRMSWITCH.LNK1")
#! Field("MGNT:LTUH:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:LTUH:1:BTRMSWITCH.FLNK")
#! Record("MGNT:LTUH:1:ALLBTRMSGO",240,96,0,0,"MGNT:LTUH:1:ALLBTRMSGO")
#! Field("MGNT:LTUH:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:LTUH:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:LTUH:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:LTUH:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:LTUH:1:ALLBTRMSGO.LNK1","MGNT:LTUH:1:ALLBTRMS.VAL")
#! Record("MGNT:LTUH:1:ALLBTRMS",540,102,0,0,"MGNT:LTUH:1:ALLBTRMS")
#! Field("MGNT:LTUH:1:ALLBTRMS.VAL",16777215,0,"MGNT:LTUH:1:ALLBTRMS.VAL")
#! Field("MGNT:LTUH:1:ALLBTRMS.FLNK",16777215,1,"MGNT:LTUH:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:LTUH:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LTUH:1:LGPSSWITCH")
}

record(seq, "MGNT:LTUH:1:LGPSSWITCH") {
  field(DOL1, "MGNT:LTUH:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:LTUH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUH:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUH:1:LGPSCTRL")
}

record(seq, "MGNT:LTUH:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:LTUH:1:ALLSTAR")
  field(LNK1, "MGNT:LTUH:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:LTUH:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUH:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUH:1:LGPSCTRL",20,10,0,0,"MGNT:LTUH:1:LGPSCTRL")
#! Field("MGNT:LTUH:1:LGPSCTRL.FLNK",16777215,1,"MGNT:LTUH:1:LGPSCTRL.FLNK")
#! Link("MGNT:LTUH:1:LGPSCTRL.FLNK","MGNT:LTUH:1:LGPSSWITCH")
#! Field("MGNT:LTUH:1:LGPSCTRL.FFVL",16777215,1,"MGNT:LTUH:1:LGPSCTRL.FFVL")
#! Record("MGNT:LTUH:1:LGPSSWITCH",460,322,0,0,"MGNT:LTUH:1:LGPSSWITCH")
#! Field("MGNT:LTUH:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:LTUH:1:LGPSSWITCH.DOL1")
#! Link("MGNT:LTUH:1:LGPSSWITCH.DOL1","MGNT:LTUH:1:LGPSCTRL.FFVL")
#! Field("MGNT:LTUH:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:LTUH:1:LGPSSWITCH.LNK1")
#! Field("MGNT:LTUH:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:LTUH:1:LGPSSWITCH.FLNK")
#! Record("MGNT:LTUH:1:ALLLGPSSGO",240,96,0,0,"MGNT:LTUH:1:ALLLGPSSGO")
#! Field("MGNT:LTUH:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:LTUH:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:LTUH:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:LTUH:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:LTUH:1:ALLLGPSSGO.LNK1","MGNT:LTUH:1:ALLLGPSS.VAL")
#! Record("MGNT:LTUH:1:ALLLGPSS",540,102,0,0,"MGNT:LTUH:1:ALLLGPSS")
#! Field("MGNT:LTUH:1:ALLLGPSS.VAL",16777215,0,"MGNT:LTUH:1:ALLLGPSS.VAL")
#! Field("MGNT:LTUH:1:ALLLGPSS.FLNK",16777215,1,"MGNT:LTUH:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:LTUH:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:LTUH:1:QUADSWITCH")
}

record(seq, "MGNT:LTUH:1:QUADSWITCH") {
  field(DOL1, "MGNT:LTUH:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:LTUH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUH:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUH:1:QUADCTRL")
}

record(seq, "MGNT:LTUH:1:ALLQUADSGO") {
  field(DOL1, "MGNT:LTUH:1:ALLSTAR")
  field(LNK1, "MGNT:LTUH:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:LTUH:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUH:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUH:1:QUADCTRL",20,10,0,0,"MGNT:LTUH:1:QUADCTRL")
#! Field("MGNT:LTUH:1:QUADCTRL.FLNK",16777215,1,"MGNT:LTUH:1:QUADCTRL.FLNK")
#! Link("MGNT:LTUH:1:QUADCTRL.FLNK","MGNT:LTUH:1:QUADSWITCH")
#! Field("MGNT:LTUH:1:QUADCTRL.FFVL",16777215,1,"MGNT:LTUH:1:QUADCTRL.FFVL")
#! Record("MGNT:LTUH:1:QUADSWITCH",460,322,0,0,"MGNT:LTUH:1:QUADSWITCH")
#! Field("MGNT:LTUH:1:QUADSWITCH.DOL1",16777215,0,"MGNT:LTUH:1:QUADSWITCH.DOL1")
#! Link("MGNT:LTUH:1:QUADSWITCH.DOL1","MGNT:LTUH:1:QUADCTRL.FFVL")
#! Field("MGNT:LTUH:1:QUADSWITCH.LNK1",16777215,1,"MGNT:LTUH:1:QUADSWITCH.LNK1")
#! Field("MGNT:LTUH:1:QUADSWITCH.FLNK",16777215,1,"MGNT:LTUH:1:QUADSWITCH.FLNK")
#! Record("MGNT:LTUH:1:ALLQUADSGO",240,96,0,0,"MGNT:LTUH:1:ALLQUADSGO")
#! Field("MGNT:LTUH:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:LTUH:1:ALLQUADSGO.DOL1")
#! Field("MGNT:LTUH:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:LTUH:1:ALLQUADSGO.LNK1")
#! Link("MGNT:LTUH:1:ALLQUADSGO.LNK1","MGNT:LTUH:1:ALLQUADS.VAL")
#! Record("MGNT:LTUH:1:ALLQUADS",540,102,0,0,"MGNT:LTUH:1:ALLQUADS")
#! Field("MGNT:LTUH:1:ALLQUADS.VAL",16777215,0,"MGNT:LTUH:1:ALLQUADS.VAL")
#! Field("MGNT:LTUH:1:ALLQUADS.FLNK",16777215,1,"MGNT:LTUH:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:LTUH:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:LTUH:1:XCORSWITCH")
}

record(seq, "MGNT:LTUH:1:XCORSWITCH") {
  field(DOL1, "MGNT:LTUH:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:LTUH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUH:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUH:1:XCORCTRL")
}

record(seq, "MGNT:LTUH:1:ALLXCORSGO") {
  field(DOL1, "MGNT:LTUH:1:ALLSTAR")
  field(LNK1, "MGNT:LTUH:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:LTUH:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUH:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUH:1:XCORCTRL",20,10,0,0,"MGNT:LTUH:1:XCORCTRL")
#! Field("MGNT:LTUH:1:XCORCTRL.FLNK",16777215,1,"MGNT:LTUH:1:XCORCTRL.FLNK")
#! Link("MGNT:LTUH:1:XCORCTRL.FLNK","MGNT:LTUH:1:XCORSWITCH")
#! Field("MGNT:LTUH:1:XCORCTRL.FFVL",16777215,1,"MGNT:LTUH:1:XCORCTRL.FFVL")
#! Record("MGNT:LTUH:1:XCORSWITCH",460,322,0,0,"MGNT:LTUH:1:XCORSWITCH")
#! Field("MGNT:LTUH:1:XCORSWITCH.DOL1",16777215,0,"MGNT:LTUH:1:XCORSWITCH.DOL1")
#! Link("MGNT:LTUH:1:XCORSWITCH.DOL1","MGNT:LTUH:1:XCORCTRL.FFVL")
#! Field("MGNT:LTUH:1:XCORSWITCH.LNK1",16777215,1,"MGNT:LTUH:1:XCORSWITCH.LNK1")
#! Field("MGNT:LTUH:1:XCORSWITCH.FLNK",16777215,1,"MGNT:LTUH:1:XCORSWITCH.FLNK")
#! Record("MGNT:LTUH:1:ALLXCORSGO",240,96,0,0,"MGNT:LTUH:1:ALLXCORSGO")
#! Field("MGNT:LTUH:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:LTUH:1:ALLXCORSGO.DOL1")
#! Field("MGNT:LTUH:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:LTUH:1:ALLXCORSGO.LNK1")
#! Link("MGNT:LTUH:1:ALLXCORSGO.LNK1","MGNT:LTUH:1:ALLXCORS.VAL")
#! Record("MGNT:LTUH:1:ALLXCORS",540,102,0,0,"MGNT:LTUH:1:ALLXCORS")
#! Field("MGNT:LTUH:1:ALLXCORS.VAL",16777215,0,"MGNT:LTUH:1:ALLXCORS.VAL")
#! Field("MGNT:LTUH:1:ALLXCORS.FLNK",16777215,1,"MGNT:LTUH:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:LTUH:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:LTUH:1:YCORSWITCH")
}

record(seq, "MGNT:LTUH:1:YCORSWITCH") {
  field(DOL1, "MGNT:LTUH:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:LTUH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUH:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUH:1:YCORCTRL")
}

record(seq, "MGNT:LTUH:1:ALLYCORSGO") {
  field(DOL1, "MGNT:LTUH:1:ALLSTAR")
  field(LNK1, "MGNT:LTUH:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:LTUH:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUH:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUH:1:YCORCTRL",20,10,0,0,"MGNT:LTUH:1:YCORCTRL")
#! Field("MGNT:LTUH:1:YCORCTRL.FLNK",16777215,1,"MGNT:LTUH:1:YCORCTRL.FLNK")
#! Link("MGNT:LTUH:1:YCORCTRL.FLNK","MGNT:LTUH:1:YCORSWITCH")
#! Field("MGNT:LTUH:1:YCORCTRL.FFVL",16777215,1,"MGNT:LTUH:1:YCORCTRL.FFVL")
#! Record("MGNT:LTUH:1:YCORSWITCH",460,322,0,0,"MGNT:LTUH:1:YCORSWITCH")
#! Field("MGNT:LTUH:1:YCORSWITCH.DOL1",16777215,0,"MGNT:LTUH:1:YCORSWITCH.DOL1")
#! Link("MGNT:LTUH:1:YCORSWITCH.DOL1","MGNT:LTUH:1:YCORCTRL.FFVL")
#! Field("MGNT:LTUH:1:YCORSWITCH.LNK1",16777215,1,"MGNT:LTUH:1:YCORSWITCH.LNK1")
#! Field("MGNT:LTUH:1:YCORSWITCH.FLNK",16777215,1,"MGNT:LTUH:1:YCORSWITCH.FLNK")
#! Record("MGNT:LTUH:1:ALLYCORSGO",240,96,0,0,"MGNT:LTUH:1:ALLYCORSGO")
#! Field("MGNT:LTUH:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:LTUH:1:ALLYCORSGO.DOL1")
#! Field("MGNT:LTUH:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:LTUH:1:ALLYCORSGO.LNK1")
#! Link("MGNT:LTUH:1:ALLYCORSGO.LNK1","MGNT:LTUH:1:ALLYCORS.VAL")
#! Record("MGNT:LTUH:1:ALLYCORS",540,102,0,0,"MGNT:LTUH:1:ALLYCORS")
#! Field("MGNT:LTUH:1:ALLYCORS.VAL",16777215,0,"MGNT:LTUH:1:ALLYCORS.VAL")
#! Field("MGNT:LTUH:1:ALLYCORS.FLNK",16777215,1,"MGNT:LTUH:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:LTUH:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:LTUH:1:SOLNSWITCH")
}

record(seq, "MGNT:LTUH:1:SOLNSWITCH") {
  field(DOL1, "MGNT:LTUH:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:LTUH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUH:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUH:1:SOLNCTRL")
}

record(seq, "MGNT:LTUH:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:LTUH:1:ALLSTAR")
  field(LNK1, "MGNT:LTUH:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:LTUH:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUH:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUH:1:SOLNCTRL",20,10,0,0,"MGNT:LTUH:1:SOLNCTRL")
#! Field("MGNT:LTUH:1:SOLNCTRL.FLNK",16777215,1,"MGNT:LTUH:1:SOLNCTRL.FLNK")
#! Link("MGNT:LTUH:1:SOLNCTRL.FLNK","MGNT:LTUH:1:SOLNSWITCH")
#! Field("MGNT:LTUH:1:SOLNCTRL.FFVL",16777215,1,"MGNT:LTUH:1:SOLNCTRL.FFVL")
#! Record("MGNT:LTUH:1:SOLNSWITCH",460,322,0,0,"MGNT:LTUH:1:SOLNSWITCH")
#! Field("MGNT:LTUH:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:LTUH:1:SOLNSWITCH.DOL1")
#! Link("MGNT:LTUH:1:SOLNSWITCH.DOL1","MGNT:LTUH:1:SOLNCTRL.FFVL")
#! Field("MGNT:LTUH:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:LTUH:1:SOLNSWITCH.LNK1")
#! Field("MGNT:LTUH:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:LTUH:1:SOLNSWITCH.FLNK")
#! Record("MGNT:LTUH:1:ALLSOLNSGO",240,96,0,0,"MGNT:LTUH:1:ALLSOLNSGO")
#! Field("MGNT:LTUH:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:LTUH:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:LTUH:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:LTUH:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:LTUH:1:ALLSOLNSGO.LNK1","MGNT:LTUH:1:ALLSOLNS.VAL")
#! Record("MGNT:LTUH:1:ALLSOLNS",540,102,0,0,"MGNT:LTUH:1:ALLSOLNS")
#! Field("MGNT:LTUH:1:ALLSOLNS.VAL",16777215,0,"MGNT:LTUH:1:ALLSOLNS.VAL")
#! Field("MGNT:LTUH:1:ALLSOLNS.FLNK",16777215,1,"MGNT:LTUH:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:LTUH:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:LTUH:1:KICKSWITCH")
}

record(seq, "MGNT:LTUH:1:KICKSWITCH") {
  field(DOL1, "MGNT:LTUH:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:LTUH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUH:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUH:1:KICKCTRL")
}

record(seq, "MGNT:LTUH:1:ALLKICKSGO") {
  field(DOL1, "MGNT:LTUH:1:ALLSTAR")
  field(LNK1, "MGNT:LTUH:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:LTUH:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUH:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUH:1:KICKCTRL",20,10,0,0,"MGNT:LTUH:1:KICKCTRL")
#! Field("MGNT:LTUH:1:KICKCTRL.FLNK",16777215,1,"MGNT:LTUH:1:KICKCTRL.FLNK")
#! Link("MGNT:LTUH:1:KICKCTRL.FLNK","MGNT:LTUH:1:KICKSWITCH")
#! Field("MGNT:LTUH:1:KICKCTRL.FFVL",16777215,1,"MGNT:LTUH:1:KICKCTRL.FFVL")
#! Record("MGNT:LTUH:1:KICKSWITCH",460,322,0,0,"MGNT:LTUH:1:KICKSWITCH")
#! Field("MGNT:LTUH:1:KICKSWITCH.DOL1",16777215,0,"MGNT:LTUH:1:KICKSWITCH.DOL1")
#! Link("MGNT:LTUH:1:KICKSWITCH.DOL1","MGNT:LTUH:1:KICKCTRL.FFVL")
#! Field("MGNT:LTUH:1:KICKSWITCH.LNK1",16777215,1,"MGNT:LTUH:1:KICKSWITCH.LNK1")
#! Field("MGNT:LTUH:1:KICKSWITCH.FLNK",16777215,1,"MGNT:LTUH:1:KICKSWITCH.FLNK")
#! Record("MGNT:LTUH:1:ALLKICKSGO",240,96,0,0,"MGNT:LTUH:1:ALLKICKSGO")
#! Field("MGNT:LTUH:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:LTUH:1:ALLKICKSGO.DOL1")
#! Field("MGNT:LTUH:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:LTUH:1:ALLKICKSGO.LNK1")
#! Link("MGNT:LTUH:1:ALLKICKSGO.LNK1","MGNT:LTUH:1:ALLKICKS.VAL")
#! Record("MGNT:LTUH:1:ALLKICKS",540,102,0,0,"MGNT:LTUH:1:ALLKICKS")
#! Field("MGNT:LTUH:1:ALLKICKS.VAL",16777215,0,"MGNT:LTUH:1:ALLKICKS.VAL")
#! Field("MGNT:LTUH:1:ALLKICKS.FLNK",16777215,1,"MGNT:LTUH:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:LTUH:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:LTUH:1:SEXTSWITCH")
}

record(seq, "MGNT:LTUH:1:SEXTSWITCH") {
  field(DOL1, "MGNT:LTUH:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:LTUH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUH:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUH:1:SEXTCTRL")
}

record(seq, "MGNT:LTUH:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:LTUH:1:ALLSTAR")
  field(LNK1, "MGNT:LTUH:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:LTUH:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUH:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUH:1:SEXTCTRL",20,10,0,0,"MGNT:LTUH:1:SEXTCTRL")
#! Field("MGNT:LTUH:1:SEXTCTRL.FLNK",16777215,1,"MGNT:LTUH:1:SEXTCTRL.FLNK")
#! Link("MGNT:LTUH:1:SEXTCTRL.FLNK","MGNT:LTUH:1:SEXTSWITCH")
#! Field("MGNT:LTUH:1:SEXTCTRL.FFVL",16777215,1,"MGNT:LTUH:1:SEXTCTRL.FFVL")
#! Record("MGNT:LTUH:1:SEXTSWITCH",460,322,0,0,"MGNT:LTUH:1:SEXTSWITCH")
#! Field("MGNT:LTUH:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:LTUH:1:SEXTSWITCH.DOL1")
#! Link("MGNT:LTUH:1:SEXTSWITCH.DOL1","MGNT:LTUH:1:SEXTCTRL.FFVL")
#! Field("MGNT:LTUH:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:LTUH:1:SEXTSWITCH.LNK1")
#! Field("MGNT:LTUH:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:LTUH:1:SEXTSWITCH.FLNK")
#! Record("MGNT:LTUH:1:ALLSEXTSGO",240,96,0,0,"MGNT:LTUH:1:ALLSEXTSGO")
#! Field("MGNT:LTUH:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:LTUH:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:LTUH:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:LTUH:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:LTUH:1:ALLSEXTSGO.LNK1","MGNT:LTUH:1:ALLSEXTS.VAL")
#! Record("MGNT:LTUH:1:ALLSEXTS",540,102,0,0,"MGNT:LTUH:1:ALLSEXTS")
#! Field("MGNT:LTUH:1:ALLSEXTS.VAL",16777215,0,"MGNT:LTUH:1:ALLSEXTS.VAL")
#! Field("MGNT:LTUH:1:ALLSEXTS.FLNK",16777215,1,"MGNT:LTUH:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:LTUS:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:LTUS:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:LTUS:1:CTRL CA PP")
  field(LNK2, "MGNT:LTUS:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:LTUS:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:LTUS:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:LTUS:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:LTUS:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:LTUS:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:LTUS:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:LTUS:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:LTUS:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:LTUS:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:LTUS:1:ALLSWITCH")
}

record(seq, "MGNT:LTUS:1:ALLSWITCH") {
  field(DOL1, "MGNT:LTUS:1:CTRL.FFVL")
  field(LNK1, "MGNT:LTUS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUS:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUS:1:CTRL")
}

record(bo, "MGNT:LTUS:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:LTUS:1:ALLSTARGO")
}

record(fanout, "MGNT:LTUS:1:ALLSTARGO") {
  field(LNK1, "MGNT:LTUS:1:ALLBENDSGO")
  field(LNK2, "MGNT:LTUS:1:ALLBTRMSGO")
  field(LNK3, "MGNT:LTUS:1:ALLLGPSSGO")
  field(LNK4, "MGNT:LTUS:1:ALLQUADSGO")
  field(LNK5, "MGNT:LTUS:1:ALLXCORSGO")
  field(LNK6, "MGNT:LTUS:1:ALLYCORSGO")
  field(FLNK, "MGNT:LTUS:1:ALLSTARGO_2")
}
record(fanout, "MGNT:LTUS:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:LTUS:1:ALLSOLNSGO")
  field(LNK2, "MGNT:LTUS:1:ALLKICKSGO")
  field(LNK3, "MGNT:LTUS:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:LTUS:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:LTUS:1:BENDSWITCH")
}

record(seq, "MGNT:LTUS:1:BENDSWITCH") {
  field(DOL1, "MGNT:LTUS:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:LTUS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUS:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUS:1:BENDCTRL")
}

record(seq, "MGNT:LTUS:1:ALLBENDSGO") {
  field(DOL1, "MGNT:LTUS:1:ALLSTAR")
  field(LNK1, "MGNT:LTUS:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:LTUS:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUS:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUS:1:BENDCTRL",20,10,0,0,"MGNT:LTUS:1:BENDCTRL")
#! Field("MGNT:LTUS:1:BENDCTRL.FLNK",16777215,1,"MGNT:LTUS:1:BENDCTRL.FLNK")
#! Link("MGNT:LTUS:1:BENDCTRL.FLNK","MGNT:LTUS:1:BENDSWITCH")
#! Field("MGNT:LTUS:1:BENDCTRL.FFVL",16777215,1,"MGNT:LTUS:1:BENDCTRL.FFVL")
#! Record("MGNT:LTUS:1:BENDSWITCH",460,322,0,0,"MGNT:LTUS:1:BENDSWITCH")
#! Field("MGNT:LTUS:1:BENDSWITCH.DOL1",16777215,0,"MGNT:LTUS:1:BENDSWITCH.DOL1")
#! Link("MGNT:LTUS:1:BENDSWITCH.DOL1","MGNT:LTUS:1:BENDCTRL.FFVL")
#! Field("MGNT:LTUS:1:BENDSWITCH.LNK1",16777215,1,"MGNT:LTUS:1:BENDSWITCH.LNK1")
#! Field("MGNT:LTUS:1:BENDSWITCH.FLNK",16777215,1,"MGNT:LTUS:1:BENDSWITCH.FLNK")
#! Record("MGNT:LTUS:1:ALLBENDSGO",240,96,0,0,"MGNT:LTUS:1:ALLBENDSGO")
#! Field("MGNT:LTUS:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:LTUS:1:ALLBENDSGO.DOL1")
#! Field("MGNT:LTUS:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:LTUS:1:ALLBENDSGO.LNK1")
#! Link("MGNT:LTUS:1:ALLBENDSGO.LNK1","MGNT:LTUS:1:ALLBENDS.VAL")
#! Record("MGNT:LTUS:1:ALLBENDS",540,102,0,0,"MGNT:LTUS:1:ALLBENDS")
#! Field("MGNT:LTUS:1:ALLBENDS.VAL",16777215,0,"MGNT:LTUS:1:ALLBENDS.VAL")
#! Field("MGNT:LTUS:1:ALLBENDS.FLNK",16777215,1,"MGNT:LTUS:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:LTUS:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LTUS:1:BTRMSWITCH")
}

record(seq, "MGNT:LTUS:1:BTRMSWITCH") {
  field(DOL1, "MGNT:LTUS:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:LTUS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUS:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUS:1:BTRMCTRL")
}

record(seq, "MGNT:LTUS:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:LTUS:1:ALLSTAR")
  field(LNK1, "MGNT:LTUS:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:LTUS:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUS:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUS:1:BTRMCTRL",20,10,0,0,"MGNT:LTUS:1:BTRMCTRL")
#! Field("MGNT:LTUS:1:BTRMCTRL.FLNK",16777215,1,"MGNT:LTUS:1:BTRMCTRL.FLNK")
#! Link("MGNT:LTUS:1:BTRMCTRL.FLNK","MGNT:LTUS:1:BTRMSWITCH")
#! Field("MGNT:LTUS:1:BTRMCTRL.FFVL",16777215,1,"MGNT:LTUS:1:BTRMCTRL.FFVL")
#! Record("MGNT:LTUS:1:BTRMSWITCH",460,322,0,0,"MGNT:LTUS:1:BTRMSWITCH")
#! Field("MGNT:LTUS:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:LTUS:1:BTRMSWITCH.DOL1")
#! Link("MGNT:LTUS:1:BTRMSWITCH.DOL1","MGNT:LTUS:1:BTRMCTRL.FFVL")
#! Field("MGNT:LTUS:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:LTUS:1:BTRMSWITCH.LNK1")
#! Field("MGNT:LTUS:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:LTUS:1:BTRMSWITCH.FLNK")
#! Record("MGNT:LTUS:1:ALLBTRMSGO",240,96,0,0,"MGNT:LTUS:1:ALLBTRMSGO")
#! Field("MGNT:LTUS:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:LTUS:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:LTUS:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:LTUS:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:LTUS:1:ALLBTRMSGO.LNK1","MGNT:LTUS:1:ALLBTRMS.VAL")
#! Record("MGNT:LTUS:1:ALLBTRMS",540,102,0,0,"MGNT:LTUS:1:ALLBTRMS")
#! Field("MGNT:LTUS:1:ALLBTRMS.VAL",16777215,0,"MGNT:LTUS:1:ALLBTRMS.VAL")
#! Field("MGNT:LTUS:1:ALLBTRMS.FLNK",16777215,1,"MGNT:LTUS:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:LTUS:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:LTUS:1:LGPSSWITCH")
}

record(seq, "MGNT:LTUS:1:LGPSSWITCH") {
  field(DOL1, "MGNT:LTUS:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:LTUS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUS:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUS:1:LGPSCTRL")
}

record(seq, "MGNT:LTUS:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:LTUS:1:ALLSTAR")
  field(LNK1, "MGNT:LTUS:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:LTUS:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUS:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUS:1:LGPSCTRL",20,10,0,0,"MGNT:LTUS:1:LGPSCTRL")
#! Field("MGNT:LTUS:1:LGPSCTRL.FLNK",16777215,1,"MGNT:LTUS:1:LGPSCTRL.FLNK")
#! Link("MGNT:LTUS:1:LGPSCTRL.FLNK","MGNT:LTUS:1:LGPSSWITCH")
#! Field("MGNT:LTUS:1:LGPSCTRL.FFVL",16777215,1,"MGNT:LTUS:1:LGPSCTRL.FFVL")
#! Record("MGNT:LTUS:1:LGPSSWITCH",460,322,0,0,"MGNT:LTUS:1:LGPSSWITCH")
#! Field("MGNT:LTUS:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:LTUS:1:LGPSSWITCH.DOL1")
#! Link("MGNT:LTUS:1:LGPSSWITCH.DOL1","MGNT:LTUS:1:LGPSCTRL.FFVL")
#! Field("MGNT:LTUS:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:LTUS:1:LGPSSWITCH.LNK1")
#! Field("MGNT:LTUS:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:LTUS:1:LGPSSWITCH.FLNK")
#! Record("MGNT:LTUS:1:ALLLGPSSGO",240,96,0,0,"MGNT:LTUS:1:ALLLGPSSGO")
#! Field("MGNT:LTUS:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:LTUS:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:LTUS:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:LTUS:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:LTUS:1:ALLLGPSSGO.LNK1","MGNT:LTUS:1:ALLLGPSS.VAL")
#! Record("MGNT:LTUS:1:ALLLGPSS",540,102,0,0,"MGNT:LTUS:1:ALLLGPSS")
#! Field("MGNT:LTUS:1:ALLLGPSS.VAL",16777215,0,"MGNT:LTUS:1:ALLLGPSS.VAL")
#! Field("MGNT:LTUS:1:ALLLGPSS.FLNK",16777215,1,"MGNT:LTUS:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:LTUS:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:LTUS:1:QUADSWITCH")
}

record(seq, "MGNT:LTUS:1:QUADSWITCH") {
  field(DOL1, "MGNT:LTUS:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:LTUS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUS:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUS:1:QUADCTRL")
}

record(seq, "MGNT:LTUS:1:ALLQUADSGO") {
  field(DOL1, "MGNT:LTUS:1:ALLSTAR")
  field(LNK1, "MGNT:LTUS:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:LTUS:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUS:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUS:1:QUADCTRL",20,10,0,0,"MGNT:LTUS:1:QUADCTRL")
#! Field("MGNT:LTUS:1:QUADCTRL.FLNK",16777215,1,"MGNT:LTUS:1:QUADCTRL.FLNK")
#! Link("MGNT:LTUS:1:QUADCTRL.FLNK","MGNT:LTUS:1:QUADSWITCH")
#! Field("MGNT:LTUS:1:QUADCTRL.FFVL",16777215,1,"MGNT:LTUS:1:QUADCTRL.FFVL")
#! Record("MGNT:LTUS:1:QUADSWITCH",460,322,0,0,"MGNT:LTUS:1:QUADSWITCH")
#! Field("MGNT:LTUS:1:QUADSWITCH.DOL1",16777215,0,"MGNT:LTUS:1:QUADSWITCH.DOL1")
#! Link("MGNT:LTUS:1:QUADSWITCH.DOL1","MGNT:LTUS:1:QUADCTRL.FFVL")
#! Field("MGNT:LTUS:1:QUADSWITCH.LNK1",16777215,1,"MGNT:LTUS:1:QUADSWITCH.LNK1")
#! Field("MGNT:LTUS:1:QUADSWITCH.FLNK",16777215,1,"MGNT:LTUS:1:QUADSWITCH.FLNK")
#! Record("MGNT:LTUS:1:ALLQUADSGO",240,96,0,0,"MGNT:LTUS:1:ALLQUADSGO")
#! Field("MGNT:LTUS:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:LTUS:1:ALLQUADSGO.DOL1")
#! Field("MGNT:LTUS:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:LTUS:1:ALLQUADSGO.LNK1")
#! Link("MGNT:LTUS:1:ALLQUADSGO.LNK1","MGNT:LTUS:1:ALLQUADS.VAL")
#! Record("MGNT:LTUS:1:ALLQUADS",540,102,0,0,"MGNT:LTUS:1:ALLQUADS")
#! Field("MGNT:LTUS:1:ALLQUADS.VAL",16777215,0,"MGNT:LTUS:1:ALLQUADS.VAL")
#! Field("MGNT:LTUS:1:ALLQUADS.FLNK",16777215,1,"MGNT:LTUS:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:LTUS:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:LTUS:1:XCORSWITCH")
}

record(seq, "MGNT:LTUS:1:XCORSWITCH") {
  field(DOL1, "MGNT:LTUS:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:LTUS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUS:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUS:1:XCORCTRL")
}

record(seq, "MGNT:LTUS:1:ALLXCORSGO") {
  field(DOL1, "MGNT:LTUS:1:ALLSTAR")
  field(LNK1, "MGNT:LTUS:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:LTUS:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUS:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUS:1:XCORCTRL",20,10,0,0,"MGNT:LTUS:1:XCORCTRL")
#! Field("MGNT:LTUS:1:XCORCTRL.FLNK",16777215,1,"MGNT:LTUS:1:XCORCTRL.FLNK")
#! Link("MGNT:LTUS:1:XCORCTRL.FLNK","MGNT:LTUS:1:XCORSWITCH")
#! Field("MGNT:LTUS:1:XCORCTRL.FFVL",16777215,1,"MGNT:LTUS:1:XCORCTRL.FFVL")
#! Record("MGNT:LTUS:1:XCORSWITCH",460,322,0,0,"MGNT:LTUS:1:XCORSWITCH")
#! Field("MGNT:LTUS:1:XCORSWITCH.DOL1",16777215,0,"MGNT:LTUS:1:XCORSWITCH.DOL1")
#! Link("MGNT:LTUS:1:XCORSWITCH.DOL1","MGNT:LTUS:1:XCORCTRL.FFVL")
#! Field("MGNT:LTUS:1:XCORSWITCH.LNK1",16777215,1,"MGNT:LTUS:1:XCORSWITCH.LNK1")
#! Field("MGNT:LTUS:1:XCORSWITCH.FLNK",16777215,1,"MGNT:LTUS:1:XCORSWITCH.FLNK")
#! Record("MGNT:LTUS:1:ALLXCORSGO",240,96,0,0,"MGNT:LTUS:1:ALLXCORSGO")
#! Field("MGNT:LTUS:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:LTUS:1:ALLXCORSGO.DOL1")
#! Field("MGNT:LTUS:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:LTUS:1:ALLXCORSGO.LNK1")
#! Link("MGNT:LTUS:1:ALLXCORSGO.LNK1","MGNT:LTUS:1:ALLXCORS.VAL")
#! Record("MGNT:LTUS:1:ALLXCORS",540,102,0,0,"MGNT:LTUS:1:ALLXCORS")
#! Field("MGNT:LTUS:1:ALLXCORS.VAL",16777215,0,"MGNT:LTUS:1:ALLXCORS.VAL")
#! Field("MGNT:LTUS:1:ALLXCORS.FLNK",16777215,1,"MGNT:LTUS:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:LTUS:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:LTUS:1:YCORSWITCH")
}

record(seq, "MGNT:LTUS:1:YCORSWITCH") {
  field(DOL1, "MGNT:LTUS:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:LTUS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUS:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUS:1:YCORCTRL")
}

record(seq, "MGNT:LTUS:1:ALLYCORSGO") {
  field(DOL1, "MGNT:LTUS:1:ALLSTAR")
  field(LNK1, "MGNT:LTUS:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:LTUS:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUS:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUS:1:YCORCTRL",20,10,0,0,"MGNT:LTUS:1:YCORCTRL")
#! Field("MGNT:LTUS:1:YCORCTRL.FLNK",16777215,1,"MGNT:LTUS:1:YCORCTRL.FLNK")
#! Link("MGNT:LTUS:1:YCORCTRL.FLNK","MGNT:LTUS:1:YCORSWITCH")
#! Field("MGNT:LTUS:1:YCORCTRL.FFVL",16777215,1,"MGNT:LTUS:1:YCORCTRL.FFVL")
#! Record("MGNT:LTUS:1:YCORSWITCH",460,322,0,0,"MGNT:LTUS:1:YCORSWITCH")
#! Field("MGNT:LTUS:1:YCORSWITCH.DOL1",16777215,0,"MGNT:LTUS:1:YCORSWITCH.DOL1")
#! Link("MGNT:LTUS:1:YCORSWITCH.DOL1","MGNT:LTUS:1:YCORCTRL.FFVL")
#! Field("MGNT:LTUS:1:YCORSWITCH.LNK1",16777215,1,"MGNT:LTUS:1:YCORSWITCH.LNK1")
#! Field("MGNT:LTUS:1:YCORSWITCH.FLNK",16777215,1,"MGNT:LTUS:1:YCORSWITCH.FLNK")
#! Record("MGNT:LTUS:1:ALLYCORSGO",240,96,0,0,"MGNT:LTUS:1:ALLYCORSGO")
#! Field("MGNT:LTUS:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:LTUS:1:ALLYCORSGO.DOL1")
#! Field("MGNT:LTUS:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:LTUS:1:ALLYCORSGO.LNK1")
#! Link("MGNT:LTUS:1:ALLYCORSGO.LNK1","MGNT:LTUS:1:ALLYCORS.VAL")
#! Record("MGNT:LTUS:1:ALLYCORS",540,102,0,0,"MGNT:LTUS:1:ALLYCORS")
#! Field("MGNT:LTUS:1:ALLYCORS.VAL",16777215,0,"MGNT:LTUS:1:ALLYCORS.VAL")
#! Field("MGNT:LTUS:1:ALLYCORS.FLNK",16777215,1,"MGNT:LTUS:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:LTUS:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:LTUS:1:SOLNSWITCH")
}

record(seq, "MGNT:LTUS:1:SOLNSWITCH") {
  field(DOL1, "MGNT:LTUS:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:LTUS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUS:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUS:1:SOLNCTRL")
}

record(seq, "MGNT:LTUS:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:LTUS:1:ALLSTAR")
  field(LNK1, "MGNT:LTUS:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:LTUS:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUS:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUS:1:SOLNCTRL",20,10,0,0,"MGNT:LTUS:1:SOLNCTRL")
#! Field("MGNT:LTUS:1:SOLNCTRL.FLNK",16777215,1,"MGNT:LTUS:1:SOLNCTRL.FLNK")
#! Link("MGNT:LTUS:1:SOLNCTRL.FLNK","MGNT:LTUS:1:SOLNSWITCH")
#! Field("MGNT:LTUS:1:SOLNCTRL.FFVL",16777215,1,"MGNT:LTUS:1:SOLNCTRL.FFVL")
#! Record("MGNT:LTUS:1:SOLNSWITCH",460,322,0,0,"MGNT:LTUS:1:SOLNSWITCH")
#! Field("MGNT:LTUS:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:LTUS:1:SOLNSWITCH.DOL1")
#! Link("MGNT:LTUS:1:SOLNSWITCH.DOL1","MGNT:LTUS:1:SOLNCTRL.FFVL")
#! Field("MGNT:LTUS:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:LTUS:1:SOLNSWITCH.LNK1")
#! Field("MGNT:LTUS:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:LTUS:1:SOLNSWITCH.FLNK")
#! Record("MGNT:LTUS:1:ALLSOLNSGO",240,96,0,0,"MGNT:LTUS:1:ALLSOLNSGO")
#! Field("MGNT:LTUS:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:LTUS:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:LTUS:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:LTUS:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:LTUS:1:ALLSOLNSGO.LNK1","MGNT:LTUS:1:ALLSOLNS.VAL")
#! Record("MGNT:LTUS:1:ALLSOLNS",540,102,0,0,"MGNT:LTUS:1:ALLSOLNS")
#! Field("MGNT:LTUS:1:ALLSOLNS.VAL",16777215,0,"MGNT:LTUS:1:ALLSOLNS.VAL")
#! Field("MGNT:LTUS:1:ALLSOLNS.FLNK",16777215,1,"MGNT:LTUS:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:LTUS:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:LTUS:1:KICKSWITCH")
}

record(seq, "MGNT:LTUS:1:KICKSWITCH") {
  field(DOL1, "MGNT:LTUS:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:LTUS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUS:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUS:1:KICKCTRL")
}

record(seq, "MGNT:LTUS:1:ALLKICKSGO") {
  field(DOL1, "MGNT:LTUS:1:ALLSTAR")
  field(LNK1, "MGNT:LTUS:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:LTUS:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUS:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUS:1:KICKCTRL",20,10,0,0,"MGNT:LTUS:1:KICKCTRL")
#! Field("MGNT:LTUS:1:KICKCTRL.FLNK",16777215,1,"MGNT:LTUS:1:KICKCTRL.FLNK")
#! Link("MGNT:LTUS:1:KICKCTRL.FLNK","MGNT:LTUS:1:KICKSWITCH")
#! Field("MGNT:LTUS:1:KICKCTRL.FFVL",16777215,1,"MGNT:LTUS:1:KICKCTRL.FFVL")
#! Record("MGNT:LTUS:1:KICKSWITCH",460,322,0,0,"MGNT:LTUS:1:KICKSWITCH")
#! Field("MGNT:LTUS:1:KICKSWITCH.DOL1",16777215,0,"MGNT:LTUS:1:KICKSWITCH.DOL1")
#! Link("MGNT:LTUS:1:KICKSWITCH.DOL1","MGNT:LTUS:1:KICKCTRL.FFVL")
#! Field("MGNT:LTUS:1:KICKSWITCH.LNK1",16777215,1,"MGNT:LTUS:1:KICKSWITCH.LNK1")
#! Field("MGNT:LTUS:1:KICKSWITCH.FLNK",16777215,1,"MGNT:LTUS:1:KICKSWITCH.FLNK")
#! Record("MGNT:LTUS:1:ALLKICKSGO",240,96,0,0,"MGNT:LTUS:1:ALLKICKSGO")
#! Field("MGNT:LTUS:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:LTUS:1:ALLKICKSGO.DOL1")
#! Field("MGNT:LTUS:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:LTUS:1:ALLKICKSGO.LNK1")
#! Link("MGNT:LTUS:1:ALLKICKSGO.LNK1","MGNT:LTUS:1:ALLKICKS.VAL")
#! Record("MGNT:LTUS:1:ALLKICKS",540,102,0,0,"MGNT:LTUS:1:ALLKICKS")
#! Field("MGNT:LTUS:1:ALLKICKS.VAL",16777215,0,"MGNT:LTUS:1:ALLKICKS.VAL")
#! Field("MGNT:LTUS:1:ALLKICKS.FLNK",16777215,1,"MGNT:LTUS:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:LTUS:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:LTUS:1:SEXTSWITCH")
}

record(seq, "MGNT:LTUS:1:SEXTSWITCH") {
  field(DOL1, "MGNT:LTUS:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:LTUS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:LTUS:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:LTUS:1:SEXTCTRL")
}

record(seq, "MGNT:LTUS:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:LTUS:1:ALLSTAR")
  field(LNK1, "MGNT:LTUS:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:LTUS:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:LTUS:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:LTUS:1:SEXTCTRL",20,10,0,0,"MGNT:LTUS:1:SEXTCTRL")
#! Field("MGNT:LTUS:1:SEXTCTRL.FLNK",16777215,1,"MGNT:LTUS:1:SEXTCTRL.FLNK")
#! Link("MGNT:LTUS:1:SEXTCTRL.FLNK","MGNT:LTUS:1:SEXTSWITCH")
#! Field("MGNT:LTUS:1:SEXTCTRL.FFVL",16777215,1,"MGNT:LTUS:1:SEXTCTRL.FFVL")
#! Record("MGNT:LTUS:1:SEXTSWITCH",460,322,0,0,"MGNT:LTUS:1:SEXTSWITCH")
#! Field("MGNT:LTUS:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:LTUS:1:SEXTSWITCH.DOL1")
#! Link("MGNT:LTUS:1:SEXTSWITCH.DOL1","MGNT:LTUS:1:SEXTCTRL.FFVL")
#! Field("MGNT:LTUS:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:LTUS:1:SEXTSWITCH.LNK1")
#! Field("MGNT:LTUS:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:LTUS:1:SEXTSWITCH.FLNK")
#! Record("MGNT:LTUS:1:ALLSEXTSGO",240,96,0,0,"MGNT:LTUS:1:ALLSEXTSGO")
#! Field("MGNT:LTUS:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:LTUS:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:LTUS:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:LTUS:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:LTUS:1:ALLSEXTSGO.LNK1","MGNT:LTUS:1:ALLSEXTS.VAL")
#! Record("MGNT:LTUS:1:ALLSEXTS",540,102,0,0,"MGNT:LTUS:1:ALLSEXTS")
#! Field("MGNT:LTUS:1:ALLSEXTS.VAL",16777215,0,"MGNT:LTUS:1:ALLSEXTS.VAL")
#! Field("MGNT:LTUS:1:ALLSEXTS.FLNK",16777215,1,"MGNT:LTUS:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBDEND


record(seq, "MGNT:LTUH:1:ALLSOLNSSEL") {
}
record(seq, "MGNT:LTUH:1:ALLKICKSSEL") {
  field(DOL1, "MGNT:LTUH:1:ALLKICKS")
  field(LNK1, "KICK:LTUH:320:SELECT CPP NMS")
}
record(seq, "MGNT:LTUH:1:ALLSEXTSSEL") {
}



record(seq, "MGNT:LTUH:1:ALLBENDSSEL") {
  field(DOL1, "MGNT:LTUH:1:ALLBENDS")
  field(DOL2, "MGNT:LTUH:1:ALLBENDS")
  field(DOL3, "MGNT:LTUH:1:ALLBENDS")
  field(DOL4, "MGNT:LTUH:1:ALLBENDS")
  field(LNK1, "BEND:LTUH:125:SELECT CPP NMS")
  field(LNK2, "BEND:LTUH:301:SELECT CPP NMS")
  field(LNK3, "BEND:LTUH:376:SELECT CPP NMS")
  field(LNK4, "BEND:LTUH:506:SELECT CPP NMS")
}

record(seq, "MGNT:LTUH:1:ALLBTRMSSEL") {
  field(DOL1, "MGNT:LTUH:1:ALLBTRMS")
  field(DOL2, "MGNT:LTUH:1:ALLBTRMS")
  field(DOL3, "MGNT:LTUH:1:ALLBTRMS")
  field(DOL4, "MGNT:LTUH:1:ALLBTRMS")
  field(DOL5, "MGNT:LTUH:1:ALLBTRMS")
  field(DOL6, "MGNT:LTUH:1:ALLBTRMS")
  field(DOL7, "MGNT:LTUH:1:ALLBTRMS")
  field(DOL8, "MGNT:LTUH:1:ALLBTRMS")
  field(DOL9, "MGNT:LTUH:1:ALLBTRMS")
  field(DOLA, "MGNT:LTUH:1:ALLBTRMS")
  field(LNK1, "BTRM:LTUH:220:SELECT CPP NMS")
  field(LNK2, "BTRM:LTUH:280:SELECT CPP NMS")
  field(LNK3, "BTRM:LTUH:300:SELECT CPP NMS")
  field(LNK4, "BTRM:LTUH:302:SELECT CPP NMS")
  field(LNK5, "BTRM:LTUH:303:SELECT CPP NMS")
  field(LNK6, "BTRM:LTUH:375:SELECT CPP NMS")
  field(LNK7, "BTRM:LTUH:377:SELECT CPP NMS")
  field(LNK8, "BTRM:LTUH:378:SELECT CPP NMS")
  field(LNK9, "BTRM:LTUH:420:SELECT CPP NMS")
  field(LNKA, "BTRM:LTUH:480:SELECT CPP NMS")
  field(FLNK, "MGNT:LTUH:1:ALLBTRMSSEL_2")
}

record(seq, "MGNT:LTUH:1:ALLBTRMSSEL_2") {
  field(DOL1, "MGNT:LTUH:1:ALLBTRMS")
  field(DOL2, "MGNT:LTUH:1:ALLBTRMS")
  field(DOL3, "MGNT:LTUH:1:ALLBTRMS")
  field(DOL3, "MGNT:LTUH:1:ALLBTRMS")
  field(LNK1, "BTRM:LTUH:505:SELECT CPP NMS")
  field(LNK3, "BTRM:LTUH:507:SELECT CPP NMS")
  field(LNK4, "BTRM:LTUH:508:SELECT CPP NMS")
}

record(seq, "MGNT:LTUH:1:ALLLGPSSSEL") {
  field(DOL1, "MGNT:LTUH:1:ALLLGPSS")
  field(DOL2, "MGNT:LTUH:1:ALLLGPSS")
  field(DOL3, "MGNT:LTUH:1:ALLLGPSS")
  field(DOL4, "MGNT:LTUH:1:ALLLGPSS")
  field(DOL5, "MGNT:LTUH:1:ALLLGPSS")
  field(DOL6, "MGNT:LTUH:1:ALLLGPSS")
  field(LNK1, "LGPS:LTUH:1:SELECT CPP NMS")
  field(LNK2, "LGPS:LTUH:1:SELECT CPP NMS")
  field(LNK3, "LGPS:LTUH:2:SELECT CPP NMS")
  field(LNK4, "LGPS:LTUH:3:SELECT CPP NMS")
  field(LNK5, "LGPS:LTUH:4:SELECT CPP NMS")
  field(LNK6, "LGPS:LTUH:5:SELECT CPP NMS")
}

record(seq, "MGNT:LTUH:1:ALLQUADSSEL") {
  field(DOL1, "MGNT:LTUH:1:ALLQUADS")
  field(DOL2, "MGNT:LTUH:1:ALLQUADS")
  field(DOL3, "MGNT:LTUH:1:ALLQUADS")
  field(DOL4, "MGNT:LTUH:1:ALLQUADS")
  field(DOL5, "MGNT:LTUH:1:ALLQUADS")
  field(LNK1, "QUAD:LTUH:110:SELECT CPP NMS")
  field(LNK2, "QUAD:LTUH:120:SELECT CPP NMS")
  field(LNK3, "QUAD:LTUH:130:SELECT CPP NMS")
  field(LNK4, "QUAD:LTUH:180:SELECT CPP NMS")
  field(LNK5, "QUAD:LTUH:190:SELECT CPP NMS")
  field(FLNK, "MGNT:LTUH:1:ALLQUADSSEL_2.PROC")
}
record(seq, "MGNT:LTUH:1:ALLQUADSSEL_2") {
  field(DOL1, "MGNT:LTUH:1:ALLQUADS")
  field(DOL2, "MGNT:LTUH:1:ALLQUADS")
  field(DOL3, "MGNT:LTUH:1:ALLQUADS")
  field(DOL4, "MGNT:LTUH:1:ALLQUADS")
  field(DOL5, "MGNT:LTUH:1:ALLQUADS")
  field(DOL6, "MGNT:LTUH:1:ALLQUADS")
  field(DOL7, "MGNT:LTUH:1:ALLQUADS")
  field(DOL8, "MGNT:LTUH:1:ALLQUADS")
  field(DOL9, "MGNT:LTUH:1:ALLQUADS")
  field(DOLA, "MGNT:LTUH:1:ALLQUADS")
  field(LNK1, "QUAD:LTUH:250:SELECT CPP NMS")
  field(LNK2, "QUAD:LTUH:285:SELECT CPP NMS")
  field(LNK3, "QUAD:LTUH:290:SELECT CPP NMS")
  field(LNK4, "QUAD:LTUH:440:SELECT CPP NMS")
  field(LNK5, "QUAD:LTUH:460:SELECT CPP NMS")
  field(LNK6, "QUAD:LTUH:620:SELECT CPP NMS")
  field(LNK7, "QUAD:LTUH:640:SELECT CPP NMS")
  field(LNK8, "QUAD:LTUH:660:SELECT CPP NMS")
  field(LNK9, "QUAD:LTUH:665:SELECT CPP NMS")
  field(LNKA, "QUAD:LTUH:680:SELECT CPP NMS")
  field(FLNK, "MGNT:LTUH:1:ALLQUADSSEL_3.PROC")
}
record(seq, "MGNT:LTUH:1:ALLQUADSSEL_3") {
  field(DOL1, "MGNT:LTUH:1:ALLQUADS")
  field(DOL2, "MGNT:LTUH:1:ALLQUADS")
  field(DOL3, "MGNT:LTUH:1:ALLQUADS")
  field(DOL4, "MGNT:LTUH:1:ALLQUADS")
  field(DOL5, "MGNT:LTUH:1:ALLQUADS")
  field(LNK1, "QUAD:LTUH:720:SELECT CPP NMS")
  field(LNK2, "QUAD:LTUH:820:SELECT CPP NMS")
  field(LNK3, "QUAD:LTUH:840:SELECT CPP NMS")
  field(LNK4, "QUAD:LTUH:860:SELECT CPP NMS")
  field(LNK5, "QUAD:LTUH:880:SELECT CPP NMS")
}

record(seq, "MGNT:LTUH:1:ALLXCORSSEL") {
  field(DOL1, "MGNT:LTUH:1:ALLXCORS")
  field(DOL2, "MGNT:LTUH:1:ALLXCORS")
  field(DOL3, "MGNT:LTUH:1:ALLXCORS")
  field(DOL4, "MGNT:LTUH:1:ALLXCORS")
  field(DOL5, "MGNT:LTUH:1:ALLXCORS")
  field(DOL6, "MGNT:LTUH:1:ALLXCORS")
  field(LNK1, "XCOR:LTUH:115:SELECT CPP NMS")
  field(LNK2, "XCOR:LTUH:178:SELECT CPP NMS")
  field(LNK3, "XCOR:LTUH:248:SELECT CPP NMS")
  field(LNK4, "XCOR:LTUH:348:SELECT CPP NMS")
  field(LNK5, "XCOR:LTUH:448:SELECT CPP NMS")
  field(LNK6, "XCOR:LTUH:558:SELECT CPP NMS")
  field(FLNK, "MGNT:LTUH:1:ALLXCORSSEL_2.PROC")
}

record(seq, "MGNT:LTUH:1:ALLXCORSSEL_2") {
  field(DOL1, "MGNT:LTUH:1:ALLXCORS")
  field(DOL2, "MGNT:LTUH:1:ALLXCORS")
  field(DOL3, "MGNT:LTUH:1:ALLXCORS")
  field(DOL4, "MGNT:LTUH:1:ALLXCORS")
  field(DOL5, "MGNT:LTUH:1:ALLXCORS")
  field(DOL6, "MGNT:LTUH:1:ALLXCORS")
  field(LNK1, "XCOR:LTUH:288:SELECT CPP NMS")
  field(LNK2, "XCOR:LTUH:388:SELECT CPP NMS")
  field(LNK3, "XCOR:LTUH:488:SELECT CPP NMS")
  field(LNK4, "XCOR:LTUH:588:SELECT CPP NMS")
  field(LNK5, "XCOR:LTUH:642:SELECT CPP NMS")
  field(LNK6, "XCOR:LTUH:678:SELECT CPP NMS")
  field(FLNK, "MGNT:LTUH:1:ALLXCORSSEL_3.PROC")
}
record(seq, "MGNT:LTUH:1:ALLXCORSSEL_3") {
  field(DOL1, "MGNT:LTUH:1:ALLXCORS")
  field(DOL2, "MGNT:LTUH:1:ALLXCORS")
  field(DOL3, "MGNT:LTUH:1:ALLXCORS")
  field(DOL4, "MGNT:LTUH:1:ALLXCORS")
  field(DOL5, "MGNT:LTUH:1:ALLXCORS")
  field(DOL6, "MGNT:LTUH:1:ALLXCORS")
  field(LNK1, "XCOR:LTUH:718:SELECT CPP NMS")
  field(LNK2, "XCOR:LTUH:738:SELECT CPP NMS")
  field(LNK3, "XCOR:LTUH:758:SELECT CPP NMS")
  field(LNK4, "XCOR:LTUH:818:SELECT CPP NMS")
  field(LNK5, "XCOR:LTUH:858:SELECT CPP NMS")
  field(LNK6, "XCOR:LTUH:144:SELECT CPP NMS")
}

record(seq, "MGNT:LTUH:1:ALLYCORSSEL") {
  field(DOL1, "MGNT:LTUH:1:ALLYCORS")
  field(DOL2, "MGNT:LTUH:1:ALLYCORS")
  field(DOL3, "MGNT:LTUH:1:ALLYCORS")
  field(DOL4, "MGNT:LTUH:1:ALLYCORS")
  field(LNK1, "YCOR:LTUH:105:SELECT CPP NMS")
  field(LNK2, "YCOR:LTUH:133:SELECT CPP NMS")
  field(LNK3, "YCOR:LTUH:171:SELECT CPP NMS")
  field(LNK4, "YCOR:LTUH:185:SELECT CPP NMS")
  field(FLNK, "MGNT:LTUH:1:ALLYCORSSEL_2.PROC")
}
record(seq, "MGNT:LTUH:1:ALLYCORSSEL_2") {
  field(DOL1, "MGNT:LTUH:1:ALLYCORS")
  field(DOL2, "MGNT:LTUH:1:ALLYCORS")
  field(DOL3, "MGNT:LTUH:1:ALLYCORS")
  field(DOL4, "MGNT:LTUH:1:ALLYCORS")
  field(DOL5, "MGNT:LTUH:1:ALLYCORS")
  field(DOL6, "MGNT:LTUH:1:ALLYCORS")
  field(DOL7, "MGNT:LTUH:1:ALLYCORS")
  field(DOL8, "MGNT:LTUH:1:ALLYCORS")
  field(DOL9, "MGNT:LTUH:1:ALLYCORS")
  field(LNK1, "YCOR:LTUH:253:SELECT CPP NMS")
  field(LNK2, "YCOR:LTUH:353:SELECT CPP NMS")
  field(LNK3, "YCOR:LTUH:383:SELECT CPP NMS")
  field(LNK4, "YCOR:LTUH:453:SELECT CPP NMS")
  field(LNK5, "YCOR:LTUH:493:SELECT CPP NMS")
  field(LNK6, "YCOR:LTUH:563:SELECT CPP NMS")
  field(LNK7, "YCOR:LTUH:593:SELECT CPP NMS")
  field(LNK8, "YCOR:LTUH:611:SELECT CPP NMS")
  field(LNK9, "YCOR:LTUH:657:SELECT CPP NMS")
  field(FLNK, "MGNT:LTUH:1:ALLYCORSSEL_3.PROC")
}
record(seq, "MGNT:LTUH:1:ALLYCORSSEL_3") {
  field(DOL1, "MGNT:LTUH:1:ALLYCORS")
  field(DOL2, "MGNT:LTUH:1:ALLYCORS")
  field(DOL3, "MGNT:LTUH:1:ALLYCORS")
  field(DOL4, "MGNT:LTUH:1:ALLYCORS")
  field(DOL5, "MGNT:LTUH:1:ALLYCORS")
  field(LNK1, "YCOR:LTUH:727:SELECT CPP NMS")
  field(LNK2, "YCOR:LTUH:747:SELECT CPP NMS")
  field(LNK3, "YCOR:LTUH:767:SELECT CPP NMS")
  field(LNK4, "YCOR:LTUH:837:SELECT CPP NMS")
  field(LNK5, "YCOR:LTUH:877:SELECT CPP NMS")
}

record(seq, "MGNT:LTUH:1:ALLFUNCGO") {
  field(DESC, "Process CTRL func0")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(LNK1, "MGNT:LTUH:1:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:LTUH:1:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:LTUH:1:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:LTUH:1:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:LTUH:1:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:LTUH:1:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:LTUH:1:LGPSFUNCGO.PROC")
  field(FLNK, "MGNT:LTUH:1:ALLFUNCGO2")
}
record(seq, "MGNT:LTUH:1:ALLFUNCGO2") {
  field(DESC, "Process CTRL func0")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:LTUH:1:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:LTUH:1:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:LTUH:1:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:LTUH:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:LTUH:1:CTRLCLEAR")
}

record(fanout, "MGNT:LTUH:1:SOLNFUNCGO") {
  field(DESC, "Process All SOLNs")
  field(FLNK, "MGNT:LTUH:1:CTRLCLEAR")
}
record(fanout, "MGNT:LTUH:1:KICKFUNCGO") {
  field(DESC, "Process All KICKs")
  field(LNK1, "KICK:LTUH:320:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:CTRLCLEAR")
}
record(fanout, "MGNT:LTUH:1:SEXTFUNCGO") {
  field(DESC, "Process All SEXTs")
  field(FLNK, "MGNT:LTUH:1:CTRLCLEAR")
}


record(fanout, "MGNT:LTUH:1:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(LNK1, "BEND:LTUH:125:ALLFUNCGO")
  field(LNK2, "BEND:LTUH:301:ALLFUNCGO")
  field(LNK3, "BEND:LTUH:376:ALLFUNCGO")
  field(LNK4, "BEND:LTUH:506:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:CTRLCLEAR")
}

record(fanout, "MGNT:LTUH:1:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(LNK1, "BTRM:LTUH:220:ALLFUNCGO")
  field(LNK2, "BTRM:LTUH:280:ALLFUNCGO")
  field(LNK3, "BTRM:LTUH:300:ALLFUNCGO")
  field(LNK4, "BTRM:LTUH:302:ALLFUNCGO")
  field(LNK5, "BTRM:LTUH:303:ALLFUNCGO")
  field(LNK6, "BTRM:LTUH:375:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:BTRMFUNCGO_2")
}

record(fanout, "MGNT:LTUH:1:BTRMFUNCGO_2") {
  field(DESC, "Process BTRM CTRL func")
  field(LNK1, "BTRM:LTUH:377:ALLFUNCGO")
  field(LNK2, "BTRM:LTUH:378:ALLFUNCGO")
  field(LNK3, "BTRM:LTUH:420:ALLFUNCGO")
  field(LNK4, "BTRM:LTUH:480:ALLFUNCGO")
  field(LNK5, "BTRM:LTUH:505:ALLFUNCGO")
  field(LNK6, "BTRM:LTUH:507:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:BTRMFUNCGO_3")
}

record(fanout, "MGNT:LTUH:1:BTRMFUNCGO_3") {
  field(DESC, "Process BTRM CTRL func")
  field(LNK1, "BTRM:LTUH:508:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:CTRLCLEAR")
}

record(fanout, "MGNT:LTUH:1:QUADFUNCGO") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:LTUH:110:ALLFUNCGO")
  field(LNK2, "QUAD:LTUH:120:ALLFUNCGO")
  field(LNK3, "QUAD:LTUH:130:ALLFUNCGO")
  field(LNK4, "QUAD:LTUH:180:ALLFUNCGO")
  field(LNK5, "QUAD:LTUH:190:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:QUADFUNCGO_2")
}
record(fanout, "MGNT:LTUH:1:QUADFUNCGO_2") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:LTUH:250:ALLFUNCGO")
  field(LNK2, "QUAD:LTUH:285:ALLFUNCGO")
  field(LNK3, "QUAD:LTUH:290:ALLFUNCGO")
  field(LNK4, "QUAD:LTUH:440:ALLFUNCGO")
  field(LNK5, "QUAD:LTUH:460:ALLFUNCGO")
  field(LNK5, "QUAD:LTUH:620:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:QUADFUNCGO_3")
}
record(fanout, "MGNT:LTUH:1:QUADFUNCGO_3") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:LTUH:640:ALLFUNCGO")
  field(LNK2, "QUAD:LTUH:660:ALLFUNCGO")
  field(LNK3, "QUAD:LTUH:665:ALLFUNCGO")
  field(LNK4, "QUAD:LTUH:680:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:QUADFUNCGO_4")
}
record(fanout, "MGNT:LTUH:1:QUADFUNCGO_4") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:LTUH:720:ALLFUNCGO")
  field(LNK2, "QUAD:LTUH:820:ALLFUNCGO")
  field(LNK3, "QUAD:LTUH:840:ALLFUNCGO")
  field(LNK4, "QUAD:LTUH:860:ALLFUNCGO")
  field(LNK5, "QUAD:LTUH:880:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:CTRLCLEAR")
}

record(fanout, "MGNT:LTUH:1:XCORFUNCGO") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:LTUH:115:ALLFUNCGO")
  field(LNK2, "XCOR:LTUH:178:ALLFUNCGO")
  field(LNK3, "XCOR:LTUH:248:ALLFUNCGO")
  field(LNK4, "XCOR:LTUH:348:ALLFUNCGO")
  field(LNK5, "XCOR:LTUH:448:ALLFUNCGO")
  field(LNK6, "XCOR:LTUH:558:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:XCORFUNCGO_2")
}
record(fanout, "MGNT:LTUH:1:XCORFUNCGO_2") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:LTUH:288:ALLFUNCGO")
  field(LNK2, "XCOR:LTUH:388:ALLFUNCGO")
  field(LNK3, "XCOR:LTUH:488:ALLFUNCGO")
  field(LNK4, "XCOR:LTUH:588:ALLFUNCGO")
  field(LNK5, "XCOR:LTUH:642:ALLFUNCGO")
  field(LNK6, "XCOR:LTUH:678:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:XCORFUNCGO_3")
}
record(fanout, "MGNT:LTUH:1:XCORFUNCGO_3") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:LTUH:144:ALLFUNCGO")
  field(LNK2, "XCOR:LTUH:718:ALLFUNCGO")
  field(LNK3, "XCOR:LTUH:738:ALLFUNCGO")
  field(LNK4, "XCOR:LTUH:758:ALLFUNCGO")
  field(LNK5, "XCOR:LTUH:818:ALLFUNCGO")
  field(LNK6, "XCOR:LTUH:858:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:CTRLCLEAR")
}

record(fanout, "MGNT:LTUH:1:YCORFUNCGO") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:LTUH:105:ALLFUNCGO")
  field(LNK2, "YCOR:LTUH:133:ALLFUNCGO")
  field(LNK3, "YCOR:LTUH:171:ALLFUNCGO")
  field(LNK4, "YCOR:LTUH:185:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:YCORFUNCGO_2")
}
record(fanout, "MGNT:LTUH:1:YCORFUNCGO_2") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:LTUH:253:ALLFUNCGO")
  field(LNK2, "YCOR:LTUH:293:ALLFUNCGO")
  field(LNK3, "YCOR:LTUH:353:ALLFUNCGO")
  field(LNK4, "YCOR:LTUH:383:ALLFUNCGO")
  field(LNK5, "YCOR:LTUH:453:ALLFUNCGO")
  field(LNK6, "YCOR:LTUH:493:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:YCORFUNCGO_3")
}
record(fanout, "MGNT:LTUH:1:YCORFUNCGO_3") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:LTUH:563:ALLFUNCGO")
  field(LNK2, "YCOR:LTUH:593:ALLFUNCGO")
  field(LNK3, "YCOR:LTUH:611:ALLFUNCGO")
  field(LNK4, "YCOR:LTUH:657:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:YCORFUNCGO_4")
}
record(fanout, "MGNT:LTUH:1:YCORFUNCGO_4") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:LTUH:727:ALLFUNCGO")
  field(LNK2, "YCOR:LTUH:747:ALLFUNCGO")
  field(LNK3, "YCOR:LTUH:767:ALLFUNCGO")
  field(LNK4, "YCOR:LTUH:837:ALLFUNCGO")
  field(LNK5, "YCOR:LTUH:877:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:CTRLCLEAR")
}

record(fanout, "MGNT:LTUH:1:LGPSFUNCGO") {
  field(DESC, "Process LGPS CTRL func")
  field(LNK1, "LGPS:LTUH:1:ALLFUNCGO")
  field(LNK2, "LGPS:LTUH:1:ALLFUNCGO")
  field(LNK3, "LGPS:LTUH:2:ALLFUNCGO")
  field(LNK4, "LGPS:LTUH:3:ALLFUNCGO")
  field(LNK5, "LGPS:LTUH:4:ALLFUNCGO")
  field(LNK6, "LGPS:LTUH:5:ALLFUNCGO")
  field(FLNK, "MGNT:LTUH:1:CTRLCLEAR")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBDEND


record(seq, "MGNT:LTUS:1:ALLSOLNSSEL") {
}
record(seq, "MGNT:LTUS:1:ALLKICKSSEL") {
  field(DOL1, "MGNT:LTUS:1:ALLKICKS")
  field(LNK1, "KICK:LTUS:350:SELECT CPP NMS")
}
record(seq, "MGNT:LTUS:1:ALLSEXTSSEL") {
}

record(seq, "MGNT:LTUS:1:ALLBENDSSEL") {
  field(DOL1, "MGNT:LTUS:1:ALLBENDS")
  field(DOL2, "MGNT:LTUS:1:ALLBENDS")
  field(DOL3, "MGNT:LTUS:1:ALLBENDS")
  field(DOL4, "MGNT:LTUS:1:ALLBENDS")
  field(DOL5, "MGNT:LTUS:1:ALLBENDS")
  field(LNK1, "BEND:LTUS:166:SELECT CPP NMS")
  field(LNK2, "BEND:DMPS:400:SELECT CPP NMS")
  field(LNK3, "BEND:LTUS:476:SELECT CPP NMS")
  field(LNK4, "BEND:LTUS:525:SELECT CPP NMS")
  field(LNK5, "BEND:LTUS:764:SELECT CPP NMS")
}

record(seq, "MGNT:LTUS:1:ALLBTRMSSEL") {
  field(DOL1, "MGNT:LTUS:1:ALLBTRMS")
  field(DOL2, "MGNT:LTUS:1:ALLBTRMS")
  field(DOL3, "MGNT:LTUS:1:ALLBTRMS")
  field(DOL4, "MGNT:LTUS:1:ALLBTRMS")
  field(DOL5, "MGNT:LTUS:1:ALLBTRMS")
  field(DOL6, "MGNT:LTUS:1:ALLBTRMS")
  field(DOL7, "MGNT:LTUS:1:ALLBTRMS")
  field(DOL8, "MGNT:LTUS:1:ALLBTRMS")
  field(LNK1, "BTRM:LTUS:165:SELECT CPP NMS")
  field(LNK2, "BTRM:LTUS:167:SELECT CPP NMS")
  field(LNK3, "BTRM:LTUS:168:SELECT CPP NMS")
  field(LNK4, "BTRM:LTUS:175:SELECT CPP NMS")
  field(LNK5, "BTRM:LTUS:460:SELECT CPP NMS")
  field(LNK6, "BTRM:LTUS:475:SELECT CPP NMS")
  field(LNK7, "BTRM:LTUS:477:SELECT CPP NMS")
  field(LNK8, "BTRM:LTUS:478:SELECT CPP NMS")
  field(FLNK, "MGNT:LTUS:1:ALLBTRMSSEL_2")
}

record(seq, "MGNT:LTUS:1:ALLBTRMSSEL_2") {
  field(DOL1, "MGNT:LTUS:1:ALLBTRMS")
  field(DOL2, "MGNT:LTUS:1:ALLBTRMS")
  field(DOL3, "MGNT:LTUS:1:ALLBTRMS")
  field(LNK1, "BTRM:LTUS:763:SELECT CPP NMS")
  field(LNK2, "BTRM:LTUS:765:SELECT CPP NMS")
  field(LNK3, "BTRM:LTUS:766:SELECT CPP NMS")
}

record(seq, "MGNT:LTUS:1:ALLLGPSSSEL") {
  field(DOL1, "MGNT:LTUS:1:ALLLGPSS")
  field(DOL2, "MGNT:LTUS:1:ALLLGPSS")
  field(DOL3, "MGNT:LTUS:1:ALLLGPSS")
  field(DOL4, "MGNT:LTUS:1:ALLLGPSS")
  field(DOL5, "MGNT:LTUS:1:ALLLGPSS")
  field(DOL6, "MGNT:LTUS:1:ALLLGPSS")
  field(DOL7, "MGNT:LTUS:1:ALLLGPSS")
  field(DOL8, "MGNT:LTUS:1:ALLLGPSS")
  field(LNK1, "LGPS:LTUS:1:SELECT CPP NMS")
  field(LNK2, "LGPS:LTUS:1:SELECT CPP NMS")
  field(LNK3, "LGPS:LTUS:2:SELECT CPP NMS")
  field(LNK4, "LGPS:LTUS:3:SELECT CPP NMS")
  field(LNK5, "LGPS:LTUS:4:SELECT CPP NMS")
  field(LNK6, "LGPS:LTUS:5:SELECT CPP NMS")
  field(LNK7, "LGPS:LTUS:6:SELECT CPP NMS")
  field(LNK8, "LGPS:LTUS:7:SELECT CPP NMS")
}

record(seq, "MGNT:LTUS:1:ALLQUADSSEL") {
  field(DOL1, "MGNT:LTUS:1:ALLQUADS")
  field(DOL2, "MGNT:LTUS:1:ALLQUADS")
  field(DOL3, "MGNT:LTUS:1:ALLQUADS")
  field(DOL4, "MGNT:LTUS:1:ALLQUADS")
  field(DOL5, "MGNT:LTUS:1:ALLQUADS")
  field(DOL6, "MGNT:LTUS:1:ALLQUADS")
  field(DOL7, "MGNT:LTUS:1:ALLQUADS")
  field(DOL8, "MGNT:LTUS:1:ALLQUADS")
  field(DOL9, "MGNT:LTUS:1:ALLQUADS")
  field(DOLA, "MGNT:LTUS:1:ALLQUADS")
  field(LNK1, "QUAD:LTUS:110:SELECT CPP NMS")
  field(LNK2, "QUAD:LTUS:120:SELECT CPP NMS")
  field(LNK3, "QUAD:LTUS:150:SELECT CPP NMS")
  field(LNK4, "QUAD:LTUS:180:SELECT CPP NMS")
  field(LNK5, "QUAD:LTUS:235:SELECT CPP NMS")
  field(LNK6, "QUAD:LTUS:470:SELECT CPP NMS")
  field(LNK7, "QUAD:LTUS:500:SELECT CPP NMS")
  field(LNK8, "QUAD:LTUS:510:SELECT CPP NMS")
  field(LNK9, "QUAD:LTUS:540:SELECT CPP NMS")
  field(LNKA, "QUAD:LTUS:570:SELECT CPP NMS")
  field(FLNK, "MGNT:LTUS:1:ALLQUADSSEL_2.PROC")
}
record(seq, "MGNT:LTUS:1:ALLQUADSSEL_2") {
  field(DOL1, "MGNT:LTUS:1:ALLQUADS")
  field(DOL2, "MGNT:LTUS:1:ALLQUADS")
  field(DOL3, "MGNT:LTUS:1:ALLQUADS")
  field(DOL4, "MGNT:LTUS:1:ALLQUADS")
  field(DOL5, "MGNT:LTUS:1:ALLQUADS")
  field(DOL6, "MGNT:LTUS:1:ALLQUADS")
  field(DOL7, "MGNT:LTUS:1:ALLQUADS")
  field(DOL8, "MGNT:LTUS:1:ALLQUADS")
  field(DOL9, "MGNT:LTUS:1:ALLQUADS")
  field(LNK1, "QUAD:LTUS:580:SELECT CPP NMS")
  field(LNK2, "QUAD:LTUS:620:SELECT CPP NMS")
  field(LNK3, "QUAD:LTUS:640:SELECT CPP NMS")
  field(LNK4, "QUAD:LTUS:660:SELECT CPP NMS")
  field(LNK5, "QUAD:LTUS:665:SELECT CPP NMS")
  field(LNK6, "QUAD:LTUS:680:SELECT CPP NMS")
  field(LNK7, "QUAD:LTUS:720:SELECT CPP NMS")
  field(LNK8, "QUAD:LTUS:725:SELECT CPP NMS")
  field(LNK9, "QUAD:LTUS:730:SELECT CPP NMS")
  field(FLNK, "MGNT:LTUS:1:ALLQUADSSEL_3.PROC")
}
record(seq, "MGNT:LTUS:1:ALLQUADSSEL_3") {
  field(DOL1, "MGNT:LTUS:1:ALLQUADS")
  field(DOL2, "MGNT:LTUS:1:ALLQUADS")
  field(DOL3, "MGNT:LTUS:1:ALLQUADS")
  field(DOL4, "MGNT:LTUS:1:ALLQUADS")
  field(DOL5, "MGNT:LTUS:1:ALLQUADS")
  field(DOL6, "MGNT:LTUS:1:ALLQUADS")
  field(DOL7, "MGNT:LTUS:1:ALLQUADS")
  field(DOL8, "MGNT:LTUS:1:ALLQUADS")
  field(DOL9, "MGNT:LTUS:1:ALLQUADS")
  field(LNK1, "QUAD:LTUS:740:SELECT CPP NMS")
  field(LNK2, "QUAD:LTUS:750:SELECT CPP NMS")
  field(LNK3, "QUAD:LTUS:760:SELECT CPP NMS")
  field(LNK4, "QUAD:LTUS:772:SELECT CPP NMS")
  field(LNK5, "QUAD:LTUS:780:SELECT CPP NMS")
  field(LNK6, "QUAD:LTUS:820:SELECT CPP NMS")
  field(LNK7, "QUAD:LTUS:840:SELECT CPP NMS")
  field(LNK8, "QUAD:LTUS:860:SELECT CPP NMS")
  field(LNK9, "QUAD:LTUS:880:SELECT CPP NMS")
}

record(seq, "MGNT:LTUS:1:ALLXCORSSEL") {
  field(DOL1, "MGNT:LTUS:1:ALLXCORS")
  field(DOL2, "MGNT:LTUS:1:ALLXCORS")
  field(DOL3, "MGNT:LTUS:1:ALLXCORS")
  field(DOL4, "MGNT:LTUS:1:ALLXCORS")
  field(DOL5, "MGNT:LTUS:1:ALLXCORS")
  field(DOL6, "MGNT:LTUS:1:ALLXCORS")
  field(LNK1, "XCOR:LTUS:118:SELECT CPP NMS")
  field(LNK2, "XCOR:LTUS:148:SELECT CPP NMS")
  field(LNK3, "XCOR:LTUS:228:SELECT CPP NMS")
  field(LNK4, "XCOR:LTUS:296:SELECT CPP NMS")
  field(LNK5, "XCOR:LTUS:368:SELECT CPP NMS")
  field(LNK6, "XCOR:LTUS:448:SELECT CPP NMS")
  field(FLNK, "MGNT:LTUS:1:ALLXCORSSEL_2.PROC")
}

record(seq, "MGNT:LTUS:1:ALLXCORSSEL_2") {
  field(DOL1, "MGNT:LTUS:1:ALLXCORS")
  field(DOL2, "MGNT:LTUS:1:ALLXCORS")
  field(DOL3, "MGNT:LTUS:1:ALLXCORS")
  field(DOL4, "MGNT:LTUS:1:ALLXCORS")
  field(DOL5, "MGNT:LTUS:1:ALLXCORS")
  field(DOL6, "MGNT:LTUS:1:ALLXCORS")
  field(LNK1, "XCOR:LTUS:508:SELECT CPP NMS")
  field(LNK2, "XCOR:LTUS:548:SELECT CPP NMS")
  field(LNK3, "XCOR:LTUS:568:SELECT CPP NMS")
  field(LNK4, "XCOR:LTUS:616:SELECT CPP NMS")
  field(LNK5, "XCOR:LTUS:658:SELECT CPP NMS")
  field(LNK6, "XCOR:LTUS:718:SELECT CPP NMS")
  field(FLNK, "MGNT:LTUS:1:ALLXCORSSEL_3.PROC")
}
record(seq, "MGNT:LTUS:1:ALLXCORSSEL_3") {
  field(DOL1, "MGNT:LTUS:1:ALLXCORS")
  field(DOL2, "MGNT:LTUS:1:ALLXCORS")
  field(DOL3, "MGNT:LTUS:1:ALLXCORS")
  field(DOL4, "MGNT:LTUS:1:ALLXCORS")
  field(DOL5, "MGNT:LTUS:1:ALLXCORS")
  field(DOL6, "MGNT:LTUS:1:ALLXCORS")
  field(LNK1, "XCOR:LTUS:722:SELECT CPP NMS")
  field(LNK2, "XCOR:LTUS:738:SELECT CPP NMS")
  field(LNK3, "XCOR:LTUS:758:SELECT CPP NMS")
  field(LNK4, "XCOR:LTUS:768:SELECT CPP NMS")
  field(LNK5, "XCOR:LTUS:826:SELECT CPP NMS")
  field(LNK6, "XCOR:LTUS:858:SELECT CPP NMS")
}

record(seq, "MGNT:LTUS:1:ALLYCORSSEL") {
  field(DOL1, "MGNT:LTUS:1:ALLYCORS")
  field(DOL2, "MGNT:LTUS:1:ALLYCORS")
  field(DOL3, "MGNT:LTUS:1:ALLYCORS")
  field(DOL4, "MGNT:LTUS:1:ALLYCORS")
  field(LNK1, "YCOR:LTUS:111:SELECT CPP NMS")
  field(LNK2, "YCOR:LTUS:183:SELECT CPP NMS")
  field(LNK3, "YCOR:LTUS:267:SELECT CPP NMS")
  field(LNK4, "YCOR:LTUS:341:SELECT CPP NMS")
  field(FLNK, "MGNT:LTUS:1:ALLYCORSSEL_2.PROC")
}
record(seq, "MGNT:LTUS:1:ALLYCORSSEL_2") {
  field(DOL1, "MGNT:LTUS:1:ALLYCORS")
  field(DOL2, "MGNT:LTUS:1:ALLYCORS")
  field(DOL3, "MGNT:LTUS:1:ALLYCORS")
  field(DOL4, "MGNT:LTUS:1:ALLYCORS")
  field(DOL5, "MGNT:LTUS:1:ALLYCORS")
  field(DOL6, "MGNT:LTUS:1:ALLYCORS")
  field(DOL7, "MGNT:LTUS:1:ALLYCORS")
  field(DOL8, "MGNT:LTUS:1:ALLYCORS")
  field(DOL9, "MGNT:LTUS:1:ALLYCORS")
  field(LNK1, "YCOR:LTUS:427:SELECT CPP NMS")
  field(LNK2, "YCOR:LTUS:471:SELECT CPP NMS")
  field(LNK3, "YCOR:LTUS:499:SELECT CPP NMS")
  field(LNK4, "YCOR:LTUS:547:SELECT CPP NMS")
  field(LNK5, "YCOR:LTUS:561:SELECT CPP NMS")
  field(LNK6, "YCOR:LTUS:577:SELECT CPP NMS")
  field(LNK7, "YCOR:LTUS:641:SELECT CPP NMS")
  field(LNK8, "YCOR:LTUS:677:SELECT CPP NMS")
  field(LNK9, "YCOR:LTUS:721:SELECT CPP NMS")
  field(FLNK, "MGNT:LTUS:1:ALLYCORSSEL_3.PROC")
}
record(seq, "MGNT:LTUS:1:ALLYCORSSEL_3") {
  field(DOL1, "MGNT:LTUS:1:ALLYCORS")
  field(DOL2, "MGNT:LTUS:1:ALLYCORS")
  field(DOL3, "MGNT:LTUS:1:ALLYCORS")
  field(DOL4, "MGNT:LTUS:1:ALLYCORS")
  field(DOL5, "MGNT:LTUS:1:ALLYCORS")
  field(DOL6, "MGNT:LTUS:1:ALLYCORS")
  field(LNK1, "YCOR:LTUS:729:SELECT CPP NMS")
  field(LNK2, "YCOR:LTUS:749:SELECT CPP NMS")
  field(LNK3, "YCOR:LTUS:767:SELECT CPP NMS")
  field(LNK4, "YCOR:LTUS:777:SELECT CPP NMS")
  field(LNK5, "YCOR:LTUS:839:SELECT CPP NMS")
  field(LNK6, "YCOR:LTUS:877:SELECT CPP NMS")
}

record(seq, "MGNT:LTUS:1:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(LNK1, "MGNT:LTUS:1:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:LTUS:1:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:LTUS:1:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:LTUS:1:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:LTUS:1:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:LTUS:1:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:LTUS:1:LGPSFUNCGO.PROC")
  field(FLNK, "MGNT:LTUS:1:ALLFUNCGO2")
}
record(seq, "MGNT:LTUS:1:ALLFUNCGO2") {
  field(DESC, "Process CTRL func")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:LTUS:1:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:LTUS:1:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:LTUS:1:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:LTUS:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:LTUS:1:CTRLCLEAR")
}

record(fanout, "MGNT:LTUS:1:SOLNFUNCGO") {
  field(DESC, "Process All SOLNs")
  field(FLNK, "MGNT:LTUS:1:CTRLCLEAR")
}
record(fanout, "MGNT:LTUS:1:KICKFUNCGO") {
  field(DESC, "Process All KICKs")
  field(LNK1, "KICK:LTUS:350:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:CTRLCLEAR")
}
record(fanout, "MGNT:LTUS:1:SEXTFUNCGO") {
  field(DESC, "Process All SEXTs")
  field(FLNK, "MGNT:LTUS:1:CTRLCLEAR")
}

record(fanout, "MGNT:LTUS:1:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(LNK1, "BEND:LTUS:166:ALLFUNCGO")
  field(LNK2, "BEND:DMPS:400:ALLFUNCGO")
  field(LNK3, "BEND:LTUS:476:ALLFUNCGO")
  field(LNK4, "BEND:LTUS:525:ALLFUNCGO")
  field(LNK5, "BEND:LTUS:764:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:CTRLCLEAR")
}

record(fanout, "MGNT:LTUS:1:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(LNK1, "BTRM:LTUS:165:ALLFUNCGO")
  field(LNK2, "BTRM:LTUS:167:ALLFUNCGO")
  field(LNK3, "BTRM:LTUS:168:ALLFUNCGO")
  field(LNK4, "BTRM:LTUS:175:ALLFUNCGO")
  field(LNK5, "BTRM:LTUS:460:ALLFUNCGO")
  field(LNK6, "BTRM:LTUS:475:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:BTRMFUNCGO_1")
}

record(fanout, "MGNT:LTUS:1:BTRMFUNCGO_1") {
  field(DESC, "Process BTRM CTRL func")
  field(LNK1, "BTRM:LTUS:477:ALLFUNCGO")
  field(LNK2, "BTRM:LTUS:478:ALLFUNCGO")
  field(LNK3, "BTRM:LTUS:763:ALLFUNCGO")
  field(LNK4, "BTRM:LTUS:765:ALLFUNCGO")
  field(LNK5, "BTRM:LTUS:766:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:CTRLCLEAR")
}

record(fanout, "MGNT:LTUS:1:QUADFUNCGO") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:LTUS:110:ALLFUNCGO")
  field(LNK2, "QUAD:LTUS:120:ALLFUNCGO")
  field(LNK3, "QUAD:LTUS:150:ALLFUNCGO")
  field(LNK4, "QUAD:LTUS:180:ALLFUNCGO")
  field(LNK5, "QUAD:LTUS:235:ALLFUNCGO")
  field(LNK6, "QUAD:LTUS:470:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:QUADFUNCGO_2")
}
record(fanout, "MGNT:LTUS:1:QUADFUNCGO_2") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:LTUS:500:ALLFUNCGO")
  field(LNK2, "QUAD:LTUS:510:ALLFUNCGO")
  field(LNK3, "QUAD:LTUS:540:ALLFUNCGO")
  field(LNK4, "QUAD:LTUS:570:ALLFUNCGO")
  field(LNK5, "QUAD:LTUS:580:ALLFUNCGO")
  field(LNK6, "QUAD:LTUS:620:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:QUADFUNCGO_3")
}
record(fanout, "MGNT:LTUS:1:QUADFUNCGO_3") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:LTUS:640:ALLFUNCGO")
  field(LNK2, "QUAD:LTUS:660:ALLFUNCGO")
  field(LNK3, "QUAD:LTUS:665:ALLFUNCGO")
  field(LNK4, "QUAD:LTUS:680:ALLFUNCGO")
  field(LNK5, "QUAD:LTUS:720:ALLFUNCGO")
  field(LNK6, "QUAD:LTUS:725:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:QUADFUNCGO_4")
}
record(fanout, "MGNT:LTUS:1:QUADFUNCGO_4") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:LTUS:730:ALLFUNCGO")
  field(LNK2, "QUAD:LTUS:740:ALLFUNCGO")
  field(LNK3, "QUAD:LTUS:750:ALLFUNCGO")
  field(LNK4, "QUAD:LTUS:760:ALLFUNCGO")
  field(LNK5, "QUAD:LTUS:772:ALLFUNCGO")
  field(LNK6, "QUAD:LTUS:780:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:QUADFUNCGO_5")
}
record(fanout, "MGNT:LTUS:1:QUADFUNCGO_5") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:LTUS:820:ALLFUNCGO")
  field(LNK2, "QUAD:LTUS:840:ALLFUNCGO")
  field(LNK3, "QUAD:LTUS:860:ALLFUNCGO")
  field(LNK4, "QUAD:LTUS:880:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:CTRLCLEAR")
}

record(fanout, "MGNT:LTUS:1:XCORFUNCGO") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:LTUS:118:ALLFUNCGO")
  field(LNK2, "XCOR:LTUS:148:ALLFUNCGO")
  field(LNK3, "XCOR:LTUS:228:ALLFUNCGO")
  field(LNK4, "XCOR:LTUS:296:ALLFUNCGO")
  field(LNK5, "XCOR:LTUS:368:ALLFUNCGO")
  field(LNK6, "XCOR:LTUS:448:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:XCORFUNCGO_2")
}
record(fanout, "MGNT:LTUS:1:XCORFUNCGO_2") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:LTUS:508:ALLFUNCGO")
  field(LNK2, "XCOR:LTUS:548:ALLFUNCGO")
  field(LNK3, "XCOR:LTUS:568:ALLFUNCGO")
  field(LNK4, "XCOR:LTUS:616:ALLFUNCGO")
  field(LNK5, "XCOR:LTUS:658:ALLFUNCGO")
  field(LNK6, "XCOR:LTUS:718:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:XCORFUNCGO_3.PROC")
}
record(fanout, "MGNT:LTUS:1:XCORFUNCGO_3") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:LTUS:738:ALLFUNCGO")
  field(LNK2, "XCOR:LTUS:758:ALLFUNCGO")
  field(LNK3, "XCOR:LTUS:768:ALLFUNCGO")
  field(LNK4, "XCOR:LTUS:826:ALLFUNCGO")
  field(LNK5, "XCOR:LTUS:858:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:CTRLCLEAR")
}

record(fanout, "MGNT:LTUS:1:YCORFUNCGO") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:LTUS:111:ALLFUNCGO")
  field(LNK2, "YCOR:LTUS:183:ALLFUNCGO")
  field(LNK3, "YCOR:LTUS:267:ALLFUNCGO")
  field(LNK4, "YCOR:LTUS:341:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:YCORFUNCGO_2")
}
record(fanout, "MGNT:LTUS:1:YCORFUNCGO_2") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:LTUS:427:ALLFUNCGO")
  field(LNK2, "YCOR:LTUS:471:ALLFUNCGO")
  field(LNK3, "YCOR:LTUS:499:ALLFUNCGO")
  field(LNK4, "YCOR:LTUS:547:ALLFUNCGO")
  field(LNK5, "YCOR:LTUS:561:ALLFUNCGO")
  field(LNK6, "YCOR:LTUS:577:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:YCORFUNCGO_3")
}
record(fanout, "MGNT:LTUS:1:YCORFUNCGO_3") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:LTUS:641:ALLFUNCGO")
  field(LNK2, "YCOR:LTUS:677:ALLFUNCGO")
  field(LNK3, "YCOR:LTUS:721:ALLFUNCGO")
  field(LNK4, "YCOR:LTUS:729:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:YCORFUNCGO_4")
}
record(fanout, "MGNT:LTUS:1:YCORFUNCGO_4") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:LTUS:749:ALLFUNCGO")
  field(LNK2, "YCOR:LTUS:767:ALLFUNCGO")
  field(LNK3, "YCOR:LTUS:777:ALLFUNCGO")
  field(LNK4, "YCOR:LTUS:839:ALLFUNCGO")
  field(LNK5, "YCOR:LTUS:877:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:CTRLCLEAR")
}

record(fanout, "MGNT:LTUS:1:LGPSFUNCGO") {
  field(DESC, "Process LGPS CTRL func")
  field(LNK1, "LGPS:LTUS:1:ALLFUNCGO")
  field(LNK2, "LGPS:LTUS:1:ALLFUNCGO")
  field(LNK3, "LGPS:LTUS:2:ALLFUNCGO")
  field(LNK4, "LGPS:LTUS:3:ALLFUNCGO")
  field(LNK5, "LGPS:LTUS:4:ALLFUNCGO")
  field(LNK6, "LGPS:LTUS:5:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:LGPSFUNCGO_1")
}
record(fanout, "MGNT:LTUS:1:LGPSFUNCGO_1") {
  field(DESC, "Process LGPS CTRL func")
  field(LNK1, "LGPS:LTUS:6:ALLFUNCGO")
  field(LNK2, "LGPS:LTUS:7:ALLFUNCGO")
  field(FLNK, "MGNT:LTUS:1:CTRLCLEAR")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LTUH:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LTUH:1:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LTUH:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LTUH:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LTUH:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LTUH:1:EDES.PROC PP")
    field(LNK2, "LGPS:LTUH:1:EACT.PROC PP")
    field(LNK3, "LGPS:LTUH:1:EERR.DISA PP")
    field(LNK4, "LGPS:LTUH:1:ECON.PROC PP")
    field(LNK5, "LGPS:LTUH:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:LTUH:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:LTUH:1:BLEM.PROC PP")
    field(LNK8, "LGPS:LTUH:1:BMOD.PROC PP")
    field(LNK9, "LGPS:LTUH:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LTUH:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LTUH:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LTUH:1:BMAX")
  field(DOL2, "LGPS:LTUH:1:BMAX")
  field(DOL3, "LGPS:LTUH:1:BMAX")
  field(DOL4, "LGPS:LTUH:1:BMIN")
  field(DOL5, "LGPS:LTUH:1:BMIN")
  field(DOL6, "LGPS:LTUH:1:BMIN")
  field(LNK1, "LGPS:LTUH:1:BMAGX.HOPR")
  field(LNK2, "LGPS:LTUH:1:BMAGY.HOPR")
  field(LNK3, "LGPS:LTUH:1:BLEM.HOPR")
  field(LNK4, "LGPS:LTUH:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LTUH:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LTUH:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUH:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUH:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LTUH:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LTUH:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LTUH:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUH:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUH:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LTUH:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LTUH:1:EDES NPP MS")
  field(INPB, "LGPS:LTUH:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LTUH:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LTUH:1:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LTUH:1:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LTUH:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LTUH:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LTUH:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LTUH:1:EDES.PROC PP")
    field(LNK2, "LGPS:LTUH:1:EACT.PROC PP")
    field(LNK3, "LGPS:LTUH:1:EERR.DISA PP")
    field(LNK4, "LGPS:LTUH:1:ECON.PROC PP")
    field(LNK5, "LGPS:LTUH:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:LTUH:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:LTUH:1:BLEM.PROC PP")
    field(LNK8, "LGPS:LTUH:1:BMOD.PROC PP")
    field(LNK9, "LGPS:LTUH:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LTUH:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LTUH:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LTUH:1:BMAX")
  field(DOL2, "LGPS:LTUH:1:BMAX")
  field(DOL3, "LGPS:LTUH:1:BMAX")
  field(DOL4, "LGPS:LTUH:1:BMIN")
  field(DOL5, "LGPS:LTUH:1:BMIN")
  field(DOL6, "LGPS:LTUH:1:BMIN")
  field(LNK1, "LGPS:LTUH:1:BMAGX.HOPR")
  field(LNK2, "LGPS:LTUH:1:BMAGY.HOPR")
  field(LNK3, "LGPS:LTUH:1:BLEM.HOPR")
  field(LNK4, "LGPS:LTUH:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LTUH:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LTUH:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUH:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUH:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LTUH:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LTUH:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LTUH:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUH:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUH:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LTUH:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LTUH:1:EDES NPP MS")
  field(INPB, "LGPS:LTUH:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LTUH:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "LGPS:LTUH:2:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LTUH:2:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LTUH:2:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LTUH:2:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LTUH:2:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LTUH:2:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LTUH:2:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LTUH:2:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LTUH:2:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LTUH:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LTUH:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LTUH:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LTUH:2:EDES.PROC PP")
    field(LNK2, "LGPS:LTUH:2:EACT.PROC PP")
    field(LNK3, "LGPS:LTUH:2:EERR.DISA PP")
    field(LNK4, "LGPS:LTUH:2:ECON.PROC PP")
    field(LNK5, "LGPS:LTUH:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:LTUH:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:LTUH:2:BLEM.PROC PP")
    field(LNK8, "LGPS:LTUH:2:BMOD.PROC PP")
    field(LNK9, "LGPS:LTUH:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LTUH:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LTUH:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LTUH:2:BMAX")
  field(DOL2, "LGPS:LTUH:2:BMAX")
  field(DOL3, "LGPS:LTUH:2:BMAX")
  field(DOL4, "LGPS:LTUH:2:BMIN")
  field(DOL5, "LGPS:LTUH:2:BMIN")
  field(DOL6, "LGPS:LTUH:2:BMIN")
  field(LNK1, "LGPS:LTUH:2:BMAGX.HOPR")
  field(LNK2, "LGPS:LTUH:2:BMAGY.HOPR")
  field(LNK3, "LGPS:LTUH:2:BLEM.HOPR")
  field(LNK4, "LGPS:LTUH:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LTUH:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LTUH:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUH:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUH:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LTUH:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LTUH:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LTUH:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUH:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUH:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LTUH:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LTUH:2:EDES NPP MS")
  field(INPB, "LGPS:LTUH:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LTUH:3:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "LGPS:LTUH:3:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LTUH:3:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LTUH:3:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LTUH:3:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LTUH:3:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LTUH:3:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LTUH:3:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LTUH:3:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LTUH:3:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LTUH:3:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LTUH:3:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LTUH:3:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LTUH:3:EDES.PROC PP")
    field(LNK2, "LGPS:LTUH:3:EACT.PROC PP")
    field(LNK3, "LGPS:LTUH:3:EERR.DISA PP")
    field(LNK4, "LGPS:LTUH:3:ECON.PROC PP")
    field(LNK5, "LGPS:LTUH:3:BMAGX.PROC PP")
    field(LNK6, "LGPS:LTUH:3:BMAGY.PROC PP")
    field(LNK7, "LGPS:LTUH:3:BLEM.PROC PP")
    field(LNK8, "LGPS:LTUH:3:BMOD.PROC PP")
    field(LNK9, "LGPS:LTUH:3:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LTUH:3:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LTUH:3:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LTUH:3:BMAX")
  field(DOL2, "LGPS:LTUH:3:BMAX")
  field(DOL3, "LGPS:LTUH:3:BMAX")
  field(DOL4, "LGPS:LTUH:3:BMIN")
  field(DOL5, "LGPS:LTUH:3:BMIN")
  field(DOL6, "LGPS:LTUH:3:BMIN")
  field(LNK1, "LGPS:LTUH:3:BMAGX.HOPR")
  field(LNK2, "LGPS:LTUH:3:BMAGY.HOPR")
  field(LNK3, "LGPS:LTUH:3:BLEM.HOPR")
  field(LNK4, "LGPS:LTUH:3:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LTUH:3:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LTUH:3:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUH:3:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUH:3:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LTUH:3:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LTUH:3:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LTUH:3:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:3:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:3:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUH:3:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:3:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUH:3:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LTUH:3:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LTUH:3:EDES NPP MS")
  field(INPB, "LGPS:LTUH:3:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LTUH:4:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "LGPS:LTUH:4:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LTUH:4:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LTUH:4:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LTUH:4:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LTUH:4:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LTUH:4:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LTUH:4:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LTUH:4:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LTUH:4:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LTUH:4:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LTUH:4:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LTUH:4:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LTUH:4:EDES.PROC PP")
    field(LNK2, "LGPS:LTUH:4:EACT.PROC PP")
    field(LNK3, "LGPS:LTUH:4:EERR.DISA PP")
    field(LNK4, "LGPS:LTUH:4:ECON.PROC PP")
    field(LNK5, "LGPS:LTUH:4:BMAGX.PROC PP")
    field(LNK6, "LGPS:LTUH:4:BMAGY.PROC PP")
    field(LNK7, "LGPS:LTUH:4:BLEM.PROC PP")
    field(LNK8, "LGPS:LTUH:4:BMOD.PROC PP")
    field(LNK9, "LGPS:LTUH:4:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LTUH:4:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LTUH:4:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LTUH:4:BMAX")
  field(DOL2, "LGPS:LTUH:4:BMAX")
  field(DOL3, "LGPS:LTUH:4:BMAX")
  field(DOL4, "LGPS:LTUH:4:BMIN")
  field(DOL5, "LGPS:LTUH:4:BMIN")
  field(DOL6, "LGPS:LTUH:4:BMIN")
  field(LNK1, "LGPS:LTUH:4:BMAGX.HOPR")
  field(LNK2, "LGPS:LTUH:4:BMAGY.HOPR")
  field(LNK3, "LGPS:LTUH:4:BLEM.HOPR")
  field(LNK4, "LGPS:LTUH:4:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LTUH:4:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LTUH:4:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUH:4:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUH:4:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LTUH:4:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LTUH:4:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LTUH:4:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:4:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:4:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUH:4:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:4:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUH:4:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LTUH:4:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LTUH:4:EDES NPP MS")
  field(INPB, "LGPS:LTUH:4:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LTUH:5:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "LGPS:LTUH:5:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LTUH:5:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LTUH:5:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LTUH:5:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LTUH:5:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LTUH:5:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LTUH:5:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LTUH:5:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LTUH:5:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LTUH:5:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LTUH:5:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LTUH:5:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LTUH:5:EDES.PROC PP")
    field(LNK2, "LGPS:LTUH:5:EACT.PROC PP")
    field(LNK3, "LGPS:LTUH:5:EERR.DISA PP")
    field(LNK4, "LGPS:LTUH:5:ECON.PROC PP")
    field(LNK5, "LGPS:LTUH:5:BMAGX.PROC PP")
    field(LNK6, "LGPS:LTUH:5:BMAGY.PROC PP")
    field(LNK7, "LGPS:LTUH:5:BLEM.PROC PP")
    field(LNK8, "LGPS:LTUH:5:BMOD.PROC PP")
    field(LNK9, "LGPS:LTUH:5:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LTUH:5:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LTUH:5:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LTUH:5:BMAX")
  field(DOL2, "LGPS:LTUH:5:BMAX")
  field(DOL3, "LGPS:LTUH:5:BMAX")
  field(DOL4, "LGPS:LTUH:5:BMIN")
  field(DOL5, "LGPS:LTUH:5:BMIN")
  field(DOL6, "LGPS:LTUH:5:BMIN")
  field(LNK1, "LGPS:LTUH:5:BMAGX.HOPR")
  field(LNK2, "LGPS:LTUH:5:BMAGY.HOPR")
  field(LNK3, "LGPS:LTUH:5:BLEM.HOPR")
  field(LNK4, "LGPS:LTUH:5:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LTUH:5:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LTUH:5:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUH:5:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUH:5:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LTUH:5:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LTUH:5:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LTUH:5:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:5:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:5:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUH:5:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUH:5:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUH:5:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LTUH:5:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LTUH:5:EDES NPP MS")
  field(INPB, "LGPS:LTUH:5:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:LTUH:320:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "KICK:LTUH:320:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:LTUH:320:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:LTUH:320:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:LTUH:320:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:LTUH:320:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:LTUH:320:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:LTUH:320:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:LTUH:320:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:LTUH:320:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:LTUH:320:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:LTUH:320:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:LTUH:320:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:LTUH:320:EDES.PROC PP")
    field(LNK2, "KICK:LTUH:320:EACT.PROC PP")
    field(LNK3, "KICK:LTUH:320:EERR.DISA PP")
    field(LNK4, "KICK:LTUH:320:ECON.PROC PP")
    field(LNK5, "KICK:LTUH:320:BMAGX.PROC PP")
    field(LNK6, "KICK:LTUH:320:BMAGY.PROC PP")
    field(LNK7, "KICK:LTUH:320:BLEM.PROC PP")
    field(LNK8, "KICK:LTUH:320:BMOD.PROC PP")
    field(LNK9, "KICK:LTUH:320:EDESSAVE.PROC PP")
    field(LNKA, "KICK:LTUH:320:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:LTUH:320:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:LTUH:320:BMAX")
  field(DOL2, "KICK:LTUH:320:BMAX")
  field(DOL3, "KICK:LTUH:320:BMAX")
  field(DOL4, "KICK:LTUH:320:BMIN")
  field(DOL5, "KICK:LTUH:320:BMIN")
  field(DOL6, "KICK:LTUH:320:BMIN")
  field(LNK1, "KICK:LTUH:320:BMAGX.HOPR")
  field(LNK2, "KICK:LTUH:320:BMAGY.HOPR")
  field(LNK3, "KICK:LTUH:320:BLEM.HOPR")
  field(LNK4, "KICK:LTUH:320:BMAGX.LOPR PP")
  field(LNK5, "KICK:LTUH:320:BMAGY.LOPR PP")
  field(LNK6, "KICK:LTUH:320:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:LTUH:320:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:LTUH:320:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:LTUH:320:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:LTUH:320:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:LTUH:320:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LTUH:320:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LTUH:320:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LTUH:320:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LTUH:320:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LTUH:320:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:LTUH:320:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:LTUH:320:EDES NPP MS")
  field(INPB, "KICK:LTUH:320:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:LTUH:340:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "KICK:LTUH:340:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:LTUH:340:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:LTUH:340:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:LTUH:340:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:LTUH:340:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:LTUH:340:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:LTUH:340:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:LTUH:340:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:LTUH:340:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:LTUH:340:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:LTUH:340:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:LTUH:340:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:LTUH:340:EDES.PROC PP")
    field(LNK2, "KICK:LTUH:340:EACT.PROC PP")
    field(LNK3, "KICK:LTUH:340:EERR.DISA PP")
    field(LNK4, "KICK:LTUH:340:ECON.PROC PP")
    field(LNK5, "KICK:LTUH:340:BMAGX.PROC PP")
    field(LNK6, "KICK:LTUH:340:BMAGY.PROC PP")
    field(LNK7, "KICK:LTUH:340:BLEM.PROC PP")
    field(LNK8, "KICK:LTUH:340:BMOD.PROC PP")
    field(LNK9, "KICK:LTUH:340:EDESSAVE.PROC PP")
    field(LNKA, "KICK:LTUH:340:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:LTUH:340:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:LTUH:340:BMAX")
  field(DOL2, "KICK:LTUH:340:BMAX")
  field(DOL3, "KICK:LTUH:340:BMAX")
  field(DOL4, "KICK:LTUH:340:BMIN")
  field(DOL5, "KICK:LTUH:340:BMIN")
  field(DOL6, "KICK:LTUH:340:BMIN")
  field(LNK1, "KICK:LTUH:340:BMAGX.HOPR")
  field(LNK2, "KICK:LTUH:340:BMAGY.HOPR")
  field(LNK3, "KICK:LTUH:340:BLEM.HOPR")
  field(LNK4, "KICK:LTUH:340:BMAGX.LOPR PP")
  field(LNK5, "KICK:LTUH:340:BMAGY.LOPR PP")
  field(LNK6, "KICK:LTUH:340:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:LTUH:340:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:LTUH:340:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:LTUH:340:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:LTUH:340:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:LTUH:340:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LTUH:340:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LTUH:340:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LTUH:340:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LTUH:340:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LTUH:340:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:LTUH:340:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:LTUH:340:EDES NPP MS")
  field(INPB, "KICK:LTUH:340:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:125:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:125:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:125:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:125:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:125:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:125:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:125:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:125:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:125:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:125:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:125:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:125:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:125:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:125:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:125:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:125:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:125:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:125:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:125:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:125:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:125:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:125:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:125:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:125:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:125:BMAX")
  field(DOL2, "BEND:LTUH:125:BMAX")
  field(DOL3, "BEND:LTUH:125:BMAX")
  field(DOL4, "BEND:LTUH:125:BMIN")
  field(DOL5, "BEND:LTUH:125:BMIN")
  field(DOL6, "BEND:LTUH:125:BMIN")
  field(LNK1, "BEND:LTUH:125:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:125:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:125:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:125:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:125:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:125:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:125:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:125:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:125:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:125:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:125:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:125:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:125:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUH:125:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:125:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUH:125:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:125:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:125:EDES NPP MS")
  field(INPB, "BEND:LTUH:125:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:220:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:220:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:220:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:220:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:220:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:220:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:220:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:220:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:220:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:220:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:220:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:220:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:220:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:220:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:220:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:220:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:220:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:220:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:220:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:220:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:220:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:220:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:220:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:220:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:220:BMAX")
  field(DOL2, "BEND:LTUH:220:BMAX")
  field(DOL3, "BEND:LTUH:220:BMAX")
  field(DOL4, "BEND:LTUH:220:BMIN")
  field(DOL5, "BEND:LTUH:220:BMIN")
  field(DOL6, "BEND:LTUH:220:BMIN")
  field(LNK1, "BEND:LTUH:220:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:220:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:220:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:220:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:220:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:220:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:220:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:220:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:220:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:220:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:220:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:220:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:220:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUH:220:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:220:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUH:220:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:220:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:220:EDES NPP MS")
  field(INPB, "BEND:LTUH:220:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:301:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:301:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:301:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:301:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:301:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:301:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:301:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:301:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:301:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:301:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:301:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:301:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:301:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:301:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:301:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:301:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:301:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:301:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:301:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:301:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:301:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:301:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:301:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:301:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:301:BMAX")
  field(DOL2, "BEND:LTUH:301:BMAX")
  field(DOL3, "BEND:LTUH:301:BMAX")
  field(DOL4, "BEND:LTUH:301:BMIN")
  field(DOL5, "BEND:LTUH:301:BMIN")
  field(DOL6, "BEND:LTUH:301:BMIN")
  field(LNK1, "BEND:LTUH:301:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:301:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:301:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:301:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:301:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:301:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:301:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:301:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:301:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:301:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:301:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:301:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:301:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUH:301:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:301:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUH:301:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:301:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:301:EDES NPP MS")
  field(INPB, "BEND:LTUH:301:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:376:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:376:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:376:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:376:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:376:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:376:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:376:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:376:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:376:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:376:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:376:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:376:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:376:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:376:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:376:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:376:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:376:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:376:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:376:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:376:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:376:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:376:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:376:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:376:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:376:BMAX")
  field(DOL2, "BEND:LTUH:376:BMAX")
  field(DOL3, "BEND:LTUH:376:BMAX")
  field(DOL4, "BEND:LTUH:376:BMIN")
  field(DOL5, "BEND:LTUH:376:BMIN")
  field(DOL6, "BEND:LTUH:376:BMIN")
  field(LNK1, "BEND:LTUH:376:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:376:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:376:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:376:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:376:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:376:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:376:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:376:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:376:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:376:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:376:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:376:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:376:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUH:376:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:376:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUH:376:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:376:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:376:EDES NPP MS")
  field(INPB, "BEND:LTUH:376:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:506:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:506:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:506:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:506:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:506:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:506:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:506:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:506:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:506:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:506:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:506:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:506:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:506:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:506:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:506:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:506:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:506:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:506:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:506:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:506:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:506:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:506:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:506:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:506:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:506:BMAX")
  field(DOL2, "BEND:LTUH:506:BMAX")
  field(DOL3, "BEND:LTUH:506:BMAX")
  field(DOL4, "BEND:LTUH:506:BMIN")
  field(DOL5, "BEND:LTUH:506:BMIN")
  field(DOL6, "BEND:LTUH:506:BMIN")
  field(LNK1, "BEND:LTUH:506:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:506:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:506:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:506:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:506:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:506:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:506:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:506:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:506:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:506:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:506:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:506:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:506:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUH:506:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:506:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUH:506:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:506:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:506:EDES NPP MS")
  field(INPB, "BEND:LTUH:506:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUH:220:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUH:220:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUH:220:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUH:220:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUH:220:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUH:220:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUH:220:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUH:220:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUH:220:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUH:220:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUH:220:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUH:220:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUH:220:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUH:220:EDES.PROC PP")
    field(LNK2, "BTRM:LTUH:220:EACT.PROC PP")
    field(LNK3, "BTRM:LTUH:220:EERR.DISA PP")
    field(LNK4, "BTRM:LTUH:220:ECON.PROC PP")
    field(LNK5, "BTRM:LTUH:220:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUH:220:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUH:220:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUH:220:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUH:220:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUH:220:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUH:220:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUH:220:BMAX")
  field(DOL2, "BTRM:LTUH:220:BMAX")
  field(DOL3, "BTRM:LTUH:220:BMAX")
  field(DOL4, "BTRM:LTUH:220:BMIN")
  field(DOL5, "BTRM:LTUH:220:BMIN")
  field(DOL6, "BTRM:LTUH:220:BMIN")
  field(LNK1, "BTRM:LTUH:220:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUH:220:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUH:220:BLEM.HOPR")
  field(LNK4, "BTRM:LTUH:220:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUH:220:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUH:220:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:220:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:220:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUH:220:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUH:220:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUH:220:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:220:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:220:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:220:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:220:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:220:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUH:220:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUH:220:EDES NPP MS")
  field(INPB, "BTRM:LTUH:220:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUH:280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUH:280:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUH:280:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUH:280:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUH:280:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUH:280:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUH:280:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUH:280:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUH:280:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUH:280:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUH:280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUH:280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUH:280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUH:280:EDES.PROC PP")
    field(LNK2, "BTRM:LTUH:280:EACT.PROC PP")
    field(LNK3, "BTRM:LTUH:280:EERR.DISA PP")
    field(LNK4, "BTRM:LTUH:280:ECON.PROC PP")
    field(LNK5, "BTRM:LTUH:280:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUH:280:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUH:280:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUH:280:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUH:280:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUH:280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUH:280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUH:280:BMAX")
  field(DOL2, "BTRM:LTUH:280:BMAX")
  field(DOL3, "BTRM:LTUH:280:BMAX")
  field(DOL4, "BTRM:LTUH:280:BMIN")
  field(DOL5, "BTRM:LTUH:280:BMIN")
  field(DOL6, "BTRM:LTUH:280:BMIN")
  field(LNK1, "BTRM:LTUH:280:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUH:280:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUH:280:BLEM.HOPR")
  field(LNK4, "BTRM:LTUH:280:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUH:280:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUH:280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUH:280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUH:280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUH:280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUH:280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUH:280:EDES NPP MS")
  field(INPB, "BTRM:LTUH:280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUH:300:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUH:300:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUH:300:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUH:300:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUH:300:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUH:300:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUH:300:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUH:300:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUH:300:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUH:300:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUH:300:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUH:300:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUH:300:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUH:300:EDES.PROC PP")
    field(LNK2, "BTRM:LTUH:300:EACT.PROC PP")
    field(LNK3, "BTRM:LTUH:300:EERR.DISA PP")
    field(LNK4, "BTRM:LTUH:300:ECON.PROC PP")
    field(LNK5, "BTRM:LTUH:300:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUH:300:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUH:300:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUH:300:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUH:300:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUH:300:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUH:300:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUH:300:BMAX")
  field(DOL2, "BTRM:LTUH:300:BMAX")
  field(DOL3, "BTRM:LTUH:300:BMAX")
  field(DOL4, "BTRM:LTUH:300:BMIN")
  field(DOL5, "BTRM:LTUH:300:BMIN")
  field(DOL6, "BTRM:LTUH:300:BMIN")
  field(LNK1, "BTRM:LTUH:300:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUH:300:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUH:300:BLEM.HOPR")
  field(LNK4, "BTRM:LTUH:300:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUH:300:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUH:300:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:300:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:300:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUH:300:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUH:300:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUH:300:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:300:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:300:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:300:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:300:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:300:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUH:300:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUH:300:EDES NPP MS")
  field(INPB, "BTRM:LTUH:300:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUH:302:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUH:302:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUH:302:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUH:302:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUH:302:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUH:302:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUH:302:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUH:302:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUH:302:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUH:302:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUH:302:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUH:302:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUH:302:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUH:302:EDES.PROC PP")
    field(LNK2, "BTRM:LTUH:302:EACT.PROC PP")
    field(LNK3, "BTRM:LTUH:302:EERR.DISA PP")
    field(LNK4, "BTRM:LTUH:302:ECON.PROC PP")
    field(LNK5, "BTRM:LTUH:302:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUH:302:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUH:302:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUH:302:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUH:302:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUH:302:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUH:302:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUH:302:BMAX")
  field(DOL2, "BTRM:LTUH:302:BMAX")
  field(DOL3, "BTRM:LTUH:302:BMAX")
  field(DOL4, "BTRM:LTUH:302:BMIN")
  field(DOL5, "BTRM:LTUH:302:BMIN")
  field(DOL6, "BTRM:LTUH:302:BMIN")
  field(LNK1, "BTRM:LTUH:302:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUH:302:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUH:302:BLEM.HOPR")
  field(LNK4, "BTRM:LTUH:302:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUH:302:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUH:302:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:302:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:302:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUH:302:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUH:302:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUH:302:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:302:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:302:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:302:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:302:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:302:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUH:302:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUH:302:EDES NPP MS")
  field(INPB, "BTRM:LTUH:302:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUH:303:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUH:303:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUH:303:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUH:303:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUH:303:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUH:303:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUH:303:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUH:303:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUH:303:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUH:303:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUH:303:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUH:303:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUH:303:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUH:303:EDES.PROC PP")
    field(LNK2, "BTRM:LTUH:303:EACT.PROC PP")
    field(LNK3, "BTRM:LTUH:303:EERR.DISA PP")
    field(LNK4, "BTRM:LTUH:303:ECON.PROC PP")
    field(LNK5, "BTRM:LTUH:303:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUH:303:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUH:303:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUH:303:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUH:303:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUH:303:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUH:303:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUH:303:BMAX")
  field(DOL2, "BTRM:LTUH:303:BMAX")
  field(DOL3, "BTRM:LTUH:303:BMAX")
  field(DOL4, "BTRM:LTUH:303:BMIN")
  field(DOL5, "BTRM:LTUH:303:BMIN")
  field(DOL6, "BTRM:LTUH:303:BMIN")
  field(LNK1, "BTRM:LTUH:303:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUH:303:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUH:303:BLEM.HOPR")
  field(LNK4, "BTRM:LTUH:303:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUH:303:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUH:303:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:303:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:303:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUH:303:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUH:303:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUH:303:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:303:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:303:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:303:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:303:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:303:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUH:303:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUH:303:EDES NPP MS")
  field(INPB, "BTRM:LTUH:303:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUH:375:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUH:375:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUH:375:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUH:375:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUH:375:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUH:375:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUH:375:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUH:375:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUH:375:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUH:375:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUH:375:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUH:375:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUH:375:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUH:375:EDES.PROC PP")
    field(LNK2, "BTRM:LTUH:375:EACT.PROC PP")
    field(LNK3, "BTRM:LTUH:375:EERR.DISA PP")
    field(LNK4, "BTRM:LTUH:375:ECON.PROC PP")
    field(LNK5, "BTRM:LTUH:375:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUH:375:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUH:375:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUH:375:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUH:375:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUH:375:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUH:375:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUH:375:BMAX")
  field(DOL2, "BTRM:LTUH:375:BMAX")
  field(DOL3, "BTRM:LTUH:375:BMAX")
  field(DOL4, "BTRM:LTUH:375:BMIN")
  field(DOL5, "BTRM:LTUH:375:BMIN")
  field(DOL6, "BTRM:LTUH:375:BMIN")
  field(LNK1, "BTRM:LTUH:375:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUH:375:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUH:375:BLEM.HOPR")
  field(LNK4, "BTRM:LTUH:375:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUH:375:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUH:375:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:375:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:375:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUH:375:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUH:375:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUH:375:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:375:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:375:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:375:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:375:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:375:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUH:375:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUH:375:EDES NPP MS")
  field(INPB, "BTRM:LTUH:375:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUH:377:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUH:377:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUH:377:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUH:377:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUH:377:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUH:377:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUH:377:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUH:377:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUH:377:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUH:377:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUH:377:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUH:377:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUH:377:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUH:377:EDES.PROC PP")
    field(LNK2, "BTRM:LTUH:377:EACT.PROC PP")
    field(LNK3, "BTRM:LTUH:377:EERR.DISA PP")
    field(LNK4, "BTRM:LTUH:377:ECON.PROC PP")
    field(LNK5, "BTRM:LTUH:377:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUH:377:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUH:377:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUH:377:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUH:377:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUH:377:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUH:377:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUH:377:BMAX")
  field(DOL2, "BTRM:LTUH:377:BMAX")
  field(DOL3, "BTRM:LTUH:377:BMAX")
  field(DOL4, "BTRM:LTUH:377:BMIN")
  field(DOL5, "BTRM:LTUH:377:BMIN")
  field(DOL6, "BTRM:LTUH:377:BMIN")
  field(LNK1, "BTRM:LTUH:377:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUH:377:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUH:377:BLEM.HOPR")
  field(LNK4, "BTRM:LTUH:377:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUH:377:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUH:377:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:377:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:377:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUH:377:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUH:377:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUH:377:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:377:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:377:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:377:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:377:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:377:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUH:377:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUH:377:EDES NPP MS")
  field(INPB, "BTRM:LTUH:377:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUH:378:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUH:378:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUH:378:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUH:378:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUH:378:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUH:378:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUH:378:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUH:378:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUH:378:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUH:378:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUH:378:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUH:378:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUH:378:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUH:378:EDES.PROC PP")
    field(LNK2, "BTRM:LTUH:378:EACT.PROC PP")
    field(LNK3, "BTRM:LTUH:378:EERR.DISA PP")
    field(LNK4, "BTRM:LTUH:378:ECON.PROC PP")
    field(LNK5, "BTRM:LTUH:378:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUH:378:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUH:378:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUH:378:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUH:378:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUH:378:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUH:378:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUH:378:BMAX")
  field(DOL2, "BTRM:LTUH:378:BMAX")
  field(DOL3, "BTRM:LTUH:378:BMAX")
  field(DOL4, "BTRM:LTUH:378:BMIN")
  field(DOL5, "BTRM:LTUH:378:BMIN")
  field(DOL6, "BTRM:LTUH:378:BMIN")
  field(LNK1, "BTRM:LTUH:378:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUH:378:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUH:378:BLEM.HOPR")
  field(LNK4, "BTRM:LTUH:378:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUH:378:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUH:378:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:378:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:378:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUH:378:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUH:378:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUH:378:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:378:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:378:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:378:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:378:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:378:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUH:378:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUH:378:EDES NPP MS")
  field(INPB, "BTRM:LTUH:378:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUH:420:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUH:420:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUH:420:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUH:420:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUH:420:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUH:420:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUH:420:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUH:420:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUH:420:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUH:420:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUH:420:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUH:420:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUH:420:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUH:420:EDES.PROC PP")
    field(LNK2, "BTRM:LTUH:420:EACT.PROC PP")
    field(LNK3, "BTRM:LTUH:420:EERR.DISA PP")
    field(LNK4, "BTRM:LTUH:420:ECON.PROC PP")
    field(LNK5, "BTRM:LTUH:420:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUH:420:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUH:420:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUH:420:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUH:420:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUH:420:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUH:420:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUH:420:BMAX")
  field(DOL2, "BTRM:LTUH:420:BMAX")
  field(DOL3, "BTRM:LTUH:420:BMAX")
  field(DOL4, "BTRM:LTUH:420:BMIN")
  field(DOL5, "BTRM:LTUH:420:BMIN")
  field(DOL6, "BTRM:LTUH:420:BMIN")
  field(LNK1, "BTRM:LTUH:420:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUH:420:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUH:420:BLEM.HOPR")
  field(LNK4, "BTRM:LTUH:420:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUH:420:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUH:420:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:420:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:420:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUH:420:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUH:420:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUH:420:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:420:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:420:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:420:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:420:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:420:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUH:420:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUH:420:EDES NPP MS")
  field(INPB, "BTRM:LTUH:420:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUH:480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUH:480:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUH:480:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUH:480:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUH:480:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUH:480:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUH:480:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUH:480:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUH:480:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUH:480:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUH:480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUH:480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUH:480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUH:480:EDES.PROC PP")
    field(LNK2, "BTRM:LTUH:480:EACT.PROC PP")
    field(LNK3, "BTRM:LTUH:480:EERR.DISA PP")
    field(LNK4, "BTRM:LTUH:480:ECON.PROC PP")
    field(LNK5, "BTRM:LTUH:480:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUH:480:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUH:480:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUH:480:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUH:480:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUH:480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUH:480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUH:480:BMAX")
  field(DOL2, "BTRM:LTUH:480:BMAX")
  field(DOL3, "BTRM:LTUH:480:BMAX")
  field(DOL4, "BTRM:LTUH:480:BMIN")
  field(DOL5, "BTRM:LTUH:480:BMIN")
  field(DOL6, "BTRM:LTUH:480:BMIN")
  field(LNK1, "BTRM:LTUH:480:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUH:480:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUH:480:BLEM.HOPR")
  field(LNK4, "BTRM:LTUH:480:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUH:480:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUH:480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUH:480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUH:480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUH:480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUH:480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUH:480:EDES NPP MS")
  field(INPB, "BTRM:LTUH:480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUH:505:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUH:505:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUH:505:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUH:505:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUH:505:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUH:505:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUH:505:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUH:505:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUH:505:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUH:505:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUH:505:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUH:505:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUH:505:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUH:505:EDES.PROC PP")
    field(LNK2, "BTRM:LTUH:505:EACT.PROC PP")
    field(LNK3, "BTRM:LTUH:505:EERR.DISA PP")
    field(LNK4, "BTRM:LTUH:505:ECON.PROC PP")
    field(LNK5, "BTRM:LTUH:505:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUH:505:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUH:505:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUH:505:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUH:505:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUH:505:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUH:505:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUH:505:BMAX")
  field(DOL2, "BTRM:LTUH:505:BMAX")
  field(DOL3, "BTRM:LTUH:505:BMAX")
  field(DOL4, "BTRM:LTUH:505:BMIN")
  field(DOL5, "BTRM:LTUH:505:BMIN")
  field(DOL6, "BTRM:LTUH:505:BMIN")
  field(LNK1, "BTRM:LTUH:505:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUH:505:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUH:505:BLEM.HOPR")
  field(LNK4, "BTRM:LTUH:505:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUH:505:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUH:505:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:505:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:505:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUH:505:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUH:505:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUH:505:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:505:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:505:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:505:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:505:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:505:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUH:505:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUH:505:EDES NPP MS")
  field(INPB, "BTRM:LTUH:505:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUH:507:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUH:507:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUH:507:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUH:507:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUH:507:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUH:507:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUH:507:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUH:507:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUH:507:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUH:507:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUH:507:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUH:507:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUH:507:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUH:507:EDES.PROC PP")
    field(LNK2, "BTRM:LTUH:507:EACT.PROC PP")
    field(LNK3, "BTRM:LTUH:507:EERR.DISA PP")
    field(LNK4, "BTRM:LTUH:507:ECON.PROC PP")
    field(LNK5, "BTRM:LTUH:507:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUH:507:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUH:507:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUH:507:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUH:507:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUH:507:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUH:507:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUH:507:BMAX")
  field(DOL2, "BTRM:LTUH:507:BMAX")
  field(DOL3, "BTRM:LTUH:507:BMAX")
  field(DOL4, "BTRM:LTUH:507:BMIN")
  field(DOL5, "BTRM:LTUH:507:BMIN")
  field(DOL6, "BTRM:LTUH:507:BMIN")
  field(LNK1, "BTRM:LTUH:507:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUH:507:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUH:507:BLEM.HOPR")
  field(LNK4, "BTRM:LTUH:507:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUH:507:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUH:507:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:507:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:507:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUH:507:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUH:507:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUH:507:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:507:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:507:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:507:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:507:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:507:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUH:507:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUH:507:EDES NPP MS")
  field(INPB, "BTRM:LTUH:507:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUH:508:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUH:508:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUH:508:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUH:508:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUH:508:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUH:508:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUH:508:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUH:508:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUH:508:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUH:508:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUH:508:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUH:508:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUH:508:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUH:508:EDES.PROC PP")
    field(LNK2, "BTRM:LTUH:508:EACT.PROC PP")
    field(LNK3, "BTRM:LTUH:508:EERR.DISA PP")
    field(LNK4, "BTRM:LTUH:508:ECON.PROC PP")
    field(LNK5, "BTRM:LTUH:508:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUH:508:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUH:508:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUH:508:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUH:508:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUH:508:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUH:508:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUH:508:BMAX")
  field(DOL2, "BTRM:LTUH:508:BMAX")
  field(DOL3, "BTRM:LTUH:508:BMAX")
  field(DOL4, "BTRM:LTUH:508:BMIN")
  field(DOL5, "BTRM:LTUH:508:BMIN")
  field(DOL6, "BTRM:LTUH:508:BMIN")
  field(LNK1, "BTRM:LTUH:508:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUH:508:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUH:508:BLEM.HOPR")
  field(LNK4, "BTRM:LTUH:508:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUH:508:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUH:508:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:508:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUH:508:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUH:508:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUH:508:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUH:508:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:508:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:508:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:508:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUH:508:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUH:508:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUH:508:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUH:508:EDES NPP MS")
  field(INPB, "BTRM:LTUH:508:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:110:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:110:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:110:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:110:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:110:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:110:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:110:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:110:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:110:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:110:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:110:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:110:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:110:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:110:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:110:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:110:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:110:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:110:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:110:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:110:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:110:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:110:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:110:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:110:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:110:BMAX")
  field(DOL2, "QUAD:LTUH:110:BMAX")
  field(DOL3, "QUAD:LTUH:110:BMAX")
  field(DOL4, "QUAD:LTUH:110:BMIN")
  field(DOL5, "QUAD:LTUH:110:BMIN")
  field(DOL6, "QUAD:LTUH:110:BMIN")
  field(LNK1, "QUAD:LTUH:110:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:110:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:110:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:110:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:110:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:110:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:110:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:110:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:110:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:110:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:110:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:110:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:110:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:110:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:110:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:110:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:110:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:110:EDES NPP MS")
  field(INPB, "QUAD:LTUH:110:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:120:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:120:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:120:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:120:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:120:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:120:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:120:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:120:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:120:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:120:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:120:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:120:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:120:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:120:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:120:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:120:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:120:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:120:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:120:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:120:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:120:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:120:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:120:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:120:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:120:BMAX")
  field(DOL2, "QUAD:LTUH:120:BMAX")
  field(DOL3, "QUAD:LTUH:120:BMAX")
  field(DOL4, "QUAD:LTUH:120:BMIN")
  field(DOL5, "QUAD:LTUH:120:BMIN")
  field(DOL6, "QUAD:LTUH:120:BMIN")
  field(LNK1, "QUAD:LTUH:120:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:120:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:120:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:120:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:120:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:120:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:120:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:120:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:120:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:120:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:120:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:120:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:120:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:120:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:120:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:120:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:120:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:120:EDES NPP MS")
  field(INPB, "QUAD:LTUH:120:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:130:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:130:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:130:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:130:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:130:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:130:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:130:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:130:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:130:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:130:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:130:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:130:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:130:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:130:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:130:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:130:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:130:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:130:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:130:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:130:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:130:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:130:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:130:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:130:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:130:BMAX")
  field(DOL2, "QUAD:LTUH:130:BMAX")
  field(DOL3, "QUAD:LTUH:130:BMAX")
  field(DOL4, "QUAD:LTUH:130:BMIN")
  field(DOL5, "QUAD:LTUH:130:BMIN")
  field(DOL6, "QUAD:LTUH:130:BMIN")
  field(LNK1, "QUAD:LTUH:130:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:130:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:130:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:130:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:130:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:130:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:130:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:130:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:130:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:130:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:130:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:130:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:130:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:130:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:130:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:130:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:130:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:130:EDES NPP MS")
  field(INPB, "QUAD:LTUH:130:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:180:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:180:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:180:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:180:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:180:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:180:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:180:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:180:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:180:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:180:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:180:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:180:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:180:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:180:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:180:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:180:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:180:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:180:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:180:BMAX")
  field(DOL2, "QUAD:LTUH:180:BMAX")
  field(DOL3, "QUAD:LTUH:180:BMAX")
  field(DOL4, "QUAD:LTUH:180:BMIN")
  field(DOL5, "QUAD:LTUH:180:BMIN")
  field(DOL6, "QUAD:LTUH:180:BMIN")
  field(LNK1, "QUAD:LTUH:180:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:180:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:180:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:180:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:180:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:180:EDES NPP MS")
  field(INPB, "QUAD:LTUH:180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:190:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:190:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:190:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:190:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:190:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:190:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:190:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:190:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:190:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:190:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:190:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:190:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:190:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:190:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:190:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:190:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:190:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:190:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:190:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:190:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:190:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:190:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:190:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:190:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:190:BMAX")
  field(DOL2, "QUAD:LTUH:190:BMAX")
  field(DOL3, "QUAD:LTUH:190:BMAX")
  field(DOL4, "QUAD:LTUH:190:BMIN")
  field(DOL5, "QUAD:LTUH:190:BMIN")
  field(DOL6, "QUAD:LTUH:190:BMIN")
  field(LNK1, "QUAD:LTUH:190:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:190:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:190:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:190:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:190:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:190:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:190:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:190:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:190:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:190:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:190:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:190:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:190:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:190:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:190:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:190:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:190:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:190:EDES NPP MS")
  field(INPB, "QUAD:LTUH:190:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:250:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:250:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:250:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:250:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:250:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:250:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:250:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:250:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:250:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:250:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:250:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:250:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:250:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:250:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:250:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:250:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:250:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:250:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:250:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:250:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:250:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:250:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:250:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:250:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:250:BMAX")
  field(DOL2, "QUAD:LTUH:250:BMAX")
  field(DOL3, "QUAD:LTUH:250:BMAX")
  field(DOL4, "QUAD:LTUH:250:BMIN")
  field(DOL5, "QUAD:LTUH:250:BMIN")
  field(DOL6, "QUAD:LTUH:250:BMIN")
  field(LNK1, "QUAD:LTUH:250:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:250:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:250:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:250:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:250:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:250:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:250:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:250:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:250:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:250:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:250:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:250:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:250:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:250:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:250:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:250:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:250:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:250:EDES NPP MS")
  field(INPB, "QUAD:LTUH:250:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:285:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:285:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:285:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:285:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:285:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:285:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:285:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:285:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:285:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:285:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:285:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:285:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:285:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:285:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:285:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:285:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:285:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:285:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:285:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:285:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:285:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:285:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:285:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:285:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:285:BMAX")
  field(DOL2, "QUAD:LTUH:285:BMAX")
  field(DOL3, "QUAD:LTUH:285:BMAX")
  field(DOL4, "QUAD:LTUH:285:BMIN")
  field(DOL5, "QUAD:LTUH:285:BMIN")
  field(DOL6, "QUAD:LTUH:285:BMIN")
  field(LNK1, "QUAD:LTUH:285:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:285:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:285:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:285:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:285:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:285:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:285:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:285:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:285:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:285:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:285:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:285:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:285:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:285:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:285:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:285:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:285:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:285:EDES NPP MS")
  field(INPB, "QUAD:LTUH:285:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:290:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:290:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:290:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:290:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:290:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:290:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:290:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:290:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:290:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:290:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:290:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:290:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:290:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:290:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:290:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:290:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:290:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:290:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:290:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:290:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:290:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:290:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:290:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:290:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:290:BMAX")
  field(DOL2, "QUAD:LTUH:290:BMAX")
  field(DOL3, "QUAD:LTUH:290:BMAX")
  field(DOL4, "QUAD:LTUH:290:BMIN")
  field(DOL5, "QUAD:LTUH:290:BMIN")
  field(DOL6, "QUAD:LTUH:290:BMIN")
  field(LNK1, "QUAD:LTUH:290:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:290:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:290:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:290:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:290:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:290:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:290:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:290:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:290:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:290:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:290:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:290:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:290:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:290:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:290:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:290:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:290:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:290:EDES NPP MS")
  field(INPB, "QUAD:LTUH:290:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:440:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:440:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:440:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:440:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:440:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:440:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:440:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:440:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:440:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:440:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:440:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:440:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:440:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:440:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:440:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:440:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:440:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:440:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:440:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:440:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:440:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:440:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:440:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:440:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:440:BMAX")
  field(DOL2, "QUAD:LTUH:440:BMAX")
  field(DOL3, "QUAD:LTUH:440:BMAX")
  field(DOL4, "QUAD:LTUH:440:BMIN")
  field(DOL5, "QUAD:LTUH:440:BMIN")
  field(DOL6, "QUAD:LTUH:440:BMIN")
  field(LNK1, "QUAD:LTUH:440:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:440:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:440:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:440:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:440:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:440:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:440:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:440:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:440:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:440:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:440:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:440:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:440:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:440:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:440:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:440:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:440:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:440:EDES NPP MS")
  field(INPB, "QUAD:LTUH:440:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:460:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:460:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:460:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:460:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:460:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:460:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:460:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:460:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:460:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:460:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:460:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:460:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:460:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:460:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:460:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:460:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:460:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:460:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:460:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:460:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:460:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:460:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:460:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:460:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:460:BMAX")
  field(DOL2, "QUAD:LTUH:460:BMAX")
  field(DOL3, "QUAD:LTUH:460:BMAX")
  field(DOL4, "QUAD:LTUH:460:BMIN")
  field(DOL5, "QUAD:LTUH:460:BMIN")
  field(DOL6, "QUAD:LTUH:460:BMIN")
  field(LNK1, "QUAD:LTUH:460:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:460:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:460:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:460:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:460:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:460:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:460:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:460:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:460:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:460:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:460:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:460:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:460:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:460:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:460:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:460:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:460:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:460:EDES NPP MS")
  field(INPB, "QUAD:LTUH:460:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:620:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:620:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:620:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:620:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:620:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:620:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:620:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:620:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:620:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:620:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:620:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:620:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:620:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:620:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:620:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:620:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:620:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:620:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:620:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:620:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:620:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:620:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:620:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:620:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:620:BMAX")
  field(DOL2, "QUAD:LTUH:620:BMAX")
  field(DOL3, "QUAD:LTUH:620:BMAX")
  field(DOL4, "QUAD:LTUH:620:BMIN")
  field(DOL5, "QUAD:LTUH:620:BMIN")
  field(DOL6, "QUAD:LTUH:620:BMIN")
  field(LNK1, "QUAD:LTUH:620:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:620:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:620:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:620:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:620:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:620:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:620:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:620:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:620:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:620:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:620:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:620:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:620:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:620:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:620:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:620:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:620:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:620:EDES NPP MS")
  field(INPB, "QUAD:LTUH:620:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:640:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:640:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:640:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:640:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:640:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:640:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:640:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:640:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:640:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:640:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:640:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:640:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:640:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:640:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:640:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:640:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:640:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:640:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:640:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:640:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:640:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:640:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:640:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:640:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:640:BMAX")
  field(DOL2, "QUAD:LTUH:640:BMAX")
  field(DOL3, "QUAD:LTUH:640:BMAX")
  field(DOL4, "QUAD:LTUH:640:BMIN")
  field(DOL5, "QUAD:LTUH:640:BMIN")
  field(DOL6, "QUAD:LTUH:640:BMIN")
  field(LNK1, "QUAD:LTUH:640:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:640:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:640:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:640:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:640:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:640:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:640:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:640:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:640:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:640:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:640:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:640:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:640:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:640:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:640:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:640:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:640:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:640:EDES NPP MS")
  field(INPB, "QUAD:LTUH:640:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:660:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:660:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:660:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:660:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:660:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:660:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:660:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:660:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:660:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:660:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:660:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:660:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:660:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:660:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:660:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:660:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:660:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:660:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:660:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:660:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:660:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:660:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:660:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:660:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:660:BMAX")
  field(DOL2, "QUAD:LTUH:660:BMAX")
  field(DOL3, "QUAD:LTUH:660:BMAX")
  field(DOL4, "QUAD:LTUH:660:BMIN")
  field(DOL5, "QUAD:LTUH:660:BMIN")
  field(DOL6, "QUAD:LTUH:660:BMIN")
  field(LNK1, "QUAD:LTUH:660:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:660:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:660:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:660:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:660:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:660:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:660:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:660:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:660:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:660:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:660:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:660:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:660:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:660:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:660:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:660:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:660:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:660:EDES NPP MS")
  field(INPB, "QUAD:LTUH:660:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:665:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:665:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:665:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:665:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:665:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:665:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:665:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:665:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:665:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:665:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:665:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:665:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:665:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:665:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:665:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:665:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:665:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:665:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:665:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:665:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:665:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:665:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:665:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:665:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:665:BMAX")
  field(DOL2, "QUAD:LTUH:665:BMAX")
  field(DOL3, "QUAD:LTUH:665:BMAX")
  field(DOL4, "QUAD:LTUH:665:BMIN")
  field(DOL5, "QUAD:LTUH:665:BMIN")
  field(DOL6, "QUAD:LTUH:665:BMIN")
  field(LNK1, "QUAD:LTUH:665:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:665:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:665:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:665:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:665:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:665:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:665:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:665:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:665:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:665:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:665:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:665:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:665:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:665:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:665:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:665:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:665:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:665:EDES NPP MS")
  field(INPB, "QUAD:LTUH:665:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:680:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:680:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:680:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:680:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:680:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:680:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:680:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:680:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:680:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:680:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:680:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:680:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:680:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:680:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:680:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:680:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:680:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:680:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:680:BMAX")
  field(DOL2, "QUAD:LTUH:680:BMAX")
  field(DOL3, "QUAD:LTUH:680:BMAX")
  field(DOL4, "QUAD:LTUH:680:BMIN")
  field(DOL5, "QUAD:LTUH:680:BMIN")
  field(DOL6, "QUAD:LTUH:680:BMIN")
  field(LNK1, "QUAD:LTUH:680:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:680:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:680:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:680:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:680:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:680:EDES NPP MS")
  field(INPB, "QUAD:LTUH:680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:720:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:720:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:720:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:720:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:720:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:720:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:720:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:720:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:720:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:720:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:720:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:720:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:720:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:720:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:720:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:720:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:720:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:720:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:720:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:720:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:720:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:720:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:720:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:720:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:720:BMAX")
  field(DOL2, "QUAD:LTUH:720:BMAX")
  field(DOL3, "QUAD:LTUH:720:BMAX")
  field(DOL4, "QUAD:LTUH:720:BMIN")
  field(DOL5, "QUAD:LTUH:720:BMIN")
  field(DOL6, "QUAD:LTUH:720:BMIN")
  field(LNK1, "QUAD:LTUH:720:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:720:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:720:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:720:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:720:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:720:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:720:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:720:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:720:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:720:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:720:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:720:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:720:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:720:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:720:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:720:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:720:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:720:EDES NPP MS")
  field(INPB, "QUAD:LTUH:720:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:820:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:820:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:820:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:820:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:820:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:820:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:820:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:820:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:820:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:820:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:820:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:820:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:820:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:820:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:820:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:820:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:820:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:820:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:820:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:820:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:820:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:820:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:820:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:820:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:820:BMAX")
  field(DOL2, "QUAD:LTUH:820:BMAX")
  field(DOL3, "QUAD:LTUH:820:BMAX")
  field(DOL4, "QUAD:LTUH:820:BMIN")
  field(DOL5, "QUAD:LTUH:820:BMIN")
  field(DOL6, "QUAD:LTUH:820:BMIN")
  field(LNK1, "QUAD:LTUH:820:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:820:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:820:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:820:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:820:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:820:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:820:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:820:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:820:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:820:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:820:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:820:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:820:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:820:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:820:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:820:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:820:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:820:EDES NPP MS")
  field(INPB, "QUAD:LTUH:820:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:840:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:840:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:840:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:840:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:840:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:840:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:840:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:840:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:840:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:840:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:840:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:840:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:840:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:840:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:840:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:840:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:840:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:840:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:840:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:840:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:840:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:840:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:840:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:840:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:840:BMAX")
  field(DOL2, "QUAD:LTUH:840:BMAX")
  field(DOL3, "QUAD:LTUH:840:BMAX")
  field(DOL4, "QUAD:LTUH:840:BMIN")
  field(DOL5, "QUAD:LTUH:840:BMIN")
  field(DOL6, "QUAD:LTUH:840:BMIN")
  field(LNK1, "QUAD:LTUH:840:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:840:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:840:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:840:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:840:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:840:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:840:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:840:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:840:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:840:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:840:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:840:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:840:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:840:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:840:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:840:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:840:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:840:EDES NPP MS")
  field(INPB, "QUAD:LTUH:840:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:860:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:860:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:860:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:860:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:860:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:860:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:860:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:860:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:860:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:860:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:860:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:860:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:860:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:860:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:860:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:860:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:860:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:860:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:860:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:860:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:860:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:860:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:860:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:860:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:860:BMAX")
  field(DOL2, "QUAD:LTUH:860:BMAX")
  field(DOL3, "QUAD:LTUH:860:BMAX")
  field(DOL4, "QUAD:LTUH:860:BMIN")
  field(DOL5, "QUAD:LTUH:860:BMIN")
  field(DOL6, "QUAD:LTUH:860:BMIN")
  field(LNK1, "QUAD:LTUH:860:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:860:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:860:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:860:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:860:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:860:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:860:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:860:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:860:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:860:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:860:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:860:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:860:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:860:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:860:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:860:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:860:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:860:EDES NPP MS")
  field(INPB, "QUAD:LTUH:860:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:880:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:880:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:880:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:880:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:880:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:880:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:880:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:880:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:880:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:880:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:880:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:880:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:880:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:880:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:880:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:880:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:880:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:880:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:880:BMAX")
  field(DOL2, "QUAD:LTUH:880:BMAX")
  field(DOL3, "QUAD:LTUH:880:BMAX")
  field(DOL4, "QUAD:LTUH:880:BMIN")
  field(DOL5, "QUAD:LTUH:880:BMIN")
  field(DOL6, "QUAD:LTUH:880:BMIN")
  field(LNK1, "QUAD:LTUH:880:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:880:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:880:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:880:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:880:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUH:880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:880:EDES NPP MS")
  field(INPB, "QUAD:LTUH:880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:115:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:115:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:115:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:115:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:115:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:115:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:115:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:115:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:115:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:115:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:115:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:115:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:115:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:115:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:115:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:115:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:115:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:115:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:115:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:115:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:115:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:115:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:115:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:115:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:115:BMAX")
  field(DOL2, "XCOR:LTUH:115:BMAX")
  field(DOL3, "XCOR:LTUH:115:BMAX")
  field(DOL4, "XCOR:LTUH:115:BMIN")
  field(DOL5, "XCOR:LTUH:115:BMIN")
  field(DOL6, "XCOR:LTUH:115:BMIN")
  field(LNK1, "XCOR:LTUH:115:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:115:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:115:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:115:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:115:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:115:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:115:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:115:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:115:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:115:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:115:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:115:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:115:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:115:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:115:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:115:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:115:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:115:EDES NPP MS")
  field(INPB, "XCOR:LTUH:115:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:144:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:144:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:144:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:144:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:144:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:144:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:144:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:144:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:144:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:144:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:144:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:144:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:144:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:144:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:144:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:144:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:144:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:144:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:144:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:144:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:144:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:144:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:144:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:144:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:144:BMAX")
  field(DOL2, "XCOR:LTUH:144:BMAX")
  field(DOL3, "XCOR:LTUH:144:BMAX")
  field(DOL4, "XCOR:LTUH:144:BMIN")
  field(DOL5, "XCOR:LTUH:144:BMIN")
  field(DOL6, "XCOR:LTUH:144:BMIN")
  field(LNK1, "XCOR:LTUH:144:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:144:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:144:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:144:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:144:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:144:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:144:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:144:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:144:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:144:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:144:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:144:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:144:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:144:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:144:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:144:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:144:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:144:EDES NPP MS")
  field(INPB, "XCOR:LTUH:144:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:178:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:178:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:178:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:178:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:178:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:178:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:178:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:178:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:178:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:178:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:178:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:178:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:178:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:178:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:178:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:178:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:178:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:178:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:178:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:178:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:178:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:178:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:178:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:178:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:178:BMAX")
  field(DOL2, "XCOR:LTUH:178:BMAX")
  field(DOL3, "XCOR:LTUH:178:BMAX")
  field(DOL4, "XCOR:LTUH:178:BMIN")
  field(DOL5, "XCOR:LTUH:178:BMIN")
  field(DOL6, "XCOR:LTUH:178:BMIN")
  field(LNK1, "XCOR:LTUH:178:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:178:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:178:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:178:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:178:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:178:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:178:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:178:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:178:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:178:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:178:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:178:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:178:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:178:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:178:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:178:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:178:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:178:EDES NPP MS")
  field(INPB, "XCOR:LTUH:178:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:248:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:248:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:248:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:248:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:248:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:248:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:248:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:248:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:248:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:248:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:248:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:248:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:248:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:248:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:248:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:248:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:248:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:248:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:248:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:248:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:248:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:248:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:248:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:248:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:248:BMAX")
  field(DOL2, "XCOR:LTUH:248:BMAX")
  field(DOL3, "XCOR:LTUH:248:BMAX")
  field(DOL4, "XCOR:LTUH:248:BMIN")
  field(DOL5, "XCOR:LTUH:248:BMIN")
  field(DOL6, "XCOR:LTUH:248:BMIN")
  field(LNK1, "XCOR:LTUH:248:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:248:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:248:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:248:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:248:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:248:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:248:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:248:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:248:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:248:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:248:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:248:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:248:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:248:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:248:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:248:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:248:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:248:EDES NPP MS")
  field(INPB, "XCOR:LTUH:248:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:288:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:288:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:288:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:288:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:288:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:288:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:288:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:288:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:288:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:288:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:288:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:288:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:288:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:288:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:288:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:288:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:288:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:288:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:288:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:288:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:288:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:288:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:288:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:288:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:288:BMAX")
  field(DOL2, "XCOR:LTUH:288:BMAX")
  field(DOL3, "XCOR:LTUH:288:BMAX")
  field(DOL4, "XCOR:LTUH:288:BMIN")
  field(DOL5, "XCOR:LTUH:288:BMIN")
  field(DOL6, "XCOR:LTUH:288:BMIN")
  field(LNK1, "XCOR:LTUH:288:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:288:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:288:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:288:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:288:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:288:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:288:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:288:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:288:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:288:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:288:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:288:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:288:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:288:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:288:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:288:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:288:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:288:EDES NPP MS")
  field(INPB, "XCOR:LTUH:288:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:348:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:348:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:348:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:348:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:348:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:348:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:348:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:348:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:348:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:348:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:348:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:348:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:348:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:348:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:348:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:348:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:348:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:348:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:348:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:348:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:348:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:348:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:348:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:348:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:348:BMAX")
  field(DOL2, "XCOR:LTUH:348:BMAX")
  field(DOL3, "XCOR:LTUH:348:BMAX")
  field(DOL4, "XCOR:LTUH:348:BMIN")
  field(DOL5, "XCOR:LTUH:348:BMIN")
  field(DOL6, "XCOR:LTUH:348:BMIN")
  field(LNK1, "XCOR:LTUH:348:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:348:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:348:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:348:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:348:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:348:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:348:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:348:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:348:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:348:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:348:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:348:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:348:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:348:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:348:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:348:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:348:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:348:EDES NPP MS")
  field(INPB, "XCOR:LTUH:348:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:388:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:388:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:388:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:388:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:388:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:388:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:388:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:388:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:388:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:388:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:388:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:388:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:388:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:388:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:388:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:388:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:388:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:388:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:388:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:388:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:388:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:388:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:388:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:388:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:388:BMAX")
  field(DOL2, "XCOR:LTUH:388:BMAX")
  field(DOL3, "XCOR:LTUH:388:BMAX")
  field(DOL4, "XCOR:LTUH:388:BMIN")
  field(DOL5, "XCOR:LTUH:388:BMIN")
  field(DOL6, "XCOR:LTUH:388:BMIN")
  field(LNK1, "XCOR:LTUH:388:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:388:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:388:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:388:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:388:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:388:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:388:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:388:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:388:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:388:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:388:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:388:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:388:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:388:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:388:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:388:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:388:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:388:EDES NPP MS")
  field(INPB, "XCOR:LTUH:388:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:448:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:448:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:448:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:448:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:448:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:448:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:448:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:448:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:448:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:448:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:448:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:448:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:448:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:448:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:448:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:448:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:448:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:448:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:448:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:448:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:448:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:448:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:448:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:448:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:448:BMAX")
  field(DOL2, "XCOR:LTUH:448:BMAX")
  field(DOL3, "XCOR:LTUH:448:BMAX")
  field(DOL4, "XCOR:LTUH:448:BMIN")
  field(DOL5, "XCOR:LTUH:448:BMIN")
  field(DOL6, "XCOR:LTUH:448:BMIN")
  field(LNK1, "XCOR:LTUH:448:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:448:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:448:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:448:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:448:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:448:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:448:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:448:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:448:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:448:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:448:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:448:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:448:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:448:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:448:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:448:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:448:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:448:EDES NPP MS")
  field(INPB, "XCOR:LTUH:448:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:488:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:488:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:488:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:488:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:488:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:488:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:488:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:488:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:488:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:488:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:488:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:488:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:488:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:488:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:488:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:488:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:488:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:488:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:488:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:488:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:488:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:488:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:488:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:488:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:488:BMAX")
  field(DOL2, "XCOR:LTUH:488:BMAX")
  field(DOL3, "XCOR:LTUH:488:BMAX")
  field(DOL4, "XCOR:LTUH:488:BMIN")
  field(DOL5, "XCOR:LTUH:488:BMIN")
  field(DOL6, "XCOR:LTUH:488:BMIN")
  field(LNK1, "XCOR:LTUH:488:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:488:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:488:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:488:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:488:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:488:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:488:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:488:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:488:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:488:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:488:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:488:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:488:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:488:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:488:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:488:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:488:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:488:EDES NPP MS")
  field(INPB, "XCOR:LTUH:488:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:588:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:588:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:588:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:588:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:588:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:588:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:588:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:588:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:588:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:588:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:588:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:588:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:588:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:588:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:588:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:588:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:588:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:588:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:588:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:588:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:588:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:588:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:588:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:588:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:588:BMAX")
  field(DOL2, "XCOR:LTUH:588:BMAX")
  field(DOL3, "XCOR:LTUH:588:BMAX")
  field(DOL4, "XCOR:LTUH:588:BMIN")
  field(DOL5, "XCOR:LTUH:588:BMIN")
  field(DOL6, "XCOR:LTUH:588:BMIN")
  field(LNK1, "XCOR:LTUH:588:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:588:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:588:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:588:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:588:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:588:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:588:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:588:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:588:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:588:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:588:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:588:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:588:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:588:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:588:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:588:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:588:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:588:EDES NPP MS")
  field(INPB, "XCOR:LTUH:588:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:558:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:558:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:558:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:558:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:558:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:558:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:558:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:558:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:558:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:558:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:558:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:558:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:558:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:558:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:558:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:558:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:558:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:558:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:558:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:558:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:558:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:558:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:558:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:558:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:558:BMAX")
  field(DOL2, "XCOR:LTUH:558:BMAX")
  field(DOL3, "XCOR:LTUH:558:BMAX")
  field(DOL4, "XCOR:LTUH:558:BMIN")
  field(DOL5, "XCOR:LTUH:558:BMIN")
  field(DOL6, "XCOR:LTUH:558:BMIN")
  field(LNK1, "XCOR:LTUH:558:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:558:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:558:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:558:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:558:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:558:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:558:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:558:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:558:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:558:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:558:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:558:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:558:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:558:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:558:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:558:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:558:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:558:EDES NPP MS")
  field(INPB, "XCOR:LTUH:558:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:642:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:642:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:642:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:642:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:642:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:642:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:642:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:642:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:642:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:642:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:642:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:642:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:642:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:642:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:642:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:642:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:642:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:642:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:642:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:642:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:642:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:642:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:642:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:642:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:642:BMAX")
  field(DOL2, "XCOR:LTUH:642:BMAX")
  field(DOL3, "XCOR:LTUH:642:BMAX")
  field(DOL4, "XCOR:LTUH:642:BMIN")
  field(DOL5, "XCOR:LTUH:642:BMIN")
  field(DOL6, "XCOR:LTUH:642:BMIN")
  field(LNK1, "XCOR:LTUH:642:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:642:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:642:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:642:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:642:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:642:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:642:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:642:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:642:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:642:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:642:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:642:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:642:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:642:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:642:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:642:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:642:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:642:EDES NPP MS")
  field(INPB, "XCOR:LTUH:642:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:678:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:678:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:678:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:678:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:678:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:678:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:678:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:678:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:678:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:678:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:678:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:678:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:678:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:678:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:678:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:678:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:678:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:678:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:678:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:678:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:678:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:678:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:678:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:678:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:678:BMAX")
  field(DOL2, "XCOR:LTUH:678:BMAX")
  field(DOL3, "XCOR:LTUH:678:BMAX")
  field(DOL4, "XCOR:LTUH:678:BMIN")
  field(DOL5, "XCOR:LTUH:678:BMIN")
  field(DOL6, "XCOR:LTUH:678:BMIN")
  field(LNK1, "XCOR:LTUH:678:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:678:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:678:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:678:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:678:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:678:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:678:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:678:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:678:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:678:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:678:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:678:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:678:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:678:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:678:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:678:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:678:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:678:EDES NPP MS")
  field(INPB, "XCOR:LTUH:678:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:718:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:718:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:718:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:718:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:718:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:718:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:718:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:718:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:718:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:718:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:718:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:718:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:718:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:718:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:718:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:718:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:718:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:718:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:718:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:718:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:718:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:718:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:718:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:718:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:718:BMAX")
  field(DOL2, "XCOR:LTUH:718:BMAX")
  field(DOL3, "XCOR:LTUH:718:BMAX")
  field(DOL4, "XCOR:LTUH:718:BMIN")
  field(DOL5, "XCOR:LTUH:718:BMIN")
  field(DOL6, "XCOR:LTUH:718:BMIN")
  field(LNK1, "XCOR:LTUH:718:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:718:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:718:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:718:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:718:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:718:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:718:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:718:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:718:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:718:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:718:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:718:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:718:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:718:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:718:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:718:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:718:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:718:EDES NPP MS")
  field(INPB, "XCOR:LTUH:718:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:738:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:738:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:738:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:738:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:738:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:738:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:738:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:738:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:738:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:738:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:738:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:738:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:738:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:738:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:738:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:738:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:738:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:738:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:738:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:738:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:738:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:738:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:738:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:738:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:738:BMAX")
  field(DOL2, "XCOR:LTUH:738:BMAX")
  field(DOL3, "XCOR:LTUH:738:BMAX")
  field(DOL4, "XCOR:LTUH:738:BMIN")
  field(DOL5, "XCOR:LTUH:738:BMIN")
  field(DOL6, "XCOR:LTUH:738:BMIN")
  field(LNK1, "XCOR:LTUH:738:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:738:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:738:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:738:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:738:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:738:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:738:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:738:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:738:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:738:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:738:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:738:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:738:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:738:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:738:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:738:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:738:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:738:EDES NPP MS")
  field(INPB, "XCOR:LTUH:738:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:758:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:758:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:758:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:758:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:758:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:758:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:758:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:758:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:758:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:758:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:758:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:758:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:758:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:758:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:758:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:758:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:758:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:758:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:758:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:758:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:758:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:758:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:758:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:758:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:758:BMAX")
  field(DOL2, "XCOR:LTUH:758:BMAX")
  field(DOL3, "XCOR:LTUH:758:BMAX")
  field(DOL4, "XCOR:LTUH:758:BMIN")
  field(DOL5, "XCOR:LTUH:758:BMIN")
  field(DOL6, "XCOR:LTUH:758:BMIN")
  field(LNK1, "XCOR:LTUH:758:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:758:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:758:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:758:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:758:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:758:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:758:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:758:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:758:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:758:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:758:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:758:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:758:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:758:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:758:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:758:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:758:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:758:EDES NPP MS")
  field(INPB, "XCOR:LTUH:758:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:818:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:818:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:818:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:818:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:818:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:818:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:818:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:818:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:818:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:818:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:818:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:818:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:818:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:818:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:818:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:818:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:818:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:818:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:818:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:818:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:818:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:818:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:818:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:818:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:818:BMAX")
  field(DOL2, "XCOR:LTUH:818:BMAX")
  field(DOL3, "XCOR:LTUH:818:BMAX")
  field(DOL4, "XCOR:LTUH:818:BMIN")
  field(DOL5, "XCOR:LTUH:818:BMIN")
  field(DOL6, "XCOR:LTUH:818:BMIN")
  field(LNK1, "XCOR:LTUH:818:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:818:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:818:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:818:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:818:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:818:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:818:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:818:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:818:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:818:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:818:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:818:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:818:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:818:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:818:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:818:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:818:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:818:EDES NPP MS")
  field(INPB, "XCOR:LTUH:818:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUH:858:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUH:858:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUH:858:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUH:858:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUH:858:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUH:858:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUH:858:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUH:858:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUH:858:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUH:858:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUH:858:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUH:858:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUH:858:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUH:858:EDES.PROC PP")
    field(LNK2, "XCOR:LTUH:858:EACT.PROC PP")
    field(LNK3, "XCOR:LTUH:858:EERR.DISA PP")
    field(LNK4, "XCOR:LTUH:858:ECON.PROC PP")
    field(LNK5, "XCOR:LTUH:858:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUH:858:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUH:858:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUH:858:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUH:858:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUH:858:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUH:858:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUH:858:BMAX")
  field(DOL2, "XCOR:LTUH:858:BMAX")
  field(DOL3, "XCOR:LTUH:858:BMAX")
  field(DOL4, "XCOR:LTUH:858:BMIN")
  field(DOL5, "XCOR:LTUH:858:BMIN")
  field(DOL6, "XCOR:LTUH:858:BMIN")
  field(LNK1, "XCOR:LTUH:858:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUH:858:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUH:858:BLEM.HOPR")
  field(LNK4, "XCOR:LTUH:858:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUH:858:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUH:858:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:858:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUH:858:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUH:858:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUH:858:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUH:858:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:858:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:858:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:858:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUH:858:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUH:858:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUH:858:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUH:858:EDES NPP MS")
  field(INPB, "XCOR:LTUH:858:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:105:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:105:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:105:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:105:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:105:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:105:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:105:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:105:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:105:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:105:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:105:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:105:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:105:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:105:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:105:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:105:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:105:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:105:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:105:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:105:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:105:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:105:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:105:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:105:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:105:BMAX")
  field(DOL2, "YCOR:LTUH:105:BMAX")
  field(DOL3, "YCOR:LTUH:105:BMAX")
  field(DOL4, "YCOR:LTUH:105:BMIN")
  field(DOL5, "YCOR:LTUH:105:BMIN")
  field(DOL6, "YCOR:LTUH:105:BMIN")
  field(LNK1, "YCOR:LTUH:105:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:105:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:105:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:105:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:105:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:105:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:105:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:105:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:105:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:105:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:105:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:105:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:105:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:105:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:105:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:105:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:105:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:105:EDES NPP MS")
  field(INPB, "YCOR:LTUH:105:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:133:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:133:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:133:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:133:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:133:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:133:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:133:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:133:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:133:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:133:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:133:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:133:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:133:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:133:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:133:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:133:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:133:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:133:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:133:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:133:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:133:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:133:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:133:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:133:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:133:BMAX")
  field(DOL2, "YCOR:LTUH:133:BMAX")
  field(DOL3, "YCOR:LTUH:133:BMAX")
  field(DOL4, "YCOR:LTUH:133:BMIN")
  field(DOL5, "YCOR:LTUH:133:BMIN")
  field(DOL6, "YCOR:LTUH:133:BMIN")
  field(LNK1, "YCOR:LTUH:133:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:133:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:133:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:133:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:133:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:133:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:133:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:133:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:133:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:133:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:133:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:133:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:133:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:133:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:133:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:133:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:133:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:133:EDES NPP MS")
  field(INPB, "YCOR:LTUH:133:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:171:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:171:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:171:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:171:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:171:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:171:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:171:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:171:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:171:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:171:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:171:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:171:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:171:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:171:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:171:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:171:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:171:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:171:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:171:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:171:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:171:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:171:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:171:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:171:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:171:BMAX")
  field(DOL2, "YCOR:LTUH:171:BMAX")
  field(DOL3, "YCOR:LTUH:171:BMAX")
  field(DOL4, "YCOR:LTUH:171:BMIN")
  field(DOL5, "YCOR:LTUH:171:BMIN")
  field(DOL6, "YCOR:LTUH:171:BMIN")
  field(LNK1, "YCOR:LTUH:171:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:171:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:171:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:171:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:171:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:171:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:171:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:171:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:171:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:171:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:171:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:171:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:171:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:171:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:171:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:171:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:171:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:171:EDES NPP MS")
  field(INPB, "YCOR:LTUH:171:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:185:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:185:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:185:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:185:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:185:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:185:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:185:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:185:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:185:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:185:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:185:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:185:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:185:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:185:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:185:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:185:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:185:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:185:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:185:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:185:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:185:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:185:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:185:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:185:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:185:BMAX")
  field(DOL2, "YCOR:LTUH:185:BMAX")
  field(DOL3, "YCOR:LTUH:185:BMAX")
  field(DOL4, "YCOR:LTUH:185:BMIN")
  field(DOL5, "YCOR:LTUH:185:BMIN")
  field(DOL6, "YCOR:LTUH:185:BMIN")
  field(LNK1, "YCOR:LTUH:185:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:185:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:185:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:185:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:185:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:185:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:185:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:185:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:185:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:185:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:185:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:185:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:185:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:185:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:185:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:185:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:185:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:185:EDES NPP MS")
  field(INPB, "YCOR:LTUH:185:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:253:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:253:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:253:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:253:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:253:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:253:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:253:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:253:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:253:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:253:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:253:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:253:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:253:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:253:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:253:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:253:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:253:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:253:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:253:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:253:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:253:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:253:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:253:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:253:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:253:BMAX")
  field(DOL2, "YCOR:LTUH:253:BMAX")
  field(DOL3, "YCOR:LTUH:253:BMAX")
  field(DOL4, "YCOR:LTUH:253:BMIN")
  field(DOL5, "YCOR:LTUH:253:BMIN")
  field(DOL6, "YCOR:LTUH:253:BMIN")
  field(LNK1, "YCOR:LTUH:253:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:253:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:253:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:253:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:253:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:253:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:253:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:253:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:253:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:253:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:253:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:253:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:253:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:253:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:253:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:253:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:253:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:253:EDES NPP MS")
  field(INPB, "YCOR:LTUH:253:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:293:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:293:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:293:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:293:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:293:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:293:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:293:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:293:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:293:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:293:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:293:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:293:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:293:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:293:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:293:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:293:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:293:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:293:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:293:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:293:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:293:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:293:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:293:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:293:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:293:BMAX")
  field(DOL2, "YCOR:LTUH:293:BMAX")
  field(DOL3, "YCOR:LTUH:293:BMAX")
  field(DOL4, "YCOR:LTUH:293:BMIN")
  field(DOL5, "YCOR:LTUH:293:BMIN")
  field(DOL6, "YCOR:LTUH:293:BMIN")
  field(LNK1, "YCOR:LTUH:293:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:293:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:293:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:293:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:293:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:293:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:293:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:293:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:293:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:293:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:293:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:293:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:293:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:293:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:293:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:293:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:293:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:293:EDES NPP MS")
  field(INPB, "YCOR:LTUH:293:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:353:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:353:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:353:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:353:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:353:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:353:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:353:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:353:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:353:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:353:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:353:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:353:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:353:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:353:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:353:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:353:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:353:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:353:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:353:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:353:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:353:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:353:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:353:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:353:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:353:BMAX")
  field(DOL2, "YCOR:LTUH:353:BMAX")
  field(DOL3, "YCOR:LTUH:353:BMAX")
  field(DOL4, "YCOR:LTUH:353:BMIN")
  field(DOL5, "YCOR:LTUH:353:BMIN")
  field(DOL6, "YCOR:LTUH:353:BMIN")
  field(LNK1, "YCOR:LTUH:353:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:353:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:353:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:353:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:353:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:353:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:353:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:353:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:353:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:353:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:353:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:353:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:353:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:353:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:353:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:353:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:353:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:353:EDES NPP MS")
  field(INPB, "YCOR:LTUH:353:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:383:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:383:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:383:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:383:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:383:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:383:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:383:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:383:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:383:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:383:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:383:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:383:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:383:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:383:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:383:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:383:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:383:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:383:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:383:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:383:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:383:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:383:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:383:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:383:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:383:BMAX")
  field(DOL2, "YCOR:LTUH:383:BMAX")
  field(DOL3, "YCOR:LTUH:383:BMAX")
  field(DOL4, "YCOR:LTUH:383:BMIN")
  field(DOL5, "YCOR:LTUH:383:BMIN")
  field(DOL6, "YCOR:LTUH:383:BMIN")
  field(LNK1, "YCOR:LTUH:383:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:383:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:383:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:383:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:383:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:383:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:383:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:383:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:383:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:383:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:383:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:383:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:383:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:383:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:383:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:383:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:383:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:383:EDES NPP MS")
  field(INPB, "YCOR:LTUH:383:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:453:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:453:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:453:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:453:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:453:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:453:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:453:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:453:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:453:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:453:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:453:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:453:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:453:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:453:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:453:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:453:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:453:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:453:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:453:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:453:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:453:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:453:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:453:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:453:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:453:BMAX")
  field(DOL2, "YCOR:LTUH:453:BMAX")
  field(DOL3, "YCOR:LTUH:453:BMAX")
  field(DOL4, "YCOR:LTUH:453:BMIN")
  field(DOL5, "YCOR:LTUH:453:BMIN")
  field(DOL6, "YCOR:LTUH:453:BMIN")
  field(LNK1, "YCOR:LTUH:453:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:453:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:453:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:453:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:453:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:453:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:453:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:453:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:453:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:453:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:453:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:453:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:453:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:453:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:453:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:453:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:453:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:453:EDES NPP MS")
  field(INPB, "YCOR:LTUH:453:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:493:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:493:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:493:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:493:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:493:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:493:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:493:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:493:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:493:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:493:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:493:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:493:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:493:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:493:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:493:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:493:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:493:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:493:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:493:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:493:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:493:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:493:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:493:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:493:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:493:BMAX")
  field(DOL2, "YCOR:LTUH:493:BMAX")
  field(DOL3, "YCOR:LTUH:493:BMAX")
  field(DOL4, "YCOR:LTUH:493:BMIN")
  field(DOL5, "YCOR:LTUH:493:BMIN")
  field(DOL6, "YCOR:LTUH:493:BMIN")
  field(LNK1, "YCOR:LTUH:493:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:493:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:493:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:493:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:493:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:493:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:493:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:493:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:493:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:493:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:493:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:493:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:493:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:493:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:493:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:493:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:493:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:493:EDES NPP MS")
  field(INPB, "YCOR:LTUH:493:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:563:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:563:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:563:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:563:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:563:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:563:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:563:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:563:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:563:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:563:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:563:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:563:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:563:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:563:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:563:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:563:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:563:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:563:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:563:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:563:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:563:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:563:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:563:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:563:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:563:BMAX")
  field(DOL2, "YCOR:LTUH:563:BMAX")
  field(DOL3, "YCOR:LTUH:563:BMAX")
  field(DOL4, "YCOR:LTUH:563:BMIN")
  field(DOL5, "YCOR:LTUH:563:BMIN")
  field(DOL6, "YCOR:LTUH:563:BMIN")
  field(LNK1, "YCOR:LTUH:563:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:563:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:563:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:563:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:563:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:563:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:563:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:563:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:563:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:563:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:563:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:563:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:563:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:563:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:563:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:563:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:563:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:563:EDES NPP MS")
  field(INPB, "YCOR:LTUH:563:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:593:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:593:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:593:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:593:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:593:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:593:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:593:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:593:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:593:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:593:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:593:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:593:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:593:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:593:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:593:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:593:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:593:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:593:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:593:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:593:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:593:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:593:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:593:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:593:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:593:BMAX")
  field(DOL2, "YCOR:LTUH:593:BMAX")
  field(DOL3, "YCOR:LTUH:593:BMAX")
  field(DOL4, "YCOR:LTUH:593:BMIN")
  field(DOL5, "YCOR:LTUH:593:BMIN")
  field(DOL6, "YCOR:LTUH:593:BMIN")
  field(LNK1, "YCOR:LTUH:593:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:593:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:593:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:593:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:593:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:593:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:593:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:593:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:593:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:593:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:593:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:593:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:593:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:593:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:593:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:593:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:593:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:593:EDES NPP MS")
  field(INPB, "YCOR:LTUH:593:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:611:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:611:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:611:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:611:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:611:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:611:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:611:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:611:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:611:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:611:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:611:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:611:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:611:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:611:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:611:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:611:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:611:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:611:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:611:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:611:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:611:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:611:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:611:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:611:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:611:BMAX")
  field(DOL2, "YCOR:LTUH:611:BMAX")
  field(DOL3, "YCOR:LTUH:611:BMAX")
  field(DOL4, "YCOR:LTUH:611:BMIN")
  field(DOL5, "YCOR:LTUH:611:BMIN")
  field(DOL6, "YCOR:LTUH:611:BMIN")
  field(LNK1, "YCOR:LTUH:611:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:611:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:611:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:611:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:611:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:611:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:611:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:611:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:611:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:611:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:611:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:611:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:611:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:611:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:611:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:611:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:611:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:611:EDES NPP MS")
  field(INPB, "YCOR:LTUH:611:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:657:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:657:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:657:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:657:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:657:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:657:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:657:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:657:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:657:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:657:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:657:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:657:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:657:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:657:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:657:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:657:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:657:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:657:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:657:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:657:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:657:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:657:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:657:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:657:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:657:BMAX")
  field(DOL2, "YCOR:LTUH:657:BMAX")
  field(DOL3, "YCOR:LTUH:657:BMAX")
  field(DOL4, "YCOR:LTUH:657:BMIN")
  field(DOL5, "YCOR:LTUH:657:BMIN")
  field(DOL6, "YCOR:LTUH:657:BMIN")
  field(LNK1, "YCOR:LTUH:657:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:657:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:657:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:657:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:657:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:657:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:657:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:657:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:657:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:657:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:657:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:657:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:657:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:657:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:657:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:657:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:657:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:657:EDES NPP MS")
  field(INPB, "YCOR:LTUH:657:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:727:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:727:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:727:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:727:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:727:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:727:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:727:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:727:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:727:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:727:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:727:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:727:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:727:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:727:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:727:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:727:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:727:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:727:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:727:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:727:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:727:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:727:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:727:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:727:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:727:BMAX")
  field(DOL2, "YCOR:LTUH:727:BMAX")
  field(DOL3, "YCOR:LTUH:727:BMAX")
  field(DOL4, "YCOR:LTUH:727:BMIN")
  field(DOL5, "YCOR:LTUH:727:BMIN")
  field(DOL6, "YCOR:LTUH:727:BMIN")
  field(LNK1, "YCOR:LTUH:727:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:727:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:727:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:727:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:727:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:727:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:727:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:727:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:727:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:727:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:727:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:727:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:727:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:727:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:727:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:727:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:727:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:727:EDES NPP MS")
  field(INPB, "YCOR:LTUH:727:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:747:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:747:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:747:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:747:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:747:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:747:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:747:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:747:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:747:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:747:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:747:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:747:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:747:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:747:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:747:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:747:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:747:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:747:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:747:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:747:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:747:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:747:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:747:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:747:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:747:BMAX")
  field(DOL2, "YCOR:LTUH:747:BMAX")
  field(DOL3, "YCOR:LTUH:747:BMAX")
  field(DOL4, "YCOR:LTUH:747:BMIN")
  field(DOL5, "YCOR:LTUH:747:BMIN")
  field(DOL6, "YCOR:LTUH:747:BMIN")
  field(LNK1, "YCOR:LTUH:747:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:747:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:747:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:747:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:747:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:747:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:747:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:747:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:747:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:747:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:747:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:747:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:747:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:747:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:747:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:747:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:747:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:747:EDES NPP MS")
  field(INPB, "YCOR:LTUH:747:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:767:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:767:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:767:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:767:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:767:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:767:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:767:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:767:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:767:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:767:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:767:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:767:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:767:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:767:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:767:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:767:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:767:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:767:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:767:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:767:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:767:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:767:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:767:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:767:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:767:BMAX")
  field(DOL2, "YCOR:LTUH:767:BMAX")
  field(DOL3, "YCOR:LTUH:767:BMAX")
  field(DOL4, "YCOR:LTUH:767:BMIN")
  field(DOL5, "YCOR:LTUH:767:BMIN")
  field(DOL6, "YCOR:LTUH:767:BMIN")
  field(LNK1, "YCOR:LTUH:767:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:767:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:767:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:767:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:767:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:767:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:767:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:767:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:767:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:767:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:767:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:767:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:767:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:767:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:767:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:767:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:767:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:767:EDES NPP MS")
  field(INPB, "YCOR:LTUH:767:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:837:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:837:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:837:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:837:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:837:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:837:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:837:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:837:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:837:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:837:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:837:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:837:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:837:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:837:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:837:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:837:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:837:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:837:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:837:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:837:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:837:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:837:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:837:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:837:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:837:BMAX")
  field(DOL2, "YCOR:LTUH:837:BMAX")
  field(DOL3, "YCOR:LTUH:837:BMAX")
  field(DOL4, "YCOR:LTUH:837:BMIN")
  field(DOL5, "YCOR:LTUH:837:BMIN")
  field(DOL6, "YCOR:LTUH:837:BMIN")
  field(LNK1, "YCOR:LTUH:837:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:837:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:837:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:837:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:837:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:837:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:837:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:837:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:837:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:837:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:837:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:837:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:837:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:837:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:837:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:837:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:837:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:837:EDES NPP MS")
  field(INPB, "YCOR:LTUH:837:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUH:877:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUH:877:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUH:877:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUH:877:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUH:877:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUH:877:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUH:877:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUH:877:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUH:877:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUH:877:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUH:877:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUH:877:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUH:877:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUH:877:EDES.PROC PP")
    field(LNK2, "YCOR:LTUH:877:EACT.PROC PP")
    field(LNK3, "YCOR:LTUH:877:EERR.DISA PP")
    field(LNK4, "YCOR:LTUH:877:ECON.PROC PP")
    field(LNK5, "YCOR:LTUH:877:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUH:877:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUH:877:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUH:877:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUH:877:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUH:877:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUH:877:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUH:877:BMAX")
  field(DOL2, "YCOR:LTUH:877:BMAX")
  field(DOL3, "YCOR:LTUH:877:BMAX")
  field(DOL4, "YCOR:LTUH:877:BMIN")
  field(DOL5, "YCOR:LTUH:877:BMIN")
  field(DOL6, "YCOR:LTUH:877:BMIN")
  field(LNK1, "YCOR:LTUH:877:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUH:877:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUH:877:BLEM.HOPR")
  field(LNK4, "YCOR:LTUH:877:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUH:877:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUH:877:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:877:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUH:877:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUH:877:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUH:877:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUH:877:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:877:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:877:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:877:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUH:877:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUH:877:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUH:877:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUH:877:EDES NPP MS")
  field(INPB, "YCOR:LTUH:877:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LTUS:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "LGPS:LTUS:1:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LTUS:1:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LTUS:1:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LTUS:1:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LTUS:1:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LTUS:1:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LTUS:1:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LTUS:1:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LTUS:1:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LTUS:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LTUS:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LTUS:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LTUS:1:EDES.PROC PP")
    field(LNK2, "LGPS:LTUS:1:EACT.PROC PP")
    field(LNK3, "LGPS:LTUS:1:EERR.DISA PP")
    field(LNK4, "LGPS:LTUS:1:ECON.PROC PP")
    field(LNK5, "LGPS:LTUS:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:LTUS:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:LTUS:1:BLEM.PROC PP")
    field(LNK8, "LGPS:LTUS:1:BMOD.PROC PP")
    field(LNK9, "LGPS:LTUS:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LTUS:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LTUS:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LTUS:1:BMAX")
  field(DOL2, "LGPS:LTUS:1:BMAX")
  field(DOL3, "LGPS:LTUS:1:BMAX")
  field(DOL4, "LGPS:LTUS:1:BMIN")
  field(DOL5, "LGPS:LTUS:1:BMIN")
  field(DOL6, "LGPS:LTUS:1:BMIN")
  field(LNK1, "LGPS:LTUS:1:BMAGX.HOPR")
  field(LNK2, "LGPS:LTUS:1:BMAGY.HOPR")
  field(LNK3, "LGPS:LTUS:1:BLEM.HOPR")
  field(LNK4, "LGPS:LTUS:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LTUS:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LTUS:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUS:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUS:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LTUS:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LTUS:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LTUS:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUS:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUS:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LTUS:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LTUS:1:EDES NPP MS")
  field(INPB, "LGPS:LTUS:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LTUS:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "LGPS:LTUS:2:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LTUS:2:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LTUS:2:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LTUS:2:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LTUS:2:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LTUS:2:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LTUS:2:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LTUS:2:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LTUS:2:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LTUS:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LTUS:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LTUS:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LTUS:2:EDES.PROC PP")
    field(LNK2, "LGPS:LTUS:2:EACT.PROC PP")
    field(LNK3, "LGPS:LTUS:2:EERR.DISA PP")
    field(LNK4, "LGPS:LTUS:2:ECON.PROC PP")
    field(LNK5, "LGPS:LTUS:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:LTUS:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:LTUS:2:BLEM.PROC PP")
    field(LNK8, "LGPS:LTUS:2:BMOD.PROC PP")
    field(LNK9, "LGPS:LTUS:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LTUS:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LTUS:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LTUS:2:BMAX")
  field(DOL2, "LGPS:LTUS:2:BMAX")
  field(DOL3, "LGPS:LTUS:2:BMAX")
  field(DOL4, "LGPS:LTUS:2:BMIN")
  field(DOL5, "LGPS:LTUS:2:BMIN")
  field(DOL6, "LGPS:LTUS:2:BMIN")
  field(LNK1, "LGPS:LTUS:2:BMAGX.HOPR")
  field(LNK2, "LGPS:LTUS:2:BMAGY.HOPR")
  field(LNK3, "LGPS:LTUS:2:BLEM.HOPR")
  field(LNK4, "LGPS:LTUS:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LTUS:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LTUS:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUS:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUS:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LTUS:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LTUS:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LTUS:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUS:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUS:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LTUS:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LTUS:2:EDES NPP MS")
  field(INPB, "LGPS:LTUS:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LTUS:3:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "LGPS:LTUS:3:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LTUS:3:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LTUS:3:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LTUS:3:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LTUS:3:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LTUS:3:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LTUS:3:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LTUS:3:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LTUS:3:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LTUS:3:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LTUS:3:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LTUS:3:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LTUS:3:EDES.PROC PP")
    field(LNK2, "LGPS:LTUS:3:EACT.PROC PP")
    field(LNK3, "LGPS:LTUS:3:EERR.DISA PP")
    field(LNK4, "LGPS:LTUS:3:ECON.PROC PP")
    field(LNK5, "LGPS:LTUS:3:BMAGX.PROC PP")
    field(LNK6, "LGPS:LTUS:3:BMAGY.PROC PP")
    field(LNK7, "LGPS:LTUS:3:BLEM.PROC PP")
    field(LNK8, "LGPS:LTUS:3:BMOD.PROC PP")
    field(LNK9, "LGPS:LTUS:3:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LTUS:3:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LTUS:3:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LTUS:3:BMAX")
  field(DOL2, "LGPS:LTUS:3:BMAX")
  field(DOL3, "LGPS:LTUS:3:BMAX")
  field(DOL4, "LGPS:LTUS:3:BMIN")
  field(DOL5, "LGPS:LTUS:3:BMIN")
  field(DOL6, "LGPS:LTUS:3:BMIN")
  field(LNK1, "LGPS:LTUS:3:BMAGX.HOPR")
  field(LNK2, "LGPS:LTUS:3:BMAGY.HOPR")
  field(LNK3, "LGPS:LTUS:3:BLEM.HOPR")
  field(LNK4, "LGPS:LTUS:3:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LTUS:3:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LTUS:3:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUS:3:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUS:3:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LTUS:3:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LTUS:3:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LTUS:3:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:3:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:3:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUS:3:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:3:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUS:3:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LTUS:3:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LTUS:3:EDES NPP MS")
  field(INPB, "LGPS:LTUS:3:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LTUS:4:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "LGPS:LTUS:4:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LTUS:4:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LTUS:4:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LTUS:4:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LTUS:4:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LTUS:4:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LTUS:4:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LTUS:4:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LTUS:4:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LTUS:4:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LTUS:4:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LTUS:4:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LTUS:4:EDES.PROC PP")
    field(LNK2, "LGPS:LTUS:4:EACT.PROC PP")
    field(LNK3, "LGPS:LTUS:4:EERR.DISA PP")
    field(LNK4, "LGPS:LTUS:4:ECON.PROC PP")
    field(LNK5, "LGPS:LTUS:4:BMAGX.PROC PP")
    field(LNK6, "LGPS:LTUS:4:BMAGY.PROC PP")
    field(LNK7, "LGPS:LTUS:4:BLEM.PROC PP")
    field(LNK8, "LGPS:LTUS:4:BMOD.PROC PP")
    field(LNK9, "LGPS:LTUS:4:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LTUS:4:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LTUS:4:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LTUS:4:BMAX")
  field(DOL2, "LGPS:LTUS:4:BMAX")
  field(DOL3, "LGPS:LTUS:4:BMAX")
  field(DOL4, "LGPS:LTUS:4:BMIN")
  field(DOL5, "LGPS:LTUS:4:BMIN")
  field(DOL6, "LGPS:LTUS:4:BMIN")
  field(LNK1, "LGPS:LTUS:4:BMAGX.HOPR")
  field(LNK2, "LGPS:LTUS:4:BMAGY.HOPR")
  field(LNK3, "LGPS:LTUS:4:BLEM.HOPR")
  field(LNK4, "LGPS:LTUS:4:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LTUS:4:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LTUS:4:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUS:4:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUS:4:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LTUS:4:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LTUS:4:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LTUS:4:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:4:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:4:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUS:4:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:4:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUS:4:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LTUS:4:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LTUS:4:EDES NPP MS")
  field(INPB, "LGPS:LTUS:4:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LTUS:5:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "LGPS:LTUS:5:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LTUS:5:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LTUS:5:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LTUS:5:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LTUS:5:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LTUS:5:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LTUS:5:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LTUS:5:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LTUS:5:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LTUS:5:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LTUS:5:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LTUS:5:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LTUS:5:EDES.PROC PP")
    field(LNK2, "LGPS:LTUS:5:EACT.PROC PP")
    field(LNK3, "LGPS:LTUS:5:EERR.DISA PP")
    field(LNK4, "LGPS:LTUS:5:ECON.PROC PP")
    field(LNK5, "LGPS:LTUS:5:BMAGX.PROC PP")
    field(LNK6, "LGPS:LTUS:5:BMAGY.PROC PP")
    field(LNK7, "LGPS:LTUS:5:BLEM.PROC PP")
    field(LNK8, "LGPS:LTUS:5:BMOD.PROC PP")
    field(LNK9, "LGPS:LTUS:5:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LTUS:5:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LTUS:5:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LTUS:5:BMAX")
  field(DOL2, "LGPS:LTUS:5:BMAX")
  field(DOL3, "LGPS:LTUS:5:BMAX")
  field(DOL4, "LGPS:LTUS:5:BMIN")
  field(DOL5, "LGPS:LTUS:5:BMIN")
  field(DOL6, "LGPS:LTUS:5:BMIN")
  field(LNK1, "LGPS:LTUS:5:BMAGX.HOPR")
  field(LNK2, "LGPS:LTUS:5:BMAGY.HOPR")
  field(LNK3, "LGPS:LTUS:5:BLEM.HOPR")
  field(LNK4, "LGPS:LTUS:5:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LTUS:5:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LTUS:5:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUS:5:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUS:5:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LTUS:5:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LTUS:5:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LTUS:5:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:5:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:5:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUS:5:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:5:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUS:5:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LTUS:5:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LTUS:5:EDES NPP MS")
  field(INPB, "LGPS:LTUS:5:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LTUS:6:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "LGPS:LTUS:6:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LTUS:6:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LTUS:6:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LTUS:6:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LTUS:6:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LTUS:6:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LTUS:6:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LTUS:6:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LTUS:6:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LTUS:6:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LTUS:6:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LTUS:6:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LTUS:6:EDES.PROC PP")
    field(LNK2, "LGPS:LTUS:6:EACT.PROC PP")
    field(LNK3, "LGPS:LTUS:6:EERR.DISA PP")
    field(LNK4, "LGPS:LTUS:6:ECON.PROC PP")
    field(LNK5, "LGPS:LTUS:6:BMAGX.PROC PP")
    field(LNK6, "LGPS:LTUS:6:BMAGY.PROC PP")
    field(LNK7, "LGPS:LTUS:6:BLEM.PROC PP")
    field(LNK8, "LGPS:LTUS:6:BMOD.PROC PP")
    field(LNK9, "LGPS:LTUS:6:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LTUS:6:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LTUS:6:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LTUS:6:BMAX")
  field(DOL2, "LGPS:LTUS:6:BMAX")
  field(DOL3, "LGPS:LTUS:6:BMAX")
  field(DOL4, "LGPS:LTUS:6:BMIN")
  field(DOL5, "LGPS:LTUS:6:BMIN")
  field(DOL6, "LGPS:LTUS:6:BMIN")
  field(LNK1, "LGPS:LTUS:6:BMAGX.HOPR")
  field(LNK2, "LGPS:LTUS:6:BMAGY.HOPR")
  field(LNK3, "LGPS:LTUS:6:BLEM.HOPR")
  field(LNK4, "LGPS:LTUS:6:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LTUS:6:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LTUS:6:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUS:6:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUS:6:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LTUS:6:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LTUS:6:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LTUS:6:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:6:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:6:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUS:6:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:6:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUS:6:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LTUS:6:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LTUS:6:EDES NPP MS")
  field(INPB, "LGPS:LTUS:6:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:LTUS:7:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "LGPS:LTUS:7:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:LTUS:7:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:LTUS:7:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:LTUS:7:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:LTUS:7:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:LTUS:7:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:LTUS:7:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:LTUS:7:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:LTUS:7:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:LTUS:7:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:LTUS:7:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:LTUS:7:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:LTUS:7:EDES.PROC PP")
    field(LNK2, "LGPS:LTUS:7:EACT.PROC PP")
    field(LNK3, "LGPS:LTUS:7:EERR.DISA PP")
    field(LNK4, "LGPS:LTUS:7:ECON.PROC PP")
    field(LNK5, "LGPS:LTUS:7:BMAGX.PROC PP")
    field(LNK6, "LGPS:LTUS:7:BMAGY.PROC PP")
    field(LNK7, "LGPS:LTUS:7:BLEM.PROC PP")
    field(LNK8, "LGPS:LTUS:7:BMOD.PROC PP")
    field(LNK9, "LGPS:LTUS:7:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:LTUS:7:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:LTUS:7:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:LTUS:7:BMAX")
  field(DOL2, "LGPS:LTUS:7:BMAX")
  field(DOL3, "LGPS:LTUS:7:BMAX")
  field(DOL4, "LGPS:LTUS:7:BMIN")
  field(DOL5, "LGPS:LTUS:7:BMIN")
  field(DOL6, "LGPS:LTUS:7:BMIN")
  field(LNK1, "LGPS:LTUS:7:BMAGX.HOPR")
  field(LNK2, "LGPS:LTUS:7:BMAGY.HOPR")
  field(LNK3, "LGPS:LTUS:7:BLEM.HOPR")
  field(LNK4, "LGPS:LTUS:7:BMAGX.LOPR PP")
  field(LNK5, "LGPS:LTUS:7:BMAGY.LOPR PP")
  field(LNK6, "LGPS:LTUS:7:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUS:7:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:LTUS:7:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:LTUS:7:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:LTUS:7:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:LTUS:7:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:7:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:7:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUS:7:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:LTUS:7:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:LTUS:7:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:LTUS:7:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:LTUS:7:EDES NPP MS")
  field(INPB, "LGPS:LTUS:7:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:LTUS:350:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "KICK:LTUS:350:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:LTUS:350:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:LTUS:350:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:LTUS:350:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:LTUS:350:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:LTUS:350:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:LTUS:350:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:LTUS:350:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:LTUS:350:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:LTUS:350:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:LTUS:350:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:LTUS:350:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:LTUS:350:EDES.PROC PP")
    field(LNK2, "KICK:LTUS:350:EACT.PROC PP")
    field(LNK3, "KICK:LTUS:350:EERR.DISA PP")
    field(LNK4, "KICK:LTUS:350:ECON.PROC PP")
    field(LNK5, "KICK:LTUS:350:BMAGX.PROC PP")
    field(LNK6, "KICK:LTUS:350:BMAGY.PROC PP")
    field(LNK7, "KICK:LTUS:350:BLEM.PROC PP")
    field(LNK8, "KICK:LTUS:350:BMOD.PROC PP")
    field(LNK9, "KICK:LTUS:350:EDESSAVE.PROC PP")
    field(LNKA, "KICK:LTUS:350:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:LTUS:350:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:LTUS:350:BMAX")
  field(DOL2, "KICK:LTUS:350:BMAX")
  field(DOL3, "KICK:LTUS:350:BMAX")
  field(DOL4, "KICK:LTUS:350:BMIN")
  field(DOL5, "KICK:LTUS:350:BMIN")
  field(DOL6, "KICK:LTUS:350:BMIN")
  field(LNK1, "KICK:LTUS:350:BMAGX.HOPR")
  field(LNK2, "KICK:LTUS:350:BMAGY.HOPR")
  field(LNK3, "KICK:LTUS:350:BLEM.HOPR")
  field(LNK4, "KICK:LTUS:350:BMAGX.LOPR PP")
  field(LNK5, "KICK:LTUS:350:BMAGY.LOPR PP")
  field(LNK6, "KICK:LTUS:350:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:LTUS:350:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:LTUS:350:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:LTUS:350:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:LTUS:350:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:LTUS:350:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LTUS:350:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LTUS:350:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LTUS:350:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LTUS:350:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:LTUS:350:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:LTUS:350:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:LTUS:350:EDES NPP MS")
  field(INPB, "KICK:LTUS:350:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:166:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:166:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:166:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:166:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:166:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:166:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:166:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:166:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:166:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:166:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:166:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:166:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:166:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:166:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:166:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:166:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:166:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:166:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:166:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:166:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:166:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:166:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:166:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:166:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:166:BMAX")
  field(DOL2, "BEND:LTUS:166:BMAX")
  field(DOL3, "BEND:LTUS:166:BMAX")
  field(DOL4, "BEND:LTUS:166:BMIN")
  field(DOL5, "BEND:LTUS:166:BMIN")
  field(DOL6, "BEND:LTUS:166:BMIN")
  field(LNK1, "BEND:LTUS:166:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:166:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:166:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:166:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:166:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:166:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:166:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:166:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:166:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:166:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:166:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:166:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:166:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUS:166:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:166:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUS:166:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:166:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:166:EDES NPP MS")
  field(INPB, "BEND:LTUS:166:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DMPS:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:DMPS:400:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DMPS:400:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DMPS:400:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DMPS:400:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DMPS:400:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DMPS:400:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DMPS:400:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DMPS:400:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DMPS:400:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DMPS:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DMPS:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DMPS:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DMPS:400:EDES.PROC PP")
    field(LNK2, "BEND:DMPS:400:EACT.PROC PP")
    field(LNK3, "BEND:DMPS:400:EERR.DISA PP")
    field(LNK4, "BEND:DMPS:400:ECON.PROC PP")
    field(LNK5, "BEND:DMPS:400:BMAGX.PROC PP")
    field(LNK6, "BEND:DMPS:400:BMAGY.PROC PP")
    field(LNK7, "BEND:DMPS:400:BLEM.PROC PP")
    field(LNK8, "BEND:DMPS:400:BMOD.PROC PP")
    field(LNK9, "BEND:DMPS:400:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DMPS:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DMPS:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DMPS:400:BMAX")
  field(DOL2, "BEND:DMPS:400:BMAX")
  field(DOL3, "BEND:DMPS:400:BMAX")
  field(DOL4, "BEND:DMPS:400:BMIN")
  field(DOL5, "BEND:DMPS:400:BMIN")
  field(DOL6, "BEND:DMPS:400:BMIN")
  field(LNK1, "BEND:DMPS:400:BMAGX.HOPR")
  field(LNK2, "BEND:DMPS:400:BMAGY.HOPR")
  field(LNK3, "BEND:DMPS:400:BLEM.HOPR")
  field(LNK4, "BEND:DMPS:400:BMAGX.LOPR PP")
  field(LNK5, "BEND:DMPS:400:BMAGY.LOPR PP")
  field(LNK6, "BEND:DMPS:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DMPS:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DMPS:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DMPS:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DMPS:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DMPS:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPS:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPS:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DMPS:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPS:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DMPS:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DMPS:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DMPS:400:EDES NPP MS")
  field(INPB, "BEND:DMPS:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:476:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:476:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:476:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:476:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:476:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:476:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:476:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:476:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:476:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:476:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:476:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:476:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:476:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:476:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:476:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:476:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:476:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:476:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:476:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:476:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:476:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:476:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:476:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:476:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:476:BMAX")
  field(DOL2, "BEND:LTUS:476:BMAX")
  field(DOL3, "BEND:LTUS:476:BMAX")
  field(DOL4, "BEND:LTUS:476:BMIN")
  field(DOL5, "BEND:LTUS:476:BMIN")
  field(DOL6, "BEND:LTUS:476:BMIN")
  field(LNK1, "BEND:LTUS:476:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:476:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:476:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:476:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:476:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:476:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:476:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:476:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:476:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:476:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:476:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:476:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:476:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUS:476:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:476:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUS:476:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:476:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:476:EDES NPP MS")
  field(INPB, "BEND:LTUS:476:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:525:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:525:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:525:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:525:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:525:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:525:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:525:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:525:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:525:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:525:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:525:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:525:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:525:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:525:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:525:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:525:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:525:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:525:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:525:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:525:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:525:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:525:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:525:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:525:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:525:BMAX")
  field(DOL2, "BEND:LTUS:525:BMAX")
  field(DOL3, "BEND:LTUS:525:BMAX")
  field(DOL4, "BEND:LTUS:525:BMIN")
  field(DOL5, "BEND:LTUS:525:BMIN")
  field(DOL6, "BEND:LTUS:525:BMIN")
  field(LNK1, "BEND:LTUS:525:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:525:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:525:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:525:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:525:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:525:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:525:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:525:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:525:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:525:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:525:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:525:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:525:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUS:525:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:525:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUS:525:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:525:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:525:EDES NPP MS")
  field(INPB, "BEND:LTUS:525:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:764:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:764:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:764:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:764:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:764:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:764:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:764:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:764:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:764:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:764:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:764:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:764:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:764:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:764:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:764:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:764:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:764:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:764:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:764:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:764:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:764:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:764:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:764:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:764:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:764:BMAX")
  field(DOL2, "BEND:LTUS:764:BMAX")
  field(DOL3, "BEND:LTUS:764:BMAX")
  field(DOL4, "BEND:LTUS:764:BMIN")
  field(DOL5, "BEND:LTUS:764:BMIN")
  field(DOL6, "BEND:LTUS:764:BMIN")
  field(LNK1, "BEND:LTUS:764:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:764:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:764:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:764:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:764:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:764:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:764:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:764:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:764:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:764:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:764:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:764:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:764:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUS:764:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:764:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:LTUS:764:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:764:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:764:EDES NPP MS")
  field(INPB, "BEND:LTUS:764:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUS:165:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUS:165:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUS:165:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUS:165:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUS:165:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUS:165:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUS:165:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUS:165:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUS:165:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUS:165:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUS:165:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUS:165:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUS:165:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUS:165:EDES.PROC PP")
    field(LNK2, "BTRM:LTUS:165:EACT.PROC PP")
    field(LNK3, "BTRM:LTUS:165:EERR.DISA PP")
    field(LNK4, "BTRM:LTUS:165:ECON.PROC PP")
    field(LNK5, "BTRM:LTUS:165:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUS:165:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUS:165:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUS:165:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUS:165:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUS:165:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUS:165:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUS:165:BMAX")
  field(DOL2, "BTRM:LTUS:165:BMAX")
  field(DOL3, "BTRM:LTUS:165:BMAX")
  field(DOL4, "BTRM:LTUS:165:BMIN")
  field(DOL5, "BTRM:LTUS:165:BMIN")
  field(DOL6, "BTRM:LTUS:165:BMIN")
  field(LNK1, "BTRM:LTUS:165:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUS:165:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUS:165:BLEM.HOPR")
  field(LNK4, "BTRM:LTUS:165:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUS:165:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUS:165:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:165:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:165:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUS:165:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUS:165:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUS:165:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:165:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:165:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:165:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:165:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:165:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUS:165:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUS:165:EDES NPP MS")
  field(INPB, "BTRM:LTUS:165:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUS:167:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUS:167:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUS:167:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUS:167:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUS:167:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUS:167:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUS:167:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUS:167:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUS:167:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUS:167:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUS:167:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUS:167:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUS:167:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUS:167:EDES.PROC PP")
    field(LNK2, "BTRM:LTUS:167:EACT.PROC PP")
    field(LNK3, "BTRM:LTUS:167:EERR.DISA PP")
    field(LNK4, "BTRM:LTUS:167:ECON.PROC PP")
    field(LNK5, "BTRM:LTUS:167:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUS:167:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUS:167:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUS:167:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUS:167:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUS:167:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUS:167:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUS:167:BMAX")
  field(DOL2, "BTRM:LTUS:167:BMAX")
  field(DOL3, "BTRM:LTUS:167:BMAX")
  field(DOL4, "BTRM:LTUS:167:BMIN")
  field(DOL5, "BTRM:LTUS:167:BMIN")
  field(DOL6, "BTRM:LTUS:167:BMIN")
  field(LNK1, "BTRM:LTUS:167:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUS:167:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUS:167:BLEM.HOPR")
  field(LNK4, "BTRM:LTUS:167:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUS:167:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUS:167:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:167:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:167:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUS:167:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUS:167:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUS:167:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:167:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:167:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:167:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:167:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:167:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUS:167:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUS:167:EDES NPP MS")
  field(INPB, "BTRM:LTUS:167:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUS:168:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUS:168:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUS:168:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUS:168:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUS:168:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUS:168:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUS:168:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUS:168:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUS:168:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUS:168:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUS:168:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUS:168:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUS:168:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUS:168:EDES.PROC PP")
    field(LNK2, "BTRM:LTUS:168:EACT.PROC PP")
    field(LNK3, "BTRM:LTUS:168:EERR.DISA PP")
    field(LNK4, "BTRM:LTUS:168:ECON.PROC PP")
    field(LNK5, "BTRM:LTUS:168:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUS:168:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUS:168:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUS:168:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUS:168:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUS:168:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUS:168:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUS:168:BMAX")
  field(DOL2, "BTRM:LTUS:168:BMAX")
  field(DOL3, "BTRM:LTUS:168:BMAX")
  field(DOL4, "BTRM:LTUS:168:BMIN")
  field(DOL5, "BTRM:LTUS:168:BMIN")
  field(DOL6, "BTRM:LTUS:168:BMIN")
  field(LNK1, "BTRM:LTUS:168:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUS:168:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUS:168:BLEM.HOPR")
  field(LNK4, "BTRM:LTUS:168:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUS:168:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUS:168:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:168:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:168:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUS:168:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUS:168:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUS:168:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:168:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:168:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:168:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:168:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:168:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUS:168:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUS:168:EDES NPP MS")
  field(INPB, "BTRM:LTUS:168:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUS:175:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUS:175:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUS:175:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUS:175:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUS:175:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUS:175:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUS:175:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUS:175:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUS:175:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUS:175:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUS:175:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUS:175:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUS:175:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUS:175:EDES.PROC PP")
    field(LNK2, "BTRM:LTUS:175:EACT.PROC PP")
    field(LNK3, "BTRM:LTUS:175:EERR.DISA PP")
    field(LNK4, "BTRM:LTUS:175:ECON.PROC PP")
    field(LNK5, "BTRM:LTUS:175:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUS:175:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUS:175:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUS:175:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUS:175:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUS:175:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUS:175:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUS:175:BMAX")
  field(DOL2, "BTRM:LTUS:175:BMAX")
  field(DOL3, "BTRM:LTUS:175:BMAX")
  field(DOL4, "BTRM:LTUS:175:BMIN")
  field(DOL5, "BTRM:LTUS:175:BMIN")
  field(DOL6, "BTRM:LTUS:175:BMIN")
  field(LNK1, "BTRM:LTUS:175:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUS:175:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUS:175:BLEM.HOPR")
  field(LNK4, "BTRM:LTUS:175:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUS:175:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUS:175:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:175:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:175:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUS:175:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUS:175:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUS:175:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:175:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:175:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:175:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:175:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:175:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUS:175:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUS:175:EDES NPP MS")
  field(INPB, "BTRM:LTUS:175:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUS:460:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUS:460:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUS:460:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUS:460:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUS:460:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUS:460:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUS:460:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUS:460:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUS:460:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUS:460:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUS:460:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUS:460:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUS:460:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUS:460:EDES.PROC PP")
    field(LNK2, "BTRM:LTUS:460:EACT.PROC PP")
    field(LNK3, "BTRM:LTUS:460:EERR.DISA PP")
    field(LNK4, "BTRM:LTUS:460:ECON.PROC PP")
    field(LNK5, "BTRM:LTUS:460:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUS:460:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUS:460:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUS:460:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUS:460:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUS:460:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUS:460:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUS:460:BMAX")
  field(DOL2, "BTRM:LTUS:460:BMAX")
  field(DOL3, "BTRM:LTUS:460:BMAX")
  field(DOL4, "BTRM:LTUS:460:BMIN")
  field(DOL5, "BTRM:LTUS:460:BMIN")
  field(DOL6, "BTRM:LTUS:460:BMIN")
  field(LNK1, "BTRM:LTUS:460:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUS:460:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUS:460:BLEM.HOPR")
  field(LNK4, "BTRM:LTUS:460:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUS:460:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUS:460:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:460:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:460:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUS:460:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUS:460:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUS:460:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:460:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:460:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:460:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:460:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:460:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUS:460:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUS:460:EDES NPP MS")
  field(INPB, "BTRM:LTUS:460:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUS:475:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUS:475:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUS:475:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUS:475:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUS:475:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUS:475:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUS:475:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUS:475:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUS:475:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUS:475:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUS:475:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUS:475:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUS:475:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUS:475:EDES.PROC PP")
    field(LNK2, "BTRM:LTUS:475:EACT.PROC PP")
    field(LNK3, "BTRM:LTUS:475:EERR.DISA PP")
    field(LNK4, "BTRM:LTUS:475:ECON.PROC PP")
    field(LNK5, "BTRM:LTUS:475:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUS:475:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUS:475:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUS:475:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUS:475:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUS:475:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUS:475:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUS:475:BMAX")
  field(DOL2, "BTRM:LTUS:475:BMAX")
  field(DOL3, "BTRM:LTUS:475:BMAX")
  field(DOL4, "BTRM:LTUS:475:BMIN")
  field(DOL5, "BTRM:LTUS:475:BMIN")
  field(DOL6, "BTRM:LTUS:475:BMIN")
  field(LNK1, "BTRM:LTUS:475:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUS:475:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUS:475:BLEM.HOPR")
  field(LNK4, "BTRM:LTUS:475:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUS:475:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUS:475:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:475:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:475:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUS:475:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUS:475:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUS:475:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:475:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:475:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:475:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:475:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:475:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUS:475:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUS:475:EDES NPP MS")
  field(INPB, "BTRM:LTUS:475:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUS:477:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUS:477:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUS:477:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUS:477:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUS:477:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUS:477:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUS:477:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUS:477:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUS:477:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUS:477:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUS:477:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUS:477:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUS:477:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUS:477:EDES.PROC PP")
    field(LNK2, "BTRM:LTUS:477:EACT.PROC PP")
    field(LNK3, "BTRM:LTUS:477:EERR.DISA PP")
    field(LNK4, "BTRM:LTUS:477:ECON.PROC PP")
    field(LNK5, "BTRM:LTUS:477:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUS:477:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUS:477:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUS:477:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUS:477:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUS:477:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUS:477:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUS:477:BMAX")
  field(DOL2, "BTRM:LTUS:477:BMAX")
  field(DOL3, "BTRM:LTUS:477:BMAX")
  field(DOL4, "BTRM:LTUS:477:BMIN")
  field(DOL5, "BTRM:LTUS:477:BMIN")
  field(DOL6, "BTRM:LTUS:477:BMIN")
  field(LNK1, "BTRM:LTUS:477:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUS:477:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUS:477:BLEM.HOPR")
  field(LNK4, "BTRM:LTUS:477:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUS:477:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUS:477:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:477:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:477:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUS:477:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUS:477:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUS:477:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:477:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:477:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:477:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:477:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:477:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUS:477:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUS:477:EDES NPP MS")
  field(INPB, "BTRM:LTUS:477:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUS:478:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUS:478:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUS:478:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUS:478:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUS:478:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUS:478:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUS:478:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUS:478:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUS:478:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUS:478:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUS:478:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUS:478:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUS:478:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUS:478:EDES.PROC PP")
    field(LNK2, "BTRM:LTUS:478:EACT.PROC PP")
    field(LNK3, "BTRM:LTUS:478:EERR.DISA PP")
    field(LNK4, "BTRM:LTUS:478:ECON.PROC PP")
    field(LNK5, "BTRM:LTUS:478:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUS:478:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUS:478:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUS:478:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUS:478:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUS:478:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUS:478:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUS:478:BMAX")
  field(DOL2, "BTRM:LTUS:478:BMAX")
  field(DOL3, "BTRM:LTUS:478:BMAX")
  field(DOL4, "BTRM:LTUS:478:BMIN")
  field(DOL5, "BTRM:LTUS:478:BMIN")
  field(DOL6, "BTRM:LTUS:478:BMIN")
  field(LNK1, "BTRM:LTUS:478:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUS:478:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUS:478:BLEM.HOPR")
  field(LNK4, "BTRM:LTUS:478:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUS:478:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUS:478:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:478:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:478:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUS:478:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUS:478:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUS:478:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:478:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:478:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:478:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:478:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:478:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUS:478:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUS:478:EDES NPP MS")
  field(INPB, "BTRM:LTUS:478:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUS:763:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUS:763:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUS:763:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUS:763:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUS:763:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUS:763:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUS:763:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUS:763:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUS:763:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUS:763:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUS:763:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUS:763:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUS:763:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUS:763:EDES.PROC PP")
    field(LNK2, "BTRM:LTUS:763:EACT.PROC PP")
    field(LNK3, "BTRM:LTUS:763:EERR.DISA PP")
    field(LNK4, "BTRM:LTUS:763:ECON.PROC PP")
    field(LNK5, "BTRM:LTUS:763:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUS:763:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUS:763:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUS:763:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUS:763:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUS:763:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUS:763:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUS:763:BMAX")
  field(DOL2, "BTRM:LTUS:763:BMAX")
  field(DOL3, "BTRM:LTUS:763:BMAX")
  field(DOL4, "BTRM:LTUS:763:BMIN")
  field(DOL5, "BTRM:LTUS:763:BMIN")
  field(DOL6, "BTRM:LTUS:763:BMIN")
  field(LNK1, "BTRM:LTUS:763:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUS:763:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUS:763:BLEM.HOPR")
  field(LNK4, "BTRM:LTUS:763:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUS:763:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUS:763:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:763:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:763:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUS:763:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUS:763:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUS:763:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:763:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:763:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:763:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:763:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:763:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUS:763:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUS:763:EDES NPP MS")
  field(INPB, "BTRM:LTUS:763:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUS:765:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUS:765:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUS:765:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUS:765:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUS:765:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUS:765:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUS:765:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUS:765:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUS:765:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUS:765:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUS:765:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUS:765:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUS:765:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUS:765:EDES.PROC PP")
    field(LNK2, "BTRM:LTUS:765:EACT.PROC PP")
    field(LNK3, "BTRM:LTUS:765:EERR.DISA PP")
    field(LNK4, "BTRM:LTUS:765:ECON.PROC PP")
    field(LNK5, "BTRM:LTUS:765:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUS:765:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUS:765:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUS:765:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUS:765:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUS:765:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUS:765:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUS:765:BMAX")
  field(DOL2, "BTRM:LTUS:765:BMAX")
  field(DOL3, "BTRM:LTUS:765:BMAX")
  field(DOL4, "BTRM:LTUS:765:BMIN")
  field(DOL5, "BTRM:LTUS:765:BMIN")
  field(DOL6, "BTRM:LTUS:765:BMIN")
  field(LNK1, "BTRM:LTUS:765:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUS:765:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUS:765:BLEM.HOPR")
  field(LNK4, "BTRM:LTUS:765:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUS:765:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUS:765:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:765:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:765:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUS:765:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUS:765:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUS:765:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:765:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:765:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:765:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:765:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:765:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUS:765:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUS:765:EDES NPP MS")
  field(INPB, "BTRM:LTUS:765:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:LTUS:766:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BTRM:LTUS:766:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:LTUS:766:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:LTUS:766:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:LTUS:766:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:LTUS:766:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:LTUS:766:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:LTUS:766:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:LTUS:766:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:LTUS:766:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:LTUS:766:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:LTUS:766:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:LTUS:766:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:LTUS:766:EDES.PROC PP")
    field(LNK2, "BTRM:LTUS:766:EACT.PROC PP")
    field(LNK3, "BTRM:LTUS:766:EERR.DISA PP")
    field(LNK4, "BTRM:LTUS:766:ECON.PROC PP")
    field(LNK5, "BTRM:LTUS:766:BMAGX.PROC PP")
    field(LNK6, "BTRM:LTUS:766:BMAGY.PROC PP")
    field(LNK7, "BTRM:LTUS:766:BLEM.PROC PP")
    field(LNK8, "BTRM:LTUS:766:BMOD.PROC PP")
    field(LNK9, "BTRM:LTUS:766:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:LTUS:766:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:LTUS:766:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:LTUS:766:BMAX")
  field(DOL2, "BTRM:LTUS:766:BMAX")
  field(DOL3, "BTRM:LTUS:766:BMAX")
  field(DOL4, "BTRM:LTUS:766:BMIN")
  field(DOL5, "BTRM:LTUS:766:BMIN")
  field(DOL6, "BTRM:LTUS:766:BMIN")
  field(LNK1, "BTRM:LTUS:766:BMAGX.HOPR")
  field(LNK2, "BTRM:LTUS:766:BMAGY.HOPR")
  field(LNK3, "BTRM:LTUS:766:BLEM.HOPR")
  field(LNK4, "BTRM:LTUS:766:BMAGX.LOPR PP")
  field(LNK5, "BTRM:LTUS:766:BMAGY.LOPR PP")
  field(LNK6, "BTRM:LTUS:766:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:766:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:LTUS:766:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:LTUS:766:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:LTUS:766:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:LTUS:766:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:766:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:766:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:766:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:LTUS:766:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:LTUS:766:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:LTUS:766:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:LTUS:766:EDES NPP MS")
  field(INPB, "BTRM:LTUS:766:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:110:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:110:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:110:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:110:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:110:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:110:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:110:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:110:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:110:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:110:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:110:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:110:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:110:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:110:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:110:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:110:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:110:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:110:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:110:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:110:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:110:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:110:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:110:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:110:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:110:BMAX")
  field(DOL2, "QUAD:LTUS:110:BMAX")
  field(DOL3, "QUAD:LTUS:110:BMAX")
  field(DOL4, "QUAD:LTUS:110:BMIN")
  field(DOL5, "QUAD:LTUS:110:BMIN")
  field(DOL6, "QUAD:LTUS:110:BMIN")
  field(LNK1, "QUAD:LTUS:110:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:110:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:110:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:110:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:110:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:110:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:110:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:110:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:110:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:110:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:110:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:110:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:110:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:110:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:110:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:110:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:110:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:110:EDES NPP MS")
  field(INPB, "QUAD:LTUS:110:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:120:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:120:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:120:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:120:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:120:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:120:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:120:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:120:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:120:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:120:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:120:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:120:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:120:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:120:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:120:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:120:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:120:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:120:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:120:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:120:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:120:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:120:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:120:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:120:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:120:BMAX")
  field(DOL2, "QUAD:LTUS:120:BMAX")
  field(DOL3, "QUAD:LTUS:120:BMAX")
  field(DOL4, "QUAD:LTUS:120:BMIN")
  field(DOL5, "QUAD:LTUS:120:BMIN")
  field(DOL6, "QUAD:LTUS:120:BMIN")
  field(LNK1, "QUAD:LTUS:120:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:120:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:120:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:120:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:120:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:120:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:120:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:120:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:120:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:120:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:120:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:120:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:120:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:120:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:120:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:120:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:120:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:120:EDES NPP MS")
  field(INPB, "QUAD:LTUS:120:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:150:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:150:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:150:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:150:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:150:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:150:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:150:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:150:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:150:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:150:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:150:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:150:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:150:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:150:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:150:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:150:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:150:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:150:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:150:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:150:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:150:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:150:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:150:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:150:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:150:BMAX")
  field(DOL2, "QUAD:LTUS:150:BMAX")
  field(DOL3, "QUAD:LTUS:150:BMAX")
  field(DOL4, "QUAD:LTUS:150:BMIN")
  field(DOL5, "QUAD:LTUS:150:BMIN")
  field(DOL6, "QUAD:LTUS:150:BMIN")
  field(LNK1, "QUAD:LTUS:150:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:150:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:150:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:150:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:150:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:150:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:150:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:150:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:150:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:150:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:150:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:150:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:150:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:150:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:150:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:150:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:150:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:150:EDES NPP MS")
  field(INPB, "QUAD:LTUS:150:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:180:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:180:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:180:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:180:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:180:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:180:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:180:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:180:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:180:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:180:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:180:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:180:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:180:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:180:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:180:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:180:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:180:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:180:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:180:BMAX")
  field(DOL2, "QUAD:LTUS:180:BMAX")
  field(DOL3, "QUAD:LTUS:180:BMAX")
  field(DOL4, "QUAD:LTUS:180:BMIN")
  field(DOL5, "QUAD:LTUS:180:BMIN")
  field(DOL6, "QUAD:LTUS:180:BMIN")
  field(LNK1, "QUAD:LTUS:180:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:180:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:180:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:180:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:180:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:180:EDES NPP MS")
  field(INPB, "QUAD:LTUS:180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:235:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:235:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:235:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:235:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:235:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:235:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:235:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:235:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:235:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:235:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:235:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:235:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:235:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:235:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:235:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:235:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:235:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:235:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:235:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:235:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:235:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:235:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:235:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:235:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:235:BMAX")
  field(DOL2, "QUAD:LTUS:235:BMAX")
  field(DOL3, "QUAD:LTUS:235:BMAX")
  field(DOL4, "QUAD:LTUS:235:BMIN")
  field(DOL5, "QUAD:LTUS:235:BMIN")
  field(DOL6, "QUAD:LTUS:235:BMIN")
  field(LNK1, "QUAD:LTUS:235:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:235:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:235:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:235:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:235:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:235:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:235:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:235:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:235:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:235:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:235:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:235:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:235:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:235:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:235:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:235:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:235:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:235:EDES NPP MS")
  field(INPB, "QUAD:LTUS:235:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:470:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:470:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:470:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:470:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:470:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:470:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:470:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:470:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:470:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:470:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:470:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:470:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:470:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:470:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:470:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:470:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:470:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:470:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:470:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:470:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:470:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:470:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:470:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:470:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:470:BMAX")
  field(DOL2, "QUAD:LTUS:470:BMAX")
  field(DOL3, "QUAD:LTUS:470:BMAX")
  field(DOL4, "QUAD:LTUS:470:BMIN")
  field(DOL5, "QUAD:LTUS:470:BMIN")
  field(DOL6, "QUAD:LTUS:470:BMIN")
  field(LNK1, "QUAD:LTUS:470:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:470:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:470:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:470:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:470:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:470:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:470:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:470:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:470:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:470:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:470:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:470:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:470:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:470:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:470:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:470:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:470:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:470:EDES NPP MS")
  field(INPB, "QUAD:LTUS:470:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:500:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:500:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:500:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:500:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:500:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:500:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:500:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:500:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:500:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:500:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:500:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:500:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:500:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:500:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:500:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:500:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:500:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:500:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:500:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:500:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:500:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:500:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:500:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:500:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:500:BMAX")
  field(DOL2, "QUAD:LTUS:500:BMAX")
  field(DOL3, "QUAD:LTUS:500:BMAX")
  field(DOL4, "QUAD:LTUS:500:BMIN")
  field(DOL5, "QUAD:LTUS:500:BMIN")
  field(DOL6, "QUAD:LTUS:500:BMIN")
  field(LNK1, "QUAD:LTUS:500:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:500:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:500:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:500:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:500:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:500:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:500:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:500:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:500:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:500:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:500:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:500:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:500:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:500:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:500:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:500:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:500:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:500:EDES NPP MS")
  field(INPB, "QUAD:LTUS:500:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:510:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:510:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:510:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:510:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:510:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:510:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:510:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:510:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:510:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:510:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:510:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:510:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:510:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:510:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:510:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:510:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:510:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:510:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:510:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:510:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:510:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:510:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:510:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:510:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:510:BMAX")
  field(DOL2, "QUAD:LTUS:510:BMAX")
  field(DOL3, "QUAD:LTUS:510:BMAX")
  field(DOL4, "QUAD:LTUS:510:BMIN")
  field(DOL5, "QUAD:LTUS:510:BMIN")
  field(DOL6, "QUAD:LTUS:510:BMIN")
  field(LNK1, "QUAD:LTUS:510:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:510:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:510:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:510:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:510:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:510:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:510:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:510:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:510:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:510:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:510:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:510:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:510:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:510:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:510:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:510:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:510:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:510:EDES NPP MS")
  field(INPB, "QUAD:LTUS:510:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:540:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:540:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:540:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:540:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:540:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:540:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:540:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:540:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:540:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:540:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:540:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:540:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:540:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:540:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:540:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:540:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:540:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:540:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:540:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:540:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:540:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:540:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:540:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:540:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:540:BMAX")
  field(DOL2, "QUAD:LTUS:540:BMAX")
  field(DOL3, "QUAD:LTUS:540:BMAX")
  field(DOL4, "QUAD:LTUS:540:BMIN")
  field(DOL5, "QUAD:LTUS:540:BMIN")
  field(DOL6, "QUAD:LTUS:540:BMIN")
  field(LNK1, "QUAD:LTUS:540:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:540:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:540:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:540:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:540:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:540:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:540:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:540:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:540:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:540:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:540:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:540:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:540:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:540:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:540:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:540:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:540:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:540:EDES NPP MS")
  field(INPB, "QUAD:LTUS:540:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:570:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:570:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:570:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:570:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:570:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:570:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:570:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:570:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:570:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:570:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:570:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:570:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:570:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:570:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:570:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:570:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:570:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:570:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:570:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:570:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:570:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:570:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:570:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:570:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:570:BMAX")
  field(DOL2, "QUAD:LTUS:570:BMAX")
  field(DOL3, "QUAD:LTUS:570:BMAX")
  field(DOL4, "QUAD:LTUS:570:BMIN")
  field(DOL5, "QUAD:LTUS:570:BMIN")
  field(DOL6, "QUAD:LTUS:570:BMIN")
  field(LNK1, "QUAD:LTUS:570:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:570:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:570:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:570:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:570:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:570:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:570:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:570:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:570:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:570:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:570:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:570:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:570:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:570:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:570:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:570:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:570:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:570:EDES NPP MS")
  field(INPB, "QUAD:LTUS:570:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:580:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:580:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:580:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:580:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:580:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:580:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:580:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:580:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:580:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:580:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:580:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:580:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:580:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:580:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:580:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:580:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:580:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:580:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:580:BMAX")
  field(DOL2, "QUAD:LTUS:580:BMAX")
  field(DOL3, "QUAD:LTUS:580:BMAX")
  field(DOL4, "QUAD:LTUS:580:BMIN")
  field(DOL5, "QUAD:LTUS:580:BMIN")
  field(DOL6, "QUAD:LTUS:580:BMIN")
  field(LNK1, "QUAD:LTUS:580:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:580:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:580:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:580:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:580:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:580:EDES NPP MS")
  field(INPB, "QUAD:LTUS:580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:620:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:620:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:620:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:620:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:620:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:620:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:620:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:620:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:620:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:620:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:620:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:620:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:620:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:620:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:620:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:620:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:620:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:620:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:620:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:620:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:620:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:620:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:620:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:620:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:620:BMAX")
  field(DOL2, "QUAD:LTUS:620:BMAX")
  field(DOL3, "QUAD:LTUS:620:BMAX")
  field(DOL4, "QUAD:LTUS:620:BMIN")
  field(DOL5, "QUAD:LTUS:620:BMIN")
  field(DOL6, "QUAD:LTUS:620:BMIN")
  field(LNK1, "QUAD:LTUS:620:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:620:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:620:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:620:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:620:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:620:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:620:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:620:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:620:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:620:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:620:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:620:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:620:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:620:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:620:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:620:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:620:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:620:EDES NPP MS")
  field(INPB, "QUAD:LTUS:620:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:640:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:640:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:640:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:640:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:640:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:640:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:640:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:640:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:640:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:640:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:640:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:640:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:640:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:640:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:640:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:640:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:640:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:640:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:640:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:640:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:640:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:640:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:640:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:640:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:640:BMAX")
  field(DOL2, "QUAD:LTUS:640:BMAX")
  field(DOL3, "QUAD:LTUS:640:BMAX")
  field(DOL4, "QUAD:LTUS:640:BMIN")
  field(DOL5, "QUAD:LTUS:640:BMIN")
  field(DOL6, "QUAD:LTUS:640:BMIN")
  field(LNK1, "QUAD:LTUS:640:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:640:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:640:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:640:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:640:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:640:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:640:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:640:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:640:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:640:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:640:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:640:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:640:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:640:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:640:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:640:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:640:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:640:EDES NPP MS")
  field(INPB, "QUAD:LTUS:640:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:660:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:660:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:660:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:660:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:660:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:660:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:660:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:660:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:660:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:660:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:660:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:660:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:660:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:660:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:660:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:660:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:660:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:660:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:660:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:660:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:660:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:660:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:660:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:660:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:660:BMAX")
  field(DOL2, "QUAD:LTUS:660:BMAX")
  field(DOL3, "QUAD:LTUS:660:BMAX")
  field(DOL4, "QUAD:LTUS:660:BMIN")
  field(DOL5, "QUAD:LTUS:660:BMIN")
  field(DOL6, "QUAD:LTUS:660:BMIN")
  field(LNK1, "QUAD:LTUS:660:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:660:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:660:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:660:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:660:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:660:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:660:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:660:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:660:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:660:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:660:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:660:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:660:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:660:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:660:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:660:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:660:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:660:EDES NPP MS")
  field(INPB, "QUAD:LTUS:660:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:665:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:665:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:665:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:665:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:665:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:665:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:665:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:665:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:665:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:665:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:665:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:665:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:665:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:665:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:665:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:665:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:665:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:665:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:665:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:665:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:665:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:665:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:665:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:665:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:665:BMAX")
  field(DOL2, "QUAD:LTUS:665:BMAX")
  field(DOL3, "QUAD:LTUS:665:BMAX")
  field(DOL4, "QUAD:LTUS:665:BMIN")
  field(DOL5, "QUAD:LTUS:665:BMIN")
  field(DOL6, "QUAD:LTUS:665:BMIN")
  field(LNK1, "QUAD:LTUS:665:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:665:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:665:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:665:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:665:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:665:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:665:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:665:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:665:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:665:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:665:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:665:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:665:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:665:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:665:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:665:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:665:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:665:EDES NPP MS")
  field(INPB, "QUAD:LTUS:665:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:680:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:680:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:680:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:680:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:680:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:680:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:680:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:680:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:680:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:680:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:680:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:680:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:680:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:680:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:680:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:680:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:680:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:680:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:680:BMAX")
  field(DOL2, "QUAD:LTUS:680:BMAX")
  field(DOL3, "QUAD:LTUS:680:BMAX")
  field(DOL4, "QUAD:LTUS:680:BMIN")
  field(DOL5, "QUAD:LTUS:680:BMIN")
  field(DOL6, "QUAD:LTUS:680:BMIN")
  field(LNK1, "QUAD:LTUS:680:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:680:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:680:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:680:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:680:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:680:EDES NPP MS")
  field(INPB, "QUAD:LTUS:680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:720:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:720:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:720:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:720:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:720:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:720:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:720:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:720:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:720:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:720:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:720:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:720:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:720:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:720:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:720:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:720:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:720:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:720:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:720:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:720:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:720:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:720:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:720:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:720:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:720:BMAX")
  field(DOL2, "QUAD:LTUS:720:BMAX")
  field(DOL3, "QUAD:LTUS:720:BMAX")
  field(DOL4, "QUAD:LTUS:720:BMIN")
  field(DOL5, "QUAD:LTUS:720:BMIN")
  field(DOL6, "QUAD:LTUS:720:BMIN")
  field(LNK1, "QUAD:LTUS:720:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:720:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:720:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:720:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:720:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:720:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:720:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:720:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:720:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:720:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:720:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:720:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:720:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:720:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:720:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:720:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:720:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:720:EDES NPP MS")
  field(INPB, "QUAD:LTUS:720:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:725:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:725:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:725:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:725:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:725:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:725:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:725:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:725:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:725:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:725:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:725:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:725:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:725:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:725:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:725:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:725:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:725:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:725:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:725:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:725:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:725:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:725:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:725:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:725:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:725:BMAX")
  field(DOL2, "QUAD:LTUS:725:BMAX")
  field(DOL3, "QUAD:LTUS:725:BMAX")
  field(DOL4, "QUAD:LTUS:725:BMIN")
  field(DOL5, "QUAD:LTUS:725:BMIN")
  field(DOL6, "QUAD:LTUS:725:BMIN")
  field(LNK1, "QUAD:LTUS:725:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:725:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:725:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:725:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:725:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:725:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:725:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:725:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:725:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:725:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:725:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:725:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:725:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:725:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:725:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:725:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:725:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:725:EDES NPP MS")
  field(INPB, "QUAD:LTUS:725:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:730:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:730:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:730:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:730:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:730:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:730:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:730:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:730:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:730:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:730:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:730:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:730:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:730:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:730:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:730:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:730:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:730:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:730:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:730:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:730:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:730:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:730:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:730:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:730:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:730:BMAX")
  field(DOL2, "QUAD:LTUS:730:BMAX")
  field(DOL3, "QUAD:LTUS:730:BMAX")
  field(DOL4, "QUAD:LTUS:730:BMIN")
  field(DOL5, "QUAD:LTUS:730:BMIN")
  field(DOL6, "QUAD:LTUS:730:BMIN")
  field(LNK1, "QUAD:LTUS:730:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:730:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:730:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:730:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:730:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:730:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:730:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:730:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:730:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:730:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:730:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:730:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:730:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:730:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:730:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:730:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:730:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:730:EDES NPP MS")
  field(INPB, "QUAD:LTUS:730:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:740:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:740:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:740:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:740:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:740:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:740:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:740:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:740:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:740:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:740:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:740:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:740:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:740:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:740:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:740:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:740:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:740:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:740:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:740:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:740:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:740:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:740:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:740:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:740:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:740:BMAX")
  field(DOL2, "QUAD:LTUS:740:BMAX")
  field(DOL3, "QUAD:LTUS:740:BMAX")
  field(DOL4, "QUAD:LTUS:740:BMIN")
  field(DOL5, "QUAD:LTUS:740:BMIN")
  field(DOL6, "QUAD:LTUS:740:BMIN")
  field(LNK1, "QUAD:LTUS:740:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:740:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:740:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:740:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:740:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:740:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:740:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:740:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:740:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:740:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:740:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:740:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:740:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:740:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:740:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:740:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:740:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:740:EDES NPP MS")
  field(INPB, "QUAD:LTUS:740:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:750:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:750:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:750:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:750:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:750:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:750:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:750:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:750:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:750:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:750:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:750:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:750:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:750:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:750:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:750:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:750:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:750:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:750:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:750:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:750:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:750:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:750:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:750:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:750:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:750:BMAX")
  field(DOL2, "QUAD:LTUS:750:BMAX")
  field(DOL3, "QUAD:LTUS:750:BMAX")
  field(DOL4, "QUAD:LTUS:750:BMIN")
  field(DOL5, "QUAD:LTUS:750:BMIN")
  field(DOL6, "QUAD:LTUS:750:BMIN")
  field(LNK1, "QUAD:LTUS:750:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:750:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:750:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:750:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:750:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:750:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:750:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:750:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:750:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:750:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:750:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:750:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:750:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:750:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:750:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:750:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:750:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:750:EDES NPP MS")
  field(INPB, "QUAD:LTUS:750:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:760:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:760:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:760:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:760:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:760:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:760:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:760:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:760:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:760:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:760:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:760:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:760:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:760:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:760:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:760:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:760:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:760:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:760:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:760:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:760:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:760:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:760:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:760:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:760:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:760:BMAX")
  field(DOL2, "QUAD:LTUS:760:BMAX")
  field(DOL3, "QUAD:LTUS:760:BMAX")
  field(DOL4, "QUAD:LTUS:760:BMIN")
  field(DOL5, "QUAD:LTUS:760:BMIN")
  field(DOL6, "QUAD:LTUS:760:BMIN")
  field(LNK1, "QUAD:LTUS:760:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:760:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:760:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:760:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:760:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:760:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:760:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:760:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:760:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:760:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:760:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:760:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:760:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:760:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:760:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:760:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:760:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:760:EDES NPP MS")
  field(INPB, "QUAD:LTUS:760:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:772:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:772:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:772:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:772:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:772:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:772:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:772:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:772:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:772:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:772:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:772:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:772:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:772:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:772:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:772:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:772:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:772:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:772:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:772:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:772:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:772:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:772:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:772:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:772:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:772:BMAX")
  field(DOL2, "QUAD:LTUS:772:BMAX")
  field(DOL3, "QUAD:LTUS:772:BMAX")
  field(DOL4, "QUAD:LTUS:772:BMIN")
  field(DOL5, "QUAD:LTUS:772:BMIN")
  field(DOL6, "QUAD:LTUS:772:BMIN")
  field(LNK1, "QUAD:LTUS:772:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:772:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:772:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:772:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:772:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:772:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:772:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:772:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:772:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:772:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:772:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:772:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:772:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:772:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:772:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:772:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:772:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:772:EDES NPP MS")
  field(INPB, "QUAD:LTUS:772:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:780:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:780:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:780:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:780:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:780:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:780:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:780:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:780:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:780:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:780:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:780:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:780:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:780:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:780:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:780:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:780:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:780:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:780:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:780:BMAX")
  field(DOL2, "QUAD:LTUS:780:BMAX")
  field(DOL3, "QUAD:LTUS:780:BMAX")
  field(DOL4, "QUAD:LTUS:780:BMIN")
  field(DOL5, "QUAD:LTUS:780:BMIN")
  field(DOL6, "QUAD:LTUS:780:BMIN")
  field(LNK1, "QUAD:LTUS:780:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:780:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:780:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:780:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:780:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:780:EDES NPP MS")
  field(INPB, "QUAD:LTUS:780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:820:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:820:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:820:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:820:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:820:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:820:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:820:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:820:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:820:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:820:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:820:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:820:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:820:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:820:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:820:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:820:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:820:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:820:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:820:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:820:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:820:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:820:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:820:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:820:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:820:BMAX")
  field(DOL2, "QUAD:LTUS:820:BMAX")
  field(DOL3, "QUAD:LTUS:820:BMAX")
  field(DOL4, "QUAD:LTUS:820:BMIN")
  field(DOL5, "QUAD:LTUS:820:BMIN")
  field(DOL6, "QUAD:LTUS:820:BMIN")
  field(LNK1, "QUAD:LTUS:820:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:820:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:820:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:820:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:820:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:820:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:820:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:820:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:820:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:820:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:820:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:820:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:820:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:820:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:820:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:820:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:820:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:820:EDES NPP MS")
  field(INPB, "QUAD:LTUS:820:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:840:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:840:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:840:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:840:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:840:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:840:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:840:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:840:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:840:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:840:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:840:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:840:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:840:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:840:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:840:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:840:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:840:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:840:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:840:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:840:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:840:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:840:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:840:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:840:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:840:BMAX")
  field(DOL2, "QUAD:LTUS:840:BMAX")
  field(DOL3, "QUAD:LTUS:840:BMAX")
  field(DOL4, "QUAD:LTUS:840:BMIN")
  field(DOL5, "QUAD:LTUS:840:BMIN")
  field(DOL6, "QUAD:LTUS:840:BMIN")
  field(LNK1, "QUAD:LTUS:840:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:840:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:840:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:840:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:840:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:840:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:840:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:840:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:840:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:840:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:840:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:840:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:840:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:840:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:840:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:840:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:840:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:840:EDES NPP MS")
  field(INPB, "QUAD:LTUS:840:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:860:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:860:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:860:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:860:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:860:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:860:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:860:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:860:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:860:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:860:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:860:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:860:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:860:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:860:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:860:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:860:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:860:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:860:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:860:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:860:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:860:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:860:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:860:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:860:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:860:BMAX")
  field(DOL2, "QUAD:LTUS:860:BMAX")
  field(DOL3, "QUAD:LTUS:860:BMAX")
  field(DOL4, "QUAD:LTUS:860:BMIN")
  field(DOL5, "QUAD:LTUS:860:BMIN")
  field(DOL6, "QUAD:LTUS:860:BMIN")
  field(LNK1, "QUAD:LTUS:860:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:860:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:860:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:860:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:860:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:860:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:860:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:860:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:860:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:860:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:860:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:860:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:860:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:860:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:860:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:860:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:860:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:860:EDES NPP MS")
  field(INPB, "QUAD:LTUS:860:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:880:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:880:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:880:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:880:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:880:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:880:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:880:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:880:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:880:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:880:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:880:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:880:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:880:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:880:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:880:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:880:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:880:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:880:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:880:BMAX")
  field(DOL2, "QUAD:LTUS:880:BMAX")
  field(DOL3, "QUAD:LTUS:880:BMAX")
  field(DOL4, "QUAD:LTUS:880:BMIN")
  field(DOL5, "QUAD:LTUS:880:BMIN")
  field(DOL6, "QUAD:LTUS:880:BMIN")
  field(LNK1, "QUAD:LTUS:880:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:880:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:880:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:880:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:880:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:LTUS:880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:880:EDES NPP MS")
  field(INPB, "QUAD:LTUS:880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:118:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:118:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:118:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:118:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:118:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:118:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:118:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:118:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:118:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:118:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:118:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:118:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:118:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:118:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:118:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:118:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:118:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:118:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:118:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:118:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:118:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:118:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:118:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:118:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:118:BMAX")
  field(DOL2, "XCOR:LTUS:118:BMAX")
  field(DOL3, "XCOR:LTUS:118:BMAX")
  field(DOL4, "XCOR:LTUS:118:BMIN")
  field(DOL5, "XCOR:LTUS:118:BMIN")
  field(DOL6, "XCOR:LTUS:118:BMIN")
  field(LNK1, "XCOR:LTUS:118:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:118:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:118:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:118:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:118:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:118:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:118:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:118:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:118:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:118:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:118:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:118:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:118:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:118:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:118:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:118:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:118:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:118:EDES NPP MS")
  field(INPB, "XCOR:LTUS:118:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:148:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:148:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:148:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:148:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:148:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:148:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:148:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:148:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:148:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:148:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:148:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:148:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:148:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:148:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:148:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:148:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:148:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:148:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:148:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:148:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:148:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:148:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:148:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:148:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:148:BMAX")
  field(DOL2, "XCOR:LTUS:148:BMAX")
  field(DOL3, "XCOR:LTUS:148:BMAX")
  field(DOL4, "XCOR:LTUS:148:BMIN")
  field(DOL5, "XCOR:LTUS:148:BMIN")
  field(DOL6, "XCOR:LTUS:148:BMIN")
  field(LNK1, "XCOR:LTUS:148:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:148:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:148:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:148:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:148:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:148:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:148:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:148:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:148:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:148:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:148:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:148:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:148:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:148:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:148:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:148:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:148:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:148:EDES NPP MS")
  field(INPB, "XCOR:LTUS:148:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:228:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:228:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:228:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:228:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:228:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:228:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:228:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:228:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:228:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:228:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:228:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:228:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:228:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:228:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:228:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:228:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:228:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:228:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:228:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:228:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:228:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:228:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:228:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:228:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:228:BMAX")
  field(DOL2, "XCOR:LTUS:228:BMAX")
  field(DOL3, "XCOR:LTUS:228:BMAX")
  field(DOL4, "XCOR:LTUS:228:BMIN")
  field(DOL5, "XCOR:LTUS:228:BMIN")
  field(DOL6, "XCOR:LTUS:228:BMIN")
  field(LNK1, "XCOR:LTUS:228:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:228:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:228:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:228:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:228:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:228:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:228:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:228:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:228:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:228:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:228:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:228:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:228:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:228:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:228:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:228:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:228:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:228:EDES NPP MS")
  field(INPB, "XCOR:LTUS:228:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:296:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:296:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:296:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:296:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:296:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:296:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:296:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:296:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:296:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:296:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:296:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:296:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:296:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:296:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:296:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:296:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:296:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:296:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:296:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:296:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:296:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:296:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:296:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:296:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:296:BMAX")
  field(DOL2, "XCOR:LTUS:296:BMAX")
  field(DOL3, "XCOR:LTUS:296:BMAX")
  field(DOL4, "XCOR:LTUS:296:BMIN")
  field(DOL5, "XCOR:LTUS:296:BMIN")
  field(DOL6, "XCOR:LTUS:296:BMIN")
  field(LNK1, "XCOR:LTUS:296:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:296:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:296:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:296:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:296:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:296:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:296:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:296:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:296:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:296:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:296:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:296:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:296:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:296:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:296:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:296:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:296:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:296:EDES NPP MS")
  field(INPB, "XCOR:LTUS:296:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:368:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:368:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:368:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:368:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:368:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:368:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:368:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:368:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:368:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:368:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:368:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:368:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:368:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:368:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:368:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:368:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:368:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:368:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:368:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:368:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:368:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:368:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:368:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:368:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:368:BMAX")
  field(DOL2, "XCOR:LTUS:368:BMAX")
  field(DOL3, "XCOR:LTUS:368:BMAX")
  field(DOL4, "XCOR:LTUS:368:BMIN")
  field(DOL5, "XCOR:LTUS:368:BMIN")
  field(DOL6, "XCOR:LTUS:368:BMIN")
  field(LNK1, "XCOR:LTUS:368:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:368:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:368:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:368:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:368:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:368:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:368:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:368:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:368:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:368:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:368:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:368:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:368:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:368:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:368:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:368:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:368:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:368:EDES NPP MS")
  field(INPB, "XCOR:LTUS:368:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:448:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:448:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:448:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:448:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:448:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:448:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:448:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:448:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:448:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:448:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:448:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:448:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:448:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:448:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:448:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:448:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:448:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:448:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:448:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:448:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:448:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:448:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:448:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:448:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:448:BMAX")
  field(DOL2, "XCOR:LTUS:448:BMAX")
  field(DOL3, "XCOR:LTUS:448:BMAX")
  field(DOL4, "XCOR:LTUS:448:BMIN")
  field(DOL5, "XCOR:LTUS:448:BMIN")
  field(DOL6, "XCOR:LTUS:448:BMIN")
  field(LNK1, "XCOR:LTUS:448:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:448:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:448:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:448:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:448:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:448:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:448:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:448:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:448:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:448:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:448:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:448:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:448:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:448:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:448:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:448:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:448:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:448:EDES NPP MS")
  field(INPB, "XCOR:LTUS:448:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:508:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:508:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:508:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:508:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:508:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:508:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:508:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:508:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:508:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:508:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:508:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:508:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:508:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:508:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:508:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:508:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:508:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:508:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:508:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:508:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:508:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:508:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:508:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:508:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:508:BMAX")
  field(DOL2, "XCOR:LTUS:508:BMAX")
  field(DOL3, "XCOR:LTUS:508:BMAX")
  field(DOL4, "XCOR:LTUS:508:BMIN")
  field(DOL5, "XCOR:LTUS:508:BMIN")
  field(DOL6, "XCOR:LTUS:508:BMIN")
  field(LNK1, "XCOR:LTUS:508:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:508:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:508:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:508:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:508:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:508:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:508:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:508:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:508:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:508:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:508:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:508:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:508:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:508:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:508:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:508:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:508:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:508:EDES NPP MS")
  field(INPB, "XCOR:LTUS:508:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:548:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:548:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:548:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:548:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:548:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:548:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:548:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:548:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:548:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:548:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:548:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:548:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:548:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:548:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:548:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:548:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:548:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:548:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:548:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:548:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:548:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:548:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:548:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:548:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:548:BMAX")
  field(DOL2, "XCOR:LTUS:548:BMAX")
  field(DOL3, "XCOR:LTUS:548:BMAX")
  field(DOL4, "XCOR:LTUS:548:BMIN")
  field(DOL5, "XCOR:LTUS:548:BMIN")
  field(DOL6, "XCOR:LTUS:548:BMIN")
  field(LNK1, "XCOR:LTUS:548:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:548:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:548:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:548:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:548:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:548:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:548:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:548:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:548:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:548:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:548:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:548:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:548:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:548:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:548:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:548:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:548:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:548:EDES NPP MS")
  field(INPB, "XCOR:LTUS:548:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:568:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:568:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:568:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:568:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:568:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:568:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:568:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:568:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:568:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:568:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:568:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:568:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:568:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:568:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:568:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:568:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:568:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:568:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:568:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:568:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:568:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:568:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:568:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:568:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:568:BMAX")
  field(DOL2, "XCOR:LTUS:568:BMAX")
  field(DOL3, "XCOR:LTUS:568:BMAX")
  field(DOL4, "XCOR:LTUS:568:BMIN")
  field(DOL5, "XCOR:LTUS:568:BMIN")
  field(DOL6, "XCOR:LTUS:568:BMIN")
  field(LNK1, "XCOR:LTUS:568:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:568:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:568:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:568:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:568:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:568:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:568:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:568:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:568:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:568:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:568:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:568:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:568:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:568:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:568:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:568:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:568:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:568:EDES NPP MS")
  field(INPB, "XCOR:LTUS:568:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:616:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:616:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:616:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:616:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:616:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:616:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:616:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:616:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:616:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:616:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:616:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:616:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:616:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:616:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:616:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:616:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:616:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:616:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:616:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:616:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:616:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:616:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:616:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:616:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:616:BMAX")
  field(DOL2, "XCOR:LTUS:616:BMAX")
  field(DOL3, "XCOR:LTUS:616:BMAX")
  field(DOL4, "XCOR:LTUS:616:BMIN")
  field(DOL5, "XCOR:LTUS:616:BMIN")
  field(DOL6, "XCOR:LTUS:616:BMIN")
  field(LNK1, "XCOR:LTUS:616:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:616:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:616:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:616:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:616:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:616:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:616:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:616:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:616:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:616:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:616:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:616:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:616:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:616:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:616:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:616:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:616:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:616:EDES NPP MS")
  field(INPB, "XCOR:LTUS:616:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:658:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:658:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:658:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:658:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:658:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:658:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:658:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:658:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:658:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:658:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:658:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:658:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:658:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:658:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:658:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:658:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:658:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:658:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:658:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:658:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:658:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:658:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:658:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:658:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:658:BMAX")
  field(DOL2, "XCOR:LTUS:658:BMAX")
  field(DOL3, "XCOR:LTUS:658:BMAX")
  field(DOL4, "XCOR:LTUS:658:BMIN")
  field(DOL5, "XCOR:LTUS:658:BMIN")
  field(DOL6, "XCOR:LTUS:658:BMIN")
  field(LNK1, "XCOR:LTUS:658:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:658:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:658:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:658:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:658:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:658:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:658:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:658:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:658:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:658:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:658:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:658:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:658:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:658:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:658:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:658:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:658:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:658:EDES NPP MS")
  field(INPB, "XCOR:LTUS:658:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:718:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:718:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:718:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:718:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:718:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:718:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:718:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:718:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:718:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:718:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:718:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:718:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:718:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:718:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:718:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:718:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:718:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:718:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:718:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:718:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:718:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:718:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:718:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:718:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:718:BMAX")
  field(DOL2, "XCOR:LTUS:718:BMAX")
  field(DOL3, "XCOR:LTUS:718:BMAX")
  field(DOL4, "XCOR:LTUS:718:BMIN")
  field(DOL5, "XCOR:LTUS:718:BMIN")
  field(DOL6, "XCOR:LTUS:718:BMIN")
  field(LNK1, "XCOR:LTUS:718:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:718:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:718:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:718:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:718:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:718:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:718:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:718:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:718:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:718:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:718:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:718:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:718:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:718:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:718:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:718:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:718:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:718:EDES NPP MS")
  field(INPB, "XCOR:LTUS:718:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:722:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:722:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:722:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:722:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:722:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:722:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:722:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:722:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:722:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:722:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:722:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:722:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:722:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:722:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:722:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:722:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:722:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:722:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:722:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:722:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:722:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:722:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:722:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:722:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:722:BMAX")
  field(DOL2, "XCOR:LTUS:722:BMAX")
  field(DOL3, "XCOR:LTUS:722:BMAX")
  field(DOL4, "XCOR:LTUS:722:BMIN")
  field(DOL5, "XCOR:LTUS:722:BMIN")
  field(DOL6, "XCOR:LTUS:722:BMIN")
  field(LNK1, "XCOR:LTUS:722:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:722:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:722:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:722:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:722:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:722:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:722:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:722:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:722:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:722:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:722:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:722:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:722:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:722:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:722:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:722:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:722:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:722:EDES NPP MS")
  field(INPB, "XCOR:LTUS:722:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:738:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:738:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:738:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:738:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:738:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:738:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:738:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:738:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:738:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:738:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:738:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:738:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:738:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:738:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:738:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:738:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:738:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:738:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:738:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:738:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:738:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:738:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:738:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:738:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:738:BMAX")
  field(DOL2, "XCOR:LTUS:738:BMAX")
  field(DOL3, "XCOR:LTUS:738:BMAX")
  field(DOL4, "XCOR:LTUS:738:BMIN")
  field(DOL5, "XCOR:LTUS:738:BMIN")
  field(DOL6, "XCOR:LTUS:738:BMIN")
  field(LNK1, "XCOR:LTUS:738:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:738:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:738:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:738:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:738:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:738:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:738:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:738:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:738:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:738:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:738:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:738:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:738:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:738:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:738:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:738:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:738:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:738:EDES NPP MS")
  field(INPB, "XCOR:LTUS:738:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:758:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:758:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:758:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:758:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:758:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:758:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:758:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:758:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:758:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:758:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:758:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:758:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:758:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:758:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:758:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:758:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:758:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:758:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:758:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:758:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:758:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:758:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:758:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:758:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:758:BMAX")
  field(DOL2, "XCOR:LTUS:758:BMAX")
  field(DOL3, "XCOR:LTUS:758:BMAX")
  field(DOL4, "XCOR:LTUS:758:BMIN")
  field(DOL5, "XCOR:LTUS:758:BMIN")
  field(DOL6, "XCOR:LTUS:758:BMIN")
  field(LNK1, "XCOR:LTUS:758:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:758:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:758:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:758:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:758:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:758:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:758:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:758:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:758:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:758:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:758:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:758:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:758:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:758:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:758:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:758:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:758:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:758:EDES NPP MS")
  field(INPB, "XCOR:LTUS:758:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:768:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:768:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:768:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:768:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:768:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:768:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:768:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:768:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:768:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:768:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:768:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:768:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:768:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:768:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:768:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:768:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:768:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:768:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:768:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:768:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:768:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:768:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:768:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:768:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:768:BMAX")
  field(DOL2, "XCOR:LTUS:768:BMAX")
  field(DOL3, "XCOR:LTUS:768:BMAX")
  field(DOL4, "XCOR:LTUS:768:BMIN")
  field(DOL5, "XCOR:LTUS:768:BMIN")
  field(DOL6, "XCOR:LTUS:768:BMIN")
  field(LNK1, "XCOR:LTUS:768:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:768:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:768:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:768:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:768:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:768:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:768:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:768:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:768:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:768:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:768:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:768:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:768:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:768:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:768:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:768:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:768:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:768:EDES NPP MS")
  field(INPB, "XCOR:LTUS:768:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:826:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:826:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:826:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:826:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:826:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:826:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:826:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:826:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:826:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:826:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:826:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:826:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:826:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:826:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:826:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:826:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:826:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:826:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:826:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:826:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:826:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:826:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:826:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:826:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:826:BMAX")
  field(DOL2, "XCOR:LTUS:826:BMAX")
  field(DOL3, "XCOR:LTUS:826:BMAX")
  field(DOL4, "XCOR:LTUS:826:BMIN")
  field(DOL5, "XCOR:LTUS:826:BMIN")
  field(DOL6, "XCOR:LTUS:826:BMIN")
  field(LNK1, "XCOR:LTUS:826:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:826:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:826:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:826:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:826:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:826:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:826:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:826:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:826:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:826:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:826:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:826:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:826:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:826:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:826:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:826:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:826:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:826:EDES NPP MS")
  field(INPB, "XCOR:LTUS:826:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:LTUS:858:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "XCOR:LTUS:858:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:LTUS:858:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:LTUS:858:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:LTUS:858:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:LTUS:858:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:LTUS:858:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:LTUS:858:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:LTUS:858:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:LTUS:858:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:LTUS:858:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:LTUS:858:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:LTUS:858:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:LTUS:858:EDES.PROC PP")
    field(LNK2, "XCOR:LTUS:858:EACT.PROC PP")
    field(LNK3, "XCOR:LTUS:858:EERR.DISA PP")
    field(LNK4, "XCOR:LTUS:858:ECON.PROC PP")
    field(LNK5, "XCOR:LTUS:858:BMAGX.PROC PP")
    field(LNK6, "XCOR:LTUS:858:BMAGY.PROC PP")
    field(LNK7, "XCOR:LTUS:858:BLEM.PROC PP")
    field(LNK8, "XCOR:LTUS:858:BMOD.PROC PP")
    field(LNK9, "XCOR:LTUS:858:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:LTUS:858:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:LTUS:858:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:LTUS:858:BMAX")
  field(DOL2, "XCOR:LTUS:858:BMAX")
  field(DOL3, "XCOR:LTUS:858:BMAX")
  field(DOL4, "XCOR:LTUS:858:BMIN")
  field(DOL5, "XCOR:LTUS:858:BMIN")
  field(DOL6, "XCOR:LTUS:858:BMIN")
  field(LNK1, "XCOR:LTUS:858:BMAGX.HOPR")
  field(LNK2, "XCOR:LTUS:858:BMAGY.HOPR")
  field(LNK3, "XCOR:LTUS:858:BLEM.HOPR")
  field(LNK4, "XCOR:LTUS:858:BMAGX.LOPR PP")
  field(LNK5, "XCOR:LTUS:858:BMAGY.LOPR PP")
  field(LNK6, "XCOR:LTUS:858:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:858:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:LTUS:858:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:LTUS:858:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:LTUS:858:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:LTUS:858:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:858:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:858:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:858:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:LTUS:858:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:LTUS:858:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:LTUS:858:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:LTUS:858:EDES NPP MS")
  field(INPB, "XCOR:LTUS:858:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:111:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:111:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:111:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:111:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:111:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:111:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:111:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:111:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:111:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:111:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:111:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:111:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:111:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:111:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:111:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:111:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:111:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:111:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:111:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:111:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:111:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:111:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:111:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:111:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:111:BMAX")
  field(DOL2, "YCOR:LTUS:111:BMAX")
  field(DOL3, "YCOR:LTUS:111:BMAX")
  field(DOL4, "YCOR:LTUS:111:BMIN")
  field(DOL5, "YCOR:LTUS:111:BMIN")
  field(DOL6, "YCOR:LTUS:111:BMIN")
  field(LNK1, "YCOR:LTUS:111:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:111:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:111:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:111:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:111:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:111:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:111:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:111:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:111:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:111:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:111:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:111:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:111:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:111:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:111:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:111:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:111:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:111:EDES NPP MS")
  field(INPB, "YCOR:LTUS:111:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:183:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:183:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:183:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:183:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:183:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:183:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:183:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:183:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:183:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:183:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:183:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:183:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:183:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:183:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:183:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:183:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:183:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:183:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:183:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:183:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:183:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:183:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:183:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:183:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:183:BMAX")
  field(DOL2, "YCOR:LTUS:183:BMAX")
  field(DOL3, "YCOR:LTUS:183:BMAX")
  field(DOL4, "YCOR:LTUS:183:BMIN")
  field(DOL5, "YCOR:LTUS:183:BMIN")
  field(DOL6, "YCOR:LTUS:183:BMIN")
  field(LNK1, "YCOR:LTUS:183:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:183:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:183:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:183:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:183:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:183:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:183:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:183:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:183:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:183:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:183:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:183:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:183:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:183:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:183:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:183:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:183:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:183:EDES NPP MS")
  field(INPB, "YCOR:LTUS:183:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:267:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:267:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:267:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:267:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:267:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:267:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:267:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:267:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:267:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:267:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:267:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:267:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:267:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:267:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:267:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:267:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:267:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:267:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:267:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:267:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:267:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:267:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:267:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:267:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:267:BMAX")
  field(DOL2, "YCOR:LTUS:267:BMAX")
  field(DOL3, "YCOR:LTUS:267:BMAX")
  field(DOL4, "YCOR:LTUS:267:BMIN")
  field(DOL5, "YCOR:LTUS:267:BMIN")
  field(DOL6, "YCOR:LTUS:267:BMIN")
  field(LNK1, "YCOR:LTUS:267:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:267:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:267:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:267:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:267:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:267:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:267:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:267:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:267:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:267:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:267:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:267:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:267:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:267:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:267:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:267:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:267:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:267:EDES NPP MS")
  field(INPB, "YCOR:LTUS:267:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:341:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:341:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:341:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:341:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:341:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:341:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:341:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:341:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:341:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:341:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:341:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:341:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:341:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:341:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:341:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:341:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:341:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:341:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:341:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:341:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:341:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:341:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:341:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:341:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:341:BMAX")
  field(DOL2, "YCOR:LTUS:341:BMAX")
  field(DOL3, "YCOR:LTUS:341:BMAX")
  field(DOL4, "YCOR:LTUS:341:BMIN")
  field(DOL5, "YCOR:LTUS:341:BMIN")
  field(DOL6, "YCOR:LTUS:341:BMIN")
  field(LNK1, "YCOR:LTUS:341:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:341:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:341:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:341:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:341:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:341:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:341:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:341:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:341:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:341:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:341:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:341:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:341:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:341:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:341:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:341:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:341:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:341:EDES NPP MS")
  field(INPB, "YCOR:LTUS:341:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:427:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:427:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:427:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:427:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:427:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:427:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:427:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:427:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:427:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:427:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:427:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:427:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:427:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:427:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:427:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:427:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:427:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:427:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:427:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:427:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:427:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:427:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:427:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:427:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:427:BMAX")
  field(DOL2, "YCOR:LTUS:427:BMAX")
  field(DOL3, "YCOR:LTUS:427:BMAX")
  field(DOL4, "YCOR:LTUS:427:BMIN")
  field(DOL5, "YCOR:LTUS:427:BMIN")
  field(DOL6, "YCOR:LTUS:427:BMIN")
  field(LNK1, "YCOR:LTUS:427:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:427:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:427:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:427:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:427:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:427:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:427:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:427:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:427:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:427:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:427:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:427:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:427:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:427:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:427:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:427:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:427:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:427:EDES NPP MS")
  field(INPB, "YCOR:LTUS:427:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:471:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:471:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:471:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:471:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:471:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:471:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:471:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:471:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:471:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:471:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:471:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:471:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:471:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:471:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:471:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:471:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:471:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:471:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:471:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:471:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:471:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:471:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:471:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:471:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:471:BMAX")
  field(DOL2, "YCOR:LTUS:471:BMAX")
  field(DOL3, "YCOR:LTUS:471:BMAX")
  field(DOL4, "YCOR:LTUS:471:BMIN")
  field(DOL5, "YCOR:LTUS:471:BMIN")
  field(DOL6, "YCOR:LTUS:471:BMIN")
  field(LNK1, "YCOR:LTUS:471:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:471:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:471:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:471:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:471:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:471:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:471:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:471:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:471:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:471:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:471:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:471:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:471:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:471:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:471:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:471:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:471:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:471:EDES NPP MS")
  field(INPB, "YCOR:LTUS:471:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:499:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:499:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:499:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:499:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:499:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:499:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:499:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:499:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:499:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:499:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:499:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:499:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:499:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:499:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:499:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:499:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:499:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:499:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:499:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:499:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:499:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:499:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:499:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:499:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:499:BMAX")
  field(DOL2, "YCOR:LTUS:499:BMAX")
  field(DOL3, "YCOR:LTUS:499:BMAX")
  field(DOL4, "YCOR:LTUS:499:BMIN")
  field(DOL5, "YCOR:LTUS:499:BMIN")
  field(DOL6, "YCOR:LTUS:499:BMIN")
  field(LNK1, "YCOR:LTUS:499:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:499:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:499:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:499:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:499:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:499:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:499:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:499:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:499:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:499:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:499:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:499:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:499:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:499:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:499:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:499:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:499:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:499:EDES NPP MS")
  field(INPB, "YCOR:LTUS:499:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:547:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:547:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:547:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:547:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:547:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:547:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:547:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:547:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:547:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:547:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:547:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:547:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:547:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:547:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:547:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:547:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:547:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:547:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:547:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:547:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:547:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:547:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:547:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:547:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:547:BMAX")
  field(DOL2, "YCOR:LTUS:547:BMAX")
  field(DOL3, "YCOR:LTUS:547:BMAX")
  field(DOL4, "YCOR:LTUS:547:BMIN")
  field(DOL5, "YCOR:LTUS:547:BMIN")
  field(DOL6, "YCOR:LTUS:547:BMIN")
  field(LNK1, "YCOR:LTUS:547:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:547:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:547:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:547:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:547:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:547:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:547:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:547:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:547:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:547:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:547:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:547:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:547:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:547:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:547:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:547:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:547:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:547:EDES NPP MS")
  field(INPB, "YCOR:LTUS:547:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:561:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:561:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:561:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:561:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:561:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:561:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:561:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:561:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:561:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:561:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:561:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:561:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:561:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:561:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:561:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:561:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:561:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:561:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:561:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:561:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:561:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:561:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:561:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:561:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:561:BMAX")
  field(DOL2, "YCOR:LTUS:561:BMAX")
  field(DOL3, "YCOR:LTUS:561:BMAX")
  field(DOL4, "YCOR:LTUS:561:BMIN")
  field(DOL5, "YCOR:LTUS:561:BMIN")
  field(DOL6, "YCOR:LTUS:561:BMIN")
  field(LNK1, "YCOR:LTUS:561:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:561:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:561:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:561:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:561:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:561:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:561:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:561:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:561:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:561:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:561:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:561:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:561:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:561:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:561:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:561:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:561:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:561:EDES NPP MS")
  field(INPB, "YCOR:LTUS:561:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:577:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:577:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:577:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:577:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:577:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:577:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:577:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:577:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:577:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:577:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:577:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:577:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:577:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:577:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:577:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:577:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:577:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:577:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:577:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:577:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:577:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:577:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:577:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:577:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:577:BMAX")
  field(DOL2, "YCOR:LTUS:577:BMAX")
  field(DOL3, "YCOR:LTUS:577:BMAX")
  field(DOL4, "YCOR:LTUS:577:BMIN")
  field(DOL5, "YCOR:LTUS:577:BMIN")
  field(DOL6, "YCOR:LTUS:577:BMIN")
  field(LNK1, "YCOR:LTUS:577:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:577:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:577:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:577:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:577:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:577:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:577:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:577:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:577:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:577:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:577:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:577:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:577:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:577:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:577:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:577:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:577:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:577:EDES NPP MS")
  field(INPB, "YCOR:LTUS:577:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:641:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:641:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:641:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:641:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:641:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:641:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:641:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:641:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:641:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:641:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:641:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:641:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:641:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:641:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:641:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:641:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:641:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:641:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:641:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:641:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:641:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:641:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:641:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:641:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:641:BMAX")
  field(DOL2, "YCOR:LTUS:641:BMAX")
  field(DOL3, "YCOR:LTUS:641:BMAX")
  field(DOL4, "YCOR:LTUS:641:BMIN")
  field(DOL5, "YCOR:LTUS:641:BMIN")
  field(DOL6, "YCOR:LTUS:641:BMIN")
  field(LNK1, "YCOR:LTUS:641:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:641:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:641:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:641:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:641:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:641:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:641:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:641:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:641:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:641:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:641:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:641:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:641:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:641:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:641:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:641:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:641:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:641:EDES NPP MS")
  field(INPB, "YCOR:LTUS:641:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:677:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:677:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:677:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:677:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:677:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:677:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:677:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:677:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:677:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:677:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:677:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:677:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:677:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:677:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:677:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:677:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:677:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:677:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:677:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:677:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:677:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:677:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:677:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:677:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:677:BMAX")
  field(DOL2, "YCOR:LTUS:677:BMAX")
  field(DOL3, "YCOR:LTUS:677:BMAX")
  field(DOL4, "YCOR:LTUS:677:BMIN")
  field(DOL5, "YCOR:LTUS:677:BMIN")
  field(DOL6, "YCOR:LTUS:677:BMIN")
  field(LNK1, "YCOR:LTUS:677:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:677:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:677:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:677:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:677:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:677:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:677:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:677:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:677:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:677:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:677:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:677:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:677:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:677:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:677:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:677:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:677:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:677:EDES NPP MS")
  field(INPB, "YCOR:LTUS:677:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:721:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:721:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:721:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:721:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:721:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:721:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:721:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:721:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:721:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:721:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:721:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:721:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:721:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:721:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:721:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:721:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:721:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:721:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:721:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:721:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:721:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:721:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:721:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:721:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:721:BMAX")
  field(DOL2, "YCOR:LTUS:721:BMAX")
  field(DOL3, "YCOR:LTUS:721:BMAX")
  field(DOL4, "YCOR:LTUS:721:BMIN")
  field(DOL5, "YCOR:LTUS:721:BMIN")
  field(DOL6, "YCOR:LTUS:721:BMIN")
  field(LNK1, "YCOR:LTUS:721:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:721:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:721:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:721:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:721:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:721:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:721:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:721:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:721:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:721:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:721:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:721:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:721:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:721:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:721:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:721:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:721:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:721:EDES NPP MS")
  field(INPB, "YCOR:LTUS:721:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:729:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:729:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:729:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:729:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:729:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:729:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:729:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:729:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:729:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:729:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:729:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:729:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:729:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:729:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:729:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:729:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:729:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:729:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:729:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:729:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:729:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:729:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:729:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:729:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:729:BMAX")
  field(DOL2, "YCOR:LTUS:729:BMAX")
  field(DOL3, "YCOR:LTUS:729:BMAX")
  field(DOL4, "YCOR:LTUS:729:BMIN")
  field(DOL5, "YCOR:LTUS:729:BMIN")
  field(DOL6, "YCOR:LTUS:729:BMIN")
  field(LNK1, "YCOR:LTUS:729:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:729:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:729:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:729:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:729:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:729:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:729:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:729:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:729:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:729:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:729:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:729:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:729:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:729:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:729:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:729:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:729:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:729:EDES NPP MS")
  field(INPB, "YCOR:LTUS:729:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:749:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:749:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:749:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:749:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:749:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:749:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:749:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:749:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:749:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:749:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:749:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:749:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:749:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:749:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:749:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:749:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:749:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:749:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:749:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:749:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:749:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:749:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:749:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:749:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:749:BMAX")
  field(DOL2, "YCOR:LTUS:749:BMAX")
  field(DOL3, "YCOR:LTUS:749:BMAX")
  field(DOL4, "YCOR:LTUS:749:BMIN")
  field(DOL5, "YCOR:LTUS:749:BMIN")
  field(DOL6, "YCOR:LTUS:749:BMIN")
  field(LNK1, "YCOR:LTUS:749:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:749:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:749:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:749:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:749:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:749:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:749:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:749:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:749:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:749:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:749:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:749:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:749:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:749:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:749:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:749:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:749:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:749:EDES NPP MS")
  field(INPB, "YCOR:LTUS:749:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:767:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:767:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:767:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:767:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:767:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:767:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:767:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:767:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:767:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:767:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:767:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:767:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:767:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:767:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:767:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:767:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:767:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:767:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:767:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:767:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:767:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:767:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:767:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:767:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:767:BMAX")
  field(DOL2, "YCOR:LTUS:767:BMAX")
  field(DOL3, "YCOR:LTUS:767:BMAX")
  field(DOL4, "YCOR:LTUS:767:BMIN")
  field(DOL5, "YCOR:LTUS:767:BMIN")
  field(DOL6, "YCOR:LTUS:767:BMIN")
  field(LNK1, "YCOR:LTUS:767:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:767:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:767:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:767:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:767:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:767:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:767:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:767:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:767:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:767:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:767:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:767:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:767:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:767:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:767:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:767:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:767:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:767:EDES NPP MS")
  field(INPB, "YCOR:LTUS:767:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:777:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:777:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:777:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:777:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:777:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:777:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:777:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:777:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:777:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:777:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:777:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:777:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:777:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:777:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:777:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:777:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:777:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:777:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:777:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:777:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:777:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:777:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:777:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:777:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:777:BMAX")
  field(DOL2, "YCOR:LTUS:777:BMAX")
  field(DOL3, "YCOR:LTUS:777:BMAX")
  field(DOL4, "YCOR:LTUS:777:BMIN")
  field(DOL5, "YCOR:LTUS:777:BMIN")
  field(DOL6, "YCOR:LTUS:777:BMIN")
  field(LNK1, "YCOR:LTUS:777:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:777:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:777:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:777:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:777:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:777:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:777:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:777:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:777:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:777:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:777:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:777:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:777:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:777:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:777:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:777:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:777:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:777:EDES NPP MS")
  field(INPB, "YCOR:LTUS:777:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:839:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:839:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:839:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:839:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:839:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:839:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:839:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:839:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:839:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:839:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:839:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:839:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:839:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:839:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:839:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:839:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:839:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:839:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:839:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:839:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:839:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:839:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:839:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:839:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:839:BMAX")
  field(DOL2, "YCOR:LTUS:839:BMAX")
  field(DOL3, "YCOR:LTUS:839:BMAX")
  field(DOL4, "YCOR:LTUS:839:BMIN")
  field(DOL5, "YCOR:LTUS:839:BMIN")
  field(DOL6, "YCOR:LTUS:839:BMIN")
  field(LNK1, "YCOR:LTUS:839:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:839:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:839:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:839:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:839:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:839:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:839:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:839:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:839:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:839:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:839:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:839:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:839:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:839:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:839:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:839:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:839:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:839:EDES NPP MS")
  field(INPB, "YCOR:LTUS:839:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:LTUS:877:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "YCOR:LTUS:877:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:LTUS:877:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:LTUS:877:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:LTUS:877:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:LTUS:877:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:LTUS:877:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:LTUS:877:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:LTUS:877:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:LTUS:877:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:LTUS:877:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:LTUS:877:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:LTUS:877:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:LTUS:877:EDES.PROC PP")
    field(LNK2, "YCOR:LTUS:877:EACT.PROC PP")
    field(LNK3, "YCOR:LTUS:877:EERR.DISA PP")
    field(LNK4, "YCOR:LTUS:877:ECON.PROC PP")
    field(LNK5, "YCOR:LTUS:877:BMAGX.PROC PP")
    field(LNK6, "YCOR:LTUS:877:BMAGY.PROC PP")
    field(LNK7, "YCOR:LTUS:877:BLEM.PROC PP")
    field(LNK8, "YCOR:LTUS:877:BMOD.PROC PP")
    field(LNK9, "YCOR:LTUS:877:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:LTUS:877:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:LTUS:877:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:LTUS:877:BMAX")
  field(DOL2, "YCOR:LTUS:877:BMAX")
  field(DOL3, "YCOR:LTUS:877:BMAX")
  field(DOL4, "YCOR:LTUS:877:BMIN")
  field(DOL5, "YCOR:LTUS:877:BMIN")
  field(DOL6, "YCOR:LTUS:877:BMIN")
  field(LNK1, "YCOR:LTUS:877:BMAGX.HOPR")
  field(LNK2, "YCOR:LTUS:877:BMAGY.HOPR")
  field(LNK3, "YCOR:LTUS:877:BLEM.HOPR")
  field(LNK4, "YCOR:LTUS:877:BMAGX.LOPR PP")
  field(LNK5, "YCOR:LTUS:877:BMAGY.LOPR PP")
  field(LNK6, "YCOR:LTUS:877:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:877:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:LTUS:877:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:LTUS:877:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:LTUS:877:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:LTUS:877:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:877:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:877:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:877:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:LTUS:877:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:LTUS:877:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:LTUS:877:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:LTUS:877:EDES NPP MS")
  field(INPB, "YCOR:LTUS:877:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:LTUH:340:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "KICK:LTUH:340:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:LTUH:340:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:LTUH:340:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:LTUH:340:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:LTUH:340:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:LTUH:340:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:LTUH:340:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:LTUH:340:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:LTUH:340:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:LTUH:340:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:LTUH:340:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:LTUH:340:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:LTUH:340:EDES.PROC PP")
    field(LNK2, "KICK:LTUH:340:EACT.PROC PP")
    field(LNK3, "KICK:LTUH:340:EERR.DISA PP")
    field(LNK4, "KICK:LTUH:340:ECON.PROC PP")
    field(LNK5, "KICK:LTUH:340:BMAGX.PROC PP")
    field(LNK6, "KICK:LTUH:340:BMAGY.PROC PP")
    field(LNK7, "KICK:LTUH:340:BLEM.PROC PP")
    field(LNK8, "KICK:LTUH:340:BMOD.PROC PP")
    field(LNK9, "KICK:LTUH:340:EDESSAVE.PROC PP")
    field(LNKA, "KICK:LTUH:340:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:LTUH:340:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:LTUH:340:BMAX")
  field(DOL2, "KICK:LTUH:340:BMAX")
  field(DOL3, "KICK:LTUH:340:BMAX")
  field(DOL4, "KICK:LTUH:340:BMIN")
  field(DOL5, "KICK:LTUH:340:BMIN")
  field(DOL6, "KICK:LTUH:340:BMIN")
  field(LNK1, "KICK:LTUH:340:BMAGX.HOPR")
  field(LNK2, "KICK:LTUH:340:BMAGY.HOPR")
  field(LNK3, "KICK:LTUH:340:BLEM.HOPR")
  field(LNK4, "KICK:LTUH:340:BMAGX.LOPR PP")
  field(LNK5, "KICK:LTUH:340:BMAGY.LOPR PP")
  field(LNK6, "KICK:LTUH:340:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:LTUH:340:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:LTUH:340:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:LTUH:340:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:LTUH:340:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:LTUH:340:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LTUH:340:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "KICK:LTUH:320:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LTUH:340:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "KICK:LTUH:320:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:LTUH:340:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LTUH:340:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "KICK:LTUH:320:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:LTUH:340:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:LTUH:340:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:LTUH:340:EDES NPP MS")
  field(INPB, "KICK:LTUH:340:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:175:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:175:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:175:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:175:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:175:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:175:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:175:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:175:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:175:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:175:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:175:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:175:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:175:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:175:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:175:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:175:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:175:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:175:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:175:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:175:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:175:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:175:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:175:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:175:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:175:BMAX")
  field(DOL2, "BEND:LTUH:175:BMAX")
  field(DOL3, "BEND:LTUH:175:BMAX")
  field(DOL4, "BEND:LTUH:175:BMIN")
  field(DOL5, "BEND:LTUH:175:BMIN")
  field(DOL6, "BEND:LTUH:175:BMIN")
  field(LNK1, "BEND:LTUH:175:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:175:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:175:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:175:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:175:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:175:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:175:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:175:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:175:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:175:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:175:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:175:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUH:125:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:175:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:125:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:175:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:175:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:125:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:175:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:175:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:175:EDES NPP MS")
  field(INPB, "BEND:LTUH:175:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:300:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:300:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:300:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:300:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:300:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:300:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:300:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:300:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:300:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:300:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:300:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:300:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:300:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:300:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:300:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:300:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:300:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:300:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:300:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:300:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:300:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:300:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:300:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:300:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:300:BMAX")
  field(DOL2, "BEND:LTUH:300:BMAX")
  field(DOL3, "BEND:LTUH:300:BMAX")
  field(DOL4, "BEND:LTUH:300:BMIN")
  field(DOL5, "BEND:LTUH:300:BMIN")
  field(DOL6, "BEND:LTUH:300:BMIN")
  field(LNK1, "BEND:LTUH:300:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:300:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:300:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:300:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:300:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:300:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:300:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:300:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:300:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:300:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:300:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:300:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUH:301:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:300:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:301:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:300:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:300:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:301:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:300:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:300:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:300:EDES NPP MS")
  field(INPB, "BEND:LTUH:300:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:302:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:302:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:302:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:302:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:302:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:302:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:302:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:302:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:302:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:302:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:302:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:302:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:302:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:302:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:302:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:302:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:302:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:302:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:302:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:302:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:302:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:302:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:302:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:302:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:302:BMAX")
  field(DOL2, "BEND:LTUH:302:BMAX")
  field(DOL3, "BEND:LTUH:302:BMAX")
  field(DOL4, "BEND:LTUH:302:BMIN")
  field(DOL5, "BEND:LTUH:302:BMIN")
  field(DOL6, "BEND:LTUH:302:BMIN")
  field(LNK1, "BEND:LTUH:302:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:302:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:302:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:302:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:302:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:302:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:302:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:302:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:302:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:302:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:302:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:302:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUH:301:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:302:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:301:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:302:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:302:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:301:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:302:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:302:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:302:EDES NPP MS")
  field(INPB, "BEND:LTUH:302:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:303:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:303:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:303:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:303:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:303:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:303:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:303:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:303:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:303:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:303:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:303:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:303:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:303:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:303:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:303:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:303:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:303:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:303:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:303:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:303:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:303:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:303:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:303:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:303:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:303:BMAX")
  field(DOL2, "BEND:LTUH:303:BMAX")
  field(DOL3, "BEND:LTUH:303:BMAX")
  field(DOL4, "BEND:LTUH:303:BMIN")
  field(DOL5, "BEND:LTUH:303:BMIN")
  field(DOL6, "BEND:LTUH:303:BMIN")
  field(LNK1, "BEND:LTUH:303:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:303:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:303:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:303:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:303:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:303:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:303:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:303:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:303:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:303:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:303:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:303:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUH:301:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:303:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:301:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:303:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:303:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:301:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:303:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:303:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:303:EDES NPP MS")
  field(INPB, "BEND:LTUH:303:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:375:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:375:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:375:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:375:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:375:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:375:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:375:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:375:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:375:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:375:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:375:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:375:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:375:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:375:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:375:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:375:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:375:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:375:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:375:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:375:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:375:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:375:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:375:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:375:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:375:BMAX")
  field(DOL2, "BEND:LTUH:375:BMAX")
  field(DOL3, "BEND:LTUH:375:BMAX")
  field(DOL4, "BEND:LTUH:375:BMIN")
  field(DOL5, "BEND:LTUH:375:BMIN")
  field(DOL6, "BEND:LTUH:375:BMIN")
  field(LNK1, "BEND:LTUH:375:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:375:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:375:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:375:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:375:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:375:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:375:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:375:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:375:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:375:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:375:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:375:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUH:376:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:375:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:376:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:375:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:375:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:376:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:375:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:375:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:375:EDES NPP MS")
  field(INPB, "BEND:LTUH:375:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:377:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:377:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:377:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:377:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:377:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:377:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:377:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:377:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:377:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:377:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:377:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:377:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:377:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:377:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:377:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:377:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:377:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:377:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:377:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:377:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:377:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:377:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:377:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:377:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:377:BMAX")
  field(DOL2, "BEND:LTUH:377:BMAX")
  field(DOL3, "BEND:LTUH:377:BMAX")
  field(DOL4, "BEND:LTUH:377:BMIN")
  field(DOL5, "BEND:LTUH:377:BMIN")
  field(DOL6, "BEND:LTUH:377:BMIN")
  field(LNK1, "BEND:LTUH:377:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:377:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:377:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:377:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:377:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:377:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:377:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:377:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:377:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:377:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:377:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:377:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUH:376:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:377:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:376:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:377:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:377:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:376:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:377:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:377:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:377:EDES NPP MS")
  field(INPB, "BEND:LTUH:377:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:378:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:378:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:378:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:378:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:378:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:378:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:378:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:378:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:378:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:378:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:378:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:378:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:378:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:378:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:378:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:378:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:378:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:378:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:378:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:378:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:378:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:378:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:378:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:378:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:378:BMAX")
  field(DOL2, "BEND:LTUH:378:BMAX")
  field(DOL3, "BEND:LTUH:378:BMAX")
  field(DOL4, "BEND:LTUH:378:BMIN")
  field(DOL5, "BEND:LTUH:378:BMIN")
  field(DOL6, "BEND:LTUH:378:BMIN")
  field(LNK1, "BEND:LTUH:378:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:378:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:378:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:378:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:378:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:378:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:378:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:378:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:378:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:378:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:378:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:378:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUH:376:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:378:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:376:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:378:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:378:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:376:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:378:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:378:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:378:EDES NPP MS")
  field(INPB, "BEND:LTUH:378:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:505:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:505:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:505:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:505:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:505:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:505:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:505:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:505:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:505:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:505:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:505:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:505:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:505:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:505:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:505:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:505:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:505:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:505:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:505:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:505:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:505:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:505:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:505:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:505:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:505:BMAX")
  field(DOL2, "BEND:LTUH:505:BMAX")
  field(DOL3, "BEND:LTUH:505:BMAX")
  field(DOL4, "BEND:LTUH:505:BMIN")
  field(DOL5, "BEND:LTUH:505:BMIN")
  field(DOL6, "BEND:LTUH:505:BMIN")
  field(LNK1, "BEND:LTUH:505:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:505:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:505:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:505:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:505:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:505:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:505:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:505:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:505:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:505:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:505:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:505:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUH:506:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:505:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:506:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:505:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:505:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:506:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:505:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:505:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:505:EDES NPP MS")
  field(INPB, "BEND:LTUH:505:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:507:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:507:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:507:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:507:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:507:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:507:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:507:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:507:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:507:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:507:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:507:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:507:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:507:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:507:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:507:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:507:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:507:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:507:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:507:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:507:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:507:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:507:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:507:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:507:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:507:BMAX")
  field(DOL2, "BEND:LTUH:507:BMAX")
  field(DOL3, "BEND:LTUH:507:BMAX")
  field(DOL4, "BEND:LTUH:507:BMIN")
  field(DOL5, "BEND:LTUH:507:BMIN")
  field(DOL6, "BEND:LTUH:507:BMIN")
  field(LNK1, "BEND:LTUH:507:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:507:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:507:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:507:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:507:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:507:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:507:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:507:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:507:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:507:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:507:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:507:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUH:506:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:507:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:506:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:507:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:507:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:506:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:507:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:507:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:507:EDES NPP MS")
  field(INPB, "BEND:LTUH:507:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:508:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:508:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:508:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:508:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:508:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:508:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:508:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:508:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:508:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:508:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:508:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:508:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:508:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:508:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:508:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:508:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:508:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:508:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:508:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:508:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:508:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:508:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:508:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:508:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:508:BMAX")
  field(DOL2, "BEND:LTUH:508:BMAX")
  field(DOL3, "BEND:LTUH:508:BMAX")
  field(DOL4, "BEND:LTUH:508:BMIN")
  field(DOL5, "BEND:LTUH:508:BMIN")
  field(DOL6, "BEND:LTUH:508:BMIN")
  field(LNK1, "BEND:LTUH:508:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:508:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:508:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:508:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:508:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:508:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:508:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:508:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:508:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:508:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:508:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:508:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUH:506:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:508:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:506:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:508:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:508:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUH:506:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:508:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:508:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:508:EDES NPP MS")
  field(INPB, "BEND:LTUH:508:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:150:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:150:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:150:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:150:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:150:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:150:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:150:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:150:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:150:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:150:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:150:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:150:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:150:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:150:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:150:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:150:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:150:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:150:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:150:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:150:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:150:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:150:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:150:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:150:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:150:BMAX")
  field(DOL2, "QUAD:LTUH:150:BMAX")
  field(DOL3, "QUAD:LTUH:150:BMAX")
  field(DOL4, "QUAD:LTUH:150:BMIN")
  field(DOL5, "QUAD:LTUH:150:BMIN")
  field(DOL6, "QUAD:LTUH:150:BMIN")
  field(LNK1, "QUAD:LTUH:150:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:150:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:150:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:150:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:150:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:150:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:150:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:150:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:150:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:150:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:150:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:150:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:130:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:150:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:130:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:150:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:150:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:130:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:150:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:150:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:150:EDES NPP MS")
  field(INPB, "QUAD:LTUH:150:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:170:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:170:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:170:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:170:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:170:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:170:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:170:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:170:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:170:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:170:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:170:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:170:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:170:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:170:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:170:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:170:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:170:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:170:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:170:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:170:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:170:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:170:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:170:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:170:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:170:BMAX")
  field(DOL2, "QUAD:LTUH:170:BMAX")
  field(DOL3, "QUAD:LTUH:170:BMAX")
  field(DOL4, "QUAD:LTUH:170:BMIN")
  field(DOL5, "QUAD:LTUH:170:BMIN")
  field(DOL6, "QUAD:LTUH:170:BMIN")
  field(LNK1, "QUAD:LTUH:170:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:170:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:170:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:170:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:170:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:170:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:170:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:170:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:170:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:170:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:170:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:170:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:130:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:170:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:130:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:170:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:170:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:130:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:170:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:170:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:170:EDES NPP MS")
  field(INPB, "QUAD:LTUH:170:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:350:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:350:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:350:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:350:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:350:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:350:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:350:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:350:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:350:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:350:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:350:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:350:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:350:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:350:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:350:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:350:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:350:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:350:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:350:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:350:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:350:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:350:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:350:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:350:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:350:BMAX")
  field(DOL2, "QUAD:LTUH:350:BMAX")
  field(DOL3, "QUAD:LTUH:350:BMAX")
  field(DOL4, "QUAD:LTUH:350:BMIN")
  field(DOL5, "QUAD:LTUH:350:BMIN")
  field(DOL6, "QUAD:LTUH:350:BMIN")
  field(LNK1, "QUAD:LTUH:350:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:350:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:350:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:350:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:350:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:350:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:350:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:350:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:350:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:350:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:350:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:350:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:250:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:350:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:250:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:350:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:350:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:250:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:350:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:350:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:350:EDES NPP MS")
  field(INPB, "QUAD:LTUH:350:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:450:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:450:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:450:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:450:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:450:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:450:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:450:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:450:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:450:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:450:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:450:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:450:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:450:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:450:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:450:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:450:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:450:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:450:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:450:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:450:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:450:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:450:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:450:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:450:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:450:BMAX")
  field(DOL2, "QUAD:LTUH:450:BMAX")
  field(DOL3, "QUAD:LTUH:450:BMAX")
  field(DOL4, "QUAD:LTUH:450:BMIN")
  field(DOL5, "QUAD:LTUH:450:BMIN")
  field(DOL6, "QUAD:LTUH:450:BMIN")
  field(LNK1, "QUAD:LTUH:450:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:450:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:450:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:450:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:450:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:450:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:450:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:450:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:450:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:450:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:450:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:450:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:250:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:450:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:250:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:450:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:450:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:250:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:450:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:450:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:450:EDES NPP MS")
  field(INPB, "QUAD:LTUH:450:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:550:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:550:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:550:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:550:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:550:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:550:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:550:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:550:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:550:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:550:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:550:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:550:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:550:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:550:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:550:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:550:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:550:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:550:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:550:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:550:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:550:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:550:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:550:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:550:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:550:BMAX")
  field(DOL2, "QUAD:LTUH:550:BMAX")
  field(DOL3, "QUAD:LTUH:550:BMAX")
  field(DOL4, "QUAD:LTUH:550:BMIN")
  field(DOL5, "QUAD:LTUH:550:BMIN")
  field(DOL6, "QUAD:LTUH:550:BMIN")
  field(LNK1, "QUAD:LTUH:550:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:550:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:550:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:550:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:550:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:550:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:550:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:550:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:550:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:550:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:550:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:550:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:250:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:550:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:250:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:550:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:550:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:250:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:550:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:550:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:550:EDES NPP MS")
  field(INPB, "QUAD:LTUH:550:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:295:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:295:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:295:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:295:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:295:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:295:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:295:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:295:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:295:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:295:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:295:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:295:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:295:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:295:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:295:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:295:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:295:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:295:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:295:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:295:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:295:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:295:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:295:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:295:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:295:BMAX")
  field(DOL2, "QUAD:LTUH:295:BMAX")
  field(DOL3, "QUAD:LTUH:295:BMAX")
  field(DOL4, "QUAD:LTUH:295:BMIN")
  field(DOL5, "QUAD:LTUH:295:BMIN")
  field(DOL6, "QUAD:LTUH:295:BMIN")
  field(LNK1, "QUAD:LTUH:295:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:295:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:295:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:295:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:295:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:295:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:295:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:295:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:295:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:295:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:295:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:295:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:285:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:295:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:285:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:295:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:295:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:285:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:295:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:295:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:295:EDES NPP MS")
  field(INPB, "QUAD:LTUH:295:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:385:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:385:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:385:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:385:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:385:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:385:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:385:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:385:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:385:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:385:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:385:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:385:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:385:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:385:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:385:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:385:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:385:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:385:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:385:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:385:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:385:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:385:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:385:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:385:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:385:BMAX")
  field(DOL2, "QUAD:LTUH:385:BMAX")
  field(DOL3, "QUAD:LTUH:385:BMAX")
  field(DOL4, "QUAD:LTUH:385:BMIN")
  field(DOL5, "QUAD:LTUH:385:BMIN")
  field(DOL6, "QUAD:LTUH:385:BMIN")
  field(LNK1, "QUAD:LTUH:385:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:385:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:385:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:385:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:385:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:385:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:385:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:385:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:385:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:385:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:385:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:385:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:285:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:385:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:285:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:385:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:385:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:285:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:385:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:385:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:385:EDES NPP MS")
  field(INPB, "QUAD:LTUH:385:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:395:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:395:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:395:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:395:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:395:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:395:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:395:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:395:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:395:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:395:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:395:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:395:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:395:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:395:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:395:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:395:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:395:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:395:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:395:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:395:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:395:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:395:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:395:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:395:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:395:BMAX")
  field(DOL2, "QUAD:LTUH:395:BMAX")
  field(DOL3, "QUAD:LTUH:395:BMAX")
  field(DOL4, "QUAD:LTUH:395:BMIN")
  field(DOL5, "QUAD:LTUH:395:BMIN")
  field(DOL6, "QUAD:LTUH:395:BMIN")
  field(LNK1, "QUAD:LTUH:395:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:395:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:395:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:395:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:395:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:395:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:395:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:395:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:395:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:395:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:395:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:395:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:285:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:395:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:285:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:395:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:395:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:285:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:395:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:395:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:395:EDES NPP MS")
  field(INPB, "QUAD:LTUH:395:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:485:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:485:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:485:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:485:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:485:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:485:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:485:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:485:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:485:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:485:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:485:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:485:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:485:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:485:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:485:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:485:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:485:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:485:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:485:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:485:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:485:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:485:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:485:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:485:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:485:BMAX")
  field(DOL2, "QUAD:LTUH:485:BMAX")
  field(DOL3, "QUAD:LTUH:485:BMAX")
  field(DOL4, "QUAD:LTUH:485:BMIN")
  field(DOL5, "QUAD:LTUH:485:BMIN")
  field(DOL6, "QUAD:LTUH:485:BMIN")
  field(LNK1, "QUAD:LTUH:485:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:485:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:485:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:485:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:485:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:485:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:485:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:485:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:485:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:485:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:485:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:485:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:285:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:485:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:285:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:485:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:485:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:285:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:485:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:485:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:485:EDES NPP MS")
  field(INPB, "QUAD:LTUH:485:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:495:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:495:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:495:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:495:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:495:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:495:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:495:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:495:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:495:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:495:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:495:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:495:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:495:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:495:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:495:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:495:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:495:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:495:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:495:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:495:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:495:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:495:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:495:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:495:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:495:BMAX")
  field(DOL2, "QUAD:LTUH:495:BMAX")
  field(DOL3, "QUAD:LTUH:495:BMAX")
  field(DOL4, "QUAD:LTUH:495:BMIN")
  field(DOL5, "QUAD:LTUH:495:BMIN")
  field(DOL6, "QUAD:LTUH:495:BMIN")
  field(LNK1, "QUAD:LTUH:495:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:495:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:495:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:495:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:495:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:495:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:495:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:495:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:495:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:495:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:495:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:495:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:285:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:495:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:285:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:495:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:495:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:285:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:495:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:495:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:495:EDES NPP MS")
  field(INPB, "QUAD:LTUH:495:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:585:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:585:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:585:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:585:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:585:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:585:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:585:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:585:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:585:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:585:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:585:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:585:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:585:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:585:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:585:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:585:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:585:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:585:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:585:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:585:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:585:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:585:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:585:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:585:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:585:BMAX")
  field(DOL2, "QUAD:LTUH:585:BMAX")
  field(DOL3, "QUAD:LTUH:585:BMAX")
  field(DOL4, "QUAD:LTUH:585:BMIN")
  field(DOL5, "QUAD:LTUH:585:BMIN")
  field(DOL6, "QUAD:LTUH:585:BMIN")
  field(LNK1, "QUAD:LTUH:585:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:585:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:585:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:585:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:585:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:585:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:585:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:585:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:585:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:585:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:585:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:585:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:285:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:585:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:285:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:585:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:585:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:285:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:585:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:585:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:585:EDES NPP MS")
  field(INPB, "QUAD:LTUH:585:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:595:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:595:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:595:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:595:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:595:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:595:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:595:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:595:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:595:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:595:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:595:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:595:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:595:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:595:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:595:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:595:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:595:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:595:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:595:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:595:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:595:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:595:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:595:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:595:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:595:BMAX")
  field(DOL2, "QUAD:LTUH:595:BMAX")
  field(DOL3, "QUAD:LTUH:595:BMAX")
  field(DOL4, "QUAD:LTUH:595:BMIN")
  field(DOL5, "QUAD:LTUH:595:BMIN")
  field(DOL6, "QUAD:LTUH:595:BMIN")
  field(LNK1, "QUAD:LTUH:595:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:595:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:595:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:595:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:595:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:595:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:595:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:595:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:595:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:595:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:595:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:595:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:285:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:595:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:285:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:595:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:595:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:285:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:595:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:595:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:595:EDES NPP MS")
  field(INPB, "QUAD:LTUH:595:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:390:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:390:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:390:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:390:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:390:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:390:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:390:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:390:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:390:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:390:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:390:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:390:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:390:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:390:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:390:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:390:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:390:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:390:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:390:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:390:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:390:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:390:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:390:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:390:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:390:BMAX")
  field(DOL2, "QUAD:LTUH:390:BMAX")
  field(DOL3, "QUAD:LTUH:390:BMAX")
  field(DOL4, "QUAD:LTUH:390:BMIN")
  field(DOL5, "QUAD:LTUH:390:BMIN")
  field(DOL6, "QUAD:LTUH:390:BMIN")
  field(LNK1, "QUAD:LTUH:390:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:390:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:390:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:390:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:390:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:390:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:390:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:390:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:390:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:390:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:390:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:390:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:290:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:390:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:290:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:390:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:390:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:290:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:390:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:390:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:390:EDES NPP MS")
  field(INPB, "QUAD:LTUH:390:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:490:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:490:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:490:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:490:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:490:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:490:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:490:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:490:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:490:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:490:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:490:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:490:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:490:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:490:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:490:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:490:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:490:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:490:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:490:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:490:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:490:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:490:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:490:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:490:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:490:BMAX")
  field(DOL2, "QUAD:LTUH:490:BMAX")
  field(DOL3, "QUAD:LTUH:490:BMAX")
  field(DOL4, "QUAD:LTUH:490:BMIN")
  field(DOL5, "QUAD:LTUH:490:BMIN")
  field(DOL6, "QUAD:LTUH:490:BMIN")
  field(LNK1, "QUAD:LTUH:490:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:490:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:490:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:490:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:490:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:490:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:490:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:490:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:490:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:490:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:490:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:490:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:290:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:490:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:290:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:490:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:490:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:290:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:490:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:490:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:490:EDES NPP MS")
  field(INPB, "QUAD:LTUH:490:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:590:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:590:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:590:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:590:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:590:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:590:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:590:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:590:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:590:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:590:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:590:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:590:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:590:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:590:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:590:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:590:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:590:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:590:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:590:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:590:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:590:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:590:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:590:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:590:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:590:BMAX")
  field(DOL2, "QUAD:LTUH:590:BMAX")
  field(DOL3, "QUAD:LTUH:590:BMAX")
  field(DOL4, "QUAD:LTUH:590:BMIN")
  field(DOL5, "QUAD:LTUH:590:BMIN")
  field(DOL6, "QUAD:LTUH:590:BMIN")
  field(LNK1, "QUAD:LTUH:590:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:590:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:590:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:590:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:590:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:590:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:590:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:590:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:590:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:590:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:590:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:590:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:290:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:590:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:290:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:590:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:590:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:290:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:590:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:590:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:590:EDES NPP MS")
  field(INPB, "QUAD:LTUH:590:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:730:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:730:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:730:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:730:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:730:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:730:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:730:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:730:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:730:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:730:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:730:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:730:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:730:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:730:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:730:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:730:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:730:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:730:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:730:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:730:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:730:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:730:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:730:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:730:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:730:BMAX")
  field(DOL2, "QUAD:LTUH:730:BMAX")
  field(DOL3, "QUAD:LTUH:730:BMAX")
  field(DOL4, "QUAD:LTUH:730:BMIN")
  field(DOL5, "QUAD:LTUH:730:BMIN")
  field(DOL6, "QUAD:LTUH:730:BMIN")
  field(LNK1, "QUAD:LTUH:730:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:730:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:730:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:730:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:730:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:730:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:730:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:730:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:730:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:730:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:730:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:730:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:720:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:730:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:720:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:730:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:730:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:720:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:730:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:730:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:730:EDES NPP MS")
  field(INPB, "QUAD:LTUH:730:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:740:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:740:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:740:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:740:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:740:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:740:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:740:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:740:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:740:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:740:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:740:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:740:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:740:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:740:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:740:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:740:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:740:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:740:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:740:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:740:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:740:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:740:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:740:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:740:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:740:BMAX")
  field(DOL2, "QUAD:LTUH:740:BMAX")
  field(DOL3, "QUAD:LTUH:740:BMAX")
  field(DOL4, "QUAD:LTUH:740:BMIN")
  field(DOL5, "QUAD:LTUH:740:BMIN")
  field(DOL6, "QUAD:LTUH:740:BMIN")
  field(LNK1, "QUAD:LTUH:740:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:740:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:740:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:740:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:740:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:740:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:740:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:740:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:740:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:740:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:740:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:740:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:720:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:740:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:720:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:740:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:740:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:720:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:740:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:740:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:740:EDES NPP MS")
  field(INPB, "QUAD:LTUH:740:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:750:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:750:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:750:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:750:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:750:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:750:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:750:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:750:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:750:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:750:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:750:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:750:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:750:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:750:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:750:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:750:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:750:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:750:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:750:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:750:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:750:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:750:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:750:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:750:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:750:BMAX")
  field(DOL2, "QUAD:LTUH:750:BMAX")
  field(DOL3, "QUAD:LTUH:750:BMAX")
  field(DOL4, "QUAD:LTUH:750:BMIN")
  field(DOL5, "QUAD:LTUH:750:BMIN")
  field(DOL6, "QUAD:LTUH:750:BMIN")
  field(LNK1, "QUAD:LTUH:750:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:750:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:750:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:750:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:750:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:750:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:750:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:750:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:750:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:750:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:750:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:750:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:720:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:750:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:720:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:750:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:750:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:720:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:750:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:750:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:750:EDES NPP MS")
  field(INPB, "QUAD:LTUH:750:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:760:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:760:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:760:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:760:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:760:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:760:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:760:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:760:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:760:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:760:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:760:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:760:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:760:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:760:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:760:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:760:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:760:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:760:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:760:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:760:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:760:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:760:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:760:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:760:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:760:BMAX")
  field(DOL2, "QUAD:LTUH:760:BMAX")
  field(DOL3, "QUAD:LTUH:760:BMAX")
  field(DOL4, "QUAD:LTUH:760:BMIN")
  field(DOL5, "QUAD:LTUH:760:BMIN")
  field(DOL6, "QUAD:LTUH:760:BMIN")
  field(LNK1, "QUAD:LTUH:760:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:760:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:760:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:760:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:760:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:760:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:760:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:760:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:760:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:760:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:760:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:760:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:720:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:760:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:720:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:760:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:760:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:720:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:760:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:760:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:760:EDES NPP MS")
  field(INPB, "QUAD:LTUH:760:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUH:770:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUH:770:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUH:770:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUH:770:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUH:770:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUH:770:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUH:770:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUH:770:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUH:770:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUH:770:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUH:770:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUH:770:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUH:770:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUH:770:EDES.PROC PP")
    field(LNK2, "QUAD:LTUH:770:EACT.PROC PP")
    field(LNK3, "QUAD:LTUH:770:EERR.DISA PP")
    field(LNK4, "QUAD:LTUH:770:ECON.PROC PP")
    field(LNK5, "QUAD:LTUH:770:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUH:770:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUH:770:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUH:770:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUH:770:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUH:770:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUH:770:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUH:770:BMAX")
  field(DOL2, "QUAD:LTUH:770:BMAX")
  field(DOL3, "QUAD:LTUH:770:BMAX")
  field(DOL4, "QUAD:LTUH:770:BMIN")
  field(DOL5, "QUAD:LTUH:770:BMIN")
  field(DOL6, "QUAD:LTUH:770:BMIN")
  field(LNK1, "QUAD:LTUH:770:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUH:770:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUH:770:BLEM.HOPR")
  field(LNK4, "QUAD:LTUH:770:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUH:770:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUH:770:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:770:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUH:770:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUH:770:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUH:770:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUH:770:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:770:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUH:720:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:770:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:720:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:770:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUH:770:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUH:720:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUH:770:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUH:770:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUH:770:EDES NPP MS")
  field(INPB, "QUAD:LTUH:770:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:LTUS:360:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "KICK:LTUS:360:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:LTUS:360:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:LTUS:360:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:LTUS:360:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:LTUS:360:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:LTUS:360:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:LTUS:360:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:LTUS:360:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:LTUS:360:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:LTUS:360:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:LTUS:360:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:LTUS:360:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:LTUS:360:EDES.PROC PP")
    field(LNK2, "KICK:LTUS:360:EACT.PROC PP")
    field(LNK3, "KICK:LTUS:360:EERR.DISA PP")
    field(LNK4, "KICK:LTUS:360:ECON.PROC PP")
    field(LNK5, "KICK:LTUS:360:BMAGX.PROC PP")
    field(LNK6, "KICK:LTUS:360:BMAGY.PROC PP")
    field(LNK7, "KICK:LTUS:360:BLEM.PROC PP")
    field(LNK8, "KICK:LTUS:360:BMOD.PROC PP")
    field(LNK9, "KICK:LTUS:360:EDESSAVE.PROC PP")
    field(LNKA, "KICK:LTUS:360:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:LTUS:360:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:LTUS:360:BMAX")
  field(DOL2, "KICK:LTUS:360:BMAX")
  field(DOL3, "KICK:LTUS:360:BMAX")
  field(DOL4, "KICK:LTUS:360:BMIN")
  field(DOL5, "KICK:LTUS:360:BMIN")
  field(DOL6, "KICK:LTUS:360:BMIN")
  field(LNK1, "KICK:LTUS:360:BMAGX.HOPR")
  field(LNK2, "KICK:LTUS:360:BMAGY.HOPR")
  field(LNK3, "KICK:LTUS:360:BLEM.HOPR")
  field(LNK4, "KICK:LTUS:360:BMAGX.LOPR PP")
  field(LNK5, "KICK:LTUS:360:BMAGY.LOPR PP")
  field(LNK6, "KICK:LTUS:360:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:LTUS:360:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:LTUS:360:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:LTUS:360:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:LTUS:360:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:LTUS:360:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LTUS:360:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "KICK:LTUS:350:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LTUS:360:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "KICK:LTUS:350:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:LTUS:360:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:LTUS:360:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "KICK:LTUS:350:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:LTUS:360:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:LTUS:360:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:LTUS:360:EDES NPP MS")
  field(INPB, "KICK:LTUS:360:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:165:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:165:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:165:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:165:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:165:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:165:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:165:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:165:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:165:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:165:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:165:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:165:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:165:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:165:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:165:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:165:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:165:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:165:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:165:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:165:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:165:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:165:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:165:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:165:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:165:BMAX")
  field(DOL2, "BEND:LTUS:165:BMAX")
  field(DOL3, "BEND:LTUS:165:BMAX")
  field(DOL4, "BEND:LTUS:165:BMIN")
  field(DOL5, "BEND:LTUS:165:BMIN")
  field(DOL6, "BEND:LTUS:165:BMIN")
  field(LNK1, "BEND:LTUS:165:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:165:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:165:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:165:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:165:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:165:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:165:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:165:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:165:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:165:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:165:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:165:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUS:166:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:165:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:166:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:165:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:165:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:166:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:165:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:165:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:165:EDES NPP MS")
  field(INPB, "BEND:LTUS:165:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:167:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:167:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:167:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:167:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:167:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:167:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:167:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:167:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:167:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:167:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:167:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:167:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:167:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:167:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:167:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:167:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:167:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:167:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:167:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:167:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:167:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:167:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:167:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:167:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:167:BMAX")
  field(DOL2, "BEND:LTUS:167:BMAX")
  field(DOL3, "BEND:LTUS:167:BMAX")
  field(DOL4, "BEND:LTUS:167:BMIN")
  field(DOL5, "BEND:LTUS:167:BMIN")
  field(DOL6, "BEND:LTUS:167:BMIN")
  field(LNK1, "BEND:LTUS:167:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:167:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:167:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:167:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:167:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:167:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:167:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:167:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:167:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:167:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:167:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:167:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUS:166:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:167:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:166:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:167:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:167:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:166:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:167:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:167:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:167:EDES NPP MS")
  field(INPB, "BEND:LTUS:167:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:168:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:168:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:168:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:168:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:168:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:168:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:168:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:168:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:168:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:168:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:168:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:168:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:168:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:168:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:168:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:168:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:168:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:168:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:168:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:168:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:168:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:168:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:168:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:168:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:168:BMAX")
  field(DOL2, "BEND:LTUS:168:BMAX")
  field(DOL3, "BEND:LTUS:168:BMAX")
  field(DOL4, "BEND:LTUS:168:BMIN")
  field(DOL5, "BEND:LTUS:168:BMIN")
  field(DOL6, "BEND:LTUS:168:BMIN")
  field(LNK1, "BEND:LTUS:168:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:168:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:168:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:168:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:168:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:168:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:168:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:168:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:168:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:168:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:168:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:168:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUS:166:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:168:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:166:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:168:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:168:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:166:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:168:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:168:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:168:EDES NPP MS")
  field(INPB, "BEND:LTUS:168:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:475:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:475:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:475:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:475:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:475:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:475:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:475:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:475:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:475:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:475:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:475:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:475:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:475:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:475:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:475:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:475:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:475:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:475:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:475:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:475:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:475:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:475:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:475:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:475:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:475:BMAX")
  field(DOL2, "BEND:LTUS:475:BMAX")
  field(DOL3, "BEND:LTUS:475:BMAX")
  field(DOL4, "BEND:LTUS:475:BMIN")
  field(DOL5, "BEND:LTUS:475:BMIN")
  field(DOL6, "BEND:LTUS:475:BMIN")
  field(LNK1, "BEND:LTUS:475:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:475:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:475:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:475:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:475:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:475:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:475:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:475:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:475:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:475:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:475:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:475:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUS:476:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:475:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:476:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:475:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:475:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:476:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:475:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:475:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:475:EDES NPP MS")
  field(INPB, "BEND:LTUS:475:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:477:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:477:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:477:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:477:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:477:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:477:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:477:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:477:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:477:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:477:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:477:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:477:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:477:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:477:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:477:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:477:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:477:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:477:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:477:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:477:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:477:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:477:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:477:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:477:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:477:BMAX")
  field(DOL2, "BEND:LTUS:477:BMAX")
  field(DOL3, "BEND:LTUS:477:BMAX")
  field(DOL4, "BEND:LTUS:477:BMIN")
  field(DOL5, "BEND:LTUS:477:BMIN")
  field(DOL6, "BEND:LTUS:477:BMIN")
  field(LNK1, "BEND:LTUS:477:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:477:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:477:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:477:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:477:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:477:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:477:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:477:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:477:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:477:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:477:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:477:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUS:476:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:477:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:476:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:477:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:477:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:476:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:477:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:477:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:477:EDES NPP MS")
  field(INPB, "BEND:LTUS:477:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:478:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:478:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:478:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:478:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:478:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:478:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:478:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:478:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:478:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:478:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:478:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:478:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:478:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:478:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:478:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:478:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:478:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:478:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:478:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:478:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:478:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:478:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:478:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:478:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:478:BMAX")
  field(DOL2, "BEND:LTUS:478:BMAX")
  field(DOL3, "BEND:LTUS:478:BMAX")
  field(DOL4, "BEND:LTUS:478:BMIN")
  field(DOL5, "BEND:LTUS:478:BMIN")
  field(DOL6, "BEND:LTUS:478:BMIN")
  field(LNK1, "BEND:LTUS:478:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:478:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:478:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:478:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:478:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:478:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:478:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:478:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:478:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:478:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:478:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:478:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUS:476:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:478:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:476:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:478:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:478:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:476:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:478:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:478:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:478:EDES NPP MS")
  field(INPB, "BEND:LTUS:478:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:565:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:565:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:565:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:565:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:565:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:565:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:565:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:565:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:565:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:565:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:565:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:565:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:565:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:565:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:565:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:565:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:565:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:565:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:565:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:565:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:565:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:565:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:565:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:565:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:565:BMAX")
  field(DOL2, "BEND:LTUS:565:BMAX")
  field(DOL3, "BEND:LTUS:565:BMAX")
  field(DOL4, "BEND:LTUS:565:BMIN")
  field(DOL5, "BEND:LTUS:565:BMIN")
  field(DOL6, "BEND:LTUS:565:BMIN")
  field(LNK1, "BEND:LTUS:565:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:565:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:565:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:565:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:565:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:565:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:565:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:565:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:565:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:565:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:565:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:565:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUS:525:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:565:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:525:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:565:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:565:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:525:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:565:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:565:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:565:EDES NPP MS")
  field(INPB, "BEND:LTUS:565:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:763:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:763:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:763:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:763:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:763:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:763:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:763:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:763:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:763:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:763:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:763:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:763:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:763:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:763:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:763:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:763:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:763:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:763:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:763:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:763:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:763:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:763:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:763:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:763:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:763:BMAX")
  field(DOL2, "BEND:LTUS:763:BMAX")
  field(DOL3, "BEND:LTUS:763:BMAX")
  field(DOL4, "BEND:LTUS:763:BMIN")
  field(DOL5, "BEND:LTUS:763:BMIN")
  field(DOL6, "BEND:LTUS:763:BMIN")
  field(LNK1, "BEND:LTUS:763:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:763:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:763:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:763:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:763:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:763:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:763:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:763:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:763:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:763:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:763:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:763:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUS:764:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:763:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:764:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:763:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:763:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:764:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:763:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:763:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:763:EDES NPP MS")
  field(INPB, "BEND:LTUS:763:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:765:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:765:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:765:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:765:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:765:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:765:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:765:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:765:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:765:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:765:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:765:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:765:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:765:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:765:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:765:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:765:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:765:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:765:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:765:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:765:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:765:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:765:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:765:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:765:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:765:BMAX")
  field(DOL2, "BEND:LTUS:765:BMAX")
  field(DOL3, "BEND:LTUS:765:BMAX")
  field(DOL4, "BEND:LTUS:765:BMIN")
  field(DOL5, "BEND:LTUS:765:BMIN")
  field(DOL6, "BEND:LTUS:765:BMIN")
  field(LNK1, "BEND:LTUS:765:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:765:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:765:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:765:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:765:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:765:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:765:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:765:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:765:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:765:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:765:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:765:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUS:764:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:765:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:764:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:765:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:765:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:764:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:765:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:765:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:765:EDES NPP MS")
  field(INPB, "BEND:LTUS:765:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:766:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:766:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:766:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:766:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:766:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:766:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:766:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:766:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:766:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:766:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:766:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:766:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:766:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:766:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:766:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:766:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:766:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:766:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:766:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:766:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:766:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:766:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:766:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:766:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:766:BMAX")
  field(DOL2, "BEND:LTUS:766:BMAX")
  field(DOL3, "BEND:LTUS:766:BMAX")
  field(DOL4, "BEND:LTUS:766:BMIN")
  field(DOL5, "BEND:LTUS:766:BMIN")
  field(DOL6, "BEND:LTUS:766:BMIN")
  field(LNK1, "BEND:LTUS:766:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:766:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:766:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:766:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:766:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:766:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:766:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:766:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:766:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:766:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:766:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:766:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:LTUS:764:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:766:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:764:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:766:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:766:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:LTUS:764:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:766:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:766:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:766:EDES NPP MS")
  field(INPB, "BEND:LTUS:766:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:270:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:270:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:270:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:270:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:270:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:270:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:270:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:270:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:270:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:270:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:270:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:270:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:270:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:270:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:270:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:270:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:270:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:270:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:270:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:270:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:270:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:270:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:270:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:270:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:270:BMAX")
  field(DOL2, "QUAD:LTUS:270:BMAX")
  field(DOL3, "QUAD:LTUS:270:BMAX")
  field(DOL4, "QUAD:LTUS:270:BMIN")
  field(DOL5, "QUAD:LTUS:270:BMIN")
  field(DOL6, "QUAD:LTUS:270:BMIN")
  field(LNK1, "QUAD:LTUS:270:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:270:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:270:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:270:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:270:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:270:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:270:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:270:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:270:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:270:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:270:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:270:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUS:235:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:270:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:235:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:270:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:270:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:235:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:270:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:270:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:270:EDES NPP MS")
  field(INPB, "QUAD:LTUS:270:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:300:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:300:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:300:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:300:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:300:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:300:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:300:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:300:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:300:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:300:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:300:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:300:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:300:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:300:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:300:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:300:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:300:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:300:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:300:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:300:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:300:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:300:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:300:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:300:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:300:BMAX")
  field(DOL2, "QUAD:LTUS:300:BMAX")
  field(DOL3, "QUAD:LTUS:300:BMAX")
  field(DOL4, "QUAD:LTUS:300:BMIN")
  field(DOL5, "QUAD:LTUS:300:BMIN")
  field(DOL6, "QUAD:LTUS:300:BMIN")
  field(LNK1, "QUAD:LTUS:300:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:300:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:300:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:300:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:300:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:300:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:300:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:300:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:300:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:300:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:300:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:300:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUS:180:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:300:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:180:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:300:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:300:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:180:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:300:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:300:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:300:EDES NPP MS")
  field(INPB, "QUAD:LTUS:300:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:345:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:345:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:345:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:345:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:345:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:345:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:345:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:345:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:345:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:345:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:345:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:345:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:345:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:345:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:345:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:345:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:345:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:345:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:345:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:345:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:345:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:345:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:345:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:345:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:345:BMAX")
  field(DOL2, "QUAD:LTUS:345:BMAX")
  field(DOL3, "QUAD:LTUS:345:BMAX")
  field(DOL4, "QUAD:LTUS:345:BMIN")
  field(DOL5, "QUAD:LTUS:345:BMIN")
  field(DOL6, "QUAD:LTUS:345:BMIN")
  field(LNK1, "QUAD:LTUS:345:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:345:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:345:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:345:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:345:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:345:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:345:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:345:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:345:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:345:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:345:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:345:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUS:180:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:345:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:180:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:345:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:345:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:180:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:345:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:345:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:345:EDES NPP MS")
  field(INPB, "QUAD:LTUS:345:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:370:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:370:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:370:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:370:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:370:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:370:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:370:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:370:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:370:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:370:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:370:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:370:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:370:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:370:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:370:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:370:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:370:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:370:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:370:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:370:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:370:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:370:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:370:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:370:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:370:BMAX")
  field(DOL2, "QUAD:LTUS:370:BMAX")
  field(DOL3, "QUAD:LTUS:370:BMAX")
  field(DOL4, "QUAD:LTUS:370:BMIN")
  field(DOL5, "QUAD:LTUS:370:BMIN")
  field(DOL6, "QUAD:LTUS:370:BMIN")
  field(LNK1, "QUAD:LTUS:370:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:370:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:370:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:370:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:370:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:370:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:370:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:370:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:370:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:370:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:370:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:370:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUS:235:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:370:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:235:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:370:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:370:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:235:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:370:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:370:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:370:EDES NPP MS")
  field(INPB, "QUAD:LTUS:370:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:430:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:430:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:430:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:430:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:430:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:430:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:430:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:430:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:430:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:430:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:430:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:430:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:430:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:430:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:430:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:430:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:430:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:430:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:430:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:430:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:430:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:430:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:430:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:430:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:430:BMAX")
  field(DOL2, "QUAD:LTUS:430:BMAX")
  field(DOL3, "QUAD:LTUS:430:BMAX")
  field(DOL4, "QUAD:LTUS:430:BMIN")
  field(DOL5, "QUAD:LTUS:430:BMIN")
  field(DOL6, "QUAD:LTUS:430:BMIN")
  field(LNK1, "QUAD:LTUS:430:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:430:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:430:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:430:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:430:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:430:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:430:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:430:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:430:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:430:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:430:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:430:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUS:235:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:430:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:235:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:430:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:430:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:235:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:430:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:430:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:430:EDES NPP MS")
  field(INPB, "QUAD:LTUS:430:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:450:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:450:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:450:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:450:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:450:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:450:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:450:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:450:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:450:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:450:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:450:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:450:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:450:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:450:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:450:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:450:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:450:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:450:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:450:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:450:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:450:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:450:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:450:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:450:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:450:BMAX")
  field(DOL2, "QUAD:LTUS:450:BMAX")
  field(DOL3, "QUAD:LTUS:450:BMAX")
  field(DOL4, "QUAD:LTUS:450:BMIN")
  field(DOL5, "QUAD:LTUS:450:BMIN")
  field(DOL6, "QUAD:LTUS:450:BMIN")
  field(LNK1, "QUAD:LTUS:450:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:450:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:450:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:450:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:450:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:450:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:450:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:450:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:450:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:450:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:450:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:450:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUS:180:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:450:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:180:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:450:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:450:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:180:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:450:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:450:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:450:EDES NPP MS")
  field(INPB, "QUAD:LTUS:450:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:550:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:550:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:550:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:550:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:550:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:550:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:550:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:550:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:550:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:550:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:550:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:550:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:550:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:550:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:550:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:550:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:550:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:550:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:550:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:550:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:550:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:550:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:550:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:550:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:550:BMAX")
  field(DOL2, "QUAD:LTUS:550:BMAX")
  field(DOL3, "QUAD:LTUS:550:BMAX")
  field(DOL4, "QUAD:LTUS:550:BMIN")
  field(DOL5, "QUAD:LTUS:550:BMIN")
  field(DOL6, "QUAD:LTUS:550:BMIN")
  field(LNK1, "QUAD:LTUS:550:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:550:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:550:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:550:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:550:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:550:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:550:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:550:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:550:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:550:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:550:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:550:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUS:540:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:550:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:540:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:550:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:550:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:540:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:550:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:550:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:550:EDES NPP MS")
  field(INPB, "QUAD:LTUS:550:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:LTUS:560:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "QUAD:LTUS:560:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:LTUS:560:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:LTUS:560:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:LTUS:560:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:LTUS:560:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:LTUS:560:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:LTUS:560:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:LTUS:560:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:LTUS:560:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:LTUS:560:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:LTUS:560:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:LTUS:560:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:LTUS:560:EDES.PROC PP")
    field(LNK2, "QUAD:LTUS:560:EACT.PROC PP")
    field(LNK3, "QUAD:LTUS:560:EERR.DISA PP")
    field(LNK4, "QUAD:LTUS:560:ECON.PROC PP")
    field(LNK5, "QUAD:LTUS:560:BMAGX.PROC PP")
    field(LNK6, "QUAD:LTUS:560:BMAGY.PROC PP")
    field(LNK7, "QUAD:LTUS:560:BLEM.PROC PP")
    field(LNK8, "QUAD:LTUS:560:BMOD.PROC PP")
    field(LNK9, "QUAD:LTUS:560:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:LTUS:560:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:LTUS:560:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:LTUS:560:BMAX")
  field(DOL2, "QUAD:LTUS:560:BMAX")
  field(DOL3, "QUAD:LTUS:560:BMAX")
  field(DOL4, "QUAD:LTUS:560:BMIN")
  field(DOL5, "QUAD:LTUS:560:BMIN")
  field(DOL6, "QUAD:LTUS:560:BMIN")
  field(LNK1, "QUAD:LTUS:560:BMAGX.HOPR")
  field(LNK2, "QUAD:LTUS:560:BMAGY.HOPR")
  field(LNK3, "QUAD:LTUS:560:BLEM.HOPR")
  field(LNK4, "QUAD:LTUS:560:BMAGX.LOPR PP")
  field(LNK5, "QUAD:LTUS:560:BMAGY.LOPR PP")
  field(LNK6, "QUAD:LTUS:560:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:560:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:LTUS:560:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:LTUS:560:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:LTUS:560:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:LTUS:560:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:560:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:LTUS:540:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:560:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:540:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:560:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:LTUS:560:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:LTUS:540:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:LTUS:560:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:LTUS:560:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:LTUS:560:EDES NPP MS")
  field(INPB, "QUAD:LTUS:560:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:UNDH:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:UNDH:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:UNDH:1:CTRL CA PP")
  field(LNK2, "MGNT:UNDH:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:UNDH:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:UNDH:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:UNDH:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:UNDH:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:UNDH:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:UNDH:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:UNDH:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:UNDH:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:UNDH:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:UNDH:1:ALLSWITCH")
}

record(seq, "MGNT:UNDH:1:ALLSWITCH") {
  field(DOL1, "MGNT:UNDH:1:CTRL.FFVL")
  field(LNK1, "MGNT:UNDH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDH:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDH:1:CTRL")
}

record(bo, "MGNT:UNDH:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:UNDH:1:ALLSTARGO")
}

record(fanout, "MGNT:UNDH:1:ALLSTARGO") {
  field(LNK1, "MGNT:UNDH:1:ALLBENDSGO")
  field(LNK2, "MGNT:UNDH:1:ALLBTRMSGO")
  field(LNK3, "MGNT:UNDH:1:ALLLGPSSGO")
  field(LNK4, "MGNT:UNDH:1:ALLQUADSGO")
  field(LNK5, "MGNT:UNDH:1:ALLXCORSGO")
  field(LNK6, "MGNT:UNDH:1:ALLYCORSGO")
  field(FLNK, "MGNT:UNDH:1:ALLSTARGO_2")
}
record(fanout, "MGNT:UNDH:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:UNDH:1:ALLSOLNSGO")
  field(LNK2, "MGNT:UNDH:1:ALLKICKSGO")
  field(LNK3, "MGNT:UNDH:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:UNDH:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:UNDH:1:BENDSWITCH")
}

record(seq, "MGNT:UNDH:1:BENDSWITCH") {
  field(DOL1, "MGNT:UNDH:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:UNDH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDH:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDH:1:BENDCTRL")
}

record(seq, "MGNT:UNDH:1:ALLBENDSGO") {
  field(DOL1, "MGNT:UNDH:1:ALLSTAR")
  field(LNK1, "MGNT:UNDH:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:UNDH:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDH:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDH:1:BENDCTRL",20,10,0,0,"MGNT:UNDH:1:BENDCTRL")
#! Field("MGNT:UNDH:1:BENDCTRL.FLNK",16777215,1,"MGNT:UNDH:1:BENDCTRL.FLNK")
#! Link("MGNT:UNDH:1:BENDCTRL.FLNK","MGNT:UNDH:1:BENDSWITCH")
#! Field("MGNT:UNDH:1:BENDCTRL.FFVL",16777215,1,"MGNT:UNDH:1:BENDCTRL.FFVL")
#! Record("MGNT:UNDH:1:BENDSWITCH",460,322,0,0,"MGNT:UNDH:1:BENDSWITCH")
#! Field("MGNT:UNDH:1:BENDSWITCH.DOL1",16777215,0,"MGNT:UNDH:1:BENDSWITCH.DOL1")
#! Link("MGNT:UNDH:1:BENDSWITCH.DOL1","MGNT:UNDH:1:BENDCTRL.FFVL")
#! Field("MGNT:UNDH:1:BENDSWITCH.LNK1",16777215,1,"MGNT:UNDH:1:BENDSWITCH.LNK1")
#! Field("MGNT:UNDH:1:BENDSWITCH.FLNK",16777215,1,"MGNT:UNDH:1:BENDSWITCH.FLNK")
#! Record("MGNT:UNDH:1:ALLBENDSGO",240,96,0,0,"MGNT:UNDH:1:ALLBENDSGO")
#! Field("MGNT:UNDH:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:UNDH:1:ALLBENDSGO.DOL1")
#! Field("MGNT:UNDH:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:UNDH:1:ALLBENDSGO.LNK1")
#! Link("MGNT:UNDH:1:ALLBENDSGO.LNK1","MGNT:UNDH:1:ALLBENDS.VAL")
#! Record("MGNT:UNDH:1:ALLBENDS",540,102,0,0,"MGNT:UNDH:1:ALLBENDS")
#! Field("MGNT:UNDH:1:ALLBENDS.VAL",16777215,0,"MGNT:UNDH:1:ALLBENDS.VAL")
#! Field("MGNT:UNDH:1:ALLBENDS.FLNK",16777215,1,"MGNT:UNDH:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:UNDH:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:UNDH:1:BTRMSWITCH")
}

record(seq, "MGNT:UNDH:1:BTRMSWITCH") {
  field(DOL1, "MGNT:UNDH:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:UNDH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDH:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDH:1:BTRMCTRL")
}

record(seq, "MGNT:UNDH:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:UNDH:1:ALLSTAR")
  field(LNK1, "MGNT:UNDH:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:UNDH:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDH:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDH:1:BTRMCTRL",20,10,0,0,"MGNT:UNDH:1:BTRMCTRL")
#! Field("MGNT:UNDH:1:BTRMCTRL.FLNK",16777215,1,"MGNT:UNDH:1:BTRMCTRL.FLNK")
#! Link("MGNT:UNDH:1:BTRMCTRL.FLNK","MGNT:UNDH:1:BTRMSWITCH")
#! Field("MGNT:UNDH:1:BTRMCTRL.FFVL",16777215,1,"MGNT:UNDH:1:BTRMCTRL.FFVL")
#! Record("MGNT:UNDH:1:BTRMSWITCH",460,322,0,0,"MGNT:UNDH:1:BTRMSWITCH")
#! Field("MGNT:UNDH:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:UNDH:1:BTRMSWITCH.DOL1")
#! Link("MGNT:UNDH:1:BTRMSWITCH.DOL1","MGNT:UNDH:1:BTRMCTRL.FFVL")
#! Field("MGNT:UNDH:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:UNDH:1:BTRMSWITCH.LNK1")
#! Field("MGNT:UNDH:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:UNDH:1:BTRMSWITCH.FLNK")
#! Record("MGNT:UNDH:1:ALLBTRMSGO",240,96,0,0,"MGNT:UNDH:1:ALLBTRMSGO")
#! Field("MGNT:UNDH:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:UNDH:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:UNDH:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:UNDH:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:UNDH:1:ALLBTRMSGO.LNK1","MGNT:UNDH:1:ALLBTRMS.VAL")
#! Record("MGNT:UNDH:1:ALLBTRMS",540,102,0,0,"MGNT:UNDH:1:ALLBTRMS")
#! Field("MGNT:UNDH:1:ALLBTRMS.VAL",16777215,0,"MGNT:UNDH:1:ALLBTRMS.VAL")
#! Field("MGNT:UNDH:1:ALLBTRMS.FLNK",16777215,1,"MGNT:UNDH:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:UNDH:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:UNDH:1:LGPSSWITCH")
}

record(seq, "MGNT:UNDH:1:LGPSSWITCH") {
  field(DOL1, "MGNT:UNDH:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:UNDH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDH:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDH:1:LGPSCTRL")
}

record(seq, "MGNT:UNDH:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:UNDH:1:ALLSTAR")
  field(LNK1, "MGNT:UNDH:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:UNDH:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDH:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDH:1:LGPSCTRL",20,10,0,0,"MGNT:UNDH:1:LGPSCTRL")
#! Field("MGNT:UNDH:1:LGPSCTRL.FLNK",16777215,1,"MGNT:UNDH:1:LGPSCTRL.FLNK")
#! Link("MGNT:UNDH:1:LGPSCTRL.FLNK","MGNT:UNDH:1:LGPSSWITCH")
#! Field("MGNT:UNDH:1:LGPSCTRL.FFVL",16777215,1,"MGNT:UNDH:1:LGPSCTRL.FFVL")
#! Record("MGNT:UNDH:1:LGPSSWITCH",460,322,0,0,"MGNT:UNDH:1:LGPSSWITCH")
#! Field("MGNT:UNDH:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:UNDH:1:LGPSSWITCH.DOL1")
#! Link("MGNT:UNDH:1:LGPSSWITCH.DOL1","MGNT:UNDH:1:LGPSCTRL.FFVL")
#! Field("MGNT:UNDH:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:UNDH:1:LGPSSWITCH.LNK1")
#! Field("MGNT:UNDH:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:UNDH:1:LGPSSWITCH.FLNK")
#! Record("MGNT:UNDH:1:ALLLGPSSGO",240,96,0,0,"MGNT:UNDH:1:ALLLGPSSGO")
#! Field("MGNT:UNDH:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:UNDH:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:UNDH:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:UNDH:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:UNDH:1:ALLLGPSSGO.LNK1","MGNT:UNDH:1:ALLLGPSS.VAL")
#! Record("MGNT:UNDH:1:ALLLGPSS",540,102,0,0,"MGNT:UNDH:1:ALLLGPSS")
#! Field("MGNT:UNDH:1:ALLLGPSS.VAL",16777215,0,"MGNT:UNDH:1:ALLLGPSS.VAL")
#! Field("MGNT:UNDH:1:ALLLGPSS.FLNK",16777215,1,"MGNT:UNDH:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:UNDH:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:UNDH:1:QUADSWITCH")
}

record(seq, "MGNT:UNDH:1:QUADSWITCH") {
  field(DOL1, "MGNT:UNDH:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:UNDH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDH:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDH:1:QUADCTRL")
}

record(seq, "MGNT:UNDH:1:ALLQUADSGO") {
  field(DOL1, "MGNT:UNDH:1:ALLSTAR")
  field(LNK1, "MGNT:UNDH:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:UNDH:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDH:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDH:1:QUADCTRL",20,10,0,0,"MGNT:UNDH:1:QUADCTRL")
#! Field("MGNT:UNDH:1:QUADCTRL.FLNK",16777215,1,"MGNT:UNDH:1:QUADCTRL.FLNK")
#! Link("MGNT:UNDH:1:QUADCTRL.FLNK","MGNT:UNDH:1:QUADSWITCH")
#! Field("MGNT:UNDH:1:QUADCTRL.FFVL",16777215,1,"MGNT:UNDH:1:QUADCTRL.FFVL")
#! Record("MGNT:UNDH:1:QUADSWITCH",460,322,0,0,"MGNT:UNDH:1:QUADSWITCH")
#! Field("MGNT:UNDH:1:QUADSWITCH.DOL1",16777215,0,"MGNT:UNDH:1:QUADSWITCH.DOL1")
#! Link("MGNT:UNDH:1:QUADSWITCH.DOL1","MGNT:UNDH:1:QUADCTRL.FFVL")
#! Field("MGNT:UNDH:1:QUADSWITCH.LNK1",16777215,1,"MGNT:UNDH:1:QUADSWITCH.LNK1")
#! Field("MGNT:UNDH:1:QUADSWITCH.FLNK",16777215,1,"MGNT:UNDH:1:QUADSWITCH.FLNK")
#! Record("MGNT:UNDH:1:ALLQUADSGO",240,96,0,0,"MGNT:UNDH:1:ALLQUADSGO")
#! Field("MGNT:UNDH:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:UNDH:1:ALLQUADSGO.DOL1")
#! Field("MGNT:UNDH:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:UNDH:1:ALLQUADSGO.LNK1")
#! Link("MGNT:UNDH:1:ALLQUADSGO.LNK1","MGNT:UNDH:1:ALLQUADS.VAL")
#! Record("MGNT:UNDH:1:ALLQUADS",540,102,0,0,"MGNT:UNDH:1:ALLQUADS")
#! Field("MGNT:UNDH:1:ALLQUADS.VAL",16777215,0,"MGNT:UNDH:1:ALLQUADS.VAL")
#! Field("MGNT:UNDH:1:ALLQUADS.FLNK",16777215,1,"MGNT:UNDH:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:UNDH:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:UNDH:1:XCORSWITCH")
}

record(seq, "MGNT:UNDH:1:XCORSWITCH") {
  field(DOL1, "MGNT:UNDH:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:UNDH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDH:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDH:1:XCORCTRL")
}

record(seq, "MGNT:UNDH:1:ALLXCORSGO") {
  field(DOL1, "MGNT:UNDH:1:ALLSTAR")
  field(LNK1, "MGNT:UNDH:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:UNDH:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDH:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDH:1:XCORCTRL",20,10,0,0,"MGNT:UNDH:1:XCORCTRL")
#! Field("MGNT:UNDH:1:XCORCTRL.FLNK",16777215,1,"MGNT:UNDH:1:XCORCTRL.FLNK")
#! Link("MGNT:UNDH:1:XCORCTRL.FLNK","MGNT:UNDH:1:XCORSWITCH")
#! Field("MGNT:UNDH:1:XCORCTRL.FFVL",16777215,1,"MGNT:UNDH:1:XCORCTRL.FFVL")
#! Record("MGNT:UNDH:1:XCORSWITCH",460,322,0,0,"MGNT:UNDH:1:XCORSWITCH")
#! Field("MGNT:UNDH:1:XCORSWITCH.DOL1",16777215,0,"MGNT:UNDH:1:XCORSWITCH.DOL1")
#! Link("MGNT:UNDH:1:XCORSWITCH.DOL1","MGNT:UNDH:1:XCORCTRL.FFVL")
#! Field("MGNT:UNDH:1:XCORSWITCH.LNK1",16777215,1,"MGNT:UNDH:1:XCORSWITCH.LNK1")
#! Field("MGNT:UNDH:1:XCORSWITCH.FLNK",16777215,1,"MGNT:UNDH:1:XCORSWITCH.FLNK")
#! Record("MGNT:UNDH:1:ALLXCORSGO",240,96,0,0,"MGNT:UNDH:1:ALLXCORSGO")
#! Field("MGNT:UNDH:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:UNDH:1:ALLXCORSGO.DOL1")
#! Field("MGNT:UNDH:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:UNDH:1:ALLXCORSGO.LNK1")
#! Link("MGNT:UNDH:1:ALLXCORSGO.LNK1","MGNT:UNDH:1:ALLXCORS.VAL")
#! Record("MGNT:UNDH:1:ALLXCORS",540,102,0,0,"MGNT:UNDH:1:ALLXCORS")
#! Field("MGNT:UNDH:1:ALLXCORS.VAL",16777215,0,"MGNT:UNDH:1:ALLXCORS.VAL")
#! Field("MGNT:UNDH:1:ALLXCORS.FLNK",16777215,1,"MGNT:UNDH:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:UNDH:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:UNDH:1:YCORSWITCH")
}

record(seq, "MGNT:UNDH:1:YCORSWITCH") {
  field(DOL1, "MGNT:UNDH:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:UNDH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDH:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDH:1:YCORCTRL")
}

record(seq, "MGNT:UNDH:1:ALLYCORSGO") {
  field(DOL1, "MGNT:UNDH:1:ALLSTAR")
  field(LNK1, "MGNT:UNDH:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:UNDH:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDH:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDH:1:YCORCTRL",20,10,0,0,"MGNT:UNDH:1:YCORCTRL")
#! Field("MGNT:UNDH:1:YCORCTRL.FLNK",16777215,1,"MGNT:UNDH:1:YCORCTRL.FLNK")
#! Link("MGNT:UNDH:1:YCORCTRL.FLNK","MGNT:UNDH:1:YCORSWITCH")
#! Field("MGNT:UNDH:1:YCORCTRL.FFVL",16777215,1,"MGNT:UNDH:1:YCORCTRL.FFVL")
#! Record("MGNT:UNDH:1:YCORSWITCH",460,322,0,0,"MGNT:UNDH:1:YCORSWITCH")
#! Field("MGNT:UNDH:1:YCORSWITCH.DOL1",16777215,0,"MGNT:UNDH:1:YCORSWITCH.DOL1")
#! Link("MGNT:UNDH:1:YCORSWITCH.DOL1","MGNT:UNDH:1:YCORCTRL.FFVL")
#! Field("MGNT:UNDH:1:YCORSWITCH.LNK1",16777215,1,"MGNT:UNDH:1:YCORSWITCH.LNK1")
#! Field("MGNT:UNDH:1:YCORSWITCH.FLNK",16777215,1,"MGNT:UNDH:1:YCORSWITCH.FLNK")
#! Record("MGNT:UNDH:1:ALLYCORSGO",240,96,0,0,"MGNT:UNDH:1:ALLYCORSGO")
#! Field("MGNT:UNDH:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:UNDH:1:ALLYCORSGO.DOL1")
#! Field("MGNT:UNDH:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:UNDH:1:ALLYCORSGO.LNK1")
#! Link("MGNT:UNDH:1:ALLYCORSGO.LNK1","MGNT:UNDH:1:ALLYCORS.VAL")
#! Record("MGNT:UNDH:1:ALLYCORS",540,102,0,0,"MGNT:UNDH:1:ALLYCORS")
#! Field("MGNT:UNDH:1:ALLYCORS.VAL",16777215,0,"MGNT:UNDH:1:ALLYCORS.VAL")
#! Field("MGNT:UNDH:1:ALLYCORS.FLNK",16777215,1,"MGNT:UNDH:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:UNDH:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:UNDH:1:SOLNSWITCH")
}

record(seq, "MGNT:UNDH:1:SOLNSWITCH") {
  field(DOL1, "MGNT:UNDH:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:UNDH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDH:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDH:1:SOLNCTRL")
}

record(seq, "MGNT:UNDH:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:UNDH:1:ALLSTAR")
  field(LNK1, "MGNT:UNDH:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:UNDH:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDH:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDH:1:SOLNCTRL",20,10,0,0,"MGNT:UNDH:1:SOLNCTRL")
#! Field("MGNT:UNDH:1:SOLNCTRL.FLNK",16777215,1,"MGNT:UNDH:1:SOLNCTRL.FLNK")
#! Link("MGNT:UNDH:1:SOLNCTRL.FLNK","MGNT:UNDH:1:SOLNSWITCH")
#! Field("MGNT:UNDH:1:SOLNCTRL.FFVL",16777215,1,"MGNT:UNDH:1:SOLNCTRL.FFVL")
#! Record("MGNT:UNDH:1:SOLNSWITCH",460,322,0,0,"MGNT:UNDH:1:SOLNSWITCH")
#! Field("MGNT:UNDH:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:UNDH:1:SOLNSWITCH.DOL1")
#! Link("MGNT:UNDH:1:SOLNSWITCH.DOL1","MGNT:UNDH:1:SOLNCTRL.FFVL")
#! Field("MGNT:UNDH:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:UNDH:1:SOLNSWITCH.LNK1")
#! Field("MGNT:UNDH:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:UNDH:1:SOLNSWITCH.FLNK")
#! Record("MGNT:UNDH:1:ALLSOLNSGO",240,96,0,0,"MGNT:UNDH:1:ALLSOLNSGO")
#! Field("MGNT:UNDH:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:UNDH:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:UNDH:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:UNDH:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:UNDH:1:ALLSOLNSGO.LNK1","MGNT:UNDH:1:ALLSOLNS.VAL")
#! Record("MGNT:UNDH:1:ALLSOLNS",540,102,0,0,"MGNT:UNDH:1:ALLSOLNS")
#! Field("MGNT:UNDH:1:ALLSOLNS.VAL",16777215,0,"MGNT:UNDH:1:ALLSOLNS.VAL")
#! Field("MGNT:UNDH:1:ALLSOLNS.FLNK",16777215,1,"MGNT:UNDH:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:UNDH:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:UNDH:1:KICKSWITCH")
}

record(seq, "MGNT:UNDH:1:KICKSWITCH") {
  field(DOL1, "MGNT:UNDH:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:UNDH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDH:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDH:1:KICKCTRL")
}

record(seq, "MGNT:UNDH:1:ALLKICKSGO") {
  field(DOL1, "MGNT:UNDH:1:ALLSTAR")
  field(LNK1, "MGNT:UNDH:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:UNDH:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDH:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDH:1:KICKCTRL",20,10,0,0,"MGNT:UNDH:1:KICKCTRL")
#! Field("MGNT:UNDH:1:KICKCTRL.FLNK",16777215,1,"MGNT:UNDH:1:KICKCTRL.FLNK")
#! Link("MGNT:UNDH:1:KICKCTRL.FLNK","MGNT:UNDH:1:KICKSWITCH")
#! Field("MGNT:UNDH:1:KICKCTRL.FFVL",16777215,1,"MGNT:UNDH:1:KICKCTRL.FFVL")
#! Record("MGNT:UNDH:1:KICKSWITCH",460,322,0,0,"MGNT:UNDH:1:KICKSWITCH")
#! Field("MGNT:UNDH:1:KICKSWITCH.DOL1",16777215,0,"MGNT:UNDH:1:KICKSWITCH.DOL1")
#! Link("MGNT:UNDH:1:KICKSWITCH.DOL1","MGNT:UNDH:1:KICKCTRL.FFVL")
#! Field("MGNT:UNDH:1:KICKSWITCH.LNK1",16777215,1,"MGNT:UNDH:1:KICKSWITCH.LNK1")
#! Field("MGNT:UNDH:1:KICKSWITCH.FLNK",16777215,1,"MGNT:UNDH:1:KICKSWITCH.FLNK")
#! Record("MGNT:UNDH:1:ALLKICKSGO",240,96,0,0,"MGNT:UNDH:1:ALLKICKSGO")
#! Field("MGNT:UNDH:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:UNDH:1:ALLKICKSGO.DOL1")
#! Field("MGNT:UNDH:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:UNDH:1:ALLKICKSGO.LNK1")
#! Link("MGNT:UNDH:1:ALLKICKSGO.LNK1","MGNT:UNDH:1:ALLKICKS.VAL")
#! Record("MGNT:UNDH:1:ALLKICKS",540,102,0,0,"MGNT:UNDH:1:ALLKICKS")
#! Field("MGNT:UNDH:1:ALLKICKS.VAL",16777215,0,"MGNT:UNDH:1:ALLKICKS.VAL")
#! Field("MGNT:UNDH:1:ALLKICKS.FLNK",16777215,1,"MGNT:UNDH:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:UNDH:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:UNDH:1:SEXTSWITCH")
}

record(seq, "MGNT:UNDH:1:SEXTSWITCH") {
  field(DOL1, "MGNT:UNDH:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:UNDH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDH:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDH:1:SEXTCTRL")
}

record(seq, "MGNT:UNDH:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:UNDH:1:ALLSTAR")
  field(LNK1, "MGNT:UNDH:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:UNDH:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDH:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDH:1:SEXTCTRL",20,10,0,0,"MGNT:UNDH:1:SEXTCTRL")
#! Field("MGNT:UNDH:1:SEXTCTRL.FLNK",16777215,1,"MGNT:UNDH:1:SEXTCTRL.FLNK")
#! Link("MGNT:UNDH:1:SEXTCTRL.FLNK","MGNT:UNDH:1:SEXTSWITCH")
#! Field("MGNT:UNDH:1:SEXTCTRL.FFVL",16777215,1,"MGNT:UNDH:1:SEXTCTRL.FFVL")
#! Record("MGNT:UNDH:1:SEXTSWITCH",460,322,0,0,"MGNT:UNDH:1:SEXTSWITCH")
#! Field("MGNT:UNDH:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:UNDH:1:SEXTSWITCH.DOL1")
#! Link("MGNT:UNDH:1:SEXTSWITCH.DOL1","MGNT:UNDH:1:SEXTCTRL.FFVL")
#! Field("MGNT:UNDH:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:UNDH:1:SEXTSWITCH.LNK1")
#! Field("MGNT:UNDH:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:UNDH:1:SEXTSWITCH.FLNK")
#! Record("MGNT:UNDH:1:ALLSEXTSGO",240,96,0,0,"MGNT:UNDH:1:ALLSEXTSGO")
#! Field("MGNT:UNDH:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:UNDH:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:UNDH:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:UNDH:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:UNDH:1:ALLSEXTSGO.LNK1","MGNT:UNDH:1:ALLSEXTS.VAL")
#! Record("MGNT:UNDH:1:ALLSEXTS",540,102,0,0,"MGNT:UNDH:1:ALLSEXTS")
#! Field("MGNT:UNDH:1:ALLSEXTS.VAL",16777215,0,"MGNT:UNDH:1:ALLSEXTS.VAL")
#! Field("MGNT:UNDH:1:ALLSEXTS.FLNK",16777215,1,"MGNT:UNDH:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:UNDS:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:UNDS:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:UNDS:1:CTRL CA PP")
  field(LNK2, "MGNT:UNDS:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:UNDS:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:UNDS:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:UNDS:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:UNDS:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:UNDS:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:UNDS:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:UNDS:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:UNDS:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:UNDS:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:UNDS:1:ALLSWITCH")
}

record(seq, "MGNT:UNDS:1:ALLSWITCH") {
  field(DOL1, "MGNT:UNDS:1:CTRL.FFVL")
  field(LNK1, "MGNT:UNDS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDS:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDS:1:CTRL")
}

record(bo, "MGNT:UNDS:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:UNDS:1:ALLSTARGO")
}

record(fanout, "MGNT:UNDS:1:ALLSTARGO") {
  field(LNK1, "MGNT:UNDS:1:ALLBENDSGO")
  field(LNK2, "MGNT:UNDS:1:ALLBTRMSGO")
  field(LNK3, "MGNT:UNDS:1:ALLLGPSSGO")
  field(LNK4, "MGNT:UNDS:1:ALLQUADSGO")
  field(LNK5, "MGNT:UNDS:1:ALLXCORSGO")
  field(LNK6, "MGNT:UNDS:1:ALLYCORSGO")
  field(FLNK, "MGNT:UNDS:1:ALLSTARGO_2")
}
record(fanout, "MGNT:UNDS:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:UNDS:1:ALLSOLNSGO")
  field(LNK2, "MGNT:UNDS:1:ALLKICKSGO")
  field(LNK3, "MGNT:UNDS:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:UNDS:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:UNDS:1:BENDSWITCH")
}

record(seq, "MGNT:UNDS:1:BENDSWITCH") {
  field(DOL1, "MGNT:UNDS:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:UNDS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDS:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDS:1:BENDCTRL")
}

record(seq, "MGNT:UNDS:1:ALLBENDSGO") {
  field(DOL1, "MGNT:UNDS:1:ALLSTAR")
  field(LNK1, "MGNT:UNDS:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:UNDS:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDS:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDS:1:BENDCTRL",20,10,0,0,"MGNT:UNDS:1:BENDCTRL")
#! Field("MGNT:UNDS:1:BENDCTRL.FLNK",16777215,1,"MGNT:UNDS:1:BENDCTRL.FLNK")
#! Link("MGNT:UNDS:1:BENDCTRL.FLNK","MGNT:UNDS:1:BENDSWITCH")
#! Field("MGNT:UNDS:1:BENDCTRL.FFVL",16777215,1,"MGNT:UNDS:1:BENDCTRL.FFVL")
#! Record("MGNT:UNDS:1:BENDSWITCH",460,322,0,0,"MGNT:UNDS:1:BENDSWITCH")
#! Field("MGNT:UNDS:1:BENDSWITCH.DOL1",16777215,0,"MGNT:UNDS:1:BENDSWITCH.DOL1")
#! Link("MGNT:UNDS:1:BENDSWITCH.DOL1","MGNT:UNDS:1:BENDCTRL.FFVL")
#! Field("MGNT:UNDS:1:BENDSWITCH.LNK1",16777215,1,"MGNT:UNDS:1:BENDSWITCH.LNK1")
#! Field("MGNT:UNDS:1:BENDSWITCH.FLNK",16777215,1,"MGNT:UNDS:1:BENDSWITCH.FLNK")
#! Record("MGNT:UNDS:1:ALLBENDSGO",240,96,0,0,"MGNT:UNDS:1:ALLBENDSGO")
#! Field("MGNT:UNDS:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:UNDS:1:ALLBENDSGO.DOL1")
#! Field("MGNT:UNDS:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:UNDS:1:ALLBENDSGO.LNK1")
#! Link("MGNT:UNDS:1:ALLBENDSGO.LNK1","MGNT:UNDS:1:ALLBENDS.VAL")
#! Record("MGNT:UNDS:1:ALLBENDS",540,102,0,0,"MGNT:UNDS:1:ALLBENDS")
#! Field("MGNT:UNDS:1:ALLBENDS.VAL",16777215,0,"MGNT:UNDS:1:ALLBENDS.VAL")
#! Field("MGNT:UNDS:1:ALLBENDS.FLNK",16777215,1,"MGNT:UNDS:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:UNDS:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:UNDS:1:BTRMSWITCH")
}

record(seq, "MGNT:UNDS:1:BTRMSWITCH") {
  field(DOL1, "MGNT:UNDS:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:UNDS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDS:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDS:1:BTRMCTRL")
}

record(seq, "MGNT:UNDS:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:UNDS:1:ALLSTAR")
  field(LNK1, "MGNT:UNDS:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:UNDS:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDS:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDS:1:BTRMCTRL",20,10,0,0,"MGNT:UNDS:1:BTRMCTRL")
#! Field("MGNT:UNDS:1:BTRMCTRL.FLNK",16777215,1,"MGNT:UNDS:1:BTRMCTRL.FLNK")
#! Link("MGNT:UNDS:1:BTRMCTRL.FLNK","MGNT:UNDS:1:BTRMSWITCH")
#! Field("MGNT:UNDS:1:BTRMCTRL.FFVL",16777215,1,"MGNT:UNDS:1:BTRMCTRL.FFVL")
#! Record("MGNT:UNDS:1:BTRMSWITCH",460,322,0,0,"MGNT:UNDS:1:BTRMSWITCH")
#! Field("MGNT:UNDS:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:UNDS:1:BTRMSWITCH.DOL1")
#! Link("MGNT:UNDS:1:BTRMSWITCH.DOL1","MGNT:UNDS:1:BTRMCTRL.FFVL")
#! Field("MGNT:UNDS:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:UNDS:1:BTRMSWITCH.LNK1")
#! Field("MGNT:UNDS:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:UNDS:1:BTRMSWITCH.FLNK")
#! Record("MGNT:UNDS:1:ALLBTRMSGO",240,96,0,0,"MGNT:UNDS:1:ALLBTRMSGO")
#! Field("MGNT:UNDS:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:UNDS:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:UNDS:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:UNDS:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:UNDS:1:ALLBTRMSGO.LNK1","MGNT:UNDS:1:ALLBTRMS.VAL")
#! Record("MGNT:UNDS:1:ALLBTRMS",540,102,0,0,"MGNT:UNDS:1:ALLBTRMS")
#! Field("MGNT:UNDS:1:ALLBTRMS.VAL",16777215,0,"MGNT:UNDS:1:ALLBTRMS.VAL")
#! Field("MGNT:UNDS:1:ALLBTRMS.FLNK",16777215,1,"MGNT:UNDS:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:UNDS:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:UNDS:1:LGPSSWITCH")
}

record(seq, "MGNT:UNDS:1:LGPSSWITCH") {
  field(DOL1, "MGNT:UNDS:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:UNDS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDS:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDS:1:LGPSCTRL")
}

record(seq, "MGNT:UNDS:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:UNDS:1:ALLSTAR")
  field(LNK1, "MGNT:UNDS:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:UNDS:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDS:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDS:1:LGPSCTRL",20,10,0,0,"MGNT:UNDS:1:LGPSCTRL")
#! Field("MGNT:UNDS:1:LGPSCTRL.FLNK",16777215,1,"MGNT:UNDS:1:LGPSCTRL.FLNK")
#! Link("MGNT:UNDS:1:LGPSCTRL.FLNK","MGNT:UNDS:1:LGPSSWITCH")
#! Field("MGNT:UNDS:1:LGPSCTRL.FFVL",16777215,1,"MGNT:UNDS:1:LGPSCTRL.FFVL")
#! Record("MGNT:UNDS:1:LGPSSWITCH",460,322,0,0,"MGNT:UNDS:1:LGPSSWITCH")
#! Field("MGNT:UNDS:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:UNDS:1:LGPSSWITCH.DOL1")
#! Link("MGNT:UNDS:1:LGPSSWITCH.DOL1","MGNT:UNDS:1:LGPSCTRL.FFVL")
#! Field("MGNT:UNDS:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:UNDS:1:LGPSSWITCH.LNK1")
#! Field("MGNT:UNDS:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:UNDS:1:LGPSSWITCH.FLNK")
#! Record("MGNT:UNDS:1:ALLLGPSSGO",240,96,0,0,"MGNT:UNDS:1:ALLLGPSSGO")
#! Field("MGNT:UNDS:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:UNDS:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:UNDS:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:UNDS:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:UNDS:1:ALLLGPSSGO.LNK1","MGNT:UNDS:1:ALLLGPSS.VAL")
#! Record("MGNT:UNDS:1:ALLLGPSS",540,102,0,0,"MGNT:UNDS:1:ALLLGPSS")
#! Field("MGNT:UNDS:1:ALLLGPSS.VAL",16777215,0,"MGNT:UNDS:1:ALLLGPSS.VAL")
#! Field("MGNT:UNDS:1:ALLLGPSS.FLNK",16777215,1,"MGNT:UNDS:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:UNDS:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:UNDS:1:QUADSWITCH")
}

record(seq, "MGNT:UNDS:1:QUADSWITCH") {
  field(DOL1, "MGNT:UNDS:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:UNDS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDS:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDS:1:QUADCTRL")
}

record(seq, "MGNT:UNDS:1:ALLQUADSGO") {
  field(DOL1, "MGNT:UNDS:1:ALLSTAR")
  field(LNK1, "MGNT:UNDS:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:UNDS:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDS:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDS:1:QUADCTRL",20,10,0,0,"MGNT:UNDS:1:QUADCTRL")
#! Field("MGNT:UNDS:1:QUADCTRL.FLNK",16777215,1,"MGNT:UNDS:1:QUADCTRL.FLNK")
#! Link("MGNT:UNDS:1:QUADCTRL.FLNK","MGNT:UNDS:1:QUADSWITCH")
#! Field("MGNT:UNDS:1:QUADCTRL.FFVL",16777215,1,"MGNT:UNDS:1:QUADCTRL.FFVL")
#! Record("MGNT:UNDS:1:QUADSWITCH",460,322,0,0,"MGNT:UNDS:1:QUADSWITCH")
#! Field("MGNT:UNDS:1:QUADSWITCH.DOL1",16777215,0,"MGNT:UNDS:1:QUADSWITCH.DOL1")
#! Link("MGNT:UNDS:1:QUADSWITCH.DOL1","MGNT:UNDS:1:QUADCTRL.FFVL")
#! Field("MGNT:UNDS:1:QUADSWITCH.LNK1",16777215,1,"MGNT:UNDS:1:QUADSWITCH.LNK1")
#! Field("MGNT:UNDS:1:QUADSWITCH.FLNK",16777215,1,"MGNT:UNDS:1:QUADSWITCH.FLNK")
#! Record("MGNT:UNDS:1:ALLQUADSGO",240,96,0,0,"MGNT:UNDS:1:ALLQUADSGO")
#! Field("MGNT:UNDS:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:UNDS:1:ALLQUADSGO.DOL1")
#! Field("MGNT:UNDS:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:UNDS:1:ALLQUADSGO.LNK1")
#! Link("MGNT:UNDS:1:ALLQUADSGO.LNK1","MGNT:UNDS:1:ALLQUADS.VAL")
#! Record("MGNT:UNDS:1:ALLQUADS",540,102,0,0,"MGNT:UNDS:1:ALLQUADS")
#! Field("MGNT:UNDS:1:ALLQUADS.VAL",16777215,0,"MGNT:UNDS:1:ALLQUADS.VAL")
#! Field("MGNT:UNDS:1:ALLQUADS.FLNK",16777215,1,"MGNT:UNDS:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:UNDS:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:UNDS:1:XCORSWITCH")
}

record(seq, "MGNT:UNDS:1:XCORSWITCH") {
  field(DOL1, "MGNT:UNDS:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:UNDS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDS:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDS:1:XCORCTRL")
}

record(seq, "MGNT:UNDS:1:ALLXCORSGO") {
  field(DOL1, "MGNT:UNDS:1:ALLSTAR")
  field(LNK1, "MGNT:UNDS:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:UNDS:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDS:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDS:1:XCORCTRL",20,10,0,0,"MGNT:UNDS:1:XCORCTRL")
#! Field("MGNT:UNDS:1:XCORCTRL.FLNK",16777215,1,"MGNT:UNDS:1:XCORCTRL.FLNK")
#! Link("MGNT:UNDS:1:XCORCTRL.FLNK","MGNT:UNDS:1:XCORSWITCH")
#! Field("MGNT:UNDS:1:XCORCTRL.FFVL",16777215,1,"MGNT:UNDS:1:XCORCTRL.FFVL")
#! Record("MGNT:UNDS:1:XCORSWITCH",460,322,0,0,"MGNT:UNDS:1:XCORSWITCH")
#! Field("MGNT:UNDS:1:XCORSWITCH.DOL1",16777215,0,"MGNT:UNDS:1:XCORSWITCH.DOL1")
#! Link("MGNT:UNDS:1:XCORSWITCH.DOL1","MGNT:UNDS:1:XCORCTRL.FFVL")
#! Field("MGNT:UNDS:1:XCORSWITCH.LNK1",16777215,1,"MGNT:UNDS:1:XCORSWITCH.LNK1")
#! Field("MGNT:UNDS:1:XCORSWITCH.FLNK",16777215,1,"MGNT:UNDS:1:XCORSWITCH.FLNK")
#! Record("MGNT:UNDS:1:ALLXCORSGO",240,96,0,0,"MGNT:UNDS:1:ALLXCORSGO")
#! Field("MGNT:UNDS:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:UNDS:1:ALLXCORSGO.DOL1")
#! Field("MGNT:UNDS:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:UNDS:1:ALLXCORSGO.LNK1")
#! Link("MGNT:UNDS:1:ALLXCORSGO.LNK1","MGNT:UNDS:1:ALLXCORS.VAL")
#! Record("MGNT:UNDS:1:ALLXCORS",540,102,0,0,"MGNT:UNDS:1:ALLXCORS")
#! Field("MGNT:UNDS:1:ALLXCORS.VAL",16777215,0,"MGNT:UNDS:1:ALLXCORS.VAL")
#! Field("MGNT:UNDS:1:ALLXCORS.FLNK",16777215,1,"MGNT:UNDS:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:UNDS:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:UNDS:1:YCORSWITCH")
}

record(seq, "MGNT:UNDS:1:YCORSWITCH") {
  field(DOL1, "MGNT:UNDS:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:UNDS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDS:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDS:1:YCORCTRL")
}

record(seq, "MGNT:UNDS:1:ALLYCORSGO") {
  field(DOL1, "MGNT:UNDS:1:ALLSTAR")
  field(LNK1, "MGNT:UNDS:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:UNDS:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDS:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDS:1:YCORCTRL",20,10,0,0,"MGNT:UNDS:1:YCORCTRL")
#! Field("MGNT:UNDS:1:YCORCTRL.FLNK",16777215,1,"MGNT:UNDS:1:YCORCTRL.FLNK")
#! Link("MGNT:UNDS:1:YCORCTRL.FLNK","MGNT:UNDS:1:YCORSWITCH")
#! Field("MGNT:UNDS:1:YCORCTRL.FFVL",16777215,1,"MGNT:UNDS:1:YCORCTRL.FFVL")
#! Record("MGNT:UNDS:1:YCORSWITCH",460,322,0,0,"MGNT:UNDS:1:YCORSWITCH")
#! Field("MGNT:UNDS:1:YCORSWITCH.DOL1",16777215,0,"MGNT:UNDS:1:YCORSWITCH.DOL1")
#! Link("MGNT:UNDS:1:YCORSWITCH.DOL1","MGNT:UNDS:1:YCORCTRL.FFVL")
#! Field("MGNT:UNDS:1:YCORSWITCH.LNK1",16777215,1,"MGNT:UNDS:1:YCORSWITCH.LNK1")
#! Field("MGNT:UNDS:1:YCORSWITCH.FLNK",16777215,1,"MGNT:UNDS:1:YCORSWITCH.FLNK")
#! Record("MGNT:UNDS:1:ALLYCORSGO",240,96,0,0,"MGNT:UNDS:1:ALLYCORSGO")
#! Field("MGNT:UNDS:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:UNDS:1:ALLYCORSGO.DOL1")
#! Field("MGNT:UNDS:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:UNDS:1:ALLYCORSGO.LNK1")
#! Link("MGNT:UNDS:1:ALLYCORSGO.LNK1","MGNT:UNDS:1:ALLYCORS.VAL")
#! Record("MGNT:UNDS:1:ALLYCORS",540,102,0,0,"MGNT:UNDS:1:ALLYCORS")
#! Field("MGNT:UNDS:1:ALLYCORS.VAL",16777215,0,"MGNT:UNDS:1:ALLYCORS.VAL")
#! Field("MGNT:UNDS:1:ALLYCORS.FLNK",16777215,1,"MGNT:UNDS:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:UNDS:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:UNDS:1:SOLNSWITCH")
}

record(seq, "MGNT:UNDS:1:SOLNSWITCH") {
  field(DOL1, "MGNT:UNDS:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:UNDS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDS:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDS:1:SOLNCTRL")
}

record(seq, "MGNT:UNDS:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:UNDS:1:ALLSTAR")
  field(LNK1, "MGNT:UNDS:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:UNDS:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDS:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDS:1:SOLNCTRL",20,10,0,0,"MGNT:UNDS:1:SOLNCTRL")
#! Field("MGNT:UNDS:1:SOLNCTRL.FLNK",16777215,1,"MGNT:UNDS:1:SOLNCTRL.FLNK")
#! Link("MGNT:UNDS:1:SOLNCTRL.FLNK","MGNT:UNDS:1:SOLNSWITCH")
#! Field("MGNT:UNDS:1:SOLNCTRL.FFVL",16777215,1,"MGNT:UNDS:1:SOLNCTRL.FFVL")
#! Record("MGNT:UNDS:1:SOLNSWITCH",460,322,0,0,"MGNT:UNDS:1:SOLNSWITCH")
#! Field("MGNT:UNDS:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:UNDS:1:SOLNSWITCH.DOL1")
#! Link("MGNT:UNDS:1:SOLNSWITCH.DOL1","MGNT:UNDS:1:SOLNCTRL.FFVL")
#! Field("MGNT:UNDS:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:UNDS:1:SOLNSWITCH.LNK1")
#! Field("MGNT:UNDS:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:UNDS:1:SOLNSWITCH.FLNK")
#! Record("MGNT:UNDS:1:ALLSOLNSGO",240,96,0,0,"MGNT:UNDS:1:ALLSOLNSGO")
#! Field("MGNT:UNDS:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:UNDS:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:UNDS:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:UNDS:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:UNDS:1:ALLSOLNSGO.LNK1","MGNT:UNDS:1:ALLSOLNS.VAL")
#! Record("MGNT:UNDS:1:ALLSOLNS",540,102,0,0,"MGNT:UNDS:1:ALLSOLNS")
#! Field("MGNT:UNDS:1:ALLSOLNS.VAL",16777215,0,"MGNT:UNDS:1:ALLSOLNS.VAL")
#! Field("MGNT:UNDS:1:ALLSOLNS.FLNK",16777215,1,"MGNT:UNDS:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:UNDS:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:UNDS:1:KICKSWITCH")
}

record(seq, "MGNT:UNDS:1:KICKSWITCH") {
  field(DOL1, "MGNT:UNDS:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:UNDS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDS:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDS:1:KICKCTRL")
}

record(seq, "MGNT:UNDS:1:ALLKICKSGO") {
  field(DOL1, "MGNT:UNDS:1:ALLSTAR")
  field(LNK1, "MGNT:UNDS:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:UNDS:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDS:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDS:1:KICKCTRL",20,10,0,0,"MGNT:UNDS:1:KICKCTRL")
#! Field("MGNT:UNDS:1:KICKCTRL.FLNK",16777215,1,"MGNT:UNDS:1:KICKCTRL.FLNK")
#! Link("MGNT:UNDS:1:KICKCTRL.FLNK","MGNT:UNDS:1:KICKSWITCH")
#! Field("MGNT:UNDS:1:KICKCTRL.FFVL",16777215,1,"MGNT:UNDS:1:KICKCTRL.FFVL")
#! Record("MGNT:UNDS:1:KICKSWITCH",460,322,0,0,"MGNT:UNDS:1:KICKSWITCH")
#! Field("MGNT:UNDS:1:KICKSWITCH.DOL1",16777215,0,"MGNT:UNDS:1:KICKSWITCH.DOL1")
#! Link("MGNT:UNDS:1:KICKSWITCH.DOL1","MGNT:UNDS:1:KICKCTRL.FFVL")
#! Field("MGNT:UNDS:1:KICKSWITCH.LNK1",16777215,1,"MGNT:UNDS:1:KICKSWITCH.LNK1")
#! Field("MGNT:UNDS:1:KICKSWITCH.FLNK",16777215,1,"MGNT:UNDS:1:KICKSWITCH.FLNK")
#! Record("MGNT:UNDS:1:ALLKICKSGO",240,96,0,0,"MGNT:UNDS:1:ALLKICKSGO")
#! Field("MGNT:UNDS:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:UNDS:1:ALLKICKSGO.DOL1")
#! Field("MGNT:UNDS:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:UNDS:1:ALLKICKSGO.LNK1")
#! Link("MGNT:UNDS:1:ALLKICKSGO.LNK1","MGNT:UNDS:1:ALLKICKS.VAL")
#! Record("MGNT:UNDS:1:ALLKICKS",540,102,0,0,"MGNT:UNDS:1:ALLKICKS")
#! Field("MGNT:UNDS:1:ALLKICKS.VAL",16777215,0,"MGNT:UNDS:1:ALLKICKS.VAL")
#! Field("MGNT:UNDS:1:ALLKICKS.FLNK",16777215,1,"MGNT:UNDS:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:UNDS:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:UNDS:1:SEXTSWITCH")
}

record(seq, "MGNT:UNDS:1:SEXTSWITCH") {
  field(DOL1, "MGNT:UNDS:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:UNDS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDS:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDS:1:SEXTCTRL")
}

record(seq, "MGNT:UNDS:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:UNDS:1:ALLSTAR")
  field(LNK1, "MGNT:UNDS:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:UNDS:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDS:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:UNDS:1:SEXTCTRL",20,10,0,0,"MGNT:UNDS:1:SEXTCTRL")
#! Field("MGNT:UNDS:1:SEXTCTRL.FLNK",16777215,1,"MGNT:UNDS:1:SEXTCTRL.FLNK")
#! Link("MGNT:UNDS:1:SEXTCTRL.FLNK","MGNT:UNDS:1:SEXTSWITCH")
#! Field("MGNT:UNDS:1:SEXTCTRL.FFVL",16777215,1,"MGNT:UNDS:1:SEXTCTRL.FFVL")
#! Record("MGNT:UNDS:1:SEXTSWITCH",460,322,0,0,"MGNT:UNDS:1:SEXTSWITCH")
#! Field("MGNT:UNDS:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:UNDS:1:SEXTSWITCH.DOL1")
#! Link("MGNT:UNDS:1:SEXTSWITCH.DOL1","MGNT:UNDS:1:SEXTCTRL.FFVL")
#! Field("MGNT:UNDS:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:UNDS:1:SEXTSWITCH.LNK1")
#! Field("MGNT:UNDS:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:UNDS:1:SEXTSWITCH.FLNK")
#! Record("MGNT:UNDS:1:ALLSEXTSGO",240,96,0,0,"MGNT:UNDS:1:ALLSEXTSGO")
#! Field("MGNT:UNDS:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:UNDS:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:UNDS:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:UNDS:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:UNDS:1:ALLSEXTSGO.LNK1","MGNT:UNDS:1:ALLSEXTS.VAL")
#! Record("MGNT:UNDS:1:ALLSEXTS",540,102,0,0,"MGNT:UNDS:1:ALLSEXTS")
#! Field("MGNT:UNDS:1:ALLSEXTS.VAL",16777215,0,"MGNT:UNDS:1:ALLSEXTS.VAL")
#! Field("MGNT:UNDS:1:ALLSEXTS.FLNK",16777215,1,"MGNT:UNDS:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND



record(longout, "MGNT:UNDH:2:CTRLSWITCH") {
}


# The LNK# (1-3) MUST corresponsds to the magent type (efc:x=2, efc:y=3).
# For example, MGNT_TYPE_YCOR is defined as 3 and is LNK3 below.
# If the LNK order is changes you will need to make the 
# corresponding change to the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar_efc.substitutions
# The field FFVL value in MGNT:<LOCA>:2: CTRLCLEAR MUST be set 
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:UNDS:2:ALLSWITCH
#
record(seq, "MGNT:UNDH:2:CTRLCLEAR") {
  field(DESC, "All function go")
  field(LNK1, "MGNT:UNDH:2:CTRL CA PP")
  field(LNK2, "MGNT:UNDH:2:XCORCTRL CA PP")
  field(LNK3, "MGNT:UNDH:2:YCORCTRL CA PP")
}

record(mbbo, "MGNT:UNDH:2:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL,  "0")
  field(ZRST, "Ready")
  field(ONST, "OFFLINE")
  field(TWST, "ONLINE")
  field(THST, "DAC_ZERO")
  field(FRST, "RESET")
  field(FVST, "LOAD_IDES")
  field(ZRVL, "0")
  field(ONVL, "10")
  field(TWVL, "9")
  field(THVL, "7")
  field(FRVL, "8")
  field(FVVL, "12")
  field(FFVL, "1")
  field(FLNK, "MGNT:UNDH:2:ALLSWITCH")
}

record(seq, "MGNT:UNDH:2:ALLSWITCH") {
  field(DOL1, "MGNT:UNDH:2:CTRL.FFVL")
  field(LNK1, "MGNT:UNDH:2:CTRLSWITCH PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDH:2:CTRL")
  field(FLNK, "MGNT:UNDH:2:ALLFUNCGO PP NMS")
}

record(bo, "MGNT:UNDH:2:ALLSTAR") {
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDH:2:ALLSTARGO")
}

record(fanout, "MGNT:UNDH:2:ALLSTARGO") {
  field(LNK1, "MGNT:UNDH:2:ALLXCORSGO")
  field(LNK2, "MGNT:UNDH:2:ALLYCORSGO")
}

# In the PV MGNT:<LOCA>:2:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically, 
# MGNT_TYPE_XCOR equals 1 and is LNK1 
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:UNDH:2:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "OFFLINE")
  field(TWST, "ONLINE")
  field(THST, "DAC_ZERO")
  field(FRST, "RESET")
  field(FVST, "LOAD_IDES")
  field(ZRVL, "0")
  field(ONVL, "10")
  field(TWVL, "9")
  field(THVL, "7")
  field(FRVL, "8")
  field(FVVL, "12")
  field(FFVL, "2")
  field(FLNK, "MGNT:UNDH:2:XCORSWITCH")
}

record(seq, "MGNT:UNDH:2:XCORSWITCH") {
  field(DOL1, "MGNT:UNDH:2:XCORCTRL.FFVL")
  field(LNK1, "MGNT:UNDH:2:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDH:2:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDH:2:XCORCTRL")
}

record(seq, "MGNT:UNDH:2:ALLXCORSGO") {
  field(DOL1, "MGNT:UNDH:2:ALLSTAR")
  field(LNK1, "MGNT:UNDH:2:ALLXCORS PP NMS")
}

record(bo, "MGNT:UNDH:2:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDH:2:ALLXCORSSEL")
}

# End of file

# In the PV MGNT:<LOCA>:2:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically, 
# MGNT_TYPE_XCOR equals 1 and is LNK1 
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:UNDH:2:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "OFFLINE")
  field(TWST, "ONLINE")
  field(THST, "DAC_ZERO")
  field(FRST, "RESET")
  field(FVST, "LOAD_IDES")
  field(ZRVL, "0")
  field(ONVL, "10")
  field(TWVL, "9")
  field(THVL, "7")
  field(FRVL, "8")
  field(FVVL, "12")
  field(FFVL, "3")
  field(FLNK, "MGNT:UNDH:2:YCORSWITCH")
}

record(seq, "MGNT:UNDH:2:YCORSWITCH") {
  field(DOL1, "MGNT:UNDH:2:YCORCTRL.FFVL")
  field(LNK1, "MGNT:UNDH:2:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDH:2:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDH:2:YCORCTRL")
}

record(seq, "MGNT:UNDH:2:ALLYCORSGO") {
  field(DOL1, "MGNT:UNDH:2:ALLSTAR")
  field(LNK1, "MGNT:UNDH:2:ALLYCORS PP NMS")
}

record(bo, "MGNT:UNDH:2:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDH:2:ALLYCORSSEL")
}

# End of file
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND



record(longout, "MGNT:UNDS:2:CTRLSWITCH") {
}


# The LNK# (1-3) MUST corresponsds to the magent type (efc:x=2, efc:y=3).
# For example, MGNT_TYPE_YCOR is defined as 3 and is LNK3 below.
# If the LNK order is changes you will need to make the 
# corresponding change to the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar_efc.substitutions
# The field FFVL value in MGNT:<LOCA>:2: CTRLCLEAR MUST be set 
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:UNDS:2:ALLSWITCH
#
record(seq, "MGNT:UNDS:2:CTRLCLEAR") {
  field(DESC, "All function go")
  field(LNK1, "MGNT:UNDS:2:CTRL CA PP")
  field(LNK2, "MGNT:UNDS:2:XCORCTRL CA PP")
  field(LNK3, "MGNT:UNDS:2:YCORCTRL CA PP")
}

record(mbbo, "MGNT:UNDS:2:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL,  "0")
  field(ZRST, "Ready")
  field(ONST, "OFFLINE")
  field(TWST, "ONLINE")
  field(THST, "DAC_ZERO")
  field(FRST, "RESET")
  field(FVST, "LOAD_IDES")
  field(ZRVL, "0")
  field(ONVL, "10")
  field(TWVL, "9")
  field(THVL, "7")
  field(FRVL, "8")
  field(FVVL, "12")
  field(FFVL, "1")
  field(FLNK, "MGNT:UNDS:2:ALLSWITCH")
}

record(seq, "MGNT:UNDS:2:ALLSWITCH") {
  field(DOL1, "MGNT:UNDS:2:CTRL.FFVL")
  field(LNK1, "MGNT:UNDS:2:CTRLSWITCH PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDS:2:CTRL")
  field(FLNK, "MGNT:UNDS:2:ALLFUNCGO PP NMS")
}

record(bo, "MGNT:UNDS:2:ALLSTAR") {
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDS:2:ALLSTARGO")
}

record(fanout, "MGNT:UNDS:2:ALLSTARGO") {
  field(LNK1, "MGNT:UNDS:2:ALLXCORSGO")
  field(LNK2, "MGNT:UNDS:2:ALLYCORSGO")
}

# In the PV MGNT:<LOCA>:2:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically, 
# MGNT_TYPE_XCOR equals 1 and is LNK1 
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:UNDS:2:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "OFFLINE")
  field(TWST, "ONLINE")
  field(THST, "DAC_ZERO")
  field(FRST, "RESET")
  field(FVST, "LOAD_IDES")
  field(ZRVL, "0")
  field(ONVL, "10")
  field(TWVL, "9")
  field(THVL, "7")
  field(FRVL, "8")
  field(FVVL, "12")
  field(FFVL, "2")
  field(FLNK, "MGNT:UNDS:2:XCORSWITCH")
}

record(seq, "MGNT:UNDS:2:XCORSWITCH") {
  field(DOL1, "MGNT:UNDS:2:XCORCTRL.FFVL")
  field(LNK1, "MGNT:UNDS:2:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDS:2:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDS:2:XCORCTRL")
}

record(seq, "MGNT:UNDS:2:ALLXCORSGO") {
  field(DOL1, "MGNT:UNDS:2:ALLSTAR")
  field(LNK1, "MGNT:UNDS:2:ALLXCORS PP NMS")
}

record(bo, "MGNT:UNDS:2:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDS:2:ALLXCORSSEL")
}

# End of file

# In the PV MGNT:<LOCA>:2:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically, 
# MGNT_TYPE_XCOR equals 1 and is LNK1 
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:UNDS:2:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "OFFLINE")
  field(TWST, "ONLINE")
  field(THST, "DAC_ZERO")
  field(FRST, "RESET")
  field(FVST, "LOAD_IDES")
  field(ZRVL, "0")
  field(ONVL, "10")
  field(TWVL, "9")
  field(THVL, "7")
  field(FRVL, "8")
  field(FVVL, "12")
  field(FFVL, "3")
  field(FLNK, "MGNT:UNDS:2:YCORSWITCH")
}

record(seq, "MGNT:UNDS:2:YCORSWITCH") {
  field(DOL1, "MGNT:UNDS:2:YCORCTRL.FFVL")
  field(LNK1, "MGNT:UNDS:2:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:UNDS:2:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:UNDS:2:YCORCTRL")
}

record(seq, "MGNT:UNDS:2:ALLYCORSGO") {
  field(DOL1, "MGNT:UNDS:2:ALLSTAR")
  field(LNK1, "MGNT:UNDS:2:ALLYCORS PP NMS")
}

record(bo, "MGNT:UNDS:2:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:UNDS:2:ALLYCORSSEL")
}

# End of file
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBDEND

record(seq, "MGNT:UNDH:1:ALLSOLNSSEL") {
}
record(seq, "MGNT:UNDH:1:ALLKICKSSEL") {
}
record(seq, "MGNT:UNDH:1:ALLSEXTSSEL") {
}

record(seq, "MGNT:UNDH:1:ALLBENDSSEL") {
  field(DOL1, "MGNT:UNDH:1:ALLBENDS")
  field(DOL2, "MGNT:UNDH:1:ALLBENDS")
  field(DOL3, "MGNT:UNDH:1:ALLBENDS")
  field(LNK1, "BEND:UNDH:1330:SELECT PP NMS")
  field(LNK2, "BEND:UNDH:2130:SELECT PP NMS")
  field(LNK3, "BEND:UNDH:2810:SELECT PP NMS")
}

record(seq, "MGNT:UNDH:1:ALLBTRMSSEL") {
  field(DOL1, "MGNT:UNDH:1:ALLBTRMS")
  field(DOL2, "MGNT:UNDH:1:ALLBTRMS")
  field(DOL3, "MGNT:UNDH:1:ALLBTRMS")
  field(DOL4, "MGNT:UNDH:1:ALLBTRMS")
  field(DOL5, "MGNT:UNDH:1:ALLBTRMS")
  field(DOL6, "MGNT:UNDH:1:ALLBTRMS")
  field(DOL7, "MGNT:UNDH:1:ALLBTRMS")
  field(DOL8, "MGNT:UNDH:1:ALLBTRMS")
  field(LNK1, "BTRM:UNDH:1330:SELECT PP NMS")
  field(LNK2, "BTRM:UNDH:1355:SELECT PP NMS")
  field(LNK3, "BTRM:UNDH:1360:SELECT PP NMS")
  field(LNK4, "BTRM:UNDH:1375:SELECT PP NMS")
  field(LNK5, "BTRM:UNDH:2130:SELECT PP NMS")
  field(LNK6, "BTRM:UNDH:2155:SELECT PP NMS")
  field(LNK7, "BTRM:UNDH:2160:SELECT PP NMS")
  field(LNK8, "BTRM:UNDH:2175:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:1:ALLBTRMSSEL1")
}
record(seq, "MGNT:UNDH:1:ALLBTRMSSEL1") {
  field(DOL1, "MGNT:UNDH:1:ALLBTRMS")
  field(DOL2, "MGNT:UNDH:1:ALLBTRMS")
  field(DOL3, "MGNT:UNDH:1:ALLBTRMS")
  field(DOL4, "MGNT:UNDH:1:ALLBTRMS")
  field(LNK1, "BTRM:UNDH:2810:SELECT PP NMS")
  field(LNK2, "BTRM:UNDH:2830:SELECT PP NMS")
  field(LNK3, "BTRM:UNDH:2850:SELECT PP NMS")
  field(LNK4, "BTRM:UNDH:2870:SELECT PP NMS")
}

record(seq, "MGNT:UNDH:1:ALLLGPSSSEL") {
  field(DOL1, "MGNT:UNDH:1:ALLLGPSS")
  field(DOL2, "MGNT:UNDH:1:ALLLGPSS")
  field(DOL3, "MGNT:UNDH:1:ALLLGPSS")
  field(DOL4, "MGNT:UNDH:1:ALLLGPSS")
  field(DOL5, "MGNT:UNDH:1:ALLLGPSS")
  field(DOL6, "MGNT:UNDH:1:ALLLGPSS")
  field(DOL7, "MGNT:UNDH:1:ALLLGPSS")
  field(DOL8, "MGNT:UNDH:1:ALLLGPSS")
  field(LNK1, "LGPS:UNDH:1:SELECT PP NMS")
  field(LNK2, "LGPS:UNDH:2:SELECT PP NMS")
  field(LNK3, "LGPS:UNDH:3:SELECT PP NMS")
  field(LNK4, "LGPS:UNDH:4:SELECT PP NMS")
  field(LNK5, "LGPS:UNDH:5:SELECT PP NMS")
  field(LNK6, "LGPS:UNDH:6:SELECT PP NMS")
  field(LNK7, "LGPS:UNDH:7:SELECT PP NMS")
  field(LNK8, "LGPS:UNDH:8:SELECT PP NMS")
}

record(seq, "MGNT:UNDH:1:ALLQUADSSEL") {
  field(DOL1, "MGNT:UNDH:1:ALLQUADS")
  field(DOL2, "MGNT:UNDH:1:ALLQUADS")
  field(DOL3, "MGNT:UNDH:1:ALLQUADS")
  field(DOL4, "MGNT:UNDH:1:ALLQUADS")
  field(DOL5, "MGNT:UNDH:1:ALLQUADS")
  field(DOL6, "MGNT:UNDH:1:ALLQUADS")
  field(LNK1, "QUAD:UNDH:1380:SELECT PP NMS")
  field(LNK2, "QUAD:UNDH:1480:SELECT PP NMS")
  field(LNK3, "QUAD:UNDH:1580:SELECT PP NMS")
  field(LNK4, "QUAD:UNDH:1680:SELECT PP NMS")
  field(LNK5, "QUAD:UNDH:1780:SELECT PP NMS")
  field(LNK6, "QUAD:UNDH:1880:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:1:ALLQUADSSEL1")
}

record(seq, "MGNT:UNDH:1:ALLQUADSSEL1") {
  field(DOL1, "MGNT:UNDH:1:ALLQUADS")
  field(DOL2, "MGNT:UNDH:1:ALLQUADS")
  field(DOL3, "MGNT:UNDH:1:ALLQUADS")
  field(DOL4, "MGNT:UNDH:1:ALLQUADS")
  field(DOL5, "MGNT:UNDH:1:ALLQUADS")
  field(DOL6, "MGNT:UNDH:1:ALLQUADS")
  field(DOL7, "MGNT:UNDH:1:ALLQUADS")
  field(DOL8, "MGNT:UNDH:1:ALLQUADS")
  field(DOL9, "MGNT:UNDH:1:ALLQUADS")
  field(DOLA, "MGNT:UNDH:1:ALLQUADS")
  field(LNK1, "QUAD:UNDH:1980:SELECT PP NMS")
  field(LNK2, "QUAD:UNDH:2080:SELECT PP NMS")
  field(LNK3, "QUAD:UNDH:2180:SELECT PP NMS")
  field(LNK4, "QUAD:UNDH:2280:SELECT PP NMS")
  field(LNK5, "QUAD:UNDH:2380:SELECT PP NMS")
  field(LNK6, "QUAD:UNDH:2480:SELECT PP NMS")
  field(LNK7, "QUAD:UNDH:2580:SELECT PP NMS")
  field(LNK8, "QUAD:UNDH:2680:SELECT PP NMS")
  field(LNK9, "QUAD:UNDH:2780:SELECT PP NMS")
  field(LNKA, "QUAD:UNDH:2880:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:1:ALLQUADSSEL2")
}

record(seq, "MGNT:UNDH:1:ALLQUADSSEL2") {
  field(DOL1, "MGNT:UNDH:1:ALLQUADS")
  field(DOL2, "MGNT:UNDH:1:ALLQUADS")
  field(DOL3, "MGNT:UNDH:1:ALLQUADS")
  field(DOL4, "MGNT:UNDH:1:ALLQUADS")
  field(DOL5, "MGNT:UNDH:1:ALLQUADS")
  field(DOL6, "MGNT:UNDH:1:ALLQUADS")
  field(DOL7, "MGNT:UNDH:1:ALLQUADS")
  field(DOL8, "MGNT:UNDH:1:ALLQUADS")
  field(DOL9, "MGNT:UNDH:1:ALLQUADS")
  field(DOLA, "MGNT:UNDH:1:ALLQUADS")
  field(LNK1, "QUAD:UNDH:2980:SELECT PP NMS")
  field(LNK2, "QUAD:UNDH:3080:SELECT PP NMS")
  field(LNK3, "QUAD:UNDH:3180:SELECT PP NMS")
  field(LNK4, "QUAD:UNDH:3280:SELECT PP NMS")
  field(LNK5, "QUAD:UNDH:3380:SELECT PP NMS")
  field(LNK6, "QUAD:UNDH:3480:SELECT PP NMS")
  field(LNK7, "QUAD:UNDH:3580:SELECT PP NMS")
  field(LNK8, "QUAD:UNDH:3680:SELECT PP NMS")
  field(LNK9, "QUAD:UNDH:3780:SELECT PP NMS")
  field(LNKA, "QUAD:UNDH:3880:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:1:ALLQUADSSEL3")
}

record(seq, "MGNT:UNDH:1:ALLQUADSSEL3") {
  field(DOL1, "MGNT:UNDH:1:ALLQUADS")
  field(DOL2, "MGNT:UNDH:1:ALLQUADS")
  field(DOL3, "MGNT:UNDH:1:ALLQUADS")
  field(DOL4, "MGNT:UNDH:1:ALLQUADS")
  field(DOL5, "MGNT:UNDH:1:ALLQUADS")
  field(DOL6, "MGNT:UNDH:1:ALLQUADS")
  field(DOL7, "MGNT:UNDH:1:ALLQUADS")
  field(DOL8, "MGNT:UNDH:1:ALLQUADS")
  field(DOL9, "MGNT:UNDH:1:ALLQUADS")
  field(LNK1, "QUAD:UNDH:3980:SELECT PP NMS")
  field(LNK2, "QUAD:UNDH:4080:SELECT PP NMS")
  field(LNK3, "QUAD:UNDH:4180:SELECT PP NMS")
  field(LNK4, "QUAD:UNDH:4280:SELECT PP NMS")
  field(LNK5, "QUAD:UNDH:4380:SELECT PP NMS")
  field(LNK6, "QUAD:UNDH:4480:SELECT PP NMS")
  field(LNK7, "QUAD:UNDH:4580:SELECT PP NMS")
  field(LNK8, "QUAD:UNDH:4680:SELECT PP NMS")
  field(LNK9, "QUAD:UNDH:4780:SELECT PP NMS")
}

record(seq, "MGNT:UNDH:1:ALLXCORSSEL") {
  field(DOL1, "MGNT:UNDH:1:ALLXCORS")
  field(DOL2, "MGNT:UNDH:1:ALLXCORS")
  field(DOL3, "MGNT:UNDH:1:ALLXCORS")
  field(DOL4, "MGNT:UNDH:1:ALLXCORS")
  field(DOL5, "MGNT:UNDH:1:ALLXCORS")
  field(DOL6, "MGNT:UNDH:1:ALLXCORS")
  field(LNK1, "XCOR:UNDH:1380:SELECT PP NMS")
  field(LNK2, "XCOR:UNDH:1480:SELECT PP NMS")
  field(LNK3, "XCOR:UNDH:1580:SELECT PP NMS")
  field(LNK4, "XCOR:UNDH:1680:SELECT PP NMS")
  field(LNK5, "XCOR:UNDH:1780:SELECT PP NMS")
  field(LNK6, "XCOR:UNDH:1880:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:1:ALLXCORSSEL1")
}

record(seq, "MGNT:UNDH:1:ALLXCORSSEL1") {
  field(DOL1, "MGNT:UNDH:1:ALLXCORS")
  field(DOL2, "MGNT:UNDH:1:ALLXCORS")
  field(DOL3, "MGNT:UNDH:1:ALLXCORS")
  field(DOL4, "MGNT:UNDH:1:ALLXCORS")
  field(DOL5, "MGNT:UNDH:1:ALLXCORS")
  field(DOL6, "MGNT:UNDH:1:ALLXCORS")
  field(DOL7, "MGNT:UNDH:1:ALLXCORS")
  field(DOL8, "MGNT:UNDH:1:ALLXCORS")
  field(DOL9, "MGNT:UNDH:1:ALLXCORS")
  field(DOLA, "MGNT:UNDH:1:ALLXCORS")
  field(LNK1, "XCOR:UNDH:1980:SELECT PP NMS")
  field(LNK2, "XCOR:UNDH:2080:SELECT PP NMS")
  field(LNK3, "XCOR:UNDH:2180:SELECT PP NMS")
  field(LNK4, "XCOR:UNDH:2280:SELECT PP NMS")
  field(LNK5, "XCOR:UNDH:2380:SELECT PP NMS")
  field(LNK6, "XCOR:UNDH:2480:SELECT PP NMS")
  field(LNK7, "XCOR:UNDH:2580:SELECT PP NMS")
  field(LNK8, "XCOR:UNDH:2680:SELECT PP NMS")
  field(LNK9, "XCOR:UNDH:2780:SELECT PP NMS")
  field(LNKA, "XCOR:UNDH:2880:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:1:ALLXCORSSEL2")
}

record(seq, "MGNT:UNDH:1:ALLXCORSSEL2") {
  field(DOL1, "MGNT:UNDH:1:ALLXCORS")
  field(DOL2, "MGNT:UNDH:1:ALLXCORS")
  field(DOL3, "MGNT:UNDH:1:ALLXCORS")
  field(DOL4, "MGNT:UNDH:1:ALLXCORS")
  field(DOL5, "MGNT:UNDH:1:ALLXCORS")
  field(DOL6, "MGNT:UNDH:1:ALLXCORS")
  field(DOL7, "MGNT:UNDH:1:ALLXCORS")
  field(DOL8, "MGNT:UNDH:1:ALLXCORS")
  field(DOL9, "MGNT:UNDH:1:ALLXCORS")
  field(DOLA, "MGNT:UNDH:1:ALLXCORS")
  field(LNK1, "XCOR:UNDH:2980:SELECT PP NMS")
  field(LNK2, "XCOR:UNDH:3080:SELECT PP NMS")
  field(LNK3, "XCOR:UNDH:3180:SELECT PP NMS")
  field(LNK4, "XCOR:UNDH:3280:SELECT PP NMS")
  field(LNK5, "XCOR:UNDH:3380:SELECT PP NMS")
  field(LNK6, "XCOR:UNDH:3480:SELECT PP NMS")
  field(LNK7, "XCOR:UNDH:3580:SELECT PP NMS")
  field(LNK8, "XCOR:UNDH:3680:SELECT PP NMS")
  field(LNK9, "XCOR:UNDH:3780:SELECT PP NMS")
  field(LNKA, "XCOR:UNDH:3880:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:1:ALLXCORSSEL3")
}

record(seq, "MGNT:UNDH:1:ALLXCORSSEL3") {
  field(DOL1, "MGNT:UNDH:1:ALLXCORS")
  field(DOL2, "MGNT:UNDH:1:ALLXCORS")
  field(DOL3, "MGNT:UNDH:1:ALLXCORS")
  field(DOL4, "MGNT:UNDH:1:ALLXCORS")
  field(DOL5, "MGNT:UNDH:1:ALLXCORS")
  field(DOL6, "MGNT:UNDH:1:ALLXCORS")
  field(DOL7, "MGNT:UNDH:1:ALLXCORS")
  field(DOL8, "MGNT:UNDH:1:ALLXCORS")
  field(DOL9, "MGNT:UNDH:1:ALLXCORS")
  field(LNK1, "XCOR:UNDH:3980:SELECT PP NMS")
  field(LNK2, "XCOR:UNDH:4080:SELECT PP NMS")
  field(LNK3, "XCOR:UNDH:4180:SELECT PP NMS")
  field(LNK4, "XCOR:UNDH:4280:SELECT PP NMS")
  field(LNK5, "XCOR:UNDH:4380:SELECT PP NMS")
  field(LNK6, "XCOR:UNDH:4480:SELECT PP NMS")
  field(LNK7, "XCOR:UNDH:4580:SELECT PP NMS")
  field(LNK8, "XCOR:UNDH:4680:SELECT PP NMS")
  field(LNK9, "XCOR:UNDH:4780:SELECT PP NMS")
}

record(seq, "MGNT:UNDH:1:ALLYCORSSEL") {
  field(DOL1, "MGNT:UNDH:1:ALLYCORS")
  field(DOL2, "MGNT:UNDH:1:ALLYCORS")
  field(DOL3, "MGNT:UNDH:1:ALLYCORS")
  field(DOL4, "MGNT:UNDH:1:ALLYCORS")
  field(DOL5, "MGNT:UNDH:1:ALLYCORS")
  field(DOL6, "MGNT:UNDH:1:ALLYCORS")
  field(LNK1, "YCOR:UNDH:1380:SELECT PP NMS")
  field(LNK2, "YCOR:UNDH:1480:SELECT PP NMS")
  field(LNK3, "YCOR:UNDH:1580:SELECT PP NMS")
  field(LNK4, "YCOR:UNDH:1680:SELECT PP NMS")
  field(LNK5, "YCOR:UNDH:1780:SELECT PP NMS")
  field(LNK6, "YCOR:UNDH:1880:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:1:ALLYCORSSEL1")
}

record(seq, "MGNT:UNDH:1:ALLYCORSSEL1") {
  field(DOL1, "MGNT:UNDH:1:ALLYCORS")
  field(DOL2, "MGNT:UNDH:1:ALLYCORS")
  field(DOL3, "MGNT:UNDH:1:ALLYCORS")
  field(DOL4, "MGNT:UNDH:1:ALLYCORS")
  field(DOL5, "MGNT:UNDH:1:ALLYCORS")
  field(DOL6, "MGNT:UNDH:1:ALLYCORS")
  field(DOL7, "MGNT:UNDH:1:ALLYCORS")
  field(DOL8, "MGNT:UNDH:1:ALLYCORS")
  field(DOL9, "MGNT:UNDH:1:ALLYCORS")
  field(DOLA, "MGNT:UNDH:1:ALLYCORS")
  field(LNK1, "YCOR:UNDH:1980:SELECT PP NMS")
  field(LNK2, "YCOR:UNDH:2080:SELECT PP NMS")
  field(LNK3, "YCOR:UNDH:2180:SELECT PP NMS")
  field(LNK4, "YCOR:UNDH:2280:SELECT PP NMS")
  field(LNK5, "YCOR:UNDH:2380:SELECT PP NMS")
  field(LNK6, "YCOR:UNDH:2480:SELECT PP NMS")
  field(LNK7, "YCOR:UNDH:2580:SELECT PP NMS")
  field(LNK8, "YCOR:UNDH:2680:SELECT PP NMS")
  field(LNK9, "YCOR:UNDH:2780:SELECT PP NMS")
  field(LNKA, "YCOR:UNDH:2880:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:1:ALLYCORSSEL2")
}

record(seq, "MGNT:UNDH:1:ALLYCORSSEL2") {
  field(DOL1, "MGNT:UNDH:1:ALLYCORS")
  field(DOL2, "MGNT:UNDH:1:ALLYCORS")
  field(DOL3, "MGNT:UNDH:1:ALLYCORS")
  field(DOL4, "MGNT:UNDH:1:ALLYCORS")
  field(DOL5, "MGNT:UNDH:1:ALLYCORS")
  field(DOL6, "MGNT:UNDH:1:ALLYCORS")
  field(DOL7, "MGNT:UNDH:1:ALLYCORS")
  field(DOL8, "MGNT:UNDH:1:ALLYCORS")
  field(DOL9, "MGNT:UNDH:1:ALLYCORS")
  field(DOLA, "MGNT:UNDH:1:ALLYCORS")
  field(LNK1, "YCOR:UNDH:2980:SELECT PP NMS")
  field(LNK2, "YCOR:UNDH:3080:SELECT PP NMS")
  field(LNK3, "YCOR:UNDH:3180:SELECT PP NMS")
  field(LNK4, "YCOR:UNDH:3280:SELECT PP NMS")
  field(LNK5, "YCOR:UNDH:3380:SELECT PP NMS")
  field(LNK6, "YCOR:UNDH:3480:SELECT PP NMS")
  field(LNK7, "YCOR:UNDH:3580:SELECT PP NMS")
  field(LNK8, "YCOR:UNDH:3680:SELECT PP NMS")
  field(LNK9, "YCOR:UNDH:3780:SELECT PP NMS")
  field(LNKA, "YCOR:UNDH:3880:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:1:ALLYCORSSEL3")
}

record(seq, "MGNT:UNDH:1:ALLYCORSSEL3") {
  field(DOL1, "MGNT:UNDH:1:ALLYCORS")
  field(DOL2, "MGNT:UNDH:1:ALLYCORS")
  field(DOL3, "MGNT:UNDH:1:ALLYCORS")
  field(DOL4, "MGNT:UNDH:1:ALLYCORS")
  field(DOL5, "MGNT:UNDH:1:ALLYCORS")
  field(DOL6, "MGNT:UNDH:1:ALLYCORS")
  field(DOL7, "MGNT:UNDH:1:ALLYCORS")
  field(DOL8, "MGNT:UNDH:1:ALLYCORS")
  field(DOL9, "MGNT:UNDH:1:ALLYCORS")
  field(LNK1, "YCOR:UNDH:3980:SELECT PP NMS")
  field(LNK2, "YCOR:UNDH:4080:SELECT PP NMS")
  field(LNK3, "YCOR:UNDH:4180:SELECT PP NMS")
  field(LNK4, "YCOR:UNDH:4280:SELECT PP NMS")
  field(LNK5, "YCOR:UNDH:4380:SELECT PP NMS")
  field(LNK6, "YCOR:UNDH:4480:SELECT PP NMS")
  field(LNK7, "YCOR:UNDH:4580:SELECT PP NMS")
  field(LNK8, "YCOR:UNDH:4680:SELECT PP NMS")
  field(LNK9, "YCOR:UNDH:4780:SELECT PP NMS")
}

record(seq, "MGNT:UNDH:1:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(DOL8, "1")
  field(LNK1, "MGNT:UNDH:1:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:UNDH:1:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:UNDH:1:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:UNDH:1:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:UNDH:1:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:UNDH:1:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:UNDH:1:LGPSFUNCGO.PROC")
  field(LNK8, "MGNT:UNDH:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:UNDH:1:CTRLCLEAR")
}

record(fanout, "MGNT:UNDH:1:SOLNFUNCGO") {
  field(DESC, "Process SOLN CTRL func")
  field(FLNK, "MGNT:UNDH:1:CTRLCLEAR")
}
record(fanout, "MGNT:UNDH:1:KICKFUNCGO") {
  field(DESC, "Process KICK CTRL func")
  field(FLNK, "MGNT:UNDH:1:CTRLCLEAR")
}
record(fanout, "MGNT:UNDH:1:SEXTFUNCGO") {
  field(DESC, "Process SEXT CTRL func")
  field(FLNK, "MGNT:UNDH:1:CTRLCLEAR")
}

record(fanout, "MGNT:UNDH:1:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(LNK1, "BEND:UNDH:1330:ALLFUNCGO")
  field(LNK2, "BEND:UNDH:2130:ALLFUNCGO")
  field(LNK3, "BEND:UNDH:2810:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:CTRLCLEAR")
}

record(fanout, "MGNT:UNDH:1:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(LNK1, "BTRM:UNDH:1330:ALLFUNCGO")
  field(LNK2, "BTRM:UNDH:1355:ALLFUNCGO")
  field(LNK3, "BTRM:UNDH:1360:ALLFUNCGO")
  field(LNK4, "BTRM:UNDH:1375:ALLFUNCGO")
  field(LNK5, "BTRM:UNDH:2130:ALLFUNCGO")
  field(LNK6, "BTRM:UNDH:2155:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:BTRMFUNCGO1")
}
record(fanout, "MGNT:UNDH:1:BTRMFUNCGO1") {
  field(DESC, "Process BTRM CTRL func")
  field(LNK1, "BTRM:UNDH:2160:ALLFUNCGO")
  field(LNK2, "BTRM:UNDH:2175:ALLFUNCGO")
  field(LNK3, "BTRM:UNDH:2810:ALLFUNCGO")
  field(LNK4, "BTRM:UNDH:2830:ALLFUNCGO")
  field(LNK5, "BTRM:UNDH:2850:ALLFUNCGO")
  field(LNK6, "BTRM:UNDH:2870:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:CTRLCLEAR")
}

record(fanout, "MGNT:UNDH:1:LGPSFUNCGO") {
  field(DESC, "Process LGPS CTRL func")
  field(LNK1, "LGPS:UNDH:1:ALLFUNCGO")
  field(LNK2, "LGPS:UNDH:2:ALLFUNCGO")
  field(LNK3, "LGPS:UNDH:3:ALLFUNCGO")
  field(LNK4, "LGPS:UNDH:4:ALLFUNCGO")
  field(LNK5, "LGPS:UNDH:5:ALLFUNCGO")
  field(LNK6, "LGPS:UNDH:6:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:LCLSFUNCGO1")
}

record(fanout, "MGNT:UNDH:1:LCLSFUNCGO1") {
  field(DESC, "Process LGPS CTRL func")
  field(LNK1, "LGPS:UNDH:7:ALLFUNCGO")
  field(LNK2, "LGPS:UNDH:8:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:CTRLCLEAR")
}

record(fanout, "MGNT:UNDH:1:QUADFUNCGO") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:UNDH:1380:ALLFUNCGO")
  field(LNK2, "QUAD:UNDH:1480:ALLFUNCGO")
  field(LNK3, "QUAD:UNDH:1580:ALLFUNCGO")
  field(LNK4, "QUAD:UNDH:1680:ALLFUNCGO")
  field(LNK5, "QUAD:UNDH:1780:ALLFUNCGO")
  field(LNK6, "QUAD:UNDH:1880:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:QUADFUNCGO1")
}

record(fanout, "MGNT:UNDH:1:QUADFUNCGO1") {
  field(LNK1, "QUAD:UNDH:1980:ALLFUNCGO")
  field(LNK2, "QUAD:UNDH:2080:ALLFUNCGO")
  field(LNK3, "QUAD:UNDH:2180:ALLFUNCGO")
  field(LNK4, "QUAD:UNDH:2280:ALLFUNCGO")
  field(LNK5, "QUAD:UNDH:2380:ALLFUNCGO")
  field(LNK6, "QUAD:UNDH:2480:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:QUADFUNCGO2")
}

record(fanout, "MGNT:UNDH:1:QUADFUNCGO2") {
  field(LNK1, "QUAD:UNDH:2580:ALLFUNCGO")
  field(LNK2, "QUAD:UNDH:2680:ALLFUNCGO")
  field(LNK3, "QUAD:UNDH:2780:ALLFUNCGO")
  field(LNK4, "QUAD:UNDH:2880:ALLFUNCGO")
  field(LNK5, "QUAD:UNDH:2980:ALLFUNCGO")
  field(LNK6, "QUAD:UNDH:3080:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:QUADFUNCGO3")
}

record(fanout, "MGNT:UNDH:1:QUADFUNCGO3") {
  field(LNK1, "QUAD:UNDH:3180:ALLFUNCGO")
  field(LNK2, "QUAD:UNDH:3280:ALLFUNCGO")
  field(LNK3, "QUAD:UNDH:3380:ALLFUNCGO")
  field(LNK4, "QUAD:UNDH:3480:ALLFUNCGO")
  field(LNK5, "QUAD:UNDH:3580:ALLFUNCGO")
  field(LNK6, "QUAD:UNDH:3680:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:QUADFUNCGO4")
}

record(fanout, "MGNT:UNDH:1:QUADFUNCGO4") {
  field(LNK1, "QUAD:UNDH:3780:ALLFUNCGO")
  field(LNK2, "QUAD:UNDH:3880:ALLFUNCGO")
  field(LNK3, "QUAD:UNDH:3980:ALLFUNCGO")
  field(LNK4, "QUAD:UNDH:4080:ALLFUNCGO")
  field(LNK5, "QUAD:UNDH:4180:ALLFUNCGO")
  field(LNK6, "QUAD:UNDH:4280:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:QUADFUNCGO5")
}

record(fanout, "MGNT:UNDH:1:QUADFUNCGO5") {
  field(LNK1, "QUAD:UNDH:4380:ALLFUNCGO")
  field(LNK2, "QUAD:UNDH:4480:ALLFUNCGO")
  field(LNK3, "QUAD:UNDH:4580:ALLFUNCGO")
  field(LNK4, "QUAD:UNDH:4680:ALLFUNCGO")
  field(LNK5, "QUAD:UNDH:4780:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:CTRLCLEAR")
}

record(fanout, "MGNT:UNDH:1:XCORFUNCGO") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:UNDH:1380:ALLFUNCGO")
  field(LNK2, "XCOR:UNDH:1480:ALLFUNCGO")
  field(LNK3, "XCOR:UNDH:1580:ALLFUNCGO")
  field(LNK4, "XCOR:UNDH:1680:ALLFUNCGO")
  field(LNK5, "XCOR:UNDH:1780:ALLFUNCGO")
  field(LNK6, "XCOR:UNDH:1880:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:XCORFUNCGO1")
}

record (fanout, "MGNT:UNDH:1:XCORFUNCGO1") {
  field(LNK1, "XCOR:UNDH:1980:ALLFUNCGO")
  field(LNK2, "XCOR:UNDH:2080:ALLFUNCGO")
  field(LNK3, "XCOR:UNDH:2180:ALLFUNCGO")
  field(LNK4, "XCOR:UNDH:2280:ALLFUNCGO")
  field(LNK5, "XCOR:UNDH:2380:ALLFUNCGO")
  field(LNK6, "XCOR:UNDH:2480:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:XCORFUNCGO2")
}

record (fanout, "MGNT:UNDH:1:XCORFUNCGO2") {
  field(LNK1, "XCOR:UNDH:2580:ALLFUNCGO")
  field(LNK2, "XCOR:UNDH:2680:ALLFUNCGO")
  field(LNK3, "XCOR:UNDH:2780:ALLFUNCGO")
  field(LNK4, "XCOR:UNDH:2880:ALLFUNCGO")
  field(LNK5, "XCOR:UNDH:2980:ALLFUNCGO")
  field(LNK6, "XCOR:UNDH:3080:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:XCORFUNCGO3")
}

record (fanout, "MGNT:UNDH:1:XCORFUNCGO3") {
  field(LNK1, "XCOR:UNDH:3180:ALLFUNCGO")
  field(LNK2, "XCOR:UNDH:3280:ALLFUNCGO")
  field(LNK3, "XCOR:UNDH:3380:ALLFUNCGO")
  field(LNK4, "XCOR:UNDH:3480:ALLFUNCGO")
  field(LNK5, "XCOR:UNDH:3580:ALLFUNCGO")
  field(LNK6, "XCOR:UNDH:3680:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:XCORFUNCGO4")
}

record (fanout, "MGNT:UNDH:1:XCORFUNCGO4") {
  field(LNK1, "XCOR:UNDH:3780:ALLFUNCGO")
  field(LNK2, "XCOR:UNDH:3880:ALLFUNCGO")
  field(LNK3, "XCOR:UNDH:3980:ALLFUNCGO")
  field(LNK4, "XCOR:UNDH:4080:ALLFUNCGO")
  field(LNK5, "XCOR:UNDH:4180:ALLFUNCGO")
  field(LNK6, "XCOR:UNDH:4280:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:XCORFUNCGO5")
}

record (fanout, "MGNT:UNDH:1:XCORFUNCGO5") {
  field(LNK1, "XCOR:UNDH:4380:ALLFUNCGO")
  field(LNK2, "XCOR:UNDH:4480:ALLFUNCGO")
  field(LNK3, "XCOR:UNDH:4580:ALLFUNCGO")
  field(LNK4, "XCOR:UNDH:4680:ALLFUNCGO")
  field(LNK5, "XCOR:UNDH:4780:ALLFUNCGO")
  field (FLNK, "MGNT:UNDH:1:CTRLCLEAR")
}

record(fanout, "MGNT:UNDH:1:YCORFUNCGO") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:UNDH:1380:ALLFUNCGO")
  field(LNK2, "YCOR:UNDH:1480:ALLFUNCGO")
  field(LNK3, "YCOR:UNDH:1580:ALLFUNCGO")
  field(LNK4, "YCOR:UNDH:1680:ALLFUNCGO")
  field(LNK5, "YCOR:UNDH:1780:ALLFUNCGO")
  field(LNK6, "YCOR:UNDH:1880:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:YCORFUNCGO1")
}

record (fanout, "MGNT:UNDH:1:YCORFUNCGO1") {
  field(LNK1, "YCOR:UNDH:1980:ALLFUNCGO")
  field(LNK2, "YCOR:UNDH:2080:ALLFUNCGO")
  field(LNK3, "YCOR:UNDH:2180:ALLFUNCGO")
  field(LNK4, "YCOR:UNDH:2280:ALLFUNCGO")
  field(LNK5, "YCOR:UNDH:2380:ALLFUNCGO")
  field(LNK6, "YCOR:UNDH:2480:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:YCORFUNCGO2")
}

record (fanout, "MGNT:UNDH:1:YCORFUNCGO2") {
  field(LNK1, "YCOR:UNDH:2580:ALLFUNCGO")
  field(LNK2, "YCOR:UNDH:2680:ALLFUNCGO")
  field(LNK3, "YCOR:UNDH:2780:ALLFUNCGO")
  field(LNK4, "YCOR:UNDH:2880:ALLFUNCGO")
  field(LNK5, "YCOR:UNDH:2980:ALLFUNCGO")
  field(LNK6, "YCOR:UNDH:3080:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:YCORFUNCGO3")
}

record (fanout, "MGNT:UNDH:1:YCORFUNCGO3") {
  field(LNK1, "YCOR:UNDH:3180:ALLFUNCGO")
  field(LNK2, "YCOR:UNDH:3280:ALLFUNCGO")
  field(LNK3, "YCOR:UNDH:3380:ALLFUNCGO")
  field(LNK4, "YCOR:UNDH:3480:ALLFUNCGO")
  field(LNK5, "YCOR:UNDH:3580:ALLFUNCGO")
  field(LNK6, "YCOR:UNDH:3680:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:YCORFUNCGO4")
}

record (fanout, "MGNT:UNDH:1:YCORFUNCGO4") {
  field(LNK1, "YCOR:UNDH:3780:ALLFUNCGO")
  field(LNK2, "YCOR:UNDH:3880:ALLFUNCGO")
  field(LNK3, "YCOR:UNDH:3980:ALLFUNCGO")
  field(LNK4, "YCOR:UNDH:4080:ALLFUNCGO")
  field(LNK5, "YCOR:UNDH:4180:ALLFUNCGO")
  field(LNK6, "YCOR:UNDH:4280:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:YCORFUNCGO5")
}

record (fanout, "MGNT:UNDH:1:YCORFUNCGO5") {
  field(LNK1, "YCOR:UNDH:4380:ALLFUNCGO")
  field(LNK2, "YCOR:UNDH:4480:ALLFUNCGO")
  field(LNK3, "YCOR:UNDH:4580:ALLFUNCGO")
  field(LNK4, "YCOR:UNDH:4680:ALLFUNCGO")
  field(LNK5, "YCOR:UNDH:4780:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:1:CTRLCLEAR")
}

# End of file
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBDEND


record(seq, "MGNT:UNDS:1:ALLSOLNSSEL") {
}
record(seq, "MGNT:UNDS:1:ALLKICKSSEL") {
}
record(seq, "MGNT:UNDS:1:ALLSEXTSSEL") {
}

record(seq, "MGNT:UNDS:1:ALLBENDSSEL") {
  field(DOL1, "MGNT:UNDS:1:ALLBENDS")
  field(LNK1, "BEND:UNDS:3510:SELECT PP NMS")
}

record(seq, "MGNT:UNDS:1:ALLBTRMSSEL") {
  field(DOL1, "MGNT:UNDS:1:ALLBTRMS")
  field(DOL2, "MGNT:UNDS:1:ALLBTRMS")
  field(DOL3, "MGNT:UNDS:1:ALLBTRMS")
  field(DOL4, "MGNT:UNDS:1:ALLBTRMS")
  field(LNK1, "BTRM:UNDS:3510:SELECT PP NMS")
  field(LNK2, "BTRM:UNDS:3530:SELECT PP NMS")
  field(LNK3, "BTRM:UNDS:3550:SELECT PP NMS")
  field(LNK4, "BTRM:UNDS:3570:SELECT PP NMS")
}

record(seq, "MGNT:UNDS:1:ALLLGPSSSEL") {
  field(DOL1, "MGNT:UNDS:1:ALLLGPSS")
  field(LNK1, "LGPS:UNDS:1:SELECT PP NMS")
  field(LNK2, "LGPS:UNDS:2:SELECT PP NMS")
}

record(seq, "MGNT:UNDS:1:ALLQUADSSEL") {
  field(DOL1, "MGNT:UNDS:1:ALLQUADS")
  field(DOL1, "MGNT:UNDS:1:ALLQUADS")
  field(DOL2, "MGNT:UNDS:1:ALLQUADS")
  field(DOL3, "MGNT:UNDS:1:ALLQUADS")
  field(DOL4, "MGNT:UNDS:1:ALLQUADS")
  field(DOL5, "MGNT:UNDS:1:ALLQUADS")
  field(DOL6, "MGNT:UNDS:1:ALLQUADS")
  field(DOL7, "MGNT:UNDS:1:ALLQUADS")
  field(DOL8, "MGNT:UNDS:1:ALLQUADS")
  field(DOL9, "MGNT:UNDS:1:ALLQUADS")
  field(DOLA, "MGNT:UNDS:1:ALLQUADS")
  field(LNK1, "QUAD:UNDS:1680:SELECT PP NMS")
  field(LNK2, "QUAD:UNDS:1980:SELECT PP NMS")
  field(LNK3, "QUAD:UNDS:2180:SELECT PP NMS")
  field(LNK4, "QUAD:UNDS:2480:SELECT PP NMS")
  field(LNK5, "QUAD:UNDS:2680:SELECT PP NMS")
  field(LNK6, "QUAD:UNDS:2780:SELECT PP NMS")
  field(LNK7, "QUAD:UNDS:2880:SELECT PP NMS")
  field(LNK8, "QUAD:UNDS:2980:SELECT PP NMS")
  field(LNK9, "QUAD:UNDS:3080:SELECT PP NMS")
  field(LNKA, "QUAD:UNDS:3180:SELECT PP NMS")
  field(FLNK, "MGNT:UNDS:1:ALLQUADSSEL1")
}

record(seq, "MGNT:UNDS:1:ALLQUADSSEL1") {
  field(DOL1, "MGNT:UNDS:1:ALLQUADS")
  field(DOL2, "MGNT:UNDS:1:ALLQUADS")
  field(DOL3, "MGNT:UNDS:1:ALLQUADS")
  field(DOL4, "MGNT:UNDS:1:ALLQUADS")
  field(DOL5, "MGNT:UNDS:1:ALLQUADS")
  field(DOL6, "MGNT:UNDS:1:ALLQUADS")
  field(DOL7, "MGNT:UNDS:1:ALLQUADS")
  field(DOL8, "MGNT:UNDS:1:ALLQUADS")
  field(DOL9, "MGNT:UNDS:1:ALLQUADS")
  field(DOLA, "MGNT:UNDS:1:ALLQUADS")
  field(LNK1, "QUAD:UNDS:3280:SELECT PP NMS")
  field(LNK2, "QUAD:UNDS:3380:SELECT PP NMS")
  field(LNK3, "QUAD:UNDS:3480:SELECT PP NMS")
  field(LNK4, "QUAD:UNDS:3580:SELECT PP NMS")
  field(LNK5, "QUAD:UNDS:3680:SELECT PP NMS")
  field(LNK6, "QUAD:UNDS:3780:SELECT PP NMS")
  field(LNK7, "QUAD:UNDS:3880:SELECT PP NMS")
  field(LNK8, "QUAD:UNDS:3980:SELECT PP NMS")
  field(LNK9, "QUAD:UNDS:4080:SELECT PP NMS")
  field(LNKA, "QUAD:UNDS:4180:SELECT PP NMS")
  field(FLNK, "MGNT:UNDS:1:ALLQUADSSEL2")
}

record(seq, "MGNT:UNDS:1:ALLQUADSSEL2") {
  field(DOL1, "MGNT:UNDS:1:ALLQUADS")
  field(DOL2, "MGNT:UNDS:1:ALLQUADS")
  field(DOL3, "MGNT:UNDS:1:ALLQUADS")
  field(DOL4, "MGNT:UNDS:1:ALLQUADS")
  field(DOL5, "MGNT:UNDS:1:ALLQUADS")
  field(DOL6, "MGNT:UNDS:1:ALLQUADS")
  field(LNK1, "QUAD:UNDS:4280:SELECT PP NMS")
  field(LNK2, "QUAD:UNDS:4380:SELECT PP NMS")
  field(LNK3, "QUAD:UNDS:4480:SELECT PP NMS")
  field(LNK4, "QUAD:UNDS:4580:SELECT PP NMS")
  field(LNK5, "QUAD:UNDS:4680:SELECT PP NMS")
  field(LNK6, "QUAD:UNDS:4780:SELECT PP NMS")
}

record(seq, "MGNT:UNDS:1:ALLXCORSSEL") {
  field(DOL1, "MGNT:UNDS:1:ALLXCORS")
  field(DOL2, "MGNT:UNDS:1:ALLXCORS")
  field(DOL3, "MGNT:UNDS:1:ALLXCORS")
  field(DOL4, "MGNT:UNDS:1:ALLXCORS")
  field(DOL5, "MGNT:UNDS:1:ALLXCORS")
  field(DOL6, "MGNT:UNDS:1:ALLXCORS")
  field(DOL7, "MGNT:UNDS:1:ALLXCORS")
  field(DOL8, "MGNT:UNDS:1:ALLXCORS")
  field(DOL9, "MGNT:UNDS:1:ALLXCORS")
  field(DOLA, "MGNT:UNDS:1:ALLXCORS")
  field(LNK1, "XCOR:UNDS:1680:SELECT PP NMS")
  field(LNK2, "XCOR:UNDS:1980:SELECT PP NMS")
  field(LNK3, "XCOR:UNDS:2180:SELECT PP NMS")
  field(LNK4, "XCOR:UNDS:2480:SELECT PP NMS")
  field(LNK5, "XCOR:UNDS:2680:SELECT PP NMS")
  field(LNK6, "XCOR:UNDS:2780:SELECT PP NMS")
  field(LNK7, "XCOR:UNDS:2880:SELECT PP NMS")
  field(LNK8, "XCOR:UNDS:2980:SELECT PP NMS")
  field(LNK9, "XCOR:UNDS:3080:SELECT PP NMS")
  field(LNKA, "XCOR:UNDS:3180:SELECT PP NMS")
  field(FLNK, "MGNT:UNDS:1:ALLXCORSSEL1")
}

record(seq, "MGNT:UNDS:1:ALLXCORSSEL1") {
  field(DOL1, "MGNT:UNDS:1:ALLXCORS")
  field(DOL2, "MGNT:UNDS:1:ALLXCORS")
  field(DOL3, "MGNT:UNDS:1:ALLXCORS")
  field(DOL4, "MGNT:UNDS:1:ALLXCORS")
  field(DOL5, "MGNT:UNDS:1:ALLXCORS")
  field(DOL6, "MGNT:UNDS:1:ALLXCORS")
  field(DOL7, "MGNT:UNDS:1:ALLXCORS")
  field(DOL8, "MGNT:UNDS:1:ALLXCORS")
  field(DOL9, "MGNT:UNDS:1:ALLXCORS")
  field(DOLA, "MGNT:UNDS:1:ALLXCORS")
  field(LNK1, "XCOR:UNDS:3280:SELECT PP NMS")
  field(LNK2, "XCOR:UNDS:3380:SELECT PP NMS")
  field(LNK3, "XCOR:UNDS:3480:SELECT PP NMS")
  field(LNK4, "XCOR:UNDS:3580:SELECT PP NMS")
  field(LNK5, "XCOR:UNDS:3680:SELECT PP NMS")
  field(LNK6, "XCOR:UNDS:3780:SELECT PP NMS")
  field(LNK7, "XCOR:UNDS:3880:SELECT PP NMS")
  field(LNK8, "XCOR:UNDS:3980:SELECT PP NMS")
  field(LNK9, "XCOR:UNDS:4080:SELECT PP NMS")
  field(LNKA, "XCOR:UNDS:4180:SELECT PP NMS")
  field(FLNK, "MGNT:UNDS:1:ALLXCORSSEL2")
}

record(seq, "MGNT:UNDS:1:ALLXCORSSEL2") {
  field(DOL1, "MGNT:UNDS:1:ALLXCORS")
  field(DOL2, "MGNT:UNDS:1:ALLXCORS")
  field(DOL3, "MGNT:UNDS:1:ALLXCORS")
  field(DOL4, "MGNT:UNDS:1:ALLXCORS")
  field(DOL5, "MGNT:UNDS:1:ALLXCORS")
  field(DOL6, "MGNT:UNDS:1:ALLXCORS")
  field(DOL7, "MGNT:UNDS:1:ALLXCORS")
  field(DOL8, "MGNT:UNDS:1:ALLXCORS")
  field(LNK1, "XCOR:UNDS:4280:SELECT PP NMS")
  field(LNK2, "XCOR:UNDS:4380:SELECT PP NMS")
  field(LNK3, "XCOR:UNDS:4480:SELECT PP NMS")
  field(LNK4, "XCOR:UNDS:4580:SELECT PP NMS")
  field(LNK5, "XCOR:UNDS:4680:SELECT PP NMS")
  field(LNK6, "XCOR:UNDS:4780:SELECT PP NMS")
  field(LNK7, "XCOR:UNDS:4982:SELECT PP NMS")
  field(LNK8, "XCOR:UNDS:5038:SELECT PP NMS")
}

record(seq, "MGNT:UNDS:1:ALLYCORSSEL") {
  field(DOL1, "MGNT:UNDS:1:ALLYCORS")
  field(DOL2, "MGNT:UNDS:1:ALLYCORS")
  field(DOL3, "MGNT:UNDS:1:ALLYCORS")
  field(DOL4, "MGNT:UNDS:1:ALLYCORS")
  field(DOL5, "MGNT:UNDS:1:ALLYCORS")
  field(DOL6, "MGNT:UNDS:1:ALLYCORS")
  field(DOL7, "MGNT:UNDS:1:ALLYCORS")
  field(DOL8, "MGNT:UNDS:1:ALLYCORS")
  field(DOL9, "MGNT:UNDS:1:ALLYCORS")
  field(DOLA, "MGNT:UNDS:1:ALLYCORS")
  field(LNK1, "YCOR:UNDS:1680:SELECT PP NMS")
  field(LNK2, "YCOR:UNDS:1980:SELECT PP NMS")
  field(LNK3, "YCOR:UNDS:2180:SELECT PP NMS")
  field(LNK4, "YCOR:UNDS:2480:SELECT PP NMS")
  field(LNK5, "YCOR:UNDS:2680:SELECT PP NMS")
  field(LNK6, "YCOR:UNDS:2780:SELECT PP NMS")
  field(LNK7, "YCOR:UNDS:2880:SELECT PP NMS")
  field(LNK8, "YCOR:UNDS:2980:SELECT PP NMS")
  field(LNK9, "YCOR:UNDS:3080:SELECT PP NMS")
  field(LNKA, "YCOR:UNDS:3180:SELECT PP NMS")
  field(FLNK, "MGNT:UNDS:1:ALLYCORSSEL1")
}

record(seq, "MGNT:UNDS:1:ALLYCORSSEL1") {
  field(DOL1, "MGNT:UNDS:1:ALLYCORS")
  field(DOL2, "MGNT:UNDS:1:ALLYCORS")
  field(DOL3, "MGNT:UNDS:1:ALLYCORS")
  field(DOL4, "MGNT:UNDS:1:ALLYCORS")
  field(DOL5, "MGNT:UNDS:1:ALLYCORS")
  field(DOL6, "MGNT:UNDS:1:ALLYCORS")
  field(DOL7, "MGNT:UNDS:1:ALLYCORS")
  field(DOL8, "MGNT:UNDS:1:ALLYCORS")
  field(DOL9, "MGNT:UNDS:1:ALLYCORS")
  field(DOLA, "MGNT:UNDS:1:ALLYCORS")
  field(LNK1, "YCOR:UNDS:3280:SELECT PP NMS")
  field(LNK2, "YCOR:UNDS:3380:SELECT PP NMS")
  field(LNK3, "YCOR:UNDS:3480:SELECT PP NMS")
  field(LNK4, "YCOR:UNDS:3580:SELECT PP NMS")
  field(LNK5, "YCOR:UNDS:3680:SELECT PP NMS")
  field(LNK6, "YCOR:UNDS:3780:SELECT PP NMS")
  field(LNK7, "YCOR:UNDS:3880:SELECT PP NMS")
  field(LNK8, "YCOR:UNDS:3980:SELECT PP NMS")
  field(LNK9, "YCOR:UNDS:4080:SELECT PP NMS")
  field(LNKA, "YCOR:UNDS:4180:SELECT PP NMS")
  field(FLNK, "MGNT:UNDS:1:ALLYCORSSEL2")
}

record(seq, "MGNT:UNDS:1:ALLYCORSSEL2") {
  field(DOL1, "MGNT:UNDS:1:ALLYCORS")
  field(DOL2, "MGNT:UNDS:1:ALLYCORS")
  field(DOL3, "MGNT:UNDS:1:ALLYCORS")
  field(DOL4, "MGNT:UNDS:1:ALLYCORS")
  field(DOL5, "MGNT:UNDS:1:ALLYCORS")
  field(DOL6, "MGNT:UNDS:1:ALLYCORS")
  field(LNK1, "YCOR:UNDS:4280:SELECT PP NMS")
  field(LNK2, "YCOR:UNDS:4380:SELECT PP NMS")
  field(LNK3, "YCOR:UNDS:4480:SELECT PP NMS")
  field(LNK4, "YCOR:UNDS:4580:SELECT PP NMS")
  field(LNK5, "YCOR:UNDS:4680:SELECT PP NMS")
  field(LNK6, "YCOR:UNDS:4780:SELECT PP NMS")
}

record(seq, "MGNT:UNDS:1:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(DOL8, "1")
  field(LNK1, "MGNT:UNDS:1:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:UNDS:1:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:UNDS:1:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:UNDS:1:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:UNDS:1:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:UNDS:1:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:UNDS:1:LGPSFUNCGO.PROC")
  field(LNK8, "MGNT:UNDS:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:UNDS:1:CTRLCLEAR")
}

record(fanout, "MGNT:UNDS:1:SOLNFUNCGO") {
  field(DESC, "Process SOLN CTRL func")
  field(FLNK, "MGNT:UNDS:1:CTRLCLEAR")
}
record(fanout, "MGNT:UNDS:1:KICKFUNCGO") {
  field(DESC, "Process KICK CTRL func")
  field(FLNK, "MGNT:UNDS:1:CTRLCLEAR")
}
record(fanout, "MGNT:UNDS:1:SEXTFUNCGO") {
  field(DESC, "Process SEXT CTRL func")
  field(FLNK, "MGNT:UNDS:1:CTRLCLEAR")
}

record(fanout, "MGNT:UNDS:1:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(LNK1, "BEND:UNDS:3510:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:CTRLCLEAR")
}

record(fanout, "MGNT:UNDS:1:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(LNK1, "BTRM:UNDS:3510:ALLFUNCGO")
  field(LNK2, "BTRM:UNDS:3530:ALLFUNCGO")
  field(LNK3, "BTRM:UNDS:3550:ALLFUNCGO")
  field(LNK4, "BTRM:UNDS:3570:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:CTRLCLEAR")
}

record(fanout, "MGNT:UNDS:1:LGPSFUNCGO") {
  field(DESC, "Process LGPS CTRL func")
  field(LNK1, "LGPS:UNDS:1:ALLFUNCGO")
  field(LNK2, "LGPS:UNDS:2:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:CTRLCLEAR")
}

record(fanout, "MGNT:UNDS:1:QUADFUNCGO") {
  field(LNK1, "QUAD:UNDS:1680:ALLFUNCGO")
  field(LNK2, "QUAD:UNDS:1980:ALLFUNCGO")
  field(LNK3, "QUAD:UNDS:2180:ALLFUNCGO")
  field(LNK4, "QUAD:UNDS:2480:ALLFUNCGO")
  field(LNK5, "QUAD:UNDS:2680:ALLFUNCGO")
  field(LNK6, "QUAD:UNDS:2780:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:QUADFUNCGO1")
}

record(fanout, "MGNT:UNDS:1:QUADFUNCGO1") {
  field(LNK1, "QUAD:UNDS:2880:ALLFUNCGO")
  field(LNK2, "QUAD:UNDS:2980:ALLFUNCGO")
  field(LNK3, "QUAD:UNDS:3080:ALLFUNCGO")
  field(LNK4, "QUAD:UNDS:3180:ALLFUNCGO")
  field(LNK5, "QUAD:UNDS:3280:ALLFUNCGO")
  field(LNK6, "QUAD:UNDS:3380:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:QUADFUNCGO2")
}

record(fanout, "MGNT:UNDS:1:QUADFUNCGO2") {
  field(LNK1, "QUAD:UNDS:3480:ALLFUNCGO")
  field(LNK2, "QUAD:UNDS:3580:ALLFUNCGO")
  field(LNK3, "QUAD:UNDS:3680:ALLFUNCGO")
  field(LNK4, "QUAD:UNDS:3780:ALLFUNCGO")
  field(LNK5, "QUAD:UNDS:3880:ALLFUNCGO")
  field(LNK6, "QUAD:UNDS:3980:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:QUADFUNCGO3")
}

record(fanout, "MGNT:UNDS:1:QUADFUNCGO3") {
  field(LNK1, "QUAD:UNDS:4080:ALLFUNCGO")
  field(LNK2, "QUAD:UNDS:4180:ALLFUNCGO")
  field(LNK3, "QUAD:UNDS:4280:ALLFUNCGO")
  field(LNK4, "QUAD:UNDS:4380:ALLFUNCGO")
  field(LNK5, "QUAD:UNDS:4480:ALLFUNCGO")
  field(LNK6, "QUAD:UNDS:4580:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:QUADFUNCGO4")
}

record(fanout, "MGNT:UNDS:1:QUADFUNCGO4") {
  field(LNK1, "QUAD:UNDS:4680:ALLFUNCGO")
  field(LNK2, "QUAD:UNDS:4780:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:CTRLCLEAR")
}

record(fanout, "MGNT:UNDS:1:XCORFUNCGO") {
  field(LNK1, "XCOR:UNDS:1680:ALLFUNCGO")
  field(LNK2, "XCOR:UNDS:1980:ALLFUNCGO")
  field(LNK3, "XCOR:UNDS:2180:ALLFUNCGO")
  field(LNK4, "XCOR:UNDS:2480:ALLFUNCGO")
  field(LNK5, "XCOR:UNDS:2680:ALLFUNCGO")
  field(LNK6, "XCOR:UNDS:2780:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:XCORFUNCGO1")
}

record (fanout, "MGNT:UNDS:1:XCORFUNCGO1") {
  field(LNK1, "XCOR:UNDS:2880:ALLFUNCGO")
  field(LNK2, "XCOR:UNDS:2980:ALLFUNCGO")
  field(LNK3, "XCOR:UNDS:3080:ALLFUNCGO")
  field(LNK4, "XCOR:UNDS:3180:ALLFUNCGO")
  field(LNK5, "XCOR:UNDS:3280:ALLFUNCGO")
  field(LNK6, "XCOR:UNDS:3380:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:XCORFUNCGO2")
}

record (fanout, "MGNT:UNDS:1:XCORFUNCGO2") {
  field(LNK1, "XCOR:UNDS:3480:ALLFUNCGO")
  field(LNK2, "XCOR:UNDS:3580:ALLFUNCGO")
  field(LNK3, "XCOR:UNDS:3680:ALLFUNCGO")
  field(LNK4, "XCOR:UNDS:3780:ALLFUNCGO")
  field(LNK5, "XCOR:UNDS:3880:ALLFUNCGO")
  field(LNK6, "XCOR:UNDS:3980:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:XCORFUNCGO3")
}

record (fanout, "MGNT:UNDS:1:XCORFUNCGO3") {
  field(LNK1, "XCOR:UNDS:4080:ALLFUNCGO")
  field(LNK2, "XCOR:UNDS:4180:ALLFUNCGO")
  field(LNK3, "XCOR:UNDS:4280:ALLFUNCGO")
  field(LNK4, "XCOR:UNDS:4380:ALLFUNCGO")
  field(LNK5, "XCOR:UNDS:4480:ALLFUNCGO")
  field(LNK6, "XCOR:UNDS:4580:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:XCORFUNCGO4")
}

record (fanout, "MGNT:UNDS:1:XCORFUNCGO4") {
  field(LNK1, "XCOR:UNDS:4680:ALLFUNCGO")
  field(LNK2, "XCOR:UNDS:4780:ALLFUNCGO")
  field(LNK3, "XCOR:UNDS:4982:ALLFUNCGO")
  field(LNK4, "XCOR:UNDS:5038:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:CTRLCLEAR")
}

record(fanout, "MGNT:UNDS:1:YCORFUNCGO") {
  field(LNK1, "YCOR:UNDS:1680:ALLFUNCGO")
  field(LNK2, "YCOR:UNDS:1980:ALLFUNCGO")
  field(LNK3, "YCOR:UNDS:2180:ALLFUNCGO")
  field(LNK4, "YCOR:UNDS:2480:ALLFUNCGO")
  field(LNK5, "YCOR:UNDS:2680:ALLFUNCGO")
  field(LNK6, "YCOR:UNDS:2780:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:YCORFUNCGO1")
}

record (fanout, "MGNT:UNDS:1:YCORFUNCGO1") {
  field(LNK1, "YCOR:UNDS:2880:ALLFUNCGO")
  field(LNK2, "YCOR:UNDS:2980:ALLFUNCGO")
  field(LNK3, "YCOR:UNDS:3080:ALLFUNCGO")
  field(LNK4, "YCOR:UNDS:3180:ALLFUNCGO")
  field(LNK5, "YCOR:UNDS:4280:ALLFUNCGO")
  field(LNK6, "YCOR:UNDS:3380:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:YCORFUNCGO2")
}

record (fanout, "MGNT:UNDS:1:YCORFUNCGO2") {
  field(LNK1, "YCOR:UNDS:3480:ALLFUNCGO")
  field(LNK2, "YCOR:UNDS:3580:ALLFUNCGO")
  field(LNK3, "YCOR:UNDS:3680:ALLFUNCGO")
  field(LNK4, "YCOR:UNDS:3780:ALLFUNCGO")
  field(LNK5, "YCOR:UNDS:3880:ALLFUNCGO")
  field(LNK6, "YCOR:UNDS:3980:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:YCORFUNCGO3")
}

record (fanout, "MGNT:UNDS:1:YCORFUNCGO3") {
  field(LNK1, "YCOR:UNDS:4080:ALLFUNCGO")
  field(LNK2, "YCOR:UNDS:4180:ALLFUNCGO")
  field(LNK3, "YCOR:UNDS:4280:ALLFUNCGO")
  field(LNK4, "YCOR:UNDS:4380:ALLFUNCGO")
  field(LNK5, "YCOR:UNDS:4480:ALLFUNCGO")
  field(LNK6, "YCOR:UNDS:4580:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:YCORFUNCGO4")
}

record (fanout, "MGNT:UNDS:1:YCORFUNCGO4") {
  field(LNK1, "YCOR:UNDS:4680:ALLFUNCGO")
  field(LNK2, "YCOR:UNDS:4780:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:1:CTRLCLEAR")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBDEND

record(seq, "MGNT:UNDH:2:ALLXCORSSEL") {
  field(DOL1, "MGNT:UNDH:2:ALLXCORS")
  field(DOL2, "MGNT:UNDH:2:ALLXCORS")
  field(DOL3, "MGNT:UNDH:2:ALLXCORS")
  field(DOL4, "MGNT:UNDH:2:ALLXCORS")
  field(DOL5, "MGNT:UNDH:2:ALLXCORS")
  field(LNK1, "EFC:UNDH:1450:X:SELECT PP NMS")
  field(LNK2, "EFC:UNDH:1550:X:SELECT PP NMS")
  field(LNK3, "EFC:UNDH:1650:X:SELECT PP NMS")
  field(LNK4, "EFC:UNDH:1750:X:SELECT PP NMS")
  field(LNK5, "EFC:UNDH:1850:X:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:2:ALLXCORSSEL1")
}
record(seq, "MGNT:UNDH:2:ALLXCORSSEL1") {
  field(DOL1, "MGNT:UNDH:2:ALLXCORS")
  field(DOL2, "MGNT:UNDH:2:ALLXCORS")
  field(DOL3, "MGNT:UNDH:2:ALLXCORS")
  field(DOL4, "MGNT:UNDH:2:ALLXCORS")
  field(DOL5, "MGNT:UNDH:2:ALLXCORS")
  field(DOL6, "MGNT:UNDH:2:ALLXCORS")
  field(DOL7, "MGNT:UNDH:2:ALLXCORS")
  field(DOL8, "MGNT:UNDH:2:ALLXCORS")
  field(LNK1, "EFC:UNDH:1950:X:SELECT PP NMS")
  field(LNK2, "EFC:UNDH:2050:X:SELECT PP NMS")
  field(LNK3, "EFC:UNDH:2250:X:SELECT PP NMS")
  field(LNK4, "EFC:UNDH:2350:X:SELECT PP NMS")
  field(LNK5, "EFC:UNDH:2450:X:SELECT PP NMS")
  field(LNK6, "EFC:UNDH:2550:X:SELECT PP NMS")
  field(LNK7, "EFC:UNDH:2650:X:SELECT PP NMS")
  field(LNK8, "EFC:UNDH:2750:X:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:2:ALLXCORSSEL2")
}
record(seq, "MGNT:UNDH:2:ALLXCORSSEL2") {
  field(DOL1, "MGNT:UNDH:2:ALLXCORS")
  field(DOL2, "MGNT:UNDH:2:ALLXCORS")
  field(DOL3, "MGNT:UNDH:2:ALLXCORS")
  field(DOL4, "MGNT:UNDH:2:ALLXCORS")
  field(DOL5, "MGNT:UNDH:2:ALLXCORS")
  field(DOL6, "MGNT:UNDH:2:ALLXCORS")
  field(DOL7, "MGNT:UNDH:2:ALLXCORS")
  field(DOL8, "MGNT:UNDH:2:ALLXCORS")
  field(DOL9, "MGNT:UNDH:2:ALLXCORS")
  field(DOLA, "MGNT:UNDH:2:ALLXCORS")
  field(LNK1, "EFC:UNDH:2950:X:SELECT PP NMS")
  field(LNK2, "EFC:UNDH:3050:X:SELECT PP NMS")
  field(LNK3, "EFC:UNDH:3150:X:SELECT PP NMS")
  field(LNK4, "EFC:UNDH:3250:X:SELECT PP NMS")
  field(LNK5, "EFC:UNDH:3350:X:SELECT PP NMS")
  field(LNK6, "EFC:UNDH:3450:X:SELECT PP NMS")
  field(LNK7, "EFC:UNDH:3550:X:SELECT PP NMS")
  field(LNK8, "EFC:UNDH:3650:X:SELECT PP NMS")
  field(LNK9, "EFC:UNDH:3750:X:SELECT PP NMS")
  field(LNKA, "EFC:UNDH:3850:X:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:2:ALLXCORSSEL3")
}
record(seq, "MGNT:UNDH:2:ALLXCORSSEL3") {
  field(DOL1, "MGNT:UNDH:2:ALLXCORS")
  field(DOL2, "MGNT:UNDH:2:ALLXCORS")
  field(DOL3, "MGNT:UNDH:2:ALLXCORS")
  field(DOL4, "MGNT:UNDH:2:ALLXCORS")
  field(DOL5, "MGNT:UNDH:2:ALLXCORS")
  field(DOL6, "MGNT:UNDH:2:ALLXCORS")
  field(DOL7, "MGNT:UNDH:2:ALLXCORS")
  field(DOL8, "MGNT:UNDH:2:ALLXCORS")
  field(DOL9, "MGNT:UNDH:2:ALLXCORS")
  field(LNK1, "EFC:UNDH:3950:X:SELECT PP NMS")
  field(LNK2, "EFC:UNDH:4050:X:SELECT PP NMS")
  field(LNK3, "EFC:UNDH:4150:X:SELECT PP NMS")
  field(LNK4, "EFC:UNDH:4250:X:SELECT PP NMS")
  field(LNK5, "EFC:UNDH:4350:X:SELECT PP NMS")
  field(LNK6, "EFC:UNDH:4450:X:SELECT PP NMS")
  field(LNK7, "EFC:UNDH:4550:X:SELECT PP NMS")
  field(LNK8, "EFC:UNDH:4650:X:SELECT PP NMS")
  field(LNK9, "EFC:UNDH:4750:X:SELECT PP NMS")
}

record(seq, "MGNT:UNDH:2:ALLYCORSSEL") {
  field(DOL1, "MGNT:UNDH:2:ALLYCORS")
  field(DOL2, "MGNT:UNDH:2:ALLYCORS")
  field(DOL3, "MGNT:UNDH:2:ALLYCORS")
  field(DOL4, "MGNT:UNDH:2:ALLYCORS")
  field(DOL5, "MGNT:UNDH:2:ALLYCORS")
  field(LNK1, "EFC:UNDH:1450:Y:SELECT PP NMS")
  field(LNK2, "EFC:UNDH:1550:Y:SELECT PP NMS")
  field(LNK3, "EFC:UNDH:1650:Y:SELECT PP NMS")
  field(LNK4, "EFC:UNDH:1750:Y:SELECT PP NMS")
  field(LNK5, "EFC:UNDH:1850:Y:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:2:ALLYCORSSEL1")
}
record(seq, "MGNT:UNDH:2:ALLYCORSSEL1") {
  field(DOL1, "MGNT:UNDH:2:ALLYCORS")
  field(DOL2, "MGNT:UNDH:2:ALLYCORS")
  field(DOL3, "MGNT:UNDH:2:ALLYCORS")
  field(DOL4, "MGNT:UNDH:2:ALLYCORS")
  field(DOL5, "MGNT:UNDH:2:ALLYCORS")
  field(DOL6, "MGNT:UNDH:2:ALLYCORS")
  field(DOL7, "MGNT:UNDH:2:ALLYCORS")
  field(DOL8, "MGNT:UNDH:2:ALLYCORS")
  field(LNK1, "EFC:UNDH:1950:Y:SELECT PP NMS")
  field(LNK2, "EFC:UNDH:2050:Y:SELECT PP NMS")
  field(LNK3, "EFC:UNDH:2250:Y:SELECT PP NMS")
  field(LNK4, "EFC:UNDH:2350:Y:SELECT PP NMS")
  field(LNK5, "EFC:UNDH:2450:Y:SELECT PP NMS")
  field(LNK6, "EFC:UNDH:2550:Y:SELECT PP NMS")
  field(LNK7, "EFC:UNDH:2650:Y:SELECT PP NMS")
  field(LNK8, "EFC:UNDH:2750:Y:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:2:ALLYCORSSEL2")
}
record(seq, "MGNT:UNDH:2:ALLYCORSSEL2") {
  field(DOL1, "MGNT:UNDH:2:ALLYCORS")
  field(DOL2, "MGNT:UNDH:2:ALLYCORS")
  field(DOL3, "MGNT:UNDH:2:ALLYCORS")
  field(DOL4, "MGNT:UNDH:2:ALLYCORS")
  field(DOL5, "MGNT:UNDH:2:ALLYCORS")
  field(DOL6, "MGNT:UNDH:2:ALLYCORS")
  field(DOL7, "MGNT:UNDH:2:ALLYCORS")
  field(DOL8, "MGNT:UNDH:2:ALLYCORS")
  field(DOL9, "MGNT:UNDH:2:ALLYCORS")
  field(DOLA, "MGNT:UNDH:2:ALLYCORS")
  field(LNK1, "EFC:UNDH:2950:Y:SELECT PP NMS")
  field(LNK2, "EFC:UNDH:3050:Y:SELECT PP NMS")
  field(LNK3, "EFC:UNDH:3150:Y:SELECT PP NMS")
  field(LNK4, "EFC:UNDH:3250:Y:SELECT PP NMS")
  field(LNK5, "EFC:UNDH:3350:Y:SELECT PP NMS")
  field(LNK6, "EFC:UNDH:3450:Y:SELECT PP NMS")
  field(LNK7, "EFC:UNDH:3550:Y:SELECT PP NMS")
  field(LNK8, "EFC:UNDH:3650:Y:SELECT PP NMS")
  field(LNK9, "EFC:UNDH:3750:Y:SELECT PP NMS")
  field(LNKA, "EFC:UNDH:3850:Y:SELECT PP NMS")
  field(FLNK, "MGNT:UNDH:2:ALLYCORSSEL3")
}
record(seq, "MGNT:UNDH:2:ALLYCORSSEL3") {
  field(DOL1, "MGNT:UNDH:2:ALLYCORS")
  field(DOL2, "MGNT:UNDH:2:ALLYCORS")
  field(DOL3, "MGNT:UNDH:2:ALLYCORS")
  field(DOL4, "MGNT:UNDH:2:ALLYCORS")
  field(DOL5, "MGNT:UNDH:2:ALLYCORS")
  field(DOL6, "MGNT:UNDH:2:ALLYCORS")
  field(DOL7, "MGNT:UNDH:2:ALLYCORS")
  field(DOL8, "MGNT:UNDH:2:ALLYCORS")
  field(DOL9, "MGNT:UNDH:2:ALLYCORS")
  field(LNK1, "EFC:UNDH:3950:Y:SELECT PP NMS")
  field(LNK2, "EFC:UNDH:4050:Y:SELECT PP NMS")
  field(LNK3, "EFC:UNDH:4150:Y:SELECT PP NMS")
  field(LNK4, "EFC:UNDH:4250:Y:SELECT PP NMS")
  field(LNK5, "EFC:UNDH:4350:Y:SELECT PP NMS")
  field(LNK6, "EFC:UNDH:4450:Y:SELECT PP NMS")
  field(LNK7, "EFC:UNDH:4550:Y:SELECT PP NMS")
  field(LNK8, "EFC:UNDH:4650:Y:SELECT PP NMS")
  field(LNK9, "EFC:UNDH:4750:Y:SELECT PP NMS")
}

record(seq, "MGNT:UNDH:2:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:UNDH:2:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:UNDH:2:XCORFUNCGO.PROC")
  field(LNK3, "MGNT:UNDH:2:YCORFUNCGO.PROC")
  field(LNK4, "MGNT:UNDH:2:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:UNDH:2:CTRLCLEAR")
}

record(fanout, "MGNT:UNDH:2:XCORFUNCGO") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "EFC:UNDH:1450:X:ALLFUNCGO")
  field(LNK2, "EFC:UNDH:1550:X:ALLFUNCGO")
  field(LNK3, "EFC:UNDH:1650:X:ALLFUNCGO")
  field(LNK4, "EFC:UNDH:1750:X:ALLFUNCGO")
  field(LNK5, "EFC:UNDH:1850:X:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:2:XCORFUNCGO1")
}
record (fanout, "MGNT:UNDH:2:XCORFUNCGO1") {
  field(LNK1, "EFC:UNDH:1950:X:ALLFUNCGO")
  field(LNK2, "EFC:UNDH:2050:X:ALLFUNCGO")
  field(LNK3, "EFC:UNDH:2250:X:ALLFUNCGO")
  field(LNK4, "EFC:UNDH:2350:X:ALLFUNCGO")
  field(LNK5, "EFC:UNDH:2450:X:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:2:XCORFUNCGO2")
}
record (fanout, "MGNT:UNDH:2:XCORFUNCGO2") {
  field(LNK1, "EFC:UNDH:2550:X:ALLFUNCGO")
  field(LNK2, "EFC:UNDH:2650:X:ALLFUNCGO")
  field(LNK3, "EFC:UNDH:2750:X:ALLFUNCGO")
  field(LNK4, "EFC:UNDH:2950:X:ALLFUNCGO")
  field(LNK5, "EFC:UNDH:3050:X:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:2:XCORFUNCGO3")
}
record (fanout, "MGNT:UNDH:2:XCORFUNCGO3") {
  field(LNK1, "EFC:UNDH:3150:X:ALLFUNCGO")
  field(LNK2, "EFC:UNDH:3250:X:ALLFUNCGO")
  field(LNK3, "EFC:UNDH:3350:X:ALLFUNCGO")
  field(LNK4, "EFC:UNDH:3450:X:ALLFUNCGO")
  field(LNK5, "EFC:UNDH:3550:X:ALLFUNCGO")
  field(LNK6, "EFC:UNDH:3650:X:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:2:XCORFUNCGO4")
}
record (fanout, "MGNT:UNDH:2:XCORFUNCGO4") {
  field(LNK1, "EFC:UNDH:3750:X:ALLFUNCGO")
  field(LNK2, "EFC:UNDH:3850:X:ALLFUNCGO")
  field(LNK3, "EFC:UNDH:3950:X:ALLFUNCGO")
  field(LNK4, "EFC:UNDH:4050:X:ALLFUNCGO")
  field(LNK5, "EFC:UNDH:4150:X:ALLFUNCGO")
  field(LNK6, "EFC:UNDH:4250:X:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:2:XCORFUNCGO5")
}
record (fanout, "MGNT:UNDH:2:XCORFUNCGO5") {
  field(LNK1, "EFC:UNDH:4350:X:ALLFUNCGO")
  field(LNK2, "EFC:UNDH:4450:X:ALLFUNCGO")
  field(LNK3, "EFC:UNDH:4550:X:ALLFUNCGO")
  field(LNK4, "EFC:UNDH:4650:X:ALLFUNCGO")
  field(LNK5, "EFC:UNDH:4750:X:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:2:CTRLCLEAR")
}

record(fanout, "MGNT:UNDH:2:YCORFUNCGO") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "EFC:UNDH:1450:Y:ALLFUNCGO")
  field(LNK2, "EFC:UNDH:1550:Y:ALLFUNCGO")
  field(LNK3, "EFC:UNDH:1650:Y:ALLFUNCGO")
  field(LNK4, "EFC:UNDH:1750:Y:ALLFUNCGO")
  field(LNK5, "EFC:UNDH:1850:Y:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:2:YCORFUNCGO1")
}
record (fanout, "MGNT:UNDH:2:YCORFUNCGO1") {
  field(LNK1, "EFC:UNDH:1950:Y:ALLFUNCGO")
  field(LNK2, "EFC:UNDH:2050:Y:ALLFUNCGO")
  field(LNK3, "EFC:UNDH:2250:Y:ALLFUNCGO")
  field(LNK4, "EFC:UNDH:2350:Y:ALLFUNCGO")
  field(LNK5, "EFC:UNDH:2450:Y:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:2:YCORFUNCGO2")
}
record (fanout, "MGNT:UNDH:2:YCORFUNCGO2") {
  field(LNK1, "EFC:UNDH:2550:Y:ALLFUNCGO")
  field(LNK2, "EFC:UNDH:2650:Y:ALLFUNCGO")
  field(LNK3, "EFC:UNDH:2750:Y:ALLFUNCGO")
  field(LNK4, "EFC:UNDH:2950:Y:ALLFUNCGO")
  field(LNK5, "EFC:UNDH:3050:Y:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:2:YCORFUNCGO3")
}
record (fanout, "MGNT:UNDH:2:YCORFUNCGO3") {
  field(LNK1, "EFC:UNDH:3150:Y:ALLFUNCGO")
  field(LNK2, "EFC:UNDH:3250:Y:ALLFUNCGO")
  field(LNK3, "EFC:UNDH:3350:Y:ALLFUNCGO")
  field(LNK4, "EFC:UNDH:3450:Y:ALLFUNCGO")
  field(LNK5, "EFC:UNDH:3550:Y:ALLFUNCGO")
  field(LNK6, "EFC:UNDH:3650:Y:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:2:YCORFUNCGO4")
}
record (fanout, "MGNT:UNDH:2:YCORFUNCGO4") {
  field(LNK1, "EFC:UNDH:3750:Y:ALLFUNCGO")
  field(LNK2, "EFC:UNDH:3850:Y:ALLFUNCGO")
  field(LNK3, "EFC:UNDH:3950:Y:ALLFUNCGO")
  field(LNK4, "EFC:UNDH:4050:Y:ALLFUNCGO")
  field(LNK5, "EFC:UNDH:4150:Y:ALLFUNCGO")
  field(LNK6, "EFC:UNDH:4250:Y:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:2:YCORFUNCGO5")
}
record (fanout, "MGNT:UNDH:2:YCORFUNCGO5") {
  field(LNK1, "EFC:UNDH:4350:Y:ALLFUNCGO")
  field(LNK2, "EFC:UNDH:4450:Y:ALLFUNCGO")
  field(LNK3, "EFC:UNDH:4550:Y:ALLFUNCGO")
  field(LNK4, "EFC:UNDH:4650:Y:ALLFUNCGO")
  field(LNK5, "EFC:UNDH:4750:Y:ALLFUNCGO")
  field(FLNK, "MGNT:UNDH:2:CTRLCLEAR")
}

# End of file
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBDEND

record(seq, "MGNT:UNDS:2:ALLXCORSSEL") {
  field(DOL1, "MGNT:UNDS:2:ALLXCORS")
  field(DOL2, "MGNT:UNDS:2:ALLXCORS")
  field(DOL3, "MGNT:UNDS:2:ALLXCORS")
  field(DOL4, "MGNT:UNDS:2:ALLXCORS")
  field(DOL5, "MGNT:UNDS:2:ALLXCORS")
  field(DOL6, "MGNT:UNDS:2:ALLXCORS")
  field(DOL7, "MGNT:UNDS:2:ALLXCORS")
  field(DOL8, "MGNT:UNDS:2:ALLXCORS")
  field(DOL9, "MGNT:UNDS:2:ALLXCORS")
  field(DOLA, "MGNT:UNDS:2:ALLXCORS")
  field(LNK1, "EFC:UNDS:2650:X:SELECT PP NMS")
  field(LNK2, "EFC:UNDS:2750:X:SELECT PP NMS")
  field(LNK3, "EFC:UNDS:2850:X:SELECT PP NMS")
  field(LNK4, "EFC:UNDS:2950:X:SELECT PP NMS")
  field(LNK5, "EFC:UNDS:3050:X:SELECT PP NMS")
  field(LNK6, "EFC:UNDS:3150:X:SELECT PP NMS")
  field(LNK7, "EFC:UNDS:3250:X:SELECT PP NMS")
  field(LNK8, "EFC:UNDS:3350:X:SELECT PP NMS")
  field(LNK9, "EFC:UNDS:3450:X:SELECT PP NMS")
  field(LNKA, "EFC:UNDS:3650:X:SELECT PP NMS")
  field(FLNK, "MGNT:UNDS:2:ALLXCORSSEL1")
}
record(seq, "MGNT:UNDS:2:ALLXCORSSEL1") {
  field(DOL1, "MGNT:UNDS:2:ALLXCORS")
  field(DOL2, "MGNT:UNDS:2:ALLXCORS")
  field(DOL3, "MGNT:UNDS:2:ALLXCORS")
  field(DOL4, "MGNT:UNDS:2:ALLXCORS")
  field(DOL5, "MGNT:UNDS:2:ALLXCORS")
  field(DOL6, "MGNT:UNDS:2:ALLXCORS")
  field(DOL7, "MGNT:UNDS:2:ALLXCORS")
  field(DOL8, "MGNT:UNDS:2:ALLXCORS")
  field(DOL9, "MGNT:UNDS:2:ALLXCORS")
  field(DOLA, "MGNT:UNDS:2:ALLXCORS")
  field(LNK1, "EFC:UNDS:3750:X:SELECT PP NMS")
  field(LNK2, "EFC:UNDS:3850:X:SELECT PP NMS")
  field(LNK3, "EFC:UNDS:3950:X:SELECT PP NMS")
  field(LNK4, "EFC:UNDS:4050:X:SELECT PP NMS")
  field(LNK5, "EFC:UNDS:4150:X:SELECT PP NMS")
  field(LNK6, "EFC:UNDS:4250:X:SELECT PP NMS")
  field(LNK7, "EFC:UNDS:4350:X:SELECT PP NMS")
  field(LNK8, "EFC:UNDS:4450:X:SELECT PP NMS")
  field(LNK9, "EFC:UNDS:4550:X:SELECT PP NMS")
  field(LNKA, "EFC:UNDS:4650:X:SELECT PP NMS")
  field(FLNK, "MGNT:UNDS:2:ALLXCORSSEL2")
}
record(seq, "MGNT:UNDS:2:ALLXCORSSEL2") {
  field(DOL1, "MGNT:UNDS:2:ALLXCORS")
  field(LNK1, "EFC:UNDS:4750:X:SELECT PP NMS")
}

record(seq, "MGNT:UNDS:2:ALLYCORSSEL") {
  field(DOL1, "MGNT:UNDS:2:ALLYCORS")
  field(DOL2, "MGNT:UNDS:2:ALLYCORS")
  field(DOL3, "MGNT:UNDS:2:ALLYCORS")
  field(DOL4, "MGNT:UNDS:2:ALLYCORS")
  field(DOL5, "MGNT:UNDS:2:ALLYCORS")
  field(DOL6, "MGNT:UNDS:2:ALLYCORS")
  field(DOL7, "MGNT:UNDS:2:ALLYCORS")
  field(DOL8, "MGNT:UNDS:2:ALLYCORS")
  field(DOL9, "MGNT:UNDS:2:ALLYCORS")
  field(DOLA, "MGNT:UNDS:2:ALLYCORS")
  field(LNK1, "EFC:UNDS:2650:Y:SELECT PP NMS")
  field(LNK2, "EFC:UNDS:2750:Y:SELECT PP NMS")
  field(LNK3, "EFC:UNDS:2850:Y:SELECT PP NMS")
  field(LNK4, "EFC:UNDS:2950:Y:SELECT PP NMS")
  field(LNK5, "EFC:UNDS:3050:Y:SELECT PP NMS")
  field(LNK6, "EFC:UNDS:3150:Y:SELECT PP NMS")
  field(LNK7, "EFC:UNDS:3250:Y:SELECT PP NMS")
  field(LNK8, "EFC:UNDS:3350:Y:SELECT PP NMS")
  field(LNK9, "EFC:UNDS:3450:Y:SELECT PP NMS")
  field(LNKA, "EFC:UNDS:3650:Y:SELECT PP NMS")
  field(FLNK, "MGNT:UNDS:2:ALLYCORSSEL1")
}
record(seq, "MGNT:UNDS:2:ALLYCORSSEL1") {
  field(DOL1, "MGNT:UNDS:2:ALLYCORS")
  field(DOL2, "MGNT:UNDS:2:ALLYCORS")
  field(DOL3, "MGNT:UNDS:2:ALLYCORS")
  field(DOL4, "MGNT:UNDS:2:ALLYCORS")
  field(DOL5, "MGNT:UNDS:2:ALLYCORS")
  field(DOL6, "MGNT:UNDS:2:ALLYCORS")
  field(DOL7, "MGNT:UNDS:2:ALLYCORS")
  field(DOL8, "MGNT:UNDS:2:ALLYCORS")
  field(DOL9, "MGNT:UNDS:2:ALLYCORS")
  field(DOLA, "MGNT:UNDS:2:ALLYCORS")
  field(LNK1, "EFC:UNDS:3750:Y:SELECT PP NMS")
  field(LNK2, "EFC:UNDS:3850:Y:SELECT PP NMS")
  field(LNK3, "EFC:UNDS:3950:Y:SELECT PP NMS")
  field(LNK4, "EFC:UNDS:4050:Y:SELECT PP NMS")
  field(LNK5, "EFC:UNDS:4150:Y:SELECT PP NMS")
  field(LNK6, "EFC:UNDS:4250:Y:SELECT PP NMS")
  field(LNK7, "EFC:UNDS:4350:Y:SELECT PP NMS")
  field(LNK8, "EFC:UNDS:4450:Y:SELECT PP NMS")
  field(LNK9, "EFC:UNDS:4550:Y:SELECT PP NMS")
  field(LNKA, "EFC:UNDS:4650:Y:SELECT PP NMS")
  field(FLNK, "MGNT:UNDS:2:ALLYCORSSEL2")
}
record(seq, "MGNT:UNDS:2:ALLYCORSSEL2") {
  field(DOL1, "MGNT:UNDS:2:ALLYCORS")
  field(LNK1, "EFC:UNDS:4750:Y:SELECT PP NMS")
}

record(seq, "MGNT:UNDS:2:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:UNDS:2:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:UNDS:2:XCORFUNCGO.PROC")
  field(LNK3, "MGNT:UNDS:2:YCORFUNCGO.PROC")
  field(LNK4, "MGNT:UNDS:2:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:UNDS:2:CTRLCLEAR")
}

record(fanout, "MGNT:UNDS:2:XCORFUNCGO") {
  field(LNK1, "EFC:UNDS:2650:X:ALLFUNCGO")
  field(LNK2, "EFC:UNDS:2750:X:ALLFUNCGO")
  field(LNK3, "EFC:UNDS:2850:X:ALLFUNCGO")
  field(LNK4, "EFC:UNDS:2950:X:ALLFUNCGO")
  field(LNK5, "EFC:UNDS:3050:X:ALLFUNCGO")
  field(LNK6, "EFC:UNDS:3150:X:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:2:XCORFUNCGO1")
}
record (fanout, "MGNT:UNDS:2:XCORFUNCGO1") {
  field(LNK1, "EFC:UNDS:3250:X:ALLFUNCGO")
  field(LNK2, "EFC:UNDS:3350:X:ALLFUNCGO")
  field(LNK3, "EFC:UNDS:3450:X:ALLFUNCGO")
  field(LNK4, "EFC:UNDS:3650:X:ALLFUNCGO")
  field(LNK5, "EFC:UNDS:3750:X:ALLFUNCGO")
  field(LNK6, "EFC:UNDS:3850:X:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:2:XCORFUNCGO2")
}
record (fanout, "MGNT:UNDS:2:XCORFUNCGO2") {
  field(LNK1, "EFC:UNDS:3950:X:ALLFUNCGO")
  field(LNK2, "EFC:UNDS:4150:X:ALLFUNCGO")
  field(LNK3, "EFC:UNDS:4250:X:ALLFUNCGO")
  field(LNK4, "EFC:UNDS:4350:X:ALLFUNCGO")
  field(LNK5, "EFC:UNDS:4450:X:ALLFUNCGO")
  field(LNK6, "EFC:UNDS:4550:X:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:2:XCORFUNCGO3")
}
record (fanout, "MGNT:UNDS:2:XCORFUNCGO3") {
  field(LNK1, "EFC:UNDS:4650:X:ALLFUNCGO")
  field(LNK2, "EFC:UNDS:4750:X:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:2:CTRLCLEAR")
}

record(fanout, "MGNT:UNDS:2:YCORFUNCGO") {
  field(LNK1, "EFC:UNDS:2650:Y:ALLFUNCGO")
  field(LNK2, "EFC:UNDS:2750:Y:ALLFUNCGO")
  field(LNK3, "EFC:UNDS:2850:Y:ALLFUNCGO")
  field(LNK4, "EFC:UNDS:2950:Y:ALLFUNCGO")
  field(LNK5, "EFC:UNDS:3050:Y:ALLFUNCGO")
  field(LNK6, "EFC:UNDS:3150:Y:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:2:YCORFUNCGO1")
}
record (fanout, "MGNT:UNDS:2:YCORFUNCGO1") {
  field(LNK1, "EFC:UNDS:3250:Y:ALLFUNCGO")
  field(LNK2, "EFC:UNDS:3350:Y:ALLFUNCGO")
  field(LNK3, "EFC:UNDS:3450:Y:ALLFUNCGO")
  field(LNK4, "EFC:UNDS:3650:Y:ALLFUNCGO")
  field(LNK5, "EFC:UNDS:3750:Y:ALLFUNCGO")
  field(LNK6, "EFC:UNDS:3850:Y:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:2:YCORFUNCGO2")
}
record (fanout, "MGNT:UNDS:2:YCORFUNCGO2") {
  field(LNK1, "EFC:UNDS:3950:Y:ALLFUNCGO")
  field(LNK2, "EFC:UNDS:4150:Y:ALLFUNCGO")
  field(LNK3, "EFC:UNDS:4250:Y:ALLFUNCGO")
  field(LNK4, "EFC:UNDS:4350:Y:ALLFUNCGO")
  field(LNK5, "EFC:UNDS:4450:Y:ALLFUNCGO")
  field(LNK6, "EFC:UNDS:4550:Y:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:2:YCORFUNCGO3")
}
record (fanout, "MGNT:UNDS:2:YCORFUNCGO3") {
  field(LNK1, "EFC:UNDS:4650:Y:ALLFUNCGO")
  field(LNK2, "EFC:UNDS:4750:Y:ALLFUNCGO")
  field(FLNK, "MGNT:UNDS:2:CTRLCLEAR")
}

# End of file
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:UNDH:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "LGPS:UNDH:1:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:UNDH:1:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:UNDH:1:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:UNDH:1:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:UNDH:1:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:UNDH:1:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:UNDH:1:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:UNDH:1:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:UNDH:1:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:UNDH:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:UNDH:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:UNDH:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:UNDH:1:EDES.PROC PP")
    field(LNK2, "LGPS:UNDH:1:EACT.PROC PP")
    field(LNK3, "LGPS:UNDH:1:EERR.DISA PP")
    field(LNK4, "LGPS:UNDH:1:ECON.PROC PP")
    field(LNK5, "LGPS:UNDH:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:UNDH:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:UNDH:1:BLEM.PROC PP")
    field(LNK8, "LGPS:UNDH:1:BMOD.PROC PP")
    field(LNK9, "LGPS:UNDH:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:UNDH:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:UNDH:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:UNDH:1:BMAX")
  field(DOL2, "LGPS:UNDH:1:BMAX")
  field(DOL3, "LGPS:UNDH:1:BMAX")
  field(DOL4, "LGPS:UNDH:1:BMIN")
  field(DOL5, "LGPS:UNDH:1:BMIN")
  field(DOL6, "LGPS:UNDH:1:BMIN")
  field(LNK1, "LGPS:UNDH:1:BMAGX.HOPR")
  field(LNK2, "LGPS:UNDH:1:BMAGY.HOPR")
  field(LNK3, "LGPS:UNDH:1:BLEM.HOPR")
  field(LNK4, "LGPS:UNDH:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:UNDH:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:UNDH:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:UNDH:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:UNDH:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:UNDH:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:UNDH:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:UNDH:1:EDES NPP MS")
  field(INPB, "LGPS:UNDH:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:UNDH:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "LGPS:UNDH:2:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:UNDH:2:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:UNDH:2:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:UNDH:2:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:UNDH:2:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:UNDH:2:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:UNDH:2:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:UNDH:2:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:UNDH:2:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:UNDH:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:UNDH:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:UNDH:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:UNDH:2:EDES.PROC PP")
    field(LNK2, "LGPS:UNDH:2:EACT.PROC PP")
    field(LNK3, "LGPS:UNDH:2:EERR.DISA PP")
    field(LNK4, "LGPS:UNDH:2:ECON.PROC PP")
    field(LNK5, "LGPS:UNDH:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:UNDH:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:UNDH:2:BLEM.PROC PP")
    field(LNK8, "LGPS:UNDH:2:BMOD.PROC PP")
    field(LNK9, "LGPS:UNDH:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:UNDH:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:UNDH:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:UNDH:2:BMAX")
  field(DOL2, "LGPS:UNDH:2:BMAX")
  field(DOL3, "LGPS:UNDH:2:BMAX")
  field(DOL4, "LGPS:UNDH:2:BMIN")
  field(DOL5, "LGPS:UNDH:2:BMIN")
  field(DOL6, "LGPS:UNDH:2:BMIN")
  field(LNK1, "LGPS:UNDH:2:BMAGX.HOPR")
  field(LNK2, "LGPS:UNDH:2:BMAGY.HOPR")
  field(LNK3, "LGPS:UNDH:2:BLEM.HOPR")
  field(LNK4, "LGPS:UNDH:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:UNDH:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:UNDH:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:UNDH:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:UNDH:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:UNDH:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:UNDH:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:UNDH:2:EDES NPP MS")
  field(INPB, "LGPS:UNDH:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:UNDH:3:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "LGPS:UNDH:3:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:UNDH:3:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:UNDH:3:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:UNDH:3:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:UNDH:3:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:UNDH:3:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:UNDH:3:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:UNDH:3:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:UNDH:3:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:UNDH:3:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:UNDH:3:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:UNDH:3:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:UNDH:3:EDES.PROC PP")
    field(LNK2, "LGPS:UNDH:3:EACT.PROC PP")
    field(LNK3, "LGPS:UNDH:3:EERR.DISA PP")
    field(LNK4, "LGPS:UNDH:3:ECON.PROC PP")
    field(LNK5, "LGPS:UNDH:3:BMAGX.PROC PP")
    field(LNK6, "LGPS:UNDH:3:BMAGY.PROC PP")
    field(LNK7, "LGPS:UNDH:3:BLEM.PROC PP")
    field(LNK8, "LGPS:UNDH:3:BMOD.PROC PP")
    field(LNK9, "LGPS:UNDH:3:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:UNDH:3:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:UNDH:3:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:UNDH:3:BMAX")
  field(DOL2, "LGPS:UNDH:3:BMAX")
  field(DOL3, "LGPS:UNDH:3:BMAX")
  field(DOL4, "LGPS:UNDH:3:BMIN")
  field(DOL5, "LGPS:UNDH:3:BMIN")
  field(DOL6, "LGPS:UNDH:3:BMIN")
  field(LNK1, "LGPS:UNDH:3:BMAGX.HOPR")
  field(LNK2, "LGPS:UNDH:3:BMAGY.HOPR")
  field(LNK3, "LGPS:UNDH:3:BLEM.HOPR")
  field(LNK4, "LGPS:UNDH:3:BMAGX.LOPR PP")
  field(LNK5, "LGPS:UNDH:3:BMAGY.LOPR PP")
  field(LNK6, "LGPS:UNDH:3:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:3:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:3:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:UNDH:3:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:UNDH:3:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:UNDH:3:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:3:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:3:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:3:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:3:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:3:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:UNDH:3:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:UNDH:3:EDES NPP MS")
  field(INPB, "LGPS:UNDH:3:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:UNDH:4:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "LGPS:UNDH:4:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:UNDH:4:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:UNDH:4:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:UNDH:4:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:UNDH:4:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:UNDH:4:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:UNDH:4:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:UNDH:4:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:UNDH:4:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:UNDH:4:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:UNDH:4:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:UNDH:4:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:UNDH:4:EDES.PROC PP")
    field(LNK2, "LGPS:UNDH:4:EACT.PROC PP")
    field(LNK3, "LGPS:UNDH:4:EERR.DISA PP")
    field(LNK4, "LGPS:UNDH:4:ECON.PROC PP")
    field(LNK5, "LGPS:UNDH:4:BMAGX.PROC PP")
    field(LNK6, "LGPS:UNDH:4:BMAGY.PROC PP")
    field(LNK7, "LGPS:UNDH:4:BLEM.PROC PP")
    field(LNK8, "LGPS:UNDH:4:BMOD.PROC PP")
    field(LNK9, "LGPS:UNDH:4:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:UNDH:4:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:UNDH:4:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:UNDH:4:BMAX")
  field(DOL2, "LGPS:UNDH:4:BMAX")
  field(DOL3, "LGPS:UNDH:4:BMAX")
  field(DOL4, "LGPS:UNDH:4:BMIN")
  field(DOL5, "LGPS:UNDH:4:BMIN")
  field(DOL6, "LGPS:UNDH:4:BMIN")
  field(LNK1, "LGPS:UNDH:4:BMAGX.HOPR")
  field(LNK2, "LGPS:UNDH:4:BMAGY.HOPR")
  field(LNK3, "LGPS:UNDH:4:BLEM.HOPR")
  field(LNK4, "LGPS:UNDH:4:BMAGX.LOPR PP")
  field(LNK5, "LGPS:UNDH:4:BMAGY.LOPR PP")
  field(LNK6, "LGPS:UNDH:4:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:4:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:4:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:UNDH:4:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:UNDH:4:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:UNDH:4:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:4:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:4:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:4:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:4:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:4:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:UNDH:4:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:UNDH:4:EDES NPP MS")
  field(INPB, "LGPS:UNDH:4:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:UNDH:5:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "LGPS:UNDH:5:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:UNDH:5:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:UNDH:5:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:UNDH:5:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:UNDH:5:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:UNDH:5:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:UNDH:5:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:UNDH:5:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:UNDH:5:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:UNDH:5:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:UNDH:5:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:UNDH:5:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:UNDH:5:EDES.PROC PP")
    field(LNK2, "LGPS:UNDH:5:EACT.PROC PP")
    field(LNK3, "LGPS:UNDH:5:EERR.DISA PP")
    field(LNK4, "LGPS:UNDH:5:ECON.PROC PP")
    field(LNK5, "LGPS:UNDH:5:BMAGX.PROC PP")
    field(LNK6, "LGPS:UNDH:5:BMAGY.PROC PP")
    field(LNK7, "LGPS:UNDH:5:BLEM.PROC PP")
    field(LNK8, "LGPS:UNDH:5:BMOD.PROC PP")
    field(LNK9, "LGPS:UNDH:5:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:UNDH:5:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:UNDH:5:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:UNDH:5:BMAX")
  field(DOL2, "LGPS:UNDH:5:BMAX")
  field(DOL3, "LGPS:UNDH:5:BMAX")
  field(DOL4, "LGPS:UNDH:5:BMIN")
  field(DOL5, "LGPS:UNDH:5:BMIN")
  field(DOL6, "LGPS:UNDH:5:BMIN")
  field(LNK1, "LGPS:UNDH:5:BMAGX.HOPR")
  field(LNK2, "LGPS:UNDH:5:BMAGY.HOPR")
  field(LNK3, "LGPS:UNDH:5:BLEM.HOPR")
  field(LNK4, "LGPS:UNDH:5:BMAGX.LOPR PP")
  field(LNK5, "LGPS:UNDH:5:BMAGY.LOPR PP")
  field(LNK6, "LGPS:UNDH:5:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:5:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:5:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:UNDH:5:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:UNDH:5:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:UNDH:5:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:5:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:5:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:5:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:5:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:5:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:UNDH:5:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:UNDH:5:EDES NPP MS")
  field(INPB, "LGPS:UNDH:5:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:UNDH:6:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "LGPS:UNDH:6:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:UNDH:6:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:UNDH:6:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:UNDH:6:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:UNDH:6:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:UNDH:6:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:UNDH:6:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:UNDH:6:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:UNDH:6:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:UNDH:6:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:UNDH:6:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:UNDH:6:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:UNDH:6:EDES.PROC PP")
    field(LNK2, "LGPS:UNDH:6:EACT.PROC PP")
    field(LNK3, "LGPS:UNDH:6:EERR.DISA PP")
    field(LNK4, "LGPS:UNDH:6:ECON.PROC PP")
    field(LNK5, "LGPS:UNDH:6:BMAGX.PROC PP")
    field(LNK6, "LGPS:UNDH:6:BMAGY.PROC PP")
    field(LNK7, "LGPS:UNDH:6:BLEM.PROC PP")
    field(LNK8, "LGPS:UNDH:6:BMOD.PROC PP")
    field(LNK9, "LGPS:UNDH:6:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:UNDH:6:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:UNDH:6:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:UNDH:6:BMAX")
  field(DOL2, "LGPS:UNDH:6:BMAX")
  field(DOL3, "LGPS:UNDH:6:BMAX")
  field(DOL4, "LGPS:UNDH:6:BMIN")
  field(DOL5, "LGPS:UNDH:6:BMIN")
  field(DOL6, "LGPS:UNDH:6:BMIN")
  field(LNK1, "LGPS:UNDH:6:BMAGX.HOPR")
  field(LNK2, "LGPS:UNDH:6:BMAGY.HOPR")
  field(LNK3, "LGPS:UNDH:6:BLEM.HOPR")
  field(LNK4, "LGPS:UNDH:6:BMAGX.LOPR PP")
  field(LNK5, "LGPS:UNDH:6:BMAGY.LOPR PP")
  field(LNK6, "LGPS:UNDH:6:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:6:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:6:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:UNDH:6:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:UNDH:6:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:UNDH:6:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:6:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:6:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:6:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:6:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:6:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:UNDH:6:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:UNDH:6:EDES NPP MS")
  field(INPB, "LGPS:UNDH:6:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:UNDH:7:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "LGPS:UNDH:7:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:UNDH:7:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:UNDH:7:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:UNDH:7:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:UNDH:7:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:UNDH:7:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:UNDH:7:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:UNDH:7:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:UNDH:7:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:UNDH:7:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:UNDH:7:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:UNDH:7:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:UNDH:7:EDES.PROC PP")
    field(LNK2, "LGPS:UNDH:7:EACT.PROC PP")
    field(LNK3, "LGPS:UNDH:7:EERR.DISA PP")
    field(LNK4, "LGPS:UNDH:7:ECON.PROC PP")
    field(LNK5, "LGPS:UNDH:7:BMAGX.PROC PP")
    field(LNK6, "LGPS:UNDH:7:BMAGY.PROC PP")
    field(LNK7, "LGPS:UNDH:7:BLEM.PROC PP")
    field(LNK8, "LGPS:UNDH:7:BMOD.PROC PP")
    field(LNK9, "LGPS:UNDH:7:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:UNDH:7:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:UNDH:7:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:UNDH:7:BMAX")
  field(DOL2, "LGPS:UNDH:7:BMAX")
  field(DOL3, "LGPS:UNDH:7:BMAX")
  field(DOL4, "LGPS:UNDH:7:BMIN")
  field(DOL5, "LGPS:UNDH:7:BMIN")
  field(DOL6, "LGPS:UNDH:7:BMIN")
  field(LNK1, "LGPS:UNDH:7:BMAGX.HOPR")
  field(LNK2, "LGPS:UNDH:7:BMAGY.HOPR")
  field(LNK3, "LGPS:UNDH:7:BLEM.HOPR")
  field(LNK4, "LGPS:UNDH:7:BMAGX.LOPR PP")
  field(LNK5, "LGPS:UNDH:7:BMAGY.LOPR PP")
  field(LNK6, "LGPS:UNDH:7:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:7:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:7:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:UNDH:7:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:UNDH:7:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:UNDH:7:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:7:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:7:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:7:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:7:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:7:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:UNDH:7:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:UNDH:7:EDES NPP MS")
  field(INPB, "LGPS:UNDH:7:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:UNDH:8:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "LGPS:UNDH:8:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:UNDH:8:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:UNDH:8:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:UNDH:8:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:UNDH:8:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:UNDH:8:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:UNDH:8:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:UNDH:8:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:UNDH:8:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:UNDH:8:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:UNDH:8:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:UNDH:8:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:UNDH:8:EDES.PROC PP")
    field(LNK2, "LGPS:UNDH:8:EACT.PROC PP")
    field(LNK3, "LGPS:UNDH:8:EERR.DISA PP")
    field(LNK4, "LGPS:UNDH:8:ECON.PROC PP")
    field(LNK5, "LGPS:UNDH:8:BMAGX.PROC PP")
    field(LNK6, "LGPS:UNDH:8:BMAGY.PROC PP")
    field(LNK7, "LGPS:UNDH:8:BLEM.PROC PP")
    field(LNK8, "LGPS:UNDH:8:BMOD.PROC PP")
    field(LNK9, "LGPS:UNDH:8:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:UNDH:8:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:UNDH:8:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:UNDH:8:BMAX")
  field(DOL2, "LGPS:UNDH:8:BMAX")
  field(DOL3, "LGPS:UNDH:8:BMAX")
  field(DOL4, "LGPS:UNDH:8:BMIN")
  field(DOL5, "LGPS:UNDH:8:BMIN")
  field(DOL6, "LGPS:UNDH:8:BMIN")
  field(LNK1, "LGPS:UNDH:8:BMAGX.HOPR")
  field(LNK2, "LGPS:UNDH:8:BMAGY.HOPR")
  field(LNK3, "LGPS:UNDH:8:BLEM.HOPR")
  field(LNK4, "LGPS:UNDH:8:BMAGX.LOPR PP")
  field(LNK5, "LGPS:UNDH:8:BMAGY.LOPR PP")
  field(LNK6, "LGPS:UNDH:8:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:8:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDH:8:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:UNDH:8:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:UNDH:8:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:UNDH:8:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:8:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:8:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:8:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDH:8:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDH:8:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:UNDH:8:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:UNDH:8:EDES NPP MS")
  field(INPB, "LGPS:UNDH:8:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDH:1330:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDH:1330:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDH:1330:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDH:1330:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDH:1330:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDH:1330:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDH:1330:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDH:1330:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDH:1330:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDH:1330:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDH:1330:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDH:1330:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDH:1330:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDH:1330:EDES.PROC PP")
    field(LNK2, "BEND:UNDH:1330:EACT.PROC PP")
    field(LNK3, "BEND:UNDH:1330:EERR.DISA PP")
    field(LNK4, "BEND:UNDH:1330:ECON.PROC PP")
    field(LNK5, "BEND:UNDH:1330:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDH:1330:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDH:1330:BLEM.PROC PP")
    field(LNK8, "BEND:UNDH:1330:BMOD.PROC PP")
    field(LNK9, "BEND:UNDH:1330:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDH:1330:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDH:1330:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDH:1330:BMAX")
  field(DOL2, "BEND:UNDH:1330:BMAX")
  field(DOL3, "BEND:UNDH:1330:BMAX")
  field(DOL4, "BEND:UNDH:1330:BMIN")
  field(DOL5, "BEND:UNDH:1330:BMIN")
  field(DOL6, "BEND:UNDH:1330:BMIN")
  field(LNK1, "BEND:UNDH:1330:BMAGX.HOPR")
  field(LNK2, "BEND:UNDH:1330:BMAGY.HOPR")
  field(LNK3, "BEND:UNDH:1330:BLEM.HOPR")
  field(LNK4, "BEND:UNDH:1330:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDH:1330:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDH:1330:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:1330:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:1330:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDH:1330:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDH:1330:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDH:1330:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:1330:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:1330:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:UNDH:1330:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:1330:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:UNDH:1330:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDH:1330:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDH:1330:EDES NPP MS")
  field(INPB, "BEND:UNDH:1330:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDH:2130:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDH:2130:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDH:2130:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDH:2130:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDH:2130:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDH:2130:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDH:2130:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDH:2130:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDH:2130:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDH:2130:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDH:2130:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDH:2130:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDH:2130:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDH:2130:EDES.PROC PP")
    field(LNK2, "BEND:UNDH:2130:EACT.PROC PP")
    field(LNK3, "BEND:UNDH:2130:EERR.DISA PP")
    field(LNK4, "BEND:UNDH:2130:ECON.PROC PP")
    field(LNK5, "BEND:UNDH:2130:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDH:2130:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDH:2130:BLEM.PROC PP")
    field(LNK8, "BEND:UNDH:2130:BMOD.PROC PP")
    field(LNK9, "BEND:UNDH:2130:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDH:2130:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDH:2130:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDH:2130:BMAX")
  field(DOL2, "BEND:UNDH:2130:BMAX")
  field(DOL3, "BEND:UNDH:2130:BMAX")
  field(DOL4, "BEND:UNDH:2130:BMIN")
  field(DOL5, "BEND:UNDH:2130:BMIN")
  field(DOL6, "BEND:UNDH:2130:BMIN")
  field(LNK1, "BEND:UNDH:2130:BMAGX.HOPR")
  field(LNK2, "BEND:UNDH:2130:BMAGY.HOPR")
  field(LNK3, "BEND:UNDH:2130:BLEM.HOPR")
  field(LNK4, "BEND:UNDH:2130:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDH:2130:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDH:2130:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2130:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2130:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDH:2130:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDH:2130:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDH:2130:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2130:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2130:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:UNDH:2130:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2130:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:UNDH:2130:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDH:2130:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDH:2130:EDES NPP MS")
  field(INPB, "BEND:UNDH:2130:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDH:2810:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDH:2810:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDH:2810:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDH:2810:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDH:2810:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDH:2810:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDH:2810:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDH:2810:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDH:2810:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDH:2810:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDH:2810:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDH:2810:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDH:2810:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDH:2810:EDES.PROC PP")
    field(LNK2, "BEND:UNDH:2810:EACT.PROC PP")
    field(LNK3, "BEND:UNDH:2810:EERR.DISA PP")
    field(LNK4, "BEND:UNDH:2810:ECON.PROC PP")
    field(LNK5, "BEND:UNDH:2810:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDH:2810:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDH:2810:BLEM.PROC PP")
    field(LNK8, "BEND:UNDH:2810:BMOD.PROC PP")
    field(LNK9, "BEND:UNDH:2810:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDH:2810:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDH:2810:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDH:2810:BMAX")
  field(DOL2, "BEND:UNDH:2810:BMAX")
  field(DOL3, "BEND:UNDH:2810:BMAX")
  field(DOL4, "BEND:UNDH:2810:BMIN")
  field(DOL5, "BEND:UNDH:2810:BMIN")
  field(DOL6, "BEND:UNDH:2810:BMIN")
  field(LNK1, "BEND:UNDH:2810:BMAGX.HOPR")
  field(LNK2, "BEND:UNDH:2810:BMAGY.HOPR")
  field(LNK3, "BEND:UNDH:2810:BLEM.HOPR")
  field(LNK4, "BEND:UNDH:2810:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDH:2810:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDH:2810:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2810:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2810:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDH:2810:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDH:2810:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDH:2810:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2810:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2810:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:UNDH:2810:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2810:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:UNDH:2810:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDH:2810:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDH:2810:EDES NPP MS")
  field(INPB, "BEND:UNDH:2810:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDH:1330:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDH:1330:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDH:1330:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDH:1330:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDH:1330:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDH:1330:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDH:1330:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDH:1330:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDH:1330:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDH:1330:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDH:1330:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDH:1330:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDH:1330:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDH:1330:EDES.PROC PP")
    field(LNK2, "BTRM:UNDH:1330:EACT.PROC PP")
    field(LNK3, "BTRM:UNDH:1330:EERR.DISA PP")
    field(LNK4, "BTRM:UNDH:1330:ECON.PROC PP")
    field(LNK5, "BTRM:UNDH:1330:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDH:1330:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDH:1330:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDH:1330:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDH:1330:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDH:1330:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDH:1330:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDH:1330:BMAX")
  field(DOL2, "BTRM:UNDH:1330:BMAX")
  field(DOL3, "BTRM:UNDH:1330:BMAX")
  field(DOL4, "BTRM:UNDH:1330:BMIN")
  field(DOL5, "BTRM:UNDH:1330:BMIN")
  field(DOL6, "BTRM:UNDH:1330:BMIN")
  field(LNK1, "BTRM:UNDH:1330:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDH:1330:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDH:1330:BLEM.HOPR")
  field(LNK4, "BTRM:UNDH:1330:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDH:1330:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDH:1330:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:1330:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:1330:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDH:1330:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDH:1330:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDH:1330:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:1330:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:1330:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:1330:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:1330:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:1330:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDH:1330:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDH:1330:EDES NPP MS")
  field(INPB, "BTRM:UNDH:1330:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDH:1355:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDH:1355:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDH:1355:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDH:1355:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDH:1355:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDH:1355:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDH:1355:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDH:1355:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDH:1355:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDH:1355:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDH:1355:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDH:1355:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDH:1355:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDH:1355:EDES.PROC PP")
    field(LNK2, "BTRM:UNDH:1355:EACT.PROC PP")
    field(LNK3, "BTRM:UNDH:1355:EERR.DISA PP")
    field(LNK4, "BTRM:UNDH:1355:ECON.PROC PP")
    field(LNK5, "BTRM:UNDH:1355:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDH:1355:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDH:1355:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDH:1355:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDH:1355:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDH:1355:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDH:1355:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDH:1355:BMAX")
  field(DOL2, "BTRM:UNDH:1355:BMAX")
  field(DOL3, "BTRM:UNDH:1355:BMAX")
  field(DOL4, "BTRM:UNDH:1355:BMIN")
  field(DOL5, "BTRM:UNDH:1355:BMIN")
  field(DOL6, "BTRM:UNDH:1355:BMIN")
  field(LNK1, "BTRM:UNDH:1355:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDH:1355:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDH:1355:BLEM.HOPR")
  field(LNK4, "BTRM:UNDH:1355:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDH:1355:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDH:1355:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:1355:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:1355:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDH:1355:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDH:1355:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDH:1355:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:1355:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:1355:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:1355:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:1355:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:1355:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDH:1355:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDH:1355:EDES NPP MS")
  field(INPB, "BTRM:UNDH:1355:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDH:1360:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDH:1360:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDH:1360:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDH:1360:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDH:1360:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDH:1360:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDH:1360:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDH:1360:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDH:1360:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDH:1360:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDH:1360:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDH:1360:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDH:1360:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDH:1360:EDES.PROC PP")
    field(LNK2, "BTRM:UNDH:1360:EACT.PROC PP")
    field(LNK3, "BTRM:UNDH:1360:EERR.DISA PP")
    field(LNK4, "BTRM:UNDH:1360:ECON.PROC PP")
    field(LNK5, "BTRM:UNDH:1360:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDH:1360:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDH:1360:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDH:1360:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDH:1360:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDH:1360:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDH:1360:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDH:1360:BMAX")
  field(DOL2, "BTRM:UNDH:1360:BMAX")
  field(DOL3, "BTRM:UNDH:1360:BMAX")
  field(DOL4, "BTRM:UNDH:1360:BMIN")
  field(DOL5, "BTRM:UNDH:1360:BMIN")
  field(DOL6, "BTRM:UNDH:1360:BMIN")
  field(LNK1, "BTRM:UNDH:1360:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDH:1360:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDH:1360:BLEM.HOPR")
  field(LNK4, "BTRM:UNDH:1360:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDH:1360:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDH:1360:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:1360:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:1360:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDH:1360:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDH:1360:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDH:1360:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:1360:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:1360:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:1360:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:1360:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:1360:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDH:1360:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDH:1360:EDES NPP MS")
  field(INPB, "BTRM:UNDH:1360:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDH:1375:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDH:1375:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDH:1375:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDH:1375:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDH:1375:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDH:1375:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDH:1375:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDH:1375:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDH:1375:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDH:1375:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDH:1375:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDH:1375:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDH:1375:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDH:1375:EDES.PROC PP")
    field(LNK2, "BTRM:UNDH:1375:EACT.PROC PP")
    field(LNK3, "BTRM:UNDH:1375:EERR.DISA PP")
    field(LNK4, "BTRM:UNDH:1375:ECON.PROC PP")
    field(LNK5, "BTRM:UNDH:1375:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDH:1375:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDH:1375:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDH:1375:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDH:1375:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDH:1375:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDH:1375:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDH:1375:BMAX")
  field(DOL2, "BTRM:UNDH:1375:BMAX")
  field(DOL3, "BTRM:UNDH:1375:BMAX")
  field(DOL4, "BTRM:UNDH:1375:BMIN")
  field(DOL5, "BTRM:UNDH:1375:BMIN")
  field(DOL6, "BTRM:UNDH:1375:BMIN")
  field(LNK1, "BTRM:UNDH:1375:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDH:1375:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDH:1375:BLEM.HOPR")
  field(LNK4, "BTRM:UNDH:1375:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDH:1375:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDH:1375:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:1375:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:1375:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDH:1375:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDH:1375:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDH:1375:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:1375:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:1375:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:1375:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:1375:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:1375:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDH:1375:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDH:1375:EDES NPP MS")
  field(INPB, "BTRM:UNDH:1375:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDH:2130:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDH:2130:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDH:2130:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDH:2130:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDH:2130:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDH:2130:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDH:2130:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDH:2130:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDH:2130:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDH:2130:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDH:2130:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDH:2130:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDH:2130:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDH:2130:EDES.PROC PP")
    field(LNK2, "BTRM:UNDH:2130:EACT.PROC PP")
    field(LNK3, "BTRM:UNDH:2130:EERR.DISA PP")
    field(LNK4, "BTRM:UNDH:2130:ECON.PROC PP")
    field(LNK5, "BTRM:UNDH:2130:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDH:2130:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDH:2130:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDH:2130:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDH:2130:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDH:2130:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDH:2130:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDH:2130:BMAX")
  field(DOL2, "BTRM:UNDH:2130:BMAX")
  field(DOL3, "BTRM:UNDH:2130:BMAX")
  field(DOL4, "BTRM:UNDH:2130:BMIN")
  field(DOL5, "BTRM:UNDH:2130:BMIN")
  field(DOL6, "BTRM:UNDH:2130:BMIN")
  field(LNK1, "BTRM:UNDH:2130:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDH:2130:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDH:2130:BLEM.HOPR")
  field(LNK4, "BTRM:UNDH:2130:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDH:2130:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDH:2130:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2130:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2130:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDH:2130:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDH:2130:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDH:2130:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2130:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2130:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2130:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2130:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2130:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDH:2130:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDH:2130:EDES NPP MS")
  field(INPB, "BTRM:UNDH:2130:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDH:2155:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDH:2155:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDH:2155:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDH:2155:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDH:2155:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDH:2155:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDH:2155:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDH:2155:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDH:2155:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDH:2155:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDH:2155:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDH:2155:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDH:2155:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDH:2155:EDES.PROC PP")
    field(LNK2, "BTRM:UNDH:2155:EACT.PROC PP")
    field(LNK3, "BTRM:UNDH:2155:EERR.DISA PP")
    field(LNK4, "BTRM:UNDH:2155:ECON.PROC PP")
    field(LNK5, "BTRM:UNDH:2155:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDH:2155:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDH:2155:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDH:2155:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDH:2155:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDH:2155:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDH:2155:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDH:2155:BMAX")
  field(DOL2, "BTRM:UNDH:2155:BMAX")
  field(DOL3, "BTRM:UNDH:2155:BMAX")
  field(DOL4, "BTRM:UNDH:2155:BMIN")
  field(DOL5, "BTRM:UNDH:2155:BMIN")
  field(DOL6, "BTRM:UNDH:2155:BMIN")
  field(LNK1, "BTRM:UNDH:2155:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDH:2155:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDH:2155:BLEM.HOPR")
  field(LNK4, "BTRM:UNDH:2155:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDH:2155:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDH:2155:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2155:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2155:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDH:2155:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDH:2155:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDH:2155:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2155:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2155:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2155:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2155:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2155:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDH:2155:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDH:2155:EDES NPP MS")
  field(INPB, "BTRM:UNDH:2155:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDH:2160:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDH:2160:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDH:2160:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDH:2160:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDH:2160:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDH:2160:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDH:2160:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDH:2160:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDH:2160:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDH:2160:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDH:2160:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDH:2160:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDH:2160:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDH:2160:EDES.PROC PP")
    field(LNK2, "BTRM:UNDH:2160:EACT.PROC PP")
    field(LNK3, "BTRM:UNDH:2160:EERR.DISA PP")
    field(LNK4, "BTRM:UNDH:2160:ECON.PROC PP")
    field(LNK5, "BTRM:UNDH:2160:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDH:2160:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDH:2160:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDH:2160:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDH:2160:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDH:2160:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDH:2160:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDH:2160:BMAX")
  field(DOL2, "BTRM:UNDH:2160:BMAX")
  field(DOL3, "BTRM:UNDH:2160:BMAX")
  field(DOL4, "BTRM:UNDH:2160:BMIN")
  field(DOL5, "BTRM:UNDH:2160:BMIN")
  field(DOL6, "BTRM:UNDH:2160:BMIN")
  field(LNK1, "BTRM:UNDH:2160:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDH:2160:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDH:2160:BLEM.HOPR")
  field(LNK4, "BTRM:UNDH:2160:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDH:2160:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDH:2160:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2160:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2160:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDH:2160:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDH:2160:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDH:2160:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2160:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2160:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2160:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2160:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2160:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDH:2160:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDH:2160:EDES NPP MS")
  field(INPB, "BTRM:UNDH:2160:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDH:2175:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDH:2175:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDH:2175:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDH:2175:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDH:2175:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDH:2175:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDH:2175:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDH:2175:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDH:2175:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDH:2175:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDH:2175:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDH:2175:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDH:2175:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDH:2175:EDES.PROC PP")
    field(LNK2, "BTRM:UNDH:2175:EACT.PROC PP")
    field(LNK3, "BTRM:UNDH:2175:EERR.DISA PP")
    field(LNK4, "BTRM:UNDH:2175:ECON.PROC PP")
    field(LNK5, "BTRM:UNDH:2175:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDH:2175:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDH:2175:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDH:2175:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDH:2175:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDH:2175:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDH:2175:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDH:2175:BMAX")
  field(DOL2, "BTRM:UNDH:2175:BMAX")
  field(DOL3, "BTRM:UNDH:2175:BMAX")
  field(DOL4, "BTRM:UNDH:2175:BMIN")
  field(DOL5, "BTRM:UNDH:2175:BMIN")
  field(DOL6, "BTRM:UNDH:2175:BMIN")
  field(LNK1, "BTRM:UNDH:2175:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDH:2175:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDH:2175:BLEM.HOPR")
  field(LNK4, "BTRM:UNDH:2175:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDH:2175:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDH:2175:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2175:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2175:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDH:2175:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDH:2175:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDH:2175:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2175:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2175:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2175:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2175:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2175:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDH:2175:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDH:2175:EDES NPP MS")
  field(INPB, "BTRM:UNDH:2175:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDH:2810:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDH:2810:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDH:2810:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDH:2810:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDH:2810:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDH:2810:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDH:2810:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDH:2810:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDH:2810:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDH:2810:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDH:2810:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDH:2810:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDH:2810:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDH:2810:EDES.PROC PP")
    field(LNK2, "BTRM:UNDH:2810:EACT.PROC PP")
    field(LNK3, "BTRM:UNDH:2810:EERR.DISA PP")
    field(LNK4, "BTRM:UNDH:2810:ECON.PROC PP")
    field(LNK5, "BTRM:UNDH:2810:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDH:2810:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDH:2810:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDH:2810:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDH:2810:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDH:2810:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDH:2810:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDH:2810:BMAX")
  field(DOL2, "BTRM:UNDH:2810:BMAX")
  field(DOL3, "BTRM:UNDH:2810:BMAX")
  field(DOL4, "BTRM:UNDH:2810:BMIN")
  field(DOL5, "BTRM:UNDH:2810:BMIN")
  field(DOL6, "BTRM:UNDH:2810:BMIN")
  field(LNK1, "BTRM:UNDH:2810:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDH:2810:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDH:2810:BLEM.HOPR")
  field(LNK4, "BTRM:UNDH:2810:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDH:2810:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDH:2810:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2810:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2810:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDH:2810:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDH:2810:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDH:2810:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2810:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2810:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2810:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2810:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2810:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDH:2810:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDH:2810:EDES NPP MS")
  field(INPB, "BTRM:UNDH:2810:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDH:2830:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDH:2830:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDH:2830:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDH:2830:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDH:2830:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDH:2830:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDH:2830:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDH:2830:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDH:2830:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDH:2830:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDH:2830:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDH:2830:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDH:2830:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDH:2830:EDES.PROC PP")
    field(LNK2, "BTRM:UNDH:2830:EACT.PROC PP")
    field(LNK3, "BTRM:UNDH:2830:EERR.DISA PP")
    field(LNK4, "BTRM:UNDH:2830:ECON.PROC PP")
    field(LNK5, "BTRM:UNDH:2830:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDH:2830:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDH:2830:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDH:2830:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDH:2830:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDH:2830:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDH:2830:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDH:2830:BMAX")
  field(DOL2, "BTRM:UNDH:2830:BMAX")
  field(DOL3, "BTRM:UNDH:2830:BMAX")
  field(DOL4, "BTRM:UNDH:2830:BMIN")
  field(DOL5, "BTRM:UNDH:2830:BMIN")
  field(DOL6, "BTRM:UNDH:2830:BMIN")
  field(LNK1, "BTRM:UNDH:2830:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDH:2830:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDH:2830:BLEM.HOPR")
  field(LNK4, "BTRM:UNDH:2830:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDH:2830:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDH:2830:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2830:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2830:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDH:2830:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDH:2830:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDH:2830:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2830:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2830:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2830:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2830:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2830:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDH:2830:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDH:2830:EDES NPP MS")
  field(INPB, "BTRM:UNDH:2830:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDH:2850:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDH:2850:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDH:2850:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDH:2850:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDH:2850:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDH:2850:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDH:2850:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDH:2850:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDH:2850:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDH:2850:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDH:2850:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDH:2850:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDH:2850:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDH:2850:EDES.PROC PP")
    field(LNK2, "BTRM:UNDH:2850:EACT.PROC PP")
    field(LNK3, "BTRM:UNDH:2850:EERR.DISA PP")
    field(LNK4, "BTRM:UNDH:2850:ECON.PROC PP")
    field(LNK5, "BTRM:UNDH:2850:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDH:2850:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDH:2850:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDH:2850:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDH:2850:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDH:2850:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDH:2850:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDH:2850:BMAX")
  field(DOL2, "BTRM:UNDH:2850:BMAX")
  field(DOL3, "BTRM:UNDH:2850:BMAX")
  field(DOL4, "BTRM:UNDH:2850:BMIN")
  field(DOL5, "BTRM:UNDH:2850:BMIN")
  field(DOL6, "BTRM:UNDH:2850:BMIN")
  field(LNK1, "BTRM:UNDH:2850:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDH:2850:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDH:2850:BLEM.HOPR")
  field(LNK4, "BTRM:UNDH:2850:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDH:2850:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDH:2850:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2850:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2850:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDH:2850:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDH:2850:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDH:2850:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2850:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2850:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2850:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2850:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2850:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDH:2850:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDH:2850:EDES NPP MS")
  field(INPB, "BTRM:UNDH:2850:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDH:2870:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDH:2870:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDH:2870:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDH:2870:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDH:2870:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDH:2870:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDH:2870:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDH:2870:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDH:2870:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDH:2870:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDH:2870:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDH:2870:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDH:2870:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDH:2870:EDES.PROC PP")
    field(LNK2, "BTRM:UNDH:2870:EACT.PROC PP")
    field(LNK3, "BTRM:UNDH:2870:EERR.DISA PP")
    field(LNK4, "BTRM:UNDH:2870:ECON.PROC PP")
    field(LNK5, "BTRM:UNDH:2870:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDH:2870:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDH:2870:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDH:2870:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDH:2870:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDH:2870:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDH:2870:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDH:2870:BMAX")
  field(DOL2, "BTRM:UNDH:2870:BMAX")
  field(DOL3, "BTRM:UNDH:2870:BMAX")
  field(DOL4, "BTRM:UNDH:2870:BMIN")
  field(DOL5, "BTRM:UNDH:2870:BMIN")
  field(DOL6, "BTRM:UNDH:2870:BMIN")
  field(LNK1, "BTRM:UNDH:2870:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDH:2870:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDH:2870:BLEM.HOPR")
  field(LNK4, "BTRM:UNDH:2870:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDH:2870:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDH:2870:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2870:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDH:2870:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDH:2870:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDH:2870:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDH:2870:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2870:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2870:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2870:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDH:2870:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDH:2870:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDH:2870:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDH:2870:EDES NPP MS")
  field(INPB, "BTRM:UNDH:2870:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:1380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:1380:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:1380:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:1380:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:1380:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:1380:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:1380:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:1380:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:1380:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:1380:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:1380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:1380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:1380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:1380:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:1380:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:1380:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:1380:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:1380:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:1380:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:1380:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:1380:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:1380:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:1380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:1380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:1380:BMAX")
  field(DOL2, "QUAD:UNDH:1380:BMAX")
  field(DOL3, "QUAD:UNDH:1380:BMAX")
  field(DOL4, "QUAD:UNDH:1380:BMIN")
  field(DOL5, "QUAD:UNDH:1380:BMIN")
  field(DOL6, "QUAD:UNDH:1380:BMIN")
  field(LNK1, "QUAD:UNDH:1380:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:1380:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:1380:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:1380:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:1380:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:1380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:1380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:1380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:1380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:1380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:1380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:1380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:1380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:1380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:1380:EDES NPP MS")
  field(INPB, "QUAD:UNDH:1380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:1480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:1480:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:1480:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:1480:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:1480:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:1480:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:1480:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:1480:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:1480:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:1480:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:1480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:1480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:1480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:1480:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:1480:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:1480:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:1480:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:1480:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:1480:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:1480:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:1480:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:1480:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:1480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:1480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:1480:BMAX")
  field(DOL2, "QUAD:UNDH:1480:BMAX")
  field(DOL3, "QUAD:UNDH:1480:BMAX")
  field(DOL4, "QUAD:UNDH:1480:BMIN")
  field(DOL5, "QUAD:UNDH:1480:BMIN")
  field(DOL6, "QUAD:UNDH:1480:BMIN")
  field(LNK1, "QUAD:UNDH:1480:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:1480:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:1480:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:1480:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:1480:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:1480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:1480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:1480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:1480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:1480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:1480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:1480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:1480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:1480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:1480:EDES NPP MS")
  field(INPB, "QUAD:UNDH:1480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:1580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:1580:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:1580:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:1580:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:1580:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:1580:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:1580:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:1580:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:1580:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:1580:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:1580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:1580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:1580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:1580:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:1580:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:1580:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:1580:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:1580:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:1580:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:1580:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:1580:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:1580:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:1580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:1580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:1580:BMAX")
  field(DOL2, "QUAD:UNDH:1580:BMAX")
  field(DOL3, "QUAD:UNDH:1580:BMAX")
  field(DOL4, "QUAD:UNDH:1580:BMIN")
  field(DOL5, "QUAD:UNDH:1580:BMIN")
  field(DOL6, "QUAD:UNDH:1580:BMIN")
  field(LNK1, "QUAD:UNDH:1580:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:1580:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:1580:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:1580:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:1580:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:1580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:1580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:1580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:1580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:1580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:1580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:1580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:1580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:1580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:1580:EDES NPP MS")
  field(INPB, "QUAD:UNDH:1580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:1680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:1680:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:1680:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:1680:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:1680:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:1680:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:1680:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:1680:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:1680:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:1680:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:1680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:1680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:1680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:1680:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:1680:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:1680:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:1680:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:1680:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:1680:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:1680:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:1680:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:1680:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:1680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:1680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:1680:BMAX")
  field(DOL2, "QUAD:UNDH:1680:BMAX")
  field(DOL3, "QUAD:UNDH:1680:BMAX")
  field(DOL4, "QUAD:UNDH:1680:BMIN")
  field(DOL5, "QUAD:UNDH:1680:BMIN")
  field(DOL6, "QUAD:UNDH:1680:BMIN")
  field(LNK1, "QUAD:UNDH:1680:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:1680:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:1680:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:1680:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:1680:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:1680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:1680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:1680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:1680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:1680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:1680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:1680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:1680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:1680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:1680:EDES NPP MS")
  field(INPB, "QUAD:UNDH:1680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:1780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:1780:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:1780:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:1780:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:1780:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:1780:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:1780:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:1780:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:1780:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:1780:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:1780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:1780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:1780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:1780:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:1780:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:1780:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:1780:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:1780:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:1780:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:1780:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:1780:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:1780:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:1780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:1780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:1780:BMAX")
  field(DOL2, "QUAD:UNDH:1780:BMAX")
  field(DOL3, "QUAD:UNDH:1780:BMAX")
  field(DOL4, "QUAD:UNDH:1780:BMIN")
  field(DOL5, "QUAD:UNDH:1780:BMIN")
  field(DOL6, "QUAD:UNDH:1780:BMIN")
  field(LNK1, "QUAD:UNDH:1780:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:1780:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:1780:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:1780:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:1780:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:1780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:1780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:1780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:1780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:1780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:1780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:1780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:1780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:1780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:1780:EDES NPP MS")
  field(INPB, "QUAD:UNDH:1780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:1880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:1880:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:1880:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:1880:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:1880:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:1880:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:1880:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:1880:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:1880:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:1880:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:1880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:1880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:1880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:1880:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:1880:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:1880:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:1880:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:1880:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:1880:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:1880:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:1880:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:1880:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:1880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:1880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:1880:BMAX")
  field(DOL2, "QUAD:UNDH:1880:BMAX")
  field(DOL3, "QUAD:UNDH:1880:BMAX")
  field(DOL4, "QUAD:UNDH:1880:BMIN")
  field(DOL5, "QUAD:UNDH:1880:BMIN")
  field(DOL6, "QUAD:UNDH:1880:BMIN")
  field(LNK1, "QUAD:UNDH:1880:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:1880:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:1880:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:1880:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:1880:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:1880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:1880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:1880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:1880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:1880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:1880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:1880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:1880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:1880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:1880:EDES NPP MS")
  field(INPB, "QUAD:UNDH:1880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:1980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:1980:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:1980:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:1980:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:1980:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:1980:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:1980:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:1980:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:1980:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:1980:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:1980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:1980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:1980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:1980:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:1980:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:1980:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:1980:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:1980:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:1980:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:1980:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:1980:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:1980:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:1980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:1980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:1980:BMAX")
  field(DOL2, "QUAD:UNDH:1980:BMAX")
  field(DOL3, "QUAD:UNDH:1980:BMAX")
  field(DOL4, "QUAD:UNDH:1980:BMIN")
  field(DOL5, "QUAD:UNDH:1980:BMIN")
  field(DOL6, "QUAD:UNDH:1980:BMIN")
  field(LNK1, "QUAD:UNDH:1980:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:1980:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:1980:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:1980:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:1980:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:1980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:1980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:1980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:1980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:1980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:1980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:1980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:1980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:1980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:1980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:1980:EDES NPP MS")
  field(INPB, "QUAD:UNDH:1980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:2080:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:2080:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:2080:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:2080:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:2080:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:2080:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:2080:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:2080:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:2080:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:2080:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:2080:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:2080:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:2080:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:2080:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:2080:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:2080:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:2080:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:2080:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:2080:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:2080:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:2080:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:2080:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:2080:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:2080:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:2080:BMAX")
  field(DOL2, "QUAD:UNDH:2080:BMAX")
  field(DOL3, "QUAD:UNDH:2080:BMAX")
  field(DOL4, "QUAD:UNDH:2080:BMIN")
  field(DOL5, "QUAD:UNDH:2080:BMIN")
  field(DOL6, "QUAD:UNDH:2080:BMIN")
  field(LNK1, "QUAD:UNDH:2080:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:2080:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:2080:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:2080:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:2080:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:2080:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2080:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2080:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:2080:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:2080:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:2080:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2080:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2080:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2080:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2080:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2080:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:2080:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:2080:EDES NPP MS")
  field(INPB, "QUAD:UNDH:2080:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:2180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:2180:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:2180:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:2180:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:2180:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:2180:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:2180:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:2180:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:2180:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:2180:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:2180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:2180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:2180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:2180:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:2180:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:2180:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:2180:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:2180:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:2180:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:2180:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:2180:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:2180:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:2180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:2180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:2180:BMAX")
  field(DOL2, "QUAD:UNDH:2180:BMAX")
  field(DOL3, "QUAD:UNDH:2180:BMAX")
  field(DOL4, "QUAD:UNDH:2180:BMIN")
  field(DOL5, "QUAD:UNDH:2180:BMIN")
  field(DOL6, "QUAD:UNDH:2180:BMIN")
  field(LNK1, "QUAD:UNDH:2180:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:2180:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:2180:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:2180:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:2180:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:2180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:2180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:2180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:2180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:2180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:2180:EDES NPP MS")
  field(INPB, "QUAD:UNDH:2180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:2280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:2280:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:2280:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:2280:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:2280:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:2280:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:2280:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:2280:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:2280:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:2280:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:2280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:2280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:2280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:2280:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:2280:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:2280:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:2280:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:2280:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:2280:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:2280:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:2280:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:2280:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:2280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:2280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:2280:BMAX")
  field(DOL2, "QUAD:UNDH:2280:BMAX")
  field(DOL3, "QUAD:UNDH:2280:BMAX")
  field(DOL4, "QUAD:UNDH:2280:BMIN")
  field(DOL5, "QUAD:UNDH:2280:BMIN")
  field(DOL6, "QUAD:UNDH:2280:BMIN")
  field(LNK1, "QUAD:UNDH:2280:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:2280:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:2280:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:2280:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:2280:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:2280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:2280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:2280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:2280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:2280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:2280:EDES NPP MS")
  field(INPB, "QUAD:UNDH:2280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:2380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:2380:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:2380:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:2380:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:2380:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:2380:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:2380:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:2380:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:2380:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:2380:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:2380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:2380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:2380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:2380:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:2380:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:2380:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:2380:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:2380:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:2380:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:2380:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:2380:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:2380:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:2380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:2380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:2380:BMAX")
  field(DOL2, "QUAD:UNDH:2380:BMAX")
  field(DOL3, "QUAD:UNDH:2380:BMAX")
  field(DOL4, "QUAD:UNDH:2380:BMIN")
  field(DOL5, "QUAD:UNDH:2380:BMIN")
  field(DOL6, "QUAD:UNDH:2380:BMIN")
  field(LNK1, "QUAD:UNDH:2380:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:2380:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:2380:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:2380:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:2380:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:2380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:2380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:2380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:2380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:2380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:2380:EDES NPP MS")
  field(INPB, "QUAD:UNDH:2380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:2480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:2480:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:2480:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:2480:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:2480:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:2480:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:2480:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:2480:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:2480:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:2480:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:2480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:2480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:2480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:2480:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:2480:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:2480:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:2480:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:2480:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:2480:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:2480:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:2480:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:2480:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:2480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:2480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:2480:BMAX")
  field(DOL2, "QUAD:UNDH:2480:BMAX")
  field(DOL3, "QUAD:UNDH:2480:BMAX")
  field(DOL4, "QUAD:UNDH:2480:BMIN")
  field(DOL5, "QUAD:UNDH:2480:BMIN")
  field(DOL6, "QUAD:UNDH:2480:BMIN")
  field(LNK1, "QUAD:UNDH:2480:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:2480:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:2480:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:2480:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:2480:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:2480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:2480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:2480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:2480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:2480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:2480:EDES NPP MS")
  field(INPB, "QUAD:UNDH:2480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:2580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:2580:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:2580:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:2580:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:2580:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:2580:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:2580:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:2580:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:2580:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:2580:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:2580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:2580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:2580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:2580:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:2580:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:2580:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:2580:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:2580:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:2580:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:2580:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:2580:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:2580:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:2580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:2580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:2580:BMAX")
  field(DOL2, "QUAD:UNDH:2580:BMAX")
  field(DOL3, "QUAD:UNDH:2580:BMAX")
  field(DOL4, "QUAD:UNDH:2580:BMIN")
  field(DOL5, "QUAD:UNDH:2580:BMIN")
  field(DOL6, "QUAD:UNDH:2580:BMIN")
  field(LNK1, "QUAD:UNDH:2580:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:2580:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:2580:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:2580:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:2580:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:2580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:2580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:2580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:2580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:2580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:2580:EDES NPP MS")
  field(INPB, "QUAD:UNDH:2580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:2680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:2680:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:2680:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:2680:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:2680:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:2680:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:2680:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:2680:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:2680:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:2680:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:2680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:2680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:2680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:2680:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:2680:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:2680:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:2680:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:2680:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:2680:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:2680:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:2680:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:2680:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:2680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:2680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:2680:BMAX")
  field(DOL2, "QUAD:UNDH:2680:BMAX")
  field(DOL3, "QUAD:UNDH:2680:BMAX")
  field(DOL4, "QUAD:UNDH:2680:BMIN")
  field(DOL5, "QUAD:UNDH:2680:BMIN")
  field(DOL6, "QUAD:UNDH:2680:BMIN")
  field(LNK1, "QUAD:UNDH:2680:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:2680:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:2680:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:2680:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:2680:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:2680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:2680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:2680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:2680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:2680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:2680:EDES NPP MS")
  field(INPB, "QUAD:UNDH:2680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:2780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:2780:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:2780:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:2780:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:2780:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:2780:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:2780:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:2780:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:2780:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:2780:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:2780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:2780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:2780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:2780:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:2780:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:2780:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:2780:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:2780:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:2780:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:2780:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:2780:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:2780:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:2780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:2780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:2780:BMAX")
  field(DOL2, "QUAD:UNDH:2780:BMAX")
  field(DOL3, "QUAD:UNDH:2780:BMAX")
  field(DOL4, "QUAD:UNDH:2780:BMIN")
  field(DOL5, "QUAD:UNDH:2780:BMIN")
  field(DOL6, "QUAD:UNDH:2780:BMIN")
  field(LNK1, "QUAD:UNDH:2780:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:2780:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:2780:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:2780:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:2780:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:2780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:2780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:2780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:2780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:2780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:2780:EDES NPP MS")
  field(INPB, "QUAD:UNDH:2780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:2880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:2880:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:2880:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:2880:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:2880:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:2880:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:2880:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:2880:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:2880:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:2880:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:2880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:2880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:2880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:2880:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:2880:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:2880:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:2880:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:2880:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:2880:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:2880:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:2880:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:2880:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:2880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:2880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:2880:BMAX")
  field(DOL2, "QUAD:UNDH:2880:BMAX")
  field(DOL3, "QUAD:UNDH:2880:BMAX")
  field(DOL4, "QUAD:UNDH:2880:BMIN")
  field(DOL5, "QUAD:UNDH:2880:BMIN")
  field(DOL6, "QUAD:UNDH:2880:BMIN")
  field(LNK1, "QUAD:UNDH:2880:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:2880:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:2880:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:2880:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:2880:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:2880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:2880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:2880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:2880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:2880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:2880:EDES NPP MS")
  field(INPB, "QUAD:UNDH:2880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:2980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:2980:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:2980:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:2980:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:2980:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:2980:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:2980:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:2980:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:2980:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:2980:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:2980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:2980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:2980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:2980:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:2980:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:2980:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:2980:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:2980:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:2980:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:2980:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:2980:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:2980:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:2980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:2980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:2980:BMAX")
  field(DOL2, "QUAD:UNDH:2980:BMAX")
  field(DOL3, "QUAD:UNDH:2980:BMAX")
  field(DOL4, "QUAD:UNDH:2980:BMIN")
  field(DOL5, "QUAD:UNDH:2980:BMIN")
  field(DOL6, "QUAD:UNDH:2980:BMIN")
  field(LNK1, "QUAD:UNDH:2980:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:2980:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:2980:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:2980:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:2980:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:2980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:2980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:2980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:2980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:2980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:2980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:2980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:2980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:2980:EDES NPP MS")
  field(INPB, "QUAD:UNDH:2980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:3080:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:3080:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:3080:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:3080:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:3080:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:3080:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:3080:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:3080:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:3080:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:3080:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:3080:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:3080:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:3080:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:3080:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:3080:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:3080:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:3080:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:3080:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:3080:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:3080:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:3080:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:3080:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:3080:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:3080:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:3080:BMAX")
  field(DOL2, "QUAD:UNDH:3080:BMAX")
  field(DOL3, "QUAD:UNDH:3080:BMAX")
  field(DOL4, "QUAD:UNDH:3080:BMIN")
  field(DOL5, "QUAD:UNDH:3080:BMIN")
  field(DOL6, "QUAD:UNDH:3080:BMIN")
  field(LNK1, "QUAD:UNDH:3080:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:3080:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:3080:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:3080:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:3080:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:3080:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3080:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3080:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:3080:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:3080:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:3080:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3080:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3080:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3080:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3080:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3080:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:3080:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:3080:EDES NPP MS")
  field(INPB, "QUAD:UNDH:3080:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:3180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:3180:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:3180:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:3180:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:3180:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:3180:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:3180:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:3180:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:3180:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:3180:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:3180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:3180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:3180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:3180:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:3180:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:3180:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:3180:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:3180:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:3180:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:3180:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:3180:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:3180:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:3180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:3180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:3180:BMAX")
  field(DOL2, "QUAD:UNDH:3180:BMAX")
  field(DOL3, "QUAD:UNDH:3180:BMAX")
  field(DOL4, "QUAD:UNDH:3180:BMIN")
  field(DOL5, "QUAD:UNDH:3180:BMIN")
  field(DOL6, "QUAD:UNDH:3180:BMIN")
  field(LNK1, "QUAD:UNDH:3180:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:3180:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:3180:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:3180:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:3180:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:3180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:3180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:3180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:3180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:3180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:3180:EDES NPP MS")
  field(INPB, "QUAD:UNDH:3180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:3280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:3280:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:3280:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:3280:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:3280:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:3280:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:3280:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:3280:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:3280:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:3280:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:3280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:3280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:3280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:3280:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:3280:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:3280:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:3280:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:3280:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:3280:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:3280:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:3280:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:3280:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:3280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:3280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:3280:BMAX")
  field(DOL2, "QUAD:UNDH:3280:BMAX")
  field(DOL3, "QUAD:UNDH:3280:BMAX")
  field(DOL4, "QUAD:UNDH:3280:BMIN")
  field(DOL5, "QUAD:UNDH:3280:BMIN")
  field(DOL6, "QUAD:UNDH:3280:BMIN")
  field(LNK1, "QUAD:UNDH:3280:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:3280:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:3280:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:3280:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:3280:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:3280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:3280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:3280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:3280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:3280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:3280:EDES NPP MS")
  field(INPB, "QUAD:UNDH:3280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:3380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:3380:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:3380:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:3380:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:3380:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:3380:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:3380:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:3380:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:3380:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:3380:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:3380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:3380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:3380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:3380:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:3380:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:3380:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:3380:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:3380:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:3380:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:3380:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:3380:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:3380:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:3380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:3380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:3380:BMAX")
  field(DOL2, "QUAD:UNDH:3380:BMAX")
  field(DOL3, "QUAD:UNDH:3380:BMAX")
  field(DOL4, "QUAD:UNDH:3380:BMIN")
  field(DOL5, "QUAD:UNDH:3380:BMIN")
  field(DOL6, "QUAD:UNDH:3380:BMIN")
  field(LNK1, "QUAD:UNDH:3380:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:3380:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:3380:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:3380:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:3380:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:3380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:3380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:3380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:3380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:3380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:3380:EDES NPP MS")
  field(INPB, "QUAD:UNDH:3380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:3480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:3480:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:3480:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:3480:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:3480:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:3480:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:3480:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:3480:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:3480:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:3480:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:3480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:3480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:3480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:3480:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:3480:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:3480:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:3480:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:3480:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:3480:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:3480:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:3480:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:3480:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:3480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:3480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:3480:BMAX")
  field(DOL2, "QUAD:UNDH:3480:BMAX")
  field(DOL3, "QUAD:UNDH:3480:BMAX")
  field(DOL4, "QUAD:UNDH:3480:BMIN")
  field(DOL5, "QUAD:UNDH:3480:BMIN")
  field(DOL6, "QUAD:UNDH:3480:BMIN")
  field(LNK1, "QUAD:UNDH:3480:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:3480:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:3480:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:3480:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:3480:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:3480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:3480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:3480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:3480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:3480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:3480:EDES NPP MS")
  field(INPB, "QUAD:UNDH:3480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:3580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:3580:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:3580:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:3580:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:3580:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:3580:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:3580:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:3580:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:3580:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:3580:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:3580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:3580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:3580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:3580:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:3580:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:3580:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:3580:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:3580:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:3580:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:3580:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:3580:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:3580:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:3580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:3580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:3580:BMAX")
  field(DOL2, "QUAD:UNDH:3580:BMAX")
  field(DOL3, "QUAD:UNDH:3580:BMAX")
  field(DOL4, "QUAD:UNDH:3580:BMIN")
  field(DOL5, "QUAD:UNDH:3580:BMIN")
  field(DOL6, "QUAD:UNDH:3580:BMIN")
  field(LNK1, "QUAD:UNDH:3580:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:3580:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:3580:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:3580:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:3580:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:3580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:3580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:3580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:3580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:3580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:3580:EDES NPP MS")
  field(INPB, "QUAD:UNDH:3580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:3680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:3680:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:3680:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:3680:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:3680:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:3680:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:3680:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:3680:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:3680:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:3680:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:3680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:3680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:3680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:3680:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:3680:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:3680:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:3680:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:3680:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:3680:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:3680:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:3680:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:3680:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:3680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:3680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:3680:BMAX")
  field(DOL2, "QUAD:UNDH:3680:BMAX")
  field(DOL3, "QUAD:UNDH:3680:BMAX")
  field(DOL4, "QUAD:UNDH:3680:BMIN")
  field(DOL5, "QUAD:UNDH:3680:BMIN")
  field(DOL6, "QUAD:UNDH:3680:BMIN")
  field(LNK1, "QUAD:UNDH:3680:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:3680:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:3680:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:3680:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:3680:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:3680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:3680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:3680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:3680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:3680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:3680:EDES NPP MS")
  field(INPB, "QUAD:UNDH:3680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:3780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:3780:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:3780:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:3780:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:3780:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:3780:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:3780:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:3780:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:3780:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:3780:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:3780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:3780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:3780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:3780:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:3780:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:3780:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:3780:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:3780:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:3780:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:3780:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:3780:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:3780:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:3780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:3780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:3780:BMAX")
  field(DOL2, "QUAD:UNDH:3780:BMAX")
  field(DOL3, "QUAD:UNDH:3780:BMAX")
  field(DOL4, "QUAD:UNDH:3780:BMIN")
  field(DOL5, "QUAD:UNDH:3780:BMIN")
  field(DOL6, "QUAD:UNDH:3780:BMIN")
  field(LNK1, "QUAD:UNDH:3780:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:3780:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:3780:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:3780:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:3780:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:3780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:3780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:3780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:3780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:3780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:3780:EDES NPP MS")
  field(INPB, "QUAD:UNDH:3780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:3880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:3880:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:3880:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:3880:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:3880:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:3880:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:3880:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:3880:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:3880:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:3880:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:3880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:3880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:3880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:3880:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:3880:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:3880:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:3880:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:3880:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:3880:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:3880:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:3880:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:3880:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:3880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:3880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:3880:BMAX")
  field(DOL2, "QUAD:UNDH:3880:BMAX")
  field(DOL3, "QUAD:UNDH:3880:BMAX")
  field(DOL4, "QUAD:UNDH:3880:BMIN")
  field(DOL5, "QUAD:UNDH:3880:BMIN")
  field(DOL6, "QUAD:UNDH:3880:BMIN")
  field(LNK1, "QUAD:UNDH:3880:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:3880:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:3880:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:3880:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:3880:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:3880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:3880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:3880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:3880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:3880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:3880:EDES NPP MS")
  field(INPB, "QUAD:UNDH:3880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:3980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:3980:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:3980:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:3980:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:3980:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:3980:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:3980:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:3980:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:3980:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:3980:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:3980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:3980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:3980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:3980:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:3980:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:3980:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:3980:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:3980:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:3980:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:3980:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:3980:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:3980:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:3980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:3980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:3980:BMAX")
  field(DOL2, "QUAD:UNDH:3980:BMAX")
  field(DOL3, "QUAD:UNDH:3980:BMAX")
  field(DOL4, "QUAD:UNDH:3980:BMIN")
  field(DOL5, "QUAD:UNDH:3980:BMIN")
  field(DOL6, "QUAD:UNDH:3980:BMIN")
  field(LNK1, "QUAD:UNDH:3980:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:3980:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:3980:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:3980:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:3980:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:3980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:3980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:3980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:3980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:3980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:3980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:3980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:3980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:3980:EDES NPP MS")
  field(INPB, "QUAD:UNDH:3980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:4080:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:4080:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:4080:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:4080:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:4080:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:4080:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:4080:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:4080:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:4080:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:4080:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:4080:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:4080:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:4080:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:4080:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:4080:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:4080:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:4080:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:4080:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:4080:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:4080:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:4080:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:4080:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:4080:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:4080:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:4080:BMAX")
  field(DOL2, "QUAD:UNDH:4080:BMAX")
  field(DOL3, "QUAD:UNDH:4080:BMAX")
  field(DOL4, "QUAD:UNDH:4080:BMIN")
  field(DOL5, "QUAD:UNDH:4080:BMIN")
  field(DOL6, "QUAD:UNDH:4080:BMIN")
  field(LNK1, "QUAD:UNDH:4080:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:4080:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:4080:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:4080:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:4080:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:4080:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4080:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4080:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:4080:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:4080:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:4080:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4080:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4080:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4080:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4080:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4080:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:4080:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:4080:EDES NPP MS")
  field(INPB, "QUAD:UNDH:4080:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:4180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:4180:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:4180:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:4180:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:4180:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:4180:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:4180:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:4180:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:4180:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:4180:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:4180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:4180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:4180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:4180:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:4180:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:4180:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:4180:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:4180:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:4180:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:4180:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:4180:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:4180:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:4180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:4180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:4180:BMAX")
  field(DOL2, "QUAD:UNDH:4180:BMAX")
  field(DOL3, "QUAD:UNDH:4180:BMAX")
  field(DOL4, "QUAD:UNDH:4180:BMIN")
  field(DOL5, "QUAD:UNDH:4180:BMIN")
  field(DOL6, "QUAD:UNDH:4180:BMIN")
  field(LNK1, "QUAD:UNDH:4180:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:4180:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:4180:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:4180:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:4180:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:4180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:4180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:4180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:4180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:4180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:4180:EDES NPP MS")
  field(INPB, "QUAD:UNDH:4180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:4280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:4280:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:4280:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:4280:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:4280:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:4280:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:4280:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:4280:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:4280:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:4280:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:4280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:4280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:4280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:4280:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:4280:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:4280:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:4280:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:4280:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:4280:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:4280:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:4280:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:4280:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:4280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:4280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:4280:BMAX")
  field(DOL2, "QUAD:UNDH:4280:BMAX")
  field(DOL3, "QUAD:UNDH:4280:BMAX")
  field(DOL4, "QUAD:UNDH:4280:BMIN")
  field(DOL5, "QUAD:UNDH:4280:BMIN")
  field(DOL6, "QUAD:UNDH:4280:BMIN")
  field(LNK1, "QUAD:UNDH:4280:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:4280:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:4280:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:4280:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:4280:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:4280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:4280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:4280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:4280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:4280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:4280:EDES NPP MS")
  field(INPB, "QUAD:UNDH:4280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:4380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:4380:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:4380:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:4380:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:4380:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:4380:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:4380:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:4380:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:4380:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:4380:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:4380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:4380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:4380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:4380:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:4380:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:4380:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:4380:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:4380:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:4380:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:4380:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:4380:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:4380:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:4380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:4380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:4380:BMAX")
  field(DOL2, "QUAD:UNDH:4380:BMAX")
  field(DOL3, "QUAD:UNDH:4380:BMAX")
  field(DOL4, "QUAD:UNDH:4380:BMIN")
  field(DOL5, "QUAD:UNDH:4380:BMIN")
  field(DOL6, "QUAD:UNDH:4380:BMIN")
  field(LNK1, "QUAD:UNDH:4380:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:4380:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:4380:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:4380:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:4380:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:4380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:4380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:4380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:4380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:4380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:4380:EDES NPP MS")
  field(INPB, "QUAD:UNDH:4380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:4480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:4480:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:4480:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:4480:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:4480:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:4480:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:4480:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:4480:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:4480:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:4480:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:4480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:4480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:4480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:4480:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:4480:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:4480:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:4480:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:4480:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:4480:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:4480:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:4480:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:4480:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:4480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:4480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:4480:BMAX")
  field(DOL2, "QUAD:UNDH:4480:BMAX")
  field(DOL3, "QUAD:UNDH:4480:BMAX")
  field(DOL4, "QUAD:UNDH:4480:BMIN")
  field(DOL5, "QUAD:UNDH:4480:BMIN")
  field(DOL6, "QUAD:UNDH:4480:BMIN")
  field(LNK1, "QUAD:UNDH:4480:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:4480:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:4480:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:4480:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:4480:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:4480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:4480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:4480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:4480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:4480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:4480:EDES NPP MS")
  field(INPB, "QUAD:UNDH:4480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:4580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:4580:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:4580:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:4580:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:4580:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:4580:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:4580:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:4580:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:4580:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:4580:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:4580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:4580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:4580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:4580:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:4580:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:4580:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:4580:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:4580:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:4580:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:4580:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:4580:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:4580:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:4580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:4580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:4580:BMAX")
  field(DOL2, "QUAD:UNDH:4580:BMAX")
  field(DOL3, "QUAD:UNDH:4580:BMAX")
  field(DOL4, "QUAD:UNDH:4580:BMIN")
  field(DOL5, "QUAD:UNDH:4580:BMIN")
  field(DOL6, "QUAD:UNDH:4580:BMIN")
  field(LNK1, "QUAD:UNDH:4580:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:4580:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:4580:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:4580:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:4580:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:4580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:4580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:4580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:4580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:4580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:4580:EDES NPP MS")
  field(INPB, "QUAD:UNDH:4580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:4680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:4680:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:4680:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:4680:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:4680:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:4680:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:4680:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:4680:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:4680:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:4680:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:4680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:4680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:4680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:4680:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:4680:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:4680:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:4680:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:4680:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:4680:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:4680:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:4680:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:4680:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:4680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:4680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:4680:BMAX")
  field(DOL2, "QUAD:UNDH:4680:BMAX")
  field(DOL3, "QUAD:UNDH:4680:BMAX")
  field(DOL4, "QUAD:UNDH:4680:BMIN")
  field(DOL5, "QUAD:UNDH:4680:BMIN")
  field(DOL6, "QUAD:UNDH:4680:BMIN")
  field(LNK1, "QUAD:UNDH:4680:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:4680:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:4680:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:4680:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:4680:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:4680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:4680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:4680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:4680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:4680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:4680:EDES NPP MS")
  field(INPB, "QUAD:UNDH:4680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDH:4780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDH:4780:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDH:4780:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDH:4780:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDH:4780:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDH:4780:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDH:4780:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDH:4780:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDH:4780:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDH:4780:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDH:4780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDH:4780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDH:4780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDH:4780:EDES.PROC PP")
    field(LNK2, "QUAD:UNDH:4780:EACT.PROC PP")
    field(LNK3, "QUAD:UNDH:4780:EERR.DISA PP")
    field(LNK4, "QUAD:UNDH:4780:ECON.PROC PP")
    field(LNK5, "QUAD:UNDH:4780:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDH:4780:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDH:4780:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDH:4780:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDH:4780:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDH:4780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDH:4780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDH:4780:BMAX")
  field(DOL2, "QUAD:UNDH:4780:BMAX")
  field(DOL3, "QUAD:UNDH:4780:BMAX")
  field(DOL4, "QUAD:UNDH:4780:BMIN")
  field(DOL5, "QUAD:UNDH:4780:BMIN")
  field(DOL6, "QUAD:UNDH:4780:BMIN")
  field(LNK1, "QUAD:UNDH:4780:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDH:4780:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDH:4780:BLEM.HOPR")
  field(LNK4, "QUAD:UNDH:4780:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDH:4780:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDH:4780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDH:4780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDH:4780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDH:4780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDH:4780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDH:4780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDH:4780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDH:4780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDH:4780:EDES NPP MS")
  field(INPB, "QUAD:UNDH:4780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:1380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:1380:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:1380:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:1380:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:1380:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:1380:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:1380:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:1380:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:1380:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:1380:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:1380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:1380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:1380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:1380:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:1380:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:1380:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:1380:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:1380:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:1380:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:1380:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:1380:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:1380:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:1380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:1380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:1380:BMAX")
  field(DOL2, "XCOR:UNDH:1380:BMAX")
  field(DOL3, "XCOR:UNDH:1380:BMAX")
  field(DOL4, "XCOR:UNDH:1380:BMIN")
  field(DOL5, "XCOR:UNDH:1380:BMIN")
  field(DOL6, "XCOR:UNDH:1380:BMIN")
  field(LNK1, "XCOR:UNDH:1380:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:1380:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:1380:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:1380:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:1380:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:1380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:1380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:1380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:1380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:1380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:1380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:1380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:1380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:1380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:1380:EDES NPP MS")
  field(INPB, "XCOR:UNDH:1380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:1480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:1480:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:1480:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:1480:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:1480:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:1480:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:1480:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:1480:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:1480:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:1480:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:1480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:1480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:1480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:1480:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:1480:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:1480:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:1480:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:1480:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:1480:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:1480:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:1480:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:1480:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:1480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:1480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:1480:BMAX")
  field(DOL2, "XCOR:UNDH:1480:BMAX")
  field(DOL3, "XCOR:UNDH:1480:BMAX")
  field(DOL4, "XCOR:UNDH:1480:BMIN")
  field(DOL5, "XCOR:UNDH:1480:BMIN")
  field(DOL6, "XCOR:UNDH:1480:BMIN")
  field(LNK1, "XCOR:UNDH:1480:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:1480:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:1480:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:1480:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:1480:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:1480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:1480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:1480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:1480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:1480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:1480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:1480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:1480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:1480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:1480:EDES NPP MS")
  field(INPB, "XCOR:UNDH:1480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:1580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:1580:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:1580:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:1580:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:1580:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:1580:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:1580:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:1580:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:1580:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:1580:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:1580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:1580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:1580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:1580:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:1580:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:1580:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:1580:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:1580:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:1580:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:1580:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:1580:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:1580:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:1580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:1580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:1580:BMAX")
  field(DOL2, "XCOR:UNDH:1580:BMAX")
  field(DOL3, "XCOR:UNDH:1580:BMAX")
  field(DOL4, "XCOR:UNDH:1580:BMIN")
  field(DOL5, "XCOR:UNDH:1580:BMIN")
  field(DOL6, "XCOR:UNDH:1580:BMIN")
  field(LNK1, "XCOR:UNDH:1580:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:1580:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:1580:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:1580:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:1580:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:1580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:1580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:1580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:1580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:1580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:1580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:1580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:1580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:1580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:1580:EDES NPP MS")
  field(INPB, "XCOR:UNDH:1580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:1680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:1680:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:1680:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:1680:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:1680:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:1680:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:1680:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:1680:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:1680:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:1680:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:1680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:1680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:1680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:1680:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:1680:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:1680:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:1680:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:1680:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:1680:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:1680:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:1680:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:1680:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:1680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:1680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:1680:BMAX")
  field(DOL2, "XCOR:UNDH:1680:BMAX")
  field(DOL3, "XCOR:UNDH:1680:BMAX")
  field(DOL4, "XCOR:UNDH:1680:BMIN")
  field(DOL5, "XCOR:UNDH:1680:BMIN")
  field(DOL6, "XCOR:UNDH:1680:BMIN")
  field(LNK1, "XCOR:UNDH:1680:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:1680:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:1680:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:1680:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:1680:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:1680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:1680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:1680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:1680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:1680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:1680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:1680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:1680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:1680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:1680:EDES NPP MS")
  field(INPB, "XCOR:UNDH:1680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:1780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:1780:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:1780:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:1780:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:1780:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:1780:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:1780:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:1780:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:1780:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:1780:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:1780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:1780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:1780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:1780:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:1780:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:1780:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:1780:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:1780:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:1780:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:1780:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:1780:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:1780:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:1780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:1780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:1780:BMAX")
  field(DOL2, "XCOR:UNDH:1780:BMAX")
  field(DOL3, "XCOR:UNDH:1780:BMAX")
  field(DOL4, "XCOR:UNDH:1780:BMIN")
  field(DOL5, "XCOR:UNDH:1780:BMIN")
  field(DOL6, "XCOR:UNDH:1780:BMIN")
  field(LNK1, "XCOR:UNDH:1780:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:1780:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:1780:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:1780:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:1780:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:1780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:1780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:1780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:1780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:1780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:1780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:1780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:1780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:1780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:1780:EDES NPP MS")
  field(INPB, "XCOR:UNDH:1780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:1880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:1880:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:1880:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:1880:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:1880:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:1880:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:1880:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:1880:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:1880:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:1880:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:1880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:1880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:1880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:1880:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:1880:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:1880:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:1880:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:1880:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:1880:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:1880:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:1880:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:1880:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:1880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:1880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:1880:BMAX")
  field(DOL2, "XCOR:UNDH:1880:BMAX")
  field(DOL3, "XCOR:UNDH:1880:BMAX")
  field(DOL4, "XCOR:UNDH:1880:BMIN")
  field(DOL5, "XCOR:UNDH:1880:BMIN")
  field(DOL6, "XCOR:UNDH:1880:BMIN")
  field(LNK1, "XCOR:UNDH:1880:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:1880:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:1880:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:1880:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:1880:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:1880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:1880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:1880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:1880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:1880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:1880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:1880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:1880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:1880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:1880:EDES NPP MS")
  field(INPB, "XCOR:UNDH:1880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:1980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:1980:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:1980:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:1980:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:1980:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:1980:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:1980:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:1980:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:1980:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:1980:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:1980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:1980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:1980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:1980:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:1980:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:1980:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:1980:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:1980:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:1980:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:1980:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:1980:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:1980:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:1980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:1980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:1980:BMAX")
  field(DOL2, "XCOR:UNDH:1980:BMAX")
  field(DOL3, "XCOR:UNDH:1980:BMAX")
  field(DOL4, "XCOR:UNDH:1980:BMIN")
  field(DOL5, "XCOR:UNDH:1980:BMIN")
  field(DOL6, "XCOR:UNDH:1980:BMIN")
  field(LNK1, "XCOR:UNDH:1980:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:1980:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:1980:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:1980:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:1980:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:1980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:1980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:1980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:1980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:1980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:1980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:1980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:1980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:1980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:1980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:1980:EDES NPP MS")
  field(INPB, "XCOR:UNDH:1980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:2080:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:2080:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:2080:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:2080:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:2080:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:2080:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:2080:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:2080:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:2080:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:2080:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:2080:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:2080:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:2080:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:2080:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:2080:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:2080:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:2080:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:2080:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:2080:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:2080:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:2080:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:2080:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:2080:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:2080:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:2080:BMAX")
  field(DOL2, "XCOR:UNDH:2080:BMAX")
  field(DOL3, "XCOR:UNDH:2080:BMAX")
  field(DOL4, "XCOR:UNDH:2080:BMIN")
  field(DOL5, "XCOR:UNDH:2080:BMIN")
  field(DOL6, "XCOR:UNDH:2080:BMIN")
  field(LNK1, "XCOR:UNDH:2080:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:2080:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:2080:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:2080:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:2080:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:2080:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2080:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2080:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:2080:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:2080:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:2080:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2080:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2080:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2080:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2080:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2080:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:2080:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:2080:EDES NPP MS")
  field(INPB, "XCOR:UNDH:2080:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:2180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:2180:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:2180:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:2180:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:2180:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:2180:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:2180:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:2180:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:2180:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:2180:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:2180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:2180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:2180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:2180:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:2180:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:2180:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:2180:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:2180:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:2180:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:2180:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:2180:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:2180:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:2180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:2180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:2180:BMAX")
  field(DOL2, "XCOR:UNDH:2180:BMAX")
  field(DOL3, "XCOR:UNDH:2180:BMAX")
  field(DOL4, "XCOR:UNDH:2180:BMIN")
  field(DOL5, "XCOR:UNDH:2180:BMIN")
  field(DOL6, "XCOR:UNDH:2180:BMIN")
  field(LNK1, "XCOR:UNDH:2180:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:2180:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:2180:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:2180:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:2180:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:2180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:2180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:2180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:2180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:2180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:2180:EDES NPP MS")
  field(INPB, "XCOR:UNDH:2180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:2280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:2280:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:2280:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:2280:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:2280:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:2280:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:2280:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:2280:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:2280:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:2280:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:2280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:2280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:2280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:2280:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:2280:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:2280:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:2280:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:2280:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:2280:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:2280:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:2280:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:2280:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:2280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:2280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:2280:BMAX")
  field(DOL2, "XCOR:UNDH:2280:BMAX")
  field(DOL3, "XCOR:UNDH:2280:BMAX")
  field(DOL4, "XCOR:UNDH:2280:BMIN")
  field(DOL5, "XCOR:UNDH:2280:BMIN")
  field(DOL6, "XCOR:UNDH:2280:BMIN")
  field(LNK1, "XCOR:UNDH:2280:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:2280:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:2280:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:2280:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:2280:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:2280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:2280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:2280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:2280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:2280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:2280:EDES NPP MS")
  field(INPB, "XCOR:UNDH:2280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:2380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:2380:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:2380:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:2380:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:2380:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:2380:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:2380:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:2380:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:2380:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:2380:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:2380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:2380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:2380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:2380:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:2380:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:2380:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:2380:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:2380:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:2380:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:2380:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:2380:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:2380:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:2380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:2380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:2380:BMAX")
  field(DOL2, "XCOR:UNDH:2380:BMAX")
  field(DOL3, "XCOR:UNDH:2380:BMAX")
  field(DOL4, "XCOR:UNDH:2380:BMIN")
  field(DOL5, "XCOR:UNDH:2380:BMIN")
  field(DOL6, "XCOR:UNDH:2380:BMIN")
  field(LNK1, "XCOR:UNDH:2380:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:2380:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:2380:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:2380:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:2380:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:2380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:2380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:2380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:2380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:2380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:2380:EDES NPP MS")
  field(INPB, "XCOR:UNDH:2380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:2480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:2480:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:2480:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:2480:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:2480:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:2480:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:2480:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:2480:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:2480:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:2480:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:2480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:2480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:2480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:2480:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:2480:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:2480:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:2480:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:2480:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:2480:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:2480:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:2480:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:2480:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:2480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:2480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:2480:BMAX")
  field(DOL2, "XCOR:UNDH:2480:BMAX")
  field(DOL3, "XCOR:UNDH:2480:BMAX")
  field(DOL4, "XCOR:UNDH:2480:BMIN")
  field(DOL5, "XCOR:UNDH:2480:BMIN")
  field(DOL6, "XCOR:UNDH:2480:BMIN")
  field(LNK1, "XCOR:UNDH:2480:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:2480:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:2480:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:2480:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:2480:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:2480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:2480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:2480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:2480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:2480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:2480:EDES NPP MS")
  field(INPB, "XCOR:UNDH:2480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:2580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:2580:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:2580:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:2580:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:2580:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:2580:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:2580:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:2580:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:2580:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:2580:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:2580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:2580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:2580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:2580:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:2580:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:2580:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:2580:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:2580:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:2580:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:2580:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:2580:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:2580:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:2580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:2580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:2580:BMAX")
  field(DOL2, "XCOR:UNDH:2580:BMAX")
  field(DOL3, "XCOR:UNDH:2580:BMAX")
  field(DOL4, "XCOR:UNDH:2580:BMIN")
  field(DOL5, "XCOR:UNDH:2580:BMIN")
  field(DOL6, "XCOR:UNDH:2580:BMIN")
  field(LNK1, "XCOR:UNDH:2580:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:2580:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:2580:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:2580:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:2580:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:2580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:2580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:2580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:2580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:2580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:2580:EDES NPP MS")
  field(INPB, "XCOR:UNDH:2580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:2680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:2680:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:2680:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:2680:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:2680:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:2680:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:2680:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:2680:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:2680:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:2680:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:2680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:2680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:2680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:2680:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:2680:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:2680:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:2680:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:2680:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:2680:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:2680:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:2680:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:2680:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:2680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:2680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:2680:BMAX")
  field(DOL2, "XCOR:UNDH:2680:BMAX")
  field(DOL3, "XCOR:UNDH:2680:BMAX")
  field(DOL4, "XCOR:UNDH:2680:BMIN")
  field(DOL5, "XCOR:UNDH:2680:BMIN")
  field(DOL6, "XCOR:UNDH:2680:BMIN")
  field(LNK1, "XCOR:UNDH:2680:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:2680:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:2680:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:2680:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:2680:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:2680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:2680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:2680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:2680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:2680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:2680:EDES NPP MS")
  field(INPB, "XCOR:UNDH:2680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:2780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:2780:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:2780:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:2780:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:2780:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:2780:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:2780:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:2780:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:2780:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:2780:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:2780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:2780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:2780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:2780:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:2780:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:2780:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:2780:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:2780:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:2780:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:2780:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:2780:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:2780:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:2780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:2780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:2780:BMAX")
  field(DOL2, "XCOR:UNDH:2780:BMAX")
  field(DOL3, "XCOR:UNDH:2780:BMAX")
  field(DOL4, "XCOR:UNDH:2780:BMIN")
  field(DOL5, "XCOR:UNDH:2780:BMIN")
  field(DOL6, "XCOR:UNDH:2780:BMIN")
  field(LNK1, "XCOR:UNDH:2780:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:2780:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:2780:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:2780:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:2780:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:2780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:2780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:2780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:2780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:2780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:2780:EDES NPP MS")
  field(INPB, "XCOR:UNDH:2780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:2880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:2880:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:2880:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:2880:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:2880:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:2880:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:2880:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:2880:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:2880:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:2880:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:2880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:2880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:2880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:2880:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:2880:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:2880:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:2880:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:2880:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:2880:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:2880:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:2880:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:2880:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:2880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:2880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:2880:BMAX")
  field(DOL2, "XCOR:UNDH:2880:BMAX")
  field(DOL3, "XCOR:UNDH:2880:BMAX")
  field(DOL4, "XCOR:UNDH:2880:BMIN")
  field(DOL5, "XCOR:UNDH:2880:BMIN")
  field(DOL6, "XCOR:UNDH:2880:BMIN")
  field(LNK1, "XCOR:UNDH:2880:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:2880:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:2880:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:2880:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:2880:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:2880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:2880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:2880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:2880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:2880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:2880:EDES NPP MS")
  field(INPB, "XCOR:UNDH:2880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:2980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:2980:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:2980:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:2980:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:2980:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:2980:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:2980:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:2980:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:2980:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:2980:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:2980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:2980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:2980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:2980:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:2980:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:2980:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:2980:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:2980:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:2980:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:2980:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:2980:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:2980:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:2980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:2980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:2980:BMAX")
  field(DOL2, "XCOR:UNDH:2980:BMAX")
  field(DOL3, "XCOR:UNDH:2980:BMAX")
  field(DOL4, "XCOR:UNDH:2980:BMIN")
  field(DOL5, "XCOR:UNDH:2980:BMIN")
  field(DOL6, "XCOR:UNDH:2980:BMIN")
  field(LNK1, "XCOR:UNDH:2980:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:2980:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:2980:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:2980:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:2980:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:2980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:2980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:2980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:2980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:2980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:2980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:2980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:2980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:2980:EDES NPP MS")
  field(INPB, "XCOR:UNDH:2980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:3080:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:3080:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:3080:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:3080:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:3080:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:3080:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:3080:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:3080:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:3080:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:3080:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:3080:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:3080:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:3080:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:3080:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:3080:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:3080:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:3080:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:3080:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:3080:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:3080:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:3080:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:3080:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:3080:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:3080:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:3080:BMAX")
  field(DOL2, "XCOR:UNDH:3080:BMAX")
  field(DOL3, "XCOR:UNDH:3080:BMAX")
  field(DOL4, "XCOR:UNDH:3080:BMIN")
  field(DOL5, "XCOR:UNDH:3080:BMIN")
  field(DOL6, "XCOR:UNDH:3080:BMIN")
  field(LNK1, "XCOR:UNDH:3080:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:3080:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:3080:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:3080:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:3080:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:3080:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3080:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3080:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:3080:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:3080:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:3080:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3080:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3080:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3080:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3080:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3080:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:3080:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:3080:EDES NPP MS")
  field(INPB, "XCOR:UNDH:3080:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:3180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:3180:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:3180:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:3180:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:3180:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:3180:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:3180:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:3180:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:3180:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:3180:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:3180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:3180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:3180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:3180:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:3180:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:3180:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:3180:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:3180:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:3180:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:3180:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:3180:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:3180:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:3180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:3180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:3180:BMAX")
  field(DOL2, "XCOR:UNDH:3180:BMAX")
  field(DOL3, "XCOR:UNDH:3180:BMAX")
  field(DOL4, "XCOR:UNDH:3180:BMIN")
  field(DOL5, "XCOR:UNDH:3180:BMIN")
  field(DOL6, "XCOR:UNDH:3180:BMIN")
  field(LNK1, "XCOR:UNDH:3180:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:3180:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:3180:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:3180:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:3180:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:3180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:3180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:3180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:3180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:3180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:3180:EDES NPP MS")
  field(INPB, "XCOR:UNDH:3180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:3280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:3280:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:3280:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:3280:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:3280:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:3280:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:3280:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:3280:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:3280:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:3280:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:3280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:3280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:3280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:3280:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:3280:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:3280:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:3280:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:3280:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:3280:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:3280:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:3280:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:3280:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:3280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:3280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:3280:BMAX")
  field(DOL2, "XCOR:UNDH:3280:BMAX")
  field(DOL3, "XCOR:UNDH:3280:BMAX")
  field(DOL4, "XCOR:UNDH:3280:BMIN")
  field(DOL5, "XCOR:UNDH:3280:BMIN")
  field(DOL6, "XCOR:UNDH:3280:BMIN")
  field(LNK1, "XCOR:UNDH:3280:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:3280:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:3280:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:3280:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:3280:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:3280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:3280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:3280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:3280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:3280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:3280:EDES NPP MS")
  field(INPB, "XCOR:UNDH:3280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:3380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:3380:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:3380:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:3380:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:3380:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:3380:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:3380:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:3380:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:3380:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:3380:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:3380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:3380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:3380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:3380:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:3380:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:3380:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:3380:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:3380:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:3380:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:3380:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:3380:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:3380:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:3380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:3380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:3380:BMAX")
  field(DOL2, "XCOR:UNDH:3380:BMAX")
  field(DOL3, "XCOR:UNDH:3380:BMAX")
  field(DOL4, "XCOR:UNDH:3380:BMIN")
  field(DOL5, "XCOR:UNDH:3380:BMIN")
  field(DOL6, "XCOR:UNDH:3380:BMIN")
  field(LNK1, "XCOR:UNDH:3380:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:3380:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:3380:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:3380:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:3380:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:3380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:3380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:3380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:3380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:3380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:3380:EDES NPP MS")
  field(INPB, "XCOR:UNDH:3380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:3480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:3480:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:3480:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:3480:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:3480:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:3480:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:3480:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:3480:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:3480:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:3480:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:3480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:3480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:3480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:3480:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:3480:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:3480:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:3480:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:3480:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:3480:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:3480:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:3480:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:3480:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:3480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:3480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:3480:BMAX")
  field(DOL2, "XCOR:UNDH:3480:BMAX")
  field(DOL3, "XCOR:UNDH:3480:BMAX")
  field(DOL4, "XCOR:UNDH:3480:BMIN")
  field(DOL5, "XCOR:UNDH:3480:BMIN")
  field(DOL6, "XCOR:UNDH:3480:BMIN")
  field(LNK1, "XCOR:UNDH:3480:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:3480:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:3480:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:3480:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:3480:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:3480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:3480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:3480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:3480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:3480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:3480:EDES NPP MS")
  field(INPB, "XCOR:UNDH:3480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:3580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:3580:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:3580:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:3580:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:3580:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:3580:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:3580:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:3580:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:3580:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:3580:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:3580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:3580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:3580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:3580:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:3580:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:3580:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:3580:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:3580:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:3580:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:3580:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:3580:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:3580:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:3580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:3580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:3580:BMAX")
  field(DOL2, "XCOR:UNDH:3580:BMAX")
  field(DOL3, "XCOR:UNDH:3580:BMAX")
  field(DOL4, "XCOR:UNDH:3580:BMIN")
  field(DOL5, "XCOR:UNDH:3580:BMIN")
  field(DOL6, "XCOR:UNDH:3580:BMIN")
  field(LNK1, "XCOR:UNDH:3580:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:3580:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:3580:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:3580:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:3580:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:3580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:3580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:3580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:3580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:3580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:3580:EDES NPP MS")
  field(INPB, "XCOR:UNDH:3580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:3680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:3680:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:3680:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:3680:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:3680:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:3680:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:3680:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:3680:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:3680:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:3680:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:3680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:3680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:3680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:3680:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:3680:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:3680:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:3680:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:3680:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:3680:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:3680:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:3680:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:3680:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:3680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:3680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:3680:BMAX")
  field(DOL2, "XCOR:UNDH:3680:BMAX")
  field(DOL3, "XCOR:UNDH:3680:BMAX")
  field(DOL4, "XCOR:UNDH:3680:BMIN")
  field(DOL5, "XCOR:UNDH:3680:BMIN")
  field(DOL6, "XCOR:UNDH:3680:BMIN")
  field(LNK1, "XCOR:UNDH:3680:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:3680:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:3680:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:3680:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:3680:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:3680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:3680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:3680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:3680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:3680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:3680:EDES NPP MS")
  field(INPB, "XCOR:UNDH:3680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:3780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:3780:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:3780:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:3780:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:3780:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:3780:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:3780:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:3780:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:3780:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:3780:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:3780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:3780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:3780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:3780:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:3780:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:3780:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:3780:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:3780:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:3780:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:3780:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:3780:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:3780:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:3780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:3780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:3780:BMAX")
  field(DOL2, "XCOR:UNDH:3780:BMAX")
  field(DOL3, "XCOR:UNDH:3780:BMAX")
  field(DOL4, "XCOR:UNDH:3780:BMIN")
  field(DOL5, "XCOR:UNDH:3780:BMIN")
  field(DOL6, "XCOR:UNDH:3780:BMIN")
  field(LNK1, "XCOR:UNDH:3780:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:3780:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:3780:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:3780:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:3780:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:3780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:3780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:3780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:3780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:3780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:3780:EDES NPP MS")
  field(INPB, "XCOR:UNDH:3780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:3880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:3880:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:3880:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:3880:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:3880:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:3880:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:3880:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:3880:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:3880:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:3880:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:3880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:3880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:3880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:3880:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:3880:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:3880:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:3880:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:3880:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:3880:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:3880:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:3880:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:3880:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:3880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:3880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:3880:BMAX")
  field(DOL2, "XCOR:UNDH:3880:BMAX")
  field(DOL3, "XCOR:UNDH:3880:BMAX")
  field(DOL4, "XCOR:UNDH:3880:BMIN")
  field(DOL5, "XCOR:UNDH:3880:BMIN")
  field(DOL6, "XCOR:UNDH:3880:BMIN")
  field(LNK1, "XCOR:UNDH:3880:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:3880:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:3880:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:3880:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:3880:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:3880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:3880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:3880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:3880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:3880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:3880:EDES NPP MS")
  field(INPB, "XCOR:UNDH:3880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:3980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:3980:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:3980:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:3980:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:3980:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:3980:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:3980:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:3980:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:3980:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:3980:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:3980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:3980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:3980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:3980:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:3980:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:3980:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:3980:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:3980:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:3980:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:3980:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:3980:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:3980:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:3980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:3980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:3980:BMAX")
  field(DOL2, "XCOR:UNDH:3980:BMAX")
  field(DOL3, "XCOR:UNDH:3980:BMAX")
  field(DOL4, "XCOR:UNDH:3980:BMIN")
  field(DOL5, "XCOR:UNDH:3980:BMIN")
  field(DOL6, "XCOR:UNDH:3980:BMIN")
  field(LNK1, "XCOR:UNDH:3980:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:3980:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:3980:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:3980:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:3980:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:3980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:3980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:3980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:3980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:3980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:3980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:3980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:3980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:3980:EDES NPP MS")
  field(INPB, "XCOR:UNDH:3980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:4080:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:4080:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:4080:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:4080:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:4080:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:4080:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:4080:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:4080:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:4080:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:4080:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:4080:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:4080:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:4080:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:4080:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:4080:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:4080:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:4080:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:4080:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:4080:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:4080:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:4080:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:4080:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:4080:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:4080:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:4080:BMAX")
  field(DOL2, "XCOR:UNDH:4080:BMAX")
  field(DOL3, "XCOR:UNDH:4080:BMAX")
  field(DOL4, "XCOR:UNDH:4080:BMIN")
  field(DOL5, "XCOR:UNDH:4080:BMIN")
  field(DOL6, "XCOR:UNDH:4080:BMIN")
  field(LNK1, "XCOR:UNDH:4080:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:4080:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:4080:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:4080:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:4080:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:4080:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4080:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4080:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:4080:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:4080:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:4080:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4080:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4080:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4080:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4080:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4080:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:4080:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:4080:EDES NPP MS")
  field(INPB, "XCOR:UNDH:4080:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:4180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:4180:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:4180:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:4180:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:4180:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:4180:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:4180:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:4180:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:4180:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:4180:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:4180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:4180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:4180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:4180:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:4180:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:4180:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:4180:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:4180:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:4180:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:4180:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:4180:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:4180:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:4180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:4180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:4180:BMAX")
  field(DOL2, "XCOR:UNDH:4180:BMAX")
  field(DOL3, "XCOR:UNDH:4180:BMAX")
  field(DOL4, "XCOR:UNDH:4180:BMIN")
  field(DOL5, "XCOR:UNDH:4180:BMIN")
  field(DOL6, "XCOR:UNDH:4180:BMIN")
  field(LNK1, "XCOR:UNDH:4180:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:4180:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:4180:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:4180:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:4180:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:4180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:4180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:4180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:4180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:4180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:4180:EDES NPP MS")
  field(INPB, "XCOR:UNDH:4180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:4280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:4280:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:4280:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:4280:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:4280:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:4280:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:4280:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:4280:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:4280:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:4280:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:4280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:4280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:4280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:4280:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:4280:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:4280:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:4280:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:4280:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:4280:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:4280:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:4280:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:4280:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:4280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:4280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:4280:BMAX")
  field(DOL2, "XCOR:UNDH:4280:BMAX")
  field(DOL3, "XCOR:UNDH:4280:BMAX")
  field(DOL4, "XCOR:UNDH:4280:BMIN")
  field(DOL5, "XCOR:UNDH:4280:BMIN")
  field(DOL6, "XCOR:UNDH:4280:BMIN")
  field(LNK1, "XCOR:UNDH:4280:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:4280:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:4280:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:4280:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:4280:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:4280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:4280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:4280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:4280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:4280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:4280:EDES NPP MS")
  field(INPB, "XCOR:UNDH:4280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:4380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:4380:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:4380:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:4380:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:4380:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:4380:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:4380:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:4380:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:4380:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:4380:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:4380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:4380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:4380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:4380:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:4380:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:4380:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:4380:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:4380:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:4380:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:4380:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:4380:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:4380:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:4380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:4380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:4380:BMAX")
  field(DOL2, "XCOR:UNDH:4380:BMAX")
  field(DOL3, "XCOR:UNDH:4380:BMAX")
  field(DOL4, "XCOR:UNDH:4380:BMIN")
  field(DOL5, "XCOR:UNDH:4380:BMIN")
  field(DOL6, "XCOR:UNDH:4380:BMIN")
  field(LNK1, "XCOR:UNDH:4380:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:4380:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:4380:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:4380:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:4380:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:4380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:4380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:4380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:4380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:4380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:4380:EDES NPP MS")
  field(INPB, "XCOR:UNDH:4380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:4480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:4480:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:4480:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:4480:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:4480:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:4480:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:4480:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:4480:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:4480:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:4480:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:4480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:4480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:4480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:4480:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:4480:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:4480:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:4480:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:4480:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:4480:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:4480:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:4480:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:4480:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:4480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:4480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:4480:BMAX")
  field(DOL2, "XCOR:UNDH:4480:BMAX")
  field(DOL3, "XCOR:UNDH:4480:BMAX")
  field(DOL4, "XCOR:UNDH:4480:BMIN")
  field(DOL5, "XCOR:UNDH:4480:BMIN")
  field(DOL6, "XCOR:UNDH:4480:BMIN")
  field(LNK1, "XCOR:UNDH:4480:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:4480:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:4480:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:4480:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:4480:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:4480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:4480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:4480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:4480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:4480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:4480:EDES NPP MS")
  field(INPB, "XCOR:UNDH:4480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:4580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:4580:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:4580:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:4580:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:4580:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:4580:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:4580:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:4580:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:4580:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:4580:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:4580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:4580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:4580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:4580:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:4580:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:4580:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:4580:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:4580:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:4580:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:4580:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:4580:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:4580:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:4580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:4580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:4580:BMAX")
  field(DOL2, "XCOR:UNDH:4580:BMAX")
  field(DOL3, "XCOR:UNDH:4580:BMAX")
  field(DOL4, "XCOR:UNDH:4580:BMIN")
  field(DOL5, "XCOR:UNDH:4580:BMIN")
  field(DOL6, "XCOR:UNDH:4580:BMIN")
  field(LNK1, "XCOR:UNDH:4580:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:4580:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:4580:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:4580:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:4580:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:4580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:4580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:4580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:4580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:4580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:4580:EDES NPP MS")
  field(INPB, "XCOR:UNDH:4580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:4680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:4680:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:4680:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:4680:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:4680:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:4680:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:4680:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:4680:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:4680:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:4680:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:4680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:4680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:4680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:4680:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:4680:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:4680:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:4680:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:4680:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:4680:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:4680:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:4680:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:4680:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:4680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:4680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:4680:BMAX")
  field(DOL2, "XCOR:UNDH:4680:BMAX")
  field(DOL3, "XCOR:UNDH:4680:BMAX")
  field(DOL4, "XCOR:UNDH:4680:BMIN")
  field(DOL5, "XCOR:UNDH:4680:BMIN")
  field(DOL6, "XCOR:UNDH:4680:BMIN")
  field(LNK1, "XCOR:UNDH:4680:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:4680:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:4680:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:4680:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:4680:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:4680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:4680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:4680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:4680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:4680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:4680:EDES NPP MS")
  field(INPB, "XCOR:UNDH:4680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDH:4780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDH:4780:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDH:4780:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDH:4780:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDH:4780:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDH:4780:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDH:4780:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDH:4780:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDH:4780:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDH:4780:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDH:4780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDH:4780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDH:4780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDH:4780:EDES.PROC PP")
    field(LNK2, "XCOR:UNDH:4780:EACT.PROC PP")
    field(LNK3, "XCOR:UNDH:4780:EERR.DISA PP")
    field(LNK4, "XCOR:UNDH:4780:ECON.PROC PP")
    field(LNK5, "XCOR:UNDH:4780:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDH:4780:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDH:4780:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDH:4780:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDH:4780:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDH:4780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDH:4780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDH:4780:BMAX")
  field(DOL2, "XCOR:UNDH:4780:BMAX")
  field(DOL3, "XCOR:UNDH:4780:BMAX")
  field(DOL4, "XCOR:UNDH:4780:BMIN")
  field(DOL5, "XCOR:UNDH:4780:BMIN")
  field(DOL6, "XCOR:UNDH:4780:BMIN")
  field(LNK1, "XCOR:UNDH:4780:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDH:4780:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDH:4780:BLEM.HOPR")
  field(LNK4, "XCOR:UNDH:4780:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDH:4780:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDH:4780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDH:4780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDH:4780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDH:4780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDH:4780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDH:4780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDH:4780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDH:4780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDH:4780:EDES NPP MS")
  field(INPB, "XCOR:UNDH:4780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:1380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:1380:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:1380:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:1380:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:1380:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:1380:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:1380:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:1380:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:1380:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:1380:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:1380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:1380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:1380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:1380:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:1380:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:1380:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:1380:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:1380:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:1380:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:1380:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:1380:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:1380:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:1380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:1380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:1380:BMAX")
  field(DOL2, "YCOR:UNDH:1380:BMAX")
  field(DOL3, "YCOR:UNDH:1380:BMAX")
  field(DOL4, "YCOR:UNDH:1380:BMIN")
  field(DOL5, "YCOR:UNDH:1380:BMIN")
  field(DOL6, "YCOR:UNDH:1380:BMIN")
  field(LNK1, "YCOR:UNDH:1380:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:1380:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:1380:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:1380:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:1380:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:1380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:1380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:1380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:1380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:1380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:1380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:1380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:1380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:1380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:1380:EDES NPP MS")
  field(INPB, "YCOR:UNDH:1380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:1480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:1480:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:1480:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:1480:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:1480:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:1480:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:1480:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:1480:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:1480:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:1480:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:1480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:1480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:1480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:1480:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:1480:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:1480:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:1480:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:1480:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:1480:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:1480:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:1480:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:1480:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:1480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:1480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:1480:BMAX")
  field(DOL2, "YCOR:UNDH:1480:BMAX")
  field(DOL3, "YCOR:UNDH:1480:BMAX")
  field(DOL4, "YCOR:UNDH:1480:BMIN")
  field(DOL5, "YCOR:UNDH:1480:BMIN")
  field(DOL6, "YCOR:UNDH:1480:BMIN")
  field(LNK1, "YCOR:UNDH:1480:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:1480:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:1480:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:1480:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:1480:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:1480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:1480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:1480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:1480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:1480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:1480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:1480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:1480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:1480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:1480:EDES NPP MS")
  field(INPB, "YCOR:UNDH:1480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:1580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:1580:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:1580:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:1580:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:1580:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:1580:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:1580:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:1580:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:1580:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:1580:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:1580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:1580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:1580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:1580:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:1580:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:1580:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:1580:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:1580:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:1580:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:1580:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:1580:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:1580:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:1580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:1580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:1580:BMAX")
  field(DOL2, "YCOR:UNDH:1580:BMAX")
  field(DOL3, "YCOR:UNDH:1580:BMAX")
  field(DOL4, "YCOR:UNDH:1580:BMIN")
  field(DOL5, "YCOR:UNDH:1580:BMIN")
  field(DOL6, "YCOR:UNDH:1580:BMIN")
  field(LNK1, "YCOR:UNDH:1580:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:1580:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:1580:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:1580:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:1580:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:1580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:1580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:1580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:1580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:1580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:1580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:1580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:1580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:1580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:1580:EDES NPP MS")
  field(INPB, "YCOR:UNDH:1580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:1680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:1680:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:1680:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:1680:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:1680:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:1680:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:1680:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:1680:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:1680:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:1680:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:1680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:1680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:1680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:1680:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:1680:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:1680:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:1680:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:1680:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:1680:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:1680:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:1680:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:1680:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:1680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:1680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:1680:BMAX")
  field(DOL2, "YCOR:UNDH:1680:BMAX")
  field(DOL3, "YCOR:UNDH:1680:BMAX")
  field(DOL4, "YCOR:UNDH:1680:BMIN")
  field(DOL5, "YCOR:UNDH:1680:BMIN")
  field(DOL6, "YCOR:UNDH:1680:BMIN")
  field(LNK1, "YCOR:UNDH:1680:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:1680:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:1680:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:1680:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:1680:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:1680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:1680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:1680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:1680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:1680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:1680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:1680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:1680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:1680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:1680:EDES NPP MS")
  field(INPB, "YCOR:UNDH:1680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:1780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:1780:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:1780:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:1780:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:1780:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:1780:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:1780:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:1780:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:1780:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:1780:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:1780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:1780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:1780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:1780:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:1780:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:1780:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:1780:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:1780:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:1780:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:1780:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:1780:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:1780:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:1780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:1780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:1780:BMAX")
  field(DOL2, "YCOR:UNDH:1780:BMAX")
  field(DOL3, "YCOR:UNDH:1780:BMAX")
  field(DOL4, "YCOR:UNDH:1780:BMIN")
  field(DOL5, "YCOR:UNDH:1780:BMIN")
  field(DOL6, "YCOR:UNDH:1780:BMIN")
  field(LNK1, "YCOR:UNDH:1780:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:1780:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:1780:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:1780:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:1780:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:1780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:1780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:1780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:1780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:1780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:1780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:1780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:1780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:1780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:1780:EDES NPP MS")
  field(INPB, "YCOR:UNDH:1780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:1880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:1880:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:1880:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:1880:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:1880:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:1880:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:1880:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:1880:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:1880:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:1880:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:1880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:1880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:1880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:1880:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:1880:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:1880:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:1880:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:1880:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:1880:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:1880:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:1880:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:1880:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:1880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:1880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:1880:BMAX")
  field(DOL2, "YCOR:UNDH:1880:BMAX")
  field(DOL3, "YCOR:UNDH:1880:BMAX")
  field(DOL4, "YCOR:UNDH:1880:BMIN")
  field(DOL5, "YCOR:UNDH:1880:BMIN")
  field(DOL6, "YCOR:UNDH:1880:BMIN")
  field(LNK1, "YCOR:UNDH:1880:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:1880:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:1880:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:1880:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:1880:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:1880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:1880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:1880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:1880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:1880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:1880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:1880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:1880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:1880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:1880:EDES NPP MS")
  field(INPB, "YCOR:UNDH:1880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:1980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:1980:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:1980:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:1980:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:1980:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:1980:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:1980:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:1980:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:1980:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:1980:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:1980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:1980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:1980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:1980:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:1980:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:1980:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:1980:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:1980:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:1980:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:1980:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:1980:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:1980:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:1980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:1980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:1980:BMAX")
  field(DOL2, "YCOR:UNDH:1980:BMAX")
  field(DOL3, "YCOR:UNDH:1980:BMAX")
  field(DOL4, "YCOR:UNDH:1980:BMIN")
  field(DOL5, "YCOR:UNDH:1980:BMIN")
  field(DOL6, "YCOR:UNDH:1980:BMIN")
  field(LNK1, "YCOR:UNDH:1980:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:1980:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:1980:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:1980:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:1980:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:1980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:1980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:1980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:1980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:1980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:1980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:1980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:1980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:1980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:1980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:1980:EDES NPP MS")
  field(INPB, "YCOR:UNDH:1980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:2080:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:2080:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:2080:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:2080:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:2080:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:2080:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:2080:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:2080:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:2080:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:2080:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:2080:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:2080:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:2080:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:2080:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:2080:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:2080:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:2080:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:2080:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:2080:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:2080:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:2080:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:2080:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:2080:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:2080:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:2080:BMAX")
  field(DOL2, "YCOR:UNDH:2080:BMAX")
  field(DOL3, "YCOR:UNDH:2080:BMAX")
  field(DOL4, "YCOR:UNDH:2080:BMIN")
  field(DOL5, "YCOR:UNDH:2080:BMIN")
  field(DOL6, "YCOR:UNDH:2080:BMIN")
  field(LNK1, "YCOR:UNDH:2080:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:2080:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:2080:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:2080:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:2080:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:2080:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2080:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2080:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:2080:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:2080:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:2080:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2080:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2080:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2080:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2080:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2080:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:2080:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:2080:EDES NPP MS")
  field(INPB, "YCOR:UNDH:2080:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:2180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:2180:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:2180:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:2180:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:2180:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:2180:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:2180:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:2180:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:2180:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:2180:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:2180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:2180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:2180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:2180:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:2180:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:2180:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:2180:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:2180:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:2180:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:2180:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:2180:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:2180:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:2180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:2180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:2180:BMAX")
  field(DOL2, "YCOR:UNDH:2180:BMAX")
  field(DOL3, "YCOR:UNDH:2180:BMAX")
  field(DOL4, "YCOR:UNDH:2180:BMIN")
  field(DOL5, "YCOR:UNDH:2180:BMIN")
  field(DOL6, "YCOR:UNDH:2180:BMIN")
  field(LNK1, "YCOR:UNDH:2180:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:2180:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:2180:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:2180:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:2180:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:2180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:2180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:2180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:2180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:2180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:2180:EDES NPP MS")
  field(INPB, "YCOR:UNDH:2180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:2280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:2280:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:2280:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:2280:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:2280:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:2280:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:2280:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:2280:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:2280:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:2280:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:2280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:2280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:2280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:2280:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:2280:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:2280:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:2280:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:2280:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:2280:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:2280:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:2280:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:2280:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:2280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:2280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:2280:BMAX")
  field(DOL2, "YCOR:UNDH:2280:BMAX")
  field(DOL3, "YCOR:UNDH:2280:BMAX")
  field(DOL4, "YCOR:UNDH:2280:BMIN")
  field(DOL5, "YCOR:UNDH:2280:BMIN")
  field(DOL6, "YCOR:UNDH:2280:BMIN")
  field(LNK1, "YCOR:UNDH:2280:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:2280:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:2280:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:2280:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:2280:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:2280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:2280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:2280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:2280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:2280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:2280:EDES NPP MS")
  field(INPB, "YCOR:UNDH:2280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:2380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:2380:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:2380:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:2380:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:2380:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:2380:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:2380:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:2380:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:2380:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:2380:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:2380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:2380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:2380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:2380:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:2380:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:2380:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:2380:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:2380:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:2380:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:2380:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:2380:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:2380:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:2380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:2380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:2380:BMAX")
  field(DOL2, "YCOR:UNDH:2380:BMAX")
  field(DOL3, "YCOR:UNDH:2380:BMAX")
  field(DOL4, "YCOR:UNDH:2380:BMIN")
  field(DOL5, "YCOR:UNDH:2380:BMIN")
  field(DOL6, "YCOR:UNDH:2380:BMIN")
  field(LNK1, "YCOR:UNDH:2380:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:2380:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:2380:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:2380:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:2380:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:2380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:2380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:2380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:2380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:2380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:2380:EDES NPP MS")
  field(INPB, "YCOR:UNDH:2380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:2480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:2480:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:2480:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:2480:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:2480:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:2480:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:2480:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:2480:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:2480:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:2480:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:2480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:2480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:2480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:2480:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:2480:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:2480:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:2480:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:2480:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:2480:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:2480:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:2480:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:2480:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:2480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:2480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:2480:BMAX")
  field(DOL2, "YCOR:UNDH:2480:BMAX")
  field(DOL3, "YCOR:UNDH:2480:BMAX")
  field(DOL4, "YCOR:UNDH:2480:BMIN")
  field(DOL5, "YCOR:UNDH:2480:BMIN")
  field(DOL6, "YCOR:UNDH:2480:BMIN")
  field(LNK1, "YCOR:UNDH:2480:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:2480:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:2480:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:2480:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:2480:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:2480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:2480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:2480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:2480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:2480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:2480:EDES NPP MS")
  field(INPB, "YCOR:UNDH:2480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:2580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:2580:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:2580:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:2580:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:2580:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:2580:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:2580:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:2580:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:2580:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:2580:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:2580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:2580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:2580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:2580:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:2580:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:2580:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:2580:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:2580:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:2580:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:2580:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:2580:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:2580:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:2580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:2580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:2580:BMAX")
  field(DOL2, "YCOR:UNDH:2580:BMAX")
  field(DOL3, "YCOR:UNDH:2580:BMAX")
  field(DOL4, "YCOR:UNDH:2580:BMIN")
  field(DOL5, "YCOR:UNDH:2580:BMIN")
  field(DOL6, "YCOR:UNDH:2580:BMIN")
  field(LNK1, "YCOR:UNDH:2580:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:2580:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:2580:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:2580:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:2580:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:2580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:2580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:2580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:2580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:2580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:2580:EDES NPP MS")
  field(INPB, "YCOR:UNDH:2580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:2680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:2680:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:2680:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:2680:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:2680:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:2680:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:2680:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:2680:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:2680:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:2680:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:2680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:2680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:2680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:2680:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:2680:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:2680:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:2680:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:2680:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:2680:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:2680:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:2680:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:2680:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:2680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:2680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:2680:BMAX")
  field(DOL2, "YCOR:UNDH:2680:BMAX")
  field(DOL3, "YCOR:UNDH:2680:BMAX")
  field(DOL4, "YCOR:UNDH:2680:BMIN")
  field(DOL5, "YCOR:UNDH:2680:BMIN")
  field(DOL6, "YCOR:UNDH:2680:BMIN")
  field(LNK1, "YCOR:UNDH:2680:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:2680:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:2680:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:2680:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:2680:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:2680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:2680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:2680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:2680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:2680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:2680:EDES NPP MS")
  field(INPB, "YCOR:UNDH:2680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:2780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:2780:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:2780:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:2780:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:2780:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:2780:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:2780:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:2780:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:2780:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:2780:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:2780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:2780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:2780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:2780:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:2780:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:2780:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:2780:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:2780:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:2780:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:2780:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:2780:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:2780:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:2780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:2780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:2780:BMAX")
  field(DOL2, "YCOR:UNDH:2780:BMAX")
  field(DOL3, "YCOR:UNDH:2780:BMAX")
  field(DOL4, "YCOR:UNDH:2780:BMIN")
  field(DOL5, "YCOR:UNDH:2780:BMIN")
  field(DOL6, "YCOR:UNDH:2780:BMIN")
  field(LNK1, "YCOR:UNDH:2780:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:2780:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:2780:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:2780:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:2780:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:2780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:2780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:2780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:2780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:2780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:2780:EDES NPP MS")
  field(INPB, "YCOR:UNDH:2780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:2880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:2880:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:2880:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:2880:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:2880:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:2880:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:2880:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:2880:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:2880:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:2880:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:2880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:2880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:2880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:2880:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:2880:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:2880:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:2880:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:2880:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:2880:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:2880:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:2880:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:2880:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:2880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:2880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:2880:BMAX")
  field(DOL2, "YCOR:UNDH:2880:BMAX")
  field(DOL3, "YCOR:UNDH:2880:BMAX")
  field(DOL4, "YCOR:UNDH:2880:BMIN")
  field(DOL5, "YCOR:UNDH:2880:BMIN")
  field(DOL6, "YCOR:UNDH:2880:BMIN")
  field(LNK1, "YCOR:UNDH:2880:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:2880:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:2880:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:2880:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:2880:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:2880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:2880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:2880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:2880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:2880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:2880:EDES NPP MS")
  field(INPB, "YCOR:UNDH:2880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:2980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:2980:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:2980:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:2980:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:2980:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:2980:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:2980:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:2980:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:2980:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:2980:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:2980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:2980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:2980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:2980:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:2980:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:2980:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:2980:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:2980:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:2980:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:2980:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:2980:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:2980:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:2980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:2980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:2980:BMAX")
  field(DOL2, "YCOR:UNDH:2980:BMAX")
  field(DOL3, "YCOR:UNDH:2980:BMAX")
  field(DOL4, "YCOR:UNDH:2980:BMIN")
  field(DOL5, "YCOR:UNDH:2980:BMIN")
  field(DOL6, "YCOR:UNDH:2980:BMIN")
  field(LNK1, "YCOR:UNDH:2980:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:2980:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:2980:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:2980:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:2980:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:2980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:2980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:2980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:2980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:2980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:2980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:2980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:2980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:2980:EDES NPP MS")
  field(INPB, "YCOR:UNDH:2980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:3080:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:3080:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:3080:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:3080:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:3080:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:3080:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:3080:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:3080:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:3080:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:3080:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:3080:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:3080:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:3080:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:3080:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:3080:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:3080:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:3080:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:3080:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:3080:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:3080:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:3080:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:3080:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:3080:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:3080:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:3080:BMAX")
  field(DOL2, "YCOR:UNDH:3080:BMAX")
  field(DOL3, "YCOR:UNDH:3080:BMAX")
  field(DOL4, "YCOR:UNDH:3080:BMIN")
  field(DOL5, "YCOR:UNDH:3080:BMIN")
  field(DOL6, "YCOR:UNDH:3080:BMIN")
  field(LNK1, "YCOR:UNDH:3080:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:3080:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:3080:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:3080:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:3080:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:3080:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3080:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3080:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:3080:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:3080:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:3080:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3080:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3080:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3080:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3080:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3080:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:3080:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:3080:EDES NPP MS")
  field(INPB, "YCOR:UNDH:3080:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:3180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:3180:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:3180:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:3180:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:3180:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:3180:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:3180:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:3180:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:3180:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:3180:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:3180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:3180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:3180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:3180:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:3180:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:3180:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:3180:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:3180:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:3180:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:3180:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:3180:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:3180:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:3180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:3180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:3180:BMAX")
  field(DOL2, "YCOR:UNDH:3180:BMAX")
  field(DOL3, "YCOR:UNDH:3180:BMAX")
  field(DOL4, "YCOR:UNDH:3180:BMIN")
  field(DOL5, "YCOR:UNDH:3180:BMIN")
  field(DOL6, "YCOR:UNDH:3180:BMIN")
  field(LNK1, "YCOR:UNDH:3180:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:3180:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:3180:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:3180:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:3180:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:3180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:3180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:3180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:3180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:3180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:3180:EDES NPP MS")
  field(INPB, "YCOR:UNDH:3180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:3280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:3280:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:3280:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:3280:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:3280:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:3280:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:3280:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:3280:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:3280:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:3280:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:3280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:3280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:3280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:3280:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:3280:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:3280:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:3280:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:3280:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:3280:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:3280:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:3280:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:3280:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:3280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:3280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:3280:BMAX")
  field(DOL2, "YCOR:UNDH:3280:BMAX")
  field(DOL3, "YCOR:UNDH:3280:BMAX")
  field(DOL4, "YCOR:UNDH:3280:BMIN")
  field(DOL5, "YCOR:UNDH:3280:BMIN")
  field(DOL6, "YCOR:UNDH:3280:BMIN")
  field(LNK1, "YCOR:UNDH:3280:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:3280:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:3280:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:3280:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:3280:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:3280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:3280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:3280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:3280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:3280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:3280:EDES NPP MS")
  field(INPB, "YCOR:UNDH:3280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:3380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:3380:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:3380:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:3380:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:3380:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:3380:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:3380:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:3380:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:3380:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:3380:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:3380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:3380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:3380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:3380:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:3380:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:3380:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:3380:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:3380:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:3380:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:3380:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:3380:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:3380:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:3380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:3380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:3380:BMAX")
  field(DOL2, "YCOR:UNDH:3380:BMAX")
  field(DOL3, "YCOR:UNDH:3380:BMAX")
  field(DOL4, "YCOR:UNDH:3380:BMIN")
  field(DOL5, "YCOR:UNDH:3380:BMIN")
  field(DOL6, "YCOR:UNDH:3380:BMIN")
  field(LNK1, "YCOR:UNDH:3380:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:3380:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:3380:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:3380:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:3380:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:3380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:3380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:3380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:3380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:3380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:3380:EDES NPP MS")
  field(INPB, "YCOR:UNDH:3380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:3480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:3480:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:3480:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:3480:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:3480:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:3480:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:3480:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:3480:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:3480:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:3480:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:3480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:3480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:3480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:3480:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:3480:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:3480:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:3480:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:3480:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:3480:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:3480:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:3480:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:3480:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:3480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:3480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:3480:BMAX")
  field(DOL2, "YCOR:UNDH:3480:BMAX")
  field(DOL3, "YCOR:UNDH:3480:BMAX")
  field(DOL4, "YCOR:UNDH:3480:BMIN")
  field(DOL5, "YCOR:UNDH:3480:BMIN")
  field(DOL6, "YCOR:UNDH:3480:BMIN")
  field(LNK1, "YCOR:UNDH:3480:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:3480:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:3480:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:3480:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:3480:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:3480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:3480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:3480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:3480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:3480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:3480:EDES NPP MS")
  field(INPB, "YCOR:UNDH:3480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:3580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:3580:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:3580:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:3580:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:3580:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:3580:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:3580:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:3580:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:3580:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:3580:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:3580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:3580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:3580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:3580:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:3580:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:3580:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:3580:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:3580:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:3580:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:3580:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:3580:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:3580:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:3580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:3580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:3580:BMAX")
  field(DOL2, "YCOR:UNDH:3580:BMAX")
  field(DOL3, "YCOR:UNDH:3580:BMAX")
  field(DOL4, "YCOR:UNDH:3580:BMIN")
  field(DOL5, "YCOR:UNDH:3580:BMIN")
  field(DOL6, "YCOR:UNDH:3580:BMIN")
  field(LNK1, "YCOR:UNDH:3580:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:3580:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:3580:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:3580:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:3580:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:3580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:3580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:3580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:3580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:3580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:3580:EDES NPP MS")
  field(INPB, "YCOR:UNDH:3580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:3680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:3680:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:3680:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:3680:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:3680:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:3680:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:3680:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:3680:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:3680:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:3680:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:3680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:3680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:3680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:3680:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:3680:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:3680:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:3680:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:3680:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:3680:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:3680:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:3680:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:3680:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:3680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:3680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:3680:BMAX")
  field(DOL2, "YCOR:UNDH:3680:BMAX")
  field(DOL3, "YCOR:UNDH:3680:BMAX")
  field(DOL4, "YCOR:UNDH:3680:BMIN")
  field(DOL5, "YCOR:UNDH:3680:BMIN")
  field(DOL6, "YCOR:UNDH:3680:BMIN")
  field(LNK1, "YCOR:UNDH:3680:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:3680:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:3680:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:3680:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:3680:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:3680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:3680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:3680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:3680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:3680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:3680:EDES NPP MS")
  field(INPB, "YCOR:UNDH:3680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:3780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:3780:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:3780:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:3780:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:3780:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:3780:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:3780:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:3780:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:3780:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:3780:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:3780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:3780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:3780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:3780:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:3780:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:3780:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:3780:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:3780:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:3780:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:3780:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:3780:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:3780:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:3780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:3780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:3780:BMAX")
  field(DOL2, "YCOR:UNDH:3780:BMAX")
  field(DOL3, "YCOR:UNDH:3780:BMAX")
  field(DOL4, "YCOR:UNDH:3780:BMIN")
  field(DOL5, "YCOR:UNDH:3780:BMIN")
  field(DOL6, "YCOR:UNDH:3780:BMIN")
  field(LNK1, "YCOR:UNDH:3780:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:3780:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:3780:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:3780:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:3780:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:3780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:3780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:3780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:3780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:3780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:3780:EDES NPP MS")
  field(INPB, "YCOR:UNDH:3780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:3880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:3880:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:3880:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:3880:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:3880:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:3880:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:3880:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:3880:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:3880:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:3880:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:3880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:3880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:3880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:3880:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:3880:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:3880:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:3880:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:3880:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:3880:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:3880:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:3880:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:3880:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:3880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:3880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:3880:BMAX")
  field(DOL2, "YCOR:UNDH:3880:BMAX")
  field(DOL3, "YCOR:UNDH:3880:BMAX")
  field(DOL4, "YCOR:UNDH:3880:BMIN")
  field(DOL5, "YCOR:UNDH:3880:BMIN")
  field(DOL6, "YCOR:UNDH:3880:BMIN")
  field(LNK1, "YCOR:UNDH:3880:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:3880:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:3880:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:3880:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:3880:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:3880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:3880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:3880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:3880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:3880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:3880:EDES NPP MS")
  field(INPB, "YCOR:UNDH:3880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:3980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:3980:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:3980:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:3980:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:3980:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:3980:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:3980:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:3980:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:3980:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:3980:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:3980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:3980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:3980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:3980:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:3980:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:3980:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:3980:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:3980:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:3980:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:3980:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:3980:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:3980:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:3980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:3980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:3980:BMAX")
  field(DOL2, "YCOR:UNDH:3980:BMAX")
  field(DOL3, "YCOR:UNDH:3980:BMAX")
  field(DOL4, "YCOR:UNDH:3980:BMIN")
  field(DOL5, "YCOR:UNDH:3980:BMIN")
  field(DOL6, "YCOR:UNDH:3980:BMIN")
  field(LNK1, "YCOR:UNDH:3980:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:3980:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:3980:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:3980:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:3980:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:3980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:3980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:3980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:3980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:3980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:3980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:3980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:3980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:3980:EDES NPP MS")
  field(INPB, "YCOR:UNDH:3980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:4080:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:4080:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:4080:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:4080:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:4080:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:4080:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:4080:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:4080:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:4080:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:4080:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:4080:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:4080:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:4080:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:4080:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:4080:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:4080:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:4080:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:4080:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:4080:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:4080:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:4080:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:4080:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:4080:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:4080:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:4080:BMAX")
  field(DOL2, "YCOR:UNDH:4080:BMAX")
  field(DOL3, "YCOR:UNDH:4080:BMAX")
  field(DOL4, "YCOR:UNDH:4080:BMIN")
  field(DOL5, "YCOR:UNDH:4080:BMIN")
  field(DOL6, "YCOR:UNDH:4080:BMIN")
  field(LNK1, "YCOR:UNDH:4080:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:4080:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:4080:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:4080:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:4080:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:4080:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4080:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4080:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:4080:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:4080:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:4080:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4080:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4080:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4080:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4080:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4080:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:4080:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:4080:EDES NPP MS")
  field(INPB, "YCOR:UNDH:4080:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:4180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:4180:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:4180:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:4180:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:4180:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:4180:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:4180:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:4180:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:4180:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:4180:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:4180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:4180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:4180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:4180:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:4180:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:4180:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:4180:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:4180:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:4180:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:4180:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:4180:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:4180:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:4180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:4180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:4180:BMAX")
  field(DOL2, "YCOR:UNDH:4180:BMAX")
  field(DOL3, "YCOR:UNDH:4180:BMAX")
  field(DOL4, "YCOR:UNDH:4180:BMIN")
  field(DOL5, "YCOR:UNDH:4180:BMIN")
  field(DOL6, "YCOR:UNDH:4180:BMIN")
  field(LNK1, "YCOR:UNDH:4180:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:4180:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:4180:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:4180:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:4180:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:4180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:4180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:4180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:4180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:4180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:4180:EDES NPP MS")
  field(INPB, "YCOR:UNDH:4180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:4280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:4280:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:4280:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:4280:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:4280:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:4280:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:4280:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:4280:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:4280:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:4280:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:4280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:4280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:4280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:4280:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:4280:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:4280:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:4280:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:4280:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:4280:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:4280:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:4280:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:4280:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:4280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:4280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:4280:BMAX")
  field(DOL2, "YCOR:UNDH:4280:BMAX")
  field(DOL3, "YCOR:UNDH:4280:BMAX")
  field(DOL4, "YCOR:UNDH:4280:BMIN")
  field(DOL5, "YCOR:UNDH:4280:BMIN")
  field(DOL6, "YCOR:UNDH:4280:BMIN")
  field(LNK1, "YCOR:UNDH:4280:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:4280:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:4280:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:4280:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:4280:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:4280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:4280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:4280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:4280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:4280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:4280:EDES NPP MS")
  field(INPB, "YCOR:UNDH:4280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:4380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:4380:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:4380:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:4380:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:4380:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:4380:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:4380:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:4380:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:4380:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:4380:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:4380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:4380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:4380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:4380:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:4380:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:4380:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:4380:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:4380:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:4380:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:4380:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:4380:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:4380:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:4380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:4380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:4380:BMAX")
  field(DOL2, "YCOR:UNDH:4380:BMAX")
  field(DOL3, "YCOR:UNDH:4380:BMAX")
  field(DOL4, "YCOR:UNDH:4380:BMIN")
  field(DOL5, "YCOR:UNDH:4380:BMIN")
  field(DOL6, "YCOR:UNDH:4380:BMIN")
  field(LNK1, "YCOR:UNDH:4380:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:4380:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:4380:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:4380:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:4380:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:4380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:4380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:4380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:4380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:4380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:4380:EDES NPP MS")
  field(INPB, "YCOR:UNDH:4380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:4480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:4480:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:4480:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:4480:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:4480:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:4480:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:4480:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:4480:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:4480:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:4480:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:4480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:4480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:4480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:4480:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:4480:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:4480:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:4480:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:4480:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:4480:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:4480:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:4480:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:4480:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:4480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:4480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:4480:BMAX")
  field(DOL2, "YCOR:UNDH:4480:BMAX")
  field(DOL3, "YCOR:UNDH:4480:BMAX")
  field(DOL4, "YCOR:UNDH:4480:BMIN")
  field(DOL5, "YCOR:UNDH:4480:BMIN")
  field(DOL6, "YCOR:UNDH:4480:BMIN")
  field(LNK1, "YCOR:UNDH:4480:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:4480:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:4480:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:4480:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:4480:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:4480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:4480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:4480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:4480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:4480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:4480:EDES NPP MS")
  field(INPB, "YCOR:UNDH:4480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:4580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:4580:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:4580:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:4580:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:4580:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:4580:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:4580:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:4580:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:4580:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:4580:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:4580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:4580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:4580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:4580:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:4580:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:4580:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:4580:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:4580:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:4580:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:4580:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:4580:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:4580:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:4580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:4580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:4580:BMAX")
  field(DOL2, "YCOR:UNDH:4580:BMAX")
  field(DOL3, "YCOR:UNDH:4580:BMAX")
  field(DOL4, "YCOR:UNDH:4580:BMIN")
  field(DOL5, "YCOR:UNDH:4580:BMIN")
  field(DOL6, "YCOR:UNDH:4580:BMIN")
  field(LNK1, "YCOR:UNDH:4580:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:4580:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:4580:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:4580:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:4580:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:4580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:4580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:4580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:4580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:4580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:4580:EDES NPP MS")
  field(INPB, "YCOR:UNDH:4580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:4680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:4680:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:4680:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:4680:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:4680:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:4680:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:4680:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:4680:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:4680:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:4680:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:4680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:4680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:4680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:4680:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:4680:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:4680:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:4680:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:4680:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:4680:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:4680:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:4680:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:4680:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:4680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:4680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:4680:BMAX")
  field(DOL2, "YCOR:UNDH:4680:BMAX")
  field(DOL3, "YCOR:UNDH:4680:BMAX")
  field(DOL4, "YCOR:UNDH:4680:BMIN")
  field(DOL5, "YCOR:UNDH:4680:BMIN")
  field(DOL6, "YCOR:UNDH:4680:BMIN")
  field(LNK1, "YCOR:UNDH:4680:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:4680:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:4680:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:4680:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:4680:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:4680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:4680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:4680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:4680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:4680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:4680:EDES NPP MS")
  field(INPB, "YCOR:UNDH:4680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDH:4780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDH:4780:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDH:4780:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDH:4780:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDH:4780:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDH:4780:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDH:4780:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDH:4780:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDH:4780:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDH:4780:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDH:4780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDH:4780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDH:4780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDH:4780:EDES.PROC PP")
    field(LNK2, "YCOR:UNDH:4780:EACT.PROC PP")
    field(LNK3, "YCOR:UNDH:4780:EERR.DISA PP")
    field(LNK4, "YCOR:UNDH:4780:ECON.PROC PP")
    field(LNK5, "YCOR:UNDH:4780:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDH:4780:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDH:4780:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDH:4780:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDH:4780:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDH:4780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDH:4780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDH:4780:BMAX")
  field(DOL2, "YCOR:UNDH:4780:BMAX")
  field(DOL3, "YCOR:UNDH:4780:BMAX")
  field(DOL4, "YCOR:UNDH:4780:BMIN")
  field(DOL5, "YCOR:UNDH:4780:BMIN")
  field(DOL6, "YCOR:UNDH:4780:BMIN")
  field(LNK1, "YCOR:UNDH:4780:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDH:4780:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDH:4780:BLEM.HOPR")
  field(LNK4, "YCOR:UNDH:4780:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDH:4780:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDH:4780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDH:4780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDH:4780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDH:4780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDH:4780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDH:4780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDH:4780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDH:4780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDH:4780:EDES NPP MS")
  field(INPB, "YCOR:UNDH:4780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:UNDS:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "LGPS:UNDS:1:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:UNDS:1:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:UNDS:1:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:UNDS:1:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:UNDS:1:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:UNDS:1:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:UNDS:1:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:UNDS:1:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:UNDS:1:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:UNDS:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:UNDS:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:UNDS:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:UNDS:1:EDES.PROC PP")
    field(LNK2, "LGPS:UNDS:1:EACT.PROC PP")
    field(LNK3, "LGPS:UNDS:1:EERR.DISA PP")
    field(LNK4, "LGPS:UNDS:1:ECON.PROC PP")
    field(LNK5, "LGPS:UNDS:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:UNDS:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:UNDS:1:BLEM.PROC PP")
    field(LNK8, "LGPS:UNDS:1:BMOD.PROC PP")
    field(LNK9, "LGPS:UNDS:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:UNDS:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:UNDS:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:UNDS:1:BMAX")
  field(DOL2, "LGPS:UNDS:1:BMAX")
  field(DOL3, "LGPS:UNDS:1:BMAX")
  field(DOL4, "LGPS:UNDS:1:BMIN")
  field(DOL5, "LGPS:UNDS:1:BMIN")
  field(DOL6, "LGPS:UNDS:1:BMIN")
  field(LNK1, "LGPS:UNDS:1:BMAGX.HOPR")
  field(LNK2, "LGPS:UNDS:1:BMAGY.HOPR")
  field(LNK3, "LGPS:UNDS:1:BLEM.HOPR")
  field(LNK4, "LGPS:UNDS:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:UNDS:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:UNDS:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDS:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDS:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:UNDS:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:UNDS:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:UNDS:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDS:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDS:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDS:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDS:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDS:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:UNDS:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:UNDS:1:EDES NPP MS")
  field(INPB, "LGPS:UNDS:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:UNDS:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "LGPS:UNDS:2:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:UNDS:2:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:UNDS:2:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:UNDS:2:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:UNDS:2:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:UNDS:2:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:UNDS:2:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:UNDS:2:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:UNDS:2:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:UNDS:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:UNDS:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:UNDS:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:UNDS:2:EDES.PROC PP")
    field(LNK2, "LGPS:UNDS:2:EACT.PROC PP")
    field(LNK3, "LGPS:UNDS:2:EERR.DISA PP")
    field(LNK4, "LGPS:UNDS:2:ECON.PROC PP")
    field(LNK5, "LGPS:UNDS:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:UNDS:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:UNDS:2:BLEM.PROC PP")
    field(LNK8, "LGPS:UNDS:2:BMOD.PROC PP")
    field(LNK9, "LGPS:UNDS:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:UNDS:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:UNDS:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:UNDS:2:BMAX")
  field(DOL2, "LGPS:UNDS:2:BMAX")
  field(DOL3, "LGPS:UNDS:2:BMAX")
  field(DOL4, "LGPS:UNDS:2:BMIN")
  field(DOL5, "LGPS:UNDS:2:BMIN")
  field(DOL6, "LGPS:UNDS:2:BMIN")
  field(LNK1, "LGPS:UNDS:2:BMAGX.HOPR")
  field(LNK2, "LGPS:UNDS:2:BMAGY.HOPR")
  field(LNK3, "LGPS:UNDS:2:BLEM.HOPR")
  field(LNK4, "LGPS:UNDS:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:UNDS:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:UNDS:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDS:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:UNDS:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:UNDS:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:UNDS:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:UNDS:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDS:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDS:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDS:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:UNDS:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:UNDS:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:UNDS:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:UNDS:2:EDES NPP MS")
  field(INPB, "LGPS:UNDS:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDS:3510:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDS:3510:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDS:3510:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDS:3510:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDS:3510:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDS:3510:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDS:3510:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDS:3510:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDS:3510:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDS:3510:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDS:3510:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDS:3510:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDS:3510:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDS:3510:EDES.PROC PP")
    field(LNK2, "BEND:UNDS:3510:EACT.PROC PP")
    field(LNK3, "BEND:UNDS:3510:EERR.DISA PP")
    field(LNK4, "BEND:UNDS:3510:ECON.PROC PP")
    field(LNK5, "BEND:UNDS:3510:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDS:3510:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDS:3510:BLEM.PROC PP")
    field(LNK8, "BEND:UNDS:3510:BMOD.PROC PP")
    field(LNK9, "BEND:UNDS:3510:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDS:3510:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDS:3510:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDS:3510:BMAX")
  field(DOL2, "BEND:UNDS:3510:BMAX")
  field(DOL3, "BEND:UNDS:3510:BMAX")
  field(DOL4, "BEND:UNDS:3510:BMIN")
  field(DOL5, "BEND:UNDS:3510:BMIN")
  field(DOL6, "BEND:UNDS:3510:BMIN")
  field(LNK1, "BEND:UNDS:3510:BMAGX.HOPR")
  field(LNK2, "BEND:UNDS:3510:BMAGY.HOPR")
  field(LNK3, "BEND:UNDS:3510:BLEM.HOPR")
  field(LNK4, "BEND:UNDS:3510:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDS:3510:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDS:3510:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDS:3510:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDS:3510:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDS:3510:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDS:3510:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDS:3510:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDS:3510:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDS:3510:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:UNDS:3510:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDS:3510:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:UNDS:3510:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDS:3510:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDS:3510:EDES NPP MS")
  field(INPB, "BEND:UNDS:3510:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDS:3510:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDS:3510:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDS:3510:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDS:3510:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDS:3510:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDS:3510:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDS:3510:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDS:3510:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDS:3510:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDS:3510:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDS:3510:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDS:3510:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDS:3510:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDS:3510:EDES.PROC PP")
    field(LNK2, "BTRM:UNDS:3510:EACT.PROC PP")
    field(LNK3, "BTRM:UNDS:3510:EERR.DISA PP")
    field(LNK4, "BTRM:UNDS:3510:ECON.PROC PP")
    field(LNK5, "BTRM:UNDS:3510:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDS:3510:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDS:3510:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDS:3510:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDS:3510:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDS:3510:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDS:3510:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDS:3510:BMAX")
  field(DOL2, "BTRM:UNDS:3510:BMAX")
  field(DOL3, "BTRM:UNDS:3510:BMAX")
  field(DOL4, "BTRM:UNDS:3510:BMIN")
  field(DOL5, "BTRM:UNDS:3510:BMIN")
  field(DOL6, "BTRM:UNDS:3510:BMIN")
  field(LNK1, "BTRM:UNDS:3510:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDS:3510:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDS:3510:BLEM.HOPR")
  field(LNK4, "BTRM:UNDS:3510:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDS:3510:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDS:3510:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDS:3510:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDS:3510:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDS:3510:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amps")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDS:3510:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amps")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDS:3510:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDS:3510:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDS:3510:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDS:3510:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDS:3510:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDS:3510:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDS:3510:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDS:3510:EDES NPP MS")
  field(INPB, "BTRM:UNDS:3510:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDS:3530:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDS:3530:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDS:3530:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDS:3530:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDS:3530:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDS:3530:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDS:3530:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDS:3530:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDS:3530:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDS:3530:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDS:3530:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDS:3530:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDS:3530:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDS:3530:EDES.PROC PP")
    field(LNK2, "BTRM:UNDS:3530:EACT.PROC PP")
    field(LNK3, "BTRM:UNDS:3530:EERR.DISA PP")
    field(LNK4, "BTRM:UNDS:3530:ECON.PROC PP")
    field(LNK5, "BTRM:UNDS:3530:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDS:3530:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDS:3530:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDS:3530:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDS:3530:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDS:3530:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDS:3530:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDS:3530:BMAX")
  field(DOL2, "BTRM:UNDS:3530:BMAX")
  field(DOL3, "BTRM:UNDS:3530:BMAX")
  field(DOL4, "BTRM:UNDS:3530:BMIN")
  field(DOL5, "BTRM:UNDS:3530:BMIN")
  field(DOL6, "BTRM:UNDS:3530:BMIN")
  field(LNK1, "BTRM:UNDS:3530:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDS:3530:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDS:3530:BLEM.HOPR")
  field(LNK4, "BTRM:UNDS:3530:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDS:3530:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDS:3530:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDS:3530:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDS:3530:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDS:3530:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amps")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDS:3530:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amps")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDS:3530:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDS:3530:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDS:3530:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDS:3530:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDS:3530:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDS:3530:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDS:3530:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDS:3530:EDES NPP MS")
  field(INPB, "BTRM:UNDS:3530:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDS:3550:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDS:3550:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDS:3550:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDS:3550:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDS:3550:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDS:3550:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDS:3550:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDS:3550:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDS:3550:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDS:3550:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDS:3550:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDS:3550:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDS:3550:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDS:3550:EDES.PROC PP")
    field(LNK2, "BTRM:UNDS:3550:EACT.PROC PP")
    field(LNK3, "BTRM:UNDS:3550:EERR.DISA PP")
    field(LNK4, "BTRM:UNDS:3550:ECON.PROC PP")
    field(LNK5, "BTRM:UNDS:3550:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDS:3550:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDS:3550:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDS:3550:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDS:3550:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDS:3550:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDS:3550:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDS:3550:BMAX")
  field(DOL2, "BTRM:UNDS:3550:BMAX")
  field(DOL3, "BTRM:UNDS:3550:BMAX")
  field(DOL4, "BTRM:UNDS:3550:BMIN")
  field(DOL5, "BTRM:UNDS:3550:BMIN")
  field(DOL6, "BTRM:UNDS:3550:BMIN")
  field(LNK1, "BTRM:UNDS:3550:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDS:3550:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDS:3550:BLEM.HOPR")
  field(LNK4, "BTRM:UNDS:3550:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDS:3550:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDS:3550:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDS:3550:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDS:3550:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDS:3550:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amps")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDS:3550:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amps")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDS:3550:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDS:3550:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDS:3550:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDS:3550:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDS:3550:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDS:3550:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDS:3550:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDS:3550:EDES NPP MS")
  field(INPB, "BTRM:UNDS:3550:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:UNDS:3570:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "BTRM:UNDS:3570:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:UNDS:3570:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:UNDS:3570:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:UNDS:3570:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:UNDS:3570:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:UNDS:3570:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:UNDS:3570:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:UNDS:3570:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:UNDS:3570:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:UNDS:3570:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:UNDS:3570:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:UNDS:3570:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:UNDS:3570:EDES.PROC PP")
    field(LNK2, "BTRM:UNDS:3570:EACT.PROC PP")
    field(LNK3, "BTRM:UNDS:3570:EERR.DISA PP")
    field(LNK4, "BTRM:UNDS:3570:ECON.PROC PP")
    field(LNK5, "BTRM:UNDS:3570:BMAGX.PROC PP")
    field(LNK6, "BTRM:UNDS:3570:BMAGY.PROC PP")
    field(LNK7, "BTRM:UNDS:3570:BLEM.PROC PP")
    field(LNK8, "BTRM:UNDS:3570:BMOD.PROC PP")
    field(LNK9, "BTRM:UNDS:3570:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:UNDS:3570:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:UNDS:3570:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:UNDS:3570:BMAX")
  field(DOL2, "BTRM:UNDS:3570:BMAX")
  field(DOL3, "BTRM:UNDS:3570:BMAX")
  field(DOL4, "BTRM:UNDS:3570:BMIN")
  field(DOL5, "BTRM:UNDS:3570:BMIN")
  field(DOL6, "BTRM:UNDS:3570:BMIN")
  field(LNK1, "BTRM:UNDS:3570:BMAGX.HOPR")
  field(LNK2, "BTRM:UNDS:3570:BMAGY.HOPR")
  field(LNK3, "BTRM:UNDS:3570:BLEM.HOPR")
  field(LNK4, "BTRM:UNDS:3570:BMAGX.LOPR PP")
  field(LNK5, "BTRM:UNDS:3570:BMAGY.LOPR PP")
  field(LNK6, "BTRM:UNDS:3570:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDS:3570:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:UNDS:3570:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:UNDS:3570:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amps")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:UNDS:3570:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amps")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:UNDS:3570:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDS:3570:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDS:3570:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDS:3570:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:UNDS:3570:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:UNDS:3570:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:UNDS:3570:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:UNDS:3570:EDES NPP MS")
  field(INPB, "BTRM:UNDS:3570:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:1680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:1680:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:1680:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:1680:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:1680:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:1680:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:1680:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:1680:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:1680:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:1680:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:1680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:1680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:1680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:1680:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:1680:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:1680:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:1680:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:1680:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:1680:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:1680:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:1680:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:1680:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:1680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:1680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:1680:BMAX")
  field(DOL2, "QUAD:UNDS:1680:BMAX")
  field(DOL3, "QUAD:UNDS:1680:BMAX")
  field(DOL4, "QUAD:UNDS:1680:BMIN")
  field(DOL5, "QUAD:UNDS:1680:BMIN")
  field(DOL6, "QUAD:UNDS:1680:BMIN")
  field(LNK1, "QUAD:UNDS:1680:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:1680:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:1680:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:1680:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:1680:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:1680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:1680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:1680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:1680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:1680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:1680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:1680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:1680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:1680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:1680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:1680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:1680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:1680:EDES NPP MS")
  field(INPB, "QUAD:UNDS:1680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:1980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:1980:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:1980:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:1980:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:1980:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:1980:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:1980:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:1980:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:1980:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:1980:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:1980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:1980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:1980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:1980:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:1980:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:1980:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:1980:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:1980:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:1980:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:1980:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:1980:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:1980:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:1980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:1980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:1980:BMAX")
  field(DOL2, "QUAD:UNDS:1980:BMAX")
  field(DOL3, "QUAD:UNDS:1980:BMAX")
  field(DOL4, "QUAD:UNDS:1980:BMIN")
  field(DOL5, "QUAD:UNDS:1980:BMIN")
  field(DOL6, "QUAD:UNDS:1980:BMIN")
  field(LNK1, "QUAD:UNDS:1980:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:1980:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:1980:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:1980:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:1980:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:1980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:1980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:1980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:1980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:1980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:1980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:1980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:1980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:1980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:1980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:1980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:1980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:1980:EDES NPP MS")
  field(INPB, "QUAD:UNDS:1980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:2180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:2180:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:2180:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:2180:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:2180:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:2180:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:2180:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:2180:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:2180:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:2180:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:2180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:2180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:2180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:2180:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:2180:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:2180:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:2180:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:2180:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:2180:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:2180:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:2180:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:2180:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:2180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:2180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:2180:BMAX")
  field(DOL2, "QUAD:UNDS:2180:BMAX")
  field(DOL3, "QUAD:UNDS:2180:BMAX")
  field(DOL4, "QUAD:UNDS:2180:BMIN")
  field(DOL5, "QUAD:UNDS:2180:BMIN")
  field(DOL6, "QUAD:UNDS:2180:BMIN")
  field(LNK1, "QUAD:UNDS:2180:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:2180:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:2180:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:2180:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:2180:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:2180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:2180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:2180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:2180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:2180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:2180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:2180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:2180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:2180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:2180:EDES NPP MS")
  field(INPB, "QUAD:UNDS:2180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:2480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:2480:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:2480:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:2480:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:2480:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:2480:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:2480:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:2480:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:2480:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:2480:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:2480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:2480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:2480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:2480:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:2480:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:2480:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:2480:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:2480:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:2480:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:2480:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:2480:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:2480:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:2480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:2480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:2480:BMAX")
  field(DOL2, "QUAD:UNDS:2480:BMAX")
  field(DOL3, "QUAD:UNDS:2480:BMAX")
  field(DOL4, "QUAD:UNDS:2480:BMIN")
  field(DOL5, "QUAD:UNDS:2480:BMIN")
  field(DOL6, "QUAD:UNDS:2480:BMIN")
  field(LNK1, "QUAD:UNDS:2480:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:2480:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:2480:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:2480:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:2480:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:2480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:2480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:2480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:2480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:2480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:2480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:2480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:2480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:2480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:2480:EDES NPP MS")
  field(INPB, "QUAD:UNDS:2480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:2680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:2680:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:2680:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:2680:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:2680:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:2680:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:2680:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:2680:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:2680:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:2680:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:2680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:2680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:2680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:2680:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:2680:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:2680:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:2680:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:2680:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:2680:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:2680:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:2680:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:2680:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:2680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:2680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:2680:BMAX")
  field(DOL2, "QUAD:UNDS:2680:BMAX")
  field(DOL3, "QUAD:UNDS:2680:BMAX")
  field(DOL4, "QUAD:UNDS:2680:BMIN")
  field(DOL5, "QUAD:UNDS:2680:BMIN")
  field(DOL6, "QUAD:UNDS:2680:BMIN")
  field(LNK1, "QUAD:UNDS:2680:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:2680:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:2680:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:2680:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:2680:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:2680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:2680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:2680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:2680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:2680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:2680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:2680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:2680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:2680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:2680:EDES NPP MS")
  field(INPB, "QUAD:UNDS:2680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:2780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:2780:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:2780:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:2780:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:2780:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:2780:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:2780:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:2780:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:2780:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:2780:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:2780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:2780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:2780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:2780:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:2780:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:2780:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:2780:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:2780:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:2780:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:2780:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:2780:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:2780:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:2780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:2780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:2780:BMAX")
  field(DOL2, "QUAD:UNDS:2780:BMAX")
  field(DOL3, "QUAD:UNDS:2780:BMAX")
  field(DOL4, "QUAD:UNDS:2780:BMIN")
  field(DOL5, "QUAD:UNDS:2780:BMIN")
  field(DOL6, "QUAD:UNDS:2780:BMIN")
  field(LNK1, "QUAD:UNDS:2780:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:2780:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:2780:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:2780:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:2780:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:2780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:2780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:2780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:2780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:2780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:2780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:2780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:2780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:2780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:2780:EDES NPP MS")
  field(INPB, "QUAD:UNDS:2780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:2880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:2880:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:2880:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:2880:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:2880:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:2880:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:2880:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:2880:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:2880:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:2880:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:2880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:2880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:2880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:2880:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:2880:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:2880:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:2880:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:2880:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:2880:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:2880:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:2880:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:2880:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:2880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:2880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:2880:BMAX")
  field(DOL2, "QUAD:UNDS:2880:BMAX")
  field(DOL3, "QUAD:UNDS:2880:BMAX")
  field(DOL4, "QUAD:UNDS:2880:BMIN")
  field(DOL5, "QUAD:UNDS:2880:BMIN")
  field(DOL6, "QUAD:UNDS:2880:BMIN")
  field(LNK1, "QUAD:UNDS:2880:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:2880:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:2880:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:2880:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:2880:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:2880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:2880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:2880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:2880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:2880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:2880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:2880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:2880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:2880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:2880:EDES NPP MS")
  field(INPB, "QUAD:UNDS:2880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:2980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:2980:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:2980:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:2980:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:2980:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:2980:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:2980:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:2980:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:2980:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:2980:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:2980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:2980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:2980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:2980:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:2980:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:2980:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:2980:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:2980:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:2980:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:2980:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:2980:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:2980:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:2980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:2980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:2980:BMAX")
  field(DOL2, "QUAD:UNDS:2980:BMAX")
  field(DOL3, "QUAD:UNDS:2980:BMAX")
  field(DOL4, "QUAD:UNDS:2980:BMIN")
  field(DOL5, "QUAD:UNDS:2980:BMIN")
  field(DOL6, "QUAD:UNDS:2980:BMIN")
  field(LNK1, "QUAD:UNDS:2980:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:2980:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:2980:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:2980:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:2980:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:2980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:2980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:2980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:2980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:2980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:2980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:2980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:2980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:2980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:2980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:2980:EDES NPP MS")
  field(INPB, "QUAD:UNDS:2980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:3080:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:3080:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:3080:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:3080:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:3080:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:3080:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:3080:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:3080:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:3080:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:3080:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:3080:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:3080:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:3080:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:3080:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:3080:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:3080:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:3080:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:3080:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:3080:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:3080:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:3080:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:3080:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:3080:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:3080:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:3080:BMAX")
  field(DOL2, "QUAD:UNDS:3080:BMAX")
  field(DOL3, "QUAD:UNDS:3080:BMAX")
  field(DOL4, "QUAD:UNDS:3080:BMIN")
  field(DOL5, "QUAD:UNDS:3080:BMIN")
  field(DOL6, "QUAD:UNDS:3080:BMIN")
  field(LNK1, "QUAD:UNDS:3080:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:3080:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:3080:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:3080:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:3080:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:3080:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3080:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3080:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:3080:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:3080:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:3080:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3080:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3080:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3080:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3080:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3080:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:3080:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:3080:EDES NPP MS")
  field(INPB, "QUAD:UNDS:3080:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:3180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:3180:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:3180:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:3180:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:3180:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:3180:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:3180:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:3180:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:3180:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:3180:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:3180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:3180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:3180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:3180:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:3180:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:3180:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:3180:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:3180:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:3180:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:3180:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:3180:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:3180:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:3180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:3180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:3180:BMAX")
  field(DOL2, "QUAD:UNDS:3180:BMAX")
  field(DOL3, "QUAD:UNDS:3180:BMAX")
  field(DOL4, "QUAD:UNDS:3180:BMIN")
  field(DOL5, "QUAD:UNDS:3180:BMIN")
  field(DOL6, "QUAD:UNDS:3180:BMIN")
  field(LNK1, "QUAD:UNDS:3180:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:3180:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:3180:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:3180:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:3180:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:3180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:3180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:3180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:3180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:3180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:3180:EDES NPP MS")
  field(INPB, "QUAD:UNDS:3180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:3280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:3280:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:3280:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:3280:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:3280:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:3280:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:3280:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:3280:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:3280:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:3280:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:3280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:3280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:3280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:3280:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:3280:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:3280:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:3280:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:3280:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:3280:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:3280:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:3280:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:3280:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:3280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:3280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:3280:BMAX")
  field(DOL2, "QUAD:UNDS:3280:BMAX")
  field(DOL3, "QUAD:UNDS:3280:BMAX")
  field(DOL4, "QUAD:UNDS:3280:BMIN")
  field(DOL5, "QUAD:UNDS:3280:BMIN")
  field(DOL6, "QUAD:UNDS:3280:BMIN")
  field(LNK1, "QUAD:UNDS:3280:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:3280:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:3280:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:3280:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:3280:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:3280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:3280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:3280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:3280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:3280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:3280:EDES NPP MS")
  field(INPB, "QUAD:UNDS:3280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:3380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:3380:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:3380:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:3380:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:3380:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:3380:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:3380:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:3380:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:3380:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:3380:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:3380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:3380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:3380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:3380:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:3380:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:3380:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:3380:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:3380:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:3380:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:3380:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:3380:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:3380:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:3380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:3380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:3380:BMAX")
  field(DOL2, "QUAD:UNDS:3380:BMAX")
  field(DOL3, "QUAD:UNDS:3380:BMAX")
  field(DOL4, "QUAD:UNDS:3380:BMIN")
  field(DOL5, "QUAD:UNDS:3380:BMIN")
  field(DOL6, "QUAD:UNDS:3380:BMIN")
  field(LNK1, "QUAD:UNDS:3380:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:3380:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:3380:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:3380:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:3380:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:3380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:3380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:3380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:3380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:3380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:3380:EDES NPP MS")
  field(INPB, "QUAD:UNDS:3380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:3480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:3480:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:3480:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:3480:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:3480:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:3480:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:3480:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:3480:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:3480:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:3480:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:3480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:3480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:3480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:3480:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:3480:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:3480:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:3480:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:3480:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:3480:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:3480:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:3480:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:3480:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:3480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:3480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:3480:BMAX")
  field(DOL2, "QUAD:UNDS:3480:BMAX")
  field(DOL3, "QUAD:UNDS:3480:BMAX")
  field(DOL4, "QUAD:UNDS:3480:BMIN")
  field(DOL5, "QUAD:UNDS:3480:BMIN")
  field(DOL6, "QUAD:UNDS:3480:BMIN")
  field(LNK1, "QUAD:UNDS:3480:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:3480:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:3480:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:3480:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:3480:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:3480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:3480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:3480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:3480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:3480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:3480:EDES NPP MS")
  field(INPB, "QUAD:UNDS:3480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:3580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:3580:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:3580:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:3580:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:3580:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:3580:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:3580:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:3580:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:3580:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:3580:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:3580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:3580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:3580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:3580:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:3580:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:3580:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:3580:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:3580:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:3580:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:3580:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:3580:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:3580:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:3580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:3580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:3580:BMAX")
  field(DOL2, "QUAD:UNDS:3580:BMAX")
  field(DOL3, "QUAD:UNDS:3580:BMAX")
  field(DOL4, "QUAD:UNDS:3580:BMIN")
  field(DOL5, "QUAD:UNDS:3580:BMIN")
  field(DOL6, "QUAD:UNDS:3580:BMIN")
  field(LNK1, "QUAD:UNDS:3580:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:3580:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:3580:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:3580:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:3580:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:3580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:3580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:3580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:3580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:3580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:3580:EDES NPP MS")
  field(INPB, "QUAD:UNDS:3580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:3680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:3680:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:3680:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:3680:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:3680:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:3680:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:3680:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:3680:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:3680:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:3680:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:3680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:3680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:3680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:3680:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:3680:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:3680:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:3680:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:3680:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:3680:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:3680:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:3680:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:3680:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:3680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:3680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:3680:BMAX")
  field(DOL2, "QUAD:UNDS:3680:BMAX")
  field(DOL3, "QUAD:UNDS:3680:BMAX")
  field(DOL4, "QUAD:UNDS:3680:BMIN")
  field(DOL5, "QUAD:UNDS:3680:BMIN")
  field(DOL6, "QUAD:UNDS:3680:BMIN")
  field(LNK1, "QUAD:UNDS:3680:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:3680:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:3680:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:3680:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:3680:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:3680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:3680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:3680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:3680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:3680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:3680:EDES NPP MS")
  field(INPB, "QUAD:UNDS:3680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:3780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:3780:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:3780:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:3780:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:3780:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:3780:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:3780:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:3780:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:3780:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:3780:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:3780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:3780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:3780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:3780:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:3780:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:3780:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:3780:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:3780:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:3780:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:3780:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:3780:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:3780:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:3780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:3780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:3780:BMAX")
  field(DOL2, "QUAD:UNDS:3780:BMAX")
  field(DOL3, "QUAD:UNDS:3780:BMAX")
  field(DOL4, "QUAD:UNDS:3780:BMIN")
  field(DOL5, "QUAD:UNDS:3780:BMIN")
  field(DOL6, "QUAD:UNDS:3780:BMIN")
  field(LNK1, "QUAD:UNDS:3780:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:3780:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:3780:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:3780:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:3780:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:3780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:3780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:3780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:3780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:3780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:3780:EDES NPP MS")
  field(INPB, "QUAD:UNDS:3780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:3880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:3880:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:3880:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:3880:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:3880:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:3880:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:3880:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:3880:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:3880:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:3880:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:3880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:3880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:3880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:3880:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:3880:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:3880:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:3880:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:3880:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:3880:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:3880:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:3880:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:3880:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:3880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:3880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:3880:BMAX")
  field(DOL2, "QUAD:UNDS:3880:BMAX")
  field(DOL3, "QUAD:UNDS:3880:BMAX")
  field(DOL4, "QUAD:UNDS:3880:BMIN")
  field(DOL5, "QUAD:UNDS:3880:BMIN")
  field(DOL6, "QUAD:UNDS:3880:BMIN")
  field(LNK1, "QUAD:UNDS:3880:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:3880:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:3880:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:3880:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:3880:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:3880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:3880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:3880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:3880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:3880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:3880:EDES NPP MS")
  field(INPB, "QUAD:UNDS:3880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:3980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:3980:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:3980:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:3980:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:3980:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:3980:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:3980:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:3980:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:3980:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:3980:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:3980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:3980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:3980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:3980:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:3980:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:3980:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:3980:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:3980:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:3980:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:3980:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:3980:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:3980:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:3980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:3980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:3980:BMAX")
  field(DOL2, "QUAD:UNDS:3980:BMAX")
  field(DOL3, "QUAD:UNDS:3980:BMAX")
  field(DOL4, "QUAD:UNDS:3980:BMIN")
  field(DOL5, "QUAD:UNDS:3980:BMIN")
  field(DOL6, "QUAD:UNDS:3980:BMIN")
  field(LNK1, "QUAD:UNDS:3980:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:3980:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:3980:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:3980:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:3980:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:3980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:3980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:3980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:3980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:3980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:3980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:3980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:3980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:3980:EDES NPP MS")
  field(INPB, "QUAD:UNDS:3980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:4080:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:4080:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:4080:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:4080:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:4080:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:4080:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:4080:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:4080:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:4080:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:4080:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:4080:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:4080:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:4080:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:4080:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:4080:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:4080:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:4080:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:4080:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:4080:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:4080:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:4080:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:4080:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:4080:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:4080:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:4080:BMAX")
  field(DOL2, "QUAD:UNDS:4080:BMAX")
  field(DOL3, "QUAD:UNDS:4080:BMAX")
  field(DOL4, "QUAD:UNDS:4080:BMIN")
  field(DOL5, "QUAD:UNDS:4080:BMIN")
  field(DOL6, "QUAD:UNDS:4080:BMIN")
  field(LNK1, "QUAD:UNDS:4080:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:4080:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:4080:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:4080:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:4080:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:4080:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4080:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4080:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:4080:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:4080:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:4080:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4080:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4080:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4080:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4080:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4080:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:4080:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:4080:EDES NPP MS")
  field(INPB, "QUAD:UNDS:4080:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:4180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:4180:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:4180:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:4180:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:4180:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:4180:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:4180:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:4180:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:4180:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:4180:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:4180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:4180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:4180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:4180:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:4180:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:4180:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:4180:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:4180:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:4180:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:4180:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:4180:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:4180:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:4180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:4180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:4180:BMAX")
  field(DOL2, "QUAD:UNDS:4180:BMAX")
  field(DOL3, "QUAD:UNDS:4180:BMAX")
  field(DOL4, "QUAD:UNDS:4180:BMIN")
  field(DOL5, "QUAD:UNDS:4180:BMIN")
  field(DOL6, "QUAD:UNDS:4180:BMIN")
  field(LNK1, "QUAD:UNDS:4180:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:4180:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:4180:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:4180:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:4180:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:4180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:4180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:4180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:4180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:4180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:4180:EDES NPP MS")
  field(INPB, "QUAD:UNDS:4180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:4280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:4280:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:4280:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:4280:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:4280:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:4280:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:4280:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:4280:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:4280:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:4280:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:4280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:4280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:4280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:4280:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:4280:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:4280:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:4280:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:4280:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:4280:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:4280:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:4280:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:4280:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:4280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:4280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:4280:BMAX")
  field(DOL2, "QUAD:UNDS:4280:BMAX")
  field(DOL3, "QUAD:UNDS:4280:BMAX")
  field(DOL4, "QUAD:UNDS:4280:BMIN")
  field(DOL5, "QUAD:UNDS:4280:BMIN")
  field(DOL6, "QUAD:UNDS:4280:BMIN")
  field(LNK1, "QUAD:UNDS:4280:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:4280:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:4280:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:4280:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:4280:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:4280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:4280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:4280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:4280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:4280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:4280:EDES NPP MS")
  field(INPB, "QUAD:UNDS:4280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:4380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:4380:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:4380:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:4380:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:4380:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:4380:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:4380:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:4380:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:4380:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:4380:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:4380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:4380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:4380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:4380:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:4380:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:4380:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:4380:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:4380:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:4380:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:4380:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:4380:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:4380:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:4380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:4380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:4380:BMAX")
  field(DOL2, "QUAD:UNDS:4380:BMAX")
  field(DOL3, "QUAD:UNDS:4380:BMAX")
  field(DOL4, "QUAD:UNDS:4380:BMIN")
  field(DOL5, "QUAD:UNDS:4380:BMIN")
  field(DOL6, "QUAD:UNDS:4380:BMIN")
  field(LNK1, "QUAD:UNDS:4380:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:4380:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:4380:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:4380:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:4380:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:4380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:4380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:4380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:4380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:4380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:4380:EDES NPP MS")
  field(INPB, "QUAD:UNDS:4380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:4480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:4480:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:4480:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:4480:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:4480:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:4480:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:4480:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:4480:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:4480:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:4480:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:4480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:4480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:4480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:4480:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:4480:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:4480:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:4480:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:4480:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:4480:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:4480:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:4480:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:4480:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:4480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:4480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:4480:BMAX")
  field(DOL2, "QUAD:UNDS:4480:BMAX")
  field(DOL3, "QUAD:UNDS:4480:BMAX")
  field(DOL4, "QUAD:UNDS:4480:BMIN")
  field(DOL5, "QUAD:UNDS:4480:BMIN")
  field(DOL6, "QUAD:UNDS:4480:BMIN")
  field(LNK1, "QUAD:UNDS:4480:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:4480:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:4480:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:4480:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:4480:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:4480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:4480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:4480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:4480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:4480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:4480:EDES NPP MS")
  field(INPB, "QUAD:UNDS:4480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:4580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:4580:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:4580:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:4580:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:4580:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:4580:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:4580:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:4580:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:4580:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:4580:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:4580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:4580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:4580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:4580:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:4580:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:4580:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:4580:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:4580:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:4580:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:4580:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:4580:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:4580:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:4580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:4580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:4580:BMAX")
  field(DOL2, "QUAD:UNDS:4580:BMAX")
  field(DOL3, "QUAD:UNDS:4580:BMAX")
  field(DOL4, "QUAD:UNDS:4580:BMIN")
  field(DOL5, "QUAD:UNDS:4580:BMIN")
  field(DOL6, "QUAD:UNDS:4580:BMIN")
  field(LNK1, "QUAD:UNDS:4580:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:4580:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:4580:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:4580:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:4580:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:4580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:4580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:4580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:4580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:4580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:4580:EDES NPP MS")
  field(INPB, "QUAD:UNDS:4580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:4680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:4680:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:4680:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:4680:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:4680:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:4680:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:4680:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:4680:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:4680:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:4680:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:4680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:4680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:4680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:4680:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:4680:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:4680:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:4680:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:4680:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:4680:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:4680:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:4680:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:4680:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:4680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:4680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:4680:BMAX")
  field(DOL2, "QUAD:UNDS:4680:BMAX")
  field(DOL3, "QUAD:UNDS:4680:BMAX")
  field(DOL4, "QUAD:UNDS:4680:BMIN")
  field(DOL5, "QUAD:UNDS:4680:BMIN")
  field(DOL6, "QUAD:UNDS:4680:BMIN")
  field(LNK1, "QUAD:UNDS:4680:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:4680:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:4680:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:4680:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:4680:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:4680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:4680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:4680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:4680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:4680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:4680:EDES NPP MS")
  field(INPB, "QUAD:UNDS:4680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:UNDS:4780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "QUAD:UNDS:4780:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:UNDS:4780:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:UNDS:4780:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:UNDS:4780:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:UNDS:4780:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:UNDS:4780:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:UNDS:4780:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:UNDS:4780:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:UNDS:4780:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:UNDS:4780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:UNDS:4780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:UNDS:4780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:UNDS:4780:EDES.PROC PP")
    field(LNK2, "QUAD:UNDS:4780:EACT.PROC PP")
    field(LNK3, "QUAD:UNDS:4780:EERR.DISA PP")
    field(LNK4, "QUAD:UNDS:4780:ECON.PROC PP")
    field(LNK5, "QUAD:UNDS:4780:BMAGX.PROC PP")
    field(LNK6, "QUAD:UNDS:4780:BMAGY.PROC PP")
    field(LNK7, "QUAD:UNDS:4780:BLEM.PROC PP")
    field(LNK8, "QUAD:UNDS:4780:BMOD.PROC PP")
    field(LNK9, "QUAD:UNDS:4780:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:UNDS:4780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:UNDS:4780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:UNDS:4780:BMAX")
  field(DOL2, "QUAD:UNDS:4780:BMAX")
  field(DOL3, "QUAD:UNDS:4780:BMAX")
  field(DOL4, "QUAD:UNDS:4780:BMIN")
  field(DOL5, "QUAD:UNDS:4780:BMIN")
  field(DOL6, "QUAD:UNDS:4780:BMIN")
  field(LNK1, "QUAD:UNDS:4780:BMAGX.HOPR")
  field(LNK2, "QUAD:UNDS:4780:BMAGY.HOPR")
  field(LNK3, "QUAD:UNDS:4780:BLEM.HOPR")
  field(LNK4, "QUAD:UNDS:4780:BMAGX.LOPR PP")
  field(LNK5, "QUAD:UNDS:4780:BMAGY.LOPR PP")
  field(LNK6, "QUAD:UNDS:4780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:UNDS:4780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:UNDS:4780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:UNDS:4780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:UNDS:4780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:UNDS:4780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:UNDS:4780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:UNDS:4780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:UNDS:4780:EDES NPP MS")
  field(INPB, "QUAD:UNDS:4780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:1680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:1680:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:1680:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:1680:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:1680:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:1680:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:1680:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:1680:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:1680:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:1680:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:1680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:1680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:1680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:1680:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:1680:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:1680:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:1680:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:1680:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:1680:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:1680:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:1680:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:1680:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:1680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:1680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:1680:BMAX")
  field(DOL2, "XCOR:UNDS:1680:BMAX")
  field(DOL3, "XCOR:UNDS:1680:BMAX")
  field(DOL4, "XCOR:UNDS:1680:BMIN")
  field(DOL5, "XCOR:UNDS:1680:BMIN")
  field(DOL6, "XCOR:UNDS:1680:BMIN")
  field(LNK1, "XCOR:UNDS:1680:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:1680:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:1680:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:1680:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:1680:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:1680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:1680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:1680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:1680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:1680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:1680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:1680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:1680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:1680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:1680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:1680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:1680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:1680:EDES NPP MS")
  field(INPB, "XCOR:UNDS:1680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:1980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:1980:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:1980:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:1980:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:1980:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:1980:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:1980:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:1980:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:1980:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:1980:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:1980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:1980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:1980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:1980:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:1980:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:1980:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:1980:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:1980:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:1980:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:1980:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:1980:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:1980:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:1980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:1980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:1980:BMAX")
  field(DOL2, "XCOR:UNDS:1980:BMAX")
  field(DOL3, "XCOR:UNDS:1980:BMAX")
  field(DOL4, "XCOR:UNDS:1980:BMIN")
  field(DOL5, "XCOR:UNDS:1980:BMIN")
  field(DOL6, "XCOR:UNDS:1980:BMIN")
  field(LNK1, "XCOR:UNDS:1980:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:1980:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:1980:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:1980:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:1980:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:1980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:1980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:1980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:1980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:1980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:1980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:1980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:1980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:1980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:1980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:1980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:1980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:1980:EDES NPP MS")
  field(INPB, "XCOR:UNDS:1980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:2180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:2180:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:2180:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:2180:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:2180:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:2180:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:2180:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:2180:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:2180:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:2180:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:2180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:2180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:2180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:2180:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:2180:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:2180:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:2180:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:2180:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:2180:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:2180:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:2180:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:2180:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:2180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:2180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:2180:BMAX")
  field(DOL2, "XCOR:UNDS:2180:BMAX")
  field(DOL3, "XCOR:UNDS:2180:BMAX")
  field(DOL4, "XCOR:UNDS:2180:BMIN")
  field(DOL5, "XCOR:UNDS:2180:BMIN")
  field(DOL6, "XCOR:UNDS:2180:BMIN")
  field(LNK1, "XCOR:UNDS:2180:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:2180:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:2180:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:2180:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:2180:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:2180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:2180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:2180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:2180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:2180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:2180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:2180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:2180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:2180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:2180:EDES NPP MS")
  field(INPB, "XCOR:UNDS:2180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:2480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:2480:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:2480:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:2480:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:2480:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:2480:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:2480:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:2480:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:2480:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:2480:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:2480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:2480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:2480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:2480:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:2480:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:2480:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:2480:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:2480:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:2480:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:2480:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:2480:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:2480:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:2480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:2480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:2480:BMAX")
  field(DOL2, "XCOR:UNDS:2480:BMAX")
  field(DOL3, "XCOR:UNDS:2480:BMAX")
  field(DOL4, "XCOR:UNDS:2480:BMIN")
  field(DOL5, "XCOR:UNDS:2480:BMIN")
  field(DOL6, "XCOR:UNDS:2480:BMIN")
  field(LNK1, "XCOR:UNDS:2480:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:2480:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:2480:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:2480:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:2480:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:2480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:2480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:2480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:2480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:2480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:2480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:2480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:2480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:2480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:2480:EDES NPP MS")
  field(INPB, "XCOR:UNDS:2480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:2680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:2680:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:2680:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:2680:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:2680:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:2680:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:2680:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:2680:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:2680:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:2680:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:2680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:2680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:2680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:2680:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:2680:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:2680:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:2680:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:2680:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:2680:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:2680:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:2680:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:2680:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:2680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:2680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:2680:BMAX")
  field(DOL2, "XCOR:UNDS:2680:BMAX")
  field(DOL3, "XCOR:UNDS:2680:BMAX")
  field(DOL4, "XCOR:UNDS:2680:BMIN")
  field(DOL5, "XCOR:UNDS:2680:BMIN")
  field(DOL6, "XCOR:UNDS:2680:BMIN")
  field(LNK1, "XCOR:UNDS:2680:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:2680:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:2680:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:2680:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:2680:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:2680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:2680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:2680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:2680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:2680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:2680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:2680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:2680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:2680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:2680:EDES NPP MS")
  field(INPB, "XCOR:UNDS:2680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:2780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:2780:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:2780:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:2780:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:2780:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:2780:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:2780:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:2780:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:2780:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:2780:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:2780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:2780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:2780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:2780:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:2780:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:2780:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:2780:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:2780:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:2780:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:2780:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:2780:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:2780:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:2780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:2780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:2780:BMAX")
  field(DOL2, "XCOR:UNDS:2780:BMAX")
  field(DOL3, "XCOR:UNDS:2780:BMAX")
  field(DOL4, "XCOR:UNDS:2780:BMIN")
  field(DOL5, "XCOR:UNDS:2780:BMIN")
  field(DOL6, "XCOR:UNDS:2780:BMIN")
  field(LNK1, "XCOR:UNDS:2780:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:2780:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:2780:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:2780:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:2780:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:2780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:2780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:2780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:2780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:2780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:2780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:2780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:2780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:2780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:2780:EDES NPP MS")
  field(INPB, "XCOR:UNDS:2780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:2880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:2880:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:2880:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:2880:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:2880:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:2880:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:2880:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:2880:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:2880:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:2880:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:2880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:2880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:2880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:2880:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:2880:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:2880:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:2880:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:2880:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:2880:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:2880:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:2880:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:2880:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:2880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:2880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:2880:BMAX")
  field(DOL2, "XCOR:UNDS:2880:BMAX")
  field(DOL3, "XCOR:UNDS:2880:BMAX")
  field(DOL4, "XCOR:UNDS:2880:BMIN")
  field(DOL5, "XCOR:UNDS:2880:BMIN")
  field(DOL6, "XCOR:UNDS:2880:BMIN")
  field(LNK1, "XCOR:UNDS:2880:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:2880:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:2880:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:2880:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:2880:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:2880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:2880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:2880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:2880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:2880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:2880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:2880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:2880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:2880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:2880:EDES NPP MS")
  field(INPB, "XCOR:UNDS:2880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:2980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:2980:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:2980:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:2980:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:2980:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:2980:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:2980:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:2980:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:2980:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:2980:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:2980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:2980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:2980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:2980:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:2980:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:2980:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:2980:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:2980:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:2980:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:2980:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:2980:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:2980:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:2980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:2980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:2980:BMAX")
  field(DOL2, "XCOR:UNDS:2980:BMAX")
  field(DOL3, "XCOR:UNDS:2980:BMAX")
  field(DOL4, "XCOR:UNDS:2980:BMIN")
  field(DOL5, "XCOR:UNDS:2980:BMIN")
  field(DOL6, "XCOR:UNDS:2980:BMIN")
  field(LNK1, "XCOR:UNDS:2980:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:2980:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:2980:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:2980:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:2980:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:2980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:2980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:2980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:2980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:2980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:2980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:2980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:2980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:2980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:2980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:2980:EDES NPP MS")
  field(INPB, "XCOR:UNDS:2980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:3080:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:3080:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:3080:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:3080:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:3080:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:3080:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:3080:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:3080:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:3080:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:3080:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:3080:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:3080:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:3080:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:3080:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:3080:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:3080:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:3080:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:3080:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:3080:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:3080:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:3080:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:3080:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:3080:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:3080:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:3080:BMAX")
  field(DOL2, "XCOR:UNDS:3080:BMAX")
  field(DOL3, "XCOR:UNDS:3080:BMAX")
  field(DOL4, "XCOR:UNDS:3080:BMIN")
  field(DOL5, "XCOR:UNDS:3080:BMIN")
  field(DOL6, "XCOR:UNDS:3080:BMIN")
  field(LNK1, "XCOR:UNDS:3080:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:3080:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:3080:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:3080:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:3080:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:3080:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3080:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3080:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:3080:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:3080:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:3080:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3080:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3080:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3080:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3080:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3080:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:3080:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:3080:EDES NPP MS")
  field(INPB, "XCOR:UNDS:3080:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:3180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:3180:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:3180:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:3180:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:3180:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:3180:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:3180:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:3180:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:3180:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:3180:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:3180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:3180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:3180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:3180:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:3180:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:3180:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:3180:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:3180:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:3180:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:3180:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:3180:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:3180:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:3180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:3180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:3180:BMAX")
  field(DOL2, "XCOR:UNDS:3180:BMAX")
  field(DOL3, "XCOR:UNDS:3180:BMAX")
  field(DOL4, "XCOR:UNDS:3180:BMIN")
  field(DOL5, "XCOR:UNDS:3180:BMIN")
  field(DOL6, "XCOR:UNDS:3180:BMIN")
  field(LNK1, "XCOR:UNDS:3180:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:3180:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:3180:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:3180:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:3180:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:3180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:3180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:3180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:3180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:3180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:3180:EDES NPP MS")
  field(INPB, "XCOR:UNDS:3180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:3280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:3280:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:3280:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:3280:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:3280:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:3280:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:3280:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:3280:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:3280:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:3280:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:3280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:3280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:3280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:3280:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:3280:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:3280:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:3280:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:3280:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:3280:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:3280:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:3280:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:3280:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:3280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:3280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:3280:BMAX")
  field(DOL2, "XCOR:UNDS:3280:BMAX")
  field(DOL3, "XCOR:UNDS:3280:BMAX")
  field(DOL4, "XCOR:UNDS:3280:BMIN")
  field(DOL5, "XCOR:UNDS:3280:BMIN")
  field(DOL6, "XCOR:UNDS:3280:BMIN")
  field(LNK1, "XCOR:UNDS:3280:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:3280:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:3280:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:3280:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:3280:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:3280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:3280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:3280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:3280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:3280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:3280:EDES NPP MS")
  field(INPB, "XCOR:UNDS:3280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:3380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:3380:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:3380:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:3380:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:3380:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:3380:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:3380:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:3380:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:3380:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:3380:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:3380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:3380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:3380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:3380:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:3380:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:3380:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:3380:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:3380:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:3380:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:3380:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:3380:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:3380:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:3380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:3380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:3380:BMAX")
  field(DOL2, "XCOR:UNDS:3380:BMAX")
  field(DOL3, "XCOR:UNDS:3380:BMAX")
  field(DOL4, "XCOR:UNDS:3380:BMIN")
  field(DOL5, "XCOR:UNDS:3380:BMIN")
  field(DOL6, "XCOR:UNDS:3380:BMIN")
  field(LNK1, "XCOR:UNDS:3380:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:3380:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:3380:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:3380:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:3380:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:3380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:3380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:3380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:3380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:3380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:3380:EDES NPP MS")
  field(INPB, "XCOR:UNDS:3380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:3480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:3480:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:3480:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:3480:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:3480:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:3480:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:3480:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:3480:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:3480:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:3480:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:3480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:3480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:3480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:3480:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:3480:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:3480:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:3480:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:3480:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:3480:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:3480:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:3480:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:3480:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:3480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:3480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:3480:BMAX")
  field(DOL2, "XCOR:UNDS:3480:BMAX")
  field(DOL3, "XCOR:UNDS:3480:BMAX")
  field(DOL4, "XCOR:UNDS:3480:BMIN")
  field(DOL5, "XCOR:UNDS:3480:BMIN")
  field(DOL6, "XCOR:UNDS:3480:BMIN")
  field(LNK1, "XCOR:UNDS:3480:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:3480:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:3480:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:3480:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:3480:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:3480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:3480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:3480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:3480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:3480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:3480:EDES NPP MS")
  field(INPB, "XCOR:UNDS:3480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:3580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:3580:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:3580:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:3580:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:3580:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:3580:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:3580:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:3580:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:3580:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:3580:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:3580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:3580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:3580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:3580:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:3580:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:3580:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:3580:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:3580:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:3580:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:3580:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:3580:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:3580:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:3580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:3580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:3580:BMAX")
  field(DOL2, "XCOR:UNDS:3580:BMAX")
  field(DOL3, "XCOR:UNDS:3580:BMAX")
  field(DOL4, "XCOR:UNDS:3580:BMIN")
  field(DOL5, "XCOR:UNDS:3580:BMIN")
  field(DOL6, "XCOR:UNDS:3580:BMIN")
  field(LNK1, "XCOR:UNDS:3580:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:3580:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:3580:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:3580:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:3580:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:3580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:3580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:3580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:3580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:3580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:3580:EDES NPP MS")
  field(INPB, "XCOR:UNDS:3580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:3680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:3680:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:3680:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:3680:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:3680:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:3680:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:3680:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:3680:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:3680:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:3680:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:3680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:3680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:3680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:3680:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:3680:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:3680:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:3680:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:3680:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:3680:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:3680:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:3680:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:3680:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:3680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:3680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:3680:BMAX")
  field(DOL2, "XCOR:UNDS:3680:BMAX")
  field(DOL3, "XCOR:UNDS:3680:BMAX")
  field(DOL4, "XCOR:UNDS:3680:BMIN")
  field(DOL5, "XCOR:UNDS:3680:BMIN")
  field(DOL6, "XCOR:UNDS:3680:BMIN")
  field(LNK1, "XCOR:UNDS:3680:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:3680:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:3680:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:3680:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:3680:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:3680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:3680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:3680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:3680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:3680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:3680:EDES NPP MS")
  field(INPB, "XCOR:UNDS:3680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:3780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:3780:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:3780:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:3780:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:3780:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:3780:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:3780:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:3780:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:3780:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:3780:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:3780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:3780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:3780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:3780:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:3780:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:3780:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:3780:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:3780:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:3780:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:3780:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:3780:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:3780:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:3780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:3780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:3780:BMAX")
  field(DOL2, "XCOR:UNDS:3780:BMAX")
  field(DOL3, "XCOR:UNDS:3780:BMAX")
  field(DOL4, "XCOR:UNDS:3780:BMIN")
  field(DOL5, "XCOR:UNDS:3780:BMIN")
  field(DOL6, "XCOR:UNDS:3780:BMIN")
  field(LNK1, "XCOR:UNDS:3780:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:3780:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:3780:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:3780:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:3780:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:3780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:3780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:3780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:3780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:3780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:3780:EDES NPP MS")
  field(INPB, "XCOR:UNDS:3780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:3880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:3880:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:3880:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:3880:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:3880:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:3880:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:3880:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:3880:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:3880:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:3880:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:3880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:3880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:3880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:3880:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:3880:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:3880:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:3880:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:3880:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:3880:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:3880:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:3880:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:3880:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:3880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:3880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:3880:BMAX")
  field(DOL2, "XCOR:UNDS:3880:BMAX")
  field(DOL3, "XCOR:UNDS:3880:BMAX")
  field(DOL4, "XCOR:UNDS:3880:BMIN")
  field(DOL5, "XCOR:UNDS:3880:BMIN")
  field(DOL6, "XCOR:UNDS:3880:BMIN")
  field(LNK1, "XCOR:UNDS:3880:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:3880:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:3880:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:3880:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:3880:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:3880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:3880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:3880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:3880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:3880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:3880:EDES NPP MS")
  field(INPB, "XCOR:UNDS:3880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:3980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:3980:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:3980:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:3980:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:3980:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:3980:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:3980:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:3980:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:3980:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:3980:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:3980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:3980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:3980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:3980:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:3980:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:3980:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:3980:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:3980:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:3980:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:3980:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:3980:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:3980:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:3980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:3980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:3980:BMAX")
  field(DOL2, "XCOR:UNDS:3980:BMAX")
  field(DOL3, "XCOR:UNDS:3980:BMAX")
  field(DOL4, "XCOR:UNDS:3980:BMIN")
  field(DOL5, "XCOR:UNDS:3980:BMIN")
  field(DOL6, "XCOR:UNDS:3980:BMIN")
  field(LNK1, "XCOR:UNDS:3980:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:3980:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:3980:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:3980:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:3980:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:3980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:3980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:3980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:3980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:3980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:3980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:3980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:3980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:3980:EDES NPP MS")
  field(INPB, "XCOR:UNDS:3980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:4080:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:4080:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:4080:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:4080:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:4080:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:4080:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:4080:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:4080:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:4080:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:4080:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:4080:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:4080:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:4080:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:4080:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:4080:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:4080:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:4080:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:4080:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:4080:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:4080:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:4080:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:4080:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:4080:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:4080:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:4080:BMAX")
  field(DOL2, "XCOR:UNDS:4080:BMAX")
  field(DOL3, "XCOR:UNDS:4080:BMAX")
  field(DOL4, "XCOR:UNDS:4080:BMIN")
  field(DOL5, "XCOR:UNDS:4080:BMIN")
  field(DOL6, "XCOR:UNDS:4080:BMIN")
  field(LNK1, "XCOR:UNDS:4080:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:4080:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:4080:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:4080:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:4080:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:4080:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4080:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4080:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:4080:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:4080:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:4080:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4080:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4080:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4080:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4080:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4080:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:4080:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:4080:EDES NPP MS")
  field(INPB, "XCOR:UNDS:4080:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:4180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:4180:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:4180:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:4180:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:4180:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:4180:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:4180:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:4180:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:4180:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:4180:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:4180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:4180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:4180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:4180:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:4180:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:4180:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:4180:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:4180:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:4180:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:4180:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:4180:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:4180:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:4180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:4180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:4180:BMAX")
  field(DOL2, "XCOR:UNDS:4180:BMAX")
  field(DOL3, "XCOR:UNDS:4180:BMAX")
  field(DOL4, "XCOR:UNDS:4180:BMIN")
  field(DOL5, "XCOR:UNDS:4180:BMIN")
  field(DOL6, "XCOR:UNDS:4180:BMIN")
  field(LNK1, "XCOR:UNDS:4180:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:4180:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:4180:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:4180:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:4180:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:4180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:4180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:4180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:4180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:4180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:4180:EDES NPP MS")
  field(INPB, "XCOR:UNDS:4180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:4280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:4280:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:4280:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:4280:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:4280:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:4280:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:4280:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:4280:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:4280:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:4280:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:4280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:4280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:4280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:4280:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:4280:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:4280:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:4280:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:4280:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:4280:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:4280:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:4280:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:4280:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:4280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:4280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:4280:BMAX")
  field(DOL2, "XCOR:UNDS:4280:BMAX")
  field(DOL3, "XCOR:UNDS:4280:BMAX")
  field(DOL4, "XCOR:UNDS:4280:BMIN")
  field(DOL5, "XCOR:UNDS:4280:BMIN")
  field(DOL6, "XCOR:UNDS:4280:BMIN")
  field(LNK1, "XCOR:UNDS:4280:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:4280:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:4280:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:4280:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:4280:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:4280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:4280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:4280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:4280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:4280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:4280:EDES NPP MS")
  field(INPB, "XCOR:UNDS:4280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:4380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:4380:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:4380:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:4380:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:4380:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:4380:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:4380:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:4380:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:4380:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:4380:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:4380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:4380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:4380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:4380:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:4380:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:4380:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:4380:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:4380:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:4380:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:4380:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:4380:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:4380:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:4380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:4380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:4380:BMAX")
  field(DOL2, "XCOR:UNDS:4380:BMAX")
  field(DOL3, "XCOR:UNDS:4380:BMAX")
  field(DOL4, "XCOR:UNDS:4380:BMIN")
  field(DOL5, "XCOR:UNDS:4380:BMIN")
  field(DOL6, "XCOR:UNDS:4380:BMIN")
  field(LNK1, "XCOR:UNDS:4380:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:4380:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:4380:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:4380:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:4380:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:4380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:4380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:4380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:4380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:4380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:4380:EDES NPP MS")
  field(INPB, "XCOR:UNDS:4380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:4480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:4480:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:4480:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:4480:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:4480:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:4480:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:4480:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:4480:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:4480:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:4480:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:4480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:4480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:4480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:4480:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:4480:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:4480:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:4480:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:4480:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:4480:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:4480:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:4480:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:4480:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:4480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:4480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:4480:BMAX")
  field(DOL2, "XCOR:UNDS:4480:BMAX")
  field(DOL3, "XCOR:UNDS:4480:BMAX")
  field(DOL4, "XCOR:UNDS:4480:BMIN")
  field(DOL5, "XCOR:UNDS:4480:BMIN")
  field(DOL6, "XCOR:UNDS:4480:BMIN")
  field(LNK1, "XCOR:UNDS:4480:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:4480:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:4480:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:4480:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:4480:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:4480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:4480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:4480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:4480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:4480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:4480:EDES NPP MS")
  field(INPB, "XCOR:UNDS:4480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:4580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:4580:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:4580:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:4580:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:4580:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:4580:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:4580:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:4580:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:4580:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:4580:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:4580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:4580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:4580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:4580:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:4580:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:4580:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:4580:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:4580:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:4580:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:4580:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:4580:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:4580:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:4580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:4580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:4580:BMAX")
  field(DOL2, "XCOR:UNDS:4580:BMAX")
  field(DOL3, "XCOR:UNDS:4580:BMAX")
  field(DOL4, "XCOR:UNDS:4580:BMIN")
  field(DOL5, "XCOR:UNDS:4580:BMIN")
  field(DOL6, "XCOR:UNDS:4580:BMIN")
  field(LNK1, "XCOR:UNDS:4580:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:4580:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:4580:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:4580:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:4580:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:4580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:4580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:4580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:4580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:4580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:4580:EDES NPP MS")
  field(INPB, "XCOR:UNDS:4580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:4680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:4680:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:4680:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:4680:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:4680:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:4680:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:4680:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:4680:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:4680:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:4680:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:4680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:4680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:4680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:4680:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:4680:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:4680:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:4680:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:4680:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:4680:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:4680:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:4680:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:4680:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:4680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:4680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:4680:BMAX")
  field(DOL2, "XCOR:UNDS:4680:BMAX")
  field(DOL3, "XCOR:UNDS:4680:BMAX")
  field(DOL4, "XCOR:UNDS:4680:BMIN")
  field(DOL5, "XCOR:UNDS:4680:BMIN")
  field(DOL6, "XCOR:UNDS:4680:BMIN")
  field(LNK1, "XCOR:UNDS:4680:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:4680:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:4680:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:4680:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:4680:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:4680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:4680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:4680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:4680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:4680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:4680:EDES NPP MS")
  field(INPB, "XCOR:UNDS:4680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:4780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:4780:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:4780:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:4780:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:4780:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:4780:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:4780:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:4780:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:4780:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:4780:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:4780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:4780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:4780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:4780:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:4780:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:4780:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:4780:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:4780:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:4780:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:4780:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:4780:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:4780:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:4780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:4780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:4780:BMAX")
  field(DOL2, "XCOR:UNDS:4780:BMAX")
  field(DOL3, "XCOR:UNDS:4780:BMAX")
  field(DOL4, "XCOR:UNDS:4780:BMIN")
  field(DOL5, "XCOR:UNDS:4780:BMIN")
  field(DOL6, "XCOR:UNDS:4780:BMIN")
  field(LNK1, "XCOR:UNDS:4780:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:4780:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:4780:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:4780:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:4780:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:4780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:4780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:4780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:4780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:4780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:4780:EDES NPP MS")
  field(INPB, "XCOR:UNDS:4780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:4982:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:4982:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:4982:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:4982:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:4982:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:4982:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:4982:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:4982:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:4982:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:4982:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:4982:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:4982:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:4982:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:4982:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:4982:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:4982:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:4982:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:4982:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:4982:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:4982:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:4982:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:4982:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:4982:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:4982:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:4982:BMAX")
  field(DOL2, "XCOR:UNDS:4982:BMAX")
  field(DOL3, "XCOR:UNDS:4982:BMAX")
  field(DOL4, "XCOR:UNDS:4982:BMIN")
  field(DOL5, "XCOR:UNDS:4982:BMIN")
  field(DOL6, "XCOR:UNDS:4982:BMIN")
  field(LNK1, "XCOR:UNDS:4982:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:4982:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:4982:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:4982:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:4982:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:4982:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4982:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:4982:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:4982:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:4982:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:4982:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4982:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4982:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4982:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:4982:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:4982:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:4982:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:4982:EDES NPP MS")
  field(INPB, "XCOR:UNDS:4982:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:5038:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:5038:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:5038:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:5038:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:5038:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:5038:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:5038:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:5038:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:5038:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:5038:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:5038:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:5038:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:5038:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:5038:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:5038:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:5038:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:5038:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:5038:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:5038:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:5038:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:5038:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:5038:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:5038:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:5038:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:5038:BMAX")
  field(DOL2, "XCOR:UNDS:5038:BMAX")
  field(DOL3, "XCOR:UNDS:5038:BMAX")
  field(DOL4, "XCOR:UNDS:5038:BMIN")
  field(DOL5, "XCOR:UNDS:5038:BMIN")
  field(DOL6, "XCOR:UNDS:5038:BMIN")
  field(LNK1, "XCOR:UNDS:5038:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:5038:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:5038:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:5038:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:5038:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:5038:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:5038:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:5038:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:5038:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:5038:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:5038:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:5038:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:5038:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:5038:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:5038:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:UNDS:5038:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:5038:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:5038:EDES NPP MS")
  field(INPB, "XCOR:UNDS:5038:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:1680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:1680:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:1680:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:1680:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:1680:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:1680:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:1680:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:1680:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:1680:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:1680:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:1680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:1680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:1680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:1680:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:1680:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:1680:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:1680:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:1680:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:1680:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:1680:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:1680:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:1680:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:1680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:1680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:1680:BMAX")
  field(DOL2, "YCOR:UNDS:1680:BMAX")
  field(DOL3, "YCOR:UNDS:1680:BMAX")
  field(DOL4, "YCOR:UNDS:1680:BMIN")
  field(DOL5, "YCOR:UNDS:1680:BMIN")
  field(DOL6, "YCOR:UNDS:1680:BMIN")
  field(LNK1, "YCOR:UNDS:1680:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:1680:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:1680:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:1680:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:1680:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:1680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:1680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:1680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:1680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:1680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:1680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:1680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:1680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:1680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:1680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:1680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:1680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:1680:EDES NPP MS")
  field(INPB, "YCOR:UNDS:1680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:1980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:1980:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:1980:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:1980:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:1980:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:1980:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:1980:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:1980:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:1980:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:1980:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:1980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:1980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:1980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:1980:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:1980:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:1980:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:1980:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:1980:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:1980:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:1980:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:1980:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:1980:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:1980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:1980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:1980:BMAX")
  field(DOL2, "YCOR:UNDS:1980:BMAX")
  field(DOL3, "YCOR:UNDS:1980:BMAX")
  field(DOL4, "YCOR:UNDS:1980:BMIN")
  field(DOL5, "YCOR:UNDS:1980:BMIN")
  field(DOL6, "YCOR:UNDS:1980:BMIN")
  field(LNK1, "YCOR:UNDS:1980:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:1980:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:1980:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:1980:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:1980:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:1980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:1980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:1980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:1980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:1980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:1980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:1980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:1980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:1980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:1980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:1980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:1980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:1980:EDES NPP MS")
  field(INPB, "YCOR:UNDS:1980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:2180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:2180:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:2180:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:2180:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:2180:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:2180:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:2180:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:2180:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:2180:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:2180:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:2180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:2180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:2180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:2180:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:2180:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:2180:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:2180:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:2180:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:2180:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:2180:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:2180:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:2180:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:2180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:2180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:2180:BMAX")
  field(DOL2, "YCOR:UNDS:2180:BMAX")
  field(DOL3, "YCOR:UNDS:2180:BMAX")
  field(DOL4, "YCOR:UNDS:2180:BMIN")
  field(DOL5, "YCOR:UNDS:2180:BMIN")
  field(DOL6, "YCOR:UNDS:2180:BMIN")
  field(LNK1, "YCOR:UNDS:2180:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:2180:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:2180:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:2180:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:2180:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:2180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:2180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:2180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:2180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:2180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:2180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:2180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:2180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:2180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:2180:EDES NPP MS")
  field(INPB, "YCOR:UNDS:2180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:2480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:2480:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:2480:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:2480:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:2480:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:2480:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:2480:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:2480:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:2480:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:2480:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:2480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:2480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:2480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:2480:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:2480:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:2480:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:2480:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:2480:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:2480:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:2480:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:2480:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:2480:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:2480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:2480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:2480:BMAX")
  field(DOL2, "YCOR:UNDS:2480:BMAX")
  field(DOL3, "YCOR:UNDS:2480:BMAX")
  field(DOL4, "YCOR:UNDS:2480:BMIN")
  field(DOL5, "YCOR:UNDS:2480:BMIN")
  field(DOL6, "YCOR:UNDS:2480:BMIN")
  field(LNK1, "YCOR:UNDS:2480:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:2480:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:2480:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:2480:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:2480:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:2480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:2480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:2480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:2480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:2480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:2480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:2480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:2480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:2480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:2480:EDES NPP MS")
  field(INPB, "YCOR:UNDS:2480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:2680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:2680:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:2680:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:2680:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:2680:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:2680:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:2680:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:2680:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:2680:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:2680:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:2680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:2680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:2680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:2680:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:2680:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:2680:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:2680:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:2680:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:2680:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:2680:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:2680:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:2680:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:2680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:2680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:2680:BMAX")
  field(DOL2, "YCOR:UNDS:2680:BMAX")
  field(DOL3, "YCOR:UNDS:2680:BMAX")
  field(DOL4, "YCOR:UNDS:2680:BMIN")
  field(DOL5, "YCOR:UNDS:2680:BMIN")
  field(DOL6, "YCOR:UNDS:2680:BMIN")
  field(LNK1, "YCOR:UNDS:2680:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:2680:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:2680:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:2680:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:2680:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:2680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:2680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:2680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:2680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:2680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:2680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:2680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:2680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:2680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:2680:EDES NPP MS")
  field(INPB, "YCOR:UNDS:2680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:2780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:2780:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:2780:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:2780:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:2780:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:2780:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:2780:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:2780:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:2780:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:2780:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:2780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:2780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:2780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:2780:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:2780:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:2780:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:2780:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:2780:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:2780:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:2780:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:2780:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:2780:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:2780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:2780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:2780:BMAX")
  field(DOL2, "YCOR:UNDS:2780:BMAX")
  field(DOL3, "YCOR:UNDS:2780:BMAX")
  field(DOL4, "YCOR:UNDS:2780:BMIN")
  field(DOL5, "YCOR:UNDS:2780:BMIN")
  field(DOL6, "YCOR:UNDS:2780:BMIN")
  field(LNK1, "YCOR:UNDS:2780:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:2780:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:2780:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:2780:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:2780:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:2780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:2780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:2780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:2780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:2780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:2780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:2780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:2780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:2780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:2780:EDES NPP MS")
  field(INPB, "YCOR:UNDS:2780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:2880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:2880:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:2880:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:2880:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:2880:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:2880:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:2880:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:2880:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:2880:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:2880:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:2880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:2880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:2880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:2880:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:2880:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:2880:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:2880:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:2880:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:2880:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:2880:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:2880:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:2880:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:2880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:2880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:2880:BMAX")
  field(DOL2, "YCOR:UNDS:2880:BMAX")
  field(DOL3, "YCOR:UNDS:2880:BMAX")
  field(DOL4, "YCOR:UNDS:2880:BMIN")
  field(DOL5, "YCOR:UNDS:2880:BMIN")
  field(DOL6, "YCOR:UNDS:2880:BMIN")
  field(LNK1, "YCOR:UNDS:2880:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:2880:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:2880:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:2880:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:2880:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:2880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:2880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:2880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:2880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:2880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:2880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:2880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:2880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:2880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:2880:EDES NPP MS")
  field(INPB, "YCOR:UNDS:2880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:2980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:2980:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:2980:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:2980:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:2980:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:2980:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:2980:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:2980:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:2980:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:2980:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:2980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:2980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:2980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:2980:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:2980:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:2980:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:2980:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:2980:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:2980:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:2980:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:2980:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:2980:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:2980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:2980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:2980:BMAX")
  field(DOL2, "YCOR:UNDS:2980:BMAX")
  field(DOL3, "YCOR:UNDS:2980:BMAX")
  field(DOL4, "YCOR:UNDS:2980:BMIN")
  field(DOL5, "YCOR:UNDS:2980:BMIN")
  field(DOL6, "YCOR:UNDS:2980:BMIN")
  field(LNK1, "YCOR:UNDS:2980:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:2980:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:2980:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:2980:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:2980:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:2980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:2980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:2980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:2980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:2980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:2980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:2980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:2980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:2980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:2980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:2980:EDES NPP MS")
  field(INPB, "YCOR:UNDS:2980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:3080:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:3080:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:3080:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:3080:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:3080:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:3080:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:3080:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:3080:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:3080:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:3080:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:3080:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:3080:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:3080:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:3080:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:3080:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:3080:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:3080:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:3080:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:3080:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:3080:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:3080:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:3080:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:3080:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:3080:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:3080:BMAX")
  field(DOL2, "YCOR:UNDS:3080:BMAX")
  field(DOL3, "YCOR:UNDS:3080:BMAX")
  field(DOL4, "YCOR:UNDS:3080:BMIN")
  field(DOL5, "YCOR:UNDS:3080:BMIN")
  field(DOL6, "YCOR:UNDS:3080:BMIN")
  field(LNK1, "YCOR:UNDS:3080:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:3080:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:3080:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:3080:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:3080:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:3080:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3080:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3080:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:3080:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:3080:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:3080:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3080:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3080:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3080:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3080:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3080:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:3080:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:3080:EDES NPP MS")
  field(INPB, "YCOR:UNDS:3080:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:3180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:3180:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:3180:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:3180:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:3180:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:3180:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:3180:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:3180:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:3180:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:3180:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:3180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:3180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:3180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:3180:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:3180:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:3180:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:3180:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:3180:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:3180:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:3180:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:3180:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:3180:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:3180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:3180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:3180:BMAX")
  field(DOL2, "YCOR:UNDS:3180:BMAX")
  field(DOL3, "YCOR:UNDS:3180:BMAX")
  field(DOL4, "YCOR:UNDS:3180:BMIN")
  field(DOL5, "YCOR:UNDS:3180:BMIN")
  field(DOL6, "YCOR:UNDS:3180:BMIN")
  field(LNK1, "YCOR:UNDS:3180:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:3180:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:3180:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:3180:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:3180:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:3180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:3180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:3180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:3180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:3180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:3180:EDES NPP MS")
  field(INPB, "YCOR:UNDS:3180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:3280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:3280:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:3280:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:3280:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:3280:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:3280:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:3280:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:3280:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:3280:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:3280:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:3280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:3280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:3280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:3280:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:3280:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:3280:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:3280:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:3280:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:3280:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:3280:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:3280:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:3280:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:3280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:3280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:3280:BMAX")
  field(DOL2, "YCOR:UNDS:3280:BMAX")
  field(DOL3, "YCOR:UNDS:3280:BMAX")
  field(DOL4, "YCOR:UNDS:3280:BMIN")
  field(DOL5, "YCOR:UNDS:3280:BMIN")
  field(DOL6, "YCOR:UNDS:3280:BMIN")
  field(LNK1, "YCOR:UNDS:3280:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:3280:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:3280:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:3280:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:3280:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:3280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:3280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:3280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:3280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:3280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:3280:EDES NPP MS")
  field(INPB, "YCOR:UNDS:3280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:3380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:3380:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:3380:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:3380:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:3380:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:3380:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:3380:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:3380:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:3380:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:3380:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:3380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:3380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:3380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:3380:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:3380:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:3380:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:3380:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:3380:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:3380:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:3380:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:3380:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:3380:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:3380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:3380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:3380:BMAX")
  field(DOL2, "YCOR:UNDS:3380:BMAX")
  field(DOL3, "YCOR:UNDS:3380:BMAX")
  field(DOL4, "YCOR:UNDS:3380:BMIN")
  field(DOL5, "YCOR:UNDS:3380:BMIN")
  field(DOL6, "YCOR:UNDS:3380:BMIN")
  field(LNK1, "YCOR:UNDS:3380:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:3380:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:3380:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:3380:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:3380:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:3380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:3380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:3380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:3380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:3380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:3380:EDES NPP MS")
  field(INPB, "YCOR:UNDS:3380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:3480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:3480:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:3480:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:3480:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:3480:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:3480:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:3480:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:3480:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:3480:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:3480:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:3480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:3480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:3480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:3480:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:3480:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:3480:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:3480:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:3480:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:3480:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:3480:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:3480:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:3480:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:3480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:3480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:3480:BMAX")
  field(DOL2, "YCOR:UNDS:3480:BMAX")
  field(DOL3, "YCOR:UNDS:3480:BMAX")
  field(DOL4, "YCOR:UNDS:3480:BMIN")
  field(DOL5, "YCOR:UNDS:3480:BMIN")
  field(DOL6, "YCOR:UNDS:3480:BMIN")
  field(LNK1, "YCOR:UNDS:3480:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:3480:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:3480:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:3480:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:3480:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:3480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:3480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:3480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:3480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:3480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:3480:EDES NPP MS")
  field(INPB, "YCOR:UNDS:3480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:3580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:3580:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:3580:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:3580:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:3580:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:3580:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:3580:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:3580:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:3580:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:3580:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:3580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:3580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:3580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:3580:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:3580:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:3580:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:3580:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:3580:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:3580:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:3580:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:3580:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:3580:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:3580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:3580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:3580:BMAX")
  field(DOL2, "YCOR:UNDS:3580:BMAX")
  field(DOL3, "YCOR:UNDS:3580:BMAX")
  field(DOL4, "YCOR:UNDS:3580:BMIN")
  field(DOL5, "YCOR:UNDS:3580:BMIN")
  field(DOL6, "YCOR:UNDS:3580:BMIN")
  field(LNK1, "YCOR:UNDS:3580:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:3580:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:3580:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:3580:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:3580:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:3580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:3580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:3580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:3580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:3580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:3580:EDES NPP MS")
  field(INPB, "YCOR:UNDS:3580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:3680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:3680:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:3680:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:3680:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:3680:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:3680:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:3680:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:3680:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:3680:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:3680:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:3680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:3680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:3680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:3680:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:3680:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:3680:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:3680:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:3680:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:3680:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:3680:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:3680:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:3680:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:3680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:3680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:3680:BMAX")
  field(DOL2, "YCOR:UNDS:3680:BMAX")
  field(DOL3, "YCOR:UNDS:3680:BMAX")
  field(DOL4, "YCOR:UNDS:3680:BMIN")
  field(DOL5, "YCOR:UNDS:3680:BMIN")
  field(DOL6, "YCOR:UNDS:3680:BMIN")
  field(LNK1, "YCOR:UNDS:3680:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:3680:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:3680:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:3680:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:3680:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:3680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:3680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:3680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:3680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:3680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:3680:EDES NPP MS")
  field(INPB, "YCOR:UNDS:3680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:3780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:3780:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:3780:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:3780:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:3780:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:3780:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:3780:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:3780:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:3780:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:3780:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:3780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:3780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:3780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:3780:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:3780:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:3780:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:3780:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:3780:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:3780:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:3780:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:3780:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:3780:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:3780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:3780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:3780:BMAX")
  field(DOL2, "YCOR:UNDS:3780:BMAX")
  field(DOL3, "YCOR:UNDS:3780:BMAX")
  field(DOL4, "YCOR:UNDS:3780:BMIN")
  field(DOL5, "YCOR:UNDS:3780:BMIN")
  field(DOL6, "YCOR:UNDS:3780:BMIN")
  field(LNK1, "YCOR:UNDS:3780:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:3780:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:3780:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:3780:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:3780:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:3780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:3780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:3780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:3780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:3780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:3780:EDES NPP MS")
  field(INPB, "YCOR:UNDS:3780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:3880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:3880:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:3880:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:3880:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:3880:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:3880:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:3880:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:3880:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:3880:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:3880:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:3880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:3880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:3880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:3880:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:3880:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:3880:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:3880:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:3880:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:3880:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:3880:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:3880:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:3880:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:3880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:3880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:3880:BMAX")
  field(DOL2, "YCOR:UNDS:3880:BMAX")
  field(DOL3, "YCOR:UNDS:3880:BMAX")
  field(DOL4, "YCOR:UNDS:3880:BMIN")
  field(DOL5, "YCOR:UNDS:3880:BMIN")
  field(DOL6, "YCOR:UNDS:3880:BMIN")
  field(LNK1, "YCOR:UNDS:3880:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:3880:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:3880:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:3880:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:3880:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:3880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:3880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:3880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:3880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:3880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:3880:EDES NPP MS")
  field(INPB, "YCOR:UNDS:3880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:3980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:3980:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:3980:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:3980:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:3980:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:3980:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:3980:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:3980:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:3980:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:3980:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:3980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:3980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:3980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:3980:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:3980:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:3980:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:3980:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:3980:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:3980:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:3980:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:3980:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:3980:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:3980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:3980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:3980:BMAX")
  field(DOL2, "YCOR:UNDS:3980:BMAX")
  field(DOL3, "YCOR:UNDS:3980:BMAX")
  field(DOL4, "YCOR:UNDS:3980:BMIN")
  field(DOL5, "YCOR:UNDS:3980:BMIN")
  field(DOL6, "YCOR:UNDS:3980:BMIN")
  field(LNK1, "YCOR:UNDS:3980:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:3980:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:3980:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:3980:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:3980:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:3980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:3980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:3980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:3980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:3980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:3980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:3980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:3980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:3980:EDES NPP MS")
  field(INPB, "YCOR:UNDS:3980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:4080:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:4080:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:4080:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:4080:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:4080:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:4080:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:4080:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:4080:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:4080:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:4080:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:4080:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:4080:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:4080:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:4080:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:4080:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:4080:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:4080:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:4080:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:4080:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:4080:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:4080:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:4080:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:4080:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:4080:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:4080:BMAX")
  field(DOL2, "YCOR:UNDS:4080:BMAX")
  field(DOL3, "YCOR:UNDS:4080:BMAX")
  field(DOL4, "YCOR:UNDS:4080:BMIN")
  field(DOL5, "YCOR:UNDS:4080:BMIN")
  field(DOL6, "YCOR:UNDS:4080:BMIN")
  field(LNK1, "YCOR:UNDS:4080:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:4080:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:4080:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:4080:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:4080:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:4080:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4080:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4080:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:4080:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:4080:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:4080:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4080:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4080:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4080:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4080:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4080:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:4080:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:4080:EDES NPP MS")
  field(INPB, "YCOR:UNDS:4080:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:4180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:4180:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:4180:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:4180:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:4180:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:4180:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:4180:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:4180:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:4180:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:4180:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:4180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:4180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:4180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:4180:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:4180:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:4180:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:4180:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:4180:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:4180:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:4180:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:4180:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:4180:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:4180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:4180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:4180:BMAX")
  field(DOL2, "YCOR:UNDS:4180:BMAX")
  field(DOL3, "YCOR:UNDS:4180:BMAX")
  field(DOL4, "YCOR:UNDS:4180:BMIN")
  field(DOL5, "YCOR:UNDS:4180:BMIN")
  field(DOL6, "YCOR:UNDS:4180:BMIN")
  field(LNK1, "YCOR:UNDS:4180:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:4180:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:4180:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:4180:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:4180:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:4180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:4180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:4180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:4180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:4180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:4180:EDES NPP MS")
  field(INPB, "YCOR:UNDS:4180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:4280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:4280:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:4280:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:4280:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:4280:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:4280:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:4280:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:4280:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:4280:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:4280:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:4280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:4280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:4280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:4280:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:4280:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:4280:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:4280:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:4280:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:4280:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:4280:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:4280:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:4280:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:4280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:4280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:4280:BMAX")
  field(DOL2, "YCOR:UNDS:4280:BMAX")
  field(DOL3, "YCOR:UNDS:4280:BMAX")
  field(DOL4, "YCOR:UNDS:4280:BMIN")
  field(DOL5, "YCOR:UNDS:4280:BMIN")
  field(DOL6, "YCOR:UNDS:4280:BMIN")
  field(LNK1, "YCOR:UNDS:4280:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:4280:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:4280:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:4280:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:4280:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:4280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:4280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:4280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:4280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:4280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:4280:EDES NPP MS")
  field(INPB, "YCOR:UNDS:4280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:4380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:4380:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:4380:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:4380:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:4380:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:4380:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:4380:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:4380:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:4380:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:4380:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:4380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:4380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:4380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:4380:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:4380:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:4380:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:4380:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:4380:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:4380:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:4380:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:4380:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:4380:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:4380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:4380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:4380:BMAX")
  field(DOL2, "YCOR:UNDS:4380:BMAX")
  field(DOL3, "YCOR:UNDS:4380:BMAX")
  field(DOL4, "YCOR:UNDS:4380:BMIN")
  field(DOL5, "YCOR:UNDS:4380:BMIN")
  field(DOL6, "YCOR:UNDS:4380:BMIN")
  field(LNK1, "YCOR:UNDS:4380:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:4380:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:4380:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:4380:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:4380:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:4380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:4380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:4380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:4380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:4380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:4380:EDES NPP MS")
  field(INPB, "YCOR:UNDS:4380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:4480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:4480:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:4480:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:4480:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:4480:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:4480:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:4480:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:4480:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:4480:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:4480:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:4480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:4480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:4480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:4480:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:4480:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:4480:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:4480:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:4480:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:4480:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:4480:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:4480:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:4480:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:4480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:4480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:4480:BMAX")
  field(DOL2, "YCOR:UNDS:4480:BMAX")
  field(DOL3, "YCOR:UNDS:4480:BMAX")
  field(DOL4, "YCOR:UNDS:4480:BMIN")
  field(DOL5, "YCOR:UNDS:4480:BMIN")
  field(DOL6, "YCOR:UNDS:4480:BMIN")
  field(LNK1, "YCOR:UNDS:4480:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:4480:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:4480:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:4480:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:4480:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:4480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:4480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:4480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:4480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:4480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:4480:EDES NPP MS")
  field(INPB, "YCOR:UNDS:4480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:4580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:4580:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:4580:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:4580:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:4580:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:4580:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:4580:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:4580:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:4580:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:4580:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:4580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:4580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:4580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:4580:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:4580:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:4580:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:4580:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:4580:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:4580:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:4580:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:4580:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:4580:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:4580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:4580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:4580:BMAX")
  field(DOL2, "YCOR:UNDS:4580:BMAX")
  field(DOL3, "YCOR:UNDS:4580:BMAX")
  field(DOL4, "YCOR:UNDS:4580:BMIN")
  field(DOL5, "YCOR:UNDS:4580:BMIN")
  field(DOL6, "YCOR:UNDS:4580:BMIN")
  field(LNK1, "YCOR:UNDS:4580:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:4580:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:4580:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:4580:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:4580:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:4580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:4580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:4580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:4580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:4580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:4580:EDES NPP MS")
  field(INPB, "YCOR:UNDS:4580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:4680:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:4680:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:4680:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:4680:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:4680:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:4680:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:4680:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:4680:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:4680:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:4680:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:4680:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:4680:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:4680:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:4680:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:4680:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:4680:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:4680:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:4680:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:4680:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:4680:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:4680:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:4680:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:4680:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:4680:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:4680:BMAX")
  field(DOL2, "YCOR:UNDS:4680:BMAX")
  field(DOL3, "YCOR:UNDS:4680:BMAX")
  field(DOL4, "YCOR:UNDS:4680:BMIN")
  field(DOL5, "YCOR:UNDS:4680:BMIN")
  field(DOL6, "YCOR:UNDS:4680:BMIN")
  field(LNK1, "YCOR:UNDS:4680:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:4680:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:4680:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:4680:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:4680:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:4680:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4680:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4680:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:4680:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:4680:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:4680:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4680:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4680:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4680:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4680:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4680:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:4680:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:4680:EDES NPP MS")
  field(INPB, "YCOR:UNDS:4680:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:UNDS:4780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "YCOR:UNDS:4780:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:UNDS:4780:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:UNDS:4780:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:UNDS:4780:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:UNDS:4780:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:UNDS:4780:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:UNDS:4780:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:UNDS:4780:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:UNDS:4780:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:UNDS:4780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:UNDS:4780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:UNDS:4780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:UNDS:4780:EDES.PROC PP")
    field(LNK2, "YCOR:UNDS:4780:EACT.PROC PP")
    field(LNK3, "YCOR:UNDS:4780:EERR.DISA PP")
    field(LNK4, "YCOR:UNDS:4780:ECON.PROC PP")
    field(LNK5, "YCOR:UNDS:4780:BMAGX.PROC PP")
    field(LNK6, "YCOR:UNDS:4780:BMAGY.PROC PP")
    field(LNK7, "YCOR:UNDS:4780:BLEM.PROC PP")
    field(LNK8, "YCOR:UNDS:4780:BMOD.PROC PP")
    field(LNK9, "YCOR:UNDS:4780:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:UNDS:4780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:UNDS:4780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:UNDS:4780:BMAX")
  field(DOL2, "YCOR:UNDS:4780:BMAX")
  field(DOL3, "YCOR:UNDS:4780:BMAX")
  field(DOL4, "YCOR:UNDS:4780:BMIN")
  field(DOL5, "YCOR:UNDS:4780:BMIN")
  field(DOL6, "YCOR:UNDS:4780:BMIN")
  field(LNK1, "YCOR:UNDS:4780:BMAGX.HOPR")
  field(LNK2, "YCOR:UNDS:4780:BMAGY.HOPR")
  field(LNK3, "YCOR:UNDS:4780:BLEM.HOPR")
  field(LNK4, "YCOR:UNDS:4780:BMAGX.LOPR PP")
  field(LNK5, "YCOR:UNDS:4780:BMAGY.LOPR PP")
  field(LNK6, "YCOR:UNDS:4780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:UNDS:4780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:UNDS:4780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:UNDS:4780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:UNDS:4780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:UNDS:4780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:UNDS:4780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:UNDS:4780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:UNDS:4780:EDES NPP MS")
  field(INPB, "YCOR:UNDS:4780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDH:1355:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDH:1355:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDH:1355:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDH:1355:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDH:1355:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDH:1355:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDH:1355:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDH:1355:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDH:1355:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDH:1355:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDH:1355:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDH:1355:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDH:1355:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDH:1355:EDES.PROC PP")
    field(LNK2, "BEND:UNDH:1355:EACT.PROC PP")
    field(LNK3, "BEND:UNDH:1355:EERR.DISA PP")
    field(LNK4, "BEND:UNDH:1355:ECON.PROC PP")
    field(LNK5, "BEND:UNDH:1355:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDH:1355:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDH:1355:BLEM.PROC PP")
    field(LNK8, "BEND:UNDH:1355:BMOD.PROC PP")
    field(LNK9, "BEND:UNDH:1355:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDH:1355:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDH:1355:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDH:1355:BMAX")
  field(DOL2, "BEND:UNDH:1355:BMAX")
  field(DOL3, "BEND:UNDH:1355:BMAX")
  field(DOL4, "BEND:UNDH:1355:BMIN")
  field(DOL5, "BEND:UNDH:1355:BMIN")
  field(DOL6, "BEND:UNDH:1355:BMIN")
  field(LNK1, "BEND:UNDH:1355:BMAGX.HOPR")
  field(LNK2, "BEND:UNDH:1355:BMAGY.HOPR")
  field(LNK3, "BEND:UNDH:1355:BLEM.HOPR")
  field(LNK4, "BEND:UNDH:1355:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDH:1355:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDH:1355:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:1355:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:1355:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDH:1355:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDH:1355:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDH:1355:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:1355:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:UNDH:1330:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:1355:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:1330:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:1355:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:1355:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:1330:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:1355:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDH:1355:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDH:1355:EDES NPP MS")
  field(INPB, "BEND:UNDH:1355:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDH:1360:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDH:1360:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDH:1360:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDH:1360:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDH:1360:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDH:1360:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDH:1360:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDH:1360:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDH:1360:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDH:1360:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDH:1360:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDH:1360:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDH:1360:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDH:1360:EDES.PROC PP")
    field(LNK2, "BEND:UNDH:1360:EACT.PROC PP")
    field(LNK3, "BEND:UNDH:1360:EERR.DISA PP")
    field(LNK4, "BEND:UNDH:1360:ECON.PROC PP")
    field(LNK5, "BEND:UNDH:1360:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDH:1360:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDH:1360:BLEM.PROC PP")
    field(LNK8, "BEND:UNDH:1360:BMOD.PROC PP")
    field(LNK9, "BEND:UNDH:1360:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDH:1360:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDH:1360:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDH:1360:BMAX")
  field(DOL2, "BEND:UNDH:1360:BMAX")
  field(DOL3, "BEND:UNDH:1360:BMAX")
  field(DOL4, "BEND:UNDH:1360:BMIN")
  field(DOL5, "BEND:UNDH:1360:BMIN")
  field(DOL6, "BEND:UNDH:1360:BMIN")
  field(LNK1, "BEND:UNDH:1360:BMAGX.HOPR")
  field(LNK2, "BEND:UNDH:1360:BMAGY.HOPR")
  field(LNK3, "BEND:UNDH:1360:BLEM.HOPR")
  field(LNK4, "BEND:UNDH:1360:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDH:1360:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDH:1360:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:1360:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:1360:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDH:1360:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDH:1360:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDH:1360:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:1360:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:UNDH:1330:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:1360:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:1330:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:1360:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:1360:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:1330:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:1360:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDH:1360:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDH:1360:EDES NPP MS")
  field(INPB, "BEND:UNDH:1360:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDH:1375:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDH:1375:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDH:1375:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDH:1375:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDH:1375:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDH:1375:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDH:1375:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDH:1375:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDH:1375:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDH:1375:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDH:1375:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDH:1375:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDH:1375:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDH:1375:EDES.PROC PP")
    field(LNK2, "BEND:UNDH:1375:EACT.PROC PP")
    field(LNK3, "BEND:UNDH:1375:EERR.DISA PP")
    field(LNK4, "BEND:UNDH:1375:ECON.PROC PP")
    field(LNK5, "BEND:UNDH:1375:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDH:1375:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDH:1375:BLEM.PROC PP")
    field(LNK8, "BEND:UNDH:1375:BMOD.PROC PP")
    field(LNK9, "BEND:UNDH:1375:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDH:1375:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDH:1375:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDH:1375:BMAX")
  field(DOL2, "BEND:UNDH:1375:BMAX")
  field(DOL3, "BEND:UNDH:1375:BMAX")
  field(DOL4, "BEND:UNDH:1375:BMIN")
  field(DOL5, "BEND:UNDH:1375:BMIN")
  field(DOL6, "BEND:UNDH:1375:BMIN")
  field(LNK1, "BEND:UNDH:1375:BMAGX.HOPR")
  field(LNK2, "BEND:UNDH:1375:BMAGY.HOPR")
  field(LNK3, "BEND:UNDH:1375:BLEM.HOPR")
  field(LNK4, "BEND:UNDH:1375:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDH:1375:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDH:1375:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:1375:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:1375:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDH:1375:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDH:1375:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDH:1375:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:1375:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:UNDH:1330:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:1375:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:1330:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:1375:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:1375:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:1330:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:1375:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDH:1375:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDH:1375:EDES NPP MS")
  field(INPB, "BEND:UNDH:1375:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDH:2155:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDH:2155:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDH:2155:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDH:2155:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDH:2155:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDH:2155:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDH:2155:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDH:2155:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDH:2155:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDH:2155:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDH:2155:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDH:2155:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDH:2155:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDH:2155:EDES.PROC PP")
    field(LNK2, "BEND:UNDH:2155:EACT.PROC PP")
    field(LNK3, "BEND:UNDH:2155:EERR.DISA PP")
    field(LNK4, "BEND:UNDH:2155:ECON.PROC PP")
    field(LNK5, "BEND:UNDH:2155:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDH:2155:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDH:2155:BLEM.PROC PP")
    field(LNK8, "BEND:UNDH:2155:BMOD.PROC PP")
    field(LNK9, "BEND:UNDH:2155:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDH:2155:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDH:2155:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDH:2155:BMAX")
  field(DOL2, "BEND:UNDH:2155:BMAX")
  field(DOL3, "BEND:UNDH:2155:BMAX")
  field(DOL4, "BEND:UNDH:2155:BMIN")
  field(DOL5, "BEND:UNDH:2155:BMIN")
  field(DOL6, "BEND:UNDH:2155:BMIN")
  field(LNK1, "BEND:UNDH:2155:BMAGX.HOPR")
  field(LNK2, "BEND:UNDH:2155:BMAGY.HOPR")
  field(LNK3, "BEND:UNDH:2155:BLEM.HOPR")
  field(LNK4, "BEND:UNDH:2155:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDH:2155:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDH:2155:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2155:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2155:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDH:2155:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDH:2155:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDH:2155:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2155:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:UNDH:2130:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2155:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:2130:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:2155:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2155:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:2130:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:2155:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDH:2155:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDH:2155:EDES NPP MS")
  field(INPB, "BEND:UNDH:2155:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDH:2160:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDH:2160:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDH:2160:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDH:2160:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDH:2160:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDH:2160:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDH:2160:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDH:2160:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDH:2160:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDH:2160:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDH:2160:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDH:2160:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDH:2160:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDH:2160:EDES.PROC PP")
    field(LNK2, "BEND:UNDH:2160:EACT.PROC PP")
    field(LNK3, "BEND:UNDH:2160:EERR.DISA PP")
    field(LNK4, "BEND:UNDH:2160:ECON.PROC PP")
    field(LNK5, "BEND:UNDH:2160:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDH:2160:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDH:2160:BLEM.PROC PP")
    field(LNK8, "BEND:UNDH:2160:BMOD.PROC PP")
    field(LNK9, "BEND:UNDH:2160:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDH:2160:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDH:2160:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDH:2160:BMAX")
  field(DOL2, "BEND:UNDH:2160:BMAX")
  field(DOL3, "BEND:UNDH:2160:BMAX")
  field(DOL4, "BEND:UNDH:2160:BMIN")
  field(DOL5, "BEND:UNDH:2160:BMIN")
  field(DOL6, "BEND:UNDH:2160:BMIN")
  field(LNK1, "BEND:UNDH:2160:BMAGX.HOPR")
  field(LNK2, "BEND:UNDH:2160:BMAGY.HOPR")
  field(LNK3, "BEND:UNDH:2160:BLEM.HOPR")
  field(LNK4, "BEND:UNDH:2160:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDH:2160:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDH:2160:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2160:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2160:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDH:2160:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDH:2160:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDH:2160:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2160:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:UNDH:2130:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2160:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:2130:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:2160:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2160:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:2130:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:2160:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDH:2160:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDH:2160:EDES NPP MS")
  field(INPB, "BEND:UNDH:2160:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDH:2175:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDH:2175:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDH:2175:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDH:2175:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDH:2175:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDH:2175:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDH:2175:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDH:2175:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDH:2175:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDH:2175:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDH:2175:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDH:2175:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDH:2175:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDH:2175:EDES.PROC PP")
    field(LNK2, "BEND:UNDH:2175:EACT.PROC PP")
    field(LNK3, "BEND:UNDH:2175:EERR.DISA PP")
    field(LNK4, "BEND:UNDH:2175:ECON.PROC PP")
    field(LNK5, "BEND:UNDH:2175:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDH:2175:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDH:2175:BLEM.PROC PP")
    field(LNK8, "BEND:UNDH:2175:BMOD.PROC PP")
    field(LNK9, "BEND:UNDH:2175:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDH:2175:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDH:2175:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDH:2175:BMAX")
  field(DOL2, "BEND:UNDH:2175:BMAX")
  field(DOL3, "BEND:UNDH:2175:BMAX")
  field(DOL4, "BEND:UNDH:2175:BMIN")
  field(DOL5, "BEND:UNDH:2175:BMIN")
  field(DOL6, "BEND:UNDH:2175:BMIN")
  field(LNK1, "BEND:UNDH:2175:BMAGX.HOPR")
  field(LNK2, "BEND:UNDH:2175:BMAGY.HOPR")
  field(LNK3, "BEND:UNDH:2175:BLEM.HOPR")
  field(LNK4, "BEND:UNDH:2175:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDH:2175:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDH:2175:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2175:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2175:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDH:2175:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDH:2175:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDH:2175:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2175:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:UNDH:2130:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2175:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:2130:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:2175:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2175:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:2130:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:2175:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDH:2175:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDH:2175:EDES NPP MS")
  field(INPB, "BEND:UNDH:2175:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDH:2830:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDH:2830:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDH:2830:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDH:2830:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDH:2830:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDH:2830:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDH:2830:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDH:2830:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDH:2830:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDH:2830:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDH:2830:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDH:2830:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDH:2830:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDH:2830:EDES.PROC PP")
    field(LNK2, "BEND:UNDH:2830:EACT.PROC PP")
    field(LNK3, "BEND:UNDH:2830:EERR.DISA PP")
    field(LNK4, "BEND:UNDH:2830:ECON.PROC PP")
    field(LNK5, "BEND:UNDH:2830:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDH:2830:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDH:2830:BLEM.PROC PP")
    field(LNK8, "BEND:UNDH:2830:BMOD.PROC PP")
    field(LNK9, "BEND:UNDH:2830:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDH:2830:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDH:2830:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDH:2830:BMAX")
  field(DOL2, "BEND:UNDH:2830:BMAX")
  field(DOL3, "BEND:UNDH:2830:BMAX")
  field(DOL4, "BEND:UNDH:2830:BMIN")
  field(DOL5, "BEND:UNDH:2830:BMIN")
  field(DOL6, "BEND:UNDH:2830:BMIN")
  field(LNK1, "BEND:UNDH:2830:BMAGX.HOPR")
  field(LNK2, "BEND:UNDH:2830:BMAGY.HOPR")
  field(LNK3, "BEND:UNDH:2830:BLEM.HOPR")
  field(LNK4, "BEND:UNDH:2830:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDH:2830:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDH:2830:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2830:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2830:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDH:2830:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDH:2830:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDH:2830:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2830:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:UNDH:2810:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2830:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:2810:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:2830:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2830:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:2810:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:2830:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDH:2830:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDH:2830:EDES NPP MS")
  field(INPB, "BEND:UNDH:2830:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDH:2850:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDH:2850:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDH:2850:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDH:2850:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDH:2850:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDH:2850:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDH:2850:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDH:2850:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDH:2850:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDH:2850:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDH:2850:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDH:2850:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDH:2850:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDH:2850:EDES.PROC PP")
    field(LNK2, "BEND:UNDH:2850:EACT.PROC PP")
    field(LNK3, "BEND:UNDH:2850:EERR.DISA PP")
    field(LNK4, "BEND:UNDH:2850:ECON.PROC PP")
    field(LNK5, "BEND:UNDH:2850:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDH:2850:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDH:2850:BLEM.PROC PP")
    field(LNK8, "BEND:UNDH:2850:BMOD.PROC PP")
    field(LNK9, "BEND:UNDH:2850:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDH:2850:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDH:2850:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDH:2850:BMAX")
  field(DOL2, "BEND:UNDH:2850:BMAX")
  field(DOL3, "BEND:UNDH:2850:BMAX")
  field(DOL4, "BEND:UNDH:2850:BMIN")
  field(DOL5, "BEND:UNDH:2850:BMIN")
  field(DOL6, "BEND:UNDH:2850:BMIN")
  field(LNK1, "BEND:UNDH:2850:BMAGX.HOPR")
  field(LNK2, "BEND:UNDH:2850:BMAGY.HOPR")
  field(LNK3, "BEND:UNDH:2850:BLEM.HOPR")
  field(LNK4, "BEND:UNDH:2850:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDH:2850:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDH:2850:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2850:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2850:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDH:2850:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDH:2850:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDH:2850:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2850:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:UNDH:2810:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2850:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:2810:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:2850:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2850:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:2810:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:2850:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDH:2850:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDH:2850:EDES NPP MS")
  field(INPB, "BEND:UNDH:2850:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDH:2870:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDH:2870:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDH:2870:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDH:2870:FUNC CA PP")
  field(DOL4, "MGNT:UNDH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDH:2870:FUNC CA PP")
  field(DOL5, "MGNT:UNDH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDH:2870:FUNC CA PP")
  field(DOL6, "MGNT:UNDH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDH:2870:FUNC CA PP")
  field(DOL7, "MGNT:UNDH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDH:2870:FUNC CA PP")
  field(DOL8, "MGNT:UNDH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDH:2870:FUNC CA PP")
  field(DOL9, "MGNT:UNDH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDH:2870:FUNC CA PP")
  field(DOLA, "MGNT:UNDH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDH:2870:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDH:2870:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDH:2870:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDH:2870:EDES.PROC PP")
    field(LNK2, "BEND:UNDH:2870:EACT.PROC PP")
    field(LNK3, "BEND:UNDH:2870:EERR.DISA PP")
    field(LNK4, "BEND:UNDH:2870:ECON.PROC PP")
    field(LNK5, "BEND:UNDH:2870:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDH:2870:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDH:2870:BLEM.PROC PP")
    field(LNK8, "BEND:UNDH:2870:BMOD.PROC PP")
    field(LNK9, "BEND:UNDH:2870:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDH:2870:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDH:2870:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDH:2870:BMAX")
  field(DOL2, "BEND:UNDH:2870:BMAX")
  field(DOL3, "BEND:UNDH:2870:BMAX")
  field(DOL4, "BEND:UNDH:2870:BMIN")
  field(DOL5, "BEND:UNDH:2870:BMIN")
  field(DOL6, "BEND:UNDH:2870:BMIN")
  field(LNK1, "BEND:UNDH:2870:BMAGX.HOPR")
  field(LNK2, "BEND:UNDH:2870:BMAGY.HOPR")
  field(LNK3, "BEND:UNDH:2870:BLEM.HOPR")
  field(LNK4, "BEND:UNDH:2870:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDH:2870:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDH:2870:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2870:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDH:2870:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDH:2870:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDH:2870:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDH:2870:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2870:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:UNDH:2810:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2870:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:2810:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:2870:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDH:2870:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:UNDH:2810:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDH:2870:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDH:2870:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDH:2870:EDES NPP MS")
  field(INPB, "BEND:UNDH:2870:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDS:3530:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDS:3530:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDS:3530:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDS:3530:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDS:3530:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDS:3530:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDS:3530:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDS:3530:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDS:3530:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDS:3530:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDS:3530:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDS:3530:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDS:3530:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDS:3530:EDES.PROC PP")
    field(LNK2, "BEND:UNDS:3530:EACT.PROC PP")
    field(LNK3, "BEND:UNDS:3530:EERR.DISA PP")
    field(LNK4, "BEND:UNDS:3530:ECON.PROC PP")
    field(LNK5, "BEND:UNDS:3530:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDS:3530:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDS:3530:BLEM.PROC PP")
    field(LNK8, "BEND:UNDS:3530:BMOD.PROC PP")
    field(LNK9, "BEND:UNDS:3530:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDS:3530:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDS:3530:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDS:3530:BMAX")
  field(DOL2, "BEND:UNDS:3530:BMAX")
  field(DOL3, "BEND:UNDS:3530:BMAX")
  field(DOL4, "BEND:UNDS:3530:BMIN")
  field(DOL5, "BEND:UNDS:3530:BMIN")
  field(DOL6, "BEND:UNDS:3530:BMIN")
  field(LNK1, "BEND:UNDS:3530:BMAGX.HOPR")
  field(LNK2, "BEND:UNDS:3530:BMAGY.HOPR")
  field(LNK3, "BEND:UNDS:3530:BLEM.HOPR")
  field(LNK4, "BEND:UNDS:3530:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDS:3530:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDS:3530:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDS:3530:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDS:3530:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDS:3530:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDS:3530:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDS:3530:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDS:3530:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:UNDS:3510:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDS:3530:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:UNDS:3510:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDS:3530:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDS:3530:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:UNDS:3510:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDS:3530:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDS:3530:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDS:3530:EDES NPP MS")
  field(INPB, "BEND:UNDS:3530:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDS:3550:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDS:3550:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDS:3550:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDS:3550:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDS:3550:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDS:3550:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDS:3550:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDS:3550:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDS:3550:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDS:3550:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDS:3550:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDS:3550:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDS:3550:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDS:3550:EDES.PROC PP")
    field(LNK2, "BEND:UNDS:3550:EACT.PROC PP")
    field(LNK3, "BEND:UNDS:3550:EERR.DISA PP")
    field(LNK4, "BEND:UNDS:3550:ECON.PROC PP")
    field(LNK5, "BEND:UNDS:3550:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDS:3550:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDS:3550:BLEM.PROC PP")
    field(LNK8, "BEND:UNDS:3550:BMOD.PROC PP")
    field(LNK9, "BEND:UNDS:3550:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDS:3550:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDS:3550:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDS:3550:BMAX")
  field(DOL2, "BEND:UNDS:3550:BMAX")
  field(DOL3, "BEND:UNDS:3550:BMAX")
  field(DOL4, "BEND:UNDS:3550:BMIN")
  field(DOL5, "BEND:UNDS:3550:BMIN")
  field(DOL6, "BEND:UNDS:3550:BMIN")
  field(LNK1, "BEND:UNDS:3550:BMAGX.HOPR")
  field(LNK2, "BEND:UNDS:3550:BMAGY.HOPR")
  field(LNK3, "BEND:UNDS:3550:BLEM.HOPR")
  field(LNK4, "BEND:UNDS:3550:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDS:3550:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDS:3550:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDS:3550:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDS:3550:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDS:3550:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDS:3550:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDS:3550:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDS:3550:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:UNDS:3510:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDS:3550:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:UNDS:3510:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDS:3550:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDS:3550:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:UNDS:3510:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDS:3550:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDS:3550:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDS:3550:EDES NPP MS")
  field(INPB, "BEND:UNDS:3550:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:UNDS:3570:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "BEND:UNDS:3570:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:UNDS:3570:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:UNDS:3570:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:UNDS:3570:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:UNDS:3570:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:UNDS:3570:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:UNDS:3570:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:UNDS:3570:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:UNDS:3570:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:UNDS:3570:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:UNDS:3570:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:UNDS:3570:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:UNDS:3570:EDES.PROC PP")
    field(LNK2, "BEND:UNDS:3570:EACT.PROC PP")
    field(LNK3, "BEND:UNDS:3570:EERR.DISA PP")
    field(LNK4, "BEND:UNDS:3570:ECON.PROC PP")
    field(LNK5, "BEND:UNDS:3570:BMAGX.PROC PP")
    field(LNK6, "BEND:UNDS:3570:BMAGY.PROC PP")
    field(LNK7, "BEND:UNDS:3570:BLEM.PROC PP")
    field(LNK8, "BEND:UNDS:3570:BMOD.PROC PP")
    field(LNK9, "BEND:UNDS:3570:EDESSAVE.PROC PP")
    field(LNKA, "BEND:UNDS:3570:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:UNDS:3570:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:UNDS:3570:BMAX")
  field(DOL2, "BEND:UNDS:3570:BMAX")
  field(DOL3, "BEND:UNDS:3570:BMAX")
  field(DOL4, "BEND:UNDS:3570:BMIN")
  field(DOL5, "BEND:UNDS:3570:BMIN")
  field(DOL6, "BEND:UNDS:3570:BMIN")
  field(LNK1, "BEND:UNDS:3570:BMAGX.HOPR")
  field(LNK2, "BEND:UNDS:3570:BMAGY.HOPR")
  field(LNK3, "BEND:UNDS:3570:BLEM.HOPR")
  field(LNK4, "BEND:UNDS:3570:BMAGX.LOPR PP")
  field(LNK5, "BEND:UNDS:3570:BMAGY.LOPR PP")
  field(LNK6, "BEND:UNDS:3570:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:UNDS:3570:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:UNDS:3570:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:UNDS:3570:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:UNDS:3570:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:UNDS:3570:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDS:3570:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:UNDS:3510:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDS:3570:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:UNDS:3510:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDS:3570:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:UNDS:3570:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:UNDS:3510:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:UNDS:3570:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:UNDS:3570:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:UNDS:3570:EDES NPP MS")
  field(INPB, "BEND:UNDS:3570:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:5002:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:5002:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:5002:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:5002:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:5002:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:5002:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:5002:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:5002:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:5002:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:5002:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:5002:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:5002:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:5002:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:5002:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:5002:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:5002:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:5002:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:5002:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:5002:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:5002:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:5002:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:5002:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:5002:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:5002:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:5002:BMAX")
  field(DOL2, "XCOR:UNDS:5002:BMAX")
  field(DOL3, "XCOR:UNDS:5002:BMAX")
  field(DOL4, "XCOR:UNDS:5002:BMIN")
  field(DOL5, "XCOR:UNDS:5002:BMIN")
  field(DOL6, "XCOR:UNDS:5002:BMIN")
  field(LNK1, "XCOR:UNDS:5002:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:5002:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:5002:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:5002:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:5002:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:5002:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:5002:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:5002:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:5002:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:5002:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:5002:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:5002:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "XCOR:UNDS:4982:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:5002:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "XCOR:UNDS:4982:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:UNDS:5002:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:5002:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "XCOR:UNDS:4982:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:UNDS:5002:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:5002:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:5002:EDES NPP MS")
  field(INPB, "XCOR:UNDS:5002:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:UNDS:5022:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:1:CTRL.RVAL")
  field(LNK1, "XCOR:UNDS:5022:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:UNDS:5022:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:UNDS:5022:FUNC CA PP")
  field(DOL4, "MGNT:UNDS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:UNDS:5022:FUNC CA PP")
  field(DOL5, "MGNT:UNDS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:UNDS:5022:FUNC CA PP")
  field(DOL6, "MGNT:UNDS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:UNDS:5022:FUNC CA PP")
  field(DOL7, "MGNT:UNDS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:UNDS:5022:FUNC CA PP")
  field(DOL8, "MGNT:UNDS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:UNDS:5022:FUNC CA PP")
  field(DOL9, "MGNT:UNDS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:UNDS:5022:FUNC CA PP")
  field(DOLA, "MGNT:UNDS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:UNDS:5022:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:UNDS:5022:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:UNDS:5022:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:UNDS:5022:EDES.PROC PP")
    field(LNK2, "XCOR:UNDS:5022:EACT.PROC PP")
    field(LNK3, "XCOR:UNDS:5022:EERR.DISA PP")
    field(LNK4, "XCOR:UNDS:5022:ECON.PROC PP")
    field(LNK5, "XCOR:UNDS:5022:BMAGX.PROC PP")
    field(LNK6, "XCOR:UNDS:5022:BMAGY.PROC PP")
    field(LNK7, "XCOR:UNDS:5022:BLEM.PROC PP")
    field(LNK8, "XCOR:UNDS:5022:BMOD.PROC PP")
    field(LNK9, "XCOR:UNDS:5022:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:UNDS:5022:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:UNDS:5022:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:UNDS:5022:BMAX")
  field(DOL2, "XCOR:UNDS:5022:BMAX")
  field(DOL3, "XCOR:UNDS:5022:BMAX")
  field(DOL4, "XCOR:UNDS:5022:BMIN")
  field(DOL5, "XCOR:UNDS:5022:BMIN")
  field(DOL6, "XCOR:UNDS:5022:BMIN")
  field(LNK1, "XCOR:UNDS:5022:BMAGX.HOPR")
  field(LNK2, "XCOR:UNDS:5022:BMAGY.HOPR")
  field(LNK3, "XCOR:UNDS:5022:BLEM.HOPR")
  field(LNK4, "XCOR:UNDS:5022:BMAGX.LOPR PP")
  field(LNK5, "XCOR:UNDS:5022:BMAGY.LOPR PP")
  field(LNK6, "XCOR:UNDS:5022:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:5022:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:UNDS:5022:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:UNDS:5022:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:UNDS:5022:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:UNDS:5022:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:5022:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "XCOR:UNDS:4982:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:5022:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "XCOR:UNDS:4982:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:UNDS:5022:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:UNDS:5022:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "XCOR:UNDS:4982:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:UNDS:5022:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:UNDS:5022:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:UNDS:5022:EDES NPP MS")
  field(INPB, "XCOR:UNDS:5022:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:1450:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:1450:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:1450:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:1450:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:1450:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:1550:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:1550:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:1550:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:1550:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:1550:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:1650:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:1650:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:1650:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:1650:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:1650:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:1750:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:1750:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:1750:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:1750:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:1750:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:1850:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:1850:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:1850:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:1850:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:1850:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:1950:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:1950:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:1950:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:1950:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:1950:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2050:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2050:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2050:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2050:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2050:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2250:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2250:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2250:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2250:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2250:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2350:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2350:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2350:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2350:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2350:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2450:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2450:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2450:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2450:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2450:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2550:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2550:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2550:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2550:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2550:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2650:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2650:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2650:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2650:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2650:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2750:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2750:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2750:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2750:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2750:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2950:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2950:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2950:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2950:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2950:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3050:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3050:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3050:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3050:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3050:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3150:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3150:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3150:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3150:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3150:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3250:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3250:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3250:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3250:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3250:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3350:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3350:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3350:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3350:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3350:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3450:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3450:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3450:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3450:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3450:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3550:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3550:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3550:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3550:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3550:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3650:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3650:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3650:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3650:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3650:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3750:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3750:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3750:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3750:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3750:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3850:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3850:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3850:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3850:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3850:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3950:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3950:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3950:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3950:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3950:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4050:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4050:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4050:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4050:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4050:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4150:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4150:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4150:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4150:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4150:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4250:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4250:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4250:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4250:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4250:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4350:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4350:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4350:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4350:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4350:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4450:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4450:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4450:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4450:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4450:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4450:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4450:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4450:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4450:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4450:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4550:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4550:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4550:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4550:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4550:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4650:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4650:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4650:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4650:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4650:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4750:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4750:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4750:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4750:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4750:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:1450:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:1450:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:1450:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:1450:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:1450:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:1550:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:1550:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:1550:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:1550:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:1550:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:1650:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:1650:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:1650:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:1650:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:1650:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:1750:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:1750:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:1750:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:1750:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:1750:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:1850:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:1850:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:1850:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:1850:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:1850:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:1950:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:1950:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:1950:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:1950:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:1950:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2050:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2050:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2050:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2050:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2050:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2250:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2250:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2250:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2250:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2250:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2350:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2350:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2350:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2350:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2350:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2450:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2450:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2450:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2450:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2450:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2550:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2550:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2550:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2550:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2550:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2650:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2650:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2650:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2650:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2650:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2750:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2750:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2750:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2750:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2750:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:2950:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:2950:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:2950:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:2950:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:2950:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3050:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3050:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3050:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3050:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3050:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3150:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3150:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3150:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3150:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3150:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3250:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3250:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3250:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3250:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3250:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3350:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3350:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3350:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3350:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3350:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3450:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3450:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3450:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3450:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3450:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3550:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3550:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3550:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3550:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3550:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3650:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3650:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3650:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3650:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3650:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3750:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3750:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3750:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3750:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3750:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3850:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3850:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3850:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3850:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3850:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:3950:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:3950:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:3950:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:3950:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:3950:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4050:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4050:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4050:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4050:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4050:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4150:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4150:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4150:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4150:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4150:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4250:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4250:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4250:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4250:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4250:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4350:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4350:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4350:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4350:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4350:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4450:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4450:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4450:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4450:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4450:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4450:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4450:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4450:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4450:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4450:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4550:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4550:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4550:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4550:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4550:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4650:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4650:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4650:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4650:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4650:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDH:4750:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDH:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDH:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDH:4750:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDH:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDH:4750:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDH:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDH:4750:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDH:4750:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:2650:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:2650:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:2650:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:2650:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:2650:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:2750:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:2750:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:2750:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:2750:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:2750:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:2850:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:2850:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:2850:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:2850:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:2850:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:2950:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:2950:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:2950:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:2950:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:2950:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3050:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3050:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3050:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3050:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3050:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3150:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3150:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3150:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3150:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3150:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3250:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3250:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3250:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3250:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3250:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3350:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3350:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3350:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3350:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3350:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3450:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3450:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3450:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3450:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3450:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3650:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3650:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3650:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3650:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3650:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3750:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3750:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3750:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3750:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3750:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3850:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3850:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3850:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3850:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3850:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3950:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3950:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3950:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3950:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3950:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4050:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4050:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4050:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4050:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4050:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4150:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4150:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4150:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4150:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4150:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4250:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4250:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4250:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4250:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4250:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4350:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4350:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4350:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4350:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4350:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4450:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4450:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4450:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4450:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4450:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4450:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4450:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4450:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4450:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4450:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4550:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4550:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4550:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4550:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4550:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4650:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4650:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4650:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4650:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4650:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4750:X:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4750:X:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4750:X:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4750:X:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4750:X:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:2650:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:2650:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:2650:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:2650:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:2650:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:2750:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:2750:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:2750:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:2750:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:2750:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:2850:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:2850:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:2850:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:2850:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:2850:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:2950:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:2950:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:2950:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:2950:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:2950:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3050:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3050:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3050:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3050:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3050:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3150:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3150:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3150:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3150:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3150:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3250:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3250:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3250:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3250:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3250:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3350:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3350:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3350:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3350:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3350:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3450:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3450:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3450:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3450:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3450:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3650:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3650:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3650:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3650:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3650:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3750:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3750:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3750:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3750:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3750:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3850:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3850:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3850:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3850:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3850:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:3950:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:3950:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:3950:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:3950:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:3950:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4050:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4050:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4050:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4050:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4050:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4150:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4150:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4150:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4150:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4150:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4250:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4250:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4250:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4250:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4250:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4350:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4350:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4350:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4350:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4350:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4450:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4450:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4450:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4450:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4450:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4450:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4450:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4450:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4450:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4450:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4550:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4550:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4550:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4550:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4550:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4650:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4650:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4650:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4650:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4650:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "EFC:UNDS:4750:Y:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:UNDS:2:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:UNDS:2:CTRL.RVAL")
  field(LNK1, "EFC:UNDS:4750:Y:FUNC CA PP")
  field(DOL2, "MGNT:UNDS:2:XCORCTRL.RVAL")
  field(LNK2, "EFC:UNDS:4750:Y:FUNC CA PP")
  field(DOL3, "MGNT:UNDS:2:YCORCTRL.RVAL")
  field(LNK3, "EFC:UNDS:4750:Y:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "EFC:UNDS:4750:Y:SELECT CPP")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:DMPH:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:DMPH:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:DMPH:1:CTRL CA PP")
  field(LNK2, "MGNT:DMPH:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:DMPH:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:DMPH:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:DMPH:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:DMPH:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:DMPH:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:DMPH:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:DMPH:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:DMPH:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:DMPH:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:DMPH:1:ALLSWITCH")
}

record(seq, "MGNT:DMPH:1:ALLSWITCH") {
  field(DOL1, "MGNT:DMPH:1:CTRL.FFVL")
  field(LNK1, "MGNT:DMPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPH:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPH:1:CTRL")
}

record(bo, "MGNT:DMPH:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:DMPH:1:ALLSTARGO")
}

record(fanout, "MGNT:DMPH:1:ALLSTARGO") {
  field(LNK1, "MGNT:DMPH:1:ALLBENDSGO")
  field(LNK2, "MGNT:DMPH:1:ALLBTRMSGO")
  field(LNK3, "MGNT:DMPH:1:ALLLGPSSGO")
  field(LNK4, "MGNT:DMPH:1:ALLQUADSGO")
  field(LNK5, "MGNT:DMPH:1:ALLXCORSGO")
  field(LNK6, "MGNT:DMPH:1:ALLYCORSGO")
  field(FLNK, "MGNT:DMPH:1:ALLSTARGO_2")
}
record(fanout, "MGNT:DMPH:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:DMPH:1:ALLSOLNSGO")
  field(LNK2, "MGNT:DMPH:1:ALLKICKSGO")
  field(LNK3, "MGNT:DMPH:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:DMPH:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:DMPH:1:BENDSWITCH")
}

record(seq, "MGNT:DMPH:1:BENDSWITCH") {
  field(DOL1, "MGNT:DMPH:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:DMPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPH:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPH:1:BENDCTRL")
}

record(seq, "MGNT:DMPH:1:ALLBENDSGO") {
  field(DOL1, "MGNT:DMPH:1:ALLSTAR")
  field(LNK1, "MGNT:DMPH:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:DMPH:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPH:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPH:1:BENDCTRL",20,10,0,0,"MGNT:DMPH:1:BENDCTRL")
#! Field("MGNT:DMPH:1:BENDCTRL.FLNK",16777215,1,"MGNT:DMPH:1:BENDCTRL.FLNK")
#! Link("MGNT:DMPH:1:BENDCTRL.FLNK","MGNT:DMPH:1:BENDSWITCH")
#! Field("MGNT:DMPH:1:BENDCTRL.FFVL",16777215,1,"MGNT:DMPH:1:BENDCTRL.FFVL")
#! Record("MGNT:DMPH:1:BENDSWITCH",460,322,0,0,"MGNT:DMPH:1:BENDSWITCH")
#! Field("MGNT:DMPH:1:BENDSWITCH.DOL1",16777215,0,"MGNT:DMPH:1:BENDSWITCH.DOL1")
#! Link("MGNT:DMPH:1:BENDSWITCH.DOL1","MGNT:DMPH:1:BENDCTRL.FFVL")
#! Field("MGNT:DMPH:1:BENDSWITCH.LNK1",16777215,1,"MGNT:DMPH:1:BENDSWITCH.LNK1")
#! Field("MGNT:DMPH:1:BENDSWITCH.FLNK",16777215,1,"MGNT:DMPH:1:BENDSWITCH.FLNK")
#! Record("MGNT:DMPH:1:ALLBENDSGO",240,96,0,0,"MGNT:DMPH:1:ALLBENDSGO")
#! Field("MGNT:DMPH:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:DMPH:1:ALLBENDSGO.DOL1")
#! Field("MGNT:DMPH:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:DMPH:1:ALLBENDSGO.LNK1")
#! Link("MGNT:DMPH:1:ALLBENDSGO.LNK1","MGNT:DMPH:1:ALLBENDS.VAL")
#! Record("MGNT:DMPH:1:ALLBENDS",540,102,0,0,"MGNT:DMPH:1:ALLBENDS")
#! Field("MGNT:DMPH:1:ALLBENDS.VAL",16777215,0,"MGNT:DMPH:1:ALLBENDS.VAL")
#! Field("MGNT:DMPH:1:ALLBENDS.FLNK",16777215,1,"MGNT:DMPH:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:DMPH:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:DMPH:1:BTRMSWITCH")
}

record(seq, "MGNT:DMPH:1:BTRMSWITCH") {
  field(DOL1, "MGNT:DMPH:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:DMPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPH:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPH:1:BTRMCTRL")
}

record(seq, "MGNT:DMPH:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:DMPH:1:ALLSTAR")
  field(LNK1, "MGNT:DMPH:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:DMPH:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPH:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPH:1:BTRMCTRL",20,10,0,0,"MGNT:DMPH:1:BTRMCTRL")
#! Field("MGNT:DMPH:1:BTRMCTRL.FLNK",16777215,1,"MGNT:DMPH:1:BTRMCTRL.FLNK")
#! Link("MGNT:DMPH:1:BTRMCTRL.FLNK","MGNT:DMPH:1:BTRMSWITCH")
#! Field("MGNT:DMPH:1:BTRMCTRL.FFVL",16777215,1,"MGNT:DMPH:1:BTRMCTRL.FFVL")
#! Record("MGNT:DMPH:1:BTRMSWITCH",460,322,0,0,"MGNT:DMPH:1:BTRMSWITCH")
#! Field("MGNT:DMPH:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:DMPH:1:BTRMSWITCH.DOL1")
#! Link("MGNT:DMPH:1:BTRMSWITCH.DOL1","MGNT:DMPH:1:BTRMCTRL.FFVL")
#! Field("MGNT:DMPH:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:DMPH:1:BTRMSWITCH.LNK1")
#! Field("MGNT:DMPH:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:DMPH:1:BTRMSWITCH.FLNK")
#! Record("MGNT:DMPH:1:ALLBTRMSGO",240,96,0,0,"MGNT:DMPH:1:ALLBTRMSGO")
#! Field("MGNT:DMPH:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:DMPH:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:DMPH:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:DMPH:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:DMPH:1:ALLBTRMSGO.LNK1","MGNT:DMPH:1:ALLBTRMS.VAL")
#! Record("MGNT:DMPH:1:ALLBTRMS",540,102,0,0,"MGNT:DMPH:1:ALLBTRMS")
#! Field("MGNT:DMPH:1:ALLBTRMS.VAL",16777215,0,"MGNT:DMPH:1:ALLBTRMS.VAL")
#! Field("MGNT:DMPH:1:ALLBTRMS.FLNK",16777215,1,"MGNT:DMPH:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:DMPH:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:DMPH:1:LGPSSWITCH")
}

record(seq, "MGNT:DMPH:1:LGPSSWITCH") {
  field(DOL1, "MGNT:DMPH:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:DMPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPH:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPH:1:LGPSCTRL")
}

record(seq, "MGNT:DMPH:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:DMPH:1:ALLSTAR")
  field(LNK1, "MGNT:DMPH:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:DMPH:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPH:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPH:1:LGPSCTRL",20,10,0,0,"MGNT:DMPH:1:LGPSCTRL")
#! Field("MGNT:DMPH:1:LGPSCTRL.FLNK",16777215,1,"MGNT:DMPH:1:LGPSCTRL.FLNK")
#! Link("MGNT:DMPH:1:LGPSCTRL.FLNK","MGNT:DMPH:1:LGPSSWITCH")
#! Field("MGNT:DMPH:1:LGPSCTRL.FFVL",16777215,1,"MGNT:DMPH:1:LGPSCTRL.FFVL")
#! Record("MGNT:DMPH:1:LGPSSWITCH",460,322,0,0,"MGNT:DMPH:1:LGPSSWITCH")
#! Field("MGNT:DMPH:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:DMPH:1:LGPSSWITCH.DOL1")
#! Link("MGNT:DMPH:1:LGPSSWITCH.DOL1","MGNT:DMPH:1:LGPSCTRL.FFVL")
#! Field("MGNT:DMPH:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:DMPH:1:LGPSSWITCH.LNK1")
#! Field("MGNT:DMPH:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:DMPH:1:LGPSSWITCH.FLNK")
#! Record("MGNT:DMPH:1:ALLLGPSSGO",240,96,0,0,"MGNT:DMPH:1:ALLLGPSSGO")
#! Field("MGNT:DMPH:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:DMPH:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:DMPH:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:DMPH:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:DMPH:1:ALLLGPSSGO.LNK1","MGNT:DMPH:1:ALLLGPSS.VAL")
#! Record("MGNT:DMPH:1:ALLLGPSS",540,102,0,0,"MGNT:DMPH:1:ALLLGPSS")
#! Field("MGNT:DMPH:1:ALLLGPSS.VAL",16777215,0,"MGNT:DMPH:1:ALLLGPSS.VAL")
#! Field("MGNT:DMPH:1:ALLLGPSS.FLNK",16777215,1,"MGNT:DMPH:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:DMPH:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:DMPH:1:QUADSWITCH")
}

record(seq, "MGNT:DMPH:1:QUADSWITCH") {
  field(DOL1, "MGNT:DMPH:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:DMPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPH:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPH:1:QUADCTRL")
}

record(seq, "MGNT:DMPH:1:ALLQUADSGO") {
  field(DOL1, "MGNT:DMPH:1:ALLSTAR")
  field(LNK1, "MGNT:DMPH:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:DMPH:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPH:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPH:1:QUADCTRL",20,10,0,0,"MGNT:DMPH:1:QUADCTRL")
#! Field("MGNT:DMPH:1:QUADCTRL.FLNK",16777215,1,"MGNT:DMPH:1:QUADCTRL.FLNK")
#! Link("MGNT:DMPH:1:QUADCTRL.FLNK","MGNT:DMPH:1:QUADSWITCH")
#! Field("MGNT:DMPH:1:QUADCTRL.FFVL",16777215,1,"MGNT:DMPH:1:QUADCTRL.FFVL")
#! Record("MGNT:DMPH:1:QUADSWITCH",460,322,0,0,"MGNT:DMPH:1:QUADSWITCH")
#! Field("MGNT:DMPH:1:QUADSWITCH.DOL1",16777215,0,"MGNT:DMPH:1:QUADSWITCH.DOL1")
#! Link("MGNT:DMPH:1:QUADSWITCH.DOL1","MGNT:DMPH:1:QUADCTRL.FFVL")
#! Field("MGNT:DMPH:1:QUADSWITCH.LNK1",16777215,1,"MGNT:DMPH:1:QUADSWITCH.LNK1")
#! Field("MGNT:DMPH:1:QUADSWITCH.FLNK",16777215,1,"MGNT:DMPH:1:QUADSWITCH.FLNK")
#! Record("MGNT:DMPH:1:ALLQUADSGO",240,96,0,0,"MGNT:DMPH:1:ALLQUADSGO")
#! Field("MGNT:DMPH:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:DMPH:1:ALLQUADSGO.DOL1")
#! Field("MGNT:DMPH:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:DMPH:1:ALLQUADSGO.LNK1")
#! Link("MGNT:DMPH:1:ALLQUADSGO.LNK1","MGNT:DMPH:1:ALLQUADS.VAL")
#! Record("MGNT:DMPH:1:ALLQUADS",540,102,0,0,"MGNT:DMPH:1:ALLQUADS")
#! Field("MGNT:DMPH:1:ALLQUADS.VAL",16777215,0,"MGNT:DMPH:1:ALLQUADS.VAL")
#! Field("MGNT:DMPH:1:ALLQUADS.FLNK",16777215,1,"MGNT:DMPH:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:DMPH:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:DMPH:1:XCORSWITCH")
}

record(seq, "MGNT:DMPH:1:XCORSWITCH") {
  field(DOL1, "MGNT:DMPH:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:DMPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPH:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPH:1:XCORCTRL")
}

record(seq, "MGNT:DMPH:1:ALLXCORSGO") {
  field(DOL1, "MGNT:DMPH:1:ALLSTAR")
  field(LNK1, "MGNT:DMPH:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:DMPH:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPH:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPH:1:XCORCTRL",20,10,0,0,"MGNT:DMPH:1:XCORCTRL")
#! Field("MGNT:DMPH:1:XCORCTRL.FLNK",16777215,1,"MGNT:DMPH:1:XCORCTRL.FLNK")
#! Link("MGNT:DMPH:1:XCORCTRL.FLNK","MGNT:DMPH:1:XCORSWITCH")
#! Field("MGNT:DMPH:1:XCORCTRL.FFVL",16777215,1,"MGNT:DMPH:1:XCORCTRL.FFVL")
#! Record("MGNT:DMPH:1:XCORSWITCH",460,322,0,0,"MGNT:DMPH:1:XCORSWITCH")
#! Field("MGNT:DMPH:1:XCORSWITCH.DOL1",16777215,0,"MGNT:DMPH:1:XCORSWITCH.DOL1")
#! Link("MGNT:DMPH:1:XCORSWITCH.DOL1","MGNT:DMPH:1:XCORCTRL.FFVL")
#! Field("MGNT:DMPH:1:XCORSWITCH.LNK1",16777215,1,"MGNT:DMPH:1:XCORSWITCH.LNK1")
#! Field("MGNT:DMPH:1:XCORSWITCH.FLNK",16777215,1,"MGNT:DMPH:1:XCORSWITCH.FLNK")
#! Record("MGNT:DMPH:1:ALLXCORSGO",240,96,0,0,"MGNT:DMPH:1:ALLXCORSGO")
#! Field("MGNT:DMPH:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:DMPH:1:ALLXCORSGO.DOL1")
#! Field("MGNT:DMPH:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:DMPH:1:ALLXCORSGO.LNK1")
#! Link("MGNT:DMPH:1:ALLXCORSGO.LNK1","MGNT:DMPH:1:ALLXCORS.VAL")
#! Record("MGNT:DMPH:1:ALLXCORS",540,102,0,0,"MGNT:DMPH:1:ALLXCORS")
#! Field("MGNT:DMPH:1:ALLXCORS.VAL",16777215,0,"MGNT:DMPH:1:ALLXCORS.VAL")
#! Field("MGNT:DMPH:1:ALLXCORS.FLNK",16777215,1,"MGNT:DMPH:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:DMPH:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:DMPH:1:YCORSWITCH")
}

record(seq, "MGNT:DMPH:1:YCORSWITCH") {
  field(DOL1, "MGNT:DMPH:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:DMPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPH:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPH:1:YCORCTRL")
}

record(seq, "MGNT:DMPH:1:ALLYCORSGO") {
  field(DOL1, "MGNT:DMPH:1:ALLSTAR")
  field(LNK1, "MGNT:DMPH:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:DMPH:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPH:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPH:1:YCORCTRL",20,10,0,0,"MGNT:DMPH:1:YCORCTRL")
#! Field("MGNT:DMPH:1:YCORCTRL.FLNK",16777215,1,"MGNT:DMPH:1:YCORCTRL.FLNK")
#! Link("MGNT:DMPH:1:YCORCTRL.FLNK","MGNT:DMPH:1:YCORSWITCH")
#! Field("MGNT:DMPH:1:YCORCTRL.FFVL",16777215,1,"MGNT:DMPH:1:YCORCTRL.FFVL")
#! Record("MGNT:DMPH:1:YCORSWITCH",460,322,0,0,"MGNT:DMPH:1:YCORSWITCH")
#! Field("MGNT:DMPH:1:YCORSWITCH.DOL1",16777215,0,"MGNT:DMPH:1:YCORSWITCH.DOL1")
#! Link("MGNT:DMPH:1:YCORSWITCH.DOL1","MGNT:DMPH:1:YCORCTRL.FFVL")
#! Field("MGNT:DMPH:1:YCORSWITCH.LNK1",16777215,1,"MGNT:DMPH:1:YCORSWITCH.LNK1")
#! Field("MGNT:DMPH:1:YCORSWITCH.FLNK",16777215,1,"MGNT:DMPH:1:YCORSWITCH.FLNK")
#! Record("MGNT:DMPH:1:ALLYCORSGO",240,96,0,0,"MGNT:DMPH:1:ALLYCORSGO")
#! Field("MGNT:DMPH:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:DMPH:1:ALLYCORSGO.DOL1")
#! Field("MGNT:DMPH:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:DMPH:1:ALLYCORSGO.LNK1")
#! Link("MGNT:DMPH:1:ALLYCORSGO.LNK1","MGNT:DMPH:1:ALLYCORS.VAL")
#! Record("MGNT:DMPH:1:ALLYCORS",540,102,0,0,"MGNT:DMPH:1:ALLYCORS")
#! Field("MGNT:DMPH:1:ALLYCORS.VAL",16777215,0,"MGNT:DMPH:1:ALLYCORS.VAL")
#! Field("MGNT:DMPH:1:ALLYCORS.FLNK",16777215,1,"MGNT:DMPH:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:DMPH:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:DMPH:1:SOLNSWITCH")
}

record(seq, "MGNT:DMPH:1:SOLNSWITCH") {
  field(DOL1, "MGNT:DMPH:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:DMPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPH:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPH:1:SOLNCTRL")
}

record(seq, "MGNT:DMPH:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:DMPH:1:ALLSTAR")
  field(LNK1, "MGNT:DMPH:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:DMPH:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPH:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPH:1:SOLNCTRL",20,10,0,0,"MGNT:DMPH:1:SOLNCTRL")
#! Field("MGNT:DMPH:1:SOLNCTRL.FLNK",16777215,1,"MGNT:DMPH:1:SOLNCTRL.FLNK")
#! Link("MGNT:DMPH:1:SOLNCTRL.FLNK","MGNT:DMPH:1:SOLNSWITCH")
#! Field("MGNT:DMPH:1:SOLNCTRL.FFVL",16777215,1,"MGNT:DMPH:1:SOLNCTRL.FFVL")
#! Record("MGNT:DMPH:1:SOLNSWITCH",460,322,0,0,"MGNT:DMPH:1:SOLNSWITCH")
#! Field("MGNT:DMPH:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:DMPH:1:SOLNSWITCH.DOL1")
#! Link("MGNT:DMPH:1:SOLNSWITCH.DOL1","MGNT:DMPH:1:SOLNCTRL.FFVL")
#! Field("MGNT:DMPH:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:DMPH:1:SOLNSWITCH.LNK1")
#! Field("MGNT:DMPH:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:DMPH:1:SOLNSWITCH.FLNK")
#! Record("MGNT:DMPH:1:ALLSOLNSGO",240,96,0,0,"MGNT:DMPH:1:ALLSOLNSGO")
#! Field("MGNT:DMPH:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:DMPH:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:DMPH:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:DMPH:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:DMPH:1:ALLSOLNSGO.LNK1","MGNT:DMPH:1:ALLSOLNS.VAL")
#! Record("MGNT:DMPH:1:ALLSOLNS",540,102,0,0,"MGNT:DMPH:1:ALLSOLNS")
#! Field("MGNT:DMPH:1:ALLSOLNS.VAL",16777215,0,"MGNT:DMPH:1:ALLSOLNS.VAL")
#! Field("MGNT:DMPH:1:ALLSOLNS.FLNK",16777215,1,"MGNT:DMPH:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:DMPH:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:DMPH:1:KICKSWITCH")
}

record(seq, "MGNT:DMPH:1:KICKSWITCH") {
  field(DOL1, "MGNT:DMPH:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:DMPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPH:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPH:1:KICKCTRL")
}

record(seq, "MGNT:DMPH:1:ALLKICKSGO") {
  field(DOL1, "MGNT:DMPH:1:ALLSTAR")
  field(LNK1, "MGNT:DMPH:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:DMPH:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPH:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPH:1:KICKCTRL",20,10,0,0,"MGNT:DMPH:1:KICKCTRL")
#! Field("MGNT:DMPH:1:KICKCTRL.FLNK",16777215,1,"MGNT:DMPH:1:KICKCTRL.FLNK")
#! Link("MGNT:DMPH:1:KICKCTRL.FLNK","MGNT:DMPH:1:KICKSWITCH")
#! Field("MGNT:DMPH:1:KICKCTRL.FFVL",16777215,1,"MGNT:DMPH:1:KICKCTRL.FFVL")
#! Record("MGNT:DMPH:1:KICKSWITCH",460,322,0,0,"MGNT:DMPH:1:KICKSWITCH")
#! Field("MGNT:DMPH:1:KICKSWITCH.DOL1",16777215,0,"MGNT:DMPH:1:KICKSWITCH.DOL1")
#! Link("MGNT:DMPH:1:KICKSWITCH.DOL1","MGNT:DMPH:1:KICKCTRL.FFVL")
#! Field("MGNT:DMPH:1:KICKSWITCH.LNK1",16777215,1,"MGNT:DMPH:1:KICKSWITCH.LNK1")
#! Field("MGNT:DMPH:1:KICKSWITCH.FLNK",16777215,1,"MGNT:DMPH:1:KICKSWITCH.FLNK")
#! Record("MGNT:DMPH:1:ALLKICKSGO",240,96,0,0,"MGNT:DMPH:1:ALLKICKSGO")
#! Field("MGNT:DMPH:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:DMPH:1:ALLKICKSGO.DOL1")
#! Field("MGNT:DMPH:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:DMPH:1:ALLKICKSGO.LNK1")
#! Link("MGNT:DMPH:1:ALLKICKSGO.LNK1","MGNT:DMPH:1:ALLKICKS.VAL")
#! Record("MGNT:DMPH:1:ALLKICKS",540,102,0,0,"MGNT:DMPH:1:ALLKICKS")
#! Field("MGNT:DMPH:1:ALLKICKS.VAL",16777215,0,"MGNT:DMPH:1:ALLKICKS.VAL")
#! Field("MGNT:DMPH:1:ALLKICKS.FLNK",16777215,1,"MGNT:DMPH:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:DMPH:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:DMPH:1:SEXTSWITCH")
}

record(seq, "MGNT:DMPH:1:SEXTSWITCH") {
  field(DOL1, "MGNT:DMPH:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:DMPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPH:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPH:1:SEXTCTRL")
}

record(seq, "MGNT:DMPH:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:DMPH:1:ALLSTAR")
  field(LNK1, "MGNT:DMPH:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:DMPH:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPH:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPH:1:SEXTCTRL",20,10,0,0,"MGNT:DMPH:1:SEXTCTRL")
#! Field("MGNT:DMPH:1:SEXTCTRL.FLNK",16777215,1,"MGNT:DMPH:1:SEXTCTRL.FLNK")
#! Link("MGNT:DMPH:1:SEXTCTRL.FLNK","MGNT:DMPH:1:SEXTSWITCH")
#! Field("MGNT:DMPH:1:SEXTCTRL.FFVL",16777215,1,"MGNT:DMPH:1:SEXTCTRL.FFVL")
#! Record("MGNT:DMPH:1:SEXTSWITCH",460,322,0,0,"MGNT:DMPH:1:SEXTSWITCH")
#! Field("MGNT:DMPH:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:DMPH:1:SEXTSWITCH.DOL1")
#! Link("MGNT:DMPH:1:SEXTSWITCH.DOL1","MGNT:DMPH:1:SEXTCTRL.FFVL")
#! Field("MGNT:DMPH:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:DMPH:1:SEXTSWITCH.LNK1")
#! Field("MGNT:DMPH:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:DMPH:1:SEXTSWITCH.FLNK")
#! Record("MGNT:DMPH:1:ALLSEXTSGO",240,96,0,0,"MGNT:DMPH:1:ALLSEXTSGO")
#! Field("MGNT:DMPH:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:DMPH:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:DMPH:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:DMPH:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:DMPH:1:ALLSEXTSGO.LNK1","MGNT:DMPH:1:ALLSEXTS.VAL")
#! Record("MGNT:DMPH:1:ALLSEXTS",540,102,0,0,"MGNT:DMPH:1:ALLSEXTS")
#! Field("MGNT:DMPH:1:ALLSEXTS.VAL",16777215,0,"MGNT:DMPH:1:ALLSEXTS.VAL")
#! Field("MGNT:DMPH:1:ALLSEXTS.FLNK",16777215,1,"MGNT:DMPH:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:DMPS:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:DMPS:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:DMPS:1:CTRL CA PP")
  field(LNK2, "MGNT:DMPS:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:DMPS:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:DMPS:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:DMPS:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:DMPS:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:DMPS:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:DMPS:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:DMPS:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:DMPS:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:DMPS:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:DMPS:1:ALLSWITCH")
}

record(seq, "MGNT:DMPS:1:ALLSWITCH") {
  field(DOL1, "MGNT:DMPS:1:CTRL.FFVL")
  field(LNK1, "MGNT:DMPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPS:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPS:1:CTRL")
}

record(bo, "MGNT:DMPS:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:DMPS:1:ALLSTARGO")
}

record(fanout, "MGNT:DMPS:1:ALLSTARGO") {
  field(LNK1, "MGNT:DMPS:1:ALLBENDSGO")
  field(LNK2, "MGNT:DMPS:1:ALLBTRMSGO")
  field(LNK3, "MGNT:DMPS:1:ALLLGPSSGO")
  field(LNK4, "MGNT:DMPS:1:ALLQUADSGO")
  field(LNK5, "MGNT:DMPS:1:ALLXCORSGO")
  field(LNK6, "MGNT:DMPS:1:ALLYCORSGO")
  field(FLNK, "MGNT:DMPS:1:ALLSTARGO_2")
}
record(fanout, "MGNT:DMPS:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:DMPS:1:ALLSOLNSGO")
  field(LNK2, "MGNT:DMPS:1:ALLKICKSGO")
  field(LNK3, "MGNT:DMPS:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:DMPS:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:DMPS:1:BENDSWITCH")
}

record(seq, "MGNT:DMPS:1:BENDSWITCH") {
  field(DOL1, "MGNT:DMPS:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:DMPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPS:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPS:1:BENDCTRL")
}

record(seq, "MGNT:DMPS:1:ALLBENDSGO") {
  field(DOL1, "MGNT:DMPS:1:ALLSTAR")
  field(LNK1, "MGNT:DMPS:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:DMPS:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPS:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPS:1:BENDCTRL",20,10,0,0,"MGNT:DMPS:1:BENDCTRL")
#! Field("MGNT:DMPS:1:BENDCTRL.FLNK",16777215,1,"MGNT:DMPS:1:BENDCTRL.FLNK")
#! Link("MGNT:DMPS:1:BENDCTRL.FLNK","MGNT:DMPS:1:BENDSWITCH")
#! Field("MGNT:DMPS:1:BENDCTRL.FFVL",16777215,1,"MGNT:DMPS:1:BENDCTRL.FFVL")
#! Record("MGNT:DMPS:1:BENDSWITCH",460,322,0,0,"MGNT:DMPS:1:BENDSWITCH")
#! Field("MGNT:DMPS:1:BENDSWITCH.DOL1",16777215,0,"MGNT:DMPS:1:BENDSWITCH.DOL1")
#! Link("MGNT:DMPS:1:BENDSWITCH.DOL1","MGNT:DMPS:1:BENDCTRL.FFVL")
#! Field("MGNT:DMPS:1:BENDSWITCH.LNK1",16777215,1,"MGNT:DMPS:1:BENDSWITCH.LNK1")
#! Field("MGNT:DMPS:1:BENDSWITCH.FLNK",16777215,1,"MGNT:DMPS:1:BENDSWITCH.FLNK")
#! Record("MGNT:DMPS:1:ALLBENDSGO",240,96,0,0,"MGNT:DMPS:1:ALLBENDSGO")
#! Field("MGNT:DMPS:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:DMPS:1:ALLBENDSGO.DOL1")
#! Field("MGNT:DMPS:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:DMPS:1:ALLBENDSGO.LNK1")
#! Link("MGNT:DMPS:1:ALLBENDSGO.LNK1","MGNT:DMPS:1:ALLBENDS.VAL")
#! Record("MGNT:DMPS:1:ALLBENDS",540,102,0,0,"MGNT:DMPS:1:ALLBENDS")
#! Field("MGNT:DMPS:1:ALLBENDS.VAL",16777215,0,"MGNT:DMPS:1:ALLBENDS.VAL")
#! Field("MGNT:DMPS:1:ALLBENDS.FLNK",16777215,1,"MGNT:DMPS:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:DMPS:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:DMPS:1:BTRMSWITCH")
}

record(seq, "MGNT:DMPS:1:BTRMSWITCH") {
  field(DOL1, "MGNT:DMPS:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:DMPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPS:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPS:1:BTRMCTRL")
}

record(seq, "MGNT:DMPS:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:DMPS:1:ALLSTAR")
  field(LNK1, "MGNT:DMPS:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:DMPS:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPS:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPS:1:BTRMCTRL",20,10,0,0,"MGNT:DMPS:1:BTRMCTRL")
#! Field("MGNT:DMPS:1:BTRMCTRL.FLNK",16777215,1,"MGNT:DMPS:1:BTRMCTRL.FLNK")
#! Link("MGNT:DMPS:1:BTRMCTRL.FLNK","MGNT:DMPS:1:BTRMSWITCH")
#! Field("MGNT:DMPS:1:BTRMCTRL.FFVL",16777215,1,"MGNT:DMPS:1:BTRMCTRL.FFVL")
#! Record("MGNT:DMPS:1:BTRMSWITCH",460,322,0,0,"MGNT:DMPS:1:BTRMSWITCH")
#! Field("MGNT:DMPS:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:DMPS:1:BTRMSWITCH.DOL1")
#! Link("MGNT:DMPS:1:BTRMSWITCH.DOL1","MGNT:DMPS:1:BTRMCTRL.FFVL")
#! Field("MGNT:DMPS:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:DMPS:1:BTRMSWITCH.LNK1")
#! Field("MGNT:DMPS:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:DMPS:1:BTRMSWITCH.FLNK")
#! Record("MGNT:DMPS:1:ALLBTRMSGO",240,96,0,0,"MGNT:DMPS:1:ALLBTRMSGO")
#! Field("MGNT:DMPS:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:DMPS:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:DMPS:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:DMPS:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:DMPS:1:ALLBTRMSGO.LNK1","MGNT:DMPS:1:ALLBTRMS.VAL")
#! Record("MGNT:DMPS:1:ALLBTRMS",540,102,0,0,"MGNT:DMPS:1:ALLBTRMS")
#! Field("MGNT:DMPS:1:ALLBTRMS.VAL",16777215,0,"MGNT:DMPS:1:ALLBTRMS.VAL")
#! Field("MGNT:DMPS:1:ALLBTRMS.FLNK",16777215,1,"MGNT:DMPS:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:DMPS:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:DMPS:1:LGPSSWITCH")
}

record(seq, "MGNT:DMPS:1:LGPSSWITCH") {
  field(DOL1, "MGNT:DMPS:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:DMPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPS:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPS:1:LGPSCTRL")
}

record(seq, "MGNT:DMPS:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:DMPS:1:ALLSTAR")
  field(LNK1, "MGNT:DMPS:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:DMPS:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPS:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPS:1:LGPSCTRL",20,10,0,0,"MGNT:DMPS:1:LGPSCTRL")
#! Field("MGNT:DMPS:1:LGPSCTRL.FLNK",16777215,1,"MGNT:DMPS:1:LGPSCTRL.FLNK")
#! Link("MGNT:DMPS:1:LGPSCTRL.FLNK","MGNT:DMPS:1:LGPSSWITCH")
#! Field("MGNT:DMPS:1:LGPSCTRL.FFVL",16777215,1,"MGNT:DMPS:1:LGPSCTRL.FFVL")
#! Record("MGNT:DMPS:1:LGPSSWITCH",460,322,0,0,"MGNT:DMPS:1:LGPSSWITCH")
#! Field("MGNT:DMPS:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:DMPS:1:LGPSSWITCH.DOL1")
#! Link("MGNT:DMPS:1:LGPSSWITCH.DOL1","MGNT:DMPS:1:LGPSCTRL.FFVL")
#! Field("MGNT:DMPS:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:DMPS:1:LGPSSWITCH.LNK1")
#! Field("MGNT:DMPS:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:DMPS:1:LGPSSWITCH.FLNK")
#! Record("MGNT:DMPS:1:ALLLGPSSGO",240,96,0,0,"MGNT:DMPS:1:ALLLGPSSGO")
#! Field("MGNT:DMPS:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:DMPS:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:DMPS:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:DMPS:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:DMPS:1:ALLLGPSSGO.LNK1","MGNT:DMPS:1:ALLLGPSS.VAL")
#! Record("MGNT:DMPS:1:ALLLGPSS",540,102,0,0,"MGNT:DMPS:1:ALLLGPSS")
#! Field("MGNT:DMPS:1:ALLLGPSS.VAL",16777215,0,"MGNT:DMPS:1:ALLLGPSS.VAL")
#! Field("MGNT:DMPS:1:ALLLGPSS.FLNK",16777215,1,"MGNT:DMPS:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:DMPS:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:DMPS:1:QUADSWITCH")
}

record(seq, "MGNT:DMPS:1:QUADSWITCH") {
  field(DOL1, "MGNT:DMPS:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:DMPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPS:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPS:1:QUADCTRL")
}

record(seq, "MGNT:DMPS:1:ALLQUADSGO") {
  field(DOL1, "MGNT:DMPS:1:ALLSTAR")
  field(LNK1, "MGNT:DMPS:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:DMPS:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPS:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPS:1:QUADCTRL",20,10,0,0,"MGNT:DMPS:1:QUADCTRL")
#! Field("MGNT:DMPS:1:QUADCTRL.FLNK",16777215,1,"MGNT:DMPS:1:QUADCTRL.FLNK")
#! Link("MGNT:DMPS:1:QUADCTRL.FLNK","MGNT:DMPS:1:QUADSWITCH")
#! Field("MGNT:DMPS:1:QUADCTRL.FFVL",16777215,1,"MGNT:DMPS:1:QUADCTRL.FFVL")
#! Record("MGNT:DMPS:1:QUADSWITCH",460,322,0,0,"MGNT:DMPS:1:QUADSWITCH")
#! Field("MGNT:DMPS:1:QUADSWITCH.DOL1",16777215,0,"MGNT:DMPS:1:QUADSWITCH.DOL1")
#! Link("MGNT:DMPS:1:QUADSWITCH.DOL1","MGNT:DMPS:1:QUADCTRL.FFVL")
#! Field("MGNT:DMPS:1:QUADSWITCH.LNK1",16777215,1,"MGNT:DMPS:1:QUADSWITCH.LNK1")
#! Field("MGNT:DMPS:1:QUADSWITCH.FLNK",16777215,1,"MGNT:DMPS:1:QUADSWITCH.FLNK")
#! Record("MGNT:DMPS:1:ALLQUADSGO",240,96,0,0,"MGNT:DMPS:1:ALLQUADSGO")
#! Field("MGNT:DMPS:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:DMPS:1:ALLQUADSGO.DOL1")
#! Field("MGNT:DMPS:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:DMPS:1:ALLQUADSGO.LNK1")
#! Link("MGNT:DMPS:1:ALLQUADSGO.LNK1","MGNT:DMPS:1:ALLQUADS.VAL")
#! Record("MGNT:DMPS:1:ALLQUADS",540,102,0,0,"MGNT:DMPS:1:ALLQUADS")
#! Field("MGNT:DMPS:1:ALLQUADS.VAL",16777215,0,"MGNT:DMPS:1:ALLQUADS.VAL")
#! Field("MGNT:DMPS:1:ALLQUADS.FLNK",16777215,1,"MGNT:DMPS:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:DMPS:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:DMPS:1:XCORSWITCH")
}

record(seq, "MGNT:DMPS:1:XCORSWITCH") {
  field(DOL1, "MGNT:DMPS:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:DMPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPS:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPS:1:XCORCTRL")
}

record(seq, "MGNT:DMPS:1:ALLXCORSGO") {
  field(DOL1, "MGNT:DMPS:1:ALLSTAR")
  field(LNK1, "MGNT:DMPS:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:DMPS:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPS:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPS:1:XCORCTRL",20,10,0,0,"MGNT:DMPS:1:XCORCTRL")
#! Field("MGNT:DMPS:1:XCORCTRL.FLNK",16777215,1,"MGNT:DMPS:1:XCORCTRL.FLNK")
#! Link("MGNT:DMPS:1:XCORCTRL.FLNK","MGNT:DMPS:1:XCORSWITCH")
#! Field("MGNT:DMPS:1:XCORCTRL.FFVL",16777215,1,"MGNT:DMPS:1:XCORCTRL.FFVL")
#! Record("MGNT:DMPS:1:XCORSWITCH",460,322,0,0,"MGNT:DMPS:1:XCORSWITCH")
#! Field("MGNT:DMPS:1:XCORSWITCH.DOL1",16777215,0,"MGNT:DMPS:1:XCORSWITCH.DOL1")
#! Link("MGNT:DMPS:1:XCORSWITCH.DOL1","MGNT:DMPS:1:XCORCTRL.FFVL")
#! Field("MGNT:DMPS:1:XCORSWITCH.LNK1",16777215,1,"MGNT:DMPS:1:XCORSWITCH.LNK1")
#! Field("MGNT:DMPS:1:XCORSWITCH.FLNK",16777215,1,"MGNT:DMPS:1:XCORSWITCH.FLNK")
#! Record("MGNT:DMPS:1:ALLXCORSGO",240,96,0,0,"MGNT:DMPS:1:ALLXCORSGO")
#! Field("MGNT:DMPS:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:DMPS:1:ALLXCORSGO.DOL1")
#! Field("MGNT:DMPS:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:DMPS:1:ALLXCORSGO.LNK1")
#! Link("MGNT:DMPS:1:ALLXCORSGO.LNK1","MGNT:DMPS:1:ALLXCORS.VAL")
#! Record("MGNT:DMPS:1:ALLXCORS",540,102,0,0,"MGNT:DMPS:1:ALLXCORS")
#! Field("MGNT:DMPS:1:ALLXCORS.VAL",16777215,0,"MGNT:DMPS:1:ALLXCORS.VAL")
#! Field("MGNT:DMPS:1:ALLXCORS.FLNK",16777215,1,"MGNT:DMPS:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:DMPS:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:DMPS:1:YCORSWITCH")
}

record(seq, "MGNT:DMPS:1:YCORSWITCH") {
  field(DOL1, "MGNT:DMPS:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:DMPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPS:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPS:1:YCORCTRL")
}

record(seq, "MGNT:DMPS:1:ALLYCORSGO") {
  field(DOL1, "MGNT:DMPS:1:ALLSTAR")
  field(LNK1, "MGNT:DMPS:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:DMPS:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPS:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPS:1:YCORCTRL",20,10,0,0,"MGNT:DMPS:1:YCORCTRL")
#! Field("MGNT:DMPS:1:YCORCTRL.FLNK",16777215,1,"MGNT:DMPS:1:YCORCTRL.FLNK")
#! Link("MGNT:DMPS:1:YCORCTRL.FLNK","MGNT:DMPS:1:YCORSWITCH")
#! Field("MGNT:DMPS:1:YCORCTRL.FFVL",16777215,1,"MGNT:DMPS:1:YCORCTRL.FFVL")
#! Record("MGNT:DMPS:1:YCORSWITCH",460,322,0,0,"MGNT:DMPS:1:YCORSWITCH")
#! Field("MGNT:DMPS:1:YCORSWITCH.DOL1",16777215,0,"MGNT:DMPS:1:YCORSWITCH.DOL1")
#! Link("MGNT:DMPS:1:YCORSWITCH.DOL1","MGNT:DMPS:1:YCORCTRL.FFVL")
#! Field("MGNT:DMPS:1:YCORSWITCH.LNK1",16777215,1,"MGNT:DMPS:1:YCORSWITCH.LNK1")
#! Field("MGNT:DMPS:1:YCORSWITCH.FLNK",16777215,1,"MGNT:DMPS:1:YCORSWITCH.FLNK")
#! Record("MGNT:DMPS:1:ALLYCORSGO",240,96,0,0,"MGNT:DMPS:1:ALLYCORSGO")
#! Field("MGNT:DMPS:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:DMPS:1:ALLYCORSGO.DOL1")
#! Field("MGNT:DMPS:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:DMPS:1:ALLYCORSGO.LNK1")
#! Link("MGNT:DMPS:1:ALLYCORSGO.LNK1","MGNT:DMPS:1:ALLYCORS.VAL")
#! Record("MGNT:DMPS:1:ALLYCORS",540,102,0,0,"MGNT:DMPS:1:ALLYCORS")
#! Field("MGNT:DMPS:1:ALLYCORS.VAL",16777215,0,"MGNT:DMPS:1:ALLYCORS.VAL")
#! Field("MGNT:DMPS:1:ALLYCORS.FLNK",16777215,1,"MGNT:DMPS:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:DMPS:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:DMPS:1:SOLNSWITCH")
}

record(seq, "MGNT:DMPS:1:SOLNSWITCH") {
  field(DOL1, "MGNT:DMPS:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:DMPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPS:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPS:1:SOLNCTRL")
}

record(seq, "MGNT:DMPS:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:DMPS:1:ALLSTAR")
  field(LNK1, "MGNT:DMPS:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:DMPS:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPS:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPS:1:SOLNCTRL",20,10,0,0,"MGNT:DMPS:1:SOLNCTRL")
#! Field("MGNT:DMPS:1:SOLNCTRL.FLNK",16777215,1,"MGNT:DMPS:1:SOLNCTRL.FLNK")
#! Link("MGNT:DMPS:1:SOLNCTRL.FLNK","MGNT:DMPS:1:SOLNSWITCH")
#! Field("MGNT:DMPS:1:SOLNCTRL.FFVL",16777215,1,"MGNT:DMPS:1:SOLNCTRL.FFVL")
#! Record("MGNT:DMPS:1:SOLNSWITCH",460,322,0,0,"MGNT:DMPS:1:SOLNSWITCH")
#! Field("MGNT:DMPS:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:DMPS:1:SOLNSWITCH.DOL1")
#! Link("MGNT:DMPS:1:SOLNSWITCH.DOL1","MGNT:DMPS:1:SOLNCTRL.FFVL")
#! Field("MGNT:DMPS:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:DMPS:1:SOLNSWITCH.LNK1")
#! Field("MGNT:DMPS:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:DMPS:1:SOLNSWITCH.FLNK")
#! Record("MGNT:DMPS:1:ALLSOLNSGO",240,96,0,0,"MGNT:DMPS:1:ALLSOLNSGO")
#! Field("MGNT:DMPS:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:DMPS:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:DMPS:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:DMPS:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:DMPS:1:ALLSOLNSGO.LNK1","MGNT:DMPS:1:ALLSOLNS.VAL")
#! Record("MGNT:DMPS:1:ALLSOLNS",540,102,0,0,"MGNT:DMPS:1:ALLSOLNS")
#! Field("MGNT:DMPS:1:ALLSOLNS.VAL",16777215,0,"MGNT:DMPS:1:ALLSOLNS.VAL")
#! Field("MGNT:DMPS:1:ALLSOLNS.FLNK",16777215,1,"MGNT:DMPS:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:DMPS:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:DMPS:1:KICKSWITCH")
}

record(seq, "MGNT:DMPS:1:KICKSWITCH") {
  field(DOL1, "MGNT:DMPS:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:DMPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPS:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPS:1:KICKCTRL")
}

record(seq, "MGNT:DMPS:1:ALLKICKSGO") {
  field(DOL1, "MGNT:DMPS:1:ALLSTAR")
  field(LNK1, "MGNT:DMPS:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:DMPS:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPS:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPS:1:KICKCTRL",20,10,0,0,"MGNT:DMPS:1:KICKCTRL")
#! Field("MGNT:DMPS:1:KICKCTRL.FLNK",16777215,1,"MGNT:DMPS:1:KICKCTRL.FLNK")
#! Link("MGNT:DMPS:1:KICKCTRL.FLNK","MGNT:DMPS:1:KICKSWITCH")
#! Field("MGNT:DMPS:1:KICKCTRL.FFVL",16777215,1,"MGNT:DMPS:1:KICKCTRL.FFVL")
#! Record("MGNT:DMPS:1:KICKSWITCH",460,322,0,0,"MGNT:DMPS:1:KICKSWITCH")
#! Field("MGNT:DMPS:1:KICKSWITCH.DOL1",16777215,0,"MGNT:DMPS:1:KICKSWITCH.DOL1")
#! Link("MGNT:DMPS:1:KICKSWITCH.DOL1","MGNT:DMPS:1:KICKCTRL.FFVL")
#! Field("MGNT:DMPS:1:KICKSWITCH.LNK1",16777215,1,"MGNT:DMPS:1:KICKSWITCH.LNK1")
#! Field("MGNT:DMPS:1:KICKSWITCH.FLNK",16777215,1,"MGNT:DMPS:1:KICKSWITCH.FLNK")
#! Record("MGNT:DMPS:1:ALLKICKSGO",240,96,0,0,"MGNT:DMPS:1:ALLKICKSGO")
#! Field("MGNT:DMPS:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:DMPS:1:ALLKICKSGO.DOL1")
#! Field("MGNT:DMPS:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:DMPS:1:ALLKICKSGO.LNK1")
#! Link("MGNT:DMPS:1:ALLKICKSGO.LNK1","MGNT:DMPS:1:ALLKICKS.VAL")
#! Record("MGNT:DMPS:1:ALLKICKS",540,102,0,0,"MGNT:DMPS:1:ALLKICKS")
#! Field("MGNT:DMPS:1:ALLKICKS.VAL",16777215,0,"MGNT:DMPS:1:ALLKICKS.VAL")
#! Field("MGNT:DMPS:1:ALLKICKS.FLNK",16777215,1,"MGNT:DMPS:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:DMPS:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:DMPS:1:SEXTSWITCH")
}

record(seq, "MGNT:DMPS:1:SEXTSWITCH") {
  field(DOL1, "MGNT:DMPS:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:DMPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DMPS:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DMPS:1:SEXTCTRL")
}

record(seq, "MGNT:DMPS:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:DMPS:1:ALLSTAR")
  field(LNK1, "MGNT:DMPS:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:DMPS:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DMPS:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DMPS:1:SEXTCTRL",20,10,0,0,"MGNT:DMPS:1:SEXTCTRL")
#! Field("MGNT:DMPS:1:SEXTCTRL.FLNK",16777215,1,"MGNT:DMPS:1:SEXTCTRL.FLNK")
#! Link("MGNT:DMPS:1:SEXTCTRL.FLNK","MGNT:DMPS:1:SEXTSWITCH")
#! Field("MGNT:DMPS:1:SEXTCTRL.FFVL",16777215,1,"MGNT:DMPS:1:SEXTCTRL.FFVL")
#! Record("MGNT:DMPS:1:SEXTSWITCH",460,322,0,0,"MGNT:DMPS:1:SEXTSWITCH")
#! Field("MGNT:DMPS:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:DMPS:1:SEXTSWITCH.DOL1")
#! Link("MGNT:DMPS:1:SEXTSWITCH.DOL1","MGNT:DMPS:1:SEXTCTRL.FFVL")
#! Field("MGNT:DMPS:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:DMPS:1:SEXTSWITCH.LNK1")
#! Field("MGNT:DMPS:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:DMPS:1:SEXTSWITCH.FLNK")
#! Record("MGNT:DMPS:1:ALLSEXTSGO",240,96,0,0,"MGNT:DMPS:1:ALLSEXTSGO")
#! Field("MGNT:DMPS:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:DMPS:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:DMPS:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:DMPS:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:DMPS:1:ALLSEXTSGO.LNK1","MGNT:DMPS:1:ALLSEXTS.VAL")
#! Record("MGNT:DMPS:1:ALLSEXTS",540,102,0,0,"MGNT:DMPS:1:ALLSEXTS")
#! Field("MGNT:DMPS:1:ALLSEXTS.VAL",16777215,0,"MGNT:DMPS:1:ALLSEXTS.VAL")
#! Field("MGNT:DMPS:1:ALLSEXTS.FLNK",16777215,1,"MGNT:DMPS:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record (seq, "MGNT:DMPH:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:DMPH:1:ALLKICKSSEL"){
}
record (seq, "MGNT:DMPH:1:ALLSEXTSSEL"){
}

record(seq, "MGNT:DMPH:1:ALLBENDSSEL") {
  field(DOL1, "MGNT:DMPH:1:ALLBENDS")
  field(DOL2, "MGNT:DMPH:1:ALLBENDS")
  field(LNK1, "BEND:DMPH:395:SELECT PP NMS")
  field(LNK2, "BEND:DMPH:400:SELECT PP NMS")
}

record(seq, "MGNT:DMPH:1:ALLBTRMSSEL") {
  field(DOL1, "MGNT:DMPH:1:ALLBTRMS")
  field(DOL2, "MGNT:DMPH:1:ALLBTRMS")
  field(DOL3, "MGNT:DMPH:1:ALLBTRMS")
  field(DOL4, "MGNT:DMPH:1:ALLBTRMS")
  field(LNK1, "BTRM:LTUH:220:SELECT PP NMS")
  field(LNK2, "BTRM:LTUH:280:SELECT PP NMS")
  field(LNK3, "BTRM:LTUH:420:SELECT PP NMS")
  field(LNK4, "BTRM:LTUH:480:SELECT PP NMS")
}

record (seq, "MGNT:DMPH:1:ALLLGPSSSEL"){
}

record (seq, "MGNT:DMPH:1:ALLQUADSSEL"){
  field (DOL1, "MGNT:DMPH:1:ALLQUADS")
  field (DOL2, "MGNT:DMPH:1:ALLQUADS")
  field (DOL3, "MGNT:DMPH:1:ALLQUADS")
  field (LNK1, "QUAD:DMPH:300:SELECT PP NMS")
  field (LNK2, "QUAD:DMPH:380:SELECT PP NMS")
  field (LNK3, "QUAD:DMPH:500:SELECT PP NMS")
}

record (seq, "MGNT:DMPH:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:DMPH:1:ALLXCORS")
  field (DOL2, "MGNT:DMPH:1:ALLXCORS")
  field (DOL3, "MGNT:DMPH:1:ALLXCORS")
  field (LNK1, "XCOR:DMPH:298:SELECT PP NMS")
  field (LNK2, "XCOR:DMPH:392:SELECT PP NMS")
  field (LNK3, "XCOR:DMPH:602:SELECT PP NMS")
}

record (seq, "MGNT:DMPH:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:DMPH:1:ALLYCORS")
  field (DOL2, "MGNT:DMPH:1:ALLYCORS")
  field (DOL3, "MGNT:DMPH:1:ALLYCORS")
  field (LNK1, "YCOR:DMPH:201:SELECT PP NMS")
  field (LNK2, "YCOR:DMPH:391:SELECT PP NMS")
  field (LNK3, "YCOR:DMPH:440:SELECT PP NMS")
}

record (seq, "MGNT:DMPH:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:DMPH:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:DMPH:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:DMPH:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:DMPH:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:DMPH:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:DMPH:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:DMPH:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:DMPH:1:ALLFUNCGO2")
}
record (seq, "MGNT:DMPH:1:ALLFUNCGO2") {
  field (DESC, "Process CTRL func")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:DMPH:1:SOLNFUNCGO.PROC")
  field (LNK2, "MGNT:DMPH:1:KICKFUNCGO.PROC")
  field (LNK3, "MGNT:DMPH:1:SEXTFUNCGO.PROC")
  field (LNK4, "MGNT:DMPH:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:DMPH:1:CTRLCLEAR")
}
record (fanout, "MGNT:DMPH:1:SOLNFUNCGO") {
  field (DESC, "Process SOLN CTRL func")
  field (FLNK, "MGNT:DMPH:1:CTRLCLEAR")
}
record (fanout, "MGNT:DMPH:1:KICKFUNCGO") {
  field (DESC, "Process KICK CTRL func")
  field (FLNK, "MGNT:DMPH:1:CTRLCLEAR")
}
record (fanout, "MGNT:DMPH:1:SEXTFUNCGO") {
  field (DESC, "Process SEXT CTRL func")
  field (FLNK, "MGNT:DMPH:1:CTRLCLEAR")
}

record(fanout, "MGNT:DMPH:1:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(LNK1, "BEND:DMPH:395:ALLFUNCGO")
  field(LNK2, "BEND:DMPH:400:ALLFUNCGO")
  field(FLNK, "MGNT:DMPH:1:CTRLCLEAR")
}

record(fanout, "MGNT:DMPH:1:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(LNK1, "BTRM:LTUH:220:ALLFUNCGO")
  field(LNK2, "BTRM:LTUH:280:ALLFUNCGO")
  field(LNK3, "BTRM:LTUH:420:ALLFUNCGO")
  field(LNK4, "BTRM:LTUH:480:ALLFUNCGO")
  field(FLNK, "MGNT:DMPH:1:CTRLCLEAR")
}

record (fanout, "MGNT:DMPH:1:QUADFUNCGO") {
  field (DESC, "Process QUAD CTRL func")
  field (LNK1, "QUAD:DMPH:300:ALLFUNCGO")
  field (LNK2, "QUAD:DMPH:380:ALLFUNCGO")
  field (LNK3, "QUAD:DMPH:500:ALLFUNCGO")
  field (FLNK, "MGNT:DMPH:1:CTRLCLEAR")
}

record (fanout, "MGNT:DMPH:1:XCORFUNCGO") {
  field (DESC, "Process XCOR CTRL func")
  field (LNK1, "XCOR:DMPH:298:ALLFUNCGO")
  field (LNK2, "XCOR:DMPH:392:ALLFUNCGO")
  field (LNK3, "XCOR:DMPH:602:ALLFUNCGO")
  field (FLNK, "MGNT:DMPH:1:CTRLCLEAR")
}

record (fanout, "MGNT:DMPH:1:YCORFUNCGO") {
  field (DESC, "Process YCOR CTRL func")
  field (LNK1, "YCOR:DMPH:201:ALLFUNCGO")
  field (LNK2, "YCOR:DMPH:391:ALLFUNCGO")
  field (LNK3, "YCOR:DMPH:440:ALLFUNCGO")
  field (FLNK, "MGNT:DMPH:1:CTRLCLEAR")
}

record (fanout, "MGNT:DMPH:1:LGPSFUNCGO"){
  field (DESC, "Process LGPS CTRL func")
  field (FLNK, "MGNT:DMPH:1:CTRLCLEAR")
}


# End of file

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND
record(seq, "MGNT:DMPS:1:ALLSOLNSSEL"){
}
record(seq, "MGNT:DMPS:1:ALLKICKSSEL"){
}
record(seq, "MGNT:DMPS:1:ALLSEXTSSEL"){
}

record(seq, "MGNT:DMPS:1:ALLBENDSSEL") {
  field (DOL1, "MGNT:DMPS:1:ALLBENDS")
  field (DOL2, "MGNT:DMPS:1:ALLBENDS")
  field (LNK1, "BEND:DMPS:395:SELECT PP NMS")
  field (LNK2, "BEND:DMPS:400:SELECT PP NMS")
}

record(seq, "MGNT:DMPS:1:ALLBTRMSSEL") {
}

record(seq, "MGNT:DMPS:1:ALLLGPSSSEL"){
}

record(seq, "MGNT:DMPS:1:ALLQUADSSEL"){
  field (DOL1, "MGNT:DMPS:1:ALLQUADS")
  field (DOL2, "MGNT:DMPS:1:ALLQUADS")
  field(DOL3, "MGNT:DMPS:1:ALLQUADS")
  field(LNK1, "QUAD:DMPS:300:SELECT PP NMS")
  field(LNK2, "QUAD:DMPS:380:SELECT PP NMS")
  field(LNK3, "QUAD:DMPS:500:SELECT PP NMS")
}

record(seq, "MGNT:DMPS:1:ALLXCORSSEL"){
  field(DOL1, "MGNT:DMPS:1:ALLXCORS")
  field(DOL2, "MGNT:DMPS:1:ALLXCORS")
  field(DOL3, "MGNT:DMPS:1:ALLXCORS")
  field(LNK1, "XCOR:DMPS:298:SELECT PP NMS")
  field(LNK2, "XCOR:DMPS:392:SELECT PP NMS")
  field(LNK3, "XCOR:DMPS:602:SELECT PP NMS")
}

record(seq, "MGNT:DMPS:1:ALLYCORSSEL"){
  field(DOL1, "MGNT:DMPS:1:ALLYCORS")
  field(DOL2, "MGNT:DMPS:1:ALLYCORS")
  field(DOL3, "MGNT:DMPS:1:ALLYCORS")
  field(LNK1, "YCOR:DMPS:201:SELECT PP NMS")
  field(LNK2, "YCOR:DMPS:391:SELECT PP NMS")
  field(LNK3, "YCOR:DMPS:440:SELECT PP NMS")
}

record(seq, "MGNT:DMPS:1:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(LNK1, "MGNT:DMPS:1:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:DMPS:1:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:DMPS:1:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:DMPS:1:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:DMPS:1:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:DMPS:1:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:DMPS:1:LGPSFUNCGO.PROC")
  field(FLNK, "MGNT:DMPS:1:ALLFUNCGO2")
}
record(seq, "MGNT:DMPS:1:ALLFUNCGO2") {
  field(DESC, "Process CTRL func")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:DMPS:1:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:DMPS:1:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:DMPS:1:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:DMPS:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:DMPS:1:CTRLCLEAR")
}

record(fanout, "MGNT:DMPS:1:SOLNFUNCGO") {
  field(DESC, "Process SOLN CTRL func")
  field(FLNK, "MGNT:DMPS:1:CTRLCLEAR")
}
record(fanout, "MGNT:DMPS:1:KICKFUNCGO") {
  field(DESC, "Process KICK CTRL func")
  field(FLNK, "MGNT:DMPS:1:CTRLCLEAR")
}
record(fanout, "MGNT:DMPS:1:SEXTFUNCGO") {
  field(DESC, "Process SEXT CTRL func")
  field(FLNK, "MGNT:DMPS:1:CTRLCLEAR")
}

record(fanout, "MGNT:DMPS:1:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(LNK1, "BEND:DMPS:395:ALLFUNCGO")
  field(LNK2, "BEND:DMPS:400:ALLFUNCGO")
  field(FLNK, "MGNT:DMPS:1:CTRLCLEAR")
}

record(fanout, "MGNT:DMPS:1:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(FLNK, "MGNT:DMPS:1:CTRLCLEAR")
}

record(fanout, "MGNT:DMPS:1:QUADFUNCGO") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:DMPS:300:ALLFUNCGO")
  field(LNK2, "QUAD:DMPS:380:ALLFUNCGO")
  field(LNK3, "QUAD:DMPS:500:ALLFUNCGO")
  field(FLNK, "MGNT:DMPS:1:CTRLCLEAR")
}

record(fanout, "MGNT:DMPS:1:XCORFUNCGO") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:DMPS:298:ALLFUNCGO")
  field(LNK2, "XCOR:DMPS:392:ALLFUNCGO")
  field(LNK3, "XCOR:DMPS:602:ALLFUNCGO")
  field(FLNK, "MGNT:DMPS:1:CTRLCLEAR")
}

record(fanout, "MGNT:DMPS:1:YCORFUNCGO") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:DMPS:201:ALLFUNCGO")
  field(LNK2, "YCOR:DMPS:391:ALLFUNCGO")
  field(LNK3, "YCOR:DMPS:440:ALLFUNCGO")
  field(FLNK, "MGNT:DMPS:1:CTRLCLEAR")
}

record(fanout, "MGNT:DMPS:1:LGPSFUNCGO"){
  field(DESC, "Process LGPS CTRL func")
  field(FLNK, "MGNT:DMPS:1:CTRLCLEAR")
}


# End of file

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DMPH:395:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "BEND:DMPH:395:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DMPH:395:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DMPH:395:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DMPH:395:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DMPH:395:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DMPH:395:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DMPH:395:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DMPH:395:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DMPH:395:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DMPH:395:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DMPH:395:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DMPH:395:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DMPH:395:EDES.PROC PP")
    field(LNK2, "BEND:DMPH:395:EACT.PROC PP")
    field(LNK3, "BEND:DMPH:395:EERR.DISA PP")
    field(LNK4, "BEND:DMPH:395:ECON.PROC PP")
    field(LNK5, "BEND:DMPH:395:BMAGX.PROC PP")
    field(LNK6, "BEND:DMPH:395:BMAGY.PROC PP")
    field(LNK7, "BEND:DMPH:395:BLEM.PROC PP")
    field(LNK8, "BEND:DMPH:395:BMOD.PROC PP")
    field(LNK9, "BEND:DMPH:395:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DMPH:395:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DMPH:395:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DMPH:395:BMAX")
  field(DOL2, "BEND:DMPH:395:BMAX")
  field(DOL3, "BEND:DMPH:395:BMAX")
  field(DOL4, "BEND:DMPH:395:BMIN")
  field(DOL5, "BEND:DMPH:395:BMIN")
  field(DOL6, "BEND:DMPH:395:BMIN")
  field(LNK1, "BEND:DMPH:395:BMAGX.HOPR")
  field(LNK2, "BEND:DMPH:395:BMAGY.HOPR")
  field(LNK3, "BEND:DMPH:395:BLEM.HOPR")
  field(LNK4, "BEND:DMPH:395:BMAGX.LOPR PP")
  field(LNK5, "BEND:DMPH:395:BMAGY.LOPR PP")
  field(LNK6, "BEND:DMPH:395:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DMPH:395:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DMPH:395:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DMPH:395:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Gev/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DMPH:395:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Gev/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DMPH:395:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPH:395:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPH:395:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DMPH:395:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPH:395:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DMPH:395:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DMPH:395:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DMPH:395:EDES NPP MS")
  field(INPB, "BEND:DMPH:395:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DMPH:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "BEND:DMPH:400:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DMPH:400:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DMPH:400:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DMPH:400:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DMPH:400:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DMPH:400:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DMPH:400:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DMPH:400:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DMPH:400:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DMPH:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DMPH:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DMPH:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DMPH:400:EDES.PROC PP")
    field(LNK2, "BEND:DMPH:400:EACT.PROC PP")
    field(LNK3, "BEND:DMPH:400:EERR.DISA PP")
    field(LNK4, "BEND:DMPH:400:ECON.PROC PP")
    field(LNK5, "BEND:DMPH:400:BMAGX.PROC PP")
    field(LNK6, "BEND:DMPH:400:BMAGY.PROC PP")
    field(LNK7, "BEND:DMPH:400:BLEM.PROC PP")
    field(LNK8, "BEND:DMPH:400:BMOD.PROC PP")
    field(LNK9, "BEND:DMPH:400:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DMPH:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DMPH:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DMPH:400:BMAX")
  field(DOL2, "BEND:DMPH:400:BMAX")
  field(DOL3, "BEND:DMPH:400:BMAX")
  field(DOL4, "BEND:DMPH:400:BMIN")
  field(DOL5, "BEND:DMPH:400:BMIN")
  field(DOL6, "BEND:DMPH:400:BMIN")
  field(LNK1, "BEND:DMPH:400:BMAGX.HOPR")
  field(LNK2, "BEND:DMPH:400:BMAGY.HOPR")
  field(LNK3, "BEND:DMPH:400:BLEM.HOPR")
  field(LNK4, "BEND:DMPH:400:BMAGX.LOPR PP")
  field(LNK5, "BEND:DMPH:400:BMAGY.LOPR PP")
  field(LNK6, "BEND:DMPH:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DMPH:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DMPH:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DMPH:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DMPH:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DMPH:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPH:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPH:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DMPH:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPH:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DMPH:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DMPH:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DMPH:400:EDES NPP MS")
  field(INPB, "BEND:DMPH:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DMPH:300:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:DMPH:300:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DMPH:300:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DMPH:300:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DMPH:300:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DMPH:300:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DMPH:300:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DMPH:300:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DMPH:300:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DMPH:300:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DMPH:300:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DMPH:300:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DMPH:300:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DMPH:300:EDES.PROC PP")
    field(LNK2, "QUAD:DMPH:300:EACT.PROC PP")
    field(LNK3, "QUAD:DMPH:300:EERR.DISA PP")
    field(LNK4, "QUAD:DMPH:300:ECON.PROC PP")
    field(LNK5, "QUAD:DMPH:300:BMAGX.PROC PP")
    field(LNK6, "QUAD:DMPH:300:BMAGY.PROC PP")
    field(LNK7, "QUAD:DMPH:300:BLEM.PROC PP")
    field(LNK8, "QUAD:DMPH:300:BMOD.PROC PP")
    field(LNK9, "QUAD:DMPH:300:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DMPH:300:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DMPH:300:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DMPH:300:BMAX")
  field(DOL2, "QUAD:DMPH:300:BMAX")
  field(DOL3, "QUAD:DMPH:300:BMAX")
  field(DOL4, "QUAD:DMPH:300:BMIN")
  field(DOL5, "QUAD:DMPH:300:BMIN")
  field(DOL6, "QUAD:DMPH:300:BMIN")
  field(LNK1, "QUAD:DMPH:300:BMAGX.HOPR")
  field(LNK2, "QUAD:DMPH:300:BMAGY.HOPR")
  field(LNK3, "QUAD:DMPH:300:BLEM.HOPR")
  field(LNK4, "QUAD:DMPH:300:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DMPH:300:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DMPH:300:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPH:300:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPH:300:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DMPH:300:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DMPH:300:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DMPH:300:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPH:300:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPH:300:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DMPH:300:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPH:300:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DMPH:300:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DMPH:300:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DMPH:300:EDES NPP MS")
  field(INPB, "QUAD:DMPH:300:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DMPH:380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:DMPH:380:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DMPH:380:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DMPH:380:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DMPH:380:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DMPH:380:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DMPH:380:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DMPH:380:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DMPH:380:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DMPH:380:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DMPH:380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DMPH:380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DMPH:380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DMPH:380:EDES.PROC PP")
    field(LNK2, "QUAD:DMPH:380:EACT.PROC PP")
    field(LNK3, "QUAD:DMPH:380:EERR.DISA PP")
    field(LNK4, "QUAD:DMPH:380:ECON.PROC PP")
    field(LNK5, "QUAD:DMPH:380:BMAGX.PROC PP")
    field(LNK6, "QUAD:DMPH:380:BMAGY.PROC PP")
    field(LNK7, "QUAD:DMPH:380:BLEM.PROC PP")
    field(LNK8, "QUAD:DMPH:380:BMOD.PROC PP")
    field(LNK9, "QUAD:DMPH:380:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DMPH:380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DMPH:380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DMPH:380:BMAX")
  field(DOL2, "QUAD:DMPH:380:BMAX")
  field(DOL3, "QUAD:DMPH:380:BMAX")
  field(DOL4, "QUAD:DMPH:380:BMIN")
  field(DOL5, "QUAD:DMPH:380:BMIN")
  field(DOL6, "QUAD:DMPH:380:BMIN")
  field(LNK1, "QUAD:DMPH:380:BMAGX.HOPR")
  field(LNK2, "QUAD:DMPH:380:BMAGY.HOPR")
  field(LNK3, "QUAD:DMPH:380:BLEM.HOPR")
  field(LNK4, "QUAD:DMPH:380:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DMPH:380:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DMPH:380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPH:380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPH:380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DMPH:380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DMPH:380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DMPH:380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPH:380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPH:380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DMPH:380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPH:380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DMPH:380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DMPH:380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DMPH:380:EDES NPP MS")
  field(INPB, "QUAD:DMPH:380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DMPH:500:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:DMPH:500:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DMPH:500:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DMPH:500:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DMPH:500:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DMPH:500:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DMPH:500:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DMPH:500:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DMPH:500:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DMPH:500:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DMPH:500:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DMPH:500:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DMPH:500:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DMPH:500:EDES.PROC PP")
    field(LNK2, "QUAD:DMPH:500:EACT.PROC PP")
    field(LNK3, "QUAD:DMPH:500:EERR.DISA PP")
    field(LNK4, "QUAD:DMPH:500:ECON.PROC PP")
    field(LNK5, "QUAD:DMPH:500:BMAGX.PROC PP")
    field(LNK6, "QUAD:DMPH:500:BMAGY.PROC PP")
    field(LNK7, "QUAD:DMPH:500:BLEM.PROC PP")
    field(LNK8, "QUAD:DMPH:500:BMOD.PROC PP")
    field(LNK9, "QUAD:DMPH:500:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DMPH:500:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DMPH:500:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DMPH:500:BMAX")
  field(DOL2, "QUAD:DMPH:500:BMAX")
  field(DOL3, "QUAD:DMPH:500:BMAX")
  field(DOL4, "QUAD:DMPH:500:BMIN")
  field(DOL5, "QUAD:DMPH:500:BMIN")
  field(DOL6, "QUAD:DMPH:500:BMIN")
  field(LNK1, "QUAD:DMPH:500:BMAGX.HOPR")
  field(LNK2, "QUAD:DMPH:500:BMAGY.HOPR")
  field(LNK3, "QUAD:DMPH:500:BLEM.HOPR")
  field(LNK4, "QUAD:DMPH:500:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DMPH:500:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DMPH:500:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPH:500:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPH:500:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DMPH:500:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DMPH:500:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DMPH:500:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPH:500:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPH:500:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DMPH:500:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPH:500:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DMPH:500:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DMPH:500:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DMPH:500:EDES NPP MS")
  field(INPB, "QUAD:DMPH:500:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DMPH:298:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "XCOR:DMPH:298:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DMPH:298:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DMPH:298:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DMPH:298:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DMPH:298:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DMPH:298:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DMPH:298:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DMPH:298:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DMPH:298:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DMPH:298:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DMPH:298:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DMPH:298:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DMPH:298:EDES.PROC PP")
    field(LNK2, "XCOR:DMPH:298:EACT.PROC PP")
    field(LNK3, "XCOR:DMPH:298:EERR.DISA PP")
    field(LNK4, "XCOR:DMPH:298:ECON.PROC PP")
    field(LNK5, "XCOR:DMPH:298:BMAGX.PROC PP")
    field(LNK6, "XCOR:DMPH:298:BMAGY.PROC PP")
    field(LNK7, "XCOR:DMPH:298:BLEM.PROC PP")
    field(LNK8, "XCOR:DMPH:298:BMOD.PROC PP")
    field(LNK9, "XCOR:DMPH:298:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DMPH:298:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DMPH:298:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DMPH:298:BMAX")
  field(DOL2, "XCOR:DMPH:298:BMAX")
  field(DOL3, "XCOR:DMPH:298:BMAX")
  field(DOL4, "XCOR:DMPH:298:BMIN")
  field(DOL5, "XCOR:DMPH:298:BMIN")
  field(DOL6, "XCOR:DMPH:298:BMIN")
  field(LNK1, "XCOR:DMPH:298:BMAGX.HOPR")
  field(LNK2, "XCOR:DMPH:298:BMAGY.HOPR")
  field(LNK3, "XCOR:DMPH:298:BLEM.HOPR")
  field(LNK4, "XCOR:DMPH:298:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DMPH:298:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DMPH:298:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DMPH:298:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DMPH:298:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DMPH:298:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DMPH:298:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DMPH:298:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPH:298:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPH:298:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DMPH:298:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPH:298:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DMPH:298:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DMPH:298:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DMPH:298:EDES NPP MS")
  field(INPB, "XCOR:DMPH:298:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DMPH:392:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "XCOR:DMPH:392:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DMPH:392:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DMPH:392:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DMPH:392:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DMPH:392:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DMPH:392:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DMPH:392:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DMPH:392:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DMPH:392:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DMPH:392:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DMPH:392:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DMPH:392:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DMPH:392:EDES.PROC PP")
    field(LNK2, "XCOR:DMPH:392:EACT.PROC PP")
    field(LNK3, "XCOR:DMPH:392:EERR.DISA PP")
    field(LNK4, "XCOR:DMPH:392:ECON.PROC PP")
    field(LNK5, "XCOR:DMPH:392:BMAGX.PROC PP")
    field(LNK6, "XCOR:DMPH:392:BMAGY.PROC PP")
    field(LNK7, "XCOR:DMPH:392:BLEM.PROC PP")
    field(LNK8, "XCOR:DMPH:392:BMOD.PROC PP")
    field(LNK9, "XCOR:DMPH:392:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DMPH:392:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DMPH:392:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DMPH:392:BMAX")
  field(DOL2, "XCOR:DMPH:392:BMAX")
  field(DOL3, "XCOR:DMPH:392:BMAX")
  field(DOL4, "XCOR:DMPH:392:BMIN")
  field(DOL5, "XCOR:DMPH:392:BMIN")
  field(DOL6, "XCOR:DMPH:392:BMIN")
  field(LNK1, "XCOR:DMPH:392:BMAGX.HOPR")
  field(LNK2, "XCOR:DMPH:392:BMAGY.HOPR")
  field(LNK3, "XCOR:DMPH:392:BLEM.HOPR")
  field(LNK4, "XCOR:DMPH:392:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DMPH:392:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DMPH:392:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DMPH:392:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DMPH:392:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DMPH:392:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DMPH:392:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DMPH:392:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPH:392:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPH:392:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DMPH:392:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPH:392:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DMPH:392:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DMPH:392:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DMPH:392:EDES NPP MS")
  field(INPB, "XCOR:DMPH:392:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DMPH:602:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "XCOR:DMPH:602:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DMPH:602:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DMPH:602:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DMPH:602:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DMPH:602:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DMPH:602:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DMPH:602:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DMPH:602:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DMPH:602:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DMPH:602:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DMPH:602:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DMPH:602:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DMPH:602:EDES.PROC PP")
    field(LNK2, "XCOR:DMPH:602:EACT.PROC PP")
    field(LNK3, "XCOR:DMPH:602:EERR.DISA PP")
    field(LNK4, "XCOR:DMPH:602:ECON.PROC PP")
    field(LNK5, "XCOR:DMPH:602:BMAGX.PROC PP")
    field(LNK6, "XCOR:DMPH:602:BMAGY.PROC PP")
    field(LNK7, "XCOR:DMPH:602:BLEM.PROC PP")
    field(LNK8, "XCOR:DMPH:602:BMOD.PROC PP")
    field(LNK9, "XCOR:DMPH:602:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DMPH:602:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DMPH:602:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DMPH:602:BMAX")
  field(DOL2, "XCOR:DMPH:602:BMAX")
  field(DOL3, "XCOR:DMPH:602:BMAX")
  field(DOL4, "XCOR:DMPH:602:BMIN")
  field(DOL5, "XCOR:DMPH:602:BMIN")
  field(DOL6, "XCOR:DMPH:602:BMIN")
  field(LNK1, "XCOR:DMPH:602:BMAGX.HOPR")
  field(LNK2, "XCOR:DMPH:602:BMAGY.HOPR")
  field(LNK3, "XCOR:DMPH:602:BLEM.HOPR")
  field(LNK4, "XCOR:DMPH:602:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DMPH:602:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DMPH:602:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DMPH:602:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DMPH:602:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DMPH:602:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DMPH:602:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DMPH:602:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPH:602:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPH:602:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DMPH:602:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPH:602:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DMPH:602:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DMPH:602:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DMPH:602:EDES NPP MS")
  field(INPB, "XCOR:DMPH:602:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DMPH:201:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "YCOR:DMPH:201:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DMPH:201:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DMPH:201:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DMPH:201:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DMPH:201:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DMPH:201:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DMPH:201:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DMPH:201:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DMPH:201:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DMPH:201:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DMPH:201:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DMPH:201:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DMPH:201:EDES.PROC PP")
    field(LNK2, "YCOR:DMPH:201:EACT.PROC PP")
    field(LNK3, "YCOR:DMPH:201:EERR.DISA PP")
    field(LNK4, "YCOR:DMPH:201:ECON.PROC PP")
    field(LNK5, "YCOR:DMPH:201:BMAGX.PROC PP")
    field(LNK6, "YCOR:DMPH:201:BMAGY.PROC PP")
    field(LNK7, "YCOR:DMPH:201:BLEM.PROC PP")
    field(LNK8, "YCOR:DMPH:201:BMOD.PROC PP")
    field(LNK9, "YCOR:DMPH:201:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DMPH:201:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DMPH:201:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DMPH:201:BMAX")
  field(DOL2, "YCOR:DMPH:201:BMAX")
  field(DOL3, "YCOR:DMPH:201:BMAX")
  field(DOL4, "YCOR:DMPH:201:BMIN")
  field(DOL5, "YCOR:DMPH:201:BMIN")
  field(DOL6, "YCOR:DMPH:201:BMIN")
  field(LNK1, "YCOR:DMPH:201:BMAGX.HOPR")
  field(LNK2, "YCOR:DMPH:201:BMAGY.HOPR")
  field(LNK3, "YCOR:DMPH:201:BLEM.HOPR")
  field(LNK4, "YCOR:DMPH:201:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DMPH:201:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DMPH:201:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DMPH:201:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DMPH:201:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DMPH:201:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DMPH:201:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DMPH:201:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPH:201:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPH:201:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DMPH:201:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPH:201:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DMPH:201:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DMPH:201:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DMPH:201:EDES NPP MS")
  field(INPB, "YCOR:DMPH:201:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DMPH:391:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "YCOR:DMPH:391:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DMPH:391:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DMPH:391:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DMPH:391:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DMPH:391:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DMPH:391:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DMPH:391:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DMPH:391:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DMPH:391:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DMPH:391:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DMPH:391:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DMPH:391:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DMPH:391:EDES.PROC PP")
    field(LNK2, "YCOR:DMPH:391:EACT.PROC PP")
    field(LNK3, "YCOR:DMPH:391:EERR.DISA PP")
    field(LNK4, "YCOR:DMPH:391:ECON.PROC PP")
    field(LNK5, "YCOR:DMPH:391:BMAGX.PROC PP")
    field(LNK6, "YCOR:DMPH:391:BMAGY.PROC PP")
    field(LNK7, "YCOR:DMPH:391:BLEM.PROC PP")
    field(LNK8, "YCOR:DMPH:391:BMOD.PROC PP")
    field(LNK9, "YCOR:DMPH:391:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DMPH:391:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DMPH:391:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DMPH:391:BMAX")
  field(DOL2, "YCOR:DMPH:391:BMAX")
  field(DOL3, "YCOR:DMPH:391:BMAX")
  field(DOL4, "YCOR:DMPH:391:BMIN")
  field(DOL5, "YCOR:DMPH:391:BMIN")
  field(DOL6, "YCOR:DMPH:391:BMIN")
  field(LNK1, "YCOR:DMPH:391:BMAGX.HOPR")
  field(LNK2, "YCOR:DMPH:391:BMAGY.HOPR")
  field(LNK3, "YCOR:DMPH:391:BLEM.HOPR")
  field(LNK4, "YCOR:DMPH:391:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DMPH:391:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DMPH:391:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DMPH:391:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DMPH:391:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DMPH:391:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DMPH:391:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DMPH:391:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPH:391:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPH:391:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DMPH:391:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPH:391:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DMPH:391:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DMPH:391:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DMPH:391:EDES NPP MS")
  field(INPB, "YCOR:DMPH:391:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DMPH:440:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "YCOR:DMPH:440:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DMPH:440:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DMPH:440:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DMPH:440:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DMPH:440:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DMPH:440:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DMPH:440:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DMPH:440:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DMPH:440:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DMPH:440:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DMPH:440:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DMPH:440:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DMPH:440:EDES.PROC PP")
    field(LNK2, "YCOR:DMPH:440:EACT.PROC PP")
    field(LNK3, "YCOR:DMPH:440:EERR.DISA PP")
    field(LNK4, "YCOR:DMPH:440:ECON.PROC PP")
    field(LNK5, "YCOR:DMPH:440:BMAGX.PROC PP")
    field(LNK6, "YCOR:DMPH:440:BMAGY.PROC PP")
    field(LNK7, "YCOR:DMPH:440:BLEM.PROC PP")
    field(LNK8, "YCOR:DMPH:440:BMOD.PROC PP")
    field(LNK9, "YCOR:DMPH:440:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DMPH:440:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DMPH:440:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DMPH:440:BMAX")
  field(DOL2, "YCOR:DMPH:440:BMAX")
  field(DOL3, "YCOR:DMPH:440:BMAX")
  field(DOL4, "YCOR:DMPH:440:BMIN")
  field(DOL5, "YCOR:DMPH:440:BMIN")
  field(DOL6, "YCOR:DMPH:440:BMIN")
  field(LNK1, "YCOR:DMPH:440:BMAGX.HOPR")
  field(LNK2, "YCOR:DMPH:440:BMAGY.HOPR")
  field(LNK3, "YCOR:DMPH:440:BLEM.HOPR")
  field(LNK4, "YCOR:DMPH:440:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DMPH:440:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DMPH:440:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DMPH:440:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DMPH:440:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DMPH:440:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DMPH:440:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DMPH:440:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPH:440:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPH:440:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DMPH:440:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPH:440:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DMPH:440:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DMPH:440:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DMPH:440:EDES NPP MS")
  field(INPB, "YCOR:DMPH:440:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DMPS:395:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPS:1:CTRL.RVAL")
  field(LNK1, "BEND:DMPS:395:FUNC CA PP")
  field(DOL2, "MGNT:DMPS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DMPS:395:FUNC CA PP")
  field(DOL3, "MGNT:DMPS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DMPS:395:FUNC CA PP")
  field(DOL4, "MGNT:DMPS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DMPS:395:FUNC CA PP")
  field(DOL5, "MGNT:DMPS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DMPS:395:FUNC CA PP")
  field(DOL6, "MGNT:DMPS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DMPS:395:FUNC CA PP")
  field(DOL7, "MGNT:DMPS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DMPS:395:FUNC CA PP")
  field(DOL8, "MGNT:DMPS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DMPS:395:FUNC CA PP")
  field(DOL9, "MGNT:DMPS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DMPS:395:FUNC CA PP")
  field(DOLA, "MGNT:DMPS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DMPS:395:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DMPS:395:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DMPS:395:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DMPS:395:EDES.PROC PP")
    field(LNK2, "BEND:DMPS:395:EACT.PROC PP")
    field(LNK3, "BEND:DMPS:395:EERR.DISA PP")
    field(LNK4, "BEND:DMPS:395:ECON.PROC PP")
    field(LNK5, "BEND:DMPS:395:BMAGX.PROC PP")
    field(LNK6, "BEND:DMPS:395:BMAGY.PROC PP")
    field(LNK7, "BEND:DMPS:395:BLEM.PROC PP")
    field(LNK8, "BEND:DMPS:395:BMOD.PROC PP")
    field(LNK9, "BEND:DMPS:395:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DMPS:395:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DMPS:395:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DMPS:395:BMAX")
  field(DOL2, "BEND:DMPS:395:BMAX")
  field(DOL3, "BEND:DMPS:395:BMAX")
  field(DOL4, "BEND:DMPS:395:BMIN")
  field(DOL5, "BEND:DMPS:395:BMIN")
  field(DOL6, "BEND:DMPS:395:BMIN")
  field(LNK1, "BEND:DMPS:395:BMAGX.HOPR")
  field(LNK2, "BEND:DMPS:395:BMAGY.HOPR")
  field(LNK3, "BEND:DMPS:395:BLEM.HOPR")
  field(LNK4, "BEND:DMPS:395:BMAGX.LOPR PP")
  field(LNK5, "BEND:DMPS:395:BMAGY.LOPR PP")
  field(LNK6, "BEND:DMPS:395:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DMPS:395:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DMPS:395:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DMPS:395:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/C")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DMPS:395:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/C")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DMPS:395:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPS:395:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPS:395:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DMPS:395:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPS:395:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DMPS:395:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DMPS:395:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DMPS:395:EDES NPP MS")
  field(INPB, "BEND:DMPS:395:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DMPS:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPS:1:CTRL.RVAL")
  field(LNK1, "BEND:DMPS:400:FUNC CA PP")
  field(DOL2, "MGNT:DMPS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DMPS:400:FUNC CA PP")
  field(DOL3, "MGNT:DMPS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DMPS:400:FUNC CA PP")
  field(DOL4, "MGNT:DMPS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DMPS:400:FUNC CA PP")
  field(DOL5, "MGNT:DMPS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DMPS:400:FUNC CA PP")
  field(DOL6, "MGNT:DMPS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DMPS:400:FUNC CA PP")
  field(DOL7, "MGNT:DMPS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DMPS:400:FUNC CA PP")
  field(DOL8, "MGNT:DMPS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DMPS:400:FUNC CA PP")
  field(DOL9, "MGNT:DMPS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DMPS:400:FUNC CA PP")
  field(DOLA, "MGNT:DMPS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DMPS:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DMPS:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DMPS:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DMPS:400:EDES.PROC PP")
    field(LNK2, "BEND:DMPS:400:EACT.PROC PP")
    field(LNK3, "BEND:DMPS:400:EERR.DISA PP")
    field(LNK4, "BEND:DMPS:400:ECON.PROC PP")
    field(LNK5, "BEND:DMPS:400:BMAGX.PROC PP")
    field(LNK6, "BEND:DMPS:400:BMAGY.PROC PP")
    field(LNK7, "BEND:DMPS:400:BLEM.PROC PP")
    field(LNK8, "BEND:DMPS:400:BMOD.PROC PP")
    field(LNK9, "BEND:DMPS:400:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DMPS:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DMPS:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DMPS:400:BMAX")
  field(DOL2, "BEND:DMPS:400:BMAX")
  field(DOL3, "BEND:DMPS:400:BMAX")
  field(DOL4, "BEND:DMPS:400:BMIN")
  field(DOL5, "BEND:DMPS:400:BMIN")
  field(DOL6, "BEND:DMPS:400:BMIN")
  field(LNK1, "BEND:DMPS:400:BMAGX.HOPR")
  field(LNK2, "BEND:DMPS:400:BMAGY.HOPR")
  field(LNK3, "BEND:DMPS:400:BLEM.HOPR")
  field(LNK4, "BEND:DMPS:400:BMAGX.LOPR PP")
  field(LNK5, "BEND:DMPS:400:BMAGY.LOPR PP")
  field(LNK6, "BEND:DMPS:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DMPS:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DMPS:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DMPS:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/C")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DMPS:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/C")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DMPS:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPS:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPS:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DMPS:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPS:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DMPS:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DMPS:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DMPS:400:EDES NPP MS")
  field(INPB, "BEND:DMPS:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DMPS:300:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPS:1:CTRL.RVAL")
  field(LNK1, "QUAD:DMPS:300:FUNC CA PP")
  field(DOL2, "MGNT:DMPS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DMPS:300:FUNC CA PP")
  field(DOL3, "MGNT:DMPS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DMPS:300:FUNC CA PP")
  field(DOL4, "MGNT:DMPS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DMPS:300:FUNC CA PP")
  field(DOL5, "MGNT:DMPS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DMPS:300:FUNC CA PP")
  field(DOL6, "MGNT:DMPS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DMPS:300:FUNC CA PP")
  field(DOL7, "MGNT:DMPS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DMPS:300:FUNC CA PP")
  field(DOL8, "MGNT:DMPS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DMPS:300:FUNC CA PP")
  field(DOL9, "MGNT:DMPS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DMPS:300:FUNC CA PP")
  field(DOLA, "MGNT:DMPS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DMPS:300:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DMPS:300:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DMPS:300:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DMPS:300:EDES.PROC PP")
    field(LNK2, "QUAD:DMPS:300:EACT.PROC PP")
    field(LNK3, "QUAD:DMPS:300:EERR.DISA PP")
    field(LNK4, "QUAD:DMPS:300:ECON.PROC PP")
    field(LNK5, "QUAD:DMPS:300:BMAGX.PROC PP")
    field(LNK6, "QUAD:DMPS:300:BMAGY.PROC PP")
    field(LNK7, "QUAD:DMPS:300:BLEM.PROC PP")
    field(LNK8, "QUAD:DMPS:300:BMOD.PROC PP")
    field(LNK9, "QUAD:DMPS:300:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DMPS:300:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DMPS:300:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DMPS:300:BMAX")
  field(DOL2, "QUAD:DMPS:300:BMAX")
  field(DOL3, "QUAD:DMPS:300:BMAX")
  field(DOL4, "QUAD:DMPS:300:BMIN")
  field(DOL5, "QUAD:DMPS:300:BMIN")
  field(DOL6, "QUAD:DMPS:300:BMIN")
  field(LNK1, "QUAD:DMPS:300:BMAGX.HOPR")
  field(LNK2, "QUAD:DMPS:300:BMAGY.HOPR")
  field(LNK3, "QUAD:DMPS:300:BLEM.HOPR")
  field(LNK4, "QUAD:DMPS:300:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DMPS:300:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DMPS:300:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPS:300:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPS:300:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DMPS:300:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DMPS:300:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DMPS:300:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPS:300:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPS:300:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DMPS:300:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPS:300:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DMPS:300:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DMPS:300:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DMPS:300:EDES NPP MS")
  field(INPB, "QUAD:DMPS:300:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DMPS:380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPS:1:CTRL.RVAL")
  field(LNK1, "QUAD:DMPS:380:FUNC CA PP")
  field(DOL2, "MGNT:DMPS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DMPS:380:FUNC CA PP")
  field(DOL3, "MGNT:DMPS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DMPS:380:FUNC CA PP")
  field(DOL4, "MGNT:DMPS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DMPS:380:FUNC CA PP")
  field(DOL5, "MGNT:DMPS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DMPS:380:FUNC CA PP")
  field(DOL6, "MGNT:DMPS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DMPS:380:FUNC CA PP")
  field(DOL7, "MGNT:DMPS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DMPS:380:FUNC CA PP")
  field(DOL8, "MGNT:DMPS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DMPS:380:FUNC CA PP")
  field(DOL9, "MGNT:DMPS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DMPS:380:FUNC CA PP")
  field(DOLA, "MGNT:DMPS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DMPS:380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DMPS:380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DMPS:380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DMPS:380:EDES.PROC PP")
    field(LNK2, "QUAD:DMPS:380:EACT.PROC PP")
    field(LNK3, "QUAD:DMPS:380:EERR.DISA PP")
    field(LNK4, "QUAD:DMPS:380:ECON.PROC PP")
    field(LNK5, "QUAD:DMPS:380:BMAGX.PROC PP")
    field(LNK6, "QUAD:DMPS:380:BMAGY.PROC PP")
    field(LNK7, "QUAD:DMPS:380:BLEM.PROC PP")
    field(LNK8, "QUAD:DMPS:380:BMOD.PROC PP")
    field(LNK9, "QUAD:DMPS:380:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DMPS:380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DMPS:380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DMPS:380:BMAX")
  field(DOL2, "QUAD:DMPS:380:BMAX")
  field(DOL3, "QUAD:DMPS:380:BMAX")
  field(DOL4, "QUAD:DMPS:380:BMIN")
  field(DOL5, "QUAD:DMPS:380:BMIN")
  field(DOL6, "QUAD:DMPS:380:BMIN")
  field(LNK1, "QUAD:DMPS:380:BMAGX.HOPR")
  field(LNK2, "QUAD:DMPS:380:BMAGY.HOPR")
  field(LNK3, "QUAD:DMPS:380:BLEM.HOPR")
  field(LNK4, "QUAD:DMPS:380:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DMPS:380:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DMPS:380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPS:380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPS:380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DMPS:380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DMPS:380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DMPS:380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPS:380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPS:380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DMPS:380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPS:380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DMPS:380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DMPS:380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DMPS:380:EDES NPP MS")
  field(INPB, "QUAD:DMPS:380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DMPS:500:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPS:1:CTRL.RVAL")
  field(LNK1, "QUAD:DMPS:500:FUNC CA PP")
  field(DOL2, "MGNT:DMPS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DMPS:500:FUNC CA PP")
  field(DOL3, "MGNT:DMPS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DMPS:500:FUNC CA PP")
  field(DOL4, "MGNT:DMPS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DMPS:500:FUNC CA PP")
  field(DOL5, "MGNT:DMPS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DMPS:500:FUNC CA PP")
  field(DOL6, "MGNT:DMPS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DMPS:500:FUNC CA PP")
  field(DOL7, "MGNT:DMPS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DMPS:500:FUNC CA PP")
  field(DOL8, "MGNT:DMPS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DMPS:500:FUNC CA PP")
  field(DOL9, "MGNT:DMPS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DMPS:500:FUNC CA PP")
  field(DOLA, "MGNT:DMPS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DMPS:500:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DMPS:500:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DMPS:500:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DMPS:500:EDES.PROC PP")
    field(LNK2, "QUAD:DMPS:500:EACT.PROC PP")
    field(LNK3, "QUAD:DMPS:500:EERR.DISA PP")
    field(LNK4, "QUAD:DMPS:500:ECON.PROC PP")
    field(LNK5, "QUAD:DMPS:500:BMAGX.PROC PP")
    field(LNK6, "QUAD:DMPS:500:BMAGY.PROC PP")
    field(LNK7, "QUAD:DMPS:500:BLEM.PROC PP")
    field(LNK8, "QUAD:DMPS:500:BMOD.PROC PP")
    field(LNK9, "QUAD:DMPS:500:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DMPS:500:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DMPS:500:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DMPS:500:BMAX")
  field(DOL2, "QUAD:DMPS:500:BMAX")
  field(DOL3, "QUAD:DMPS:500:BMAX")
  field(DOL4, "QUAD:DMPS:500:BMIN")
  field(DOL5, "QUAD:DMPS:500:BMIN")
  field(DOL6, "QUAD:DMPS:500:BMIN")
  field(LNK1, "QUAD:DMPS:500:BMAGX.HOPR")
  field(LNK2, "QUAD:DMPS:500:BMAGY.HOPR")
  field(LNK3, "QUAD:DMPS:500:BLEM.HOPR")
  field(LNK4, "QUAD:DMPS:500:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DMPS:500:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DMPS:500:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPS:500:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPS:500:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DMPS:500:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DMPS:500:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DMPS:500:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPS:500:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPS:500:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DMPS:500:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPS:500:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DMPS:500:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DMPS:500:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DMPS:500:EDES NPP MS")
  field(INPB, "QUAD:DMPS:500:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DMPS:298:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPS:1:CTRL.RVAL")
  field(LNK1, "XCOR:DMPS:298:FUNC CA PP")
  field(DOL2, "MGNT:DMPS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DMPS:298:FUNC CA PP")
  field(DOL3, "MGNT:DMPS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DMPS:298:FUNC CA PP")
  field(DOL4, "MGNT:DMPS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DMPS:298:FUNC CA PP")
  field(DOL5, "MGNT:DMPS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DMPS:298:FUNC CA PP")
  field(DOL6, "MGNT:DMPS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DMPS:298:FUNC CA PP")
  field(DOL7, "MGNT:DMPS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DMPS:298:FUNC CA PP")
  field(DOL8, "MGNT:DMPS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DMPS:298:FUNC CA PP")
  field(DOL9, "MGNT:DMPS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DMPS:298:FUNC CA PP")
  field(DOLA, "MGNT:DMPS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DMPS:298:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DMPS:298:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DMPS:298:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DMPS:298:EDES.PROC PP")
    field(LNK2, "XCOR:DMPS:298:EACT.PROC PP")
    field(LNK3, "XCOR:DMPS:298:EERR.DISA PP")
    field(LNK4, "XCOR:DMPS:298:ECON.PROC PP")
    field(LNK5, "XCOR:DMPS:298:BMAGX.PROC PP")
    field(LNK6, "XCOR:DMPS:298:BMAGY.PROC PP")
    field(LNK7, "XCOR:DMPS:298:BLEM.PROC PP")
    field(LNK8, "XCOR:DMPS:298:BMOD.PROC PP")
    field(LNK9, "XCOR:DMPS:298:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DMPS:298:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DMPS:298:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DMPS:298:BMAX")
  field(DOL2, "XCOR:DMPS:298:BMAX")
  field(DOL3, "XCOR:DMPS:298:BMAX")
  field(DOL4, "XCOR:DMPS:298:BMIN")
  field(DOL5, "XCOR:DMPS:298:BMIN")
  field(DOL6, "XCOR:DMPS:298:BMIN")
  field(LNK1, "XCOR:DMPS:298:BMAGX.HOPR")
  field(LNK2, "XCOR:DMPS:298:BMAGY.HOPR")
  field(LNK3, "XCOR:DMPS:298:BLEM.HOPR")
  field(LNK4, "XCOR:DMPS:298:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DMPS:298:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DMPS:298:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DMPS:298:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DMPS:298:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DMPS:298:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DMPS:298:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DMPS:298:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPS:298:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPS:298:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DMPS:298:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPS:298:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DMPS:298:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DMPS:298:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DMPS:298:EDES NPP MS")
  field(INPB, "XCOR:DMPS:298:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DMPS:392:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPS:1:CTRL.RVAL")
  field(LNK1, "XCOR:DMPS:392:FUNC CA PP")
  field(DOL2, "MGNT:DMPS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DMPS:392:FUNC CA PP")
  field(DOL3, "MGNT:DMPS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DMPS:392:FUNC CA PP")
  field(DOL4, "MGNT:DMPS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DMPS:392:FUNC CA PP")
  field(DOL5, "MGNT:DMPS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DMPS:392:FUNC CA PP")
  field(DOL6, "MGNT:DMPS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DMPS:392:FUNC CA PP")
  field(DOL7, "MGNT:DMPS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DMPS:392:FUNC CA PP")
  field(DOL8, "MGNT:DMPS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DMPS:392:FUNC CA PP")
  field(DOL9, "MGNT:DMPS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DMPS:392:FUNC CA PP")
  field(DOLA, "MGNT:DMPS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DMPS:392:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DMPS:392:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DMPS:392:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DMPS:392:EDES.PROC PP")
    field(LNK2, "XCOR:DMPS:392:EACT.PROC PP")
    field(LNK3, "XCOR:DMPS:392:EERR.DISA PP")
    field(LNK4, "XCOR:DMPS:392:ECON.PROC PP")
    field(LNK5, "XCOR:DMPS:392:BMAGX.PROC PP")
    field(LNK6, "XCOR:DMPS:392:BMAGY.PROC PP")
    field(LNK7, "XCOR:DMPS:392:BLEM.PROC PP")
    field(LNK8, "XCOR:DMPS:392:BMOD.PROC PP")
    field(LNK9, "XCOR:DMPS:392:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DMPS:392:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DMPS:392:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DMPS:392:BMAX")
  field(DOL2, "XCOR:DMPS:392:BMAX")
  field(DOL3, "XCOR:DMPS:392:BMAX")
  field(DOL4, "XCOR:DMPS:392:BMIN")
  field(DOL5, "XCOR:DMPS:392:BMIN")
  field(DOL6, "XCOR:DMPS:392:BMIN")
  field(LNK1, "XCOR:DMPS:392:BMAGX.HOPR")
  field(LNK2, "XCOR:DMPS:392:BMAGY.HOPR")
  field(LNK3, "XCOR:DMPS:392:BLEM.HOPR")
  field(LNK4, "XCOR:DMPS:392:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DMPS:392:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DMPS:392:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DMPS:392:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DMPS:392:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DMPS:392:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DMPS:392:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DMPS:392:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPS:392:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPS:392:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DMPS:392:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPS:392:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DMPS:392:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DMPS:392:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DMPS:392:EDES NPP MS")
  field(INPB, "XCOR:DMPS:392:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DMPS:602:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPS:1:CTRL.RVAL")
  field(LNK1, "XCOR:DMPS:602:FUNC CA PP")
  field(DOL2, "MGNT:DMPS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DMPS:602:FUNC CA PP")
  field(DOL3, "MGNT:DMPS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DMPS:602:FUNC CA PP")
  field(DOL4, "MGNT:DMPS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DMPS:602:FUNC CA PP")
  field(DOL5, "MGNT:DMPS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DMPS:602:FUNC CA PP")
  field(DOL6, "MGNT:DMPS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DMPS:602:FUNC CA PP")
  field(DOL7, "MGNT:DMPS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DMPS:602:FUNC CA PP")
  field(DOL8, "MGNT:DMPS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DMPS:602:FUNC CA PP")
  field(DOL9, "MGNT:DMPS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DMPS:602:FUNC CA PP")
  field(DOLA, "MGNT:DMPS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DMPS:602:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DMPS:602:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DMPS:602:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DMPS:602:EDES.PROC PP")
    field(LNK2, "XCOR:DMPS:602:EACT.PROC PP")
    field(LNK3, "XCOR:DMPS:602:EERR.DISA PP")
    field(LNK4, "XCOR:DMPS:602:ECON.PROC PP")
    field(LNK5, "XCOR:DMPS:602:BMAGX.PROC PP")
    field(LNK6, "XCOR:DMPS:602:BMAGY.PROC PP")
    field(LNK7, "XCOR:DMPS:602:BLEM.PROC PP")
    field(LNK8, "XCOR:DMPS:602:BMOD.PROC PP")
    field(LNK9, "XCOR:DMPS:602:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DMPS:602:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DMPS:602:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DMPS:602:BMAX")
  field(DOL2, "XCOR:DMPS:602:BMAX")
  field(DOL3, "XCOR:DMPS:602:BMAX")
  field(DOL4, "XCOR:DMPS:602:BMIN")
  field(DOL5, "XCOR:DMPS:602:BMIN")
  field(DOL6, "XCOR:DMPS:602:BMIN")
  field(LNK1, "XCOR:DMPS:602:BMAGX.HOPR")
  field(LNK2, "XCOR:DMPS:602:BMAGY.HOPR")
  field(LNK3, "XCOR:DMPS:602:BLEM.HOPR")
  field(LNK4, "XCOR:DMPS:602:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DMPS:602:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DMPS:602:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DMPS:602:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DMPS:602:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DMPS:602:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DMPS:602:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DMPS:602:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPS:602:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPS:602:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DMPS:602:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DMPS:602:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DMPS:602:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DMPS:602:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DMPS:602:EDES NPP MS")
  field(INPB, "XCOR:DMPS:602:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DMPS:201:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPS:1:CTRL.RVAL")
  field(LNK1, "YCOR:DMPS:201:FUNC CA PP")
  field(DOL2, "MGNT:DMPS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DMPS:201:FUNC CA PP")
  field(DOL3, "MGNT:DMPS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DMPS:201:FUNC CA PP")
  field(DOL4, "MGNT:DMPS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DMPS:201:FUNC CA PP")
  field(DOL5, "MGNT:DMPS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DMPS:201:FUNC CA PP")
  field(DOL6, "MGNT:DMPS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DMPS:201:FUNC CA PP")
  field(DOL7, "MGNT:DMPS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DMPS:201:FUNC CA PP")
  field(DOL8, "MGNT:DMPS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DMPS:201:FUNC CA PP")
  field(DOL9, "MGNT:DMPS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DMPS:201:FUNC CA PP")
  field(DOLA, "MGNT:DMPS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DMPS:201:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DMPS:201:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DMPS:201:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DMPS:201:EDES.PROC PP")
    field(LNK2, "YCOR:DMPS:201:EACT.PROC PP")
    field(LNK3, "YCOR:DMPS:201:EERR.DISA PP")
    field(LNK4, "YCOR:DMPS:201:ECON.PROC PP")
    field(LNK5, "YCOR:DMPS:201:BMAGX.PROC PP")
    field(LNK6, "YCOR:DMPS:201:BMAGY.PROC PP")
    field(LNK7, "YCOR:DMPS:201:BLEM.PROC PP")
    field(LNK8, "YCOR:DMPS:201:BMOD.PROC PP")
    field(LNK9, "YCOR:DMPS:201:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DMPS:201:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DMPS:201:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DMPS:201:BMAX")
  field(DOL2, "YCOR:DMPS:201:BMAX")
  field(DOL3, "YCOR:DMPS:201:BMAX")
  field(DOL4, "YCOR:DMPS:201:BMIN")
  field(DOL5, "YCOR:DMPS:201:BMIN")
  field(DOL6, "YCOR:DMPS:201:BMIN")
  field(LNK1, "YCOR:DMPS:201:BMAGX.HOPR")
  field(LNK2, "YCOR:DMPS:201:BMAGY.HOPR")
  field(LNK3, "YCOR:DMPS:201:BLEM.HOPR")
  field(LNK4, "YCOR:DMPS:201:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DMPS:201:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DMPS:201:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DMPS:201:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DMPS:201:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DMPS:201:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DMPS:201:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DMPS:201:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPS:201:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPS:201:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DMPS:201:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPS:201:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DMPS:201:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DMPS:201:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DMPS:201:EDES NPP MS")
  field(INPB, "YCOR:DMPS:201:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DMPS:391:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPS:1:CTRL.RVAL")
  field(LNK1, "YCOR:DMPS:391:FUNC CA PP")
  field(DOL2, "MGNT:DMPS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DMPS:391:FUNC CA PP")
  field(DOL3, "MGNT:DMPS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DMPS:391:FUNC CA PP")
  field(DOL4, "MGNT:DMPS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DMPS:391:FUNC CA PP")
  field(DOL5, "MGNT:DMPS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DMPS:391:FUNC CA PP")
  field(DOL6, "MGNT:DMPS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DMPS:391:FUNC CA PP")
  field(DOL7, "MGNT:DMPS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DMPS:391:FUNC CA PP")
  field(DOL8, "MGNT:DMPS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DMPS:391:FUNC CA PP")
  field(DOL9, "MGNT:DMPS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DMPS:391:FUNC CA PP")
  field(DOLA, "MGNT:DMPS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DMPS:391:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DMPS:391:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DMPS:391:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DMPS:391:EDES.PROC PP")
    field(LNK2, "YCOR:DMPS:391:EACT.PROC PP")
    field(LNK3, "YCOR:DMPS:391:EERR.DISA PP")
    field(LNK4, "YCOR:DMPS:391:ECON.PROC PP")
    field(LNK5, "YCOR:DMPS:391:BMAGX.PROC PP")
    field(LNK6, "YCOR:DMPS:391:BMAGY.PROC PP")
    field(LNK7, "YCOR:DMPS:391:BLEM.PROC PP")
    field(LNK8, "YCOR:DMPS:391:BMOD.PROC PP")
    field(LNK9, "YCOR:DMPS:391:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DMPS:391:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DMPS:391:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DMPS:391:BMAX")
  field(DOL2, "YCOR:DMPS:391:BMAX")
  field(DOL3, "YCOR:DMPS:391:BMAX")
  field(DOL4, "YCOR:DMPS:391:BMIN")
  field(DOL5, "YCOR:DMPS:391:BMIN")
  field(DOL6, "YCOR:DMPS:391:BMIN")
  field(LNK1, "YCOR:DMPS:391:BMAGX.HOPR")
  field(LNK2, "YCOR:DMPS:391:BMAGY.HOPR")
  field(LNK3, "YCOR:DMPS:391:BLEM.HOPR")
  field(LNK4, "YCOR:DMPS:391:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DMPS:391:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DMPS:391:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DMPS:391:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DMPS:391:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DMPS:391:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DMPS:391:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DMPS:391:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPS:391:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPS:391:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DMPS:391:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPS:391:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DMPS:391:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DMPS:391:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DMPS:391:EDES NPP MS")
  field(INPB, "YCOR:DMPS:391:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DMPS:440:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPS:1:CTRL.RVAL")
  field(LNK1, "YCOR:DMPS:440:FUNC CA PP")
  field(DOL2, "MGNT:DMPS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DMPS:440:FUNC CA PP")
  field(DOL3, "MGNT:DMPS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DMPS:440:FUNC CA PP")
  field(DOL4, "MGNT:DMPS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DMPS:440:FUNC CA PP")
  field(DOL5, "MGNT:DMPS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DMPS:440:FUNC CA PP")
  field(DOL6, "MGNT:DMPS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DMPS:440:FUNC CA PP")
  field(DOL7, "MGNT:DMPS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DMPS:440:FUNC CA PP")
  field(DOL8, "MGNT:DMPS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DMPS:440:FUNC CA PP")
  field(DOL9, "MGNT:DMPS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DMPS:440:FUNC CA PP")
  field(DOLA, "MGNT:DMPS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DMPS:440:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DMPS:440:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DMPS:440:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DMPS:440:EDES.PROC PP")
    field(LNK2, "YCOR:DMPS:440:EACT.PROC PP")
    field(LNK3, "YCOR:DMPS:440:EERR.DISA PP")
    field(LNK4, "YCOR:DMPS:440:ECON.PROC PP")
    field(LNK5, "YCOR:DMPS:440:BMAGX.PROC PP")
    field(LNK6, "YCOR:DMPS:440:BMAGY.PROC PP")
    field(LNK7, "YCOR:DMPS:440:BLEM.PROC PP")
    field(LNK8, "YCOR:DMPS:440:BMOD.PROC PP")
    field(LNK9, "YCOR:DMPS:440:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DMPS:440:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DMPS:440:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DMPS:440:BMAX")
  field(DOL2, "YCOR:DMPS:440:BMAX")
  field(DOL3, "YCOR:DMPS:440:BMAX")
  field(DOL4, "YCOR:DMPS:440:BMIN")
  field(DOL5, "YCOR:DMPS:440:BMIN")
  field(DOL6, "YCOR:DMPS:440:BMIN")
  field(LNK1, "YCOR:DMPS:440:BMAGX.HOPR")
  field(LNK2, "YCOR:DMPS:440:BMAGY.HOPR")
  field(LNK3, "YCOR:DMPS:440:BLEM.HOPR")
  field(LNK4, "YCOR:DMPS:440:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DMPS:440:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DMPS:440:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DMPS:440:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DMPS:440:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DMPS:440:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DMPS:440:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DMPS:440:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPS:440:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPS:440:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DMPS:440:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DMPS:440:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DMPS:440:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DMPS:440:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DMPS:440:EDES NPP MS")
  field(INPB, "YCOR:DMPS:440:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:220:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:220:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:220:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:220:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:220:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:220:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:220:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:220:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:220:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:220:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:220:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:220:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:220:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:220:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:220:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:220:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:220:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:220:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:220:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:220:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:220:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:220:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:220:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:220:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:220:BMAX")
  field(DOL2, "BEND:LTUH:220:BMAX")
  field(DOL3, "BEND:LTUH:220:BMAX")
  field(DOL4, "BEND:LTUH:220:BMIN")
  field(DOL5, "BEND:LTUH:220:BMIN")
  field(DOL6, "BEND:LTUH:220:BMIN")
  field(LNK1, "BEND:LTUH:220:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:220:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:220:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:220:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:220:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:220:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:220:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:220:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:220:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:220:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:220:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:220:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DMPH:400:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:220:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DMPH:400:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:220:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:220:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DMPH:400:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:220:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:220:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:220:EDES NPP MS")
  field(INPB, "BEND:LTUH:220:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:280:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:280:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:280:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:280:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:280:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:280:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:280:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:280:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:280:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:280:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:280:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:280:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:280:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:280:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:280:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:280:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:280:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:280:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:280:BMAX")
  field(DOL2, "BEND:LTUH:280:BMAX")
  field(DOL3, "BEND:LTUH:280:BMAX")
  field(DOL4, "BEND:LTUH:280:BMIN")
  field(DOL5, "BEND:LTUH:280:BMIN")
  field(DOL6, "BEND:LTUH:280:BMIN")
  field(LNK1, "BEND:LTUH:280:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:280:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:280:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:280:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:280:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DMPH:400:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DMPH:400:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DMPH:400:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:280:EDES NPP MS")
  field(INPB, "BEND:LTUH:280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:420:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:420:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:420:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:420:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:420:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:420:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:420:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:420:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:420:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:420:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:420:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:420:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:420:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:420:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:420:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:420:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:420:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:420:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:420:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:420:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:420:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:420:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:420:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:420:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:420:BMAX")
  field(DOL2, "BEND:LTUH:420:BMAX")
  field(DOL3, "BEND:LTUH:420:BMAX")
  field(DOL4, "BEND:LTUH:420:BMIN")
  field(DOL5, "BEND:LTUH:420:BMIN")
  field(DOL6, "BEND:LTUH:420:BMIN")
  field(LNK1, "BEND:LTUH:420:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:420:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:420:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:420:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:420:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:420:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:420:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:420:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:420:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:420:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:420:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:420:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DMPH:400:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:420:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DMPH:400:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:420:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:420:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DMPH:400:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:420:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:420:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:420:EDES NPP MS")
  field(INPB, "BEND:LTUH:420:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUH:480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUH:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUH:480:FUNC CA PP")
  field(DOL2, "MGNT:LTUH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUH:480:FUNC CA PP")
  field(DOL3, "MGNT:LTUH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUH:480:FUNC CA PP")
  field(DOL4, "MGNT:LTUH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUH:480:FUNC CA PP")
  field(DOL5, "MGNT:LTUH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUH:480:FUNC CA PP")
  field(DOL6, "MGNT:LTUH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUH:480:FUNC CA PP")
  field(DOL7, "MGNT:LTUH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUH:480:FUNC CA PP")
  field(DOL8, "MGNT:LTUH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUH:480:FUNC CA PP")
  field(DOL9, "MGNT:LTUH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUH:480:FUNC CA PP")
  field(DOLA, "MGNT:LTUH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUH:480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUH:480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUH:480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUH:480:EDES.PROC PP")
    field(LNK2, "BEND:LTUH:480:EACT.PROC PP")
    field(LNK3, "BEND:LTUH:480:EERR.DISA PP")
    field(LNK4, "BEND:LTUH:480:ECON.PROC PP")
    field(LNK5, "BEND:LTUH:480:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUH:480:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUH:480:BLEM.PROC PP")
    field(LNK8, "BEND:LTUH:480:BMOD.PROC PP")
    field(LNK9, "BEND:LTUH:480:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUH:480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUH:480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUH:480:BMAX")
  field(DOL2, "BEND:LTUH:480:BMAX")
  field(DOL3, "BEND:LTUH:480:BMAX")
  field(DOL4, "BEND:LTUH:480:BMIN")
  field(DOL5, "BEND:LTUH:480:BMIN")
  field(DOL6, "BEND:LTUH:480:BMIN")
  field(LNK1, "BEND:LTUH:480:BMAGX.HOPR")
  field(LNK2, "BEND:LTUH:480:BMAGY.HOPR")
  field(LNK3, "BEND:LTUH:480:BLEM.HOPR")
  field(LNK4, "BEND:LTUH:480:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUH:480:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUH:480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUH:480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUH:480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUH:480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUH:480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DMPH:400:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DMPH:400:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUH:480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DMPH:400:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUH:480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUH:480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUH:480:EDES NPP MS")
  field(INPB, "BEND:LTUH:480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DMPH:410:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "BEND:DMPH:410:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DMPH:410:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DMPH:410:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DMPH:410:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DMPH:410:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DMPH:410:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DMPH:410:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DMPH:410:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DMPH:410:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DMPH:410:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DMPH:410:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DMPH:410:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DMPH:410:EDES.PROC PP")
    field(LNK2, "BEND:DMPH:410:EACT.PROC PP")
    field(LNK3, "BEND:DMPH:410:EERR.DISA PP")
    field(LNK4, "BEND:DMPH:410:ECON.PROC PP")
    field(LNK5, "BEND:DMPH:410:BMAGX.PROC PP")
    field(LNK6, "BEND:DMPH:410:BMAGY.PROC PP")
    field(LNK7, "BEND:DMPH:410:BLEM.PROC PP")
    field(LNK8, "BEND:DMPH:410:BMOD.PROC PP")
    field(LNK9, "BEND:DMPH:410:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DMPH:410:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DMPH:410:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DMPH:410:BMAX")
  field(DOL2, "BEND:DMPH:410:BMAX")
  field(DOL3, "BEND:DMPH:410:BMAX")
  field(DOL4, "BEND:DMPH:410:BMIN")
  field(DOL5, "BEND:DMPH:410:BMIN")
  field(DOL6, "BEND:DMPH:410:BMIN")
  field(LNK1, "BEND:DMPH:410:BMAGX.HOPR")
  field(LNK2, "BEND:DMPH:410:BMAGY.HOPR")
  field(LNK3, "BEND:DMPH:410:BLEM.HOPR")
  field(LNK4, "BEND:DMPH:410:BMAGX.LOPR PP")
  field(LNK5, "BEND:DMPH:410:BMAGY.LOPR PP")
  field(LNK6, "BEND:DMPH:410:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DMPH:410:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DMPH:410:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DMPH:410:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DMPH:410:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DMPH:410:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPH:410:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DMPH:400:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPH:410:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DMPH:400:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DMPH:410:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPH:410:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DMPH:400:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DMPH:410:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DMPH:410:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DMPH:410:EDES NPP MS")
  field(INPB, "BEND:DMPH:410:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DMPH:420:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "BEND:DMPH:420:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DMPH:420:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DMPH:420:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DMPH:420:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DMPH:420:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DMPH:420:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DMPH:420:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DMPH:420:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DMPH:420:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DMPH:420:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DMPH:420:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DMPH:420:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DMPH:420:EDES.PROC PP")
    field(LNK2, "BEND:DMPH:420:EACT.PROC PP")
    field(LNK3, "BEND:DMPH:420:EERR.DISA PP")
    field(LNK4, "BEND:DMPH:420:ECON.PROC PP")
    field(LNK5, "BEND:DMPH:420:BMAGX.PROC PP")
    field(LNK6, "BEND:DMPH:420:BMAGY.PROC PP")
    field(LNK7, "BEND:DMPH:420:BLEM.PROC PP")
    field(LNK8, "BEND:DMPH:420:BMOD.PROC PP")
    field(LNK9, "BEND:DMPH:420:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DMPH:420:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DMPH:420:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DMPH:420:BMAX")
  field(DOL2, "BEND:DMPH:420:BMAX")
  field(DOL3, "BEND:DMPH:420:BMAX")
  field(DOL4, "BEND:DMPH:420:BMIN")
  field(DOL5, "BEND:DMPH:420:BMIN")
  field(DOL6, "BEND:DMPH:420:BMIN")
  field(LNK1, "BEND:DMPH:420:BMAGX.HOPR")
  field(LNK2, "BEND:DMPH:420:BMAGY.HOPR")
  field(LNK3, "BEND:DMPH:420:BLEM.HOPR")
  field(LNK4, "BEND:DMPH:420:BMAGX.LOPR PP")
  field(LNK5, "BEND:DMPH:420:BMAGY.LOPR PP")
  field(LNK6, "BEND:DMPH:420:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DMPH:420:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DMPH:420:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DMPH:420:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DMPH:420:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DMPH:420:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPH:420:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DMPH:400:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPH:420:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DMPH:400:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DMPH:420:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPH:420:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DMPH:400:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DMPH:420:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DMPH:420:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DMPH:420:EDES NPP MS")
  field(INPB, "BEND:DMPH:420:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DMPH:600:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:DMPH:600:FUNC CA PP")
  field(DOL2, "MGNT:DMPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DMPH:600:FUNC CA PP")
  field(DOL3, "MGNT:DMPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DMPH:600:FUNC CA PP")
  field(DOL4, "MGNT:DMPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DMPH:600:FUNC CA PP")
  field(DOL5, "MGNT:DMPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DMPH:600:FUNC CA PP")
  field(DOL6, "MGNT:DMPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DMPH:600:FUNC CA PP")
  field(DOL7, "MGNT:DMPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DMPH:600:FUNC CA PP")
  field(DOL8, "MGNT:DMPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DMPH:600:FUNC CA PP")
  field(DOL9, "MGNT:DMPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DMPH:600:FUNC CA PP")
  field(DOLA, "MGNT:DMPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DMPH:600:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DMPH:600:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DMPH:600:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DMPH:600:EDES.PROC PP")
    field(LNK2, "QUAD:DMPH:600:EACT.PROC PP")
    field(LNK3, "QUAD:DMPH:600:EERR.DISA PP")
    field(LNK4, "QUAD:DMPH:600:ECON.PROC PP")
    field(LNK5, "QUAD:DMPH:600:BMAGX.PROC PP")
    field(LNK6, "QUAD:DMPH:600:BMAGY.PROC PP")
    field(LNK7, "QUAD:DMPH:600:BLEM.PROC PP")
    field(LNK8, "QUAD:DMPH:600:BMOD.PROC PP")
    field(LNK9, "QUAD:DMPH:600:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DMPH:600:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DMPH:600:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DMPH:600:BMAX")
  field(DOL2, "QUAD:DMPH:600:BMAX")
  field(DOL3, "QUAD:DMPH:600:BMAX")
  field(DOL4, "QUAD:DMPH:600:BMIN")
  field(DOL5, "QUAD:DMPH:600:BMIN")
  field(DOL6, "QUAD:DMPH:600:BMIN")
  field(LNK1, "QUAD:DMPH:600:BMAGX.HOPR")
  field(LNK2, "QUAD:DMPH:600:BMAGY.HOPR")
  field(LNK3, "QUAD:DMPH:600:BLEM.HOPR")
  field(LNK4, "QUAD:DMPH:600:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DMPH:600:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DMPH:600:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPH:600:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPH:600:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DMPH:600:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DMPH:600:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DMPH:600:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPH:600:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DMPH:500:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPH:600:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DMPH:500:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DMPH:600:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPH:600:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DMPH:500:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DMPH:600:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DMPH:600:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DMPH:600:EDES NPP MS")
  field(INPB, "QUAD:DMPH:600:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:175:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:175:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:175:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:175:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:175:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:175:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:175:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:175:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:175:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:175:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:175:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:175:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:175:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:175:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:175:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:175:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:175:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:175:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:175:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:175:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:175:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:175:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:175:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:175:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:175:BMAX")
  field(DOL2, "BEND:LTUS:175:BMAX")
  field(DOL3, "BEND:LTUS:175:BMAX")
  field(DOL4, "BEND:LTUS:175:BMIN")
  field(DOL5, "BEND:LTUS:175:BMIN")
  field(DOL6, "BEND:LTUS:175:BMIN")
  field(LNK1, "BEND:LTUS:175:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:175:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:175:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:175:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:175:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:175:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:175:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:175:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:175:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/C")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:175:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/C")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:175:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:175:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DMPS:400:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:175:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DMPS:400:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:175:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:175:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DMPS:400:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:175:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:175:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:175:EDES NPP MS")
  field(INPB, "BEND:LTUS:175:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:LTUS:460:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:LTUS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:LTUS:1:CTRL.RVAL")
  field(LNK1, "BEND:LTUS:460:FUNC CA PP")
  field(DOL2, "MGNT:LTUS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:LTUS:460:FUNC CA PP")
  field(DOL3, "MGNT:LTUS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:LTUS:460:FUNC CA PP")
  field(DOL4, "MGNT:LTUS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:LTUS:460:FUNC CA PP")
  field(DOL5, "MGNT:LTUS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:LTUS:460:FUNC CA PP")
  field(DOL6, "MGNT:LTUS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:LTUS:460:FUNC CA PP")
  field(DOL7, "MGNT:LTUS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:LTUS:460:FUNC CA PP")
  field(DOL8, "MGNT:LTUS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:LTUS:460:FUNC CA PP")
  field(DOL9, "MGNT:LTUS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:LTUS:460:FUNC CA PP")
  field(DOLA, "MGNT:LTUS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:LTUS:460:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:LTUS:460:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:LTUS:460:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:LTUS:460:EDES.PROC PP")
    field(LNK2, "BEND:LTUS:460:EACT.PROC PP")
    field(LNK3, "BEND:LTUS:460:EERR.DISA PP")
    field(LNK4, "BEND:LTUS:460:ECON.PROC PP")
    field(LNK5, "BEND:LTUS:460:BMAGX.PROC PP")
    field(LNK6, "BEND:LTUS:460:BMAGY.PROC PP")
    field(LNK7, "BEND:LTUS:460:BLEM.PROC PP")
    field(LNK8, "BEND:LTUS:460:BMOD.PROC PP")
    field(LNK9, "BEND:LTUS:460:EDESSAVE.PROC PP")
    field(LNKA, "BEND:LTUS:460:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:LTUS:460:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:LTUS:460:BMAX")
  field(DOL2, "BEND:LTUS:460:BMAX")
  field(DOL3, "BEND:LTUS:460:BMAX")
  field(DOL4, "BEND:LTUS:460:BMIN")
  field(DOL5, "BEND:LTUS:460:BMIN")
  field(DOL6, "BEND:LTUS:460:BMIN")
  field(LNK1, "BEND:LTUS:460:BMAGX.HOPR")
  field(LNK2, "BEND:LTUS:460:BMAGY.HOPR")
  field(LNK3, "BEND:LTUS:460:BLEM.HOPR")
  field(LNK4, "BEND:LTUS:460:BMAGX.LOPR PP")
  field(LNK5, "BEND:LTUS:460:BMAGY.LOPR PP")
  field(LNK6, "BEND:LTUS:460:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:460:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:LTUS:460:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:LTUS:460:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/C")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:LTUS:460:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/C")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:LTUS:460:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:460:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DMPS:400:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:460:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DMPS:400:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:460:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:LTUS:460:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DMPS:400:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:LTUS:460:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:LTUS:460:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:LTUS:460:EDES NPP MS")
  field(INPB, "BEND:LTUS:460:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DMPS:410:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPS:1:CTRL.RVAL")
  field(LNK1, "BEND:DMPS:410:FUNC CA PP")
  field(DOL2, "MGNT:DMPS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DMPS:410:FUNC CA PP")
  field(DOL3, "MGNT:DMPS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DMPS:410:FUNC CA PP")
  field(DOL4, "MGNT:DMPS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DMPS:410:FUNC CA PP")
  field(DOL5, "MGNT:DMPS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DMPS:410:FUNC CA PP")
  field(DOL6, "MGNT:DMPS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DMPS:410:FUNC CA PP")
  field(DOL7, "MGNT:DMPS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DMPS:410:FUNC CA PP")
  field(DOL8, "MGNT:DMPS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DMPS:410:FUNC CA PP")
  field(DOL9, "MGNT:DMPS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DMPS:410:FUNC CA PP")
  field(DOLA, "MGNT:DMPS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DMPS:410:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DMPS:410:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DMPS:410:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DMPS:410:EDES.PROC PP")
    field(LNK2, "BEND:DMPS:410:EACT.PROC PP")
    field(LNK3, "BEND:DMPS:410:EERR.DISA PP")
    field(LNK4, "BEND:DMPS:410:ECON.PROC PP")
    field(LNK5, "BEND:DMPS:410:BMAGX.PROC PP")
    field(LNK6, "BEND:DMPS:410:BMAGY.PROC PP")
    field(LNK7, "BEND:DMPS:410:BLEM.PROC PP")
    field(LNK8, "BEND:DMPS:410:BMOD.PROC PP")
    field(LNK9, "BEND:DMPS:410:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DMPS:410:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DMPS:410:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DMPS:410:BMAX")
  field(DOL2, "BEND:DMPS:410:BMAX")
  field(DOL3, "BEND:DMPS:410:BMAX")
  field(DOL4, "BEND:DMPS:410:BMIN")
  field(DOL5, "BEND:DMPS:410:BMIN")
  field(DOL6, "BEND:DMPS:410:BMIN")
  field(LNK1, "BEND:DMPS:410:BMAGX.HOPR")
  field(LNK2, "BEND:DMPS:410:BMAGY.HOPR")
  field(LNK3, "BEND:DMPS:410:BLEM.HOPR")
  field(LNK4, "BEND:DMPS:410:BMAGX.LOPR PP")
  field(LNK5, "BEND:DMPS:410:BMAGY.LOPR PP")
  field(LNK6, "BEND:DMPS:410:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DMPS:410:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DMPS:410:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DMPS:410:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/C")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DMPS:410:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/C")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DMPS:410:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPS:410:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DMPS:400:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPS:410:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DMPS:400:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DMPS:410:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPS:410:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DMPS:400:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DMPS:410:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DMPS:410:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DMPS:410:EDES NPP MS")
  field(INPB, "BEND:DMPS:410:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DMPS:420:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPS:1:CTRL.RVAL")
  field(LNK1, "BEND:DMPS:420:FUNC CA PP")
  field(DOL2, "MGNT:DMPS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DMPS:420:FUNC CA PP")
  field(DOL3, "MGNT:DMPS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DMPS:420:FUNC CA PP")
  field(DOL4, "MGNT:DMPS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DMPS:420:FUNC CA PP")
  field(DOL5, "MGNT:DMPS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DMPS:420:FUNC CA PP")
  field(DOL6, "MGNT:DMPS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DMPS:420:FUNC CA PP")
  field(DOL7, "MGNT:DMPS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DMPS:420:FUNC CA PP")
  field(DOL8, "MGNT:DMPS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DMPS:420:FUNC CA PP")
  field(DOL9, "MGNT:DMPS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DMPS:420:FUNC CA PP")
  field(DOLA, "MGNT:DMPS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DMPS:420:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DMPS:420:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DMPS:420:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DMPS:420:EDES.PROC PP")
    field(LNK2, "BEND:DMPS:420:EACT.PROC PP")
    field(LNK3, "BEND:DMPS:420:EERR.DISA PP")
    field(LNK4, "BEND:DMPS:420:ECON.PROC PP")
    field(LNK5, "BEND:DMPS:420:BMAGX.PROC PP")
    field(LNK6, "BEND:DMPS:420:BMAGY.PROC PP")
    field(LNK7, "BEND:DMPS:420:BLEM.PROC PP")
    field(LNK8, "BEND:DMPS:420:BMOD.PROC PP")
    field(LNK9, "BEND:DMPS:420:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DMPS:420:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DMPS:420:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DMPS:420:BMAX")
  field(DOL2, "BEND:DMPS:420:BMAX")
  field(DOL3, "BEND:DMPS:420:BMAX")
  field(DOL4, "BEND:DMPS:420:BMIN")
  field(DOL5, "BEND:DMPS:420:BMIN")
  field(DOL6, "BEND:DMPS:420:BMIN")
  field(LNK1, "BEND:DMPS:420:BMAGX.HOPR")
  field(LNK2, "BEND:DMPS:420:BMAGY.HOPR")
  field(LNK3, "BEND:DMPS:420:BLEM.HOPR")
  field(LNK4, "BEND:DMPS:420:BMAGX.LOPR PP")
  field(LNK5, "BEND:DMPS:420:BMAGY.LOPR PP")
  field(LNK6, "BEND:DMPS:420:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DMPS:420:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DMPS:420:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DMPS:420:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/C")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DMPS:420:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/C")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DMPS:420:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPS:420:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DMPS:400:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPS:420:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DMPS:400:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DMPS:420:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DMPS:420:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DMPS:400:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DMPS:420:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DMPS:420:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DMPS:420:EDES NPP MS")
  field(INPB, "BEND:DMPS:420:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DMPS:600:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DMPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DMPS:1:CTRL.RVAL")
  field(LNK1, "QUAD:DMPS:600:FUNC CA PP")
  field(DOL2, "MGNT:DMPS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DMPS:600:FUNC CA PP")
  field(DOL3, "MGNT:DMPS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DMPS:600:FUNC CA PP")
  field(DOL4, "MGNT:DMPS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DMPS:600:FUNC CA PP")
  field(DOL5, "MGNT:DMPS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DMPS:600:FUNC CA PP")
  field(DOL6, "MGNT:DMPS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DMPS:600:FUNC CA PP")
  field(DOL7, "MGNT:DMPS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DMPS:600:FUNC CA PP")
  field(DOL8, "MGNT:DMPS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DMPS:600:FUNC CA PP")
  field(DOL9, "MGNT:DMPS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DMPS:600:FUNC CA PP")
  field(DOLA, "MGNT:DMPS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DMPS:600:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DMPS:600:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DMPS:600:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DMPS:600:EDES.PROC PP")
    field(LNK2, "QUAD:DMPS:600:EACT.PROC PP")
    field(LNK3, "QUAD:DMPS:600:EERR.DISA PP")
    field(LNK4, "QUAD:DMPS:600:ECON.PROC PP")
    field(LNK5, "QUAD:DMPS:600:BMAGX.PROC PP")
    field(LNK6, "QUAD:DMPS:600:BMAGY.PROC PP")
    field(LNK7, "QUAD:DMPS:600:BLEM.PROC PP")
    field(LNK8, "QUAD:DMPS:600:BMOD.PROC PP")
    field(LNK9, "QUAD:DMPS:600:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DMPS:600:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DMPS:600:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DMPS:600:BMAX")
  field(DOL2, "QUAD:DMPS:600:BMAX")
  field(DOL3, "QUAD:DMPS:600:BMAX")
  field(DOL4, "QUAD:DMPS:600:BMIN")
  field(DOL5, "QUAD:DMPS:600:BMIN")
  field(DOL6, "QUAD:DMPS:600:BMIN")
  field(LNK1, "QUAD:DMPS:600:BMAGX.HOPR")
  field(LNK2, "QUAD:DMPS:600:BMAGY.HOPR")
  field(LNK3, "QUAD:DMPS:600:BLEM.HOPR")
  field(LNK4, "QUAD:DMPS:600:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DMPS:600:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DMPS:600:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPS:600:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DMPS:600:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DMPS:600:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DMPS:600:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DMPS:600:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPS:600:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DMPS:500:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPS:600:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DMPS:500:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DMPS:600:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DMPS:600:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DMPS:500:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DMPS:600:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DMPS:600:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DMPS:600:EDES NPP MS")
  field(INPB, "QUAD:DMPS:600:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}