#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "XCOR:EXT:368:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:201:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:EXT:368:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "XCOR:EXT:368:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:201:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "XCOR:EXT:368:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "2")
  field(LOLO, "-2")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "XCOR:EXT:368:BDELTAS")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "XCOR:EXT:368:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "XCOR:EXT:368:ICTRL PP")
}

# This record is processed by XCOR:EXT:368:ICON")
# Note: we are not setting alarms here.
record(ao, "XCOR:EXT:368:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "XCOR:EXT:368:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:EXT:368:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "XCOR:EXT:368:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(ao, "XCOR:EXT:368:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(FLNK, "XCOR:EXT:368:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "XCOR:EXT:368:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "XCOR:EXT:368:ISETPT.OMSL")

  field(DOL2, "XCOR:EXT:368:ICTRL")
  field(LNK2, "XCOR:EXT:368:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "XCOR:EXT:368:ISETPT.OMSL")
}

record(ao, "XCOR:EXT:368:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "2")
  field(FLNK, "XCOR:EXT:368:IMIN")
}

record(ao, "XCOR:EXT:368:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(VAL,  "-2")
  field(FLNK, "XCOR:EXT:368:IRANGE")
}

record(sel, "XCOR:EXT:368:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(NVL,  "XCOR:EXT:368:BACT.SEVR")
  field(INPA, "XCOR:EXT:368:IACT NPP MS")
  field(INPB, "XCOR:EXT:368:IACTPREVOK NPP MS")
  field(INPC, "XCOR:EXT:368:IACTPREVOK NPP MS")
  field(INPD, "XCOR:EXT:368:IACTPREVOK NPP MS")
}

record(sub, "XCOR:EXT:368:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:EXT:368:IDES")
  field(INPB, "XCOR:EXT:368:ISETPT.DRVH")
  field(INPC, "XCOR:EXT:368:ISETPT.DRVL")
  field(INPD, "XCOR:EXT:368:IDELTAS.I")
  field(INPE, "XCOR:EXT:368:IDELTAS.J")
  field(INPG, "XCOR:EXT:368:STATE")
  field(INPH, "XCOR:EXT:368:HSTA")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:EXT:368:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:EXT:368:IDES")
  field(INPB, "XCOR:EXT:368:ISETPT.DRVH")
  field(INPC, "XCOR:EXT:368:ISETPT.DRVL")
  field(INPD, "XCOR:EXT:368:IDELTAS.K")
  field(INPE, "XCOR:EXT:368:IDELTAS.L")
  field(INPG, "XCOR:EXT:368:STATE")
  field(INPH, "XCOR:EXT:368:HSTA")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:EXT:368:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "XCOR:EXT:368:BLIMITS")
  field(LNK1, "XCOR:EXT:368:IACTLIMITS.F PP")
  field(DOL2, "XCOR:EXT:368:IACTLIMITS.I")
  field(LNK2, "XCOR:EXT:368:IACT.HIGH")
  field(DOL3, "XCOR:EXT:368:IACTLIMITS.J")
  field(LNK3, "XCOR:EXT:368:IACT.LOW")
  field(DOL4, "XCOR:EXT:368:IACTLIMITS.K")
  field(LNK4, "XCOR:EXT:368:IACT.HIHI")
  field(DOL5, "XCOR:EXT:368:IACTLIMITS.L")
  field(LNK5, "XCOR:EXT:368:IACT.LOLO")
  field(DOL6, "XCOR:EXT:368:BLIMITS")
  field(LNK6, "XCOR:EXT:368:IMONLIMITS.F PP")
  field(DOL7, "XCOR:EXT:368:IMONLIMITS.I")
  field(LNK7, "XCOR:EXT:368:IMON.HIGH")
  field(DOL8, "XCOR:EXT:368:IMONLIMITS.J")
  field(LNK8, "XCOR:EXT:368:IMON.LOW")
  field(DOL9, "XCOR:EXT:368:IMONLIMITS.K")
  field(LNK9, "XCOR:EXT:368:IMON.HIHI")
  field(DOLA, "XCOR:EXT:368:IMONLIMITS.L")
  field(LNKA, "XCOR:EXT:368:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "XCOR:EXT:368:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "XCOR:EXT:368:TRIMBTOL")
  field(INPE, "XCOR:EXT:368:CHCKBTOL")
  field(INPF, "XCOR:EXT:368:BDELTAS.K")
  field(INPG, "XCOR:EXT:368:BDELTAS.L")
  field(INPH, "XCOR:EXT:368:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "XCOR:EXT:368:STDZITOLR")
  field(INPC, "XCOR:EXT:368:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:201:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "XCOR:EXT:368:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:201:RESET PP
#
record(bo, "XCOR:EXT:368:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:201:RESET PP")
}

record(bo, "XCOR:EXT:368:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:201:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "XCOR:EXT:368:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "XCOR:EXT:368:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:201:IRAMPRATE PP")
  field(FLNK, "XCOR:EXT:368:STDZDLY")
}


record(ao, "XCOR:EXT:368:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:201:ISETPT PP")
  field(DOL, "XCOR:EXT:368:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "XCOR:EXT:368:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:201:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:EXT:368:BMON")
}

record(ao, "XCOR:EXT:368:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:201:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "XCOR:EXT:368:IRIPLOK")
}

record(sub, "XCOR:EXT:368:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "XCOR:EXT:368:IRIPL.VAL")
  field(INPB, "XCOR:EXT:368:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:EXT:368:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:EXT:368:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "XCOR:EXT:368:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:201:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "XCOR:EXT:368:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:201:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "XCOR:EXT:368:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:EXT:368:IACTPREVOK")
  field(LNK2, "XCOR:EXT:368:IDIFF")
  field(LNK3, "XCOR:EXT:368:IADIFF")
  field(LNK4, "XCOR:EXT:368:IRATIO")
  field(LNK5, "XCOR:EXT:368:IDIRECT")
  field(LNK6, "XCOR:EXT:368:IACTPOL_CHECK")
}

record(calc, "XCOR:EXT:368:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:EXT:368:IDES")
  field(INPB, "XCOR:EXT:368:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(calc, "XCOR:EXT:368:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "XCOR:EXT:368:IDIFF")
  field(PREC, "9")
}

record(calc, "XCOR:EXT:368:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:EXT:368:IDIFF")
  field(INPB, "XCOR:EXT:368:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "XCOR:EXT:368:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "XCOR:EXT:368:IMIN")
  field(INPB,   "XCOR:EXT:368:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "XCOR:EXT:368:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "XCOR:EXT:368:IACT")
  field(INPB, "XCOR:EXT:368:IDES")
  field(INPC, "XCOR:EXT:368:ISETPT")
  field(INPD, "XCOR:EXT:368:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "XCOR:EXT:368:IADJUST PP")
}

record(bo, "XCOR:EXT:368:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "XCOR:EXT:368:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "XCOR:EXT:368:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "XCOR:EXT:368:IACT")
  field(FLNK, "XCOR:EXT:368:IACTPOL")
}
record(bo, "XCOR:EXT:368:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:EXT:368:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"XCOR:EXT:368:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:EXT:368:IDELTAS and the\n  XCOR:EXT:368:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"XCOR:EXT:368:IACT: \n  Get copy of XCOR:EXT:368:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"XCOR:EXT:368:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"XCOR:EXT:368:IDES:\n  Contains raw value calculated by \nXCOR:EXT:368:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nXCOR:EXT:368:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"XCOR:EXT:368:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  XCOR:EXT:368:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               XCOR:EXT:368:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"XCOR:EXT:368:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by XCOR:EXT:368:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, XCOR:EXT:368:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  XCOR:EXT:368:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "XCOR:EXT:368:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:EXT:368:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:EXT:368:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:EXT:368:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:EXT:368:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "XCOR:EXT:368:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "XCOR:EXT:368:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "XCOR:EXT:368:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "XCOR:EXT:368:TRIMTYPE.RVAL")
  field(INPB,   "XCOR:EXT:368:CONFIG.RVAL")
  field(OUT,    "XCOR:EXT:368:TRIMMAXNUM PP")
}
record(longout, "XCOR:EXT:368:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "XCOR:EXT:368:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "XCOR:EXT:368:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "XCOR:EXT:368:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "XCOR:EXT:368:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "XCOR:EXT:368:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "XCOR:EXT:368:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "XCOR:EXT:368:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "XCOR:EXT:368:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "XCOR:EXT:368:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "XCOR:EXT:368:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "XCOR:EXT:368:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "XCOR:EXT:368:IMOVE")
 field(INPB, "XCOR:EXT:368:IACT")
 field(INPC, "XCOR:EXT:368:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "XCOR:EXT:368:TRIMDLYPCT")
 field(INPF, "XCOR:EXT:368:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "XCOR:EXT:368:RAMPTIME_LEFT PP")
}

record(longout, "XCOR:EXT:368:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "XCOR:EXT:368:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "XCOR:EXT:368:RAMPDONE_CALC")
}

record(calc, "XCOR:EXT:368:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "XCOR:EXT:368:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "XCOR:EXT:368:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "XCOR:EXT:368:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:EXT:368:RAMPTIME_LEFT")
 field(OUT,  "XCOR:EXT:368:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "XCOR:EXT:368:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:EXT:368:RAMPTIME_LEFT NMS")
 field(OUT,  "XCOR:EXT:368:RAMPDONE PP")
}

record(bo, "XCOR:EXT:368:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "XCOR:EXT:368:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "XCOR:EXT:368:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "XCOR:EXT:368:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:EXT:368:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "XCOR:EXT:368:DEBUG.PROC PP")
  field(LNK2, "XCOR:EXT:368:STDZCYCLENUM.PROC PP")
  field(LNK3, "XCOR:EXT:368:STDZDISABLE.PROC PP")
  field(LNK4, "XCOR:EXT:368:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "XCOR:EXT:368:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "XCOR:EXT:368:STDZIMIN NPP NMS")
  field(INPB, "XCOR:EXT:368:STDZIMAX NPP NMS")
  field(INPC, "XCOR:EXT:368:STDZIFINAL NPP NMS")
  field(INPD, "XCOR:EXT:368:STDZCYCLENUM NPP NMS")
  field(INPE, "XCOR:EXT:368:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "XCOR:EXT:368:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "XCOR:EXT:368:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "XCOR:EXT:368:STDZWF PP")
  field(OUTB, "XCOR:EXT:368:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "XCOR:EXT:368:STDZWF")
}

record(mbbo, "XCOR:EXT:368:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "XCOR:EXT:368:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "XCOR:EXT:368:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "XCOR:EXT:368:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "XCOR:EXT:368:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "XCOR:EXT:368:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "XCOR:EXT:368:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:EXT:368:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:EXT:368:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "XCOR:EXT:368:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "XCOR:EXT:368:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "XCOR:EXT:368:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "XCOR:EXT:368:STDZIMIN")
}

record(ao, "XCOR:EXT:368:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "XCOR:EXT:368:STDZIMAX")
}

record(ao, "XCOR:EXT:368:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "2")
  field(FLNK, "XCOR:EXT:368:STDZIFINAL")
}

record(ao, "XCOR:EXT:368:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "XCOR:EXT:368:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "XCOR:EXT:368:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "XCOR:EXT:368:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "XCOR:EXT:368:STDZIMIN CP NMS")
  field(INPB, "XCOR:EXT:368:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "XCOR:EXT:368:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "XCOR:EXT:368:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "XCOR:EXT:368:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "XCOR:EXT:368:STDZIMIN CP NMS")
  field(INPB, "XCOR:EXT:368:STDZIMAX CP NMS")
  field(INPC, "XCOR:EXT:368:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "XCOR:EXT:368:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "XCOR:EXT:368:TRIMDLYPCT CP MS")
  field(INPB, "XCOR:EXT:368:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "XCOR:EXT:368:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "XCOR:EXT:368:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:EXT:368:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "XCOR:EXT:368:IDES.HOPR")
  field(INPB, "XCOR:EXT:368:STDZMINIPCT CPP NMS")
  field(INPC, "XCOR:EXT:368:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "XCOR:EXT:368:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "XCOR:EXT:368:IDES.HOPR")
  field(INPB, "XCOR:EXT:368:IDES.LOPR")
  field(INPC, "XCOR:EXT:368:STDZDIRECT.RVAL")
  field(INPD, "XCOR:EXT:368:STDZMINIDELTA")
  field(INPE, "XCOR:EXT:368:IDES")
  field(PREC, "5")
  field(FLNK, "XCOR:EXT:368:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "XCOR:EXT:368:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "XCOR:EXT:368:IDES.HOPR")
  field(INPB, "XCOR:EXT:368:IDES.LOPR")
  field(INPC, "XCOR:EXT:368:STDZDIRECT.RVAL")
  field(INPD, "XCOR:EXT:368:STDZMINIDELTA")
  field(INPE, "XCOR:EXT:368:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "XCOR:EXT:368:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "XCOR:EXT:368:IADJUST.RVAL")
  field(INPB, "XCOR:EXT:368:STDZDIRECT.RVAL")
  field(INPC, "XCOR:EXT:368:STDZOK.RVAL")
  field(INPD, "XCOR:EXT:368:STDZDISABLE.RVAL")
  field(INPE, "XCOR:EXT:368:STATE.RVAL CPP NMS")
  field(INPF, "XCOR:EXT:368:ICTRL.RVAL")
  field(INPG, "XCOR:EXT:368:STATE.SEVR")
  field(INPH, "XCOR:EXT:368:BDELTAS.M")
  field(INPI, "XCOR:EXT:368:IACT.SEVR")
  field(OUT,  "XCOR:EXT:368:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "XCOR:EXT:368:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "XCOR:EXT:368:STDZLOSTTOD.PROC")
  field(LNK2, "XCOR:EXT:368:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "XCOR:EXT:368:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "XCOR:EXT:368:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:EXT:368:IACT CP")
  field(INPB, "XCOR:EXT:368:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "XCOR:EXT:368:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "XCOR:EXT:368:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "XCOR:EXT:368:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:EXT:368:STDZIACTMAX")
  field(INPB, "XCOR:EXT:368:IACT")
  field(INPC, "XCOR:EXT:368:IDELTAS.I")
  field(OUT,  "XCOR:EXT:368:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "XCOR:EXT:368:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "XCOR:EXT:368:STDZOK.RVAL CP")
  field(INPB, "XCOR:EXT:368:STDZDISABLE.RVAL CP")
  field(INPC, "XCOR:EXT:368:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "XCOR:EXT:368:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "XCOR:EXT:368:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "XCOR:EXT:368:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "XCOR:EXT:368:CALBOK")
  field(INPB, "XCOR:EXT:368:CALBDISABLE")
  field(INPC, "XCOR:EXT:368:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "XCOR:EXT:368:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "XCOR:EXT:368:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "XCOR:EXT:368:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "XCOR:EXT:368:CALBSLOPE")
  field(DOL3, "XCOR:EXT:368:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "XCOR:EXT:368:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:EXT:368:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "XCOR:EXT:368:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "XCOR:EXT:368:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "XCOR:EXT:368:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "XCOR:EXT:368:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "XCOR:EXT:368:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "XCOR:EXT:368:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "XCOR:EXT:368:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "XCOR:EXT:368:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "XCOR:EXT:368:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "XCOR:EXT:368:IACT")
  field(INPD, "XCOR:EXT:368:DACSLOPE")
  field(INPE, "XCOR:EXT:368:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "XCOR:EXT:368:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "XCOR:EXT:368:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "2")
  field(HOPR, "2")
  field(DRVL, "-2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "XCOR:EXT:368:CALBIMAX")
}

record(ao, "XCOR:EXT:368:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "2")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(VAL,  "2")
  field(FLNK, "XCOR:EXT:368:CALBSTEPNUM")
}

record(ao, "XCOR:EXT:368:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL, "0")
}

record(longout, "XCOR:EXT:368:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:EXT:368:CALBIDELTA")
}

record(calc, "XCOR:EXT:368:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "XCOR:EXT:368:CALBIMAX")
  field(INPB, "XCOR:EXT:368:CALBIMIN")
  field(INPC, "XCOR:EXT:368:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "XCOR:EXT:368:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:201:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:201:IACT.HOPR")
  field(INPC, "XCOR:EXT:368:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "XCOR:EXT:368:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:EXT:368:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:EXT:368:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:EXT:368:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:EXT:368:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "XCOR:EXT:368:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:EXT:368:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:EXT:368:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:EXT:368:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "XCOR:EXT:368:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:EXT:368:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:EXT:368:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:EXT:368:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:EXT:368:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:EXT:368:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:EXT:368:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "XCOR:EXT:368:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:EXT:368:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "XCOR:EXT:368:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "XCOR:EXT:368:CALBSTEPNUM")
  field(INPB, "XCOR:EXT:368:CALBIACTWF")
  field(INPC, "XCOR:EXT:368:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "XCOR:EXT:368:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "XCOR:EXT:368:STDZITOL")

  field(INPH, "XCOR:EXT:368:DACSLOPE")
  field(INPI, "XCOR:EXT:368:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "XCOR:EXT:368:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "XCOR:EXT:368:CALBSTEPNUM")
  field(INPB, "XCOR:EXT:368:CALBIACTWF")
  field(INPC, "XCOR:EXT:368:DACWF")
  field(INPF, "XCOR:EXT:368:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe XCOR:EXT:368CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "XCOR:EXT:368:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "XCOR:EXT:368:DEGAUSIMIN.PROC PP")
  field(OUTB, "XCOR:EXT:368:DEGAUSIMAX.PROC PP")
  field(OUTC, "XCOR:EXT:368:DEGAUSTYPE.PROC PP")
  field(OUTD, "XCOR:EXT:368:DEGAUSSTEP.PROC PP")
  field(OUTE, "XCOR:EXT:368:MADNAME.PROC PP")
  field(OUTF, "XCOR:EXT:368:PSTYPE.PROC PP")
  field(OUTG, "XCOR:EXT:368:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "XCOR:EXT:368:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:EXT:368:DEGAUSIMIN NPP NMS")
  field(INPB, "XCOR:EXT:368:DEGAUSIMAX NPP NMS")
  field(INPC, "XCOR:EXT:368:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "XCOR:EXT:368:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "XCOR:EXT:368:PSTYPE NPP NMS")
  field(INPG, "XCOR:EXT:368:DEBUG.RVAL NPP NMS")
  field(INPH, "XCOR:EXT:368:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "XCOR:EXT:368:DEGAUSWF PP")
  field(OUTB, "XCOR:EXT:368:DEGAUSMSG PP")
  field(OUTC, "XCOR:EXT:368:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "XCOR:EXT:368:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"XCOR:EXT:368:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "XCOR:EXT:368:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "XCOR:EXT:368:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "XCOR:EXT:368:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "XCOR:EXT:368:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "XCOR:EXT:368:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "-2")
}
record(ao, "XCOR:EXT:368:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"XCOR:EXT:368:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "XCOR:EXT:368:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"XCOR:EXT:368:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "XCOR:EXT:368:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "XCOR:EXT:368:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "XCOR:EXT:368:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "XCOR:EXT:368:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:EXT:368:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:EXT:368:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:EXT:368:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:EXT:368:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "XCOR:EXT:368:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "XCOR:EXT:368:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "XCOR:EXT:368:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "XCOR:EXT:368:DEGAUS_IMAX")
  field(INPB, "XCOR:EXT:368:ISETPT")
  field(INPC, "XCOR:EXT:368:DEGAUSTYPE.RVAL")
  field(OUT,  "XCOR:EXT:368:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "XCOR:EXT:368:DEGAUS_IMAX_UPDATE")
}
record(seq, "XCOR:EXT:368:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "XCOR:EXT:368:ISETPT")
  field(LNK1, "XCOR:EXT:368:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "XCOR:EXT:368:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
  field(FLNK, "XCOR:EXT:368:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "XCOR:EXT:368:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "XCOR:EXT:368:DEGAUS_IMAX")
  field(FLNK, "XCOR:EXT:368:DEGAUS_IMAXPOL")
}
record(bo, "XCOR:EXT:368:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:EXT:368:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "XCOR:EXT:368:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "XCOR:EXT:368:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "XCOR:EXT:368:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "XCOR:EXT:368:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "XCOR:EXT:368:IACT")
  field(INPB, "XCOR:EXT:368:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "XCOR:EXT:368:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "XCOR:EXT:368:IACTPOL")
}
record(bo, "XCOR:EXT:368:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"XCOR:EXT:368:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "XCOR:EXT:368:DEGAUSENABLE CP")
  field(INPB, "XCOR:EXT:368:DEGAUSOK")
  field(INPC, "XCOR:EXT:368:STATE CP")
  field(INPD, "XCOR:EXT:368:STATE.SEVR")
  field(OUT,  "XCOR:EXT:368:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "XCOR:EXT:368:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "XCOR:EXT:368:DEGAUS_STATE_CHECK")
  field(LNK1, "XCOR:EXT:368:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "XCOR:EXT:368:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "XCOR:EXT:368:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "XCOR:EXT:368:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "XCOR:EXT:368:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "XCOR:EXT:368:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:EXT:368:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "XCOR:EXT:368:STATMSG.FRSV")
  field(LNK4, "XCOR:EXT:368:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:EXT:368:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "XCOR:EXT:368:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:EXT:368:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "XCOR:EXT:368:STATMSG.FRSV")
  field(LNK4, "XCOR:EXT:368:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:EXT:368:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "XCOR:EXT:368:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "XCOR:EXT:368:STATMSG.FRSV")
  field(LNK3, "XCOR:EXT:368:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "XCOR:EXT:368:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "XCOR:EXT:368:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "XCOR:EXT:368:STATMSG.FRSV PP")
  field(LNK3, "XCOR:EXT:368:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "XCOR:EXT:368:FUNC") {
  field(DESC, "XCOR:EXT:368 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "XCOR:EXT:368:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:EXT:368:CTRL") {
  field(DESC, "XCOR:EXT:368 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "XCOR:EXT:368:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "XCOR:EXT:368:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "XCOR:EXT:368:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "XCOR:EXT:368:BUSY") {
  field(DESC, "XCOR:EXT:368 Ctrl Done")
  field(DOL, "XCOR:EXT:368:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "XCOR:EXT:368:SELECT")
}

record(bo, "XCOR:EXT:368:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "XCOR:EXT:368:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:EXT:368:CTRLSTATE") {
  field(DESC, "XCOR:EXT:368 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("XCOR:EXT:368:CTRL",20,20,0,0,"XCOR:EXT:368:CTRL")
#! Field("XCOR:EXT:368:CTRL.OUT",16777215,1,"XCOR:EXT:368:CTRL.OUT")
#! Link("XCOR:EXT:368:CTRL.OUT","XCOR:EXT:368:SELECTEN.A")
#! Field("XCOR:EXT:368:CTRL.VAL",16777215,1,"XCOR:EXT:368:CTRL.VAL")
#! Record("XCOR:EXT:368:SELECTEN",321,381,0,0,"XCOR:EXT:368:SELECTEN")
#! Field("XCOR:EXT:368:SELECTEN.A",16777215,0,"XCOR:EXT:368:SELECTEN.A")
#! Field("XCOR:EXT:368:SELECTEN.FLNK",16777215,1,"XCOR:EXT:368:SELECTEN.FLNK")
#! Link("XCOR:EXT:368:SELECTEN.FLNK","XCOR:EXT:368:BUSY")
#! Field("XCOR:EXT:368:SELECTEN.VAL",16777215,1,"XCOR:EXT:368:SELECTEN.VAL")
#! Record("XCOR:EXT:368:BUSY",623,274,0,0,"XCOR:EXT:368:BUSY")
#! Field("XCOR:EXT:368:BUSY.DOL",16777215,0,"XCOR:EXT:368:BUSY.DOL")
#! Link("XCOR:EXT:368:BUSY.DOL","XCOR:EXT:368:SELECTEN.VAL")
#! Field("XCOR:EXT:368:BUSY.FLNK",16777215,1,"XCOR:EXT:368:BUSY.FLNK")
#! Link("XCOR:EXT:368:BUSY.FLNK","XCOR:EXT:368:SELECT")
#! Record("XCOR:EXT:368:SELECT",669,508,0,1,"XCOR:EXT:368:SELECT")
#! Record("XCOR:EXT:368:FUNC",940,120,0,0,"XCOR:EXT:368:FUNC")
#! Field("XCOR:EXT:368:FUNC.OUT",16777215,0,"XCOR:EXT:368:FUNC.OUT")
#! Link("XCOR:EXT:368:FUNC.OUT","XCOR:EXT:368:CTRL.VAL")
#! Record("XCOR:EXT:368:ABORT",193,41,0,0,"XCOR:EXT:368:ABORT")
#! Record("XCOR:EXT:368:CTRLSTATE",369,34,0,0,"XCOR:EXT:368:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"XCOR:EXT:368:SELECT is used for Multi-device selection.\nIt is enabled when associated XCOR:EXT:368:CTRL is \"0\" (DONE).\nIt is disabled when associated XCOR:EXT:368:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"XCOR:EXT:368:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "XCOR:EXT:368:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "XCOR:EXT:368:BCTRL.SEVR")
  field(OUT,  "XCOR:EXT:368:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "XCOR:EXT:368:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:EXT:368:BACT")
  field(INPB, "XCOR:EXT:368:POLYCOEF")
  field(INPC, "XCOR:EXT:368:POLYCOEF.A")
  field(INPD, "XCOR:EXT:368:POLYCOEF.B")
  field(INPE, "XCOR:EXT:368:IACT MS")
  field(INPF, "XCOR:EXT:368:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
  field(FLNK, "XCOR:EXT:368:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "XCOR:EXT:368:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:EXT:368:BDES")
  field(INPB, "XCOR:EXT:368:TRIMBTOL")
  field(INPC, "XCOR:EXT:368:TRIMBTOLR")
  field(INPD, "XCOR:EXT:368:CHCKBTOL")
  field(INPE, "XCOR:EXT:368:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "XCOR:EXT:368:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "XCOR:EXT:368:MPSBTOL")
  field(INPQ, "XCOR:EXT:368:MPSBTOLR")
  field(FLNK, "XCOR:EXT:368:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "XCOR:EXT:368:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "XCOR:EXT:368:BDES")
  field(INPB, "XCOR:EXT:368:BDELTAS.I")
  field(INPG, "XCOR:EXT:368:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "XCOR:EXT:368:BCON.HIGH")
  field(OUTB, "XCOR:EXT:368:BCON.LOW")
  field(OUTC, "XCOR:EXT:368:BCON.HIHI")
  field(OUTD, "XCOR:EXT:368:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:EXT:368:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "XCOR:EXT:368:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:EXT:368:BDIFF")
  field(LNK2, "XCOR:EXT:368:BADIFF")
  field(LNK3, "XCOR:EXT:368:BRATIO")
  field(LNK4, "XCOR:EXT:368:MPSLIMITS")
  field(LNK5, "XCOR:EXT:368:I2BSTATUS")
  field(LNK6, "XCOR:EXT:368:IACTFO.PROC")
}

record(calc, "XCOR:EXT:368:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:EXT:368:BDES")
  field(INPB, "XCOR:EXT:368:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "XCOR:EXT:368:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "XCOR:EXT:368:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "XCOR:EXT:368:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:EXT:368:BDIFF")
  field(INPB, "XCOR:EXT:368:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "XCOR:EXT:368:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "XCOR:EXT:368:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "XCOR:EXT:368:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:EXT:368:BMON")
  field(INPB, "XCOR:EXT:368:POLYCOEF")
  field(INPC, "XCOR:EXT:368:POLYCOEF.A")
  field(INPD, "XCOR:EXT:368:POLYCOEF.B")
  field(INPE, "XCOR:EXT:368:IMON MS")
  field(INPF, "XCOR:EXT:368:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:201:BDES CP
record(ao,  "XCOR:EXT:368:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.02098636")
   field(DRVL, "-0.02098636")
   field(HOPR, "0.02098636")
   field(LOPR, "-0.02098636")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "XCOR:EXT:368:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "XCOR:EXT:368:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:EXT:368:POLYCOEF")
  field(INPC, "XCOR:EXT:368:POLYCOEF.A")
  field(INPD, "XCOR:EXT:368:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "XCOR:EXT:368:BDES.DRVH")
  field(INPF, "XCOR:EXT:368:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:EXT:368:IDES")
}
record(sub, "XCOR:EXT:368:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:EXT:368:POLYCOEF")
  field(INPC, "XCOR:EXT:368:POLYCOEF.A")
  field(INPD, "XCOR:EXT:368:POLYCOEF.B")
  field(INPE, "XCOR:EXT:368:BDES.DRVH")
  field(INPF, "XCOR:EXT:368:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "XCOR:EXT:368:INOM")
}

record(sub, "XCOR:EXT:368:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:EXT:368:BDES.VAL")
  field(INPB, "XCOR:EXT:368:BDES.DRVH")
  field(INPC, "XCOR:EXT:368:BDES.DRVL")
  field(INPD, "XCOR:EXT:368:BDELTAS.I")
  field(INPE, "XCOR:EXT:368:BDELTAS.J")
  field(INPG, "XCOR:EXT:368:STATE")
  field(INPH, "XCOR:EXT:368:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:EXT:368:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:EXT:368:BDES.VAL")
  field(INPB, "XCOR:EXT:368:BDES.DRVH")
  field(INPC, "XCOR:EXT:368:BDES.DRVL")
  field(INPD, "XCOR:EXT:368:BDELTAS.K")
  field(INPE, "XCOR:EXT:368:BDELTAS.L")
  field(INPG, "XCOR:EXT:368:STATE")
  field(INPH, "XCOR:EXT:368:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:EXT:368:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "XCOR:EXT:368:BLIMITS")
  field(LNK1, "XCOR:EXT:368:BACTLIMITS.F PP")
  field(DOL2, "XCOR:EXT:368:BACTLIMITS.I")
  field(LNK2, "XCOR:EXT:368:BACT.HIGH")
  field(DOL3, "XCOR:EXT:368:BACTLIMITS.J")
  field(LNK3, "XCOR:EXT:368:BACT.LOW")
  field(DOL4, "XCOR:EXT:368:BACTLIMITS.K")
  field(LNK4, "XCOR:EXT:368:BACT.HIHI")
  field(DOL5, "XCOR:EXT:368:BACTLIMITS.L")
  field(LNK5, "XCOR:EXT:368:BACT.LOLO")
  field(DOL6, "XCOR:EXT:368:BLIMITS")
  field(LNK6, "XCOR:EXT:368:BMONLIMITS.F PP")
  field(DOL7, "XCOR:EXT:368:BMONLIMITS.I")
  field(LNK7, "XCOR:EXT:368:BMON.HIGH")
  field(DOL8, "XCOR:EXT:368:BMONLIMITS.J")
  field(LNK8, "XCOR:EXT:368:BMON.LOW")
  field(DOL9, "XCOR:EXT:368:BMONLIMITS.K")
  field(LNK9, "XCOR:EXT:368:BMON.HIHI")
  field(DOLA, "XCOR:EXT:368:BMONLIMITS.L")
  field(LNKA, "XCOR:EXT:368:BMON.LOLO")
  field(FLNK, "XCOR:EXT:368:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "XCOR:EXT:368:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "XCOR:EXT:368:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "XCOR:EXT:368:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "XCOR:EXT:368:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "XCOR:EXT:368:BCTRL.VAL")
  field(LNK2, "XCOR:EXT:368:BDES PP")

  field(DOL3, "1")
  field(LNK3, "XCOR:EXT:368:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "XCOR:EXT:368:CHECKSTDZLOST.PROC PP")

  field(DOL5, "XCOR:EXT:368:BCTRL.VAL")
  field(LNK5, "XCOR:EXT:368:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "XCOR:EXT:368:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "XCOR:EXT:368:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:EXT:368:POLYCOEF")
  field(INPC, "XCOR:EXT:368:POLYCOEF.A")
  field(INPD, "XCOR:EXT:368:POLYCOEF.B")
  field(INPE, "XCOR:EXT:368:BDES.DRVH")
  field(INPF, "XCOR:EXT:368:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:EXT:368:ISETPT")
}

record(ao, "XCOR:EXT:368:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "XCOR:EXT:368:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "XCX01")
}

record(ai, "XCOR:EXT:368:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "649.6727")
}

record(ao, "XCOR:EXT:368:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(FLNK, "XCOR:EXT:368:BSTEP")
}

record(ao, "XCOR:EXT:368:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(FLNK, "XCOR:EXT:368:BSTEP")
}

record(ao, "XCOR:EXT:368:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by XCOR:EXT:368:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "XCOR:EXT:368:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "XCOR:EXT:368:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "XCOR:EXT:368:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:EXT:368:POLYCOEF")
  field(INPC, "XCOR:EXT:368:POLYCOEF.A")
  field(INPD, "XCOR:EXT:368:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "XCOR:EXT:368:BCON.DRVH")
  field(INPF, "XCOR:EXT:368:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:EXT:368:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "XCOR:EXT:368:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "XCOR:EXT:368:BMAX")
  field(INPB, "XCOR:EXT:368:BMIN")
  field(INPC, "XCOR:EXT:368:BMIN.SEVR")
  field(INPD, "XCOR:EXT:368:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"XCOR:EXT:368:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "XCOR:EXT:368:ONLINE CP")
  field(OUT,  "XCOR:EXT:368:BCTRLDISABLEFOUT PP")
}

record(fanout, "XCOR:EXT:368:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "XCOR:EXT:368:BCTRLDISABLECALC")
  field(LNK1, "XCOR:EXT:368:BCTRLDISABLE")
  field(LNK2, "XCOR:EXT:368:BCTRLENABLE")
}

record(stringout, "XCOR:EXT:368:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:EXT:368:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "XCOR:EXT:368:BCTRLDISV_UPDATE")
}

record(stringout, "XCOR:EXT:368:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:EXT:368:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "XCOR:EXT:368:BCTRLDISV_UPDATE")
}

record(calcout, "XCOR:EXT:368:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "XCOR:EXT:368:ONLINE")
  field(OUT,  "XCOR:EXT:368:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"XCOR:EXT:368:BACT and MON\n  are processed via links from \n  XCOR:EXT:368:IACT (device raw value readback 1)\n  and\n  XCOR:EXT:368:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from XCOR:EXT:368:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = XCOR:EXT:368:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"XCOR:EXT:368:BDES\n  is processed when set by CA users or \n  XCOR:EXT:368:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"XCOR:EXT:368:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  XCOR:EXT:368:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (XCOR:EXT:368:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"XCOR:EXT:368:B*LIMITS and XCOR:EXT:368:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:EXT:368:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"XCOR:EXT:368:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"XCOR:EXT:368:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "XCOR:EXT:368:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:EXT:368:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "XCOR:EXT:368:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "XCOR:EXT:368:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:EXT:368:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:EXT:368:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:EXT:368:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "XCOR:EXT:368:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "XCOR:EXT:368:MPSLIMITS.E PP")
}

record(aSub, "XCOR:EXT:368:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "XCOR:EXT:368:MPS.RVAL")
  field(INPB, "XCOR:EXT:368:BADIFF")
  field(INPC, "XCOR:EXT:368:BDELTAS.N")
  field(INPD, "XCOR:EXT:368:BACT")
  field(INPE, "XCOR:EXT:368:MPSBITMASK.RVAL")
  field(INPF, "XCOR:EXT:368:MPSBLLIM")
  field(INPG, "XCOR:EXT:368:MPSBMIN")
  field(INPH, "XCOR:EXT:368:MPSBMAX")
  field(INPI, "XCOR:EXT:368:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "XCOR:EXT:368:INTOL.RVAL PP")
  field(OUTB, "XCOR:EXT:368:INTOL_BMIN.RVAL PP")
  field(OUTC, "XCOR:EXT:368:INTOL_BRANGE.RVAL PP")
  field(OUTD, "XCOR:EXT:368:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "XCOR:EXT:368:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:EXT:368:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:EXT:368:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:EXT:368:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:EXT:368:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:EXT:368:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:EXT:368:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:EXT:368:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "XCOR:EXT:368:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "XCOR:EXT:368:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:EXT:368:CHCKBTOL")
  field(INPB, "XCOR:EXT:368:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "XCOR:EXT:368:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "XCOR:EXT:368:CHCKBTOL")
  field(FLNK, "XCOR:EXT:368:CHCKITOL")
}

record(calc, "XCOR:EXT:368:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "XCOR:EXT:368:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "XCOR:EXT:368:BDES.HOPR")
  field(INPB, "XCOR:EXT:368:STABILITY")
  field(INPC, "XCOR:EXT:368:BDES.LOPR")
}

record(longout, "XCOR:EXT:368:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "XCOR:EXT:368:CHCKBTOL")
}

record(calc, "XCOR:EXT:368:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:EXT:368:POLYCOEF.B")
  field(INPB, "XCOR:EXT:368:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "XCOR:EXT:368:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "XCOR:EXT:368:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "XCOR:EXT:368:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "XCOR:EXT:368:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "XCOR:EXT:368:PAUGO")  
}

record(fanout, "XCOR:EXT:368:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "XCOR:EXT:368:PAUSTOP")
  field(LNK2, "XCOR:EXT:368:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "XCOR:EXT:368:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "XCOR:EXT:368:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:201:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:201:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "XCOR:EXT:368:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "XCOR:EXT:368:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:201:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:201:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "XCOR:EXT:368:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:201:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:EXT:368:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "XCOR:EXT:368:PSTYPE.RVAL")
  field(INPC, "XCOR:EXT:368:TURNEDOFF.RVAL")
  field(INPD, "XCOR:EXT:368:CONFIG.RVAL")
  field(INPE, "XCOR:EXT:368:PSCATEGORY.RVAL")
  field(INPF, "XCOR:EXT:368:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "XCOR:EXT:368:AUTOCTRL.RVAL")
  field(INPJ, "XCOR:EXT:368:OUTOFSERVICE.RVAL")
  field(INPL, "XCOR:EXT:368:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "XCOR:EXT:368:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "XCOR:EXT:368:PAU")
  field(INPP, "XCOR:EXT:368:CALBDISABLE.RVAL")
  field(INPQ, "XCOR:EXT:368:PTRBDISABLE.RVAL")
  field(INPR, "XCOR:EXT:368:TRIMDISABLE.RVAL")
  field(INPS, "XCOR:EXT:368:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "XCOR:EXT:368:FBCK")
  field(INPU, "XCOR:EXT:368:TRIMTYPE.RVAL")
  field(INPV, "XCOR:EXT:368:STDZDIRECT.RVAL")
  field(INPW, "XCOR:EXT:368:DEGAUSENABLE.RVAL")
  field(FLNK, "XCOR:EXT:368:HSTA")
}

record(longin, "XCOR:EXT:368:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "XCOR:EXT:368:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "XCOR:EXT:368:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "XCOR:EXT:368:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "XCOR:EXT:368:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:EXT:368:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:EXT:368:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:EXT:368:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by XCOR:EXT:368:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses XCOR:EXT:368:FBCK.
# This PV should be replaced by XCOR:EXT:368:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "XCOR:EXT:368:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "XCOR:EXT:368:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:EXT:368:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:EXT:368:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"XCOR:EXT:368:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "XCOR:EXT:368:OUTOFSERVICE NPP NMS")
  field(OUT,  "XCOR:EXT:368:ONLINE PP")
}
record(bo, "XCOR:EXT:368:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "XCOR:EXT:368:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:EXT:368:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "XCOR:EXT:368:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "XCOR:EXT:368:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "XCOR:EXT:368:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "XCOR:EXT:368:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "XCOR:EXT:368:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "XCOR:EXT:368:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:EXT:368:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:EXT:368:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:EXT:368:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "XCOR:EXT:368:TRIMTYPE")
}

record(stringout, "XCOR:EXT:368:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "XCOR:EXT:368:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "XCOR:EXT:368:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "XCOR:EXT:368:STATE.RVAL")
  field(INPB, "XCOR:EXT:368:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:EXT:368:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:EXT:368:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "XCOR:EXT:368:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "XCOR:EXT:368:STATE.RVAL")
  field(INPB, "XCOR:EXT:368:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:EXT:368:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:EXT:368:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "XCOR:EXT:368:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "XCOR:EXT:368:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "XCOR:EXT:368:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "XCOR:EXT:368:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "XCOR:EXT:368:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"XCOR:EXT:368:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("XCOR:EXT:368:TURNEDOFF",3140,1907,0,1,"XCOR:EXT:368:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:EXT:368:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "XCOR:EXT:368:BACT.STAT")
  field(INPB, "XCOR:EXT:368:BDES.STAT")
  field(INPC, "XCOR:EXT:368:IRIPL.STAT")
  field(INPD, "MCOR:EXT:201:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:201:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "XCOR:EXT:368:BACT.SEVR")
  field(INPH, "XCOR:EXT:368:BDES.SEVR")
  field(INPI, "XCOR:EXT:368:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:201:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:201:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "XCOR:EXT:368:STATE.RVAL")
  field(INPN, "XCOR:EXT:368:STDZOK")
  field(INPO, "XCOR:EXT:368:CALBOK")
  field(INPP, "XCOR:EXT:368:OUTOFSERVICE.RVAL")
  field(INPQ, "XCOR:EXT:368:CONFIG.RVAL")
  field(INPR, "XCOR:EXT:368:HSTA")
  field(INPS, "XCOR:EXT:368:CTRL.RVAL")
  field(INPT, "XCOR:EXT:368:DEGAUSOK") 
  field(INPV, "XCOR:EXT:368:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "XCOR:EXT:368:STAT")
}

record(longout, "XCOR:EXT:368:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "XCOR:EXT:368:STATCTRLSUB")
  field(DOL, "XCOR:EXT:368:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "XCOR:EXT:368:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "XCOR:EXT:368:STAT")
  field(INPB, "XCOR:EXT:368:HSTA")
  field(INPD, "XCOR:EXT:368:ONOFFCTRL.RVAL")
  field(FLNK, "XCOR:EXT:368:STATMSG")
}

record(mbbo, "XCOR:EXT:368:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:EXT:368:UNAVAILGO")
  field(DOL, "XCOR:EXT:368:STATCTRLSUB.W")
}

record(seq, "XCOR:EXT:368:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "XCOR:EXT:368:STATSUB.U")
  field(LNK1, "XCOR:EXT:368:UNAVAIL PP")
}

record(stringout, "XCOR:EXT:368:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"XCOR:EXT:368:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - XCOR:EXT:368:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - XCOR:EXT:368:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"XCOR:EXT:368STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - XCOR:EXT:368:STATUS\nC - XCOR:EXT:368:ON\nD - XCOR:EXT:368:STDZOK\nE - XCOR:EXT:368:CALBOK\nF - XCOR:EXT:368:BACTDRIFT (future)\nG -\nH- XCOR:EXT:368:DACSTATUS\nI -XCOR:EXT:368:ADCSTATUS\nJ - XCOR:EXT:368:BACTSTATUS\nK - XCOR:EXT:368:BDESSTATUS\nL - XCOR:EXT:368:RIPLSTATUS\n\nOutput:\nP - XCOR:EXT:368:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "XCOR:EXT:368:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "XCOR:EXT:368:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "XCOR:EXT:368:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "XCOR:EXT:368:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "YCOR:EXT:762:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:202:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:EXT:762:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "YCOR:EXT:762:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:202:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "YCOR:EXT:762:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "2")
  field(LOLO, "-2")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "YCOR:EXT:762:BDELTAS")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "YCOR:EXT:762:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "YCOR:EXT:762:ICTRL PP")
}

# This record is processed by YCOR:EXT:762:ICON")
# Note: we are not setting alarms here.
record(ao, "YCOR:EXT:762:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "YCOR:EXT:762:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:EXT:762:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "YCOR:EXT:762:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(ao, "YCOR:EXT:762:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(FLNK, "YCOR:EXT:762:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "YCOR:EXT:762:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "YCOR:EXT:762:ISETPT.OMSL")

  field(DOL2, "YCOR:EXT:762:ICTRL")
  field(LNK2, "YCOR:EXT:762:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "YCOR:EXT:762:ISETPT.OMSL")
}

record(ao, "YCOR:EXT:762:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "2")
  field(FLNK, "YCOR:EXT:762:IMIN")
}

record(ao, "YCOR:EXT:762:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(VAL,  "-2")
  field(FLNK, "YCOR:EXT:762:IRANGE")
}

record(sel, "YCOR:EXT:762:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(NVL,  "YCOR:EXT:762:BACT.SEVR")
  field(INPA, "YCOR:EXT:762:IACT NPP MS")
  field(INPB, "YCOR:EXT:762:IACTPREVOK NPP MS")
  field(INPC, "YCOR:EXT:762:IACTPREVOK NPP MS")
  field(INPD, "YCOR:EXT:762:IACTPREVOK NPP MS")
}

record(sub, "YCOR:EXT:762:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:EXT:762:IDES")
  field(INPB, "YCOR:EXT:762:ISETPT.DRVH")
  field(INPC, "YCOR:EXT:762:ISETPT.DRVL")
  field(INPD, "YCOR:EXT:762:IDELTAS.I")
  field(INPE, "YCOR:EXT:762:IDELTAS.J")
  field(INPG, "YCOR:EXT:762:STATE")
  field(INPH, "YCOR:EXT:762:HSTA")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:EXT:762:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:EXT:762:IDES")
  field(INPB, "YCOR:EXT:762:ISETPT.DRVH")
  field(INPC, "YCOR:EXT:762:ISETPT.DRVL")
  field(INPD, "YCOR:EXT:762:IDELTAS.K")
  field(INPE, "YCOR:EXT:762:IDELTAS.L")
  field(INPG, "YCOR:EXT:762:STATE")
  field(INPH, "YCOR:EXT:762:HSTA")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:EXT:762:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "YCOR:EXT:762:BLIMITS")
  field(LNK1, "YCOR:EXT:762:IACTLIMITS.F PP")
  field(DOL2, "YCOR:EXT:762:IACTLIMITS.I")
  field(LNK2, "YCOR:EXT:762:IACT.HIGH")
  field(DOL3, "YCOR:EXT:762:IACTLIMITS.J")
  field(LNK3, "YCOR:EXT:762:IACT.LOW")
  field(DOL4, "YCOR:EXT:762:IACTLIMITS.K")
  field(LNK4, "YCOR:EXT:762:IACT.HIHI")
  field(DOL5, "YCOR:EXT:762:IACTLIMITS.L")
  field(LNK5, "YCOR:EXT:762:IACT.LOLO")
  field(DOL6, "YCOR:EXT:762:BLIMITS")
  field(LNK6, "YCOR:EXT:762:IMONLIMITS.F PP")
  field(DOL7, "YCOR:EXT:762:IMONLIMITS.I")
  field(LNK7, "YCOR:EXT:762:IMON.HIGH")
  field(DOL8, "YCOR:EXT:762:IMONLIMITS.J")
  field(LNK8, "YCOR:EXT:762:IMON.LOW")
  field(DOL9, "YCOR:EXT:762:IMONLIMITS.K")
  field(LNK9, "YCOR:EXT:762:IMON.HIHI")
  field(DOLA, "YCOR:EXT:762:IMONLIMITS.L")
  field(LNKA, "YCOR:EXT:762:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "YCOR:EXT:762:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "YCOR:EXT:762:TRIMBTOL")
  field(INPE, "YCOR:EXT:762:CHCKBTOL")
  field(INPF, "YCOR:EXT:762:BDELTAS.K")
  field(INPG, "YCOR:EXT:762:BDELTAS.L")
  field(INPH, "YCOR:EXT:762:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "YCOR:EXT:762:STDZITOLR")
  field(INPC, "YCOR:EXT:762:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:202:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "YCOR:EXT:762:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:202:RESET PP
#
record(bo, "YCOR:EXT:762:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:202:RESET PP")
}

record(bo, "YCOR:EXT:762:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:202:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "YCOR:EXT:762:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "YCOR:EXT:762:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:202:IRAMPRATE PP")
  field(FLNK, "YCOR:EXT:762:STDZDLY")
}


record(ao, "YCOR:EXT:762:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:202:ISETPT PP")
  field(DOL, "YCOR:EXT:762:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "YCOR:EXT:762:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:202:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:EXT:762:BMON")
}

record(ao, "YCOR:EXT:762:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:202:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "YCOR:EXT:762:IRIPLOK")
}

record(sub, "YCOR:EXT:762:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "YCOR:EXT:762:IRIPL.VAL")
  field(INPB, "YCOR:EXT:762:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:EXT:762:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:EXT:762:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "YCOR:EXT:762:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:202:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "YCOR:EXT:762:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:202:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "YCOR:EXT:762:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:EXT:762:IACTPREVOK")
  field(LNK2, "YCOR:EXT:762:IDIFF")
  field(LNK3, "YCOR:EXT:762:IADIFF")
  field(LNK4, "YCOR:EXT:762:IRATIO")
  field(LNK5, "YCOR:EXT:762:IDIRECT")
  field(LNK6, "YCOR:EXT:762:IACTPOL_CHECK")
}

record(calc, "YCOR:EXT:762:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:EXT:762:IDES")
  field(INPB, "YCOR:EXT:762:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(calc, "YCOR:EXT:762:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "YCOR:EXT:762:IDIFF")
  field(PREC, "9")
}

record(calc, "YCOR:EXT:762:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:EXT:762:IDIFF")
  field(INPB, "YCOR:EXT:762:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "YCOR:EXT:762:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "YCOR:EXT:762:IMIN")
  field(INPB,   "YCOR:EXT:762:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "YCOR:EXT:762:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "YCOR:EXT:762:IACT")
  field(INPB, "YCOR:EXT:762:IDES")
  field(INPC, "YCOR:EXT:762:ISETPT")
  field(INPD, "YCOR:EXT:762:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "YCOR:EXT:762:IADJUST PP")
}

record(bo, "YCOR:EXT:762:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "YCOR:EXT:762:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "YCOR:EXT:762:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "YCOR:EXT:762:IACT")
  field(FLNK, "YCOR:EXT:762:IACTPOL")
}
record(bo, "YCOR:EXT:762:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:EXT:762:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"YCOR:EXT:762:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:EXT:762:IDELTAS and the\n  YCOR:EXT:762:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"YCOR:EXT:762:IACT: \n  Get copy of YCOR:EXT:762:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"YCOR:EXT:762:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"YCOR:EXT:762:IDES:\n  Contains raw value calculated by \nYCOR:EXT:762:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nYCOR:EXT:762:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"YCOR:EXT:762:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  YCOR:EXT:762:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               YCOR:EXT:762:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"YCOR:EXT:762:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by YCOR:EXT:762:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, YCOR:EXT:762:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  YCOR:EXT:762:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "YCOR:EXT:762:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:EXT:762:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:EXT:762:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:EXT:762:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:EXT:762:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "YCOR:EXT:762:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "YCOR:EXT:762:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "YCOR:EXT:762:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "YCOR:EXT:762:TRIMTYPE.RVAL")
  field(INPB,   "YCOR:EXT:762:CONFIG.RVAL")
  field(OUT,    "YCOR:EXT:762:TRIMMAXNUM PP")
}
record(longout, "YCOR:EXT:762:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "YCOR:EXT:762:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "YCOR:EXT:762:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "YCOR:EXT:762:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "YCOR:EXT:762:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "YCOR:EXT:762:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "YCOR:EXT:762:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "YCOR:EXT:762:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "YCOR:EXT:762:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "YCOR:EXT:762:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "YCOR:EXT:762:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "YCOR:EXT:762:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "YCOR:EXT:762:IMOVE")
 field(INPB, "YCOR:EXT:762:IACT")
 field(INPC, "YCOR:EXT:762:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "YCOR:EXT:762:TRIMDLYPCT")
 field(INPF, "YCOR:EXT:762:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "YCOR:EXT:762:RAMPTIME_LEFT PP")
}

record(longout, "YCOR:EXT:762:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "YCOR:EXT:762:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "YCOR:EXT:762:RAMPDONE_CALC")
}

record(calc, "YCOR:EXT:762:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "YCOR:EXT:762:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "YCOR:EXT:762:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "YCOR:EXT:762:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:EXT:762:RAMPTIME_LEFT")
 field(OUT,  "YCOR:EXT:762:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "YCOR:EXT:762:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:EXT:762:RAMPTIME_LEFT NMS")
 field(OUT,  "YCOR:EXT:762:RAMPDONE PP")
}

record(bo, "YCOR:EXT:762:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "YCOR:EXT:762:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "YCOR:EXT:762:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "YCOR:EXT:762:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:EXT:762:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "YCOR:EXT:762:DEBUG.PROC PP")
  field(LNK2, "YCOR:EXT:762:STDZCYCLENUM.PROC PP")
  field(LNK3, "YCOR:EXT:762:STDZDISABLE.PROC PP")
  field(LNK4, "YCOR:EXT:762:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "YCOR:EXT:762:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "YCOR:EXT:762:STDZIMIN NPP NMS")
  field(INPB, "YCOR:EXT:762:STDZIMAX NPP NMS")
  field(INPC, "YCOR:EXT:762:STDZIFINAL NPP NMS")
  field(INPD, "YCOR:EXT:762:STDZCYCLENUM NPP NMS")
  field(INPE, "YCOR:EXT:762:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "YCOR:EXT:762:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "YCOR:EXT:762:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "YCOR:EXT:762:STDZWF PP")
  field(OUTB, "YCOR:EXT:762:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "YCOR:EXT:762:STDZWF")
}

record(mbbo, "YCOR:EXT:762:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "YCOR:EXT:762:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "YCOR:EXT:762:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "YCOR:EXT:762:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "YCOR:EXT:762:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "YCOR:EXT:762:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "YCOR:EXT:762:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:EXT:762:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:EXT:762:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "YCOR:EXT:762:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "YCOR:EXT:762:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "YCOR:EXT:762:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "YCOR:EXT:762:STDZIMIN")
}

record(ao, "YCOR:EXT:762:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "YCOR:EXT:762:STDZIMAX")
}

record(ao, "YCOR:EXT:762:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "2")
  field(FLNK, "YCOR:EXT:762:STDZIFINAL")
}

record(ao, "YCOR:EXT:762:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "YCOR:EXT:762:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "YCOR:EXT:762:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "YCOR:EXT:762:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "YCOR:EXT:762:STDZIMIN CP NMS")
  field(INPB, "YCOR:EXT:762:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "YCOR:EXT:762:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "YCOR:EXT:762:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "YCOR:EXT:762:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "YCOR:EXT:762:STDZIMIN CP NMS")
  field(INPB, "YCOR:EXT:762:STDZIMAX CP NMS")
  field(INPC, "YCOR:EXT:762:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "YCOR:EXT:762:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "YCOR:EXT:762:TRIMDLYPCT CP MS")
  field(INPB, "YCOR:EXT:762:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "YCOR:EXT:762:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "YCOR:EXT:762:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:EXT:762:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "YCOR:EXT:762:IDES.HOPR")
  field(INPB, "YCOR:EXT:762:STDZMINIPCT CPP NMS")
  field(INPC, "YCOR:EXT:762:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "YCOR:EXT:762:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "YCOR:EXT:762:IDES.HOPR")
  field(INPB, "YCOR:EXT:762:IDES.LOPR")
  field(INPC, "YCOR:EXT:762:STDZDIRECT.RVAL")
  field(INPD, "YCOR:EXT:762:STDZMINIDELTA")
  field(INPE, "YCOR:EXT:762:IDES")
  field(PREC, "5")
  field(FLNK, "YCOR:EXT:762:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "YCOR:EXT:762:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "YCOR:EXT:762:IDES.HOPR")
  field(INPB, "YCOR:EXT:762:IDES.LOPR")
  field(INPC, "YCOR:EXT:762:STDZDIRECT.RVAL")
  field(INPD, "YCOR:EXT:762:STDZMINIDELTA")
  field(INPE, "YCOR:EXT:762:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "YCOR:EXT:762:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "YCOR:EXT:762:IADJUST.RVAL")
  field(INPB, "YCOR:EXT:762:STDZDIRECT.RVAL")
  field(INPC, "YCOR:EXT:762:STDZOK.RVAL")
  field(INPD, "YCOR:EXT:762:STDZDISABLE.RVAL")
  field(INPE, "YCOR:EXT:762:STATE.RVAL CPP NMS")
  field(INPF, "YCOR:EXT:762:ICTRL.RVAL")
  field(INPG, "YCOR:EXT:762:STATE.SEVR")
  field(INPH, "YCOR:EXT:762:BDELTAS.M")
  field(INPI, "YCOR:EXT:762:IACT.SEVR")
  field(OUT,  "YCOR:EXT:762:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "YCOR:EXT:762:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "YCOR:EXT:762:STDZLOSTTOD.PROC")
  field(LNK2, "YCOR:EXT:762:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "YCOR:EXT:762:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "YCOR:EXT:762:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:EXT:762:IACT CP")
  field(INPB, "YCOR:EXT:762:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "YCOR:EXT:762:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "YCOR:EXT:762:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "YCOR:EXT:762:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:EXT:762:STDZIACTMAX")
  field(INPB, "YCOR:EXT:762:IACT")
  field(INPC, "YCOR:EXT:762:IDELTAS.I")
  field(OUT,  "YCOR:EXT:762:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "YCOR:EXT:762:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "YCOR:EXT:762:STDZOK.RVAL CP")
  field(INPB, "YCOR:EXT:762:STDZDISABLE.RVAL CP")
  field(INPC, "YCOR:EXT:762:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "YCOR:EXT:762:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "YCOR:EXT:762:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "YCOR:EXT:762:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "YCOR:EXT:762:CALBOK")
  field(INPB, "YCOR:EXT:762:CALBDISABLE")
  field(INPC, "YCOR:EXT:762:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "YCOR:EXT:762:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "YCOR:EXT:762:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "YCOR:EXT:762:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "YCOR:EXT:762:CALBSLOPE")
  field(DOL3, "YCOR:EXT:762:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "YCOR:EXT:762:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:EXT:762:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "YCOR:EXT:762:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "YCOR:EXT:762:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "YCOR:EXT:762:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "YCOR:EXT:762:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "YCOR:EXT:762:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "YCOR:EXT:762:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "YCOR:EXT:762:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "YCOR:EXT:762:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "YCOR:EXT:762:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "YCOR:EXT:762:IACT")
  field(INPD, "YCOR:EXT:762:DACSLOPE")
  field(INPE, "YCOR:EXT:762:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "YCOR:EXT:762:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "YCOR:EXT:762:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "2")
  field(HOPR, "2")
  field(DRVL, "-2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "YCOR:EXT:762:CALBIMAX")
}

record(ao, "YCOR:EXT:762:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "2")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(VAL,  "2")
  field(FLNK, "YCOR:EXT:762:CALBSTEPNUM")
}

record(ao, "YCOR:EXT:762:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL, "0")
}

record(longout, "YCOR:EXT:762:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:EXT:762:CALBIDELTA")
}

record(calc, "YCOR:EXT:762:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "YCOR:EXT:762:CALBIMAX")
  field(INPB, "YCOR:EXT:762:CALBIMIN")
  field(INPC, "YCOR:EXT:762:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "YCOR:EXT:762:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:202:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:202:IACT.HOPR")
  field(INPC, "YCOR:EXT:762:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "YCOR:EXT:762:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:EXT:762:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:EXT:762:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:EXT:762:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:EXT:762:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "YCOR:EXT:762:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:EXT:762:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:EXT:762:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:EXT:762:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "YCOR:EXT:762:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:EXT:762:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:EXT:762:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:EXT:762:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:EXT:762:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:EXT:762:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:EXT:762:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "YCOR:EXT:762:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:EXT:762:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "YCOR:EXT:762:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "YCOR:EXT:762:CALBSTEPNUM")
  field(INPB, "YCOR:EXT:762:CALBIACTWF")
  field(INPC, "YCOR:EXT:762:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "YCOR:EXT:762:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "YCOR:EXT:762:STDZITOL")

  field(INPH, "YCOR:EXT:762:DACSLOPE")
  field(INPI, "YCOR:EXT:762:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "YCOR:EXT:762:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "YCOR:EXT:762:CALBSTEPNUM")
  field(INPB, "YCOR:EXT:762:CALBIACTWF")
  field(INPC, "YCOR:EXT:762:DACWF")
  field(INPF, "YCOR:EXT:762:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe YCOR:EXT:762CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "YCOR:EXT:762:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "YCOR:EXT:762:DEGAUSIMIN.PROC PP")
  field(OUTB, "YCOR:EXT:762:DEGAUSIMAX.PROC PP")
  field(OUTC, "YCOR:EXT:762:DEGAUSTYPE.PROC PP")
  field(OUTD, "YCOR:EXT:762:DEGAUSSTEP.PROC PP")
  field(OUTE, "YCOR:EXT:762:MADNAME.PROC PP")
  field(OUTF, "YCOR:EXT:762:PSTYPE.PROC PP")
  field(OUTG, "YCOR:EXT:762:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "YCOR:EXT:762:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:EXT:762:DEGAUSIMIN NPP NMS")
  field(INPB, "YCOR:EXT:762:DEGAUSIMAX NPP NMS")
  field(INPC, "YCOR:EXT:762:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "YCOR:EXT:762:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "YCOR:EXT:762:PSTYPE NPP NMS")
  field(INPG, "YCOR:EXT:762:DEBUG.RVAL NPP NMS")
  field(INPH, "YCOR:EXT:762:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "YCOR:EXT:762:DEGAUSWF PP")
  field(OUTB, "YCOR:EXT:762:DEGAUSMSG PP")
  field(OUTC, "YCOR:EXT:762:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "YCOR:EXT:762:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"YCOR:EXT:762:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "YCOR:EXT:762:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "YCOR:EXT:762:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "YCOR:EXT:762:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "YCOR:EXT:762:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "YCOR:EXT:762:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "-2")
}
record(ao, "YCOR:EXT:762:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"YCOR:EXT:762:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "YCOR:EXT:762:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"YCOR:EXT:762:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "YCOR:EXT:762:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "YCOR:EXT:762:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "YCOR:EXT:762:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "YCOR:EXT:762:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:EXT:762:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:EXT:762:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:EXT:762:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:EXT:762:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "YCOR:EXT:762:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "YCOR:EXT:762:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "YCOR:EXT:762:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "YCOR:EXT:762:DEGAUS_IMAX")
  field(INPB, "YCOR:EXT:762:ISETPT")
  field(INPC, "YCOR:EXT:762:DEGAUSTYPE.RVAL")
  field(OUT,  "YCOR:EXT:762:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "YCOR:EXT:762:DEGAUS_IMAX_UPDATE")
}
record(seq, "YCOR:EXT:762:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "YCOR:EXT:762:ISETPT")
  field(LNK1, "YCOR:EXT:762:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "YCOR:EXT:762:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
  field(FLNK, "YCOR:EXT:762:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "YCOR:EXT:762:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "YCOR:EXT:762:DEGAUS_IMAX")
  field(FLNK, "YCOR:EXT:762:DEGAUS_IMAXPOL")
}
record(bo, "YCOR:EXT:762:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:EXT:762:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "YCOR:EXT:762:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "YCOR:EXT:762:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "YCOR:EXT:762:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "YCOR:EXT:762:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "YCOR:EXT:762:IACT")
  field(INPB, "YCOR:EXT:762:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "YCOR:EXT:762:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "YCOR:EXT:762:IACTPOL")
}
record(bo, "YCOR:EXT:762:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"YCOR:EXT:762:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "YCOR:EXT:762:DEGAUSENABLE CP")
  field(INPB, "YCOR:EXT:762:DEGAUSOK")
  field(INPC, "YCOR:EXT:762:STATE CP")
  field(INPD, "YCOR:EXT:762:STATE.SEVR")
  field(OUT,  "YCOR:EXT:762:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "YCOR:EXT:762:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "YCOR:EXT:762:DEGAUS_STATE_CHECK")
  field(LNK1, "YCOR:EXT:762:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "YCOR:EXT:762:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "YCOR:EXT:762:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "YCOR:EXT:762:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "YCOR:EXT:762:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "YCOR:EXT:762:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:EXT:762:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "YCOR:EXT:762:STATMSG.FRSV")
  field(LNK4, "YCOR:EXT:762:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:EXT:762:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "YCOR:EXT:762:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:EXT:762:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "YCOR:EXT:762:STATMSG.FRSV")
  field(LNK4, "YCOR:EXT:762:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:EXT:762:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "YCOR:EXT:762:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "YCOR:EXT:762:STATMSG.FRSV")
  field(LNK3, "YCOR:EXT:762:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "YCOR:EXT:762:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "YCOR:EXT:762:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "YCOR:EXT:762:STATMSG.FRSV PP")
  field(LNK3, "YCOR:EXT:762:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "YCOR:EXT:762:FUNC") {
  field(DESC, "YCOR:EXT:762 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "YCOR:EXT:762:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:EXT:762:CTRL") {
  field(DESC, "YCOR:EXT:762 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "YCOR:EXT:762:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "YCOR:EXT:762:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "YCOR:EXT:762:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "YCOR:EXT:762:BUSY") {
  field(DESC, "YCOR:EXT:762 Ctrl Done")
  field(DOL, "YCOR:EXT:762:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "YCOR:EXT:762:SELECT")
}

record(bo, "YCOR:EXT:762:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "YCOR:EXT:762:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:EXT:762:CTRLSTATE") {
  field(DESC, "YCOR:EXT:762 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("YCOR:EXT:762:CTRL",20,20,0,0,"YCOR:EXT:762:CTRL")
#! Field("YCOR:EXT:762:CTRL.OUT",16777215,1,"YCOR:EXT:762:CTRL.OUT")
#! Link("YCOR:EXT:762:CTRL.OUT","YCOR:EXT:762:SELECTEN.A")
#! Field("YCOR:EXT:762:CTRL.VAL",16777215,1,"YCOR:EXT:762:CTRL.VAL")
#! Record("YCOR:EXT:762:SELECTEN",321,381,0,0,"YCOR:EXT:762:SELECTEN")
#! Field("YCOR:EXT:762:SELECTEN.A",16777215,0,"YCOR:EXT:762:SELECTEN.A")
#! Field("YCOR:EXT:762:SELECTEN.FLNK",16777215,1,"YCOR:EXT:762:SELECTEN.FLNK")
#! Link("YCOR:EXT:762:SELECTEN.FLNK","YCOR:EXT:762:BUSY")
#! Field("YCOR:EXT:762:SELECTEN.VAL",16777215,1,"YCOR:EXT:762:SELECTEN.VAL")
#! Record("YCOR:EXT:762:BUSY",623,274,0,0,"YCOR:EXT:762:BUSY")
#! Field("YCOR:EXT:762:BUSY.DOL",16777215,0,"YCOR:EXT:762:BUSY.DOL")
#! Link("YCOR:EXT:762:BUSY.DOL","YCOR:EXT:762:SELECTEN.VAL")
#! Field("YCOR:EXT:762:BUSY.FLNK",16777215,1,"YCOR:EXT:762:BUSY.FLNK")
#! Link("YCOR:EXT:762:BUSY.FLNK","YCOR:EXT:762:SELECT")
#! Record("YCOR:EXT:762:SELECT",669,508,0,1,"YCOR:EXT:762:SELECT")
#! Record("YCOR:EXT:762:FUNC",940,120,0,0,"YCOR:EXT:762:FUNC")
#! Field("YCOR:EXT:762:FUNC.OUT",16777215,0,"YCOR:EXT:762:FUNC.OUT")
#! Link("YCOR:EXT:762:FUNC.OUT","YCOR:EXT:762:CTRL.VAL")
#! Record("YCOR:EXT:762:ABORT",193,41,0,0,"YCOR:EXT:762:ABORT")
#! Record("YCOR:EXT:762:CTRLSTATE",369,34,0,0,"YCOR:EXT:762:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"YCOR:EXT:762:SELECT is used for Multi-device selection.\nIt is enabled when associated YCOR:EXT:762:CTRL is \"0\" (DONE).\nIt is disabled when associated YCOR:EXT:762:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"YCOR:EXT:762:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "YCOR:EXT:762:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "YCOR:EXT:762:BCTRL.SEVR")
  field(OUT,  "YCOR:EXT:762:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "YCOR:EXT:762:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:EXT:762:BACT")
  field(INPB, "YCOR:EXT:762:POLYCOEF")
  field(INPC, "YCOR:EXT:762:POLYCOEF.A")
  field(INPD, "YCOR:EXT:762:POLYCOEF.B")
  field(INPE, "YCOR:EXT:762:IACT MS")
  field(INPF, "YCOR:EXT:762:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
  field(FLNK, "YCOR:EXT:762:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "YCOR:EXT:762:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:EXT:762:BDES")
  field(INPB, "YCOR:EXT:762:TRIMBTOL")
  field(INPC, "YCOR:EXT:762:TRIMBTOLR")
  field(INPD, "YCOR:EXT:762:CHCKBTOL")
  field(INPE, "YCOR:EXT:762:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "YCOR:EXT:762:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "YCOR:EXT:762:MPSBTOL")
  field(INPQ, "YCOR:EXT:762:MPSBTOLR")
  field(FLNK, "YCOR:EXT:762:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "YCOR:EXT:762:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "YCOR:EXT:762:BDES")
  field(INPB, "YCOR:EXT:762:BDELTAS.I")
  field(INPG, "YCOR:EXT:762:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "YCOR:EXT:762:BCON.HIGH")
  field(OUTB, "YCOR:EXT:762:BCON.LOW")
  field(OUTC, "YCOR:EXT:762:BCON.HIHI")
  field(OUTD, "YCOR:EXT:762:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:EXT:762:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "YCOR:EXT:762:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:EXT:762:BDIFF")
  field(LNK2, "YCOR:EXT:762:BADIFF")
  field(LNK3, "YCOR:EXT:762:BRATIO")
  field(LNK4, "YCOR:EXT:762:MPSLIMITS")
  field(LNK5, "YCOR:EXT:762:I2BSTATUS")
  field(LNK6, "YCOR:EXT:762:IACTFO.PROC")
}

record(calc, "YCOR:EXT:762:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:EXT:762:BDES")
  field(INPB, "YCOR:EXT:762:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "YCOR:EXT:762:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "YCOR:EXT:762:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "YCOR:EXT:762:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:EXT:762:BDIFF")
  field(INPB, "YCOR:EXT:762:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "YCOR:EXT:762:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "YCOR:EXT:762:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "YCOR:EXT:762:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:EXT:762:BMON")
  field(INPB, "YCOR:EXT:762:POLYCOEF")
  field(INPC, "YCOR:EXT:762:POLYCOEF.A")
  field(INPD, "YCOR:EXT:762:POLYCOEF.B")
  field(INPE, "YCOR:EXT:762:IMON MS")
  field(INPF, "YCOR:EXT:762:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:202:BDES CP
record(ao,  "YCOR:EXT:762:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.02098636")
   field(DRVL, "-0.02098636")
   field(HOPR, "0.02098636")
   field(LOPR, "-0.02098636")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "YCOR:EXT:762:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "YCOR:EXT:762:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:EXT:762:POLYCOEF")
  field(INPC, "YCOR:EXT:762:POLYCOEF.A")
  field(INPD, "YCOR:EXT:762:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "YCOR:EXT:762:BDES.DRVH")
  field(INPF, "YCOR:EXT:762:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:EXT:762:IDES")
}
record(sub, "YCOR:EXT:762:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:EXT:762:POLYCOEF")
  field(INPC, "YCOR:EXT:762:POLYCOEF.A")
  field(INPD, "YCOR:EXT:762:POLYCOEF.B")
  field(INPE, "YCOR:EXT:762:BDES.DRVH")
  field(INPF, "YCOR:EXT:762:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "YCOR:EXT:762:INOM")
}

record(sub, "YCOR:EXT:762:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:EXT:762:BDES.VAL")
  field(INPB, "YCOR:EXT:762:BDES.DRVH")
  field(INPC, "YCOR:EXT:762:BDES.DRVL")
  field(INPD, "YCOR:EXT:762:BDELTAS.I")
  field(INPE, "YCOR:EXT:762:BDELTAS.J")
  field(INPG, "YCOR:EXT:762:STATE")
  field(INPH, "YCOR:EXT:762:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:EXT:762:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:EXT:762:BDES.VAL")
  field(INPB, "YCOR:EXT:762:BDES.DRVH")
  field(INPC, "YCOR:EXT:762:BDES.DRVL")
  field(INPD, "YCOR:EXT:762:BDELTAS.K")
  field(INPE, "YCOR:EXT:762:BDELTAS.L")
  field(INPG, "YCOR:EXT:762:STATE")
  field(INPH, "YCOR:EXT:762:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:EXT:762:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "YCOR:EXT:762:BLIMITS")
  field(LNK1, "YCOR:EXT:762:BACTLIMITS.F PP")
  field(DOL2, "YCOR:EXT:762:BACTLIMITS.I")
  field(LNK2, "YCOR:EXT:762:BACT.HIGH")
  field(DOL3, "YCOR:EXT:762:BACTLIMITS.J")
  field(LNK3, "YCOR:EXT:762:BACT.LOW")
  field(DOL4, "YCOR:EXT:762:BACTLIMITS.K")
  field(LNK4, "YCOR:EXT:762:BACT.HIHI")
  field(DOL5, "YCOR:EXT:762:BACTLIMITS.L")
  field(LNK5, "YCOR:EXT:762:BACT.LOLO")
  field(DOL6, "YCOR:EXT:762:BLIMITS")
  field(LNK6, "YCOR:EXT:762:BMONLIMITS.F PP")
  field(DOL7, "YCOR:EXT:762:BMONLIMITS.I")
  field(LNK7, "YCOR:EXT:762:BMON.HIGH")
  field(DOL8, "YCOR:EXT:762:BMONLIMITS.J")
  field(LNK8, "YCOR:EXT:762:BMON.LOW")
  field(DOL9, "YCOR:EXT:762:BMONLIMITS.K")
  field(LNK9, "YCOR:EXT:762:BMON.HIHI")
  field(DOLA, "YCOR:EXT:762:BMONLIMITS.L")
  field(LNKA, "YCOR:EXT:762:BMON.LOLO")
  field(FLNK, "YCOR:EXT:762:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "YCOR:EXT:762:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "YCOR:EXT:762:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "YCOR:EXT:762:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "YCOR:EXT:762:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "YCOR:EXT:762:BCTRL.VAL")
  field(LNK2, "YCOR:EXT:762:BDES PP")

  field(DOL3, "1")
  field(LNK3, "YCOR:EXT:762:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "YCOR:EXT:762:CHECKSTDZLOST.PROC PP")

  field(DOL5, "YCOR:EXT:762:BCTRL.VAL")
  field(LNK5, "YCOR:EXT:762:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "YCOR:EXT:762:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "YCOR:EXT:762:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:EXT:762:POLYCOEF")
  field(INPC, "YCOR:EXT:762:POLYCOEF.A")
  field(INPD, "YCOR:EXT:762:POLYCOEF.B")
  field(INPE, "YCOR:EXT:762:BDES.DRVH")
  field(INPF, "YCOR:EXT:762:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:EXT:762:ISETPT")
}

record(ao, "YCOR:EXT:762:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "YCOR:EXT:762:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "YCX02")
}

record(ai, "YCOR:EXT:762:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "658.8759")
}

record(ao, "YCOR:EXT:762:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(FLNK, "YCOR:EXT:762:BSTEP")
}

record(ao, "YCOR:EXT:762:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(FLNK, "YCOR:EXT:762:BSTEP")
}

record(ao, "YCOR:EXT:762:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by YCOR:EXT:762:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "YCOR:EXT:762:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "YCOR:EXT:762:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "YCOR:EXT:762:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:EXT:762:POLYCOEF")
  field(INPC, "YCOR:EXT:762:POLYCOEF.A")
  field(INPD, "YCOR:EXT:762:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "YCOR:EXT:762:BCON.DRVH")
  field(INPF, "YCOR:EXT:762:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:EXT:762:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "YCOR:EXT:762:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "YCOR:EXT:762:BMAX")
  field(INPB, "YCOR:EXT:762:BMIN")
  field(INPC, "YCOR:EXT:762:BMIN.SEVR")
  field(INPD, "YCOR:EXT:762:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"YCOR:EXT:762:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "YCOR:EXT:762:ONLINE CP")
  field(OUT,  "YCOR:EXT:762:BCTRLDISABLEFOUT PP")
}

record(fanout, "YCOR:EXT:762:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "YCOR:EXT:762:BCTRLDISABLECALC")
  field(LNK1, "YCOR:EXT:762:BCTRLDISABLE")
  field(LNK2, "YCOR:EXT:762:BCTRLENABLE")
}

record(stringout, "YCOR:EXT:762:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:EXT:762:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "YCOR:EXT:762:BCTRLDISV_UPDATE")
}

record(stringout, "YCOR:EXT:762:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:EXT:762:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "YCOR:EXT:762:BCTRLDISV_UPDATE")
}

record(calcout, "YCOR:EXT:762:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "YCOR:EXT:762:ONLINE")
  field(OUT,  "YCOR:EXT:762:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"YCOR:EXT:762:BACT and MON\n  are processed via links from \n  YCOR:EXT:762:IACT (device raw value readback 1)\n  and\n  YCOR:EXT:762:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from YCOR:EXT:762:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = YCOR:EXT:762:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"YCOR:EXT:762:BDES\n  is processed when set by CA users or \n  YCOR:EXT:762:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"YCOR:EXT:762:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  YCOR:EXT:762:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (YCOR:EXT:762:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"YCOR:EXT:762:B*LIMITS and YCOR:EXT:762:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:EXT:762:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"YCOR:EXT:762:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"YCOR:EXT:762:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "YCOR:EXT:762:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:EXT:762:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "YCOR:EXT:762:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "YCOR:EXT:762:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:EXT:762:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:EXT:762:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:EXT:762:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "YCOR:EXT:762:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "YCOR:EXT:762:MPSLIMITS.E PP")
}

record(aSub, "YCOR:EXT:762:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "YCOR:EXT:762:MPS.RVAL")
  field(INPB, "YCOR:EXT:762:BADIFF")
  field(INPC, "YCOR:EXT:762:BDELTAS.N")
  field(INPD, "YCOR:EXT:762:BACT")
  field(INPE, "YCOR:EXT:762:MPSBITMASK.RVAL")
  field(INPF, "YCOR:EXT:762:MPSBLLIM")
  field(INPG, "YCOR:EXT:762:MPSBMIN")
  field(INPH, "YCOR:EXT:762:MPSBMAX")
  field(INPI, "YCOR:EXT:762:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "YCOR:EXT:762:INTOL.RVAL PP")
  field(OUTB, "YCOR:EXT:762:INTOL_BMIN.RVAL PP")
  field(OUTC, "YCOR:EXT:762:INTOL_BRANGE.RVAL PP")
  field(OUTD, "YCOR:EXT:762:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "YCOR:EXT:762:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:EXT:762:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:EXT:762:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:EXT:762:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:EXT:762:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:EXT:762:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:EXT:762:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:EXT:762:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "YCOR:EXT:762:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "YCOR:EXT:762:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:EXT:762:CHCKBTOL")
  field(INPB, "YCOR:EXT:762:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "YCOR:EXT:762:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "YCOR:EXT:762:CHCKBTOL")
  field(FLNK, "YCOR:EXT:762:CHCKITOL")
}

record(calc, "YCOR:EXT:762:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "YCOR:EXT:762:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "YCOR:EXT:762:BDES.HOPR")
  field(INPB, "YCOR:EXT:762:STABILITY")
  field(INPC, "YCOR:EXT:762:BDES.LOPR")
}

record(longout, "YCOR:EXT:762:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "YCOR:EXT:762:CHCKBTOL")
}

record(calc, "YCOR:EXT:762:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:EXT:762:POLYCOEF.B")
  field(INPB, "YCOR:EXT:762:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "YCOR:EXT:762:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "YCOR:EXT:762:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "YCOR:EXT:762:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "YCOR:EXT:762:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "YCOR:EXT:762:PAUGO")  
}

record(fanout, "YCOR:EXT:762:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "YCOR:EXT:762:PAUSTOP")
  field(LNK2, "YCOR:EXT:762:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "YCOR:EXT:762:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "YCOR:EXT:762:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:202:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:202:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "YCOR:EXT:762:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "YCOR:EXT:762:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:202:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:202:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "YCOR:EXT:762:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:202:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:EXT:762:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "YCOR:EXT:762:PSTYPE.RVAL")
  field(INPC, "YCOR:EXT:762:TURNEDOFF.RVAL")
  field(INPD, "YCOR:EXT:762:CONFIG.RVAL")
  field(INPE, "YCOR:EXT:762:PSCATEGORY.RVAL")
  field(INPF, "YCOR:EXT:762:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "YCOR:EXT:762:AUTOCTRL.RVAL")
  field(INPJ, "YCOR:EXT:762:OUTOFSERVICE.RVAL")
  field(INPL, "YCOR:EXT:762:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "YCOR:EXT:762:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "YCOR:EXT:762:PAU")
  field(INPP, "YCOR:EXT:762:CALBDISABLE.RVAL")
  field(INPQ, "YCOR:EXT:762:PTRBDISABLE.RVAL")
  field(INPR, "YCOR:EXT:762:TRIMDISABLE.RVAL")
  field(INPS, "YCOR:EXT:762:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "YCOR:EXT:762:FBCK")
  field(INPU, "YCOR:EXT:762:TRIMTYPE.RVAL")
  field(INPV, "YCOR:EXT:762:STDZDIRECT.RVAL")
  field(INPW, "YCOR:EXT:762:DEGAUSENABLE.RVAL")
  field(FLNK, "YCOR:EXT:762:HSTA")
}

record(longin, "YCOR:EXT:762:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "YCOR:EXT:762:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "YCOR:EXT:762:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "YCOR:EXT:762:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "YCOR:EXT:762:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:EXT:762:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:EXT:762:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:EXT:762:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by YCOR:EXT:762:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses YCOR:EXT:762:FBCK.
# This PV should be replaced by YCOR:EXT:762:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "YCOR:EXT:762:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "YCOR:EXT:762:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:EXT:762:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:EXT:762:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"YCOR:EXT:762:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "YCOR:EXT:762:OUTOFSERVICE NPP NMS")
  field(OUT,  "YCOR:EXT:762:ONLINE PP")
}
record(bo, "YCOR:EXT:762:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "YCOR:EXT:762:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:EXT:762:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "YCOR:EXT:762:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "YCOR:EXT:762:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "YCOR:EXT:762:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "YCOR:EXT:762:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "YCOR:EXT:762:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "YCOR:EXT:762:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:EXT:762:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:EXT:762:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:EXT:762:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "YCOR:EXT:762:TRIMTYPE")
}

record(stringout, "YCOR:EXT:762:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "YCOR:EXT:762:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "YCOR:EXT:762:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "YCOR:EXT:762:STATE.RVAL")
  field(INPB, "YCOR:EXT:762:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:EXT:762:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:EXT:762:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "YCOR:EXT:762:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "YCOR:EXT:762:STATE.RVAL")
  field(INPB, "YCOR:EXT:762:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:EXT:762:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:EXT:762:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "YCOR:EXT:762:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "YCOR:EXT:762:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "YCOR:EXT:762:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "YCOR:EXT:762:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "YCOR:EXT:762:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"YCOR:EXT:762:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("YCOR:EXT:762:TURNEDOFF",3140,1907,0,1,"YCOR:EXT:762:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:EXT:762:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "YCOR:EXT:762:BACT.STAT")
  field(INPB, "YCOR:EXT:762:BDES.STAT")
  field(INPC, "YCOR:EXT:762:IRIPL.STAT")
  field(INPD, "MCOR:EXT:202:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:202:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "YCOR:EXT:762:BACT.SEVR")
  field(INPH, "YCOR:EXT:762:BDES.SEVR")
  field(INPI, "YCOR:EXT:762:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:202:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:202:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "YCOR:EXT:762:STATE.RVAL")
  field(INPN, "YCOR:EXT:762:STDZOK")
  field(INPO, "YCOR:EXT:762:CALBOK")
  field(INPP, "YCOR:EXT:762:OUTOFSERVICE.RVAL")
  field(INPQ, "YCOR:EXT:762:CONFIG.RVAL")
  field(INPR, "YCOR:EXT:762:HSTA")
  field(INPS, "YCOR:EXT:762:CTRL.RVAL")
  field(INPT, "YCOR:EXT:762:DEGAUSOK") 
  field(INPV, "YCOR:EXT:762:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "YCOR:EXT:762:STAT")
}

record(longout, "YCOR:EXT:762:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "YCOR:EXT:762:STATCTRLSUB")
  field(DOL, "YCOR:EXT:762:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "YCOR:EXT:762:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "YCOR:EXT:762:STAT")
  field(INPB, "YCOR:EXT:762:HSTA")
  field(INPD, "YCOR:EXT:762:ONOFFCTRL.RVAL")
  field(FLNK, "YCOR:EXT:762:STATMSG")
}

record(mbbo, "YCOR:EXT:762:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:EXT:762:UNAVAILGO")
  field(DOL, "YCOR:EXT:762:STATCTRLSUB.W")
}

record(seq, "YCOR:EXT:762:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "YCOR:EXT:762:STATSUB.U")
  field(LNK1, "YCOR:EXT:762:UNAVAIL PP")
}

record(stringout, "YCOR:EXT:762:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"YCOR:EXT:762:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - YCOR:EXT:762:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - YCOR:EXT:762:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"YCOR:EXT:762STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - YCOR:EXT:762:STATUS\nC - YCOR:EXT:762:ON\nD - YCOR:EXT:762:STDZOK\nE - YCOR:EXT:762:CALBOK\nF - YCOR:EXT:762:BACTDRIFT (future)\nG -\nH- YCOR:EXT:762:DACSTATUS\nI -YCOR:EXT:762:ADCSTATUS\nJ - YCOR:EXT:762:BACTSTATUS\nK - YCOR:EXT:762:BDESSTATUS\nL - YCOR:EXT:762:RIPLSTATUS\n\nOutput:\nP - YCOR:EXT:762:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "YCOR:EXT:762:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "YCOR:EXT:762:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "YCOR:EXT:762:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "YCOR:EXT:762:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "YCOR:DOG:113:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:203:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:DOG:113:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "YCOR:DOG:113:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:203:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "YCOR:DOG:113:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "6")
  field(LOLO, "-6")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "YCOR:DOG:113:BDELTAS")
  field(DRVH, "6")
  field(DRVL, "-6")
  field(DOL,  "YCOR:DOG:113:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "YCOR:DOG:113:ICTRL PP")
}

# This record is processed by YCOR:DOG:113:ICON")
# Note: we are not setting alarms here.
record(ao, "YCOR:DOG:113:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(DRVH, "6")
  field(DRVL, "-6")
  field(DOL,  "YCOR:DOG:113:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:113:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "YCOR:DOG:113:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "6")
  field(DRVL, "-6")
  field(HOPR, "6")
  field(LOPR, "-6")
}

record(ao, "YCOR:DOG:113:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(DRVH, "6")
  field(DRVL, "-6")
  field(MDEL, "-1")
  field(FLNK, "YCOR:DOG:113:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "YCOR:DOG:113:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "YCOR:DOG:113:ISETPT.OMSL")

  field(DOL2, "YCOR:DOG:113:ICTRL")
  field(LNK2, "YCOR:DOG:113:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "YCOR:DOG:113:ISETPT.OMSL")
}

record(ao, "YCOR:DOG:113:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "6")
  field(DRVL, "-6")
  field(EGU,  "A")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "6")
  field(FLNK, "YCOR:DOG:113:IMIN")
}

record(ao, "YCOR:DOG:113:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "6")
  field(DRVL, "-6")
  field(EGU,  "A")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(PREC, "3")
  field(VAL,  "-6")
  field(FLNK, "YCOR:DOG:113:IRANGE")
}

record(sel, "YCOR:DOG:113:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(PREC, "3")
  field(NVL,  "YCOR:DOG:113:BACT.SEVR")
  field(INPA, "YCOR:DOG:113:IACT NPP MS")
  field(INPB, "YCOR:DOG:113:IACTPREVOK NPP MS")
  field(INPC, "YCOR:DOG:113:IACTPREVOK NPP MS")
  field(INPD, "YCOR:DOG:113:IACTPREVOK NPP MS")
}

record(sub, "YCOR:DOG:113:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:113:IDES")
  field(INPB, "YCOR:DOG:113:ISETPT.DRVH")
  field(INPC, "YCOR:DOG:113:ISETPT.DRVL")
  field(INPD, "YCOR:DOG:113:IDELTAS.I")
  field(INPE, "YCOR:DOG:113:IDELTAS.J")
  field(INPG, "YCOR:DOG:113:STATE")
  field(INPH, "YCOR:DOG:113:HSTA")
  field(EGU,  "A")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:DOG:113:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:113:IDES")
  field(INPB, "YCOR:DOG:113:ISETPT.DRVH")
  field(INPC, "YCOR:DOG:113:ISETPT.DRVL")
  field(INPD, "YCOR:DOG:113:IDELTAS.K")
  field(INPE, "YCOR:DOG:113:IDELTAS.L")
  field(INPG, "YCOR:DOG:113:STATE")
  field(INPH, "YCOR:DOG:113:HSTA")
  field(EGU, "A")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:DOG:113:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "YCOR:DOG:113:BLIMITS")
  field(LNK1, "YCOR:DOG:113:IACTLIMITS.F PP")
  field(DOL2, "YCOR:DOG:113:IACTLIMITS.I")
  field(LNK2, "YCOR:DOG:113:IACT.HIGH")
  field(DOL3, "YCOR:DOG:113:IACTLIMITS.J")
  field(LNK3, "YCOR:DOG:113:IACT.LOW")
  field(DOL4, "YCOR:DOG:113:IACTLIMITS.K")
  field(LNK4, "YCOR:DOG:113:IACT.HIHI")
  field(DOL5, "YCOR:DOG:113:IACTLIMITS.L")
  field(LNK5, "YCOR:DOG:113:IACT.LOLO")
  field(DOL6, "YCOR:DOG:113:BLIMITS")
  field(LNK6, "YCOR:DOG:113:IMONLIMITS.F PP")
  field(DOL7, "YCOR:DOG:113:IMONLIMITS.I")
  field(LNK7, "YCOR:DOG:113:IMON.HIGH")
  field(DOL8, "YCOR:DOG:113:IMONLIMITS.J")
  field(LNK8, "YCOR:DOG:113:IMON.LOW")
  field(DOL9, "YCOR:DOG:113:IMONLIMITS.K")
  field(LNK9, "YCOR:DOG:113:IMON.HIHI")
  field(DOLA, "YCOR:DOG:113:IMONLIMITS.L")
  field(LNKA, "YCOR:DOG:113:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "YCOR:DOG:113:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "YCOR:DOG:113:TRIMBTOL")
  field(INPE, "YCOR:DOG:113:CHCKBTOL")
  field(INPF, "YCOR:DOG:113:BDELTAS.K")
  field(INPG, "YCOR:DOG:113:BDELTAS.L")
  field(INPH, "YCOR:DOG:113:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "YCOR:DOG:113:STDZITOLR")
  field(INPC, "YCOR:DOG:113:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:203:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "YCOR:DOG:113:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:203:RESET PP
#
record(bo, "YCOR:DOG:113:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:203:RESET PP")
}

record(bo, "YCOR:DOG:113:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:203:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "YCOR:DOG:113:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "YCOR:DOG:113:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:203:IRAMPRATE PP")
  field(FLNK, "YCOR:DOG:113:STDZDLY")
}


record(ao, "YCOR:DOG:113:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(DRVH, "6")
  field(DRVL, "-6")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:203:ISETPT PP")
  field(DOL, "YCOR:DOG:113:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "YCOR:DOG:113:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:203:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:DOG:113:BMON")
}

record(ao, "YCOR:DOG:113:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:203:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "YCOR:DOG:113:IRIPLOK")
}

record(sub, "YCOR:DOG:113:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "YCOR:DOG:113:IRIPL.VAL")
  field(INPB, "YCOR:DOG:113:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:DOG:113:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:DOG:113:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "YCOR:DOG:113:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:203:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "YCOR:DOG:113:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:203:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "YCOR:DOG:113:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:DOG:113:IACTPREVOK")
  field(LNK2, "YCOR:DOG:113:IDIFF")
  field(LNK3, "YCOR:DOG:113:IADIFF")
  field(LNK4, "YCOR:DOG:113:IRATIO")
  field(LNK5, "YCOR:DOG:113:IDIRECT")
  field(LNK6, "YCOR:DOG:113:IACTPOL_CHECK")
}

record(calc, "YCOR:DOG:113:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:DOG:113:IDES")
  field(INPB, "YCOR:DOG:113:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "6")
  field(LOPR, "-6")
}

record(calc, "YCOR:DOG:113:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "YCOR:DOG:113:IDIFF")
  field(PREC, "9")
}

record(calc, "YCOR:DOG:113:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:DOG:113:IDIFF")
  field(INPB, "YCOR:DOG:113:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "YCOR:DOG:113:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "YCOR:DOG:113:IMIN")
  field(INPB,   "YCOR:DOG:113:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "YCOR:DOG:113:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "YCOR:DOG:113:IACT")
  field(INPB, "YCOR:DOG:113:IDES")
  field(INPC, "YCOR:DOG:113:ISETPT")
  field(INPD, "YCOR:DOG:113:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "YCOR:DOG:113:IADJUST PP")
}

record(bo, "YCOR:DOG:113:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "YCOR:DOG:113:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "YCOR:DOG:113:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "YCOR:DOG:113:IACT")
  field(FLNK, "YCOR:DOG:113:IACTPOL")
}
record(bo, "YCOR:DOG:113:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:DOG:113:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"YCOR:DOG:113:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:DOG:113:IDELTAS and the\n  YCOR:DOG:113:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"YCOR:DOG:113:IACT: \n  Get copy of YCOR:DOG:113:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"YCOR:DOG:113:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"YCOR:DOG:113:IDES:\n  Contains raw value calculated by \nYCOR:DOG:113:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nYCOR:DOG:113:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"YCOR:DOG:113:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  YCOR:DOG:113:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               YCOR:DOG:113:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"YCOR:DOG:113:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by YCOR:DOG:113:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, YCOR:DOG:113:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  YCOR:DOG:113:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "YCOR:DOG:113:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:113:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:DOG:113:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:DOG:113:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:DOG:113:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "YCOR:DOG:113:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "YCOR:DOG:113:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "YCOR:DOG:113:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "YCOR:DOG:113:TRIMTYPE.RVAL")
  field(INPB,   "YCOR:DOG:113:CONFIG.RVAL")
  field(OUT,    "YCOR:DOG:113:TRIMMAXNUM PP")
}
record(longout, "YCOR:DOG:113:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "YCOR:DOG:113:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "YCOR:DOG:113:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "YCOR:DOG:113:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "YCOR:DOG:113:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "YCOR:DOG:113:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "YCOR:DOG:113:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "YCOR:DOG:113:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "YCOR:DOG:113:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "YCOR:DOG:113:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "YCOR:DOG:113:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "YCOR:DOG:113:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "YCOR:DOG:113:IMOVE")
 field(INPB, "YCOR:DOG:113:IACT")
 field(INPC, "YCOR:DOG:113:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "YCOR:DOG:113:TRIMDLYPCT")
 field(INPF, "YCOR:DOG:113:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "YCOR:DOG:113:RAMPTIME_LEFT PP")
}

record(longout, "YCOR:DOG:113:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "YCOR:DOG:113:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "YCOR:DOG:113:RAMPDONE_CALC")
}

record(calc, "YCOR:DOG:113:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "YCOR:DOG:113:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "YCOR:DOG:113:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "YCOR:DOG:113:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:DOG:113:RAMPTIME_LEFT")
 field(OUT,  "YCOR:DOG:113:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "YCOR:DOG:113:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:DOG:113:RAMPTIME_LEFT NMS")
 field(OUT,  "YCOR:DOG:113:RAMPDONE PP")
}

record(bo, "YCOR:DOG:113:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "YCOR:DOG:113:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "YCOR:DOG:113:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "YCOR:DOG:113:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:113:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "YCOR:DOG:113:DEBUG.PROC PP")
  field(LNK2, "YCOR:DOG:113:STDZCYCLENUM.PROC PP")
  field(LNK3, "YCOR:DOG:113:STDZDISABLE.PROC PP")
  field(LNK4, "YCOR:DOG:113:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "YCOR:DOG:113:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "YCOR:DOG:113:STDZIMIN NPP NMS")
  field(INPB, "YCOR:DOG:113:STDZIMAX NPP NMS")
  field(INPC, "YCOR:DOG:113:STDZIFINAL NPP NMS")
  field(INPD, "YCOR:DOG:113:STDZCYCLENUM NPP NMS")
  field(INPE, "YCOR:DOG:113:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "YCOR:DOG:113:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "YCOR:DOG:113:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "YCOR:DOG:113:STDZWF PP")
  field(OUTB, "YCOR:DOG:113:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "YCOR:DOG:113:STDZWF")
}

record(mbbo, "YCOR:DOG:113:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "YCOR:DOG:113:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "YCOR:DOG:113:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "YCOR:DOG:113:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "YCOR:DOG:113:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "YCOR:DOG:113:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "YCOR:DOG:113:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:DOG:113:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:DOG:113:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "YCOR:DOG:113:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:113:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "YCOR:DOG:113:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "YCOR:DOG:113:STDZIMIN")
}

record(ao, "YCOR:DOG:113:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(VAL,  "-6")
  field(FLNK, "YCOR:DOG:113:STDZIMAX")
}

record(ao, "YCOR:DOG:113:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(VAL,  "6")
  field(FLNK, "YCOR:DOG:113:STDZIFINAL")
}

record(ao, "YCOR:DOG:113:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(VAL,  "-6")
  field(FLNK, "YCOR:DOG:113:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "YCOR:DOG:113:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "YCOR:DOG:113:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "YCOR:DOG:113:STDZIMIN CP NMS")
  field(INPB, "YCOR:DOG:113:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "YCOR:DOG:113:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "YCOR:DOG:113:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "YCOR:DOG:113:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "YCOR:DOG:113:STDZIMIN CP NMS")
  field(INPB, "YCOR:DOG:113:STDZIMAX CP NMS")
  field(INPC, "YCOR:DOG:113:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:113:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "YCOR:DOG:113:TRIMDLYPCT CP MS")
  field(INPB, "YCOR:DOG:113:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "YCOR:DOG:113:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "YCOR:DOG:113:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:113:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "YCOR:DOG:113:IDES.HOPR")
  field(INPB, "YCOR:DOG:113:STDZMINIPCT CPP NMS")
  field(INPC, "YCOR:DOG:113:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "YCOR:DOG:113:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "YCOR:DOG:113:IDES.HOPR")
  field(INPB, "YCOR:DOG:113:IDES.LOPR")
  field(INPC, "YCOR:DOG:113:STDZDIRECT.RVAL")
  field(INPD, "YCOR:DOG:113:STDZMINIDELTA")
  field(INPE, "YCOR:DOG:113:IDES")
  field(PREC, "5")
  field(FLNK, "YCOR:DOG:113:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "YCOR:DOG:113:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "YCOR:DOG:113:IDES.HOPR")
  field(INPB, "YCOR:DOG:113:IDES.LOPR")
  field(INPC, "YCOR:DOG:113:STDZDIRECT.RVAL")
  field(INPD, "YCOR:DOG:113:STDZMINIDELTA")
  field(INPE, "YCOR:DOG:113:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "YCOR:DOG:113:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "YCOR:DOG:113:IADJUST.RVAL")
  field(INPB, "YCOR:DOG:113:STDZDIRECT.RVAL")
  field(INPC, "YCOR:DOG:113:STDZOK.RVAL")
  field(INPD, "YCOR:DOG:113:STDZDISABLE.RVAL")
  field(INPE, "YCOR:DOG:113:STATE.RVAL CPP NMS")
  field(INPF, "YCOR:DOG:113:ICTRL.RVAL")
  field(INPG, "YCOR:DOG:113:STATE.SEVR")
  field(INPH, "YCOR:DOG:113:BDELTAS.M")
  field(INPI, "YCOR:DOG:113:IACT.SEVR")
  field(OUT,  "YCOR:DOG:113:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "YCOR:DOG:113:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "YCOR:DOG:113:STDZLOSTTOD.PROC")
  field(LNK2, "YCOR:DOG:113:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "YCOR:DOG:113:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:113:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:DOG:113:IACT CP")
  field(INPB, "YCOR:DOG:113:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "YCOR:DOG:113:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "YCOR:DOG:113:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:113:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:DOG:113:STDZIACTMAX")
  field(INPB, "YCOR:DOG:113:IACT")
  field(INPC, "YCOR:DOG:113:IDELTAS.I")
  field(OUT,  "YCOR:DOG:113:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "YCOR:DOG:113:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "YCOR:DOG:113:STDZOK.RVAL CP")
  field(INPB, "YCOR:DOG:113:STDZDISABLE.RVAL CP")
  field(INPC, "YCOR:DOG:113:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "YCOR:DOG:113:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "YCOR:DOG:113:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "YCOR:DOG:113:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "YCOR:DOG:113:CALBOK")
  field(INPB, "YCOR:DOG:113:CALBDISABLE")
  field(INPC, "YCOR:DOG:113:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "YCOR:DOG:113:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "YCOR:DOG:113:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "YCOR:DOG:113:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "YCOR:DOG:113:CALBSLOPE")
  field(DOL3, "YCOR:DOG:113:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "YCOR:DOG:113:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:113:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "YCOR:DOG:113:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "YCOR:DOG:113:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "YCOR:DOG:113:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "YCOR:DOG:113:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "YCOR:DOG:113:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:113:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "YCOR:DOG:113:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:113:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "YCOR:DOG:113:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "YCOR:DOG:113:IACT")
  field(INPD, "YCOR:DOG:113:DACSLOPE")
  field(INPE, "YCOR:DOG:113:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "YCOR:DOG:113:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "YCOR:DOG:113:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "6")
  field(HOPR, "6")
  field(DRVL, "-6")
  field(LOPR, "-6")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "YCOR:DOG:113:CALBIMAX")
}

record(ao, "YCOR:DOG:113:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "6")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(DRVL, "-6")
  field(EGU,  "A")
  field(VAL,  "6")
  field(FLNK, "YCOR:DOG:113:CALBSTEPNUM")
}

record(ao, "YCOR:DOG:113:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(VAL, "0")
}

record(longout, "YCOR:DOG:113:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:DOG:113:CALBIDELTA")
}

record(calc, "YCOR:DOG:113:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "YCOR:DOG:113:CALBIMAX")
  field(INPB, "YCOR:DOG:113:CALBIMIN")
  field(INPC, "YCOR:DOG:113:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "YCOR:DOG:113:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:203:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:203:IACT.HOPR")
  field(INPC, "YCOR:DOG:113:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "YCOR:DOG:113:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:DOG:113:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:113:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:113:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:113:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "YCOR:DOG:113:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:113:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:113:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:113:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "YCOR:DOG:113:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:113:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:113:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:113:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:DOG:113:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:113:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:113:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "YCOR:DOG:113:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:113:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "YCOR:DOG:113:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "YCOR:DOG:113:CALBSTEPNUM")
  field(INPB, "YCOR:DOG:113:CALBIACTWF")
  field(INPC, "YCOR:DOG:113:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "YCOR:DOG:113:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "YCOR:DOG:113:STDZITOL")

  field(INPH, "YCOR:DOG:113:DACSLOPE")
  field(INPI, "YCOR:DOG:113:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "YCOR:DOG:113:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "YCOR:DOG:113:CALBSTEPNUM")
  field(INPB, "YCOR:DOG:113:CALBIACTWF")
  field(INPC, "YCOR:DOG:113:DACWF")
  field(INPF, "YCOR:DOG:113:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe YCOR:DOG:113CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "YCOR:DOG:113:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "YCOR:DOG:113:DEGAUSIMIN.PROC PP")
  field(OUTB, "YCOR:DOG:113:DEGAUSIMAX.PROC PP")
  field(OUTC, "YCOR:DOG:113:DEGAUSTYPE.PROC PP")
  field(OUTD, "YCOR:DOG:113:DEGAUSSTEP.PROC PP")
  field(OUTE, "YCOR:DOG:113:MADNAME.PROC PP")
  field(OUTF, "YCOR:DOG:113:PSTYPE.PROC PP")
  field(OUTG, "YCOR:DOG:113:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "YCOR:DOG:113:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:DOG:113:DEGAUSIMIN NPP NMS")
  field(INPB, "YCOR:DOG:113:DEGAUSIMAX NPP NMS")
  field(INPC, "YCOR:DOG:113:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "YCOR:DOG:113:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "YCOR:DOG:113:PSTYPE NPP NMS")
  field(INPG, "YCOR:DOG:113:DEBUG.RVAL NPP NMS")
  field(INPH, "YCOR:DOG:113:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "YCOR:DOG:113:DEGAUSWF PP")
  field(OUTB, "YCOR:DOG:113:DEGAUSMSG PP")
  field(OUTC, "YCOR:DOG:113:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "YCOR:DOG:113:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"YCOR:DOG:113:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "YCOR:DOG:113:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "YCOR:DOG:113:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "YCOR:DOG:113:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "YCOR:DOG:113:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "YCOR:DOG:113:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(DRVH, "6")
  field(DRVL, "-6")
  field(VAL,  "-6")
}
record(ao, "YCOR:DOG:113:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(DRVH, "6")
  field(DRVL, "-6")
  field(VAL,  "6")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"YCOR:DOG:113:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "YCOR:DOG:113:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"YCOR:DOG:113:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "YCOR:DOG:113:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "YCOR:DOG:113:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "YCOR:DOG:113:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "YCOR:DOG:113:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:DOG:113:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:113:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:DOG:113:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:DOG:113:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "YCOR:DOG:113:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "YCOR:DOG:113:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "YCOR:DOG:113:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "YCOR:DOG:113:DEGAUS_IMAX")
  field(INPB, "YCOR:DOG:113:ISETPT")
  field(INPC, "YCOR:DOG:113:DEGAUSTYPE.RVAL")
  field(OUT,  "YCOR:DOG:113:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "YCOR:DOG:113:DEGAUS_IMAX_UPDATE")
}
record(seq, "YCOR:DOG:113:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "YCOR:DOG:113:ISETPT")
  field(LNK1, "YCOR:DOG:113:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "YCOR:DOG:113:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "6")
  field(LOPR, "-6")
  field(DRVH, "6")
  field(DRVL, "-6")
  field(VAL,  "6")
  field(FLNK, "YCOR:DOG:113:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "YCOR:DOG:113:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "YCOR:DOG:113:DEGAUS_IMAX")
  field(FLNK, "YCOR:DOG:113:DEGAUS_IMAXPOL")
}
record(bo, "YCOR:DOG:113:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:DOG:113:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "YCOR:DOG:113:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "YCOR:DOG:113:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "YCOR:DOG:113:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "6")
  field(LOPR, "-6")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "YCOR:DOG:113:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "YCOR:DOG:113:IACT")
  field(INPB, "YCOR:DOG:113:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "YCOR:DOG:113:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "YCOR:DOG:113:IACTPOL")
}
record(bo, "YCOR:DOG:113:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"YCOR:DOG:113:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "YCOR:DOG:113:DEGAUSENABLE CP")
  field(INPB, "YCOR:DOG:113:DEGAUSOK")
  field(INPC, "YCOR:DOG:113:STATE CP")
  field(INPD, "YCOR:DOG:113:STATE.SEVR")
  field(OUT,  "YCOR:DOG:113:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "YCOR:DOG:113:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "YCOR:DOG:113:DEGAUS_STATE_CHECK")
  field(LNK1, "YCOR:DOG:113:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "YCOR:DOG:113:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "YCOR:DOG:113:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "YCOR:DOG:113:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "YCOR:DOG:113:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "YCOR:DOG:113:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:DOG:113:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "YCOR:DOG:113:STATMSG.FRSV")
  field(LNK4, "YCOR:DOG:113:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:DOG:113:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:113:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:DOG:113:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "YCOR:DOG:113:STATMSG.FRSV")
  field(LNK4, "YCOR:DOG:113:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:DOG:113:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "YCOR:DOG:113:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "YCOR:DOG:113:STATMSG.FRSV")
  field(LNK3, "YCOR:DOG:113:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "YCOR:DOG:113:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:113:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "YCOR:DOG:113:STATMSG.FRSV PP")
  field(LNK3, "YCOR:DOG:113:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "YCOR:DOG:113:FUNC") {
  field(DESC, "YCOR:DOG:113 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "YCOR:DOG:113:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:DOG:113:CTRL") {
  field(DESC, "YCOR:DOG:113 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "YCOR:DOG:113:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "YCOR:DOG:113:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "YCOR:DOG:113:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "YCOR:DOG:113:BUSY") {
  field(DESC, "YCOR:DOG:113 Ctrl Done")
  field(DOL, "YCOR:DOG:113:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:113:SELECT")
}

record(bo, "YCOR:DOG:113:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "YCOR:DOG:113:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:DOG:113:CTRLSTATE") {
  field(DESC, "YCOR:DOG:113 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("YCOR:DOG:113:CTRL",20,20,0,0,"YCOR:DOG:113:CTRL")
#! Field("YCOR:DOG:113:CTRL.OUT",16777215,1,"YCOR:DOG:113:CTRL.OUT")
#! Link("YCOR:DOG:113:CTRL.OUT","YCOR:DOG:113:SELECTEN.A")
#! Field("YCOR:DOG:113:CTRL.VAL",16777215,1,"YCOR:DOG:113:CTRL.VAL")
#! Record("YCOR:DOG:113:SELECTEN",321,381,0,0,"YCOR:DOG:113:SELECTEN")
#! Field("YCOR:DOG:113:SELECTEN.A",16777215,0,"YCOR:DOG:113:SELECTEN.A")
#! Field("YCOR:DOG:113:SELECTEN.FLNK",16777215,1,"YCOR:DOG:113:SELECTEN.FLNK")
#! Link("YCOR:DOG:113:SELECTEN.FLNK","YCOR:DOG:113:BUSY")
#! Field("YCOR:DOG:113:SELECTEN.VAL",16777215,1,"YCOR:DOG:113:SELECTEN.VAL")
#! Record("YCOR:DOG:113:BUSY",623,274,0,0,"YCOR:DOG:113:BUSY")
#! Field("YCOR:DOG:113:BUSY.DOL",16777215,0,"YCOR:DOG:113:BUSY.DOL")
#! Link("YCOR:DOG:113:BUSY.DOL","YCOR:DOG:113:SELECTEN.VAL")
#! Field("YCOR:DOG:113:BUSY.FLNK",16777215,1,"YCOR:DOG:113:BUSY.FLNK")
#! Link("YCOR:DOG:113:BUSY.FLNK","YCOR:DOG:113:SELECT")
#! Record("YCOR:DOG:113:SELECT",669,508,0,1,"YCOR:DOG:113:SELECT")
#! Record("YCOR:DOG:113:FUNC",940,120,0,0,"YCOR:DOG:113:FUNC")
#! Field("YCOR:DOG:113:FUNC.OUT",16777215,0,"YCOR:DOG:113:FUNC.OUT")
#! Link("YCOR:DOG:113:FUNC.OUT","YCOR:DOG:113:CTRL.VAL")
#! Record("YCOR:DOG:113:ABORT",193,41,0,0,"YCOR:DOG:113:ABORT")
#! Record("YCOR:DOG:113:CTRLSTATE",369,34,0,0,"YCOR:DOG:113:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"YCOR:DOG:113:SELECT is used for Multi-device selection.\nIt is enabled when associated YCOR:DOG:113:CTRL is \"0\" (DONE).\nIt is disabled when associated YCOR:DOG:113:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"YCOR:DOG:113:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "YCOR:DOG:113:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "YCOR:DOG:113:BCTRL.SEVR")
  field(OUT,  "YCOR:DOG:113:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "YCOR:DOG:113:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:DOG:113:BACT")
  field(INPB, "YCOR:DOG:113:POLYCOEF")
  field(INPC, "YCOR:DOG:113:POLYCOEF.A")
  field(INPD, "YCOR:DOG:113:POLYCOEF.B")
  field(INPE, "YCOR:DOG:113:IACT MS")
  field(INPF, "YCOR:DOG:113:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.06295908")
  field(LOPR, "-0.06295908")
  field(HIHI, "0.06295908")
  field(LOLO, "-0.06295908")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.06295908")
  field(LOW,  "-0.06295908")
  field(FLNK, "YCOR:DOG:113:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "YCOR:DOG:113:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:DOG:113:BDES")
  field(INPB, "YCOR:DOG:113:TRIMBTOL")
  field(INPC, "YCOR:DOG:113:TRIMBTOLR")
  field(INPD, "YCOR:DOG:113:CHCKBTOL")
  field(INPE, "YCOR:DOG:113:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "YCOR:DOG:113:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "YCOR:DOG:113:MPSBTOL")
  field(INPQ, "YCOR:DOG:113:MPSBTOLR")
  field(FLNK, "YCOR:DOG:113:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "YCOR:DOG:113:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "YCOR:DOG:113:BDES")
  field(INPB, "YCOR:DOG:113:BDELTAS.I")
  field(INPG, "YCOR:DOG:113:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "YCOR:DOG:113:BCON.HIGH")
  field(OUTB, "YCOR:DOG:113:BCON.LOW")
  field(OUTC, "YCOR:DOG:113:BCON.HIHI")
  field(OUTD, "YCOR:DOG:113:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:113:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "YCOR:DOG:113:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:DOG:113:BDIFF")
  field(LNK2, "YCOR:DOG:113:BADIFF")
  field(LNK3, "YCOR:DOG:113:BRATIO")
  field(LNK4, "YCOR:DOG:113:MPSLIMITS")
  field(LNK5, "YCOR:DOG:113:I2BSTATUS")
  field(LNK6, "YCOR:DOG:113:IACTFO.PROC")
}

record(calc, "YCOR:DOG:113:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:DOG:113:BDES")
  field(INPB, "YCOR:DOG:113:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "YCOR:DOG:113:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "YCOR:DOG:113:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "YCOR:DOG:113:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:DOG:113:BDIFF")
  field(INPB, "YCOR:DOG:113:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "YCOR:DOG:113:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "YCOR:DOG:113:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "YCOR:DOG:113:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:DOG:113:BMON")
  field(INPB, "YCOR:DOG:113:POLYCOEF")
  field(INPC, "YCOR:DOG:113:POLYCOEF.A")
  field(INPD, "YCOR:DOG:113:POLYCOEF.B")
  field(INPE, "YCOR:DOG:113:IMON MS")
  field(INPF, "YCOR:DOG:113:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.06295908")
  field(LOPR, "-0.06295908")
  field(HIHI, "0.06295908")
  field(LOLO, "-0.06295908")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.06295908")
  field(LOW,  "-0.06295908")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:203:BDES CP
record(ao,  "YCOR:DOG:113:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.06295908")
   field(DRVL, "-0.06295908")
   field(HOPR, "0.06295908")
   field(LOPR, "-0.06295908")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "YCOR:DOG:113:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "YCOR:DOG:113:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:113:POLYCOEF")
  field(INPC, "YCOR:DOG:113:POLYCOEF.A")
  field(INPD, "YCOR:DOG:113:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.06295908")
  field(LOPR, "-0.06295908")
  field(MDEL, "-1")
  field(INPE, "YCOR:DOG:113:BDES.DRVH")
  field(INPF, "YCOR:DOG:113:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:113:IDES")
}
record(sub, "YCOR:DOG:113:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:113:POLYCOEF")
  field(INPC, "YCOR:DOG:113:POLYCOEF.A")
  field(INPD, "YCOR:DOG:113:POLYCOEF.B")
  field(INPE, "YCOR:DOG:113:BDES.DRVH")
  field(INPF, "YCOR:DOG:113:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.06295908")
  field(LOPR, "-0.06295908")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "YCOR:DOG:113:INOM")
}

record(sub, "YCOR:DOG:113:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:113:BDES.VAL")
  field(INPB, "YCOR:DOG:113:BDES.DRVH")
  field(INPC, "YCOR:DOG:113:BDES.DRVL")
  field(INPD, "YCOR:DOG:113:BDELTAS.I")
  field(INPE, "YCOR:DOG:113:BDELTAS.J")
  field(INPG, "YCOR:DOG:113:STATE")
  field(INPH, "YCOR:DOG:113:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.06295908")
  field(LOPR, "-0.06295908")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:DOG:113:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:113:BDES.VAL")
  field(INPB, "YCOR:DOG:113:BDES.DRVH")
  field(INPC, "YCOR:DOG:113:BDES.DRVL")
  field(INPD, "YCOR:DOG:113:BDELTAS.K")
  field(INPE, "YCOR:DOG:113:BDELTAS.L")
  field(INPG, "YCOR:DOG:113:STATE")
  field(INPH, "YCOR:DOG:113:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.06295908")
  field(LOPR, "-0.06295908")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:DOG:113:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "YCOR:DOG:113:BLIMITS")
  field(LNK1, "YCOR:DOG:113:BACTLIMITS.F PP")
  field(DOL2, "YCOR:DOG:113:BACTLIMITS.I")
  field(LNK2, "YCOR:DOG:113:BACT.HIGH")
  field(DOL3, "YCOR:DOG:113:BACTLIMITS.J")
  field(LNK3, "YCOR:DOG:113:BACT.LOW")
  field(DOL4, "YCOR:DOG:113:BACTLIMITS.K")
  field(LNK4, "YCOR:DOG:113:BACT.HIHI")
  field(DOL5, "YCOR:DOG:113:BACTLIMITS.L")
  field(LNK5, "YCOR:DOG:113:BACT.LOLO")
  field(DOL6, "YCOR:DOG:113:BLIMITS")
  field(LNK6, "YCOR:DOG:113:BMONLIMITS.F PP")
  field(DOL7, "YCOR:DOG:113:BMONLIMITS.I")
  field(LNK7, "YCOR:DOG:113:BMON.HIGH")
  field(DOL8, "YCOR:DOG:113:BMONLIMITS.J")
  field(LNK8, "YCOR:DOG:113:BMON.LOW")
  field(DOL9, "YCOR:DOG:113:BMONLIMITS.K")
  field(LNK9, "YCOR:DOG:113:BMON.HIHI")
  field(DOLA, "YCOR:DOG:113:BMONLIMITS.L")
  field(LNKA, "YCOR:DOG:113:BMON.LOLO")
  field(FLNK, "YCOR:DOG:113:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "YCOR:DOG:113:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.06295908")
  field(DRVL, "-0.06295908")
  field(HOPR, "0.06295908")
  field(LOPR, "-0.06295908")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "YCOR:DOG:113:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "YCOR:DOG:113:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:113:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "YCOR:DOG:113:BCTRL.VAL")
  field(LNK2, "YCOR:DOG:113:BDES PP")

  field(DOL3, "1")
  field(LNK3, "YCOR:DOG:113:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "YCOR:DOG:113:CHECKSTDZLOST.PROC PP")

  field(DOL5, "YCOR:DOG:113:BCTRL.VAL")
  field(LNK5, "YCOR:DOG:113:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "YCOR:DOG:113:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "YCOR:DOG:113:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:113:POLYCOEF")
  field(INPC, "YCOR:DOG:113:POLYCOEF.A")
  field(INPD, "YCOR:DOG:113:POLYCOEF.B")
  field(INPE, "YCOR:DOG:113:BDES.DRVH")
  field(INPF, "YCOR:DOG:113:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.06295908")
  field(LOPR, "-0.06295908")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:113:ISETPT")
}

record(ao, "YCOR:DOG:113:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.06295908")
  field(DRVL, "-0.06295908")
  field(EGU,  "kG-m")
  field(HOPR, "0.06295908")
  field(LOPR, "-0.06295908")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "YCOR:DOG:113:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "YCDOG0")
}

record(ai, "YCOR:DOG:113:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "669.042901")
}

record(ao, "YCOR:DOG:113:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.06295908")
  field(DRVL, "-0.06295908")
  field(EGU, "kG-m")
  field(HOPR, "0.06295908")
  field(LOPR, "-0.06295908")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.06295908")
  field(FLNK, "YCOR:DOG:113:BSTEP")
}

record(ao, "YCOR:DOG:113:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.06295908")
  field(DRVL, "-0.06295908")
  field(EGU, "kG-m")
  field(HOPR, "0.06295908")
  field(LOPR, "-0.06295908")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.06295908")
  field(FLNK, "YCOR:DOG:113:BSTEP")
}

record(ao, "YCOR:DOG:113:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.06295908")
  field(DRVL, "-0.06295908")
  field(EGU,  "kG-m")
  field(HOPR, "0.06295908")
  field(LOPR, "-0.06295908")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by YCOR:DOG:113:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "YCOR:DOG:113:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.06295908")
  field(LOPR, "-0.06295908")
  field(DRVH, "0.06295908")
  field(DRVL, "-0.06295908")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "YCOR:DOG:113:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "YCOR:DOG:113:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:113:POLYCOEF")
  field(INPC, "YCOR:DOG:113:POLYCOEF.A")
  field(INPD, "YCOR:DOG:113:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.06295908")
  field(LOPR, "-0.06295908")
  field(MDEL, "-1")
  field(INPE, "YCOR:DOG:113:BCON.DRVH")
  field(INPF, "YCOR:DOG:113:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:113:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "YCOR:DOG:113:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "YCOR:DOG:113:BMAX")
  field(INPB, "YCOR:DOG:113:BMIN")
  field(INPC, "YCOR:DOG:113:BMIN.SEVR")
  field(INPD, "YCOR:DOG:113:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"YCOR:DOG:113:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "YCOR:DOG:113:ONLINE CP")
  field(OUT,  "YCOR:DOG:113:BCTRLDISABLEFOUT PP")
}

record(fanout, "YCOR:DOG:113:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "YCOR:DOG:113:BCTRLDISABLECALC")
  field(LNK1, "YCOR:DOG:113:BCTRLDISABLE")
  field(LNK2, "YCOR:DOG:113:BCTRLENABLE")
}

record(stringout, "YCOR:DOG:113:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:DOG:113:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "YCOR:DOG:113:BCTRLDISV_UPDATE")
}

record(stringout, "YCOR:DOG:113:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:DOG:113:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "YCOR:DOG:113:BCTRLDISV_UPDATE")
}

record(calcout, "YCOR:DOG:113:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "YCOR:DOG:113:ONLINE")
  field(OUT,  "YCOR:DOG:113:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"YCOR:DOG:113:BACT and MON\n  are processed via links from \n  YCOR:DOG:113:IACT (device raw value readback 1)\n  and\n  YCOR:DOG:113:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from YCOR:DOG:113:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = YCOR:DOG:113:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"YCOR:DOG:113:BDES\n  is processed when set by CA users or \n  YCOR:DOG:113:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"YCOR:DOG:113:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  YCOR:DOG:113:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (YCOR:DOG:113:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"YCOR:DOG:113:B*LIMITS and YCOR:DOG:113:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:DOG:113:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"YCOR:DOG:113:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"YCOR:DOG:113:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "YCOR:DOG:113:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:113:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "YCOR:DOG:113:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "YCOR:DOG:113:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.06295908")
  field(DRVL, "-0.06295908")
  field(PINI, "YES")
  field(VAL, "0.06295908")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:113:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.06295908")
  field(DRVL, "-0.06295908")
  field(PINI, "YES")
  field(VAL, "-0.06295908")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:113:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.06295908")
  field(DRVL, "-0.06295908")
  field(PINI, "YES")
  field(VAL, "-0.06295908")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:113:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.06295908")
  field(DRVL, "-0.06295908")
  field(PINI, "YES")
  field(VAL, "-0.06295908")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "YCOR:DOG:113:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "YCOR:DOG:113:MPSLIMITS.E PP")
}

record(aSub, "YCOR:DOG:113:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "YCOR:DOG:113:MPS.RVAL")
  field(INPB, "YCOR:DOG:113:BADIFF")
  field(INPC, "YCOR:DOG:113:BDELTAS.N")
  field(INPD, "YCOR:DOG:113:BACT")
  field(INPE, "YCOR:DOG:113:MPSBITMASK.RVAL")
  field(INPF, "YCOR:DOG:113:MPSBLLIM")
  field(INPG, "YCOR:DOG:113:MPSBMIN")
  field(INPH, "YCOR:DOG:113:MPSBMAX")
  field(INPI, "YCOR:DOG:113:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "YCOR:DOG:113:INTOL.RVAL PP")
  field(OUTB, "YCOR:DOG:113:INTOL_BMIN.RVAL PP")
  field(OUTC, "YCOR:DOG:113:INTOL_BRANGE.RVAL PP")
  field(OUTD, "YCOR:DOG:113:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "YCOR:DOG:113:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:113:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:113:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:113:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:113:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:113:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:113:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:113:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "YCOR:DOG:113:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "YCOR:DOG:113:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:DOG:113:CHCKBTOL")
  field(INPB, "YCOR:DOG:113:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "YCOR:DOG:113:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "YCOR:DOG:113:CHCKBTOL")
  field(FLNK, "YCOR:DOG:113:CHCKITOL")
}

record(calc, "YCOR:DOG:113:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "YCOR:DOG:113:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "YCOR:DOG:113:BDES.HOPR")
  field(INPB, "YCOR:DOG:113:STABILITY")
  field(INPC, "YCOR:DOG:113:BDES.LOPR")
}

record(longout, "YCOR:DOG:113:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "YCOR:DOG:113:CHCKBTOL")
}

record(calc, "YCOR:DOG:113:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:DOG:113:POLYCOEF.B")
  field(INPB, "YCOR:DOG:113:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "YCOR:DOG:113:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "YCOR:DOG:113:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "YCOR:DOG:113:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "YCOR:DOG:113:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "YCOR:DOG:113:PAUGO")  
}

record(fanout, "YCOR:DOG:113:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "YCOR:DOG:113:PAUSTOP")
  field(LNK2, "YCOR:DOG:113:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "YCOR:DOG:113:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "YCOR:DOG:113:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:203:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:203:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "YCOR:DOG:113:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "YCOR:DOG:113:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:203:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:203:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "YCOR:DOG:113:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:203:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:DOG:113:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "YCOR:DOG:113:PSTYPE.RVAL")
  field(INPC, "YCOR:DOG:113:TURNEDOFF.RVAL")
  field(INPD, "YCOR:DOG:113:CONFIG.RVAL")
  field(INPE, "YCOR:DOG:113:PSCATEGORY.RVAL")
  field(INPF, "YCOR:DOG:113:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "YCOR:DOG:113:AUTOCTRL.RVAL")
  field(INPJ, "YCOR:DOG:113:OUTOFSERVICE.RVAL")
  field(INPL, "YCOR:DOG:113:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "YCOR:DOG:113:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "YCOR:DOG:113:PAU")
  field(INPP, "YCOR:DOG:113:CALBDISABLE.RVAL")
  field(INPQ, "YCOR:DOG:113:PTRBDISABLE.RVAL")
  field(INPR, "YCOR:DOG:113:TRIMDISABLE.RVAL")
  field(INPS, "YCOR:DOG:113:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "YCOR:DOG:113:FBCK")
  field(INPU, "YCOR:DOG:113:TRIMTYPE.RVAL")
  field(INPV, "YCOR:DOG:113:STDZDIRECT.RVAL")
  field(INPW, "YCOR:DOG:113:DEGAUSENABLE.RVAL")
  field(FLNK, "YCOR:DOG:113:HSTA")
}

record(longin, "YCOR:DOG:113:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "YCOR:DOG:113:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "YCOR:DOG:113:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "YCOR:DOG:113:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "YCOR:DOG:113:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:113:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:113:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:113:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by YCOR:DOG:113:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses YCOR:DOG:113:FBCK.
# This PV should be replaced by YCOR:DOG:113:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "YCOR:DOG:113:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "YCOR:DOG:113:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:DOG:113:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:113:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"YCOR:DOG:113:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "YCOR:DOG:113:OUTOFSERVICE NPP NMS")
  field(OUT,  "YCOR:DOG:113:ONLINE PP")
}
record(bo, "YCOR:DOG:113:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "YCOR:DOG:113:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:DOG:113:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "YCOR:DOG:113:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "YCOR:DOG:113:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "YCOR:DOG:113:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "YCOR:DOG:113:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "YCOR:DOG:113:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "YCOR:DOG:113:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:113:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:113:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:113:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "YCOR:DOG:113:TRIMTYPE")
}

record(stringout, "YCOR:DOG:113:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "YCOR:DOG:113:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "YCOR:DOG:113:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "YCOR:DOG:113:STATE.RVAL")
  field(INPB, "YCOR:DOG:113:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:DOG:113:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:DOG:113:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "YCOR:DOG:113:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "YCOR:DOG:113:STATE.RVAL")
  field(INPB, "YCOR:DOG:113:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:DOG:113:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:DOG:113:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "YCOR:DOG:113:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "YCOR:DOG:113:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "YCOR:DOG:113:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "YCOR:DOG:113:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "YCOR:DOG:113:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"YCOR:DOG:113:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("YCOR:DOG:113:TURNEDOFF",3140,1907,0,1,"YCOR:DOG:113:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:DOG:113:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "YCOR:DOG:113:BACT.STAT")
  field(INPB, "YCOR:DOG:113:BDES.STAT")
  field(INPC, "YCOR:DOG:113:IRIPL.STAT")
  field(INPD, "MCOR:EXT:203:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:203:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "YCOR:DOG:113:BACT.SEVR")
  field(INPH, "YCOR:DOG:113:BDES.SEVR")
  field(INPI, "YCOR:DOG:113:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:203:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:203:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "YCOR:DOG:113:STATE.RVAL")
  field(INPN, "YCOR:DOG:113:STDZOK")
  field(INPO, "YCOR:DOG:113:CALBOK")
  field(INPP, "YCOR:DOG:113:OUTOFSERVICE.RVAL")
  field(INPQ, "YCOR:DOG:113:CONFIG.RVAL")
  field(INPR, "YCOR:DOG:113:HSTA")
  field(INPS, "YCOR:DOG:113:CTRL.RVAL")
  field(INPT, "YCOR:DOG:113:DEGAUSOK") 
  field(INPV, "YCOR:DOG:113:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:113:STAT")
}

record(longout, "YCOR:DOG:113:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "YCOR:DOG:113:STATCTRLSUB")
  field(DOL, "YCOR:DOG:113:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "YCOR:DOG:113:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "YCOR:DOG:113:STAT")
  field(INPB, "YCOR:DOG:113:HSTA")
  field(INPD, "YCOR:DOG:113:ONOFFCTRL.RVAL")
  field(FLNK, "YCOR:DOG:113:STATMSG")
}

record(mbbo, "YCOR:DOG:113:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:DOG:113:UNAVAILGO")
  field(DOL, "YCOR:DOG:113:STATCTRLSUB.W")
}

record(seq, "YCOR:DOG:113:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "YCOR:DOG:113:STATSUB.U")
  field(LNK1, "YCOR:DOG:113:UNAVAIL PP")
}

record(stringout, "YCOR:DOG:113:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"YCOR:DOG:113:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - YCOR:DOG:113:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - YCOR:DOG:113:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"YCOR:DOG:113STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - YCOR:DOG:113:STATUS\nC - YCOR:DOG:113:ON\nD - YCOR:DOG:113:STDZOK\nE - YCOR:DOG:113:CALBOK\nF - YCOR:DOG:113:BACTDRIFT (future)\nG -\nH- YCOR:DOG:113:DACSTATUS\nI -YCOR:DOG:113:ADCSTATUS\nJ - YCOR:DOG:113:BACTSTATUS\nK - YCOR:DOG:113:BDESSTATUS\nL - YCOR:DOG:113:RIPLSTATUS\n\nOutput:\nP - YCOR:DOG:113:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "YCOR:DOG:113:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "YCOR:DOG:113:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "YCOR:DOG:113:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "YCOR:DOG:113:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "XCOR:DOG:116:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:204:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:DOG:116:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "XCOR:DOG:116:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:204:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "XCOR:DOG:116:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "2")
  field(LOLO, "-2")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "XCOR:DOG:116:BDELTAS")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "XCOR:DOG:116:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "XCOR:DOG:116:ICTRL PP")
}

# This record is processed by XCOR:DOG:116:ICON")
# Note: we are not setting alarms here.
record(ao, "XCOR:DOG:116:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "XCOR:DOG:116:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:116:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "XCOR:DOG:116:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(ao, "XCOR:DOG:116:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(FLNK, "XCOR:DOG:116:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "XCOR:DOG:116:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "XCOR:DOG:116:ISETPT.OMSL")

  field(DOL2, "XCOR:DOG:116:ICTRL")
  field(LNK2, "XCOR:DOG:116:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "XCOR:DOG:116:ISETPT.OMSL")
}

record(ao, "XCOR:DOG:116:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:116:IMIN")
}

record(ao, "XCOR:DOG:116:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(VAL,  "-2")
  field(FLNK, "XCOR:DOG:116:IRANGE")
}

record(sel, "XCOR:DOG:116:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(NVL,  "XCOR:DOG:116:BACT.SEVR")
  field(INPA, "XCOR:DOG:116:IACT NPP MS")
  field(INPB, "XCOR:DOG:116:IACTPREVOK NPP MS")
  field(INPC, "XCOR:DOG:116:IACTPREVOK NPP MS")
  field(INPD, "XCOR:DOG:116:IACTPREVOK NPP MS")
}

record(sub, "XCOR:DOG:116:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:116:IDES")
  field(INPB, "XCOR:DOG:116:ISETPT.DRVH")
  field(INPC, "XCOR:DOG:116:ISETPT.DRVL")
  field(INPD, "XCOR:DOG:116:IDELTAS.I")
  field(INPE, "XCOR:DOG:116:IDELTAS.J")
  field(INPG, "XCOR:DOG:116:STATE")
  field(INPH, "XCOR:DOG:116:HSTA")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:DOG:116:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:116:IDES")
  field(INPB, "XCOR:DOG:116:ISETPT.DRVH")
  field(INPC, "XCOR:DOG:116:ISETPT.DRVL")
  field(INPD, "XCOR:DOG:116:IDELTAS.K")
  field(INPE, "XCOR:DOG:116:IDELTAS.L")
  field(INPG, "XCOR:DOG:116:STATE")
  field(INPH, "XCOR:DOG:116:HSTA")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:DOG:116:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "XCOR:DOG:116:BLIMITS")
  field(LNK1, "XCOR:DOG:116:IACTLIMITS.F PP")
  field(DOL2, "XCOR:DOG:116:IACTLIMITS.I")
  field(LNK2, "XCOR:DOG:116:IACT.HIGH")
  field(DOL3, "XCOR:DOG:116:IACTLIMITS.J")
  field(LNK3, "XCOR:DOG:116:IACT.LOW")
  field(DOL4, "XCOR:DOG:116:IACTLIMITS.K")
  field(LNK4, "XCOR:DOG:116:IACT.HIHI")
  field(DOL5, "XCOR:DOG:116:IACTLIMITS.L")
  field(LNK5, "XCOR:DOG:116:IACT.LOLO")
  field(DOL6, "XCOR:DOG:116:BLIMITS")
  field(LNK6, "XCOR:DOG:116:IMONLIMITS.F PP")
  field(DOL7, "XCOR:DOG:116:IMONLIMITS.I")
  field(LNK7, "XCOR:DOG:116:IMON.HIGH")
  field(DOL8, "XCOR:DOG:116:IMONLIMITS.J")
  field(LNK8, "XCOR:DOG:116:IMON.LOW")
  field(DOL9, "XCOR:DOG:116:IMONLIMITS.K")
  field(LNK9, "XCOR:DOG:116:IMON.HIHI")
  field(DOLA, "XCOR:DOG:116:IMONLIMITS.L")
  field(LNKA, "XCOR:DOG:116:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "XCOR:DOG:116:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "XCOR:DOG:116:TRIMBTOL")
  field(INPE, "XCOR:DOG:116:CHCKBTOL")
  field(INPF, "XCOR:DOG:116:BDELTAS.K")
  field(INPG, "XCOR:DOG:116:BDELTAS.L")
  field(INPH, "XCOR:DOG:116:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "XCOR:DOG:116:STDZITOLR")
  field(INPC, "XCOR:DOG:116:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:204:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "XCOR:DOG:116:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:204:RESET PP
#
record(bo, "XCOR:DOG:116:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:204:RESET PP")
}

record(bo, "XCOR:DOG:116:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:204:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "XCOR:DOG:116:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "XCOR:DOG:116:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:204:IRAMPRATE PP")
  field(FLNK, "XCOR:DOG:116:STDZDLY")
}


record(ao, "XCOR:DOG:116:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:204:ISETPT PP")
  field(DOL, "XCOR:DOG:116:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "XCOR:DOG:116:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:204:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:DOG:116:BMON")
}

record(ao, "XCOR:DOG:116:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:204:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "XCOR:DOG:116:IRIPLOK")
}

record(sub, "XCOR:DOG:116:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "XCOR:DOG:116:IRIPL.VAL")
  field(INPB, "XCOR:DOG:116:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:DOG:116:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:DOG:116:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "XCOR:DOG:116:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:204:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "XCOR:DOG:116:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:204:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "XCOR:DOG:116:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:DOG:116:IACTPREVOK")
  field(LNK2, "XCOR:DOG:116:IDIFF")
  field(LNK3, "XCOR:DOG:116:IADIFF")
  field(LNK4, "XCOR:DOG:116:IRATIO")
  field(LNK5, "XCOR:DOG:116:IDIRECT")
  field(LNK6, "XCOR:DOG:116:IACTPOL_CHECK")
}

record(calc, "XCOR:DOG:116:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:DOG:116:IDES")
  field(INPB, "XCOR:DOG:116:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(calc, "XCOR:DOG:116:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "XCOR:DOG:116:IDIFF")
  field(PREC, "9")
}

record(calc, "XCOR:DOG:116:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:DOG:116:IDIFF")
  field(INPB, "XCOR:DOG:116:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "XCOR:DOG:116:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "XCOR:DOG:116:IMIN")
  field(INPB,   "XCOR:DOG:116:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "XCOR:DOG:116:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "XCOR:DOG:116:IACT")
  field(INPB, "XCOR:DOG:116:IDES")
  field(INPC, "XCOR:DOG:116:ISETPT")
  field(INPD, "XCOR:DOG:116:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "XCOR:DOG:116:IADJUST PP")
}

record(bo, "XCOR:DOG:116:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "XCOR:DOG:116:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "XCOR:DOG:116:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "XCOR:DOG:116:IACT")
  field(FLNK, "XCOR:DOG:116:IACTPOL")
}
record(bo, "XCOR:DOG:116:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:DOG:116:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"XCOR:DOG:116:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:DOG:116:IDELTAS and the\n  XCOR:DOG:116:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"XCOR:DOG:116:IACT: \n  Get copy of XCOR:DOG:116:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"XCOR:DOG:116:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"XCOR:DOG:116:IDES:\n  Contains raw value calculated by \nXCOR:DOG:116:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nXCOR:DOG:116:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"XCOR:DOG:116:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  XCOR:DOG:116:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               XCOR:DOG:116:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"XCOR:DOG:116:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by XCOR:DOG:116:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, XCOR:DOG:116:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  XCOR:DOG:116:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "XCOR:DOG:116:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:116:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:DOG:116:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:DOG:116:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:DOG:116:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "XCOR:DOG:116:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "XCOR:DOG:116:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "XCOR:DOG:116:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "XCOR:DOG:116:TRIMTYPE.RVAL")
  field(INPB,   "XCOR:DOG:116:CONFIG.RVAL")
  field(OUT,    "XCOR:DOG:116:TRIMMAXNUM PP")
}
record(longout, "XCOR:DOG:116:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "XCOR:DOG:116:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "XCOR:DOG:116:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "XCOR:DOG:116:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "XCOR:DOG:116:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "XCOR:DOG:116:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "XCOR:DOG:116:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "XCOR:DOG:116:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "XCOR:DOG:116:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "XCOR:DOG:116:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "XCOR:DOG:116:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "XCOR:DOG:116:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "XCOR:DOG:116:IMOVE")
 field(INPB, "XCOR:DOG:116:IACT")
 field(INPC, "XCOR:DOG:116:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "XCOR:DOG:116:TRIMDLYPCT")
 field(INPF, "XCOR:DOG:116:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "XCOR:DOG:116:RAMPTIME_LEFT PP")
}

record(longout, "XCOR:DOG:116:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "XCOR:DOG:116:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "XCOR:DOG:116:RAMPDONE_CALC")
}

record(calc, "XCOR:DOG:116:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "XCOR:DOG:116:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "XCOR:DOG:116:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "XCOR:DOG:116:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:DOG:116:RAMPTIME_LEFT")
 field(OUT,  "XCOR:DOG:116:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "XCOR:DOG:116:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:DOG:116:RAMPTIME_LEFT NMS")
 field(OUT,  "XCOR:DOG:116:RAMPDONE PP")
}

record(bo, "XCOR:DOG:116:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "XCOR:DOG:116:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "XCOR:DOG:116:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "XCOR:DOG:116:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:116:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "XCOR:DOG:116:DEBUG.PROC PP")
  field(LNK2, "XCOR:DOG:116:STDZCYCLENUM.PROC PP")
  field(LNK3, "XCOR:DOG:116:STDZDISABLE.PROC PP")
  field(LNK4, "XCOR:DOG:116:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "XCOR:DOG:116:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "XCOR:DOG:116:STDZIMIN NPP NMS")
  field(INPB, "XCOR:DOG:116:STDZIMAX NPP NMS")
  field(INPC, "XCOR:DOG:116:STDZIFINAL NPP NMS")
  field(INPD, "XCOR:DOG:116:STDZCYCLENUM NPP NMS")
  field(INPE, "XCOR:DOG:116:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "XCOR:DOG:116:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "XCOR:DOG:116:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "XCOR:DOG:116:STDZWF PP")
  field(OUTB, "XCOR:DOG:116:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "XCOR:DOG:116:STDZWF")
}

record(mbbo, "XCOR:DOG:116:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "XCOR:DOG:116:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "XCOR:DOG:116:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "XCOR:DOG:116:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "XCOR:DOG:116:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "XCOR:DOG:116:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "XCOR:DOG:116:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:DOG:116:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:DOG:116:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "XCOR:DOG:116:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:116:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "XCOR:DOG:116:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "XCOR:DOG:116:STDZIMIN")
}

record(ao, "XCOR:DOG:116:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "XCOR:DOG:116:STDZIMAX")
}

record(ao, "XCOR:DOG:116:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:116:STDZIFINAL")
}

record(ao, "XCOR:DOG:116:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "XCOR:DOG:116:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "XCOR:DOG:116:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "XCOR:DOG:116:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "XCOR:DOG:116:STDZIMIN CP NMS")
  field(INPB, "XCOR:DOG:116:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "XCOR:DOG:116:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "XCOR:DOG:116:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "XCOR:DOG:116:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "XCOR:DOG:116:STDZIMIN CP NMS")
  field(INPB, "XCOR:DOG:116:STDZIMAX CP NMS")
  field(INPC, "XCOR:DOG:116:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:116:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "XCOR:DOG:116:TRIMDLYPCT CP MS")
  field(INPB, "XCOR:DOG:116:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "XCOR:DOG:116:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "XCOR:DOG:116:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:116:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "XCOR:DOG:116:IDES.HOPR")
  field(INPB, "XCOR:DOG:116:STDZMINIPCT CPP NMS")
  field(INPC, "XCOR:DOG:116:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "XCOR:DOG:116:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "XCOR:DOG:116:IDES.HOPR")
  field(INPB, "XCOR:DOG:116:IDES.LOPR")
  field(INPC, "XCOR:DOG:116:STDZDIRECT.RVAL")
  field(INPD, "XCOR:DOG:116:STDZMINIDELTA")
  field(INPE, "XCOR:DOG:116:IDES")
  field(PREC, "5")
  field(FLNK, "XCOR:DOG:116:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "XCOR:DOG:116:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "XCOR:DOG:116:IDES.HOPR")
  field(INPB, "XCOR:DOG:116:IDES.LOPR")
  field(INPC, "XCOR:DOG:116:STDZDIRECT.RVAL")
  field(INPD, "XCOR:DOG:116:STDZMINIDELTA")
  field(INPE, "XCOR:DOG:116:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "XCOR:DOG:116:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "XCOR:DOG:116:IADJUST.RVAL")
  field(INPB, "XCOR:DOG:116:STDZDIRECT.RVAL")
  field(INPC, "XCOR:DOG:116:STDZOK.RVAL")
  field(INPD, "XCOR:DOG:116:STDZDISABLE.RVAL")
  field(INPE, "XCOR:DOG:116:STATE.RVAL CPP NMS")
  field(INPF, "XCOR:DOG:116:ICTRL.RVAL")
  field(INPG, "XCOR:DOG:116:STATE.SEVR")
  field(INPH, "XCOR:DOG:116:BDELTAS.M")
  field(INPI, "XCOR:DOG:116:IACT.SEVR")
  field(OUT,  "XCOR:DOG:116:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "XCOR:DOG:116:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "XCOR:DOG:116:STDZLOSTTOD.PROC")
  field(LNK2, "XCOR:DOG:116:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "XCOR:DOG:116:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:116:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:DOG:116:IACT CP")
  field(INPB, "XCOR:DOG:116:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "XCOR:DOG:116:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "XCOR:DOG:116:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:116:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:DOG:116:STDZIACTMAX")
  field(INPB, "XCOR:DOG:116:IACT")
  field(INPC, "XCOR:DOG:116:IDELTAS.I")
  field(OUT,  "XCOR:DOG:116:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "XCOR:DOG:116:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "XCOR:DOG:116:STDZOK.RVAL CP")
  field(INPB, "XCOR:DOG:116:STDZDISABLE.RVAL CP")
  field(INPC, "XCOR:DOG:116:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "XCOR:DOG:116:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "XCOR:DOG:116:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "XCOR:DOG:116:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "XCOR:DOG:116:CALBOK")
  field(INPB, "XCOR:DOG:116:CALBDISABLE")
  field(INPC, "XCOR:DOG:116:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "XCOR:DOG:116:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "XCOR:DOG:116:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "XCOR:DOG:116:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "XCOR:DOG:116:CALBSLOPE")
  field(DOL3, "XCOR:DOG:116:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "XCOR:DOG:116:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:116:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "XCOR:DOG:116:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "XCOR:DOG:116:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "XCOR:DOG:116:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "XCOR:DOG:116:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "XCOR:DOG:116:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:116:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "XCOR:DOG:116:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:116:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "XCOR:DOG:116:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "XCOR:DOG:116:IACT")
  field(INPD, "XCOR:DOG:116:DACSLOPE")
  field(INPE, "XCOR:DOG:116:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "XCOR:DOG:116:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "XCOR:DOG:116:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "2")
  field(HOPR, "2")
  field(DRVL, "-2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "XCOR:DOG:116:CALBIMAX")
}

record(ao, "XCOR:DOG:116:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "2")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:116:CALBSTEPNUM")
}

record(ao, "XCOR:DOG:116:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL, "0")
}

record(longout, "XCOR:DOG:116:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:DOG:116:CALBIDELTA")
}

record(calc, "XCOR:DOG:116:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "XCOR:DOG:116:CALBIMAX")
  field(INPB, "XCOR:DOG:116:CALBIMIN")
  field(INPC, "XCOR:DOG:116:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "XCOR:DOG:116:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:204:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:204:IACT.HOPR")
  field(INPC, "XCOR:DOG:116:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "XCOR:DOG:116:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:DOG:116:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:116:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:116:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:116:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "XCOR:DOG:116:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:116:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:116:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:116:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "XCOR:DOG:116:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:116:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:116:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:116:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:DOG:116:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:116:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:116:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "XCOR:DOG:116:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:116:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "XCOR:DOG:116:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "XCOR:DOG:116:CALBSTEPNUM")
  field(INPB, "XCOR:DOG:116:CALBIACTWF")
  field(INPC, "XCOR:DOG:116:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "XCOR:DOG:116:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "XCOR:DOG:116:STDZITOL")

  field(INPH, "XCOR:DOG:116:DACSLOPE")
  field(INPI, "XCOR:DOG:116:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "XCOR:DOG:116:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "XCOR:DOG:116:CALBSTEPNUM")
  field(INPB, "XCOR:DOG:116:CALBIACTWF")
  field(INPC, "XCOR:DOG:116:DACWF")
  field(INPF, "XCOR:DOG:116:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe XCOR:DOG:116CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "XCOR:DOG:116:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "XCOR:DOG:116:DEGAUSIMIN.PROC PP")
  field(OUTB, "XCOR:DOG:116:DEGAUSIMAX.PROC PP")
  field(OUTC, "XCOR:DOG:116:DEGAUSTYPE.PROC PP")
  field(OUTD, "XCOR:DOG:116:DEGAUSSTEP.PROC PP")
  field(OUTE, "XCOR:DOG:116:MADNAME.PROC PP")
  field(OUTF, "XCOR:DOG:116:PSTYPE.PROC PP")
  field(OUTG, "XCOR:DOG:116:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "XCOR:DOG:116:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:DOG:116:DEGAUSIMIN NPP NMS")
  field(INPB, "XCOR:DOG:116:DEGAUSIMAX NPP NMS")
  field(INPC, "XCOR:DOG:116:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "XCOR:DOG:116:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "XCOR:DOG:116:PSTYPE NPP NMS")
  field(INPG, "XCOR:DOG:116:DEBUG.RVAL NPP NMS")
  field(INPH, "XCOR:DOG:116:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "XCOR:DOG:116:DEGAUSWF PP")
  field(OUTB, "XCOR:DOG:116:DEGAUSMSG PP")
  field(OUTC, "XCOR:DOG:116:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "XCOR:DOG:116:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"XCOR:DOG:116:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "XCOR:DOG:116:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "XCOR:DOG:116:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "XCOR:DOG:116:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "XCOR:DOG:116:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "XCOR:DOG:116:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "-2")
}
record(ao, "XCOR:DOG:116:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"XCOR:DOG:116:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "XCOR:DOG:116:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"XCOR:DOG:116:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "XCOR:DOG:116:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "XCOR:DOG:116:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "XCOR:DOG:116:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "XCOR:DOG:116:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:DOG:116:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:116:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:DOG:116:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:DOG:116:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "XCOR:DOG:116:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "XCOR:DOG:116:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "XCOR:DOG:116:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "XCOR:DOG:116:DEGAUS_IMAX")
  field(INPB, "XCOR:DOG:116:ISETPT")
  field(INPC, "XCOR:DOG:116:DEGAUSTYPE.RVAL")
  field(OUT,  "XCOR:DOG:116:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "XCOR:DOG:116:DEGAUS_IMAX_UPDATE")
}
record(seq, "XCOR:DOG:116:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "XCOR:DOG:116:ISETPT")
  field(LNK1, "XCOR:DOG:116:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "XCOR:DOG:116:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:116:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "XCOR:DOG:116:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "XCOR:DOG:116:DEGAUS_IMAX")
  field(FLNK, "XCOR:DOG:116:DEGAUS_IMAXPOL")
}
record(bo, "XCOR:DOG:116:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:DOG:116:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "XCOR:DOG:116:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "XCOR:DOG:116:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "XCOR:DOG:116:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "XCOR:DOG:116:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "XCOR:DOG:116:IACT")
  field(INPB, "XCOR:DOG:116:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "XCOR:DOG:116:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "XCOR:DOG:116:IACTPOL")
}
record(bo, "XCOR:DOG:116:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"XCOR:DOG:116:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "XCOR:DOG:116:DEGAUSENABLE CP")
  field(INPB, "XCOR:DOG:116:DEGAUSOK")
  field(INPC, "XCOR:DOG:116:STATE CP")
  field(INPD, "XCOR:DOG:116:STATE.SEVR")
  field(OUT,  "XCOR:DOG:116:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "XCOR:DOG:116:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "XCOR:DOG:116:DEGAUS_STATE_CHECK")
  field(LNK1, "XCOR:DOG:116:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "XCOR:DOG:116:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "XCOR:DOG:116:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "XCOR:DOG:116:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "XCOR:DOG:116:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "XCOR:DOG:116:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:DOG:116:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "XCOR:DOG:116:STATMSG.FRSV")
  field(LNK4, "XCOR:DOG:116:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:DOG:116:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:116:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:DOG:116:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "XCOR:DOG:116:STATMSG.FRSV")
  field(LNK4, "XCOR:DOG:116:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:DOG:116:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "XCOR:DOG:116:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "XCOR:DOG:116:STATMSG.FRSV")
  field(LNK3, "XCOR:DOG:116:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "XCOR:DOG:116:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:116:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "XCOR:DOG:116:STATMSG.FRSV PP")
  field(LNK3, "XCOR:DOG:116:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "XCOR:DOG:116:FUNC") {
  field(DESC, "XCOR:DOG:116 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "XCOR:DOG:116:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:DOG:116:CTRL") {
  field(DESC, "XCOR:DOG:116 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "XCOR:DOG:116:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "XCOR:DOG:116:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "XCOR:DOG:116:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "XCOR:DOG:116:BUSY") {
  field(DESC, "XCOR:DOG:116 Ctrl Done")
  field(DOL, "XCOR:DOG:116:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:116:SELECT")
}

record(bo, "XCOR:DOG:116:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "XCOR:DOG:116:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:DOG:116:CTRLSTATE") {
  field(DESC, "XCOR:DOG:116 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("XCOR:DOG:116:CTRL",20,20,0,0,"XCOR:DOG:116:CTRL")
#! Field("XCOR:DOG:116:CTRL.OUT",16777215,1,"XCOR:DOG:116:CTRL.OUT")
#! Link("XCOR:DOG:116:CTRL.OUT","XCOR:DOG:116:SELECTEN.A")
#! Field("XCOR:DOG:116:CTRL.VAL",16777215,1,"XCOR:DOG:116:CTRL.VAL")
#! Record("XCOR:DOG:116:SELECTEN",321,381,0,0,"XCOR:DOG:116:SELECTEN")
#! Field("XCOR:DOG:116:SELECTEN.A",16777215,0,"XCOR:DOG:116:SELECTEN.A")
#! Field("XCOR:DOG:116:SELECTEN.FLNK",16777215,1,"XCOR:DOG:116:SELECTEN.FLNK")
#! Link("XCOR:DOG:116:SELECTEN.FLNK","XCOR:DOG:116:BUSY")
#! Field("XCOR:DOG:116:SELECTEN.VAL",16777215,1,"XCOR:DOG:116:SELECTEN.VAL")
#! Record("XCOR:DOG:116:BUSY",623,274,0,0,"XCOR:DOG:116:BUSY")
#! Field("XCOR:DOG:116:BUSY.DOL",16777215,0,"XCOR:DOG:116:BUSY.DOL")
#! Link("XCOR:DOG:116:BUSY.DOL","XCOR:DOG:116:SELECTEN.VAL")
#! Field("XCOR:DOG:116:BUSY.FLNK",16777215,1,"XCOR:DOG:116:BUSY.FLNK")
#! Link("XCOR:DOG:116:BUSY.FLNK","XCOR:DOG:116:SELECT")
#! Record("XCOR:DOG:116:SELECT",669,508,0,1,"XCOR:DOG:116:SELECT")
#! Record("XCOR:DOG:116:FUNC",940,120,0,0,"XCOR:DOG:116:FUNC")
#! Field("XCOR:DOG:116:FUNC.OUT",16777215,0,"XCOR:DOG:116:FUNC.OUT")
#! Link("XCOR:DOG:116:FUNC.OUT","XCOR:DOG:116:CTRL.VAL")
#! Record("XCOR:DOG:116:ABORT",193,41,0,0,"XCOR:DOG:116:ABORT")
#! Record("XCOR:DOG:116:CTRLSTATE",369,34,0,0,"XCOR:DOG:116:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"XCOR:DOG:116:SELECT is used for Multi-device selection.\nIt is enabled when associated XCOR:DOG:116:CTRL is \"0\" (DONE).\nIt is disabled when associated XCOR:DOG:116:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"XCOR:DOG:116:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "XCOR:DOG:116:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "XCOR:DOG:116:BCTRL.SEVR")
  field(OUT,  "XCOR:DOG:116:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "XCOR:DOG:116:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:DOG:116:BACT")
  field(INPB, "XCOR:DOG:116:POLYCOEF")
  field(INPC, "XCOR:DOG:116:POLYCOEF.A")
  field(INPD, "XCOR:DOG:116:POLYCOEF.B")
  field(INPE, "XCOR:DOG:116:IACT MS")
  field(INPF, "XCOR:DOG:116:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
  field(FLNK, "XCOR:DOG:116:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "XCOR:DOG:116:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:DOG:116:BDES")
  field(INPB, "XCOR:DOG:116:TRIMBTOL")
  field(INPC, "XCOR:DOG:116:TRIMBTOLR")
  field(INPD, "XCOR:DOG:116:CHCKBTOL")
  field(INPE, "XCOR:DOG:116:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "XCOR:DOG:116:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "XCOR:DOG:116:MPSBTOL")
  field(INPQ, "XCOR:DOG:116:MPSBTOLR")
  field(FLNK, "XCOR:DOG:116:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "XCOR:DOG:116:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "XCOR:DOG:116:BDES")
  field(INPB, "XCOR:DOG:116:BDELTAS.I")
  field(INPG, "XCOR:DOG:116:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "XCOR:DOG:116:BCON.HIGH")
  field(OUTB, "XCOR:DOG:116:BCON.LOW")
  field(OUTC, "XCOR:DOG:116:BCON.HIHI")
  field(OUTD, "XCOR:DOG:116:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:116:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "XCOR:DOG:116:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:DOG:116:BDIFF")
  field(LNK2, "XCOR:DOG:116:BADIFF")
  field(LNK3, "XCOR:DOG:116:BRATIO")
  field(LNK4, "XCOR:DOG:116:MPSLIMITS")
  field(LNK5, "XCOR:DOG:116:I2BSTATUS")
  field(LNK6, "XCOR:DOG:116:IACTFO.PROC")
}

record(calc, "XCOR:DOG:116:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:DOG:116:BDES")
  field(INPB, "XCOR:DOG:116:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "XCOR:DOG:116:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "XCOR:DOG:116:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "XCOR:DOG:116:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:DOG:116:BDIFF")
  field(INPB, "XCOR:DOG:116:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "XCOR:DOG:116:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "XCOR:DOG:116:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "XCOR:DOG:116:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:DOG:116:BMON")
  field(INPB, "XCOR:DOG:116:POLYCOEF")
  field(INPC, "XCOR:DOG:116:POLYCOEF.A")
  field(INPD, "XCOR:DOG:116:POLYCOEF.B")
  field(INPE, "XCOR:DOG:116:IMON MS")
  field(INPF, "XCOR:DOG:116:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:204:BDES CP
record(ao,  "XCOR:DOG:116:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.02098636")
   field(DRVL, "-0.02098636")
   field(HOPR, "0.02098636")
   field(LOPR, "-0.02098636")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "XCOR:DOG:116:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "XCOR:DOG:116:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:116:POLYCOEF")
  field(INPC, "XCOR:DOG:116:POLYCOEF.A")
  field(INPD, "XCOR:DOG:116:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "XCOR:DOG:116:BDES.DRVH")
  field(INPF, "XCOR:DOG:116:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:116:IDES")
}
record(sub, "XCOR:DOG:116:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:116:POLYCOEF")
  field(INPC, "XCOR:DOG:116:POLYCOEF.A")
  field(INPD, "XCOR:DOG:116:POLYCOEF.B")
  field(INPE, "XCOR:DOG:116:BDES.DRVH")
  field(INPF, "XCOR:DOG:116:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "XCOR:DOG:116:INOM")
}

record(sub, "XCOR:DOG:116:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:116:BDES.VAL")
  field(INPB, "XCOR:DOG:116:BDES.DRVH")
  field(INPC, "XCOR:DOG:116:BDES.DRVL")
  field(INPD, "XCOR:DOG:116:BDELTAS.I")
  field(INPE, "XCOR:DOG:116:BDELTAS.J")
  field(INPG, "XCOR:DOG:116:STATE")
  field(INPH, "XCOR:DOG:116:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:DOG:116:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:116:BDES.VAL")
  field(INPB, "XCOR:DOG:116:BDES.DRVH")
  field(INPC, "XCOR:DOG:116:BDES.DRVL")
  field(INPD, "XCOR:DOG:116:BDELTAS.K")
  field(INPE, "XCOR:DOG:116:BDELTAS.L")
  field(INPG, "XCOR:DOG:116:STATE")
  field(INPH, "XCOR:DOG:116:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:DOG:116:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "XCOR:DOG:116:BLIMITS")
  field(LNK1, "XCOR:DOG:116:BACTLIMITS.F PP")
  field(DOL2, "XCOR:DOG:116:BACTLIMITS.I")
  field(LNK2, "XCOR:DOG:116:BACT.HIGH")
  field(DOL3, "XCOR:DOG:116:BACTLIMITS.J")
  field(LNK3, "XCOR:DOG:116:BACT.LOW")
  field(DOL4, "XCOR:DOG:116:BACTLIMITS.K")
  field(LNK4, "XCOR:DOG:116:BACT.HIHI")
  field(DOL5, "XCOR:DOG:116:BACTLIMITS.L")
  field(LNK5, "XCOR:DOG:116:BACT.LOLO")
  field(DOL6, "XCOR:DOG:116:BLIMITS")
  field(LNK6, "XCOR:DOG:116:BMONLIMITS.F PP")
  field(DOL7, "XCOR:DOG:116:BMONLIMITS.I")
  field(LNK7, "XCOR:DOG:116:BMON.HIGH")
  field(DOL8, "XCOR:DOG:116:BMONLIMITS.J")
  field(LNK8, "XCOR:DOG:116:BMON.LOW")
  field(DOL9, "XCOR:DOG:116:BMONLIMITS.K")
  field(LNK9, "XCOR:DOG:116:BMON.HIHI")
  field(DOLA, "XCOR:DOG:116:BMONLIMITS.L")
  field(LNKA, "XCOR:DOG:116:BMON.LOLO")
  field(FLNK, "XCOR:DOG:116:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "XCOR:DOG:116:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "XCOR:DOG:116:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "XCOR:DOG:116:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:116:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "XCOR:DOG:116:BCTRL.VAL")
  field(LNK2, "XCOR:DOG:116:BDES PP")

  field(DOL3, "1")
  field(LNK3, "XCOR:DOG:116:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "XCOR:DOG:116:CHECKSTDZLOST.PROC PP")

  field(DOL5, "XCOR:DOG:116:BCTRL.VAL")
  field(LNK5, "XCOR:DOG:116:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "XCOR:DOG:116:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "XCOR:DOG:116:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:116:POLYCOEF")
  field(INPC, "XCOR:DOG:116:POLYCOEF.A")
  field(INPD, "XCOR:DOG:116:POLYCOEF.B")
  field(INPE, "XCOR:DOG:116:BDES.DRVH")
  field(INPF, "XCOR:DOG:116:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:116:ISETPT")
}

record(ao, "XCOR:DOG:116:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "XCOR:DOG:116:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "XCDOG1")
}

record(ai, "XCOR:DOG:116:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "671.837541")
}

record(ao, "XCOR:DOG:116:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(FLNK, "XCOR:DOG:116:BSTEP")
}

record(ao, "XCOR:DOG:116:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(FLNK, "XCOR:DOG:116:BSTEP")
}

record(ao, "XCOR:DOG:116:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by XCOR:DOG:116:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "XCOR:DOG:116:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "XCOR:DOG:116:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "XCOR:DOG:116:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:116:POLYCOEF")
  field(INPC, "XCOR:DOG:116:POLYCOEF.A")
  field(INPD, "XCOR:DOG:116:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "XCOR:DOG:116:BCON.DRVH")
  field(INPF, "XCOR:DOG:116:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:116:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "XCOR:DOG:116:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "XCOR:DOG:116:BMAX")
  field(INPB, "XCOR:DOG:116:BMIN")
  field(INPC, "XCOR:DOG:116:BMIN.SEVR")
  field(INPD, "XCOR:DOG:116:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"XCOR:DOG:116:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "XCOR:DOG:116:ONLINE CP")
  field(OUT,  "XCOR:DOG:116:BCTRLDISABLEFOUT PP")
}

record(fanout, "XCOR:DOG:116:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "XCOR:DOG:116:BCTRLDISABLECALC")
  field(LNK1, "XCOR:DOG:116:BCTRLDISABLE")
  field(LNK2, "XCOR:DOG:116:BCTRLENABLE")
}

record(stringout, "XCOR:DOG:116:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:DOG:116:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "XCOR:DOG:116:BCTRLDISV_UPDATE")
}

record(stringout, "XCOR:DOG:116:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:DOG:116:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "XCOR:DOG:116:BCTRLDISV_UPDATE")
}

record(calcout, "XCOR:DOG:116:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "XCOR:DOG:116:ONLINE")
  field(OUT,  "XCOR:DOG:116:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"XCOR:DOG:116:BACT and MON\n  are processed via links from \n  XCOR:DOG:116:IACT (device raw value readback 1)\n  and\n  XCOR:DOG:116:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from XCOR:DOG:116:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = XCOR:DOG:116:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"XCOR:DOG:116:BDES\n  is processed when set by CA users or \n  XCOR:DOG:116:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"XCOR:DOG:116:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  XCOR:DOG:116:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (XCOR:DOG:116:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"XCOR:DOG:116:B*LIMITS and XCOR:DOG:116:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:DOG:116:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"XCOR:DOG:116:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"XCOR:DOG:116:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "XCOR:DOG:116:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:116:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "XCOR:DOG:116:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "XCOR:DOG:116:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:116:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:116:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:116:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "XCOR:DOG:116:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "XCOR:DOG:116:MPSLIMITS.E PP")
}

record(aSub, "XCOR:DOG:116:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "XCOR:DOG:116:MPS.RVAL")
  field(INPB, "XCOR:DOG:116:BADIFF")
  field(INPC, "XCOR:DOG:116:BDELTAS.N")
  field(INPD, "XCOR:DOG:116:BACT")
  field(INPE, "XCOR:DOG:116:MPSBITMASK.RVAL")
  field(INPF, "XCOR:DOG:116:MPSBLLIM")
  field(INPG, "XCOR:DOG:116:MPSBMIN")
  field(INPH, "XCOR:DOG:116:MPSBMAX")
  field(INPI, "XCOR:DOG:116:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "XCOR:DOG:116:INTOL.RVAL PP")
  field(OUTB, "XCOR:DOG:116:INTOL_BMIN.RVAL PP")
  field(OUTC, "XCOR:DOG:116:INTOL_BRANGE.RVAL PP")
  field(OUTD, "XCOR:DOG:116:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "XCOR:DOG:116:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:116:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:116:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:116:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:116:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:116:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:116:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:116:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "XCOR:DOG:116:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "XCOR:DOG:116:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:DOG:116:CHCKBTOL")
  field(INPB, "XCOR:DOG:116:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "XCOR:DOG:116:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "XCOR:DOG:116:CHCKBTOL")
  field(FLNK, "XCOR:DOG:116:CHCKITOL")
}

record(calc, "XCOR:DOG:116:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "XCOR:DOG:116:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "XCOR:DOG:116:BDES.HOPR")
  field(INPB, "XCOR:DOG:116:STABILITY")
  field(INPC, "XCOR:DOG:116:BDES.LOPR")
}

record(longout, "XCOR:DOG:116:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "XCOR:DOG:116:CHCKBTOL")
}

record(calc, "XCOR:DOG:116:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:DOG:116:POLYCOEF.B")
  field(INPB, "XCOR:DOG:116:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "XCOR:DOG:116:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "XCOR:DOG:116:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "XCOR:DOG:116:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "XCOR:DOG:116:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "XCOR:DOG:116:PAUGO")  
}

record(fanout, "XCOR:DOG:116:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "XCOR:DOG:116:PAUSTOP")
  field(LNK2, "XCOR:DOG:116:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "XCOR:DOG:116:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "XCOR:DOG:116:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:204:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:204:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "XCOR:DOG:116:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "XCOR:DOG:116:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:204:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:204:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "XCOR:DOG:116:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:204:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:DOG:116:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "XCOR:DOG:116:PSTYPE.RVAL")
  field(INPC, "XCOR:DOG:116:TURNEDOFF.RVAL")
  field(INPD, "XCOR:DOG:116:CONFIG.RVAL")
  field(INPE, "XCOR:DOG:116:PSCATEGORY.RVAL")
  field(INPF, "XCOR:DOG:116:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "XCOR:DOG:116:AUTOCTRL.RVAL")
  field(INPJ, "XCOR:DOG:116:OUTOFSERVICE.RVAL")
  field(INPL, "XCOR:DOG:116:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "XCOR:DOG:116:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "XCOR:DOG:116:PAU")
  field(INPP, "XCOR:DOG:116:CALBDISABLE.RVAL")
  field(INPQ, "XCOR:DOG:116:PTRBDISABLE.RVAL")
  field(INPR, "XCOR:DOG:116:TRIMDISABLE.RVAL")
  field(INPS, "XCOR:DOG:116:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "XCOR:DOG:116:FBCK")
  field(INPU, "XCOR:DOG:116:TRIMTYPE.RVAL")
  field(INPV, "XCOR:DOG:116:STDZDIRECT.RVAL")
  field(INPW, "XCOR:DOG:116:DEGAUSENABLE.RVAL")
  field(FLNK, "XCOR:DOG:116:HSTA")
}

record(longin, "XCOR:DOG:116:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "XCOR:DOG:116:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "XCOR:DOG:116:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "XCOR:DOG:116:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "XCOR:DOG:116:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:116:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:116:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:116:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by XCOR:DOG:116:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses XCOR:DOG:116:FBCK.
# This PV should be replaced by XCOR:DOG:116:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "XCOR:DOG:116:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "XCOR:DOG:116:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:DOG:116:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:116:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"XCOR:DOG:116:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "XCOR:DOG:116:OUTOFSERVICE NPP NMS")
  field(OUT,  "XCOR:DOG:116:ONLINE PP")
}
record(bo, "XCOR:DOG:116:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "XCOR:DOG:116:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:DOG:116:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "XCOR:DOG:116:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "XCOR:DOG:116:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "XCOR:DOG:116:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "XCOR:DOG:116:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "XCOR:DOG:116:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "XCOR:DOG:116:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:116:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:116:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:116:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "XCOR:DOG:116:TRIMTYPE")
}

record(stringout, "XCOR:DOG:116:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "XCOR:DOG:116:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "XCOR:DOG:116:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "XCOR:DOG:116:STATE.RVAL")
  field(INPB, "XCOR:DOG:116:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:DOG:116:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:DOG:116:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "XCOR:DOG:116:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "XCOR:DOG:116:STATE.RVAL")
  field(INPB, "XCOR:DOG:116:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:DOG:116:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:DOG:116:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "XCOR:DOG:116:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "XCOR:DOG:116:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "XCOR:DOG:116:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "XCOR:DOG:116:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "XCOR:DOG:116:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"XCOR:DOG:116:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("XCOR:DOG:116:TURNEDOFF",3140,1907,0,1,"XCOR:DOG:116:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:DOG:116:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "XCOR:DOG:116:BACT.STAT")
  field(INPB, "XCOR:DOG:116:BDES.STAT")
  field(INPC, "XCOR:DOG:116:IRIPL.STAT")
  field(INPD, "MCOR:EXT:204:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:204:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "XCOR:DOG:116:BACT.SEVR")
  field(INPH, "XCOR:DOG:116:BDES.SEVR")
  field(INPI, "XCOR:DOG:116:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:204:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:204:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "XCOR:DOG:116:STATE.RVAL")
  field(INPN, "XCOR:DOG:116:STDZOK")
  field(INPO, "XCOR:DOG:116:CALBOK")
  field(INPP, "XCOR:DOG:116:OUTOFSERVICE.RVAL")
  field(INPQ, "XCOR:DOG:116:CONFIG.RVAL")
  field(INPR, "XCOR:DOG:116:HSTA")
  field(INPS, "XCOR:DOG:116:CTRL.RVAL")
  field(INPT, "XCOR:DOG:116:DEGAUSOK") 
  field(INPV, "XCOR:DOG:116:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:116:STAT")
}

record(longout, "XCOR:DOG:116:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "XCOR:DOG:116:STATCTRLSUB")
  field(DOL, "XCOR:DOG:116:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "XCOR:DOG:116:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "XCOR:DOG:116:STAT")
  field(INPB, "XCOR:DOG:116:HSTA")
  field(INPD, "XCOR:DOG:116:ONOFFCTRL.RVAL")
  field(FLNK, "XCOR:DOG:116:STATMSG")
}

record(mbbo, "XCOR:DOG:116:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:DOG:116:UNAVAILGO")
  field(DOL, "XCOR:DOG:116:STATCTRLSUB.W")
}

record(seq, "XCOR:DOG:116:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "XCOR:DOG:116:STATSUB.U")
  field(LNK1, "XCOR:DOG:116:UNAVAIL PP")
}

record(stringout, "XCOR:DOG:116:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"XCOR:DOG:116:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - XCOR:DOG:116:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - XCOR:DOG:116:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"XCOR:DOG:116STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - XCOR:DOG:116:STATUS\nC - XCOR:DOG:116:ON\nD - XCOR:DOG:116:STDZOK\nE - XCOR:DOG:116:CALBOK\nF - XCOR:DOG:116:BACTDRIFT (future)\nG -\nH- XCOR:DOG:116:DACSTATUS\nI -XCOR:DOG:116:ADCSTATUS\nJ - XCOR:DOG:116:BACTSTATUS\nK - XCOR:DOG:116:BDESSTATUS\nL - XCOR:DOG:116:RIPLSTATUS\n\nOutput:\nP - XCOR:DOG:116:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "XCOR:DOG:116:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "XCOR:DOG:116:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "XCOR:DOG:116:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "XCOR:DOG:116:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "YCOR:DOG:137:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:205:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:DOG:137:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "YCOR:DOG:137:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:205:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "YCOR:DOG:137:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "2")
  field(LOLO, "-2")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "YCOR:DOG:137:BDELTAS")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "YCOR:DOG:137:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "YCOR:DOG:137:ICTRL PP")
}

# This record is processed by YCOR:DOG:137:ICON")
# Note: we are not setting alarms here.
record(ao, "YCOR:DOG:137:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "YCOR:DOG:137:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:137:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "YCOR:DOG:137:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(ao, "YCOR:DOG:137:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(FLNK, "YCOR:DOG:137:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "YCOR:DOG:137:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "YCOR:DOG:137:ISETPT.OMSL")

  field(DOL2, "YCOR:DOG:137:ICTRL")
  field(LNK2, "YCOR:DOG:137:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "YCOR:DOG:137:ISETPT.OMSL")
}

record(ao, "YCOR:DOG:137:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:137:IMIN")
}

record(ao, "YCOR:DOG:137:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(VAL,  "-2")
  field(FLNK, "YCOR:DOG:137:IRANGE")
}

record(sel, "YCOR:DOG:137:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(NVL,  "YCOR:DOG:137:BACT.SEVR")
  field(INPA, "YCOR:DOG:137:IACT NPP MS")
  field(INPB, "YCOR:DOG:137:IACTPREVOK NPP MS")
  field(INPC, "YCOR:DOG:137:IACTPREVOK NPP MS")
  field(INPD, "YCOR:DOG:137:IACTPREVOK NPP MS")
}

record(sub, "YCOR:DOG:137:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:137:IDES")
  field(INPB, "YCOR:DOG:137:ISETPT.DRVH")
  field(INPC, "YCOR:DOG:137:ISETPT.DRVL")
  field(INPD, "YCOR:DOG:137:IDELTAS.I")
  field(INPE, "YCOR:DOG:137:IDELTAS.J")
  field(INPG, "YCOR:DOG:137:STATE")
  field(INPH, "YCOR:DOG:137:HSTA")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:DOG:137:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:137:IDES")
  field(INPB, "YCOR:DOG:137:ISETPT.DRVH")
  field(INPC, "YCOR:DOG:137:ISETPT.DRVL")
  field(INPD, "YCOR:DOG:137:IDELTAS.K")
  field(INPE, "YCOR:DOG:137:IDELTAS.L")
  field(INPG, "YCOR:DOG:137:STATE")
  field(INPH, "YCOR:DOG:137:HSTA")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:DOG:137:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "YCOR:DOG:137:BLIMITS")
  field(LNK1, "YCOR:DOG:137:IACTLIMITS.F PP")
  field(DOL2, "YCOR:DOG:137:IACTLIMITS.I")
  field(LNK2, "YCOR:DOG:137:IACT.HIGH")
  field(DOL3, "YCOR:DOG:137:IACTLIMITS.J")
  field(LNK3, "YCOR:DOG:137:IACT.LOW")
  field(DOL4, "YCOR:DOG:137:IACTLIMITS.K")
  field(LNK4, "YCOR:DOG:137:IACT.HIHI")
  field(DOL5, "YCOR:DOG:137:IACTLIMITS.L")
  field(LNK5, "YCOR:DOG:137:IACT.LOLO")
  field(DOL6, "YCOR:DOG:137:BLIMITS")
  field(LNK6, "YCOR:DOG:137:IMONLIMITS.F PP")
  field(DOL7, "YCOR:DOG:137:IMONLIMITS.I")
  field(LNK7, "YCOR:DOG:137:IMON.HIGH")
  field(DOL8, "YCOR:DOG:137:IMONLIMITS.J")
  field(LNK8, "YCOR:DOG:137:IMON.LOW")
  field(DOL9, "YCOR:DOG:137:IMONLIMITS.K")
  field(LNK9, "YCOR:DOG:137:IMON.HIHI")
  field(DOLA, "YCOR:DOG:137:IMONLIMITS.L")
  field(LNKA, "YCOR:DOG:137:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "YCOR:DOG:137:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "YCOR:DOG:137:TRIMBTOL")
  field(INPE, "YCOR:DOG:137:CHCKBTOL")
  field(INPF, "YCOR:DOG:137:BDELTAS.K")
  field(INPG, "YCOR:DOG:137:BDELTAS.L")
  field(INPH, "YCOR:DOG:137:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "YCOR:DOG:137:STDZITOLR")
  field(INPC, "YCOR:DOG:137:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:205:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "YCOR:DOG:137:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:205:RESET PP
#
record(bo, "YCOR:DOG:137:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:205:RESET PP")
}

record(bo, "YCOR:DOG:137:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:205:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "YCOR:DOG:137:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "YCOR:DOG:137:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:205:IRAMPRATE PP")
  field(FLNK, "YCOR:DOG:137:STDZDLY")
}


record(ao, "YCOR:DOG:137:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:205:ISETPT PP")
  field(DOL, "YCOR:DOG:137:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "YCOR:DOG:137:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:205:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:DOG:137:BMON")
}

record(ao, "YCOR:DOG:137:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:205:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "YCOR:DOG:137:IRIPLOK")
}

record(sub, "YCOR:DOG:137:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "YCOR:DOG:137:IRIPL.VAL")
  field(INPB, "YCOR:DOG:137:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:DOG:137:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:DOG:137:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "YCOR:DOG:137:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:205:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "YCOR:DOG:137:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:205:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "YCOR:DOG:137:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:DOG:137:IACTPREVOK")
  field(LNK2, "YCOR:DOG:137:IDIFF")
  field(LNK3, "YCOR:DOG:137:IADIFF")
  field(LNK4, "YCOR:DOG:137:IRATIO")
  field(LNK5, "YCOR:DOG:137:IDIRECT")
  field(LNK6, "YCOR:DOG:137:IACTPOL_CHECK")
}

record(calc, "YCOR:DOG:137:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:DOG:137:IDES")
  field(INPB, "YCOR:DOG:137:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(calc, "YCOR:DOG:137:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "YCOR:DOG:137:IDIFF")
  field(PREC, "9")
}

record(calc, "YCOR:DOG:137:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:DOG:137:IDIFF")
  field(INPB, "YCOR:DOG:137:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "YCOR:DOG:137:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "YCOR:DOG:137:IMIN")
  field(INPB,   "YCOR:DOG:137:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "YCOR:DOG:137:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "YCOR:DOG:137:IACT")
  field(INPB, "YCOR:DOG:137:IDES")
  field(INPC, "YCOR:DOG:137:ISETPT")
  field(INPD, "YCOR:DOG:137:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "YCOR:DOG:137:IADJUST PP")
}

record(bo, "YCOR:DOG:137:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "YCOR:DOG:137:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "YCOR:DOG:137:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "YCOR:DOG:137:IACT")
  field(FLNK, "YCOR:DOG:137:IACTPOL")
}
record(bo, "YCOR:DOG:137:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:DOG:137:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"YCOR:DOG:137:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:DOG:137:IDELTAS and the\n  YCOR:DOG:137:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"YCOR:DOG:137:IACT: \n  Get copy of YCOR:DOG:137:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"YCOR:DOG:137:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"YCOR:DOG:137:IDES:\n  Contains raw value calculated by \nYCOR:DOG:137:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nYCOR:DOG:137:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"YCOR:DOG:137:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  YCOR:DOG:137:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               YCOR:DOG:137:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"YCOR:DOG:137:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by YCOR:DOG:137:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, YCOR:DOG:137:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  YCOR:DOG:137:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "YCOR:DOG:137:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:137:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:DOG:137:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:DOG:137:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:DOG:137:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "YCOR:DOG:137:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "YCOR:DOG:137:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "YCOR:DOG:137:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "YCOR:DOG:137:TRIMTYPE.RVAL")
  field(INPB,   "YCOR:DOG:137:CONFIG.RVAL")
  field(OUT,    "YCOR:DOG:137:TRIMMAXNUM PP")
}
record(longout, "YCOR:DOG:137:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "YCOR:DOG:137:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "YCOR:DOG:137:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "YCOR:DOG:137:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "YCOR:DOG:137:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "YCOR:DOG:137:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "YCOR:DOG:137:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "YCOR:DOG:137:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "YCOR:DOG:137:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "YCOR:DOG:137:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "YCOR:DOG:137:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "YCOR:DOG:137:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "YCOR:DOG:137:IMOVE")
 field(INPB, "YCOR:DOG:137:IACT")
 field(INPC, "YCOR:DOG:137:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "YCOR:DOG:137:TRIMDLYPCT")
 field(INPF, "YCOR:DOG:137:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "YCOR:DOG:137:RAMPTIME_LEFT PP")
}

record(longout, "YCOR:DOG:137:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "YCOR:DOG:137:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "YCOR:DOG:137:RAMPDONE_CALC")
}

record(calc, "YCOR:DOG:137:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "YCOR:DOG:137:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "YCOR:DOG:137:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "YCOR:DOG:137:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:DOG:137:RAMPTIME_LEFT")
 field(OUT,  "YCOR:DOG:137:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "YCOR:DOG:137:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:DOG:137:RAMPTIME_LEFT NMS")
 field(OUT,  "YCOR:DOG:137:RAMPDONE PP")
}

record(bo, "YCOR:DOG:137:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "YCOR:DOG:137:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "YCOR:DOG:137:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "YCOR:DOG:137:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:137:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "YCOR:DOG:137:DEBUG.PROC PP")
  field(LNK2, "YCOR:DOG:137:STDZCYCLENUM.PROC PP")
  field(LNK3, "YCOR:DOG:137:STDZDISABLE.PROC PP")
  field(LNK4, "YCOR:DOG:137:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "YCOR:DOG:137:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "YCOR:DOG:137:STDZIMIN NPP NMS")
  field(INPB, "YCOR:DOG:137:STDZIMAX NPP NMS")
  field(INPC, "YCOR:DOG:137:STDZIFINAL NPP NMS")
  field(INPD, "YCOR:DOG:137:STDZCYCLENUM NPP NMS")
  field(INPE, "YCOR:DOG:137:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "YCOR:DOG:137:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "YCOR:DOG:137:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "YCOR:DOG:137:STDZWF PP")
  field(OUTB, "YCOR:DOG:137:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "YCOR:DOG:137:STDZWF")
}

record(mbbo, "YCOR:DOG:137:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "YCOR:DOG:137:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "YCOR:DOG:137:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "YCOR:DOG:137:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "YCOR:DOG:137:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "YCOR:DOG:137:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "YCOR:DOG:137:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:DOG:137:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:DOG:137:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "YCOR:DOG:137:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:137:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "YCOR:DOG:137:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "YCOR:DOG:137:STDZIMIN")
}

record(ao, "YCOR:DOG:137:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "YCOR:DOG:137:STDZIMAX")
}

record(ao, "YCOR:DOG:137:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:137:STDZIFINAL")
}

record(ao, "YCOR:DOG:137:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "YCOR:DOG:137:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "YCOR:DOG:137:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "YCOR:DOG:137:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "YCOR:DOG:137:STDZIMIN CP NMS")
  field(INPB, "YCOR:DOG:137:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "YCOR:DOG:137:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "YCOR:DOG:137:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "YCOR:DOG:137:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "YCOR:DOG:137:STDZIMIN CP NMS")
  field(INPB, "YCOR:DOG:137:STDZIMAX CP NMS")
  field(INPC, "YCOR:DOG:137:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:137:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "YCOR:DOG:137:TRIMDLYPCT CP MS")
  field(INPB, "YCOR:DOG:137:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "YCOR:DOG:137:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "YCOR:DOG:137:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:137:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "YCOR:DOG:137:IDES.HOPR")
  field(INPB, "YCOR:DOG:137:STDZMINIPCT CPP NMS")
  field(INPC, "YCOR:DOG:137:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "YCOR:DOG:137:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "YCOR:DOG:137:IDES.HOPR")
  field(INPB, "YCOR:DOG:137:IDES.LOPR")
  field(INPC, "YCOR:DOG:137:STDZDIRECT.RVAL")
  field(INPD, "YCOR:DOG:137:STDZMINIDELTA")
  field(INPE, "YCOR:DOG:137:IDES")
  field(PREC, "5")
  field(FLNK, "YCOR:DOG:137:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "YCOR:DOG:137:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "YCOR:DOG:137:IDES.HOPR")
  field(INPB, "YCOR:DOG:137:IDES.LOPR")
  field(INPC, "YCOR:DOG:137:STDZDIRECT.RVAL")
  field(INPD, "YCOR:DOG:137:STDZMINIDELTA")
  field(INPE, "YCOR:DOG:137:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "YCOR:DOG:137:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "YCOR:DOG:137:IADJUST.RVAL")
  field(INPB, "YCOR:DOG:137:STDZDIRECT.RVAL")
  field(INPC, "YCOR:DOG:137:STDZOK.RVAL")
  field(INPD, "YCOR:DOG:137:STDZDISABLE.RVAL")
  field(INPE, "YCOR:DOG:137:STATE.RVAL CPP NMS")
  field(INPF, "YCOR:DOG:137:ICTRL.RVAL")
  field(INPG, "YCOR:DOG:137:STATE.SEVR")
  field(INPH, "YCOR:DOG:137:BDELTAS.M")
  field(INPI, "YCOR:DOG:137:IACT.SEVR")
  field(OUT,  "YCOR:DOG:137:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "YCOR:DOG:137:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "YCOR:DOG:137:STDZLOSTTOD.PROC")
  field(LNK2, "YCOR:DOG:137:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "YCOR:DOG:137:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:137:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:DOG:137:IACT CP")
  field(INPB, "YCOR:DOG:137:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "YCOR:DOG:137:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "YCOR:DOG:137:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:137:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:DOG:137:STDZIACTMAX")
  field(INPB, "YCOR:DOG:137:IACT")
  field(INPC, "YCOR:DOG:137:IDELTAS.I")
  field(OUT,  "YCOR:DOG:137:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "YCOR:DOG:137:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "YCOR:DOG:137:STDZOK.RVAL CP")
  field(INPB, "YCOR:DOG:137:STDZDISABLE.RVAL CP")
  field(INPC, "YCOR:DOG:137:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "YCOR:DOG:137:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "YCOR:DOG:137:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "YCOR:DOG:137:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "YCOR:DOG:137:CALBOK")
  field(INPB, "YCOR:DOG:137:CALBDISABLE")
  field(INPC, "YCOR:DOG:137:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "YCOR:DOG:137:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "YCOR:DOG:137:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "YCOR:DOG:137:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "YCOR:DOG:137:CALBSLOPE")
  field(DOL3, "YCOR:DOG:137:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "YCOR:DOG:137:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:137:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "YCOR:DOG:137:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "YCOR:DOG:137:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "YCOR:DOG:137:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "YCOR:DOG:137:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "YCOR:DOG:137:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:137:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "YCOR:DOG:137:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:137:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "YCOR:DOG:137:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "YCOR:DOG:137:IACT")
  field(INPD, "YCOR:DOG:137:DACSLOPE")
  field(INPE, "YCOR:DOG:137:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "YCOR:DOG:137:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "YCOR:DOG:137:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "2")
  field(HOPR, "2")
  field(DRVL, "-2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "YCOR:DOG:137:CALBIMAX")
}

record(ao, "YCOR:DOG:137:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "2")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:137:CALBSTEPNUM")
}

record(ao, "YCOR:DOG:137:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL, "0")
}

record(longout, "YCOR:DOG:137:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:DOG:137:CALBIDELTA")
}

record(calc, "YCOR:DOG:137:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "YCOR:DOG:137:CALBIMAX")
  field(INPB, "YCOR:DOG:137:CALBIMIN")
  field(INPC, "YCOR:DOG:137:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "YCOR:DOG:137:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:205:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:205:IACT.HOPR")
  field(INPC, "YCOR:DOG:137:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "YCOR:DOG:137:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:DOG:137:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:137:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:137:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:137:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "YCOR:DOG:137:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:137:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:137:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:137:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "YCOR:DOG:137:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:137:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:137:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:137:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:DOG:137:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:137:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:137:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "YCOR:DOG:137:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:137:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "YCOR:DOG:137:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "YCOR:DOG:137:CALBSTEPNUM")
  field(INPB, "YCOR:DOG:137:CALBIACTWF")
  field(INPC, "YCOR:DOG:137:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "YCOR:DOG:137:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "YCOR:DOG:137:STDZITOL")

  field(INPH, "YCOR:DOG:137:DACSLOPE")
  field(INPI, "YCOR:DOG:137:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "YCOR:DOG:137:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "YCOR:DOG:137:CALBSTEPNUM")
  field(INPB, "YCOR:DOG:137:CALBIACTWF")
  field(INPC, "YCOR:DOG:137:DACWF")
  field(INPF, "YCOR:DOG:137:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe YCOR:DOG:137CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "YCOR:DOG:137:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "YCOR:DOG:137:DEGAUSIMIN.PROC PP")
  field(OUTB, "YCOR:DOG:137:DEGAUSIMAX.PROC PP")
  field(OUTC, "YCOR:DOG:137:DEGAUSTYPE.PROC PP")
  field(OUTD, "YCOR:DOG:137:DEGAUSSTEP.PROC PP")
  field(OUTE, "YCOR:DOG:137:MADNAME.PROC PP")
  field(OUTF, "YCOR:DOG:137:PSTYPE.PROC PP")
  field(OUTG, "YCOR:DOG:137:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "YCOR:DOG:137:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:DOG:137:DEGAUSIMIN NPP NMS")
  field(INPB, "YCOR:DOG:137:DEGAUSIMAX NPP NMS")
  field(INPC, "YCOR:DOG:137:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "YCOR:DOG:137:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "YCOR:DOG:137:PSTYPE NPP NMS")
  field(INPG, "YCOR:DOG:137:DEBUG.RVAL NPP NMS")
  field(INPH, "YCOR:DOG:137:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "YCOR:DOG:137:DEGAUSWF PP")
  field(OUTB, "YCOR:DOG:137:DEGAUSMSG PP")
  field(OUTC, "YCOR:DOG:137:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "YCOR:DOG:137:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"YCOR:DOG:137:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "YCOR:DOG:137:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "YCOR:DOG:137:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "YCOR:DOG:137:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "YCOR:DOG:137:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "YCOR:DOG:137:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "-2")
}
record(ao, "YCOR:DOG:137:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"YCOR:DOG:137:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "YCOR:DOG:137:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"YCOR:DOG:137:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "YCOR:DOG:137:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "YCOR:DOG:137:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "YCOR:DOG:137:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "YCOR:DOG:137:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:DOG:137:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:137:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:DOG:137:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:DOG:137:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "YCOR:DOG:137:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "YCOR:DOG:137:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "YCOR:DOG:137:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "YCOR:DOG:137:DEGAUS_IMAX")
  field(INPB, "YCOR:DOG:137:ISETPT")
  field(INPC, "YCOR:DOG:137:DEGAUSTYPE.RVAL")
  field(OUT,  "YCOR:DOG:137:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "YCOR:DOG:137:DEGAUS_IMAX_UPDATE")
}
record(seq, "YCOR:DOG:137:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "YCOR:DOG:137:ISETPT")
  field(LNK1, "YCOR:DOG:137:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "YCOR:DOG:137:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:137:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "YCOR:DOG:137:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "YCOR:DOG:137:DEGAUS_IMAX")
  field(FLNK, "YCOR:DOG:137:DEGAUS_IMAXPOL")
}
record(bo, "YCOR:DOG:137:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:DOG:137:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "YCOR:DOG:137:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "YCOR:DOG:137:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "YCOR:DOG:137:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "YCOR:DOG:137:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "YCOR:DOG:137:IACT")
  field(INPB, "YCOR:DOG:137:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "YCOR:DOG:137:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "YCOR:DOG:137:IACTPOL")
}
record(bo, "YCOR:DOG:137:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"YCOR:DOG:137:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "YCOR:DOG:137:DEGAUSENABLE CP")
  field(INPB, "YCOR:DOG:137:DEGAUSOK")
  field(INPC, "YCOR:DOG:137:STATE CP")
  field(INPD, "YCOR:DOG:137:STATE.SEVR")
  field(OUT,  "YCOR:DOG:137:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "YCOR:DOG:137:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "YCOR:DOG:137:DEGAUS_STATE_CHECK")
  field(LNK1, "YCOR:DOG:137:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "YCOR:DOG:137:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "YCOR:DOG:137:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "YCOR:DOG:137:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "YCOR:DOG:137:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "YCOR:DOG:137:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:DOG:137:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "YCOR:DOG:137:STATMSG.FRSV")
  field(LNK4, "YCOR:DOG:137:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:DOG:137:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:137:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:DOG:137:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "YCOR:DOG:137:STATMSG.FRSV")
  field(LNK4, "YCOR:DOG:137:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:DOG:137:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "YCOR:DOG:137:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "YCOR:DOG:137:STATMSG.FRSV")
  field(LNK3, "YCOR:DOG:137:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "YCOR:DOG:137:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:137:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "YCOR:DOG:137:STATMSG.FRSV PP")
  field(LNK3, "YCOR:DOG:137:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "YCOR:DOG:137:FUNC") {
  field(DESC, "YCOR:DOG:137 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "YCOR:DOG:137:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:DOG:137:CTRL") {
  field(DESC, "YCOR:DOG:137 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "YCOR:DOG:137:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "YCOR:DOG:137:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "YCOR:DOG:137:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "YCOR:DOG:137:BUSY") {
  field(DESC, "YCOR:DOG:137 Ctrl Done")
  field(DOL, "YCOR:DOG:137:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:137:SELECT")
}

record(bo, "YCOR:DOG:137:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "YCOR:DOG:137:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:DOG:137:CTRLSTATE") {
  field(DESC, "YCOR:DOG:137 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("YCOR:DOG:137:CTRL",20,20,0,0,"YCOR:DOG:137:CTRL")
#! Field("YCOR:DOG:137:CTRL.OUT",16777215,1,"YCOR:DOG:137:CTRL.OUT")
#! Link("YCOR:DOG:137:CTRL.OUT","YCOR:DOG:137:SELECTEN.A")
#! Field("YCOR:DOG:137:CTRL.VAL",16777215,1,"YCOR:DOG:137:CTRL.VAL")
#! Record("YCOR:DOG:137:SELECTEN",321,381,0,0,"YCOR:DOG:137:SELECTEN")
#! Field("YCOR:DOG:137:SELECTEN.A",16777215,0,"YCOR:DOG:137:SELECTEN.A")
#! Field("YCOR:DOG:137:SELECTEN.FLNK",16777215,1,"YCOR:DOG:137:SELECTEN.FLNK")
#! Link("YCOR:DOG:137:SELECTEN.FLNK","YCOR:DOG:137:BUSY")
#! Field("YCOR:DOG:137:SELECTEN.VAL",16777215,1,"YCOR:DOG:137:SELECTEN.VAL")
#! Record("YCOR:DOG:137:BUSY",623,274,0,0,"YCOR:DOG:137:BUSY")
#! Field("YCOR:DOG:137:BUSY.DOL",16777215,0,"YCOR:DOG:137:BUSY.DOL")
#! Link("YCOR:DOG:137:BUSY.DOL","YCOR:DOG:137:SELECTEN.VAL")
#! Field("YCOR:DOG:137:BUSY.FLNK",16777215,1,"YCOR:DOG:137:BUSY.FLNK")
#! Link("YCOR:DOG:137:BUSY.FLNK","YCOR:DOG:137:SELECT")
#! Record("YCOR:DOG:137:SELECT",669,508,0,1,"YCOR:DOG:137:SELECT")
#! Record("YCOR:DOG:137:FUNC",940,120,0,0,"YCOR:DOG:137:FUNC")
#! Field("YCOR:DOG:137:FUNC.OUT",16777215,0,"YCOR:DOG:137:FUNC.OUT")
#! Link("YCOR:DOG:137:FUNC.OUT","YCOR:DOG:137:CTRL.VAL")
#! Record("YCOR:DOG:137:ABORT",193,41,0,0,"YCOR:DOG:137:ABORT")
#! Record("YCOR:DOG:137:CTRLSTATE",369,34,0,0,"YCOR:DOG:137:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"YCOR:DOG:137:SELECT is used for Multi-device selection.\nIt is enabled when associated YCOR:DOG:137:CTRL is \"0\" (DONE).\nIt is disabled when associated YCOR:DOG:137:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"YCOR:DOG:137:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "YCOR:DOG:137:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "YCOR:DOG:137:BCTRL.SEVR")
  field(OUT,  "YCOR:DOG:137:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "YCOR:DOG:137:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:DOG:137:BACT")
  field(INPB, "YCOR:DOG:137:POLYCOEF")
  field(INPC, "YCOR:DOG:137:POLYCOEF.A")
  field(INPD, "YCOR:DOG:137:POLYCOEF.B")
  field(INPE, "YCOR:DOG:137:IACT MS")
  field(INPF, "YCOR:DOG:137:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
  field(FLNK, "YCOR:DOG:137:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "YCOR:DOG:137:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:DOG:137:BDES")
  field(INPB, "YCOR:DOG:137:TRIMBTOL")
  field(INPC, "YCOR:DOG:137:TRIMBTOLR")
  field(INPD, "YCOR:DOG:137:CHCKBTOL")
  field(INPE, "YCOR:DOG:137:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "YCOR:DOG:137:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "YCOR:DOG:137:MPSBTOL")
  field(INPQ, "YCOR:DOG:137:MPSBTOLR")
  field(FLNK, "YCOR:DOG:137:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "YCOR:DOG:137:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "YCOR:DOG:137:BDES")
  field(INPB, "YCOR:DOG:137:BDELTAS.I")
  field(INPG, "YCOR:DOG:137:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "YCOR:DOG:137:BCON.HIGH")
  field(OUTB, "YCOR:DOG:137:BCON.LOW")
  field(OUTC, "YCOR:DOG:137:BCON.HIHI")
  field(OUTD, "YCOR:DOG:137:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:137:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "YCOR:DOG:137:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:DOG:137:BDIFF")
  field(LNK2, "YCOR:DOG:137:BADIFF")
  field(LNK3, "YCOR:DOG:137:BRATIO")
  field(LNK4, "YCOR:DOG:137:MPSLIMITS")
  field(LNK5, "YCOR:DOG:137:I2BSTATUS")
  field(LNK6, "YCOR:DOG:137:IACTFO.PROC")
}

record(calc, "YCOR:DOG:137:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:DOG:137:BDES")
  field(INPB, "YCOR:DOG:137:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "YCOR:DOG:137:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "YCOR:DOG:137:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "YCOR:DOG:137:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:DOG:137:BDIFF")
  field(INPB, "YCOR:DOG:137:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "YCOR:DOG:137:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "YCOR:DOG:137:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "YCOR:DOG:137:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:DOG:137:BMON")
  field(INPB, "YCOR:DOG:137:POLYCOEF")
  field(INPC, "YCOR:DOG:137:POLYCOEF.A")
  field(INPD, "YCOR:DOG:137:POLYCOEF.B")
  field(INPE, "YCOR:DOG:137:IMON MS")
  field(INPF, "YCOR:DOG:137:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:205:BDES CP
record(ao,  "YCOR:DOG:137:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.02098636")
   field(DRVL, "-0.02098636")
   field(HOPR, "0.02098636")
   field(LOPR, "-0.02098636")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "YCOR:DOG:137:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "YCOR:DOG:137:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:137:POLYCOEF")
  field(INPC, "YCOR:DOG:137:POLYCOEF.A")
  field(INPD, "YCOR:DOG:137:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "YCOR:DOG:137:BDES.DRVH")
  field(INPF, "YCOR:DOG:137:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:137:IDES")
}
record(sub, "YCOR:DOG:137:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:137:POLYCOEF")
  field(INPC, "YCOR:DOG:137:POLYCOEF.A")
  field(INPD, "YCOR:DOG:137:POLYCOEF.B")
  field(INPE, "YCOR:DOG:137:BDES.DRVH")
  field(INPF, "YCOR:DOG:137:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "YCOR:DOG:137:INOM")
}

record(sub, "YCOR:DOG:137:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:137:BDES.VAL")
  field(INPB, "YCOR:DOG:137:BDES.DRVH")
  field(INPC, "YCOR:DOG:137:BDES.DRVL")
  field(INPD, "YCOR:DOG:137:BDELTAS.I")
  field(INPE, "YCOR:DOG:137:BDELTAS.J")
  field(INPG, "YCOR:DOG:137:STATE")
  field(INPH, "YCOR:DOG:137:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:DOG:137:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:137:BDES.VAL")
  field(INPB, "YCOR:DOG:137:BDES.DRVH")
  field(INPC, "YCOR:DOG:137:BDES.DRVL")
  field(INPD, "YCOR:DOG:137:BDELTAS.K")
  field(INPE, "YCOR:DOG:137:BDELTAS.L")
  field(INPG, "YCOR:DOG:137:STATE")
  field(INPH, "YCOR:DOG:137:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:DOG:137:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "YCOR:DOG:137:BLIMITS")
  field(LNK1, "YCOR:DOG:137:BACTLIMITS.F PP")
  field(DOL2, "YCOR:DOG:137:BACTLIMITS.I")
  field(LNK2, "YCOR:DOG:137:BACT.HIGH")
  field(DOL3, "YCOR:DOG:137:BACTLIMITS.J")
  field(LNK3, "YCOR:DOG:137:BACT.LOW")
  field(DOL4, "YCOR:DOG:137:BACTLIMITS.K")
  field(LNK4, "YCOR:DOG:137:BACT.HIHI")
  field(DOL5, "YCOR:DOG:137:BACTLIMITS.L")
  field(LNK5, "YCOR:DOG:137:BACT.LOLO")
  field(DOL6, "YCOR:DOG:137:BLIMITS")
  field(LNK6, "YCOR:DOG:137:BMONLIMITS.F PP")
  field(DOL7, "YCOR:DOG:137:BMONLIMITS.I")
  field(LNK7, "YCOR:DOG:137:BMON.HIGH")
  field(DOL8, "YCOR:DOG:137:BMONLIMITS.J")
  field(LNK8, "YCOR:DOG:137:BMON.LOW")
  field(DOL9, "YCOR:DOG:137:BMONLIMITS.K")
  field(LNK9, "YCOR:DOG:137:BMON.HIHI")
  field(DOLA, "YCOR:DOG:137:BMONLIMITS.L")
  field(LNKA, "YCOR:DOG:137:BMON.LOLO")
  field(FLNK, "YCOR:DOG:137:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "YCOR:DOG:137:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "YCOR:DOG:137:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "YCOR:DOG:137:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:137:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "YCOR:DOG:137:BCTRL.VAL")
  field(LNK2, "YCOR:DOG:137:BDES PP")

  field(DOL3, "1")
  field(LNK3, "YCOR:DOG:137:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "YCOR:DOG:137:CHECKSTDZLOST.PROC PP")

  field(DOL5, "YCOR:DOG:137:BCTRL.VAL")
  field(LNK5, "YCOR:DOG:137:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "YCOR:DOG:137:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "YCOR:DOG:137:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:137:POLYCOEF")
  field(INPC, "YCOR:DOG:137:POLYCOEF.A")
  field(INPD, "YCOR:DOG:137:POLYCOEF.B")
  field(INPE, "YCOR:DOG:137:BDES.DRVH")
  field(INPF, "YCOR:DOG:137:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:137:ISETPT")
}

record(ao, "YCOR:DOG:137:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "YCOR:DOG:137:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "YCDOG2")
}

record(ai, "YCOR:DOG:137:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "683.195894")
}

record(ao, "YCOR:DOG:137:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(FLNK, "YCOR:DOG:137:BSTEP")
}

record(ao, "YCOR:DOG:137:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(FLNK, "YCOR:DOG:137:BSTEP")
}

record(ao, "YCOR:DOG:137:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by YCOR:DOG:137:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "YCOR:DOG:137:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "YCOR:DOG:137:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "YCOR:DOG:137:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:137:POLYCOEF")
  field(INPC, "YCOR:DOG:137:POLYCOEF.A")
  field(INPD, "YCOR:DOG:137:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "YCOR:DOG:137:BCON.DRVH")
  field(INPF, "YCOR:DOG:137:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:137:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "YCOR:DOG:137:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "YCOR:DOG:137:BMAX")
  field(INPB, "YCOR:DOG:137:BMIN")
  field(INPC, "YCOR:DOG:137:BMIN.SEVR")
  field(INPD, "YCOR:DOG:137:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"YCOR:DOG:137:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "YCOR:DOG:137:ONLINE CP")
  field(OUT,  "YCOR:DOG:137:BCTRLDISABLEFOUT PP")
}

record(fanout, "YCOR:DOG:137:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "YCOR:DOG:137:BCTRLDISABLECALC")
  field(LNK1, "YCOR:DOG:137:BCTRLDISABLE")
  field(LNK2, "YCOR:DOG:137:BCTRLENABLE")
}

record(stringout, "YCOR:DOG:137:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:DOG:137:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "YCOR:DOG:137:BCTRLDISV_UPDATE")
}

record(stringout, "YCOR:DOG:137:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:DOG:137:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "YCOR:DOG:137:BCTRLDISV_UPDATE")
}

record(calcout, "YCOR:DOG:137:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "YCOR:DOG:137:ONLINE")
  field(OUT,  "YCOR:DOG:137:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"YCOR:DOG:137:BACT and MON\n  are processed via links from \n  YCOR:DOG:137:IACT (device raw value readback 1)\n  and\n  YCOR:DOG:137:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from YCOR:DOG:137:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = YCOR:DOG:137:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"YCOR:DOG:137:BDES\n  is processed when set by CA users or \n  YCOR:DOG:137:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"YCOR:DOG:137:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  YCOR:DOG:137:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (YCOR:DOG:137:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"YCOR:DOG:137:B*LIMITS and YCOR:DOG:137:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:DOG:137:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"YCOR:DOG:137:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"YCOR:DOG:137:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "YCOR:DOG:137:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:137:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "YCOR:DOG:137:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "YCOR:DOG:137:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:137:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:137:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:137:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "YCOR:DOG:137:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "YCOR:DOG:137:MPSLIMITS.E PP")
}

record(aSub, "YCOR:DOG:137:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "YCOR:DOG:137:MPS.RVAL")
  field(INPB, "YCOR:DOG:137:BADIFF")
  field(INPC, "YCOR:DOG:137:BDELTAS.N")
  field(INPD, "YCOR:DOG:137:BACT")
  field(INPE, "YCOR:DOG:137:MPSBITMASK.RVAL")
  field(INPF, "YCOR:DOG:137:MPSBLLIM")
  field(INPG, "YCOR:DOG:137:MPSBMIN")
  field(INPH, "YCOR:DOG:137:MPSBMAX")
  field(INPI, "YCOR:DOG:137:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "YCOR:DOG:137:INTOL.RVAL PP")
  field(OUTB, "YCOR:DOG:137:INTOL_BMIN.RVAL PP")
  field(OUTC, "YCOR:DOG:137:INTOL_BRANGE.RVAL PP")
  field(OUTD, "YCOR:DOG:137:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "YCOR:DOG:137:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:137:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:137:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:137:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:137:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:137:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:137:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:137:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "YCOR:DOG:137:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "YCOR:DOG:137:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:DOG:137:CHCKBTOL")
  field(INPB, "YCOR:DOG:137:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "YCOR:DOG:137:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "YCOR:DOG:137:CHCKBTOL")
  field(FLNK, "YCOR:DOG:137:CHCKITOL")
}

record(calc, "YCOR:DOG:137:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "YCOR:DOG:137:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "YCOR:DOG:137:BDES.HOPR")
  field(INPB, "YCOR:DOG:137:STABILITY")
  field(INPC, "YCOR:DOG:137:BDES.LOPR")
}

record(longout, "YCOR:DOG:137:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "YCOR:DOG:137:CHCKBTOL")
}

record(calc, "YCOR:DOG:137:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:DOG:137:POLYCOEF.B")
  field(INPB, "YCOR:DOG:137:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "YCOR:DOG:137:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "YCOR:DOG:137:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "YCOR:DOG:137:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "YCOR:DOG:137:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "YCOR:DOG:137:PAUGO")  
}

record(fanout, "YCOR:DOG:137:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "YCOR:DOG:137:PAUSTOP")
  field(LNK2, "YCOR:DOG:137:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "YCOR:DOG:137:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "YCOR:DOG:137:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:205:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:205:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "YCOR:DOG:137:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "YCOR:DOG:137:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:205:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:205:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "YCOR:DOG:137:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:205:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:DOG:137:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "YCOR:DOG:137:PSTYPE.RVAL")
  field(INPC, "YCOR:DOG:137:TURNEDOFF.RVAL")
  field(INPD, "YCOR:DOG:137:CONFIG.RVAL")
  field(INPE, "YCOR:DOG:137:PSCATEGORY.RVAL")
  field(INPF, "YCOR:DOG:137:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "YCOR:DOG:137:AUTOCTRL.RVAL")
  field(INPJ, "YCOR:DOG:137:OUTOFSERVICE.RVAL")
  field(INPL, "YCOR:DOG:137:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "YCOR:DOG:137:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "YCOR:DOG:137:PAU")
  field(INPP, "YCOR:DOG:137:CALBDISABLE.RVAL")
  field(INPQ, "YCOR:DOG:137:PTRBDISABLE.RVAL")
  field(INPR, "YCOR:DOG:137:TRIMDISABLE.RVAL")
  field(INPS, "YCOR:DOG:137:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "YCOR:DOG:137:FBCK")
  field(INPU, "YCOR:DOG:137:TRIMTYPE.RVAL")
  field(INPV, "YCOR:DOG:137:STDZDIRECT.RVAL")
  field(INPW, "YCOR:DOG:137:DEGAUSENABLE.RVAL")
  field(FLNK, "YCOR:DOG:137:HSTA")
}

record(longin, "YCOR:DOG:137:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "YCOR:DOG:137:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "YCOR:DOG:137:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "YCOR:DOG:137:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "YCOR:DOG:137:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:137:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:137:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:137:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by YCOR:DOG:137:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses YCOR:DOG:137:FBCK.
# This PV should be replaced by YCOR:DOG:137:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "YCOR:DOG:137:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "YCOR:DOG:137:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:DOG:137:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:137:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"YCOR:DOG:137:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "YCOR:DOG:137:OUTOFSERVICE NPP NMS")
  field(OUT,  "YCOR:DOG:137:ONLINE PP")
}
record(bo, "YCOR:DOG:137:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "YCOR:DOG:137:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:DOG:137:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "YCOR:DOG:137:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "YCOR:DOG:137:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "YCOR:DOG:137:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "YCOR:DOG:137:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "YCOR:DOG:137:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "YCOR:DOG:137:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:137:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:137:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:137:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "YCOR:DOG:137:TRIMTYPE")
}

record(stringout, "YCOR:DOG:137:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "YCOR:DOG:137:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "YCOR:DOG:137:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "YCOR:DOG:137:STATE.RVAL")
  field(INPB, "YCOR:DOG:137:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:DOG:137:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:DOG:137:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "YCOR:DOG:137:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "YCOR:DOG:137:STATE.RVAL")
  field(INPB, "YCOR:DOG:137:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:DOG:137:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:DOG:137:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "YCOR:DOG:137:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "YCOR:DOG:137:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "YCOR:DOG:137:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "YCOR:DOG:137:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "YCOR:DOG:137:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"YCOR:DOG:137:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("YCOR:DOG:137:TURNEDOFF",3140,1907,0,1,"YCOR:DOG:137:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:DOG:137:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "YCOR:DOG:137:BACT.STAT")
  field(INPB, "YCOR:DOG:137:BDES.STAT")
  field(INPC, "YCOR:DOG:137:IRIPL.STAT")
  field(INPD, "MCOR:EXT:205:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:205:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "YCOR:DOG:137:BACT.SEVR")
  field(INPH, "YCOR:DOG:137:BDES.SEVR")
  field(INPI, "YCOR:DOG:137:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:205:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:205:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "YCOR:DOG:137:STATE.RVAL")
  field(INPN, "YCOR:DOG:137:STDZOK")
  field(INPO, "YCOR:DOG:137:CALBOK")
  field(INPP, "YCOR:DOG:137:OUTOFSERVICE.RVAL")
  field(INPQ, "YCOR:DOG:137:CONFIG.RVAL")
  field(INPR, "YCOR:DOG:137:HSTA")
  field(INPS, "YCOR:DOG:137:CTRL.RVAL")
  field(INPT, "YCOR:DOG:137:DEGAUSOK") 
  field(INPV, "YCOR:DOG:137:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:137:STAT")
}

record(longout, "YCOR:DOG:137:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "YCOR:DOG:137:STATCTRLSUB")
  field(DOL, "YCOR:DOG:137:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "YCOR:DOG:137:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "YCOR:DOG:137:STAT")
  field(INPB, "YCOR:DOG:137:HSTA")
  field(INPD, "YCOR:DOG:137:ONOFFCTRL.RVAL")
  field(FLNK, "YCOR:DOG:137:STATMSG")
}

record(mbbo, "YCOR:DOG:137:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:DOG:137:UNAVAILGO")
  field(DOL, "YCOR:DOG:137:STATCTRLSUB.W")
}

record(seq, "YCOR:DOG:137:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "YCOR:DOG:137:STATSUB.U")
  field(LNK1, "YCOR:DOG:137:UNAVAIL PP")
}

record(stringout, "YCOR:DOG:137:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"YCOR:DOG:137:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - YCOR:DOG:137:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - YCOR:DOG:137:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"YCOR:DOG:137STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - YCOR:DOG:137:STATUS\nC - YCOR:DOG:137:ON\nD - YCOR:DOG:137:STDZOK\nE - YCOR:DOG:137:CALBOK\nF - YCOR:DOG:137:BACTDRIFT (future)\nG -\nH- YCOR:DOG:137:DACSTATUS\nI -YCOR:DOG:137:ADCSTATUS\nJ - YCOR:DOG:137:BACTSTATUS\nK - YCOR:DOG:137:BDESSTATUS\nL - YCOR:DOG:137:RIPLSTATUS\n\nOutput:\nP - YCOR:DOG:137:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "YCOR:DOG:137:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "YCOR:DOG:137:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "YCOR:DOG:137:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "YCOR:DOG:137:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "XCOR:DOG:148:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:206:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:DOG:148:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "XCOR:DOG:148:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:206:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "XCOR:DOG:148:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "2")
  field(LOLO, "-2")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "XCOR:DOG:148:BDELTAS")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "XCOR:DOG:148:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "XCOR:DOG:148:ICTRL PP")
}

# This record is processed by XCOR:DOG:148:ICON")
# Note: we are not setting alarms here.
record(ao, "XCOR:DOG:148:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "XCOR:DOG:148:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:148:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "XCOR:DOG:148:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(ao, "XCOR:DOG:148:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(FLNK, "XCOR:DOG:148:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "XCOR:DOG:148:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "XCOR:DOG:148:ISETPT.OMSL")

  field(DOL2, "XCOR:DOG:148:ICTRL")
  field(LNK2, "XCOR:DOG:148:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "XCOR:DOG:148:ISETPT.OMSL")
}

record(ao, "XCOR:DOG:148:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:148:IMIN")
}

record(ao, "XCOR:DOG:148:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(VAL,  "-2")
  field(FLNK, "XCOR:DOG:148:IRANGE")
}

record(sel, "XCOR:DOG:148:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(NVL,  "XCOR:DOG:148:BACT.SEVR")
  field(INPA, "XCOR:DOG:148:IACT NPP MS")
  field(INPB, "XCOR:DOG:148:IACTPREVOK NPP MS")
  field(INPC, "XCOR:DOG:148:IACTPREVOK NPP MS")
  field(INPD, "XCOR:DOG:148:IACTPREVOK NPP MS")
}

record(sub, "XCOR:DOG:148:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:148:IDES")
  field(INPB, "XCOR:DOG:148:ISETPT.DRVH")
  field(INPC, "XCOR:DOG:148:ISETPT.DRVL")
  field(INPD, "XCOR:DOG:148:IDELTAS.I")
  field(INPE, "XCOR:DOG:148:IDELTAS.J")
  field(INPG, "XCOR:DOG:148:STATE")
  field(INPH, "XCOR:DOG:148:HSTA")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:DOG:148:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:148:IDES")
  field(INPB, "XCOR:DOG:148:ISETPT.DRVH")
  field(INPC, "XCOR:DOG:148:ISETPT.DRVL")
  field(INPD, "XCOR:DOG:148:IDELTAS.K")
  field(INPE, "XCOR:DOG:148:IDELTAS.L")
  field(INPG, "XCOR:DOG:148:STATE")
  field(INPH, "XCOR:DOG:148:HSTA")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:DOG:148:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "XCOR:DOG:148:BLIMITS")
  field(LNK1, "XCOR:DOG:148:IACTLIMITS.F PP")
  field(DOL2, "XCOR:DOG:148:IACTLIMITS.I")
  field(LNK2, "XCOR:DOG:148:IACT.HIGH")
  field(DOL3, "XCOR:DOG:148:IACTLIMITS.J")
  field(LNK3, "XCOR:DOG:148:IACT.LOW")
  field(DOL4, "XCOR:DOG:148:IACTLIMITS.K")
  field(LNK4, "XCOR:DOG:148:IACT.HIHI")
  field(DOL5, "XCOR:DOG:148:IACTLIMITS.L")
  field(LNK5, "XCOR:DOG:148:IACT.LOLO")
  field(DOL6, "XCOR:DOG:148:BLIMITS")
  field(LNK6, "XCOR:DOG:148:IMONLIMITS.F PP")
  field(DOL7, "XCOR:DOG:148:IMONLIMITS.I")
  field(LNK7, "XCOR:DOG:148:IMON.HIGH")
  field(DOL8, "XCOR:DOG:148:IMONLIMITS.J")
  field(LNK8, "XCOR:DOG:148:IMON.LOW")
  field(DOL9, "XCOR:DOG:148:IMONLIMITS.K")
  field(LNK9, "XCOR:DOG:148:IMON.HIHI")
  field(DOLA, "XCOR:DOG:148:IMONLIMITS.L")
  field(LNKA, "XCOR:DOG:148:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "XCOR:DOG:148:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "XCOR:DOG:148:TRIMBTOL")
  field(INPE, "XCOR:DOG:148:CHCKBTOL")
  field(INPF, "XCOR:DOG:148:BDELTAS.K")
  field(INPG, "XCOR:DOG:148:BDELTAS.L")
  field(INPH, "XCOR:DOG:148:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "XCOR:DOG:148:STDZITOLR")
  field(INPC, "XCOR:DOG:148:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:206:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "XCOR:DOG:148:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:206:RESET PP
#
record(bo, "XCOR:DOG:148:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:206:RESET PP")
}

record(bo, "XCOR:DOG:148:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:206:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "XCOR:DOG:148:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "XCOR:DOG:148:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:206:IRAMPRATE PP")
  field(FLNK, "XCOR:DOG:148:STDZDLY")
}


record(ao, "XCOR:DOG:148:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:206:ISETPT PP")
  field(DOL, "XCOR:DOG:148:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "XCOR:DOG:148:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:206:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:DOG:148:BMON")
}

record(ao, "XCOR:DOG:148:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:206:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "XCOR:DOG:148:IRIPLOK")
}

record(sub, "XCOR:DOG:148:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "XCOR:DOG:148:IRIPL.VAL")
  field(INPB, "XCOR:DOG:148:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:DOG:148:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:DOG:148:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "XCOR:DOG:148:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:206:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "XCOR:DOG:148:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:206:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "XCOR:DOG:148:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:DOG:148:IACTPREVOK")
  field(LNK2, "XCOR:DOG:148:IDIFF")
  field(LNK3, "XCOR:DOG:148:IADIFF")
  field(LNK4, "XCOR:DOG:148:IRATIO")
  field(LNK5, "XCOR:DOG:148:IDIRECT")
  field(LNK6, "XCOR:DOG:148:IACTPOL_CHECK")
}

record(calc, "XCOR:DOG:148:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:DOG:148:IDES")
  field(INPB, "XCOR:DOG:148:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(calc, "XCOR:DOG:148:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "XCOR:DOG:148:IDIFF")
  field(PREC, "9")
}

record(calc, "XCOR:DOG:148:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:DOG:148:IDIFF")
  field(INPB, "XCOR:DOG:148:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "XCOR:DOG:148:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "XCOR:DOG:148:IMIN")
  field(INPB,   "XCOR:DOG:148:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "XCOR:DOG:148:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "XCOR:DOG:148:IACT")
  field(INPB, "XCOR:DOG:148:IDES")
  field(INPC, "XCOR:DOG:148:ISETPT")
  field(INPD, "XCOR:DOG:148:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "XCOR:DOG:148:IADJUST PP")
}

record(bo, "XCOR:DOG:148:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "XCOR:DOG:148:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "XCOR:DOG:148:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "XCOR:DOG:148:IACT")
  field(FLNK, "XCOR:DOG:148:IACTPOL")
}
record(bo, "XCOR:DOG:148:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:DOG:148:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"XCOR:DOG:148:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:DOG:148:IDELTAS and the\n  XCOR:DOG:148:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"XCOR:DOG:148:IACT: \n  Get copy of XCOR:DOG:148:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"XCOR:DOG:148:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"XCOR:DOG:148:IDES:\n  Contains raw value calculated by \nXCOR:DOG:148:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nXCOR:DOG:148:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"XCOR:DOG:148:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  XCOR:DOG:148:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               XCOR:DOG:148:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"XCOR:DOG:148:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by XCOR:DOG:148:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, XCOR:DOG:148:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  XCOR:DOG:148:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "XCOR:DOG:148:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:148:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:DOG:148:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:DOG:148:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:DOG:148:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "XCOR:DOG:148:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "XCOR:DOG:148:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "XCOR:DOG:148:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "XCOR:DOG:148:TRIMTYPE.RVAL")
  field(INPB,   "XCOR:DOG:148:CONFIG.RVAL")
  field(OUT,    "XCOR:DOG:148:TRIMMAXNUM PP")
}
record(longout, "XCOR:DOG:148:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "XCOR:DOG:148:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "XCOR:DOG:148:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "XCOR:DOG:148:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "XCOR:DOG:148:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "XCOR:DOG:148:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "XCOR:DOG:148:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "XCOR:DOG:148:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "XCOR:DOG:148:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "XCOR:DOG:148:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "XCOR:DOG:148:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "XCOR:DOG:148:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "XCOR:DOG:148:IMOVE")
 field(INPB, "XCOR:DOG:148:IACT")
 field(INPC, "XCOR:DOG:148:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "XCOR:DOG:148:TRIMDLYPCT")
 field(INPF, "XCOR:DOG:148:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "XCOR:DOG:148:RAMPTIME_LEFT PP")
}

record(longout, "XCOR:DOG:148:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "XCOR:DOG:148:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "XCOR:DOG:148:RAMPDONE_CALC")
}

record(calc, "XCOR:DOG:148:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "XCOR:DOG:148:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "XCOR:DOG:148:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "XCOR:DOG:148:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:DOG:148:RAMPTIME_LEFT")
 field(OUT,  "XCOR:DOG:148:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "XCOR:DOG:148:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:DOG:148:RAMPTIME_LEFT NMS")
 field(OUT,  "XCOR:DOG:148:RAMPDONE PP")
}

record(bo, "XCOR:DOG:148:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "XCOR:DOG:148:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "XCOR:DOG:148:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "XCOR:DOG:148:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:148:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "XCOR:DOG:148:DEBUG.PROC PP")
  field(LNK2, "XCOR:DOG:148:STDZCYCLENUM.PROC PP")
  field(LNK3, "XCOR:DOG:148:STDZDISABLE.PROC PP")
  field(LNK4, "XCOR:DOG:148:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "XCOR:DOG:148:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "XCOR:DOG:148:STDZIMIN NPP NMS")
  field(INPB, "XCOR:DOG:148:STDZIMAX NPP NMS")
  field(INPC, "XCOR:DOG:148:STDZIFINAL NPP NMS")
  field(INPD, "XCOR:DOG:148:STDZCYCLENUM NPP NMS")
  field(INPE, "XCOR:DOG:148:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "XCOR:DOG:148:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "XCOR:DOG:148:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "XCOR:DOG:148:STDZWF PP")
  field(OUTB, "XCOR:DOG:148:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "XCOR:DOG:148:STDZWF")
}

record(mbbo, "XCOR:DOG:148:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "XCOR:DOG:148:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "XCOR:DOG:148:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "XCOR:DOG:148:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "XCOR:DOG:148:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "XCOR:DOG:148:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "XCOR:DOG:148:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:DOG:148:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:DOG:148:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "XCOR:DOG:148:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:148:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "XCOR:DOG:148:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "XCOR:DOG:148:STDZIMIN")
}

record(ao, "XCOR:DOG:148:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "XCOR:DOG:148:STDZIMAX")
}

record(ao, "XCOR:DOG:148:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:148:STDZIFINAL")
}

record(ao, "XCOR:DOG:148:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "XCOR:DOG:148:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "XCOR:DOG:148:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "XCOR:DOG:148:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "XCOR:DOG:148:STDZIMIN CP NMS")
  field(INPB, "XCOR:DOG:148:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "XCOR:DOG:148:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "XCOR:DOG:148:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "XCOR:DOG:148:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "XCOR:DOG:148:STDZIMIN CP NMS")
  field(INPB, "XCOR:DOG:148:STDZIMAX CP NMS")
  field(INPC, "XCOR:DOG:148:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:148:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "XCOR:DOG:148:TRIMDLYPCT CP MS")
  field(INPB, "XCOR:DOG:148:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "XCOR:DOG:148:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "XCOR:DOG:148:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:148:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "XCOR:DOG:148:IDES.HOPR")
  field(INPB, "XCOR:DOG:148:STDZMINIPCT CPP NMS")
  field(INPC, "XCOR:DOG:148:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "XCOR:DOG:148:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "XCOR:DOG:148:IDES.HOPR")
  field(INPB, "XCOR:DOG:148:IDES.LOPR")
  field(INPC, "XCOR:DOG:148:STDZDIRECT.RVAL")
  field(INPD, "XCOR:DOG:148:STDZMINIDELTA")
  field(INPE, "XCOR:DOG:148:IDES")
  field(PREC, "5")
  field(FLNK, "XCOR:DOG:148:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "XCOR:DOG:148:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "XCOR:DOG:148:IDES.HOPR")
  field(INPB, "XCOR:DOG:148:IDES.LOPR")
  field(INPC, "XCOR:DOG:148:STDZDIRECT.RVAL")
  field(INPD, "XCOR:DOG:148:STDZMINIDELTA")
  field(INPE, "XCOR:DOG:148:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "XCOR:DOG:148:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "XCOR:DOG:148:IADJUST.RVAL")
  field(INPB, "XCOR:DOG:148:STDZDIRECT.RVAL")
  field(INPC, "XCOR:DOG:148:STDZOK.RVAL")
  field(INPD, "XCOR:DOG:148:STDZDISABLE.RVAL")
  field(INPE, "XCOR:DOG:148:STATE.RVAL CPP NMS")
  field(INPF, "XCOR:DOG:148:ICTRL.RVAL")
  field(INPG, "XCOR:DOG:148:STATE.SEVR")
  field(INPH, "XCOR:DOG:148:BDELTAS.M")
  field(INPI, "XCOR:DOG:148:IACT.SEVR")
  field(OUT,  "XCOR:DOG:148:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "XCOR:DOG:148:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "XCOR:DOG:148:STDZLOSTTOD.PROC")
  field(LNK2, "XCOR:DOG:148:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "XCOR:DOG:148:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:148:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:DOG:148:IACT CP")
  field(INPB, "XCOR:DOG:148:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "XCOR:DOG:148:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "XCOR:DOG:148:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:148:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:DOG:148:STDZIACTMAX")
  field(INPB, "XCOR:DOG:148:IACT")
  field(INPC, "XCOR:DOG:148:IDELTAS.I")
  field(OUT,  "XCOR:DOG:148:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "XCOR:DOG:148:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "XCOR:DOG:148:STDZOK.RVAL CP")
  field(INPB, "XCOR:DOG:148:STDZDISABLE.RVAL CP")
  field(INPC, "XCOR:DOG:148:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "XCOR:DOG:148:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "XCOR:DOG:148:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "XCOR:DOG:148:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "XCOR:DOG:148:CALBOK")
  field(INPB, "XCOR:DOG:148:CALBDISABLE")
  field(INPC, "XCOR:DOG:148:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "XCOR:DOG:148:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "XCOR:DOG:148:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "XCOR:DOG:148:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "XCOR:DOG:148:CALBSLOPE")
  field(DOL3, "XCOR:DOG:148:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "XCOR:DOG:148:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:148:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "XCOR:DOG:148:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "XCOR:DOG:148:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "XCOR:DOG:148:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "XCOR:DOG:148:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "XCOR:DOG:148:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:148:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "XCOR:DOG:148:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:148:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "XCOR:DOG:148:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "XCOR:DOG:148:IACT")
  field(INPD, "XCOR:DOG:148:DACSLOPE")
  field(INPE, "XCOR:DOG:148:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "XCOR:DOG:148:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "XCOR:DOG:148:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "2")
  field(HOPR, "2")
  field(DRVL, "-2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "XCOR:DOG:148:CALBIMAX")
}

record(ao, "XCOR:DOG:148:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "2")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:148:CALBSTEPNUM")
}

record(ao, "XCOR:DOG:148:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL, "0")
}

record(longout, "XCOR:DOG:148:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:DOG:148:CALBIDELTA")
}

record(calc, "XCOR:DOG:148:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "XCOR:DOG:148:CALBIMAX")
  field(INPB, "XCOR:DOG:148:CALBIMIN")
  field(INPC, "XCOR:DOG:148:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "XCOR:DOG:148:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:206:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:206:IACT.HOPR")
  field(INPC, "XCOR:DOG:148:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "XCOR:DOG:148:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:DOG:148:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:148:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:148:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:148:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "XCOR:DOG:148:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:148:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:148:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:148:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "XCOR:DOG:148:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:148:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:148:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:148:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:DOG:148:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:148:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:148:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "XCOR:DOG:148:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:148:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "XCOR:DOG:148:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "XCOR:DOG:148:CALBSTEPNUM")
  field(INPB, "XCOR:DOG:148:CALBIACTWF")
  field(INPC, "XCOR:DOG:148:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "XCOR:DOG:148:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "XCOR:DOG:148:STDZITOL")

  field(INPH, "XCOR:DOG:148:DACSLOPE")
  field(INPI, "XCOR:DOG:148:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "XCOR:DOG:148:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "XCOR:DOG:148:CALBSTEPNUM")
  field(INPB, "XCOR:DOG:148:CALBIACTWF")
  field(INPC, "XCOR:DOG:148:DACWF")
  field(INPF, "XCOR:DOG:148:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe XCOR:DOG:148CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "XCOR:DOG:148:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "XCOR:DOG:148:DEGAUSIMIN.PROC PP")
  field(OUTB, "XCOR:DOG:148:DEGAUSIMAX.PROC PP")
  field(OUTC, "XCOR:DOG:148:DEGAUSTYPE.PROC PP")
  field(OUTD, "XCOR:DOG:148:DEGAUSSTEP.PROC PP")
  field(OUTE, "XCOR:DOG:148:MADNAME.PROC PP")
  field(OUTF, "XCOR:DOG:148:PSTYPE.PROC PP")
  field(OUTG, "XCOR:DOG:148:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "XCOR:DOG:148:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:DOG:148:DEGAUSIMIN NPP NMS")
  field(INPB, "XCOR:DOG:148:DEGAUSIMAX NPP NMS")
  field(INPC, "XCOR:DOG:148:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "XCOR:DOG:148:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "XCOR:DOG:148:PSTYPE NPP NMS")
  field(INPG, "XCOR:DOG:148:DEBUG.RVAL NPP NMS")
  field(INPH, "XCOR:DOG:148:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "XCOR:DOG:148:DEGAUSWF PP")
  field(OUTB, "XCOR:DOG:148:DEGAUSMSG PP")
  field(OUTC, "XCOR:DOG:148:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "XCOR:DOG:148:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"XCOR:DOG:148:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "XCOR:DOG:148:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "XCOR:DOG:148:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "XCOR:DOG:148:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "XCOR:DOG:148:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "XCOR:DOG:148:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "-2")
}
record(ao, "XCOR:DOG:148:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"XCOR:DOG:148:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "XCOR:DOG:148:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"XCOR:DOG:148:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "XCOR:DOG:148:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "XCOR:DOG:148:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "XCOR:DOG:148:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "XCOR:DOG:148:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:DOG:148:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:148:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:DOG:148:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:DOG:148:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "XCOR:DOG:148:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "XCOR:DOG:148:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "XCOR:DOG:148:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "XCOR:DOG:148:DEGAUS_IMAX")
  field(INPB, "XCOR:DOG:148:ISETPT")
  field(INPC, "XCOR:DOG:148:DEGAUSTYPE.RVAL")
  field(OUT,  "XCOR:DOG:148:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "XCOR:DOG:148:DEGAUS_IMAX_UPDATE")
}
record(seq, "XCOR:DOG:148:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "XCOR:DOG:148:ISETPT")
  field(LNK1, "XCOR:DOG:148:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "XCOR:DOG:148:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:148:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "XCOR:DOG:148:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "XCOR:DOG:148:DEGAUS_IMAX")
  field(FLNK, "XCOR:DOG:148:DEGAUS_IMAXPOL")
}
record(bo, "XCOR:DOG:148:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:DOG:148:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "XCOR:DOG:148:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "XCOR:DOG:148:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "XCOR:DOG:148:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "XCOR:DOG:148:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "XCOR:DOG:148:IACT")
  field(INPB, "XCOR:DOG:148:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "XCOR:DOG:148:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "XCOR:DOG:148:IACTPOL")
}
record(bo, "XCOR:DOG:148:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"XCOR:DOG:148:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "XCOR:DOG:148:DEGAUSENABLE CP")
  field(INPB, "XCOR:DOG:148:DEGAUSOK")
  field(INPC, "XCOR:DOG:148:STATE CP")
  field(INPD, "XCOR:DOG:148:STATE.SEVR")
  field(OUT,  "XCOR:DOG:148:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "XCOR:DOG:148:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "XCOR:DOG:148:DEGAUS_STATE_CHECK")
  field(LNK1, "XCOR:DOG:148:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "XCOR:DOG:148:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "XCOR:DOG:148:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "XCOR:DOG:148:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "XCOR:DOG:148:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "XCOR:DOG:148:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:DOG:148:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "XCOR:DOG:148:STATMSG.FRSV")
  field(LNK4, "XCOR:DOG:148:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:DOG:148:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:148:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:DOG:148:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "XCOR:DOG:148:STATMSG.FRSV")
  field(LNK4, "XCOR:DOG:148:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:DOG:148:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "XCOR:DOG:148:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "XCOR:DOG:148:STATMSG.FRSV")
  field(LNK3, "XCOR:DOG:148:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "XCOR:DOG:148:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:148:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "XCOR:DOG:148:STATMSG.FRSV PP")
  field(LNK3, "XCOR:DOG:148:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "XCOR:DOG:148:FUNC") {
  field(DESC, "XCOR:DOG:148 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "XCOR:DOG:148:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:DOG:148:CTRL") {
  field(DESC, "XCOR:DOG:148 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "XCOR:DOG:148:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "XCOR:DOG:148:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "XCOR:DOG:148:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "XCOR:DOG:148:BUSY") {
  field(DESC, "XCOR:DOG:148 Ctrl Done")
  field(DOL, "XCOR:DOG:148:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:148:SELECT")
}

record(bo, "XCOR:DOG:148:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "XCOR:DOG:148:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:DOG:148:CTRLSTATE") {
  field(DESC, "XCOR:DOG:148 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("XCOR:DOG:148:CTRL",20,20,0,0,"XCOR:DOG:148:CTRL")
#! Field("XCOR:DOG:148:CTRL.OUT",16777215,1,"XCOR:DOG:148:CTRL.OUT")
#! Link("XCOR:DOG:148:CTRL.OUT","XCOR:DOG:148:SELECTEN.A")
#! Field("XCOR:DOG:148:CTRL.VAL",16777215,1,"XCOR:DOG:148:CTRL.VAL")
#! Record("XCOR:DOG:148:SELECTEN",321,381,0,0,"XCOR:DOG:148:SELECTEN")
#! Field("XCOR:DOG:148:SELECTEN.A",16777215,0,"XCOR:DOG:148:SELECTEN.A")
#! Field("XCOR:DOG:148:SELECTEN.FLNK",16777215,1,"XCOR:DOG:148:SELECTEN.FLNK")
#! Link("XCOR:DOG:148:SELECTEN.FLNK","XCOR:DOG:148:BUSY")
#! Field("XCOR:DOG:148:SELECTEN.VAL",16777215,1,"XCOR:DOG:148:SELECTEN.VAL")
#! Record("XCOR:DOG:148:BUSY",623,274,0,0,"XCOR:DOG:148:BUSY")
#! Field("XCOR:DOG:148:BUSY.DOL",16777215,0,"XCOR:DOG:148:BUSY.DOL")
#! Link("XCOR:DOG:148:BUSY.DOL","XCOR:DOG:148:SELECTEN.VAL")
#! Field("XCOR:DOG:148:BUSY.FLNK",16777215,1,"XCOR:DOG:148:BUSY.FLNK")
#! Link("XCOR:DOG:148:BUSY.FLNK","XCOR:DOG:148:SELECT")
#! Record("XCOR:DOG:148:SELECT",669,508,0,1,"XCOR:DOG:148:SELECT")
#! Record("XCOR:DOG:148:FUNC",940,120,0,0,"XCOR:DOG:148:FUNC")
#! Field("XCOR:DOG:148:FUNC.OUT",16777215,0,"XCOR:DOG:148:FUNC.OUT")
#! Link("XCOR:DOG:148:FUNC.OUT","XCOR:DOG:148:CTRL.VAL")
#! Record("XCOR:DOG:148:ABORT",193,41,0,0,"XCOR:DOG:148:ABORT")
#! Record("XCOR:DOG:148:CTRLSTATE",369,34,0,0,"XCOR:DOG:148:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"XCOR:DOG:148:SELECT is used for Multi-device selection.\nIt is enabled when associated XCOR:DOG:148:CTRL is \"0\" (DONE).\nIt is disabled when associated XCOR:DOG:148:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"XCOR:DOG:148:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "XCOR:DOG:148:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "XCOR:DOG:148:BCTRL.SEVR")
  field(OUT,  "XCOR:DOG:148:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "XCOR:DOG:148:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:DOG:148:BACT")
  field(INPB, "XCOR:DOG:148:POLYCOEF")
  field(INPC, "XCOR:DOG:148:POLYCOEF.A")
  field(INPD, "XCOR:DOG:148:POLYCOEF.B")
  field(INPE, "XCOR:DOG:148:IACT MS")
  field(INPF, "XCOR:DOG:148:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
  field(FLNK, "XCOR:DOG:148:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "XCOR:DOG:148:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:DOG:148:BDES")
  field(INPB, "XCOR:DOG:148:TRIMBTOL")
  field(INPC, "XCOR:DOG:148:TRIMBTOLR")
  field(INPD, "XCOR:DOG:148:CHCKBTOL")
  field(INPE, "XCOR:DOG:148:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "XCOR:DOG:148:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "XCOR:DOG:148:MPSBTOL")
  field(INPQ, "XCOR:DOG:148:MPSBTOLR")
  field(FLNK, "XCOR:DOG:148:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "XCOR:DOG:148:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "XCOR:DOG:148:BDES")
  field(INPB, "XCOR:DOG:148:BDELTAS.I")
  field(INPG, "XCOR:DOG:148:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "XCOR:DOG:148:BCON.HIGH")
  field(OUTB, "XCOR:DOG:148:BCON.LOW")
  field(OUTC, "XCOR:DOG:148:BCON.HIHI")
  field(OUTD, "XCOR:DOG:148:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:148:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "XCOR:DOG:148:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:DOG:148:BDIFF")
  field(LNK2, "XCOR:DOG:148:BADIFF")
  field(LNK3, "XCOR:DOG:148:BRATIO")
  field(LNK4, "XCOR:DOG:148:MPSLIMITS")
  field(LNK5, "XCOR:DOG:148:I2BSTATUS")
  field(LNK6, "XCOR:DOG:148:IACTFO.PROC")
}

record(calc, "XCOR:DOG:148:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:DOG:148:BDES")
  field(INPB, "XCOR:DOG:148:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "XCOR:DOG:148:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "XCOR:DOG:148:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "XCOR:DOG:148:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:DOG:148:BDIFF")
  field(INPB, "XCOR:DOG:148:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "XCOR:DOG:148:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "XCOR:DOG:148:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "XCOR:DOG:148:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:DOG:148:BMON")
  field(INPB, "XCOR:DOG:148:POLYCOEF")
  field(INPC, "XCOR:DOG:148:POLYCOEF.A")
  field(INPD, "XCOR:DOG:148:POLYCOEF.B")
  field(INPE, "XCOR:DOG:148:IMON MS")
  field(INPF, "XCOR:DOG:148:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:206:BDES CP
record(ao,  "XCOR:DOG:148:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.02098636")
   field(DRVL, "-0.02098636")
   field(HOPR, "0.02098636")
   field(LOPR, "-0.02098636")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "XCOR:DOG:148:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "XCOR:DOG:148:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:148:POLYCOEF")
  field(INPC, "XCOR:DOG:148:POLYCOEF.A")
  field(INPD, "XCOR:DOG:148:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "XCOR:DOG:148:BDES.DRVH")
  field(INPF, "XCOR:DOG:148:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:148:IDES")
}
record(sub, "XCOR:DOG:148:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:148:POLYCOEF")
  field(INPC, "XCOR:DOG:148:POLYCOEF.A")
  field(INPD, "XCOR:DOG:148:POLYCOEF.B")
  field(INPE, "XCOR:DOG:148:BDES.DRVH")
  field(INPF, "XCOR:DOG:148:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "XCOR:DOG:148:INOM")
}

record(sub, "XCOR:DOG:148:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:148:BDES.VAL")
  field(INPB, "XCOR:DOG:148:BDES.DRVH")
  field(INPC, "XCOR:DOG:148:BDES.DRVL")
  field(INPD, "XCOR:DOG:148:BDELTAS.I")
  field(INPE, "XCOR:DOG:148:BDELTAS.J")
  field(INPG, "XCOR:DOG:148:STATE")
  field(INPH, "XCOR:DOG:148:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:DOG:148:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:148:BDES.VAL")
  field(INPB, "XCOR:DOG:148:BDES.DRVH")
  field(INPC, "XCOR:DOG:148:BDES.DRVL")
  field(INPD, "XCOR:DOG:148:BDELTAS.K")
  field(INPE, "XCOR:DOG:148:BDELTAS.L")
  field(INPG, "XCOR:DOG:148:STATE")
  field(INPH, "XCOR:DOG:148:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:DOG:148:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "XCOR:DOG:148:BLIMITS")
  field(LNK1, "XCOR:DOG:148:BACTLIMITS.F PP")
  field(DOL2, "XCOR:DOG:148:BACTLIMITS.I")
  field(LNK2, "XCOR:DOG:148:BACT.HIGH")
  field(DOL3, "XCOR:DOG:148:BACTLIMITS.J")
  field(LNK3, "XCOR:DOG:148:BACT.LOW")
  field(DOL4, "XCOR:DOG:148:BACTLIMITS.K")
  field(LNK4, "XCOR:DOG:148:BACT.HIHI")
  field(DOL5, "XCOR:DOG:148:BACTLIMITS.L")
  field(LNK5, "XCOR:DOG:148:BACT.LOLO")
  field(DOL6, "XCOR:DOG:148:BLIMITS")
  field(LNK6, "XCOR:DOG:148:BMONLIMITS.F PP")
  field(DOL7, "XCOR:DOG:148:BMONLIMITS.I")
  field(LNK7, "XCOR:DOG:148:BMON.HIGH")
  field(DOL8, "XCOR:DOG:148:BMONLIMITS.J")
  field(LNK8, "XCOR:DOG:148:BMON.LOW")
  field(DOL9, "XCOR:DOG:148:BMONLIMITS.K")
  field(LNK9, "XCOR:DOG:148:BMON.HIHI")
  field(DOLA, "XCOR:DOG:148:BMONLIMITS.L")
  field(LNKA, "XCOR:DOG:148:BMON.LOLO")
  field(FLNK, "XCOR:DOG:148:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "XCOR:DOG:148:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "XCOR:DOG:148:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "XCOR:DOG:148:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:148:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "XCOR:DOG:148:BCTRL.VAL")
  field(LNK2, "XCOR:DOG:148:BDES PP")

  field(DOL3, "1")
  field(LNK3, "XCOR:DOG:148:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "XCOR:DOG:148:CHECKSTDZLOST.PROC PP")

  field(DOL5, "XCOR:DOG:148:BCTRL.VAL")
  field(LNK5, "XCOR:DOG:148:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "XCOR:DOG:148:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "XCOR:DOG:148:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:148:POLYCOEF")
  field(INPC, "XCOR:DOG:148:POLYCOEF.A")
  field(INPD, "XCOR:DOG:148:POLYCOEF.B")
  field(INPE, "XCOR:DOG:148:BDES.DRVH")
  field(INPF, "XCOR:DOG:148:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:148:ISETPT")
}

record(ao, "XCOR:DOG:148:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "XCOR:DOG:148:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "XCDOG3")
}

record(ai, "XCOR:DOG:148:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "691.087485")
}

record(ao, "XCOR:DOG:148:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(FLNK, "XCOR:DOG:148:BSTEP")
}

record(ao, "XCOR:DOG:148:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(FLNK, "XCOR:DOG:148:BSTEP")
}

record(ao, "XCOR:DOG:148:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by XCOR:DOG:148:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "XCOR:DOG:148:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "XCOR:DOG:148:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "XCOR:DOG:148:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:148:POLYCOEF")
  field(INPC, "XCOR:DOG:148:POLYCOEF.A")
  field(INPD, "XCOR:DOG:148:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "XCOR:DOG:148:BCON.DRVH")
  field(INPF, "XCOR:DOG:148:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:148:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "XCOR:DOG:148:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "XCOR:DOG:148:BMAX")
  field(INPB, "XCOR:DOG:148:BMIN")
  field(INPC, "XCOR:DOG:148:BMIN.SEVR")
  field(INPD, "XCOR:DOG:148:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"XCOR:DOG:148:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "XCOR:DOG:148:ONLINE CP")
  field(OUT,  "XCOR:DOG:148:BCTRLDISABLEFOUT PP")
}

record(fanout, "XCOR:DOG:148:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "XCOR:DOG:148:BCTRLDISABLECALC")
  field(LNK1, "XCOR:DOG:148:BCTRLDISABLE")
  field(LNK2, "XCOR:DOG:148:BCTRLENABLE")
}

record(stringout, "XCOR:DOG:148:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:DOG:148:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "XCOR:DOG:148:BCTRLDISV_UPDATE")
}

record(stringout, "XCOR:DOG:148:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:DOG:148:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "XCOR:DOG:148:BCTRLDISV_UPDATE")
}

record(calcout, "XCOR:DOG:148:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "XCOR:DOG:148:ONLINE")
  field(OUT,  "XCOR:DOG:148:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"XCOR:DOG:148:BACT and MON\n  are processed via links from \n  XCOR:DOG:148:IACT (device raw value readback 1)\n  and\n  XCOR:DOG:148:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from XCOR:DOG:148:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = XCOR:DOG:148:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"XCOR:DOG:148:BDES\n  is processed when set by CA users or \n  XCOR:DOG:148:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"XCOR:DOG:148:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  XCOR:DOG:148:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (XCOR:DOG:148:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"XCOR:DOG:148:B*LIMITS and XCOR:DOG:148:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:DOG:148:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"XCOR:DOG:148:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"XCOR:DOG:148:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "XCOR:DOG:148:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:148:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "XCOR:DOG:148:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "XCOR:DOG:148:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:148:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:148:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:148:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "XCOR:DOG:148:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "XCOR:DOG:148:MPSLIMITS.E PP")
}

record(aSub, "XCOR:DOG:148:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "XCOR:DOG:148:MPS.RVAL")
  field(INPB, "XCOR:DOG:148:BADIFF")
  field(INPC, "XCOR:DOG:148:BDELTAS.N")
  field(INPD, "XCOR:DOG:148:BACT")
  field(INPE, "XCOR:DOG:148:MPSBITMASK.RVAL")
  field(INPF, "XCOR:DOG:148:MPSBLLIM")
  field(INPG, "XCOR:DOG:148:MPSBMIN")
  field(INPH, "XCOR:DOG:148:MPSBMAX")
  field(INPI, "XCOR:DOG:148:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "XCOR:DOG:148:INTOL.RVAL PP")
  field(OUTB, "XCOR:DOG:148:INTOL_BMIN.RVAL PP")
  field(OUTC, "XCOR:DOG:148:INTOL_BRANGE.RVAL PP")
  field(OUTD, "XCOR:DOG:148:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "XCOR:DOG:148:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:148:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:148:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:148:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:148:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:148:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:148:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:148:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "XCOR:DOG:148:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "XCOR:DOG:148:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:DOG:148:CHCKBTOL")
  field(INPB, "XCOR:DOG:148:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "XCOR:DOG:148:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "XCOR:DOG:148:CHCKBTOL")
  field(FLNK, "XCOR:DOG:148:CHCKITOL")
}

record(calc, "XCOR:DOG:148:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "XCOR:DOG:148:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "XCOR:DOG:148:BDES.HOPR")
  field(INPB, "XCOR:DOG:148:STABILITY")
  field(INPC, "XCOR:DOG:148:BDES.LOPR")
}

record(longout, "XCOR:DOG:148:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "XCOR:DOG:148:CHCKBTOL")
}

record(calc, "XCOR:DOG:148:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:DOG:148:POLYCOEF.B")
  field(INPB, "XCOR:DOG:148:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "XCOR:DOG:148:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "XCOR:DOG:148:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "XCOR:DOG:148:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "XCOR:DOG:148:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "XCOR:DOG:148:PAUGO")  
}

record(fanout, "XCOR:DOG:148:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "XCOR:DOG:148:PAUSTOP")
  field(LNK2, "XCOR:DOG:148:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "XCOR:DOG:148:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "XCOR:DOG:148:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:206:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:206:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "XCOR:DOG:148:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "XCOR:DOG:148:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:206:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:206:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "XCOR:DOG:148:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:206:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:DOG:148:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "XCOR:DOG:148:PSTYPE.RVAL")
  field(INPC, "XCOR:DOG:148:TURNEDOFF.RVAL")
  field(INPD, "XCOR:DOG:148:CONFIG.RVAL")
  field(INPE, "XCOR:DOG:148:PSCATEGORY.RVAL")
  field(INPF, "XCOR:DOG:148:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "XCOR:DOG:148:AUTOCTRL.RVAL")
  field(INPJ, "XCOR:DOG:148:OUTOFSERVICE.RVAL")
  field(INPL, "XCOR:DOG:148:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "XCOR:DOG:148:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "XCOR:DOG:148:PAU")
  field(INPP, "XCOR:DOG:148:CALBDISABLE.RVAL")
  field(INPQ, "XCOR:DOG:148:PTRBDISABLE.RVAL")
  field(INPR, "XCOR:DOG:148:TRIMDISABLE.RVAL")
  field(INPS, "XCOR:DOG:148:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "XCOR:DOG:148:FBCK")
  field(INPU, "XCOR:DOG:148:TRIMTYPE.RVAL")
  field(INPV, "XCOR:DOG:148:STDZDIRECT.RVAL")
  field(INPW, "XCOR:DOG:148:DEGAUSENABLE.RVAL")
  field(FLNK, "XCOR:DOG:148:HSTA")
}

record(longin, "XCOR:DOG:148:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "XCOR:DOG:148:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "XCOR:DOG:148:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "XCOR:DOG:148:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "XCOR:DOG:148:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:148:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:148:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:148:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by XCOR:DOG:148:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses XCOR:DOG:148:FBCK.
# This PV should be replaced by XCOR:DOG:148:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "XCOR:DOG:148:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "XCOR:DOG:148:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:DOG:148:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:148:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"XCOR:DOG:148:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "XCOR:DOG:148:OUTOFSERVICE NPP NMS")
  field(OUT,  "XCOR:DOG:148:ONLINE PP")
}
record(bo, "XCOR:DOG:148:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "XCOR:DOG:148:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:DOG:148:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "XCOR:DOG:148:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "XCOR:DOG:148:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "XCOR:DOG:148:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "XCOR:DOG:148:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "XCOR:DOG:148:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "XCOR:DOG:148:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:148:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:148:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:148:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "XCOR:DOG:148:TRIMTYPE")
}

record(stringout, "XCOR:DOG:148:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "XCOR:DOG:148:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "XCOR:DOG:148:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "XCOR:DOG:148:STATE.RVAL")
  field(INPB, "XCOR:DOG:148:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:DOG:148:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:DOG:148:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "XCOR:DOG:148:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "XCOR:DOG:148:STATE.RVAL")
  field(INPB, "XCOR:DOG:148:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:DOG:148:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:DOG:148:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "XCOR:DOG:148:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "XCOR:DOG:148:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "XCOR:DOG:148:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "XCOR:DOG:148:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "XCOR:DOG:148:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"XCOR:DOG:148:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("XCOR:DOG:148:TURNEDOFF",3140,1907,0,1,"XCOR:DOG:148:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:DOG:148:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "XCOR:DOG:148:BACT.STAT")
  field(INPB, "XCOR:DOG:148:BDES.STAT")
  field(INPC, "XCOR:DOG:148:IRIPL.STAT")
  field(INPD, "MCOR:EXT:206:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:206:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "XCOR:DOG:148:BACT.SEVR")
  field(INPH, "XCOR:DOG:148:BDES.SEVR")
  field(INPI, "XCOR:DOG:148:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:206:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:206:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "XCOR:DOG:148:STATE.RVAL")
  field(INPN, "XCOR:DOG:148:STDZOK")
  field(INPO, "XCOR:DOG:148:CALBOK")
  field(INPP, "XCOR:DOG:148:OUTOFSERVICE.RVAL")
  field(INPQ, "XCOR:DOG:148:CONFIG.RVAL")
  field(INPR, "XCOR:DOG:148:HSTA")
  field(INPS, "XCOR:DOG:148:CTRL.RVAL")
  field(INPT, "XCOR:DOG:148:DEGAUSOK") 
  field(INPV, "XCOR:DOG:148:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:148:STAT")
}

record(longout, "XCOR:DOG:148:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "XCOR:DOG:148:STATCTRLSUB")
  field(DOL, "XCOR:DOG:148:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "XCOR:DOG:148:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "XCOR:DOG:148:STAT")
  field(INPB, "XCOR:DOG:148:HSTA")
  field(INPD, "XCOR:DOG:148:ONOFFCTRL.RVAL")
  field(FLNK, "XCOR:DOG:148:STATMSG")
}

record(mbbo, "XCOR:DOG:148:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:DOG:148:UNAVAILGO")
  field(DOL, "XCOR:DOG:148:STATCTRLSUB.W")
}

record(seq, "XCOR:DOG:148:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "XCOR:DOG:148:STATSUB.U")
  field(LNK1, "XCOR:DOG:148:UNAVAIL PP")
}

record(stringout, "XCOR:DOG:148:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"XCOR:DOG:148:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - XCOR:DOG:148:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - XCOR:DOG:148:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"XCOR:DOG:148STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - XCOR:DOG:148:STATUS\nC - XCOR:DOG:148:ON\nD - XCOR:DOG:148:STDZOK\nE - XCOR:DOG:148:CALBOK\nF - XCOR:DOG:148:BACTDRIFT (future)\nG -\nH- XCOR:DOG:148:DACSTATUS\nI -XCOR:DOG:148:ADCSTATUS\nJ - XCOR:DOG:148:BACTSTATUS\nK - XCOR:DOG:148:BDESSTATUS\nL - XCOR:DOG:148:RIPLSTATUS\n\nOutput:\nP - XCOR:DOG:148:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "XCOR:DOG:148:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "XCOR:DOG:148:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "XCOR:DOG:148:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "XCOR:DOG:148:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "YCOR:DOG:163:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:207:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:DOG:163:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "YCOR:DOG:163:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:207:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "YCOR:DOG:163:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "2")
  field(LOLO, "-2")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "YCOR:DOG:163:BDELTAS")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "YCOR:DOG:163:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "YCOR:DOG:163:ICTRL PP")
}

# This record is processed by YCOR:DOG:163:ICON")
# Note: we are not setting alarms here.
record(ao, "YCOR:DOG:163:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "YCOR:DOG:163:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:163:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "YCOR:DOG:163:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(ao, "YCOR:DOG:163:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(FLNK, "YCOR:DOG:163:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "YCOR:DOG:163:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "YCOR:DOG:163:ISETPT.OMSL")

  field(DOL2, "YCOR:DOG:163:ICTRL")
  field(LNK2, "YCOR:DOG:163:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "YCOR:DOG:163:ISETPT.OMSL")
}

record(ao, "YCOR:DOG:163:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:163:IMIN")
}

record(ao, "YCOR:DOG:163:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(VAL,  "-2")
  field(FLNK, "YCOR:DOG:163:IRANGE")
}

record(sel, "YCOR:DOG:163:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(NVL,  "YCOR:DOG:163:BACT.SEVR")
  field(INPA, "YCOR:DOG:163:IACT NPP MS")
  field(INPB, "YCOR:DOG:163:IACTPREVOK NPP MS")
  field(INPC, "YCOR:DOG:163:IACTPREVOK NPP MS")
  field(INPD, "YCOR:DOG:163:IACTPREVOK NPP MS")
}

record(sub, "YCOR:DOG:163:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:163:IDES")
  field(INPB, "YCOR:DOG:163:ISETPT.DRVH")
  field(INPC, "YCOR:DOG:163:ISETPT.DRVL")
  field(INPD, "YCOR:DOG:163:IDELTAS.I")
  field(INPE, "YCOR:DOG:163:IDELTAS.J")
  field(INPG, "YCOR:DOG:163:STATE")
  field(INPH, "YCOR:DOG:163:HSTA")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:DOG:163:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:163:IDES")
  field(INPB, "YCOR:DOG:163:ISETPT.DRVH")
  field(INPC, "YCOR:DOG:163:ISETPT.DRVL")
  field(INPD, "YCOR:DOG:163:IDELTAS.K")
  field(INPE, "YCOR:DOG:163:IDELTAS.L")
  field(INPG, "YCOR:DOG:163:STATE")
  field(INPH, "YCOR:DOG:163:HSTA")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:DOG:163:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "YCOR:DOG:163:BLIMITS")
  field(LNK1, "YCOR:DOG:163:IACTLIMITS.F PP")
  field(DOL2, "YCOR:DOG:163:IACTLIMITS.I")
  field(LNK2, "YCOR:DOG:163:IACT.HIGH")
  field(DOL3, "YCOR:DOG:163:IACTLIMITS.J")
  field(LNK3, "YCOR:DOG:163:IACT.LOW")
  field(DOL4, "YCOR:DOG:163:IACTLIMITS.K")
  field(LNK4, "YCOR:DOG:163:IACT.HIHI")
  field(DOL5, "YCOR:DOG:163:IACTLIMITS.L")
  field(LNK5, "YCOR:DOG:163:IACT.LOLO")
  field(DOL6, "YCOR:DOG:163:BLIMITS")
  field(LNK6, "YCOR:DOG:163:IMONLIMITS.F PP")
  field(DOL7, "YCOR:DOG:163:IMONLIMITS.I")
  field(LNK7, "YCOR:DOG:163:IMON.HIGH")
  field(DOL8, "YCOR:DOG:163:IMONLIMITS.J")
  field(LNK8, "YCOR:DOG:163:IMON.LOW")
  field(DOL9, "YCOR:DOG:163:IMONLIMITS.K")
  field(LNK9, "YCOR:DOG:163:IMON.HIHI")
  field(DOLA, "YCOR:DOG:163:IMONLIMITS.L")
  field(LNKA, "YCOR:DOG:163:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "YCOR:DOG:163:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "YCOR:DOG:163:TRIMBTOL")
  field(INPE, "YCOR:DOG:163:CHCKBTOL")
  field(INPF, "YCOR:DOG:163:BDELTAS.K")
  field(INPG, "YCOR:DOG:163:BDELTAS.L")
  field(INPH, "YCOR:DOG:163:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "YCOR:DOG:163:STDZITOLR")
  field(INPC, "YCOR:DOG:163:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:207:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "YCOR:DOG:163:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:207:RESET PP
#
record(bo, "YCOR:DOG:163:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:207:RESET PP")
}

record(bo, "YCOR:DOG:163:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:207:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "YCOR:DOG:163:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "YCOR:DOG:163:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:207:IRAMPRATE PP")
  field(FLNK, "YCOR:DOG:163:STDZDLY")
}


record(ao, "YCOR:DOG:163:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:207:ISETPT PP")
  field(DOL, "YCOR:DOG:163:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "YCOR:DOG:163:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:207:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:DOG:163:BMON")
}

record(ao, "YCOR:DOG:163:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:207:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "YCOR:DOG:163:IRIPLOK")
}

record(sub, "YCOR:DOG:163:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "YCOR:DOG:163:IRIPL.VAL")
  field(INPB, "YCOR:DOG:163:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:DOG:163:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:DOG:163:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "YCOR:DOG:163:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:207:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "YCOR:DOG:163:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:207:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "YCOR:DOG:163:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:DOG:163:IACTPREVOK")
  field(LNK2, "YCOR:DOG:163:IDIFF")
  field(LNK3, "YCOR:DOG:163:IADIFF")
  field(LNK4, "YCOR:DOG:163:IRATIO")
  field(LNK5, "YCOR:DOG:163:IDIRECT")
  field(LNK6, "YCOR:DOG:163:IACTPOL_CHECK")
}

record(calc, "YCOR:DOG:163:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:DOG:163:IDES")
  field(INPB, "YCOR:DOG:163:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(calc, "YCOR:DOG:163:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "YCOR:DOG:163:IDIFF")
  field(PREC, "9")
}

record(calc, "YCOR:DOG:163:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:DOG:163:IDIFF")
  field(INPB, "YCOR:DOG:163:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "YCOR:DOG:163:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "YCOR:DOG:163:IMIN")
  field(INPB,   "YCOR:DOG:163:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "YCOR:DOG:163:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "YCOR:DOG:163:IACT")
  field(INPB, "YCOR:DOG:163:IDES")
  field(INPC, "YCOR:DOG:163:ISETPT")
  field(INPD, "YCOR:DOG:163:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "YCOR:DOG:163:IADJUST PP")
}

record(bo, "YCOR:DOG:163:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "YCOR:DOG:163:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "YCOR:DOG:163:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "YCOR:DOG:163:IACT")
  field(FLNK, "YCOR:DOG:163:IACTPOL")
}
record(bo, "YCOR:DOG:163:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:DOG:163:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"YCOR:DOG:163:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:DOG:163:IDELTAS and the\n  YCOR:DOG:163:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"YCOR:DOG:163:IACT: \n  Get copy of YCOR:DOG:163:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"YCOR:DOG:163:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"YCOR:DOG:163:IDES:\n  Contains raw value calculated by \nYCOR:DOG:163:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nYCOR:DOG:163:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"YCOR:DOG:163:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  YCOR:DOG:163:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               YCOR:DOG:163:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"YCOR:DOG:163:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by YCOR:DOG:163:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, YCOR:DOG:163:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  YCOR:DOG:163:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "YCOR:DOG:163:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:163:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:DOG:163:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:DOG:163:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:DOG:163:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "YCOR:DOG:163:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "YCOR:DOG:163:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "YCOR:DOG:163:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "YCOR:DOG:163:TRIMTYPE.RVAL")
  field(INPB,   "YCOR:DOG:163:CONFIG.RVAL")
  field(OUT,    "YCOR:DOG:163:TRIMMAXNUM PP")
}
record(longout, "YCOR:DOG:163:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "YCOR:DOG:163:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "YCOR:DOG:163:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "YCOR:DOG:163:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "YCOR:DOG:163:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "YCOR:DOG:163:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "YCOR:DOG:163:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "YCOR:DOG:163:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "YCOR:DOG:163:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "YCOR:DOG:163:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "YCOR:DOG:163:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "YCOR:DOG:163:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "YCOR:DOG:163:IMOVE")
 field(INPB, "YCOR:DOG:163:IACT")
 field(INPC, "YCOR:DOG:163:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "YCOR:DOG:163:TRIMDLYPCT")
 field(INPF, "YCOR:DOG:163:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "YCOR:DOG:163:RAMPTIME_LEFT PP")
}

record(longout, "YCOR:DOG:163:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "YCOR:DOG:163:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "YCOR:DOG:163:RAMPDONE_CALC")
}

record(calc, "YCOR:DOG:163:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "YCOR:DOG:163:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "YCOR:DOG:163:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "YCOR:DOG:163:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:DOG:163:RAMPTIME_LEFT")
 field(OUT,  "YCOR:DOG:163:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "YCOR:DOG:163:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:DOG:163:RAMPTIME_LEFT NMS")
 field(OUT,  "YCOR:DOG:163:RAMPDONE PP")
}

record(bo, "YCOR:DOG:163:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "YCOR:DOG:163:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "YCOR:DOG:163:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "YCOR:DOG:163:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:163:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "YCOR:DOG:163:DEBUG.PROC PP")
  field(LNK2, "YCOR:DOG:163:STDZCYCLENUM.PROC PP")
  field(LNK3, "YCOR:DOG:163:STDZDISABLE.PROC PP")
  field(LNK4, "YCOR:DOG:163:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "YCOR:DOG:163:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "YCOR:DOG:163:STDZIMIN NPP NMS")
  field(INPB, "YCOR:DOG:163:STDZIMAX NPP NMS")
  field(INPC, "YCOR:DOG:163:STDZIFINAL NPP NMS")
  field(INPD, "YCOR:DOG:163:STDZCYCLENUM NPP NMS")
  field(INPE, "YCOR:DOG:163:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "YCOR:DOG:163:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "YCOR:DOG:163:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "YCOR:DOG:163:STDZWF PP")
  field(OUTB, "YCOR:DOG:163:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "YCOR:DOG:163:STDZWF")
}

record(mbbo, "YCOR:DOG:163:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "YCOR:DOG:163:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "YCOR:DOG:163:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "YCOR:DOG:163:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "YCOR:DOG:163:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "YCOR:DOG:163:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "YCOR:DOG:163:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:DOG:163:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:DOG:163:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "YCOR:DOG:163:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:163:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "YCOR:DOG:163:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "YCOR:DOG:163:STDZIMIN")
}

record(ao, "YCOR:DOG:163:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "YCOR:DOG:163:STDZIMAX")
}

record(ao, "YCOR:DOG:163:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:163:STDZIFINAL")
}

record(ao, "YCOR:DOG:163:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "YCOR:DOG:163:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "YCOR:DOG:163:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "YCOR:DOG:163:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "YCOR:DOG:163:STDZIMIN CP NMS")
  field(INPB, "YCOR:DOG:163:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "YCOR:DOG:163:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "YCOR:DOG:163:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "YCOR:DOG:163:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "YCOR:DOG:163:STDZIMIN CP NMS")
  field(INPB, "YCOR:DOG:163:STDZIMAX CP NMS")
  field(INPC, "YCOR:DOG:163:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:163:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "YCOR:DOG:163:TRIMDLYPCT CP MS")
  field(INPB, "YCOR:DOG:163:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "YCOR:DOG:163:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "YCOR:DOG:163:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:163:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "YCOR:DOG:163:IDES.HOPR")
  field(INPB, "YCOR:DOG:163:STDZMINIPCT CPP NMS")
  field(INPC, "YCOR:DOG:163:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "YCOR:DOG:163:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "YCOR:DOG:163:IDES.HOPR")
  field(INPB, "YCOR:DOG:163:IDES.LOPR")
  field(INPC, "YCOR:DOG:163:STDZDIRECT.RVAL")
  field(INPD, "YCOR:DOG:163:STDZMINIDELTA")
  field(INPE, "YCOR:DOG:163:IDES")
  field(PREC, "5")
  field(FLNK, "YCOR:DOG:163:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "YCOR:DOG:163:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "YCOR:DOG:163:IDES.HOPR")
  field(INPB, "YCOR:DOG:163:IDES.LOPR")
  field(INPC, "YCOR:DOG:163:STDZDIRECT.RVAL")
  field(INPD, "YCOR:DOG:163:STDZMINIDELTA")
  field(INPE, "YCOR:DOG:163:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "YCOR:DOG:163:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "YCOR:DOG:163:IADJUST.RVAL")
  field(INPB, "YCOR:DOG:163:STDZDIRECT.RVAL")
  field(INPC, "YCOR:DOG:163:STDZOK.RVAL")
  field(INPD, "YCOR:DOG:163:STDZDISABLE.RVAL")
  field(INPE, "YCOR:DOG:163:STATE.RVAL CPP NMS")
  field(INPF, "YCOR:DOG:163:ICTRL.RVAL")
  field(INPG, "YCOR:DOG:163:STATE.SEVR")
  field(INPH, "YCOR:DOG:163:BDELTAS.M")
  field(INPI, "YCOR:DOG:163:IACT.SEVR")
  field(OUT,  "YCOR:DOG:163:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "YCOR:DOG:163:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "YCOR:DOG:163:STDZLOSTTOD.PROC")
  field(LNK2, "YCOR:DOG:163:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "YCOR:DOG:163:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:163:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:DOG:163:IACT CP")
  field(INPB, "YCOR:DOG:163:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "YCOR:DOG:163:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "YCOR:DOG:163:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:163:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:DOG:163:STDZIACTMAX")
  field(INPB, "YCOR:DOG:163:IACT")
  field(INPC, "YCOR:DOG:163:IDELTAS.I")
  field(OUT,  "YCOR:DOG:163:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "YCOR:DOG:163:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "YCOR:DOG:163:STDZOK.RVAL CP")
  field(INPB, "YCOR:DOG:163:STDZDISABLE.RVAL CP")
  field(INPC, "YCOR:DOG:163:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "YCOR:DOG:163:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "YCOR:DOG:163:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "YCOR:DOG:163:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "YCOR:DOG:163:CALBOK")
  field(INPB, "YCOR:DOG:163:CALBDISABLE")
  field(INPC, "YCOR:DOG:163:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "YCOR:DOG:163:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "YCOR:DOG:163:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "YCOR:DOG:163:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "YCOR:DOG:163:CALBSLOPE")
  field(DOL3, "YCOR:DOG:163:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "YCOR:DOG:163:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:163:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "YCOR:DOG:163:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "YCOR:DOG:163:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "YCOR:DOG:163:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "YCOR:DOG:163:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "YCOR:DOG:163:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:163:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "YCOR:DOG:163:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:163:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "YCOR:DOG:163:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "YCOR:DOG:163:IACT")
  field(INPD, "YCOR:DOG:163:DACSLOPE")
  field(INPE, "YCOR:DOG:163:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "YCOR:DOG:163:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "YCOR:DOG:163:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "2")
  field(HOPR, "2")
  field(DRVL, "-2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "YCOR:DOG:163:CALBIMAX")
}

record(ao, "YCOR:DOG:163:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "2")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:163:CALBSTEPNUM")
}

record(ao, "YCOR:DOG:163:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL, "0")
}

record(longout, "YCOR:DOG:163:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:DOG:163:CALBIDELTA")
}

record(calc, "YCOR:DOG:163:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "YCOR:DOG:163:CALBIMAX")
  field(INPB, "YCOR:DOG:163:CALBIMIN")
  field(INPC, "YCOR:DOG:163:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "YCOR:DOG:163:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:207:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:207:IACT.HOPR")
  field(INPC, "YCOR:DOG:163:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "YCOR:DOG:163:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:DOG:163:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:163:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:163:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:163:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "YCOR:DOG:163:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:163:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:163:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:163:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "YCOR:DOG:163:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:163:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:163:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:163:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:DOG:163:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:163:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:163:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "YCOR:DOG:163:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:163:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "YCOR:DOG:163:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "YCOR:DOG:163:CALBSTEPNUM")
  field(INPB, "YCOR:DOG:163:CALBIACTWF")
  field(INPC, "YCOR:DOG:163:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "YCOR:DOG:163:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "YCOR:DOG:163:STDZITOL")

  field(INPH, "YCOR:DOG:163:DACSLOPE")
  field(INPI, "YCOR:DOG:163:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "YCOR:DOG:163:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "YCOR:DOG:163:CALBSTEPNUM")
  field(INPB, "YCOR:DOG:163:CALBIACTWF")
  field(INPC, "YCOR:DOG:163:DACWF")
  field(INPF, "YCOR:DOG:163:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe YCOR:DOG:163CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "YCOR:DOG:163:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "YCOR:DOG:163:DEGAUSIMIN.PROC PP")
  field(OUTB, "YCOR:DOG:163:DEGAUSIMAX.PROC PP")
  field(OUTC, "YCOR:DOG:163:DEGAUSTYPE.PROC PP")
  field(OUTD, "YCOR:DOG:163:DEGAUSSTEP.PROC PP")
  field(OUTE, "YCOR:DOG:163:MADNAME.PROC PP")
  field(OUTF, "YCOR:DOG:163:PSTYPE.PROC PP")
  field(OUTG, "YCOR:DOG:163:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "YCOR:DOG:163:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:DOG:163:DEGAUSIMIN NPP NMS")
  field(INPB, "YCOR:DOG:163:DEGAUSIMAX NPP NMS")
  field(INPC, "YCOR:DOG:163:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "YCOR:DOG:163:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "YCOR:DOG:163:PSTYPE NPP NMS")
  field(INPG, "YCOR:DOG:163:DEBUG.RVAL NPP NMS")
  field(INPH, "YCOR:DOG:163:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "YCOR:DOG:163:DEGAUSWF PP")
  field(OUTB, "YCOR:DOG:163:DEGAUSMSG PP")
  field(OUTC, "YCOR:DOG:163:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "YCOR:DOG:163:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"YCOR:DOG:163:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "YCOR:DOG:163:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "YCOR:DOG:163:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "YCOR:DOG:163:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "YCOR:DOG:163:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "YCOR:DOG:163:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "-2")
}
record(ao, "YCOR:DOG:163:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"YCOR:DOG:163:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "YCOR:DOG:163:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"YCOR:DOG:163:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "YCOR:DOG:163:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "YCOR:DOG:163:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "YCOR:DOG:163:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "YCOR:DOG:163:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:DOG:163:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:163:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:DOG:163:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:DOG:163:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "YCOR:DOG:163:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "YCOR:DOG:163:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "YCOR:DOG:163:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "YCOR:DOG:163:DEGAUS_IMAX")
  field(INPB, "YCOR:DOG:163:ISETPT")
  field(INPC, "YCOR:DOG:163:DEGAUSTYPE.RVAL")
  field(OUT,  "YCOR:DOG:163:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "YCOR:DOG:163:DEGAUS_IMAX_UPDATE")
}
record(seq, "YCOR:DOG:163:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "YCOR:DOG:163:ISETPT")
  field(LNK1, "YCOR:DOG:163:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "YCOR:DOG:163:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:163:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "YCOR:DOG:163:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "YCOR:DOG:163:DEGAUS_IMAX")
  field(FLNK, "YCOR:DOG:163:DEGAUS_IMAXPOL")
}
record(bo, "YCOR:DOG:163:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:DOG:163:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "YCOR:DOG:163:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "YCOR:DOG:163:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "YCOR:DOG:163:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "YCOR:DOG:163:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "YCOR:DOG:163:IACT")
  field(INPB, "YCOR:DOG:163:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "YCOR:DOG:163:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "YCOR:DOG:163:IACTPOL")
}
record(bo, "YCOR:DOG:163:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"YCOR:DOG:163:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "YCOR:DOG:163:DEGAUSENABLE CP")
  field(INPB, "YCOR:DOG:163:DEGAUSOK")
  field(INPC, "YCOR:DOG:163:STATE CP")
  field(INPD, "YCOR:DOG:163:STATE.SEVR")
  field(OUT,  "YCOR:DOG:163:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "YCOR:DOG:163:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "YCOR:DOG:163:DEGAUS_STATE_CHECK")
  field(LNK1, "YCOR:DOG:163:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "YCOR:DOG:163:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "YCOR:DOG:163:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "YCOR:DOG:163:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "YCOR:DOG:163:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "YCOR:DOG:163:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:DOG:163:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "YCOR:DOG:163:STATMSG.FRSV")
  field(LNK4, "YCOR:DOG:163:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:DOG:163:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:163:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:DOG:163:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "YCOR:DOG:163:STATMSG.FRSV")
  field(LNK4, "YCOR:DOG:163:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:DOG:163:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "YCOR:DOG:163:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "YCOR:DOG:163:STATMSG.FRSV")
  field(LNK3, "YCOR:DOG:163:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "YCOR:DOG:163:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:163:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "YCOR:DOG:163:STATMSG.FRSV PP")
  field(LNK3, "YCOR:DOG:163:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "YCOR:DOG:163:FUNC") {
  field(DESC, "YCOR:DOG:163 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "YCOR:DOG:163:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:DOG:163:CTRL") {
  field(DESC, "YCOR:DOG:163 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "YCOR:DOG:163:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "YCOR:DOG:163:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "YCOR:DOG:163:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "YCOR:DOG:163:BUSY") {
  field(DESC, "YCOR:DOG:163 Ctrl Done")
  field(DOL, "YCOR:DOG:163:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:163:SELECT")
}

record(bo, "YCOR:DOG:163:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "YCOR:DOG:163:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:DOG:163:CTRLSTATE") {
  field(DESC, "YCOR:DOG:163 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("YCOR:DOG:163:CTRL",20,20,0,0,"YCOR:DOG:163:CTRL")
#! Field("YCOR:DOG:163:CTRL.OUT",16777215,1,"YCOR:DOG:163:CTRL.OUT")
#! Link("YCOR:DOG:163:CTRL.OUT","YCOR:DOG:163:SELECTEN.A")
#! Field("YCOR:DOG:163:CTRL.VAL",16777215,1,"YCOR:DOG:163:CTRL.VAL")
#! Record("YCOR:DOG:163:SELECTEN",321,381,0,0,"YCOR:DOG:163:SELECTEN")
#! Field("YCOR:DOG:163:SELECTEN.A",16777215,0,"YCOR:DOG:163:SELECTEN.A")
#! Field("YCOR:DOG:163:SELECTEN.FLNK",16777215,1,"YCOR:DOG:163:SELECTEN.FLNK")
#! Link("YCOR:DOG:163:SELECTEN.FLNK","YCOR:DOG:163:BUSY")
#! Field("YCOR:DOG:163:SELECTEN.VAL",16777215,1,"YCOR:DOG:163:SELECTEN.VAL")
#! Record("YCOR:DOG:163:BUSY",623,274,0,0,"YCOR:DOG:163:BUSY")
#! Field("YCOR:DOG:163:BUSY.DOL",16777215,0,"YCOR:DOG:163:BUSY.DOL")
#! Link("YCOR:DOG:163:BUSY.DOL","YCOR:DOG:163:SELECTEN.VAL")
#! Field("YCOR:DOG:163:BUSY.FLNK",16777215,1,"YCOR:DOG:163:BUSY.FLNK")
#! Link("YCOR:DOG:163:BUSY.FLNK","YCOR:DOG:163:SELECT")
#! Record("YCOR:DOG:163:SELECT",669,508,0,1,"YCOR:DOG:163:SELECT")
#! Record("YCOR:DOG:163:FUNC",940,120,0,0,"YCOR:DOG:163:FUNC")
#! Field("YCOR:DOG:163:FUNC.OUT",16777215,0,"YCOR:DOG:163:FUNC.OUT")
#! Link("YCOR:DOG:163:FUNC.OUT","YCOR:DOG:163:CTRL.VAL")
#! Record("YCOR:DOG:163:ABORT",193,41,0,0,"YCOR:DOG:163:ABORT")
#! Record("YCOR:DOG:163:CTRLSTATE",369,34,0,0,"YCOR:DOG:163:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"YCOR:DOG:163:SELECT is used for Multi-device selection.\nIt is enabled when associated YCOR:DOG:163:CTRL is \"0\" (DONE).\nIt is disabled when associated YCOR:DOG:163:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"YCOR:DOG:163:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "YCOR:DOG:163:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "YCOR:DOG:163:BCTRL.SEVR")
  field(OUT,  "YCOR:DOG:163:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "YCOR:DOG:163:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:DOG:163:BACT")
  field(INPB, "YCOR:DOG:163:POLYCOEF")
  field(INPC, "YCOR:DOG:163:POLYCOEF.A")
  field(INPD, "YCOR:DOG:163:POLYCOEF.B")
  field(INPE, "YCOR:DOG:163:IACT MS")
  field(INPF, "YCOR:DOG:163:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
  field(FLNK, "YCOR:DOG:163:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "YCOR:DOG:163:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:DOG:163:BDES")
  field(INPB, "YCOR:DOG:163:TRIMBTOL")
  field(INPC, "YCOR:DOG:163:TRIMBTOLR")
  field(INPD, "YCOR:DOG:163:CHCKBTOL")
  field(INPE, "YCOR:DOG:163:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "YCOR:DOG:163:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "YCOR:DOG:163:MPSBTOL")
  field(INPQ, "YCOR:DOG:163:MPSBTOLR")
  field(FLNK, "YCOR:DOG:163:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "YCOR:DOG:163:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "YCOR:DOG:163:BDES")
  field(INPB, "YCOR:DOG:163:BDELTAS.I")
  field(INPG, "YCOR:DOG:163:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "YCOR:DOG:163:BCON.HIGH")
  field(OUTB, "YCOR:DOG:163:BCON.LOW")
  field(OUTC, "YCOR:DOG:163:BCON.HIHI")
  field(OUTD, "YCOR:DOG:163:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:163:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "YCOR:DOG:163:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:DOG:163:BDIFF")
  field(LNK2, "YCOR:DOG:163:BADIFF")
  field(LNK3, "YCOR:DOG:163:BRATIO")
  field(LNK4, "YCOR:DOG:163:MPSLIMITS")
  field(LNK5, "YCOR:DOG:163:I2BSTATUS")
  field(LNK6, "YCOR:DOG:163:IACTFO.PROC")
}

record(calc, "YCOR:DOG:163:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:DOG:163:BDES")
  field(INPB, "YCOR:DOG:163:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "YCOR:DOG:163:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "YCOR:DOG:163:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "YCOR:DOG:163:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:DOG:163:BDIFF")
  field(INPB, "YCOR:DOG:163:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "YCOR:DOG:163:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "YCOR:DOG:163:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "YCOR:DOG:163:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:DOG:163:BMON")
  field(INPB, "YCOR:DOG:163:POLYCOEF")
  field(INPC, "YCOR:DOG:163:POLYCOEF.A")
  field(INPD, "YCOR:DOG:163:POLYCOEF.B")
  field(INPE, "YCOR:DOG:163:IMON MS")
  field(INPF, "YCOR:DOG:163:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:207:BDES CP
record(ao,  "YCOR:DOG:163:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.02098636")
   field(DRVL, "-0.02098636")
   field(HOPR, "0.02098636")
   field(LOPR, "-0.02098636")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "YCOR:DOG:163:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "YCOR:DOG:163:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:163:POLYCOEF")
  field(INPC, "YCOR:DOG:163:POLYCOEF.A")
  field(INPD, "YCOR:DOG:163:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "YCOR:DOG:163:BDES.DRVH")
  field(INPF, "YCOR:DOG:163:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:163:IDES")
}
record(sub, "YCOR:DOG:163:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:163:POLYCOEF")
  field(INPC, "YCOR:DOG:163:POLYCOEF.A")
  field(INPD, "YCOR:DOG:163:POLYCOEF.B")
  field(INPE, "YCOR:DOG:163:BDES.DRVH")
  field(INPF, "YCOR:DOG:163:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "YCOR:DOG:163:INOM")
}

record(sub, "YCOR:DOG:163:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:163:BDES.VAL")
  field(INPB, "YCOR:DOG:163:BDES.DRVH")
  field(INPC, "YCOR:DOG:163:BDES.DRVL")
  field(INPD, "YCOR:DOG:163:BDELTAS.I")
  field(INPE, "YCOR:DOG:163:BDELTAS.J")
  field(INPG, "YCOR:DOG:163:STATE")
  field(INPH, "YCOR:DOG:163:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:DOG:163:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:163:BDES.VAL")
  field(INPB, "YCOR:DOG:163:BDES.DRVH")
  field(INPC, "YCOR:DOG:163:BDES.DRVL")
  field(INPD, "YCOR:DOG:163:BDELTAS.K")
  field(INPE, "YCOR:DOG:163:BDELTAS.L")
  field(INPG, "YCOR:DOG:163:STATE")
  field(INPH, "YCOR:DOG:163:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:DOG:163:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "YCOR:DOG:163:BLIMITS")
  field(LNK1, "YCOR:DOG:163:BACTLIMITS.F PP")
  field(DOL2, "YCOR:DOG:163:BACTLIMITS.I")
  field(LNK2, "YCOR:DOG:163:BACT.HIGH")
  field(DOL3, "YCOR:DOG:163:BACTLIMITS.J")
  field(LNK3, "YCOR:DOG:163:BACT.LOW")
  field(DOL4, "YCOR:DOG:163:BACTLIMITS.K")
  field(LNK4, "YCOR:DOG:163:BACT.HIHI")
  field(DOL5, "YCOR:DOG:163:BACTLIMITS.L")
  field(LNK5, "YCOR:DOG:163:BACT.LOLO")
  field(DOL6, "YCOR:DOG:163:BLIMITS")
  field(LNK6, "YCOR:DOG:163:BMONLIMITS.F PP")
  field(DOL7, "YCOR:DOG:163:BMONLIMITS.I")
  field(LNK7, "YCOR:DOG:163:BMON.HIGH")
  field(DOL8, "YCOR:DOG:163:BMONLIMITS.J")
  field(LNK8, "YCOR:DOG:163:BMON.LOW")
  field(DOL9, "YCOR:DOG:163:BMONLIMITS.K")
  field(LNK9, "YCOR:DOG:163:BMON.HIHI")
  field(DOLA, "YCOR:DOG:163:BMONLIMITS.L")
  field(LNKA, "YCOR:DOG:163:BMON.LOLO")
  field(FLNK, "YCOR:DOG:163:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "YCOR:DOG:163:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "YCOR:DOG:163:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "YCOR:DOG:163:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:163:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "YCOR:DOG:163:BCTRL.VAL")
  field(LNK2, "YCOR:DOG:163:BDES PP")

  field(DOL3, "1")
  field(LNK3, "YCOR:DOG:163:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "YCOR:DOG:163:CHECKSTDZLOST.PROC PP")

  field(DOL5, "YCOR:DOG:163:BCTRL.VAL")
  field(LNK5, "YCOR:DOG:163:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "YCOR:DOG:163:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "YCOR:DOG:163:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:163:POLYCOEF")
  field(INPC, "YCOR:DOG:163:POLYCOEF.A")
  field(INPD, "YCOR:DOG:163:POLYCOEF.B")
  field(INPE, "YCOR:DOG:163:BDES.DRVH")
  field(INPF, "YCOR:DOG:163:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:163:ISETPT")
}

record(ao, "YCOR:DOG:163:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "YCOR:DOG:163:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "YCDOG4")
}

record(ai, "YCOR:DOG:163:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "700.712457")
}

record(ao, "YCOR:DOG:163:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(FLNK, "YCOR:DOG:163:BSTEP")
}

record(ao, "YCOR:DOG:163:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(FLNK, "YCOR:DOG:163:BSTEP")
}

record(ao, "YCOR:DOG:163:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by YCOR:DOG:163:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "YCOR:DOG:163:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "YCOR:DOG:163:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "YCOR:DOG:163:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:163:POLYCOEF")
  field(INPC, "YCOR:DOG:163:POLYCOEF.A")
  field(INPD, "YCOR:DOG:163:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "YCOR:DOG:163:BCON.DRVH")
  field(INPF, "YCOR:DOG:163:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:163:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "YCOR:DOG:163:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "YCOR:DOG:163:BMAX")
  field(INPB, "YCOR:DOG:163:BMIN")
  field(INPC, "YCOR:DOG:163:BMIN.SEVR")
  field(INPD, "YCOR:DOG:163:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"YCOR:DOG:163:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "YCOR:DOG:163:ONLINE CP")
  field(OUT,  "YCOR:DOG:163:BCTRLDISABLEFOUT PP")
}

record(fanout, "YCOR:DOG:163:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "YCOR:DOG:163:BCTRLDISABLECALC")
  field(LNK1, "YCOR:DOG:163:BCTRLDISABLE")
  field(LNK2, "YCOR:DOG:163:BCTRLENABLE")
}

record(stringout, "YCOR:DOG:163:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:DOG:163:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "YCOR:DOG:163:BCTRLDISV_UPDATE")
}

record(stringout, "YCOR:DOG:163:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:DOG:163:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "YCOR:DOG:163:BCTRLDISV_UPDATE")
}

record(calcout, "YCOR:DOG:163:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "YCOR:DOG:163:ONLINE")
  field(OUT,  "YCOR:DOG:163:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"YCOR:DOG:163:BACT and MON\n  are processed via links from \n  YCOR:DOG:163:IACT (device raw value readback 1)\n  and\n  YCOR:DOG:163:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from YCOR:DOG:163:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = YCOR:DOG:163:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"YCOR:DOG:163:BDES\n  is processed when set by CA users or \n  YCOR:DOG:163:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"YCOR:DOG:163:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  YCOR:DOG:163:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (YCOR:DOG:163:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"YCOR:DOG:163:B*LIMITS and YCOR:DOG:163:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:DOG:163:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"YCOR:DOG:163:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"YCOR:DOG:163:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "YCOR:DOG:163:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:163:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "YCOR:DOG:163:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "YCOR:DOG:163:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:163:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:163:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:163:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "YCOR:DOG:163:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "YCOR:DOG:163:MPSLIMITS.E PP")
}

record(aSub, "YCOR:DOG:163:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "YCOR:DOG:163:MPS.RVAL")
  field(INPB, "YCOR:DOG:163:BADIFF")
  field(INPC, "YCOR:DOG:163:BDELTAS.N")
  field(INPD, "YCOR:DOG:163:BACT")
  field(INPE, "YCOR:DOG:163:MPSBITMASK.RVAL")
  field(INPF, "YCOR:DOG:163:MPSBLLIM")
  field(INPG, "YCOR:DOG:163:MPSBMIN")
  field(INPH, "YCOR:DOG:163:MPSBMAX")
  field(INPI, "YCOR:DOG:163:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "YCOR:DOG:163:INTOL.RVAL PP")
  field(OUTB, "YCOR:DOG:163:INTOL_BMIN.RVAL PP")
  field(OUTC, "YCOR:DOG:163:INTOL_BRANGE.RVAL PP")
  field(OUTD, "YCOR:DOG:163:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "YCOR:DOG:163:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:163:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:163:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:163:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:163:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:163:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:163:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:163:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "YCOR:DOG:163:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "YCOR:DOG:163:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:DOG:163:CHCKBTOL")
  field(INPB, "YCOR:DOG:163:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "YCOR:DOG:163:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "YCOR:DOG:163:CHCKBTOL")
  field(FLNK, "YCOR:DOG:163:CHCKITOL")
}

record(calc, "YCOR:DOG:163:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "YCOR:DOG:163:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "YCOR:DOG:163:BDES.HOPR")
  field(INPB, "YCOR:DOG:163:STABILITY")
  field(INPC, "YCOR:DOG:163:BDES.LOPR")
}

record(longout, "YCOR:DOG:163:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "YCOR:DOG:163:CHCKBTOL")
}

record(calc, "YCOR:DOG:163:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:DOG:163:POLYCOEF.B")
  field(INPB, "YCOR:DOG:163:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "YCOR:DOG:163:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "YCOR:DOG:163:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "YCOR:DOG:163:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "YCOR:DOG:163:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "YCOR:DOG:163:PAUGO")  
}

record(fanout, "YCOR:DOG:163:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "YCOR:DOG:163:PAUSTOP")
  field(LNK2, "YCOR:DOG:163:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "YCOR:DOG:163:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "YCOR:DOG:163:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:207:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:207:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "YCOR:DOG:163:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "YCOR:DOG:163:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:207:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:207:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "YCOR:DOG:163:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:207:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:DOG:163:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "YCOR:DOG:163:PSTYPE.RVAL")
  field(INPC, "YCOR:DOG:163:TURNEDOFF.RVAL")
  field(INPD, "YCOR:DOG:163:CONFIG.RVAL")
  field(INPE, "YCOR:DOG:163:PSCATEGORY.RVAL")
  field(INPF, "YCOR:DOG:163:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "YCOR:DOG:163:AUTOCTRL.RVAL")
  field(INPJ, "YCOR:DOG:163:OUTOFSERVICE.RVAL")
  field(INPL, "YCOR:DOG:163:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "YCOR:DOG:163:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "YCOR:DOG:163:PAU")
  field(INPP, "YCOR:DOG:163:CALBDISABLE.RVAL")
  field(INPQ, "YCOR:DOG:163:PTRBDISABLE.RVAL")
  field(INPR, "YCOR:DOG:163:TRIMDISABLE.RVAL")
  field(INPS, "YCOR:DOG:163:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "YCOR:DOG:163:FBCK")
  field(INPU, "YCOR:DOG:163:TRIMTYPE.RVAL")
  field(INPV, "YCOR:DOG:163:STDZDIRECT.RVAL")
  field(INPW, "YCOR:DOG:163:DEGAUSENABLE.RVAL")
  field(FLNK, "YCOR:DOG:163:HSTA")
}

record(longin, "YCOR:DOG:163:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "YCOR:DOG:163:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "YCOR:DOG:163:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "YCOR:DOG:163:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "YCOR:DOG:163:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:163:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:163:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:163:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by YCOR:DOG:163:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses YCOR:DOG:163:FBCK.
# This PV should be replaced by YCOR:DOG:163:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "YCOR:DOG:163:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "YCOR:DOG:163:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:DOG:163:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:163:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"YCOR:DOG:163:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "YCOR:DOG:163:OUTOFSERVICE NPP NMS")
  field(OUT,  "YCOR:DOG:163:ONLINE PP")
}
record(bo, "YCOR:DOG:163:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "YCOR:DOG:163:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:DOG:163:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "YCOR:DOG:163:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "YCOR:DOG:163:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "YCOR:DOG:163:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "YCOR:DOG:163:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "YCOR:DOG:163:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "YCOR:DOG:163:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:163:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:163:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:163:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "YCOR:DOG:163:TRIMTYPE")
}

record(stringout, "YCOR:DOG:163:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "YCOR:DOG:163:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "YCOR:DOG:163:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "YCOR:DOG:163:STATE.RVAL")
  field(INPB, "YCOR:DOG:163:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:DOG:163:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:DOG:163:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "YCOR:DOG:163:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "YCOR:DOG:163:STATE.RVAL")
  field(INPB, "YCOR:DOG:163:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:DOG:163:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:DOG:163:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "YCOR:DOG:163:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "YCOR:DOG:163:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "YCOR:DOG:163:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "YCOR:DOG:163:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "YCOR:DOG:163:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"YCOR:DOG:163:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("YCOR:DOG:163:TURNEDOFF",3140,1907,0,1,"YCOR:DOG:163:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:DOG:163:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "YCOR:DOG:163:BACT.STAT")
  field(INPB, "YCOR:DOG:163:BDES.STAT")
  field(INPC, "YCOR:DOG:163:IRIPL.STAT")
  field(INPD, "MCOR:EXT:207:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:207:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "YCOR:DOG:163:BACT.SEVR")
  field(INPH, "YCOR:DOG:163:BDES.SEVR")
  field(INPI, "YCOR:DOG:163:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:207:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:207:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "YCOR:DOG:163:STATE.RVAL")
  field(INPN, "YCOR:DOG:163:STDZOK")
  field(INPO, "YCOR:DOG:163:CALBOK")
  field(INPP, "YCOR:DOG:163:OUTOFSERVICE.RVAL")
  field(INPQ, "YCOR:DOG:163:CONFIG.RVAL")
  field(INPR, "YCOR:DOG:163:HSTA")
  field(INPS, "YCOR:DOG:163:CTRL.RVAL")
  field(INPT, "YCOR:DOG:163:DEGAUSOK") 
  field(INPV, "YCOR:DOG:163:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:163:STAT")
}

record(longout, "YCOR:DOG:163:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "YCOR:DOG:163:STATCTRLSUB")
  field(DOL, "YCOR:DOG:163:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "YCOR:DOG:163:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "YCOR:DOG:163:STAT")
  field(INPB, "YCOR:DOG:163:HSTA")
  field(INPD, "YCOR:DOG:163:ONOFFCTRL.RVAL")
  field(FLNK, "YCOR:DOG:163:STATMSG")
}

record(mbbo, "YCOR:DOG:163:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:DOG:163:UNAVAILGO")
  field(DOL, "YCOR:DOG:163:STATCTRLSUB.W")
}

record(seq, "YCOR:DOG:163:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "YCOR:DOG:163:STATSUB.U")
  field(LNK1, "YCOR:DOG:163:UNAVAIL PP")
}

record(stringout, "YCOR:DOG:163:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"YCOR:DOG:163:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - YCOR:DOG:163:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - YCOR:DOG:163:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"YCOR:DOG:163STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - YCOR:DOG:163:STATUS\nC - YCOR:DOG:163:ON\nD - YCOR:DOG:163:STDZOK\nE - YCOR:DOG:163:CALBOK\nF - YCOR:DOG:163:BACTDRIFT (future)\nG -\nH- YCOR:DOG:163:DACSTATUS\nI -YCOR:DOG:163:ADCSTATUS\nJ - YCOR:DOG:163:BACTSTATUS\nK - YCOR:DOG:163:BDESSTATUS\nL - YCOR:DOG:163:RIPLSTATUS\n\nOutput:\nP - YCOR:DOG:163:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "YCOR:DOG:163:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "YCOR:DOG:163:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "YCOR:DOG:163:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "YCOR:DOG:163:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "XCOR:DOG:178:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:208:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:DOG:178:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "XCOR:DOG:178:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:208:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "XCOR:DOG:178:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "2")
  field(LOLO, "-2")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "XCOR:DOG:178:BDELTAS")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "XCOR:DOG:178:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "XCOR:DOG:178:ICTRL PP")
}

# This record is processed by XCOR:DOG:178:ICON")
# Note: we are not setting alarms here.
record(ao, "XCOR:DOG:178:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "XCOR:DOG:178:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:178:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "XCOR:DOG:178:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(ao, "XCOR:DOG:178:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(FLNK, "XCOR:DOG:178:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "XCOR:DOG:178:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "XCOR:DOG:178:ISETPT.OMSL")

  field(DOL2, "XCOR:DOG:178:ICTRL")
  field(LNK2, "XCOR:DOG:178:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "XCOR:DOG:178:ISETPT.OMSL")
}

record(ao, "XCOR:DOG:178:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:178:IMIN")
}

record(ao, "XCOR:DOG:178:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(VAL,  "-2")
  field(FLNK, "XCOR:DOG:178:IRANGE")
}

record(sel, "XCOR:DOG:178:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(NVL,  "XCOR:DOG:178:BACT.SEVR")
  field(INPA, "XCOR:DOG:178:IACT NPP MS")
  field(INPB, "XCOR:DOG:178:IACTPREVOK NPP MS")
  field(INPC, "XCOR:DOG:178:IACTPREVOK NPP MS")
  field(INPD, "XCOR:DOG:178:IACTPREVOK NPP MS")
}

record(sub, "XCOR:DOG:178:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:178:IDES")
  field(INPB, "XCOR:DOG:178:ISETPT.DRVH")
  field(INPC, "XCOR:DOG:178:ISETPT.DRVL")
  field(INPD, "XCOR:DOG:178:IDELTAS.I")
  field(INPE, "XCOR:DOG:178:IDELTAS.J")
  field(INPG, "XCOR:DOG:178:STATE")
  field(INPH, "XCOR:DOG:178:HSTA")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:DOG:178:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:178:IDES")
  field(INPB, "XCOR:DOG:178:ISETPT.DRVH")
  field(INPC, "XCOR:DOG:178:ISETPT.DRVL")
  field(INPD, "XCOR:DOG:178:IDELTAS.K")
  field(INPE, "XCOR:DOG:178:IDELTAS.L")
  field(INPG, "XCOR:DOG:178:STATE")
  field(INPH, "XCOR:DOG:178:HSTA")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:DOG:178:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "XCOR:DOG:178:BLIMITS")
  field(LNK1, "XCOR:DOG:178:IACTLIMITS.F PP")
  field(DOL2, "XCOR:DOG:178:IACTLIMITS.I")
  field(LNK2, "XCOR:DOG:178:IACT.HIGH")
  field(DOL3, "XCOR:DOG:178:IACTLIMITS.J")
  field(LNK3, "XCOR:DOG:178:IACT.LOW")
  field(DOL4, "XCOR:DOG:178:IACTLIMITS.K")
  field(LNK4, "XCOR:DOG:178:IACT.HIHI")
  field(DOL5, "XCOR:DOG:178:IACTLIMITS.L")
  field(LNK5, "XCOR:DOG:178:IACT.LOLO")
  field(DOL6, "XCOR:DOG:178:BLIMITS")
  field(LNK6, "XCOR:DOG:178:IMONLIMITS.F PP")
  field(DOL7, "XCOR:DOG:178:IMONLIMITS.I")
  field(LNK7, "XCOR:DOG:178:IMON.HIGH")
  field(DOL8, "XCOR:DOG:178:IMONLIMITS.J")
  field(LNK8, "XCOR:DOG:178:IMON.LOW")
  field(DOL9, "XCOR:DOG:178:IMONLIMITS.K")
  field(LNK9, "XCOR:DOG:178:IMON.HIHI")
  field(DOLA, "XCOR:DOG:178:IMONLIMITS.L")
  field(LNKA, "XCOR:DOG:178:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "XCOR:DOG:178:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "XCOR:DOG:178:TRIMBTOL")
  field(INPE, "XCOR:DOG:178:CHCKBTOL")
  field(INPF, "XCOR:DOG:178:BDELTAS.K")
  field(INPG, "XCOR:DOG:178:BDELTAS.L")
  field(INPH, "XCOR:DOG:178:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "XCOR:DOG:178:STDZITOLR")
  field(INPC, "XCOR:DOG:178:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:208:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "XCOR:DOG:178:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:208:RESET PP
#
record(bo, "XCOR:DOG:178:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:208:RESET PP")
}

record(bo, "XCOR:DOG:178:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:208:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "XCOR:DOG:178:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "XCOR:DOG:178:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:208:IRAMPRATE PP")
  field(FLNK, "XCOR:DOG:178:STDZDLY")
}


record(ao, "XCOR:DOG:178:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:208:ISETPT PP")
  field(DOL, "XCOR:DOG:178:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "XCOR:DOG:178:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:208:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:DOG:178:BMON")
}

record(ao, "XCOR:DOG:178:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:208:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "XCOR:DOG:178:IRIPLOK")
}

record(sub, "XCOR:DOG:178:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "XCOR:DOG:178:IRIPL.VAL")
  field(INPB, "XCOR:DOG:178:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:DOG:178:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:DOG:178:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "XCOR:DOG:178:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:208:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "XCOR:DOG:178:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:208:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "XCOR:DOG:178:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:DOG:178:IACTPREVOK")
  field(LNK2, "XCOR:DOG:178:IDIFF")
  field(LNK3, "XCOR:DOG:178:IADIFF")
  field(LNK4, "XCOR:DOG:178:IRATIO")
  field(LNK5, "XCOR:DOG:178:IDIRECT")
  field(LNK6, "XCOR:DOG:178:IACTPOL_CHECK")
}

record(calc, "XCOR:DOG:178:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:DOG:178:IDES")
  field(INPB, "XCOR:DOG:178:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(calc, "XCOR:DOG:178:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "XCOR:DOG:178:IDIFF")
  field(PREC, "9")
}

record(calc, "XCOR:DOG:178:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:DOG:178:IDIFF")
  field(INPB, "XCOR:DOG:178:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "XCOR:DOG:178:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "XCOR:DOG:178:IMIN")
  field(INPB,   "XCOR:DOG:178:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "XCOR:DOG:178:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "XCOR:DOG:178:IACT")
  field(INPB, "XCOR:DOG:178:IDES")
  field(INPC, "XCOR:DOG:178:ISETPT")
  field(INPD, "XCOR:DOG:178:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "XCOR:DOG:178:IADJUST PP")
}

record(bo, "XCOR:DOG:178:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "XCOR:DOG:178:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "XCOR:DOG:178:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "XCOR:DOG:178:IACT")
  field(FLNK, "XCOR:DOG:178:IACTPOL")
}
record(bo, "XCOR:DOG:178:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:DOG:178:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"XCOR:DOG:178:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:DOG:178:IDELTAS and the\n  XCOR:DOG:178:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"XCOR:DOG:178:IACT: \n  Get copy of XCOR:DOG:178:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"XCOR:DOG:178:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"XCOR:DOG:178:IDES:\n  Contains raw value calculated by \nXCOR:DOG:178:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nXCOR:DOG:178:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"XCOR:DOG:178:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  XCOR:DOG:178:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               XCOR:DOG:178:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"XCOR:DOG:178:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by XCOR:DOG:178:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, XCOR:DOG:178:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  XCOR:DOG:178:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "XCOR:DOG:178:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:178:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:DOG:178:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:DOG:178:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:DOG:178:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "XCOR:DOG:178:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "XCOR:DOG:178:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "XCOR:DOG:178:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "XCOR:DOG:178:TRIMTYPE.RVAL")
  field(INPB,   "XCOR:DOG:178:CONFIG.RVAL")
  field(OUT,    "XCOR:DOG:178:TRIMMAXNUM PP")
}
record(longout, "XCOR:DOG:178:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "XCOR:DOG:178:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "XCOR:DOG:178:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "XCOR:DOG:178:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "XCOR:DOG:178:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "XCOR:DOG:178:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "XCOR:DOG:178:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "XCOR:DOG:178:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "XCOR:DOG:178:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "XCOR:DOG:178:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "XCOR:DOG:178:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "XCOR:DOG:178:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "XCOR:DOG:178:IMOVE")
 field(INPB, "XCOR:DOG:178:IACT")
 field(INPC, "XCOR:DOG:178:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "XCOR:DOG:178:TRIMDLYPCT")
 field(INPF, "XCOR:DOG:178:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "XCOR:DOG:178:RAMPTIME_LEFT PP")
}

record(longout, "XCOR:DOG:178:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "XCOR:DOG:178:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "XCOR:DOG:178:RAMPDONE_CALC")
}

record(calc, "XCOR:DOG:178:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "XCOR:DOG:178:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "XCOR:DOG:178:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "XCOR:DOG:178:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:DOG:178:RAMPTIME_LEFT")
 field(OUT,  "XCOR:DOG:178:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "XCOR:DOG:178:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:DOG:178:RAMPTIME_LEFT NMS")
 field(OUT,  "XCOR:DOG:178:RAMPDONE PP")
}

record(bo, "XCOR:DOG:178:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "XCOR:DOG:178:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "XCOR:DOG:178:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "XCOR:DOG:178:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:178:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "XCOR:DOG:178:DEBUG.PROC PP")
  field(LNK2, "XCOR:DOG:178:STDZCYCLENUM.PROC PP")
  field(LNK3, "XCOR:DOG:178:STDZDISABLE.PROC PP")
  field(LNK4, "XCOR:DOG:178:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "XCOR:DOG:178:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "XCOR:DOG:178:STDZIMIN NPP NMS")
  field(INPB, "XCOR:DOG:178:STDZIMAX NPP NMS")
  field(INPC, "XCOR:DOG:178:STDZIFINAL NPP NMS")
  field(INPD, "XCOR:DOG:178:STDZCYCLENUM NPP NMS")
  field(INPE, "XCOR:DOG:178:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "XCOR:DOG:178:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "XCOR:DOG:178:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "XCOR:DOG:178:STDZWF PP")
  field(OUTB, "XCOR:DOG:178:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "XCOR:DOG:178:STDZWF")
}

record(mbbo, "XCOR:DOG:178:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "XCOR:DOG:178:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "XCOR:DOG:178:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "XCOR:DOG:178:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "XCOR:DOG:178:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "XCOR:DOG:178:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "XCOR:DOG:178:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:DOG:178:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:DOG:178:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "XCOR:DOG:178:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:178:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "XCOR:DOG:178:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "XCOR:DOG:178:STDZIMIN")
}

record(ao, "XCOR:DOG:178:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "XCOR:DOG:178:STDZIMAX")
}

record(ao, "XCOR:DOG:178:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:178:STDZIFINAL")
}

record(ao, "XCOR:DOG:178:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "XCOR:DOG:178:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "XCOR:DOG:178:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "XCOR:DOG:178:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "XCOR:DOG:178:STDZIMIN CP NMS")
  field(INPB, "XCOR:DOG:178:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "XCOR:DOG:178:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "XCOR:DOG:178:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "XCOR:DOG:178:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "XCOR:DOG:178:STDZIMIN CP NMS")
  field(INPB, "XCOR:DOG:178:STDZIMAX CP NMS")
  field(INPC, "XCOR:DOG:178:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:178:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "XCOR:DOG:178:TRIMDLYPCT CP MS")
  field(INPB, "XCOR:DOG:178:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "XCOR:DOG:178:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "XCOR:DOG:178:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:178:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "XCOR:DOG:178:IDES.HOPR")
  field(INPB, "XCOR:DOG:178:STDZMINIPCT CPP NMS")
  field(INPC, "XCOR:DOG:178:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "XCOR:DOG:178:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "XCOR:DOG:178:IDES.HOPR")
  field(INPB, "XCOR:DOG:178:IDES.LOPR")
  field(INPC, "XCOR:DOG:178:STDZDIRECT.RVAL")
  field(INPD, "XCOR:DOG:178:STDZMINIDELTA")
  field(INPE, "XCOR:DOG:178:IDES")
  field(PREC, "5")
  field(FLNK, "XCOR:DOG:178:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "XCOR:DOG:178:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "XCOR:DOG:178:IDES.HOPR")
  field(INPB, "XCOR:DOG:178:IDES.LOPR")
  field(INPC, "XCOR:DOG:178:STDZDIRECT.RVAL")
  field(INPD, "XCOR:DOG:178:STDZMINIDELTA")
  field(INPE, "XCOR:DOG:178:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "XCOR:DOG:178:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "XCOR:DOG:178:IADJUST.RVAL")
  field(INPB, "XCOR:DOG:178:STDZDIRECT.RVAL")
  field(INPC, "XCOR:DOG:178:STDZOK.RVAL")
  field(INPD, "XCOR:DOG:178:STDZDISABLE.RVAL")
  field(INPE, "XCOR:DOG:178:STATE.RVAL CPP NMS")
  field(INPF, "XCOR:DOG:178:ICTRL.RVAL")
  field(INPG, "XCOR:DOG:178:STATE.SEVR")
  field(INPH, "XCOR:DOG:178:BDELTAS.M")
  field(INPI, "XCOR:DOG:178:IACT.SEVR")
  field(OUT,  "XCOR:DOG:178:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "XCOR:DOG:178:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "XCOR:DOG:178:STDZLOSTTOD.PROC")
  field(LNK2, "XCOR:DOG:178:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "XCOR:DOG:178:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:178:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:DOG:178:IACT CP")
  field(INPB, "XCOR:DOG:178:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "XCOR:DOG:178:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "XCOR:DOG:178:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:178:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:DOG:178:STDZIACTMAX")
  field(INPB, "XCOR:DOG:178:IACT")
  field(INPC, "XCOR:DOG:178:IDELTAS.I")
  field(OUT,  "XCOR:DOG:178:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "XCOR:DOG:178:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "XCOR:DOG:178:STDZOK.RVAL CP")
  field(INPB, "XCOR:DOG:178:STDZDISABLE.RVAL CP")
  field(INPC, "XCOR:DOG:178:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "XCOR:DOG:178:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "XCOR:DOG:178:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "XCOR:DOG:178:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "XCOR:DOG:178:CALBOK")
  field(INPB, "XCOR:DOG:178:CALBDISABLE")
  field(INPC, "XCOR:DOG:178:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "XCOR:DOG:178:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "XCOR:DOG:178:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "XCOR:DOG:178:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "XCOR:DOG:178:CALBSLOPE")
  field(DOL3, "XCOR:DOG:178:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "XCOR:DOG:178:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:178:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "XCOR:DOG:178:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "XCOR:DOG:178:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "XCOR:DOG:178:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "XCOR:DOG:178:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "XCOR:DOG:178:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:178:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "XCOR:DOG:178:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:178:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "XCOR:DOG:178:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "XCOR:DOG:178:IACT")
  field(INPD, "XCOR:DOG:178:DACSLOPE")
  field(INPE, "XCOR:DOG:178:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "XCOR:DOG:178:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "XCOR:DOG:178:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "2")
  field(HOPR, "2")
  field(DRVL, "-2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "XCOR:DOG:178:CALBIMAX")
}

record(ao, "XCOR:DOG:178:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "2")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:178:CALBSTEPNUM")
}

record(ao, "XCOR:DOG:178:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL, "0")
}

record(longout, "XCOR:DOG:178:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:DOG:178:CALBIDELTA")
}

record(calc, "XCOR:DOG:178:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "XCOR:DOG:178:CALBIMAX")
  field(INPB, "XCOR:DOG:178:CALBIMIN")
  field(INPC, "XCOR:DOG:178:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "XCOR:DOG:178:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:208:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:208:IACT.HOPR")
  field(INPC, "XCOR:DOG:178:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "XCOR:DOG:178:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:DOG:178:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:178:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:178:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:178:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "XCOR:DOG:178:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:178:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:178:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:178:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "XCOR:DOG:178:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:178:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:178:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:178:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:DOG:178:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:178:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:178:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "XCOR:DOG:178:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:178:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "XCOR:DOG:178:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "XCOR:DOG:178:CALBSTEPNUM")
  field(INPB, "XCOR:DOG:178:CALBIACTWF")
  field(INPC, "XCOR:DOG:178:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "XCOR:DOG:178:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "XCOR:DOG:178:STDZITOL")

  field(INPH, "XCOR:DOG:178:DACSLOPE")
  field(INPI, "XCOR:DOG:178:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "XCOR:DOG:178:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "XCOR:DOG:178:CALBSTEPNUM")
  field(INPB, "XCOR:DOG:178:CALBIACTWF")
  field(INPC, "XCOR:DOG:178:DACWF")
  field(INPF, "XCOR:DOG:178:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe XCOR:DOG:178CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "XCOR:DOG:178:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "XCOR:DOG:178:DEGAUSIMIN.PROC PP")
  field(OUTB, "XCOR:DOG:178:DEGAUSIMAX.PROC PP")
  field(OUTC, "XCOR:DOG:178:DEGAUSTYPE.PROC PP")
  field(OUTD, "XCOR:DOG:178:DEGAUSSTEP.PROC PP")
  field(OUTE, "XCOR:DOG:178:MADNAME.PROC PP")
  field(OUTF, "XCOR:DOG:178:PSTYPE.PROC PP")
  field(OUTG, "XCOR:DOG:178:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "XCOR:DOG:178:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:DOG:178:DEGAUSIMIN NPP NMS")
  field(INPB, "XCOR:DOG:178:DEGAUSIMAX NPP NMS")
  field(INPC, "XCOR:DOG:178:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "XCOR:DOG:178:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "XCOR:DOG:178:PSTYPE NPP NMS")
  field(INPG, "XCOR:DOG:178:DEBUG.RVAL NPP NMS")
  field(INPH, "XCOR:DOG:178:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "XCOR:DOG:178:DEGAUSWF PP")
  field(OUTB, "XCOR:DOG:178:DEGAUSMSG PP")
  field(OUTC, "XCOR:DOG:178:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "XCOR:DOG:178:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"XCOR:DOG:178:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "XCOR:DOG:178:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "XCOR:DOG:178:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "XCOR:DOG:178:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "XCOR:DOG:178:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "XCOR:DOG:178:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "-2")
}
record(ao, "XCOR:DOG:178:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"XCOR:DOG:178:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "XCOR:DOG:178:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"XCOR:DOG:178:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "XCOR:DOG:178:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "XCOR:DOG:178:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "XCOR:DOG:178:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "XCOR:DOG:178:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:DOG:178:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:178:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:DOG:178:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:DOG:178:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "XCOR:DOG:178:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "XCOR:DOG:178:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "XCOR:DOG:178:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "XCOR:DOG:178:DEGAUS_IMAX")
  field(INPB, "XCOR:DOG:178:ISETPT")
  field(INPC, "XCOR:DOG:178:DEGAUSTYPE.RVAL")
  field(OUT,  "XCOR:DOG:178:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "XCOR:DOG:178:DEGAUS_IMAX_UPDATE")
}
record(seq, "XCOR:DOG:178:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "XCOR:DOG:178:ISETPT")
  field(LNK1, "XCOR:DOG:178:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "XCOR:DOG:178:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:178:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "XCOR:DOG:178:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "XCOR:DOG:178:DEGAUS_IMAX")
  field(FLNK, "XCOR:DOG:178:DEGAUS_IMAXPOL")
}
record(bo, "XCOR:DOG:178:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:DOG:178:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "XCOR:DOG:178:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "XCOR:DOG:178:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "XCOR:DOG:178:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "XCOR:DOG:178:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "XCOR:DOG:178:IACT")
  field(INPB, "XCOR:DOG:178:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "XCOR:DOG:178:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "XCOR:DOG:178:IACTPOL")
}
record(bo, "XCOR:DOG:178:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"XCOR:DOG:178:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "XCOR:DOG:178:DEGAUSENABLE CP")
  field(INPB, "XCOR:DOG:178:DEGAUSOK")
  field(INPC, "XCOR:DOG:178:STATE CP")
  field(INPD, "XCOR:DOG:178:STATE.SEVR")
  field(OUT,  "XCOR:DOG:178:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "XCOR:DOG:178:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "XCOR:DOG:178:DEGAUS_STATE_CHECK")
  field(LNK1, "XCOR:DOG:178:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "XCOR:DOG:178:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "XCOR:DOG:178:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "XCOR:DOG:178:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "XCOR:DOG:178:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "XCOR:DOG:178:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:DOG:178:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "XCOR:DOG:178:STATMSG.FRSV")
  field(LNK4, "XCOR:DOG:178:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:DOG:178:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:178:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:DOG:178:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "XCOR:DOG:178:STATMSG.FRSV")
  field(LNK4, "XCOR:DOG:178:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:DOG:178:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "XCOR:DOG:178:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "XCOR:DOG:178:STATMSG.FRSV")
  field(LNK3, "XCOR:DOG:178:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "XCOR:DOG:178:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:178:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "XCOR:DOG:178:STATMSG.FRSV PP")
  field(LNK3, "XCOR:DOG:178:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "XCOR:DOG:178:FUNC") {
  field(DESC, "XCOR:DOG:178 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "XCOR:DOG:178:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:DOG:178:CTRL") {
  field(DESC, "XCOR:DOG:178 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "XCOR:DOG:178:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "XCOR:DOG:178:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "XCOR:DOG:178:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "XCOR:DOG:178:BUSY") {
  field(DESC, "XCOR:DOG:178 Ctrl Done")
  field(DOL, "XCOR:DOG:178:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:178:SELECT")
}

record(bo, "XCOR:DOG:178:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "XCOR:DOG:178:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:DOG:178:CTRLSTATE") {
  field(DESC, "XCOR:DOG:178 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("XCOR:DOG:178:CTRL",20,20,0,0,"XCOR:DOG:178:CTRL")
#! Field("XCOR:DOG:178:CTRL.OUT",16777215,1,"XCOR:DOG:178:CTRL.OUT")
#! Link("XCOR:DOG:178:CTRL.OUT","XCOR:DOG:178:SELECTEN.A")
#! Field("XCOR:DOG:178:CTRL.VAL",16777215,1,"XCOR:DOG:178:CTRL.VAL")
#! Record("XCOR:DOG:178:SELECTEN",321,381,0,0,"XCOR:DOG:178:SELECTEN")
#! Field("XCOR:DOG:178:SELECTEN.A",16777215,0,"XCOR:DOG:178:SELECTEN.A")
#! Field("XCOR:DOG:178:SELECTEN.FLNK",16777215,1,"XCOR:DOG:178:SELECTEN.FLNK")
#! Link("XCOR:DOG:178:SELECTEN.FLNK","XCOR:DOG:178:BUSY")
#! Field("XCOR:DOG:178:SELECTEN.VAL",16777215,1,"XCOR:DOG:178:SELECTEN.VAL")
#! Record("XCOR:DOG:178:BUSY",623,274,0,0,"XCOR:DOG:178:BUSY")
#! Field("XCOR:DOG:178:BUSY.DOL",16777215,0,"XCOR:DOG:178:BUSY.DOL")
#! Link("XCOR:DOG:178:BUSY.DOL","XCOR:DOG:178:SELECTEN.VAL")
#! Field("XCOR:DOG:178:BUSY.FLNK",16777215,1,"XCOR:DOG:178:BUSY.FLNK")
#! Link("XCOR:DOG:178:BUSY.FLNK","XCOR:DOG:178:SELECT")
#! Record("XCOR:DOG:178:SELECT",669,508,0,1,"XCOR:DOG:178:SELECT")
#! Record("XCOR:DOG:178:FUNC",940,120,0,0,"XCOR:DOG:178:FUNC")
#! Field("XCOR:DOG:178:FUNC.OUT",16777215,0,"XCOR:DOG:178:FUNC.OUT")
#! Link("XCOR:DOG:178:FUNC.OUT","XCOR:DOG:178:CTRL.VAL")
#! Record("XCOR:DOG:178:ABORT",193,41,0,0,"XCOR:DOG:178:ABORT")
#! Record("XCOR:DOG:178:CTRLSTATE",369,34,0,0,"XCOR:DOG:178:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"XCOR:DOG:178:SELECT is used for Multi-device selection.\nIt is enabled when associated XCOR:DOG:178:CTRL is \"0\" (DONE).\nIt is disabled when associated XCOR:DOG:178:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"XCOR:DOG:178:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "XCOR:DOG:178:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "XCOR:DOG:178:BCTRL.SEVR")
  field(OUT,  "XCOR:DOG:178:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "XCOR:DOG:178:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:DOG:178:BACT")
  field(INPB, "XCOR:DOG:178:POLYCOEF")
  field(INPC, "XCOR:DOG:178:POLYCOEF.A")
  field(INPD, "XCOR:DOG:178:POLYCOEF.B")
  field(INPE, "XCOR:DOG:178:IACT MS")
  field(INPF, "XCOR:DOG:178:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
  field(FLNK, "XCOR:DOG:178:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "XCOR:DOG:178:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:DOG:178:BDES")
  field(INPB, "XCOR:DOG:178:TRIMBTOL")
  field(INPC, "XCOR:DOG:178:TRIMBTOLR")
  field(INPD, "XCOR:DOG:178:CHCKBTOL")
  field(INPE, "XCOR:DOG:178:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "XCOR:DOG:178:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "XCOR:DOG:178:MPSBTOL")
  field(INPQ, "XCOR:DOG:178:MPSBTOLR")
  field(FLNK, "XCOR:DOG:178:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "XCOR:DOG:178:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "XCOR:DOG:178:BDES")
  field(INPB, "XCOR:DOG:178:BDELTAS.I")
  field(INPG, "XCOR:DOG:178:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "XCOR:DOG:178:BCON.HIGH")
  field(OUTB, "XCOR:DOG:178:BCON.LOW")
  field(OUTC, "XCOR:DOG:178:BCON.HIHI")
  field(OUTD, "XCOR:DOG:178:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:178:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "XCOR:DOG:178:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:DOG:178:BDIFF")
  field(LNK2, "XCOR:DOG:178:BADIFF")
  field(LNK3, "XCOR:DOG:178:BRATIO")
  field(LNK4, "XCOR:DOG:178:MPSLIMITS")
  field(LNK5, "XCOR:DOG:178:I2BSTATUS")
  field(LNK6, "XCOR:DOG:178:IACTFO.PROC")
}

record(calc, "XCOR:DOG:178:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:DOG:178:BDES")
  field(INPB, "XCOR:DOG:178:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "XCOR:DOG:178:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "XCOR:DOG:178:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "XCOR:DOG:178:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:DOG:178:BDIFF")
  field(INPB, "XCOR:DOG:178:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "XCOR:DOG:178:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "XCOR:DOG:178:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "XCOR:DOG:178:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:DOG:178:BMON")
  field(INPB, "XCOR:DOG:178:POLYCOEF")
  field(INPC, "XCOR:DOG:178:POLYCOEF.A")
  field(INPD, "XCOR:DOG:178:POLYCOEF.B")
  field(INPE, "XCOR:DOG:178:IMON MS")
  field(INPF, "XCOR:DOG:178:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:208:BDES CP
record(ao,  "XCOR:DOG:178:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.02098636")
   field(DRVL, "-0.02098636")
   field(HOPR, "0.02098636")
   field(LOPR, "-0.02098636")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "XCOR:DOG:178:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "XCOR:DOG:178:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:178:POLYCOEF")
  field(INPC, "XCOR:DOG:178:POLYCOEF.A")
  field(INPD, "XCOR:DOG:178:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "XCOR:DOG:178:BDES.DRVH")
  field(INPF, "XCOR:DOG:178:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:178:IDES")
}
record(sub, "XCOR:DOG:178:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:178:POLYCOEF")
  field(INPC, "XCOR:DOG:178:POLYCOEF.A")
  field(INPD, "XCOR:DOG:178:POLYCOEF.B")
  field(INPE, "XCOR:DOG:178:BDES.DRVH")
  field(INPF, "XCOR:DOG:178:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "XCOR:DOG:178:INOM")
}

record(sub, "XCOR:DOG:178:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:178:BDES.VAL")
  field(INPB, "XCOR:DOG:178:BDES.DRVH")
  field(INPC, "XCOR:DOG:178:BDES.DRVL")
  field(INPD, "XCOR:DOG:178:BDELTAS.I")
  field(INPE, "XCOR:DOG:178:BDELTAS.J")
  field(INPG, "XCOR:DOG:178:STATE")
  field(INPH, "XCOR:DOG:178:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:DOG:178:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:178:BDES.VAL")
  field(INPB, "XCOR:DOG:178:BDES.DRVH")
  field(INPC, "XCOR:DOG:178:BDES.DRVL")
  field(INPD, "XCOR:DOG:178:BDELTAS.K")
  field(INPE, "XCOR:DOG:178:BDELTAS.L")
  field(INPG, "XCOR:DOG:178:STATE")
  field(INPH, "XCOR:DOG:178:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:DOG:178:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "XCOR:DOG:178:BLIMITS")
  field(LNK1, "XCOR:DOG:178:BACTLIMITS.F PP")
  field(DOL2, "XCOR:DOG:178:BACTLIMITS.I")
  field(LNK2, "XCOR:DOG:178:BACT.HIGH")
  field(DOL3, "XCOR:DOG:178:BACTLIMITS.J")
  field(LNK3, "XCOR:DOG:178:BACT.LOW")
  field(DOL4, "XCOR:DOG:178:BACTLIMITS.K")
  field(LNK4, "XCOR:DOG:178:BACT.HIHI")
  field(DOL5, "XCOR:DOG:178:BACTLIMITS.L")
  field(LNK5, "XCOR:DOG:178:BACT.LOLO")
  field(DOL6, "XCOR:DOG:178:BLIMITS")
  field(LNK6, "XCOR:DOG:178:BMONLIMITS.F PP")
  field(DOL7, "XCOR:DOG:178:BMONLIMITS.I")
  field(LNK7, "XCOR:DOG:178:BMON.HIGH")
  field(DOL8, "XCOR:DOG:178:BMONLIMITS.J")
  field(LNK8, "XCOR:DOG:178:BMON.LOW")
  field(DOL9, "XCOR:DOG:178:BMONLIMITS.K")
  field(LNK9, "XCOR:DOG:178:BMON.HIHI")
  field(DOLA, "XCOR:DOG:178:BMONLIMITS.L")
  field(LNKA, "XCOR:DOG:178:BMON.LOLO")
  field(FLNK, "XCOR:DOG:178:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "XCOR:DOG:178:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "XCOR:DOG:178:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "XCOR:DOG:178:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:178:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "XCOR:DOG:178:BCTRL.VAL")
  field(LNK2, "XCOR:DOG:178:BDES PP")

  field(DOL3, "1")
  field(LNK3, "XCOR:DOG:178:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "XCOR:DOG:178:CHECKSTDZLOST.PROC PP")

  field(DOL5, "XCOR:DOG:178:BCTRL.VAL")
  field(LNK5, "XCOR:DOG:178:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "XCOR:DOG:178:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "XCOR:DOG:178:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:178:POLYCOEF")
  field(INPC, "XCOR:DOG:178:POLYCOEF.A")
  field(INPD, "XCOR:DOG:178:POLYCOEF.B")
  field(INPE, "XCOR:DOG:178:BDES.DRVH")
  field(INPF, "XCOR:DOG:178:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:178:ISETPT")
}

record(ao, "XCOR:DOG:178:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "XCOR:DOG:178:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "XCDOG5")
}

record(ai, "XCOR:DOG:178:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "710.337429")
}

record(ao, "XCOR:DOG:178:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(FLNK, "XCOR:DOG:178:BSTEP")
}

record(ao, "XCOR:DOG:178:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(FLNK, "XCOR:DOG:178:BSTEP")
}

record(ao, "XCOR:DOG:178:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by XCOR:DOG:178:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "XCOR:DOG:178:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "XCOR:DOG:178:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "XCOR:DOG:178:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:178:POLYCOEF")
  field(INPC, "XCOR:DOG:178:POLYCOEF.A")
  field(INPD, "XCOR:DOG:178:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "XCOR:DOG:178:BCON.DRVH")
  field(INPF, "XCOR:DOG:178:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:178:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "XCOR:DOG:178:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "XCOR:DOG:178:BMAX")
  field(INPB, "XCOR:DOG:178:BMIN")
  field(INPC, "XCOR:DOG:178:BMIN.SEVR")
  field(INPD, "XCOR:DOG:178:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"XCOR:DOG:178:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "XCOR:DOG:178:ONLINE CP")
  field(OUT,  "XCOR:DOG:178:BCTRLDISABLEFOUT PP")
}

record(fanout, "XCOR:DOG:178:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "XCOR:DOG:178:BCTRLDISABLECALC")
  field(LNK1, "XCOR:DOG:178:BCTRLDISABLE")
  field(LNK2, "XCOR:DOG:178:BCTRLENABLE")
}

record(stringout, "XCOR:DOG:178:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:DOG:178:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "XCOR:DOG:178:BCTRLDISV_UPDATE")
}

record(stringout, "XCOR:DOG:178:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:DOG:178:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "XCOR:DOG:178:BCTRLDISV_UPDATE")
}

record(calcout, "XCOR:DOG:178:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "XCOR:DOG:178:ONLINE")
  field(OUT,  "XCOR:DOG:178:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"XCOR:DOG:178:BACT and MON\n  are processed via links from \n  XCOR:DOG:178:IACT (device raw value readback 1)\n  and\n  XCOR:DOG:178:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from XCOR:DOG:178:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = XCOR:DOG:178:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"XCOR:DOG:178:BDES\n  is processed when set by CA users or \n  XCOR:DOG:178:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"XCOR:DOG:178:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  XCOR:DOG:178:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (XCOR:DOG:178:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"XCOR:DOG:178:B*LIMITS and XCOR:DOG:178:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:DOG:178:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"XCOR:DOG:178:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"XCOR:DOG:178:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "XCOR:DOG:178:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:178:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "XCOR:DOG:178:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "XCOR:DOG:178:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:178:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:178:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:178:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "XCOR:DOG:178:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "XCOR:DOG:178:MPSLIMITS.E PP")
}

record(aSub, "XCOR:DOG:178:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "XCOR:DOG:178:MPS.RVAL")
  field(INPB, "XCOR:DOG:178:BADIFF")
  field(INPC, "XCOR:DOG:178:BDELTAS.N")
  field(INPD, "XCOR:DOG:178:BACT")
  field(INPE, "XCOR:DOG:178:MPSBITMASK.RVAL")
  field(INPF, "XCOR:DOG:178:MPSBLLIM")
  field(INPG, "XCOR:DOG:178:MPSBMIN")
  field(INPH, "XCOR:DOG:178:MPSBMAX")
  field(INPI, "XCOR:DOG:178:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "XCOR:DOG:178:INTOL.RVAL PP")
  field(OUTB, "XCOR:DOG:178:INTOL_BMIN.RVAL PP")
  field(OUTC, "XCOR:DOG:178:INTOL_BRANGE.RVAL PP")
  field(OUTD, "XCOR:DOG:178:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "XCOR:DOG:178:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:178:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:178:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:178:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:178:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:178:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:178:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:178:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "XCOR:DOG:178:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "XCOR:DOG:178:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:DOG:178:CHCKBTOL")
  field(INPB, "XCOR:DOG:178:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "XCOR:DOG:178:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "XCOR:DOG:178:CHCKBTOL")
  field(FLNK, "XCOR:DOG:178:CHCKITOL")
}

record(calc, "XCOR:DOG:178:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "XCOR:DOG:178:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "XCOR:DOG:178:BDES.HOPR")
  field(INPB, "XCOR:DOG:178:STABILITY")
  field(INPC, "XCOR:DOG:178:BDES.LOPR")
}

record(longout, "XCOR:DOG:178:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "XCOR:DOG:178:CHCKBTOL")
}

record(calc, "XCOR:DOG:178:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:DOG:178:POLYCOEF.B")
  field(INPB, "XCOR:DOG:178:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "XCOR:DOG:178:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "XCOR:DOG:178:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "XCOR:DOG:178:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "XCOR:DOG:178:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "XCOR:DOG:178:PAUGO")  
}

record(fanout, "XCOR:DOG:178:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "XCOR:DOG:178:PAUSTOP")
  field(LNK2, "XCOR:DOG:178:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "XCOR:DOG:178:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "XCOR:DOG:178:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:208:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:208:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "XCOR:DOG:178:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "XCOR:DOG:178:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:208:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:208:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "XCOR:DOG:178:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:208:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:DOG:178:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "XCOR:DOG:178:PSTYPE.RVAL")
  field(INPC, "XCOR:DOG:178:TURNEDOFF.RVAL")
  field(INPD, "XCOR:DOG:178:CONFIG.RVAL")
  field(INPE, "XCOR:DOG:178:PSCATEGORY.RVAL")
  field(INPF, "XCOR:DOG:178:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "XCOR:DOG:178:AUTOCTRL.RVAL")
  field(INPJ, "XCOR:DOG:178:OUTOFSERVICE.RVAL")
  field(INPL, "XCOR:DOG:178:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "XCOR:DOG:178:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "XCOR:DOG:178:PAU")
  field(INPP, "XCOR:DOG:178:CALBDISABLE.RVAL")
  field(INPQ, "XCOR:DOG:178:PTRBDISABLE.RVAL")
  field(INPR, "XCOR:DOG:178:TRIMDISABLE.RVAL")
  field(INPS, "XCOR:DOG:178:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "XCOR:DOG:178:FBCK")
  field(INPU, "XCOR:DOG:178:TRIMTYPE.RVAL")
  field(INPV, "XCOR:DOG:178:STDZDIRECT.RVAL")
  field(INPW, "XCOR:DOG:178:DEGAUSENABLE.RVAL")
  field(FLNK, "XCOR:DOG:178:HSTA")
}

record(longin, "XCOR:DOG:178:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "XCOR:DOG:178:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "XCOR:DOG:178:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "XCOR:DOG:178:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "XCOR:DOG:178:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:178:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:178:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:178:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by XCOR:DOG:178:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses XCOR:DOG:178:FBCK.
# This PV should be replaced by XCOR:DOG:178:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "XCOR:DOG:178:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "XCOR:DOG:178:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:DOG:178:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:178:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"XCOR:DOG:178:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "XCOR:DOG:178:OUTOFSERVICE NPP NMS")
  field(OUT,  "XCOR:DOG:178:ONLINE PP")
}
record(bo, "XCOR:DOG:178:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "XCOR:DOG:178:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:DOG:178:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "XCOR:DOG:178:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "XCOR:DOG:178:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "XCOR:DOG:178:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "XCOR:DOG:178:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "XCOR:DOG:178:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "XCOR:DOG:178:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:178:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:178:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:178:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "XCOR:DOG:178:TRIMTYPE")
}

record(stringout, "XCOR:DOG:178:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "XCOR:DOG:178:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "XCOR:DOG:178:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "XCOR:DOG:178:STATE.RVAL")
  field(INPB, "XCOR:DOG:178:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:DOG:178:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:DOG:178:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "XCOR:DOG:178:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "XCOR:DOG:178:STATE.RVAL")
  field(INPB, "XCOR:DOG:178:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:DOG:178:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:DOG:178:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "XCOR:DOG:178:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "XCOR:DOG:178:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "XCOR:DOG:178:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "XCOR:DOG:178:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "XCOR:DOG:178:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"XCOR:DOG:178:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("XCOR:DOG:178:TURNEDOFF",3140,1907,0,1,"XCOR:DOG:178:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:DOG:178:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "XCOR:DOG:178:BACT.STAT")
  field(INPB, "XCOR:DOG:178:BDES.STAT")
  field(INPC, "XCOR:DOG:178:IRIPL.STAT")
  field(INPD, "MCOR:EXT:208:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:208:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "XCOR:DOG:178:BACT.SEVR")
  field(INPH, "XCOR:DOG:178:BDES.SEVR")
  field(INPI, "XCOR:DOG:178:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:208:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:208:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "XCOR:DOG:178:STATE.RVAL")
  field(INPN, "XCOR:DOG:178:STDZOK")
  field(INPO, "XCOR:DOG:178:CALBOK")
  field(INPP, "XCOR:DOG:178:OUTOFSERVICE.RVAL")
  field(INPQ, "XCOR:DOG:178:CONFIG.RVAL")
  field(INPR, "XCOR:DOG:178:HSTA")
  field(INPS, "XCOR:DOG:178:CTRL.RVAL")
  field(INPT, "XCOR:DOG:178:DEGAUSOK") 
  field(INPV, "XCOR:DOG:178:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:178:STAT")
}

record(longout, "XCOR:DOG:178:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "XCOR:DOG:178:STATCTRLSUB")
  field(DOL, "XCOR:DOG:178:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "XCOR:DOG:178:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "XCOR:DOG:178:STAT")
  field(INPB, "XCOR:DOG:178:HSTA")
  field(INPD, "XCOR:DOG:178:ONOFFCTRL.RVAL")
  field(FLNK, "XCOR:DOG:178:STATMSG")
}

record(mbbo, "XCOR:DOG:178:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:DOG:178:UNAVAILGO")
  field(DOL, "XCOR:DOG:178:STATCTRLSUB.W")
}

record(seq, "XCOR:DOG:178:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "XCOR:DOG:178:STATSUB.U")
  field(LNK1, "XCOR:DOG:178:UNAVAIL PP")
}

record(stringout, "XCOR:DOG:178:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"XCOR:DOG:178:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - XCOR:DOG:178:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - XCOR:DOG:178:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"XCOR:DOG:178STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - XCOR:DOG:178:STATUS\nC - XCOR:DOG:178:ON\nD - XCOR:DOG:178:STDZOK\nE - XCOR:DOG:178:CALBOK\nF - XCOR:DOG:178:BACTDRIFT (future)\nG -\nH- XCOR:DOG:178:DACSTATUS\nI -XCOR:DOG:178:ADCSTATUS\nJ - XCOR:DOG:178:BACTSTATUS\nK - XCOR:DOG:178:BDESSTATUS\nL - XCOR:DOG:178:RIPLSTATUS\n\nOutput:\nP - XCOR:DOG:178:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "XCOR:DOG:178:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "XCOR:DOG:178:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "XCOR:DOG:178:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "XCOR:DOG:178:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "YCOR:DOG:193:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:209:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:DOG:193:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "YCOR:DOG:193:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:209:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "YCOR:DOG:193:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "2")
  field(LOLO, "-2")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "YCOR:DOG:193:BDELTAS")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "YCOR:DOG:193:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "YCOR:DOG:193:ICTRL PP")
}

# This record is processed by YCOR:DOG:193:ICON")
# Note: we are not setting alarms here.
record(ao, "YCOR:DOG:193:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "YCOR:DOG:193:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:193:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "YCOR:DOG:193:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(ao, "YCOR:DOG:193:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(FLNK, "YCOR:DOG:193:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "YCOR:DOG:193:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "YCOR:DOG:193:ISETPT.OMSL")

  field(DOL2, "YCOR:DOG:193:ICTRL")
  field(LNK2, "YCOR:DOG:193:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "YCOR:DOG:193:ISETPT.OMSL")
}

record(ao, "YCOR:DOG:193:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:193:IMIN")
}

record(ao, "YCOR:DOG:193:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(VAL,  "-2")
  field(FLNK, "YCOR:DOG:193:IRANGE")
}

record(sel, "YCOR:DOG:193:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(NVL,  "YCOR:DOG:193:BACT.SEVR")
  field(INPA, "YCOR:DOG:193:IACT NPP MS")
  field(INPB, "YCOR:DOG:193:IACTPREVOK NPP MS")
  field(INPC, "YCOR:DOG:193:IACTPREVOK NPP MS")
  field(INPD, "YCOR:DOG:193:IACTPREVOK NPP MS")
}

record(sub, "YCOR:DOG:193:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:193:IDES")
  field(INPB, "YCOR:DOG:193:ISETPT.DRVH")
  field(INPC, "YCOR:DOG:193:ISETPT.DRVL")
  field(INPD, "YCOR:DOG:193:IDELTAS.I")
  field(INPE, "YCOR:DOG:193:IDELTAS.J")
  field(INPG, "YCOR:DOG:193:STATE")
  field(INPH, "YCOR:DOG:193:HSTA")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:DOG:193:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:193:IDES")
  field(INPB, "YCOR:DOG:193:ISETPT.DRVH")
  field(INPC, "YCOR:DOG:193:ISETPT.DRVL")
  field(INPD, "YCOR:DOG:193:IDELTAS.K")
  field(INPE, "YCOR:DOG:193:IDELTAS.L")
  field(INPG, "YCOR:DOG:193:STATE")
  field(INPH, "YCOR:DOG:193:HSTA")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:DOG:193:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "YCOR:DOG:193:BLIMITS")
  field(LNK1, "YCOR:DOG:193:IACTLIMITS.F PP")
  field(DOL2, "YCOR:DOG:193:IACTLIMITS.I")
  field(LNK2, "YCOR:DOG:193:IACT.HIGH")
  field(DOL3, "YCOR:DOG:193:IACTLIMITS.J")
  field(LNK3, "YCOR:DOG:193:IACT.LOW")
  field(DOL4, "YCOR:DOG:193:IACTLIMITS.K")
  field(LNK4, "YCOR:DOG:193:IACT.HIHI")
  field(DOL5, "YCOR:DOG:193:IACTLIMITS.L")
  field(LNK5, "YCOR:DOG:193:IACT.LOLO")
  field(DOL6, "YCOR:DOG:193:BLIMITS")
  field(LNK6, "YCOR:DOG:193:IMONLIMITS.F PP")
  field(DOL7, "YCOR:DOG:193:IMONLIMITS.I")
  field(LNK7, "YCOR:DOG:193:IMON.HIGH")
  field(DOL8, "YCOR:DOG:193:IMONLIMITS.J")
  field(LNK8, "YCOR:DOG:193:IMON.LOW")
  field(DOL9, "YCOR:DOG:193:IMONLIMITS.K")
  field(LNK9, "YCOR:DOG:193:IMON.HIHI")
  field(DOLA, "YCOR:DOG:193:IMONLIMITS.L")
  field(LNKA, "YCOR:DOG:193:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "YCOR:DOG:193:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "YCOR:DOG:193:TRIMBTOL")
  field(INPE, "YCOR:DOG:193:CHCKBTOL")
  field(INPF, "YCOR:DOG:193:BDELTAS.K")
  field(INPG, "YCOR:DOG:193:BDELTAS.L")
  field(INPH, "YCOR:DOG:193:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "YCOR:DOG:193:STDZITOLR")
  field(INPC, "YCOR:DOG:193:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:209:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "YCOR:DOG:193:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:209:RESET PP
#
record(bo, "YCOR:DOG:193:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:209:RESET PP")
}

record(bo, "YCOR:DOG:193:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:209:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "YCOR:DOG:193:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "YCOR:DOG:193:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:209:IRAMPRATE PP")
  field(FLNK, "YCOR:DOG:193:STDZDLY")
}


record(ao, "YCOR:DOG:193:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:209:ISETPT PP")
  field(DOL, "YCOR:DOG:193:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "YCOR:DOG:193:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:209:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:DOG:193:BMON")
}

record(ao, "YCOR:DOG:193:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:209:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "YCOR:DOG:193:IRIPLOK")
}

record(sub, "YCOR:DOG:193:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "YCOR:DOG:193:IRIPL.VAL")
  field(INPB, "YCOR:DOG:193:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:DOG:193:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:DOG:193:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "YCOR:DOG:193:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:209:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "YCOR:DOG:193:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:209:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "YCOR:DOG:193:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:DOG:193:IACTPREVOK")
  field(LNK2, "YCOR:DOG:193:IDIFF")
  field(LNK3, "YCOR:DOG:193:IADIFF")
  field(LNK4, "YCOR:DOG:193:IRATIO")
  field(LNK5, "YCOR:DOG:193:IDIRECT")
  field(LNK6, "YCOR:DOG:193:IACTPOL_CHECK")
}

record(calc, "YCOR:DOG:193:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:DOG:193:IDES")
  field(INPB, "YCOR:DOG:193:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(calc, "YCOR:DOG:193:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "YCOR:DOG:193:IDIFF")
  field(PREC, "9")
}

record(calc, "YCOR:DOG:193:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:DOG:193:IDIFF")
  field(INPB, "YCOR:DOG:193:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "YCOR:DOG:193:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "YCOR:DOG:193:IMIN")
  field(INPB,   "YCOR:DOG:193:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "YCOR:DOG:193:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "YCOR:DOG:193:IACT")
  field(INPB, "YCOR:DOG:193:IDES")
  field(INPC, "YCOR:DOG:193:ISETPT")
  field(INPD, "YCOR:DOG:193:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "YCOR:DOG:193:IADJUST PP")
}

record(bo, "YCOR:DOG:193:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "YCOR:DOG:193:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "YCOR:DOG:193:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "YCOR:DOG:193:IACT")
  field(FLNK, "YCOR:DOG:193:IACTPOL")
}
record(bo, "YCOR:DOG:193:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:DOG:193:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"YCOR:DOG:193:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:DOG:193:IDELTAS and the\n  YCOR:DOG:193:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"YCOR:DOG:193:IACT: \n  Get copy of YCOR:DOG:193:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"YCOR:DOG:193:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"YCOR:DOG:193:IDES:\n  Contains raw value calculated by \nYCOR:DOG:193:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nYCOR:DOG:193:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"YCOR:DOG:193:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  YCOR:DOG:193:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               YCOR:DOG:193:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"YCOR:DOG:193:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by YCOR:DOG:193:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, YCOR:DOG:193:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  YCOR:DOG:193:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "YCOR:DOG:193:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:193:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:DOG:193:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:DOG:193:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:DOG:193:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "YCOR:DOG:193:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "YCOR:DOG:193:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "YCOR:DOG:193:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "YCOR:DOG:193:TRIMTYPE.RVAL")
  field(INPB,   "YCOR:DOG:193:CONFIG.RVAL")
  field(OUT,    "YCOR:DOG:193:TRIMMAXNUM PP")
}
record(longout, "YCOR:DOG:193:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "YCOR:DOG:193:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "YCOR:DOG:193:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "YCOR:DOG:193:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "YCOR:DOG:193:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "YCOR:DOG:193:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "YCOR:DOG:193:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "YCOR:DOG:193:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "YCOR:DOG:193:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "YCOR:DOG:193:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "YCOR:DOG:193:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "YCOR:DOG:193:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "YCOR:DOG:193:IMOVE")
 field(INPB, "YCOR:DOG:193:IACT")
 field(INPC, "YCOR:DOG:193:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "YCOR:DOG:193:TRIMDLYPCT")
 field(INPF, "YCOR:DOG:193:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "YCOR:DOG:193:RAMPTIME_LEFT PP")
}

record(longout, "YCOR:DOG:193:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "YCOR:DOG:193:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "YCOR:DOG:193:RAMPDONE_CALC")
}

record(calc, "YCOR:DOG:193:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "YCOR:DOG:193:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "YCOR:DOG:193:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "YCOR:DOG:193:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:DOG:193:RAMPTIME_LEFT")
 field(OUT,  "YCOR:DOG:193:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "YCOR:DOG:193:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:DOG:193:RAMPTIME_LEFT NMS")
 field(OUT,  "YCOR:DOG:193:RAMPDONE PP")
}

record(bo, "YCOR:DOG:193:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "YCOR:DOG:193:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "YCOR:DOG:193:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "YCOR:DOG:193:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:193:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "YCOR:DOG:193:DEBUG.PROC PP")
  field(LNK2, "YCOR:DOG:193:STDZCYCLENUM.PROC PP")
  field(LNK3, "YCOR:DOG:193:STDZDISABLE.PROC PP")
  field(LNK4, "YCOR:DOG:193:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "YCOR:DOG:193:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "YCOR:DOG:193:STDZIMIN NPP NMS")
  field(INPB, "YCOR:DOG:193:STDZIMAX NPP NMS")
  field(INPC, "YCOR:DOG:193:STDZIFINAL NPP NMS")
  field(INPD, "YCOR:DOG:193:STDZCYCLENUM NPP NMS")
  field(INPE, "YCOR:DOG:193:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "YCOR:DOG:193:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "YCOR:DOG:193:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "YCOR:DOG:193:STDZWF PP")
  field(OUTB, "YCOR:DOG:193:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "YCOR:DOG:193:STDZWF")
}

record(mbbo, "YCOR:DOG:193:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "YCOR:DOG:193:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "YCOR:DOG:193:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "YCOR:DOG:193:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "YCOR:DOG:193:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "YCOR:DOG:193:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "YCOR:DOG:193:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:DOG:193:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:DOG:193:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "YCOR:DOG:193:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:193:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "YCOR:DOG:193:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "YCOR:DOG:193:STDZIMIN")
}

record(ao, "YCOR:DOG:193:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "YCOR:DOG:193:STDZIMAX")
}

record(ao, "YCOR:DOG:193:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:193:STDZIFINAL")
}

record(ao, "YCOR:DOG:193:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "YCOR:DOG:193:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "YCOR:DOG:193:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "YCOR:DOG:193:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "YCOR:DOG:193:STDZIMIN CP NMS")
  field(INPB, "YCOR:DOG:193:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "YCOR:DOG:193:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "YCOR:DOG:193:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "YCOR:DOG:193:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "YCOR:DOG:193:STDZIMIN CP NMS")
  field(INPB, "YCOR:DOG:193:STDZIMAX CP NMS")
  field(INPC, "YCOR:DOG:193:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:193:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "YCOR:DOG:193:TRIMDLYPCT CP MS")
  field(INPB, "YCOR:DOG:193:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "YCOR:DOG:193:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "YCOR:DOG:193:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:193:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "YCOR:DOG:193:IDES.HOPR")
  field(INPB, "YCOR:DOG:193:STDZMINIPCT CPP NMS")
  field(INPC, "YCOR:DOG:193:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "YCOR:DOG:193:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "YCOR:DOG:193:IDES.HOPR")
  field(INPB, "YCOR:DOG:193:IDES.LOPR")
  field(INPC, "YCOR:DOG:193:STDZDIRECT.RVAL")
  field(INPD, "YCOR:DOG:193:STDZMINIDELTA")
  field(INPE, "YCOR:DOG:193:IDES")
  field(PREC, "5")
  field(FLNK, "YCOR:DOG:193:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "YCOR:DOG:193:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "YCOR:DOG:193:IDES.HOPR")
  field(INPB, "YCOR:DOG:193:IDES.LOPR")
  field(INPC, "YCOR:DOG:193:STDZDIRECT.RVAL")
  field(INPD, "YCOR:DOG:193:STDZMINIDELTA")
  field(INPE, "YCOR:DOG:193:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "YCOR:DOG:193:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "YCOR:DOG:193:IADJUST.RVAL")
  field(INPB, "YCOR:DOG:193:STDZDIRECT.RVAL")
  field(INPC, "YCOR:DOG:193:STDZOK.RVAL")
  field(INPD, "YCOR:DOG:193:STDZDISABLE.RVAL")
  field(INPE, "YCOR:DOG:193:STATE.RVAL CPP NMS")
  field(INPF, "YCOR:DOG:193:ICTRL.RVAL")
  field(INPG, "YCOR:DOG:193:STATE.SEVR")
  field(INPH, "YCOR:DOG:193:BDELTAS.M")
  field(INPI, "YCOR:DOG:193:IACT.SEVR")
  field(OUT,  "YCOR:DOG:193:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "YCOR:DOG:193:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "YCOR:DOG:193:STDZLOSTTOD.PROC")
  field(LNK2, "YCOR:DOG:193:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "YCOR:DOG:193:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:193:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:DOG:193:IACT CP")
  field(INPB, "YCOR:DOG:193:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "YCOR:DOG:193:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "YCOR:DOG:193:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:193:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:DOG:193:STDZIACTMAX")
  field(INPB, "YCOR:DOG:193:IACT")
  field(INPC, "YCOR:DOG:193:IDELTAS.I")
  field(OUT,  "YCOR:DOG:193:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "YCOR:DOG:193:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "YCOR:DOG:193:STDZOK.RVAL CP")
  field(INPB, "YCOR:DOG:193:STDZDISABLE.RVAL CP")
  field(INPC, "YCOR:DOG:193:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "YCOR:DOG:193:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "YCOR:DOG:193:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "YCOR:DOG:193:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "YCOR:DOG:193:CALBOK")
  field(INPB, "YCOR:DOG:193:CALBDISABLE")
  field(INPC, "YCOR:DOG:193:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "YCOR:DOG:193:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "YCOR:DOG:193:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "YCOR:DOG:193:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "YCOR:DOG:193:CALBSLOPE")
  field(DOL3, "YCOR:DOG:193:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "YCOR:DOG:193:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:193:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "YCOR:DOG:193:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "YCOR:DOG:193:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "YCOR:DOG:193:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "YCOR:DOG:193:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "YCOR:DOG:193:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:193:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "YCOR:DOG:193:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:193:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "YCOR:DOG:193:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "YCOR:DOG:193:IACT")
  field(INPD, "YCOR:DOG:193:DACSLOPE")
  field(INPE, "YCOR:DOG:193:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "YCOR:DOG:193:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "YCOR:DOG:193:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "2")
  field(HOPR, "2")
  field(DRVL, "-2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "YCOR:DOG:193:CALBIMAX")
}

record(ao, "YCOR:DOG:193:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "2")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:193:CALBSTEPNUM")
}

record(ao, "YCOR:DOG:193:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL, "0")
}

record(longout, "YCOR:DOG:193:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:DOG:193:CALBIDELTA")
}

record(calc, "YCOR:DOG:193:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "YCOR:DOG:193:CALBIMAX")
  field(INPB, "YCOR:DOG:193:CALBIMIN")
  field(INPC, "YCOR:DOG:193:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "YCOR:DOG:193:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:209:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:209:IACT.HOPR")
  field(INPC, "YCOR:DOG:193:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "YCOR:DOG:193:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:DOG:193:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:193:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:193:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:193:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "YCOR:DOG:193:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:193:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:193:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:193:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "YCOR:DOG:193:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:193:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:193:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:193:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:DOG:193:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:193:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:193:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "YCOR:DOG:193:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:193:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "YCOR:DOG:193:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "YCOR:DOG:193:CALBSTEPNUM")
  field(INPB, "YCOR:DOG:193:CALBIACTWF")
  field(INPC, "YCOR:DOG:193:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "YCOR:DOG:193:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "YCOR:DOG:193:STDZITOL")

  field(INPH, "YCOR:DOG:193:DACSLOPE")
  field(INPI, "YCOR:DOG:193:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "YCOR:DOG:193:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "YCOR:DOG:193:CALBSTEPNUM")
  field(INPB, "YCOR:DOG:193:CALBIACTWF")
  field(INPC, "YCOR:DOG:193:DACWF")
  field(INPF, "YCOR:DOG:193:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe YCOR:DOG:193CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "YCOR:DOG:193:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "YCOR:DOG:193:DEGAUSIMIN.PROC PP")
  field(OUTB, "YCOR:DOG:193:DEGAUSIMAX.PROC PP")
  field(OUTC, "YCOR:DOG:193:DEGAUSTYPE.PROC PP")
  field(OUTD, "YCOR:DOG:193:DEGAUSSTEP.PROC PP")
  field(OUTE, "YCOR:DOG:193:MADNAME.PROC PP")
  field(OUTF, "YCOR:DOG:193:PSTYPE.PROC PP")
  field(OUTG, "YCOR:DOG:193:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "YCOR:DOG:193:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:DOG:193:DEGAUSIMIN NPP NMS")
  field(INPB, "YCOR:DOG:193:DEGAUSIMAX NPP NMS")
  field(INPC, "YCOR:DOG:193:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "YCOR:DOG:193:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "YCOR:DOG:193:PSTYPE NPP NMS")
  field(INPG, "YCOR:DOG:193:DEBUG.RVAL NPP NMS")
  field(INPH, "YCOR:DOG:193:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "YCOR:DOG:193:DEGAUSWF PP")
  field(OUTB, "YCOR:DOG:193:DEGAUSMSG PP")
  field(OUTC, "YCOR:DOG:193:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "YCOR:DOG:193:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"YCOR:DOG:193:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "YCOR:DOG:193:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "YCOR:DOG:193:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "YCOR:DOG:193:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "YCOR:DOG:193:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "YCOR:DOG:193:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "-2")
}
record(ao, "YCOR:DOG:193:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"YCOR:DOG:193:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "YCOR:DOG:193:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"YCOR:DOG:193:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "YCOR:DOG:193:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "YCOR:DOG:193:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "YCOR:DOG:193:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "YCOR:DOG:193:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:DOG:193:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:193:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:DOG:193:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:DOG:193:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "YCOR:DOG:193:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "YCOR:DOG:193:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "YCOR:DOG:193:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "YCOR:DOG:193:DEGAUS_IMAX")
  field(INPB, "YCOR:DOG:193:ISETPT")
  field(INPC, "YCOR:DOG:193:DEGAUSTYPE.RVAL")
  field(OUT,  "YCOR:DOG:193:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "YCOR:DOG:193:DEGAUS_IMAX_UPDATE")
}
record(seq, "YCOR:DOG:193:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "YCOR:DOG:193:ISETPT")
  field(LNK1, "YCOR:DOG:193:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "YCOR:DOG:193:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:193:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "YCOR:DOG:193:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "YCOR:DOG:193:DEGAUS_IMAX")
  field(FLNK, "YCOR:DOG:193:DEGAUS_IMAXPOL")
}
record(bo, "YCOR:DOG:193:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:DOG:193:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "YCOR:DOG:193:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "YCOR:DOG:193:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "YCOR:DOG:193:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "YCOR:DOG:193:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "YCOR:DOG:193:IACT")
  field(INPB, "YCOR:DOG:193:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "YCOR:DOG:193:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "YCOR:DOG:193:IACTPOL")
}
record(bo, "YCOR:DOG:193:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"YCOR:DOG:193:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "YCOR:DOG:193:DEGAUSENABLE CP")
  field(INPB, "YCOR:DOG:193:DEGAUSOK")
  field(INPC, "YCOR:DOG:193:STATE CP")
  field(INPD, "YCOR:DOG:193:STATE.SEVR")
  field(OUT,  "YCOR:DOG:193:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "YCOR:DOG:193:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "YCOR:DOG:193:DEGAUS_STATE_CHECK")
  field(LNK1, "YCOR:DOG:193:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "YCOR:DOG:193:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "YCOR:DOG:193:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "YCOR:DOG:193:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "YCOR:DOG:193:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "YCOR:DOG:193:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:DOG:193:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "YCOR:DOG:193:STATMSG.FRSV")
  field(LNK4, "YCOR:DOG:193:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:DOG:193:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:193:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:DOG:193:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "YCOR:DOG:193:STATMSG.FRSV")
  field(LNK4, "YCOR:DOG:193:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:DOG:193:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "YCOR:DOG:193:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "YCOR:DOG:193:STATMSG.FRSV")
  field(LNK3, "YCOR:DOG:193:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "YCOR:DOG:193:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:193:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "YCOR:DOG:193:STATMSG.FRSV PP")
  field(LNK3, "YCOR:DOG:193:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "YCOR:DOG:193:FUNC") {
  field(DESC, "YCOR:DOG:193 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "YCOR:DOG:193:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:DOG:193:CTRL") {
  field(DESC, "YCOR:DOG:193 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "YCOR:DOG:193:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "YCOR:DOG:193:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "YCOR:DOG:193:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "YCOR:DOG:193:BUSY") {
  field(DESC, "YCOR:DOG:193 Ctrl Done")
  field(DOL, "YCOR:DOG:193:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:193:SELECT")
}

record(bo, "YCOR:DOG:193:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "YCOR:DOG:193:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:DOG:193:CTRLSTATE") {
  field(DESC, "YCOR:DOG:193 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("YCOR:DOG:193:CTRL",20,20,0,0,"YCOR:DOG:193:CTRL")
#! Field("YCOR:DOG:193:CTRL.OUT",16777215,1,"YCOR:DOG:193:CTRL.OUT")
#! Link("YCOR:DOG:193:CTRL.OUT","YCOR:DOG:193:SELECTEN.A")
#! Field("YCOR:DOG:193:CTRL.VAL",16777215,1,"YCOR:DOG:193:CTRL.VAL")
#! Record("YCOR:DOG:193:SELECTEN",321,381,0,0,"YCOR:DOG:193:SELECTEN")
#! Field("YCOR:DOG:193:SELECTEN.A",16777215,0,"YCOR:DOG:193:SELECTEN.A")
#! Field("YCOR:DOG:193:SELECTEN.FLNK",16777215,1,"YCOR:DOG:193:SELECTEN.FLNK")
#! Link("YCOR:DOG:193:SELECTEN.FLNK","YCOR:DOG:193:BUSY")
#! Field("YCOR:DOG:193:SELECTEN.VAL",16777215,1,"YCOR:DOG:193:SELECTEN.VAL")
#! Record("YCOR:DOG:193:BUSY",623,274,0,0,"YCOR:DOG:193:BUSY")
#! Field("YCOR:DOG:193:BUSY.DOL",16777215,0,"YCOR:DOG:193:BUSY.DOL")
#! Link("YCOR:DOG:193:BUSY.DOL","YCOR:DOG:193:SELECTEN.VAL")
#! Field("YCOR:DOG:193:BUSY.FLNK",16777215,1,"YCOR:DOG:193:BUSY.FLNK")
#! Link("YCOR:DOG:193:BUSY.FLNK","YCOR:DOG:193:SELECT")
#! Record("YCOR:DOG:193:SELECT",669,508,0,1,"YCOR:DOG:193:SELECT")
#! Record("YCOR:DOG:193:FUNC",940,120,0,0,"YCOR:DOG:193:FUNC")
#! Field("YCOR:DOG:193:FUNC.OUT",16777215,0,"YCOR:DOG:193:FUNC.OUT")
#! Link("YCOR:DOG:193:FUNC.OUT","YCOR:DOG:193:CTRL.VAL")
#! Record("YCOR:DOG:193:ABORT",193,41,0,0,"YCOR:DOG:193:ABORT")
#! Record("YCOR:DOG:193:CTRLSTATE",369,34,0,0,"YCOR:DOG:193:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"YCOR:DOG:193:SELECT is used for Multi-device selection.\nIt is enabled when associated YCOR:DOG:193:CTRL is \"0\" (DONE).\nIt is disabled when associated YCOR:DOG:193:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"YCOR:DOG:193:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "YCOR:DOG:193:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "YCOR:DOG:193:BCTRL.SEVR")
  field(OUT,  "YCOR:DOG:193:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "YCOR:DOG:193:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:DOG:193:BACT")
  field(INPB, "YCOR:DOG:193:POLYCOEF")
  field(INPC, "YCOR:DOG:193:POLYCOEF.A")
  field(INPD, "YCOR:DOG:193:POLYCOEF.B")
  field(INPE, "YCOR:DOG:193:IACT MS")
  field(INPF, "YCOR:DOG:193:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
  field(FLNK, "YCOR:DOG:193:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "YCOR:DOG:193:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:DOG:193:BDES")
  field(INPB, "YCOR:DOG:193:TRIMBTOL")
  field(INPC, "YCOR:DOG:193:TRIMBTOLR")
  field(INPD, "YCOR:DOG:193:CHCKBTOL")
  field(INPE, "YCOR:DOG:193:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "YCOR:DOG:193:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "YCOR:DOG:193:MPSBTOL")
  field(INPQ, "YCOR:DOG:193:MPSBTOLR")
  field(FLNK, "YCOR:DOG:193:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "YCOR:DOG:193:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "YCOR:DOG:193:BDES")
  field(INPB, "YCOR:DOG:193:BDELTAS.I")
  field(INPG, "YCOR:DOG:193:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "YCOR:DOG:193:BCON.HIGH")
  field(OUTB, "YCOR:DOG:193:BCON.LOW")
  field(OUTC, "YCOR:DOG:193:BCON.HIHI")
  field(OUTD, "YCOR:DOG:193:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:193:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "YCOR:DOG:193:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:DOG:193:BDIFF")
  field(LNK2, "YCOR:DOG:193:BADIFF")
  field(LNK3, "YCOR:DOG:193:BRATIO")
  field(LNK4, "YCOR:DOG:193:MPSLIMITS")
  field(LNK5, "YCOR:DOG:193:I2BSTATUS")
  field(LNK6, "YCOR:DOG:193:IACTFO.PROC")
}

record(calc, "YCOR:DOG:193:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:DOG:193:BDES")
  field(INPB, "YCOR:DOG:193:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "YCOR:DOG:193:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "YCOR:DOG:193:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "YCOR:DOG:193:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:DOG:193:BDIFF")
  field(INPB, "YCOR:DOG:193:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "YCOR:DOG:193:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "YCOR:DOG:193:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "YCOR:DOG:193:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:DOG:193:BMON")
  field(INPB, "YCOR:DOG:193:POLYCOEF")
  field(INPC, "YCOR:DOG:193:POLYCOEF.A")
  field(INPD, "YCOR:DOG:193:POLYCOEF.B")
  field(INPE, "YCOR:DOG:193:IMON MS")
  field(INPF, "YCOR:DOG:193:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:209:BDES CP
record(ao,  "YCOR:DOG:193:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.02098636")
   field(DRVL, "-0.02098636")
   field(HOPR, "0.02098636")
   field(LOPR, "-0.02098636")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "YCOR:DOG:193:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "YCOR:DOG:193:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:193:POLYCOEF")
  field(INPC, "YCOR:DOG:193:POLYCOEF.A")
  field(INPD, "YCOR:DOG:193:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "YCOR:DOG:193:BDES.DRVH")
  field(INPF, "YCOR:DOG:193:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:193:IDES")
}
record(sub, "YCOR:DOG:193:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:193:POLYCOEF")
  field(INPC, "YCOR:DOG:193:POLYCOEF.A")
  field(INPD, "YCOR:DOG:193:POLYCOEF.B")
  field(INPE, "YCOR:DOG:193:BDES.DRVH")
  field(INPF, "YCOR:DOG:193:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "YCOR:DOG:193:INOM")
}

record(sub, "YCOR:DOG:193:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:193:BDES.VAL")
  field(INPB, "YCOR:DOG:193:BDES.DRVH")
  field(INPC, "YCOR:DOG:193:BDES.DRVL")
  field(INPD, "YCOR:DOG:193:BDELTAS.I")
  field(INPE, "YCOR:DOG:193:BDELTAS.J")
  field(INPG, "YCOR:DOG:193:STATE")
  field(INPH, "YCOR:DOG:193:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:DOG:193:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:193:BDES.VAL")
  field(INPB, "YCOR:DOG:193:BDES.DRVH")
  field(INPC, "YCOR:DOG:193:BDES.DRVL")
  field(INPD, "YCOR:DOG:193:BDELTAS.K")
  field(INPE, "YCOR:DOG:193:BDELTAS.L")
  field(INPG, "YCOR:DOG:193:STATE")
  field(INPH, "YCOR:DOG:193:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:DOG:193:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "YCOR:DOG:193:BLIMITS")
  field(LNK1, "YCOR:DOG:193:BACTLIMITS.F PP")
  field(DOL2, "YCOR:DOG:193:BACTLIMITS.I")
  field(LNK2, "YCOR:DOG:193:BACT.HIGH")
  field(DOL3, "YCOR:DOG:193:BACTLIMITS.J")
  field(LNK3, "YCOR:DOG:193:BACT.LOW")
  field(DOL4, "YCOR:DOG:193:BACTLIMITS.K")
  field(LNK4, "YCOR:DOG:193:BACT.HIHI")
  field(DOL5, "YCOR:DOG:193:BACTLIMITS.L")
  field(LNK5, "YCOR:DOG:193:BACT.LOLO")
  field(DOL6, "YCOR:DOG:193:BLIMITS")
  field(LNK6, "YCOR:DOG:193:BMONLIMITS.F PP")
  field(DOL7, "YCOR:DOG:193:BMONLIMITS.I")
  field(LNK7, "YCOR:DOG:193:BMON.HIGH")
  field(DOL8, "YCOR:DOG:193:BMONLIMITS.J")
  field(LNK8, "YCOR:DOG:193:BMON.LOW")
  field(DOL9, "YCOR:DOG:193:BMONLIMITS.K")
  field(LNK9, "YCOR:DOG:193:BMON.HIHI")
  field(DOLA, "YCOR:DOG:193:BMONLIMITS.L")
  field(LNKA, "YCOR:DOG:193:BMON.LOLO")
  field(FLNK, "YCOR:DOG:193:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "YCOR:DOG:193:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "YCOR:DOG:193:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "YCOR:DOG:193:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:193:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "YCOR:DOG:193:BCTRL.VAL")
  field(LNK2, "YCOR:DOG:193:BDES PP")

  field(DOL3, "1")
  field(LNK3, "YCOR:DOG:193:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "YCOR:DOG:193:CHECKSTDZLOST.PROC PP")

  field(DOL5, "YCOR:DOG:193:BCTRL.VAL")
  field(LNK5, "YCOR:DOG:193:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "YCOR:DOG:193:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "YCOR:DOG:193:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:193:POLYCOEF")
  field(INPC, "YCOR:DOG:193:POLYCOEF.A")
  field(INPD, "YCOR:DOG:193:POLYCOEF.B")
  field(INPE, "YCOR:DOG:193:BDES.DRVH")
  field(INPF, "YCOR:DOG:193:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:193:ISETPT")
}

record(ao, "YCOR:DOG:193:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "YCOR:DOG:193:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "YCDOG6")
}

record(ai, "YCOR:DOG:193:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "719.313595")
}

record(ao, "YCOR:DOG:193:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(FLNK, "YCOR:DOG:193:BSTEP")
}

record(ao, "YCOR:DOG:193:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(FLNK, "YCOR:DOG:193:BSTEP")
}

record(ao, "YCOR:DOG:193:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by YCOR:DOG:193:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "YCOR:DOG:193:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "YCOR:DOG:193:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "YCOR:DOG:193:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:193:POLYCOEF")
  field(INPC, "YCOR:DOG:193:POLYCOEF.A")
  field(INPD, "YCOR:DOG:193:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "YCOR:DOG:193:BCON.DRVH")
  field(INPF, "YCOR:DOG:193:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:193:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "YCOR:DOG:193:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "YCOR:DOG:193:BMAX")
  field(INPB, "YCOR:DOG:193:BMIN")
  field(INPC, "YCOR:DOG:193:BMIN.SEVR")
  field(INPD, "YCOR:DOG:193:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"YCOR:DOG:193:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "YCOR:DOG:193:ONLINE CP")
  field(OUT,  "YCOR:DOG:193:BCTRLDISABLEFOUT PP")
}

record(fanout, "YCOR:DOG:193:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "YCOR:DOG:193:BCTRLDISABLECALC")
  field(LNK1, "YCOR:DOG:193:BCTRLDISABLE")
  field(LNK2, "YCOR:DOG:193:BCTRLENABLE")
}

record(stringout, "YCOR:DOG:193:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:DOG:193:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "YCOR:DOG:193:BCTRLDISV_UPDATE")
}

record(stringout, "YCOR:DOG:193:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:DOG:193:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "YCOR:DOG:193:BCTRLDISV_UPDATE")
}

record(calcout, "YCOR:DOG:193:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "YCOR:DOG:193:ONLINE")
  field(OUT,  "YCOR:DOG:193:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"YCOR:DOG:193:BACT and MON\n  are processed via links from \n  YCOR:DOG:193:IACT (device raw value readback 1)\n  and\n  YCOR:DOG:193:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from YCOR:DOG:193:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = YCOR:DOG:193:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"YCOR:DOG:193:BDES\n  is processed when set by CA users or \n  YCOR:DOG:193:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"YCOR:DOG:193:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  YCOR:DOG:193:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (YCOR:DOG:193:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"YCOR:DOG:193:B*LIMITS and YCOR:DOG:193:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:DOG:193:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"YCOR:DOG:193:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"YCOR:DOG:193:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "YCOR:DOG:193:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:193:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "YCOR:DOG:193:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "YCOR:DOG:193:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:193:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:193:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:193:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "YCOR:DOG:193:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "YCOR:DOG:193:MPSLIMITS.E PP")
}

record(aSub, "YCOR:DOG:193:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "YCOR:DOG:193:MPS.RVAL")
  field(INPB, "YCOR:DOG:193:BADIFF")
  field(INPC, "YCOR:DOG:193:BDELTAS.N")
  field(INPD, "YCOR:DOG:193:BACT")
  field(INPE, "YCOR:DOG:193:MPSBITMASK.RVAL")
  field(INPF, "YCOR:DOG:193:MPSBLLIM")
  field(INPG, "YCOR:DOG:193:MPSBMIN")
  field(INPH, "YCOR:DOG:193:MPSBMAX")
  field(INPI, "YCOR:DOG:193:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "YCOR:DOG:193:INTOL.RVAL PP")
  field(OUTB, "YCOR:DOG:193:INTOL_BMIN.RVAL PP")
  field(OUTC, "YCOR:DOG:193:INTOL_BRANGE.RVAL PP")
  field(OUTD, "YCOR:DOG:193:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "YCOR:DOG:193:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:193:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:193:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:193:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:193:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:193:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:193:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:193:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "YCOR:DOG:193:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "YCOR:DOG:193:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:DOG:193:CHCKBTOL")
  field(INPB, "YCOR:DOG:193:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "YCOR:DOG:193:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "YCOR:DOG:193:CHCKBTOL")
  field(FLNK, "YCOR:DOG:193:CHCKITOL")
}

record(calc, "YCOR:DOG:193:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "YCOR:DOG:193:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "YCOR:DOG:193:BDES.HOPR")
  field(INPB, "YCOR:DOG:193:STABILITY")
  field(INPC, "YCOR:DOG:193:BDES.LOPR")
}

record(longout, "YCOR:DOG:193:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "YCOR:DOG:193:CHCKBTOL")
}

record(calc, "YCOR:DOG:193:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:DOG:193:POLYCOEF.B")
  field(INPB, "YCOR:DOG:193:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "YCOR:DOG:193:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "YCOR:DOG:193:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "YCOR:DOG:193:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "YCOR:DOG:193:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "YCOR:DOG:193:PAUGO")  
}

record(fanout, "YCOR:DOG:193:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "YCOR:DOG:193:PAUSTOP")
  field(LNK2, "YCOR:DOG:193:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "YCOR:DOG:193:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "YCOR:DOG:193:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:209:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:209:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "YCOR:DOG:193:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "YCOR:DOG:193:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:209:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:209:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "YCOR:DOG:193:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:209:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:DOG:193:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "YCOR:DOG:193:PSTYPE.RVAL")
  field(INPC, "YCOR:DOG:193:TURNEDOFF.RVAL")
  field(INPD, "YCOR:DOG:193:CONFIG.RVAL")
  field(INPE, "YCOR:DOG:193:PSCATEGORY.RVAL")
  field(INPF, "YCOR:DOG:193:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "YCOR:DOG:193:AUTOCTRL.RVAL")
  field(INPJ, "YCOR:DOG:193:OUTOFSERVICE.RVAL")
  field(INPL, "YCOR:DOG:193:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "YCOR:DOG:193:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "YCOR:DOG:193:PAU")
  field(INPP, "YCOR:DOG:193:CALBDISABLE.RVAL")
  field(INPQ, "YCOR:DOG:193:PTRBDISABLE.RVAL")
  field(INPR, "YCOR:DOG:193:TRIMDISABLE.RVAL")
  field(INPS, "YCOR:DOG:193:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "YCOR:DOG:193:FBCK")
  field(INPU, "YCOR:DOG:193:TRIMTYPE.RVAL")
  field(INPV, "YCOR:DOG:193:STDZDIRECT.RVAL")
  field(INPW, "YCOR:DOG:193:DEGAUSENABLE.RVAL")
  field(FLNK, "YCOR:DOG:193:HSTA")
}

record(longin, "YCOR:DOG:193:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "YCOR:DOG:193:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "YCOR:DOG:193:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "YCOR:DOG:193:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "YCOR:DOG:193:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:193:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:193:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:193:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by YCOR:DOG:193:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses YCOR:DOG:193:FBCK.
# This PV should be replaced by YCOR:DOG:193:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "YCOR:DOG:193:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "YCOR:DOG:193:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:DOG:193:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:193:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"YCOR:DOG:193:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "YCOR:DOG:193:OUTOFSERVICE NPP NMS")
  field(OUT,  "YCOR:DOG:193:ONLINE PP")
}
record(bo, "YCOR:DOG:193:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "YCOR:DOG:193:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:DOG:193:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "YCOR:DOG:193:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "YCOR:DOG:193:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "YCOR:DOG:193:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "YCOR:DOG:193:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "YCOR:DOG:193:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "YCOR:DOG:193:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:193:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:193:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:193:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "YCOR:DOG:193:TRIMTYPE")
}

record(stringout, "YCOR:DOG:193:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "YCOR:DOG:193:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "YCOR:DOG:193:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "YCOR:DOG:193:STATE.RVAL")
  field(INPB, "YCOR:DOG:193:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:DOG:193:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:DOG:193:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "YCOR:DOG:193:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "YCOR:DOG:193:STATE.RVAL")
  field(INPB, "YCOR:DOG:193:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:DOG:193:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:DOG:193:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "YCOR:DOG:193:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "YCOR:DOG:193:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "YCOR:DOG:193:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "YCOR:DOG:193:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "YCOR:DOG:193:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"YCOR:DOG:193:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("YCOR:DOG:193:TURNEDOFF",3140,1907,0,1,"YCOR:DOG:193:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:DOG:193:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "YCOR:DOG:193:BACT.STAT")
  field(INPB, "YCOR:DOG:193:BDES.STAT")
  field(INPC, "YCOR:DOG:193:IRIPL.STAT")
  field(INPD, "MCOR:EXT:209:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:209:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "YCOR:DOG:193:BACT.SEVR")
  field(INPH, "YCOR:DOG:193:BDES.SEVR")
  field(INPI, "YCOR:DOG:193:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:209:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:209:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "YCOR:DOG:193:STATE.RVAL")
  field(INPN, "YCOR:DOG:193:STDZOK")
  field(INPO, "YCOR:DOG:193:CALBOK")
  field(INPP, "YCOR:DOG:193:OUTOFSERVICE.RVAL")
  field(INPQ, "YCOR:DOG:193:CONFIG.RVAL")
  field(INPR, "YCOR:DOG:193:HSTA")
  field(INPS, "YCOR:DOG:193:CTRL.RVAL")
  field(INPT, "YCOR:DOG:193:DEGAUSOK") 
  field(INPV, "YCOR:DOG:193:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:193:STAT")
}

record(longout, "YCOR:DOG:193:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "YCOR:DOG:193:STATCTRLSUB")
  field(DOL, "YCOR:DOG:193:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "YCOR:DOG:193:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "YCOR:DOG:193:STAT")
  field(INPB, "YCOR:DOG:193:HSTA")
  field(INPD, "YCOR:DOG:193:ONOFFCTRL.RVAL")
  field(FLNK, "YCOR:DOG:193:STATMSG")
}

record(mbbo, "YCOR:DOG:193:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:DOG:193:UNAVAILGO")
  field(DOL, "YCOR:DOG:193:STATCTRLSUB.W")
}

record(seq, "YCOR:DOG:193:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "YCOR:DOG:193:STATSUB.U")
  field(LNK1, "YCOR:DOG:193:UNAVAIL PP")
}

record(stringout, "YCOR:DOG:193:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"YCOR:DOG:193:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - YCOR:DOG:193:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - YCOR:DOG:193:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"YCOR:DOG:193STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - YCOR:DOG:193:STATUS\nC - YCOR:DOG:193:ON\nD - YCOR:DOG:193:STDZOK\nE - YCOR:DOG:193:CALBOK\nF - YCOR:DOG:193:BACTDRIFT (future)\nG -\nH- YCOR:DOG:193:DACSTATUS\nI -YCOR:DOG:193:ADCSTATUS\nJ - YCOR:DOG:193:BACTSTATUS\nK - YCOR:DOG:193:BDESSTATUS\nL - YCOR:DOG:193:RIPLSTATUS\n\nOutput:\nP - YCOR:DOG:193:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "YCOR:DOG:193:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "YCOR:DOG:193:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "YCOR:DOG:193:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "YCOR:DOG:193:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "XCOR:DOG:212:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:210:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:DOG:212:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "XCOR:DOG:212:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:210:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "XCOR:DOG:212:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "2")
  field(LOLO, "-2")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "XCOR:DOG:212:BDELTAS")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "XCOR:DOG:212:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "XCOR:DOG:212:ICTRL PP")
}

# This record is processed by XCOR:DOG:212:ICON")
# Note: we are not setting alarms here.
record(ao, "XCOR:DOG:212:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "XCOR:DOG:212:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:212:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "XCOR:DOG:212:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(ao, "XCOR:DOG:212:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(FLNK, "XCOR:DOG:212:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "XCOR:DOG:212:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "XCOR:DOG:212:ISETPT.OMSL")

  field(DOL2, "XCOR:DOG:212:ICTRL")
  field(LNK2, "XCOR:DOG:212:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "XCOR:DOG:212:ISETPT.OMSL")
}

record(ao, "XCOR:DOG:212:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:212:IMIN")
}

record(ao, "XCOR:DOG:212:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(VAL,  "-2")
  field(FLNK, "XCOR:DOG:212:IRANGE")
}

record(sel, "XCOR:DOG:212:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(NVL,  "XCOR:DOG:212:BACT.SEVR")
  field(INPA, "XCOR:DOG:212:IACT NPP MS")
  field(INPB, "XCOR:DOG:212:IACTPREVOK NPP MS")
  field(INPC, "XCOR:DOG:212:IACTPREVOK NPP MS")
  field(INPD, "XCOR:DOG:212:IACTPREVOK NPP MS")
}

record(sub, "XCOR:DOG:212:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:212:IDES")
  field(INPB, "XCOR:DOG:212:ISETPT.DRVH")
  field(INPC, "XCOR:DOG:212:ISETPT.DRVL")
  field(INPD, "XCOR:DOG:212:IDELTAS.I")
  field(INPE, "XCOR:DOG:212:IDELTAS.J")
  field(INPG, "XCOR:DOG:212:STATE")
  field(INPH, "XCOR:DOG:212:HSTA")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:DOG:212:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:212:IDES")
  field(INPB, "XCOR:DOG:212:ISETPT.DRVH")
  field(INPC, "XCOR:DOG:212:ISETPT.DRVL")
  field(INPD, "XCOR:DOG:212:IDELTAS.K")
  field(INPE, "XCOR:DOG:212:IDELTAS.L")
  field(INPG, "XCOR:DOG:212:STATE")
  field(INPH, "XCOR:DOG:212:HSTA")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:DOG:212:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "XCOR:DOG:212:BLIMITS")
  field(LNK1, "XCOR:DOG:212:IACTLIMITS.F PP")
  field(DOL2, "XCOR:DOG:212:IACTLIMITS.I")
  field(LNK2, "XCOR:DOG:212:IACT.HIGH")
  field(DOL3, "XCOR:DOG:212:IACTLIMITS.J")
  field(LNK3, "XCOR:DOG:212:IACT.LOW")
  field(DOL4, "XCOR:DOG:212:IACTLIMITS.K")
  field(LNK4, "XCOR:DOG:212:IACT.HIHI")
  field(DOL5, "XCOR:DOG:212:IACTLIMITS.L")
  field(LNK5, "XCOR:DOG:212:IACT.LOLO")
  field(DOL6, "XCOR:DOG:212:BLIMITS")
  field(LNK6, "XCOR:DOG:212:IMONLIMITS.F PP")
  field(DOL7, "XCOR:DOG:212:IMONLIMITS.I")
  field(LNK7, "XCOR:DOG:212:IMON.HIGH")
  field(DOL8, "XCOR:DOG:212:IMONLIMITS.J")
  field(LNK8, "XCOR:DOG:212:IMON.LOW")
  field(DOL9, "XCOR:DOG:212:IMONLIMITS.K")
  field(LNK9, "XCOR:DOG:212:IMON.HIHI")
  field(DOLA, "XCOR:DOG:212:IMONLIMITS.L")
  field(LNKA, "XCOR:DOG:212:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "XCOR:DOG:212:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "XCOR:DOG:212:TRIMBTOL")
  field(INPE, "XCOR:DOG:212:CHCKBTOL")
  field(INPF, "XCOR:DOG:212:BDELTAS.K")
  field(INPG, "XCOR:DOG:212:BDELTAS.L")
  field(INPH, "XCOR:DOG:212:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "XCOR:DOG:212:STDZITOLR")
  field(INPC, "XCOR:DOG:212:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:210:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "XCOR:DOG:212:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:210:RESET PP
#
record(bo, "XCOR:DOG:212:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:210:RESET PP")
}

record(bo, "XCOR:DOG:212:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:210:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "XCOR:DOG:212:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "XCOR:DOG:212:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:210:IRAMPRATE PP")
  field(FLNK, "XCOR:DOG:212:STDZDLY")
}


record(ao, "XCOR:DOG:212:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:210:ISETPT PP")
  field(DOL, "XCOR:DOG:212:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "XCOR:DOG:212:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:210:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:DOG:212:BMON")
}

record(ao, "XCOR:DOG:212:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:210:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "XCOR:DOG:212:IRIPLOK")
}

record(sub, "XCOR:DOG:212:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "XCOR:DOG:212:IRIPL.VAL")
  field(INPB, "XCOR:DOG:212:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:DOG:212:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:DOG:212:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "XCOR:DOG:212:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:210:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "XCOR:DOG:212:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:210:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "XCOR:DOG:212:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:DOG:212:IACTPREVOK")
  field(LNK2, "XCOR:DOG:212:IDIFF")
  field(LNK3, "XCOR:DOG:212:IADIFF")
  field(LNK4, "XCOR:DOG:212:IRATIO")
  field(LNK5, "XCOR:DOG:212:IDIRECT")
  field(LNK6, "XCOR:DOG:212:IACTPOL_CHECK")
}

record(calc, "XCOR:DOG:212:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:DOG:212:IDES")
  field(INPB, "XCOR:DOG:212:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(calc, "XCOR:DOG:212:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "XCOR:DOG:212:IDIFF")
  field(PREC, "9")
}

record(calc, "XCOR:DOG:212:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:DOG:212:IDIFF")
  field(INPB, "XCOR:DOG:212:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "XCOR:DOG:212:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "XCOR:DOG:212:IMIN")
  field(INPB,   "XCOR:DOG:212:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "XCOR:DOG:212:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "XCOR:DOG:212:IACT")
  field(INPB, "XCOR:DOG:212:IDES")
  field(INPC, "XCOR:DOG:212:ISETPT")
  field(INPD, "XCOR:DOG:212:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "XCOR:DOG:212:IADJUST PP")
}

record(bo, "XCOR:DOG:212:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "XCOR:DOG:212:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "XCOR:DOG:212:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "XCOR:DOG:212:IACT")
  field(FLNK, "XCOR:DOG:212:IACTPOL")
}
record(bo, "XCOR:DOG:212:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:DOG:212:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"XCOR:DOG:212:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:DOG:212:IDELTAS and the\n  XCOR:DOG:212:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"XCOR:DOG:212:IACT: \n  Get copy of XCOR:DOG:212:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"XCOR:DOG:212:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"XCOR:DOG:212:IDES:\n  Contains raw value calculated by \nXCOR:DOG:212:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nXCOR:DOG:212:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"XCOR:DOG:212:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  XCOR:DOG:212:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               XCOR:DOG:212:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"XCOR:DOG:212:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by XCOR:DOG:212:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, XCOR:DOG:212:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  XCOR:DOG:212:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "XCOR:DOG:212:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:212:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:DOG:212:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:DOG:212:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:DOG:212:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "XCOR:DOG:212:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "XCOR:DOG:212:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "XCOR:DOG:212:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "XCOR:DOG:212:TRIMTYPE.RVAL")
  field(INPB,   "XCOR:DOG:212:CONFIG.RVAL")
  field(OUT,    "XCOR:DOG:212:TRIMMAXNUM PP")
}
record(longout, "XCOR:DOG:212:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "XCOR:DOG:212:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "XCOR:DOG:212:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "XCOR:DOG:212:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "XCOR:DOG:212:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "XCOR:DOG:212:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "XCOR:DOG:212:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "XCOR:DOG:212:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "XCOR:DOG:212:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "XCOR:DOG:212:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "XCOR:DOG:212:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "XCOR:DOG:212:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "XCOR:DOG:212:IMOVE")
 field(INPB, "XCOR:DOG:212:IACT")
 field(INPC, "XCOR:DOG:212:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "XCOR:DOG:212:TRIMDLYPCT")
 field(INPF, "XCOR:DOG:212:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "XCOR:DOG:212:RAMPTIME_LEFT PP")
}

record(longout, "XCOR:DOG:212:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "XCOR:DOG:212:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "XCOR:DOG:212:RAMPDONE_CALC")
}

record(calc, "XCOR:DOG:212:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "XCOR:DOG:212:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "XCOR:DOG:212:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "XCOR:DOG:212:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:DOG:212:RAMPTIME_LEFT")
 field(OUT,  "XCOR:DOG:212:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "XCOR:DOG:212:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:DOG:212:RAMPTIME_LEFT NMS")
 field(OUT,  "XCOR:DOG:212:RAMPDONE PP")
}

record(bo, "XCOR:DOG:212:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "XCOR:DOG:212:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "XCOR:DOG:212:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "XCOR:DOG:212:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:212:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "XCOR:DOG:212:DEBUG.PROC PP")
  field(LNK2, "XCOR:DOG:212:STDZCYCLENUM.PROC PP")
  field(LNK3, "XCOR:DOG:212:STDZDISABLE.PROC PP")
  field(LNK4, "XCOR:DOG:212:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "XCOR:DOG:212:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "XCOR:DOG:212:STDZIMIN NPP NMS")
  field(INPB, "XCOR:DOG:212:STDZIMAX NPP NMS")
  field(INPC, "XCOR:DOG:212:STDZIFINAL NPP NMS")
  field(INPD, "XCOR:DOG:212:STDZCYCLENUM NPP NMS")
  field(INPE, "XCOR:DOG:212:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "XCOR:DOG:212:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "XCOR:DOG:212:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "XCOR:DOG:212:STDZWF PP")
  field(OUTB, "XCOR:DOG:212:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "XCOR:DOG:212:STDZWF")
}

record(mbbo, "XCOR:DOG:212:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "XCOR:DOG:212:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "XCOR:DOG:212:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "XCOR:DOG:212:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "XCOR:DOG:212:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "XCOR:DOG:212:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "XCOR:DOG:212:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:DOG:212:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:DOG:212:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "XCOR:DOG:212:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:212:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "XCOR:DOG:212:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "XCOR:DOG:212:STDZIMIN")
}

record(ao, "XCOR:DOG:212:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "XCOR:DOG:212:STDZIMAX")
}

record(ao, "XCOR:DOG:212:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:212:STDZIFINAL")
}

record(ao, "XCOR:DOG:212:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "XCOR:DOG:212:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "XCOR:DOG:212:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "XCOR:DOG:212:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "XCOR:DOG:212:STDZIMIN CP NMS")
  field(INPB, "XCOR:DOG:212:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "XCOR:DOG:212:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "XCOR:DOG:212:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "XCOR:DOG:212:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "XCOR:DOG:212:STDZIMIN CP NMS")
  field(INPB, "XCOR:DOG:212:STDZIMAX CP NMS")
  field(INPC, "XCOR:DOG:212:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:212:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "XCOR:DOG:212:TRIMDLYPCT CP MS")
  field(INPB, "XCOR:DOG:212:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "XCOR:DOG:212:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "XCOR:DOG:212:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:212:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "XCOR:DOG:212:IDES.HOPR")
  field(INPB, "XCOR:DOG:212:STDZMINIPCT CPP NMS")
  field(INPC, "XCOR:DOG:212:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "XCOR:DOG:212:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "XCOR:DOG:212:IDES.HOPR")
  field(INPB, "XCOR:DOG:212:IDES.LOPR")
  field(INPC, "XCOR:DOG:212:STDZDIRECT.RVAL")
  field(INPD, "XCOR:DOG:212:STDZMINIDELTA")
  field(INPE, "XCOR:DOG:212:IDES")
  field(PREC, "5")
  field(FLNK, "XCOR:DOG:212:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "XCOR:DOG:212:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "XCOR:DOG:212:IDES.HOPR")
  field(INPB, "XCOR:DOG:212:IDES.LOPR")
  field(INPC, "XCOR:DOG:212:STDZDIRECT.RVAL")
  field(INPD, "XCOR:DOG:212:STDZMINIDELTA")
  field(INPE, "XCOR:DOG:212:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "XCOR:DOG:212:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "XCOR:DOG:212:IADJUST.RVAL")
  field(INPB, "XCOR:DOG:212:STDZDIRECT.RVAL")
  field(INPC, "XCOR:DOG:212:STDZOK.RVAL")
  field(INPD, "XCOR:DOG:212:STDZDISABLE.RVAL")
  field(INPE, "XCOR:DOG:212:STATE.RVAL CPP NMS")
  field(INPF, "XCOR:DOG:212:ICTRL.RVAL")
  field(INPG, "XCOR:DOG:212:STATE.SEVR")
  field(INPH, "XCOR:DOG:212:BDELTAS.M")
  field(INPI, "XCOR:DOG:212:IACT.SEVR")
  field(OUT,  "XCOR:DOG:212:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "XCOR:DOG:212:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "XCOR:DOG:212:STDZLOSTTOD.PROC")
  field(LNK2, "XCOR:DOG:212:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "XCOR:DOG:212:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:212:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:DOG:212:IACT CP")
  field(INPB, "XCOR:DOG:212:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "XCOR:DOG:212:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "XCOR:DOG:212:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:212:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:DOG:212:STDZIACTMAX")
  field(INPB, "XCOR:DOG:212:IACT")
  field(INPC, "XCOR:DOG:212:IDELTAS.I")
  field(OUT,  "XCOR:DOG:212:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "XCOR:DOG:212:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "XCOR:DOG:212:STDZOK.RVAL CP")
  field(INPB, "XCOR:DOG:212:STDZDISABLE.RVAL CP")
  field(INPC, "XCOR:DOG:212:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "XCOR:DOG:212:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "XCOR:DOG:212:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "XCOR:DOG:212:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "XCOR:DOG:212:CALBOK")
  field(INPB, "XCOR:DOG:212:CALBDISABLE")
  field(INPC, "XCOR:DOG:212:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "XCOR:DOG:212:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "XCOR:DOG:212:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "XCOR:DOG:212:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "XCOR:DOG:212:CALBSLOPE")
  field(DOL3, "XCOR:DOG:212:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "XCOR:DOG:212:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:212:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "XCOR:DOG:212:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "XCOR:DOG:212:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "XCOR:DOG:212:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "XCOR:DOG:212:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "XCOR:DOG:212:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:212:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "XCOR:DOG:212:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:212:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "XCOR:DOG:212:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "XCOR:DOG:212:IACT")
  field(INPD, "XCOR:DOG:212:DACSLOPE")
  field(INPE, "XCOR:DOG:212:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "XCOR:DOG:212:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "XCOR:DOG:212:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "2")
  field(HOPR, "2")
  field(DRVL, "-2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "XCOR:DOG:212:CALBIMAX")
}

record(ao, "XCOR:DOG:212:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "2")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:212:CALBSTEPNUM")
}

record(ao, "XCOR:DOG:212:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL, "0")
}

record(longout, "XCOR:DOG:212:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:DOG:212:CALBIDELTA")
}

record(calc, "XCOR:DOG:212:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "XCOR:DOG:212:CALBIMAX")
  field(INPB, "XCOR:DOG:212:CALBIMIN")
  field(INPC, "XCOR:DOG:212:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "XCOR:DOG:212:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:210:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:210:IACT.HOPR")
  field(INPC, "XCOR:DOG:212:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "XCOR:DOG:212:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:DOG:212:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:212:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:212:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:212:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "XCOR:DOG:212:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:212:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:212:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:212:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "XCOR:DOG:212:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:212:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:212:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:212:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:DOG:212:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:212:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:212:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "XCOR:DOG:212:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:212:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "XCOR:DOG:212:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "XCOR:DOG:212:CALBSTEPNUM")
  field(INPB, "XCOR:DOG:212:CALBIACTWF")
  field(INPC, "XCOR:DOG:212:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "XCOR:DOG:212:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "XCOR:DOG:212:STDZITOL")

  field(INPH, "XCOR:DOG:212:DACSLOPE")
  field(INPI, "XCOR:DOG:212:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "XCOR:DOG:212:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "XCOR:DOG:212:CALBSTEPNUM")
  field(INPB, "XCOR:DOG:212:CALBIACTWF")
  field(INPC, "XCOR:DOG:212:DACWF")
  field(INPF, "XCOR:DOG:212:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe XCOR:DOG:212CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "XCOR:DOG:212:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "XCOR:DOG:212:DEGAUSIMIN.PROC PP")
  field(OUTB, "XCOR:DOG:212:DEGAUSIMAX.PROC PP")
  field(OUTC, "XCOR:DOG:212:DEGAUSTYPE.PROC PP")
  field(OUTD, "XCOR:DOG:212:DEGAUSSTEP.PROC PP")
  field(OUTE, "XCOR:DOG:212:MADNAME.PROC PP")
  field(OUTF, "XCOR:DOG:212:PSTYPE.PROC PP")
  field(OUTG, "XCOR:DOG:212:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "XCOR:DOG:212:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:DOG:212:DEGAUSIMIN NPP NMS")
  field(INPB, "XCOR:DOG:212:DEGAUSIMAX NPP NMS")
  field(INPC, "XCOR:DOG:212:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "XCOR:DOG:212:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "XCOR:DOG:212:PSTYPE NPP NMS")
  field(INPG, "XCOR:DOG:212:DEBUG.RVAL NPP NMS")
  field(INPH, "XCOR:DOG:212:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "XCOR:DOG:212:DEGAUSWF PP")
  field(OUTB, "XCOR:DOG:212:DEGAUSMSG PP")
  field(OUTC, "XCOR:DOG:212:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "XCOR:DOG:212:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"XCOR:DOG:212:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "XCOR:DOG:212:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "XCOR:DOG:212:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "XCOR:DOG:212:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "XCOR:DOG:212:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "XCOR:DOG:212:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "-2")
}
record(ao, "XCOR:DOG:212:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"XCOR:DOG:212:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "XCOR:DOG:212:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"XCOR:DOG:212:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "XCOR:DOG:212:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "XCOR:DOG:212:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "XCOR:DOG:212:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "XCOR:DOG:212:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:DOG:212:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:212:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:DOG:212:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:DOG:212:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "XCOR:DOG:212:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "XCOR:DOG:212:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "XCOR:DOG:212:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "XCOR:DOG:212:DEGAUS_IMAX")
  field(INPB, "XCOR:DOG:212:ISETPT")
  field(INPC, "XCOR:DOG:212:DEGAUSTYPE.RVAL")
  field(OUT,  "XCOR:DOG:212:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "XCOR:DOG:212:DEGAUS_IMAX_UPDATE")
}
record(seq, "XCOR:DOG:212:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "XCOR:DOG:212:ISETPT")
  field(LNK1, "XCOR:DOG:212:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "XCOR:DOG:212:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:212:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "XCOR:DOG:212:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "XCOR:DOG:212:DEGAUS_IMAX")
  field(FLNK, "XCOR:DOG:212:DEGAUS_IMAXPOL")
}
record(bo, "XCOR:DOG:212:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:DOG:212:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "XCOR:DOG:212:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "XCOR:DOG:212:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "XCOR:DOG:212:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "XCOR:DOG:212:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "XCOR:DOG:212:IACT")
  field(INPB, "XCOR:DOG:212:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "XCOR:DOG:212:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "XCOR:DOG:212:IACTPOL")
}
record(bo, "XCOR:DOG:212:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"XCOR:DOG:212:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "XCOR:DOG:212:DEGAUSENABLE CP")
  field(INPB, "XCOR:DOG:212:DEGAUSOK")
  field(INPC, "XCOR:DOG:212:STATE CP")
  field(INPD, "XCOR:DOG:212:STATE.SEVR")
  field(OUT,  "XCOR:DOG:212:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "XCOR:DOG:212:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "XCOR:DOG:212:DEGAUS_STATE_CHECK")
  field(LNK1, "XCOR:DOG:212:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "XCOR:DOG:212:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "XCOR:DOG:212:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "XCOR:DOG:212:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "XCOR:DOG:212:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "XCOR:DOG:212:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:DOG:212:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "XCOR:DOG:212:STATMSG.FRSV")
  field(LNK4, "XCOR:DOG:212:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:DOG:212:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:212:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:DOG:212:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "XCOR:DOG:212:STATMSG.FRSV")
  field(LNK4, "XCOR:DOG:212:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:DOG:212:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "XCOR:DOG:212:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "XCOR:DOG:212:STATMSG.FRSV")
  field(LNK3, "XCOR:DOG:212:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "XCOR:DOG:212:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:212:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "XCOR:DOG:212:STATMSG.FRSV PP")
  field(LNK3, "XCOR:DOG:212:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "XCOR:DOG:212:FUNC") {
  field(DESC, "XCOR:DOG:212 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "XCOR:DOG:212:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:DOG:212:CTRL") {
  field(DESC, "XCOR:DOG:212 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "XCOR:DOG:212:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "XCOR:DOG:212:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "XCOR:DOG:212:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "XCOR:DOG:212:BUSY") {
  field(DESC, "XCOR:DOG:212 Ctrl Done")
  field(DOL, "XCOR:DOG:212:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:212:SELECT")
}

record(bo, "XCOR:DOG:212:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "XCOR:DOG:212:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:DOG:212:CTRLSTATE") {
  field(DESC, "XCOR:DOG:212 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("XCOR:DOG:212:CTRL",20,20,0,0,"XCOR:DOG:212:CTRL")
#! Field("XCOR:DOG:212:CTRL.OUT",16777215,1,"XCOR:DOG:212:CTRL.OUT")
#! Link("XCOR:DOG:212:CTRL.OUT","XCOR:DOG:212:SELECTEN.A")
#! Field("XCOR:DOG:212:CTRL.VAL",16777215,1,"XCOR:DOG:212:CTRL.VAL")
#! Record("XCOR:DOG:212:SELECTEN",321,381,0,0,"XCOR:DOG:212:SELECTEN")
#! Field("XCOR:DOG:212:SELECTEN.A",16777215,0,"XCOR:DOG:212:SELECTEN.A")
#! Field("XCOR:DOG:212:SELECTEN.FLNK",16777215,1,"XCOR:DOG:212:SELECTEN.FLNK")
#! Link("XCOR:DOG:212:SELECTEN.FLNK","XCOR:DOG:212:BUSY")
#! Field("XCOR:DOG:212:SELECTEN.VAL",16777215,1,"XCOR:DOG:212:SELECTEN.VAL")
#! Record("XCOR:DOG:212:BUSY",623,274,0,0,"XCOR:DOG:212:BUSY")
#! Field("XCOR:DOG:212:BUSY.DOL",16777215,0,"XCOR:DOG:212:BUSY.DOL")
#! Link("XCOR:DOG:212:BUSY.DOL","XCOR:DOG:212:SELECTEN.VAL")
#! Field("XCOR:DOG:212:BUSY.FLNK",16777215,1,"XCOR:DOG:212:BUSY.FLNK")
#! Link("XCOR:DOG:212:BUSY.FLNK","XCOR:DOG:212:SELECT")
#! Record("XCOR:DOG:212:SELECT",669,508,0,1,"XCOR:DOG:212:SELECT")
#! Record("XCOR:DOG:212:FUNC",940,120,0,0,"XCOR:DOG:212:FUNC")
#! Field("XCOR:DOG:212:FUNC.OUT",16777215,0,"XCOR:DOG:212:FUNC.OUT")
#! Link("XCOR:DOG:212:FUNC.OUT","XCOR:DOG:212:CTRL.VAL")
#! Record("XCOR:DOG:212:ABORT",193,41,0,0,"XCOR:DOG:212:ABORT")
#! Record("XCOR:DOG:212:CTRLSTATE",369,34,0,0,"XCOR:DOG:212:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"XCOR:DOG:212:SELECT is used for Multi-device selection.\nIt is enabled when associated XCOR:DOG:212:CTRL is \"0\" (DONE).\nIt is disabled when associated XCOR:DOG:212:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"XCOR:DOG:212:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "XCOR:DOG:212:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "XCOR:DOG:212:BCTRL.SEVR")
  field(OUT,  "XCOR:DOG:212:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "XCOR:DOG:212:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:DOG:212:BACT")
  field(INPB, "XCOR:DOG:212:POLYCOEF")
  field(INPC, "XCOR:DOG:212:POLYCOEF.A")
  field(INPD, "XCOR:DOG:212:POLYCOEF.B")
  field(INPE, "XCOR:DOG:212:IACT MS")
  field(INPF, "XCOR:DOG:212:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
  field(FLNK, "XCOR:DOG:212:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "XCOR:DOG:212:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:DOG:212:BDES")
  field(INPB, "XCOR:DOG:212:TRIMBTOL")
  field(INPC, "XCOR:DOG:212:TRIMBTOLR")
  field(INPD, "XCOR:DOG:212:CHCKBTOL")
  field(INPE, "XCOR:DOG:212:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "XCOR:DOG:212:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "XCOR:DOG:212:MPSBTOL")
  field(INPQ, "XCOR:DOG:212:MPSBTOLR")
  field(FLNK, "XCOR:DOG:212:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "XCOR:DOG:212:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "XCOR:DOG:212:BDES")
  field(INPB, "XCOR:DOG:212:BDELTAS.I")
  field(INPG, "XCOR:DOG:212:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "XCOR:DOG:212:BCON.HIGH")
  field(OUTB, "XCOR:DOG:212:BCON.LOW")
  field(OUTC, "XCOR:DOG:212:BCON.HIHI")
  field(OUTD, "XCOR:DOG:212:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:212:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "XCOR:DOG:212:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:DOG:212:BDIFF")
  field(LNK2, "XCOR:DOG:212:BADIFF")
  field(LNK3, "XCOR:DOG:212:BRATIO")
  field(LNK4, "XCOR:DOG:212:MPSLIMITS")
  field(LNK5, "XCOR:DOG:212:I2BSTATUS")
  field(LNK6, "XCOR:DOG:212:IACTFO.PROC")
}

record(calc, "XCOR:DOG:212:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:DOG:212:BDES")
  field(INPB, "XCOR:DOG:212:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "XCOR:DOG:212:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "XCOR:DOG:212:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "XCOR:DOG:212:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:DOG:212:BDIFF")
  field(INPB, "XCOR:DOG:212:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "XCOR:DOG:212:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "XCOR:DOG:212:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "XCOR:DOG:212:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:DOG:212:BMON")
  field(INPB, "XCOR:DOG:212:POLYCOEF")
  field(INPC, "XCOR:DOG:212:POLYCOEF.A")
  field(INPD, "XCOR:DOG:212:POLYCOEF.B")
  field(INPE, "XCOR:DOG:212:IMON MS")
  field(INPF, "XCOR:DOG:212:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:210:BDES CP
record(ao,  "XCOR:DOG:212:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.02098636")
   field(DRVL, "-0.02098636")
   field(HOPR, "0.02098636")
   field(LOPR, "-0.02098636")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "XCOR:DOG:212:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "XCOR:DOG:212:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:212:POLYCOEF")
  field(INPC, "XCOR:DOG:212:POLYCOEF.A")
  field(INPD, "XCOR:DOG:212:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "XCOR:DOG:212:BDES.DRVH")
  field(INPF, "XCOR:DOG:212:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:212:IDES")
}
record(sub, "XCOR:DOG:212:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:212:POLYCOEF")
  field(INPC, "XCOR:DOG:212:POLYCOEF.A")
  field(INPD, "XCOR:DOG:212:POLYCOEF.B")
  field(INPE, "XCOR:DOG:212:BDES.DRVH")
  field(INPF, "XCOR:DOG:212:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "XCOR:DOG:212:INOM")
}

record(sub, "XCOR:DOG:212:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:212:BDES.VAL")
  field(INPB, "XCOR:DOG:212:BDES.DRVH")
  field(INPC, "XCOR:DOG:212:BDES.DRVL")
  field(INPD, "XCOR:DOG:212:BDELTAS.I")
  field(INPE, "XCOR:DOG:212:BDELTAS.J")
  field(INPG, "XCOR:DOG:212:STATE")
  field(INPH, "XCOR:DOG:212:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:DOG:212:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:212:BDES.VAL")
  field(INPB, "XCOR:DOG:212:BDES.DRVH")
  field(INPC, "XCOR:DOG:212:BDES.DRVL")
  field(INPD, "XCOR:DOG:212:BDELTAS.K")
  field(INPE, "XCOR:DOG:212:BDELTAS.L")
  field(INPG, "XCOR:DOG:212:STATE")
  field(INPH, "XCOR:DOG:212:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:DOG:212:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "XCOR:DOG:212:BLIMITS")
  field(LNK1, "XCOR:DOG:212:BACTLIMITS.F PP")
  field(DOL2, "XCOR:DOG:212:BACTLIMITS.I")
  field(LNK2, "XCOR:DOG:212:BACT.HIGH")
  field(DOL3, "XCOR:DOG:212:BACTLIMITS.J")
  field(LNK3, "XCOR:DOG:212:BACT.LOW")
  field(DOL4, "XCOR:DOG:212:BACTLIMITS.K")
  field(LNK4, "XCOR:DOG:212:BACT.HIHI")
  field(DOL5, "XCOR:DOG:212:BACTLIMITS.L")
  field(LNK5, "XCOR:DOG:212:BACT.LOLO")
  field(DOL6, "XCOR:DOG:212:BLIMITS")
  field(LNK6, "XCOR:DOG:212:BMONLIMITS.F PP")
  field(DOL7, "XCOR:DOG:212:BMONLIMITS.I")
  field(LNK7, "XCOR:DOG:212:BMON.HIGH")
  field(DOL8, "XCOR:DOG:212:BMONLIMITS.J")
  field(LNK8, "XCOR:DOG:212:BMON.LOW")
  field(DOL9, "XCOR:DOG:212:BMONLIMITS.K")
  field(LNK9, "XCOR:DOG:212:BMON.HIHI")
  field(DOLA, "XCOR:DOG:212:BMONLIMITS.L")
  field(LNKA, "XCOR:DOG:212:BMON.LOLO")
  field(FLNK, "XCOR:DOG:212:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "XCOR:DOG:212:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "XCOR:DOG:212:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "XCOR:DOG:212:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:212:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "XCOR:DOG:212:BCTRL.VAL")
  field(LNK2, "XCOR:DOG:212:BDES PP")

  field(DOL3, "1")
  field(LNK3, "XCOR:DOG:212:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "XCOR:DOG:212:CHECKSTDZLOST.PROC PP")

  field(DOL5, "XCOR:DOG:212:BCTRL.VAL")
  field(LNK5, "XCOR:DOG:212:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "XCOR:DOG:212:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "XCOR:DOG:212:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:212:POLYCOEF")
  field(INPC, "XCOR:DOG:212:POLYCOEF.A")
  field(INPD, "XCOR:DOG:212:POLYCOEF.B")
  field(INPE, "XCOR:DOG:212:BDES.DRVH")
  field(INPF, "XCOR:DOG:212:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:212:ISETPT")
}

record(ao, "XCOR:DOG:212:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "XCOR:DOG:212:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "XCDOG7")
}

record(ai, "XCOR:DOG:212:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "729.333373")
}

record(ao, "XCOR:DOG:212:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(FLNK, "XCOR:DOG:212:BSTEP")
}

record(ao, "XCOR:DOG:212:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(FLNK, "XCOR:DOG:212:BSTEP")
}

record(ao, "XCOR:DOG:212:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by XCOR:DOG:212:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "XCOR:DOG:212:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "XCOR:DOG:212:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "XCOR:DOG:212:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:212:POLYCOEF")
  field(INPC, "XCOR:DOG:212:POLYCOEF.A")
  field(INPD, "XCOR:DOG:212:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "XCOR:DOG:212:BCON.DRVH")
  field(INPF, "XCOR:DOG:212:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:212:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "XCOR:DOG:212:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "XCOR:DOG:212:BMAX")
  field(INPB, "XCOR:DOG:212:BMIN")
  field(INPC, "XCOR:DOG:212:BMIN.SEVR")
  field(INPD, "XCOR:DOG:212:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"XCOR:DOG:212:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "XCOR:DOG:212:ONLINE CP")
  field(OUT,  "XCOR:DOG:212:BCTRLDISABLEFOUT PP")
}

record(fanout, "XCOR:DOG:212:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "XCOR:DOG:212:BCTRLDISABLECALC")
  field(LNK1, "XCOR:DOG:212:BCTRLDISABLE")
  field(LNK2, "XCOR:DOG:212:BCTRLENABLE")
}

record(stringout, "XCOR:DOG:212:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:DOG:212:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "XCOR:DOG:212:BCTRLDISV_UPDATE")
}

record(stringout, "XCOR:DOG:212:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:DOG:212:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "XCOR:DOG:212:BCTRLDISV_UPDATE")
}

record(calcout, "XCOR:DOG:212:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "XCOR:DOG:212:ONLINE")
  field(OUT,  "XCOR:DOG:212:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"XCOR:DOG:212:BACT and MON\n  are processed via links from \n  XCOR:DOG:212:IACT (device raw value readback 1)\n  and\n  XCOR:DOG:212:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from XCOR:DOG:212:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = XCOR:DOG:212:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"XCOR:DOG:212:BDES\n  is processed when set by CA users or \n  XCOR:DOG:212:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"XCOR:DOG:212:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  XCOR:DOG:212:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (XCOR:DOG:212:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"XCOR:DOG:212:B*LIMITS and XCOR:DOG:212:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:DOG:212:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"XCOR:DOG:212:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"XCOR:DOG:212:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "XCOR:DOG:212:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:212:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "XCOR:DOG:212:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "XCOR:DOG:212:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:212:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:212:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:212:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "XCOR:DOG:212:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "XCOR:DOG:212:MPSLIMITS.E PP")
}

record(aSub, "XCOR:DOG:212:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "XCOR:DOG:212:MPS.RVAL")
  field(INPB, "XCOR:DOG:212:BADIFF")
  field(INPC, "XCOR:DOG:212:BDELTAS.N")
  field(INPD, "XCOR:DOG:212:BACT")
  field(INPE, "XCOR:DOG:212:MPSBITMASK.RVAL")
  field(INPF, "XCOR:DOG:212:MPSBLLIM")
  field(INPG, "XCOR:DOG:212:MPSBMIN")
  field(INPH, "XCOR:DOG:212:MPSBMAX")
  field(INPI, "XCOR:DOG:212:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "XCOR:DOG:212:INTOL.RVAL PP")
  field(OUTB, "XCOR:DOG:212:INTOL_BMIN.RVAL PP")
  field(OUTC, "XCOR:DOG:212:INTOL_BRANGE.RVAL PP")
  field(OUTD, "XCOR:DOG:212:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "XCOR:DOG:212:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:212:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:212:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:212:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:212:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:212:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:212:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:212:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "XCOR:DOG:212:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "XCOR:DOG:212:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:DOG:212:CHCKBTOL")
  field(INPB, "XCOR:DOG:212:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "XCOR:DOG:212:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "XCOR:DOG:212:CHCKBTOL")
  field(FLNK, "XCOR:DOG:212:CHCKITOL")
}

record(calc, "XCOR:DOG:212:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "XCOR:DOG:212:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "XCOR:DOG:212:BDES.HOPR")
  field(INPB, "XCOR:DOG:212:STABILITY")
  field(INPC, "XCOR:DOG:212:BDES.LOPR")
}

record(longout, "XCOR:DOG:212:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "XCOR:DOG:212:CHCKBTOL")
}

record(calc, "XCOR:DOG:212:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:DOG:212:POLYCOEF.B")
  field(INPB, "XCOR:DOG:212:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "XCOR:DOG:212:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "XCOR:DOG:212:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "XCOR:DOG:212:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "XCOR:DOG:212:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "XCOR:DOG:212:PAUGO")  
}

record(fanout, "XCOR:DOG:212:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "XCOR:DOG:212:PAUSTOP")
  field(LNK2, "XCOR:DOG:212:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "XCOR:DOG:212:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "XCOR:DOG:212:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:210:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:210:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "XCOR:DOG:212:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "XCOR:DOG:212:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:210:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:210:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "XCOR:DOG:212:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:210:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:DOG:212:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "XCOR:DOG:212:PSTYPE.RVAL")
  field(INPC, "XCOR:DOG:212:TURNEDOFF.RVAL")
  field(INPD, "XCOR:DOG:212:CONFIG.RVAL")
  field(INPE, "XCOR:DOG:212:PSCATEGORY.RVAL")
  field(INPF, "XCOR:DOG:212:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "XCOR:DOG:212:AUTOCTRL.RVAL")
  field(INPJ, "XCOR:DOG:212:OUTOFSERVICE.RVAL")
  field(INPL, "XCOR:DOG:212:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "XCOR:DOG:212:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "XCOR:DOG:212:PAU")
  field(INPP, "XCOR:DOG:212:CALBDISABLE.RVAL")
  field(INPQ, "XCOR:DOG:212:PTRBDISABLE.RVAL")
  field(INPR, "XCOR:DOG:212:TRIMDISABLE.RVAL")
  field(INPS, "XCOR:DOG:212:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "XCOR:DOG:212:FBCK")
  field(INPU, "XCOR:DOG:212:TRIMTYPE.RVAL")
  field(INPV, "XCOR:DOG:212:STDZDIRECT.RVAL")
  field(INPW, "XCOR:DOG:212:DEGAUSENABLE.RVAL")
  field(FLNK, "XCOR:DOG:212:HSTA")
}

record(longin, "XCOR:DOG:212:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "XCOR:DOG:212:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "XCOR:DOG:212:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "XCOR:DOG:212:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "XCOR:DOG:212:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:212:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:212:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:212:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by XCOR:DOG:212:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses XCOR:DOG:212:FBCK.
# This PV should be replaced by XCOR:DOG:212:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "XCOR:DOG:212:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "XCOR:DOG:212:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:DOG:212:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:212:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"XCOR:DOG:212:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "XCOR:DOG:212:OUTOFSERVICE NPP NMS")
  field(OUT,  "XCOR:DOG:212:ONLINE PP")
}
record(bo, "XCOR:DOG:212:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "XCOR:DOG:212:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:DOG:212:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "XCOR:DOG:212:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "XCOR:DOG:212:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "XCOR:DOG:212:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "XCOR:DOG:212:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "XCOR:DOG:212:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "XCOR:DOG:212:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:212:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:212:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:212:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "XCOR:DOG:212:TRIMTYPE")
}

record(stringout, "XCOR:DOG:212:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "XCOR:DOG:212:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "XCOR:DOG:212:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "XCOR:DOG:212:STATE.RVAL")
  field(INPB, "XCOR:DOG:212:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:DOG:212:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:DOG:212:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "XCOR:DOG:212:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "XCOR:DOG:212:STATE.RVAL")
  field(INPB, "XCOR:DOG:212:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:DOG:212:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:DOG:212:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "XCOR:DOG:212:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "XCOR:DOG:212:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "XCOR:DOG:212:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "XCOR:DOG:212:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "XCOR:DOG:212:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"XCOR:DOG:212:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("XCOR:DOG:212:TURNEDOFF",3140,1907,0,1,"XCOR:DOG:212:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:DOG:212:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "XCOR:DOG:212:BACT.STAT")
  field(INPB, "XCOR:DOG:212:BDES.STAT")
  field(INPC, "XCOR:DOG:212:IRIPL.STAT")
  field(INPD, "MCOR:EXT:210:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:210:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "XCOR:DOG:212:BACT.SEVR")
  field(INPH, "XCOR:DOG:212:BDES.SEVR")
  field(INPI, "XCOR:DOG:212:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:210:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:210:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "XCOR:DOG:212:STATE.RVAL")
  field(INPN, "XCOR:DOG:212:STDZOK")
  field(INPO, "XCOR:DOG:212:CALBOK")
  field(INPP, "XCOR:DOG:212:OUTOFSERVICE.RVAL")
  field(INPQ, "XCOR:DOG:212:CONFIG.RVAL")
  field(INPR, "XCOR:DOG:212:HSTA")
  field(INPS, "XCOR:DOG:212:CTRL.RVAL")
  field(INPT, "XCOR:DOG:212:DEGAUSOK") 
  field(INPV, "XCOR:DOG:212:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:212:STAT")
}

record(longout, "XCOR:DOG:212:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "XCOR:DOG:212:STATCTRLSUB")
  field(DOL, "XCOR:DOG:212:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "XCOR:DOG:212:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "XCOR:DOG:212:STAT")
  field(INPB, "XCOR:DOG:212:HSTA")
  field(INPD, "XCOR:DOG:212:ONOFFCTRL.RVAL")
  field(FLNK, "XCOR:DOG:212:STATMSG")
}

record(mbbo, "XCOR:DOG:212:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:DOG:212:UNAVAILGO")
  field(DOL, "XCOR:DOG:212:STATCTRLSUB.W")
}

record(seq, "XCOR:DOG:212:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "XCOR:DOG:212:STATSUB.U")
  field(LNK1, "XCOR:DOG:212:UNAVAIL PP")
}

record(stringout, "XCOR:DOG:212:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"XCOR:DOG:212:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - XCOR:DOG:212:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - XCOR:DOG:212:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"XCOR:DOG:212STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - XCOR:DOG:212:STATUS\nC - XCOR:DOG:212:ON\nD - XCOR:DOG:212:STDZOK\nE - XCOR:DOG:212:CALBOK\nF - XCOR:DOG:212:BACTDRIFT (future)\nG -\nH- XCOR:DOG:212:DACSTATUS\nI -XCOR:DOG:212:ADCSTATUS\nJ - XCOR:DOG:212:BACTSTATUS\nK - XCOR:DOG:212:BDESSTATUS\nL - XCOR:DOG:212:RIPLSTATUS\n\nOutput:\nP - XCOR:DOG:212:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "XCOR:DOG:212:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "XCOR:DOG:212:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "XCOR:DOG:212:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "XCOR:DOG:212:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "YCOR:DOG:227:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:211:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:DOG:227:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "YCOR:DOG:227:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:211:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "YCOR:DOG:227:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "2")
  field(LOLO, "-2")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "YCOR:DOG:227:BDELTAS")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "YCOR:DOG:227:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "YCOR:DOG:227:ICTRL PP")
}

# This record is processed by YCOR:DOG:227:ICON")
# Note: we are not setting alarms here.
record(ao, "YCOR:DOG:227:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "YCOR:DOG:227:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:227:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "YCOR:DOG:227:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(ao, "YCOR:DOG:227:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(FLNK, "YCOR:DOG:227:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "YCOR:DOG:227:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "YCOR:DOG:227:ISETPT.OMSL")

  field(DOL2, "YCOR:DOG:227:ICTRL")
  field(LNK2, "YCOR:DOG:227:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "YCOR:DOG:227:ISETPT.OMSL")
}

record(ao, "YCOR:DOG:227:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:227:IMIN")
}

record(ao, "YCOR:DOG:227:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(VAL,  "-2")
  field(FLNK, "YCOR:DOG:227:IRANGE")
}

record(sel, "YCOR:DOG:227:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(NVL,  "YCOR:DOG:227:BACT.SEVR")
  field(INPA, "YCOR:DOG:227:IACT NPP MS")
  field(INPB, "YCOR:DOG:227:IACTPREVOK NPP MS")
  field(INPC, "YCOR:DOG:227:IACTPREVOK NPP MS")
  field(INPD, "YCOR:DOG:227:IACTPREVOK NPP MS")
}

record(sub, "YCOR:DOG:227:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:227:IDES")
  field(INPB, "YCOR:DOG:227:ISETPT.DRVH")
  field(INPC, "YCOR:DOG:227:ISETPT.DRVL")
  field(INPD, "YCOR:DOG:227:IDELTAS.I")
  field(INPE, "YCOR:DOG:227:IDELTAS.J")
  field(INPG, "YCOR:DOG:227:STATE")
  field(INPH, "YCOR:DOG:227:HSTA")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:DOG:227:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:227:IDES")
  field(INPB, "YCOR:DOG:227:ISETPT.DRVH")
  field(INPC, "YCOR:DOG:227:ISETPT.DRVL")
  field(INPD, "YCOR:DOG:227:IDELTAS.K")
  field(INPE, "YCOR:DOG:227:IDELTAS.L")
  field(INPG, "YCOR:DOG:227:STATE")
  field(INPH, "YCOR:DOG:227:HSTA")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:DOG:227:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "YCOR:DOG:227:BLIMITS")
  field(LNK1, "YCOR:DOG:227:IACTLIMITS.F PP")
  field(DOL2, "YCOR:DOG:227:IACTLIMITS.I")
  field(LNK2, "YCOR:DOG:227:IACT.HIGH")
  field(DOL3, "YCOR:DOG:227:IACTLIMITS.J")
  field(LNK3, "YCOR:DOG:227:IACT.LOW")
  field(DOL4, "YCOR:DOG:227:IACTLIMITS.K")
  field(LNK4, "YCOR:DOG:227:IACT.HIHI")
  field(DOL5, "YCOR:DOG:227:IACTLIMITS.L")
  field(LNK5, "YCOR:DOG:227:IACT.LOLO")
  field(DOL6, "YCOR:DOG:227:BLIMITS")
  field(LNK6, "YCOR:DOG:227:IMONLIMITS.F PP")
  field(DOL7, "YCOR:DOG:227:IMONLIMITS.I")
  field(LNK7, "YCOR:DOG:227:IMON.HIGH")
  field(DOL8, "YCOR:DOG:227:IMONLIMITS.J")
  field(LNK8, "YCOR:DOG:227:IMON.LOW")
  field(DOL9, "YCOR:DOG:227:IMONLIMITS.K")
  field(LNK9, "YCOR:DOG:227:IMON.HIHI")
  field(DOLA, "YCOR:DOG:227:IMONLIMITS.L")
  field(LNKA, "YCOR:DOG:227:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "YCOR:DOG:227:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "YCOR:DOG:227:TRIMBTOL")
  field(INPE, "YCOR:DOG:227:CHCKBTOL")
  field(INPF, "YCOR:DOG:227:BDELTAS.K")
  field(INPG, "YCOR:DOG:227:BDELTAS.L")
  field(INPH, "YCOR:DOG:227:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "YCOR:DOG:227:STDZITOLR")
  field(INPC, "YCOR:DOG:227:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:211:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "YCOR:DOG:227:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:211:RESET PP
#
record(bo, "YCOR:DOG:227:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:211:RESET PP")
}

record(bo, "YCOR:DOG:227:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:211:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "YCOR:DOG:227:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "YCOR:DOG:227:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:211:IRAMPRATE PP")
  field(FLNK, "YCOR:DOG:227:STDZDLY")
}


record(ao, "YCOR:DOG:227:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:211:ISETPT PP")
  field(DOL, "YCOR:DOG:227:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "YCOR:DOG:227:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:211:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:DOG:227:BMON")
}

record(ao, "YCOR:DOG:227:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:211:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "YCOR:DOG:227:IRIPLOK")
}

record(sub, "YCOR:DOG:227:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "YCOR:DOG:227:IRIPL.VAL")
  field(INPB, "YCOR:DOG:227:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:DOG:227:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:DOG:227:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "YCOR:DOG:227:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:211:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "YCOR:DOG:227:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:211:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "YCOR:DOG:227:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:DOG:227:IACTPREVOK")
  field(LNK2, "YCOR:DOG:227:IDIFF")
  field(LNK3, "YCOR:DOG:227:IADIFF")
  field(LNK4, "YCOR:DOG:227:IRATIO")
  field(LNK5, "YCOR:DOG:227:IDIRECT")
  field(LNK6, "YCOR:DOG:227:IACTPOL_CHECK")
}

record(calc, "YCOR:DOG:227:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:DOG:227:IDES")
  field(INPB, "YCOR:DOG:227:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(calc, "YCOR:DOG:227:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "YCOR:DOG:227:IDIFF")
  field(PREC, "9")
}

record(calc, "YCOR:DOG:227:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:DOG:227:IDIFF")
  field(INPB, "YCOR:DOG:227:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "YCOR:DOG:227:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "YCOR:DOG:227:IMIN")
  field(INPB,   "YCOR:DOG:227:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "YCOR:DOG:227:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "YCOR:DOG:227:IACT")
  field(INPB, "YCOR:DOG:227:IDES")
  field(INPC, "YCOR:DOG:227:ISETPT")
  field(INPD, "YCOR:DOG:227:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "YCOR:DOG:227:IADJUST PP")
}

record(bo, "YCOR:DOG:227:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "YCOR:DOG:227:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "YCOR:DOG:227:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "YCOR:DOG:227:IACT")
  field(FLNK, "YCOR:DOG:227:IACTPOL")
}
record(bo, "YCOR:DOG:227:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:DOG:227:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"YCOR:DOG:227:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:DOG:227:IDELTAS and the\n  YCOR:DOG:227:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"YCOR:DOG:227:IACT: \n  Get copy of YCOR:DOG:227:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"YCOR:DOG:227:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"YCOR:DOG:227:IDES:\n  Contains raw value calculated by \nYCOR:DOG:227:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nYCOR:DOG:227:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"YCOR:DOG:227:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  YCOR:DOG:227:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               YCOR:DOG:227:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"YCOR:DOG:227:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by YCOR:DOG:227:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, YCOR:DOG:227:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  YCOR:DOG:227:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "YCOR:DOG:227:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:227:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:DOG:227:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:DOG:227:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:DOG:227:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "YCOR:DOG:227:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "YCOR:DOG:227:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "YCOR:DOG:227:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "YCOR:DOG:227:TRIMTYPE.RVAL")
  field(INPB,   "YCOR:DOG:227:CONFIG.RVAL")
  field(OUT,    "YCOR:DOG:227:TRIMMAXNUM PP")
}
record(longout, "YCOR:DOG:227:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "YCOR:DOG:227:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "YCOR:DOG:227:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "YCOR:DOG:227:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "YCOR:DOG:227:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "YCOR:DOG:227:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "YCOR:DOG:227:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "YCOR:DOG:227:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "YCOR:DOG:227:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "YCOR:DOG:227:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "YCOR:DOG:227:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "YCOR:DOG:227:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "YCOR:DOG:227:IMOVE")
 field(INPB, "YCOR:DOG:227:IACT")
 field(INPC, "YCOR:DOG:227:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "YCOR:DOG:227:TRIMDLYPCT")
 field(INPF, "YCOR:DOG:227:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "YCOR:DOG:227:RAMPTIME_LEFT PP")
}

record(longout, "YCOR:DOG:227:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "YCOR:DOG:227:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "YCOR:DOG:227:RAMPDONE_CALC")
}

record(calc, "YCOR:DOG:227:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "YCOR:DOG:227:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "YCOR:DOG:227:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "YCOR:DOG:227:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:DOG:227:RAMPTIME_LEFT")
 field(OUT,  "YCOR:DOG:227:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "YCOR:DOG:227:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:DOG:227:RAMPTIME_LEFT NMS")
 field(OUT,  "YCOR:DOG:227:RAMPDONE PP")
}

record(bo, "YCOR:DOG:227:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "YCOR:DOG:227:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "YCOR:DOG:227:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "YCOR:DOG:227:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:227:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "YCOR:DOG:227:DEBUG.PROC PP")
  field(LNK2, "YCOR:DOG:227:STDZCYCLENUM.PROC PP")
  field(LNK3, "YCOR:DOG:227:STDZDISABLE.PROC PP")
  field(LNK4, "YCOR:DOG:227:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "YCOR:DOG:227:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "YCOR:DOG:227:STDZIMIN NPP NMS")
  field(INPB, "YCOR:DOG:227:STDZIMAX NPP NMS")
  field(INPC, "YCOR:DOG:227:STDZIFINAL NPP NMS")
  field(INPD, "YCOR:DOG:227:STDZCYCLENUM NPP NMS")
  field(INPE, "YCOR:DOG:227:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "YCOR:DOG:227:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "YCOR:DOG:227:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "YCOR:DOG:227:STDZWF PP")
  field(OUTB, "YCOR:DOG:227:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "YCOR:DOG:227:STDZWF")
}

record(mbbo, "YCOR:DOG:227:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "YCOR:DOG:227:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "YCOR:DOG:227:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "YCOR:DOG:227:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "YCOR:DOG:227:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "YCOR:DOG:227:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "YCOR:DOG:227:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:DOG:227:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:DOG:227:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "YCOR:DOG:227:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:227:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "YCOR:DOG:227:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "YCOR:DOG:227:STDZIMIN")
}

record(ao, "YCOR:DOG:227:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "YCOR:DOG:227:STDZIMAX")
}

record(ao, "YCOR:DOG:227:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:227:STDZIFINAL")
}

record(ao, "YCOR:DOG:227:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "YCOR:DOG:227:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "YCOR:DOG:227:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "YCOR:DOG:227:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "YCOR:DOG:227:STDZIMIN CP NMS")
  field(INPB, "YCOR:DOG:227:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "YCOR:DOG:227:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "YCOR:DOG:227:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "YCOR:DOG:227:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "YCOR:DOG:227:STDZIMIN CP NMS")
  field(INPB, "YCOR:DOG:227:STDZIMAX CP NMS")
  field(INPC, "YCOR:DOG:227:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:227:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "YCOR:DOG:227:TRIMDLYPCT CP MS")
  field(INPB, "YCOR:DOG:227:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "YCOR:DOG:227:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "YCOR:DOG:227:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:227:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "YCOR:DOG:227:IDES.HOPR")
  field(INPB, "YCOR:DOG:227:STDZMINIPCT CPP NMS")
  field(INPC, "YCOR:DOG:227:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "YCOR:DOG:227:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "YCOR:DOG:227:IDES.HOPR")
  field(INPB, "YCOR:DOG:227:IDES.LOPR")
  field(INPC, "YCOR:DOG:227:STDZDIRECT.RVAL")
  field(INPD, "YCOR:DOG:227:STDZMINIDELTA")
  field(INPE, "YCOR:DOG:227:IDES")
  field(PREC, "5")
  field(FLNK, "YCOR:DOG:227:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "YCOR:DOG:227:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "YCOR:DOG:227:IDES.HOPR")
  field(INPB, "YCOR:DOG:227:IDES.LOPR")
  field(INPC, "YCOR:DOG:227:STDZDIRECT.RVAL")
  field(INPD, "YCOR:DOG:227:STDZMINIDELTA")
  field(INPE, "YCOR:DOG:227:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "YCOR:DOG:227:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "YCOR:DOG:227:IADJUST.RVAL")
  field(INPB, "YCOR:DOG:227:STDZDIRECT.RVAL")
  field(INPC, "YCOR:DOG:227:STDZOK.RVAL")
  field(INPD, "YCOR:DOG:227:STDZDISABLE.RVAL")
  field(INPE, "YCOR:DOG:227:STATE.RVAL CPP NMS")
  field(INPF, "YCOR:DOG:227:ICTRL.RVAL")
  field(INPG, "YCOR:DOG:227:STATE.SEVR")
  field(INPH, "YCOR:DOG:227:BDELTAS.M")
  field(INPI, "YCOR:DOG:227:IACT.SEVR")
  field(OUT,  "YCOR:DOG:227:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "YCOR:DOG:227:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "YCOR:DOG:227:STDZLOSTTOD.PROC")
  field(LNK2, "YCOR:DOG:227:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "YCOR:DOG:227:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:227:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:DOG:227:IACT CP")
  field(INPB, "YCOR:DOG:227:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "YCOR:DOG:227:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "YCOR:DOG:227:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:227:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:DOG:227:STDZIACTMAX")
  field(INPB, "YCOR:DOG:227:IACT")
  field(INPC, "YCOR:DOG:227:IDELTAS.I")
  field(OUT,  "YCOR:DOG:227:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "YCOR:DOG:227:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "YCOR:DOG:227:STDZOK.RVAL CP")
  field(INPB, "YCOR:DOG:227:STDZDISABLE.RVAL CP")
  field(INPC, "YCOR:DOG:227:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "YCOR:DOG:227:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "YCOR:DOG:227:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "YCOR:DOG:227:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "YCOR:DOG:227:CALBOK")
  field(INPB, "YCOR:DOG:227:CALBDISABLE")
  field(INPC, "YCOR:DOG:227:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "YCOR:DOG:227:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "YCOR:DOG:227:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "YCOR:DOG:227:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "YCOR:DOG:227:CALBSLOPE")
  field(DOL3, "YCOR:DOG:227:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "YCOR:DOG:227:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:227:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "YCOR:DOG:227:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "YCOR:DOG:227:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "YCOR:DOG:227:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "YCOR:DOG:227:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "YCOR:DOG:227:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:227:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "YCOR:DOG:227:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:227:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "YCOR:DOG:227:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "YCOR:DOG:227:IACT")
  field(INPD, "YCOR:DOG:227:DACSLOPE")
  field(INPE, "YCOR:DOG:227:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "YCOR:DOG:227:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "YCOR:DOG:227:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "2")
  field(HOPR, "2")
  field(DRVL, "-2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "YCOR:DOG:227:CALBIMAX")
}

record(ao, "YCOR:DOG:227:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "2")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:227:CALBSTEPNUM")
}

record(ao, "YCOR:DOG:227:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL, "0")
}

record(longout, "YCOR:DOG:227:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:DOG:227:CALBIDELTA")
}

record(calc, "YCOR:DOG:227:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "YCOR:DOG:227:CALBIMAX")
  field(INPB, "YCOR:DOG:227:CALBIMIN")
  field(INPC, "YCOR:DOG:227:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "YCOR:DOG:227:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:211:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:211:IACT.HOPR")
  field(INPC, "YCOR:DOG:227:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "YCOR:DOG:227:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:DOG:227:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:227:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:227:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:227:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "YCOR:DOG:227:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:227:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:227:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:227:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "YCOR:DOG:227:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:227:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:227:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:227:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:DOG:227:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:227:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:227:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "YCOR:DOG:227:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:227:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "YCOR:DOG:227:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "YCOR:DOG:227:CALBSTEPNUM")
  field(INPB, "YCOR:DOG:227:CALBIACTWF")
  field(INPC, "YCOR:DOG:227:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "YCOR:DOG:227:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "YCOR:DOG:227:STDZITOL")

  field(INPH, "YCOR:DOG:227:DACSLOPE")
  field(INPI, "YCOR:DOG:227:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "YCOR:DOG:227:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "YCOR:DOG:227:CALBSTEPNUM")
  field(INPB, "YCOR:DOG:227:CALBIACTWF")
  field(INPC, "YCOR:DOG:227:DACWF")
  field(INPF, "YCOR:DOG:227:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe YCOR:DOG:227CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "YCOR:DOG:227:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "YCOR:DOG:227:DEGAUSIMIN.PROC PP")
  field(OUTB, "YCOR:DOG:227:DEGAUSIMAX.PROC PP")
  field(OUTC, "YCOR:DOG:227:DEGAUSTYPE.PROC PP")
  field(OUTD, "YCOR:DOG:227:DEGAUSSTEP.PROC PP")
  field(OUTE, "YCOR:DOG:227:MADNAME.PROC PP")
  field(OUTF, "YCOR:DOG:227:PSTYPE.PROC PP")
  field(OUTG, "YCOR:DOG:227:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "YCOR:DOG:227:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:DOG:227:DEGAUSIMIN NPP NMS")
  field(INPB, "YCOR:DOG:227:DEGAUSIMAX NPP NMS")
  field(INPC, "YCOR:DOG:227:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "YCOR:DOG:227:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "YCOR:DOG:227:PSTYPE NPP NMS")
  field(INPG, "YCOR:DOG:227:DEBUG.RVAL NPP NMS")
  field(INPH, "YCOR:DOG:227:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "YCOR:DOG:227:DEGAUSWF PP")
  field(OUTB, "YCOR:DOG:227:DEGAUSMSG PP")
  field(OUTC, "YCOR:DOG:227:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "YCOR:DOG:227:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"YCOR:DOG:227:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "YCOR:DOG:227:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "YCOR:DOG:227:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "YCOR:DOG:227:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "YCOR:DOG:227:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "YCOR:DOG:227:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "-2")
}
record(ao, "YCOR:DOG:227:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"YCOR:DOG:227:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "YCOR:DOG:227:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"YCOR:DOG:227:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "YCOR:DOG:227:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "YCOR:DOG:227:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "YCOR:DOG:227:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "YCOR:DOG:227:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:DOG:227:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:227:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:DOG:227:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:DOG:227:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "YCOR:DOG:227:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "YCOR:DOG:227:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "YCOR:DOG:227:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "YCOR:DOG:227:DEGAUS_IMAX")
  field(INPB, "YCOR:DOG:227:ISETPT")
  field(INPC, "YCOR:DOG:227:DEGAUSTYPE.RVAL")
  field(OUT,  "YCOR:DOG:227:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "YCOR:DOG:227:DEGAUS_IMAX_UPDATE")
}
record(seq, "YCOR:DOG:227:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "YCOR:DOG:227:ISETPT")
  field(LNK1, "YCOR:DOG:227:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "YCOR:DOG:227:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
  field(FLNK, "YCOR:DOG:227:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "YCOR:DOG:227:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "YCOR:DOG:227:DEGAUS_IMAX")
  field(FLNK, "YCOR:DOG:227:DEGAUS_IMAXPOL")
}
record(bo, "YCOR:DOG:227:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:DOG:227:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "YCOR:DOG:227:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "YCOR:DOG:227:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "YCOR:DOG:227:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "YCOR:DOG:227:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "YCOR:DOG:227:IACT")
  field(INPB, "YCOR:DOG:227:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "YCOR:DOG:227:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "YCOR:DOG:227:IACTPOL")
}
record(bo, "YCOR:DOG:227:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"YCOR:DOG:227:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "YCOR:DOG:227:DEGAUSENABLE CP")
  field(INPB, "YCOR:DOG:227:DEGAUSOK")
  field(INPC, "YCOR:DOG:227:STATE CP")
  field(INPD, "YCOR:DOG:227:STATE.SEVR")
  field(OUT,  "YCOR:DOG:227:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "YCOR:DOG:227:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "YCOR:DOG:227:DEGAUS_STATE_CHECK")
  field(LNK1, "YCOR:DOG:227:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "YCOR:DOG:227:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "YCOR:DOG:227:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "YCOR:DOG:227:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "YCOR:DOG:227:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "YCOR:DOG:227:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:DOG:227:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "YCOR:DOG:227:STATMSG.FRSV")
  field(LNK4, "YCOR:DOG:227:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:DOG:227:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:227:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:DOG:227:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "YCOR:DOG:227:STATMSG.FRSV")
  field(LNK4, "YCOR:DOG:227:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:DOG:227:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "YCOR:DOG:227:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "YCOR:DOG:227:STATMSG.FRSV")
  field(LNK3, "YCOR:DOG:227:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "YCOR:DOG:227:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:227:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "YCOR:DOG:227:STATMSG.FRSV PP")
  field(LNK3, "YCOR:DOG:227:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "YCOR:DOG:227:FUNC") {
  field(DESC, "YCOR:DOG:227 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "YCOR:DOG:227:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:DOG:227:CTRL") {
  field(DESC, "YCOR:DOG:227 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "YCOR:DOG:227:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "YCOR:DOG:227:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "YCOR:DOG:227:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "YCOR:DOG:227:BUSY") {
  field(DESC, "YCOR:DOG:227 Ctrl Done")
  field(DOL, "YCOR:DOG:227:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:227:SELECT")
}

record(bo, "YCOR:DOG:227:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "YCOR:DOG:227:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:DOG:227:CTRLSTATE") {
  field(DESC, "YCOR:DOG:227 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("YCOR:DOG:227:CTRL",20,20,0,0,"YCOR:DOG:227:CTRL")
#! Field("YCOR:DOG:227:CTRL.OUT",16777215,1,"YCOR:DOG:227:CTRL.OUT")
#! Link("YCOR:DOG:227:CTRL.OUT","YCOR:DOG:227:SELECTEN.A")
#! Field("YCOR:DOG:227:CTRL.VAL",16777215,1,"YCOR:DOG:227:CTRL.VAL")
#! Record("YCOR:DOG:227:SELECTEN",321,381,0,0,"YCOR:DOG:227:SELECTEN")
#! Field("YCOR:DOG:227:SELECTEN.A",16777215,0,"YCOR:DOG:227:SELECTEN.A")
#! Field("YCOR:DOG:227:SELECTEN.FLNK",16777215,1,"YCOR:DOG:227:SELECTEN.FLNK")
#! Link("YCOR:DOG:227:SELECTEN.FLNK","YCOR:DOG:227:BUSY")
#! Field("YCOR:DOG:227:SELECTEN.VAL",16777215,1,"YCOR:DOG:227:SELECTEN.VAL")
#! Record("YCOR:DOG:227:BUSY",623,274,0,0,"YCOR:DOG:227:BUSY")
#! Field("YCOR:DOG:227:BUSY.DOL",16777215,0,"YCOR:DOG:227:BUSY.DOL")
#! Link("YCOR:DOG:227:BUSY.DOL","YCOR:DOG:227:SELECTEN.VAL")
#! Field("YCOR:DOG:227:BUSY.FLNK",16777215,1,"YCOR:DOG:227:BUSY.FLNK")
#! Link("YCOR:DOG:227:BUSY.FLNK","YCOR:DOG:227:SELECT")
#! Record("YCOR:DOG:227:SELECT",669,508,0,1,"YCOR:DOG:227:SELECT")
#! Record("YCOR:DOG:227:FUNC",940,120,0,0,"YCOR:DOG:227:FUNC")
#! Field("YCOR:DOG:227:FUNC.OUT",16777215,0,"YCOR:DOG:227:FUNC.OUT")
#! Link("YCOR:DOG:227:FUNC.OUT","YCOR:DOG:227:CTRL.VAL")
#! Record("YCOR:DOG:227:ABORT",193,41,0,0,"YCOR:DOG:227:ABORT")
#! Record("YCOR:DOG:227:CTRLSTATE",369,34,0,0,"YCOR:DOG:227:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"YCOR:DOG:227:SELECT is used for Multi-device selection.\nIt is enabled when associated YCOR:DOG:227:CTRL is \"0\" (DONE).\nIt is disabled when associated YCOR:DOG:227:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"YCOR:DOG:227:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "YCOR:DOG:227:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "YCOR:DOG:227:BCTRL.SEVR")
  field(OUT,  "YCOR:DOG:227:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "YCOR:DOG:227:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:DOG:227:BACT")
  field(INPB, "YCOR:DOG:227:POLYCOEF")
  field(INPC, "YCOR:DOG:227:POLYCOEF.A")
  field(INPD, "YCOR:DOG:227:POLYCOEF.B")
  field(INPE, "YCOR:DOG:227:IACT MS")
  field(INPF, "YCOR:DOG:227:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
  field(FLNK, "YCOR:DOG:227:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "YCOR:DOG:227:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:DOG:227:BDES")
  field(INPB, "YCOR:DOG:227:TRIMBTOL")
  field(INPC, "YCOR:DOG:227:TRIMBTOLR")
  field(INPD, "YCOR:DOG:227:CHCKBTOL")
  field(INPE, "YCOR:DOG:227:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "YCOR:DOG:227:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "YCOR:DOG:227:MPSBTOL")
  field(INPQ, "YCOR:DOG:227:MPSBTOLR")
  field(FLNK, "YCOR:DOG:227:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "YCOR:DOG:227:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "YCOR:DOG:227:BDES")
  field(INPB, "YCOR:DOG:227:BDELTAS.I")
  field(INPG, "YCOR:DOG:227:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "YCOR:DOG:227:BCON.HIGH")
  field(OUTB, "YCOR:DOG:227:BCON.LOW")
  field(OUTC, "YCOR:DOG:227:BCON.HIHI")
  field(OUTD, "YCOR:DOG:227:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:227:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "YCOR:DOG:227:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:DOG:227:BDIFF")
  field(LNK2, "YCOR:DOG:227:BADIFF")
  field(LNK3, "YCOR:DOG:227:BRATIO")
  field(LNK4, "YCOR:DOG:227:MPSLIMITS")
  field(LNK5, "YCOR:DOG:227:I2BSTATUS")
  field(LNK6, "YCOR:DOG:227:IACTFO.PROC")
}

record(calc, "YCOR:DOG:227:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:DOG:227:BDES")
  field(INPB, "YCOR:DOG:227:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "YCOR:DOG:227:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "YCOR:DOG:227:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "YCOR:DOG:227:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:DOG:227:BDIFF")
  field(INPB, "YCOR:DOG:227:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "YCOR:DOG:227:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "YCOR:DOG:227:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "YCOR:DOG:227:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:DOG:227:BMON")
  field(INPB, "YCOR:DOG:227:POLYCOEF")
  field(INPC, "YCOR:DOG:227:POLYCOEF.A")
  field(INPD, "YCOR:DOG:227:POLYCOEF.B")
  field(INPE, "YCOR:DOG:227:IMON MS")
  field(INPF, "YCOR:DOG:227:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:211:BDES CP
record(ao,  "YCOR:DOG:227:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.02098636")
   field(DRVL, "-0.02098636")
   field(HOPR, "0.02098636")
   field(LOPR, "-0.02098636")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "YCOR:DOG:227:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "YCOR:DOG:227:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:227:POLYCOEF")
  field(INPC, "YCOR:DOG:227:POLYCOEF.A")
  field(INPD, "YCOR:DOG:227:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "YCOR:DOG:227:BDES.DRVH")
  field(INPF, "YCOR:DOG:227:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:227:IDES")
}
record(sub, "YCOR:DOG:227:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:227:POLYCOEF")
  field(INPC, "YCOR:DOG:227:POLYCOEF.A")
  field(INPD, "YCOR:DOG:227:POLYCOEF.B")
  field(INPE, "YCOR:DOG:227:BDES.DRVH")
  field(INPF, "YCOR:DOG:227:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "YCOR:DOG:227:INOM")
}

record(sub, "YCOR:DOG:227:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:227:BDES.VAL")
  field(INPB, "YCOR:DOG:227:BDES.DRVH")
  field(INPC, "YCOR:DOG:227:BDES.DRVL")
  field(INPD, "YCOR:DOG:227:BDELTAS.I")
  field(INPE, "YCOR:DOG:227:BDELTAS.J")
  field(INPG, "YCOR:DOG:227:STATE")
  field(INPH, "YCOR:DOG:227:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:DOG:227:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:227:BDES.VAL")
  field(INPB, "YCOR:DOG:227:BDES.DRVH")
  field(INPC, "YCOR:DOG:227:BDES.DRVL")
  field(INPD, "YCOR:DOG:227:BDELTAS.K")
  field(INPE, "YCOR:DOG:227:BDELTAS.L")
  field(INPG, "YCOR:DOG:227:STATE")
  field(INPH, "YCOR:DOG:227:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:DOG:227:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "YCOR:DOG:227:BLIMITS")
  field(LNK1, "YCOR:DOG:227:BACTLIMITS.F PP")
  field(DOL2, "YCOR:DOG:227:BACTLIMITS.I")
  field(LNK2, "YCOR:DOG:227:BACT.HIGH")
  field(DOL3, "YCOR:DOG:227:BACTLIMITS.J")
  field(LNK3, "YCOR:DOG:227:BACT.LOW")
  field(DOL4, "YCOR:DOG:227:BACTLIMITS.K")
  field(LNK4, "YCOR:DOG:227:BACT.HIHI")
  field(DOL5, "YCOR:DOG:227:BACTLIMITS.L")
  field(LNK5, "YCOR:DOG:227:BACT.LOLO")
  field(DOL6, "YCOR:DOG:227:BLIMITS")
  field(LNK6, "YCOR:DOG:227:BMONLIMITS.F PP")
  field(DOL7, "YCOR:DOG:227:BMONLIMITS.I")
  field(LNK7, "YCOR:DOG:227:BMON.HIGH")
  field(DOL8, "YCOR:DOG:227:BMONLIMITS.J")
  field(LNK8, "YCOR:DOG:227:BMON.LOW")
  field(DOL9, "YCOR:DOG:227:BMONLIMITS.K")
  field(LNK9, "YCOR:DOG:227:BMON.HIHI")
  field(DOLA, "YCOR:DOG:227:BMONLIMITS.L")
  field(LNKA, "YCOR:DOG:227:BMON.LOLO")
  field(FLNK, "YCOR:DOG:227:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "YCOR:DOG:227:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "YCOR:DOG:227:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "YCOR:DOG:227:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:227:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "YCOR:DOG:227:BCTRL.VAL")
  field(LNK2, "YCOR:DOG:227:BDES PP")

  field(DOL3, "1")
  field(LNK3, "YCOR:DOG:227:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "YCOR:DOG:227:CHECKSTDZLOST.PROC PP")

  field(DOL5, "YCOR:DOG:227:BCTRL.VAL")
  field(LNK5, "YCOR:DOG:227:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "YCOR:DOG:227:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "YCOR:DOG:227:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:227:POLYCOEF")
  field(INPC, "YCOR:DOG:227:POLYCOEF.A")
  field(INPD, "YCOR:DOG:227:POLYCOEF.B")
  field(INPE, "YCOR:DOG:227:BDES.DRVH")
  field(INPF, "YCOR:DOG:227:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:227:ISETPT")
}

record(ao, "YCOR:DOG:227:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "YCOR:DOG:227:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "YCDOG8")
}

record(ai, "YCOR:DOG:227:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "739.212345")
}

record(ao, "YCOR:DOG:227:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(FLNK, "YCOR:DOG:227:BSTEP")
}

record(ao, "YCOR:DOG:227:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(FLNK, "YCOR:DOG:227:BSTEP")
}

record(ao, "YCOR:DOG:227:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by YCOR:DOG:227:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "YCOR:DOG:227:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "YCOR:DOG:227:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "YCOR:DOG:227:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:227:POLYCOEF")
  field(INPC, "YCOR:DOG:227:POLYCOEF.A")
  field(INPD, "YCOR:DOG:227:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "YCOR:DOG:227:BCON.DRVH")
  field(INPF, "YCOR:DOG:227:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:227:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "YCOR:DOG:227:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "YCOR:DOG:227:BMAX")
  field(INPB, "YCOR:DOG:227:BMIN")
  field(INPC, "YCOR:DOG:227:BMIN.SEVR")
  field(INPD, "YCOR:DOG:227:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"YCOR:DOG:227:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "YCOR:DOG:227:ONLINE CP")
  field(OUT,  "YCOR:DOG:227:BCTRLDISABLEFOUT PP")
}

record(fanout, "YCOR:DOG:227:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "YCOR:DOG:227:BCTRLDISABLECALC")
  field(LNK1, "YCOR:DOG:227:BCTRLDISABLE")
  field(LNK2, "YCOR:DOG:227:BCTRLENABLE")
}

record(stringout, "YCOR:DOG:227:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:DOG:227:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "YCOR:DOG:227:BCTRLDISV_UPDATE")
}

record(stringout, "YCOR:DOG:227:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:DOG:227:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "YCOR:DOG:227:BCTRLDISV_UPDATE")
}

record(calcout, "YCOR:DOG:227:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "YCOR:DOG:227:ONLINE")
  field(OUT,  "YCOR:DOG:227:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"YCOR:DOG:227:BACT and MON\n  are processed via links from \n  YCOR:DOG:227:IACT (device raw value readback 1)\n  and\n  YCOR:DOG:227:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from YCOR:DOG:227:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = YCOR:DOG:227:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"YCOR:DOG:227:BDES\n  is processed when set by CA users or \n  YCOR:DOG:227:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"YCOR:DOG:227:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  YCOR:DOG:227:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (YCOR:DOG:227:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"YCOR:DOG:227:B*LIMITS and YCOR:DOG:227:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:DOG:227:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"YCOR:DOG:227:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"YCOR:DOG:227:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "YCOR:DOG:227:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:227:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "YCOR:DOG:227:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "YCOR:DOG:227:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:227:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:227:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:227:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "YCOR:DOG:227:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "YCOR:DOG:227:MPSLIMITS.E PP")
}

record(aSub, "YCOR:DOG:227:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "YCOR:DOG:227:MPS.RVAL")
  field(INPB, "YCOR:DOG:227:BADIFF")
  field(INPC, "YCOR:DOG:227:BDELTAS.N")
  field(INPD, "YCOR:DOG:227:BACT")
  field(INPE, "YCOR:DOG:227:MPSBITMASK.RVAL")
  field(INPF, "YCOR:DOG:227:MPSBLLIM")
  field(INPG, "YCOR:DOG:227:MPSBMIN")
  field(INPH, "YCOR:DOG:227:MPSBMAX")
  field(INPI, "YCOR:DOG:227:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "YCOR:DOG:227:INTOL.RVAL PP")
  field(OUTB, "YCOR:DOG:227:INTOL_BMIN.RVAL PP")
  field(OUTC, "YCOR:DOG:227:INTOL_BRANGE.RVAL PP")
  field(OUTD, "YCOR:DOG:227:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "YCOR:DOG:227:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:227:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:227:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:227:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:227:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:227:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:227:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:227:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "YCOR:DOG:227:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "YCOR:DOG:227:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:DOG:227:CHCKBTOL")
  field(INPB, "YCOR:DOG:227:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "YCOR:DOG:227:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "YCOR:DOG:227:CHCKBTOL")
  field(FLNK, "YCOR:DOG:227:CHCKITOL")
}

record(calc, "YCOR:DOG:227:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "YCOR:DOG:227:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "YCOR:DOG:227:BDES.HOPR")
  field(INPB, "YCOR:DOG:227:STABILITY")
  field(INPC, "YCOR:DOG:227:BDES.LOPR")
}

record(longout, "YCOR:DOG:227:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "YCOR:DOG:227:CHCKBTOL")
}

record(calc, "YCOR:DOG:227:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:DOG:227:POLYCOEF.B")
  field(INPB, "YCOR:DOG:227:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "YCOR:DOG:227:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "YCOR:DOG:227:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "YCOR:DOG:227:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "YCOR:DOG:227:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "YCOR:DOG:227:PAUGO")  
}

record(fanout, "YCOR:DOG:227:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "YCOR:DOG:227:PAUSTOP")
  field(LNK2, "YCOR:DOG:227:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "YCOR:DOG:227:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "YCOR:DOG:227:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:211:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:211:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "YCOR:DOG:227:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "YCOR:DOG:227:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:211:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:211:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "YCOR:DOG:227:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:211:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:DOG:227:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "YCOR:DOG:227:PSTYPE.RVAL")
  field(INPC, "YCOR:DOG:227:TURNEDOFF.RVAL")
  field(INPD, "YCOR:DOG:227:CONFIG.RVAL")
  field(INPE, "YCOR:DOG:227:PSCATEGORY.RVAL")
  field(INPF, "YCOR:DOG:227:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "YCOR:DOG:227:AUTOCTRL.RVAL")
  field(INPJ, "YCOR:DOG:227:OUTOFSERVICE.RVAL")
  field(INPL, "YCOR:DOG:227:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "YCOR:DOG:227:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "YCOR:DOG:227:PAU")
  field(INPP, "YCOR:DOG:227:CALBDISABLE.RVAL")
  field(INPQ, "YCOR:DOG:227:PTRBDISABLE.RVAL")
  field(INPR, "YCOR:DOG:227:TRIMDISABLE.RVAL")
  field(INPS, "YCOR:DOG:227:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "YCOR:DOG:227:FBCK")
  field(INPU, "YCOR:DOG:227:TRIMTYPE.RVAL")
  field(INPV, "YCOR:DOG:227:STDZDIRECT.RVAL")
  field(INPW, "YCOR:DOG:227:DEGAUSENABLE.RVAL")
  field(FLNK, "YCOR:DOG:227:HSTA")
}

record(longin, "YCOR:DOG:227:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "YCOR:DOG:227:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "YCOR:DOG:227:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "YCOR:DOG:227:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "YCOR:DOG:227:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:227:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:227:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:227:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by YCOR:DOG:227:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses YCOR:DOG:227:FBCK.
# This PV should be replaced by YCOR:DOG:227:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "YCOR:DOG:227:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "YCOR:DOG:227:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:DOG:227:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:227:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"YCOR:DOG:227:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "YCOR:DOG:227:OUTOFSERVICE NPP NMS")
  field(OUT,  "YCOR:DOG:227:ONLINE PP")
}
record(bo, "YCOR:DOG:227:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "YCOR:DOG:227:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:DOG:227:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "YCOR:DOG:227:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "YCOR:DOG:227:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "YCOR:DOG:227:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "YCOR:DOG:227:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "YCOR:DOG:227:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "YCOR:DOG:227:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:227:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:227:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:227:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "YCOR:DOG:227:TRIMTYPE")
}

record(stringout, "YCOR:DOG:227:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "YCOR:DOG:227:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "YCOR:DOG:227:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "YCOR:DOG:227:STATE.RVAL")
  field(INPB, "YCOR:DOG:227:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:DOG:227:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:DOG:227:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "YCOR:DOG:227:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "YCOR:DOG:227:STATE.RVAL")
  field(INPB, "YCOR:DOG:227:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:DOG:227:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:DOG:227:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "YCOR:DOG:227:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "YCOR:DOG:227:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "YCOR:DOG:227:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "YCOR:DOG:227:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "YCOR:DOG:227:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"YCOR:DOG:227:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("YCOR:DOG:227:TURNEDOFF",3140,1907,0,1,"YCOR:DOG:227:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:DOG:227:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "YCOR:DOG:227:BACT.STAT")
  field(INPB, "YCOR:DOG:227:BDES.STAT")
  field(INPC, "YCOR:DOG:227:IRIPL.STAT")
  field(INPD, "MCOR:EXT:211:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:211:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "YCOR:DOG:227:BACT.SEVR")
  field(INPH, "YCOR:DOG:227:BDES.SEVR")
  field(INPI, "YCOR:DOG:227:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:211:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:211:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "YCOR:DOG:227:STATE.RVAL")
  field(INPN, "YCOR:DOG:227:STDZOK")
  field(INPO, "YCOR:DOG:227:CALBOK")
  field(INPP, "YCOR:DOG:227:OUTOFSERVICE.RVAL")
  field(INPQ, "YCOR:DOG:227:CONFIG.RVAL")
  field(INPR, "YCOR:DOG:227:HSTA")
  field(INPS, "YCOR:DOG:227:CTRL.RVAL")
  field(INPT, "YCOR:DOG:227:DEGAUSOK") 
  field(INPV, "YCOR:DOG:227:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:227:STAT")
}

record(longout, "YCOR:DOG:227:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "YCOR:DOG:227:STATCTRLSUB")
  field(DOL, "YCOR:DOG:227:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "YCOR:DOG:227:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "YCOR:DOG:227:STAT")
  field(INPB, "YCOR:DOG:227:HSTA")
  field(INPD, "YCOR:DOG:227:ONOFFCTRL.RVAL")
  field(FLNK, "YCOR:DOG:227:STATMSG")
}

record(mbbo, "YCOR:DOG:227:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:DOG:227:UNAVAILGO")
  field(DOL, "YCOR:DOG:227:STATCTRLSUB.W")
}

record(seq, "YCOR:DOG:227:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "YCOR:DOG:227:STATSUB.U")
  field(LNK1, "YCOR:DOG:227:UNAVAIL PP")
}

record(stringout, "YCOR:DOG:227:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"YCOR:DOG:227:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - YCOR:DOG:227:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - YCOR:DOG:227:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"YCOR:DOG:227STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - YCOR:DOG:227:STATUS\nC - YCOR:DOG:227:ON\nD - YCOR:DOG:227:STDZOK\nE - YCOR:DOG:227:CALBOK\nF - YCOR:DOG:227:BACTDRIFT (future)\nG -\nH- YCOR:DOG:227:DACSTATUS\nI -YCOR:DOG:227:ADCSTATUS\nJ - YCOR:DOG:227:BACTSTATUS\nK - YCOR:DOG:227:BDESSTATUS\nL - YCOR:DOG:227:RIPLSTATUS\n\nOutput:\nP - YCOR:DOG:227:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "YCOR:DOG:227:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "YCOR:DOG:227:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "YCOR:DOG:227:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "YCOR:DOG:227:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "XCOR:DOG:252:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:212:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:DOG:252:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "XCOR:DOG:252:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:212:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "XCOR:DOG:252:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "2")
  field(LOLO, "-2")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "XCOR:DOG:252:BDELTAS")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "XCOR:DOG:252:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "XCOR:DOG:252:ICTRL PP")
}

# This record is processed by XCOR:DOG:252:ICON")
# Note: we are not setting alarms here.
record(ao, "XCOR:DOG:252:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(DOL,  "XCOR:DOG:252:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:252:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "XCOR:DOG:252:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(ao, "XCOR:DOG:252:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(FLNK, "XCOR:DOG:252:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "XCOR:DOG:252:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "XCOR:DOG:252:ISETPT.OMSL")

  field(DOL2, "XCOR:DOG:252:ICTRL")
  field(LNK2, "XCOR:DOG:252:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "XCOR:DOG:252:ISETPT.OMSL")
}

record(ao, "XCOR:DOG:252:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:252:IMIN")
}

record(ao, "XCOR:DOG:252:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(VAL,  "-2")
  field(FLNK, "XCOR:DOG:252:IRANGE")
}

record(sel, "XCOR:DOG:252:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(NVL,  "XCOR:DOG:252:BACT.SEVR")
  field(INPA, "XCOR:DOG:252:IACT NPP MS")
  field(INPB, "XCOR:DOG:252:IACTPREVOK NPP MS")
  field(INPC, "XCOR:DOG:252:IACTPREVOK NPP MS")
  field(INPD, "XCOR:DOG:252:IACTPREVOK NPP MS")
}

record(sub, "XCOR:DOG:252:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:252:IDES")
  field(INPB, "XCOR:DOG:252:ISETPT.DRVH")
  field(INPC, "XCOR:DOG:252:ISETPT.DRVL")
  field(INPD, "XCOR:DOG:252:IDELTAS.I")
  field(INPE, "XCOR:DOG:252:IDELTAS.J")
  field(INPG, "XCOR:DOG:252:STATE")
  field(INPH, "XCOR:DOG:252:HSTA")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:DOG:252:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:252:IDES")
  field(INPB, "XCOR:DOG:252:ISETPT.DRVH")
  field(INPC, "XCOR:DOG:252:ISETPT.DRVL")
  field(INPD, "XCOR:DOG:252:IDELTAS.K")
  field(INPE, "XCOR:DOG:252:IDELTAS.L")
  field(INPG, "XCOR:DOG:252:STATE")
  field(INPH, "XCOR:DOG:252:HSTA")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:DOG:252:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "XCOR:DOG:252:BLIMITS")
  field(LNK1, "XCOR:DOG:252:IACTLIMITS.F PP")
  field(DOL2, "XCOR:DOG:252:IACTLIMITS.I")
  field(LNK2, "XCOR:DOG:252:IACT.HIGH")
  field(DOL3, "XCOR:DOG:252:IACTLIMITS.J")
  field(LNK3, "XCOR:DOG:252:IACT.LOW")
  field(DOL4, "XCOR:DOG:252:IACTLIMITS.K")
  field(LNK4, "XCOR:DOG:252:IACT.HIHI")
  field(DOL5, "XCOR:DOG:252:IACTLIMITS.L")
  field(LNK5, "XCOR:DOG:252:IACT.LOLO")
  field(DOL6, "XCOR:DOG:252:BLIMITS")
  field(LNK6, "XCOR:DOG:252:IMONLIMITS.F PP")
  field(DOL7, "XCOR:DOG:252:IMONLIMITS.I")
  field(LNK7, "XCOR:DOG:252:IMON.HIGH")
  field(DOL8, "XCOR:DOG:252:IMONLIMITS.J")
  field(LNK8, "XCOR:DOG:252:IMON.LOW")
  field(DOL9, "XCOR:DOG:252:IMONLIMITS.K")
  field(LNK9, "XCOR:DOG:252:IMON.HIHI")
  field(DOLA, "XCOR:DOG:252:IMONLIMITS.L")
  field(LNKA, "XCOR:DOG:252:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "XCOR:DOG:252:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "XCOR:DOG:252:TRIMBTOL")
  field(INPE, "XCOR:DOG:252:CHCKBTOL")
  field(INPF, "XCOR:DOG:252:BDELTAS.K")
  field(INPG, "XCOR:DOG:252:BDELTAS.L")
  field(INPH, "XCOR:DOG:252:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "XCOR:DOG:252:STDZITOLR")
  field(INPC, "XCOR:DOG:252:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:212:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "XCOR:DOG:252:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:212:RESET PP
#
record(bo, "XCOR:DOG:252:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:212:RESET PP")
}

record(bo, "XCOR:DOG:252:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:212:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "XCOR:DOG:252:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "XCOR:DOG:252:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:212:IRAMPRATE PP")
  field(FLNK, "XCOR:DOG:252:STDZDLY")
}


record(ao, "XCOR:DOG:252:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:212:ISETPT PP")
  field(DOL, "XCOR:DOG:252:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "XCOR:DOG:252:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:212:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:DOG:252:BMON")
}

record(ao, "XCOR:DOG:252:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:212:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "XCOR:DOG:252:IRIPLOK")
}

record(sub, "XCOR:DOG:252:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "XCOR:DOG:252:IRIPL.VAL")
  field(INPB, "XCOR:DOG:252:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:DOG:252:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:DOG:252:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "XCOR:DOG:252:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:212:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "XCOR:DOG:252:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:212:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "XCOR:DOG:252:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:DOG:252:IACTPREVOK")
  field(LNK2, "XCOR:DOG:252:IDIFF")
  field(LNK3, "XCOR:DOG:252:IADIFF")
  field(LNK4, "XCOR:DOG:252:IRATIO")
  field(LNK5, "XCOR:DOG:252:IDIRECT")
  field(LNK6, "XCOR:DOG:252:IACTPOL_CHECK")
}

record(calc, "XCOR:DOG:252:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:DOG:252:IDES")
  field(INPB, "XCOR:DOG:252:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "2")
  field(LOPR, "-2")
}

record(calc, "XCOR:DOG:252:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "XCOR:DOG:252:IDIFF")
  field(PREC, "9")
}

record(calc, "XCOR:DOG:252:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:DOG:252:IDIFF")
  field(INPB, "XCOR:DOG:252:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "XCOR:DOG:252:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "XCOR:DOG:252:IMIN")
  field(INPB,   "XCOR:DOG:252:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "XCOR:DOG:252:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "XCOR:DOG:252:IACT")
  field(INPB, "XCOR:DOG:252:IDES")
  field(INPC, "XCOR:DOG:252:ISETPT")
  field(INPD, "XCOR:DOG:252:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "XCOR:DOG:252:IADJUST PP")
}

record(bo, "XCOR:DOG:252:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "XCOR:DOG:252:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "XCOR:DOG:252:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "XCOR:DOG:252:IACT")
  field(FLNK, "XCOR:DOG:252:IACTPOL")
}
record(bo, "XCOR:DOG:252:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:DOG:252:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"XCOR:DOG:252:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:DOG:252:IDELTAS and the\n  XCOR:DOG:252:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"XCOR:DOG:252:IACT: \n  Get copy of XCOR:DOG:252:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"XCOR:DOG:252:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"XCOR:DOG:252:IDES:\n  Contains raw value calculated by \nXCOR:DOG:252:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nXCOR:DOG:252:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"XCOR:DOG:252:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  XCOR:DOG:252:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               XCOR:DOG:252:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"XCOR:DOG:252:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by XCOR:DOG:252:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, XCOR:DOG:252:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  XCOR:DOG:252:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "XCOR:DOG:252:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:252:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:DOG:252:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:DOG:252:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:DOG:252:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "XCOR:DOG:252:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "XCOR:DOG:252:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "XCOR:DOG:252:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "XCOR:DOG:252:TRIMTYPE.RVAL")
  field(INPB,   "XCOR:DOG:252:CONFIG.RVAL")
  field(OUT,    "XCOR:DOG:252:TRIMMAXNUM PP")
}
record(longout, "XCOR:DOG:252:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "XCOR:DOG:252:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "XCOR:DOG:252:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "XCOR:DOG:252:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "XCOR:DOG:252:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "XCOR:DOG:252:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "XCOR:DOG:252:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "XCOR:DOG:252:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "XCOR:DOG:252:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "XCOR:DOG:252:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "XCOR:DOG:252:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "XCOR:DOG:252:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "XCOR:DOG:252:IMOVE")
 field(INPB, "XCOR:DOG:252:IACT")
 field(INPC, "XCOR:DOG:252:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "XCOR:DOG:252:TRIMDLYPCT")
 field(INPF, "XCOR:DOG:252:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "XCOR:DOG:252:RAMPTIME_LEFT PP")
}

record(longout, "XCOR:DOG:252:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "XCOR:DOG:252:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "XCOR:DOG:252:RAMPDONE_CALC")
}

record(calc, "XCOR:DOG:252:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "XCOR:DOG:252:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "XCOR:DOG:252:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "XCOR:DOG:252:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:DOG:252:RAMPTIME_LEFT")
 field(OUT,  "XCOR:DOG:252:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "XCOR:DOG:252:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:DOG:252:RAMPTIME_LEFT NMS")
 field(OUT,  "XCOR:DOG:252:RAMPDONE PP")
}

record(bo, "XCOR:DOG:252:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "XCOR:DOG:252:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "XCOR:DOG:252:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "XCOR:DOG:252:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:252:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "XCOR:DOG:252:DEBUG.PROC PP")
  field(LNK2, "XCOR:DOG:252:STDZCYCLENUM.PROC PP")
  field(LNK3, "XCOR:DOG:252:STDZDISABLE.PROC PP")
  field(LNK4, "XCOR:DOG:252:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "XCOR:DOG:252:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "XCOR:DOG:252:STDZIMIN NPP NMS")
  field(INPB, "XCOR:DOG:252:STDZIMAX NPP NMS")
  field(INPC, "XCOR:DOG:252:STDZIFINAL NPP NMS")
  field(INPD, "XCOR:DOG:252:STDZCYCLENUM NPP NMS")
  field(INPE, "XCOR:DOG:252:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "XCOR:DOG:252:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "XCOR:DOG:252:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "XCOR:DOG:252:STDZWF PP")
  field(OUTB, "XCOR:DOG:252:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "XCOR:DOG:252:STDZWF")
}

record(mbbo, "XCOR:DOG:252:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "XCOR:DOG:252:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "XCOR:DOG:252:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "XCOR:DOG:252:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "XCOR:DOG:252:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "XCOR:DOG:252:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "XCOR:DOG:252:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:DOG:252:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:DOG:252:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "XCOR:DOG:252:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:252:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "XCOR:DOG:252:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "XCOR:DOG:252:STDZIMIN")
}

record(ao, "XCOR:DOG:252:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "XCOR:DOG:252:STDZIMAX")
}

record(ao, "XCOR:DOG:252:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:252:STDZIFINAL")
}

record(ao, "XCOR:DOG:252:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL,  "-2")
  field(FLNK, "XCOR:DOG:252:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "XCOR:DOG:252:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "XCOR:DOG:252:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "XCOR:DOG:252:STDZIMIN CP NMS")
  field(INPB, "XCOR:DOG:252:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "XCOR:DOG:252:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "XCOR:DOG:252:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "XCOR:DOG:252:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "XCOR:DOG:252:STDZIMIN CP NMS")
  field(INPB, "XCOR:DOG:252:STDZIMAX CP NMS")
  field(INPC, "XCOR:DOG:252:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:252:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "XCOR:DOG:252:TRIMDLYPCT CP MS")
  field(INPB, "XCOR:DOG:252:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "XCOR:DOG:252:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "XCOR:DOG:252:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:252:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "XCOR:DOG:252:IDES.HOPR")
  field(INPB, "XCOR:DOG:252:STDZMINIPCT CPP NMS")
  field(INPC, "XCOR:DOG:252:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "XCOR:DOG:252:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "XCOR:DOG:252:IDES.HOPR")
  field(INPB, "XCOR:DOG:252:IDES.LOPR")
  field(INPC, "XCOR:DOG:252:STDZDIRECT.RVAL")
  field(INPD, "XCOR:DOG:252:STDZMINIDELTA")
  field(INPE, "XCOR:DOG:252:IDES")
  field(PREC, "5")
  field(FLNK, "XCOR:DOG:252:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "XCOR:DOG:252:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "XCOR:DOG:252:IDES.HOPR")
  field(INPB, "XCOR:DOG:252:IDES.LOPR")
  field(INPC, "XCOR:DOG:252:STDZDIRECT.RVAL")
  field(INPD, "XCOR:DOG:252:STDZMINIDELTA")
  field(INPE, "XCOR:DOG:252:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "XCOR:DOG:252:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "XCOR:DOG:252:IADJUST.RVAL")
  field(INPB, "XCOR:DOG:252:STDZDIRECT.RVAL")
  field(INPC, "XCOR:DOG:252:STDZOK.RVAL")
  field(INPD, "XCOR:DOG:252:STDZDISABLE.RVAL")
  field(INPE, "XCOR:DOG:252:STATE.RVAL CPP NMS")
  field(INPF, "XCOR:DOG:252:ICTRL.RVAL")
  field(INPG, "XCOR:DOG:252:STATE.SEVR")
  field(INPH, "XCOR:DOG:252:BDELTAS.M")
  field(INPI, "XCOR:DOG:252:IACT.SEVR")
  field(OUT,  "XCOR:DOG:252:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "XCOR:DOG:252:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "XCOR:DOG:252:STDZLOSTTOD.PROC")
  field(LNK2, "XCOR:DOG:252:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "XCOR:DOG:252:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:252:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:DOG:252:IACT CP")
  field(INPB, "XCOR:DOG:252:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "XCOR:DOG:252:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "XCOR:DOG:252:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:252:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:DOG:252:STDZIACTMAX")
  field(INPB, "XCOR:DOG:252:IACT")
  field(INPC, "XCOR:DOG:252:IDELTAS.I")
  field(OUT,  "XCOR:DOG:252:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "XCOR:DOG:252:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "XCOR:DOG:252:STDZOK.RVAL CP")
  field(INPB, "XCOR:DOG:252:STDZDISABLE.RVAL CP")
  field(INPC, "XCOR:DOG:252:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "XCOR:DOG:252:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "XCOR:DOG:252:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "XCOR:DOG:252:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "XCOR:DOG:252:CALBOK")
  field(INPB, "XCOR:DOG:252:CALBDISABLE")
  field(INPC, "XCOR:DOG:252:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "XCOR:DOG:252:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "XCOR:DOG:252:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "XCOR:DOG:252:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "XCOR:DOG:252:CALBSLOPE")
  field(DOL3, "XCOR:DOG:252:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "XCOR:DOG:252:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:252:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "XCOR:DOG:252:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "XCOR:DOG:252:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "XCOR:DOG:252:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "XCOR:DOG:252:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "XCOR:DOG:252:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:252:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "XCOR:DOG:252:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:252:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "XCOR:DOG:252:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "XCOR:DOG:252:IACT")
  field(INPD, "XCOR:DOG:252:DACSLOPE")
  field(INPE, "XCOR:DOG:252:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "XCOR:DOG:252:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "XCOR:DOG:252:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "2")
  field(HOPR, "2")
  field(DRVL, "-2")
  field(LOPR, "-2")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "XCOR:DOG:252:CALBIMAX")
}

record(ao, "XCOR:DOG:252:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "2")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVL, "-2")
  field(EGU,  "A")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:252:CALBSTEPNUM")
}

record(ao, "XCOR:DOG:252:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(VAL, "0")
}

record(longout, "XCOR:DOG:252:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:DOG:252:CALBIDELTA")
}

record(calc, "XCOR:DOG:252:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "XCOR:DOG:252:CALBIMAX")
  field(INPB, "XCOR:DOG:252:CALBIMIN")
  field(INPC, "XCOR:DOG:252:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "XCOR:DOG:252:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:212:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:212:IACT.HOPR")
  field(INPC, "XCOR:DOG:252:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "XCOR:DOG:252:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:DOG:252:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:252:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:252:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:252:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "XCOR:DOG:252:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:252:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:252:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:252:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "XCOR:DOG:252:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:252:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:252:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:252:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:DOG:252:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:252:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:252:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "XCOR:DOG:252:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:252:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "XCOR:DOG:252:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "XCOR:DOG:252:CALBSTEPNUM")
  field(INPB, "XCOR:DOG:252:CALBIACTWF")
  field(INPC, "XCOR:DOG:252:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "XCOR:DOG:252:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "XCOR:DOG:252:STDZITOL")

  field(INPH, "XCOR:DOG:252:DACSLOPE")
  field(INPI, "XCOR:DOG:252:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "XCOR:DOG:252:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "XCOR:DOG:252:CALBSTEPNUM")
  field(INPB, "XCOR:DOG:252:CALBIACTWF")
  field(INPC, "XCOR:DOG:252:DACWF")
  field(INPF, "XCOR:DOG:252:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe XCOR:DOG:252CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "XCOR:DOG:252:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "XCOR:DOG:252:DEGAUSIMIN.PROC PP")
  field(OUTB, "XCOR:DOG:252:DEGAUSIMAX.PROC PP")
  field(OUTC, "XCOR:DOG:252:DEGAUSTYPE.PROC PP")
  field(OUTD, "XCOR:DOG:252:DEGAUSSTEP.PROC PP")
  field(OUTE, "XCOR:DOG:252:MADNAME.PROC PP")
  field(OUTF, "XCOR:DOG:252:PSTYPE.PROC PP")
  field(OUTG, "XCOR:DOG:252:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "XCOR:DOG:252:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:DOG:252:DEGAUSIMIN NPP NMS")
  field(INPB, "XCOR:DOG:252:DEGAUSIMAX NPP NMS")
  field(INPC, "XCOR:DOG:252:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "XCOR:DOG:252:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "XCOR:DOG:252:PSTYPE NPP NMS")
  field(INPG, "XCOR:DOG:252:DEBUG.RVAL NPP NMS")
  field(INPH, "XCOR:DOG:252:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "XCOR:DOG:252:DEGAUSWF PP")
  field(OUTB, "XCOR:DOG:252:DEGAUSMSG PP")
  field(OUTC, "XCOR:DOG:252:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "XCOR:DOG:252:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"XCOR:DOG:252:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "XCOR:DOG:252:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "XCOR:DOG:252:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "XCOR:DOG:252:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "XCOR:DOG:252:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "XCOR:DOG:252:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "-2")
}
record(ao, "XCOR:DOG:252:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"XCOR:DOG:252:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "XCOR:DOG:252:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"XCOR:DOG:252:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "XCOR:DOG:252:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "XCOR:DOG:252:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "XCOR:DOG:252:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "XCOR:DOG:252:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:DOG:252:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:252:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:DOG:252:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:DOG:252:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "XCOR:DOG:252:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "XCOR:DOG:252:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "XCOR:DOG:252:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "XCOR:DOG:252:DEGAUS_IMAX")
  field(INPB, "XCOR:DOG:252:ISETPT")
  field(INPC, "XCOR:DOG:252:DEGAUSTYPE.RVAL")
  field(OUT,  "XCOR:DOG:252:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "XCOR:DOG:252:DEGAUS_IMAX_UPDATE")
}
record(seq, "XCOR:DOG:252:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "XCOR:DOG:252:ISETPT")
  field(LNK1, "XCOR:DOG:252:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "XCOR:DOG:252:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "2")
  field(LOPR, "-2")
  field(DRVH, "2")
  field(DRVL, "-2")
  field(VAL,  "2")
  field(FLNK, "XCOR:DOG:252:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "XCOR:DOG:252:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "XCOR:DOG:252:DEGAUS_IMAX")
  field(FLNK, "XCOR:DOG:252:DEGAUS_IMAXPOL")
}
record(bo, "XCOR:DOG:252:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:DOG:252:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "XCOR:DOG:252:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "XCOR:DOG:252:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "XCOR:DOG:252:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "2")
  field(LOPR, "-2")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "XCOR:DOG:252:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "XCOR:DOG:252:IACT")
  field(INPB, "XCOR:DOG:252:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "XCOR:DOG:252:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "XCOR:DOG:252:IACTPOL")
}
record(bo, "XCOR:DOG:252:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"XCOR:DOG:252:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "XCOR:DOG:252:DEGAUSENABLE CP")
  field(INPB, "XCOR:DOG:252:DEGAUSOK")
  field(INPC, "XCOR:DOG:252:STATE CP")
  field(INPD, "XCOR:DOG:252:STATE.SEVR")
  field(OUT,  "XCOR:DOG:252:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "XCOR:DOG:252:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "XCOR:DOG:252:DEGAUS_STATE_CHECK")
  field(LNK1, "XCOR:DOG:252:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "XCOR:DOG:252:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "XCOR:DOG:252:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "XCOR:DOG:252:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "XCOR:DOG:252:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "XCOR:DOG:252:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:DOG:252:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "XCOR:DOG:252:STATMSG.FRSV")
  field(LNK4, "XCOR:DOG:252:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:DOG:252:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:252:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:DOG:252:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "XCOR:DOG:252:STATMSG.FRSV")
  field(LNK4, "XCOR:DOG:252:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:DOG:252:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "XCOR:DOG:252:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "XCOR:DOG:252:STATMSG.FRSV")
  field(LNK3, "XCOR:DOG:252:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "XCOR:DOG:252:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:252:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "XCOR:DOG:252:STATMSG.FRSV PP")
  field(LNK3, "XCOR:DOG:252:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "XCOR:DOG:252:FUNC") {
  field(DESC, "XCOR:DOG:252 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "XCOR:DOG:252:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:DOG:252:CTRL") {
  field(DESC, "XCOR:DOG:252 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "XCOR:DOG:252:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "XCOR:DOG:252:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "XCOR:DOG:252:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "XCOR:DOG:252:BUSY") {
  field(DESC, "XCOR:DOG:252 Ctrl Done")
  field(DOL, "XCOR:DOG:252:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:252:SELECT")
}

record(bo, "XCOR:DOG:252:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "XCOR:DOG:252:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:DOG:252:CTRLSTATE") {
  field(DESC, "XCOR:DOG:252 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("XCOR:DOG:252:CTRL",20,20,0,0,"XCOR:DOG:252:CTRL")
#! Field("XCOR:DOG:252:CTRL.OUT",16777215,1,"XCOR:DOG:252:CTRL.OUT")
#! Link("XCOR:DOG:252:CTRL.OUT","XCOR:DOG:252:SELECTEN.A")
#! Field("XCOR:DOG:252:CTRL.VAL",16777215,1,"XCOR:DOG:252:CTRL.VAL")
#! Record("XCOR:DOG:252:SELECTEN",321,381,0,0,"XCOR:DOG:252:SELECTEN")
#! Field("XCOR:DOG:252:SELECTEN.A",16777215,0,"XCOR:DOG:252:SELECTEN.A")
#! Field("XCOR:DOG:252:SELECTEN.FLNK",16777215,1,"XCOR:DOG:252:SELECTEN.FLNK")
#! Link("XCOR:DOG:252:SELECTEN.FLNK","XCOR:DOG:252:BUSY")
#! Field("XCOR:DOG:252:SELECTEN.VAL",16777215,1,"XCOR:DOG:252:SELECTEN.VAL")
#! Record("XCOR:DOG:252:BUSY",623,274,0,0,"XCOR:DOG:252:BUSY")
#! Field("XCOR:DOG:252:BUSY.DOL",16777215,0,"XCOR:DOG:252:BUSY.DOL")
#! Link("XCOR:DOG:252:BUSY.DOL","XCOR:DOG:252:SELECTEN.VAL")
#! Field("XCOR:DOG:252:BUSY.FLNK",16777215,1,"XCOR:DOG:252:BUSY.FLNK")
#! Link("XCOR:DOG:252:BUSY.FLNK","XCOR:DOG:252:SELECT")
#! Record("XCOR:DOG:252:SELECT",669,508,0,1,"XCOR:DOG:252:SELECT")
#! Record("XCOR:DOG:252:FUNC",940,120,0,0,"XCOR:DOG:252:FUNC")
#! Field("XCOR:DOG:252:FUNC.OUT",16777215,0,"XCOR:DOG:252:FUNC.OUT")
#! Link("XCOR:DOG:252:FUNC.OUT","XCOR:DOG:252:CTRL.VAL")
#! Record("XCOR:DOG:252:ABORT",193,41,0,0,"XCOR:DOG:252:ABORT")
#! Record("XCOR:DOG:252:CTRLSTATE",369,34,0,0,"XCOR:DOG:252:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"XCOR:DOG:252:SELECT is used for Multi-device selection.\nIt is enabled when associated XCOR:DOG:252:CTRL is \"0\" (DONE).\nIt is disabled when associated XCOR:DOG:252:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"XCOR:DOG:252:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "XCOR:DOG:252:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "XCOR:DOG:252:BCTRL.SEVR")
  field(OUT,  "XCOR:DOG:252:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "XCOR:DOG:252:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:DOG:252:BACT")
  field(INPB, "XCOR:DOG:252:POLYCOEF")
  field(INPC, "XCOR:DOG:252:POLYCOEF.A")
  field(INPD, "XCOR:DOG:252:POLYCOEF.B")
  field(INPE, "XCOR:DOG:252:IACT MS")
  field(INPF, "XCOR:DOG:252:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
  field(FLNK, "XCOR:DOG:252:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "XCOR:DOG:252:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:DOG:252:BDES")
  field(INPB, "XCOR:DOG:252:TRIMBTOL")
  field(INPC, "XCOR:DOG:252:TRIMBTOLR")
  field(INPD, "XCOR:DOG:252:CHCKBTOL")
  field(INPE, "XCOR:DOG:252:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "XCOR:DOG:252:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "XCOR:DOG:252:MPSBTOL")
  field(INPQ, "XCOR:DOG:252:MPSBTOLR")
  field(FLNK, "XCOR:DOG:252:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "XCOR:DOG:252:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "XCOR:DOG:252:BDES")
  field(INPB, "XCOR:DOG:252:BDELTAS.I")
  field(INPG, "XCOR:DOG:252:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "XCOR:DOG:252:BCON.HIGH")
  field(OUTB, "XCOR:DOG:252:BCON.LOW")
  field(OUTC, "XCOR:DOG:252:BCON.HIHI")
  field(OUTD, "XCOR:DOG:252:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:252:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "XCOR:DOG:252:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:DOG:252:BDIFF")
  field(LNK2, "XCOR:DOG:252:BADIFF")
  field(LNK3, "XCOR:DOG:252:BRATIO")
  field(LNK4, "XCOR:DOG:252:MPSLIMITS")
  field(LNK5, "XCOR:DOG:252:I2BSTATUS")
  field(LNK6, "XCOR:DOG:252:IACTFO.PROC")
}

record(calc, "XCOR:DOG:252:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:DOG:252:BDES")
  field(INPB, "XCOR:DOG:252:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "XCOR:DOG:252:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "XCOR:DOG:252:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "XCOR:DOG:252:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:DOG:252:BDIFF")
  field(INPB, "XCOR:DOG:252:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "XCOR:DOG:252:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "XCOR:DOG:252:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "XCOR:DOG:252:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:DOG:252:BMON")
  field(INPB, "XCOR:DOG:252:POLYCOEF")
  field(INPC, "XCOR:DOG:252:POLYCOEF.A")
  field(INPD, "XCOR:DOG:252:POLYCOEF.B")
  field(INPE, "XCOR:DOG:252:IMON MS")
  field(INPF, "XCOR:DOG:252:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(HIHI, "0.02098636")
  field(LOLO, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.02098636")
  field(LOW,  "-0.02098636")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:212:BDES CP
record(ao,  "XCOR:DOG:252:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.02098636")
   field(DRVL, "-0.02098636")
   field(HOPR, "0.02098636")
   field(LOPR, "-0.02098636")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "XCOR:DOG:252:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "XCOR:DOG:252:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:252:POLYCOEF")
  field(INPC, "XCOR:DOG:252:POLYCOEF.A")
  field(INPD, "XCOR:DOG:252:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "XCOR:DOG:252:BDES.DRVH")
  field(INPF, "XCOR:DOG:252:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:252:IDES")
}
record(sub, "XCOR:DOG:252:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:252:POLYCOEF")
  field(INPC, "XCOR:DOG:252:POLYCOEF.A")
  field(INPD, "XCOR:DOG:252:POLYCOEF.B")
  field(INPE, "XCOR:DOG:252:BDES.DRVH")
  field(INPF, "XCOR:DOG:252:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "XCOR:DOG:252:INOM")
}

record(sub, "XCOR:DOG:252:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:252:BDES.VAL")
  field(INPB, "XCOR:DOG:252:BDES.DRVH")
  field(INPC, "XCOR:DOG:252:BDES.DRVL")
  field(INPD, "XCOR:DOG:252:BDELTAS.I")
  field(INPE, "XCOR:DOG:252:BDELTAS.J")
  field(INPG, "XCOR:DOG:252:STATE")
  field(INPH, "XCOR:DOG:252:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:DOG:252:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:252:BDES.VAL")
  field(INPB, "XCOR:DOG:252:BDES.DRVH")
  field(INPC, "XCOR:DOG:252:BDES.DRVL")
  field(INPD, "XCOR:DOG:252:BDELTAS.K")
  field(INPE, "XCOR:DOG:252:BDELTAS.L")
  field(INPG, "XCOR:DOG:252:STATE")
  field(INPH, "XCOR:DOG:252:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:DOG:252:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "XCOR:DOG:252:BLIMITS")
  field(LNK1, "XCOR:DOG:252:BACTLIMITS.F PP")
  field(DOL2, "XCOR:DOG:252:BACTLIMITS.I")
  field(LNK2, "XCOR:DOG:252:BACT.HIGH")
  field(DOL3, "XCOR:DOG:252:BACTLIMITS.J")
  field(LNK3, "XCOR:DOG:252:BACT.LOW")
  field(DOL4, "XCOR:DOG:252:BACTLIMITS.K")
  field(LNK4, "XCOR:DOG:252:BACT.HIHI")
  field(DOL5, "XCOR:DOG:252:BACTLIMITS.L")
  field(LNK5, "XCOR:DOG:252:BACT.LOLO")
  field(DOL6, "XCOR:DOG:252:BLIMITS")
  field(LNK6, "XCOR:DOG:252:BMONLIMITS.F PP")
  field(DOL7, "XCOR:DOG:252:BMONLIMITS.I")
  field(LNK7, "XCOR:DOG:252:BMON.HIGH")
  field(DOL8, "XCOR:DOG:252:BMONLIMITS.J")
  field(LNK8, "XCOR:DOG:252:BMON.LOW")
  field(DOL9, "XCOR:DOG:252:BMONLIMITS.K")
  field(LNK9, "XCOR:DOG:252:BMON.HIHI")
  field(DOLA, "XCOR:DOG:252:BMONLIMITS.L")
  field(LNKA, "XCOR:DOG:252:BMON.LOLO")
  field(FLNK, "XCOR:DOG:252:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "XCOR:DOG:252:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "XCOR:DOG:252:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "XCOR:DOG:252:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:252:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "XCOR:DOG:252:BCTRL.VAL")
  field(LNK2, "XCOR:DOG:252:BDES PP")

  field(DOL3, "1")
  field(LNK3, "XCOR:DOG:252:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "XCOR:DOG:252:CHECKSTDZLOST.PROC PP")

  field(DOL5, "XCOR:DOG:252:BCTRL.VAL")
  field(LNK5, "XCOR:DOG:252:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "XCOR:DOG:252:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "XCOR:DOG:252:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:252:POLYCOEF")
  field(INPC, "XCOR:DOG:252:POLYCOEF.A")
  field(INPD, "XCOR:DOG:252:POLYCOEF.B")
  field(INPE, "XCOR:DOG:252:BDES.DRVH")
  field(INPF, "XCOR:DOG:252:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:252:ISETPT")
}

record(ao, "XCOR:DOG:252:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "XCOR:DOG:252:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "XCL1P")
}

record(ai, "XCOR:DOG:252:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "753.890175")
}

record(ao, "XCOR:DOG:252:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(FLNK, "XCOR:DOG:252:BSTEP")
}

record(ao, "XCOR:DOG:252:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU, "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(FLNK, "XCOR:DOG:252:BSTEP")
}

record(ao, "XCOR:DOG:252:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by XCOR:DOG:252:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "XCOR:DOG:252:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "XCOR:DOG:252:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "XCOR:DOG:252:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:252:POLYCOEF")
  field(INPC, "XCOR:DOG:252:POLYCOEF.A")
  field(INPD, "XCOR:DOG:252:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.02098636")
  field(LOPR, "-0.02098636")
  field(MDEL, "-1")
  field(INPE, "XCOR:DOG:252:BCON.DRVH")
  field(INPF, "XCOR:DOG:252:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:252:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "XCOR:DOG:252:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "XCOR:DOG:252:BMAX")
  field(INPB, "XCOR:DOG:252:BMIN")
  field(INPC, "XCOR:DOG:252:BMIN.SEVR")
  field(INPD, "XCOR:DOG:252:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"XCOR:DOG:252:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "XCOR:DOG:252:ONLINE CP")
  field(OUT,  "XCOR:DOG:252:BCTRLDISABLEFOUT PP")
}

record(fanout, "XCOR:DOG:252:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "XCOR:DOG:252:BCTRLDISABLECALC")
  field(LNK1, "XCOR:DOG:252:BCTRLDISABLE")
  field(LNK2, "XCOR:DOG:252:BCTRLENABLE")
}

record(stringout, "XCOR:DOG:252:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:DOG:252:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "XCOR:DOG:252:BCTRLDISV_UPDATE")
}

record(stringout, "XCOR:DOG:252:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:DOG:252:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "XCOR:DOG:252:BCTRLDISV_UPDATE")
}

record(calcout, "XCOR:DOG:252:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "XCOR:DOG:252:ONLINE")
  field(OUT,  "XCOR:DOG:252:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"XCOR:DOG:252:BACT and MON\n  are processed via links from \n  XCOR:DOG:252:IACT (device raw value readback 1)\n  and\n  XCOR:DOG:252:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from XCOR:DOG:252:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = XCOR:DOG:252:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"XCOR:DOG:252:BDES\n  is processed when set by CA users or \n  XCOR:DOG:252:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"XCOR:DOG:252:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  XCOR:DOG:252:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (XCOR:DOG:252:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"XCOR:DOG:252:B*LIMITS and XCOR:DOG:252:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:DOG:252:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"XCOR:DOG:252:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"XCOR:DOG:252:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "XCOR:DOG:252:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:252:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "XCOR:DOG:252:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "XCOR:DOG:252:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:252:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:252:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:252:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.02098636")
  field(DRVL, "-0.02098636")
  field(PINI, "YES")
  field(VAL, "-0.02098636")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "XCOR:DOG:252:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "XCOR:DOG:252:MPSLIMITS.E PP")
}

record(aSub, "XCOR:DOG:252:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "XCOR:DOG:252:MPS.RVAL")
  field(INPB, "XCOR:DOG:252:BADIFF")
  field(INPC, "XCOR:DOG:252:BDELTAS.N")
  field(INPD, "XCOR:DOG:252:BACT")
  field(INPE, "XCOR:DOG:252:MPSBITMASK.RVAL")
  field(INPF, "XCOR:DOG:252:MPSBLLIM")
  field(INPG, "XCOR:DOG:252:MPSBMIN")
  field(INPH, "XCOR:DOG:252:MPSBMAX")
  field(INPI, "XCOR:DOG:252:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "XCOR:DOG:252:INTOL.RVAL PP")
  field(OUTB, "XCOR:DOG:252:INTOL_BMIN.RVAL PP")
  field(OUTC, "XCOR:DOG:252:INTOL_BRANGE.RVAL PP")
  field(OUTD, "XCOR:DOG:252:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "XCOR:DOG:252:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:252:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:252:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:252:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:252:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:252:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:252:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:252:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "XCOR:DOG:252:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "XCOR:DOG:252:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:DOG:252:CHCKBTOL")
  field(INPB, "XCOR:DOG:252:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "XCOR:DOG:252:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "XCOR:DOG:252:CHCKBTOL")
  field(FLNK, "XCOR:DOG:252:CHCKITOL")
}

record(calc, "XCOR:DOG:252:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "XCOR:DOG:252:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "XCOR:DOG:252:BDES.HOPR")
  field(INPB, "XCOR:DOG:252:STABILITY")
  field(INPC, "XCOR:DOG:252:BDES.LOPR")
}

record(longout, "XCOR:DOG:252:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "XCOR:DOG:252:CHCKBTOL")
}

record(calc, "XCOR:DOG:252:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:DOG:252:POLYCOEF.B")
  field(INPB, "XCOR:DOG:252:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "XCOR:DOG:252:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "XCOR:DOG:252:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "XCOR:DOG:252:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "XCOR:DOG:252:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "XCOR:DOG:252:PAUGO")  
}

record(fanout, "XCOR:DOG:252:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "XCOR:DOG:252:PAUSTOP")
  field(LNK2, "XCOR:DOG:252:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "XCOR:DOG:252:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "XCOR:DOG:252:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:212:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:212:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "XCOR:DOG:252:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "XCOR:DOG:252:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:212:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:212:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "XCOR:DOG:252:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:212:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:DOG:252:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "XCOR:DOG:252:PSTYPE.RVAL")
  field(INPC, "XCOR:DOG:252:TURNEDOFF.RVAL")
  field(INPD, "XCOR:DOG:252:CONFIG.RVAL")
  field(INPE, "XCOR:DOG:252:PSCATEGORY.RVAL")
  field(INPF, "XCOR:DOG:252:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "XCOR:DOG:252:AUTOCTRL.RVAL")
  field(INPJ, "XCOR:DOG:252:OUTOFSERVICE.RVAL")
  field(INPL, "XCOR:DOG:252:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "XCOR:DOG:252:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "XCOR:DOG:252:PAU")
  field(INPP, "XCOR:DOG:252:CALBDISABLE.RVAL")
  field(INPQ, "XCOR:DOG:252:PTRBDISABLE.RVAL")
  field(INPR, "XCOR:DOG:252:TRIMDISABLE.RVAL")
  field(INPS, "XCOR:DOG:252:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "XCOR:DOG:252:FBCK")
  field(INPU, "XCOR:DOG:252:TRIMTYPE.RVAL")
  field(INPV, "XCOR:DOG:252:STDZDIRECT.RVAL")
  field(INPW, "XCOR:DOG:252:DEGAUSENABLE.RVAL")
  field(FLNK, "XCOR:DOG:252:HSTA")
}

record(longin, "XCOR:DOG:252:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "XCOR:DOG:252:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "XCOR:DOG:252:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "XCOR:DOG:252:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "XCOR:DOG:252:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:252:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:252:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:252:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by XCOR:DOG:252:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses XCOR:DOG:252:FBCK.
# This PV should be replaced by XCOR:DOG:252:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "XCOR:DOG:252:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "XCOR:DOG:252:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:DOG:252:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:252:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"XCOR:DOG:252:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "XCOR:DOG:252:OUTOFSERVICE NPP NMS")
  field(OUT,  "XCOR:DOG:252:ONLINE PP")
}
record(bo, "XCOR:DOG:252:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "XCOR:DOG:252:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:DOG:252:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "XCOR:DOG:252:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "XCOR:DOG:252:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "XCOR:DOG:252:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "XCOR:DOG:252:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "XCOR:DOG:252:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "XCOR:DOG:252:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:252:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:252:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:252:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "XCOR:DOG:252:TRIMTYPE")
}

record(stringout, "XCOR:DOG:252:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "XCOR:DOG:252:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "XCOR:DOG:252:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "XCOR:DOG:252:STATE.RVAL")
  field(INPB, "XCOR:DOG:252:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:DOG:252:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:DOG:252:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "XCOR:DOG:252:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "XCOR:DOG:252:STATE.RVAL")
  field(INPB, "XCOR:DOG:252:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:DOG:252:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:DOG:252:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "XCOR:DOG:252:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "XCOR:DOG:252:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "XCOR:DOG:252:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "XCOR:DOG:252:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "XCOR:DOG:252:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"XCOR:DOG:252:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("XCOR:DOG:252:TURNEDOFF",3140,1907,0,1,"XCOR:DOG:252:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:DOG:252:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "XCOR:DOG:252:BACT.STAT")
  field(INPB, "XCOR:DOG:252:BDES.STAT")
  field(INPC, "XCOR:DOG:252:IRIPL.STAT")
  field(INPD, "MCOR:EXT:212:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:212:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "XCOR:DOG:252:BACT.SEVR")
  field(INPH, "XCOR:DOG:252:BDES.SEVR")
  field(INPI, "XCOR:DOG:252:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:212:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:212:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "XCOR:DOG:252:STATE.RVAL")
  field(INPN, "XCOR:DOG:252:STDZOK")
  field(INPO, "XCOR:DOG:252:CALBOK")
  field(INPP, "XCOR:DOG:252:OUTOFSERVICE.RVAL")
  field(INPQ, "XCOR:DOG:252:CONFIG.RVAL")
  field(INPR, "XCOR:DOG:252:HSTA")
  field(INPS, "XCOR:DOG:252:CTRL.RVAL")
  field(INPT, "XCOR:DOG:252:DEGAUSOK") 
  field(INPV, "XCOR:DOG:252:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:252:STAT")
}

record(longout, "XCOR:DOG:252:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "XCOR:DOG:252:STATCTRLSUB")
  field(DOL, "XCOR:DOG:252:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "XCOR:DOG:252:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "XCOR:DOG:252:STAT")
  field(INPB, "XCOR:DOG:252:HSTA")
  field(INPD, "XCOR:DOG:252:ONOFFCTRL.RVAL")
  field(FLNK, "XCOR:DOG:252:STATMSG")
}

record(mbbo, "XCOR:DOG:252:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:DOG:252:UNAVAILGO")
  field(DOL, "XCOR:DOG:252:STATCTRLSUB.W")
}

record(seq, "XCOR:DOG:252:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "XCOR:DOG:252:STATSUB.U")
  field(LNK1, "XCOR:DOG:252:UNAVAIL PP")
}

record(stringout, "XCOR:DOG:252:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"XCOR:DOG:252:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - XCOR:DOG:252:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - XCOR:DOG:252:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"XCOR:DOG:252STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - XCOR:DOG:252:STATUS\nC - XCOR:DOG:252:ON\nD - XCOR:DOG:252:STDZOK\nE - XCOR:DOG:252:CALBOK\nF - XCOR:DOG:252:BACTDRIFT (future)\nG -\nH- XCOR:DOG:252:DACSTATUS\nI -XCOR:DOG:252:ADCSTATUS\nJ - XCOR:DOG:252:BACTSTATUS\nK - XCOR:DOG:252:BDESSTATUS\nL - XCOR:DOG:252:RIPLSTATUS\n\nOutput:\nP - XCOR:DOG:252:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "XCOR:DOG:252:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "XCOR:DOG:252:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "XCOR:DOG:252:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "XCOR:DOG:252:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "YCOR:DOG:281:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:213:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:DOG:281:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "YCOR:DOG:281:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:213:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "YCOR:DOG:281:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "1")
  field(LOLO, "-1")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "YCOR:DOG:281:BDELTAS")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(DOL,  "YCOR:DOG:281:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "YCOR:DOG:281:ICTRL PP")
}

# This record is processed by YCOR:DOG:281:ICON")
# Note: we are not setting alarms here.
record(ao, "YCOR:DOG:281:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(DOL,  "YCOR:DOG:281:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:281:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "YCOR:DOG:281:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(HOPR, "1")
  field(LOPR, "-1")
}

record(ao, "YCOR:DOG:281:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(MDEL, "-1")
  field(FLNK, "YCOR:DOG:281:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "YCOR:DOG:281:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "YCOR:DOG:281:ISETPT.OMSL")

  field(DOL2, "YCOR:DOG:281:ICTRL")
  field(LNK2, "YCOR:DOG:281:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "YCOR:DOG:281:ISETPT.OMSL")
}

record(ao, "YCOR:DOG:281:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "1")
  field(FLNK, "YCOR:DOG:281:IMIN")
}

record(ao, "YCOR:DOG:281:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(VAL,  "-1")
  field(FLNK, "YCOR:DOG:281:IRANGE")
}

record(sel, "YCOR:DOG:281:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(NVL,  "YCOR:DOG:281:BACT.SEVR")
  field(INPA, "YCOR:DOG:281:IACT NPP MS")
  field(INPB, "YCOR:DOG:281:IACTPREVOK NPP MS")
  field(INPC, "YCOR:DOG:281:IACTPREVOK NPP MS")
  field(INPD, "YCOR:DOG:281:IACTPREVOK NPP MS")
}

record(sub, "YCOR:DOG:281:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:281:IDES")
  field(INPB, "YCOR:DOG:281:ISETPT.DRVH")
  field(INPC, "YCOR:DOG:281:ISETPT.DRVL")
  field(INPD, "YCOR:DOG:281:IDELTAS.I")
  field(INPE, "YCOR:DOG:281:IDELTAS.J")
  field(INPG, "YCOR:DOG:281:STATE")
  field(INPH, "YCOR:DOG:281:HSTA")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:DOG:281:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:281:IDES")
  field(INPB, "YCOR:DOG:281:ISETPT.DRVH")
  field(INPC, "YCOR:DOG:281:ISETPT.DRVL")
  field(INPD, "YCOR:DOG:281:IDELTAS.K")
  field(INPE, "YCOR:DOG:281:IDELTAS.L")
  field(INPG, "YCOR:DOG:281:STATE")
  field(INPH, "YCOR:DOG:281:HSTA")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:DOG:281:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "YCOR:DOG:281:BLIMITS")
  field(LNK1, "YCOR:DOG:281:IACTLIMITS.F PP")
  field(DOL2, "YCOR:DOG:281:IACTLIMITS.I")
  field(LNK2, "YCOR:DOG:281:IACT.HIGH")
  field(DOL3, "YCOR:DOG:281:IACTLIMITS.J")
  field(LNK3, "YCOR:DOG:281:IACT.LOW")
  field(DOL4, "YCOR:DOG:281:IACTLIMITS.K")
  field(LNK4, "YCOR:DOG:281:IACT.HIHI")
  field(DOL5, "YCOR:DOG:281:IACTLIMITS.L")
  field(LNK5, "YCOR:DOG:281:IACT.LOLO")
  field(DOL6, "YCOR:DOG:281:BLIMITS")
  field(LNK6, "YCOR:DOG:281:IMONLIMITS.F PP")
  field(DOL7, "YCOR:DOG:281:IMONLIMITS.I")
  field(LNK7, "YCOR:DOG:281:IMON.HIGH")
  field(DOL8, "YCOR:DOG:281:IMONLIMITS.J")
  field(LNK8, "YCOR:DOG:281:IMON.LOW")
  field(DOL9, "YCOR:DOG:281:IMONLIMITS.K")
  field(LNK9, "YCOR:DOG:281:IMON.HIHI")
  field(DOLA, "YCOR:DOG:281:IMONLIMITS.L")
  field(LNKA, "YCOR:DOG:281:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "YCOR:DOG:281:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "YCOR:DOG:281:TRIMBTOL")
  field(INPE, "YCOR:DOG:281:CHCKBTOL")
  field(INPF, "YCOR:DOG:281:BDELTAS.K")
  field(INPG, "YCOR:DOG:281:BDELTAS.L")
  field(INPH, "YCOR:DOG:281:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "YCOR:DOG:281:STDZITOLR")
  field(INPC, "YCOR:DOG:281:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:213:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "YCOR:DOG:281:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:213:RESET PP
#
record(bo, "YCOR:DOG:281:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:213:RESET PP")
}

record(bo, "YCOR:DOG:281:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:213:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "YCOR:DOG:281:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "YCOR:DOG:281:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:213:IRAMPRATE PP")
  field(FLNK, "YCOR:DOG:281:STDZDLY")
}


record(ao, "YCOR:DOG:281:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:213:ISETPT PP")
  field(DOL, "YCOR:DOG:281:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "YCOR:DOG:281:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:213:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:DOG:281:BMON")
}

record(ao, "YCOR:DOG:281:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:213:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "YCOR:DOG:281:IRIPLOK")
}

record(sub, "YCOR:DOG:281:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "YCOR:DOG:281:IRIPL.VAL")
  field(INPB, "YCOR:DOG:281:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:DOG:281:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:DOG:281:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "YCOR:DOG:281:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:213:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "YCOR:DOG:281:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:213:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "YCOR:DOG:281:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:DOG:281:IACTPREVOK")
  field(LNK2, "YCOR:DOG:281:IDIFF")
  field(LNK3, "YCOR:DOG:281:IADIFF")
  field(LNK4, "YCOR:DOG:281:IRATIO")
  field(LNK5, "YCOR:DOG:281:IDIRECT")
  field(LNK6, "YCOR:DOG:281:IACTPOL_CHECK")
}

record(calc, "YCOR:DOG:281:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:DOG:281:IDES")
  field(INPB, "YCOR:DOG:281:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1")
  field(LOPR, "-1")
}

record(calc, "YCOR:DOG:281:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "YCOR:DOG:281:IDIFF")
  field(PREC, "9")
}

record(calc, "YCOR:DOG:281:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:DOG:281:IDIFF")
  field(INPB, "YCOR:DOG:281:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "YCOR:DOG:281:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "YCOR:DOG:281:IMIN")
  field(INPB,   "YCOR:DOG:281:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "YCOR:DOG:281:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "YCOR:DOG:281:IACT")
  field(INPB, "YCOR:DOG:281:IDES")
  field(INPC, "YCOR:DOG:281:ISETPT")
  field(INPD, "YCOR:DOG:281:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "YCOR:DOG:281:IADJUST PP")
}

record(bo, "YCOR:DOG:281:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "YCOR:DOG:281:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "YCOR:DOG:281:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "YCOR:DOG:281:IACT")
  field(FLNK, "YCOR:DOG:281:IACTPOL")
}
record(bo, "YCOR:DOG:281:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:DOG:281:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"YCOR:DOG:281:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:DOG:281:IDELTAS and the\n  YCOR:DOG:281:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"YCOR:DOG:281:IACT: \n  Get copy of YCOR:DOG:281:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"YCOR:DOG:281:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"YCOR:DOG:281:IDES:\n  Contains raw value calculated by \nYCOR:DOG:281:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nYCOR:DOG:281:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"YCOR:DOG:281:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  YCOR:DOG:281:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               YCOR:DOG:281:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"YCOR:DOG:281:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by YCOR:DOG:281:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, YCOR:DOG:281:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  YCOR:DOG:281:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "YCOR:DOG:281:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:281:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:DOG:281:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:DOG:281:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:DOG:281:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "YCOR:DOG:281:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "YCOR:DOG:281:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "YCOR:DOG:281:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "YCOR:DOG:281:TRIMTYPE.RVAL")
  field(INPB,   "YCOR:DOG:281:CONFIG.RVAL")
  field(OUT,    "YCOR:DOG:281:TRIMMAXNUM PP")
}
record(longout, "YCOR:DOG:281:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "YCOR:DOG:281:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "YCOR:DOG:281:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "YCOR:DOG:281:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "YCOR:DOG:281:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "YCOR:DOG:281:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "YCOR:DOG:281:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "YCOR:DOG:281:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "YCOR:DOG:281:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "YCOR:DOG:281:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "YCOR:DOG:281:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "YCOR:DOG:281:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "YCOR:DOG:281:IMOVE")
 field(INPB, "YCOR:DOG:281:IACT")
 field(INPC, "YCOR:DOG:281:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "YCOR:DOG:281:TRIMDLYPCT")
 field(INPF, "YCOR:DOG:281:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "YCOR:DOG:281:RAMPTIME_LEFT PP")
}

record(longout, "YCOR:DOG:281:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "YCOR:DOG:281:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "YCOR:DOG:281:RAMPDONE_CALC")
}

record(calc, "YCOR:DOG:281:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "YCOR:DOG:281:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "YCOR:DOG:281:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "YCOR:DOG:281:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:DOG:281:RAMPTIME_LEFT")
 field(OUT,  "YCOR:DOG:281:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "YCOR:DOG:281:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:DOG:281:RAMPTIME_LEFT NMS")
 field(OUT,  "YCOR:DOG:281:RAMPDONE PP")
}

record(bo, "YCOR:DOG:281:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "YCOR:DOG:281:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "YCOR:DOG:281:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "YCOR:DOG:281:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:281:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "YCOR:DOG:281:DEBUG.PROC PP")
  field(LNK2, "YCOR:DOG:281:STDZCYCLENUM.PROC PP")
  field(LNK3, "YCOR:DOG:281:STDZDISABLE.PROC PP")
  field(LNK4, "YCOR:DOG:281:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "YCOR:DOG:281:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "YCOR:DOG:281:STDZIMIN NPP NMS")
  field(INPB, "YCOR:DOG:281:STDZIMAX NPP NMS")
  field(INPC, "YCOR:DOG:281:STDZIFINAL NPP NMS")
  field(INPD, "YCOR:DOG:281:STDZCYCLENUM NPP NMS")
  field(INPE, "YCOR:DOG:281:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "YCOR:DOG:281:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "YCOR:DOG:281:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "YCOR:DOG:281:STDZWF PP")
  field(OUTB, "YCOR:DOG:281:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "YCOR:DOG:281:STDZWF")
}

record(mbbo, "YCOR:DOG:281:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "YCOR:DOG:281:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "YCOR:DOG:281:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "YCOR:DOG:281:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "YCOR:DOG:281:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "YCOR:DOG:281:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "YCOR:DOG:281:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:DOG:281:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:DOG:281:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "YCOR:DOG:281:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:281:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "YCOR:DOG:281:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "YCOR:DOG:281:STDZIMIN")
}

record(ao, "YCOR:DOG:281:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL,  "-1")
  field(FLNK, "YCOR:DOG:281:STDZIMAX")
}

record(ao, "YCOR:DOG:281:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL,  "1")
  field(FLNK, "YCOR:DOG:281:STDZIFINAL")
}

record(ao, "YCOR:DOG:281:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL,  "-1")
  field(FLNK, "YCOR:DOG:281:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "YCOR:DOG:281:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "YCOR:DOG:281:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "YCOR:DOG:281:STDZIMIN CP NMS")
  field(INPB, "YCOR:DOG:281:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "YCOR:DOG:281:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "YCOR:DOG:281:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "YCOR:DOG:281:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "YCOR:DOG:281:STDZIMIN CP NMS")
  field(INPB, "YCOR:DOG:281:STDZIMAX CP NMS")
  field(INPC, "YCOR:DOG:281:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:281:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "YCOR:DOG:281:TRIMDLYPCT CP MS")
  field(INPB, "YCOR:DOG:281:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "YCOR:DOG:281:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "YCOR:DOG:281:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:281:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "YCOR:DOG:281:IDES.HOPR")
  field(INPB, "YCOR:DOG:281:STDZMINIPCT CPP NMS")
  field(INPC, "YCOR:DOG:281:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "YCOR:DOG:281:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "YCOR:DOG:281:IDES.HOPR")
  field(INPB, "YCOR:DOG:281:IDES.LOPR")
  field(INPC, "YCOR:DOG:281:STDZDIRECT.RVAL")
  field(INPD, "YCOR:DOG:281:STDZMINIDELTA")
  field(INPE, "YCOR:DOG:281:IDES")
  field(PREC, "5")
  field(FLNK, "YCOR:DOG:281:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "YCOR:DOG:281:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "YCOR:DOG:281:IDES.HOPR")
  field(INPB, "YCOR:DOG:281:IDES.LOPR")
  field(INPC, "YCOR:DOG:281:STDZDIRECT.RVAL")
  field(INPD, "YCOR:DOG:281:STDZMINIDELTA")
  field(INPE, "YCOR:DOG:281:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "YCOR:DOG:281:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "YCOR:DOG:281:IADJUST.RVAL")
  field(INPB, "YCOR:DOG:281:STDZDIRECT.RVAL")
  field(INPC, "YCOR:DOG:281:STDZOK.RVAL")
  field(INPD, "YCOR:DOG:281:STDZDISABLE.RVAL")
  field(INPE, "YCOR:DOG:281:STATE.RVAL CPP NMS")
  field(INPF, "YCOR:DOG:281:ICTRL.RVAL")
  field(INPG, "YCOR:DOG:281:STATE.SEVR")
  field(INPH, "YCOR:DOG:281:BDELTAS.M")
  field(INPI, "YCOR:DOG:281:IACT.SEVR")
  field(OUT,  "YCOR:DOG:281:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "YCOR:DOG:281:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "YCOR:DOG:281:STDZLOSTTOD.PROC")
  field(LNK2, "YCOR:DOG:281:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "YCOR:DOG:281:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:281:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:DOG:281:IACT CP")
  field(INPB, "YCOR:DOG:281:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "YCOR:DOG:281:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "YCOR:DOG:281:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:281:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:DOG:281:STDZIACTMAX")
  field(INPB, "YCOR:DOG:281:IACT")
  field(INPC, "YCOR:DOG:281:IDELTAS.I")
  field(OUT,  "YCOR:DOG:281:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "YCOR:DOG:281:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "YCOR:DOG:281:STDZOK.RVAL CP")
  field(INPB, "YCOR:DOG:281:STDZDISABLE.RVAL CP")
  field(INPC, "YCOR:DOG:281:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "YCOR:DOG:281:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "YCOR:DOG:281:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "YCOR:DOG:281:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "YCOR:DOG:281:CALBOK")
  field(INPB, "YCOR:DOG:281:CALBDISABLE")
  field(INPC, "YCOR:DOG:281:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "YCOR:DOG:281:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "YCOR:DOG:281:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "YCOR:DOG:281:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "YCOR:DOG:281:CALBSLOPE")
  field(DOL3, "YCOR:DOG:281:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "YCOR:DOG:281:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:281:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "YCOR:DOG:281:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "YCOR:DOG:281:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "YCOR:DOG:281:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "YCOR:DOG:281:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "YCOR:DOG:281:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:281:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "YCOR:DOG:281:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:281:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "YCOR:DOG:281:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "YCOR:DOG:281:IACT")
  field(INPD, "YCOR:DOG:281:DACSLOPE")
  field(INPE, "YCOR:DOG:281:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "YCOR:DOG:281:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "YCOR:DOG:281:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "1")
  field(HOPR, "1")
  field(DRVL, "-1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "YCOR:DOG:281:CALBIMAX")
}

record(ao, "YCOR:DOG:281:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "1")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVL, "-1")
  field(EGU,  "A")
  field(VAL,  "1")
  field(FLNK, "YCOR:DOG:281:CALBSTEPNUM")
}

record(ao, "YCOR:DOG:281:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL, "0")
}

record(longout, "YCOR:DOG:281:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:DOG:281:CALBIDELTA")
}

record(calc, "YCOR:DOG:281:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "YCOR:DOG:281:CALBIMAX")
  field(INPB, "YCOR:DOG:281:CALBIMIN")
  field(INPC, "YCOR:DOG:281:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "YCOR:DOG:281:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:213:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:213:IACT.HOPR")
  field(INPC, "YCOR:DOG:281:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "YCOR:DOG:281:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:DOG:281:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:281:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:281:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:281:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "YCOR:DOG:281:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:281:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:281:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:281:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "YCOR:DOG:281:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:281:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:281:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:281:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:DOG:281:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:281:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:281:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "YCOR:DOG:281:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:281:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "YCOR:DOG:281:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "YCOR:DOG:281:CALBSTEPNUM")
  field(INPB, "YCOR:DOG:281:CALBIACTWF")
  field(INPC, "YCOR:DOG:281:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "YCOR:DOG:281:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "YCOR:DOG:281:STDZITOL")

  field(INPH, "YCOR:DOG:281:DACSLOPE")
  field(INPI, "YCOR:DOG:281:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "YCOR:DOG:281:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "YCOR:DOG:281:CALBSTEPNUM")
  field(INPB, "YCOR:DOG:281:CALBIACTWF")
  field(INPC, "YCOR:DOG:281:DACWF")
  field(INPF, "YCOR:DOG:281:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe YCOR:DOG:281CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "YCOR:DOG:281:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "YCOR:DOG:281:DEGAUSIMIN.PROC PP")
  field(OUTB, "YCOR:DOG:281:DEGAUSIMAX.PROC PP")
  field(OUTC, "YCOR:DOG:281:DEGAUSTYPE.PROC PP")
  field(OUTD, "YCOR:DOG:281:DEGAUSSTEP.PROC PP")
  field(OUTE, "YCOR:DOG:281:MADNAME.PROC PP")
  field(OUTF, "YCOR:DOG:281:PSTYPE.PROC PP")
  field(OUTG, "YCOR:DOG:281:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "YCOR:DOG:281:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:DOG:281:DEGAUSIMIN NPP NMS")
  field(INPB, "YCOR:DOG:281:DEGAUSIMAX NPP NMS")
  field(INPC, "YCOR:DOG:281:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "YCOR:DOG:281:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "YCOR:DOG:281:PSTYPE NPP NMS")
  field(INPG, "YCOR:DOG:281:DEBUG.RVAL NPP NMS")
  field(INPH, "YCOR:DOG:281:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "YCOR:DOG:281:DEGAUSWF PP")
  field(OUTB, "YCOR:DOG:281:DEGAUSMSG PP")
  field(OUTC, "YCOR:DOG:281:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "YCOR:DOG:281:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"YCOR:DOG:281:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "YCOR:DOG:281:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "YCOR:DOG:281:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "YCOR:DOG:281:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "YCOR:DOG:281:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "YCOR:DOG:281:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(VAL,  "-1")
}
record(ao, "YCOR:DOG:281:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(VAL,  "1")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"YCOR:DOG:281:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "YCOR:DOG:281:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"YCOR:DOG:281:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "YCOR:DOG:281:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "YCOR:DOG:281:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "YCOR:DOG:281:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "YCOR:DOG:281:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:DOG:281:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:281:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:DOG:281:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:DOG:281:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "YCOR:DOG:281:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "YCOR:DOG:281:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "YCOR:DOG:281:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "YCOR:DOG:281:DEGAUS_IMAX")
  field(INPB, "YCOR:DOG:281:ISETPT")
  field(INPC, "YCOR:DOG:281:DEGAUSTYPE.RVAL")
  field(OUT,  "YCOR:DOG:281:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "YCOR:DOG:281:DEGAUS_IMAX_UPDATE")
}
record(seq, "YCOR:DOG:281:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "YCOR:DOG:281:ISETPT")
  field(LNK1, "YCOR:DOG:281:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "YCOR:DOG:281:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(VAL,  "1")
  field(FLNK, "YCOR:DOG:281:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "YCOR:DOG:281:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "YCOR:DOG:281:DEGAUS_IMAX")
  field(FLNK, "YCOR:DOG:281:DEGAUS_IMAXPOL")
}
record(bo, "YCOR:DOG:281:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:DOG:281:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "YCOR:DOG:281:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "YCOR:DOG:281:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "YCOR:DOG:281:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "1")
  field(LOPR, "-1")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "YCOR:DOG:281:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "YCOR:DOG:281:IACT")
  field(INPB, "YCOR:DOG:281:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "YCOR:DOG:281:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "YCOR:DOG:281:IACTPOL")
}
record(bo, "YCOR:DOG:281:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"YCOR:DOG:281:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "YCOR:DOG:281:DEGAUSENABLE CP")
  field(INPB, "YCOR:DOG:281:DEGAUSOK")
  field(INPC, "YCOR:DOG:281:STATE CP")
  field(INPD, "YCOR:DOG:281:STATE.SEVR")
  field(OUT,  "YCOR:DOG:281:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "YCOR:DOG:281:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "YCOR:DOG:281:DEGAUS_STATE_CHECK")
  field(LNK1, "YCOR:DOG:281:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "YCOR:DOG:281:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "YCOR:DOG:281:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "YCOR:DOG:281:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "YCOR:DOG:281:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "YCOR:DOG:281:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:DOG:281:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "YCOR:DOG:281:STATMSG.FRSV")
  field(LNK4, "YCOR:DOG:281:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:DOG:281:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:281:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:DOG:281:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "YCOR:DOG:281:STATMSG.FRSV")
  field(LNK4, "YCOR:DOG:281:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:DOG:281:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "YCOR:DOG:281:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "YCOR:DOG:281:STATMSG.FRSV")
  field(LNK3, "YCOR:DOG:281:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "YCOR:DOG:281:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:281:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "YCOR:DOG:281:STATMSG.FRSV PP")
  field(LNK3, "YCOR:DOG:281:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "YCOR:DOG:281:FUNC") {
  field(DESC, "YCOR:DOG:281 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "YCOR:DOG:281:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:DOG:281:CTRL") {
  field(DESC, "YCOR:DOG:281 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "YCOR:DOG:281:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "YCOR:DOG:281:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "YCOR:DOG:281:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "YCOR:DOG:281:BUSY") {
  field(DESC, "YCOR:DOG:281 Ctrl Done")
  field(DOL, "YCOR:DOG:281:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:281:SELECT")
}

record(bo, "YCOR:DOG:281:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "YCOR:DOG:281:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:DOG:281:CTRLSTATE") {
  field(DESC, "YCOR:DOG:281 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("YCOR:DOG:281:CTRL",20,20,0,0,"YCOR:DOG:281:CTRL")
#! Field("YCOR:DOG:281:CTRL.OUT",16777215,1,"YCOR:DOG:281:CTRL.OUT")
#! Link("YCOR:DOG:281:CTRL.OUT","YCOR:DOG:281:SELECTEN.A")
#! Field("YCOR:DOG:281:CTRL.VAL",16777215,1,"YCOR:DOG:281:CTRL.VAL")
#! Record("YCOR:DOG:281:SELECTEN",321,381,0,0,"YCOR:DOG:281:SELECTEN")
#! Field("YCOR:DOG:281:SELECTEN.A",16777215,0,"YCOR:DOG:281:SELECTEN.A")
#! Field("YCOR:DOG:281:SELECTEN.FLNK",16777215,1,"YCOR:DOG:281:SELECTEN.FLNK")
#! Link("YCOR:DOG:281:SELECTEN.FLNK","YCOR:DOG:281:BUSY")
#! Field("YCOR:DOG:281:SELECTEN.VAL",16777215,1,"YCOR:DOG:281:SELECTEN.VAL")
#! Record("YCOR:DOG:281:BUSY",623,274,0,0,"YCOR:DOG:281:BUSY")
#! Field("YCOR:DOG:281:BUSY.DOL",16777215,0,"YCOR:DOG:281:BUSY.DOL")
#! Link("YCOR:DOG:281:BUSY.DOL","YCOR:DOG:281:SELECTEN.VAL")
#! Field("YCOR:DOG:281:BUSY.FLNK",16777215,1,"YCOR:DOG:281:BUSY.FLNK")
#! Link("YCOR:DOG:281:BUSY.FLNK","YCOR:DOG:281:SELECT")
#! Record("YCOR:DOG:281:SELECT",669,508,0,1,"YCOR:DOG:281:SELECT")
#! Record("YCOR:DOG:281:FUNC",940,120,0,0,"YCOR:DOG:281:FUNC")
#! Field("YCOR:DOG:281:FUNC.OUT",16777215,0,"YCOR:DOG:281:FUNC.OUT")
#! Link("YCOR:DOG:281:FUNC.OUT","YCOR:DOG:281:CTRL.VAL")
#! Record("YCOR:DOG:281:ABORT",193,41,0,0,"YCOR:DOG:281:ABORT")
#! Record("YCOR:DOG:281:CTRLSTATE",369,34,0,0,"YCOR:DOG:281:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"YCOR:DOG:281:SELECT is used for Multi-device selection.\nIt is enabled when associated YCOR:DOG:281:CTRL is \"0\" (DONE).\nIt is disabled when associated YCOR:DOG:281:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"YCOR:DOG:281:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "YCOR:DOG:281:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "YCOR:DOG:281:BCTRL.SEVR")
  field(OUT,  "YCOR:DOG:281:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "YCOR:DOG:281:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:DOG:281:BACT")
  field(INPB, "YCOR:DOG:281:POLYCOEF")
  field(INPC, "YCOR:DOG:281:POLYCOEF.A")
  field(INPD, "YCOR:DOG:281:POLYCOEF.B")
  field(INPE, "YCOR:DOG:281:IACT MS")
  field(INPF, "YCOR:DOG:281:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(HIHI, "0.01049318")
  field(LOLO, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.01049318")
  field(LOW,  "-0.01049318")
  field(FLNK, "YCOR:DOG:281:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "YCOR:DOG:281:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:DOG:281:BDES")
  field(INPB, "YCOR:DOG:281:TRIMBTOL")
  field(INPC, "YCOR:DOG:281:TRIMBTOLR")
  field(INPD, "YCOR:DOG:281:CHCKBTOL")
  field(INPE, "YCOR:DOG:281:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "YCOR:DOG:281:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "YCOR:DOG:281:MPSBTOL")
  field(INPQ, "YCOR:DOG:281:MPSBTOLR")
  field(FLNK, "YCOR:DOG:281:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "YCOR:DOG:281:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "YCOR:DOG:281:BDES")
  field(INPB, "YCOR:DOG:281:BDELTAS.I")
  field(INPG, "YCOR:DOG:281:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "YCOR:DOG:281:BCON.HIGH")
  field(OUTB, "YCOR:DOG:281:BCON.LOW")
  field(OUTC, "YCOR:DOG:281:BCON.HIHI")
  field(OUTD, "YCOR:DOG:281:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:281:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "YCOR:DOG:281:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:DOG:281:BDIFF")
  field(LNK2, "YCOR:DOG:281:BADIFF")
  field(LNK3, "YCOR:DOG:281:BRATIO")
  field(LNK4, "YCOR:DOG:281:MPSLIMITS")
  field(LNK5, "YCOR:DOG:281:I2BSTATUS")
  field(LNK6, "YCOR:DOG:281:IACTFO.PROC")
}

record(calc, "YCOR:DOG:281:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:DOG:281:BDES")
  field(INPB, "YCOR:DOG:281:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "YCOR:DOG:281:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "YCOR:DOG:281:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "YCOR:DOG:281:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:DOG:281:BDIFF")
  field(INPB, "YCOR:DOG:281:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "YCOR:DOG:281:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "YCOR:DOG:281:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "YCOR:DOG:281:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:DOG:281:BMON")
  field(INPB, "YCOR:DOG:281:POLYCOEF")
  field(INPC, "YCOR:DOG:281:POLYCOEF.A")
  field(INPD, "YCOR:DOG:281:POLYCOEF.B")
  field(INPE, "YCOR:DOG:281:IMON MS")
  field(INPF, "YCOR:DOG:281:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(HIHI, "0.01049318")
  field(LOLO, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.01049318")
  field(LOW,  "-0.01049318")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:213:BDES CP
record(ao,  "YCOR:DOG:281:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.01049318")
   field(DRVL, "-0.01049318")
   field(HOPR, "0.01049318")
   field(LOPR, "-0.01049318")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "YCOR:DOG:281:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "YCOR:DOG:281:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:281:POLYCOEF")
  field(INPC, "YCOR:DOG:281:POLYCOEF.A")
  field(INPD, "YCOR:DOG:281:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(MDEL, "-1")
  field(INPE, "YCOR:DOG:281:BDES.DRVH")
  field(INPF, "YCOR:DOG:281:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:281:IDES")
}
record(sub, "YCOR:DOG:281:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:281:POLYCOEF")
  field(INPC, "YCOR:DOG:281:POLYCOEF.A")
  field(INPD, "YCOR:DOG:281:POLYCOEF.B")
  field(INPE, "YCOR:DOG:281:BDES.DRVH")
  field(INPF, "YCOR:DOG:281:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "YCOR:DOG:281:INOM")
}

record(sub, "YCOR:DOG:281:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:281:BDES.VAL")
  field(INPB, "YCOR:DOG:281:BDES.DRVH")
  field(INPC, "YCOR:DOG:281:BDES.DRVL")
  field(INPD, "YCOR:DOG:281:BDELTAS.I")
  field(INPE, "YCOR:DOG:281:BDELTAS.J")
  field(INPG, "YCOR:DOG:281:STATE")
  field(INPH, "YCOR:DOG:281:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:DOG:281:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:281:BDES.VAL")
  field(INPB, "YCOR:DOG:281:BDES.DRVH")
  field(INPC, "YCOR:DOG:281:BDES.DRVL")
  field(INPD, "YCOR:DOG:281:BDELTAS.K")
  field(INPE, "YCOR:DOG:281:BDELTAS.L")
  field(INPG, "YCOR:DOG:281:STATE")
  field(INPH, "YCOR:DOG:281:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:DOG:281:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "YCOR:DOG:281:BLIMITS")
  field(LNK1, "YCOR:DOG:281:BACTLIMITS.F PP")
  field(DOL2, "YCOR:DOG:281:BACTLIMITS.I")
  field(LNK2, "YCOR:DOG:281:BACT.HIGH")
  field(DOL3, "YCOR:DOG:281:BACTLIMITS.J")
  field(LNK3, "YCOR:DOG:281:BACT.LOW")
  field(DOL4, "YCOR:DOG:281:BACTLIMITS.K")
  field(LNK4, "YCOR:DOG:281:BACT.HIHI")
  field(DOL5, "YCOR:DOG:281:BACTLIMITS.L")
  field(LNK5, "YCOR:DOG:281:BACT.LOLO")
  field(DOL6, "YCOR:DOG:281:BLIMITS")
  field(LNK6, "YCOR:DOG:281:BMONLIMITS.F PP")
  field(DOL7, "YCOR:DOG:281:BMONLIMITS.I")
  field(LNK7, "YCOR:DOG:281:BMON.HIGH")
  field(DOL8, "YCOR:DOG:281:BMONLIMITS.J")
  field(LNK8, "YCOR:DOG:281:BMON.LOW")
  field(DOL9, "YCOR:DOG:281:BMONLIMITS.K")
  field(LNK9, "YCOR:DOG:281:BMON.HIHI")
  field(DOLA, "YCOR:DOG:281:BMONLIMITS.L")
  field(LNKA, "YCOR:DOG:281:BMON.LOLO")
  field(FLNK, "YCOR:DOG:281:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "YCOR:DOG:281:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "YCOR:DOG:281:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "YCOR:DOG:281:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:281:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "YCOR:DOG:281:BCTRL.VAL")
  field(LNK2, "YCOR:DOG:281:BDES PP")

  field(DOL3, "1")
  field(LNK3, "YCOR:DOG:281:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "YCOR:DOG:281:CHECKSTDZLOST.PROC PP")

  field(DOL5, "YCOR:DOG:281:BCTRL.VAL")
  field(LNK5, "YCOR:DOG:281:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "YCOR:DOG:281:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "YCOR:DOG:281:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:281:POLYCOEF")
  field(INPC, "YCOR:DOG:281:POLYCOEF.A")
  field(INPD, "YCOR:DOG:281:POLYCOEF.B")
  field(INPE, "YCOR:DOG:281:BDES.DRVH")
  field(INPF, "YCOR:DOG:281:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:281:ISETPT")
}

record(ao, "YCOR:DOG:281:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "YCOR:DOG:281:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "YCL2P")
}

record(ai, "YCOR:DOG:281:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "772.153175")
}

record(ao, "YCOR:DOG:281:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU, "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.01049318")
  field(FLNK, "YCOR:DOG:281:BSTEP")
}

record(ao, "YCOR:DOG:281:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU, "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(FLNK, "YCOR:DOG:281:BSTEP")
}

record(ao, "YCOR:DOG:281:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by YCOR:DOG:281:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "YCOR:DOG:281:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "YCOR:DOG:281:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "YCOR:DOG:281:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:281:POLYCOEF")
  field(INPC, "YCOR:DOG:281:POLYCOEF.A")
  field(INPD, "YCOR:DOG:281:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(MDEL, "-1")
  field(INPE, "YCOR:DOG:281:BCON.DRVH")
  field(INPF, "YCOR:DOG:281:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:281:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "YCOR:DOG:281:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "YCOR:DOG:281:BMAX")
  field(INPB, "YCOR:DOG:281:BMIN")
  field(INPC, "YCOR:DOG:281:BMIN.SEVR")
  field(INPD, "YCOR:DOG:281:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"YCOR:DOG:281:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "YCOR:DOG:281:ONLINE CP")
  field(OUT,  "YCOR:DOG:281:BCTRLDISABLEFOUT PP")
}

record(fanout, "YCOR:DOG:281:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "YCOR:DOG:281:BCTRLDISABLECALC")
  field(LNK1, "YCOR:DOG:281:BCTRLDISABLE")
  field(LNK2, "YCOR:DOG:281:BCTRLENABLE")
}

record(stringout, "YCOR:DOG:281:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:DOG:281:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "YCOR:DOG:281:BCTRLDISV_UPDATE")
}

record(stringout, "YCOR:DOG:281:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:DOG:281:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "YCOR:DOG:281:BCTRLDISV_UPDATE")
}

record(calcout, "YCOR:DOG:281:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "YCOR:DOG:281:ONLINE")
  field(OUT,  "YCOR:DOG:281:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"YCOR:DOG:281:BACT and MON\n  are processed via links from \n  YCOR:DOG:281:IACT (device raw value readback 1)\n  and\n  YCOR:DOG:281:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from YCOR:DOG:281:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = YCOR:DOG:281:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"YCOR:DOG:281:BDES\n  is processed when set by CA users or \n  YCOR:DOG:281:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"YCOR:DOG:281:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  YCOR:DOG:281:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (YCOR:DOG:281:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"YCOR:DOG:281:B*LIMITS and YCOR:DOG:281:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:DOG:281:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"YCOR:DOG:281:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"YCOR:DOG:281:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "YCOR:DOG:281:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:281:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "YCOR:DOG:281:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "YCOR:DOG:281:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:281:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:281:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:281:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "YCOR:DOG:281:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "YCOR:DOG:281:MPSLIMITS.E PP")
}

record(aSub, "YCOR:DOG:281:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "YCOR:DOG:281:MPS.RVAL")
  field(INPB, "YCOR:DOG:281:BADIFF")
  field(INPC, "YCOR:DOG:281:BDELTAS.N")
  field(INPD, "YCOR:DOG:281:BACT")
  field(INPE, "YCOR:DOG:281:MPSBITMASK.RVAL")
  field(INPF, "YCOR:DOG:281:MPSBLLIM")
  field(INPG, "YCOR:DOG:281:MPSBMIN")
  field(INPH, "YCOR:DOG:281:MPSBMAX")
  field(INPI, "YCOR:DOG:281:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "YCOR:DOG:281:INTOL.RVAL PP")
  field(OUTB, "YCOR:DOG:281:INTOL_BMIN.RVAL PP")
  field(OUTC, "YCOR:DOG:281:INTOL_BRANGE.RVAL PP")
  field(OUTD, "YCOR:DOG:281:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "YCOR:DOG:281:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:281:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:281:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:281:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:281:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:281:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:281:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:281:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "YCOR:DOG:281:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "YCOR:DOG:281:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:DOG:281:CHCKBTOL")
  field(INPB, "YCOR:DOG:281:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "YCOR:DOG:281:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "YCOR:DOG:281:CHCKBTOL")
  field(FLNK, "YCOR:DOG:281:CHCKITOL")
}

record(calc, "YCOR:DOG:281:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "YCOR:DOG:281:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "YCOR:DOG:281:BDES.HOPR")
  field(INPB, "YCOR:DOG:281:STABILITY")
  field(INPC, "YCOR:DOG:281:BDES.LOPR")
}

record(longout, "YCOR:DOG:281:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "YCOR:DOG:281:CHCKBTOL")
}

record(calc, "YCOR:DOG:281:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:DOG:281:POLYCOEF.B")
  field(INPB, "YCOR:DOG:281:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "YCOR:DOG:281:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "YCOR:DOG:281:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "YCOR:DOG:281:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "YCOR:DOG:281:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "YCOR:DOG:281:PAUGO")  
}

record(fanout, "YCOR:DOG:281:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "YCOR:DOG:281:PAUSTOP")
  field(LNK2, "YCOR:DOG:281:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "YCOR:DOG:281:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "YCOR:DOG:281:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:213:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:213:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "YCOR:DOG:281:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "YCOR:DOG:281:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:213:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:213:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "YCOR:DOG:281:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:213:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:DOG:281:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "YCOR:DOG:281:PSTYPE.RVAL")
  field(INPC, "YCOR:DOG:281:TURNEDOFF.RVAL")
  field(INPD, "YCOR:DOG:281:CONFIG.RVAL")
  field(INPE, "YCOR:DOG:281:PSCATEGORY.RVAL")
  field(INPF, "YCOR:DOG:281:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "YCOR:DOG:281:AUTOCTRL.RVAL")
  field(INPJ, "YCOR:DOG:281:OUTOFSERVICE.RVAL")
  field(INPL, "YCOR:DOG:281:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "YCOR:DOG:281:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "YCOR:DOG:281:PAU")
  field(INPP, "YCOR:DOG:281:CALBDISABLE.RVAL")
  field(INPQ, "YCOR:DOG:281:PTRBDISABLE.RVAL")
  field(INPR, "YCOR:DOG:281:TRIMDISABLE.RVAL")
  field(INPS, "YCOR:DOG:281:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "YCOR:DOG:281:FBCK")
  field(INPU, "YCOR:DOG:281:TRIMTYPE.RVAL")
  field(INPV, "YCOR:DOG:281:STDZDIRECT.RVAL")
  field(INPW, "YCOR:DOG:281:DEGAUSENABLE.RVAL")
  field(FLNK, "YCOR:DOG:281:HSTA")
}

record(longin, "YCOR:DOG:281:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "YCOR:DOG:281:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "YCOR:DOG:281:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "YCOR:DOG:281:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "YCOR:DOG:281:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:281:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:281:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:281:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by YCOR:DOG:281:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses YCOR:DOG:281:FBCK.
# This PV should be replaced by YCOR:DOG:281:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "YCOR:DOG:281:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "YCOR:DOG:281:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:DOG:281:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:281:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"YCOR:DOG:281:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "YCOR:DOG:281:OUTOFSERVICE NPP NMS")
  field(OUT,  "YCOR:DOG:281:ONLINE PP")
}
record(bo, "YCOR:DOG:281:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "YCOR:DOG:281:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:DOG:281:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "YCOR:DOG:281:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "YCOR:DOG:281:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "YCOR:DOG:281:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "YCOR:DOG:281:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "YCOR:DOG:281:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "YCOR:DOG:281:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:281:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:281:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:281:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "YCOR:DOG:281:TRIMTYPE")
}

record(stringout, "YCOR:DOG:281:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "YCOR:DOG:281:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "YCOR:DOG:281:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "YCOR:DOG:281:STATE.RVAL")
  field(INPB, "YCOR:DOG:281:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:DOG:281:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:DOG:281:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "YCOR:DOG:281:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "YCOR:DOG:281:STATE.RVAL")
  field(INPB, "YCOR:DOG:281:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:DOG:281:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:DOG:281:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "YCOR:DOG:281:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "YCOR:DOG:281:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "YCOR:DOG:281:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "YCOR:DOG:281:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "YCOR:DOG:281:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"YCOR:DOG:281:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("YCOR:DOG:281:TURNEDOFF",3140,1907,0,1,"YCOR:DOG:281:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:DOG:281:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "YCOR:DOG:281:BACT.STAT")
  field(INPB, "YCOR:DOG:281:BDES.STAT")
  field(INPC, "YCOR:DOG:281:IRIPL.STAT")
  field(INPD, "MCOR:EXT:213:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:213:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "YCOR:DOG:281:BACT.SEVR")
  field(INPH, "YCOR:DOG:281:BDES.SEVR")
  field(INPI, "YCOR:DOG:281:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:213:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:213:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "YCOR:DOG:281:STATE.RVAL")
  field(INPN, "YCOR:DOG:281:STDZOK")
  field(INPO, "YCOR:DOG:281:CALBOK")
  field(INPP, "YCOR:DOG:281:OUTOFSERVICE.RVAL")
  field(INPQ, "YCOR:DOG:281:CONFIG.RVAL")
  field(INPR, "YCOR:DOG:281:HSTA")
  field(INPS, "YCOR:DOG:281:CTRL.RVAL")
  field(INPT, "YCOR:DOG:281:DEGAUSOK") 
  field(INPV, "YCOR:DOG:281:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:281:STAT")
}

record(longout, "YCOR:DOG:281:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "YCOR:DOG:281:STATCTRLSUB")
  field(DOL, "YCOR:DOG:281:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "YCOR:DOG:281:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "YCOR:DOG:281:STAT")
  field(INPB, "YCOR:DOG:281:HSTA")
  field(INPD, "YCOR:DOG:281:ONOFFCTRL.RVAL")
  field(FLNK, "YCOR:DOG:281:STATMSG")
}

record(mbbo, "YCOR:DOG:281:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:DOG:281:UNAVAILGO")
  field(DOL, "YCOR:DOG:281:STATCTRLSUB.W")
}

record(seq, "YCOR:DOG:281:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "YCOR:DOG:281:STATSUB.U")
  field(LNK1, "YCOR:DOG:281:UNAVAIL PP")
}

record(stringout, "YCOR:DOG:281:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"YCOR:DOG:281:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - YCOR:DOG:281:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - YCOR:DOG:281:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"YCOR:DOG:281STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - YCOR:DOG:281:STATUS\nC - YCOR:DOG:281:ON\nD - YCOR:DOG:281:STDZOK\nE - YCOR:DOG:281:CALBOK\nF - YCOR:DOG:281:BACTDRIFT (future)\nG -\nH- YCOR:DOG:281:DACSTATUS\nI -YCOR:DOG:281:ADCSTATUS\nJ - YCOR:DOG:281:BACTSTATUS\nK - YCOR:DOG:281:BDESSTATUS\nL - YCOR:DOG:281:RIPLSTATUS\n\nOutput:\nP - YCOR:DOG:281:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "YCOR:DOG:281:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "YCOR:DOG:281:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "YCOR:DOG:281:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "YCOR:DOG:281:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "XCOR:DOG:338:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:214:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:DOG:338:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "XCOR:DOG:338:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:214:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "XCOR:DOG:338:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "1")
  field(LOLO, "-1")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "XCOR:DOG:338:BDELTAS")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(DOL,  "XCOR:DOG:338:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "XCOR:DOG:338:ICTRL PP")
}

# This record is processed by XCOR:DOG:338:ICON")
# Note: we are not setting alarms here.
record(ao, "XCOR:DOG:338:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(DOL,  "XCOR:DOG:338:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:338:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "XCOR:DOG:338:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(HOPR, "1")
  field(LOPR, "-1")
}

record(ao, "XCOR:DOG:338:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(MDEL, "-1")
  field(FLNK, "XCOR:DOG:338:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "XCOR:DOG:338:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "XCOR:DOG:338:ISETPT.OMSL")

  field(DOL2, "XCOR:DOG:338:ICTRL")
  field(LNK2, "XCOR:DOG:338:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "XCOR:DOG:338:ISETPT.OMSL")
}

record(ao, "XCOR:DOG:338:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "1")
  field(FLNK, "XCOR:DOG:338:IMIN")
}

record(ao, "XCOR:DOG:338:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(VAL,  "-1")
  field(FLNK, "XCOR:DOG:338:IRANGE")
}

record(sel, "XCOR:DOG:338:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(NVL,  "XCOR:DOG:338:BACT.SEVR")
  field(INPA, "XCOR:DOG:338:IACT NPP MS")
  field(INPB, "XCOR:DOG:338:IACTPREVOK NPP MS")
  field(INPC, "XCOR:DOG:338:IACTPREVOK NPP MS")
  field(INPD, "XCOR:DOG:338:IACTPREVOK NPP MS")
}

record(sub, "XCOR:DOG:338:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:338:IDES")
  field(INPB, "XCOR:DOG:338:ISETPT.DRVH")
  field(INPC, "XCOR:DOG:338:ISETPT.DRVL")
  field(INPD, "XCOR:DOG:338:IDELTAS.I")
  field(INPE, "XCOR:DOG:338:IDELTAS.J")
  field(INPG, "XCOR:DOG:338:STATE")
  field(INPH, "XCOR:DOG:338:HSTA")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:DOG:338:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:338:IDES")
  field(INPB, "XCOR:DOG:338:ISETPT.DRVH")
  field(INPC, "XCOR:DOG:338:ISETPT.DRVL")
  field(INPD, "XCOR:DOG:338:IDELTAS.K")
  field(INPE, "XCOR:DOG:338:IDELTAS.L")
  field(INPG, "XCOR:DOG:338:STATE")
  field(INPH, "XCOR:DOG:338:HSTA")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:DOG:338:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "XCOR:DOG:338:BLIMITS")
  field(LNK1, "XCOR:DOG:338:IACTLIMITS.F PP")
  field(DOL2, "XCOR:DOG:338:IACTLIMITS.I")
  field(LNK2, "XCOR:DOG:338:IACT.HIGH")
  field(DOL3, "XCOR:DOG:338:IACTLIMITS.J")
  field(LNK3, "XCOR:DOG:338:IACT.LOW")
  field(DOL4, "XCOR:DOG:338:IACTLIMITS.K")
  field(LNK4, "XCOR:DOG:338:IACT.HIHI")
  field(DOL5, "XCOR:DOG:338:IACTLIMITS.L")
  field(LNK5, "XCOR:DOG:338:IACT.LOLO")
  field(DOL6, "XCOR:DOG:338:BLIMITS")
  field(LNK6, "XCOR:DOG:338:IMONLIMITS.F PP")
  field(DOL7, "XCOR:DOG:338:IMONLIMITS.I")
  field(LNK7, "XCOR:DOG:338:IMON.HIGH")
  field(DOL8, "XCOR:DOG:338:IMONLIMITS.J")
  field(LNK8, "XCOR:DOG:338:IMON.LOW")
  field(DOL9, "XCOR:DOG:338:IMONLIMITS.K")
  field(LNK9, "XCOR:DOG:338:IMON.HIHI")
  field(DOLA, "XCOR:DOG:338:IMONLIMITS.L")
  field(LNKA, "XCOR:DOG:338:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "XCOR:DOG:338:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "XCOR:DOG:338:TRIMBTOL")
  field(INPE, "XCOR:DOG:338:CHCKBTOL")
  field(INPF, "XCOR:DOG:338:BDELTAS.K")
  field(INPG, "XCOR:DOG:338:BDELTAS.L")
  field(INPH, "XCOR:DOG:338:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "XCOR:DOG:338:STDZITOLR")
  field(INPC, "XCOR:DOG:338:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:214:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "XCOR:DOG:338:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:214:RESET PP
#
record(bo, "XCOR:DOG:338:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:214:RESET PP")
}

record(bo, "XCOR:DOG:338:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:214:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "XCOR:DOG:338:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "XCOR:DOG:338:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:214:IRAMPRATE PP")
  field(FLNK, "XCOR:DOG:338:STDZDLY")
}


record(ao, "XCOR:DOG:338:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:214:ISETPT PP")
  field(DOL, "XCOR:DOG:338:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "XCOR:DOG:338:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:214:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:DOG:338:BMON")
}

record(ao, "XCOR:DOG:338:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:214:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "XCOR:DOG:338:IRIPLOK")
}

record(sub, "XCOR:DOG:338:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "XCOR:DOG:338:IRIPL.VAL")
  field(INPB, "XCOR:DOG:338:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:DOG:338:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:DOG:338:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "XCOR:DOG:338:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:214:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "XCOR:DOG:338:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:214:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "XCOR:DOG:338:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:DOG:338:IACTPREVOK")
  field(LNK2, "XCOR:DOG:338:IDIFF")
  field(LNK3, "XCOR:DOG:338:IADIFF")
  field(LNK4, "XCOR:DOG:338:IRATIO")
  field(LNK5, "XCOR:DOG:338:IDIRECT")
  field(LNK6, "XCOR:DOG:338:IACTPOL_CHECK")
}

record(calc, "XCOR:DOG:338:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:DOG:338:IDES")
  field(INPB, "XCOR:DOG:338:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1")
  field(LOPR, "-1")
}

record(calc, "XCOR:DOG:338:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "XCOR:DOG:338:IDIFF")
  field(PREC, "9")
}

record(calc, "XCOR:DOG:338:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:DOG:338:IDIFF")
  field(INPB, "XCOR:DOG:338:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "XCOR:DOG:338:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "XCOR:DOG:338:IMIN")
  field(INPB,   "XCOR:DOG:338:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "XCOR:DOG:338:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "XCOR:DOG:338:IACT")
  field(INPB, "XCOR:DOG:338:IDES")
  field(INPC, "XCOR:DOG:338:ISETPT")
  field(INPD, "XCOR:DOG:338:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "XCOR:DOG:338:IADJUST PP")
}

record(bo, "XCOR:DOG:338:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "XCOR:DOG:338:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "XCOR:DOG:338:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "XCOR:DOG:338:IACT")
  field(FLNK, "XCOR:DOG:338:IACTPOL")
}
record(bo, "XCOR:DOG:338:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:DOG:338:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"XCOR:DOG:338:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:DOG:338:IDELTAS and the\n  XCOR:DOG:338:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"XCOR:DOG:338:IACT: \n  Get copy of XCOR:DOG:338:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"XCOR:DOG:338:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"XCOR:DOG:338:IDES:\n  Contains raw value calculated by \nXCOR:DOG:338:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nXCOR:DOG:338:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"XCOR:DOG:338:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  XCOR:DOG:338:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               XCOR:DOG:338:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"XCOR:DOG:338:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by XCOR:DOG:338:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, XCOR:DOG:338:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  XCOR:DOG:338:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "XCOR:DOG:338:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:338:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:DOG:338:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:DOG:338:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:DOG:338:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "XCOR:DOG:338:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "XCOR:DOG:338:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "XCOR:DOG:338:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "XCOR:DOG:338:TRIMTYPE.RVAL")
  field(INPB,   "XCOR:DOG:338:CONFIG.RVAL")
  field(OUT,    "XCOR:DOG:338:TRIMMAXNUM PP")
}
record(longout, "XCOR:DOG:338:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "XCOR:DOG:338:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "XCOR:DOG:338:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "XCOR:DOG:338:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "XCOR:DOG:338:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "XCOR:DOG:338:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "XCOR:DOG:338:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "XCOR:DOG:338:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "XCOR:DOG:338:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "XCOR:DOG:338:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "XCOR:DOG:338:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "XCOR:DOG:338:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "XCOR:DOG:338:IMOVE")
 field(INPB, "XCOR:DOG:338:IACT")
 field(INPC, "XCOR:DOG:338:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "XCOR:DOG:338:TRIMDLYPCT")
 field(INPF, "XCOR:DOG:338:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "XCOR:DOG:338:RAMPTIME_LEFT PP")
}

record(longout, "XCOR:DOG:338:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "XCOR:DOG:338:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "XCOR:DOG:338:RAMPDONE_CALC")
}

record(calc, "XCOR:DOG:338:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "XCOR:DOG:338:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "XCOR:DOG:338:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "XCOR:DOG:338:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:DOG:338:RAMPTIME_LEFT")
 field(OUT,  "XCOR:DOG:338:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "XCOR:DOG:338:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:DOG:338:RAMPTIME_LEFT NMS")
 field(OUT,  "XCOR:DOG:338:RAMPDONE PP")
}

record(bo, "XCOR:DOG:338:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "XCOR:DOG:338:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "XCOR:DOG:338:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "XCOR:DOG:338:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:338:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "XCOR:DOG:338:DEBUG.PROC PP")
  field(LNK2, "XCOR:DOG:338:STDZCYCLENUM.PROC PP")
  field(LNK3, "XCOR:DOG:338:STDZDISABLE.PROC PP")
  field(LNK4, "XCOR:DOG:338:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "XCOR:DOG:338:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "XCOR:DOG:338:STDZIMIN NPP NMS")
  field(INPB, "XCOR:DOG:338:STDZIMAX NPP NMS")
  field(INPC, "XCOR:DOG:338:STDZIFINAL NPP NMS")
  field(INPD, "XCOR:DOG:338:STDZCYCLENUM NPP NMS")
  field(INPE, "XCOR:DOG:338:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "XCOR:DOG:338:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "XCOR:DOG:338:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "XCOR:DOG:338:STDZWF PP")
  field(OUTB, "XCOR:DOG:338:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "XCOR:DOG:338:STDZWF")
}

record(mbbo, "XCOR:DOG:338:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "XCOR:DOG:338:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "XCOR:DOG:338:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "XCOR:DOG:338:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "XCOR:DOG:338:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "XCOR:DOG:338:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "XCOR:DOG:338:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:DOG:338:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:DOG:338:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "XCOR:DOG:338:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:338:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "XCOR:DOG:338:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "XCOR:DOG:338:STDZIMIN")
}

record(ao, "XCOR:DOG:338:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL,  "-1")
  field(FLNK, "XCOR:DOG:338:STDZIMAX")
}

record(ao, "XCOR:DOG:338:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL,  "1")
  field(FLNK, "XCOR:DOG:338:STDZIFINAL")
}

record(ao, "XCOR:DOG:338:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL,  "-1")
  field(FLNK, "XCOR:DOG:338:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "XCOR:DOG:338:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "XCOR:DOG:338:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "XCOR:DOG:338:STDZIMIN CP NMS")
  field(INPB, "XCOR:DOG:338:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "XCOR:DOG:338:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "XCOR:DOG:338:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "XCOR:DOG:338:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "XCOR:DOG:338:STDZIMIN CP NMS")
  field(INPB, "XCOR:DOG:338:STDZIMAX CP NMS")
  field(INPC, "XCOR:DOG:338:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:338:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "XCOR:DOG:338:TRIMDLYPCT CP MS")
  field(INPB, "XCOR:DOG:338:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "XCOR:DOG:338:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "XCOR:DOG:338:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:338:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "XCOR:DOG:338:IDES.HOPR")
  field(INPB, "XCOR:DOG:338:STDZMINIPCT CPP NMS")
  field(INPC, "XCOR:DOG:338:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "XCOR:DOG:338:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "XCOR:DOG:338:IDES.HOPR")
  field(INPB, "XCOR:DOG:338:IDES.LOPR")
  field(INPC, "XCOR:DOG:338:STDZDIRECT.RVAL")
  field(INPD, "XCOR:DOG:338:STDZMINIDELTA")
  field(INPE, "XCOR:DOG:338:IDES")
  field(PREC, "5")
  field(FLNK, "XCOR:DOG:338:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "XCOR:DOG:338:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "XCOR:DOG:338:IDES.HOPR")
  field(INPB, "XCOR:DOG:338:IDES.LOPR")
  field(INPC, "XCOR:DOG:338:STDZDIRECT.RVAL")
  field(INPD, "XCOR:DOG:338:STDZMINIDELTA")
  field(INPE, "XCOR:DOG:338:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "XCOR:DOG:338:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "XCOR:DOG:338:IADJUST.RVAL")
  field(INPB, "XCOR:DOG:338:STDZDIRECT.RVAL")
  field(INPC, "XCOR:DOG:338:STDZOK.RVAL")
  field(INPD, "XCOR:DOG:338:STDZDISABLE.RVAL")
  field(INPE, "XCOR:DOG:338:STATE.RVAL CPP NMS")
  field(INPF, "XCOR:DOG:338:ICTRL.RVAL")
  field(INPG, "XCOR:DOG:338:STATE.SEVR")
  field(INPH, "XCOR:DOG:338:BDELTAS.M")
  field(INPI, "XCOR:DOG:338:IACT.SEVR")
  field(OUT,  "XCOR:DOG:338:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "XCOR:DOG:338:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "XCOR:DOG:338:STDZLOSTTOD.PROC")
  field(LNK2, "XCOR:DOG:338:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "XCOR:DOG:338:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:338:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:DOG:338:IACT CP")
  field(INPB, "XCOR:DOG:338:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "XCOR:DOG:338:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "XCOR:DOG:338:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:338:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:DOG:338:STDZIACTMAX")
  field(INPB, "XCOR:DOG:338:IACT")
  field(INPC, "XCOR:DOG:338:IDELTAS.I")
  field(OUT,  "XCOR:DOG:338:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "XCOR:DOG:338:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "XCOR:DOG:338:STDZOK.RVAL CP")
  field(INPB, "XCOR:DOG:338:STDZDISABLE.RVAL CP")
  field(INPC, "XCOR:DOG:338:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "XCOR:DOG:338:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "XCOR:DOG:338:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "XCOR:DOG:338:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "XCOR:DOG:338:CALBOK")
  field(INPB, "XCOR:DOG:338:CALBDISABLE")
  field(INPC, "XCOR:DOG:338:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "XCOR:DOG:338:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "XCOR:DOG:338:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "XCOR:DOG:338:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "XCOR:DOG:338:CALBSLOPE")
  field(DOL3, "XCOR:DOG:338:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "XCOR:DOG:338:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:338:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "XCOR:DOG:338:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "XCOR:DOG:338:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "XCOR:DOG:338:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "XCOR:DOG:338:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "XCOR:DOG:338:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:338:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "XCOR:DOG:338:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:338:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "XCOR:DOG:338:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "XCOR:DOG:338:IACT")
  field(INPD, "XCOR:DOG:338:DACSLOPE")
  field(INPE, "XCOR:DOG:338:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "XCOR:DOG:338:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "XCOR:DOG:338:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "1")
  field(HOPR, "1")
  field(DRVL, "-1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "XCOR:DOG:338:CALBIMAX")
}

record(ao, "XCOR:DOG:338:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "1")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVL, "-1")
  field(EGU,  "A")
  field(VAL,  "1")
  field(FLNK, "XCOR:DOG:338:CALBSTEPNUM")
}

record(ao, "XCOR:DOG:338:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL, "0")
}

record(longout, "XCOR:DOG:338:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:DOG:338:CALBIDELTA")
}

record(calc, "XCOR:DOG:338:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "XCOR:DOG:338:CALBIMAX")
  field(INPB, "XCOR:DOG:338:CALBIMIN")
  field(INPC, "XCOR:DOG:338:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "XCOR:DOG:338:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:214:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:214:IACT.HOPR")
  field(INPC, "XCOR:DOG:338:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "XCOR:DOG:338:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:DOG:338:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:338:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:338:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:338:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "XCOR:DOG:338:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:338:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:338:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:338:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "XCOR:DOG:338:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:338:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:338:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:338:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:DOG:338:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:338:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:338:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "XCOR:DOG:338:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:338:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "XCOR:DOG:338:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "XCOR:DOG:338:CALBSTEPNUM")
  field(INPB, "XCOR:DOG:338:CALBIACTWF")
  field(INPC, "XCOR:DOG:338:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "XCOR:DOG:338:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "XCOR:DOG:338:STDZITOL")

  field(INPH, "XCOR:DOG:338:DACSLOPE")
  field(INPI, "XCOR:DOG:338:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "XCOR:DOG:338:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "XCOR:DOG:338:CALBSTEPNUM")
  field(INPB, "XCOR:DOG:338:CALBIACTWF")
  field(INPC, "XCOR:DOG:338:DACWF")
  field(INPF, "XCOR:DOG:338:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe XCOR:DOG:338CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "XCOR:DOG:338:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "XCOR:DOG:338:DEGAUSIMIN.PROC PP")
  field(OUTB, "XCOR:DOG:338:DEGAUSIMAX.PROC PP")
  field(OUTC, "XCOR:DOG:338:DEGAUSTYPE.PROC PP")
  field(OUTD, "XCOR:DOG:338:DEGAUSSTEP.PROC PP")
  field(OUTE, "XCOR:DOG:338:MADNAME.PROC PP")
  field(OUTF, "XCOR:DOG:338:PSTYPE.PROC PP")
  field(OUTG, "XCOR:DOG:338:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "XCOR:DOG:338:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:DOG:338:DEGAUSIMIN NPP NMS")
  field(INPB, "XCOR:DOG:338:DEGAUSIMAX NPP NMS")
  field(INPC, "XCOR:DOG:338:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "XCOR:DOG:338:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "XCOR:DOG:338:PSTYPE NPP NMS")
  field(INPG, "XCOR:DOG:338:DEBUG.RVAL NPP NMS")
  field(INPH, "XCOR:DOG:338:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "XCOR:DOG:338:DEGAUSWF PP")
  field(OUTB, "XCOR:DOG:338:DEGAUSMSG PP")
  field(OUTC, "XCOR:DOG:338:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "XCOR:DOG:338:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"XCOR:DOG:338:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "XCOR:DOG:338:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "XCOR:DOG:338:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "XCOR:DOG:338:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "XCOR:DOG:338:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "XCOR:DOG:338:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(VAL,  "-1")
}
record(ao, "XCOR:DOG:338:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(VAL,  "1")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"XCOR:DOG:338:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "XCOR:DOG:338:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"XCOR:DOG:338:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "XCOR:DOG:338:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "XCOR:DOG:338:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "XCOR:DOG:338:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "XCOR:DOG:338:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:DOG:338:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:338:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:DOG:338:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:DOG:338:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "XCOR:DOG:338:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "XCOR:DOG:338:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "XCOR:DOG:338:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "XCOR:DOG:338:DEGAUS_IMAX")
  field(INPB, "XCOR:DOG:338:ISETPT")
  field(INPC, "XCOR:DOG:338:DEGAUSTYPE.RVAL")
  field(OUT,  "XCOR:DOG:338:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "XCOR:DOG:338:DEGAUS_IMAX_UPDATE")
}
record(seq, "XCOR:DOG:338:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "XCOR:DOG:338:ISETPT")
  field(LNK1, "XCOR:DOG:338:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "XCOR:DOG:338:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(VAL,  "1")
  field(FLNK, "XCOR:DOG:338:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "XCOR:DOG:338:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "XCOR:DOG:338:DEGAUS_IMAX")
  field(FLNK, "XCOR:DOG:338:DEGAUS_IMAXPOL")
}
record(bo, "XCOR:DOG:338:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:DOG:338:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "XCOR:DOG:338:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "XCOR:DOG:338:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "XCOR:DOG:338:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "1")
  field(LOPR, "-1")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "XCOR:DOG:338:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "XCOR:DOG:338:IACT")
  field(INPB, "XCOR:DOG:338:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "XCOR:DOG:338:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "XCOR:DOG:338:IACTPOL")
}
record(bo, "XCOR:DOG:338:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"XCOR:DOG:338:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "XCOR:DOG:338:DEGAUSENABLE CP")
  field(INPB, "XCOR:DOG:338:DEGAUSOK")
  field(INPC, "XCOR:DOG:338:STATE CP")
  field(INPD, "XCOR:DOG:338:STATE.SEVR")
  field(OUT,  "XCOR:DOG:338:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "XCOR:DOG:338:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "XCOR:DOG:338:DEGAUS_STATE_CHECK")
  field(LNK1, "XCOR:DOG:338:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "XCOR:DOG:338:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "XCOR:DOG:338:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "XCOR:DOG:338:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "XCOR:DOG:338:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "XCOR:DOG:338:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:DOG:338:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "XCOR:DOG:338:STATMSG.FRSV")
  field(LNK4, "XCOR:DOG:338:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:DOG:338:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:338:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:DOG:338:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "XCOR:DOG:338:STATMSG.FRSV")
  field(LNK4, "XCOR:DOG:338:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:DOG:338:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "XCOR:DOG:338:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "XCOR:DOG:338:STATMSG.FRSV")
  field(LNK3, "XCOR:DOG:338:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "XCOR:DOG:338:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:338:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "XCOR:DOG:338:STATMSG.FRSV PP")
  field(LNK3, "XCOR:DOG:338:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "XCOR:DOG:338:FUNC") {
  field(DESC, "XCOR:DOG:338 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "XCOR:DOG:338:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:DOG:338:CTRL") {
  field(DESC, "XCOR:DOG:338 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "XCOR:DOG:338:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "XCOR:DOG:338:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "XCOR:DOG:338:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "XCOR:DOG:338:BUSY") {
  field(DESC, "XCOR:DOG:338 Ctrl Done")
  field(DOL, "XCOR:DOG:338:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:338:SELECT")
}

record(bo, "XCOR:DOG:338:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "XCOR:DOG:338:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:DOG:338:CTRLSTATE") {
  field(DESC, "XCOR:DOG:338 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("XCOR:DOG:338:CTRL",20,20,0,0,"XCOR:DOG:338:CTRL")
#! Field("XCOR:DOG:338:CTRL.OUT",16777215,1,"XCOR:DOG:338:CTRL.OUT")
#! Link("XCOR:DOG:338:CTRL.OUT","XCOR:DOG:338:SELECTEN.A")
#! Field("XCOR:DOG:338:CTRL.VAL",16777215,1,"XCOR:DOG:338:CTRL.VAL")
#! Record("XCOR:DOG:338:SELECTEN",321,381,0,0,"XCOR:DOG:338:SELECTEN")
#! Field("XCOR:DOG:338:SELECTEN.A",16777215,0,"XCOR:DOG:338:SELECTEN.A")
#! Field("XCOR:DOG:338:SELECTEN.FLNK",16777215,1,"XCOR:DOG:338:SELECTEN.FLNK")
#! Link("XCOR:DOG:338:SELECTEN.FLNK","XCOR:DOG:338:BUSY")
#! Field("XCOR:DOG:338:SELECTEN.VAL",16777215,1,"XCOR:DOG:338:SELECTEN.VAL")
#! Record("XCOR:DOG:338:BUSY",623,274,0,0,"XCOR:DOG:338:BUSY")
#! Field("XCOR:DOG:338:BUSY.DOL",16777215,0,"XCOR:DOG:338:BUSY.DOL")
#! Link("XCOR:DOG:338:BUSY.DOL","XCOR:DOG:338:SELECTEN.VAL")
#! Field("XCOR:DOG:338:BUSY.FLNK",16777215,1,"XCOR:DOG:338:BUSY.FLNK")
#! Link("XCOR:DOG:338:BUSY.FLNK","XCOR:DOG:338:SELECT")
#! Record("XCOR:DOG:338:SELECT",669,508,0,1,"XCOR:DOG:338:SELECT")
#! Record("XCOR:DOG:338:FUNC",940,120,0,0,"XCOR:DOG:338:FUNC")
#! Field("XCOR:DOG:338:FUNC.OUT",16777215,0,"XCOR:DOG:338:FUNC.OUT")
#! Link("XCOR:DOG:338:FUNC.OUT","XCOR:DOG:338:CTRL.VAL")
#! Record("XCOR:DOG:338:ABORT",193,41,0,0,"XCOR:DOG:338:ABORT")
#! Record("XCOR:DOG:338:CTRLSTATE",369,34,0,0,"XCOR:DOG:338:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"XCOR:DOG:338:SELECT is used for Multi-device selection.\nIt is enabled when associated XCOR:DOG:338:CTRL is \"0\" (DONE).\nIt is disabled when associated XCOR:DOG:338:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"XCOR:DOG:338:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "XCOR:DOG:338:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "XCOR:DOG:338:BCTRL.SEVR")
  field(OUT,  "XCOR:DOG:338:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "XCOR:DOG:338:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:DOG:338:BACT")
  field(INPB, "XCOR:DOG:338:POLYCOEF")
  field(INPC, "XCOR:DOG:338:POLYCOEF.A")
  field(INPD, "XCOR:DOG:338:POLYCOEF.B")
  field(INPE, "XCOR:DOG:338:IACT MS")
  field(INPF, "XCOR:DOG:338:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(HIHI, "0.01049318")
  field(LOLO, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.01049318")
  field(LOW,  "-0.01049318")
  field(FLNK, "XCOR:DOG:338:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "XCOR:DOG:338:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:DOG:338:BDES")
  field(INPB, "XCOR:DOG:338:TRIMBTOL")
  field(INPC, "XCOR:DOG:338:TRIMBTOLR")
  field(INPD, "XCOR:DOG:338:CHCKBTOL")
  field(INPE, "XCOR:DOG:338:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "XCOR:DOG:338:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "XCOR:DOG:338:MPSBTOL")
  field(INPQ, "XCOR:DOG:338:MPSBTOLR")
  field(FLNK, "XCOR:DOG:338:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "XCOR:DOG:338:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "XCOR:DOG:338:BDES")
  field(INPB, "XCOR:DOG:338:BDELTAS.I")
  field(INPG, "XCOR:DOG:338:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "XCOR:DOG:338:BCON.HIGH")
  field(OUTB, "XCOR:DOG:338:BCON.LOW")
  field(OUTC, "XCOR:DOG:338:BCON.HIHI")
  field(OUTD, "XCOR:DOG:338:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:338:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "XCOR:DOG:338:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:DOG:338:BDIFF")
  field(LNK2, "XCOR:DOG:338:BADIFF")
  field(LNK3, "XCOR:DOG:338:BRATIO")
  field(LNK4, "XCOR:DOG:338:MPSLIMITS")
  field(LNK5, "XCOR:DOG:338:I2BSTATUS")
  field(LNK6, "XCOR:DOG:338:IACTFO.PROC")
}

record(calc, "XCOR:DOG:338:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:DOG:338:BDES")
  field(INPB, "XCOR:DOG:338:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "XCOR:DOG:338:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "XCOR:DOG:338:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "XCOR:DOG:338:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:DOG:338:BDIFF")
  field(INPB, "XCOR:DOG:338:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "XCOR:DOG:338:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "XCOR:DOG:338:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "XCOR:DOG:338:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:DOG:338:BMON")
  field(INPB, "XCOR:DOG:338:POLYCOEF")
  field(INPC, "XCOR:DOG:338:POLYCOEF.A")
  field(INPD, "XCOR:DOG:338:POLYCOEF.B")
  field(INPE, "XCOR:DOG:338:IMON MS")
  field(INPF, "XCOR:DOG:338:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(HIHI, "0.01049318")
  field(LOLO, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.01049318")
  field(LOW,  "-0.01049318")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:214:BDES CP
record(ao,  "XCOR:DOG:338:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.01049318")
   field(DRVL, "-0.01049318")
   field(HOPR, "0.01049318")
   field(LOPR, "-0.01049318")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "XCOR:DOG:338:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "XCOR:DOG:338:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:338:POLYCOEF")
  field(INPC, "XCOR:DOG:338:POLYCOEF.A")
  field(INPD, "XCOR:DOG:338:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(MDEL, "-1")
  field(INPE, "XCOR:DOG:338:BDES.DRVH")
  field(INPF, "XCOR:DOG:338:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:338:IDES")
}
record(sub, "XCOR:DOG:338:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:338:POLYCOEF")
  field(INPC, "XCOR:DOG:338:POLYCOEF.A")
  field(INPD, "XCOR:DOG:338:POLYCOEF.B")
  field(INPE, "XCOR:DOG:338:BDES.DRVH")
  field(INPF, "XCOR:DOG:338:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "XCOR:DOG:338:INOM")
}

record(sub, "XCOR:DOG:338:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:338:BDES.VAL")
  field(INPB, "XCOR:DOG:338:BDES.DRVH")
  field(INPC, "XCOR:DOG:338:BDES.DRVL")
  field(INPD, "XCOR:DOG:338:BDELTAS.I")
  field(INPE, "XCOR:DOG:338:BDELTAS.J")
  field(INPG, "XCOR:DOG:338:STATE")
  field(INPH, "XCOR:DOG:338:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:DOG:338:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:338:BDES.VAL")
  field(INPB, "XCOR:DOG:338:BDES.DRVH")
  field(INPC, "XCOR:DOG:338:BDES.DRVL")
  field(INPD, "XCOR:DOG:338:BDELTAS.K")
  field(INPE, "XCOR:DOG:338:BDELTAS.L")
  field(INPG, "XCOR:DOG:338:STATE")
  field(INPH, "XCOR:DOG:338:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:DOG:338:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "XCOR:DOG:338:BLIMITS")
  field(LNK1, "XCOR:DOG:338:BACTLIMITS.F PP")
  field(DOL2, "XCOR:DOG:338:BACTLIMITS.I")
  field(LNK2, "XCOR:DOG:338:BACT.HIGH")
  field(DOL3, "XCOR:DOG:338:BACTLIMITS.J")
  field(LNK3, "XCOR:DOG:338:BACT.LOW")
  field(DOL4, "XCOR:DOG:338:BACTLIMITS.K")
  field(LNK4, "XCOR:DOG:338:BACT.HIHI")
  field(DOL5, "XCOR:DOG:338:BACTLIMITS.L")
  field(LNK5, "XCOR:DOG:338:BACT.LOLO")
  field(DOL6, "XCOR:DOG:338:BLIMITS")
  field(LNK6, "XCOR:DOG:338:BMONLIMITS.F PP")
  field(DOL7, "XCOR:DOG:338:BMONLIMITS.I")
  field(LNK7, "XCOR:DOG:338:BMON.HIGH")
  field(DOL8, "XCOR:DOG:338:BMONLIMITS.J")
  field(LNK8, "XCOR:DOG:338:BMON.LOW")
  field(DOL9, "XCOR:DOG:338:BMONLIMITS.K")
  field(LNK9, "XCOR:DOG:338:BMON.HIHI")
  field(DOLA, "XCOR:DOG:338:BMONLIMITS.L")
  field(LNKA, "XCOR:DOG:338:BMON.LOLO")
  field(FLNK, "XCOR:DOG:338:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "XCOR:DOG:338:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "XCOR:DOG:338:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "XCOR:DOG:338:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:338:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "XCOR:DOG:338:BCTRL.VAL")
  field(LNK2, "XCOR:DOG:338:BDES PP")

  field(DOL3, "1")
  field(LNK3, "XCOR:DOG:338:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "XCOR:DOG:338:CHECKSTDZLOST.PROC PP")

  field(DOL5, "XCOR:DOG:338:BCTRL.VAL")
  field(LNK5, "XCOR:DOG:338:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "XCOR:DOG:338:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "XCOR:DOG:338:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:338:POLYCOEF")
  field(INPC, "XCOR:DOG:338:POLYCOEF.A")
  field(INPD, "XCOR:DOG:338:POLYCOEF.B")
  field(INPE, "XCOR:DOG:338:BDES.DRVH")
  field(INPF, "XCOR:DOG:338:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:338:ISETPT")
}

record(ao, "XCOR:DOG:338:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "XCOR:DOG:338:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "XCL3P")
}

record(ai, "XCOR:DOG:338:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "806.896775")
}

record(ao, "XCOR:DOG:338:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU, "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.01049318")
  field(FLNK, "XCOR:DOG:338:BSTEP")
}

record(ao, "XCOR:DOG:338:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU, "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(FLNK, "XCOR:DOG:338:BSTEP")
}

record(ao, "XCOR:DOG:338:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by XCOR:DOG:338:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "XCOR:DOG:338:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "XCOR:DOG:338:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "XCOR:DOG:338:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:338:POLYCOEF")
  field(INPC, "XCOR:DOG:338:POLYCOEF.A")
  field(INPD, "XCOR:DOG:338:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(MDEL, "-1")
  field(INPE, "XCOR:DOG:338:BCON.DRVH")
  field(INPF, "XCOR:DOG:338:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:338:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "XCOR:DOG:338:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "XCOR:DOG:338:BMAX")
  field(INPB, "XCOR:DOG:338:BMIN")
  field(INPC, "XCOR:DOG:338:BMIN.SEVR")
  field(INPD, "XCOR:DOG:338:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"XCOR:DOG:338:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "XCOR:DOG:338:ONLINE CP")
  field(OUT,  "XCOR:DOG:338:BCTRLDISABLEFOUT PP")
}

record(fanout, "XCOR:DOG:338:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "XCOR:DOG:338:BCTRLDISABLECALC")
  field(LNK1, "XCOR:DOG:338:BCTRLDISABLE")
  field(LNK2, "XCOR:DOG:338:BCTRLENABLE")
}

record(stringout, "XCOR:DOG:338:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:DOG:338:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "XCOR:DOG:338:BCTRLDISV_UPDATE")
}

record(stringout, "XCOR:DOG:338:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:DOG:338:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "XCOR:DOG:338:BCTRLDISV_UPDATE")
}

record(calcout, "XCOR:DOG:338:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "XCOR:DOG:338:ONLINE")
  field(OUT,  "XCOR:DOG:338:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"XCOR:DOG:338:BACT and MON\n  are processed via links from \n  XCOR:DOG:338:IACT (device raw value readback 1)\n  and\n  XCOR:DOG:338:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from XCOR:DOG:338:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = XCOR:DOG:338:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"XCOR:DOG:338:BDES\n  is processed when set by CA users or \n  XCOR:DOG:338:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"XCOR:DOG:338:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  XCOR:DOG:338:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (XCOR:DOG:338:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"XCOR:DOG:338:B*LIMITS and XCOR:DOG:338:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:DOG:338:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"XCOR:DOG:338:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"XCOR:DOG:338:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "XCOR:DOG:338:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:338:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "XCOR:DOG:338:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "XCOR:DOG:338:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:338:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:338:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:338:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "XCOR:DOG:338:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "XCOR:DOG:338:MPSLIMITS.E PP")
}

record(aSub, "XCOR:DOG:338:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "XCOR:DOG:338:MPS.RVAL")
  field(INPB, "XCOR:DOG:338:BADIFF")
  field(INPC, "XCOR:DOG:338:BDELTAS.N")
  field(INPD, "XCOR:DOG:338:BACT")
  field(INPE, "XCOR:DOG:338:MPSBITMASK.RVAL")
  field(INPF, "XCOR:DOG:338:MPSBLLIM")
  field(INPG, "XCOR:DOG:338:MPSBMIN")
  field(INPH, "XCOR:DOG:338:MPSBMAX")
  field(INPI, "XCOR:DOG:338:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "XCOR:DOG:338:INTOL.RVAL PP")
  field(OUTB, "XCOR:DOG:338:INTOL_BMIN.RVAL PP")
  field(OUTC, "XCOR:DOG:338:INTOL_BRANGE.RVAL PP")
  field(OUTD, "XCOR:DOG:338:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "XCOR:DOG:338:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:338:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:338:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:338:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:338:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:338:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:338:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:338:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "XCOR:DOG:338:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "XCOR:DOG:338:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:DOG:338:CHCKBTOL")
  field(INPB, "XCOR:DOG:338:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "XCOR:DOG:338:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "XCOR:DOG:338:CHCKBTOL")
  field(FLNK, "XCOR:DOG:338:CHCKITOL")
}

record(calc, "XCOR:DOG:338:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "XCOR:DOG:338:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "XCOR:DOG:338:BDES.HOPR")
  field(INPB, "XCOR:DOG:338:STABILITY")
  field(INPC, "XCOR:DOG:338:BDES.LOPR")
}

record(longout, "XCOR:DOG:338:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "XCOR:DOG:338:CHCKBTOL")
}

record(calc, "XCOR:DOG:338:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:DOG:338:POLYCOEF.B")
  field(INPB, "XCOR:DOG:338:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "XCOR:DOG:338:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "XCOR:DOG:338:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "XCOR:DOG:338:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "XCOR:DOG:338:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "XCOR:DOG:338:PAUGO")  
}

record(fanout, "XCOR:DOG:338:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "XCOR:DOG:338:PAUSTOP")
  field(LNK2, "XCOR:DOG:338:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "XCOR:DOG:338:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "XCOR:DOG:338:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:214:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:214:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "XCOR:DOG:338:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "XCOR:DOG:338:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:214:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:214:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "XCOR:DOG:338:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:214:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:DOG:338:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "XCOR:DOG:338:PSTYPE.RVAL")
  field(INPC, "XCOR:DOG:338:TURNEDOFF.RVAL")
  field(INPD, "XCOR:DOG:338:CONFIG.RVAL")
  field(INPE, "XCOR:DOG:338:PSCATEGORY.RVAL")
  field(INPF, "XCOR:DOG:338:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "XCOR:DOG:338:AUTOCTRL.RVAL")
  field(INPJ, "XCOR:DOG:338:OUTOFSERVICE.RVAL")
  field(INPL, "XCOR:DOG:338:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "XCOR:DOG:338:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "XCOR:DOG:338:PAU")
  field(INPP, "XCOR:DOG:338:CALBDISABLE.RVAL")
  field(INPQ, "XCOR:DOG:338:PTRBDISABLE.RVAL")
  field(INPR, "XCOR:DOG:338:TRIMDISABLE.RVAL")
  field(INPS, "XCOR:DOG:338:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "XCOR:DOG:338:FBCK")
  field(INPU, "XCOR:DOG:338:TRIMTYPE.RVAL")
  field(INPV, "XCOR:DOG:338:STDZDIRECT.RVAL")
  field(INPW, "XCOR:DOG:338:DEGAUSENABLE.RVAL")
  field(FLNK, "XCOR:DOG:338:HSTA")
}

record(longin, "XCOR:DOG:338:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "XCOR:DOG:338:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "XCOR:DOG:338:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "XCOR:DOG:338:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "XCOR:DOG:338:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:338:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:338:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:338:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by XCOR:DOG:338:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses XCOR:DOG:338:FBCK.
# This PV should be replaced by XCOR:DOG:338:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "XCOR:DOG:338:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "XCOR:DOG:338:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:DOG:338:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:338:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"XCOR:DOG:338:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "XCOR:DOG:338:OUTOFSERVICE NPP NMS")
  field(OUT,  "XCOR:DOG:338:ONLINE PP")
}
record(bo, "XCOR:DOG:338:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "XCOR:DOG:338:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:DOG:338:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "XCOR:DOG:338:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "XCOR:DOG:338:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "XCOR:DOG:338:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "XCOR:DOG:338:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "XCOR:DOG:338:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "XCOR:DOG:338:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:338:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:338:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:338:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "XCOR:DOG:338:TRIMTYPE")
}

record(stringout, "XCOR:DOG:338:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "XCOR:DOG:338:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "XCOR:DOG:338:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "XCOR:DOG:338:STATE.RVAL")
  field(INPB, "XCOR:DOG:338:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:DOG:338:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:DOG:338:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "XCOR:DOG:338:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "XCOR:DOG:338:STATE.RVAL")
  field(INPB, "XCOR:DOG:338:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:DOG:338:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:DOG:338:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "XCOR:DOG:338:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "XCOR:DOG:338:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "XCOR:DOG:338:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "XCOR:DOG:338:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "XCOR:DOG:338:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"XCOR:DOG:338:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("XCOR:DOG:338:TURNEDOFF",3140,1907,0,1,"XCOR:DOG:338:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:DOG:338:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "XCOR:DOG:338:BACT.STAT")
  field(INPB, "XCOR:DOG:338:BDES.STAT")
  field(INPC, "XCOR:DOG:338:IRIPL.STAT")
  field(INPD, "MCOR:EXT:214:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:214:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "XCOR:DOG:338:BACT.SEVR")
  field(INPH, "XCOR:DOG:338:BDES.SEVR")
  field(INPI, "XCOR:DOG:338:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:214:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:214:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "XCOR:DOG:338:STATE.RVAL")
  field(INPN, "XCOR:DOG:338:STDZOK")
  field(INPO, "XCOR:DOG:338:CALBOK")
  field(INPP, "XCOR:DOG:338:OUTOFSERVICE.RVAL")
  field(INPQ, "XCOR:DOG:338:CONFIG.RVAL")
  field(INPR, "XCOR:DOG:338:HSTA")
  field(INPS, "XCOR:DOG:338:CTRL.RVAL")
  field(INPT, "XCOR:DOG:338:DEGAUSOK") 
  field(INPV, "XCOR:DOG:338:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:338:STAT")
}

record(longout, "XCOR:DOG:338:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "XCOR:DOG:338:STATCTRLSUB")
  field(DOL, "XCOR:DOG:338:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "XCOR:DOG:338:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "XCOR:DOG:338:STAT")
  field(INPB, "XCOR:DOG:338:HSTA")
  field(INPD, "XCOR:DOG:338:ONOFFCTRL.RVAL")
  field(FLNK, "XCOR:DOG:338:STATMSG")
}

record(mbbo, "XCOR:DOG:338:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:DOG:338:UNAVAILGO")
  field(DOL, "XCOR:DOG:338:STATCTRLSUB.W")
}

record(seq, "XCOR:DOG:338:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "XCOR:DOG:338:STATSUB.U")
  field(LNK1, "XCOR:DOG:338:UNAVAIL PP")
}

record(stringout, "XCOR:DOG:338:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"XCOR:DOG:338:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - XCOR:DOG:338:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - XCOR:DOG:338:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"XCOR:DOG:338STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - XCOR:DOG:338:STATUS\nC - XCOR:DOG:338:ON\nD - XCOR:DOG:338:STDZOK\nE - XCOR:DOG:338:CALBOK\nF - XCOR:DOG:338:BACTDRIFT (future)\nG -\nH- XCOR:DOG:338:DACSTATUS\nI -XCOR:DOG:338:ADCSTATUS\nJ - XCOR:DOG:338:BACTSTATUS\nK - XCOR:DOG:338:BDESSTATUS\nL - XCOR:DOG:338:RIPLSTATUS\n\nOutput:\nP - XCOR:DOG:338:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "XCOR:DOG:338:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "XCOR:DOG:338:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "XCOR:DOG:338:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "XCOR:DOG:338:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "YCOR:DOG:357:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:215:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:DOG:357:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "YCOR:DOG:357:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:215:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "YCOR:DOG:357:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "1")
  field(LOLO, "-1")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "YCOR:DOG:357:BDELTAS")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(DOL,  "YCOR:DOG:357:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "YCOR:DOG:357:ICTRL PP")
}

# This record is processed by YCOR:DOG:357:ICON")
# Note: we are not setting alarms here.
record(ao, "YCOR:DOG:357:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(DOL,  "YCOR:DOG:357:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:357:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "YCOR:DOG:357:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(HOPR, "1")
  field(LOPR, "-1")
}

record(ao, "YCOR:DOG:357:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(MDEL, "-1")
  field(FLNK, "YCOR:DOG:357:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "YCOR:DOG:357:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "YCOR:DOG:357:ISETPT.OMSL")

  field(DOL2, "YCOR:DOG:357:ICTRL")
  field(LNK2, "YCOR:DOG:357:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "YCOR:DOG:357:ISETPT.OMSL")
}

record(ao, "YCOR:DOG:357:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "1")
  field(FLNK, "YCOR:DOG:357:IMIN")
}

record(ao, "YCOR:DOG:357:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(VAL,  "-1")
  field(FLNK, "YCOR:DOG:357:IRANGE")
}

record(sel, "YCOR:DOG:357:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(NVL,  "YCOR:DOG:357:BACT.SEVR")
  field(INPA, "YCOR:DOG:357:IACT NPP MS")
  field(INPB, "YCOR:DOG:357:IACTPREVOK NPP MS")
  field(INPC, "YCOR:DOG:357:IACTPREVOK NPP MS")
  field(INPD, "YCOR:DOG:357:IACTPREVOK NPP MS")
}

record(sub, "YCOR:DOG:357:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:357:IDES")
  field(INPB, "YCOR:DOG:357:ISETPT.DRVH")
  field(INPC, "YCOR:DOG:357:ISETPT.DRVL")
  field(INPD, "YCOR:DOG:357:IDELTAS.I")
  field(INPE, "YCOR:DOG:357:IDELTAS.J")
  field(INPG, "YCOR:DOG:357:STATE")
  field(INPH, "YCOR:DOG:357:HSTA")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:DOG:357:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:357:IDES")
  field(INPB, "YCOR:DOG:357:ISETPT.DRVH")
  field(INPC, "YCOR:DOG:357:ISETPT.DRVL")
  field(INPD, "YCOR:DOG:357:IDELTAS.K")
  field(INPE, "YCOR:DOG:357:IDELTAS.L")
  field(INPG, "YCOR:DOG:357:STATE")
  field(INPH, "YCOR:DOG:357:HSTA")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:DOG:357:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "YCOR:DOG:357:BLIMITS")
  field(LNK1, "YCOR:DOG:357:IACTLIMITS.F PP")
  field(DOL2, "YCOR:DOG:357:IACTLIMITS.I")
  field(LNK2, "YCOR:DOG:357:IACT.HIGH")
  field(DOL3, "YCOR:DOG:357:IACTLIMITS.J")
  field(LNK3, "YCOR:DOG:357:IACT.LOW")
  field(DOL4, "YCOR:DOG:357:IACTLIMITS.K")
  field(LNK4, "YCOR:DOG:357:IACT.HIHI")
  field(DOL5, "YCOR:DOG:357:IACTLIMITS.L")
  field(LNK5, "YCOR:DOG:357:IACT.LOLO")
  field(DOL6, "YCOR:DOG:357:BLIMITS")
  field(LNK6, "YCOR:DOG:357:IMONLIMITS.F PP")
  field(DOL7, "YCOR:DOG:357:IMONLIMITS.I")
  field(LNK7, "YCOR:DOG:357:IMON.HIGH")
  field(DOL8, "YCOR:DOG:357:IMONLIMITS.J")
  field(LNK8, "YCOR:DOG:357:IMON.LOW")
  field(DOL9, "YCOR:DOG:357:IMONLIMITS.K")
  field(LNK9, "YCOR:DOG:357:IMON.HIHI")
  field(DOLA, "YCOR:DOG:357:IMONLIMITS.L")
  field(LNKA, "YCOR:DOG:357:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "YCOR:DOG:357:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "YCOR:DOG:357:TRIMBTOL")
  field(INPE, "YCOR:DOG:357:CHCKBTOL")
  field(INPF, "YCOR:DOG:357:BDELTAS.K")
  field(INPG, "YCOR:DOG:357:BDELTAS.L")
  field(INPH, "YCOR:DOG:357:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "YCOR:DOG:357:STDZITOLR")
  field(INPC, "YCOR:DOG:357:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:215:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "YCOR:DOG:357:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:215:RESET PP
#
record(bo, "YCOR:DOG:357:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:215:RESET PP")
}

record(bo, "YCOR:DOG:357:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:215:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "YCOR:DOG:357:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "YCOR:DOG:357:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:215:IRAMPRATE PP")
  field(FLNK, "YCOR:DOG:357:STDZDLY")
}


record(ao, "YCOR:DOG:357:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:215:ISETPT PP")
  field(DOL, "YCOR:DOG:357:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "YCOR:DOG:357:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:215:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "YCOR:DOG:357:BMON")
}

record(ao, "YCOR:DOG:357:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:215:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "YCOR:DOG:357:IRIPLOK")
}

record(sub, "YCOR:DOG:357:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "YCOR:DOG:357:IRIPL.VAL")
  field(INPB, "YCOR:DOG:357:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:DOG:357:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "YCOR:DOG:357:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "YCOR:DOG:357:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:215:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "YCOR:DOG:357:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:215:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "YCOR:DOG:357:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:DOG:357:IACTPREVOK")
  field(LNK2, "YCOR:DOG:357:IDIFF")
  field(LNK3, "YCOR:DOG:357:IADIFF")
  field(LNK4, "YCOR:DOG:357:IRATIO")
  field(LNK5, "YCOR:DOG:357:IDIRECT")
  field(LNK6, "YCOR:DOG:357:IACTPOL_CHECK")
}

record(calc, "YCOR:DOG:357:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:DOG:357:IDES")
  field(INPB, "YCOR:DOG:357:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1")
  field(LOPR, "-1")
}

record(calc, "YCOR:DOG:357:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "YCOR:DOG:357:IDIFF")
  field(PREC, "9")
}

record(calc, "YCOR:DOG:357:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:DOG:357:IDIFF")
  field(INPB, "YCOR:DOG:357:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "YCOR:DOG:357:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "YCOR:DOG:357:IMIN")
  field(INPB,   "YCOR:DOG:357:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "YCOR:DOG:357:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "YCOR:DOG:357:IACT")
  field(INPB, "YCOR:DOG:357:IDES")
  field(INPC, "YCOR:DOG:357:ISETPT")
  field(INPD, "YCOR:DOG:357:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "YCOR:DOG:357:IADJUST PP")
}

record(bo, "YCOR:DOG:357:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "YCOR:DOG:357:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "YCOR:DOG:357:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "YCOR:DOG:357:IACT")
  field(FLNK, "YCOR:DOG:357:IACTPOL")
}
record(bo, "YCOR:DOG:357:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:DOG:357:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"YCOR:DOG:357:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:DOG:357:IDELTAS and the\n  YCOR:DOG:357:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"YCOR:DOG:357:IACT: \n  Get copy of YCOR:DOG:357:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"YCOR:DOG:357:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"YCOR:DOG:357:IDES:\n  Contains raw value calculated by \nYCOR:DOG:357:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nYCOR:DOG:357:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"YCOR:DOG:357:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  YCOR:DOG:357:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               YCOR:DOG:357:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"YCOR:DOG:357:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by YCOR:DOG:357:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, YCOR:DOG:357:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  YCOR:DOG:357:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "YCOR:DOG:357:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:357:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:DOG:357:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:DOG:357:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:DOG:357:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "YCOR:DOG:357:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "YCOR:DOG:357:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "YCOR:DOG:357:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "YCOR:DOG:357:TRIMTYPE.RVAL")
  field(INPB,   "YCOR:DOG:357:CONFIG.RVAL")
  field(OUT,    "YCOR:DOG:357:TRIMMAXNUM PP")
}
record(longout, "YCOR:DOG:357:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "YCOR:DOG:357:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "YCOR:DOG:357:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "YCOR:DOG:357:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "YCOR:DOG:357:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "YCOR:DOG:357:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "YCOR:DOG:357:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "YCOR:DOG:357:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "YCOR:DOG:357:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "YCOR:DOG:357:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "YCOR:DOG:357:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "YCOR:DOG:357:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "YCOR:DOG:357:IMOVE")
 field(INPB, "YCOR:DOG:357:IACT")
 field(INPC, "YCOR:DOG:357:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "YCOR:DOG:357:TRIMDLYPCT")
 field(INPF, "YCOR:DOG:357:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "YCOR:DOG:357:RAMPTIME_LEFT PP")
}

record(longout, "YCOR:DOG:357:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "YCOR:DOG:357:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "YCOR:DOG:357:RAMPDONE_CALC")
}

record(calc, "YCOR:DOG:357:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "YCOR:DOG:357:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "YCOR:DOG:357:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "YCOR:DOG:357:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:DOG:357:RAMPTIME_LEFT")
 field(OUT,  "YCOR:DOG:357:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "YCOR:DOG:357:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "YCOR:DOG:357:RAMPTIME_LEFT NMS")
 field(OUT,  "YCOR:DOG:357:RAMPDONE PP")
}

record(bo, "YCOR:DOG:357:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "YCOR:DOG:357:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "YCOR:DOG:357:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "YCOR:DOG:357:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:357:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "YCOR:DOG:357:DEBUG.PROC PP")
  field(LNK2, "YCOR:DOG:357:STDZCYCLENUM.PROC PP")
  field(LNK3, "YCOR:DOG:357:STDZDISABLE.PROC PP")
  field(LNK4, "YCOR:DOG:357:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "YCOR:DOG:357:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "YCOR:DOG:357:STDZIMIN NPP NMS")
  field(INPB, "YCOR:DOG:357:STDZIMAX NPP NMS")
  field(INPC, "YCOR:DOG:357:STDZIFINAL NPP NMS")
  field(INPD, "YCOR:DOG:357:STDZCYCLENUM NPP NMS")
  field(INPE, "YCOR:DOG:357:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "YCOR:DOG:357:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "YCOR:DOG:357:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "YCOR:DOG:357:STDZWF PP")
  field(OUTB, "YCOR:DOG:357:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "YCOR:DOG:357:STDZWF")
}

record(mbbo, "YCOR:DOG:357:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "YCOR:DOG:357:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "YCOR:DOG:357:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "YCOR:DOG:357:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "YCOR:DOG:357:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "YCOR:DOG:357:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "YCOR:DOG:357:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:DOG:357:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "YCOR:DOG:357:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "YCOR:DOG:357:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:357:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "YCOR:DOG:357:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "YCOR:DOG:357:STDZIMIN")
}

record(ao, "YCOR:DOG:357:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL,  "-1")
  field(FLNK, "YCOR:DOG:357:STDZIMAX")
}

record(ao, "YCOR:DOG:357:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL,  "1")
  field(FLNK, "YCOR:DOG:357:STDZIFINAL")
}

record(ao, "YCOR:DOG:357:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL,  "-1")
  field(FLNK, "YCOR:DOG:357:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "YCOR:DOG:357:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "YCOR:DOG:357:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "YCOR:DOG:357:STDZIMIN CP NMS")
  field(INPB, "YCOR:DOG:357:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "YCOR:DOG:357:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "YCOR:DOG:357:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "YCOR:DOG:357:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "YCOR:DOG:357:STDZIMIN CP NMS")
  field(INPB, "YCOR:DOG:357:STDZIMAX CP NMS")
  field(INPC, "YCOR:DOG:357:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:357:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "YCOR:DOG:357:TRIMDLYPCT CP MS")
  field(INPB, "YCOR:DOG:357:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "YCOR:DOG:357:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "YCOR:DOG:357:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:357:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "YCOR:DOG:357:IDES.HOPR")
  field(INPB, "YCOR:DOG:357:STDZMINIPCT CPP NMS")
  field(INPC, "YCOR:DOG:357:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "YCOR:DOG:357:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "YCOR:DOG:357:IDES.HOPR")
  field(INPB, "YCOR:DOG:357:IDES.LOPR")
  field(INPC, "YCOR:DOG:357:STDZDIRECT.RVAL")
  field(INPD, "YCOR:DOG:357:STDZMINIDELTA")
  field(INPE, "YCOR:DOG:357:IDES")
  field(PREC, "5")
  field(FLNK, "YCOR:DOG:357:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "YCOR:DOG:357:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "YCOR:DOG:357:IDES.HOPR")
  field(INPB, "YCOR:DOG:357:IDES.LOPR")
  field(INPC, "YCOR:DOG:357:STDZDIRECT.RVAL")
  field(INPD, "YCOR:DOG:357:STDZMINIDELTA")
  field(INPE, "YCOR:DOG:357:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "YCOR:DOG:357:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "YCOR:DOG:357:IADJUST.RVAL")
  field(INPB, "YCOR:DOG:357:STDZDIRECT.RVAL")
  field(INPC, "YCOR:DOG:357:STDZOK.RVAL")
  field(INPD, "YCOR:DOG:357:STDZDISABLE.RVAL")
  field(INPE, "YCOR:DOG:357:STATE.RVAL CPP NMS")
  field(INPF, "YCOR:DOG:357:ICTRL.RVAL")
  field(INPG, "YCOR:DOG:357:STATE.SEVR")
  field(INPH, "YCOR:DOG:357:BDELTAS.M")
  field(INPI, "YCOR:DOG:357:IACT.SEVR")
  field(OUT,  "YCOR:DOG:357:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "YCOR:DOG:357:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "YCOR:DOG:357:STDZLOSTTOD.PROC")
  field(LNK2, "YCOR:DOG:357:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "YCOR:DOG:357:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:357:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:DOG:357:IACT CP")
  field(INPB, "YCOR:DOG:357:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "YCOR:DOG:357:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "YCOR:DOG:357:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:357:CHECKPWRDIP_ENABLE")
  field(INPA, "YCOR:DOG:357:STDZIACTMAX")
  field(INPB, "YCOR:DOG:357:IACT")
  field(INPC, "YCOR:DOG:357:IDELTAS.I")
  field(OUT,  "YCOR:DOG:357:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "YCOR:DOG:357:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "YCOR:DOG:357:STDZOK.RVAL CP")
  field(INPB, "YCOR:DOG:357:STDZDISABLE.RVAL CP")
  field(INPC, "YCOR:DOG:357:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "YCOR:DOG:357:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "YCOR:DOG:357:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "YCOR:DOG:357:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "YCOR:DOG:357:CALBOK")
  field(INPB, "YCOR:DOG:357:CALBDISABLE")
  field(INPC, "YCOR:DOG:357:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "YCOR:DOG:357:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "YCOR:DOG:357:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "YCOR:DOG:357:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "YCOR:DOG:357:CALBSLOPE")
  field(DOL3, "YCOR:DOG:357:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "YCOR:DOG:357:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:357:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "YCOR:DOG:357:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "YCOR:DOG:357:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "YCOR:DOG:357:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "YCOR:DOG:357:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "YCOR:DOG:357:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:357:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "YCOR:DOG:357:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:357:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "YCOR:DOG:357:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "YCOR:DOG:357:IACT")
  field(INPD, "YCOR:DOG:357:DACSLOPE")
  field(INPE, "YCOR:DOG:357:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "YCOR:DOG:357:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "YCOR:DOG:357:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "1")
  field(HOPR, "1")
  field(DRVL, "-1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "YCOR:DOG:357:CALBIMAX")
}

record(ao, "YCOR:DOG:357:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "1")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVL, "-1")
  field(EGU,  "A")
  field(VAL,  "1")
  field(FLNK, "YCOR:DOG:357:CALBSTEPNUM")
}

record(ao, "YCOR:DOG:357:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL, "0")
}

record(longout, "YCOR:DOG:357:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:DOG:357:CALBIDELTA")
}

record(calc, "YCOR:DOG:357:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "YCOR:DOG:357:CALBIMAX")
  field(INPB, "YCOR:DOG:357:CALBIMIN")
  field(INPC, "YCOR:DOG:357:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "YCOR:DOG:357:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:215:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:215:IACT.HOPR")
  field(INPC, "YCOR:DOG:357:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "YCOR:DOG:357:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:DOG:357:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:357:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:357:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:357:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "YCOR:DOG:357:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:357:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:357:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:357:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "YCOR:DOG:357:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:357:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:357:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "YCOR:DOG:357:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "YCOR:DOG:357:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:357:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "YCOR:DOG:357:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "YCOR:DOG:357:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "YCOR:DOG:357:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "YCOR:DOG:357:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "YCOR:DOG:357:CALBSTEPNUM")
  field(INPB, "YCOR:DOG:357:CALBIACTWF")
  field(INPC, "YCOR:DOG:357:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "YCOR:DOG:357:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "YCOR:DOG:357:STDZITOL")

  field(INPH, "YCOR:DOG:357:DACSLOPE")
  field(INPI, "YCOR:DOG:357:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "YCOR:DOG:357:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "YCOR:DOG:357:CALBSTEPNUM")
  field(INPB, "YCOR:DOG:357:CALBIACTWF")
  field(INPC, "YCOR:DOG:357:DACWF")
  field(INPF, "YCOR:DOG:357:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe YCOR:DOG:357CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "YCOR:DOG:357:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "YCOR:DOG:357:DEGAUSIMIN.PROC PP")
  field(OUTB, "YCOR:DOG:357:DEGAUSIMAX.PROC PP")
  field(OUTC, "YCOR:DOG:357:DEGAUSTYPE.PROC PP")
  field(OUTD, "YCOR:DOG:357:DEGAUSSTEP.PROC PP")
  field(OUTE, "YCOR:DOG:357:MADNAME.PROC PP")
  field(OUTF, "YCOR:DOG:357:PSTYPE.PROC PP")
  field(OUTG, "YCOR:DOG:357:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "YCOR:DOG:357:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:DOG:357:DEGAUSIMIN NPP NMS")
  field(INPB, "YCOR:DOG:357:DEGAUSIMAX NPP NMS")
  field(INPC, "YCOR:DOG:357:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "YCOR:DOG:357:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "YCOR:DOG:357:PSTYPE NPP NMS")
  field(INPG, "YCOR:DOG:357:DEBUG.RVAL NPP NMS")
  field(INPH, "YCOR:DOG:357:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "YCOR:DOG:357:DEGAUSWF PP")
  field(OUTB, "YCOR:DOG:357:DEGAUSMSG PP")
  field(OUTC, "YCOR:DOG:357:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "YCOR:DOG:357:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"YCOR:DOG:357:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "YCOR:DOG:357:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "YCOR:DOG:357:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "YCOR:DOG:357:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "YCOR:DOG:357:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "YCOR:DOG:357:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(VAL,  "-1")
}
record(ao, "YCOR:DOG:357:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(VAL,  "1")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"YCOR:DOG:357:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "YCOR:DOG:357:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"YCOR:DOG:357:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "YCOR:DOG:357:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "YCOR:DOG:357:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "YCOR:DOG:357:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "YCOR:DOG:357:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "YCOR:DOG:357:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:357:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "YCOR:DOG:357:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "YCOR:DOG:357:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "YCOR:DOG:357:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "YCOR:DOG:357:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "YCOR:DOG:357:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "YCOR:DOG:357:DEGAUS_IMAX")
  field(INPB, "YCOR:DOG:357:ISETPT")
  field(INPC, "YCOR:DOG:357:DEGAUSTYPE.RVAL")
  field(OUT,  "YCOR:DOG:357:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "YCOR:DOG:357:DEGAUS_IMAX_UPDATE")
}
record(seq, "YCOR:DOG:357:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "YCOR:DOG:357:ISETPT")
  field(LNK1, "YCOR:DOG:357:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "YCOR:DOG:357:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(VAL,  "1")
  field(FLNK, "YCOR:DOG:357:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "YCOR:DOG:357:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "YCOR:DOG:357:DEGAUS_IMAX")
  field(FLNK, "YCOR:DOG:357:DEGAUS_IMAXPOL")
}
record(bo, "YCOR:DOG:357:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "YCOR:DOG:357:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "YCOR:DOG:357:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "YCOR:DOG:357:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "YCOR:DOG:357:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "1")
  field(LOPR, "-1")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "YCOR:DOG:357:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "YCOR:DOG:357:IACT")
  field(INPB, "YCOR:DOG:357:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "YCOR:DOG:357:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "YCOR:DOG:357:IACTPOL")
}
record(bo, "YCOR:DOG:357:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"YCOR:DOG:357:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "YCOR:DOG:357:DEGAUSENABLE CP")
  field(INPB, "YCOR:DOG:357:DEGAUSOK")
  field(INPC, "YCOR:DOG:357:STATE CP")
  field(INPD, "YCOR:DOG:357:STATE.SEVR")
  field(OUT,  "YCOR:DOG:357:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "YCOR:DOG:357:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "YCOR:DOG:357:DEGAUS_STATE_CHECK")
  field(LNK1, "YCOR:DOG:357:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "YCOR:DOG:357:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "YCOR:DOG:357:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "YCOR:DOG:357:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "YCOR:DOG:357:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "YCOR:DOG:357:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:DOG:357:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "YCOR:DOG:357:STATMSG.FRSV")
  field(LNK4, "YCOR:DOG:357:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:DOG:357:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:357:DEGAUSOK.ZSV")
  field(LNK2, "YCOR:DOG:357:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "YCOR:DOG:357:STATMSG.FRSV")
  field(LNK4, "YCOR:DOG:357:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "YCOR:DOG:357:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "YCOR:DOG:357:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "YCOR:DOG:357:STATMSG.FRSV")
  field(LNK3, "YCOR:DOG:357:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "YCOR:DOG:357:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:357:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "YCOR:DOG:357:STATMSG.FRSV PP")
  field(LNK3, "YCOR:DOG:357:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "YCOR:DOG:357:FUNC") {
  field(DESC, "YCOR:DOG:357 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "YCOR:DOG:357:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:DOG:357:CTRL") {
  field(DESC, "YCOR:DOG:357 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "YCOR:DOG:357:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "YCOR:DOG:357:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "YCOR:DOG:357:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "YCOR:DOG:357:BUSY") {
  field(DESC, "YCOR:DOG:357 Ctrl Done")
  field(DOL, "YCOR:DOG:357:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:357:SELECT")
}

record(bo, "YCOR:DOG:357:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "YCOR:DOG:357:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "YCOR:DOG:357:CTRLSTATE") {
  field(DESC, "YCOR:DOG:357 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("YCOR:DOG:357:CTRL",20,20,0,0,"YCOR:DOG:357:CTRL")
#! Field("YCOR:DOG:357:CTRL.OUT",16777215,1,"YCOR:DOG:357:CTRL.OUT")
#! Link("YCOR:DOG:357:CTRL.OUT","YCOR:DOG:357:SELECTEN.A")
#! Field("YCOR:DOG:357:CTRL.VAL",16777215,1,"YCOR:DOG:357:CTRL.VAL")
#! Record("YCOR:DOG:357:SELECTEN",321,381,0,0,"YCOR:DOG:357:SELECTEN")
#! Field("YCOR:DOG:357:SELECTEN.A",16777215,0,"YCOR:DOG:357:SELECTEN.A")
#! Field("YCOR:DOG:357:SELECTEN.FLNK",16777215,1,"YCOR:DOG:357:SELECTEN.FLNK")
#! Link("YCOR:DOG:357:SELECTEN.FLNK","YCOR:DOG:357:BUSY")
#! Field("YCOR:DOG:357:SELECTEN.VAL",16777215,1,"YCOR:DOG:357:SELECTEN.VAL")
#! Record("YCOR:DOG:357:BUSY",623,274,0,0,"YCOR:DOG:357:BUSY")
#! Field("YCOR:DOG:357:BUSY.DOL",16777215,0,"YCOR:DOG:357:BUSY.DOL")
#! Link("YCOR:DOG:357:BUSY.DOL","YCOR:DOG:357:SELECTEN.VAL")
#! Field("YCOR:DOG:357:BUSY.FLNK",16777215,1,"YCOR:DOG:357:BUSY.FLNK")
#! Link("YCOR:DOG:357:BUSY.FLNK","YCOR:DOG:357:SELECT")
#! Record("YCOR:DOG:357:SELECT",669,508,0,1,"YCOR:DOG:357:SELECT")
#! Record("YCOR:DOG:357:FUNC",940,120,0,0,"YCOR:DOG:357:FUNC")
#! Field("YCOR:DOG:357:FUNC.OUT",16777215,0,"YCOR:DOG:357:FUNC.OUT")
#! Link("YCOR:DOG:357:FUNC.OUT","YCOR:DOG:357:CTRL.VAL")
#! Record("YCOR:DOG:357:ABORT",193,41,0,0,"YCOR:DOG:357:ABORT")
#! Record("YCOR:DOG:357:CTRLSTATE",369,34,0,0,"YCOR:DOG:357:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"YCOR:DOG:357:SELECT is used for Multi-device selection.\nIt is enabled when associated YCOR:DOG:357:CTRL is \"0\" (DONE).\nIt is disabled when associated YCOR:DOG:357:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"YCOR:DOG:357:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "YCOR:DOG:357:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "YCOR:DOG:357:BCTRL.SEVR")
  field(OUT,  "YCOR:DOG:357:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "YCOR:DOG:357:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:DOG:357:BACT")
  field(INPB, "YCOR:DOG:357:POLYCOEF")
  field(INPC, "YCOR:DOG:357:POLYCOEF.A")
  field(INPD, "YCOR:DOG:357:POLYCOEF.B")
  field(INPE, "YCOR:DOG:357:IACT MS")
  field(INPF, "YCOR:DOG:357:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(HIHI, "0.01049318")
  field(LOLO, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.01049318")
  field(LOW,  "-0.01049318")
  field(FLNK, "YCOR:DOG:357:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "YCOR:DOG:357:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "YCOR:DOG:357:BDES")
  field(INPB, "YCOR:DOG:357:TRIMBTOL")
  field(INPC, "YCOR:DOG:357:TRIMBTOLR")
  field(INPD, "YCOR:DOG:357:CHCKBTOL")
  field(INPE, "YCOR:DOG:357:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "YCOR:DOG:357:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "YCOR:DOG:357:MPSBTOL")
  field(INPQ, "YCOR:DOG:357:MPSBTOLR")
  field(FLNK, "YCOR:DOG:357:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "YCOR:DOG:357:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "YCOR:DOG:357:BDES")
  field(INPB, "YCOR:DOG:357:BDELTAS.I")
  field(INPG, "YCOR:DOG:357:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "YCOR:DOG:357:BCON.HIGH")
  field(OUTB, "YCOR:DOG:357:BCON.LOW")
  field(OUTC, "YCOR:DOG:357:BCON.HIHI")
  field(OUTD, "YCOR:DOG:357:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:357:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "YCOR:DOG:357:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "YCOR:DOG:357:BDIFF")
  field(LNK2, "YCOR:DOG:357:BADIFF")
  field(LNK3, "YCOR:DOG:357:BRATIO")
  field(LNK4, "YCOR:DOG:357:MPSLIMITS")
  field(LNK5, "YCOR:DOG:357:I2BSTATUS")
  field(LNK6, "YCOR:DOG:357:IACTFO.PROC")
}

record(calc, "YCOR:DOG:357:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "YCOR:DOG:357:BDES")
  field(INPB, "YCOR:DOG:357:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "YCOR:DOG:357:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "YCOR:DOG:357:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "YCOR:DOG:357:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "YCOR:DOG:357:BDIFF")
  field(INPB, "YCOR:DOG:357:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "YCOR:DOG:357:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "YCOR:DOG:357:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "YCOR:DOG:357:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "YCOR:DOG:357:BMON")
  field(INPB, "YCOR:DOG:357:POLYCOEF")
  field(INPC, "YCOR:DOG:357:POLYCOEF.A")
  field(INPD, "YCOR:DOG:357:POLYCOEF.B")
  field(INPE, "YCOR:DOG:357:IMON MS")
  field(INPF, "YCOR:DOG:357:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(HIHI, "0.01049318")
  field(LOLO, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.01049318")
  field(LOW,  "-0.01049318")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:215:BDES CP
record(ao,  "YCOR:DOG:357:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.01049318")
   field(DRVL, "-0.01049318")
   field(HOPR, "0.01049318")
   field(LOPR, "-0.01049318")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "YCOR:DOG:357:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "YCOR:DOG:357:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:357:POLYCOEF")
  field(INPC, "YCOR:DOG:357:POLYCOEF.A")
  field(INPD, "YCOR:DOG:357:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(MDEL, "-1")
  field(INPE, "YCOR:DOG:357:BDES.DRVH")
  field(INPF, "YCOR:DOG:357:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:357:IDES")
}
record(sub, "YCOR:DOG:357:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:357:POLYCOEF")
  field(INPC, "YCOR:DOG:357:POLYCOEF.A")
  field(INPD, "YCOR:DOG:357:POLYCOEF.B")
  field(INPE, "YCOR:DOG:357:BDES.DRVH")
  field(INPF, "YCOR:DOG:357:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "YCOR:DOG:357:INOM")
}

record(sub, "YCOR:DOG:357:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:357:BDES.VAL")
  field(INPB, "YCOR:DOG:357:BDES.DRVH")
  field(INPC, "YCOR:DOG:357:BDES.DRVL")
  field(INPD, "YCOR:DOG:357:BDELTAS.I")
  field(INPE, "YCOR:DOG:357:BDELTAS.J")
  field(INPG, "YCOR:DOG:357:STATE")
  field(INPH, "YCOR:DOG:357:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "YCOR:DOG:357:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "YCOR:DOG:357:BDES.VAL")
  field(INPB, "YCOR:DOG:357:BDES.DRVH")
  field(INPC, "YCOR:DOG:357:BDES.DRVL")
  field(INPD, "YCOR:DOG:357:BDELTAS.K")
  field(INPE, "YCOR:DOG:357:BDELTAS.L")
  field(INPG, "YCOR:DOG:357:STATE")
  field(INPH, "YCOR:DOG:357:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "YCOR:DOG:357:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "YCOR:DOG:357:BLIMITS")
  field(LNK1, "YCOR:DOG:357:BACTLIMITS.F PP")
  field(DOL2, "YCOR:DOG:357:BACTLIMITS.I")
  field(LNK2, "YCOR:DOG:357:BACT.HIGH")
  field(DOL3, "YCOR:DOG:357:BACTLIMITS.J")
  field(LNK3, "YCOR:DOG:357:BACT.LOW")
  field(DOL4, "YCOR:DOG:357:BACTLIMITS.K")
  field(LNK4, "YCOR:DOG:357:BACT.HIHI")
  field(DOL5, "YCOR:DOG:357:BACTLIMITS.L")
  field(LNK5, "YCOR:DOG:357:BACT.LOLO")
  field(DOL6, "YCOR:DOG:357:BLIMITS")
  field(LNK6, "YCOR:DOG:357:BMONLIMITS.F PP")
  field(DOL7, "YCOR:DOG:357:BMONLIMITS.I")
  field(LNK7, "YCOR:DOG:357:BMON.HIGH")
  field(DOL8, "YCOR:DOG:357:BMONLIMITS.J")
  field(LNK8, "YCOR:DOG:357:BMON.LOW")
  field(DOL9, "YCOR:DOG:357:BMONLIMITS.K")
  field(LNK9, "YCOR:DOG:357:BMON.HIHI")
  field(DOLA, "YCOR:DOG:357:BMONLIMITS.L")
  field(LNKA, "YCOR:DOG:357:BMON.LOLO")
  field(FLNK, "YCOR:DOG:357:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "YCOR:DOG:357:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "YCOR:DOG:357:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "YCOR:DOG:357:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "YCOR:DOG:357:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "YCOR:DOG:357:BCTRL.VAL")
  field(LNK2, "YCOR:DOG:357:BDES PP")

  field(DOL3, "1")
  field(LNK3, "YCOR:DOG:357:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "YCOR:DOG:357:CHECKSTDZLOST.PROC PP")

  field(DOL5, "YCOR:DOG:357:BCTRL.VAL")
  field(LNK5, "YCOR:DOG:357:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "YCOR:DOG:357:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "YCOR:DOG:357:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:357:POLYCOEF")
  field(INPC, "YCOR:DOG:357:POLYCOEF.A")
  field(INPD, "YCOR:DOG:357:POLYCOEF.B")
  field(INPE, "YCOR:DOG:357:BDES.DRVH")
  field(INPF, "YCOR:DOG:357:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:357:ISETPT")
}

record(ao, "YCOR:DOG:357:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "YCOR:DOG:357:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "YCL4P")
}

record(ai, "YCOR:DOG:357:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "818.021175")
}

record(ao, "YCOR:DOG:357:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU, "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.01049318")
  field(FLNK, "YCOR:DOG:357:BSTEP")
}

record(ao, "YCOR:DOG:357:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU, "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(FLNK, "YCOR:DOG:357:BSTEP")
}

record(ao, "YCOR:DOG:357:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by YCOR:DOG:357:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "YCOR:DOG:357:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "YCOR:DOG:357:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "YCOR:DOG:357:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "YCOR:DOG:357:POLYCOEF")
  field(INPC, "YCOR:DOG:357:POLYCOEF.A")
  field(INPD, "YCOR:DOG:357:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(MDEL, "-1")
  field(INPE, "YCOR:DOG:357:BCON.DRVH")
  field(INPF, "YCOR:DOG:357:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "YCOR:DOG:357:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "YCOR:DOG:357:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "YCOR:DOG:357:BMAX")
  field(INPB, "YCOR:DOG:357:BMIN")
  field(INPC, "YCOR:DOG:357:BMIN.SEVR")
  field(INPD, "YCOR:DOG:357:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"YCOR:DOG:357:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "YCOR:DOG:357:ONLINE CP")
  field(OUT,  "YCOR:DOG:357:BCTRLDISABLEFOUT PP")
}

record(fanout, "YCOR:DOG:357:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "YCOR:DOG:357:BCTRLDISABLECALC")
  field(LNK1, "YCOR:DOG:357:BCTRLDISABLE")
  field(LNK2, "YCOR:DOG:357:BCTRLENABLE")
}

record(stringout, "YCOR:DOG:357:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:DOG:357:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "YCOR:DOG:357:BCTRLDISV_UPDATE")
}

record(stringout, "YCOR:DOG:357:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "YCOR:DOG:357:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "YCOR:DOG:357:BCTRLDISV_UPDATE")
}

record(calcout, "YCOR:DOG:357:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "YCOR:DOG:357:ONLINE")
  field(OUT,  "YCOR:DOG:357:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"YCOR:DOG:357:BACT and MON\n  are processed via links from \n  YCOR:DOG:357:IACT (device raw value readback 1)\n  and\n  YCOR:DOG:357:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from YCOR:DOG:357:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = YCOR:DOG:357:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"YCOR:DOG:357:BDES\n  is processed when set by CA users or \n  YCOR:DOG:357:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"YCOR:DOG:357:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  YCOR:DOG:357:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (YCOR:DOG:357:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"YCOR:DOG:357:B*LIMITS and YCOR:DOG:357:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from YCOR:DOG:357:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"YCOR:DOG:357:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"YCOR:DOG:357:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "YCOR:DOG:357:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "YCOR:DOG:357:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "YCOR:DOG:357:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "YCOR:DOG:357:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:357:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:357:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:357:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "YCOR:DOG:357:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "YCOR:DOG:357:MPSLIMITS.E PP")
}

record(aSub, "YCOR:DOG:357:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "YCOR:DOG:357:MPS.RVAL")
  field(INPB, "YCOR:DOG:357:BADIFF")
  field(INPC, "YCOR:DOG:357:BDELTAS.N")
  field(INPD, "YCOR:DOG:357:BACT")
  field(INPE, "YCOR:DOG:357:MPSBITMASK.RVAL")
  field(INPF, "YCOR:DOG:357:MPSBLLIM")
  field(INPG, "YCOR:DOG:357:MPSBMIN")
  field(INPH, "YCOR:DOG:357:MPSBMAX")
  field(INPI, "YCOR:DOG:357:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "YCOR:DOG:357:INTOL.RVAL PP")
  field(OUTB, "YCOR:DOG:357:INTOL_BMIN.RVAL PP")
  field(OUTC, "YCOR:DOG:357:INTOL_BRANGE.RVAL PP")
  field(OUTD, "YCOR:DOG:357:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "YCOR:DOG:357:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:357:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:357:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:357:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:357:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:357:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "YCOR:DOG:357:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "YCOR:DOG:357:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "YCOR:DOG:357:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "YCOR:DOG:357:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:DOG:357:CHCKBTOL")
  field(INPB, "YCOR:DOG:357:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "YCOR:DOG:357:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "YCOR:DOG:357:CHCKBTOL")
  field(FLNK, "YCOR:DOG:357:CHCKITOL")
}

record(calc, "YCOR:DOG:357:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "YCOR:DOG:357:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "YCOR:DOG:357:BDES.HOPR")
  field(INPB, "YCOR:DOG:357:STABILITY")
  field(INPC, "YCOR:DOG:357:BDES.LOPR")
}

record(longout, "YCOR:DOG:357:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "YCOR:DOG:357:CHCKBTOL")
}

record(calc, "YCOR:DOG:357:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "YCOR:DOG:357:POLYCOEF.B")
  field(INPB, "YCOR:DOG:357:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "YCOR:DOG:357:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "YCOR:DOG:357:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "YCOR:DOG:357:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "YCOR:DOG:357:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "YCOR:DOG:357:PAUGO")  
}

record(fanout, "YCOR:DOG:357:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "YCOR:DOG:357:PAUSTOP")
  field(LNK2, "YCOR:DOG:357:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "YCOR:DOG:357:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "YCOR:DOG:357:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:215:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:215:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "YCOR:DOG:357:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "YCOR:DOG:357:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:215:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:215:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "YCOR:DOG:357:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:215:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:DOG:357:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "YCOR:DOG:357:PSTYPE.RVAL")
  field(INPC, "YCOR:DOG:357:TURNEDOFF.RVAL")
  field(INPD, "YCOR:DOG:357:CONFIG.RVAL")
  field(INPE, "YCOR:DOG:357:PSCATEGORY.RVAL")
  field(INPF, "YCOR:DOG:357:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "YCOR:DOG:357:AUTOCTRL.RVAL")
  field(INPJ, "YCOR:DOG:357:OUTOFSERVICE.RVAL")
  field(INPL, "YCOR:DOG:357:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "YCOR:DOG:357:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "YCOR:DOG:357:PAU")
  field(INPP, "YCOR:DOG:357:CALBDISABLE.RVAL")
  field(INPQ, "YCOR:DOG:357:PTRBDISABLE.RVAL")
  field(INPR, "YCOR:DOG:357:TRIMDISABLE.RVAL")
  field(INPS, "YCOR:DOG:357:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "YCOR:DOG:357:FBCK")
  field(INPU, "YCOR:DOG:357:TRIMTYPE.RVAL")
  field(INPV, "YCOR:DOG:357:STDZDIRECT.RVAL")
  field(INPW, "YCOR:DOG:357:DEGAUSENABLE.RVAL")
  field(FLNK, "YCOR:DOG:357:HSTA")
}

record(longin, "YCOR:DOG:357:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "YCOR:DOG:357:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "YCOR:DOG:357:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "YCOR:DOG:357:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "YCOR:DOG:357:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:357:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:357:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "YCOR:DOG:357:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by YCOR:DOG:357:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses YCOR:DOG:357:FBCK.
# This PV should be replaced by YCOR:DOG:357:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "YCOR:DOG:357:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "YCOR:DOG:357:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:DOG:357:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:357:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"YCOR:DOG:357:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "YCOR:DOG:357:OUTOFSERVICE NPP NMS")
  field(OUT,  "YCOR:DOG:357:ONLINE PP")
}
record(bo, "YCOR:DOG:357:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "YCOR:DOG:357:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "YCOR:DOG:357:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "YCOR:DOG:357:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "YCOR:DOG:357:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "YCOR:DOG:357:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "YCOR:DOG:357:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "YCOR:DOG:357:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "YCOR:DOG:357:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:357:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:357:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "YCOR:DOG:357:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "YCOR:DOG:357:TRIMTYPE")
}

record(stringout, "YCOR:DOG:357:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "YCOR:DOG:357:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "YCOR:DOG:357:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "YCOR:DOG:357:STATE.RVAL")
  field(INPB, "YCOR:DOG:357:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:DOG:357:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:DOG:357:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "YCOR:DOG:357:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "YCOR:DOG:357:STATE.RVAL")
  field(INPB, "YCOR:DOG:357:INTLKSUMY.RVAL")
  field(OUT,  "YCOR:DOG:357:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "YCOR:DOG:357:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "YCOR:DOG:357:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "YCOR:DOG:357:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "YCOR:DOG:357:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "YCOR:DOG:357:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "YCOR:DOG:357:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"YCOR:DOG:357:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("YCOR:DOG:357:TURNEDOFF",3140,1907,0,1,"YCOR:DOG:357:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "YCOR:DOG:357:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "YCOR:DOG:357:BACT.STAT")
  field(INPB, "YCOR:DOG:357:BDES.STAT")
  field(INPC, "YCOR:DOG:357:IRIPL.STAT")
  field(INPD, "MCOR:EXT:215:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:215:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "YCOR:DOG:357:BACT.SEVR")
  field(INPH, "YCOR:DOG:357:BDES.SEVR")
  field(INPI, "YCOR:DOG:357:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:215:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:215:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "YCOR:DOG:357:STATE.RVAL")
  field(INPN, "YCOR:DOG:357:STDZOK")
  field(INPO, "YCOR:DOG:357:CALBOK")
  field(INPP, "YCOR:DOG:357:OUTOFSERVICE.RVAL")
  field(INPQ, "YCOR:DOG:357:CONFIG.RVAL")
  field(INPR, "YCOR:DOG:357:HSTA")
  field(INPS, "YCOR:DOG:357:CTRL.RVAL")
  field(INPT, "YCOR:DOG:357:DEGAUSOK") 
  field(INPV, "YCOR:DOG:357:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:357:STAT")
}

record(longout, "YCOR:DOG:357:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "YCOR:DOG:357:STATCTRLSUB")
  field(DOL, "YCOR:DOG:357:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "YCOR:DOG:357:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "YCOR:DOG:357:STAT")
  field(INPB, "YCOR:DOG:357:HSTA")
  field(INPD, "YCOR:DOG:357:ONOFFCTRL.RVAL")
  field(FLNK, "YCOR:DOG:357:STATMSG")
}

record(mbbo, "YCOR:DOG:357:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "YCOR:DOG:357:UNAVAILGO")
  field(DOL, "YCOR:DOG:357:STATCTRLSUB.W")
}

record(seq, "YCOR:DOG:357:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "YCOR:DOG:357:STATSUB.U")
  field(LNK1, "YCOR:DOG:357:UNAVAIL PP")
}

record(stringout, "YCOR:DOG:357:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"YCOR:DOG:357:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - YCOR:DOG:357:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - YCOR:DOG:357:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"YCOR:DOG:357STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - YCOR:DOG:357:STATUS\nC - YCOR:DOG:357:ON\nD - YCOR:DOG:357:STDZOK\nE - YCOR:DOG:357:CALBOK\nF - YCOR:DOG:357:BACTDRIFT (future)\nG -\nH- YCOR:DOG:357:DACSTATUS\nI -YCOR:DOG:357:ADCSTATUS\nJ - YCOR:DOG:357:BACTSTATUS\nK - YCOR:DOG:357:BDESSTATUS\nL - YCOR:DOG:357:RIPLSTATUS\n\nOutput:\nP - YCOR:DOG:357:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "YCOR:DOG:357:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "YCOR:DOG:357:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "YCOR:DOG:357:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "YCOR:DOG:357:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Note: for slave with trim coils
# set the macro ACT to the following:
#  ACT=<dev>:IACTCALC
record(ai, "XCOR:DOG:408:IACT") {
  field(DESC, "Current")
  field(INP,  "MCOR:EXT:216:IACT CP MS")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:DOG:408:BACT")
  info(autosaveFields,"HYST")
}

record(bi, "XCOR:DOG:408:STATE") {
  field(DESC, "PS On/Off Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:216:STATE NPP MS")
  field(ZSV,   "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}

record(ao, "XCOR:DOG:408:IDES") {
  field(DESC, "Desired Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(MDEL, "-1")
  field(HIHI, "1")
  field(LOLO, "-1")
  field(HSV,  "MINOR")
  field(LSV,   "MINOR")
  field(FLNK, "XCOR:DOG:408:BDELTAS")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(DOL,  "XCOR:DOG:408:B2IDES.K")
  field(OMSL, "closed_loop")
# Note: set LNK to blank for Large PS (LGPS)
# where the user doesn't have any analog control
# as the ps voltae/current is always set to imax
# field(OUT, "XCOR:DOG:408:ICTRL PP")
}

# This record is processed by XCOR:DOG:408:ICON")
# Note: we are not setting alarms here.
record(ao, "XCOR:DOG:408:ICON") {
  field(DESC, "Config I")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(DOL,  "XCOR:DOG:408:B2ICON.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:408:INOM") {
  field(DESC, "Nominal Current")
  field(DOL, "XCOR:DOG:408:BNOM.K")
  field(OMSL, "closed_loop")
  field(PREC, "3")
  field(EGU, "A")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(HOPR, "1")
  field(LOPR, "-1")
}

record(ao, "XCOR:DOG:408:ICTRL") {
  field(DESC, "Set Current")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(MDEL, "-1")
  field(FLNK, "XCOR:DOG:408:ICTRLGO")
  field(OMSL, "supervisory")
  info(autosavefields,"VAL")
}

record(seq, "XCOR:DOG:408:ICTRLGO") {
  field(DESC, "Process Current Setpoint")
  field(PREC, "3")
# Set  ISETPT to supervisory
  field(DOL1, "0")
  field(LNK1, "XCOR:DOG:408:ISETPT.OMSL")

  field(DOL2, "XCOR:DOG:408:ICTRL")
  field(LNK2, "XCOR:DOG:408:ISETPT PP")

# Set ISETPT to closed loop - get data from BCTRLSUB.K
  field(DOL3, "1")
  field(LNK3, "XCOR:DOG:408:ISETPT.OMSL")
}

record(ao, "XCOR:DOG:408:IMAX") {
  field(DESC, "Max I")
  field(DTYP, "Soft Channel")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(PINI, "YES")
  field(VAL,  "1")
  field(FLNK, "XCOR:DOG:408:IMIN")
}

record(ao, "XCOR:DOG:408:IMIN") {
  field(DESC, "Min I")
  field(DTYP, "Soft Channel")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(VAL,  "-1")
  field(FLNK, "XCOR:DOG:408:IRANGE")
}

record(sel, "XCOR:DOG:408:IACTPREVOK") {
  field(DESC, "Last Good Current")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(NVL,  "XCOR:DOG:408:BACT.SEVR")
  field(INPA, "XCOR:DOG:408:IACT NPP MS")
  field(INPB, "XCOR:DOG:408:IACTPREVOK NPP MS")
  field(INPC, "XCOR:DOG:408:IACTPREVOK NPP MS")
  field(INPD, "XCOR:DOG:408:IACTPREVOK NPP MS")
}

record(sub, "XCOR:DOG:408:IACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:408:IDES")
  field(INPB, "XCOR:DOG:408:ISETPT.DRVH")
  field(INPC, "XCOR:DOG:408:ISETPT.DRVL")
  field(INPD, "XCOR:DOG:408:IDELTAS.I")
  field(INPE, "XCOR:DOG:408:IDELTAS.J")
  field(INPG, "XCOR:DOG:408:STATE")
  field(INPH, "XCOR:DOG:408:HSTA")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:DOG:408:IMONLIMITS") {
  field(DESC, "Aux Current Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:408:IDES")
  field(INPB, "XCOR:DOG:408:ISETPT.DRVH")
  field(INPC, "XCOR:DOG:408:ISETPT.DRVL")
  field(INPD, "XCOR:DOG:408:IDELTAS.K")
  field(INPE, "XCOR:DOG:408:IDELTAS.L")
  field(INPG, "XCOR:DOG:408:STATE")
  field(INPH, "XCOR:DOG:408:HSTA")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:DOG:408:ILIMITS") {
  field(DESC, "Set ACT and MON Limits")
  field(PREC, "3")
  field(DOL1, "XCOR:DOG:408:BLIMITS")
  field(LNK1, "XCOR:DOG:408:IACTLIMITS.F PP")
  field(DOL2, "XCOR:DOG:408:IACTLIMITS.I")
  field(LNK2, "XCOR:DOG:408:IACT.HIGH")
  field(DOL3, "XCOR:DOG:408:IACTLIMITS.J")
  field(LNK3, "XCOR:DOG:408:IACT.LOW")
  field(DOL4, "XCOR:DOG:408:IACTLIMITS.K")
  field(LNK4, "XCOR:DOG:408:IACT.HIHI")
  field(DOL5, "XCOR:DOG:408:IACTLIMITS.L")
  field(LNK5, "XCOR:DOG:408:IACT.LOLO")
  field(DOL6, "XCOR:DOG:408:BLIMITS")
  field(LNK6, "XCOR:DOG:408:IMONLIMITS.F PP")
  field(DOL7, "XCOR:DOG:408:IMONLIMITS.I")
  field(LNK7, "XCOR:DOG:408:IMON.HIGH")
  field(DOL8, "XCOR:DOG:408:IMONLIMITS.J")
  field(LNK8, "XCOR:DOG:408:IMON.LOW")
  field(DOL9, "XCOR:DOG:408:IMONLIMITS.K")
  field(LNK9, "XCOR:DOG:408:IMON.HIHI")
  field(DOLA, "XCOR:DOG:408:IMONLIMITS.L")
  field(LNKA, "XCOR:DOG:408:IMON.LOLO")
}

# Outputs:
# -------
# Inputs B and C are use for calibration and standardization.
#  ATOL(1) is the loose tolerance on the desired current-ADC measured current
#  ATOL(2) is the fractional tolerance.
# A = Desired Value (not used)
# B = Caculated stdz tolerance as % of max current (slc ATOL(1))
# C = Minimum stdz tolerance (slc ATOL(2))
# I = ACT warning delta (slc TOLMX)
# J = ACT alarm   delta (slc CURR_TOL)
# K = MON warning delta
# L = MON alarm   delta
# VAL = standardize tolerance max(b,c)
#
record(sSub, "XCOR:DOG:408:IDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRawDeltas")
  field(INPD, "XCOR:DOG:408:TRIMBTOL")
  field(INPE, "XCOR:DOG:408:CHCKBTOL")
  field(INPF, "XCOR:DOG:408:BDELTAS.K")
  field(INPG, "XCOR:DOG:408:BDELTAS.L")
  field(INPH, "XCOR:DOG:408:B2IDES.L")
  field(EGU,  "A")
  field(HOPR, "1")
  field(PREC, "3")
  field(BRSV, "INVALID")
#
# Used to calcualte standardize tolerance
# which is returned in the VAL field.
#
  field(INPB, "XCOR:DOG:408:STDZITOLR")
  field(INPC, "XCOR:DOG:408:STDZITOL")
  field(FLNK, "")
}

# All ps controllers with on/off control will set the macro ONOF
# as follows:
#
#  ONOF = MCOR:EXT:216:STATESETPT PP
#
# Only slaves and the MCOR systems DO NOT have on/off controls
# of the ps. However, slaves get their ps On/Off status from the main.
# so the ONOF macro as defined above is unchanged. The MCOR system
# would set the ONOF macro to blank (default). However, the MCOR soft
# pvs for STATESETPT is a place holder that outpts nothing, so the ONOF
# macro can also be set to the ONOFF macro listed above.
#
# The hard and soft x-ray chicane magnets in the undulator and the
# xleap chicane in the ltu are powerd by MCOR. In addition, a chassis
# was built to provide individual MCOR channel on/off control. This
# chassis includes a contactor and beckhoff digial i/o. For these
# chicane magnets set the ONOF macro to the following:
#
#  ONOF = <dev>:CONTACTOR_SETPT PP
#
# Note: since the chicane magnets are powered by an MCOR
# the PS macro will be set to an MCOR channel PV, different
# than the contactor pvs for on/off control.
#
record(bo, "XCOR:DOG:408:STATESETPT") {
  field(DESC, "PS On/Off")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(OUT,  "")
  info(autosaveFields,"VAL RVAL")
}

# Only the MCOR and slaves set the macros RST to the default
# all other ps controllers with Fault Reset control should set
# the macro as follows:
#  RST = MCOR:EXT:216:RESET PP
#
record(bo, "XCOR:DOG:408:RESET") {
  field(DESC, "Interlock Latch Reset")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(HIGH, "1.0")
  field(OUT, "MCOR:EXT:216:RESET PP")
}

record(bo, "XCOR:DOG:408:RAMPSTATE") {
  field(DESC, "PS Ramp Status")
  field(DTYP, "Soft Channel")
  field(DOL,  "MCOR:EXT:216:RAMPSTATE NPP MS")
  field(OMSL, "closed_loop")
  field(ZNAM, "OFF")
  field(ONAM, "BUSY")
  field(OSV,  "MINOR")
  field(PINI, "NO")
}

# Ramp rate is defined in LCLS PRD 1.1-015
# Default: MCORs 1A/sec and EPSC 10A/sec
# Note: On boot this pv is processed
# by <dev>:TRIMRAMPRATE
record(ao, "XCOR:DOG:408:IRAMPRATE") {
  field(DESC, "Current Setpoint dI/dt limit")
  field(DTYP, "Soft Channel")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(HOPR, "20")
  field(LOPR, "0.1")
  field(EGU, "A/sec")
  field(PREC, "3")

# Set default to trim ramp rate on boot
# but need to change for degauss function.
  field(DOL,  "XCOR:DOG:408:TRIMRAMPRATE")
  field(OUT,  "MCOR:EXT:216:IRAMPRATE PP")
  field(FLNK, "XCOR:DOG:408:STDZDLY")
}


record(ao, "XCOR:DOG:408:ISETPT") {
  field(DESC, "Current Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:216:ISETPT PP")
  field(DOL, "XCOR:DOG:408:BCTRLSUB.K")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

# Note: for slave with trim coils
# set the macro MONFL to the following:
#  MONFL=<dev>:IMONCALC
record(ai, "XCOR:DOG:408:IMON") {
  field(DESC, "Aux Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(INP,  "MCOR:EXT:216:IMON CP MS")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(FLNK, "XCOR:DOG:408:BMON")
}

record(ao, "XCOR:DOG:408:IRIPL") {
  field(DESC, "Ripple Current")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DOL,  "MCOR:EXT:216:IRIPL NPP MS")
  field(OMSL, "closed_loop")
  field(EGU, "A")
  field(DRVH, "1.0")
  field(HOPR, "1.0")
  field(PREC, "3")
  field(FLNK, "XCOR:DOG:408:IRIPLOK")
}

record(sub, "XCOR:DOG:408:IRIPLOK") {
  field(DESC, "Ripple Current Status")
  field(INAM, "mgntInit")
  field(SNAM, "mgntRiplOK")
  field(INPA, "XCOR:DOG:408:IRIPL.VAL")
  field(INPB, "XCOR:DOG:408:IDELTAS.J")
  field(D,    "2.0")
}

# Resistance only available for
# Kickers and Magnets controlled by
# Ethernet PS Controllers. Resistance
# is not available for MCOR Bulks
# and magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:DOG:408:R") {
  field(DESC, "Resistance")
  field(EGU,  "Ohms")
  field(PREC, "4")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

# Gound current is only available for
# some Bulks, Kickers and Magnets controlled by
# Ethernet PS Controllers. Ground current
# is not available for magnets controlled by MCORs
# Note: The alarm status origniates from the input PV
record(ao, "XCOR:DOG:408:IGND") {
  field(DESC, "Ground Current")
  field(EGU,  "A")
  field(PREC, "6")
  field(PINI, "YES")
  field(DOL,  "")
  field(OMSL, "closed_loop")
}

record(bi, "XCOR:DOG:408:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(INP, "MCOR:EXT:216:INTLKSUMY NPP MS")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "NO")
}
record(mbbo, "XCOR:DOG:408:COOLING") {
  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "NO")
  field(DOL,  "MCOR:EXT:216:COOLING")
  field(OMSL, "closed_loop")
}

# The following PV is processed by <dev>:BACTFO
# which is processed by <dev>:BACT
record(fanout, "XCOR:DOG:408:IACTFO") {
  field(DESC, "IACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:DOG:408:IACTPREVOK")
  field(LNK2, "XCOR:DOG:408:IDIFF")
  field(LNK3, "XCOR:DOG:408:IADIFF")
  field(LNK4, "XCOR:DOG:408:IRATIO")
  field(LNK5, "XCOR:DOG:408:IDIRECT")
  field(LNK6, "XCOR:DOG:408:IACTPOL_CHECK")
}

record(calc, "XCOR:DOG:408:IDIFF") {
  field(DESC, "IDES-IACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:DOG:408:IDES")
  field(INPB, "XCOR:DOG:408:IACT")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1")
  field(LOPR, "-1")
}

record(calc, "XCOR:DOG:408:IADIFF") {
  field(DESC, "Absolute IDES-IACT")
  field(CALC, "A<0?ABS(A):A")
  field(INPA, "XCOR:DOG:408:IDIFF")
  field(PREC, "9")
}

record(calc, "XCOR:DOG:408:IRATIO") {
  field(DESC, "IDES-IACT/IMAX")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:DOG:408:IDIFF")
  field(INPB, "XCOR:DOG:408:IDES.DRVH")
  field(PREC, "9")
}

record(calcout, "XCOR:DOG:408:IRANGE") {
  field(DESC,   "Current Range")
  field(PINI,   "YES")
  field(CALC,   "ABS(A-B)")
  field(INPA,   "XCOR:DOG:408:IMIN")
  field(INPB,   "XCOR:DOG:408:IMAX")
  field(PREC,   "9")
}

# Process IDIRECT upon a new IDES, prior to setting ISETPT (or ICTRL)
# which in turn updates IACT
#
# Note: This pv is processed by BCTLLSUB
record(calcout, "XCOR:DOG:408:IDIRECT") {
  field(DESC, "Setting I 0=up,1=down")
#
# if CTRL.RVAL==2==Trim,then compare IDES w IACT; otherwise
# if CTRL.RVAL==7==Dac Zero, then compare 0 with IACT, otherwise compare IDES w ISETPT
#  field(CALC, "D==2?((B<A)?1:0):((B<C)?1:0)")
  field(CALC, "D=2?((B<A)?1:0):D=7?((0.<A)?1:0):((B<C)?1:0)")
  field(INPA, "XCOR:DOG:408:IACT")
  field(INPB, "XCOR:DOG:408:IDES")
  field(INPC, "XCOR:DOG:408:ISETPT")
  field(INPD, "XCOR:DOG:408:CTRL.RVAL")
  field(PREC, "1")
  field(OUT, "XCOR:DOG:408:IADJUST PP")
}

record(bo, "XCOR:DOG:408:IADJUST") {
  field(DESC, "Adjust I Direction")
  field(DTYP, "Soft Channel")
  field(DOL, "XCOR:DOG:408:IDIRECT")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(OMSL, "closed_loop")
}

# Polarity if the current from the
# requested ides, when the degaussok
# is true. This pv is set by the sequencer
# upon a trim request.
record(calcout, "XCOR:DOG:408:IACTPOL_CHECK") {
  field(DESC, "Determine I polarity")
  field(ASG,  "Internal")
  field(CALC, "A>=1?0:1")
  field(INPA, "XCOR:DOG:408:IACT")
  field(FLNK, "XCOR:DOG:408:IACTPOL")
}
record(bo, "XCOR:DOG:408:IACTPOL") {
  field(DESC, "Actual I Polarity")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:DOG:408:IACTPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}


#! TextBox(TB9,980,1478,1300,1618,0,"Dialog",12,1,16777215,"XCOR:DOG:408:I*LIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:DOG:408:IDELTAS and the\n  XCOR:DOG:408:IDES value.  \n  Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB8,361,1340,721,1420,0,"Dialog",12,1,16777215,"XCOR:DOG:408:IACT: \n  Get copy of XCOR:DOG:408:I.  \n",null)
#! TextBox(TB12,1280,3100,1760,3200,0,"Dialog",12,1,16777215,"XCOR:DOG:408:ICTRL and CTRLGO:\n  CTRL is set by users to update the hardware directly.  CTRL forces \n  processing of CTRLGO and, if enabled, CTRLGO copies CTRL to SETPT\n  and processes it.  When feedback is ON, CTRLGO is disabled and\n  CTRL is periodically processed.\n   ",null)
#! TextBox(TB6,52,1458,352,1858,0,"Dialog",12,1,16777215,"XCOR:DOG:408:IDES:\n  Contains raw value calculated by \nXCOR:DOG:408:B2IDES.  This record is periodically\nupdated when fast feedback is on. \n\nIt is assumed that the calibration and/or \nstandardization sequence will set the HIGH and \nLOW limits of IDES and in this case, \nIDES.HIGH is the same as IMAX in the \nSLC database.  If the sequence sets these, they \nwill need to be saved and restored across IOC \nreboots.  This record forces processing (via \nFLNK) of less time-critical records starting with \nXCOR:DOG:408:BDELTAS.\n",null)
#! TextBox(TB10,56,1940,316,2340,0,"Dialog",12,1,16777215,"XCOR:DOG:408:IDELTAS:\n  Calculate delta used for standardization.\n  Also, calculate alarm and warning deltas \n  for ACT and MON based on the deltas for\n  the physical units.  Multiply the physical\n  deltas by the slope to get an approximate\n  corresponding raw delta.\n  This record is processed after \n  XCOR:DOG:408:BDELTAS (via FLNK).\n  Input:\n  A = Desired Value\n  B = Absolute delta for standardization\n  C = Fraction of  desired value for\n         standardization delta\n  D to G = Deltas in physical units from \n               XCOR:DOG:408:BDELTAS\n  H = Approximate raw-to-physical slope\n  Output:\n  I to L = Deltas in raw units  \n  VAL = Standardization Delta\n\n",null)
#! TextBox(TB5,2120,3120,2560,3240,0,"Dialog",12,1,16777215,"XCOR:DOG:408:ISETPT:\n  Sets the hardware.  When fast feedback is set on, this record is\n  set to closed loop mode by XCOR:DOG:408:FBCKSTART sequence.  When \n  the loop is closed, this record takes input calculated by \n  BFBCK only.  When fast feedback is set off, XCOR:DOG:408:FBCKSTOP \n  will set it back to supervisory so that the value can be set by \n  XCOR:DOG:408:ICTRLGO. \n",null)
#! TextBox(TB4,457,1456,877,1956,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n\nSCAN = SCAN rate of ACT, MON, and RIPL\nDTYPI = Device Type of ACT, MON, and RIPL\nDTYPO = Device Type for ISETPT\nINPA = Input for I\nINPM = Input for MON\nOUT = Output for DES\nRAMPRATE = default PS ramprate di/dt\n",null)
#! TextBox(TB3,745,1385,1305,1425,0,"Dialog",18,1,16777215,"Controlled Devices - Raw Engineering Units Records",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(stringout, "XCOR:DOG:408:TRIMTOD") {
  field(DESC, "Last successful TRIM")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:408:TRIMTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:DOG:408:TRIMTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:DOG:408:TRIMTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:DOG:408:TRIMTRYCNT") {
  field(DESC, "No of tries to TRIM")
  field(PINI, "YES")
  field(VAL, "0")
}

# This pv is processed by <dev>:CONFIG
record(bo, "XCOR:DOG:408:TRIMTYPE") {
  field(DESC, "Trim algorithm")
  field(VAL, "0")
  field(ZNAM, "3_LINEAR")
  field(ONAM, "LINEAR")
  field(FLNK, "XCOR:DOG:408:TRIMMAXNUMCHK")
}
# If magnet is a slave then set max trim tries to 0
# Otherwise, if trim type is linear then set
# max trim tries to 1, else we have an mcor so set to the
# default of 10.
record(calcout, "XCOR:DOG:408:TRIMMAXNUMCHK") {
  field(CALC,   "B==1?0:A?1:10")
  field(INPA,   "XCOR:DOG:408:TRIMTYPE.RVAL")
  field(INPB,   "XCOR:DOG:408:CONFIG.RVAL")
  field(OUT,    "XCOR:DOG:408:TRIMMAXNUM PP")
}
record(longout, "XCOR:DOG:408:TRIMMAXNUM") {
  field(DESC, "Max TRIM tries")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
}

# Trim ramp rate saved in static restore file
# Note: on boot set the trim ramp rate
# the trim ramp rate is used for standardize
# but the degauss function sets it's own
# ramp rate.
# Note: if this is a string slave then
# set the ramp rate to the main.
record(ao, "XCOR:DOG:408:TRIMRAMPRATE") {
  field(DESC, "Trim Ramp rate ")
  field(PINI, "YES")
  field(ASG,  "IOC_MAINT")
  field(PREC, "3")
  field(EGU,  "A/sec")
  field(HOPR, "20.0")
  field(DRVH, "20.0")
  field(DRVL, "0.1")
  field(LOPR, "0.5")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "1")
  field(OUT,  "XCOR:DOG:408:IRAMPRATE PP")
}

# Trim settle time saved in static restore file
record(ao, "XCOR:DOG:408:TRIMSETL") {
  field(DESC, "TRIM Settle Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "60.0")
  field(DRVL, "0.0")
  field(HOPR, "60")
  field(LOPR, "0.0")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(VAL,  "10")

}

record(bo, "XCOR:DOG:408:TRIMOK") {
  field(DESC, "Trim Successful")
  field(PINI, "YES")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV,  "NO_ALARM")
  field(OSV,  "NO_ALARM")
  field(COSV, "NO_ALARM")
  info(autosaveFields, "VAL RVAL")
}

record(ao, "XCOR:DOG:408:TRIMDLYPCT") {
  field(DESC, "Trim Ramp Delay %")
  field(EGU, "sec")
  field(DRVH, "100.0")
  field(DRVL, "0.0")
  field(HOPR, "100")
  field(LOPR, "0.0")
  field(VAL,  "10.0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

# Note: only for mcor's that use ipac modules
record(ao, "XCOR:DOG:408:TRIMSTEPMIN") {
  field(DESC, "Min step in current")
  field(DTYP, "Soft Channel")
#  field(DOL, "")
  field(PREC, "7")
  field(EGUF, "10")
  field(EGUL, "0")
  field(EGU,  "A")
  field(HOPR, "10")
  field(LOPR, "0")
  field(VAL,  "0.0001")
}

record(bo, "XCOR:DOG:408:SOFTRAMP") {
  field(DESC, "Soft Ramp Enable")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
}

record(ao, "XCOR:DOG:408:SOFTSTEPTIME") {
  field(DESC, "Time between steps")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "10.0")
  field(DRVL, "0.1")
  field(EGU, "sec")
  field(HOPR, "10.0")
  field(LOPR, "0.1")
# Set the default delay  between softramp steps as 0.1 sec
# which is used for MCOR controlled magnets. Note that
# only MCOR currently use softramp.
  field(VAL, "0.1")
  field(PREC, "3")
}

# ---- Calcualted Ramp time PVs -----
#
# Populated by sequence
# This pv forces the ramp time to be calculated.
# Therefore, the ramp rate PV must be update first.
record(ao, "XCOR:DOG:408:IMOVE") {
 field(DESC, "Ramp distance")
 field(EGU,  "A")
 field(PINI, "YES")
 field(VAL,  "0")
 field(FLNK, "XCOR:DOG:408:RAMPTIME")
}

# ramp time based on current distance and ramp rate,
# Note: EPSC use cosine ramp,and a load facter C is used.
#
# D - multiplying factor (3.154/2 = 1.577) -- only for EPSC's.
# Otherwise set to 1.0
record(calcout, "XCOR:DOG:408:RAMPTIME") {
 field(DESC, "Calc Ramp Time (sec)")
 field(CALC, "C>0?MAX(G,ABS((A-B)/C)*D*(1+E/100)):0")
# field(CALC, "MAX(0,ABS(F))")
 field(INPA, "XCOR:DOG:408:IMOVE")
 field(INPB, "XCOR:DOG:408:IACT")
 field(INPC, "XCOR:DOG:408:IRAMPRATE")
 field(INPD, "1.0")
 field(INPE, "XCOR:DOG:408:TRIMDLYPCT")
 field(INPF, "XCOR:DOG:408:STDZRAMPDLY")
 field(INPG, "0.5")
 field(PREC, "5")
 field(EGU,  "sec")
 field(PINI, "YES")
 field(OUT, "XCOR:DOG:408:RAMPTIME_LEFT PP")
}

record(longout, "XCOR:DOG:408:RAMPTIME_LEFT") {
 field(DESC, "Ramp time left (sec)")
 field(EGU,  "sec")
 field(OUT,  "XCOR:DOG:408:RAMPTIME_MINUTES_LEFT.A PP")
 field(FLNK, "XCOR:DOG:408:RAMPDONE_CALC")
}

record(calc, "XCOR:DOG:408:RAMPTIME_MINUTES_LEFT") {
 field(DESC, "Ramp time left (min)")
 field(EGU,  "minutes")
 field(CALC, "A/60")
 field(INPA, "XCOR:DOG:408:RAMPTIME_LEFT")
 field(PREC, "2")
 field(FLNK, "XCOR:DOG:408:RAMPTIME_LEFT_CALC")
}

# Decrement the ramp time remaining by seconds
record(calcout, "XCOR:DOG:408:RAMPTIME_LEFT_CALC") {
 field(DESC, "Increment ramp time (sec)")
 field(SCAN, "1 second")
 field(CALC, "A>0?A-1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:DOG:408:RAMPTIME_LEFT")
 field(OUT,  "XCOR:DOG:408:RAMPTIME_LEFT PP MS")
 field(ASG,  "Internal")
}

record(calcout, "XCOR:DOG:408:RAMPDONE_CALC") {
 field(DESC, "Calc ramp time expired")
 field(ASG,  "Internal")
 field(CALC, "C?1:0")
 field(OOPT, "On Change")
 field(INPA, "XCOR:DOG:408:RAMPTIME_LEFT NMS")
 field(OUT,  "XCOR:DOG:408:RAMPDONE PP")
}

record(bo, "XCOR:DOG:408:RAMPDONE") {
 field(DESC, "Ramp time expired")
 field(DOL, "XCOR:DOG:408:RAMPDONE_CALC")
 field(OMSL, "closed_loop")
 field(ZNAM, "Done")
 field(ONAM, "Ramping")
}

record(bo, "XCOR:DOG:408:TRIMIFINTOL") {
  field(DESC, "Trim if in tolerance")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}

record(ao, "XCOR:DOG:408:DACZERORAMPTIME") {
  field(DESC, "DAC Zero ramp time (sec)")
  field(EGU, "sec")
  field(DRVH, "120")
  field(DRVL, "0")
  field(HOPR, "120")
  field(LOPR, "0")
  field(VAL,  "0")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:408:STDZINIT") {
  field(DESC, "Proc. Stdz PVs on boot")
  field(PINI, "YES")
  field(DOL1,  "1")
  field(DOL2,  "1")
  field(DOL3,  "1")
  field(LNK1, "XCOR:DOG:408:DEBUG.PROC PP")
  field(LNK2, "XCOR:DOG:408:STDZCYCLENUM.PROC PP")
  field(LNK3, "XCOR:DOG:408:STDZDISABLE.PROC PP")
  field(LNK4, "XCOR:DOG:408:STDZSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - minimum current set point
#  B - maximum current set point
#  C - final current set point
#  D - Number of cycles, where one cycle is min to max for stdzdirect=up (0)
#      or from imax to imin for stdzdirect=down (1).
#         The total number of set points would be 2*D+1
#  E - Standardize direction (up=0,down=1). The standardize direction
#      is defined by magnet measurements (MMF). For lcls, all magnets
#      are standardized in the up direction, which means that the standardize
#      cycle would starts at imin to imax. If the direction was down, then the standardize
#      cycle would start from imax to imin.
#  F - Standardize disabled (0=enabled, 1=disabled)
#  G - Debug flag from the pv <device>:DEBUG
#
# The standardize function is available for all controllable devices, but it is
# typically only used for larger magnets (steel),  powered by high current
# supplies. These magnets tend to build up a residual field over time. This would
# typically dipoles and quadrupoles. Saying this, the undulator quadrupoles, powered by 2A supplies
# and these magnets are standardized. Therefore, to get a complete list of magnets that
# should bestandardized for consulte the LCLS PRD 1.1-015, which  provides a list, This
# document also provides a list of standardize magnet groups, number of cycles, standardize
# ramprates and settle times.
#
#  A: <dev>:STDZIMIN
#  B: <dev>:STDZIMAX
#  C: <dev>:STDZIFINAL
#  D: <dev>:STDZCYCLENUM
#  E: <dev>:STDZDIRECT
#  F: <dev>:STDZDISABLE
#  G: <dev>:DEBUG
#
# The success or failure of the standardize function is set
# in the pv <dev>:STDZOK, and the magnet is restored to the
# desired b-field <dev>:BDES.
#
#  <dev>:STDZOK  (1=successfuly completed, 0=failed)
#
# The standardize function is available for individual magnets,
# or the main (defined in db) of a string. Some indiviaul magnets are grouped
# with a magnet string, such as boosts, trims or sometimes magnets
# nearby a large magnet string. These groupings are defined in the
# PRD 1.1-015.
#
# This PV is processed by <dev>:STDZIFINAL
record(aSub, "XCOR:DOG:408:STDZSUB") {
  field(DESC, "Stdz subroutine")
  field(INAM, "mgntStdzInit")
  field(SNAM, "mgntStdz")
  field(BRSV, "INVALID")

  field(INPA, "XCOR:DOG:408:STDZIMIN NPP NMS")
  field(INPB, "XCOR:DOG:408:STDZIMAX NPP NMS")
  field(INPC, "XCOR:DOG:408:STDZIFINAL NPP NMS")
  field(INPD, "XCOR:DOG:408:STDZCYCLENUM NPP NMS")
  field(INPE, "XCOR:DOG:408:STDZDIRECT.RVAL NPP NMS")
  field(INPF, "XCOR:DOG:408:STDZDISABLE.RVAL CPP NMS")
  field(INPG, "XCOR:DOG:408:DEBUG.RVAL NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "LONG")
  field(FTE, "ULONG")
  field(FTE, "ULONG")
  field(FTG, "ULONG")

# Outputs:
#  OUTA: set point waveform
#  OUTB: mgntStdz status message
# Note: the aSub sets the NORD field fo the
# waveform record based on the value in NOVA.
#
# If NOVA changes, make sure that <dev>:STDZWF.NELM
# is equal or greater than <dev>:STDZSUB.NOVA
#
  field(OUTA, "XCOR:DOG:408:STDZWF PP")
  field(OUTB, "XCOR:DOG:408:STDZMSG PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(NOVA, "21")

# On boot disable this PV from processing,
# enabled processing from the pv
# <dev>:STDZINIT, after all input pvs
# have been processed.
  field(DISV, "0")
  field(FLNK, "XCOR:DOG:408:STDZWF")
}

record(mbbo, "XCOR:DOG:408:STDZMSG") {
  field(DESC, "STDZSUB pv status")
  field(NOBT, "2")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "Unexepcted data type")
}

# This is the standardize waveform, generated by
# the <device>:STDZSUB
# Note: <dev>:STDZWF.NELM must be equal or greater than <dev>:STDZSUB.NOVA
record(waveform, "XCOR:DOG:408:STDZWF") {
  field(DESC, "Stdz Setpts")
  field(NELM, "21")
  field(FTVL, "DOUBLE")
}

#
# METHOD TO RESTORE A MULTI-BIT BINARY OUT and BO's
# 1. DON'T DEFINE DOL
# 2. SET PINI TO YES
# 3. RESTORE THE VAL FIELD
# ON THE VERY FIRST BOOT YOU MUST DO
# A CAPUT TO THE MBBO AND THEN ON REBOOT
# THE UDF WILL BE SET TO 0 AND THE VALUE
# WILL BE RESTORED PROPERLY.
#
# IMPORTANT:
# IF YOU DO NOT DO A CAPUT ON THE VERY FIRST BOOT, THE UDF
# WILL BE SET TO 1 AND THE STAT/SEVR WILL BE
# SET TO INVALID. THE INVALID STATE IS LOOKED
# AT ON REBOOT BY THE RESTORE PROGRAM AND THE MBBO
# WILL NOT BE RESTORED. SO IT'S VERY IMPORTANT TO DO
# THE INITAL CAPUT. THIS METHOD ALSO WORKS FOR BOs.
# NOTE THAT ANALOG OUTUPTS ARE ARE RESTORED IN THE
# SAME MANNER SO THE VAL CAN BE RESTORED PROPERLY.
#
record(bo, "XCOR:DOG:408:STDZMAINPS") {
  field(DESC, "Stdz by main or self")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "SELF")
  field(ONAM, "MAIN")
}

record(bo, "XCOR:DOG:408:STDZPS") {
  field(DESC, "PS state after Stdz")
  field(PINI, "YES")
  field(ZNAM, "On")
  field(ONAM, "Off")
  field(DTYP, "Soft Channel")
}

# This pv is processed when starting and completing a standardize or degauss
# function. At the start of each function the trims and/or related magnets are zeroed (2)
# After the function has completed the trims and/or related magnets are trimmed (1).
#
# For strings with related magnets, such as trim coils or
# nearby magents, specifed in the Magnet standardize PRD.
# In this case, the string main the pv
# STDZSLAVESGO is defined using the template
# mgnt_string_ctrl.template, where the INP argument is set to
# STDZGO.RVAL CPP, processing on change.
record(mbbo, "XCOR:DOG:408:STDZGO") {
  field(DESC, "Stdz trims")
  field(NOBT, "2")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "DAC_ZERO")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "8")
}

record(bo, "XCOR:DOG:408:STDZOK") {
  field(DESC, "Standarize Successful")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(stringout, "XCOR:DOG:408:STDZTOD") {
  field(DESC, "Successful Standardize Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:DOG:408:STDZLOSTTOD") {
  field(DESC, "Standardize Lost Time")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, " ")
  info(autosaveFields,"VAL")
}

record(longout, "XCOR:DOG:408:STDZCYCLECNT") {
  field(DESC, "Cycle Count")
  field(PINI, "YES")
}

record(longout, "XCOR:DOG:408:STDZCYCLENUM") {
  field(DESC, "No. Standardize Cycles")
  field(VAL,  "3")
  field(HOPR, "10")
  field(LOPR, "0")
  field(DRVH, "10")
  field(DRVL, "0")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:408:STDZDIRECT")
}

# The default standardize direction is "UP" for
# all LCLS Magnets..
record(bo, "XCOR:DOG:408:STDZDIRECT") {
  field(DESC, "Standardize Direction ")
  field(ZNAM, "UP")
  field(ONAM, "DOWN")
  field(VAL,  "0")
  field(FLNK, "XCOR:DOG:408:STDZIMIN")
}

record(ao, "XCOR:DOG:408:STDZIMIN") {
  field(DESC, "Min-STDZ Current")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL,  "-1")
  field(FLNK, "XCOR:DOG:408:STDZIMAX")
}

record(ao, "XCOR:DOG:408:STDZIMAX") {
  field(DESC, "Max. Standarize Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL,  "1")
  field(FLNK, "XCOR:DOG:408:STDZIFINAL")
}

record(ao, "XCOR:DOG:408:STDZIFINAL") {
  field(DESC, "Final SDTZ Current")
  field(DTYP, "Soft Channel")
  field(PREC, "1")
  field(EGU,  "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL,  "-1")
  field(FLNK, "XCOR:DOG:408:STDZSUB")
}

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
record(ao, "XCOR:DOG:408:STDZITOLR") {
  field(DESC, "Stdz tolerance min")
  field(DTYP, "Soft Channel")
  field(PREC, "5")
  field(DRVL, "0.05")
  field(DRVH, "10.0")
  field(VAL,  "0.1")
  field(EGU,  "%")
  field(PINI, "YES")
}

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
record(calc, "XCOR:DOG:408:STDZITOL") {
  field(DESC, "Stdz min tolerance")
  field(PREC, "5")
  field(CALC, "MAX(ABS(A),ABS(B))*C")
  field(INPA, "XCOR:DOG:408:STDZIMIN CP NMS")
  field(INPB, "XCOR:DOG:408:STDZIMAX CP MMS")
  field(INPC, "0.05")
  field(INPD, "XCOR:DOG:408:STDZITOLR CP MMS")
  field(EGU,  "A")
  field(FLNK, "XCOR:DOG:408:IDELTAS")
  field(PINI, "YES")
}

# D - factor (3.154/2 = 1.577) for EPSC, otherwise, set to 1.0
record(calc, "XCOR:DOG:408:STDZDLY") {
  field(DESC, "Ramp time for stdz cycle")
  field(CALC, "C>0?MAX(1,ABS((A-B)/C)*D):0")
  field(INPA, "XCOR:DOG:408:STDZIMIN CP NMS")
  field(INPB, "XCOR:DOG:408:STDZIMAX CP NMS")
  field(INPC, "XCOR:DOG:408:TRIMRAMPRATE CP NMS")
  field(INPD, "1.0")
  field(PREC, "5")
  field(EGU,  "sec")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:408:STDZRAMPDLY") {
  field(DESC, "Ramp delay total")
  field(CALC, "MAX(1,((A/100)*B+B))")
  field(PREC, "5")
  field(INPA, "XCOR:DOG:408:TRIMDLYPCT CP MS")
  field(INPB, "XCOR:DOG:408:STDZDLY CP MS")
  field(EGU, "sec")
}

# Meeting 4/22/2011 Loos, Sullivan decided to wait 1 sec
# Note: see note in mgntCtrl.st, mgntCtrl_settle_wait
record(calc, "XCOR:DOG:408:STDZMINIDLY") {
  field(DESC, "Mini-stdz delay")
  field(CALC, "A")
  field(PREC, "5")
  field(A,    "1.0")
  field(EGU, "sec")
  field(PINI, "YES")
}

record(ao, "XCOR:DOG:408:STDZMINIPCT") {
  field(DESC, "Mini Stdz percent")
  field(DTYP, "Soft Channel")
  field(VAL, "5.0")
  field(EGU, "%")
  field(PREC, "2")
  field(DRVH, "15.0")
  field(DRVL, "0.0")
  field(HOPR, "15.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:408:STDZMINIDELTA") {
  field(DESC, "Stdz mini % of IMAX")
  field(CALC, "(B/100)*(A-C)")
  field(INPA, "XCOR:DOG:408:IDES.HOPR")
  field(INPB, "XCOR:DOG:408:STDZMINIPCT CPP NMS")
  field(INPC, "XCOR:DOG:408:IDES.LOPR")
  field(PREC, "5")
}

record(calc, "XCOR:DOG:408:STDZMINISETPT") {
  field(DESC, "Mini Stdz delta")
  field(CALC, "C==0?MAX(E-D,B):MIN(E+D,A)")
  field(INPA, "XCOR:DOG:408:IDES.HOPR")
  field(INPB, "XCOR:DOG:408:IDES.LOPR")
  field(INPC, "XCOR:DOG:408:STDZDIRECT.RVAL")
  field(INPD, "XCOR:DOG:408:STDZMINIDELTA")
  field(INPE, "XCOR:DOG:408:IDES")
  field(PREC, "5")
  field(FLNK, "XCOR:DOG:408:STDZMINISETPTOOR")
}

# This PV is 1 if STDZMINISETPT is out of range (greater than
# IDES.HOPR or less than IDES.LOPR) and 0 otherwise.
record(calc, "XCOR:DOG:408:STDZMINISETPTOOR") {
  field(DESC, "Mini Stdz setpoint out of range")
  field(CALC, "C==0?(E-D<B):(E+D>A)")
  field(INPA, "XCOR:DOG:408:IDES.HOPR")
  field(INPB, "XCOR:DOG:408:IDES.LOPR")
  field(INPC, "XCOR:DOG:408:STDZDIRECT.RVAL")
  field(INPD, "XCOR:DOG:408:STDZMINIDELTA")
  field(INPE, "XCOR:DOG:408:IDES")
  field(PREC, "5")
}

# DR 4/2011 add these 2 records for perturb slider
# If currently standardized and we are moving opposite
# to the direction of standardization, then clear STDZOK
# and not the time that standardize was lost in STDZTOD.
# However, if standardization has already been lost don't
# change the standardize lost date or bother to clear STDZOK.
# To enable STDZ, STDZDISABLE = 0 = Enabled
#
# AL 7/2022 lose standardize only if out of tolerance
# AL 10/2022 do not lose standardize if IACT is invalid
# AL 10/2023 lose standardize if turned off even if not
#            out of tolerance
#
# This PV is processed by <dev>:BCTRLGO and a change in <dev>:STATE
record(calcout, "XCOR:DOG:408:CHECKSTDZLOST") {
  field(DESC, "Check if stdz is lost")

  field(CALC, "(G=3||I=3)?0:C=1&&D=0&&((H=1&&A#B)||(E=0))?3:0")
  field(INPA, "XCOR:DOG:408:IADJUST.RVAL")
  field(INPB, "XCOR:DOG:408:STDZDIRECT.RVAL")
  field(INPC, "XCOR:DOG:408:STDZOK.RVAL")
  field(INPD, "XCOR:DOG:408:STDZDISABLE.RVAL")
  field(INPE, "XCOR:DOG:408:STATE.RVAL CPP NMS")
  field(INPF, "XCOR:DOG:408:ICTRL.RVAL")
  field(INPG, "XCOR:DOG:408:STATE.SEVR")
  field(INPH, "XCOR:DOG:408:BDELTAS.M")
  field(INPI, "XCOR:DOG:408:IACT.SEVR")
  field(OUT,  "XCOR:DOG:408:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "Transition To Non-zero")
}

record(seq, "XCOR:DOG:408:STDZLOSTGO") {
  field(DESC, "Process lost stdz")
  field(SELM, "Mask")
  field(DOL1, "1")
  field(DOL2, "0")
  field(LNK1, "XCOR:DOG:408:STDZLOSTTOD.PROC")
  field(LNK2, "XCOR:DOG:408:STDZOK PP")
}

# Record maximum current after standardize
# Reset to IACT from sequence after trim
# Disable processing during (mini-)standardize or trim
record(calc, "XCOR:DOG:408:STDZIACTMAX") {
  field(DESC, "Max act current after stdz")
  field(CALC, "MAX(A, B)")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:408:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:DOG:408:IACT CP")
  field(INPB, "XCOR:DOG:408:STDZIACTMAX")
  field(EGU,  "A")
  field(FLNK, "XCOR:DOG:408:CHECKPWRDIP")
}

# Detect power dip if STDZOK is YES, STDZ is enabled, and IACT is valid
# If IACT drops below STDZIACTMAX by more than the trim tolerance, clear STDZOK

# Warning: Take the absolute value of the trim tolerance, or else quads of
# negative polarity will always lose STDZ since their IDELTAS.I are negative.

# Note: Large quads and bends are prone to losing STDZ even if they are
# perturbed toward higher current since their current tends to overshoot
# by greater than the trim tolerance before settling down.
record(calcout, "XCOR:DOG:408:CHECKPWRDIP") {
  field(DESC, "Detect power dip")
  field(CALC, "(A-B>ABS(C))?3:0")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:408:CHECKPWRDIP_ENABLE")
  field(INPA, "XCOR:DOG:408:STDZIACTMAX")
  field(INPB, "XCOR:DOG:408:IACT")
  field(INPC, "XCOR:DOG:408:IDELTAS.I")
  field(OUT,  "XCOR:DOG:408:STDZLOSTGO.SELN PP NMS")
  field(OOPT, "When Non-zero")
}

# Enable processing of STDZIACTMAX and CHECKPWRDIP only if
# STDZOK = YES, STDZDISABLE = NO, CTRL != Trim (2), and
# CTRL != Stdz (4)
record(calc, "XCOR:DOG:408:CHECKPWRDIP_ENABLE") {
  field(CALC, "A&&!B&&(C#2)&&(C#4)")
  field(INPA, "XCOR:DOG:408:STDZOK.RVAL CP")
  field(INPB, "XCOR:DOG:408:STDZDISABLE.RVAL CP")
  field(INPC, "XCOR:DOG:408:CTRL.RVAL CP")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# Set by sequence during calibration. The values
# ZRVL-EIST must match #defines in mgntCtrl.h
record(mbbo, "XCOR:DOG:408:CALBSTATE") {
  field(DESC, "Calibration State")
  field(PINI, "YES")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Waiting")
  field(THST, "Not used")
  field(FRST, "Unavailable")
  field(FVST, "Ramp timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(VAL, "0")
}

# Set OMSL to closed_loop, and don't restore on boot for any ps controllers.
# EPSC's have auto calibrate in the firmware and return the calibration state
# MCOR's, Bulks and Pulsed Magnests don't use the dac calibration provided by the sequence
# EMCOR's have good resolution and don't require the dac calibration provided the sequence.
# Otherwise set OMSL to closed_loop for EPSCs and get value from controller.
record(bo, "XCOR:DOG:408:CALBOK") {
  field(DESC, "Successful Calibration")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If CALBOK=1 AND Calibrate is enabled AND Calibrate SLOPE > 0
# then DOL1...DOL5 will be written to LNK1...LNK5 (0x1f=31) in CALB_SEQ.
# Otherwise, DOL6...DOLA will be written to LNK6...LNKA (0x3c0=960) in CALB_SEQ
#
record(calcout, "XCOR:DOG:408:CALBSET") {
  field(DESC, "Use DAC Calbration")
  field(SCAN, "10 second")
  field(CALC, "A&&(B==0)&&C?31:960")
  field(INPA, "XCOR:DOG:408:CALBOK")
  field(INPB, "XCOR:DOG:408:CALBDISABLE")
  field(INPC, "XCOR:DOG:408:CALBSLOPE")
  field(OOPT, "On Change")
  field(OUT, "XCOR:DOG:408:CALB_SEQ.SELN PP")
}

# Set LINR=NO_CONVERSION (0) or LINR=LINEAR (2)
# If no conversion is used then RVAL=ASLO*VAL + AOFF to 
# convert from volts to dac counts
# if linear is used then RVAL=ASLO*ESLO*VAL + AOFF + EOFF
#
record(seq, "XCOR:DOG:408:CALB_SEQ") {
  field(DESC, "Output Calib Values")
  field(SELM, "Mask")
  field(SELL, "XCOR:DOG:408:CALBSET")
#
# Use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0    Disable record processing
#   <PS>:VSETPT.ASLO <DEV>:CALBSLOPE
#   <PS>:VSETPT.AOFF <DEV>:CALBOFFFSET
#   <PS>:VSETPT.LINR  0   "NO CONVERSION"
#   <PS>:VSETPT.DISA  1    Enable record processing
  field(DOL1, "1")
  field(DOL2, "XCOR:DOG:408:CALBSLOPE")
  field(DOL3, "XCOR:DOG:408:CALBOFFSET")
  field(DOL4, "0")
  field(DOL5, "0")
  field(LNK1, "")
  field(LNK2, "")
  field(LNK3, "")
  field(LNK4, "")
  field(LNK5, "")
#
# Don't use calibration values. 
# Set Power Supply Controller PVs
#   <PS>:VSETPT.DISA  0  Disable record processing
#   <PS>:VSETPT.ASLO  0
#   <PS>:VSETPT.AOFF  0
#   <PS>:VSETPT.LINR  2 "LINEAR" 
#   <PS>:VSETPT.DISA  1  Enable record processing
  field(DOL6, "1")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "2")
  field(DOLA, "0")
  field(LNK6, "")
  field(LNK7, "")
  field(LNK8, "")
  field(LNK9, "")
  field(LNKA, "")
}

record(stringout, "XCOR:DOG:408:CALBTOD") {
  field(DESC, "Calibration Success Time")
  field(PINI, "YES")
#  field(DOL, "")
  field(OMSL, "supervisory")
  field(DTYP, "Soft Channel")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:408:CALBWAITTIME") {
  field(DESC, "Settle time per point")
  field(PINI, "YES")
  field(EGU, "sec")
  field(DRVH, "10.0")
  field(HOPR, "10.0")
  field(DRVL, "1.0")
  field(LOPR, "1.0")
  field(VAL, "1.0")
}

# Indicate if the linear square fit
# used in calculating the dac slope and offset
# was good (0 is worse case, while 1 is best).
record(ao, "XCOR:DOG:408:CALBGOODFIT") {
  field(DESC, "Calibration Fit Successful")
  field(PINI, "YES")
  field(HOPR, "1.0")
  field(DRVH, "1.0")
  field(EGU, "A")
}

# Calculated slope used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.ASLO
# and NO CONVERSION is used
#
record(ao, "XCOR:DOG:408:CALBSLOPE") {
  field(DESC, "Calc DAC Slope")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

# Calculated offset used to convert Volts to DAC Counts
# When CALBOK=1 and CALBDISABLE=0 then
# CALBSLOPE -> <mcor>:VSETPT.AOFF
# and NO CONVERSION is used
#
record(ao, "XCOR:DOG:408:CALBOFFSET") {
  field(DESC, "Calc DAC Offset")
  field(PREC, "6")
  field(EGU,  "Counts")
  field(PINI, "YES")
}

record(bo, "XCOR:DOG:408:CALBUSEDEFAULT") {
  field(DESC, "Use default Offset")
  field(DTYP, "Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(VAL,  "0")
}

# Default slope used in conversion from Volts to DAC Counts
record(ao, "XCOR:DOG:408:DACSLOPE") {
  field(DESC, "V to DAC slope")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:408:DACOFFSET")
}

# Default Offset used in conversion from Volts to DAC Counts
record(ao, "XCOR:DOG:408:DACOFFSET") {
  field(DESC, "V to DAC offset")
  field(PREC, "6")
  field(EGU, "V")
  field(DOL,  "")
  field(OMSL, "supervisory") 
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:408:CALCDAC")
}

# Calculated DAC Counts from measured current IACT.
# A = Setpoint I to V Slope
# B = Setpoint I to V Offset
# C = Measured Current 
# D = V to DAC Offset
# E = V to DAC Offsest (0)
record(calc, "XCOR:DOG:408:CALCDAC") {
  field(DESC, "IACT to DAC Counts")
  field(CALC, "D=0?0:(((C*A)+B)-E)/D")
  field(INPA, "")
  field(INPB, "0.0")
  field(INPC, "XCOR:DOG:408:IACT")
  field(INPD, "XCOR:DOG:408:DACSLOPE")
  field(INPE, "XCOR:DOG:408:DACOFFSET")
  field(EGU, "Counts")
  field(PREC, "6")
}

record(ao, "XCOR:DOG:408:DAC") {
  field(DESC, "DAC Set point")
  field(EGU, "Counts")
  field(DOL, "")
  field(OMSL, "supervisory")
  field(PREC, "6")
  field(PINI, "YES")
}


record(ao, "XCOR:DOG:408:CALBIMIN") {
  field(DESC, "Calibration Min Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "1")
  field(HOPR, "1")
  field(DRVL, "-1")
  field(LOPR, "-1")
  field(PREC, "3")
  field(EGU, "A")
  field(VAL, "0.0")
  field(FLNK, "XCOR:DOG:408:CALBIMAX")
}

record(ao, "XCOR:DOG:408:CALBIMAX") {
  field(DESC, "Calibration Max Setpoint")
  field(DTYP, "Soft Channel")
  field(PREC, "3")
  field(DRVH, "1")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVL, "-1")
  field(EGU,  "A")
  field(VAL,  "1")
  field(FLNK, "XCOR:DOG:408:CALBSTEPNUM")
}

record(ao, "XCOR:DOG:408:CALBIFINAL") {
  field(DESC, "Calibration Last Setpoint")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU, "A")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(VAL, "0")
}

record(longout, "XCOR:DOG:408:CALBSTEPNUM") {
  field(DESC, "No. of CALB steps")
  field(HOPR, "10")
  field(DRVH, "10")
  field(DRVL, "3")
  field(LOPR, "3")
  field(DOL,  "6")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:DOG:408:CALBIDELTA")
}

record(calc, "XCOR:DOG:408:CALBIDELTA") {
  field(DESC, "Step size for CALB")
  field(CALC, "C=0?0:ABS((A-B)/C)")
  field(INPA, "XCOR:DOG:408:CALBIMAX")
  field(INPB, "XCOR:DOG:408:CALBIMIN")
  field(INPC, "XCOR:DOG:408:CALBSTEPNUM")
  field(EGU, "A")
}

# This is the current multiplier between
# the current input and output. For example,
# the maximum output current on an MCOR6 (6A)
# would expect a maximum readback current of 12A, 
# the multiplier would be 2.
# On the other hand, for an MCOR12, both the
# maximum output current and input current are 12A,
# the multiplier would be 1.
record(calc, "XCOR:DOG:408:CALBIMULT") {
  field(DESC, "IACT vs ISETPT mult")
  field(CALC, "C#0||A=0?1:ABS(B/A)")
  field(INPA, "MCOR:EXT:216:ISETPT.DRVH")
  field(INPB, "MCOR:EXT:216:IACT.HOPR")
  field(INPC, "XCOR:DOG:408:PSCONTROLLER.RVAL CPP")
  field(EGU,  "A")
  field(PINI, "YES")
}

# SNL dbputs DAC values here. 6-10 steps are possible.
record(waveform, "XCOR:DOG:408:CALBICTRLWF") {
  field(DESC, "ICTRL setpoint array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:DOG:408:DACWF") {
  field(DESC, "DAC count array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:408:DACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:408:DACSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:408:DACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# SNL dbputs Calulated DAC values from IACT using the measured
# slope and offset.  6-10 steps are possible.
record(waveform, "XCOR:DOG:408:CALCDACWF") {
  field(DESC, "Calc DAC counts array")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:408:CALCDACSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:408:CALCDACSA") {
  field(DESC, "Calc DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:408:CALCDACWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

# The points on the line. Used to calculate the residuals
# calbywf[i] = calbslope * calbiactwf[i] + calboffset
record(waveform, "XCOR:DOG:408:CALBYWF") {
  field(DESC, "mx + b")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:408:CALBYSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:408:CALBYSA") {
  field(DESC, "DAC counts")
  field(DTYP, "Soft Channel")
  field(INP, "XCOR:DOG:408:CALBYWF")
  field(MALM, "10")
  field(NELM, "6")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
}

record(waveform, "XCOR:DOG:408:CALBIACTWF") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(NELM, "10")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:408:CALBIACTSA")
}

# Used only for xygraph edm plot
record(subArray, "XCOR:DOG:408:CALBIACTSA") {
  field(DESC, "Actual current")
  field(DTYP, "Soft Channel")
  field(MALM, "10")
  field(NELM, "6")
  field(INP, "XCOR:DOG:408:CALBIACTWF")
  field(INDX, "0")
  field(FTVL, "DOUBLE")
  field(FLNK, "XCOR:DOG:408:CALBLIMITS")
}

# Check that measured current during calibration is within
# tolerance.
record(aSub, "XCOR:DOG:408:CALBLIMITS") {
  field(DESC, "Calb tolerance check")
  field(INAM, "mgntCalbLimitsInit")
  field(SNAM, "mgntCalbLimits")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - minimum current tolerance
# E - maximum current tolerance
# F - stdz absolute current tolerance on ides-iact
# G - stdz fractional tolerance of max current
# H - <device>:VSETPT.ESLO  - slope used to convert volts to dac counts
# I - iact vs isetpt multiplier
#
  field(INPA, "XCOR:DOG:408:CALBSTEPNUM")
  field(INPB, "XCOR:DOG:408:CALBIACTWF")
  field(INPC, "XCOR:DOG:408:CALBICTRLWF")
  field(INPD, "0.5")
  field(INPE, "2.0")

# Loose tolerance on desired current-ADC measured current.
# used for calibration and standardize. This is an
# absolute tolerance with the default set to 10 percent.
# Note: in slc ATOL(1), absolute tolerance
  field(INPF, "XCOR:DOG:408:STDZITOLR")

# Loose tolerance on desired current-adc measured current.
# used for calibration and standardize. The tolerance
# is a percentage (INPC=5%) of the maximum current. Note that
# we have bipolar supplies, so the absolute value of
# the min and max current is taken.
# Note: in slc ATOL(2), fractional tolerance
  field(INPG, "XCOR:DOG:408:STDZITOL")

  field(INPH, "XCOR:DOG:408:DACSLOPE")
  field(INPI, "XCOR:DOG:408:CALBIMULT")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "DOUBLE")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - in tolerance flag (1=ok, 0=bad)
#  VALB - current ratio
#  VALC - tolerance for calibrated dac y-intercept from linear sq. fit
#  VALD - tolerance for calibrated dac slope from linear sq. fit
#
  field(FTVA, "ULONG")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
}

# Linear Square Fit. This record is processed by the SNL
record(aSub, "XCOR:DOG:408:CALBFITLSQ") {
  field(DESC, "Linear Sq Fit")
  field(INAM, "subSysFitLSqInit")
  field(SNAM, "subSysFitLSq")
#
# Inputs:
# A - is the number of points (npts)
# B - is the Y-axis
# C - is the X-axis
# D - not used
# E - not used
# F - debug flag (1=debug mod, 0=normal mode) (optional)
#
  field(INPA, "XCOR:DOG:408:CALBSTEPNUM")
  field(INPB, "XCOR:DOG:408:CALBIACTWF")
  field(INPC, "XCOR:DOG:408:DACWF")
  field(INPF, "XCOR:DOG:408:DEBUG.RVAL")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTF, "ULONG")
  field(NOB, "10")
  field(NOC, "10")
#
# Outputs:
#  VALA - the constant term (y-intecept)
#  VALB - the X-Coefficient (slope)
#  VALC - the measure of goodness of fit
#
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(BRSV, "INVALID")
}


#! TextBox(TB7,980,160,1420,460,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nEGU = Engineering Units \nDRVH, DRVL  = High and Low Drive Limits\n      NOTE: DRVH, DRVL same as IMMO in the SLC database\nHIHI, LOLO    = High and Low Limits for \n                        Standardization and Calibration\n      NOTE: HIHI, LOLO same as IMMS in the SLC database\nPREC = Precision (# after the decimal point)\nNOTE: ADEL is the same as ATOL[1] in the SLC database.\nHYST = Readback Alarm Hysterisis\nDVI1 = offset polynomial of DVI\nDVI2 = slop polynomial of DVI",null)
#! TextBox(TB4,1560,420,2000,680,0,"Dialog",12,1,16777215,"The fields in the SLOPE and OFFSET records are used when \nconverting I to DAC counts using linear conversion,  \nVAL = OFFSET + SLOPE * x\n\nThe sel records choose between the calculated (theoretical)\nhard-coded values, or the values measured from calibration.\nThe output of the sel records connect to the ESLO and EOFF\nDAC channels for MCOR type devices. Selection is governed by\nthe XCOR:DOG:408CALBOK record, which flinks to the sel records\n",null)
#! TextBox(TB3,1000,100,1340,140,0,"Dialog",24,1,16777215,"Calibrated Devices\n",null)
#! TextBox(TB1,1280,440,1480,540,0,"Dialog",12,1,16777215,"CALBGOODFIT is written to by the CALB SNL\nupon successful calibration.\n(CALBOK is also written to by the CALB SNSL\nupon sucessful calb.)",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND

record(dfanout, "XCOR:DOG:408:DEGAUSINIT") {
  field(DESC, "Proc. Degauss PVs on boot")
  field(PINI, "YES")
  field(DOL,  "1")
  field(OUTA, "XCOR:DOG:408:DEGAUSIMIN.PROC PP")
  field(OUTB, "XCOR:DOG:408:DEGAUSIMAX.PROC PP")
  field(OUTC, "XCOR:DOG:408:DEGAUSTYPE.PROC PP")
  field(OUTD, "XCOR:DOG:408:DEGAUSSTEP.PROC PP")
  field(OUTE, "XCOR:DOG:408:MADNAME.PROC PP")
  field(OUTF, "XCOR:DOG:408:PSTYPE.PROC PP")
  field(OUTG, "XCOR:DOG:408:DEGAUSSUB.DISV PP")
  field(ASG,  "Internal")
}

# Inputs:
#  A - Degauss minimum current, only used of E=Standard or Oscillating
#  B - Degauss maximum current, only used of E=Standard or Oscillating
#  C - Degauss type, (ref: element name in the LCLS Oracle Infrastructure)
#      Set to None unless <dev>:DEGUASMETHOD = Oscillating
#  D - Not used
#  E - Degauss method    (0=None , 1=standard, 2=Oscillating, 3=not used)
#  F - Power Supply type (0=bipolar, 1=unipolar, 2=unipolar with polarity switch, 3=none)
#  G - Debug flag from the pv <device>:DEBUG
#
# Degaussing is available for unipolar power supplies with a polarity switch.
# There are three types of degausing procedures used, the most common is the
# the Standard. This will generate a set of current set points that will ramp
# the power supply first to 0, and then cycle the current from a minimum to
# maximum current a number of times defined by the PVs, and then finally to 0 current
# as the last setpoint.
#
#  <dev>:DEGAUSCYCLENUM  -- Note: oly used for standard degauss method
#  <dev>:DEGAUSIMIN
#  <dev>:DEGAUSIMAX
#
# Finally the power supply is turned off and the
# degauss flaged as completed by setting the following PV.
#
#  <dev>:DEGAUSOK  (1=successfuly completed, 0=not degaussed)
#
# Note: currently only the BXHS, BXSS, BCXXL bend chicane magnets
# in the LCLS undulator. These magents use the osicllating methiod
# where a predefined set of points have been provided by
# Magnet Measurements (MMF) for degaussing.
#
#  <dev>:DEGAUSMETHOD  (e.g. None, Standard , Oscillation )
#  <dev>:DEGAUSTYPE    (e.g. BXHS2, BXSS2, BCXXL2 )
#
#  Note: Degauss is not available for unipolar power supplies
#  without a polarity switch (DTYP=3) Check PV <dev>:PSTYPE
#  to determine the type of power supply.
#
record(aSub, "XCOR:DOG:408:DEGAUSSUB") {
  field(DESC, "Degauss subroutine")
  field(INAM, "mgntDegaussInit")
  field(SNAM, "mgntDegauss")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:DOG:408:DEGAUSIMIN NPP NMS")
  field(INPB, "XCOR:DOG:408:DEGAUSIMAX NPP NMS")
  field(INPC, "XCOR:DOG:408:DEGAUSTYPE.RVAL NPP NMS")
  field(INPE, "XCOR:DOG:408:DEGAUSMETHOD.RVAL NPP NMS")
  field(INPF, "XCOR:DOG:408:PSTYPE NPP NMS")
  field(INPG, "XCOR:DOG:408:DEBUG.RVAL NPP NMS")
  field(INPH, "XCOR:DOG:408:DEGAUSSTEP NPP NMS")
  field(FTA, "DOUBLE")
  field(FTB, "DOUBLE")
  field(FTC, "ULONG")
  field(FTD, "ULONG")
  field(FTE, "ULONG")
  field(FTF, "USHORT")
  field(FTG, "ULONG")
  field(FTH, "DOUBLE")

# Outputs:
#  OUTA: Degauss set point waveform
#  OUTB: Status (0=success,1=None,2=output wf too small,3=invalid ps type,4=invalid method)
#  OUTC: Deguass number of cycles, where one cycle is min to max.
#      The number of data points would be
#         bipolar supplies:  (2*D)+2
#      where the additional 2 points are the starting and ending points, which is 0.
#         unipolar supplies with a polarity switch: 2*D
#
# Note: the aSub record sets the NORD field of the
# waveform record based on the value in NOVA.
#
  field(OUTA, "XCOR:DOG:408:DEGAUSWF PP")
  field(OUTB, "XCOR:DOG:408:DEGAUSMSG PP")
  field(OUTC, "XCOR:DOG:408:DEGAUSCYCLENUM PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "USHORT")
  field(FTVC, "ULONG")
  field(NOVA, "60")

# On boot disable this PV from processing.
# Processing will be enabled by the pv
# <dev>:DEGAUSINIT, after all input pvs
# have been processed.
  field(DISV, "0")
}

# This is the degauss waveform generated by
# the <device>:DEGAUSSUB
record(waveform, "XCOR:DOG:408:DEGAUSWF") {
  field(DESC, "Degauss Setpts")
  field(NELM, "60")
  field(FTVL, "DOUBLE")
}

record(mbbo,"XCOR:DOG:408:DEGAUSMSG") {
  field(DESC, "Degauss Status Msg")
  field(NOBT, "3")
  field(ZRST, "Success")
  field(ONST, "None")
  field(TWST, "Wf too small")
  field(THST, "PS is not bipolar")
  field(FRST, "Unknown Degauss Type")
  field(TWSV, "MINOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
}


# Using the default degauss method of "Standard"
# number of full cycle is 1, which equals 4 data points
# for a bipolar supply and 5 data points for a unipolar
# supply with a polarity switch. For the method "Oscillating"
# the default number of full cycles is 25, which equals
# 52 data points.
# Note: this pv is populated by <dev>:DEGAUSSUB
record(longout, "XCOR:DOG:408:DEGAUSCYCLENUM") {
  field(DESC, "No. Degauss Cycles")
  field(HOPR, "27")
  field(DRVH, "30")
  field(LOPR, "0")
  field(PINI, "YES")
}

# Number of full cycles done during the degauss
# Note: This pv is set by the sequence mgntCtrl.st during
# the degauss procedure.
record(longout, "XCOR:DOG:408:DEGAUSCYCLECNT") {
  field(DESC, "Degauss Cycle Count")
  field(PINI, "YES")
}

# The DEGAUSSLAVESGO pv is used to force processing of a set of related magnets as the first step
# of degaussing the main. These related magnest, in this case the trim coils, are DAC_ZEROed,
# the the  main is degaussed, afterwhich the trim coils are TRIMmed to their BDES value,
# the main is turned off and the DEGAUSOK flag set to true.
#
# NOTE: Only when the DEGAUSOK flag is false and the main is turned off, will a minor alarm
# be set and the summary message (STATAMSG) indicate a degauss warning.
#
# When the main is turned on and the DEGAUSOK flag is set to false, this case is considered
# a major alarm. Note that some ps have on/off control and others do not. For example,
# QSM1 does not have on/off control and so the supply is left on after degaussing.
# However, for HXRSS,SXRSS and 50B1 these do have on/off control and the check for degauss
# lost is different.
#
record(bo, "XCOR:DOG:408:DEGAUSOK") {
  field(DESC, "Degauss Successful")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# For a magnet hw configuration that does not permit
# the ps to be turned off after degaussing, such as QSM1,
# after degaussing the ps is set to zero Amps, and the
# and as long as the b-field limit remains below
# a limit BLIMIIT, the degauss is maintained. Otherwise,
# the degauss will  be lost.
record(ao, "XCOR:DOG:408:DEGAUSBLIMIT") {
  field(DESC, "B-field limit for degausok")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(DRVH, "20")
  field(VAL,  "0.06")
  field(PREC, "4")
}

record(ao, "XCOR:DOG:408:DEGAUSIMIN") {
  field(DESC, "Min. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(VAL,  "-1")
}
record(ao, "XCOR:DOG:408:DEGAUSIMAX") {
  field(DESC, "Max. Degauss I")
  field(PREC, "1")
  field(EGU,  "Amps")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(VAL,  "1")
}

# Degauss type
#
# 0=None
# 1=BCXH1
# 2=BCXSS1
# 3=BCXXL1
# 4=CRYO (Use data points from FERMI)
# 5=XCPEPX1
# 6=BCXCBX13
# 7=BCXCBX21
#
# Note: this pv is looked at in a function in
# thie field: mgntApp/src/mgntSub.c
record(mbbo,"XCOR:DOG:408:DEGAUSTYPE") {
  field(DESC, "Type Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "None")
  field(ONST, "BCXHS1")
  field(TWST, "BCXSS1")
  field(THST, "BCXXL1")
  field(FRST, "CRYO")
  field(FVST, "XCPEPX1")
  field(SXST, "BCXCBX13")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(FLNK, "XCOR:DOG:408:DEGAUSSUB")
  field(VAL,  "0")
}

#   Degauss method
#   None      -  Degauss not available.
#   Standard  - cycle up/down beween min and max, for ncycles,
#               defined in <dev>:DEGAUSCYCLENUM
#   Oscillate - oscillate between min and max, from the outer
#               limits towards zero, using a specified step size,
#               defined in <dev>:DEGAUSSTEP.
#               If this is sent then <dev>:DEAUSTYPE will be used.
#
record(mbbo,"XCOR:DOG:408:DEGAUSMETHOD") {
  field(DESC, "Method of Degauss")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "2")
  field(ZRST, "None")
  field(ONST, "Standard")
  field(TWST, "Oscillating")
  field(THST, "Unknown")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
}

# This is the degauss step size, which applies
# to the degauss type,or method "Oscillating",
# where the set of degauss points is generated
# starting from 0, and oscillating been max and
# min, decressing in step size towards zero.
# and ending at zero.
record(ao, "XCOR:DOG:408:DEGAUSSTEP") {
  field(DESC, "Degauss step size")
  field(DOL,  "0.88")
  field(EGU,  "Amps")
}

# Change to DEGAUSIRAMPRATE
# Need to change: psCtrl.h,
# To change default for degauss ramp rate
# use static restore file <nodename>_static.cwConfig
record(ao, "XCOR:DOG:408:DEGAUSRAMPRATE") {
  field(DESC, "Degauss Ramp rate ")
  field(PINI, "YES")
  field(PREC, "3")
  field(EGU,  "Amps/sec")
  field(HOPR, "30.0")
  field(DRVH, "30.0")
  field(DRVL, "0.001")
  field(LOPR, "0.001")
  field(VAL, "2")
}

# Settle time between step. If the degauss type
# or method "Standard" then the settle time
# will take place at the flat-top. If the
# method is "Oscillating" or "File" then
# the settle time after each step.
record(ao, "XCOR:DOG:408:DEGAUSSETL") {
  field(DESC, "Settle time after each step")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(PREC, "1")
  field(EGU, "sec")
  field(DRVL, "0.5")
  field(LOPR, "0.5")
  field(DRVH, "60.0")
  field(HOPR, "60.0")
  field(VAL,  "2")
}

record(stringout, "XCOR:DOG:408:DEGAUSTOD") {
  field(DESC, "Successful Degauss Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(stringout, "XCOR:DOG:408:DEGAUSLOSTTOD") {
  field(DESC, "Degauss Lost Time")
  field(DTYP, "Soft Channel")
  field(PINI, "YES")
  field(VAL,  " ")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:408:DEGAUSTIME") {
  field(DESC, "Time to complete")
  field(PINI, "YES")
  field(EGU,  "secs")
  field(OUT, "XCOR:DOG:408:DEGAUSTIME_MIN.A PP")
  info(autosaveFields,"VAL")
}
record(calc, "XCOR:DOG:408:DEGAUSTIME_MIN") {
  field(DESC, "Time to complete")
  field(CALC, "A?A/60:0")
  field(EGU,  "min")
  info(autosaveFields,"VAL")
}

# For degaussed magnets set the bdes of the trim coils
# to zero before degauss begins, so that after the degauss
# is complete they are trimmed to zero. For degaussed magnets
# with trim coils set the macros OUT1-4 to the following:
#   OUT1= <dev1>:BDES PP
#
# For magnets that do not have degauss use the macro
# OUTA-D setting to blank.
record(dfanout, "XCOR:DOG:408:DEGAUSGO") {
  field(DESC,  "Set bdes of btrms to zero")
  field(ASG,   "Internal")
  field(OUTA,  "")
  field(OUTB,  "")
  field(OUTC,  "")
  field(OUTD,  "")
}

# ===========  CRYO ONLY ===========

record(bo, "XCOR:DOG:408:DEGAUSAUTO") {
  field(DESC, "Perform an auto-degauss")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# Set Max Current while Magent is degaussed
#
# If the requested current is greater than imax (absolute),
# then the magnet will be trimmed and the imax updated to
# the requested current.
record(calcout, "XCOR:DOG:408:DEGAUS_IMAX_CHECK") {
  field(DESC, "Check if imax shoud chg")
  field(CALC, "(C==4)&&(ABS(B)>ABS(A))?1:0")
  field(INPA, "XCOR:DOG:408:DEGAUS_IMAX")
  field(INPB, "XCOR:DOG:408:ISETPT")
  field(INPC, "XCOR:DOG:408:DEGAUSTYPE.RVAL")
  field(OUT,  "XCOR:DOG:408:DEGAUS_IMAX_UPDATE.SELN")
  field(FLNK, "XCOR:DOG:408:DEGAUS_IMAX_UPDATE")
}
record(seq, "XCOR:DOG:408:DEGAUS_IMAX_UPDATE")
{
  field(DESC, "Degauss IMAX Update")
  field(SELM, "Specified")
  field(DOL1, "XCOR:DOG:408:ISETPT")
  field(LNK1, "XCOR:DOG:408:DEGAUS_IMAX PP")
}


# Set the maximum current after a successful
# degauss. This pv is updated by the
# sequence.
record(ao, "XCOR:DOG:408:DEGAUS_IMAX") {
  field(DESC, "Max I set afer a degauss")
  field(EGU,  "Amps")
  field(PINI, "YES")
  field(PREC, "6")
  field(HOPR, "1")
  field(LOPR, "-1")
  field(DRVH, "1")
  field(DRVL, "-1")
  field(VAL,  "1")
  field(FLNK, "XCOR:DOG:408:DEGAUS_IMAXPOL_CHECK")
  info(autosaveFields,"VAL,RVAL")
}

# Set the polarity if degauss_imax
record(calcout, "XCOR:DOG:408:DEGAUS_IMAXPOL_CHECK") {
  field(DESC, "Determine polarity of imax")
  field(CALC, "A>=0?0:1")
  field(INPA, "XCOR:DOG:408:DEGAUS_IMAX")
  field(FLNK, "XCOR:DOG:408:DEGAUS_IMAXPOL")
}
record(bo, "XCOR:DOG:408:DEGAUS_IMAXPOL") {
  field(DESC, "Polarity of imax I")
  field(DTYP, "Raw Soft Channel")
  field(DOL,  "XCOR:DOG:408:DEGAUS_IMAXPOL_CHECK")
  field(OMSL, "closed_loop")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  field(FLNK, "XCOR:DOG:408:DEGAUS_ABSIMAX")
  info(autosaveFields,"VAL RVAL")
}

# This is the maximum absoulte current
# that has been set after a degusss.
# Once the degauss has been lost the
# Absolute maximum current is no longer
# tracked until a degauss has been performed,
# at which point this pv will be reset.

# 1. If the requested current is greater than 85% of
# DEGAUSABSIMAX for a trim request, the trim
# the trim proceeds normally and DEGAUSABSIMAX
# woudl be updated to the new value.
#
# 2. However, if the requeted current is greater
# than 85% of DEGAUSABSIMAX but less than DEGUSABSIMAX,
# the magnetr would be trimmed normally but
# DEGAUSABSIMAX will NOT be updated.
#
# 3. If the requested current is less than 85% of
# DEGAUSABSIMAX or the polarity of the requested
# current has changed, then a degauss would be done
# automatically, which will take about 100 seconds.
# The current would then be set to the desired value,
# which would update Imax and the polarity setting if
# it has changed. During the degauss cycle, there
# should be some sort of indicator in EPICs that
# this is occurring, and perhaps an option provided to abort it.
#
record(calc, "XCOR:DOG:408:DEGAUS_ABSIMAX") {
  field(DESC, "Absolute Max. Degauss I")
  field(CALC, "ABS(A)")
  field(INPA, "XCOR:DOG:408:DEGAUS_IMAX")
  field(PREC, "6")
  field(EGU,  "Amps")
  field(HOPR, "1")
  field(LOPR, "-1")
  info(autosaveFields,"VAL RVAL")
}

# IACT Polarity
record(calcout, "XCOR:DOG:408:IACTPOL_CHECK") {
  field(DESC, "Determine IACT polarity")
  field(SCAN, "5 second")
  field(CALC, "ABS(A-B)>C?(A>=0?0:1):D")
  field(INPA, "XCOR:DOG:408:IACT")
  field(INPB, "XCOR:DOG:408:IACTPOL_CHECK.LA")
  field(INPC, "0.0001")
  field(INPD, "XCOR:DOG:408:IACTPOL_CHECK.PVAL")
  field(OOPT, "On Change")
  field(FLNK, "XCOR:DOG:408:IACTPOL")
}
record(bo, "XCOR:DOG:408:IACTPOL") {
  field(DESC, "Polarity of IACT")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
  info(autosaveFields,"VAL RVAL")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND


# ==================== USED BY NON-CRYO MAGNETS ONLY ===================
#
# There are different magnet hw configurations 
# that must be considered, when determining
# when degauss is lost.
#
# Configruation type 1: ps reamin on after degaussing  - Cryo Quads and QSM1 (decomissioned)
# Configuration type 2: ps is turned off after degaussing  - BXHS, BXSS, BCXXL
#==============================================================================
#
# FOR CONFIGUATION TYPE 2: non-cryo quads
# ------------------------
# Case 1: When the b-field is set above a limit <device>:DEGAUSBLIMIT,
# degauss is lost.
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 2: When the main supply is turned on, degauss is lost. (Warning)
#
#  - set <device>:DEGAUSOK=NO           - degauss ok status
#  - set <device>:DEGAUSOK.ZSV=MINOR    - degauss ok severity warning
#  - set <device>:STATMSG.FVSV=MINOR    - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR    - summary status, "Turned Off" alarm
#
# Case 3: if the main (bulk) ps is turned off and magnet was degaussed
# successfully, then degauss is lost.
#
#  - set <device>:STATMSG.FVSV=MAJOR - summary status, "Not Degaus'd" alarm
#  - set <device>:STATMSG.FRSV=MAJOR - sumamry status, "Turned Off" alarm
#  - set <device>:DEGAUSOK.ZSV=MAJOR - degauss status NO severity
#  - set <device>:DEGAUSOK=NO        - degauss status
# 
record(calcout,"XCOR:DOG:408:DEGAUS_STATE_CHECK") {
  field(DESC, "Check Degauss lost")
  field(CALC, "D=3?0:A=0?1:B&&C?2:B&&(C=0)?3:(B+C)=0?4:0")
  field(INPA, "XCOR:DOG:408:DEGAUSENABLE CP")
  field(INPB, "XCOR:DOG:408:DEGAUSOK")
  field(INPC, "XCOR:DOG:408:STATE CP")
  field(INPD, "XCOR:DOG:408:STATE.SEVR")
  field(OUT,  "XCOR:DOG:408:DEGAUS_STATE_SEQ.SELN PP")
  field(ASG,  "Internal")
}
record(seq, "XCOR:DOG:408:DEGAUS_STATE_SEQ") {
  field(DESC, "Degauss State Sequence")
  field(SELM, "Specified")
  field(SELL, "XCOR:DOG:408:DEGAUS_STATE_CHECK")
  field(LNK1, "XCOR:DOG:408:DEGAUS_STATE_DISABLE.PROC PP")
  field(LNK2, "XCOR:DOG:408:DEGAUS_STATE_LOST.PROC PP")
  field(LNK3, "XCOR:DOG:408:DEGAUS_STATE_GOOD.PROC PP")
  field(LNK4, "XCOR:DOG:408:DEGAUS_STATE_OFF.PROC PP")
  field(ASG,  "Internal")
}


# If degauss disabled then 
#  - set the status summary message alarm severit to
#     - "Turned Off"   to MAJOR
#     - "Not Degaus'd" to MINOR
#  - set DEGUASOK=NO 
#  - set DEGAUSOK.ZSV=NO_ALARM
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# for the main, instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
# 
record(seq, "XCOR:DOG:408:DEGAUS_STATE_DISABLE") {
  field(DESC, "Degauss not used")
  field(LNK1, "XCOR:DOG:408:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:DOG:408:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "2")
  field(DOL4, "1")
  field(DOL5, "2")
  field(LNK3, "XCOR:DOG:408:STATMSG.FRSV")
  field(LNK4, "XCOR:DOG:408:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}


# If degauss is enabled, and the magnet was degaussed successfully 
# and the ps state was turned on(1), then degauss
# has been lost. 
#
#  - set the status summary messages alarm severity for
#     -	"Turned Off"    to MINOR
#     - "Not Degaus'd"  to MINOR
#  - set DEGAUSLOSTOD, this is done in sequence mgntCtrl.st
#  - set DEGAUSOK=NO 
#  - set DEGAUSOK.ZSV=MINOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:DOG:408:DEGAUS_STATE_LOST") {
  field(DESC, "Degauss lost and ps On")
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:408:DEGAUSOK.ZSV")
  field(LNK2, "XCOR:DOG:408:DEGAUSOK PP")

# Set status summary msg "Turned Off"   severity to MINOR
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(LNK3, "XCOR:DOG:408:STATMSG.FRSV")
  field(LNK4, "XCOR:DOG:408:STATMSG.FVSV PP")
  field(LNK5, "")
  field(ASG,  "Internal")
}

# If degauss is enabled, the magnet is not degaussed,
# and the ps state is 0(off), then:
#
#  - set the status summary message alarm severity 
#      - "Turned Off"   to  MAJOR
#      - "Not Degaus'd" to  MAJOR
#  - set DEGAUSOK.ZSV=MAJOR
#
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MAJOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be created in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8.
#
record(seq, "XCOR:DOG:408:DEGAUS_STATE_OFF") {
  field(DESC, "Degaused lost and ps Off")
  field(DOL1, "2")
  field(LNK1, "XCOR:DOG:408:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to MAJOR
# Set status summary msg "Not Degaus'd" severity to MAJOR
  field(DOL2, "2")
  field(DOL3, "2")
  field(DOL4, "2")
  field(LNK2, "XCOR:DOG:408:STATMSG.FRSV")
  field(LNK3, "XCOR:DOG:408:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

# Degauss is enabled, the magent was degaussed successfully,
# and the ps state is 0 (off), then:
#
# Case 1: for non-cryo magnets(0x1e/30 dec)
#  - set the status summary message alarm severity
#      -  "Turned Off"   to to NO_ALARM
#      -  "Not Degaus'd" to to MINOR
#  - set the DEGAUSOK.ZSV=MINOR
#
# Note: This LNK macro is no longer needed, so use default of blank.
# If this is the string main then also,
#  - set slaves status summary message "Turned Off" severity to MINOR
#  LNK=DEGAUSSLAVESGO.DOL PP
#
# The pv DEGAUSSLAVESGO must be crated in the database substitutions file
# that defines the main, by instantianting mgnt_string_ctrl.template 
# specifying the string slaves in CH1-8..
#
# Case 2: for cryo magnets (1)
#  - set the status summary message alarm severity for:
#       "Not Degaus'd" to to MINOR
#
record(seq, "XCOR:DOG:408:DEGAUS_STATE_GOOD") {
  field(DESC, "Degauss good")
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:408:DEGAUSOK.ZSV PP")

# Set status summary msg "Turned Off"   severity to NO_ALARM
# Set status summary msg "Not Degaus'd" severity to MINOR
  field(DOL3, "1")
  field(LNK2, "XCOR:DOG:408:STATMSG.FRSV PP")
  field(LNK3, "XCOR:DOG:408:STATMSG.FVSV PP")
  field(LNK4, "")
  field(ASG,  "Internal")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(mbbo, "XCOR:DOG:408:FUNC") {
  field(DESC, "XCOR:DOG:408 Function")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "NO")

# Control functions
# Note: SLIDING and FEEDBACK are obsolete
  field(ZRST, "READY")
  field(ONST, "SLIDING")
  field(TWST, "TRIM")
  field(THST, "CALIB")
  field(FRST, "STDZ")
  field(FVST, "DEGAUSS")
  field(SXST, "PERTURB")
  field(SVST, "DAC_ZERO")
  field(EIST, "RESET")
  field(NIST, "TURN_ON")
  field(TEST, "TURN_OFF")
  field(ELST, "SAVE_BDES")
  field(TVST, "LOAD_BDES")
  field(TTST, "UNDO_BDES)")
  field(FTST, "BACT_TO_BDES")
  field(FFST, "BCON_TO_BDES")
#
# Number representation for control function
  field(ZRVL, "0")
  field(ONVL, "0")
  field(TWVL, "1")
  field(THVL, "9")
  field(FRVL, "10")
  field(FVVL, "0")
  field(SXVL, "2")
  field(SVVL, "8")
  field(EIVL, "11")
  field(NIVL, "0")
  field(TEVL, "0")
  field(ELVL, "5")
  field(TVVL, "6")
  field(TTVL, "7")
  field(FTVL, "4")
  field(FFVL, "3")
  field(OUT, "XCOR:DOG:408:CTRL CA")
}

# <DEV>:CTRL pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:DOG:408:CTRL") {
  field(DESC, "XCOR:DOG:408 Control")
  field(PINI, "NO")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "CALIB")
  field(TEST, "STDZ")
  field(ELST, "RESET")
  field(TVST, "")
  field(TTST, "")
  field(FTST, "")
  field(FFST, "")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "3")
  field(TEVL, "4")
  field(ELVL, "8")
  field(TVVL, "0")
  field(TTVL, "0")
  field(FTVL, "0")
  field(FFVL, "0")
  field(OUT, "XCOR:DOG:408:SELECTEN.A PP")
  field(SDIS, "0")
}

# If a function has been selected set this unit to busy
record(calcout, "XCOR:DOG:408:SELECTEN") {
  field(DESC, "Control Select Enable")
  field(CALC, "A>0?1:A")
  field(FLNK, "XCOR:DOG:408:BUSY")
}

# Set to FREE on IOC reboot
record(bo, "XCOR:DOG:408:BUSY") {
  field(DESC, "XCOR:DOG:408 Ctrl Done")
  field(DOL, "XCOR:DOG:408:SELECTEN")
  field(ZNAM, "FREE")
  field(ONAM, "BUSY")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:408:SELECT")
}

record(bo, "XCOR:DOG:408:SELECT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR") 
}

record(bo, "XCOR:DOG:408:ABORT") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
}

# <DEV>:CTRLSTATE pv is processed at boot in the
# sequence mgntCtrl.st Processed in sequence
#
record(mbbo, "XCOR:DOG:408:CTRLSTATE") {
  field(DESC, "XCOR:DOG:408 Ctrl Status")
  field(ZRST, "Done")
  field(ONST, "Ramping")
  field(TWST, "Ramp Wait")
  field(THST, "Mini-stdz")
  field(FRST, "Unavailable")
  field(FVST, "Ramp Timeout")
  field(SXST, "Error")
  field(SVST, "Timeout")
  field(EIST, "Abort")
  field(NIST, "Disabled")
  field(TEST, "Feedback")
  field(ELST, "Settling")
  field(TVST, "Chg Polarity")
  field(TTST, "Tripped")
  field(FTST, "Turn Off wait")
  field(FFST, "Turn On wait")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.1)
#! Record("XCOR:DOG:408:CTRL",20,20,0,0,"XCOR:DOG:408:CTRL")
#! Field("XCOR:DOG:408:CTRL.OUT",16777215,1,"XCOR:DOG:408:CTRL.OUT")
#! Link("XCOR:DOG:408:CTRL.OUT","XCOR:DOG:408:SELECTEN.A")
#! Field("XCOR:DOG:408:CTRL.VAL",16777215,1,"XCOR:DOG:408:CTRL.VAL")
#! Record("XCOR:DOG:408:SELECTEN",321,381,0,0,"XCOR:DOG:408:SELECTEN")
#! Field("XCOR:DOG:408:SELECTEN.A",16777215,0,"XCOR:DOG:408:SELECTEN.A")
#! Field("XCOR:DOG:408:SELECTEN.FLNK",16777215,1,"XCOR:DOG:408:SELECTEN.FLNK")
#! Link("XCOR:DOG:408:SELECTEN.FLNK","XCOR:DOG:408:BUSY")
#! Field("XCOR:DOG:408:SELECTEN.VAL",16777215,1,"XCOR:DOG:408:SELECTEN.VAL")
#! Record("XCOR:DOG:408:BUSY",623,274,0,0,"XCOR:DOG:408:BUSY")
#! Field("XCOR:DOG:408:BUSY.DOL",16777215,0,"XCOR:DOG:408:BUSY.DOL")
#! Link("XCOR:DOG:408:BUSY.DOL","XCOR:DOG:408:SELECTEN.VAL")
#! Field("XCOR:DOG:408:BUSY.FLNK",16777215,1,"XCOR:DOG:408:BUSY.FLNK")
#! Link("XCOR:DOG:408:BUSY.FLNK","XCOR:DOG:408:SELECT")
#! Record("XCOR:DOG:408:SELECT",669,508,0,1,"XCOR:DOG:408:SELECT")
#! Record("XCOR:DOG:408:FUNC",940,120,0,0,"XCOR:DOG:408:FUNC")
#! Field("XCOR:DOG:408:FUNC.OUT",16777215,0,"XCOR:DOG:408:FUNC.OUT")
#! Link("XCOR:DOG:408:FUNC.OUT","XCOR:DOG:408:CTRL.VAL")
#! Record("XCOR:DOG:408:ABORT",193,41,0,0,"XCOR:DOG:408:ABORT")
#! Record("XCOR:DOG:408:CTRLSTATE",369,34,0,0,"XCOR:DOG:408:CTRLSTATE")
#! TextBox(TB0,563,0,946,210,0,"Dialog",12,1,16777215,"Macros:\nDEV =PRIM:LOCA:UNIT\nSETL = Settling time before limit checking is reinstated\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nMENU*= Name of ctrl menu item\nCALC=equation for associating menu item with its seq record; if no seq record, then associate with SNL\nINPA = 0 if no feedback for this magnet; $DEV:FBCKCTRL otherwise\nFIND=index of Feedback in CTRL menu",null)
#! TextBox(TB8,3100,3340,3440,3460,0,"Dialog",12,1,16777215,"",null)
#! TextBox(TB6,1104,136,1595,350,0,"Dialog",12,1,16777215,"HLApps, slc-aware code sets the mgnt function via FUNC.\nFUNC contains the hard-coded indices for every possible function.\nCTRL contains only those functions available for the device, and thus may have different indices device to device. The macros in FUNC map hard-coded function values used by clients other than EDM to the unique CTRL indices per device",null)
#! TextBox(TB2,506,736,926,856,0,"Dialog",12,1,16777215,"XCOR:DOG:408:SELECT is used for Multi-device selection.\nIt is enabled when associated XCOR:DOG:408:CTRL is \"0\" (DONE).\nIt is disabled when associated XCOR:DOG:408:CTRL other than DONE.\nWhen enabled, user can choose to include in a list.\nWhen a \"list\" command is issued, SNL sequences know to \ninclude this unit.",null)
#! TextBox(TB18,2260,3400,2260,3400,0,"Dialog",12,1,16777215,"HOOK CTRLUNDOBDES UP TO\n \nWhen done testing SNL PERTURB!!",null)
#! TextBox(TB1,12,681,392,921,0,"Dialog",12,1,16777215,"XCOR:DOG:408:CTRL:\n  Set by users to perform a series of steps.\n  Only this IOC is allowed to set CTRL back to DONE after\n  action is complete.  CA security must be set to prevent\n  users outside this IOC from changing CTRL if it is not \n  in the DONE state.\n\n  For complicated actions such as TRIM, CALIBRATE, and \n  STANDARDIZE, a sequence running on this IOC will \n  perform the action and reset CTRL.\n\n  When a device is controlled by fast feedback, CTRL \n  remains in the Feedback status state until the device is removed from fast feedback control.  \n  ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(calcout, "XCOR:DOG:408:BCTRL_INIT") {
  field(DESC, "Process BCTRL on boot")
  field(PINI, "YES")
  field(CALC, "A=3?1:0")
  field(INPA, "XCOR:DOG:408:BCTRL.SEVR")
  field(OUT,  "XCOR:DOG:408:BCTRL.PROC PP")
  field(OOPT, "Transition To Non-zero")
}

# Note: for a string slave set the ACT
# macro to the following:
#  ACT=<dev>:IACTCALC MS
record(sub, "XCOR:DOG:408:BACT") {
  field(DESC, "Actual B")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:DOG:408:BACT")
  field(INPB, "XCOR:DOG:408:POLYCOEF")
  field(INPC, "XCOR:DOG:408:POLYCOEF.A")
  field(INPD, "XCOR:DOG:408:POLYCOEF.B")
  field(INPE, "XCOR:DOG:408:IACT MS")
  field(INPF, "XCOR:DOG:408:BDELTAS PP")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(HIHI, "0.01049318")
  field(LOLO, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.01049318")
  field(LOW,  "-0.01049318")
  field(FLNK, "XCOR:DOG:408:BACTFO")
  info(autosaveFields,"HYST")
}

# Outputs:
#  I = HIGH warning delta for ACT
#  J = LOW  alarm delta for ACT
#  K = HIHI warning delta for MON
#  L = LOLO monitor alarm for MON
#  M = Out of trim tolerance flag if set to 1
#  N = MPS Alarm delta
#  F = Multiple of ACT deltas used for MON deltas
#      this should be set to 0 for ps that don't have
#      an auxillary adc.
#
record(sSub, "XCOR:DOG:408:BDELTAS") {
  field(DESC, "ACT and MON Deltas")
  field(INAM, "mgntInit")
  field(SNAM, "mgntPhyDeltas")
  field(EGU,  "kG-m")
  field(HOPR, "1")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(INPA, "XCOR:DOG:408:BDES")
  field(INPB, "XCOR:DOG:408:TRIMBTOL")
  field(INPC, "XCOR:DOG:408:TRIMBTOLR")
  field(INPD, "XCOR:DOG:408:CHCKBTOL")
  field(INPE, "XCOR:DOG:408:CHCKBTOLR")
  field(F,    "2.0")
  field(INPG, "30")
  field(INPH, "XCOR:DOG:408:BACT.VAL")
#
# MPS absolute and relative tolerances
  field(INPP, "XCOR:DOG:408:MPSBTOL")
  field(INPQ, "XCOR:DOG:408:MPSBTOLR")
  field(FLNK, "XCOR:DOG:408:BCONLIMITS")
  info(autosaveFields,"F")
}

# This record is processed by BDELTAS
record(aSub, "XCOR:DOG:408:BCONLIMITS") {
  field(DESC, "Config B-field Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntBCONLimits")
  field(INPA, "XCOR:DOG:408:BDES")
  field(INPB, "XCOR:DOG:408:BDELTAS.I")
  field(INPG, "XCOR:DOG:408:DEBUG.RVAL")
  field(FTA,  "DOUBLE")
  field(FTB,  "DOUBLE")
  field(FTG,  "ULONG")
  field(OUTA, "XCOR:DOG:408:BCON.HIGH")
  field(OUTB, "XCOR:DOG:408:BCON.LOW")
  field(OUTC, "XCOR:DOG:408:BCON.HIHI")
  field(OUTD, "XCOR:DOG:408:BCON.LOLO PP")
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:408:IDELTAS")
}


# The following PV is processed by <dev>:BACT
# which is processed by <dev>:BACT
#
record(fanout, "XCOR:DOG:408:BACTFO") {
  field(DESC, "BACT processing")
  field(SELM, "All")
  field(LNK1, "XCOR:DOG:408:BDIFF")
  field(LNK2, "XCOR:DOG:408:BADIFF")
  field(LNK3, "XCOR:DOG:408:BRATIO")
  field(LNK4, "XCOR:DOG:408:MPSLIMITS")
  field(LNK5, "XCOR:DOG:408:I2BSTATUS")
  field(LNK6, "XCOR:DOG:408:IACTFO.PROC")
}

record(calc, "XCOR:DOG:408:BDIFF") {
  field(DESC, "BDES-BACT")
  field(CALC, "A-B")
  field(INPA, "XCOR:DOG:408:BDES")
  field(INPB, "XCOR:DOG:408:BACT")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(calc, "XCOR:DOG:408:BADIFF") {
  field(DESC, "Absolute BDES-BACT")
  field(INPA, "XCOR:DOG:408:BDIFF")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(CALC, "A<0?ABS(A):A")
}

record(calc, "XCOR:DOG:408:BRATIO") {
  field(DESC, "BACT Error")
  field(CALC, "B?A/B:0")
  field(INPA, "XCOR:DOG:408:BDIFF")
  field(INPB, "XCOR:DOG:408:BDES.HOPR")
  field(EGU, "kG-m")
  field(PREC, "7")
}

record(mbbi, "XCOR:DOG:408:I2BSTATUS") {
  field(DESC, "Poly Convergence Status")
  field(NOBT, "16")
  field(ZRST, "Converged")
  field(ONST, "Almost Conv")
  field(TWST, "No Conv")
  field(THST, "Zero Slope")
  field(FRST, "Poly Error")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "MAJOR")
  field(FRSV, "MAJOR")
  field(INP, "XCOR:DOG:408:BACT.J")
}


# Note: for a string slave set the MONFL
# macro to the following:
#  MONFL=<dev>:IMONCALC MS
record(sub, "XCOR:DOG:408:BMON") {
  field(DESC, "Second Transductor")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntReversePoly")
  field(INPA, "XCOR:DOG:408:BMON")
  field(INPB, "XCOR:DOG:408:POLYCOEF")
  field(INPC, "XCOR:DOG:408:POLYCOEF.A")
  field(INPD, "XCOR:DOG:408:POLYCOEF.B")
  field(INPE, "XCOR:DOG:408:IMON MS")
  field(INPF, "XCOR:DOG:408:BDELTAS.VAL")
  field(INPG, "100")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(HIHI, "0.01049318")
  field(LOLO, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")
  field(LLSV, "MAJOR")
  field(HIGH, "0.01049318")
  field(LOW,  "-0.01049318")
}

# for indivdual magnets and string main use the
# default macors. For slaves set the macros
# as follows for slaves w/o trim coils:
#  OMSL=closed_loop
#  DOL=MCOR:EXT:216:BDES CP
record(ao,  "XCOR:DOG:408:BDES") {
   field(DESC, "Desired B-Field")
   field(PINI, "YES")
   field(DRVH, "0.01049318")
   field(DRVL, "-0.01049318")
   field(HOPR, "0.01049318")
   field(LOPR, "-0.01049318")
   field(PREC, "7")
   field(EGU,  "kG-m")
   field(MDEL, "-1")
   field(OMSL, "supervisory")
#   field(DOL,  "")
   field(OUT,  "XCOR:DOG:408:B2IDES PP")
   info(autosaveFields,"VAL")
}
record(sub, "XCOR:DOG:408:B2IDES") {
  field(DESC, "Convert Desired B-Field to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:408:POLYCOEF")
  field(INPC, "XCOR:DOG:408:POLYCOEF.A")
  field(INPD, "XCOR:DOG:408:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(MDEL, "-1")
  field(INPE, "XCOR:DOG:408:BDES.DRVH")
  field(INPF, "XCOR:DOG:408:BDES.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:408:IDES")
}
record(sub, "XCOR:DOG:408:BNOM") {
  field(DESC, "Nominal Field")
  field(PINI, "YES")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:408:POLYCOEF")
  field(INPC, "XCOR:DOG:408:POLYCOEF.A")
  field(INPD, "XCOR:DOG:408:POLYCOEF.B")
  field(INPE, "XCOR:DOG:408:BDES.DRVH")
  field(INPF, "XCOR:DOG:408:BDES.DRVL")
  field(EGU, "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(VAL, "0.0")
  field(FLNK, "XCOR:DOG:408:INOM")
}

record(sub, "XCOR:DOG:408:BACTLIMITS") {
  field(DESC, "ACT Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:408:BDES.VAL")
  field(INPB, "XCOR:DOG:408:BDES.DRVH")
  field(INPC, "XCOR:DOG:408:BDES.DRVL")
  field(INPD, "XCOR:DOG:408:BDELTAS.I")
  field(INPE, "XCOR:DOG:408:BDELTAS.J")
  field(INPG, "XCOR:DOG:408:STATE")
  field(INPH, "XCOR:DOG:408:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(sub, "XCOR:DOG:408:BMONLIMITS") {
  field(DESC, "MON Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntLimits")
  field(INPA, "XCOR:DOG:408:BDES.VAL")
  field(INPB, "XCOR:DOG:408:BDES.DRVH")
  field(INPC, "XCOR:DOG:408:BDES.DRVL")
  field(INPD, "XCOR:DOG:408:BDELTAS.K")
  field(INPE, "XCOR:DOG:408:BDELTAS.L")
  field(INPG, "XCOR:DOG:408:STATE")
  field(INPH, "XCOR:DOG:408:HSTA")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(BRSV, "INVALID")
}

record(seq, "XCOR:DOG:408:BLIMITS") {
  field(DESC, "ACT Limits")
  field(PREC, "7")
  field(DOL1, "XCOR:DOG:408:BLIMITS")
  field(LNK1, "XCOR:DOG:408:BACTLIMITS.F PP")
  field(DOL2, "XCOR:DOG:408:BACTLIMITS.I")
  field(LNK2, "XCOR:DOG:408:BACT.HIGH")
  field(DOL3, "XCOR:DOG:408:BACTLIMITS.J")
  field(LNK3, "XCOR:DOG:408:BACT.LOW")
  field(DOL4, "XCOR:DOG:408:BACTLIMITS.K")
  field(LNK4, "XCOR:DOG:408:BACT.HIHI")
  field(DOL5, "XCOR:DOG:408:BACTLIMITS.L")
  field(LNK5, "XCOR:DOG:408:BACT.LOLO")
  field(DOL6, "XCOR:DOG:408:BLIMITS")
  field(LNK6, "XCOR:DOG:408:BMONLIMITS.F PP")
  field(DOL7, "XCOR:DOG:408:BMONLIMITS.I")
  field(LNK7, "XCOR:DOG:408:BMON.HIGH")
  field(DOL8, "XCOR:DOG:408:BMONLIMITS.J")
  field(LNK8, "XCOR:DOG:408:BMON.LOW")
  field(DOL9, "XCOR:DOG:408:BMONLIMITS.K")
  field(LNK9, "XCOR:DOG:408:BMON.HIHI")
  field(DOLA, "XCOR:DOG:408:BMONLIMITS.L")
  field(LNKA, "XCOR:DOG:408:BMON.LOLO")
  field(FLNK, "XCOR:DOG:408:ILIMITS")
  field(SCAN, "5 second")
}

record(ao, "XCOR:DOG:408:BCTRL") {
  field(DESC, "B-Perturb")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
# The omsl field is set to open/closed loop
# by the sequence mgntCtrl.st to dispable the
# user from using the slider.
#
  field(MDEL, "-1")
  field(FLNK, "XCOR:DOG:408:BCTRLGO")
  info(autosaveFields,"VAL")
}

# Process IDIRECT upon a new IDES but prior to setting ISETPT
# insert delay to give IDES a chance to update
# Process IDIRECT directly instead of waiting for the
# 0.5 sec process scan in the readback V to I to B chain.
# When CHECKSTDZLOST is processed, IDIRECT will have processed
# Then go on to act upon BCTRL by processing BCTRLSUB
#
record(seq, "XCOR:DOG:408:BCTRLGO") {
  field(DESC, "Update DES and perturb")
  field(PREC, "7")

# Disable BACT limits
  field(DOL1, "1")
  field(LNK1, "XCOR:DOG:408:BLIMITS.VAL")

# Update BDES with the BCTRL (slider) value
  field(DOL2, "XCOR:DOG:408:BCTRL.VAL")
  field(LNK2, "XCOR:DOG:408:BDES PP")

  field(DOL3, "1")
  field(LNK3, "XCOR:DOG:408:IDIRECT.PROC PP")

  field(DOL4, "1")
  field(LNK4, "XCOR:DOG:408:CHECKSTDZLOST.PROC PP")

  field(DOL5, "XCOR:DOG:408:BCTRL.VAL")
  field(LNK5, "XCOR:DOG:408:BCTRLSUB PP")

# Re-enable BACT limits
  field(DOL6, "0")
  field(LNK6, "XCOR:DOG:408:BLIMITS.VAL")
}

# Convert B-field to Current and output to ISETPT
record(sub, "XCOR:DOG:408:BCTRLSUB") {
  field(DESC, "Feedback")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:408:POLYCOEF")
  field(INPC, "XCOR:DOG:408:POLYCOEF.A")
  field(INPD, "XCOR:DOG:408:POLYCOEF.B")
  field(INPE, "XCOR:DOG:408:BDES.DRVH")
  field(INPF, "XCOR:DOG:408:BDES.DRVL")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(MDEL, "-1")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:408:ISETPT")
}

record(ao, "XCOR:DOG:408:BDESPREVTRIM") {
  field(DESC, "trim bdes for undo")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(PINI, "YES")
  info(autosaveFields,"VAL")
}

record(stringin, "XCOR:DOG:408:MADNAME") {
  field(DESC, "MAD deck nomenclature")
  field(PINI, "YES")
  field(VAL, "XCL5P")
}

record(ai, "XCOR:DOG:408:Z") {
  field(DESC, "Z-Position")
  field(DTYP, "Soft Channel")
  field(EGU, "m")
  field(HOPR, "100000.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(PINI, "YES")
  field(VAL, "849.267333")
}

record(ao, "XCOR:DOG:408:BMAX") {
  field(DESC, "Max B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU, "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "0.01049318")
  field(FLNK, "XCOR:DOG:408:BSTEP")
}

record(ao, "XCOR:DOG:408:BMIN") {
  field(DESC, "Min B-Field")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU, "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PREC, "7")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(FLNK, "XCOR:DOG:408:BSTEP")
}

record(ao, "XCOR:DOG:408:BDESSAVE") {
  field(DESC, "bdes for save/load")
  field(DTYP, "Soft Channel")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(PINI, "YES")
  field(PREC, "7")
}

# This record is processed by XCOR:DOG:408:BCONLIMITS
# For slaves w/o trims this value is calcuated from the icon of the main
# then passed backwards through the IVB poly.
# For slave w/ trims this value is calcated from the icon of the main plus
# the bcon if the trim, passed backwareds thought the IVB poly
# For individual magnets or a main this value is entered.
record(ao, "XCOR:DOG:408:BCON") {
  field(DESC, "Config B-Field ")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
# Set MINOR Alarm as the default, slaves will set NO_ALARM=0.
  field(HHSV, "MINOR")
  field(LLSV, "MINOR")
  field(HSV,  "MINOR")
  field(LSV,  "MINOR")

#  field(DOL , "")
  field(OMSL, "supervisory")
  field(OUT,  "XCOR:DOG:408:B2ICON PP")
  info(autosaveFields,"VAL")
}

record(sub, "XCOR:DOG:408:B2ICON") {
  field(DESC, "Convert Desired ICon to Curr")
  field(ASG,  "Internal")
  field(INAM, "mgntInitPoly")
  field(SNAM, "mgntPoly")
  field(INPB, "XCOR:DOG:408:POLYCOEF")
  field(INPC, "XCOR:DOG:408:POLYCOEF.A")
  field(INPD, "XCOR:DOG:408:POLYCOEF.B")
  field(PREC, "7")
  field(EGU,  "kG-m")
  field(HOPR, "0.01049318")
  field(LOPR, "-0.01049318")
  field(MDEL, "-1")
  field(INPE, "XCOR:DOG:408:BCON.DRVH")
  field(INPF, "XCOR:DOG:408:BCON.DRVL")
  field(BRSV, "INVALID")
  field(FLNK, "XCOR:DOG:408:ICON")
}

# This pv calculates the step size for the BCTRL slider.
# Currently, EDM does not allow for a PV to be used for the
# step size, so these values must be entered manaully for
# each slider for a device.
# AL 11/2023 - Allow custom step size factor
record(calc, "XCOR:DOG:408:BSTEP") {
  field(DESC, "B-Field step size")
  field(CALC, "(C==3)||(D==3)?0:ABS(A-B)*0.005")
  field(INPA, "XCOR:DOG:408:BMAX")
  field(INPB, "XCOR:DOG:408:BMIN")
  field(INPC, "XCOR:DOG:408:BMIN.SEVR")
  field(INPD, "XCOR:DOG:408:BMAX.SEVR")
  field(EGU, "kG-m")
  field(PINI, "YES")
  field(PREC, "7")
}

# These PVs enable or disable the BCTRL slider depending
# on whether the magnet is online or not
record(calcout,"XCOR:DOG:408:BCTRLDISABLECALC")
{
  field(DESC, "Calc for disabling BCTRL")
  field(ASG,  "Internal")
  field(CALC, "A?2:1")
  field(INPA, "XCOR:DOG:408:ONLINE CP")
  field(OUT,  "XCOR:DOG:408:BCTRLDISABLEFOUT PP")
}

record(fanout, "XCOR:DOG:408:BCTRLDISABLEFOUT")
{
  field(DESC, "Disable BCTRL fanout")
  field(SELM, "Specified")
  field(SELL, "XCOR:DOG:408:BCTRLDISABLECALC")
  field(LNK1, "XCOR:DOG:408:BCTRLDISABLE")
  field(LNK2, "XCOR:DOG:408:BCTRLENABLE")
}

record(stringout, "XCOR:DOG:408:BCTRLDISABLE")
{
  field(DESC, "Disable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:DOG:408:BCTRL.ASG")
  field(VAL,  "NOWRITE")
  field(FLNK, "XCOR:DOG:408:BCTRLDISV_UPDATE")
}

record(stringout, "XCOR:DOG:408:BCTRLENABLE")
{
  field(DESC, "Enable BCTRL")
  field(DTYP, "Soft Channel")
  field(OUT,  "XCOR:DOG:408:BCTRL.ASG")
  field(VAL,  "")
  field(FLNK, "XCOR:DOG:408:BCTRLDISV_UPDATE")
}

record(calcout, "XCOR:DOG:408:BCTRLDISV_UPDATE")
{
  field(DESC, "Calc for updating BCTRL.DISV")
  field(ASG,  "Internal")
  field(CALC, "A")
  field(INPA, "XCOR:DOG:408:ONLINE")
  field(OUT,  "XCOR:DOG:408:BCTRL.DISV")
}




#! TextBox(TB4,340,2480,840,2980,0,"Dialog",12,1,16777215,"Macros:\nDEV = PRIM:LOCA:UNIT\nPHY = for magnets: B\n       = for phase and amplitude: P or A\nRAW = for magnets: I\n        = for phase and amplitude: V  \nEGU = Engineering Units \nDRVH, DRVL  =High and Low Drive Limits\n       NOTE: DRVH same as BMAX in the SLC database. \n                 For correctors (bipolar power supplies), DRVL=-DRVH\n                 For quads, bends, sexts, etc (unipolar power supplies), DRVL = 0.\nPREC = Precision (# after the decimal point)\nADEL = Readback Archive Delta Amount\n             Also used in the epsilon calculation and alarm limit calc.\n       NOTE: ADEL same as TOLS[3] in the SLC database.\nWDEL = Warning Delta Amount used in the warning limit calc.\n       NOTE: WDEL same as TOLS[1] in the SLC database.\nMDEL = Readback Monitor Delta Amount\nHYST = Readback Alarm Hysterisis\nMAD = MAD Deck Name\nAFRAC = Fraction of DES for epsilon calculation and alarm limit calc.\n       NOTE: AFRAC same as TOLS[4] in the SLC database.\nWFRAC = Fraction of DES for warning limit calc.\n       NOTE: WFRAC same as TOLS[2] in the SLC database.\nMFRAC = Fraction of ACT deltas for MON deltas\n       NOTE: MFRAC same as TOLF in the SLC database.\nPIND = PERTURB menu index; rval gets set to 6 from this index\n\n",null)
#! TextBox(TB3,340,3860,980,3900,0,"Dialog",18,1,16777215,"Controlled Devices - Physical Engineering Units Records",null)
#! TextBox(TB2,4340,1980,4760,2420,0,"Dialog",12,1,16777215,"XCOR:DOG:408:BACT and MON\n  are processed via links from \n  XCOR:DOG:408:IACT (device raw value readback 1)\n  and\n  XCOR:DOG:408:IMON (device raw value readback 2)\nThey back-calculate the physical readback value from\nraw readback value (\"reverse polynomial\").  Input:\nVAL = Initial guess for back calculation\nA = Not Used\nB = Number of polynomial coeffs from XCOR:DOG:408:POLYCOEF\nC = First polynomial coefficient (offset if linear)\nD = Second polynomial coefficient (slope if linear)\nE = XCOR:DOG:408:IACT or MON\nF = Epsilon to use in back-calculation\nG = # of interations to use in back-calculation\nDPVT = Pointer to polynomial coeff (set by mgntInitPoly)\n\nOuput:\nH = Previous guess\nI = Number of iterations\nJ = Convergence status\nK = Raw value corresponding to VAL\nL = Slope where converged \nVAL = Best Estimate Physical Value ",null)
#! TextBox(TB1,1846,2087,2126,2327,0,"Dialog",12,1,16777215,"XCOR:DOG:408:BDES\n  is processed when set by CA users or \n  XCOR:DOG:408:BCTRL (which is set by high\n  level apps to set DES and perturb).  It forces \n  processing of IDES.  When fast \n  feedback is on, this record is \n  periodically updated and uses the value \n  from the feedback controller received over the fcom network.\n\nNOTE: Setting DES does NOT update the\nhardware.  This requires a second \ncommand to TRIM or PERTURB.",null)
#! TextBox(TB0,2120,1960,2320,2080,0,"Dialog",12,1,16777215,"Keep the last BDES value that was trimmed for the undo command. Trim SNL will process",null)
#! TextBox(TB10,1680,3380,2020,3500,0,"Dialog",12,1,16777215,"BCON\nTurns yellow (MINOR alarm) if it doesn't match BDES exactly.\nVAL = BCON\nINPA = BDES\nsub mgntBCONLimits sets HIGH, LOW, HIHI,LOLO\nto BDES",null)
#! TextBox(TB9,1700,2540,1980,2660,0,"Dialog",12,1,16777215,"XCOR:DOG:408:BFBCK\n  is processed by fast feedback only when \n  fast feedback is on.  It is disabled when\n  feedback is off.  It forces processing of\n  XCOR:DOG:408:ISETPT which gets its \n  input from the K field of this record when\n  fast feedback is on.\n",null)
#! TextBox(TB8,2040,2720,2320,3080,0,"Dialog",12,1,16777215,"  These subroutine records convert a \n  desired physical unit value to raw units \n  using linear or polynomial conversion.\n      Input:\n  VAL = Desired value in physical units.\n  B = Number of polynomial coefficients \n        (XCOR:DOG:408:POLYCOEF)\n  C = First coefficient (offset if linear)\n  D = Second coefficient (slope if linear)\n  E = High Drive Limit\n  F = Low  Drive Limit\n  G = Fast feedback desired value\n  H = Fast feedback disable (0), enable (1)\n  DPVT = Pointer to polynomial coefficients \n               set by mgntInitPoly \n      Output:\n  K = Desired Raw Value (polynomial(VAL)) \n  L = Slope of the polynomial at this value\n",null)
#! TextBox(TB7,2760,580,3080,720,0,"Dialog",12,1,16777215,"XCOR:DOG:408:B*LIMITS and XCOR:DOG:408:BLIMITS:\n  Calculate alarm and warning limits based on \n  deltas from XCOR:DOG:408:BDELTAS and the DES \n  value. Limits can be \"disabled\" (or set to drive \n  limits) on several conditions (the device is off, \n  setpoint is changing, deltas cannot be \n  calculated due to bad inputs).\n ",null)
#! TextBox(TB6,1326,1996,1814,2145,0,"Dialog",12,1,16777215,"XCOR:DOG:408:BCTRL and CTRLGO:\nCTRL is set by high level apps to update DES and perturb.  CTRL forces processing of CTRLGO and, if enabled, CTRLGO copies CTRL to DES and asks device control do a PERTURB_SLIDE. \nWhen feedback is ON, CTRLGO is disabled and CTRL is periodically processed. \nWhen feedback os OFF, CTRL is updated to BDES upon PERTURB, TRIM, etc\n   (first set BCTRL to closed_loop, then back to supervisory)\nWhen any function is active, disable CTRLGO",null)
#! TextBox(TB5,2500,3040,2840,3200,0,"Dialog",12,1,16777215,"XCOR:DOG:408:BDELTAS:\n  VAL = Difference used in reverse polynomial \n             calculation for BACT and MON\n  I      = ACT Warning Delta (slc TOLMX)\n  J      = ACT Alarm Delta\n  K     = MON Warning Delta\n  L     = MON Alarm Delta\n  M   = out of tolerance (=\"1\")\n ",null)
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(ai, "XCOR:DOG:408:MPSBTOLR") {
  field(DESC, "Relative mps tol")
  field(VAL, "2")
  field(PREC, "2")
  field(EGU, "%")
  field(HOPR, "10.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(calc, "XCOR:DOG:408:MPSBTOL") {
  field(DESC, "Absolute mps tol")
  field(EGU, "kG-m")
  field(PREC, "2")
  field(CALC, "ABS(A)*0.02")
  field(INPA, "XCOR:DOG:408:BMAX")
  field(PINI, "YES")
}

#
# 21-Aug-2013: K. Luchini  
# Set channel access security so that users
# cannot easily change values.
record(ao, "XCOR:DOG:408:MPSBMAX") {
  field(DESC, "MPS Max B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:408:MPSBMIN") {
  field(DESC, "MPS Min B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:408:MPSBLLIM") {
  field(DESC, "MPS Low Limit B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:408:MPSBLLIM2") {
  field(DESC, "MPS Low Limit #2 B-field")
  field(EGU, "kG-m")
  field(PREC, "7")
  field(DRVH, "0.01049318")
  field(DRVL, "-0.01049318")
  field(PINI, "YES")
  field(VAL, "-0.01049318")
  field(ASG, "EOICDESK")
  info(autosaveFields,"VAL")
}

# Set the default to Std
record(mbbo, "XCOR:DOG:408:MPSBITMASK") {
  field(DESC, "MPS Bitmask for tol check")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(TWVL, "4")
  field(THVL, "8")
  field(ZRST, "Std")
  field(ONST, "V1")
  field(TWST, "V2")
  field(THST, "V3")
  field(VAL,  "0")
  field(OUT,  "XCOR:DOG:408:MPSLIMITS.E PP")
}

record(aSub, "XCOR:DOG:408:MPSLIMITS") {
  field(DESC, "MPS alarm check")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMpsLimits")
#
# Inputs:
# 
#  A: Signals to monitor for MPS
#     0 - NONE, No MPS monitoring for this magnet
#     1 - PS ON 
#     2 - PS ON and BACT 
#  B: Difference  betweek BDES-BACT
#  C: Tolerance allowed (bact must be within this amount of bdes).
#  D: Actual field (BACT)
#  E: Bitmask of tolerance check algorithm
#         status: 1=ok 0=fault
#     bitNo
#     0   if (bdes-bact)<c) then  INTOL=true        else INTOL=false       (bact in-tol)
#     1   if (bact > f) then      INTOL_BMIN=true   else INTOL_BMIN=false  (only check if A=2)
#     2   if (g < bact > h) then  INTOL_BRANGE=true else INTOL_BRANGE=false
#     3   if (bact > i) then      INTOL_BMIN2=true  else INTOL_BMIN2=false  
#         Note: used to protect the undulator by preventing the huth stopper S2
#         form being pulled if the electron beam energy is below this limit.
#         BAS brings beam to S2 at that energy (2.2Gev) but SXR does not want to run
#         below 3.3Gev.  Email from RHI to Mboyes 10/16/2012 4:37pm.   
#
#  F: mps b-field lower limit  
#  G  mps b-field minimum
#  H: mps b-field maximum 
#  I: mps b-field lower limit #3 
#
  field(INPA, "XCOR:DOG:408:MPS.RVAL")
  field(INPB, "XCOR:DOG:408:BADIFF")
  field(INPC, "XCOR:DOG:408:BDELTAS.N")
  field(INPD, "XCOR:DOG:408:BACT")
  field(INPE, "XCOR:DOG:408:MPSBITMASK.RVAL")
  field(INPF, "XCOR:DOG:408:MPSBLLIM")
  field(INPG, "XCOR:DOG:408:MPSBMIN")
  field(INPH, "XCOR:DOG:408:MPSBMAX")
  field(INPI, "XCOR:DOG:408:MPSBLLIM2")
  field(FTA, "ULONG")
  field(FTB, "DOUBLE")
  field(FTC, "DOUBLE")
  field(FTD, "DOUBLE")
  field(FTE, "ULONG")
  field(FTF, "DOUBLE")
  field(FTG, "DOUBLE")
  field(FTH, "DOUBLE")
  field(FTI, "DOUBLE")
# Outputs:  indicate which mps tolerance check failed (binary 0/1)
# VALA = B-field within tol of (BDES-BACT)   (1=ok,0=fault) 
# VALB = B-field is greater than F           (1=ok,0=fault) 
# VALC = B-field is within G < bact > H =ok  (1=ok,0=fault)
# VALD = B-field is greater than I           (1=ok,0=fault)
  field(OUTA, "XCOR:DOG:408:INTOL.RVAL PP")
  field(OUTB, "XCOR:DOG:408:INTOL_BMIN.RVAL PP")
  field(OUTC, "XCOR:DOG:408:INTOL_BRANGE.RVAL PP")
  field(OUTD, "XCOR:DOG:408:INTOL_BMIN2.RVAL PP")
  field(FTVA, "ULONG")
  field(FTVB, "ULONG")
  field(FTVC, "ULONG")
  field(FTVD, "ULONG")
  field(BRSV, "INVALID")
  field(ASG, "NOWRITE")
}

############ Start MPS Tolerance PVs ######################
# 21-Aug-2013: K. Luchini
# Changed from bi to bo records
# so we can set closed loop, to restrict userse
# from easily changing these vaules.
#
record(bo, "XCOR:DOG:408:INTOL") {
  field(DESC, "BACT within MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:408:MPSLIMITS.VALA")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:408:INTOL_BMIN") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:408:MPSLIMITS.VALB")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:408:INTOL_BMIN2") {
  field(DESC, "MPS tol #2")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:408:MPSLIMITS.VALD")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

record(bo, "XCOR:DOG:408:INTOL_BRANGE") {
  field(DESC, "MPS tol")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "closed_loop")
  field(DOL, "XCOR:DOG:408:MPSLIMITS.VALC")
  field(ONAM, "OK")
  field(ZNAM, "FAULT")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  field(ASG, "NOWRITE")
  info(autosaveFields,"VAL")
}

#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(calc, "XCOR:DOG:408:CHCKITOL") {
  field(DESC, "Absolute Check I Tolerance")
  field(EGU, "A")
  field(FLNK, "XCOR:DOG:408:TRIMITOL")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:DOG:408:CHCKBTOL")
  field(INPB, "XCOR:DOG:408:POLYCOEF.B")
  field(PREC, "9")
}

record(calc, "XCOR:DOG:408:TRIMBTOL") {
  field(EGU, "kG-m")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(DESC, "Absolute Trim Tolerance")
  field(CALC, "ABS(A)/2")
  field(INPA, "XCOR:DOG:408:CHCKBTOL")
  field(FLNK, "XCOR:DOG:408:CHCKITOL")
}

record(calc, "XCOR:DOG:408:CHCKBTOL") {
  field(DESC, "Check absolute tolerance")
  field(EGU, "A")
  field(PREC, "9")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(FLNK, "XCOR:DOG:408:TRIMBTOL")
  field(CALC, "MAX(ABS(A),ABS(C))*(B/1000000)")
  field(INPA, "XCOR:DOG:408:BDES.HOPR")
  field(INPB, "XCOR:DOG:408:STABILITY")
  field(INPC, "XCOR:DOG:408:BDES.LOPR")
}

record(longout, "XCOR:DOG:408:STABILITY") {
  field(DESC, "Long Term Stability")
  field(PINI, "YES")
  field(VAL, "1000")
  field(EGU, "ppm")
  field(DRVH, "3000")
  field(DRVL, "100")
  field(HOPR, "3000")
  field(LOPR, "100")
  field(FLNK, "XCOR:DOG:408:CHCKBTOL")
}

record(calc, "XCOR:DOG:408:TRIMITOL") {
  field(DESC, "Absolute Trim I Tolerance")
  field(EGU, "kG-m")
  field(CALC, "ABS(A*B)")
  field(INPA, "XCOR:DOG:408:POLYCOEF.B")
  field(INPB, "XCOR:DOG:408:TRIMBTOL")
  field(PREC, "9")
}

record(ai, "XCOR:DOG:408:TRIMBTOLR") {
  field(DESC, "Relative trim tol")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

record(ai, "XCOR:DOG:408:CHCKBTOLR") {
  field(DESC, "Relative chck tol")
  field(VAL, "0")
  field(PREC, "4")
  field(EGU, "%")
  field(HOPR, "1.0")
  field(LOPR, "0.0")
  field(PINI, "YES")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../../dbd/mgntSoft.dbd")
#! DBDEND



record(bo, "XCOR:DOG:408:FBCKFCOM") {
  field(ZNAM, "CA")
  field(ONAM, "FCOM")
  field(DESC, "CA Mode")
  field(PINI, "YES")
  field(SDIS, "0") 
}

record(bo, "XCOR:DOG:408:PAU") {
  field(ZNAM, "NotConfigured")
  field(ONAM, "Configured")
  field(DESC, "PAU Present")
  field(PINI, "YES")
  field(SDIS, "0")
  field(FLNK, "XCOR:DOG:408:PAUGO")  
}

record(fanout, "XCOR:DOG:408:PAUGO") {
  field(DESC, "PAU control")
  field(LNK1, "XCOR:DOG:408:PAUSTOP")
  field(LNK2, "XCOR:DOG:408:PAUSTART")
}
 
# Note the default is for no feedback in which 
# case the macro LNK=#. If there is feedback,
# which requires an evr and the 2nd lan port
# from the fcom subnet, then set LNK=<blank>
record(seq, "XCOR:DOG:408:PAUSTART") {
  field(DESC, "Setup for PAU On")
  field(SDIS, "XCOR:DOG:408:PAU.RVAL")
  field(DISV, "0")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "1")
  field(DLY3, "1")
#  field(LNK1, "MCOR:EXT:216:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:216:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

record(seq, "XCOR:DOG:408:PAUSTOP") {
  field(DESC, "Setup for PAU Off")
  field(SDIS, "XCOR:DOG:408:PAU.RVAL")
  field(DISV, "1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "0")
#  field(LNK1, "MCOR:EXT:216:ISETPT.DISV")
#  field(LNK2, "MCOR:EXT:216:VSETPT.DISV")
#  field(LNK3, "$(FB)ACTPAU PP")
}

# Change attribute to PSDEVNAME
record(stringout, "XCOR:DOG:408:MCORDEVNAME") {
   field(DESC, "PS device name")
   field(PINI, "YES")
   field(DTYP, "Soft Channel")
   field(VAL, "MCOR:EXT:216:")
 }
 
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:DOG:408:HSTASUB") {
  field(DESC, "Transform EPICS to SLC HSTA")
  field(SCAN, "2 second")
  field(INAM, "mgntInit")
  field(SNAM, "mgntHstaEncode")

# Inputs:
# A = not used
# B = ps type  0=bipolar, 1=unipolar, 2=unipolar w/polarity switch,  no pwr supply
# C = ps turned off by operator  0=no, 1=yes
# D = magnet configuration 0=main,1=string-slave,2=string-main.
# E = ps catagory 0=small,1=intermediate,2=bulk,3=modulator,4=none.
# F = Interlock status (0=OK, s1=FAULT)
# J = PS On/Off state
#
# Outputs:
# Z = SLC HSTA bitmask
#
  field(INPB, "XCOR:DOG:408:PSTYPE.RVAL")
  field(INPC, "XCOR:DOG:408:TURNEDOFF.RVAL")
  field(INPD, "XCOR:DOG:408:CONFIG.RVAL")
  field(INPE, "XCOR:DOG:408:PSCATEGORY.RVAL")
  field(INPF, "XCOR:DOG:408:INTLKSUMY")
# For EF Correctors if set to 1
  field(INPG, "XCOR:DOG:408:AUTOCTRL.RVAL")
  field(INPJ, "XCOR:DOG:408:OUTOFSERVICE.RVAL")
  field(INPL, "XCOR:DOG:408:STATE.RVAL")

# This pv flags matlab feedback control
  field(INPN, "XCOR:DOG:408:FBCKENABLE.RVAL")

# This pv flags pattern aware.
  field(INPO, "XCOR:DOG:408:PAU")
  field(INPP, "XCOR:DOG:408:CALBDISABLE.RVAL")
  field(INPQ, "XCOR:DOG:408:PTRBDISABLE.RVAL")
  field(INPR, "XCOR:DOG:408:TRIMDISABLE.RVAL")
  field(INPS, "XCOR:DOG:408:STDZDISABLE.RVAL)")
  
# added FBCK to HSTA, which flags fast feedback control 
  field(INPT, "XCOR:DOG:408:FBCK")
  field(INPU, "XCOR:DOG:408:TRIMTYPE.RVAL")
  field(INPV, "XCOR:DOG:408:STDZDIRECT.RVAL")
  field(INPW, "XCOR:DOG:408:DEGAUSENABLE.RVAL")
  field(FLNK, "XCOR:DOG:408:HSTA")
}

record(longin, "XCOR:DOG:408:HSTA") {
  field(DESC, "HSTA from EPICS")
  field(INP, "XCOR:DOG:408:HSTASUB")
}

# Only magnets with bipolary power supplies can be degaussed.
record(bo, "XCOR:DOG:408:DEGAUSENABLE") {
  field(DESC, "Degauss Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}


# This is currently only used for cryo magnets.
# If the a the degauss is enabled and degauss
# will be lost when upon a trim request, a
# degauss will be preformed proir the trim
# if this pv is enabled.
record(bo, "XCOR:DOG:408:DEGAUSAUTOENABLE") {
  field(DESC, "Auto DEGAUS Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(VAL, "0")
  field(PINI, "YES")
}


# EPSC's have auto a calibration in firmware running continuously.
# So for EPSC's the default is for calibration to be enabled. However,
# For MCOR's the DAC calibration is performed in software (mgntCtrl.st)
#
record(bo, "XCOR:DOG:408:CALBDISABLE") {
  field(DESC, "DAC Calb Disabled")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL,  "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:408:PTRBDISABLE") {
  field(DESC, "Perturb Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:408:TRIMDISABLE") {
  field(DESC, "Trim Function")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Enabled")
  field(ONAM, "Disabled")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(bo, "XCOR:DOG:408:STDZDISABLE") {
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(DESC, "Standardize Function")
  field(VAL, "1")
  field(PINI, "YES")
  info(autosaveFields,"VAL RVAL")
}

# This PV has been replaced by XCOR:DOG:408:FBCK.
# Only the matlab feedback currently uses this PV as of 11/07/2012.
# The feedback controller software only uses XCOR:DOG:408:FBCK.
# This PV should be replaced by XCOR:DOG:408:FBCK in the matlab feedback
# and removed from the magnets sequence mgntCtrl.st and database.
# The matlab feeback should do the same thing as the feedback controller
# software for non-fast feedback devices, which use the  CA subnet and
# note the fast-feedback subnet FCOM to control the magnets..
#
record(bo, "XCOR:DOG:408:FBCKENABLE") {
  field(DESC, "Feedback Enable")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(PINI, "YES")
  field(VAL,  "0")
  info(autosaveFields,"VAL RVAL")
}

# Note: this pv iset seot to Enabled for
# earth field correctors.
record(bo, "XCOR:DOG:408:AUTOCTRL") {
  field(DESC, "Automatically controlled")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:DOG:408:OUTOFSERVICE") {
  field(DESC, "Device Offline flag")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "In-Service")
  field(ONAM, "Out-of-Service")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:408:ONLINECALC")
  info(autosaveFields,"VAL RVAL")
}
record(calcout,"XCOR:DOG:408:ONLINECALC")
{
  field(DESC, "Device online status")
  field(ASG,  "Internal")
  field(CALC, "A?0:1")
  field(INPA, "XCOR:DOG:408:OUTOFSERVICE NPP NMS")
  field(OUT,  "XCOR:DOG:408:ONLINE PP")
}
record(bo, "XCOR:DOG:408:ONLINE") {
  field(DESC, "PS Online Status")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "OFFLINE")
  field(ONAM, "ONLINE")
  field(OUT,  "")
}

record(bo, "XCOR:DOG:408:ONOFFCTRL") {
  field(DESC, "PS on/off ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

record(bo, "XCOR:DOG:408:RESETCTRL") {
  field(DESC, "PS fault reset ctrl avail")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "1")
}

record(bo, "XCOR:DOG:408:NOANLGCTRL") {
  field(DESC, "No analog control of ps")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  field(VAL, "0")
}

# This PV is modified by <dev>:STATSUB.U
record(bo, "XCOR:DOG:408:UNAVAIL") {
  field(DESC, "Not avail for control")
  field(DTYP, "Raw Soft Channel")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZNAM, "Available")
  field(ONAM, "Unavailable")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
}

record(bo, "XCOR:DOG:408:PPS") {
  field(DESC, "Monitored by PPS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL")
}

# 21-Aug-2013: K. Luchini
# Set channel access security so that
# users cannot easily enable/disable MPS.
# This pv is need for binary status 
# pvs in magnet databases, which are
# are accessd the MPS Link Node over 
# Channel Access.
record(mbbo, "XCOR:DOG:408:MPS") {
  field(DESC, "Monitored by MPS")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(ZRST, "NONE")
  field(ONST, "PSON_MON")
  field(TWST, "PSON_BACT_MON")
  field(NOBT, "2")
  field(ASG,  "EOICDESK")
  info(autosaveFields,"VAL")
}

# Informational only.
record(bo, "XCOR:DOG:408:BCS") {
  field(DESC, "Monitored by BCS")
  field(ONAM, "YES")
  field(ZNAM, "NO")
  field(PINI, "YES")
  field(ASG,  "NOWRITE")
  info(autosaveFields,"VAL RVAL")
}

# Please note that option 3 "NONE" is set for magnets
# that are considered a slave in a string.
record(mbbo, "XCOR:DOG:408:PSTYPE") {
  field(DESC, "Power Supply Type")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Bipolar")
  field(ONST, "Unipolar")
  field(TWST, "Unipolar_PolSW")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:408:PSCATEGORY"){
  field(DESC, "Power Supply Category")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "Small")
  field(ONST, "Intermediate")
  field(TWST, "Bulk")
  field(THST, "Modulator")
  field(FRST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVSV, "INVALID")
  field(SXSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:408:PSCONTROLLER") {
  field(DESC, "Power Supply Controller")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "3")
  field(ZRST, "MCOR")
  field(ONST, "EMCOR")
  field(TWST, "EPSC")
  field(THST, "PLC")
  field(FRST, "BECKHOFF")
  field(FVST, "SERIAL")
  field(SXST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(FVVL, "5")
  field(SXVL, "6")
  field(SVVL, "7")
  field(SVSV, "INVALID")
  field(VAL,  "1")
  field(ASG,  "NOWRITE")
}

record(mbbo, "XCOR:DOG:408:CONFIG") {
  field(DESC, "Magnet Configuration")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "Individual")
  field(ONST, "String")
  field(TWST, "String Main")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")  
  field(THSV, "INVALID")
  field(VAL,  "0")
  field(ASG,  "NOWRITE")
  field(FLNK, "XCOR:DOG:408:TRIMTYPE")
}

record(stringout, "XCOR:DOG:408:MAIN") {
  field(DESC, "Magnet Main")
  field(ASG,  "NOWRITE")
  field(PINI, "YES")
  field(DOL,  "XCOR:DOG:408:MADNAME CPP NMS")
  field(OMSL, "closed_loop")
  field(VAL,  " ")
}

record(calcout, "XCOR:DOG:408:TURNEDOFFCALC") {
  field(DESC, "Check if ps turned off")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?0:1")
  field(INPA, "XCOR:DOG:408:STATE.RVAL")
  field(INPB, "XCOR:DOG:408:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:DOG:408:TURNEDOFF PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:DOG:408:TURNEDOFF") {
  field(DESC, "Supply Turned Off by User")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

# If PSs is on then clear Tripped flag.
# Otherise, if the ps is off and the 
# the ps wasn't turned off intentionally,
# then consider that the ps has tripped.
record(calcout, "XCOR:DOG:408:TRIPPEDCALC") {
  field(DESC, "Check if ps tripped")
  field(SCAN, "10 second")
  field(CALC, "A?0:B?1:0")
  field(INPA, "XCOR:DOG:408:STATE.RVAL")
  field(INPB, "XCOR:DOG:408:INTLKSUMY.RVAL")
  field(OUT,  "XCOR:DOG:408:TRIPPED PP")
  field(OOPT, "On Change")
  field(ASG, "Internal")
}

record(bo, "XCOR:DOG:408:TRIPPED") {
  field(DESC, "Supply Tripped")
  field(PINI, "YES")
  field(ZNAM, "NO")
  field(ONAM, "YES")
  info(autosaveFields,"VAL RVAL")
}

record(ao, "XCOR:DOG:408:PSONDLY") {
 field(DESC, "Turn On delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "20")
}

record(ao, "XCOR:DOG:408:PSOFFDLY") {
 field(DESC, "Turn Off delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "10")
}

# Note: This pv is only used for EPSCs and EMCOR's
# and 50b1 seems to like this set to 20 sec.
record(ao, "XCOR:DOG:408:RAMPSTARTDLY") {
 field(DESC, "Tansition to ramp delay")
 field(PINI,  "YES")
 field(PREC,  "4")
 field(EGU,   "secs")
 field(VAL,   "0")
}

######### For PSTYPE=2 Only  #############

record(mbbo, "XCOR:DOG:408:REVSWSTATE") {
  field(DESC, "Reversing Switch Status")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(NOBT, "2")
  field(ZRST, "NORMAL")
  field(ONST, "REVERSE")
  field(TWST, "MOVING")
  field(THST, "Not Available")
  field(TWSV, "MINOR")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
#
# If PSTYPE=2 (unipolar supply with polarity switch)
# then change DOL=<ps>:REVSWSTATE
  field(DOL,  "2")
  field(OMSL, "closed_loop")
}

record(bo, "XCOR:DOG:408:REVSWSET") {
  field(DESC, "Reversing Switch Set")
  field(DTYP, "Raw Soft Channel")
  field(ZNAM, "NORMAL")
  field(ONAM, "REVERSE")
  field(PINI, "YES")
}

#! TextBox(TB0,1860,1540,2180,1600,0,"Dialog",12,1,16777215,"SLC aware code writes SLC HSTA to HSTACTRL",null)
#! TextBox(TB5,1940,2160,2200,2280,0,"Dialog",12,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,1880,2000,2300,2120,0,"Dialog",14,1,16777215,"HSTA - hardware status\n\nHSTACTRL contains HSTA from SLC\nHSTACTRLSUB parses significant bits \nHSTACTRLSEQ links to the control bo's - fill in later - only 3 connected now\n\n\n\n",null)
#! TextBox(TB1,1880,1660,2180,1980,0,"Dialog",12,1,16777215,"XCOR:DOG:408:HSTACTRLSUB \nDecode HSTACTRL & link to significant bo's:\ns \nOutputs:\nI - Completely Happy\nJ - Out of Service\nK - In Trouble\nL - Turned off by Operator\nM - Polarity Reversed\nN - Feedback Control\nO - Mini-Stdz Required(always mini-stdz on trim if stdz enabled)\nP - Calib Disabled\nQ - Perturb Disabled\nR - Trim Disabled\nS - Stdz Disabled\nT - No retry on Trim - hook to trimtype\nU - IVBUp(=o) down(=1)\nV - Shunt/booster \nW - No AUTO TRIM (not used)\n",null)
#! Record("XCOR:DOG:408:TURNEDOFF",3140,1907,0,1,"XCOR:DOG:408:TURNEDOFF")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(sSub, "XCOR:DOG:408:STATSUB") {
  field(DESC, "Build STATus ")
  field(INAM, "mgntInit")
  field(SNAM, "mgntSlcStat")
  field(INPA, "XCOR:DOG:408:BACT.STAT")
  field(INPB, "XCOR:DOG:408:BDES.STAT")
  field(INPC, "XCOR:DOG:408:IRIPL.STAT")
  field(INPD, "MCOR:EXT:216:ISETPT_S.STAT")
  field(INPE, "MCOR:EXT:216:IACT.STAT")
# INPF is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.STAT
# if used for EFC correctors set to <useg>:GapAct.STAT
  field(INPF, "")
  field(INPG, "XCOR:DOG:408:BACT.SEVR")
  field(INPH, "XCOR:DOG:408:BDES.SEVR")
  field(INPI, "XCOR:DOG:408:IRIPL.SEVR")
  field(INPJ, "MCOR:EXT:216:ISETPT_S.SEVR")
  field(INPK, "MCOR:EXT:216:IACT.SEVR")
#
# INPL is used to propagate BCON to lclshome for selective magnets.
# if used for standard magnet set to <dev>:BCON.SEVR
# if used for EFC correctors set to <useg>GapAct.SEVR
  field(INPL, "")
  field(INPM, "XCOR:DOG:408:STATE.RVAL")
  field(INPN, "XCOR:DOG:408:STDZOK")
  field(INPO, "XCOR:DOG:408:CALBOK")
  field(INPP, "XCOR:DOG:408:OUTOFSERVICE.RVAL")
  field(INPQ, "XCOR:DOG:408:CONFIG.RVAL")
  field(INPR, "XCOR:DOG:408:HSTA")
  field(INPS, "XCOR:DOG:408:CTRL.RVAL")
  field(INPT, "XCOR:DOG:408:DEGAUSOK") 
  field(INPV, "XCOR:DOG:408:INTLKSUMY")
#
# INPY is used to for kicker trigger status. If the kicker plc
# has disabled trigger to the modulator, the ps can still be on
# and trimmed nothing is being sent out to the magnet.
# So the default is the TRIG macro is blank, unless this is a kicker
# that has a trigger status.
  field(INPY, "")
# Outputs
# U - Input to UNAVAIL via UNAVAILGO seq record
# W = worst STAT (BACT,BDES,RIPL,ISETPT,IACT,BCON)
# X = worst SEVR (BACT,BDES,RIPL,ISETPT,IACT,BCON)
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:408:STAT")
}

record(longout, "XCOR:DOG:408:STAT") {
  field(DESC, "STAT sent to SLC")
  field(SCAN, "Passive")
  field(FLNK, "XCOR:DOG:408:STATCTRLSUB")
  field(DOL, "XCOR:DOG:408:STATSUB.VAL")
  field(OMSL, "closed_loop")
}

record(sSub, "XCOR:DOG:408:STATCTRLSUB") {
  field(DESC, "Decode SLC STAT into mbbo")
  field(INAM, "mgntInit")
  field(SNAM, "mgntStatDecode")
  field(INPA, "XCOR:DOG:408:STAT")
  field(INPB, "XCOR:DOG:408:HSTA")
  field(INPD, "XCOR:DOG:408:ONOFFCTRL.RVAL")
  field(FLNK, "XCOR:DOG:408:STATMSG")
}

record(mbbo, "XCOR:DOG:408:STATMSG") {
  field(DESC, "Status Message - worst case")
  field(NOBT, "16")
  field(ZRST, "Good")
  field(ONST, "BCON Warning")
  field(TWST, "Offline")
  field(THST, "PAU Ctrl")
  field(FRST, "Turned Off")
  field(FVST, "Not Degaus'd")
  field(SXST, "Not Cal'd")
  field(SVST, "Feedback Ctrl")
  field(EIST, "PS Tripped")
  field(NIST, "DAC Error")
  field(TEST, "ADC Error")
  field(ELST, "Not Stdz'd")
  field(TVST, "Out-of-Tol")
  field(TTST, "BAD Ripple")
  field(FTST, "BAD BACT")
  field(FFST, "No Control")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "NO_ALARM")
  field(THSV, "MINOR")
  field(FRSV, "MAJOR")
  field(FVSV, "MINOR")
  field(SXSV, "MINOR")
  field(SVSV, "NO_ALARM")
  field(EISV, "MAJOR")
  field(NISV, "MAJOR")
  field(TESV, "MAJOR")
  field(ELSV, "MINOR")
  field(TVSV, "MAJOR")
  field(TTSV, "MINOR")
  field(FTSV, "MAJOR")
  field(FFSV, "NO_ALARM")
  field(OMSL, "closed_loop")
  field(FLNK, "XCOR:DOG:408:UNAVAILGO")
  field(DOL, "XCOR:DOG:408:STATCTRLSUB.W")
}

record(seq, "XCOR:DOG:408:UNAVAILGO") {
  field(DESC, "Process UNAVAIL")
  field(DOL1, "XCOR:DOG:408:STATSUB.U")
  field(LNK1, "XCOR:DOG:408:UNAVAIL PP")
}

record(stringout, "XCOR:DOG:408:SNLSTATMSG") {
  field(DTYP, "Soft Channel")
}


#! TextBox(TB0,820,1000,1200,1220,0,"Dialog",12,1,16777215,"XCOR:DOG:408:STATUSSUB - future\nOverall device status - takes input from action snls, record sevrs, master snl(s) and outputs final status\n\nInputs:\nA - XCOR:DOG:408:CTRLSTATUS - snl status\nB - MGNT:CTRLSTATUS - master list status\nC\nD - XCOR:DOG:408:SEVRSTATUS (future)",null)
#! TextBox(TB9,1300,900,1680,1140,0,"Dialog",12,1,16777215,"STATDECODE is used for HSTA/STAT\nDiagnostic Display only",null)
#! TextBox(TB8,1360,960,1540,1260,0,"Dialog",12,1,16777215,"Inputs:\nA - STAT\nOutputs:\nH -  STAT_GOOD\nI -  STAT_OK\nJ -  STAT_DEAD\nK -  STAT_SICK\nL -  STAT_OFF\nM -  STAT_STDZOK\nN -  STAT_CALOK\nO -  STAT_DRIFTING\nP -  STAT_DBERR\nQ -  STAT_DACERR\nR -  STAT_ADCERR\nS -  STAT_BADCUR\nT -  STAT_OUTTOL\nU -  STAT_BADRIPL\nV -  STAT_BADBACT",null)
#! TextBox(TB5,1680,960,1960,1080,0,"Dialog",18,1,16777215,"Macros:\nDEV = DEVICE:AREA:POSN\nDEVICE = BEND, QUAD, *COR, etc\nMGNT = MGNT\nAREA = area\nPOSN = position\n",null)
#! TextBox(TB3,800,1180,1320,1300,0,"Dialog",14,1,16777215,"STAT - slc aware\n\nSTATSUB formats control bo's into STAT for SLC\nSTATSUBSEQ gets STATSUB outputs to STAT \n\n\n",null)
#! TextBox(TB2,780,620,980,1000,0,"Dialog",12,1,16777215,"XCOR:DOG:408STATSUB\nformat control bo's into slc STAT\n\nInputs:\nA - XCOR:DOG:408:STATUS\nC - XCOR:DOG:408:ON\nD - XCOR:DOG:408:STDZOK\nE - XCOR:DOG:408:CALBOK\nF - XCOR:DOG:408:BACTDRIFT (future)\nG -\nH- XCOR:DOG:408:DACSTATUS\nI -XCOR:DOG:408:ADCSTATUS\nJ - XCOR:DOG:408:BACTSTATUS\nK - XCOR:DOG:408:BDESSTATUS\nL - XCOR:DOG:408:RIPLSTATUS\n\nOutput:\nP - XCOR:DOG:408:STAT - slc STAT\n",null)
#! TextBox(TB1,1520,680,1980,840,0,"Dialog",12,1,16777215,"Note:\nThere will most likely be a sub record for each of:\nADC record's .SEVR and .STAT -> ADCSTATUS\nDAC record's .SEVR and .STAT -> DACSTATUS\nBACT record's .SEVR and .STAT -> BACTSTATUS\nBDES record's .SEVR and .STAT -> BDESSTATUS\n?RIPL record's .SEVR and .STAT -> RIPLSTATUS\n -- above is all done in STATSUB",null)
record(ao, "XCOR:DOG:408:PROGRESS") {
  field(DESC, "Function Progress")
  field(VAL, "0")
  field(EGU, "percent")
  field(DRVH, "100")
  field(DRVL, "0")
  field(HOPR, "100")
  field(LOPR, "0")
}

record(bo, "XCOR:DOG:408:DEBUG") {
  field(ZNAM, "OFF")
  field(ONAM, "ON")
  field(PINI, "YES")
}

#
# Used by higher level software to determine how to use PVs associated
# with the device.  This record is manually set by operations when the 
# state of the device changes.
# For example: Ops thinks the device is broken in some way.  
# They write an Artemis and put the device in MAINTENANCE.  
# The hardware guys fix the problem, solve the Artemis and put the 
# device in CHECKOUT.  Ops decides whether the device is working and 
# either marks it ONLINE or back to MAINTENANCE.
#
record(mbbo, "XCOR:DOG:408:ACCESS")
{
  field(DESC, "Usage Mode")
  field(PINI, "YES")
# Online - this device is operational, working normally, and ready to 
# be used by higher level software.
  field(ZRST, "Online")
  field(ZRSV, "NO_ALARM")
# Maintenance - this device is in a maintenance state (being worked on by 
# controls) where maintainers can see how it is performing, but should not 
# be used by most higher level software.
  field(ONST, "Maintenance")
  field(ONSV, "MINOR")
# Checkout - This device has had maintenance work done and is back in 
# production for 'check out' purposes by operations before it's released 
# for normal use.  Some higher level software may use it.
  field(TWST, "Checkout")
  field(TWSV, "MINOR")
# Offline - device is broken and should not be used by any higher level
# software.
  field(THST, "Offline")
  field(THSV, "MAJOR")
}
#
# Used by higher level software to determine if a PV is in feedback or not.
# May also be used by actuator (magnet and RF) IOC applications to 
# switch output records to "closed_loop" to prevent outside programs from
# changing setpoints when an actuator device is in feedback.
#
record(mbbo, "XCOR:DOG:408:FBCK")
{
  field(DESC, "Feedback State")
  field(PINI, "YES")
  field(VAL, "2")
# Off - this device can be used in feedback but all feedback loops 
# using it are off.
  field(ZRST, "Off")
# On - this device is being used by one or more feedback loops.
  field(ONST, "On")
# Unavailable - this device is not used by any feedback loop.
  field(TWST, "Unavailable")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "XCOR:EXT:368:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "XCX01")
 }

record(stringout, "XCOR:EXT:368:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "CLASS-4")
}

record(sub, "XCOR:EXT:368:POLYCOEF") {
  field(DESC, "XCOR:EXT:368 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "XCOR:EXT:368:POLYCOEFNUM")
}

record(longin, "XCOR:EXT:368:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "XCOR:EXT:368:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "XCOR:EXT:368:COEF2IVB")
}

record(sub, "XCOR:EXT:368:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "XCOR:EXT:368:POLYCOEF")
  field(INPB, "XCOR:EXT:368:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "XCOR:EXT:368:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "XCOR:EXT:368:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "YCOR:EXT:762:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "YCX02")
 }

record(stringout, "YCOR:EXT:762:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "CLSSS-4")
}

record(sub, "YCOR:EXT:762:POLYCOEF") {
  field(DESC, "YCOR:EXT:762 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "YCOR:EXT:762:POLYCOEFNUM")
}

record(longin, "YCOR:EXT:762:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "YCOR:EXT:762:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "YCOR:EXT:762:COEF2IVB")
}

record(sub, "YCOR:EXT:762:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "YCOR:EXT:762:POLYCOEF")
  field(INPB, "YCOR:EXT:762:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "YCOR:EXT:762:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "YCOR:EXT:762:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "YCOR:DOG:113:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "YCDOG0")
 }

record(stringout, "YCOR:DOG:113:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "TYPE-4")
}

record(sub, "YCOR:DOG:113:POLYCOEF") {
  field(DESC, "YCOR:DOG:113 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:113:POLYCOEFNUM")
}

record(longin, "YCOR:DOG:113:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "YCOR:DOG:113:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "YCOR:DOG:113:COEF2IVB")
}

record(sub, "YCOR:DOG:113:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "YCOR:DOG:113:POLYCOEF")
  field(INPB, "YCOR:DOG:113:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "YCOR:DOG:113:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "YCOR:DOG:113:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "XCOR:DOG:116:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "XCDOG1")
 }

record(stringout, "XCOR:DOG:116:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "TYPE-4")
}

record(sub, "XCOR:DOG:116:POLYCOEF") {
  field(DESC, "XCOR:DOG:116 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:116:POLYCOEFNUM")
}

record(longin, "XCOR:DOG:116:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "XCOR:DOG:116:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "XCOR:DOG:116:COEF2IVB")
}

record(sub, "XCOR:DOG:116:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "XCOR:DOG:116:POLYCOEF")
  field(INPB, "XCOR:DOG:116:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "XCOR:DOG:116:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "XCOR:DOG:116:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "YCOR:DOG:137:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "YCDOG2")
 }

record(stringout, "YCOR:DOG:137:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "TYPE-4")
}

record(sub, "YCOR:DOG:137:POLYCOEF") {
  field(DESC, "YCOR:DOG:137 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:137:POLYCOEFNUM")
}

record(longin, "YCOR:DOG:137:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "YCOR:DOG:137:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "YCOR:DOG:137:COEF2IVB")
}

record(sub, "YCOR:DOG:137:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "YCOR:DOG:137:POLYCOEF")
  field(INPB, "YCOR:DOG:137:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "YCOR:DOG:137:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "YCOR:DOG:137:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "XCOR:DOG:148:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "XCDOG3")
 }

record(stringout, "XCOR:DOG:148:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "TYPE-4")
}

record(sub, "XCOR:DOG:148:POLYCOEF") {
  field(DESC, "XCOR:DOG:148 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:148:POLYCOEFNUM")
}

record(longin, "XCOR:DOG:148:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "XCOR:DOG:148:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "XCOR:DOG:148:COEF2IVB")
}

record(sub, "XCOR:DOG:148:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "XCOR:DOG:148:POLYCOEF")
  field(INPB, "XCOR:DOG:148:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "XCOR:DOG:148:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "XCOR:DOG:148:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "YCOR:DOG:163:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "YCDOG4")
 }

record(stringout, "YCOR:DOG:163:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "TYPE-4")
}

record(sub, "YCOR:DOG:163:POLYCOEF") {
  field(DESC, "YCOR:DOG:163 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:163:POLYCOEFNUM")
}

record(longin, "YCOR:DOG:163:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "YCOR:DOG:163:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "YCOR:DOG:163:COEF2IVB")
}

record(sub, "YCOR:DOG:163:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "YCOR:DOG:163:POLYCOEF")
  field(INPB, "YCOR:DOG:163:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "YCOR:DOG:163:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "YCOR:DOG:163:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "XCOR:DOG:178:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "XCDOG5")
 }

record(stringout, "XCOR:DOG:178:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "TYPE-4")
}

record(sub, "XCOR:DOG:178:POLYCOEF") {
  field(DESC, "XCOR:DOG:178 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:178:POLYCOEFNUM")
}

record(longin, "XCOR:DOG:178:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "XCOR:DOG:178:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "XCOR:DOG:178:COEF2IVB")
}

record(sub, "XCOR:DOG:178:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "XCOR:DOG:178:POLYCOEF")
  field(INPB, "XCOR:DOG:178:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "XCOR:DOG:178:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "XCOR:DOG:178:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "YCOR:DOG:193:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "YCDOG6")
 }

record(stringout, "YCOR:DOG:193:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "TYPE-4")
}

record(sub, "YCOR:DOG:193:POLYCOEF") {
  field(DESC, "YCOR:DOG:193 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:193:POLYCOEFNUM")
}

record(longin, "YCOR:DOG:193:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "YCOR:DOG:193:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "YCOR:DOG:193:COEF2IVB")
}

record(sub, "YCOR:DOG:193:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "YCOR:DOG:193:POLYCOEF")
  field(INPB, "YCOR:DOG:193:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "YCOR:DOG:193:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "YCOR:DOG:193:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "XCOR:DOG:212:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "XCDOG7")
 }

record(stringout, "XCOR:DOG:212:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "TYPE-4")
}

record(sub, "XCOR:DOG:212:POLYCOEF") {
  field(DESC, "XCOR:DOG:212 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:212:POLYCOEFNUM")
}

record(longin, "XCOR:DOG:212:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "XCOR:DOG:212:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "XCOR:DOG:212:COEF2IVB")
}

record(sub, "XCOR:DOG:212:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "XCOR:DOG:212:POLYCOEF")
  field(INPB, "XCOR:DOG:212:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "XCOR:DOG:212:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "XCOR:DOG:212:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "YCOR:DOG:227:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "YCDOG8")
 }

record(stringout, "YCOR:DOG:227:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "TYPE-4")
}

record(sub, "YCOR:DOG:227:POLYCOEF") {
  field(DESC, "YCOR:DOG:227 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:227:POLYCOEFNUM")
}

record(longin, "YCOR:DOG:227:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "YCOR:DOG:227:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "YCOR:DOG:227:COEF2IVB")
}

record(sub, "YCOR:DOG:227:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "YCOR:DOG:227:POLYCOEF")
  field(INPB, "YCOR:DOG:227:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "YCOR:DOG:227:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "YCOR:DOG:227:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "XCOR:DOG:252:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "XCL1P")
 }

record(stringout, "XCOR:DOG:252:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "TYPE-4")
}

record(sub, "XCOR:DOG:252:POLYCOEF") {
  field(DESC, "XCOR:DOG:252 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:252:POLYCOEFNUM")
}

record(longin, "XCOR:DOG:252:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "XCOR:DOG:252:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "XCOR:DOG:252:COEF2IVB")
}

record(sub, "XCOR:DOG:252:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "XCOR:DOG:252:POLYCOEF")
  field(INPB, "XCOR:DOG:252:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "XCOR:DOG:252:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "XCOR:DOG:252:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "YCOR:DOG:281:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "YCL2P")
 }

record(stringout, "YCOR:DOG:281:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "TYPE-4")
}

record(sub, "YCOR:DOG:281:POLYCOEF") {
  field(DESC, "YCOR:DOG:281 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:281:POLYCOEFNUM")
}

record(longin, "YCOR:DOG:281:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "YCOR:DOG:281:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "YCOR:DOG:281:COEF2IVB")
}

record(sub, "YCOR:DOG:281:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "YCOR:DOG:281:POLYCOEF")
  field(INPB, "YCOR:DOG:281:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "YCOR:DOG:281:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "YCOR:DOG:281:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "XCOR:DOG:338:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "XCL3P")
 }

record(stringout, "XCOR:DOG:338:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "TYPE-4")
}

record(sub, "XCOR:DOG:338:POLYCOEF") {
  field(DESC, "XCOR:DOG:338 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:338:POLYCOEFNUM")
}

record(longin, "XCOR:DOG:338:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "XCOR:DOG:338:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "XCOR:DOG:338:COEF2IVB")
}

record(sub, "XCOR:DOG:338:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "XCOR:DOG:338:POLYCOEF")
  field(INPB, "XCOR:DOG:338:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "XCOR:DOG:338:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "XCOR:DOG:338:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "YCOR:DOG:357:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "YCL4P")
 }

record(stringout, "YCOR:DOG:357:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "TYPE-4")
}

record(sub, "YCOR:DOG:357:POLYCOEF") {
  field(DESC, "YCOR:DOG:357 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "YCOR:DOG:357:POLYCOEFNUM")
}

record(longin, "YCOR:DOG:357:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "YCOR:DOG:357:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "YCOR:DOG:357:COEF2IVB")
}

record(sub, "YCOR:DOG:357:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "YCOR:DOG:357:POLYCOEF")
  field(INPB, "YCOR:DOG:357:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "YCOR:DOG:357:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "YCOR:DOG:357:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

# Comment out the bar code pv by setting the macor
# LNK="#" for the kicker I vs V poly coef
 record(stringout, "XCOR:DOG:408:BARCODE") {
  field(DESC, "SLAC Barcode on Magnet")
  field(PINI, "YES")
  field(VAL, "XCL5P")
 }

record(stringout, "XCOR:DOG:408:ENGNAME") {
  field(DESC, "Magnet Engineering Name")
  field(PINI, "YES")
  field(VAL, "TYPE-4")
}

record(sub, "XCOR:DOG:408:POLYCOEF") {
  field(DESC, "XCOR:DOG:408 Poly Coefs")
  field(INAM, "mgntNumPolyCoef")
  field(SNAM, "mgntNumPolyCoef")
  field(PREC, "8")
  field(A, "0")
  field(B, "95.3")
  field(C, "0")
  field(D, "0")
  field(E, "0.0")
  field(F, "0.0")
  field(G, "0.0")
  field(H, "0.0")
  field(I, "0.0")
  field(J, "0.0")
  field(K, "0.0")
  field(L, "0.0")
  field(PINI, "YES")
  field(FLNK, "XCOR:DOG:408:POLYCOEFNUM")
}

record(longin, "XCOR:DOG:408:POLYCOEFNUM") {
  field(DESC, "No. of Poly Coef.")
  field(INP , "XCOR:DOG:408:POLYCOEF.VAL NPP NMS")
  field(LOLO, "0")
  field(LLSV, "MAJOR")
  field(FLNK, "XCOR:DOG:408:COEF2IVB")
}

record(sub, "XCOR:DOG:408:COEF2IVB") {
  field(DESC, "Populate wf w/ poly coef")
  field(PINI, "YES")
  field(INAM, "mgntExplodeInit")
  field(SNAM, "mgntExplode")
  field(INPA, "XCOR:DOG:408:POLYCOEF")
  field(INPB, "XCOR:DOG:408:IVB")

# Need to process IVB so that UDF=0
  field(FLNK, "XCOR:DOG:408:IVB")
}

# Note: this pv was requested by M. Woodley
# so that he coudl get all the ivb poly coefficients
# for a single magnet in one go.
record(waveform, "XCOR:DOG:408:IVB") {
  field(DESC, "Poly coef I vs B")
  field(DTYP, "Soft Channel")
  field(PREC, "8")
  field(NELM, "12")
  field(FTVL, "DOUBLE")
}

#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:201:ISETPT_S") {
	field(DESC, "Chnl 0 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:201:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:201:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:201:ISETPT_RBCK") {
	field(DESC, "Chnl 0 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:201:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:201:IACT") {
#	field(DESC, "Chnl 0 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C0S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:201:IMON") {
	field(DESC, "Chnl 0 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "XCOR:EXT:368:IMON")
}

record(ai, "MCOR:EXT:201:IRIPL") {
	field(DESC, "Chnl 0 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:EXT:368:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:201:IFBCK") {
	field(DESC, "Chnl 0 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:201:IACT") {
	field(DESC, "Chnl 0 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:EXT:368:IACT")
}
record(ai, "MCOR:EXT:201:IFBCK_RIPL") {
	field(DESC, "Chnl 0 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:201:IRANGE_DAC_SET") {
	field(DESC, "Chnl 0 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:201:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:201:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 0 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C0S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:201:IRANGE_ADC_SET") {
	field(DESC, "Chnl 0 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:201:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:201:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 0 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C0S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:201:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 0 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:201:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:201:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 0 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C0S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:201:IRAMPRATE") {
	field(DESC, "Chnl 0 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "XCOR:EXT:368:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:201:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 0 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:201:NSAMP_AVE_S") {
	field(DESC, "Chnl 0 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:201:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:201:NSAMP_AVE_R") {
	field(DESC, "Chnl 0 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:201:CSR_R") {
	field(DESC, "Chnl 0 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:201:CSR")
}

record(longout, "MCOR:EXT:201:CSR_S") {
	field(DESC, "Chnl 0 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:201:CSR_C") {
	field(DESC, "Chnl 0 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:201:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:201:CSR_C PP")
   field(LNK2, "MCOR:EXT:201:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:201:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:201:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:201:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:201:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:201:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:201:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:201:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:201:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:201:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:201:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:201:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:201:TYPE") {
  field(DESC, "Chnl 0 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:201:TYPE_SEQ")
  field(VAL,  "2")
}

record(seq, "MCOR:EXT:201:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:201:CONFIG_SET")
 field(LNK2, "MCOR:EXT:201:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:201:CONFIG_SET")
 field(LNK4, "MCOR:EXT:201:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:201:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:201:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:201:TYPE.RVAL")
  field(INPB, "MCOR:EXT:201:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:201:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:201:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:201:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:201:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:201:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:201:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:201:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:201:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:201:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:201:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:201:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:201:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:201:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:201:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:201:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:201:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:201:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:201:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:201:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:201:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:201:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:201:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:201:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:201:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:201:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:201:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:201:IMON.HOPR")
  field(LNK3, "MCOR:EXT:201:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:201:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:201:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:201:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:201:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:201:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:201:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:201:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:201:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:201:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:201:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:201:IACT.HOPR")
  field(LNK5, "MCOR:EXT:201:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:201:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:201:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "XCOR:EXT:368:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:201:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:201:ISETPT")
  field(INPE, "MCOR:EXT:201:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:201:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:201:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:201:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:201:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:201:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:201:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:201:VSETPT") {
  field(DESC, "Chnl 0 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:201:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:201:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:201:VSETPT_RBCK") {
  field(DESC, "Chnl 0 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:201:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:201:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:201:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:201:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:201:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:201:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:201:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:201:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:201:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:201:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:201:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:201:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:201:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:201:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:201:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:201:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:201:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:201:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:201:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:201:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:201:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:201:CSR_R")
        field(FLNK,  "MCOR:EXT:201:CSR_SEQ")
}

record(seq, "MCOR:EXT:201:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:201:CSR.B5")
        field(DOL2, "MCOR:EXT:201:CSR.B1")
        field(DOL3, "MCOR:EXT:201:CSR.B2")
        field(DOL4, "MCOR:EXT:201:CSR.B3")
        field(DOL5, "MCOR:EXT:201:CSR.B4")
        field(DOL6, "MCOR:EXT:201:CSR.B0")
        field(LNK1, "MCOR:EXT:201:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:201:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:201:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:201:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:201:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:201:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:201:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:201:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:201:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:201:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:201:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:201:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:201:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:201:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:201:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:201:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:201:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:201:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "XCOR:EXT:368:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:201:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:201:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:201:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:201:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:201:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:201:STATE PP")
   field(LNK2,  "MCOR:EXT:201:STATE PP")
   field(LNK3,  "MCOR:EXT:201:STATE PP")
}
record(bo, "MCOR:EXT:201:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:EXT:368:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:201:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:EXT:368:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:201:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:201:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B0 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:201:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:201:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B0 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:201:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:201:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:201:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:201:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:201:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:201:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:201:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:201:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:201:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:201:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:201:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:201:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:201:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:201:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:201:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:201:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "XCOR:EXT:368:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:201:CONFIG_SET") {
  field(DESC, "Chnl 0 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:201:CONFIG_S")
}

record(seq, "MCOR:EXT:201:CONFIG_S") {
   field(DESC, "Chnl 0 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:201:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:201:CSR_C PP")
   field(LNK2, "MCOR:EXT:201:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:201:FBCKMODE_SET") {
  field(DESC, "Chnl 0 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:201:FBCKMODE_S")
}

record(seq, "MCOR:EXT:201:FBCKMODE_S") {
   field(DESC, "Chnl 0 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:201:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:201:CSR_C PP")
   field(LNK2, "MCOR:EXT:201:CSR_S PP")
}

record(mbbo, "MCOR:EXT:201:DACMODE_SET") {
  field(DESC, "Chnl 0 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:201:DACMODE_S")
}

record(seq, "MCOR:EXT:201:DACMODE_S") {
   field(DESC, "Chnl 0 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:201:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:201:CSR_C")
   field(LNK2, "MCOR:EXT:201:CSR_S")
}

record(mbbo, "MCOR:EXT:201:RAMPMODE_SET") {
   field(DESC, "Chnl 0 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:201:RAMPMODE_S")
}

record(seq, "MCOR:EXT:201:RAMPMODE_S") {
   field(DESC,"Chnl 0 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:201:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:201:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:201:CSR_S PP")
   field(LNK3, "MCOR:EXT:201:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:201:STDZMODE_SET") {
  field(DESC, "Chnl 0 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:201:STDZMODE_S")
}

record(seq, "MCOR:EXT:201:STDZMODE_S") {
   field(DESC, "Chnl 0 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:201:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:201:CSR_C PP")
   field(LNK2, "MCOR:EXT:201:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:201:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:201:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:201:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:201:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 0")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B0")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:201:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 0")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B0")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:201:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 0")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:201:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:201:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 0")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:201:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:201:ADC_OVERSAMP") {
	field(DESC, "Chnl 0 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:201:FBCK_OVERSAMP") {
	field(DESC, "Chnl 0 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:201:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 0 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:201:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:201:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "0")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:201:SLOT")
}
record(calc, "MCOR:EXT:201:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:201:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:201:NAME") {
	field(DESC, "MCOR Chnl 0 MAD Name")
        field(VAL,  "XCX01")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:201:MAGNET") {
	field(DESC, "MCOR Chnl 0 Magnet Device Name")
        field(VAL,  "XCOR:EXT:368:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:201:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "XCOR:EXT:368:COOLING PP")
}#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:202:ISETPT_S") {
	field(DESC, "Chnl 1 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C1S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:202:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:202:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:202:ISETPT_RBCK") {
	field(DESC, "Chnl 1 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C1S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:202:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:202:IACT") {
#	field(DESC, "Chnl 1 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C1S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:202:IMON") {
	field(DESC, "Chnl 1 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C1S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "YCOR:EXT:762:IMON")
}

record(ai, "MCOR:EXT:202:IRIPL") {
	field(DESC, "Chnl 1 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C1S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:EXT:762:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:202:IFBCK") {
	field(DESC, "Chnl 1 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C1S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:202:IACT") {
	field(DESC, "Chnl 1 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C1S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:EXT:762:IACT")
}
record(ai, "MCOR:EXT:202:IFBCK_RIPL") {
	field(DESC, "Chnl 1 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C1S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:202:IRANGE_DAC_SET") {
	field(DESC, "Chnl 1 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C1S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:202:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:202:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 1 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C1S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:202:IRANGE_ADC_SET") {
	field(DESC, "Chnl 1 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C1S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:202:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:202:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 1 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C1S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:202:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 1 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C1S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:202:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:202:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 1 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C1S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:202:IRAMPRATE") {
	field(DESC, "Chnl 1 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C1S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "YCOR:EXT:762:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:202:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 1 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C1S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:202:NSAMP_AVE_S") {
	field(DESC, "Chnl 1 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C1S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:202:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:202:NSAMP_AVE_R") {
	field(DESC, "Chnl 1 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C1S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:202:CSR_R") {
	field(DESC, "Chnl 1 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C1S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:202:CSR")
}

record(longout, "MCOR:EXT:202:CSR_S") {
	field(DESC, "Chnl 1 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C1S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:202:CSR_C") {
	field(DESC, "Chnl 1 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C1S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:202:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:202:CSR_C PP")
   field(LNK2, "MCOR:EXT:202:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:202:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:202:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:202:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:202:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:202:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:202:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:202:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:202:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:202:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:202:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:202:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:202:TYPE") {
  field(DESC, "Chnl 1 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:202:TYPE_SEQ")
  field(VAL,  "2")
}

record(seq, "MCOR:EXT:202:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:202:CONFIG_SET")
 field(LNK2, "MCOR:EXT:202:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:202:CONFIG_SET")
 field(LNK4, "MCOR:EXT:202:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:202:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:202:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:202:TYPE.RVAL")
  field(INPB, "MCOR:EXT:202:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:202:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:202:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:202:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:202:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:202:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:202:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:202:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:202:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:202:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:202:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:202:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:202:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:202:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:202:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:202:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:202:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:202:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:202:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:202:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:202:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:202:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:202:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:202:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:202:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:202:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:202:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:202:IMON.HOPR")
  field(LNK3, "MCOR:EXT:202:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:202:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:202:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:202:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:202:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:202:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:202:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:202:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:202:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:202:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:202:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:202:IACT.HOPR")
  field(LNK5, "MCOR:EXT:202:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:202:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:202:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "YCOR:EXT:762:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:202:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:202:ISETPT")
  field(INPE, "MCOR:EXT:202:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:202:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:202:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:202:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:202:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:202:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:202:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:202:VSETPT") {
  field(DESC, "Chnl 1 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:202:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:202:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:202:VSETPT_RBCK") {
  field(DESC, "Chnl 1 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:202:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:202:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:202:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:202:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:202:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:202:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:202:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:202:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:202:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:202:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:202:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:202:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:202:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:202:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:202:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:202:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:202:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:202:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:202:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:202:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:202:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:202:CSR_R")
        field(FLNK,  "MCOR:EXT:202:CSR_SEQ")
}

record(seq, "MCOR:EXT:202:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:202:CSR.B5")
        field(DOL2, "MCOR:EXT:202:CSR.B1")
        field(DOL3, "MCOR:EXT:202:CSR.B2")
        field(DOL4, "MCOR:EXT:202:CSR.B3")
        field(DOL5, "MCOR:EXT:202:CSR.B4")
        field(DOL6, "MCOR:EXT:202:CSR.B0")
        field(LNK1, "MCOR:EXT:202:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:202:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:202:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:202:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:202:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:202:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:202:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:202:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:202:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:202:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:202:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:202:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:202:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:202:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:202:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:202:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:202:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:202:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "YCOR:EXT:762:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:202:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:202:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:202:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:202:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:202:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:202:STATE PP")
   field(LNK2,  "MCOR:EXT:202:STATE PP")
   field(LNK3,  "MCOR:EXT:202:STATE PP")
}
record(bo, "MCOR:EXT:202:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:EXT:762:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:202:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:EXT:762:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:202:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:202:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B1 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:202:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:202:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B1 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:202:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:202:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:202:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:202:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:202:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:202:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:202:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:202:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:202:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:202:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:202:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:202:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:202:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:202:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:202:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:202:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "YCOR:EXT:762:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:202:CONFIG_SET") {
  field(DESC, "Chnl 1 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:202:CONFIG_S")
}

record(seq, "MCOR:EXT:202:CONFIG_S") {
   field(DESC, "Chnl 1 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:202:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:202:CSR_C PP")
   field(LNK2, "MCOR:EXT:202:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:202:FBCKMODE_SET") {
  field(DESC, "Chnl 1 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:202:FBCKMODE_S")
}

record(seq, "MCOR:EXT:202:FBCKMODE_S") {
   field(DESC, "Chnl 1 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:202:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:202:CSR_C PP")
   field(LNK2, "MCOR:EXT:202:CSR_S PP")
}

record(mbbo, "MCOR:EXT:202:DACMODE_SET") {
  field(DESC, "Chnl 1 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:202:DACMODE_S")
}

record(seq, "MCOR:EXT:202:DACMODE_S") {
   field(DESC, "Chnl 1 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:202:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:202:CSR_C")
   field(LNK2, "MCOR:EXT:202:CSR_S")
}

record(mbbo, "MCOR:EXT:202:RAMPMODE_SET") {
   field(DESC, "Chnl 1 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:202:RAMPMODE_S")
}

record(seq, "MCOR:EXT:202:RAMPMODE_S") {
   field(DESC,"Chnl 1 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:202:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:202:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:202:CSR_S PP")
   field(LNK3, "MCOR:EXT:202:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:202:STDZMODE_SET") {
  field(DESC, "Chnl 1 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:202:STDZMODE_S")
}

record(seq, "MCOR:EXT:202:STDZMODE_S") {
   field(DESC, "Chnl 1 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:202:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:202:CSR_C PP")
   field(LNK2, "MCOR:EXT:202:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:202:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:202:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:202:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:202:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 1")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B1")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:202:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 1")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B1")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:202:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 1")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:202:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:202:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 1")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:202:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:202:ADC_OVERSAMP") {
	field(DESC, "Chnl 1 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:202:FBCK_OVERSAMP") {
	field(DESC, "Chnl 1 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:202:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 1 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:202:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:202:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "1")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:202:SLOT")
}
record(calc, "MCOR:EXT:202:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:202:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:202:NAME") {
	field(DESC, "MCOR Chnl 1 MAD Name")
        field(VAL,  "YCX02")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:202:MAGNET") {
	field(DESC, "MCOR Chnl 1 Magnet Device Name")
        field(VAL,  "YCOR:EXT:762:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:202:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "YCOR:EXT:762:COOLING PP")
}#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:203:ISETPT_S") {
	field(DESC, "Chnl 2 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C2S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:203:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:203:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:203:ISETPT_RBCK") {
	field(DESC, "Chnl 2 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C2S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:203:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:203:IACT") {
#	field(DESC, "Chnl 2 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C2S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:203:IMON") {
	field(DESC, "Chnl 2 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C2S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "YCOR:DOG:113:IMON")
}

record(ai, "MCOR:EXT:203:IRIPL") {
	field(DESC, "Chnl 2 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C2S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:DOG:113:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:203:IFBCK") {
	field(DESC, "Chnl 2 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C2S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:203:IACT") {
	field(DESC, "Chnl 2 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C2S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:DOG:113:IACT")
}
record(ai, "MCOR:EXT:203:IFBCK_RIPL") {
	field(DESC, "Chnl 2 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C2S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:203:IRANGE_DAC_SET") {
	field(DESC, "Chnl 2 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C2S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:203:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:203:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 2 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C2S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:203:IRANGE_ADC_SET") {
	field(DESC, "Chnl 2 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C2S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:203:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:203:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 2 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C2S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:203:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 2 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C2S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:203:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:203:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 2 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C2S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:203:IRAMPRATE") {
	field(DESC, "Chnl 2 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C2S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "YCOR:DOG:113:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:203:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 2 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C2S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:203:NSAMP_AVE_S") {
	field(DESC, "Chnl 2 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C2S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:203:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:203:NSAMP_AVE_R") {
	field(DESC, "Chnl 2 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C2S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:203:CSR_R") {
	field(DESC, "Chnl 2 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C2S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:203:CSR")
}

record(longout, "MCOR:EXT:203:CSR_S") {
	field(DESC, "Chnl 2 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C2S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:203:CSR_C") {
	field(DESC, "Chnl 2 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C2S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:203:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:203:CSR_C PP")
   field(LNK2, "MCOR:EXT:203:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:203:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:203:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:203:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:203:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:203:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:203:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:203:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:203:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:203:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:203:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:203:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:203:TYPE") {
  field(DESC, "Chnl 2 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:203:TYPE_SEQ")
  field(VAL,  "3")
}

record(seq, "MCOR:EXT:203:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:203:CONFIG_SET")
 field(LNK2, "MCOR:EXT:203:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:203:CONFIG_SET")
 field(LNK4, "MCOR:EXT:203:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:203:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:203:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:203:TYPE.RVAL")
  field(INPB, "MCOR:EXT:203:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:203:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:203:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:203:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:203:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:203:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:203:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:203:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:203:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:203:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:203:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:203:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:203:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:203:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:203:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:203:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:203:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:203:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:203:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:203:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:203:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:203:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:203:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:203:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:203:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:203:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:203:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:203:IMON.HOPR")
  field(LNK3, "MCOR:EXT:203:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:203:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:203:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:203:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:203:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:203:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:203:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:203:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:203:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:203:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:203:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:203:IACT.HOPR")
  field(LNK5, "MCOR:EXT:203:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:203:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:203:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "YCOR:DOG:113:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:203:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:203:ISETPT")
  field(INPE, "MCOR:EXT:203:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:203:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:203:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:203:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:203:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:203:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:203:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:203:VSETPT") {
  field(DESC, "Chnl 2 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:203:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:203:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:203:VSETPT_RBCK") {
  field(DESC, "Chnl 2 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:203:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:203:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:203:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:203:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:203:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:203:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:203:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:203:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:203:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:203:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:203:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:203:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:203:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:203:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:203:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:203:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:203:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:203:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:203:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:203:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:203:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:203:CSR_R")
        field(FLNK,  "MCOR:EXT:203:CSR_SEQ")
}

record(seq, "MCOR:EXT:203:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:203:CSR.B5")
        field(DOL2, "MCOR:EXT:203:CSR.B1")
        field(DOL3, "MCOR:EXT:203:CSR.B2")
        field(DOL4, "MCOR:EXT:203:CSR.B3")
        field(DOL5, "MCOR:EXT:203:CSR.B4")
        field(DOL6, "MCOR:EXT:203:CSR.B0")
        field(LNK1, "MCOR:EXT:203:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:203:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:203:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:203:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:203:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:203:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:203:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:203:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:203:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:203:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:203:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:203:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:203:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:203:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:203:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:203:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:203:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:203:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "YCOR:DOG:113:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:203:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:203:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:203:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:203:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:203:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:203:STATE PP")
   field(LNK2,  "MCOR:EXT:203:STATE PP")
   field(LNK3,  "MCOR:EXT:203:STATE PP")
}
record(bo, "MCOR:EXT:203:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:DOG:113:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:203:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:DOG:113:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:203:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:203:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B2 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:203:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:203:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B2 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:203:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:203:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:203:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:203:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:203:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:203:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:203:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:203:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:203:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:203:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:203:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:203:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:203:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:203:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:203:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:203:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "YCOR:DOG:113:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:203:CONFIG_SET") {
  field(DESC, "Chnl 2 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:203:CONFIG_S")
}

record(seq, "MCOR:EXT:203:CONFIG_S") {
   field(DESC, "Chnl 2 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:203:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:203:CSR_C PP")
   field(LNK2, "MCOR:EXT:203:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:203:FBCKMODE_SET") {
  field(DESC, "Chnl 2 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:203:FBCKMODE_S")
}

record(seq, "MCOR:EXT:203:FBCKMODE_S") {
   field(DESC, "Chnl 2 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:203:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:203:CSR_C PP")
   field(LNK2, "MCOR:EXT:203:CSR_S PP")
}

record(mbbo, "MCOR:EXT:203:DACMODE_SET") {
  field(DESC, "Chnl 2 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:203:DACMODE_S")
}

record(seq, "MCOR:EXT:203:DACMODE_S") {
   field(DESC, "Chnl 2 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:203:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:203:CSR_C")
   field(LNK2, "MCOR:EXT:203:CSR_S")
}

record(mbbo, "MCOR:EXT:203:RAMPMODE_SET") {
   field(DESC, "Chnl 2 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:203:RAMPMODE_S")
}

record(seq, "MCOR:EXT:203:RAMPMODE_S") {
   field(DESC,"Chnl 2 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:203:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:203:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:203:CSR_S PP")
   field(LNK3, "MCOR:EXT:203:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:203:STDZMODE_SET") {
  field(DESC, "Chnl 2 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:203:STDZMODE_S")
}

record(seq, "MCOR:EXT:203:STDZMODE_S") {
   field(DESC, "Chnl 2 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:203:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:203:CSR_C PP")
   field(LNK2, "MCOR:EXT:203:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:203:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:203:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:203:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:203:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 2")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B2")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:203:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 2")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B2")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:203:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 2")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:203:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:203:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 2")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:203:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:203:ADC_OVERSAMP") {
	field(DESC, "Chnl 2 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:203:FBCK_OVERSAMP") {
	field(DESC, "Chnl 2 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:203:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 2 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:203:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:203:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "2")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:203:SLOT")
}
record(calc, "MCOR:EXT:203:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:203:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:203:NAME") {
	field(DESC, "MCOR Chnl 2 MAD Name")
        field(VAL,  "YCDOG0")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:203:MAGNET") {
	field(DESC, "MCOR Chnl 2 Magnet Device Name")
        field(VAL,  "YCOR:DOG:113:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:203:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "YCOR:DOG:113:COOLING PP")
}#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:204:ISETPT_S") {
	field(DESC, "Chnl 3 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C3S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:204:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:204:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:204:ISETPT_RBCK") {
	field(DESC, "Chnl 3 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C3S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:204:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:204:IACT") {
#	field(DESC, "Chnl 3 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C3S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:204:IMON") {
	field(DESC, "Chnl 3 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C3S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "XCOR:DOG:116:IMON")
}

record(ai, "MCOR:EXT:204:IRIPL") {
	field(DESC, "Chnl 3 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C3S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:DOG:116:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:204:IFBCK") {
	field(DESC, "Chnl 3 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C3S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:204:IACT") {
	field(DESC, "Chnl 3 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C3S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:DOG:116:IACT")
}
record(ai, "MCOR:EXT:204:IFBCK_RIPL") {
	field(DESC, "Chnl 3 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C3S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:204:IRANGE_DAC_SET") {
	field(DESC, "Chnl 3 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C3S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:204:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:204:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 3 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C3S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:204:IRANGE_ADC_SET") {
	field(DESC, "Chnl 3 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C3S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:204:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:204:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 3 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C3S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:204:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 3 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C3S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:204:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:204:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 3 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C3S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:204:IRAMPRATE") {
	field(DESC, "Chnl 3 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C3S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "XCOR:DOG:116:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:204:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 3 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C3S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:204:NSAMP_AVE_S") {
	field(DESC, "Chnl 3 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C3S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:204:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:204:NSAMP_AVE_R") {
	field(DESC, "Chnl 3 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C3S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:204:CSR_R") {
	field(DESC, "Chnl 3 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C3S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:204:CSR")
}

record(longout, "MCOR:EXT:204:CSR_S") {
	field(DESC, "Chnl 3 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C3S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:204:CSR_C") {
	field(DESC, "Chnl 3 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C3S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:204:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:204:CSR_C PP")
   field(LNK2, "MCOR:EXT:204:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:204:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:204:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:204:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:204:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:204:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:204:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:204:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:204:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:204:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:204:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:204:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:204:TYPE") {
  field(DESC, "Chnl 3 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:204:TYPE_SEQ")
  field(VAL,  "2")
}

record(seq, "MCOR:EXT:204:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:204:CONFIG_SET")
 field(LNK2, "MCOR:EXT:204:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:204:CONFIG_SET")
 field(LNK4, "MCOR:EXT:204:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:204:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:204:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:204:TYPE.RVAL")
  field(INPB, "MCOR:EXT:204:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:204:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:204:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:204:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:204:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:204:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:204:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:204:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:204:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:204:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:204:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:204:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:204:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:204:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:204:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:204:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:204:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:204:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:204:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:204:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:204:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:204:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:204:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:204:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:204:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:204:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:204:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:204:IMON.HOPR")
  field(LNK3, "MCOR:EXT:204:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:204:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:204:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:204:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:204:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:204:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:204:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:204:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:204:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:204:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:204:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:204:IACT.HOPR")
  field(LNK5, "MCOR:EXT:204:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:204:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:204:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "XCOR:DOG:116:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:204:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:204:ISETPT")
  field(INPE, "MCOR:EXT:204:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:204:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:204:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:204:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:204:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:204:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:204:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:204:VSETPT") {
  field(DESC, "Chnl 3 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:204:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:204:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:204:VSETPT_RBCK") {
  field(DESC, "Chnl 3 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:204:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:204:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:204:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:204:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:204:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:204:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:204:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:204:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:204:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:204:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:204:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:204:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:204:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:204:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:204:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:204:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:204:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:204:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:204:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:204:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:204:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:204:CSR_R")
        field(FLNK,  "MCOR:EXT:204:CSR_SEQ")
}

record(seq, "MCOR:EXT:204:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:204:CSR.B5")
        field(DOL2, "MCOR:EXT:204:CSR.B1")
        field(DOL3, "MCOR:EXT:204:CSR.B2")
        field(DOL4, "MCOR:EXT:204:CSR.B3")
        field(DOL5, "MCOR:EXT:204:CSR.B4")
        field(DOL6, "MCOR:EXT:204:CSR.B0")
        field(LNK1, "MCOR:EXT:204:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:204:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:204:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:204:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:204:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:204:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:204:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:204:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:204:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:204:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:204:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:204:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:204:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:204:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:204:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:204:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:204:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:204:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "XCOR:DOG:116:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:204:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:204:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:204:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:204:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:204:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:204:STATE PP")
   field(LNK2,  "MCOR:EXT:204:STATE PP")
   field(LNK3,  "MCOR:EXT:204:STATE PP")
}
record(bo, "MCOR:EXT:204:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:DOG:116:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:204:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:DOG:116:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:204:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:204:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B3 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:204:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:204:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B3 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:204:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:204:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:204:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:204:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:204:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:204:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:204:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:204:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:204:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:204:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:204:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:204:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:204:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:204:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:204:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:204:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "XCOR:DOG:116:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:204:CONFIG_SET") {
  field(DESC, "Chnl 3 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:204:CONFIG_S")
}

record(seq, "MCOR:EXT:204:CONFIG_S") {
   field(DESC, "Chnl 3 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:204:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:204:CSR_C PP")
   field(LNK2, "MCOR:EXT:204:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:204:FBCKMODE_SET") {
  field(DESC, "Chnl 3 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:204:FBCKMODE_S")
}

record(seq, "MCOR:EXT:204:FBCKMODE_S") {
   field(DESC, "Chnl 3 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:204:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:204:CSR_C PP")
   field(LNK2, "MCOR:EXT:204:CSR_S PP")
}

record(mbbo, "MCOR:EXT:204:DACMODE_SET") {
  field(DESC, "Chnl 3 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:204:DACMODE_S")
}

record(seq, "MCOR:EXT:204:DACMODE_S") {
   field(DESC, "Chnl 3 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:204:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:204:CSR_C")
   field(LNK2, "MCOR:EXT:204:CSR_S")
}

record(mbbo, "MCOR:EXT:204:RAMPMODE_SET") {
   field(DESC, "Chnl 3 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:204:RAMPMODE_S")
}

record(seq, "MCOR:EXT:204:RAMPMODE_S") {
   field(DESC,"Chnl 3 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:204:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:204:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:204:CSR_S PP")
   field(LNK3, "MCOR:EXT:204:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:204:STDZMODE_SET") {
  field(DESC, "Chnl 3 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:204:STDZMODE_S")
}

record(seq, "MCOR:EXT:204:STDZMODE_S") {
   field(DESC, "Chnl 3 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:204:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:204:CSR_C PP")
   field(LNK2, "MCOR:EXT:204:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:204:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:204:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:204:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:204:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 3")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B3")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:204:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 3")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B3")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:204:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 3")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:204:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:204:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 3")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:204:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:204:ADC_OVERSAMP") {
	field(DESC, "Chnl 3 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:204:FBCK_OVERSAMP") {
	field(DESC, "Chnl 3 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:204:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 3 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:204:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:204:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "3")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:204:SLOT")
}
record(calc, "MCOR:EXT:204:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:204:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:204:NAME") {
	field(DESC, "MCOR Chnl 3 MAD Name")
        field(VAL,  "XCDOG1")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:204:MAGNET") {
	field(DESC, "MCOR Chnl 3 Magnet Device Name")
        field(VAL,  "XCOR:DOG:116:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:204:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "XCOR:DOG:116:COOLING PP")
}#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:205:ISETPT_S") {
	field(DESC, "Chnl 4 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C4S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:205:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:205:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:205:ISETPT_RBCK") {
	field(DESC, "Chnl 4 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C4S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:205:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:205:IACT") {
#	field(DESC, "Chnl 4 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C4S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:205:IMON") {
	field(DESC, "Chnl 4 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C4S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "YCOR:DOG:137:IMON")
}

record(ai, "MCOR:EXT:205:IRIPL") {
	field(DESC, "Chnl 4 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C4S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:DOG:137:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:205:IFBCK") {
	field(DESC, "Chnl 4 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C4S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:205:IACT") {
	field(DESC, "Chnl 4 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C4S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:DOG:137:IACT")
}
record(ai, "MCOR:EXT:205:IFBCK_RIPL") {
	field(DESC, "Chnl 4 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C4S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:205:IRANGE_DAC_SET") {
	field(DESC, "Chnl 4 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C4S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:205:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:205:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 4 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C4S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:205:IRANGE_ADC_SET") {
	field(DESC, "Chnl 4 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C4S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:205:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:205:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 4 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C4S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:205:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 4 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C4S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:205:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:205:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 4 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C4S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:205:IRAMPRATE") {
	field(DESC, "Chnl 4 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C4S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "YCOR:DOG:137:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:205:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 4 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C4S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:205:NSAMP_AVE_S") {
	field(DESC, "Chnl 4 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C4S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:205:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:205:NSAMP_AVE_R") {
	field(DESC, "Chnl 4 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C4S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:205:CSR_R") {
	field(DESC, "Chnl 4 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C4S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:205:CSR")
}

record(longout, "MCOR:EXT:205:CSR_S") {
	field(DESC, "Chnl 4 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C4S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:205:CSR_C") {
	field(DESC, "Chnl 4 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C4S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:205:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:205:CSR_C PP")
   field(LNK2, "MCOR:EXT:205:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:205:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:205:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:205:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:205:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:205:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:205:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:205:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:205:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:205:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:205:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:205:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:205:TYPE") {
  field(DESC, "Chnl 4 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:205:TYPE_SEQ")
  field(VAL,  "2")
}

record(seq, "MCOR:EXT:205:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:205:CONFIG_SET")
 field(LNK2, "MCOR:EXT:205:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:205:CONFIG_SET")
 field(LNK4, "MCOR:EXT:205:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:205:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:205:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:205:TYPE.RVAL")
  field(INPB, "MCOR:EXT:205:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:205:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:205:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:205:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:205:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:205:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:205:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:205:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:205:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:205:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:205:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:205:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:205:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:205:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:205:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:205:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:205:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:205:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:205:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:205:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:205:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:205:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:205:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:205:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:205:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:205:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:205:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:205:IMON.HOPR")
  field(LNK3, "MCOR:EXT:205:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:205:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:205:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:205:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:205:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:205:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:205:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:205:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:205:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:205:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:205:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:205:IACT.HOPR")
  field(LNK5, "MCOR:EXT:205:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:205:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:205:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "YCOR:DOG:137:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:205:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:205:ISETPT")
  field(INPE, "MCOR:EXT:205:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:205:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:205:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:205:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:205:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:205:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:205:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:205:VSETPT") {
  field(DESC, "Chnl 4 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:205:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:205:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:205:VSETPT_RBCK") {
  field(DESC, "Chnl 4 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:205:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:205:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:205:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:205:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:205:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:205:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:205:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:205:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:205:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:205:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:205:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:205:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:205:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:205:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:205:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:205:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:205:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:205:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:205:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:205:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:205:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:205:CSR_R")
        field(FLNK,  "MCOR:EXT:205:CSR_SEQ")
}

record(seq, "MCOR:EXT:205:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:205:CSR.B5")
        field(DOL2, "MCOR:EXT:205:CSR.B1")
        field(DOL3, "MCOR:EXT:205:CSR.B2")
        field(DOL4, "MCOR:EXT:205:CSR.B3")
        field(DOL5, "MCOR:EXT:205:CSR.B4")
        field(DOL6, "MCOR:EXT:205:CSR.B0")
        field(LNK1, "MCOR:EXT:205:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:205:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:205:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:205:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:205:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:205:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:205:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:205:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:205:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:205:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:205:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:205:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:205:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:205:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:205:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:205:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:205:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:205:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "YCOR:DOG:137:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:205:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:205:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:205:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:205:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:205:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:205:STATE PP")
   field(LNK2,  "MCOR:EXT:205:STATE PP")
   field(LNK3,  "MCOR:EXT:205:STATE PP")
}
record(bo, "MCOR:EXT:205:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:DOG:137:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:205:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:DOG:137:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:205:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:205:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B4 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:205:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:205:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B4 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:205:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:205:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:205:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:205:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:205:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:205:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:205:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:205:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:205:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:205:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:205:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:205:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:205:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:205:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:205:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:205:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "YCOR:DOG:137:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:205:CONFIG_SET") {
  field(DESC, "Chnl 4 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:205:CONFIG_S")
}

record(seq, "MCOR:EXT:205:CONFIG_S") {
   field(DESC, "Chnl 4 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:205:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:205:CSR_C PP")
   field(LNK2, "MCOR:EXT:205:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:205:FBCKMODE_SET") {
  field(DESC, "Chnl 4 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:205:FBCKMODE_S")
}

record(seq, "MCOR:EXT:205:FBCKMODE_S") {
   field(DESC, "Chnl 4 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:205:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:205:CSR_C PP")
   field(LNK2, "MCOR:EXT:205:CSR_S PP")
}

record(mbbo, "MCOR:EXT:205:DACMODE_SET") {
  field(DESC, "Chnl 4 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:205:DACMODE_S")
}

record(seq, "MCOR:EXT:205:DACMODE_S") {
   field(DESC, "Chnl 4 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:205:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:205:CSR_C")
   field(LNK2, "MCOR:EXT:205:CSR_S")
}

record(mbbo, "MCOR:EXT:205:RAMPMODE_SET") {
   field(DESC, "Chnl 4 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:205:RAMPMODE_S")
}

record(seq, "MCOR:EXT:205:RAMPMODE_S") {
   field(DESC,"Chnl 4 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:205:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:205:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:205:CSR_S PP")
   field(LNK3, "MCOR:EXT:205:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:205:STDZMODE_SET") {
  field(DESC, "Chnl 4 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:205:STDZMODE_S")
}

record(seq, "MCOR:EXT:205:STDZMODE_S") {
   field(DESC, "Chnl 4 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:205:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:205:CSR_C PP")
   field(LNK2, "MCOR:EXT:205:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:205:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:205:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:205:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:205:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 4")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B4")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:205:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 4")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B4")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:205:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 4")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:205:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:205:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 4")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:205:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:205:ADC_OVERSAMP") {
	field(DESC, "Chnl 4 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:205:FBCK_OVERSAMP") {
	field(DESC, "Chnl 4 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:205:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 4 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:205:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:205:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "4")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:205:SLOT")
}
record(calc, "MCOR:EXT:205:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:205:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:205:NAME") {
	field(DESC, "MCOR Chnl 4 MAD Name")
        field(VAL,  "YCDOG2")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:205:MAGNET") {
	field(DESC, "MCOR Chnl 4 Magnet Device Name")
        field(VAL,  "YCOR:DOG:137:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:205:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "YCOR:DOG:137:COOLING PP")
}#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:206:ISETPT_S") {
	field(DESC, "Chnl 5 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C5S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:206:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:206:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:206:ISETPT_RBCK") {
	field(DESC, "Chnl 5 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C5S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:206:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:206:IACT") {
#	field(DESC, "Chnl 5 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C5S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:206:IMON") {
	field(DESC, "Chnl 5 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C5S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "XCOR:DOG:148:IMON")
}

record(ai, "MCOR:EXT:206:IRIPL") {
	field(DESC, "Chnl 5 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C5S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:DOG:148:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:206:IFBCK") {
	field(DESC, "Chnl 5 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C5S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:206:IACT") {
	field(DESC, "Chnl 5 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C5S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:DOG:148:IACT")
}
record(ai, "MCOR:EXT:206:IFBCK_RIPL") {
	field(DESC, "Chnl 5 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C5S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:206:IRANGE_DAC_SET") {
	field(DESC, "Chnl 5 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C5S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:206:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:206:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 5 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C5S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:206:IRANGE_ADC_SET") {
	field(DESC, "Chnl 5 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C5S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:206:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:206:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 5 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C5S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:206:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 5 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C5S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:206:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:206:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 5 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C5S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:206:IRAMPRATE") {
	field(DESC, "Chnl 5 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C5S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "XCOR:DOG:148:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:206:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 5 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C5S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:206:NSAMP_AVE_S") {
	field(DESC, "Chnl 5 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C5S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:206:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:206:NSAMP_AVE_R") {
	field(DESC, "Chnl 5 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C5S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:206:CSR_R") {
	field(DESC, "Chnl 5 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C5S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:206:CSR")
}

record(longout, "MCOR:EXT:206:CSR_S") {
	field(DESC, "Chnl 5 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C5S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:206:CSR_C") {
	field(DESC, "Chnl 5 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C5S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:206:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:206:CSR_C PP")
   field(LNK2, "MCOR:EXT:206:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:206:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:206:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:206:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:206:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:206:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:206:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:206:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:206:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:206:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:206:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:206:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:206:TYPE") {
  field(DESC, "Chnl 5 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:206:TYPE_SEQ")
  field(VAL,  "2")
}

record(seq, "MCOR:EXT:206:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:206:CONFIG_SET")
 field(LNK2, "MCOR:EXT:206:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:206:CONFIG_SET")
 field(LNK4, "MCOR:EXT:206:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:206:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:206:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:206:TYPE.RVAL")
  field(INPB, "MCOR:EXT:206:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:206:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:206:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:206:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:206:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:206:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:206:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:206:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:206:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:206:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:206:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:206:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:206:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:206:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:206:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:206:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:206:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:206:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:206:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:206:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:206:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:206:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:206:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:206:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:206:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:206:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:206:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:206:IMON.HOPR")
  field(LNK3, "MCOR:EXT:206:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:206:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:206:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:206:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:206:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:206:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:206:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:206:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:206:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:206:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:206:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:206:IACT.HOPR")
  field(LNK5, "MCOR:EXT:206:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:206:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:206:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "XCOR:DOG:148:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:206:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:206:ISETPT")
  field(INPE, "MCOR:EXT:206:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:206:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:206:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:206:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:206:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:206:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:206:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:206:VSETPT") {
  field(DESC, "Chnl 5 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:206:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:206:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:206:VSETPT_RBCK") {
  field(DESC, "Chnl 5 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:206:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:206:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:206:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:206:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:206:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:206:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:206:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:206:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:206:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:206:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:206:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:206:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:206:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:206:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:206:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:206:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:206:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:206:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:206:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:206:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:206:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:206:CSR_R")
        field(FLNK,  "MCOR:EXT:206:CSR_SEQ")
}

record(seq, "MCOR:EXT:206:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:206:CSR.B5")
        field(DOL2, "MCOR:EXT:206:CSR.B1")
        field(DOL3, "MCOR:EXT:206:CSR.B2")
        field(DOL4, "MCOR:EXT:206:CSR.B3")
        field(DOL5, "MCOR:EXT:206:CSR.B4")
        field(DOL6, "MCOR:EXT:206:CSR.B0")
        field(LNK1, "MCOR:EXT:206:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:206:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:206:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:206:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:206:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:206:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:206:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:206:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:206:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:206:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:206:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:206:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:206:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:206:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:206:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:206:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:206:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:206:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "XCOR:DOG:148:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:206:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:206:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:206:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:206:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:206:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:206:STATE PP")
   field(LNK2,  "MCOR:EXT:206:STATE PP")
   field(LNK3,  "MCOR:EXT:206:STATE PP")
}
record(bo, "MCOR:EXT:206:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:DOG:148:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:206:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:DOG:148:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:206:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:206:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B5 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:206:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:206:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B5 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:206:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:206:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:206:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:206:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:206:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:206:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:206:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:206:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:206:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:206:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:206:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:206:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:206:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:206:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:206:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:206:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "XCOR:DOG:148:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:206:CONFIG_SET") {
  field(DESC, "Chnl 5 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:206:CONFIG_S")
}

record(seq, "MCOR:EXT:206:CONFIG_S") {
   field(DESC, "Chnl 5 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:206:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:206:CSR_C PP")
   field(LNK2, "MCOR:EXT:206:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:206:FBCKMODE_SET") {
  field(DESC, "Chnl 5 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:206:FBCKMODE_S")
}

record(seq, "MCOR:EXT:206:FBCKMODE_S") {
   field(DESC, "Chnl 5 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:206:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:206:CSR_C PP")
   field(LNK2, "MCOR:EXT:206:CSR_S PP")
}

record(mbbo, "MCOR:EXT:206:DACMODE_SET") {
  field(DESC, "Chnl 5 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:206:DACMODE_S")
}

record(seq, "MCOR:EXT:206:DACMODE_S") {
   field(DESC, "Chnl 5 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:206:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:206:CSR_C")
   field(LNK2, "MCOR:EXT:206:CSR_S")
}

record(mbbo, "MCOR:EXT:206:RAMPMODE_SET") {
   field(DESC, "Chnl 5 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:206:RAMPMODE_S")
}

record(seq, "MCOR:EXT:206:RAMPMODE_S") {
   field(DESC,"Chnl 5 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:206:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:206:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:206:CSR_S PP")
   field(LNK3, "MCOR:EXT:206:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:206:STDZMODE_SET") {
  field(DESC, "Chnl 5 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:206:STDZMODE_S")
}

record(seq, "MCOR:EXT:206:STDZMODE_S") {
   field(DESC, "Chnl 5 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:206:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:206:CSR_C PP")
   field(LNK2, "MCOR:EXT:206:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:206:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:206:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:206:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:206:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 5")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B5")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:206:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 5")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B5")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:206:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 5")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:206:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:206:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 5")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:206:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:206:ADC_OVERSAMP") {
	field(DESC, "Chnl 5 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:206:FBCK_OVERSAMP") {
	field(DESC, "Chnl 5 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:206:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 5 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:206:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:206:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "5")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:206:SLOT")
}
record(calc, "MCOR:EXT:206:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:206:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:206:NAME") {
	field(DESC, "MCOR Chnl 5 MAD Name")
        field(VAL,  "XCDOG3")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:206:MAGNET") {
	field(DESC, "MCOR Chnl 5 Magnet Device Name")
        field(VAL,  "XCOR:DOG:148:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:206:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "XCOR:DOG:148:COOLING PP")
}#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:207:ISETPT_S") {
	field(DESC, "Chnl 6 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C6S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:207:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:207:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:207:ISETPT_RBCK") {
	field(DESC, "Chnl 6 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C6S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:207:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:207:IACT") {
#	field(DESC, "Chnl 6 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C6S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:207:IMON") {
	field(DESC, "Chnl 6 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C6S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "YCOR:DOG:163:IMON")
}

record(ai, "MCOR:EXT:207:IRIPL") {
	field(DESC, "Chnl 6 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C6S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:DOG:163:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:207:IFBCK") {
	field(DESC, "Chnl 6 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C6S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:207:IACT") {
	field(DESC, "Chnl 6 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C6S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:DOG:163:IACT")
}
record(ai, "MCOR:EXT:207:IFBCK_RIPL") {
	field(DESC, "Chnl 6 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C6S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:207:IRANGE_DAC_SET") {
	field(DESC, "Chnl 6 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C6S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:207:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:207:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 6 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C6S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:207:IRANGE_ADC_SET") {
	field(DESC, "Chnl 6 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C6S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:207:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:207:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 6 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C6S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:207:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 6 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C6S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:207:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:207:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 6 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C6S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:207:IRAMPRATE") {
	field(DESC, "Chnl 6 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C6S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "YCOR:DOG:163:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:207:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 6 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C6S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:207:NSAMP_AVE_S") {
	field(DESC, "Chnl 6 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C6S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:207:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:207:NSAMP_AVE_R") {
	field(DESC, "Chnl 6 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C6S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:207:CSR_R") {
	field(DESC, "Chnl 6 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C6S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:207:CSR")
}

record(longout, "MCOR:EXT:207:CSR_S") {
	field(DESC, "Chnl 6 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C6S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:207:CSR_C") {
	field(DESC, "Chnl 6 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C6S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:207:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:207:CSR_C PP")
   field(LNK2, "MCOR:EXT:207:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:207:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:207:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:207:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:207:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:207:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:207:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:207:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:207:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:207:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:207:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:207:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:207:TYPE") {
  field(DESC, "Chnl 6 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:207:TYPE_SEQ")
  field(VAL,  "2")
}

record(seq, "MCOR:EXT:207:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:207:CONFIG_SET")
 field(LNK2, "MCOR:EXT:207:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:207:CONFIG_SET")
 field(LNK4, "MCOR:EXT:207:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:207:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:207:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:207:TYPE.RVAL")
  field(INPB, "MCOR:EXT:207:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:207:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:207:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:207:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:207:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:207:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:207:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:207:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:207:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:207:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:207:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:207:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:207:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:207:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:207:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:207:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:207:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:207:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:207:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:207:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:207:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:207:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:207:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:207:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:207:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:207:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:207:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:207:IMON.HOPR")
  field(LNK3, "MCOR:EXT:207:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:207:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:207:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:207:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:207:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:207:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:207:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:207:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:207:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:207:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:207:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:207:IACT.HOPR")
  field(LNK5, "MCOR:EXT:207:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:207:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:207:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "YCOR:DOG:163:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:207:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:207:ISETPT")
  field(INPE, "MCOR:EXT:207:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:207:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:207:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:207:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:207:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:207:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:207:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:207:VSETPT") {
  field(DESC, "Chnl 6 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:207:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:207:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:207:VSETPT_RBCK") {
  field(DESC, "Chnl 6 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:207:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:207:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:207:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:207:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:207:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:207:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:207:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:207:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:207:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:207:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:207:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:207:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:207:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:207:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:207:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:207:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:207:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:207:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:207:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:207:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:207:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:207:CSR_R")
        field(FLNK,  "MCOR:EXT:207:CSR_SEQ")
}

record(seq, "MCOR:EXT:207:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:207:CSR.B5")
        field(DOL2, "MCOR:EXT:207:CSR.B1")
        field(DOL3, "MCOR:EXT:207:CSR.B2")
        field(DOL4, "MCOR:EXT:207:CSR.B3")
        field(DOL5, "MCOR:EXT:207:CSR.B4")
        field(DOL6, "MCOR:EXT:207:CSR.B0")
        field(LNK1, "MCOR:EXT:207:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:207:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:207:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:207:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:207:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:207:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:207:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:207:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:207:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:207:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:207:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:207:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:207:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:207:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:207:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:207:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:207:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:207:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "YCOR:DOG:163:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:207:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:207:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:207:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:207:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:207:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:207:STATE PP")
   field(LNK2,  "MCOR:EXT:207:STATE PP")
   field(LNK3,  "MCOR:EXT:207:STATE PP")
}
record(bo, "MCOR:EXT:207:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:DOG:163:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:207:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:DOG:163:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:207:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:207:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B6 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:207:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:207:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B6 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:207:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:207:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:207:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:207:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:207:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:207:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:207:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:207:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:207:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:207:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:207:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:207:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:207:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:207:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:207:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:207:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "YCOR:DOG:163:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:207:CONFIG_SET") {
  field(DESC, "Chnl 6 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:207:CONFIG_S")
}

record(seq, "MCOR:EXT:207:CONFIG_S") {
   field(DESC, "Chnl 6 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:207:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:207:CSR_C PP")
   field(LNK2, "MCOR:EXT:207:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:207:FBCKMODE_SET") {
  field(DESC, "Chnl 6 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:207:FBCKMODE_S")
}

record(seq, "MCOR:EXT:207:FBCKMODE_S") {
   field(DESC, "Chnl 6 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:207:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:207:CSR_C PP")
   field(LNK2, "MCOR:EXT:207:CSR_S PP")
}

record(mbbo, "MCOR:EXT:207:DACMODE_SET") {
  field(DESC, "Chnl 6 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:207:DACMODE_S")
}

record(seq, "MCOR:EXT:207:DACMODE_S") {
   field(DESC, "Chnl 6 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:207:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:207:CSR_C")
   field(LNK2, "MCOR:EXT:207:CSR_S")
}

record(mbbo, "MCOR:EXT:207:RAMPMODE_SET") {
   field(DESC, "Chnl 6 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:207:RAMPMODE_S")
}

record(seq, "MCOR:EXT:207:RAMPMODE_S") {
   field(DESC,"Chnl 6 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:207:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:207:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:207:CSR_S PP")
   field(LNK3, "MCOR:EXT:207:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:207:STDZMODE_SET") {
  field(DESC, "Chnl 6 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:207:STDZMODE_S")
}

record(seq, "MCOR:EXT:207:STDZMODE_S") {
   field(DESC, "Chnl 6 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:207:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:207:CSR_C PP")
   field(LNK2, "MCOR:EXT:207:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:207:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:207:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:207:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:207:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 6")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B6")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:207:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 6")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B6")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:207:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 6")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:207:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:207:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 6")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:207:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:207:ADC_OVERSAMP") {
	field(DESC, "Chnl 6 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:207:FBCK_OVERSAMP") {
	field(DESC, "Chnl 6 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:207:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 6 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:207:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:207:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "6")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:207:SLOT")
}
record(calc, "MCOR:EXT:207:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:207:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:207:NAME") {
	field(DESC, "MCOR Chnl 6 MAD Name")
        field(VAL,  "YCDOG4")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:207:MAGNET") {
	field(DESC, "MCOR Chnl 6 Magnet Device Name")
        field(VAL,  "YCOR:DOG:163:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:207:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "YCOR:DOG:163:COOLING PP")
}#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:208:ISETPT_S") {
	field(DESC, "Chnl 7 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C7S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:208:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:208:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:208:ISETPT_RBCK") {
	field(DESC, "Chnl 7 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C7S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:208:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:208:IACT") {
#	field(DESC, "Chnl 7 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C7S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:208:IMON") {
	field(DESC, "Chnl 7 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C7S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "XCOR:DOG:178:IMON")
}

record(ai, "MCOR:EXT:208:IRIPL") {
	field(DESC, "Chnl 7 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C7S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:DOG:178:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:208:IFBCK") {
	field(DESC, "Chnl 7 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C7S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:208:IACT") {
	field(DESC, "Chnl 7 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C7S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:DOG:178:IACT")
}
record(ai, "MCOR:EXT:208:IFBCK_RIPL") {
	field(DESC, "Chnl 7 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C7S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:208:IRANGE_DAC_SET") {
	field(DESC, "Chnl 7 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C7S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:208:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:208:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 7 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C7S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:208:IRANGE_ADC_SET") {
	field(DESC, "Chnl 7 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C7S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:208:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:208:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 7 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C7S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:208:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 7 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C7S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:208:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:208:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 7 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C7S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:208:IRAMPRATE") {
	field(DESC, "Chnl 7 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C7S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "XCOR:DOG:178:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:208:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 7 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C7S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:208:NSAMP_AVE_S") {
	field(DESC, "Chnl 7 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C7S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:208:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:208:NSAMP_AVE_R") {
	field(DESC, "Chnl 7 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C7S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:208:CSR_R") {
	field(DESC, "Chnl 7 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C7S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:208:CSR")
}

record(longout, "MCOR:EXT:208:CSR_S") {
	field(DESC, "Chnl 7 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C7S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:208:CSR_C") {
	field(DESC, "Chnl 7 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C7S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:208:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:208:CSR_C PP")
   field(LNK2, "MCOR:EXT:208:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:208:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:208:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:208:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:208:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:208:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:208:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:208:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:208:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:208:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:208:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:208:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:208:TYPE") {
  field(DESC, "Chnl 7 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:208:TYPE_SEQ")
  field(VAL,  "2")
}

record(seq, "MCOR:EXT:208:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:208:CONFIG_SET")
 field(LNK2, "MCOR:EXT:208:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:208:CONFIG_SET")
 field(LNK4, "MCOR:EXT:208:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:208:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:208:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:208:TYPE.RVAL")
  field(INPB, "MCOR:EXT:208:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:208:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:208:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:208:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:208:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:208:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:208:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:208:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:208:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:208:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:208:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:208:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:208:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:208:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:208:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:208:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:208:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:208:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:208:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:208:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:208:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:208:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:208:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:208:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:208:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:208:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:208:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:208:IMON.HOPR")
  field(LNK3, "MCOR:EXT:208:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:208:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:208:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:208:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:208:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:208:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:208:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:208:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:208:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:208:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:208:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:208:IACT.HOPR")
  field(LNK5, "MCOR:EXT:208:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:208:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:208:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "XCOR:DOG:178:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:208:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:208:ISETPT")
  field(INPE, "MCOR:EXT:208:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:208:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:208:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:208:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:208:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:208:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:208:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:208:VSETPT") {
  field(DESC, "Chnl 7 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:208:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:208:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:208:VSETPT_RBCK") {
  field(DESC, "Chnl 7 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:208:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:208:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:208:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:208:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:208:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:208:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:208:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:208:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:208:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:208:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:208:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:208:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:208:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:208:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:208:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:208:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:208:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:208:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:208:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:208:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:208:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:208:CSR_R")
        field(FLNK,  "MCOR:EXT:208:CSR_SEQ")
}

record(seq, "MCOR:EXT:208:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:208:CSR.B5")
        field(DOL2, "MCOR:EXT:208:CSR.B1")
        field(DOL3, "MCOR:EXT:208:CSR.B2")
        field(DOL4, "MCOR:EXT:208:CSR.B3")
        field(DOL5, "MCOR:EXT:208:CSR.B4")
        field(DOL6, "MCOR:EXT:208:CSR.B0")
        field(LNK1, "MCOR:EXT:208:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:208:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:208:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:208:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:208:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:208:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:208:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:208:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:208:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:208:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:208:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:208:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:208:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:208:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:208:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:208:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:208:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:208:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "XCOR:DOG:178:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:208:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:208:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:208:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:208:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:208:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:208:STATE PP")
   field(LNK2,  "MCOR:EXT:208:STATE PP")
   field(LNK3,  "MCOR:EXT:208:STATE PP")
}
record(bo, "MCOR:EXT:208:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:DOG:178:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:208:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:DOG:178:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:208:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:208:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B7 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:208:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:208:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B7 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:208:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:208:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:208:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:208:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:208:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:208:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:208:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:208:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:208:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:208:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:208:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:208:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:208:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:208:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:208:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:208:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "XCOR:DOG:178:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:208:CONFIG_SET") {
  field(DESC, "Chnl 7 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:208:CONFIG_S")
}

record(seq, "MCOR:EXT:208:CONFIG_S") {
   field(DESC, "Chnl 7 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:208:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:208:CSR_C PP")
   field(LNK2, "MCOR:EXT:208:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:208:FBCKMODE_SET") {
  field(DESC, "Chnl 7 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:208:FBCKMODE_S")
}

record(seq, "MCOR:EXT:208:FBCKMODE_S") {
   field(DESC, "Chnl 7 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:208:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:208:CSR_C PP")
   field(LNK2, "MCOR:EXT:208:CSR_S PP")
}

record(mbbo, "MCOR:EXT:208:DACMODE_SET") {
  field(DESC, "Chnl 7 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:208:DACMODE_S")
}

record(seq, "MCOR:EXT:208:DACMODE_S") {
   field(DESC, "Chnl 7 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:208:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:208:CSR_C")
   field(LNK2, "MCOR:EXT:208:CSR_S")
}

record(mbbo, "MCOR:EXT:208:RAMPMODE_SET") {
   field(DESC, "Chnl 7 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:208:RAMPMODE_S")
}

record(seq, "MCOR:EXT:208:RAMPMODE_S") {
   field(DESC,"Chnl 7 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:208:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:208:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:208:CSR_S PP")
   field(LNK3, "MCOR:EXT:208:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:208:STDZMODE_SET") {
  field(DESC, "Chnl 7 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:208:STDZMODE_S")
}

record(seq, "MCOR:EXT:208:STDZMODE_S") {
   field(DESC, "Chnl 7 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:208:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:208:CSR_C PP")
   field(LNK2, "MCOR:EXT:208:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:208:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:208:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:208:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:208:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 7")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B7")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:208:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 7")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B7")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:208:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 7")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:208:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:208:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 7")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:208:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:208:ADC_OVERSAMP") {
	field(DESC, "Chnl 7 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:208:FBCK_OVERSAMP") {
	field(DESC, "Chnl 7 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:208:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 7 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:208:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:208:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "7")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:208:SLOT")
}
record(calc, "MCOR:EXT:208:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:208:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:208:NAME") {
	field(DESC, "MCOR Chnl 7 MAD Name")
        field(VAL,  "XCDOG5")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:208:MAGNET") {
	field(DESC, "MCOR Chnl 7 Magnet Device Name")
        field(VAL,  "XCOR:DOG:178:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:208:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "XCOR:DOG:178:COOLING PP")
}#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:209:ISETPT_S") {
	field(DESC, "Chnl 8 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C8S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:209:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:209:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:209:ISETPT_RBCK") {
	field(DESC, "Chnl 8 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C8S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:209:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:209:IACT") {
#	field(DESC, "Chnl 8 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C8S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:209:IMON") {
	field(DESC, "Chnl 8 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C8S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "YCOR:DOG:193:IMON")
}

record(ai, "MCOR:EXT:209:IRIPL") {
	field(DESC, "Chnl 8 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C8S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:DOG:193:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:209:IFBCK") {
	field(DESC, "Chnl 8 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C8S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:209:IACT") {
	field(DESC, "Chnl 8 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C8S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:DOG:193:IACT")
}
record(ai, "MCOR:EXT:209:IFBCK_RIPL") {
	field(DESC, "Chnl 8 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C8S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:209:IRANGE_DAC_SET") {
	field(DESC, "Chnl 8 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C8S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:209:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:209:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 8 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C8S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:209:IRANGE_ADC_SET") {
	field(DESC, "Chnl 8 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C8S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:209:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:209:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 8 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C8S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:209:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 8 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C8S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:209:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:209:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 8 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C8S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:209:IRAMPRATE") {
	field(DESC, "Chnl 8 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C8S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "YCOR:DOG:193:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:209:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 8 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C8S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:209:NSAMP_AVE_S") {
	field(DESC, "Chnl 8 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C8S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:209:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:209:NSAMP_AVE_R") {
	field(DESC, "Chnl 8 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C8S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:209:CSR_R") {
	field(DESC, "Chnl 8 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C8S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:209:CSR")
}

record(longout, "MCOR:EXT:209:CSR_S") {
	field(DESC, "Chnl 8 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C8S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:209:CSR_C") {
	field(DESC, "Chnl 8 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C8S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:209:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:209:CSR_C PP")
   field(LNK2, "MCOR:EXT:209:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:209:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:209:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:209:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:209:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:209:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:209:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:209:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:209:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:209:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:209:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:209:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:209:TYPE") {
  field(DESC, "Chnl 8 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:209:TYPE_SEQ")
  field(VAL,  "2")
}

record(seq, "MCOR:EXT:209:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:209:CONFIG_SET")
 field(LNK2, "MCOR:EXT:209:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:209:CONFIG_SET")
 field(LNK4, "MCOR:EXT:209:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:209:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:209:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:209:TYPE.RVAL")
  field(INPB, "MCOR:EXT:209:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:209:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:209:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:209:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:209:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:209:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:209:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:209:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:209:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:209:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:209:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:209:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:209:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:209:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:209:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:209:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:209:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:209:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:209:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:209:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:209:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:209:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:209:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:209:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:209:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:209:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:209:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:209:IMON.HOPR")
  field(LNK3, "MCOR:EXT:209:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:209:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:209:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:209:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:209:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:209:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:209:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:209:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:209:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:209:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:209:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:209:IACT.HOPR")
  field(LNK5, "MCOR:EXT:209:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:209:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:209:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "YCOR:DOG:193:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:209:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:209:ISETPT")
  field(INPE, "MCOR:EXT:209:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:209:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:209:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:209:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:209:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:209:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:209:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:209:VSETPT") {
  field(DESC, "Chnl 8 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:209:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:209:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:209:VSETPT_RBCK") {
  field(DESC, "Chnl 8 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:209:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:209:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:209:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:209:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:209:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:209:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:209:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:209:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:209:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:209:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:209:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:209:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:209:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:209:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:209:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:209:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:209:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:209:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:209:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:209:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:209:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:209:CSR_R")
        field(FLNK,  "MCOR:EXT:209:CSR_SEQ")
}

record(seq, "MCOR:EXT:209:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:209:CSR.B5")
        field(DOL2, "MCOR:EXT:209:CSR.B1")
        field(DOL3, "MCOR:EXT:209:CSR.B2")
        field(DOL4, "MCOR:EXT:209:CSR.B3")
        field(DOL5, "MCOR:EXT:209:CSR.B4")
        field(DOL6, "MCOR:EXT:209:CSR.B0")
        field(LNK1, "MCOR:EXT:209:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:209:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:209:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:209:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:209:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:209:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:209:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:209:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:209:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:209:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:209:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:209:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:209:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:209:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:209:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:209:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:209:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:209:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "YCOR:DOG:193:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:209:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:209:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:209:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:209:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:209:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:209:STATE PP")
   field(LNK2,  "MCOR:EXT:209:STATE PP")
   field(LNK3,  "MCOR:EXT:209:STATE PP")
}
record(bo, "MCOR:EXT:209:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:DOG:193:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:209:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:DOG:193:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:209:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:209:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B8 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:209:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:209:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B8 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:209:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:209:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:209:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:209:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:209:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:209:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:209:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:209:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:209:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:209:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:209:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:209:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:209:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:209:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:209:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:209:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "YCOR:DOG:193:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:209:CONFIG_SET") {
  field(DESC, "Chnl 8 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:209:CONFIG_S")
}

record(seq, "MCOR:EXT:209:CONFIG_S") {
   field(DESC, "Chnl 8 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:209:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:209:CSR_C PP")
   field(LNK2, "MCOR:EXT:209:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:209:FBCKMODE_SET") {
  field(DESC, "Chnl 8 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:209:FBCKMODE_S")
}

record(seq, "MCOR:EXT:209:FBCKMODE_S") {
   field(DESC, "Chnl 8 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:209:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:209:CSR_C PP")
   field(LNK2, "MCOR:EXT:209:CSR_S PP")
}

record(mbbo, "MCOR:EXT:209:DACMODE_SET") {
  field(DESC, "Chnl 8 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:209:DACMODE_S")
}

record(seq, "MCOR:EXT:209:DACMODE_S") {
   field(DESC, "Chnl 8 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:209:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:209:CSR_C")
   field(LNK2, "MCOR:EXT:209:CSR_S")
}

record(mbbo, "MCOR:EXT:209:RAMPMODE_SET") {
   field(DESC, "Chnl 8 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:209:RAMPMODE_S")
}

record(seq, "MCOR:EXT:209:RAMPMODE_S") {
   field(DESC,"Chnl 8 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:209:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:209:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:209:CSR_S PP")
   field(LNK3, "MCOR:EXT:209:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:209:STDZMODE_SET") {
  field(DESC, "Chnl 8 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:209:STDZMODE_S")
}

record(seq, "MCOR:EXT:209:STDZMODE_S") {
   field(DESC, "Chnl 8 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:209:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:209:CSR_C PP")
   field(LNK2, "MCOR:EXT:209:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:209:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:209:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:209:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:209:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 8")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:209:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 8")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:209:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 8")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:209:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:209:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 8")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:209:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:209:ADC_OVERSAMP") {
	field(DESC, "Chnl 8 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:209:FBCK_OVERSAMP") {
	field(DESC, "Chnl 8 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:209:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 8 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:209:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:209:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "8")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:209:SLOT")
}
record(calc, "MCOR:EXT:209:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:209:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:209:NAME") {
	field(DESC, "MCOR Chnl 8 MAD Name")
        field(VAL,  "YCDOG6")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:209:MAGNET") {
	field(DESC, "MCOR Chnl 8 Magnet Device Name")
        field(VAL,  "YCOR:DOG:193:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:209:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "YCOR:DOG:193:COOLING PP")
}#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:210:ISETPT_S") {
	field(DESC, "Chnl 9 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C9S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:210:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:210:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:210:ISETPT_RBCK") {
	field(DESC, "Chnl 9 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C9S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:210:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:210:IACT") {
#	field(DESC, "Chnl 9 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C9S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:210:IMON") {
	field(DESC, "Chnl 9 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C9S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "XCOR:DOG:212:IMON")
}

record(ai, "MCOR:EXT:210:IRIPL") {
	field(DESC, "Chnl 9 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C9S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:DOG:212:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:210:IFBCK") {
	field(DESC, "Chnl 9 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C9S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:210:IACT") {
	field(DESC, "Chnl 9 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C9S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:DOG:212:IACT")
}
record(ai, "MCOR:EXT:210:IFBCK_RIPL") {
	field(DESC, "Chnl 9 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C9S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:210:IRANGE_DAC_SET") {
	field(DESC, "Chnl 9 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C9S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:210:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:210:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 9 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C9S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:210:IRANGE_ADC_SET") {
	field(DESC, "Chnl 9 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C9S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:210:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:210:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 9 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C9S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:210:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 9 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C9S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:210:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:210:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 9 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C9S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:210:IRAMPRATE") {
	field(DESC, "Chnl 9 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C9S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "XCOR:DOG:212:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:210:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 9 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C9S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:210:NSAMP_AVE_S") {
	field(DESC, "Chnl 9 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C9S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:210:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:210:NSAMP_AVE_R") {
	field(DESC, "Chnl 9 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C9S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:210:CSR_R") {
	field(DESC, "Chnl 9 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C9S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:210:CSR")
}

record(longout, "MCOR:EXT:210:CSR_S") {
	field(DESC, "Chnl 9 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C9S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:210:CSR_C") {
	field(DESC, "Chnl 9 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C9S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:210:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:210:CSR_C PP")
   field(LNK2, "MCOR:EXT:210:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:210:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:210:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:210:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:210:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:210:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:210:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:210:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:210:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:210:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:210:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:210:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:210:TYPE") {
  field(DESC, "Chnl 9 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:210:TYPE_SEQ")
  field(VAL,  "2")
}

record(seq, "MCOR:EXT:210:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:210:CONFIG_SET")
 field(LNK2, "MCOR:EXT:210:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:210:CONFIG_SET")
 field(LNK4, "MCOR:EXT:210:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:210:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:210:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:210:TYPE.RVAL")
  field(INPB, "MCOR:EXT:210:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:210:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:210:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:210:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:210:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:210:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:210:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:210:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:210:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:210:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:210:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:210:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:210:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:210:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:210:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:210:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:210:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:210:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:210:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:210:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:210:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:210:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:210:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:210:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:210:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:210:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:210:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:210:IMON.HOPR")
  field(LNK3, "MCOR:EXT:210:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:210:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:210:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:210:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:210:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:210:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:210:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:210:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:210:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:210:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:210:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:210:IACT.HOPR")
  field(LNK5, "MCOR:EXT:210:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:210:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:210:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "XCOR:DOG:212:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:210:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:210:ISETPT")
  field(INPE, "MCOR:EXT:210:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:210:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:210:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:210:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:210:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:210:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:210:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:210:VSETPT") {
  field(DESC, "Chnl 9 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:210:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:210:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:210:VSETPT_RBCK") {
  field(DESC, "Chnl 9 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:210:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:210:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:210:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:210:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:210:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:210:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:210:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:210:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:210:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:210:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:210:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:210:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:210:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:210:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:210:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:210:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:210:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:210:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:210:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:210:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:210:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:210:CSR_R")
        field(FLNK,  "MCOR:EXT:210:CSR_SEQ")
}

record(seq, "MCOR:EXT:210:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:210:CSR.B5")
        field(DOL2, "MCOR:EXT:210:CSR.B1")
        field(DOL3, "MCOR:EXT:210:CSR.B2")
        field(DOL4, "MCOR:EXT:210:CSR.B3")
        field(DOL5, "MCOR:EXT:210:CSR.B4")
        field(DOL6, "MCOR:EXT:210:CSR.B0")
        field(LNK1, "MCOR:EXT:210:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:210:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:210:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:210:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:210:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:210:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:210:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:210:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:210:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:210:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:210:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:210:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:210:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:210:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:210:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:210:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:210:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:210:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "XCOR:DOG:212:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:210:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:210:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:210:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:210:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:210:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:210:STATE PP")
   field(LNK2,  "MCOR:EXT:210:STATE PP")
   field(LNK3,  "MCOR:EXT:210:STATE PP")
}
record(bo, "MCOR:EXT:210:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:DOG:212:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:210:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:DOG:212:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:210:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:210:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B9 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:210:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:210:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B9 NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:210:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:210:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:210:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:210:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:210:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:210:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:210:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:210:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:210:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:210:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:210:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:210:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:210:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:210:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:210:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:210:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "XCOR:DOG:212:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:210:CONFIG_SET") {
  field(DESC, "Chnl 9 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:210:CONFIG_S")
}

record(seq, "MCOR:EXT:210:CONFIG_S") {
   field(DESC, "Chnl 9 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:210:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:210:CSR_C PP")
   field(LNK2, "MCOR:EXT:210:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:210:FBCKMODE_SET") {
  field(DESC, "Chnl 9 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:210:FBCKMODE_S")
}

record(seq, "MCOR:EXT:210:FBCKMODE_S") {
   field(DESC, "Chnl 9 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:210:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:210:CSR_C PP")
   field(LNK2, "MCOR:EXT:210:CSR_S PP")
}

record(mbbo, "MCOR:EXT:210:DACMODE_SET") {
  field(DESC, "Chnl 9 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:210:DACMODE_S")
}

record(seq, "MCOR:EXT:210:DACMODE_S") {
   field(DESC, "Chnl 9 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:210:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:210:CSR_C")
   field(LNK2, "MCOR:EXT:210:CSR_S")
}

record(mbbo, "MCOR:EXT:210:RAMPMODE_SET") {
   field(DESC, "Chnl 9 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:210:RAMPMODE_S")
}

record(seq, "MCOR:EXT:210:RAMPMODE_S") {
   field(DESC,"Chnl 9 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:210:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:210:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:210:CSR_S PP")
   field(LNK3, "MCOR:EXT:210:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:210:STDZMODE_SET") {
  field(DESC, "Chnl 9 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:210:STDZMODE_S")
}

record(seq, "MCOR:EXT:210:STDZMODE_S") {
   field(DESC, "Chnl 9 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:210:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:210:CSR_C PP")
   field(LNK2, "MCOR:EXT:210:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:210:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:210:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:210:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:210:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 9")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.B9")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:210:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 9")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B9")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:210:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 9")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:210:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:210:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 9")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:210:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:210:ADC_OVERSAMP") {
	field(DESC, "Chnl 9 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:210:FBCK_OVERSAMP") {
	field(DESC, "Chnl 9 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:210:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 9 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:210:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:210:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "9")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:210:SLOT")
}
record(calc, "MCOR:EXT:210:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:210:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:210:NAME") {
	field(DESC, "MCOR Chnl 9 MAD Name")
        field(VAL,  "XCDOG7")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:210:MAGNET") {
	field(DESC, "MCOR Chnl 9 Magnet Device Name")
        field(VAL,  "XCOR:DOG:212:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:210:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "XCOR:DOG:212:COOLING PP")
}#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:211:ISETPT_S") {
	field(DESC, "Chnl 10 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C10S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:211:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:211:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:211:ISETPT_RBCK") {
	field(DESC, "Chnl 10 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C10S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:211:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:211:IACT") {
#	field(DESC, "Chnl 10 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C10S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:211:IMON") {
	field(DESC, "Chnl 10 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C10S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "YCOR:DOG:227:IMON")
}

record(ai, "MCOR:EXT:211:IRIPL") {
	field(DESC, "Chnl 10 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C10S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:DOG:227:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:211:IFBCK") {
	field(DESC, "Chnl 10 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C10S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:211:IACT") {
	field(DESC, "Chnl 10 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C10S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:DOG:227:IACT")
}
record(ai, "MCOR:EXT:211:IFBCK_RIPL") {
	field(DESC, "Chnl 10 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C10S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:211:IRANGE_DAC_SET") {
	field(DESC, "Chnl 10 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C10S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:211:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:211:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 10 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C10S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:211:IRANGE_ADC_SET") {
	field(DESC, "Chnl 10 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C10S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:211:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:211:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 10 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C10S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:211:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 10 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C10S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:211:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:211:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 10 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C10S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:211:IRAMPRATE") {
	field(DESC, "Chnl 10 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C10S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "YCOR:DOG:227:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:211:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 10 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C10S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:211:NSAMP_AVE_S") {
	field(DESC, "Chnl 10 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C10S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:211:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:211:NSAMP_AVE_R") {
	field(DESC, "Chnl 10 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C10S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:211:CSR_R") {
	field(DESC, "Chnl 10 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C10S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:211:CSR")
}

record(longout, "MCOR:EXT:211:CSR_S") {
	field(DESC, "Chnl 10 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C10S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:211:CSR_C") {
	field(DESC, "Chnl 10 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C10S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:211:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:211:CSR_C PP")
   field(LNK2, "MCOR:EXT:211:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:211:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:211:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:211:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:211:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:211:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:211:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:211:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:211:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:211:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:211:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:211:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:211:TYPE") {
  field(DESC, "Chnl 10 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:211:TYPE_SEQ")
  field(VAL,  "2")
}

record(seq, "MCOR:EXT:211:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:211:CONFIG_SET")
 field(LNK2, "MCOR:EXT:211:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:211:CONFIG_SET")
 field(LNK4, "MCOR:EXT:211:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:211:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:211:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:211:TYPE.RVAL")
  field(INPB, "MCOR:EXT:211:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:211:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:211:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:211:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:211:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:211:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:211:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:211:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:211:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:211:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:211:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:211:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:211:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:211:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:211:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:211:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:211:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:211:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:211:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:211:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:211:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:211:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:211:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:211:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:211:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:211:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:211:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:211:IMON.HOPR")
  field(LNK3, "MCOR:EXT:211:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:211:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:211:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:211:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:211:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:211:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:211:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:211:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:211:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:211:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:211:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:211:IACT.HOPR")
  field(LNK5, "MCOR:EXT:211:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:211:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:211:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "YCOR:DOG:227:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:211:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:211:ISETPT")
  field(INPE, "MCOR:EXT:211:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:211:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:211:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:211:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:211:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:211:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:211:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:211:VSETPT") {
  field(DESC, "Chnl 10 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:211:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:211:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:211:VSETPT_RBCK") {
  field(DESC, "Chnl 10 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:211:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:211:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:211:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:211:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:211:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:211:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:211:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:211:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:211:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:211:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:211:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:211:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:211:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:211:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:211:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:211:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:211:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:211:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:211:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:211:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:211:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:211:CSR_R")
        field(FLNK,  "MCOR:EXT:211:CSR_SEQ")
}

record(seq, "MCOR:EXT:211:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:211:CSR.B5")
        field(DOL2, "MCOR:EXT:211:CSR.B1")
        field(DOL3, "MCOR:EXT:211:CSR.B2")
        field(DOL4, "MCOR:EXT:211:CSR.B3")
        field(DOL5, "MCOR:EXT:211:CSR.B4")
        field(DOL6, "MCOR:EXT:211:CSR.B0")
        field(LNK1, "MCOR:EXT:211:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:211:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:211:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:211:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:211:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:211:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:211:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:211:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:211:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:211:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:211:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:211:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:211:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:211:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:211:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:211:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:211:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:211:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "YCOR:DOG:227:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:211:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:211:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:211:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:211:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:211:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:211:STATE PP")
   field(LNK2,  "MCOR:EXT:211:STATE PP")
   field(LNK3,  "MCOR:EXT:211:STATE PP")
}
record(bo, "MCOR:EXT:211:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:DOG:227:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:211:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:DOG:227:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:211:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:211:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.BA NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:211:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:211:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BA NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:211:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:211:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:211:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:211:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:211:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:211:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:211:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:211:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:211:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:211:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:211:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:211:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:211:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:211:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:211:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:211:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "YCOR:DOG:227:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:211:CONFIG_SET") {
  field(DESC, "Chnl 10 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:211:CONFIG_S")
}

record(seq, "MCOR:EXT:211:CONFIG_S") {
   field(DESC, "Chnl 10 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:211:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:211:CSR_C PP")
   field(LNK2, "MCOR:EXT:211:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:211:FBCKMODE_SET") {
  field(DESC, "Chnl 10 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:211:FBCKMODE_S")
}

record(seq, "MCOR:EXT:211:FBCKMODE_S") {
   field(DESC, "Chnl 10 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:211:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:211:CSR_C PP")
   field(LNK2, "MCOR:EXT:211:CSR_S PP")
}

record(mbbo, "MCOR:EXT:211:DACMODE_SET") {
  field(DESC, "Chnl 10 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:211:DACMODE_S")
}

record(seq, "MCOR:EXT:211:DACMODE_S") {
   field(DESC, "Chnl 10 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:211:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:211:CSR_C")
   field(LNK2, "MCOR:EXT:211:CSR_S")
}

record(mbbo, "MCOR:EXT:211:RAMPMODE_SET") {
   field(DESC, "Chnl 10 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:211:RAMPMODE_S")
}

record(seq, "MCOR:EXT:211:RAMPMODE_S") {
   field(DESC,"Chnl 10 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:211:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:211:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:211:CSR_S PP")
   field(LNK3, "MCOR:EXT:211:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:211:STDZMODE_SET") {
  field(DESC, "Chnl 10 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:211:STDZMODE_S")
}

record(seq, "MCOR:EXT:211:STDZMODE_S") {
   field(DESC, "Chnl 10 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:211:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:211:CSR_C PP")
   field(LNK2, "MCOR:EXT:211:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:211:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:211:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:211:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:211:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 10")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.BA")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:211:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 10")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BA")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:211:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 10")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:211:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:211:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 10")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:211:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:211:ADC_OVERSAMP") {
	field(DESC, "Chnl 10 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:211:FBCK_OVERSAMP") {
	field(DESC, "Chnl 10 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:211:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 10 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:211:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:211:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "10")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:211:SLOT")
}
record(calc, "MCOR:EXT:211:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:211:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:211:NAME") {
	field(DESC, "MCOR Chnl 10 MAD Name")
        field(VAL,  "YCDOG8")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:211:MAGNET") {
	field(DESC, "MCOR Chnl 10 Magnet Device Name")
        field(VAL,  "YCOR:DOG:227:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:211:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "YCOR:DOG:227:COOLING PP")
}#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:212:ISETPT_S") {
	field(DESC, "Chnl 11 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C11S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:212:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:212:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:212:ISETPT_RBCK") {
	field(DESC, "Chnl 11 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C11S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:212:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:212:IACT") {
#	field(DESC, "Chnl 11 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C11S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:212:IMON") {
	field(DESC, "Chnl 11 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C11S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "XCOR:DOG:252:IMON")
}

record(ai, "MCOR:EXT:212:IRIPL") {
	field(DESC, "Chnl 11 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C11S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:DOG:252:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:212:IFBCK") {
	field(DESC, "Chnl 11 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C11S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:212:IACT") {
	field(DESC, "Chnl 11 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C11S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:DOG:252:IACT")
}
record(ai, "MCOR:EXT:212:IFBCK_RIPL") {
	field(DESC, "Chnl 11 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C11S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:212:IRANGE_DAC_SET") {
	field(DESC, "Chnl 11 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C11S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:212:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:212:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 11 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C11S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:212:IRANGE_ADC_SET") {
	field(DESC, "Chnl 11 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C11S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:212:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:212:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 11 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C11S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:212:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 11 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C11S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:212:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:212:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 11 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C11S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:212:IRAMPRATE") {
	field(DESC, "Chnl 11 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C11S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "XCOR:DOG:252:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:212:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 11 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C11S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:212:NSAMP_AVE_S") {
	field(DESC, "Chnl 11 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C11S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:212:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:212:NSAMP_AVE_R") {
	field(DESC, "Chnl 11 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C11S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:212:CSR_R") {
	field(DESC, "Chnl 11 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C11S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:212:CSR")
}

record(longout, "MCOR:EXT:212:CSR_S") {
	field(DESC, "Chnl 11 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C11S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:212:CSR_C") {
	field(DESC, "Chnl 11 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C11S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:212:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:212:CSR_C PP")
   field(LNK2, "MCOR:EXT:212:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:212:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:212:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:212:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:212:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:212:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:212:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:212:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:212:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:212:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:212:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:212:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:212:TYPE") {
  field(DESC, "Chnl 11 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:212:TYPE_SEQ")
  field(VAL,  "2")
}

record(seq, "MCOR:EXT:212:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:212:CONFIG_SET")
 field(LNK2, "MCOR:EXT:212:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:212:CONFIG_SET")
 field(LNK4, "MCOR:EXT:212:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:212:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:212:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:212:TYPE.RVAL")
  field(INPB, "MCOR:EXT:212:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:212:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:212:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:212:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:212:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:212:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:212:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:212:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:212:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:212:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:212:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:212:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:212:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:212:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:212:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:212:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:212:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:212:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:212:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:212:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:212:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:212:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:212:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:212:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:212:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:212:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:212:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:212:IMON.HOPR")
  field(LNK3, "MCOR:EXT:212:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:212:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:212:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:212:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:212:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:212:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:212:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:212:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:212:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:212:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:212:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:212:IACT.HOPR")
  field(LNK5, "MCOR:EXT:212:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:212:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:212:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "XCOR:DOG:252:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:212:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:212:ISETPT")
  field(INPE, "MCOR:EXT:212:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:212:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:212:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:212:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:212:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:212:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:212:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:212:VSETPT") {
  field(DESC, "Chnl 11 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:212:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:212:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:212:VSETPT_RBCK") {
  field(DESC, "Chnl 11 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:212:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:212:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:212:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:212:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:212:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:212:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:212:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:212:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:212:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:212:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:212:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:212:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:212:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:212:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:212:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:212:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:212:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:212:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:212:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:212:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:212:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:212:CSR_R")
        field(FLNK,  "MCOR:EXT:212:CSR_SEQ")
}

record(seq, "MCOR:EXT:212:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:212:CSR.B5")
        field(DOL2, "MCOR:EXT:212:CSR.B1")
        field(DOL3, "MCOR:EXT:212:CSR.B2")
        field(DOL4, "MCOR:EXT:212:CSR.B3")
        field(DOL5, "MCOR:EXT:212:CSR.B4")
        field(DOL6, "MCOR:EXT:212:CSR.B0")
        field(LNK1, "MCOR:EXT:212:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:212:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:212:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:212:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:212:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:212:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:212:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:212:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:212:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:212:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:212:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:212:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:212:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:212:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:212:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:212:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:212:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:212:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "XCOR:DOG:252:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:212:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:212:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:212:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:212:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:212:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:212:STATE PP")
   field(LNK2,  "MCOR:EXT:212:STATE PP")
   field(LNK3,  "MCOR:EXT:212:STATE PP")
}
record(bo, "MCOR:EXT:212:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:DOG:252:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:212:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:DOG:252:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:212:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:212:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.BB NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:212:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:212:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BB NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:212:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:212:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:212:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:212:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:212:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:212:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:212:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:212:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:212:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:212:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:212:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:212:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:212:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:212:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:212:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:212:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "XCOR:DOG:252:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:212:CONFIG_SET") {
  field(DESC, "Chnl 11 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:212:CONFIG_S")
}

record(seq, "MCOR:EXT:212:CONFIG_S") {
   field(DESC, "Chnl 11 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:212:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:212:CSR_C PP")
   field(LNK2, "MCOR:EXT:212:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:212:FBCKMODE_SET") {
  field(DESC, "Chnl 11 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:212:FBCKMODE_S")
}

record(seq, "MCOR:EXT:212:FBCKMODE_S") {
   field(DESC, "Chnl 11 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:212:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:212:CSR_C PP")
   field(LNK2, "MCOR:EXT:212:CSR_S PP")
}

record(mbbo, "MCOR:EXT:212:DACMODE_SET") {
  field(DESC, "Chnl 11 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:212:DACMODE_S")
}

record(seq, "MCOR:EXT:212:DACMODE_S") {
   field(DESC, "Chnl 11 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:212:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:212:CSR_C")
   field(LNK2, "MCOR:EXT:212:CSR_S")
}

record(mbbo, "MCOR:EXT:212:RAMPMODE_SET") {
   field(DESC, "Chnl 11 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:212:RAMPMODE_S")
}

record(seq, "MCOR:EXT:212:RAMPMODE_S") {
   field(DESC,"Chnl 11 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:212:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:212:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:212:CSR_S PP")
   field(LNK3, "MCOR:EXT:212:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:212:STDZMODE_SET") {
  field(DESC, "Chnl 11 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:212:STDZMODE_S")
}

record(seq, "MCOR:EXT:212:STDZMODE_S") {
   field(DESC, "Chnl 11 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:212:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:212:CSR_C PP")
   field(LNK2, "MCOR:EXT:212:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:212:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:212:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:212:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:212:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 11")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.BB")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:212:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 11")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BB")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:212:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 11")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:212:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:212:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 11")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:212:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:212:ADC_OVERSAMP") {
	field(DESC, "Chnl 11 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:212:FBCK_OVERSAMP") {
	field(DESC, "Chnl 11 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:212:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 11 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:212:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:212:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "11")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:212:SLOT")
}
record(calc, "MCOR:EXT:212:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:212:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:212:NAME") {
	field(DESC, "MCOR Chnl 11 MAD Name")
        field(VAL,  "XCL1P")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:212:MAGNET") {
	field(DESC, "MCOR Chnl 11 Magnet Device Name")
        field(VAL,  "XCOR:DOG:252:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:212:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "XCOR:DOG:252:COOLING PP")
}#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:213:ISETPT_S") {
	field(DESC, "Chnl 12 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C12S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:213:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:213:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:213:ISETPT_RBCK") {
	field(DESC, "Chnl 12 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C12S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:213:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:213:IACT") {
#	field(DESC, "Chnl 12 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C12S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:213:IMON") {
	field(DESC, "Chnl 12 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C12S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "YCOR:DOG:281:IMON")
}

record(ai, "MCOR:EXT:213:IRIPL") {
	field(DESC, "Chnl 12 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C12S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:DOG:281:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:213:IFBCK") {
	field(DESC, "Chnl 12 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C12S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:213:IACT") {
	field(DESC, "Chnl 12 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C12S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:DOG:281:IACT")
}
record(ai, "MCOR:EXT:213:IFBCK_RIPL") {
	field(DESC, "Chnl 12 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C12S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:213:IRANGE_DAC_SET") {
	field(DESC, "Chnl 12 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C12S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:213:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:213:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 12 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C12S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:213:IRANGE_ADC_SET") {
	field(DESC, "Chnl 12 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C12S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:213:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:213:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 12 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C12S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:213:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 12 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C12S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:213:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:213:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 12 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C12S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:213:IRAMPRATE") {
	field(DESC, "Chnl 12 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C12S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "YCOR:DOG:281:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:213:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 12 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C12S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:213:NSAMP_AVE_S") {
	field(DESC, "Chnl 12 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C12S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:213:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:213:NSAMP_AVE_R") {
	field(DESC, "Chnl 12 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C12S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:213:CSR_R") {
	field(DESC, "Chnl 12 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C12S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:213:CSR")
}

record(longout, "MCOR:EXT:213:CSR_S") {
	field(DESC, "Chnl 12 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C12S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:213:CSR_C") {
	field(DESC, "Chnl 12 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C12S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:213:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:213:CSR_C PP")
   field(LNK2, "MCOR:EXT:213:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:213:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:213:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:213:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:213:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:213:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:213:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:213:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:213:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:213:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:213:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:213:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:213:TYPE") {
  field(DESC, "Chnl 12 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:213:TYPE_SEQ")
  field(VAL,  "1")
}

record(seq, "MCOR:EXT:213:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:213:CONFIG_SET")
 field(LNK2, "MCOR:EXT:213:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:213:CONFIG_SET")
 field(LNK4, "MCOR:EXT:213:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:213:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:213:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:213:TYPE.RVAL")
  field(INPB, "MCOR:EXT:213:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:213:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:213:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:213:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:213:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:213:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:213:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:213:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:213:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:213:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:213:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:213:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:213:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:213:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:213:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:213:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:213:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:213:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:213:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:213:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:213:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:213:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:213:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:213:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:213:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:213:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:213:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:213:IMON.HOPR")
  field(LNK3, "MCOR:EXT:213:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:213:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:213:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:213:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:213:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:213:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:213:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:213:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:213:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:213:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:213:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:213:IACT.HOPR")
  field(LNK5, "MCOR:EXT:213:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:213:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:213:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "YCOR:DOG:281:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:213:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:213:ISETPT")
  field(INPE, "MCOR:EXT:213:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:213:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:213:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:213:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:213:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:213:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:213:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:213:VSETPT") {
  field(DESC, "Chnl 12 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:213:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:213:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:213:VSETPT_RBCK") {
  field(DESC, "Chnl 12 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:213:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:213:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:213:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:213:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:213:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:213:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:213:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:213:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:213:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:213:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:213:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:213:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:213:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:213:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:213:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:213:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:213:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:213:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:213:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:213:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:213:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:213:CSR_R")
        field(FLNK,  "MCOR:EXT:213:CSR_SEQ")
}

record(seq, "MCOR:EXT:213:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:213:CSR.B5")
        field(DOL2, "MCOR:EXT:213:CSR.B1")
        field(DOL3, "MCOR:EXT:213:CSR.B2")
        field(DOL4, "MCOR:EXT:213:CSR.B3")
        field(DOL5, "MCOR:EXT:213:CSR.B4")
        field(DOL6, "MCOR:EXT:213:CSR.B0")
        field(LNK1, "MCOR:EXT:213:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:213:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:213:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:213:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:213:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:213:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:213:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:213:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:213:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:213:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:213:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:213:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:213:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:213:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:213:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:213:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:213:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:213:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "YCOR:DOG:281:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:213:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:213:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:213:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:213:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:213:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:213:STATE PP")
   field(LNK2,  "MCOR:EXT:213:STATE PP")
   field(LNK3,  "MCOR:EXT:213:STATE PP")
}
record(bo, "MCOR:EXT:213:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:DOG:281:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:213:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:DOG:281:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:213:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:213:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.BC NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:213:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:213:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BC NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:213:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:213:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:213:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:213:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:213:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:213:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:213:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:213:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:213:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:213:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:213:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:213:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:213:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:213:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:213:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:213:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "YCOR:DOG:281:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:213:CONFIG_SET") {
  field(DESC, "Chnl 12 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:213:CONFIG_S")
}

record(seq, "MCOR:EXT:213:CONFIG_S") {
   field(DESC, "Chnl 12 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:213:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:213:CSR_C PP")
   field(LNK2, "MCOR:EXT:213:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:213:FBCKMODE_SET") {
  field(DESC, "Chnl 12 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:213:FBCKMODE_S")
}

record(seq, "MCOR:EXT:213:FBCKMODE_S") {
   field(DESC, "Chnl 12 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:213:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:213:CSR_C PP")
   field(LNK2, "MCOR:EXT:213:CSR_S PP")
}

record(mbbo, "MCOR:EXT:213:DACMODE_SET") {
  field(DESC, "Chnl 12 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:213:DACMODE_S")
}

record(seq, "MCOR:EXT:213:DACMODE_S") {
   field(DESC, "Chnl 12 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:213:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:213:CSR_C")
   field(LNK2, "MCOR:EXT:213:CSR_S")
}

record(mbbo, "MCOR:EXT:213:RAMPMODE_SET") {
   field(DESC, "Chnl 12 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:213:RAMPMODE_S")
}

record(seq, "MCOR:EXT:213:RAMPMODE_S") {
   field(DESC,"Chnl 12 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:213:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:213:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:213:CSR_S PP")
   field(LNK3, "MCOR:EXT:213:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:213:STDZMODE_SET") {
  field(DESC, "Chnl 12 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:213:STDZMODE_S")
}

record(seq, "MCOR:EXT:213:STDZMODE_S") {
   field(DESC, "Chnl 12 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:213:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:213:CSR_C PP")
   field(LNK2, "MCOR:EXT:213:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:213:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:213:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:213:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:213:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 12")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.BC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:213:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 12")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:213:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 12")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:213:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:213:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 12")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:213:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:213:ADC_OVERSAMP") {
	field(DESC, "Chnl 12 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:213:FBCK_OVERSAMP") {
	field(DESC, "Chnl 12 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:213:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 12 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:213:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:213:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "12")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:213:SLOT")
}
record(calc, "MCOR:EXT:213:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:213:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:213:NAME") {
	field(DESC, "MCOR Chnl 12 MAD Name")
        field(VAL,  "YCL2P")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:213:MAGNET") {
	field(DESC, "MCOR Chnl 12 Magnet Device Name")
        field(VAL,  "YCOR:DOG:281:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:213:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "YCOR:DOG:281:COOLING PP")
}#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:214:ISETPT_S") {
	field(DESC, "Chnl 13 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C13S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:214:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:214:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:214:ISETPT_RBCK") {
	field(DESC, "Chnl 13 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C13S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:214:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:214:IACT") {
#	field(DESC, "Chnl 13 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C13S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:214:IMON") {
	field(DESC, "Chnl 13 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C13S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "XCOR:DOG:338:IMON")
}

record(ai, "MCOR:EXT:214:IRIPL") {
	field(DESC, "Chnl 13 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C13S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:DOG:338:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:214:IFBCK") {
	field(DESC, "Chnl 13 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C13S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:214:IACT") {
	field(DESC, "Chnl 13 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C13S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:DOG:338:IACT")
}
record(ai, "MCOR:EXT:214:IFBCK_RIPL") {
	field(DESC, "Chnl 13 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C13S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:214:IRANGE_DAC_SET") {
	field(DESC, "Chnl 13 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C13S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:214:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:214:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 13 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C13S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:214:IRANGE_ADC_SET") {
	field(DESC, "Chnl 13 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C13S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:214:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:214:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 13 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C13S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:214:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 13 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C13S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:214:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:214:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 13 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C13S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:214:IRAMPRATE") {
	field(DESC, "Chnl 13 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C13S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "XCOR:DOG:338:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:214:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 13 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C13S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:214:NSAMP_AVE_S") {
	field(DESC, "Chnl 13 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C13S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:214:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:214:NSAMP_AVE_R") {
	field(DESC, "Chnl 13 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C13S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:214:CSR_R") {
	field(DESC, "Chnl 13 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C13S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:214:CSR")
}

record(longout, "MCOR:EXT:214:CSR_S") {
	field(DESC, "Chnl 13 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C13S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:214:CSR_C") {
	field(DESC, "Chnl 13 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C13S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:214:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:214:CSR_C PP")
   field(LNK2, "MCOR:EXT:214:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:214:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:214:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:214:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:214:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:214:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:214:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:214:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:214:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:214:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:214:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:214:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:214:TYPE") {
  field(DESC, "Chnl 13 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:214:TYPE_SEQ")
  field(VAL,  "1")
}

record(seq, "MCOR:EXT:214:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:214:CONFIG_SET")
 field(LNK2, "MCOR:EXT:214:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:214:CONFIG_SET")
 field(LNK4, "MCOR:EXT:214:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:214:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:214:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:214:TYPE.RVAL")
  field(INPB, "MCOR:EXT:214:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:214:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:214:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:214:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:214:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:214:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:214:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:214:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:214:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:214:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:214:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:214:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:214:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:214:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:214:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:214:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:214:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:214:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:214:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:214:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:214:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:214:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:214:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:214:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:214:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:214:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:214:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:214:IMON.HOPR")
  field(LNK3, "MCOR:EXT:214:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:214:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:214:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:214:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:214:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:214:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:214:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:214:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:214:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:214:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:214:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:214:IACT.HOPR")
  field(LNK5, "MCOR:EXT:214:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:214:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:214:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "XCOR:DOG:338:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:214:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:214:ISETPT")
  field(INPE, "MCOR:EXT:214:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:214:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:214:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:214:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:214:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:214:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:214:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:214:VSETPT") {
  field(DESC, "Chnl 13 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:214:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:214:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:214:VSETPT_RBCK") {
  field(DESC, "Chnl 13 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:214:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:214:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:214:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:214:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:214:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:214:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:214:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:214:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:214:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:214:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:214:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:214:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:214:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:214:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:214:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:214:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:214:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:214:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:214:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:214:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:214:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:214:CSR_R")
        field(FLNK,  "MCOR:EXT:214:CSR_SEQ")
}

record(seq, "MCOR:EXT:214:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:214:CSR.B5")
        field(DOL2, "MCOR:EXT:214:CSR.B1")
        field(DOL3, "MCOR:EXT:214:CSR.B2")
        field(DOL4, "MCOR:EXT:214:CSR.B3")
        field(DOL5, "MCOR:EXT:214:CSR.B4")
        field(DOL6, "MCOR:EXT:214:CSR.B0")
        field(LNK1, "MCOR:EXT:214:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:214:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:214:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:214:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:214:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:214:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:214:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:214:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:214:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:214:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:214:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:214:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:214:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:214:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:214:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:214:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:214:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:214:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "XCOR:DOG:338:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:214:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:214:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:214:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:214:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:214:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:214:STATE PP")
   field(LNK2,  "MCOR:EXT:214:STATE PP")
   field(LNK3,  "MCOR:EXT:214:STATE PP")
}
record(bo, "MCOR:EXT:214:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:DOG:338:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:214:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:DOG:338:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:214:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:214:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.BD NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:214:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:214:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BD NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:214:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:214:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:214:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:214:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:214:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:214:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:214:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:214:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:214:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:214:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:214:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:214:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:214:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:214:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:214:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:214:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "XCOR:DOG:338:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:214:CONFIG_SET") {
  field(DESC, "Chnl 13 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:214:CONFIG_S")
}

record(seq, "MCOR:EXT:214:CONFIG_S") {
   field(DESC, "Chnl 13 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:214:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:214:CSR_C PP")
   field(LNK2, "MCOR:EXT:214:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:214:FBCKMODE_SET") {
  field(DESC, "Chnl 13 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:214:FBCKMODE_S")
}

record(seq, "MCOR:EXT:214:FBCKMODE_S") {
   field(DESC, "Chnl 13 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:214:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:214:CSR_C PP")
   field(LNK2, "MCOR:EXT:214:CSR_S PP")
}

record(mbbo, "MCOR:EXT:214:DACMODE_SET") {
  field(DESC, "Chnl 13 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:214:DACMODE_S")
}

record(seq, "MCOR:EXT:214:DACMODE_S") {
   field(DESC, "Chnl 13 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:214:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:214:CSR_C")
   field(LNK2, "MCOR:EXT:214:CSR_S")
}

record(mbbo, "MCOR:EXT:214:RAMPMODE_SET") {
   field(DESC, "Chnl 13 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:214:RAMPMODE_S")
}

record(seq, "MCOR:EXT:214:RAMPMODE_S") {
   field(DESC,"Chnl 13 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:214:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:214:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:214:CSR_S PP")
   field(LNK3, "MCOR:EXT:214:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:214:STDZMODE_SET") {
  field(DESC, "Chnl 13 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:214:STDZMODE_S")
}

record(seq, "MCOR:EXT:214:STDZMODE_S") {
   field(DESC, "Chnl 13 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:214:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:214:CSR_C PP")
   field(LNK2, "MCOR:EXT:214:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:214:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:214:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:214:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:214:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 13")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.BD")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:214:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 13")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BD")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:214:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 13")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:214:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:214:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 13")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:214:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:214:ADC_OVERSAMP") {
	field(DESC, "Chnl 13 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:214:FBCK_OVERSAMP") {
	field(DESC, "Chnl 13 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:214:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 13 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:214:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:214:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "13")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:214:SLOT")
}
record(calc, "MCOR:EXT:214:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:214:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:214:NAME") {
	field(DESC, "MCOR Chnl 13 MAD Name")
        field(VAL,  "XCL3P")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:214:MAGNET") {
	field(DESC, "MCOR Chnl 13 Magnet Device Name")
        field(VAL,  "XCOR:DOG:338:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:214:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "XCOR:DOG:338:COOLING PP")
}#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:215:ISETPT_S") {
	field(DESC, "Chnl 14 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C14S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:215:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:215:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:215:ISETPT_RBCK") {
	field(DESC, "Chnl 14 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C14S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:215:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:215:IACT") {
#	field(DESC, "Chnl 14 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C14S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:215:IMON") {
	field(DESC, "Chnl 14 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C14S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "YCOR:DOG:357:IMON")
}

record(ai, "MCOR:EXT:215:IRIPL") {
	field(DESC, "Chnl 14 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C14S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:DOG:357:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:215:IFBCK") {
	field(DESC, "Chnl 14 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C14S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:215:IACT") {
	field(DESC, "Chnl 14 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C14S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "YCOR:DOG:357:IACT")
}
record(ai, "MCOR:EXT:215:IFBCK_RIPL") {
	field(DESC, "Chnl 14 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C14S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:215:IRANGE_DAC_SET") {
	field(DESC, "Chnl 14 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C14S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:215:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:215:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 14 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C14S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:215:IRANGE_ADC_SET") {
	field(DESC, "Chnl 14 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C14S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:215:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:215:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 14 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C14S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:215:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 14 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C14S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:215:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:215:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 14 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C14S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:215:IRAMPRATE") {
	field(DESC, "Chnl 14 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C14S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "YCOR:DOG:357:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:215:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 14 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C14S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:215:NSAMP_AVE_S") {
	field(DESC, "Chnl 14 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C14S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:215:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:215:NSAMP_AVE_R") {
	field(DESC, "Chnl 14 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C14S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:215:CSR_R") {
	field(DESC, "Chnl 14 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C14S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:215:CSR")
}

record(longout, "MCOR:EXT:215:CSR_S") {
	field(DESC, "Chnl 14 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C14S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:215:CSR_C") {
	field(DESC, "Chnl 14 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C14S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:215:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:215:CSR_C PP")
   field(LNK2, "MCOR:EXT:215:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:215:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:215:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:215:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:215:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:215:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:215:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:215:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:215:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:215:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:215:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:215:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:215:TYPE") {
  field(DESC, "Chnl 14 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:215:TYPE_SEQ")
  field(VAL,  "1")
}

record(seq, "MCOR:EXT:215:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:215:CONFIG_SET")
 field(LNK2, "MCOR:EXT:215:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:215:CONFIG_SET")
 field(LNK4, "MCOR:EXT:215:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:215:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:215:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:215:TYPE.RVAL")
  field(INPB, "MCOR:EXT:215:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:215:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:215:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:215:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:215:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:215:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:215:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:215:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:215:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:215:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:215:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:215:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:215:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:215:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:215:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:215:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:215:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:215:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:215:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:215:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:215:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:215:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:215:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:215:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:215:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:215:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:215:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:215:IMON.HOPR")
  field(LNK3, "MCOR:EXT:215:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:215:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:215:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:215:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:215:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:215:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:215:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:215:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:215:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:215:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:215:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:215:IACT.HOPR")
  field(LNK5, "MCOR:EXT:215:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:215:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:215:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "YCOR:DOG:357:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:215:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:215:ISETPT")
  field(INPE, "MCOR:EXT:215:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:215:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:215:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:215:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:215:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:215:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:215:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:215:VSETPT") {
  field(DESC, "Chnl 14 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:215:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:215:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:215:VSETPT_RBCK") {
  field(DESC, "Chnl 14 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:215:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:215:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:215:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:215:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:215:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:215:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:215:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:215:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:215:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:215:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:215:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:215:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:215:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:215:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:215:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:215:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:215:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:215:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:215:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:215:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:215:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:215:CSR_R")
        field(FLNK,  "MCOR:EXT:215:CSR_SEQ")
}

record(seq, "MCOR:EXT:215:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:215:CSR.B5")
        field(DOL2, "MCOR:EXT:215:CSR.B1")
        field(DOL3, "MCOR:EXT:215:CSR.B2")
        field(DOL4, "MCOR:EXT:215:CSR.B3")
        field(DOL5, "MCOR:EXT:215:CSR.B4")
        field(DOL6, "MCOR:EXT:215:CSR.B0")
        field(LNK1, "MCOR:EXT:215:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:215:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:215:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:215:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:215:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:215:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:215:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:215:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:215:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:215:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:215:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:215:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:215:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:215:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:215:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:215:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:215:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:215:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "YCOR:DOG:357:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:215:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:215:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:215:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:215:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:215:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:215:STATE PP")
   field(LNK2,  "MCOR:EXT:215:STATE PP")
   field(LNK3,  "MCOR:EXT:215:STATE PP")
}
record(bo, "MCOR:EXT:215:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:DOG:357:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:215:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "YCOR:DOG:357:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:215:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:215:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.BE NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:215:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:215:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BE NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:215:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:215:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:215:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:215:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:215:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:215:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:215:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:215:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:215:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:215:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:215:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:215:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:215:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:215:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:215:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:215:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "YCOR:DOG:357:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:215:CONFIG_SET") {
  field(DESC, "Chnl 14 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:215:CONFIG_S")
}

record(seq, "MCOR:EXT:215:CONFIG_S") {
   field(DESC, "Chnl 14 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:215:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:215:CSR_C PP")
   field(LNK2, "MCOR:EXT:215:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:215:FBCKMODE_SET") {
  field(DESC, "Chnl 14 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:215:FBCKMODE_S")
}

record(seq, "MCOR:EXT:215:FBCKMODE_S") {
   field(DESC, "Chnl 14 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:215:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:215:CSR_C PP")
   field(LNK2, "MCOR:EXT:215:CSR_S PP")
}

record(mbbo, "MCOR:EXT:215:DACMODE_SET") {
  field(DESC, "Chnl 14 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:215:DACMODE_S")
}

record(seq, "MCOR:EXT:215:DACMODE_S") {
   field(DESC, "Chnl 14 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:215:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:215:CSR_C")
   field(LNK2, "MCOR:EXT:215:CSR_S")
}

record(mbbo, "MCOR:EXT:215:RAMPMODE_SET") {
   field(DESC, "Chnl 14 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:215:RAMPMODE_S")
}

record(seq, "MCOR:EXT:215:RAMPMODE_S") {
   field(DESC,"Chnl 14 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:215:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:215:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:215:CSR_S PP")
   field(LNK3, "MCOR:EXT:215:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:215:STDZMODE_SET") {
  field(DESC, "Chnl 14 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:215:STDZMODE_S")
}

record(seq, "MCOR:EXT:215:STDZMODE_S") {
   field(DESC, "Chnl 14 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:215:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:215:CSR_C PP")
   field(LNK2, "MCOR:EXT:215:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:215:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:215:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:215:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:215:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 14")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.BE")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:215:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 14")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BE")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:215:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 14")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:215:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:215:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 14")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:215:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:215:ADC_OVERSAMP") {
	field(DESC, "Chnl 14 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:215:FBCK_OVERSAMP") {
	field(DESC, "Chnl 14 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:215:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 14 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:215:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:215:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "14")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:215:SLOT")
}
record(calc, "MCOR:EXT:215:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:215:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:215:NAME") {
	field(DESC, "MCOR Chnl 14 MAD Name")
        field(VAL,  "YCL4P")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:215:MAGNET") {
	field(DESC, "MCOR Chnl 14 Magnet Device Name")
        field(VAL,  "YCOR:DOG:357:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:215:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "YCOR:DOG:357:COOLING PP")
}#! Generated by VisualDCT v2.6
#! DBSTART
#! DBDEND
# Current Readings
# The drive and operating limits are changed at boot, based on the mcor module.
record(ao, "MCOR:EXT:216:ISETPT_S") {
	field(DESC, "Chnl 15 SETPT")
	field(DTYP, "BusAddress")
	field(OUT,  "#C15S6@mcor0.0+0x00,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(DOL,  "MCOR:EXT:216:ISETPT_OUT")
        field(OMSL, "closed_loop")
# This pv is disabled on boot until the pv <dev.:INIT is procssed
        field(DISV, "0")
        field(FLNK, "MCOR:EXT:216:VSETPT")
        field(ASG,  "Internal")
}

record(ai, "MCOR:EXT:216:ISETPT_RBCK") {
	field(DESC, "Chnl 15 SETPT Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C15S6@mcor0.0+0x04,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
        field(FLNK, "MCOR:EXT:216:VSETPT_RBCK")
}

#record(ai, "MCOR:EXT:216:IACT") {
#	field(DESC, "Chnl 15 Monitor ADC")
#	field(DTYP, "BusAddress")
#	field(INP,  "#C15S6@mcor0.0+0x08,le32")
#	field(SCAN, "1 second")
#        field(LINR, "SLOPE")
#        field(ASLO, "0.000001")
#        field(EGU,  "A")
#        field(PREC, "6")
#}

#6/19/2020: - KL rename from IACT_AVE to IMON
record(ai, "MCOR:EXT:216:IMON") {
	field(DESC, "Chnl 15 Monitor Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C15S6@mcor0.0+0x0c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(FLNK, "XCOR:DOG:408:IMON")
}

record(ai, "MCOR:EXT:216:IRIPL") {
	field(DESC, "Chnl 15 Monitor Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C15S6@mcor0.0+0x10,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:DOG:408:IRIPL")
}

# The fbck is what the internal ramping is checking when ramping to the 
# desired setpt.
record(ai, "MCOR:EXT:216:IFBCK") {
	field(DESC, "Chnl 15 Fbck ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C15S6@mcor0.0+0x14,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

# 6/19/2020: - KL rename from IMON to IACT
record(ai, "MCOR:EXT:216:IACT") {
	field(DESC, "Chnl 15 Fbck Avg ADC")
	field(DTYP, "BusAddress")
	field(INP,  "#C15S6@mcor0.0+0x18,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(FLNK, "XCOR:DOG:408:IACT")
}
record(ai, "MCOR:EXT:216:IFBCK_RIPL") {
	field(DESC, "Chnl 15 Fbck Ripple")
	field(DTYP, "BusAddress")
	field(INP,  "#C15S6@mcor0.0+0x1c,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A")
        field(PREC, "6")
}

record(ao, "MCOR:EXT:216:IRANGE_DAC_SET") {
	field(DESC, "Chnl 15 DAC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C15S6@mcor0.0+0x20,le32")
        field(EGU,  "A")
        field(PREC, "4")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30.7692")
        field(HOPR, "30.7692")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:216:ILIMITS.VALA")
}

record(ai, "MCOR:EXT:216:IRANGE_DAC_RBCK") {
	field(DESC, "Chnl 15 DAC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C15S6@mcor0.0+0x20,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30.7692")
        field(PREC, "4")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:216:IRANGE_ADC_SET") {
	field(DESC, "Chnl 15 ADC FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C15S6@mcor0.0+0x24,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(OMSL, "closed_loop")
        field(DOL,  "MCOR:EXT:216:ILIMITS.VALC")
}

record(ai, "MCOR:EXT:216:IRANGE_ADC_RBCK") {
	field(DESC, "Chnl 15 ADC FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C15S6@mcor0.0+0x24,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(PREC, "2")
        field(EGU,  "A")
        field(HOPR, "30")
}

record(ao, "MCOR:EXT:216:IRANGE_FBCK_SET") {
	field(DESC, "Chnl 15 FBCK FullScale")
	field(DTYP, "BusAddress")
	field(OUT,  "#C15S6@mcor0.0+0x3c,le32")
        field(EGU,  "A")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(HOPR, "30")
        field(DOL,  "MCOR:EXT:216:ILIMITS.VALE")
        field(OMSL, "closed_loop")
}

record(ai, "MCOR:EXT:216:IRANGE_FBCK_RBCK") {
	field(DESC, "Chnl 15 FBCK FullScale Rbck")
	field(DTYP, "BusAddress")
	field(SCAN, "1 second")
	field(INP,  "#C15S6@mcor0.0+0x3c,le32")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(HOPR, "30")
        field(PREC, "2")
        field(EGU,  "A")
}

record(ao, "MCOR:EXT:216:IRAMPRATE") {
	field(DESC, "Chnl 15 Ramp Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C15S6@mcor0.0+0x28,le32")
        field(EGU,  "A/sec")
        field(PREC, "2")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(DRVH, "30")
        field(DRVL, "0.5")
        field(LOPR, "0.1")
        field(HOPR, "30")
        field(VAL,  "1.0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
         field(DOL,  "XCOR:DOG:408:IRAMPRATE")
         field(OMSL, "closed_loop")
        info(autosaveFields,"VAL")
}

record(ai, "MCOR:EXT:216:IRAMPRATE_RBCK") {
	field(DESC, "Chnl 15 Ramp Rate Rbck")
	field(DTYP, "BusAddress")
	field(INP,  "#C15S6@mcor0.0+0x28,le32")
	field(SCAN, "1 second")
        field(LINR, "SLOPE")
        field(ASLO, "0.000001")
        field(EGU,  "A/sec")  
        field(PREC, "2")
        field(HOPR, "30")
}

record(mbbo, "MCOR:EXT:216:NSAMP_AVE_S") {
	field(DESC, "Chnl 15 Sample per Ave")
	field(DTYP, "BusAddress")
	field(OUT,  "#C15S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(FLNK, "MCOR:EXT:216:NSAMP_AVE_R")
        field(ASG,  "Internal")
}

record(mbbi, "MCOR:EXT:216:NSAMP_AVE_R") {
	field(DESC, "Chnl 15 Sample per Ave")
	field(DTYP, "BusAddress")
	field(INP,  "#C15S6@mcor0.0+0x2c,le32")
        field(NOBT, "3")
        field(ZRST, "1")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
}

# Control Status Registers
record(longin, "MCOR:EXT:216:CSR_R") {
	field(DESC, "Chnl 15 CSR ReadBack")
	field(DTYP, "BusAddress")
	field(INP,  "#C15S6@mcor0.0+0x30,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:216:CSR")
}

record(longout, "MCOR:EXT:216:CSR_S") {
	field(DESC, "Chnl 15 CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C15S6@mcor0.0+0x34,le32")
}

record(longout, "MCOR:EXT:216:CSR_C") {
	field(DESC, "Chnl 15 CSR Clr")
	field(DTYP, "BusAddress")
	field(OUT,  "#C15S6@mcor0.0+0x38,le32")
}

####################
#  Soft Channels
#
# INIT is processed at boot to initialize 
# critical pvs in the proper order.
#
record(seq, "MCOR:EXT:216:INIT") {
   field(DESC, "MCOR Init")
   field(PINI, "YES")
#
# The configuration clear register is 16-bits.
# writing a 1 bit clears that bit in the 
# configuration register.
   field(DOL1, "65535")
#
# The configuration set register is 16-bits.
# writing a 1 bit sets that bit in the 
# configuration register. Make sure this register is 
# zeroed. 
   field(DOL2, "0")
   field(LNK1, "MCOR:EXT:216:CSR_C PP")
   field(LNK2, "MCOR:EXT:216:CSR_S PP")
   field(DOL3, "0")  # Set No-feedback mode (default)
   field(DOL4, "0")  # Set Open loop  (default)
   field(DOL5, "0")  # Set Normal ramp mode (default)
   field(DOL6, "0")  # Set Standardize direction to Rising (default) 
   field(DOL7, "1")  # Set dac and adc full scale limits
   field(DOL8, "3")  # Set samples per average (2**3=8)
   field(DOL9, "1")  # Set module configuration complete
   field(LNK3, "MCOR:EXT:216:FBCKMODE_SET PP")
   field(LNK4, "MCOR:EXT:216:DACMODE_SET PP")
   field(LNK5, "MCOR:EXT:216:RAMPMODE_SET PP")
   field(LNK6, "MCOR:EXT:216:STDZMODE_SET PP")
   field(LNK7, "MCOR:EXT:216:TYPE.PROC PP")
   field(LNK8, "MCOR:EXT:216:NSAMP_AVE_S PP")
   field(LNK9, "MCOR:EXT:216:CONFIG_SET PP") 
   field(LNKA, "MCOR:EXT:216:IRAMPRATE.PROC PP")  
   field(FLNK, "MCOR:EXT:216:INIT_2")
   field(ASG,  "Internal")
}
record(seq, "MCOR:EXT:216:INIT_2") {
   field(DESC, "MCOR Init")
   field(DOL1, "1")  # Enable processing of ISETPT
   field(LNK1, "MCOR:EXT:216:ISETPT_S.DISV PP")  
   field(ASG,  "Internal")
}

# MCOR Type Selection
record(mbbo, "MCOR:EXT:216:TYPE") {
  field(DESC, "Chnl 15 Full Scale Output")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "3")
  field(ZRST, "Spare")
  field(ONST, "MCOR1")
  field(TWST, "MCOR2")
  field(THST, "MCOR6")
  field(FRST, "MCOR12")
  field(FVST, "MCOR30")
  field(ZRVL, "12")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "6")
  field(FRVL, "12")
  field(FVVL, "30")
  field(FLNK, "MCOR:EXT:216:TYPE_SEQ")
  field(VAL,  "1")
}

record(seq, "MCOR:EXT:216:TYPE_SEQ") {
 field(DESC, "Set full scale range")
 field(ASG, "Internal")
 field(DOL1, "0")  # configure cleared
 field(DOL2, "1")  # set dac and adc full scale range
 field(DOL3, "1")  # set configure complete
 field(DOL4, "1")  # set ramp rate
 field(DOL5, "1")

# disable the module configuration
# set the ADC full scale ranges
# set the DAC full scale ranges and drive limits
# set the ramp rate
# enable the module configuration
#
 field(LNK1, "MCOR:EXT:216:CONFIG_SET")
 field(LNK2, "MCOR:EXT:216:ILIMITS.PROC")
 field(LNK3, "MCOR:EXT:216:CONFIG_SET")
 field(LNK4, "MCOR:EXT:216:IRAMPRATE.PROC")
 field(LNK5, "MCOR:EXT:216:ISETPT.PROC")
 field(ASG,  "Internal")
}

record(aSub, "MCOR:EXT:216:ILIMITS") {
  field(DESC, "Get Mcor Limits")
  field(INAM, "mgntInit")
  field(SNAM, "mgntMcorLimits")
  field(BRSV, "INVALID")

# Inputs:
#  INPA:  MCOR Raw Type (0=spare,1=mcor1,2=mcor2,6=mcor6,12=mcor12,30=mcor30")
#  INPB:  MCOR Type     (0=spare,1=mcor1,2=mcor2,3=mcor6,4=mcor12,5=mcor30")
  field(INPA, "MCOR:EXT:216:TYPE.RVAL")
  field(INPB, "MCOR:EXT:216:TYPE")
  field(FTA, "ULONG")
  field(FTB, "USHORT")

# Outputs:
#        OUTA: dac imax in amps   <dev>:IRANGE_DAC_SET
#        OUTB: dac imin in amps
#        OUTC: adc imax in amps   <dev>:IRANGE_ADC_SET
#        OUTD: adc imin in amps
#        OUTE: fbck imax in amps  <dev>:IRANGE_FBCK_SET
#        OUTF: fbck imin in amps
#  Note:
#       DAC  Limits are set from <dev>:ILIMITS_DAC
#       ADC  Limits are set from <dev>:ILIMITS_ADC
#       FBCK Limits are set from <dev>:ILIMITS_FBCK
  field(FTVA, "DOUBLE")
  field(FTVB, "DOUBLE")
  field(FTVC, "DOUBLE")
  field(FTVD, "DOUBLE")
  field(FTVE, "DOUBLE")
  field(FTVF, "DOUBLE")
  field(FTVG, "LONG")
  field(FTVH, "LONG")
  field(FTVI, "LONG")
  field(FTVJ, "LONG")
  field(FTVK, "LONG")
  field(FTVL, "LONG")
  field(FLNK, "MCOR:EXT:216:ILIMITS_DAC")
  field(ASG,  "Internal")
}

# Set the DAC full scale range, current drive and operating limits
record(seq, "MCOR:EXT:216:ILIMITS_DAC") {
  field(DESC, "Set DAC Limits")
  field(DOL1, "MCOR:EXT:216:ILIMITS.VALA")
  field(DOL2, "MCOR:EXT:216:ILIMITS.VALA")
  field(DOL3, "MCOR:EXT:216:ILIMITS.VALB")
  field(DOL4, "MCOR:EXT:216:ILIMITS.VALA")
  field(DOL5, "MCOR:EXT:216:ILIMITS.VALB")
  field(DOL6, "MCOR:EXT:216:ILIMITS.VALE")
  field(DOL7, "MCOR:EXT:216:ILIMITS.VALF")
  field(DOL8, "MCOR:EXT:216:ILIMITS.VALE")
  field(DOL9, "MCOR:EXT:216:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:216:IRANGE_DAC_SET PP")
  field(LNK2, "MCOR:EXT:216:ISETPT_S.DRVH")
  field(LNK3, "MCOR:EXT:216:ISETPT_S.DRVL")
  field(LNK4, "MCOR:EXT:216:ISETPT_S.HOPR")
  field(LNK5, "MCOR:EXT:216:ISETPT_S.LOPR")
  field(LNK6, "MCOR:EXT:216:ISETPT.DRVH")
  field(LNK7, "MCOR:EXT:216:ISETPT.DRVL")
  field(LNK8, "MCOR:EXT:216:ISETPT.HOPR")
  field(LNK9, "MCOR:EXT:216:ISETPT.LOPR PP")
  field(FLNK, "MCOR:EXT:216:ILIMITS_ADC")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:216:ILIMITS_ADC") {
  field(DESC, "Set ADC Limits")
  field(DOL1, "MCOR:EXT:216:ILIMITS.VALC")
  field(DOL2, "MCOR:EXT:216:ILIMITS.VALC")
  field(DOL3, "MCOR:EXT:216:ILIMITS.VALD")

  field(LNK1, "MCOR:EXT:216:IRANGE_ADC_SET PP")
  field(LNK2, "MCOR:EXT:216:IMON.HOPR")
  field(LNK3, "MCOR:EXT:216:IMON.LOPR PP")
  field(FLNK, "MCOR:EXT:216:ILIMITS_FBCK")
  field(ASG,  "Internal")
}

# Set the ADC and Fbck full scale range, current drive and operating limits
record(seq, "MCOR:EXT:216:ILIMITS_FBCK") {
  field(DESC, "Set FBCK Limits")
  field(DOL1, "MCOR:EXT:216:ILIMITS.VALE")
  field(DOL2, "MCOR:EXT:216:ILIMITS.VALE")
  field(DOL3, "MCOR:EXT:216:ILIMITS.VALF")
  field(DOL4, "MCOR:EXT:216:ILIMITS.VALE")
  field(DOL5, "MCOR:EXT:216:ILIMITS.VALF")

  field(LNK1, "MCOR:EXT:216:IRANGE_FBCK_SET PP")
  field(LNK2, "MCOR:EXT:216:IFBCK.HOPR")
  field(LNK3, "MCOR:EXT:216:IFBCK.LOPR PP")
  field(LNK4, "MCOR:EXT:216:IACT.HOPR")
  field(LNK5, "MCOR:EXT:216:IACT.LOPR PP")
  field(ASG,  "Internal")
}



# Current setpoint.
# The drive limits are changed upon boot, based on the 
# mcor module type. The default drive limits are set to
# an mcor30
record(ao, "MCOR:EXT:216:ISETPT") {
  field(DESC, "Current Setpoint")
  field(EGU,  "A")
  field(PREC, "6")
  field(DRVH, "30.7692")
  field(DRVL,"-30.7692")
  field(MDEL, "-1")
  field(OUT, "MCOR:EXT:216:ISETPT_OUT PP")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(DOL,  "XCOR:DOG:408:ISETPT")
#
# Make this supervisory so we can have control of the slider
# on the mcor diagnostic panel. At boot up the setpt will be
# restored for this pv.
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

# Converting from Amps to Milliamps.
# We have a temporary fix to apply an extra
# gain and offset. This will later be done 
# in hardware as part of calibration.
record(calc, "MCOR:EXT:216:ISETPT_OUT") {
  field(DESC, "Current Ouput in uA")
  field(ASG,  "Internal")
  field(EGU,  "uA") 
  field(CALC, "(A*E)+F")
  field(INPA, "MCOR:EXT:216:ISETPT")
  field(INPE, "MCOR:EXT:216:ISETPT_SLOPE")
  field(INPF, "MCOR:EXT:216:ISETPT_OFFSET")
  field(INPG, "MCOR:EXT:216:ISETPT.DRVH")
  field(INPH, "MCOR:EXT:216:ISETPT.DRVL")
  field(FLNK, "MCOR:EXT:216:ISETPT_S")
  field(ASG,  "Internal")
}

record(ao, "MCOR:EXT:216:ISETPT_SLOPE") {
  field(DESC, "Current Output Gain")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "1.0")
  field(ASG, "Internal")
  info(autosaveFields,"VAL")

}

record(ao, "MCOR:EXT:216:ISETPT_OFFSET") {
  field(DESC, "Current Output Offset")
  field(DTYP, "Soft Channel")
  field(EGU,  "A")
  field(PREC, "4")
  field(PINI, "YES")
  field(VAL,  "0.0")
  info(autosaveFields,"VAL")
}

# Calculated Voltage Readings 
record(calc, "MCOR:EXT:216:VSETPT") {
  field(DESC, "Chnl 15 Voltage SETPT")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:216:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:216:ISETPT")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:216:VSETPT_RBCK") {
  field(DESC, "Chnl 15 Voltage SETPT Rbck")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:216:I2VSLOPE_DAC")
  field(INPC, "MCOR:EXT:216:ISETPT_RBCK")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc,  "MCOR:EXT:216:VACT") {
  field(DESC, "Monitor Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:216:I2VSLOPE_ADC")
  field(INPC, "MCOR:EXT:216:IACT CPP MS")
  field(EGU,  "V")
  field(PREC, "4")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}


record(calc,  "MCOR:EXT:216:VMON") {
  field(DESC, "Feedback Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:216:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:216:IMON CPP MS")
  field(EGU,  "V")
  field(PREC, "4")  
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# So process this record if ADC_RIPL changes, but only
# if VRIPL.SCAN is set to process passive. Use CP instead
# of CPP if you want to set VRIPL.SCAN to something other
# than process passive
record(calc,  "MCOR:EXT:216:VRIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:216:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:216:IRIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

record(calc,  "MCOR:EXT:216:VFBCK_RIPL") {
  field(DESC, "Ripple Voltage")
  field(CALC, "A=0?C+B:(C/A)+B")
  field(INPA, "MCOR:EXT:216:I2VSLOPE_FBCK")
  field(INPC, "MCOR:EXT:216:IFBCK_RIPL CPP")
  field(EGU,  "V")
  field(PREC, "2")
  field(HOPR, "10.0")
  field(LOPR, "-10.0")
}

# Conversion
# Voltage conversion from Current 
# The adc voltage range is +/-20V 18-bit 
# The adc voltage range with regard to current is +/-10V
# 
# Voltage = (Current/Slope) + Offset
# Slope   =  Max MCOR Current/10
record(calc, "MCOR:EXT:216:I2VSLOPE_DAC") {
  field(DESC, "DAC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:216:IRANGE_DAC_SET CPP MS")
  field(PREC, "5")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:216:I2VSLOPE_FBCK") {
  field(DESC, "Fbck I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:216:IRANGE_FBCK_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

record(calc, "MCOR:EXT:216:I2VSLOPE_ADC") {
  field(DESC, "ADC I-to-V slope")
  field(CALC, "A/10")
  field(INPA, "MCOR:EXT:216:IRANGE_ADC_SET CPP MS")
  field(PREC, "4")
  field(EGU,  "A/V")
  field(ASG,  "Internal")
}

# Status Register
record(mbbiDirect, "MCOR:EXT:216:CSR") {
	field(DESC,  "Status Register")
        field(NOBT,  "7")
	field(INP,   "MCOR:EXT:216:CSR_R")
        field(FLNK,  "MCOR:EXT:216:CSR_SEQ")
}

record(seq, "MCOR:EXT:216:CSR_SEQ") {
        field(DESC, "CSR  Sequence")
        field(DOL1, "MCOR:EXT:216:CSR.B5")
        field(DOL2, "MCOR:EXT:216:CSR.B1")
        field(DOL3, "MCOR:EXT:216:CSR.B2")
        field(DOL4, "MCOR:EXT:216:CSR.B3")
        field(DOL5, "MCOR:EXT:216:CSR.B4")
        field(DOL6, "MCOR:EXT:216:CSR.B0")
        field(LNK1, "MCOR:EXT:216:RAMPSTATE PP")
        field(LNK2, "MCOR:EXT:216:FBCKMODESTATE PP")
        field(LNK3, "MCOR:EXT:216:DACMODESTATE PP")
        field(LNK4, "MCOR:EXT:216:RAMPMODESTATE PP")
        field(LNK5, "MCOR:EXT:216:STDZMODESTATE PP")
        field(LNK6, "MCOR:EXT:216:CONFIGSTATE PP")
}

record(mbbi, "MCOR:EXT:216:CONFIGSTATE") {
  field(DESC,"Chnl Configured Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:216:CSR.B0")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
}

record(mbbi, "MCOR:EXT:216:FBCKMODESTATE") {
  field(DESC, "Feedback Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:216:CSR.B1")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
}

record(mbbi, "MCOR:EXT:216:DACMODESTATE") {
  field(DESC, "DAC Output Mode Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:216:CSR.B2")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
}

record(mbbi, "MCOR:EXT:216:RAMPMODESTATE") {
  field(DESC,"Ramp Mode")
  field(DTYP, "Raw Soft Channel")
  field(INP, "MCOR:EXT:216:CSR.B3")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Normal")
  field(ONST, "Immediate")
}

record(mbbi, "MCOR:EXT:216:STDZMODESTATE") {
  field(DESC, "Stdz Direction Readback")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:216:CSR.B4")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
}

record(mbbi, "MCOR:EXT:216:RAMPSTATE") {
  field(DESC, "Ramp Status")
  field(DTYP, "Raw Soft Channel")
  field(INP,  "MCOR:EXT:216:CSR.B5")
  field(NOBT, "1")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(ZRST, "OFF")
  field(ONST, "BUSY")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(FLNK, "XCOR:DOG:408:RAMPSTATE MSS")
}

# Bulk Power Supply On/Off Status
# The EMCOR Controller firmware does provided on/off bulok ps control
# via backplane, and the EMCOR EPICS driver provides support. However, 
# this bulk on/off capabilty requires a hardware interface chassis between 
# the bulk and the MCOR crate, which has not been designed. Therefore 
# a soft pvs have been provided, which gets its data from another
# pv that reads the bulk on/off status from the power supply (genesys)
# directly or from a plc, which is connected to the power supply 
# on/off signal. The on/off status of each MCOR channel is generated from 
# this MCOR Bulk on/off status in combination with the MCOR Fault status 
# for this channel. The MCOR fault status is included because an MCOR
# channel can be faulted while the bulk supply is on.
#
# SPECIAL CASE:
# There are three (3) special cases of hardware configuration including
# the hard and soft x-ray chicanes in the undulator and the xleap chicane 
# in the ltu. For these three (2) installations circuitry has been added 
# to provide a separate  on/off control of individual mcor channels, which 
# is used by the chicane string main. This hardware includes a contactor 
# to provide the on/off control. The contactor which is controlled and 
# monitored by beckhoff digial i/o modules, to open/close the contactor
# and to read the state of the contactor. For these three chicanes the
# main mcor channel ps has an on/off control and status, separate from 
# the MCOR bulk status. If a contactor exists the PV for the on/off
# is defined in the field INPE. Otherwise, this field is set to the
# default(1), as shown below:
#
#    INPE=1 - The default for all but ltu and und chicanes w/contactor
#    INPE=<mag>CONTACTOR_STATE CP
#
# The STATE_CALC pv is overloaded in mgntApp/Db/und/mgnt_und1_bkhf.substitutions
# for the chicanes, which only instantiates the INPE field.
#
#    VAL:  (output value)
#        0 - do nothing, unknown state
#        1 - ps state off
#        2 - ps state on
#
record(calcout, "MCOR:EXT:216:STATE_CALC") {
   field(DESC, "PS Status")
#
# If the bulk ps state is invalid, do nothing.  If an the fault pv is invalid
# output then set mcor chan state to the bulk state. If the bulk ps is on, the
# mcor chan state is on, and the mcor chan is not faulted, then output set
# mcor chan state to on (1). Otherwise, set the mcor chan state to off (0).
#
   field(CALC, "A=3?0:D=3?3:A&&E&&(B=0)?2:1")
   field(OUT,  "MCOR:EXT:216:STATE_SEQ.SELN PP")
   field(INPA, "MCOR:EXT:200:PS_STATE")
   field(INPB, "MCOR:EXT:216:INTLKSUMY CP")
   field(INPC, "MCOR:EXT:200:PS_STATE.SEVR") 
   field(INPD, "MCOR:EXT:216:INTLKSUMY.SEVR")
   field(INPE, "1")
}
record(seq, "MCOR:EXT:216:STATE_SEQ")
{
   field(DESC, "PS State Sequence")
   field(SELM,  "Specified")
   field(DOL2,  "1")
   field(DOL3,  "MCOR:EXT:200:PS_STATE")
   field(LNK1,  "MCOR:EXT:216:STATE PP")
   field(LNK2,  "MCOR:EXT:216:STATE PP")
   field(LNK3,  "MCOR:EXT:216:STATE PP")
}
record(bo, "MCOR:EXT:216:STATE") {
   field(DESC, "Bulk PS Status")
   field(ZNAM, "OFF")
   field(ONAM, "ON")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:DOG:408:STATE PP MSS")
}

# Bulk Power Supply Turned off by User 
record(bo, "MCOR:EXT:216:TURNEDOFF") {
   field(DESC, "Bulk PS Turned Off by User")
   field(ZNAM, "NO")
   field(ONAM, "YES")
   field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF NPP MSS")
   field(OMSL, "closed_loop")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
    field(OUT, "XCOR:DOG:408:TURNEDOFF PP MSS")
}

# Bulk Power Supply On/Off Control
# The EMCOR Controller firmware does provided on/off ps control
# via backplane connectors and the EMCOR EPICS driver does
# provides support for these signals. However, this has not 
# been implimented as a hardware interface chassis between 
# the bulk and the MCOR crate is required. Since this
# chassis has not been designed yet, soft pvs have been provided.
# So the on/off status of each MCOR channel is generated from the
# MCOR Bulk on/off status and the MCOR Fault status for this channel.
#
# The exception is the hard and soft x-ray chicanes in the undulator 
# and the xleap chicane in the ltu. Circuitry has been added for
# the on/off control of individual mcor channels used by the chicane
# string main. This hardware includes a contactor and beckhoff 
# digial i/o modules, which provide the on/off control and status of
# the inividual mcor channel for the main. Therefore the mcor channel
# ps setpt here will set open/close this contactor
#
# To control the ps On/Off for these chicane magnets set the 
# macros to the following, otherwise leave the default of blank:
#
#  OUT = <dev>:CONTACTOR_SETPT PP
#  DOL = <mag>:STATESETPT.RVAL
#
# This pv is overloaded in mgntApp/Db/common/mgnt_soft_calcout.template
# for the chicanes.
#
record(bo, "MCOR:EXT:216:STATESETPT") {
            field(DESC, "Bulk PS On/Off Ctrl")
            field(DTYP, "Raw Soft Channel")
            field(ZNAM, "OFF")
            field(ONAM, "ON")
            field(DOL,  "")
            field(OUT,  "")
}

# MCOR fault status
record(bi, "MCOR:EXT:216:FAULTSTATE") {
  field(DESC, "Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.BF NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:216:INTLKSUMY_CALC")
}

record(bi, "MCOR:EXT:216:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BF NPP MSS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:216:INTLKSUMY_CALC")
}

record(calcout, "MCOR:EXT:216:FLOW_FAULTSTATE_CALC") {
  field(DESC, "Water Flow Fault State Check")
  field(CALC, "A&&B?1:0")
  field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:216:COOLING NPP NMS")
  field(OUT,  "MCOR:EXT:216:FLOW_FAULTSTATE PP") 
}

record(bi, "MCOR:EXT:216:FLOW_FAULTSTATE") {
  field(DESC, "Water Flow Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:216:FLOW_FAULTSTATE_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:216:INTLKSUMY_CALC")
}

# If severity is invaild then output a zero (0) value
record(calcout, "MCOR:EXT:216:INTLKSUMY_CALC") {
  field(DESC, "Interlock Summary Calculation")
  field(CALC, "A||B||C||D||E?1:0")
  field(INPA, "MCOR:EXT:216:FAULTSTATE NPP MSS")
  field(INPB, "MCOR:EXT:216:LATCHED_FAULTSTATE NPP NMS")
  field(INPC, "MCOR:EXT:216:MAGNET_STATE NPP NMS")
  field(INPD, "MCOR:EXT:216:LATCHED_MAGNET_STATE NPP NMS")
  field(INPE, "MCOR:EXT:216:FLOW_FAULTSTATE NPP NMS")
  field(IVOA, "Set output to IVOV")
  field(IVOV, "0")
  field(OUT,  "MCOR:EXT:216:INTLKSUMY PP MSS")
}

record(bo, "MCOR:EXT:216:INTLKSUMY") {
  field(DESC, "Interlock Summary")
  field(DTYP, "Soft Channel")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(DOL,  "MCOR:EXT:216:INTLKSUMY_CALC NPP MSS")
  field(OMSL, "closed_loop")

# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
   field(OUT, "XCOR:DOG:408:INTLKSUMY PP MSS")
}

# Control Register Ouputs 
record(mbbo, "MCOR:EXT:216:CONFIG_SET") {
  field(DESC, "Chnl 15 Configured")
  field(DTYP, "Raw Soft Channel")
  field(ZRST, "Cleared")
  field(ONST, "Configured")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:216:CONFIG_S")
}

record(seq, "MCOR:EXT:216:CONFIG_S") {
   field(DESC, "Chnl 15 Configured")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:216:CONFIG_SET.RVAL")
   field(DOL1, "1")
   field(DOL2, "1")
   field(LNK1, "MCOR:EXT:216:CSR_C PP")
   field(LNK2, "MCOR:EXT:216:CSR_S PP")
}

# Note that when feedback mode is set the
# ramp rate and closed loop settings are ignored.
record(mbbo, "MCOR:EXT:216:FBCKMODE_SET") {
  field(DESC, "Chnl 15 Configured")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Normal")
  field(ONST, "Feedback")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK, "MCOR:EXT:216:FBCKMODE_S")
}

record(seq, "MCOR:EXT:216:FBCKMODE_S") {
   field(DESC, "Chnl 15 Fbck Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:216:FBCKMODE_SET.RVAL")
   field(DOL1, "2")
   field(DOL2, "2")
   field(LNK1, "MCOR:EXT:216:CSR_C PP")
   field(LNK2, "MCOR:EXT:216:CSR_S PP")
}

record(mbbo, "MCOR:EXT:216:DACMODE_SET") {
  field(DESC, "Chnl 15 DAC Output Mode")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Open Loop")
  field(ONST, "Closed Loop")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:216:DACMODE_S")
}

record(seq, "MCOR:EXT:216:DACMODE_S") {
   field(DESC, "Chnl 15 DAC Ouput Mode")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:216:DACMODE_SET.RVAL")
   field(DOL1, "4")
   field(DOL2, "4")
   field(LNK1, "MCOR:EXT:216:CSR_C")
   field(LNK2, "MCOR:EXT:216:CSR_S")
}

record(mbbo, "MCOR:EXT:216:RAMPMODE_SET") {
   field(DESC, "Chnl 15 Set Ramp Mode")
   field(DTYP, "Raw Soft Channel")
   field(NOBT, "1")
   field(ZRST, "Normal")
   field(ONST, "Immediate")
   field(ZRVL, "1")
   field(ONVL, "6")
   field(FLNK,  "MCOR:EXT:216:RAMPMODE_S")
}

record(seq, "MCOR:EXT:216:RAMPMODE_S") {
   field(DESC,"Chnl 15 Ramp Mode")
   field(SELM, "Mask")
   field(SELL, "MCOR:EXT:216:RAMPMODE_SET.RVAL")

# Set normal ramping (0), clear feedback mode and set open loop (0) 
   field(LNK1, "MCOR:EXT:216:CSR_C PP")
   field(DOL1, "14")

# Set no ramping
# Next clear feedback mode and set open loop (0)
   field(LNK2, "MCOR:EXT:216:CSR_S PP")
   field(LNK3, "MCOR:EXT:216:CSR_C PP")
   field(DOL2,  "8")
   field(DOL3,  "5")
   field(ASG,  "Internal")
}

record(mbbo, "MCOR:EXT:216:STDZMODE_SET") {
  field(DESC, "Chnl 15 Stdz Direction")
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "1")
  field(ZRST, "Rising")
  field(ONST, "Falling")
  field(ZRVL, "1")
  field(ONVL, "2")
  field(FLNK,  "MCOR:EXT:216:STDZMODE_S")
}

record(seq, "MCOR:EXT:216:STDZMODE_S") {
   field(DESC, "Chnl 15 Stdz Direction")
   field(SELM, "Specified")
   field(SELL, "MCOR:EXT:216:STDZMODE_SET.RVAL")
   field(DOL1, "16")
   field(DOL2, "16")
   field(LNK1, "MCOR:EXT:216:CSR_C PP")
   field(LNK2, "MCOR:EXT:216:CSR_S PP")
   field(ASG,  "Internal")
}

# Reset - Reset mcor bus and magnet faults
record(bo, "MCOR:EXT:216:RESET") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(DTYP, "Raw Soft Channel")
   field(ZNAM, "NORESET")
   field(ONAM, "RESET")
   field(OUT,  "MCOR:EXT:216:RESET_ALL PP")
}
record(dfanout,"MCOR:EXT:216:RESET_ALL") {
   field(DESC, "Reset MCOR fault Crate 2")
   field(OUTA,  "MCOR:EXT:200:RESET PP")
   field(OUTB,  "MCOR:EXT:200:MAGNET8_RESET PP")
}

# Fault Channels
record(bi, "MCOR:EXT:216:FAULTSTATE") {
  field(DESC, "Fault Status Chnl 15")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:FAULTSTATE.BF")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# Latched fault channels
record(bi, "MCOR:EXT:216:LATCHED_FAULTSTATE") {
  field(DESC, "Latched Fault Status Chnl 15")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BF")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
}

# LCW fault 
record(bi, "MCOR:EXT:216:MAGNET_STATE") {
  field(DESC, "Fault Status Chnl 15")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:216:INTLKSUMY_CALC")
}

# LCW Latched fault
record(bi, "MCOR:EXT:216:LATCHED_MAGNET_STATE") {
  field(DESC, "Latched Fault Status Chnl 15")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(FLNK, "MCOR:EXT:216:INTLKSUMY_CALC")
}

# ADC Oversampling Rate
record(mbbi, "MCOR:EXT:216:ADC_OVERSAMP") {
	field(DESC, "Chnl 15 ADC Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(mbbi, "MCOR:EXT:216:FBCK_OVERSAMP") {
	field(DESC, "Chnl 15 Fbck Oversampling Rate Rbck")
        field(DTYP, "Raw Soft Channel")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
}

record(bi, "MCOR:EXT:216:ADC_EXT_REF_RBCK") {
	field(DESC, "Chnl 15 ADC External Ref Rbck")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Internal Ref")
        field(ONAM, "External Ref")
}

# MCOR Module Information
record(longout, "MCOR:EXT:216:CRATE") {
	field(DESC, "MCOR Crate")
        field(DRVH, "6")
        field(HOPR, "6")
        field(VAL,  "2")
        field(PINI, "YES")
}
record(longout, "MCOR:EXT:216:CHAN") {
	field(DESC, "MCOR Pci Chnl")
        field(DRVH, "15")
        field(HOPR, "15")
        field(LOPR, "0")
        field(DRVL, "0")
        field(VAL,  "15")
        field(PINI, "YES")
        field(FLNK, "MCOR:EXT:216:SLOT")
}
record(calc, "MCOR:EXT:216:SLOT") {
      field(DESC, "MCOR Slot")
      field(CALC, "A+1")
      field(INPA, "MCOR:EXT:216:CHAN")
      field(HOPR, "16")
      field(LOPR, "1")
}
record(stringout, "MCOR:EXT:216:NAME") {
	field(DESC, "MCOR Chnl 15 MAD Name")
        field(VAL,  "XCL5P")
        field(PINI, "YES")
}
record(stringout, "MCOR:EXT:216:MAGNET") {
	field(DESC, "MCOR Chnl 15 Magnet Device Name")
        field(VAL,  "XCOR:DOG:408:")
        field(PINI, "YES")
}
record(mbbo, "MCOR:EXT:216:COOLING") {

  field(DESC, "Type of cooling")
  field(NOBT, "2")
  field(ZRST, "AIR")
  field(ONST, "WATER")
  field(TWST, "HELIUM")
  field(THST, "NONE")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(PINI, "YES")
  field(VAL,  "0")
#
# If this is a spare mcor channel, instanciate the LNK macro with a "#" 
        field(OUT, "XCOR:DOG:408:COOLING PP")
}
############## System Information ##############
record(stringin,"MCOR:EXT:200:FW_VERS") {
	field(DESC, "Crate 2 Firmware Ver")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S0@mcor0.0+0x5c0,be8(8)")
	field(PINI, "YES")
}

record(stringin,"MCOR:EXT:200:SYSID") {
	field(DESC, "Crate 2 System Info")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S0@mcor0.0+0x5c8,be8(4)")
	field(PINI, "YES")
}


record(stringin,"MCOR:EXT:200:FW_DATE") {
	field(DESC, "Crate 2 Firware Date")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S0@mcor0.0+0x5d6,be8(8)")
	field(PINI, "YES")
}

############## MCOR Fault Registers ##############

# Each bit (0-15) represents the respective channel fault status
record(longin, "MCOR:EXT:200:FAULT_R") {
	field(DESC, "MCOR Pwr Module Fault Status")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x480,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:200:FAULTSTATE")
        field(ASG,  "Internal")
}

# Each bit (0-15) represents the respective channel latched fault status
record(longin, "MCOR:EXT:200:LATCHED_FAULT_R") {
	field(DESC, "MCOR Pwr Module Latched Fault Status")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x484,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:200:LATCHED_FAULTSTATE")
        field(ASG,  "Internal")
}

# Writing to the Latche Fault Reset register will clear the latched faults.
record(longout, "MCOR:EXT:200:FAULT_RESET_S") {
	field(DESC, "Reset Latched Fault")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x488,le32")
}

record(longin, "MCOR:EXT:200:FAULT_CSR_R") {
	field(DESC, "Fault CSR Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x48C,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:200:RESETSTATE")
        field(ASG,  "Internal")
}

# Pulse the FAULT_CSR_S and FULT_CSR_C to send a reset
# signal on the back plane, which will clear the faults for
# all modules. However, it will not clear the latched faults
# To do this you need to write to the FAULT_RESET_S
# after you send out the pulse.

record(longout, "MCOR:EXT:200:FAULT_CSR_S") {
	field(DESC, "Fault CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x490,le32")
}

record(longout, "MCOR:EXT:200:FAULT_CSR_C") {
	field(DESC, "Fault CSR Clear")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x494,le32")
}

record(longin, "MCOR:EXT:200:FAULT_BYPASS_R") {
	field(DESC, "Fault Bybass Status")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x498,le32")
	field(SCAN, "1 second")
}

record(longout, "MCOR:EXT:200:FAULT_BYPASS_S") {
	field(DESC, "Set Fault Bypass")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x49c,le32")
}

record(longout, "MCOR:EXT:200:FAULT_BYPASS_C") {
	field(DESC, "Clear Fault Bypass")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x4a0,le32")
}


############### Interlock and Magnet Fault Registers #############


record(longin, "MCOR:EXT:200:EXT_INTLK_R") {
	field(DESC, "External Interlock Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x50c,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:200:EXT_INTLK_STATE")
}

record(longout, "MCOR:EXT:200:EXT_INTLK_S") {
	field(DESC, "External Interlock Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x504,le32")
}

record(longout, "MCOR:EXT:200:EXT_INTLK_C") {
	field(DESC, "External Interlock Clear")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x508,le32")
}

record(longin, "MCOR:EXT:200:MAGNET_FAULT_R") {
	field(DESC, "Magnet Fault Status")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x50c,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:200:MAGNET_STATE")
}

record(longin, "MCOR:EXT:200:LATCHED_MAGNET_FAULT_R") {
	field(DESC, "Magnet Latched Fault Status")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x510,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:200:LATCHED_MAGNET_STATE")
}

record(longout, "MCOR:EXT:200:MAGNET_FAULT_C") {
	field(DESC, "Magnet Latched Fault Clear")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x514,le32")
}


############# ADC Control Registers ##############

record(longin, "MCOR:EXT:200:ADC_CSR_R") {
	field(DESC, "ADC CSR Readback")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x440,le32")
	field(SCAN, "1 second")
        field(FLNK, "MCOR:EXT:200:ADC_CSR")
}

record(longout, "MCOR:EXT:200:ADC_CSR_S") {
	field(DESC, "ADC CSR Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x444,le32")
}

record(longout, "MCOR:EXT:200:ADC_CSR_C") {
	field(DESC, "ADC CSR Clear")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x448,le32")
}

# A default oversamping rage of 64 is set in the FPGA.
# Increasing the ovesampling rate will decrease the conversion of the ADC,
# this will affect the 100Khz normal operations of the ADC.
# Note:set the default oversamping rate
record(seq,"MCOR:EXT:200:INIT") {
      field(DESC, "Crate 2 Init seq")
      field(PINI, "YES")
      field(DLY1, "2")
      field(DLY2, "2")
      field(DLY3, "2")
      field(DLY4, "2")
      field(DLY5, "5")
      field(DOL1, "1")
      field(DOL2, "1")
      field(DOL3, "1")
      field(DOL4, "1")
      field(LNK1, "MCOR:EXT:200:ADC_OVERSAMP_SET.PROC PP")
      field(LNK2, "MCOR:EXT:200:ADC2_OVERSAMP_SET.PROC PP")
      field(LNK3, "MCOR:EXT:200:FBCK_OVERSAMP_SET.PROC PP")
      field(LNK4, "MCOR:EXT:200:FBCK2_OVERSAMP_SET.PROC PP")
}

record(longout, "MCOR:EXT:200:OVERSAMP_S") {
	field(DESC, "ADC Oversampling Rate Set")
	field(DTYP, "BusAddress")
	field(OUT,  "#C0S6@mcor0.0+0x44c,le32")
}

record(longin, "MCOR:EXT:200:OVERSAMP_R") {
	field(DESC, "ADC Oversampling Rate Rbk")
	field(DTYP, "BusAddress")
        field(SCAN, "1 second")
	field(INP,  "#C0S6@mcor0.0+0x44c,le32")
        field(FLNK, "MCOR:EXT:200:OVERSAMP_SEQ")
}

record(longin, "MCOR:EXT:200:ADC_EXT_REF_R") {
	field(DESC, "MCOR ADC External Ref")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x450,le32")
}

############## Soft PVs ####################

# ADC Control Registers Soft PVs

record(bo, "MCOR:EXT:200:ADC_RESET") {
        field(DESC, "MCOR ADC Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:ADC_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:ADC_RESET_SEQ") {
        field(DESC,"MCOR ADC Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "1")
        field(DOL2,  "1")
# Delay the processing of LNK2 for DLY seconds
        field(DLY2,  "0.4")

        field(LNK1, "MCOR:EXT:200:ADC_CSR_S PP")
        field(LNK2, "MCOR:EXT:200:ADC_CSR_C PP")
}

record(bo, "MCOR:EXT:200:PS_RESET") {
        field(DESC, "Bulk ADC Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:PS_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:PS_RESET_SEQ") {
        field(DESC,"Bulk ADC Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "2")
        field(DOL2,  "2")
# Delay the processing of LNK2 for DLY seconds
        field(DLY2,  "0.4")
        field(LNK1, "MCOR:EXT:200:ADC_CSR_S PP")
        field(LNK2, "MCOR:EXT:200:ADC_CSR_C PP")
}

record(bo, "MCOR:EXT:200:ADC_TO_RESET") {
        field(DESC, "ADC Timout Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:ADC_TO_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:ADC_TO_RESET_SEQ") {
        field(DESC,"ADC Timout Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "4")
        field(DOL2,  "4")
# Delay the processing of LNK2 for DLY seconds
        field(DLY2,  "0.4")
        field(LNK1, "MCOR:EXT:200:ADC_CSR_S PP")
        field(LNK2, "MCOR:EXT:200:ADC_CSR_C PP")
}

record(bo, "MCOR:EXT:200:PS_TO_RESET") {
        field(DESC, "Bulk ADC Timout Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:PS_TO_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:PS_TO_RESET_SEQ") {
        field(DESC,"Bulk ADC Timout Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "8")
        field(DOL2,  "8")
# Delay the processing of LNK2 for DLY seconds
        field(DLY2,  "0.4")
        field(LNK1, "MCOR:EXT:200:ADC_CSR_S PP")
        field(LNK2, "MCOR:EXT:200:ADC_CSR_C PP")
}

record(mbbiDirect, "MCOR:EXT:200:ADC_CSR"){
        field(DESC, "MCOR ADC Control Status Rbck")
        field(NOBT, "5")
        field(INP,  "MCOR:EXT:200:ADC_CSR_R NPP")
        field(FLNK, "MCOR:EXT:200:ADC_RESET_STATE")
}

record(bi, "MCOR:EXT:200:ADC_RESET_STATE") {
        field(DESC, "MCOR ADC Reset Status")
        field(DTYP, "Raw Soft Channel")
	field(INP,  "MCOR:EXT:200:ADC_CSR.B0 NPP MS")
        field(ZNAM, "Not Asserted")
        field(ONAM, "Asserted")
        field(OSV, "MAJOR")
        field(FLNK, "MCOR:EXT:200:PS_RESET_STATE")
}
record(bi, "MCOR:EXT:200:PS_RESET_STATE") {
        field(DESC, "Bulk ADC Reset Status")
        field(DTYP, "Raw Soft Channel")
	field(INP,  "MCOR:EXT:200:ADC_CSR.B1 NPP MS")
        field(ZNAM, "Not Asserted")
        field(ONAM, "Asserted")
        field(OSV, "MAJOR")
        field(FLNK, "MCOR:EXT:200:ADC_TO_STATE")
}
record(bi, "MCOR:EXT:200:ADC_TO_STATE") {
        field(DESC, "ADC Timout Status")
        field(DTYP, "Raw Soft Channel")
	field(INP,  "MCOR:EXT:200:ADC_CSR.B2 NPP MS")
        field(ZNAM, "Not Asserted")
        field(ONAM, "Asserted")
        field(OSV, "MAJOR")
        field(FLNK, "MCOR:EXT:200:PS_TO_STATE")
}

record(bi, "MCOR:EXT:200:PS_TO_STATE") {
        field(DESC, "Bulk Timout Status")
        field(DTYP, "Raw Soft Channel")
	field(INP,  "MCOR:EXT:200:ADC_CSR.B3 NPP MS")
        field(ZNAM, "Not Asserted")
        field(ONAM, "Asserted")
        field(OSV, "MAJOR")
}

# Oversampling Soft Channels
record(mbbo, "MCOR:EXT:200:ADC_OVERSAMP_SET") {
	field(DESC, "ADC Ch0-7 Oversampling Rate Set")
	field(DTYP, "Raw Soft Channel")
	field(OUT,  "MCOR:EXT:200:ADC_OVERSAMP_OUT PP")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(VAL, "6")
}
record(mbbo, "MCOR:EXT:200:ADC2_OVERSAMP_SET") {
	field(DESC, "ADC Ch8-15 Oversampling Rate Set")
	field(DTYP, "Raw Soft Channel")
	field(OUT,  "MCOR:EXT:200:ADC2_OVERSAMP_OUT PP")
        field(NOBT, "3")
        field(SHFT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(VAL, "6")
}
record(mbbo, "MCOR:EXT:200:FBCK_OVERSAMP_SET") {
	field(DESC, "Fbck Ch0-7 Oversampling Rate Set")
	field(DTYP, "Raw Soft Channel")
	field(OUT,  "MCOR:EXT:200:FBCK_OVERSAMP_OUT PP")
        field(NOBT, "3")
        field(SHFT, "6")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(VAL, "6")
}
record(mbbo, "MCOR:EXT:200:FBCK2_OVERSAMP_SET") {
	field(DESC, "Fbck Ch7-15 Oversampling Rate Set")
	field(DTYP, "Raw Soft Channel")
	field(OUT,  "MCOR:EXT:200:FBCK2_OVERSAMP_OUT PP")
        field(NOBT, "3")
        field(SHFT, "9")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(SHFT, "9")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(VAL, "6")
}

# Before changing the over sampling rate first readback the
# current sampling rates for adc,fbck and bulk ps and then mask
# in the 3-bit value.
# Note: INPC= 3-bits left shift

record(calcout, "MCOR:EXT:200:FBCK2_OVERSAMP_OUT") {
	field(DESC, "Calc Oversampling Rate Set")
        field(ASG,  "Internal")
        field(CALC, "(B&~C)|A")
        field(INPA, "MCOR:EXT:200:FBCK2_OVERSAMP_SET.RVAL")
        field(INPB, "MCOR:EXT:200:OVERSAMP_R")
        field(INPC, "MCOR:EXT:200:FBCK2_OVERSAMP_SET.MASK")
        field(OUT,  "MCOR:EXT:200:OVERSAMP_S PP")
}
record(calcout, "MCOR:EXT:200:FBCK_OVERSAMP_OUT") {
	field(DESC, "Calc Oversampling Rate Set")
        field(ASG,  "Internal")
        field(CALC, "(B&~C)|A")
        field(INPA, "MCOR:EXT:200:FBCK_OVERSAMP_SET.RVAL")
        field(INPB, "MCOR:EXT:200:OVERSAMP_R")
        field(INPC, "MCOR:EXT:200:FBCK_OVERSAMP_SET.MASK")
        field(OUT,  "MCOR:EXT:200:OVERSAMP_S PP")
}
record(calcout, "MCOR:EXT:200:ADC2_OVERSAMP_OUT") {
	field(DESC, "Calc Oversampling Rate Set")
        field(ASG,  "Internal")
        field(CALC, "(B&~C)|A")
        field(INPA, "MCOR:EXT:200:ADC2_OVERSAMP_SET.RVAL")
        field(INPB, "MCOR:EXT:200:OVERSAMP_R")
        field(INPC, "MCOR:EXT:200:ADC2_OVERSAMP_SET.MASK")
        field(OUT,  "MCOR:EXT:200:OVERSAMP_S PP")
}
record(calcout, "MCOR:EXT:200:ADC_OVERSAMP_OUT") {
	field(DESC, "Calc Oversampling Rate Set")
        field(ASG,  "Internal")
        field(CALC, "(B&~C)|A")
        field(INPA, "MCOR:EXT:200:ADC_OVERSAMP_SET.RVAL")
        field(INPB, "MCOR:EXT:200:OVERSAMP_R")
        field(INPC, "MCOR:EXT:200:ADC_OVERSAMP_SET.MASK")
        field(OUT,  "MCOR:EXT:200:OVERSAMP_S PP")
}

# Readback the over sampling rate (ratio)
record(fanout, "MCOR:EXT:200:OVERSAMP_SEQ") {
        field(DESC, "Oversample Sequence")
        field(ASG,  "Internal")
        field(LNK1, "MCOR:EXT:200:ADC_OVERSAMP")
        field(LNK2, "MCOR:EXT:200:ADC2_OVERSAMP")
        field(LNK3, "MCOR:EXT:200:FBCK_OVERSAMP")
        field(LNK4, "MCOR:EXT:200:FBCK2_OVERSAMP")
}

record(mbbi, "MCOR:EXT:200:ADC_OVERSAMP") {
	field(DESC, "ADC Ch 0-7 Oversamping Rate Rbck")
	field(DTYP, "Raw Soft Channel")
        field(INP,  "MCOR:EXT:200:OVERSAMP_R")
        field(NOBT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
        field(FLNK, "MCOR:EXT:200:ADC_OVERSAMP_SEQ")
}
record(mbbi, "MCOR:EXT:200:ADC2_OVERSAMP") {
	field(DESC, "ADC Ch 7-15 Oversamping Rate Rbck")
	field(DTYP, "Raw Soft Channel")
        field(INP,  "MCOR:EXT:200:OVERSAMP_R")
        field(NOBT, "3")
        field(SHFT, "3")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
        field(FLNK, "MCOR:EXT:200:ADC2_OVERSAMP_SEQ")
}
record(mbbi, "MCOR:EXT:200:FBCK_OVERSAMP") {
	field(DESC, "Fbck Ch 0-7 Oversamping Rate Rbck")
	field(DTYP, "Raw Soft Channel")
        field(INP,  "MCOR:EXT:200:OVERSAMP_R")
        field(NOBT, "3")
        field(SHFT, "6")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
        field(FLNK, "MCOR:EXT:200:FBCK_OVERSAMP_SEQ")
}
record(mbbi, "MCOR:EXT:200:FBCK2_OVERSAMP") {
	field(DESC, "Fbck Ch 7-15 Oversamping Rate Rbck")
	field(DTYP, "Raw Soft Channel")
        field(INP,  "MCOR:EXT:200:OVERSAMP_R")
        field(NOBT, "3")
        field(SHFT, "9")
        field(ZRST, "No OS")
        field(ONST, "2")
        field(TWST, "4")
        field(THST, "8")
        field(FRST, "16")
        field(FVST, "32")
        field(SXST, "64")
        field(SVST, "Invalid")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(TWVL, "2")
        field(THVL, "3")
        field(FRVL, "4")
        field(FVVL, "5")
        field(SXVL, "6")
        field(SVVL, "7")
        field(SVSV, "INVALID")
        field(FLNK, "MCOR:EXT:200:FBCK2_OVERSAMP_SEQ")
        field(ASG, "Internal")
}


record(dfanout, "MCOR:EXT:200:ADC_OVERSAMP_SEQ") {
        field(DESC, "ADC Oversample Sequence")
        field(ASG,  "Internal")
        field(DOL,  "MCOR:EXT:200:ADC_OVERSAMP")
        field(OUTA, "MCOR:EXT:201:ADC_OVERSAMP PP")
        field(OUTB, "MCOR:EXT:202:ADC_OVERSAMP PP")
        field(OUTC, "MCOR:EXT:203:ADC_OVERSAMP PP")
        field(OUTD, "MCOR:EXT:204:ADC_OVERSAMP PP")
        field(OUTE, "MCOR:EXT:205:ADC_OVERSAMP PP")
        field(OUTF, "MCOR:EXT:206:ADC_OVERSAMP PP")
        field(OUTG, "MCOR:EXT:207:ADC_OVERSAMP PP")
        field(OUTH, "MCOR:EXT:208:ADC_OVERSAMP PP")
        field(ASG, "Internal")
}
record(dfanout, "MCOR:EXT:200:ADC2_OVERSAMP_SEQ") {
        field(DESC, "ADC2 Oversample Sequence")
        field(ASG,  "Internal")
        field(DOL,  "MCOR:EXT:200:ADC2_OVERSAMP")
        field(OUTA, "MCOR:EXT:209:ADC_OVERSAMP PP")
        field(OUTB, "MCOR:EXT:210:ADC_OVERSAMP PP")
        field(OUTC, "MCOR:EXT:211:ADC_OVERSAMP PP")
        field(OUTD, "MCOR:EXT:212:ADC_OVERSAMP PP")
        field(OUTE, "MCOR:EXT:213:ADC_OVERSAMP PP")
        field(OUTF, "MCOR:EXT:214:ADC_OVERSAMP PP")
        field(OUTG, "MCOR:EXT:215:ADC_OVERSAMP PP")
        field(OUTH, "MCOR:EXT:216:ADC_OVERSAMP PP")
        field(ASG, "Internal")
}
record(dfanout, "MCOR:EXT:200:FBCK_OVERSAMP_SEQ") {
        field(DESC, "Fbck Oversample Sequence")
        field(ASG,  "Internal")
        field(DOL,  "MCOR:EXT:200:FBCK_OVERSAMP")
        field(OUTA, "MCOR:EXT:201:FBCK_OVERSAMP PP")
        field(OUTB, "MCOR:EXT:202:FBCK_OVERSAMP PP")
        field(OUTC, "MCOR:EXT:203:FBCK_OVERSAMP PP")
        field(OUTD, "MCOR:EXT:204:FBCK_OVERSAMP PP")
        field(OUTE, "MCOR:EXT:205:FBCK_OVERSAMP PP")
        field(OUTF, "MCOR:EXT:206:FBCK_OVERSAMP PP")
        field(OUTG, "MCOR:EXT:207:FBCK_OVERSAMP PP")
        field(OUTH, "MCOR:EXT:208:FBCK_OVERSAMP PP")
        field(ASG, "Internal")
}
record(dfanout, "MCOR:EXT:200:FBCK2_OVERSAMP_SEQ") {
        field(DESC, "Fbck Oversample Sequence")
        field(ASG,  "Internal")
        field(DOL,  "MCOR:EXT:200:FBCK2_OVERSAMP")
        field(OUTA, "MCOR:EXT:209:FBCK_OVERSAMP PP")
        field(OUTB, "MCOR:EXT:210:FBCK_OVERSAMP PP")
        field(OUTC, "MCOR:EXT:211:FBCK_OVERSAMP PP")
        field(OUTD, "MCOR:EXT:212:FBCK_OVERSAMP PP")
        field(OUTE, "MCOR:EXT:213:FBCK_OVERSAMP PP")
        field(OUTF, "MCOR:EXT:214:FBCK_OVERSAMP PP")
        field(OUTG, "MCOR:EXT:215:FBCK_OVERSAMP PP")
        field(OUTH, "MCOR:EXT:216:FBCK_OVERSAMP PP")
        field(ASG, "Internal")
}


# Fault Register Soft Channels
record(bo, "MCOR:EXT:200:RESET") {
        field(DESC, "Clear all MCOR faults")
        field(DTYP, "Soft Channel")
        field(ZNAM, "OFF")
        field(ONAM, "ON")
        field(FLNK, "MCOR:EXT:200:RESETCALC")
}

record(calcout, "MCOR:EXT:200:RESETCALC") {
       field(ASG,  "Internal")
       field(OOPT, "Transition To Non-zero")
       field(CALC, "A")
       field(INPA, "MCOR:EXT:200:RESET")
       field(FLNK, "MCOR:EXT:200:RESET_SEQ")
}

record(seq, "MCOR:EXT:200:RESET_SEQ") {
        field(DESC,"Clear all MCOR faults seq")
        field(ASG, "Internal")
        field(DOL1,  "65535")
        field(DOL2,  "1")
        field(DOL3,  "1")

# Delay the processing of LNK3 for DLY seconds
        field(DLY3,  "0.4")
        field(SELM, "All")
        field(LNK1, "MCOR:EXT:200:FAULT_RESET_S PP")
        field(LNK2, "MCOR:EXT:200:FAULT_CSR_S PP")
        field(LNK3, "MCOR:EXT:200:FAULT_CSR_C PP")
        field(ASG, "Internal")
}

record(mbbi, "MCOR:EXT:200:RESETSTATE") {
        field(DESC, "MCOR Reset Status")
        field(DTYP, "Raw Soft Channel")
	field(INP,  "MCOR:EXT:200:FAULT_CSR_R")
	field(NOBT, "1")
        field(ZRST, "Not Asserted")
        field(ONST, "Asserted")
        field(ZRVL, "0")
        field(ONVL, "1")
        field(FLNK, "MCOR:EXT:200:INHIBITSTATE")
}

#######################
# MCOR Module Fault
#######################
record(mbbi, "MCOR:EXT:200:INHIBITSTATE") {
        field(DESC, "MCOR Inhibit Status")
        field(DTYP, "Raw Soft Channel")
	field(INP,  "MCOR:EXT:200:FAULT_CSR_R")
	field(NOBT, "2")
        field(SHFT, "1")
        field(ZRST, "Not Asserted")
        field(ONST, "Asserted")
        field(ZRVL, "0")
        field(ONVL, "1")
}

record(mbbiDirect,   "MCOR:EXT:200:FAULTSTATE") {
	field(DESC,  "MCOR Pwr Module Fault State")
        field(NOBT,  "16")
	field(INP,   "MCOR:EXT:200:FAULT_R")
        field(FLNK,  "MCOR:EXT:200:FAULTSTATE_SEQ")
}

record(seq, "MCOR:EXT:200:FAULTSTATE_SEQ") {
        field(DESC,  "Fault Status Sequence")
        field(ASG, "Internal")
        field(DOL1,  "MCOR:EXT:200:FAULTSTATE.B0")
        field(DOL2,  "MCOR:EXT:200:FAULTSTATE.B1")
        field(DOL3,  "MCOR:EXT:200:FAULTSTATE.B2")
        field(DOL4,  "MCOR:EXT:200:FAULTSTATE.B3")
        field(DOL5,  "MCOR:EXT:200:FAULTSTATE.B4")
        field(DOL6,  "MCOR:EXT:200:FAULTSTATE.B5")
        field(DOL7,  "MCOR:EXT:200:FAULTSTATE.B6")
        field(DOL8,  "MCOR:EXT:200:FAULTSTATE.B7")
        field(LNK1, "MCOR:EXT:201:FAULTSTATE PP")
        field(LNK2, "MCOR:EXT:202:FAULTSTATE PP")
        field(LNK3, "MCOR:EXT:203:FAULTSTATE PP")
        field(LNK4, "MCOR:EXT:204:FAULTSTATE PP")
        field(LNK5, "MCOR:EXT:205:FAULTSTATE PP")
        field(LNK6, "MCOR:EXT:206:FAULTSTATE PP")
        field(LNK7, "MCOR:EXT:207:FAULTSTATE PP")
        field(LNK8, "MCOR:EXT:208:FAULTSTATE PP")
        field(FLNK, "MCOR:EXT:200:FAULTSTATE_SEQ_2")
        field(ASG, "Internal")
}

record(seq, "MCOR:EXT:200:FAULTSTATE_SEQ_2") {
        field(DESC, "Fault Status fanout")
        field(ASG, "Internal")
        field(DOL1,  "MCOR:EXT:200:FAULTSTATE.B8")
        field(DOL2,  "MCOR:EXT:200:FAULTSTATE.B9")
        field(DOL3,  "MCOR:EXT:200:FAULTSTATE.BA")
        field(DOL4,  "MCOR:EXT:200:FAULTSTATE.BB")
        field(DOL5,  "MCOR:EXT:200:FAULTSTATE.BC")
        field(DOL6,  "MCOR:EXT:200:FAULTSTATE.BD")
        field(DOL7,  "MCOR:EXT:200:FAULTSTATE.BE")
        field(DOL8,  "MCOR:EXT:200:FAULTSTATE.BF")
        field(LNK1, "MCOR:EXT:209:FAULTSTATE PP")
        field(LNK2, "MCOR:EXT:210:FAULTSTATE PP")
        field(LNK3, "MCOR:EXT:211:FAULTSTATE PP")
        field(LNK4, "MCOR:EXT:212:FAULTSTATE PP")
        field(LNK5, "MCOR:EXT:213:FAULTSTATE PP")
        field(LNK6, "MCOR:EXT:214:FAULTSTATE PP")
        field(LNK7, "MCOR:EXT:215:FAULTSTATE PP")
        field(LNK8, "MCOR:EXT:216:FAULTSTATE PP")
        field(ASG, "Internal")
}

#####################################
# Latched Fault Status Soft Channels
#####################################
record(mbbiDirect,   "MCOR:EXT:200:LATCHED_FAULTSTATE") {
	field(DESC,  "MCOR Pwr Module Latched Fault State")
        field(NOBT,  "16")
	field(INP,   "MCOR:EXT:200:LATCHED_FAULT_R MS")
        field(FLNK,  "MCOR:EXT:200:LATCHED_FAULTSTATE_SEQ")
}

record(seq, "MCOR:EXT:200:LATCHED_FAULTSTATE_SEQ") {
        field(DESC,  "Latched Fault Status fanout")
        field(ASG, "Internal")
        field(DOL1,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B0")
        field(DOL2,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B1")
        field(DOL3,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B2")
        field(DOL4,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B3")
        field(DOL5,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B4")
        field(DOL6,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B5")
        field(DOL7,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B6")
        field(DOL8,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B7")
        field(LNK1, "MCOR:EXT:201:LATCHED_FAULTSTATE PP MS")
        field(LNK2, "MCOR:EXT:202:LATCHED_FAULTSTATE PP MS")
        field(LNK3, "MCOR:EXT:203:LATCHED_FAULTSTATE PP MS")
        field(LNK4, "MCOR:EXT:204:LATCHED_FAULTSTATE PP MS")
        field(LNK5, "MCOR:EXT:205:LATCHED_FAULTSTATE PP MS")
        field(LNK6, "MCOR:EXT:206:LATCHED_FAULTSTATE PP MS")
        field(LNK7, "MCOR:EXT:207:LATCHED_FAULTSTATE PP MS")
        field(LNK8, "MCOR:EXT:208:LATCHED_FAULTSTATE PP MS")
        field(FLNK, "MCOR:EXT:200:LATCHED_FAULTSTATE_SEQ_2")
        field(ASG, "Internal")
}

record(seq, "MCOR:EXT:200:LATCHED_FAULTSTATE_SEQ_2") {
        field(DESC, "Latched Fault Status fanout")
        field(ASG, "Internal")
        field(DOL1,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B8")
        field(DOL2,  "MCOR:EXT:200:LATCHED_FAULTSTATE.B9")
        field(DOL3,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BA")
        field(DOL4,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BB")
        field(DOL5,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BC")
        field(DOL6,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BD")
        field(DOL7,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BE")
        field(DOL8,  "MCOR:EXT:200:LATCHED_FAULTSTATE.BF")
        field(LNK1, "MCOR:EXT:209:LATCHED_FAULTSTATE PP MS ")
        field(LNK2, "MCOR:EXT:210:LATCHED_FAULTSTATE PP MS")
        field(LNK3, "MCOR:EXT:211:LATCHED_FAULTSTATE PP MS")
        field(LNK4, "MCOR:EXT:212:LATCHED_FAULTSTATE PP MS")
        field(LNK5, "MCOR:EXT:213:LATCHED_FAULTSTATE PP MS")
        field(LNK6, "MCOR:EXT:214:LATCHED_FAULTSTATE PP MS")
        field(LNK7, "MCOR:EXT:215:LATCHED_FAULTSTATE PP MS")
        field(LNK8, "MCOR:EXT:216:LATCHED_FAULTSTATE PP MS")
        field(ASG, "Internal")
}

##################################################
# External Interlocks 0-3 Soft Channels
##################################################
record(mbbiDirect,   "MCOR:EXT:200:EXT_INTLK_STATE") {
	field(DESC,  "External Interlock Status")
        field(NOBT,  "16")
	field(INP,   "MCOR:EXT:200:EXT_INTLK_R")
        field(FLNK,  "MCOR:EXT:200:EXT_INTLK1_STATE")
}

record(bi, "MCOR:EXT:200:EXT_INTLK1_STATE") {
  field(DESC, "External Interlock 1 Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:EXT_INTLK_STATE.B0 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:EXT_INTLK2_STATE")
}
record(bi, "MCOR:EXT:200:EXT_INTLK2_STATE") {
  field(DESC, "External Interlock 2 Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:EXT_INTLK_STATE.B1 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:EXT_INTLK3_STATE")
}
record(bi, "MCOR:EXT:200:EXT_INTLK3_STATE") {
  field(DESC, "External Interlock 3 Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:EXT_INTLK_STATE.B2 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
}


##################################################
# Water Flow Software Fault Status Soft Channels
# not implemented
#
# A = water flow in gallons/minute
# B = water flow lower limit
# C = water flow pv severity
##################################################
# This PV is not implemented yet. Not sure if we neede this extra PV.
record(calcout, "MCOR:EXT:200:FLOW_FAULTSTATE_CALC") {
        field(DESC, "Check if water flow is restricted")
        field(PINI, "YES")
        field(ASG,  "Internal")
        field(CALC, "(C=3)||(A>B)?0:1")
        field(INPA, "")
        field(INPB, "")
        field(INPC, "")
        field(OOPT,  "Every Time")
#        field(OUT,  "MCOR:EXT:200:FLOW_FAULTSTATE PP")
}

record(bi, "MCOR:EXT:200:FLOW_FAULTSTATE") {
	field(DESC, "Water Flow Software Fault Status")
	field(INP,  "MCOR:EXT:200:MAGNET8_STATE")
        field(ZNAM, "OK")
        field(ONAM, "FAULTED")
        field(OSV,  "MAJOR")
        field(FLNK, "MCOR:EXT:200:FLOW_FAULTSTATE_SEQ.PROC")
}

record(seq, "MCOR:EXT:200:FLOW_FAULTSTATE_SEQ") {
        field(DESC,  "Water Flow Fault Status sequence")
        field(ASG,   "Internal")
        field(DOL1,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(DOL2,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(DOL3,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(DOL4,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(DOL5,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(DOL6,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(DOL7,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(DOL8,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(LNK1,  "MCOR:EXT:201:FLOW_FAULTSTATE_CALC PP MS")
        field(LNK2,  "MCOR:EXT:202:FLOW_FAULTSTATE_CALC PP MS")
        field(LNK3,  "MCOR:EXT:203:FLOW_FAULTSTATE_CALC PP MS")
        field(LNK4,  "MCOR:EXT:204:FLOW_FAULTSTATE_CALC PP MS")
        field(LNK5,  "MCOR:EXT:205:FLOW_FAULTSTATE_CALC PP MS")
        field(LNK6,  "MCOR:EXT:206:FLOW_FAULTSTATE_CALC PP MS")
        field(LNK7,  "MCOR:EXT:207:FLOW_FAULTSTATE_CALC PP MS")
        field(LNK8,  "MCOR:EXT:208:FLOW_FAULTSTATE_CALC PP MS")
        field(FLNK,  "MCOR:EXT:200:FLOW_FAULTSTATE_SEQ_2")
}

record(seq, "MCOR:EXT:200:FLOW_FAULTSTATE_SEQ_2") {
        field(DESC, "Water Flow Fault Status fanout")
        field(ASG, "Internal")
        field(DOL1,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(DOL2,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(DOL3,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(DOL4,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(DOL5,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(DOL6,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(DOL7,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(DOL8,  "MCOR:EXT:200:FLOW_FAULTSTATE")
        field(LNK1, "MCOR:EXT:209:FLOW_FAULTSTATE_CALC PP MS")
        field(LNK2, "MCOR:EXT:210:FLOW_FAULTSTATE_CALC PP MS")
        field(LNK3, "MCOR:EXT:211:FLOW_FAULTSTATE_CALC PP MS")
        field(LNK4, "MCOR:EXT:212:FLOW_FAULTSTATE_CALC PP MS")
        field(LNK5, "MCOR:EXT:213:FLOW_FAULTSTATE_CALC PP MS")
        field(LNK6, "MCOR:EXT:214:FLOW_FAULTSTATE_CALC PP MS")
        field(LNK7, "MCOR:EXT:215:FLOW_FAULTSTATE_CALC PP MS")
        field(LNK8, "MCOR:EXT:216:FLOW_FAULTSTATE_CALC PP MS")
        field(FLNK, "MCOR:EXT:200:PS_TRIP_CALC")
}

# If no flow fault then do nothing. Otherwise, if water fault
# and the ps is on then turn off the ps.
record(calcout, "MCOR:EXT:200:PS_TRIP_CALC") {
       field(DESC, "Check if PS should be tripped")
       field(ASG,  "Internal")
       field(CALC, "A&&B?1:0")
       field(INPA, "MCOR:EXT:200:FLOW_FAULTSTATE")
       field(INPB, "LGPS:EXT:1:STATE")
       field(OOPT, "When Non-zero")
       field(OUT,  "MCOR:EXT:200:PS_TRIP_SEQ PP")
}

record(seq, "MCOR:EXT:200:PS_TRIP_SEQ") {
	field(DESC, "PS Trip Sequence")
	field(ASG,  "Internal")
	field(SELM, "Specified")
	field(LNK1, "LGPS:EXT:1:FUNC PP")
        field(DOL1, "10")
}


# Reset External Interlocks 0-3
record(bo, "MCOR:EXT:200:EXT_INTLK0_RESET") {
        field(DESC, "External Interlock 0 Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:EXT_INTLK0_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:EXT_INTLK0_RESET_SEQ") {
        field(DESC,"External Interlock 0 Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "1")
        field(DOL2,  "1")
# Delay the processing of LNK2 for DLY seconds
        field(DLY2,  "0.4")
        field(LNK1, "MCOR:EXT:200:EXT_INTLK_S PP")
        field(LNK2, "MCOR:EXT:200:EXT_INTLK_C PP")
}


record(bo, "MCOR:EXT:200:EXT_INTLK1_RESET") {
        field(DESC, "External Interlock 1 Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:EXT_INTLK1_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:EXT_INTLK1_RESET_SEQ") {
        field(DESC,"External Interlock 1 Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "2")
        field(DOL2,  "2")
# Delay the processing of LNK2 for DLY seconds
        field(DLY2,  "0.4")
        field(LNK1, "MCOR:EXT:200:EXT_INTLK_S PP")
        field(LNK2, "MCOR:EXT:200:EXT_INTLK_C PP")
        field(ASG, "Internal")
}

record(bo, "MCOR:EXT:200:EXT_INTLK2_RESET") {
        field(DESC, "External Interlock 2 Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:EXT_INTLK2_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:EXT_INTLK2_RESET_SEQ") {
        field(DESC,"External Interlock 2 Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "4")
        field(DOL2,  "4")
# Delay the processing of LNK2 for DLY seconds
        field(DLY2,  "0.4")
        field(LNK1, "MCOR:EXT:200:EXT_INTLK_S PP")
        field(LNK2, "MCOR:EXT:200:EXT_INTLK_C PP")
        field(ASG, "Internal")
}

record(bo, "MCOR:EXT:200:EXT_INTLK3_RESET") {
        field(DESC, "External Interlock 3 Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:EXT_INTLK3_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:EXT_INTLK3_RESET_SEQ") {
        field(DESC,"External Interlock 3 Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "8")
        field(DOL2,  "8")
# Delay the processing of LNK2 for DLY seconds
        field(DLY2,  "0.4")
        field(LNK1, "MCOR:EXT:200:EXT_INTLK_S PP")
        field(LNK2, "MCOR:EXT:200:EXT_INTLK_C PP")
        field(ASG, "Internal")
}

################################################################
# Magnet 0-7 Fault and Water Flow Summary Fault Status Soft Channels
################################################################
record(mbbiDirect,   "MCOR:EXT:200:MAGNET_STATE") {
	field(DESC,  "Magnet Fault State")
        field(NOBT,  "16")
	field(INP,   "MCOR:EXT:200:MAGNET_FAULT_R")
        field(FLNK,  "MCOR:EXT:200:MAGNET0_STATE")
}

record(bi, "MCOR:EXT:200:MAGNET0_STATE") {
  field(DESC, "Magnet 0 Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B0 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:MAGNET1_STATE")
}
record(bi, "MCOR:EXT:200:MAGNET1_STATE") {
  field(DESC, "Magnet 1 Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B1 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:MAGNET2_STATE")
}
record(bi, "MCOR:EXT:200:MAGNET2_STATE") {
  field(DESC, "Magnet 2 Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B2 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:MAGNET3_STATE")
}
record(bi, "MCOR:EXT:200:MAGNET3_STATE") {
  field(DESC, "Magnet 3 Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B3 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:MAGNET4_STATE")
}
record(bi, "MCOR:EXT:200:MAGNET4_STATE") {
  field(DESC, "Magnet 4 Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B4")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:MAGNET5_STATE")
}
record(bi, "MCOR:EXT:200:MAGNET5_STATE") {
  field(DESC, "Magnet 5 Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B5 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:MAGNET6_STATE")
}
record(bi, "MCOR:EXT:200:MAGNET6_STATE") {
  field(DESC, "Magnet 6 Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B6 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:MAGNET7_STATE")
}
record(bi, "MCOR:EXT:200:MAGNET7_STATE") {
  field(DESC, "Magnet 7 Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B7 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:MAGNET8_STATE")
}


# Water flow switch summary fault or Klixon (temp) summary fault
# Which type of fault depeneds on the type signal  connected in the field.
record(bi, "MCOR:EXT:200:MAGNET8_STATE") {
  field(DESC, "Magnet 8 Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:MAGNET_STATE.B8 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:200:MAGNET_STATSUMY_CALC")
}

record(calc, "MCOR:EXT:200:MAGNET_STATSUMY_CALC") {
  field(DESC, "Magnet 0-7 Summary Status")
  field(CALC, "A|B|C|D|E|F|G|H?1:0")
  field(INPA, "MCOR:EXT:200:MAGNET0_STATE NPP MS")
  field(INPB, "MCOR:EXT:200:MAGNET1_STATE NPP MS")
  field(INPC, "MCOR:EXT:200:MAGNET2_STATE NPP MS")
  field(INPD, "MCOR:EXT:200:MAGNET3_STATE NPP MS")
  field(INPE, "MCOR:EXT:200:MAGNET4_STATE NPP MS")
  field(INPF, "MCOR:EXT:200:MAGNET5_STATE NPP MS")
  field(INPG, "MCOR:EXT:200:MAGNET6_STATE NPP MS")
  field(INPH, "MCOR:EXT:200:MAGNET7_STATE NPP MS")
  field(FLNK, "MCOR:EXT:200:MAGNET_STATSUMY")
}
record(bi, "MCOR:EXT:200:MAGNET_STATSUMY") {
  field(DESC, "Magnet 0-7 Summary Status")
  field(INP,  "MCOR:EXT:200:MAGNET_STATSUMY_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:200:FLOW_FAULTSTATE")
}


# Latched Magnet Fault Status Soft Channels
record(mbbiDirect,   "MCOR:EXT:200:LATCHED_MAGNET_STATE") {
  field(DESC,  "Latched Magnet Fault State")
  field(NOBT,  "16")
  field(INP,   "MCOR:EXT:200:LATCHED_MAGNET_FAULT_R")
  field(FLNK,  "MCOR:EXT:200:LATCHED_MAGNET0_STATE")
}

record(bi, "MCOR:EXT:200:LATCHED_MAGNET0_STATE") {
  field(DESC, "Latched Magnet 0 Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B0 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:LATCHED_MAGNET1_STATE")
}
record(bi, "MCOR:EXT:200:LATCHED_MAGNET1_STATE") {
  field(DESC, "Latched Magnet 1 Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B1 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:LATCHED_MAGNET2_STATE")
}
record(bi, "MCOR:EXT:200:LATCHED_MAGNET2_STATE") {
  field(DESC, "Latched Magnet 2 Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B2 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")

  field(FLNK, "MCOR:EXT:200:LATCHED_MAGNET3_STATE")
}
record(bi, "MCOR:EXT:200:LATCHED_MAGNET3_STATE") {
  field(DESC, "Latched Magnet 3 Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B3 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:LATCHED_MAGNET4_STATE")
}
record(bi, "MCOR:EXT:200:LATCHED_MAGNET4_STATE") {
  field(DESC, "Latched Magnet 4 Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B4 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:LATCHED_MAGNET5_STATE")
}
record(bi, "MCOR:EXT:200:LATCHED_MAGNET5_STATE") {
  field(DESC, "Latched Magnet 5 Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B5 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:LATCHED_MAGNET6_STATE")
}
record(bi, "MCOR:EXT:200:LATCHED_MAGNET6_STATE") {
  field(DESC, "Latched Magnet 6 Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B6 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:LATCHED_MAGNET7_STATE")
}
record(bi, "MCOR:EXT:200:LATCHED_MAGNET7_STATE") {
  field(DESC, "Latched Magnet 7 Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B7 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
  field(FLNK, "MCOR:EXT:200:LATCHED_MAGNET8_STATE")
}

# latched Water flow switch summary fault or Klixon (temp) summary fault
# Which type of fault depeneds on the type signal  connected in the field.
record(bi, "MCOR:EXT:200:LATCHED_MAGNET8_STATE") {
  field(DESC, "Latched Magnet 8 Fault Status")
  field(DTYP, "Soft Channel")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATE.B8 NPP MS")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV,  "MAJOR")
  field(FLNK, "MCOR:EXT:200:LATCHED_MAGNET_STATSUMY_CALC")
}

record(calc, "MCOR:EXT:200:LATCHED_MAGNET_STATSUMY_CALC") {
  field(DESC, "Latched Magnet 0-7 Summary Status")
  field(CALC, "A|B|C|D|E|F|G|H?1:0")
  field(INPA, "MCOR:EXT:200:LATCHED_MAGNET0_STATE NPP MS")
  field(INPB, "MCOR:EXT:200:LATCHED_MAGNET1_STATE NPP MS")
  field(INPC, "MCOR:EXT:200:LATCHED_MAGNET2_STATE NPP MS")
  field(INPD, "MCOR:EXT:200:LATCHED_MAGNET3_STATE NPP MS")
  field(INPE, "MCOR:EXT:200:LATCHED_MAGNET4_STATE NPP MS")
  field(INPF, "MCOR:EXT:200:LATCHED_MAGNET5_STATE NPP MS")
  field(INPG, "MCOR:EXT:200:LATCHED_MAGNET6_STATE NPP MS")
  field(INPH, "MCOR:EXT:200:LATCHED_MAGNET7_STATE NPP MS")
  field(FLNK, "MCOR:EXT:200:LATCHED_MAGNET_STATSUMY")
}
record(bi, "MCOR:EXT:200:LATCHED_MAGNET_STATSUMY") {
  field(DESC, "Latched Magnet 0-7 Summary Status")
  field(INP,  "MCOR:EXT:200:LATCHED_MAGNET_STATSUMY_CALC")
  field(ZNAM, "OK")
  field(ONAM, "FAULTED")
  field(OSV, "MAJOR")
}

# Reset Magnet 0-7 Faults and Water Fault Summary
record(bo, "MCOR:EXT:200:MAGNET0_RESET") {
        field(DESC, "Magnet 0 Fault Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:MAGNET0_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:MAGNET0_RESET_SEQ") {
        field(DESC,"Magnet 0 Fault Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "1")
        field(LNK2, "MCOR:EXT:200:MAGNET_FAULT_C PP")
        field(ASG, "Internal")
}

record(bo, "MCOR:EXT:200:MAGNET1_RESET") {
        field(DESC, "Magnet 1 Fault Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:MAGNET1_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:MAGNET1_RESET_SEQ") {
        field(DESC,"Magnet 1 Fault Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "2")
        field(LNK1, "MCOR:EXT:200:MAGNET_FAULT_C PP")
        field(ASG, "Internal")
}

record(bo, "MCOR:EXT:200:MAGNET2_RESET") {
        field(DESC, "Magnet 2 Fault Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:MAGNET2_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:MAGNET2_RESET_SEQ") {
        field(DESC,"Magnet 2 Fault Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "4")
        field(LNK1, "MCOR:EXT:200:MAGNET_FAULT_C PP")
        field(ASG, "Internal")
}

record(bo, "MCOR:EXT:200:MAGNET2_RESET") {
        field(DESC, "Magnet 3 Fault Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:MAGNET3_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:MAGNET3_RESET_SEQ") {
        field(DESC,"Magnet 3 Fault Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "8")
        field(LNK1, "MCOR:EXT:200:MAGNET_FAULT_C PP")
        field(ASG, "Internal")
}

record(bo, "MCOR:EXT:200:MAGNET4_RESET") {
        field(DESC, "Magnet 4 Fault Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:MAGNET4_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:MAGNET4_RESET_SEQ") {
        field(DESC,"Magnet 4 Fault Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "16")
        field(LNK1, "MCOR:EXT:200:MAGNET_FAULT_C PP")
        field(ASG, "Internal")
}

record(bo, "MCOR:EXT:200:MAGNET5_RESET") {
        field(DESC, "Magnet 5 Fault Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:MAGNET5_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:MAGNET5_RESET_SEQ") {
        field(DESC,"Magnet 5 Fault Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "32")
        field(LNK1, "MCOR:EXT:200:MAGNET_FAULT_C PP")
        field(ASG, "Internal")
}

record(bo, "MCOR:EXT:200:MAGNET6_RESET") {
        field(DESC, "Magnet 6 Fault Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:MAGNET6_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:MAGNET6_RESET_SEQ") {
        field(DESC,"Magnet 6 Fault Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "64")
        field(LNK1, "MCOR:EXT:200:MAGNET_FAULT_C PP")
        field(ASG, "Internal")
}

record(bo, "MCOR:EXT:200:MAGNET7_RESET") {
        field(DESC, "Magnet 7 Fault Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:MAGNET7_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:MAGNET7_RESET_SEQ") {
        field(DESC,"Magnet 7 Fault Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "128")
        field(LNK1, "MCOR:EXT:200:MAGNET_FAULT_C PP")
        field(ASG, "Internal")
}
record(bo, "MCOR:EXT:200:MAGNET8_RESET") {
        field(DESC, "Magnet 8 Fault Reset")
        field(DTYP, "Soft Channel")
        field(ZNAM, "Reset")
        field(ONAM, "Reset")
        field(FLNK, "MCOR:EXT:200:MAGNET8_RESET_SEQ")
}
record(seq, "MCOR:EXT:200:MAGNET8_RESET_SEQ") {
        field(DESC,"Magnet 8 Fault Reset seq")
        field(ASG, "Internal")
        field(DOL1,  "256")
        field(LNK1, "MCOR:EXT:200:MAGNET_FAULT_C PP")
        field(ASG, "Internal")
}

#################################################################
# Xilinx System Monitor

record(longin, "MCOR:EXT:200:CHIP_TEMP_R") {
	field(DESC, "Xilinx Crate 2 Temp")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x580,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CHIP_TEMP.A")
}

record(longin, "MCOR:EXT:200:CHIP_VCC_INT_R") {
	field(DESC, "Xilinx Crate 2 Volt")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x584,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CHIP_VCC_INT.A")
}

record(longin, "MCOR:EXT:200:CHIP_VCC_AUX_R") {
	field(DESC, "Xilinx Crate 2 Volt Aux")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x588,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CHIP_VCC_AUX.A")
}

record(longin, "MCOR:EXT:200:CHIP_TEMP_MAX_R") {
	field(DESC, "Xilinx Crate 2 Temp Max")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x58c,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CHIP_TEMP_MAX.A")
}

record(longin, "MCOR:EXT:200:CHIP_VCC_INT_MAX_R") {
	field(DESC, "Xilinx 2 V(Int) Volt Max")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x590,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CHIP_VCC_INT_MAX.A")
}

record(longin, "MCOR:EXT:200:CHIP_VCC_AUX_MAX_R") {
	field(DESC, "Xilinx Crate 2 Volt Max")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x594,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CHIP_VCC_AUX_MAX.A")
}

record(longin, "MCOR:EXT:200:CHIP_TEMP_MIN_R") {
	field(DESC, "Xilinx Crate 2 Temp Mix")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x598,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CHIP_TEMP_MIN.A")
}

record(longin, "MCOR:EXT:200:CHIP_VCC_INT_MIN_R") {
	field(DESC, "Xilinx Crate 2 V(Int) Volt Min")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x59c,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CHIP_VCC_INT_MIN.A")
}

record(longin, "MCOR:EXT:200:CHIP_VCC_AUX_MIN_R") {
	field(DESC, "Xilinx Crate 2 Volt Mix")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x5a0,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CHIP_VCC_AUX_MIN.A")
}

#################################################################
# Crate Voltages

record(longin, "MCOR:EXT:200:CRATE_V15_R") {
	field(DESC, "Crate 2 +15V")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x540,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CRATE_V15.A")
        field(ASG, "Internal")
}

record(longin, "MCOR:EXT:200:CRATE_V12_R") {
	field(DESC, "Crate 2 +12V")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x544,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CRATE_V12.A")
        field(ASG, "Internal")
}

record(longin, "MCOR:EXT:200:CRATE_V5_R") {
	field(DESC, "Crate 2 +5V")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x548,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CRATE_V5.A")
        field(ASG, "Internal")
}

record(longin, "MCOR:EXT:200:CRATE_V3_3_R") {
	field(DESC, "Crate 2 +3.3V")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x54c,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CRATE_V3_3.A")
        field(ASG, "Internal")
}

record(longin, "MCOR:EXT:200:CRATE_V3_3VCC_R") {
	field(DESC, "Crate 2 +3.3VCC")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x550,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CRATE_V3_3VCC.A")
        field(ASG, "Internal")
}

record(longin, "MCOR:EXT:200:CRATE_V15NEG_R") {
	field(DESC, "Crate 2 -15V")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x554,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CRATE_V15NEG.A")
        field(ASG, "Internal")
}

#################################################################
# Crate Currents

record(longin, "MCOR:EXT:200:CRATE_I15_R") {
	field(DESC, "Crate 2 +15V Current")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x558,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CRATE_I15.A")
        field(ASG, "Internal")
}

record(longin, "MCOR:EXT:200:CRATE_I12_R") {
	field(DESC, "Crate 2 +12V Current")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x55c,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CRATE_I12.A")
        field(ASG, "Internal")
}


record(longin, "MCOR:EXT:200:CRATE_I5_R") {
	field(DESC, "Crate 2 +5V Current")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x560,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CRATE_I5.A")
        field(ASG, "Internal")
}

record(longin, "MCOR:EXT:200:CRATE_I3_3_R") {
	field(DESC, "Crate 2 +3.3V Current")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x564,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CRATE_I3_3.A")
        field(ASG, "Internal")
}

record(longin, "MCOR:EXT:200:CRATE_I3_3VCC_R") {
	field(DESC, "Crate 2 +3.3VCC Current")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x568,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CRATE_I3_3VCC.A")
        field(ASG, "Internal")
}

record(longin, "MCOR:EXT:200:CRATE_I2_5_R") {
	field(DESC, "Crate 2 +2.5V Current")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x56c,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CRATE_I2_5.A")
        field(ASG, "Internal")
}

record(longin, "MCOR:EXT:200:CRATE_I1_R") {
	field(DESC, "Crate 2 +1.0V Current")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x570,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CRATE_I1.A")
        field(ASG, "Internal")
}

record(longin, "MCOR:EXT:200:CRATE_I15NEG_R") {
	field(DESC, "Crate 2 -15V Current")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x574,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CRATE_I15NEG.A")
        field(ASG, "Internal")
}

#################################################################
# Board temperature

record(longin, "MCOR:EXT:200:CRATE_TEMP_R") {
	field(DESC, "Crate 2 Temp")
	field(DTYP, "BusAddress")
	field(INP,  "#C0S6@mcor0.0+0x578,le32")
	field(SCAN, "10 second")
        field(EGU,  "Counts")
        field(FLNK, "MCOR:EXT:200:CRATE_TEMP.A")
        field(ASG, "Internal")
}

######################################
# Bulk Power Supply  PVs (Soft PVs)

record(bo,   "MCOR:EXT:200:PS_STATE") {
	field(DESC,  "Bulk PS On/Off State")
	field(DOL,   "LGPS:EXT:1:STATE CPP MS")
        field(OMSL,  "closed_loop")
        field(ZNAM,  "OFF")
        field(ONAM,  "ON")
        field(FLNK,  "MCOR:EXT:200:PS_STATE_SEQ.PROC")
}
record(dfanout, "MCOR:EXT:200:PS_STATE_SEQ") {
        field(DESC, "Bulk PS On/Off State fanout")
        field(ASG,  "Internal")
        field(DOL,  "MCOR:EXT:200:PS_STATE MS")
        field(OMSL, "closed_loop")
        field(OUTA, "MCOR:EXT:201:STATE_CALC.A PP")
        field(OUTB, "MCOR:EXT:202:STATE_CALC.A PP")
        field(OUTC, "MCOR:EXT:203:STATE_CALC.A PP")
        field(OUTD, "MCOR:EXT:204:STATE_CALC.A PP")
        field(OUTE, "MCOR:EXT:205:STATE_CALC.A PP")
        field(OUTF, "MCOR:EXT:206:STATE_CALC.A PP")
        field(OUTG, "MCOR:EXT:207:STATE_CALC.A PP")
        field(OUTH, "MCOR:EXT:208:STATE_CALC.A PP")
        field(FLNK, "MCOR:EXT:200:PS_STATE_SEQ_2.PROC")
}
record(dfanout, "MCOR:EXT:200:PS_STATE_SEQ_2") {
        field(DESC, "Bulk PS On/Off State fanout")
        field(ASG,  "Internal")
        field(DOL,  "MCOR:EXT:200:PS_STATE MS")
        field(OMSL, "closed_loop")
        field(OUTA, "MCOR:EXT:209:STATE_CALC.A PP")
        field(OUTB, "MCOR:EXT:210:STATE_CALC.A PP")
        field(OUTC, "MCOR:EXT:211:STATE_CALC.A PP")
        field(OUTD, "MCOR:EXT:212:STATE_CALC.A PP")
        field(OUTE, "MCOR:EXT:213:STATE_CALC.A PP")
        field(OUTF, "MCOR:EXT:214:STATE_CALC.A PP")
        field(OUTG, "MCOR:EXT:215:STATE_CALC.A PP")
        field(OUTH, "MCOR:EXT:216:STATE_CALC.A PP")
        field(FLNK, "MCOR:EXT:200:FaultStateCheck")
}

# When the power supply is turned on reset any faults.
record(calcout, "MCOR:EXT:200:FaultStateCheck") {
        field(DESC,  "Reset faults when PS turned On")
        field(ASG,   "Internal")
        field(CALC,  "A&&B&&(C=0)?1:0")
        field(OOPT,  "Transition To Non-zero")
        field(INPA,  "MCOR:EXT:200:PS_STATE NPP MS")
        field(INPB,  "MCOR:EXT:200:FAULTSTATE NPP NMS")
        field(INPC,  "MCOR:EXT:200:FaultStateCheck.LA")
        field(OUT,   "MCOR:EXT:200:RESET PP")
}

record(bo,   "MCOR:EXT:200:PS_TURNEDOFF") {
	field(DESC,  "Bulk PS Turned Off by User")
	field(DOL,   "LGPS:EXT:1:TURNEDOFF CPP MS")
        field(OMSL,  "closed_loop")
        field(PINI,  "YES")
        field(ZNAM,  "NO")
        field(ONAM,  "YES")
        field(FLNK,  "MCOR:EXT:200:PS_TURNEDOFF_SEQ.PROC")
}
record(dfanout, "MCOR:EXT:200:PS_TURNEDOFF_SEQ") {
        field(DESC, "PS Turned Off Fanout")
        field(ASG,  "Internal")
        field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF")
        field(OMSL, "closed_loop")
        field(OUTA, "MCOR:EXT:201:TURNEDOFF PP")
        field(OUTB, "MCOR:EXT:202:TURNEDOFF PP")
        field(OUTC, "MCOR:EXT:203:TURNEDOFF PP")
        field(OUTD, "MCOR:EXT:204:TURNEDOFF PP")
        field(OUTE, "MCOR:EXT:205:TURNEDOFF PP")
        field(OUTF, "MCOR:EXT:206:TURNEDOFF PP")
        field(OUTG, "MCOR:EXT:207:TURNEDOFF PP")
        field(OUTH, "MCOR:EXT:208:TURNEDOFF PP")
        field(FLNK, "MCOR:EXT:200:PS_TURNEDOFF_SEQ_2.PROC")
}
record(dfanout, "MCOR:EXT:200:PS_TURNEDOFF_SEQ_2") {
        field(DESC, "PS Turned Off Fanout")
        field(ASG,  "Internal")
        field(DOL,  "MCOR:EXT:200:PS_TURNEDOFF")
        field(OMSL, "closed_loop")
        field(OUTA, "MCOR:EXT:209:TURNEDOFF PP")
        field(OUTB, "MCOR:EXT:210:TURNEDOFF PP")
        field(OUTC, "MCOR:EXT:211:TURNEDOFF PP")
        field(OUTD, "MCOR:EXT:212:TURNEDOFF PP")
        field(OUTE, "MCOR:EXT:213:TURNEDOFF PP")
        field(OUTF, "MCOR:EXT:214:TURNEDOFF PP")
        field(OUTG, "MCOR:EXT:215:TURNEDOFF PP")
        field(OUTH, "MCOR:EXT:216:TURNEDOFF PP")
}

######################################
# Crate Voltages (Sof PVs)

record(calc, "MCOR:EXT:200:CRATE_V15") {
  field(DESC, "Crate 2 +15V")
  field(CALC, "A*B*C")
  field(INPA, "MCOR:EXT:200:CRATE_V15_R")
  field(B,    "6.0")
  field(INPC, "305.18e-6")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_V12") {
  field(DESC, "Crate 2 +12V")
  field(CALC, "A*B*C")
  field(INPA, "MCOR:EXT:200:CRATE_V12_R")
  field(B,    "4.83")
  field(C,    "305.18e-6")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_V5") {
  field(DESC, "Crate 2 +5V")
  field(CALC, "A*B*C")
  field(INPA, "MCOR:EXT:200:CRATE_V5_R")
  field(B,    "2.0")
  field(C,    "305.18e-6")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_V3_3") {
  field(DESC, "Crate 2 +3.3V")
  field(CALC, "A*C")
  field(INPA, "MCOR:EXT:200:CRATE_V3_3_R")
  field(C,    "305.18e-6")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_V3_3VCC") {
  field(DESC, "Crate 2 +3.3VCC")
  field(CALC, "A*C")
  field(INPA, "MCOR:EXT:200:CRATE_V3_3VCC_R")
  field(C,    "305.18e-6")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_V15NEG") {
  field(DESC, "Crate 2 -15V")
  field(CALC, "A*B*C")
  field(INPA, "MCOR:EXT:200:CRATE_V15NEG_R")
  field(B,     "-16.0")
  field(C,    "305.18e-6")
  field(EGU,  "V")
  field(PREC, "4")
}

# Crate Current (Soft PVs)
record(calc, "MCOR:EXT:200:CRATE_I15") {
  field(DESC, "Crate 2 +15V")
  field(CALC, "(A*B)/C")
  field(INPA, "MCOR:EXT:200:CRATE_I15_R")
  field(B,    "19.0735e-6")
  field(C,    "60.0e-3")
  field(EGU,  "A")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_I12") {
  field(DESC, "Crate 2 +12V Current")
  field(CALC, "(A*B)/C")
  field(INPA, "MCOR:EXT:200:CRATE_I12_R")
  field(B,    "19.0735e-6")
  field(C,    "150.0e-3")
  field(EGU,  "A")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_I5") {
  field(DESC, "Crate 2 +5V Current")
  field(CALC, "(A*B)/C")
  field(INPA, "MCOR:EXT:200:CRATE_I5_R")
  field(B,    "19.0735e-6")
  field(C,    "30.0e-3")
  field(EGU,  "A")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_I3_3") {
  field(DESC, "Crate 2 +3.3V Current")
  field(CALC, "(A*B)/C")
  field(INPA, "MCOR:EXT:200:CRATE_I3_3_R")
  field(B,    "19.0735e-6")
  field(C,    "150.0e-3")
  field(EGU,  "A")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_I3_3VCC") {
  field(DESC, "Crate 2 +3.3VCC Current")
  field(CALC, "(A*B)/C")
  field(INPA, "MCOR:EXT:200:CRATE_I3_3VCC_R")
  field(B,    "19.0735e-6")
  field(C,    "150.0e-3")
  field(EGU,  "A")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_I2_5") {
  field(DESC, "Crate 2 +2.5V Current")
  field(CALC, "(A*B)/C")
  field(INPA, "MCOR:EXT:200:CRATE_I2_5_R")
  field(B,    "19.0735e-6")
  field(C,    "150.0e-3")
  field(EGU,  "A")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_I1") {
  field(DESC, "Crate 2 +1V Current")
  field(CALC, "(A*B)/C")
  field(INPA, "MCOR:EXT:200:CRATE_I1_R")
  field(B,    "19.0735e-6")
  field(C,    "150.0e-3")
  field(EGU,  "A")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_I15NEG") {
  field(DESC, "Crate 2 -15V Current")
  field(CALC, "(A*B)/C")
  field(INPA, "MCOR:EXT:200:CRATE_I15NEG_R")
  field(B,    "19.0735e-6")
  field(C,    "60.0e-3")
  field(EGU,  "A")
  field(PREC, "4")
}

#################################################################
# Crate Power

record(calc, "MCOR:EXT:200:CRATE_V15_PWR") {
  field(DESC, "Crate 2 +15V Power")
  field(SCAN, "10 second")
  field(CALC, "A*B")
  field(INPA, "MCOR:EXT:200:CRATE_I15")
  field(INPB, "MCOR:EXT:200:CRATE_V15")
  field(EGU,  "Watts")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_V12_PWR") {
  field(DESC, "Crate 2 +12V Power")
  field(SCAN, "10 second")
  field(CALC, "A*B")
  field(INPA, "MCOR:EXT:200:CRATE_I12")
  field(INPB, "MCOR:EXT:200:CRATE_V12")
  field(EGU,  "Watts")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_V5_PWR") {
  field(DESC, "Crate 2 +5V Power")
  field(SCAN, "10 second")
  field(CALC, "A*B")
  field(INPA, "MCOR:EXT:200:CRATE_I5")
  field(INPB, "MCOR:EXT:200:CRATE_V5")
  field(EGU,  "Watts")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_V3_3_PWR") {
  field(DESC, "Crate 2 +3.3V Power")
  field(SCAN, "10 second")
  field(CALC, "A*B")
  field(INPA, "MCOR:EXT:200:CRATE_I3_3")
  field(INPB, "MCOR:EXT:200:CRATE_V3_3")
  field(EGU,  "Watts")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_V3_3VCC_PWR") {
  field(DESC, "Crate 2 +3.3VCC Power")
  field(SCAN, "10 second")
  field(CALC, "A*B")
  field(INPA, "MCOR:EXT:200:CRATE_I3_3VCC")
  field(INPB, "MCOR:EXT:200:CRATE_V3_3VCC")
  field(EGU,  "Watts")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_V2_5_PWR") {
  field(DESC, "Crate 2 +2.5V Power")
  field(SCAN, "10 second")
  field(CALC, "A*B")
  field(INPA, "MCOR:EXT:200:CRATE_I2_5")
  field(INPB, "MCOR:EXT:200:CHIP_VCC_AUX")
  field(EGU,  "Watts")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_V1_PWR") {
  field(DESC, "Crate 2 +1V Power")
  field(SCAN, "10 second")
  field(CALC, "A*B")
  field(INPA, "MCOR:EXT:200:CRATE_I1")
  field(INPB, "MCOR:EXT:200:CHIP_VCC_INT")
  field(EGU,  "Watts")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_V15NEG_PWR") {
  field(DESC, "Crate 2 -15V Power")
  field(SCAN, "10 second")
  field(CALC, "A*B")
  field(INPA, "MCOR:EXT:200:CRATE_I15NEG")
  field(INPB, "MCOR:EXT:200:CRATE_V15NEG")
  field(EGU,  "Watts")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_PWR") {
  field(DESC, "Crate 2 Total Power")
  field(SCAN, "10 second")
  field(CALC, "A+B+C+D+E+F+G+H")
  field(INPA, "MCOR:EXT:200:CRATE_V15_PWR NPP MS")
  field(INPB, "MCOR:EXT:200:CRATE_V12_PWR NPP MS")
  field(INPC, "MCOR:EXT:200:CRATE_V5_PWR NPP MS NPP MS")
  field(INPD, "MCOR:EXT:200:CRATE_V3_3_PWR NPP MS")
  field(INPE, "MCOR:EXT:200:CRATE_V3_3VCC_PWR NPP MS")
  field(INPF, "MCOR:EXT:200:CRATE_V15NEG_PWR NPP MS")
  field(INPG, "MCOR:EXT:200:CRATE_V2_5_PWR NPP MS")
  field(INPH, "MCOR:EXT:200:CRATE_V1_PWR NPP MS")
  field(EGU,  "Watts")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CRATE_V_STATSUMY") {
  field(DESC, "Crate 2 Voltage")
  field(SCAN, "10 second")
  field(INPA, "MCOR:EXT:200:CRATE_V15.SEVR NPP MS")
  field(INPB, "MCOR:EXT:200:CRATE_V12.SEVR NPP MS")
  field(INPC, "MCOR:EXT:200:CRATE_V5.SEVR NPP MS")
  field(INPD, "MCOR:EXT:200:CRATE_V3_3.SEVR NPP MS")
  field(INPE, "MCOR:EXT:200:CRATE_V15NEG.SEVR NPP MS")
}

record(calc, "MCOR:EXT:200:CRATE_I_STATSUMY") {
  field(DESC, "Crate 2 Current")
  field(SCAN, "10 second")
  field(INPA, "MCOR:EXT:200:CRATE_I15.SEVR NPP MS")
  field(INPB, "MCOR:EXT:200:CRATE_I12.SEVR NPP MS")
  field(INPC, "MCOR:EXT:200:CRATE_I5.SEVR NPP MS")
  field(INPD, "MCOR:EXT:200:CRATE_I3_3.SEVR NPP MS")
  field(INPD, "MCOR:EXT:200:CRATE_I1.SEVR NPP MS")
  field(INPE, "MCOR:EXT:200:CRATE_V15NEG.SEVR NPP MS")
}


record(calc, "MCOR:EXT:200:CRATE_PWR_STATSUMY") {
  field(DESC, "Crate 2 Total Power")
  field(SCAN, "10 second")
  field(INPA, "MCOR:EXT:200:CRATE_V15_PWR.SEVR NPP MS")
  field(INPB, "MCOR:EXT:200:CRATE_V12_PWR.SEVR NPP MS")
  field(INPC, "MCOR:EXT:200:CRATE_V5_PWR.SEVR NPP MS NPP MS")
  field(INPD, "MCOR:EXT:200:CRATE_V3_3_PWR.SEVR NPP MS")
  field(INPE, "MCOR:EXT:200:CRATE_V3_3VCC_PWR.SEVR NPP MS")
  field(INPF, "MCOR:EXT:200:CRATE_V15NEG_PWR.SEVR NPP MS")
  field(INPG, "MCOR:EXT:200:CRATE_V2_5_PWR.SEVR NPP MS")
  field(INPH, "MCOR:EXT:200:CRATE_V1_PWR.SEVR NPP MS")
  field(INPI, "MCOR:EXT:200:CRATE_V15NEG_PWR.SEVR NPP MS")
}


record(calc, "MCOR:EXT:200:CRATE_STATSUMY") {
  field(SCAN, "10 second")
  field(CALC, "A||B||C?1:0")
  field(INPA, "MCOR:EXT:200:CRATE_TEMP.SEVR MS")
  field(INPB, "MCOR:EXT:200:CRATE_V_STATSUMY.SEVR NPP MS")
  field(INPB, "MCOR:EXT:200:CRATE_I_STATSUMY.SEVR NPP MS")
  field(INPC, "MCOR:EXT:200:CRATE_PWR_STATSUMY.SEVR MS")
  field(INPD, "MCOR:EXT:200:CHIP_STATSUMY.SEVR MS")
}

#################################################################
# Borad temperature

record(calc, "MCOR:EXT:200:CRATE_TEMP") {
  field(DESC, "Crate 2 Temp")
  field(CALC, "A*B")
  field(INPA, "MCOR:EXT:200:CRATE_TEMP_R")
  field(B,    "0.0625")
  field(EGU,  "C")
  field(PREC, "4")
  field(FLNK, "MCOR:EXT:200:CRATE_TEMP_DEGF")
}

record(calc, "MCOR:EXT:200:CRATE_TEMP_DEGF") {
  field(DESC, "Crate 2 Temp")
  field(CALC, "(A*1.8)+32")
  field(INPA, "MCOR:EXT:200:CRATE_TEMP")
  field(EGU,  "F")
  field(PREC, "4")
}

#################################################################
# Xilinx System Monitor (Soft PVs)

record(calc, "MCOR:EXT:200:CHIP_STATSUMY") {
  field(SCAN, "10 second")
  field(INPA, "MCOR:EXT:200:CHIP_TEMP.SEVR MS")
  field(INPB, "MCOR:EXT:200:CHIP_VCC_INT.SEVR MS")
  field(INPC, "MCOR:EXT:200:CHIP_VCC_AUX.SEVR MS")
  field(INPD, "MCOR:EXT:200:CHIP_TEMP_MAX.SEVR MS")
  field(INPE, "MCOR:EXT:200:CHIP_VCC_INT_MAX.SEVR MS")
  field(INPF, "MCOR:EXT:200:CHIP_VCC_AUX_MAX.SEVR MS")
  field(INPG, "MCOR:EXT:200:CHIP_VCC_INT_MIN.SEVR MS")
  field(INPH, "MCOR:EXT:200:CHIP_VCC_AUX_MIN.SEVR MS")
  field(INPI, "MCOR:EXT:200:CHIP_TEMP_MIN.SEVR MS")
}


record(calc, "MCOR:EXT:200:CHIP_TEMP") {
  field(DESC, "Xilinx 2 Temp")
  field(CALC, "((A/64)*(503.975/1024))-273.15")
  field(INPA, "MCOR:EXT:200:CHIP_TEMP_R")
  field(EGU,  "C")
  field(PREC, "4")
  field(FLNK, "MCOR:EXT:200:CHIP_TEMP_DEGF.A")
}

record(calc, "MCOR:EXT:200:CHIP_TEMP_DEGF") {
  field(DESC, "Xilinx 2 Temp")
  field(CALC, "(A*1.8)+32")
  field(INPA, "MCOR:EXT:200:CHIP_TEMP")
  field(EGU,  "F")
  field(PREC, "4")
}


record(calc, "MCOR:EXT:200:CHIP_VCC_INT") {
  field(DESC, "Xilinx 2 Volt")
  field(CALC, "((A/64)/1024)*3")
  field(INPA, "MCOR:EXT:200:CHIP_VCC_INT_R")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CHIP_VCC_AUX") {
  field(DESC, "Xilinx 2 Volt")
  field(CALC, "((A/64)/1024)*3")
  field(INPA, "MCOR:EXT:200:CHIP_VCC_AUX_R")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CHIP_TEMP_MAX") {
  field(DESC, "Xilinx 2 Max Temp")
  field(CALC, "((A/64)*(503.975/1024))-273.15")
  field(INPA, "MCOR:EXT:200:CHIP_TEMP_MAX_R")
  field(EGU,  "C")
  field(PREC, "4")
  field(FLNK, "MCOR:EXT:200:CHIP_TEMP_MAX_DEGF.A")
}

record(calc, "MCOR:EXT:200:CHIP_TEMP_MAX_DEGF") {
  field(DESC, "Xilinx 2 Max Temp")
  field(CALC, "(A*1.8)+32")
  field(INPA, "MCOR:EXT:200:CHIP_TEMP_MAX")
  field(EGU,  "F")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CHIP_VCC_INT_MAX") {
  field(DESC, "Xilinx 2 Volt")
  field(CALC, "((A/64)/1024)*3")
  field(INPA, "MCOR:EXT:200:CHIP_VCC_INT_MAX_R")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CHIP_VCC_AUX_MAX") {
  field(DESC, "Xilinx 2 Volt")
  field(CALC, "((A/64)/1024)*3")
  field(INPA, "MCOR:EXT:200:CHIP_VCC_AUX_MAX_R")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CHIP_VCC_INT_MIN") {
  field(DESC, "Xilinx 2 Volt")
  field(CALC, "((A/64)/1024)*3")
  field(INPA, "MCOR:EXT:200:CHIP_VCC_INT_MIN_R.PROC")
  field(EGU,  "V")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CHIP_TEMP_MIN") {
  field(DESC, "Xilinx 2 Min Temp")
  field(CALC, "((A/64)*(503.975/1024))-273.15")
  field(INPA, "MCOR:EXT:200:CHIP_TEMP_MIN_R")
  field(EGU,  "C")
  field(PREC, "4")
  field(FLNK, "MCOR:EXT:200:CHIP_TEMP_MIN_DEGF.A")
}

record(calc, "MCOR:EXT:200:CHIP_TEMP_MIN_DEGF") {
  field(DESC, "Xilinx 2 Min Temp")
  field(CALC, "(A*1.8)+32")
  field(INPA, "MCOR:EXT:200:CHIP_TEMP_MIN")
  field(EGU,  "F")
  field(PREC, "4")
}

record(calc, "MCOR:EXT:200:CHIP_VCC_AUX_MIN") {
  field(DESC, "Xilinx 2 Min Volt")
  field(CALC, "((A/64)/1024)*3")
  field(INPA, "MCOR:EXT:200:CHIP_VCC_AUX_MIN_R")
  field(EGU,  "V")
  field(PREC, "4")
}

#################################################################
#  Full scale voltage ranges

# Full scale DAC voltage range
record(ao,  "MCOR:EXT:200:VRANGE_DAC") {
 field(DESC, "Full Scale DAC Voltage Range")
 field(PINI, "YES")
 field(EGU,  "V")
 field(PREC, "6")
 field(DOL,  "10.2564")
 field(OMSL, "closed_loop")
}

# Full scale ADC voltage range
record(ao,  "MCOR:EXT:200:VRANGE_ADC") {
 field(DESC, "Full Scale ADC Voltage Range")
 field(PINI, "YES")
 field(EGU,  "V")
 field(PREC, "6")
 field(DOL,  "10.0")
 field(OMSL, "closed_loop")
}

# DAC and FBCK Full scale range
record(ao,  "MCOR:EXT:200:VRANGE_FBCK") {
 field(DESC, "Full Scale FBCK Voltage Range")
 field(PINI, "YES")
 field(EGU,  "V")
 field(PREC, "6")
 field(DOL,  "10.0")
 field(OMSL, "closed_loop")
}

#################################################################
# Generic information

record(longout, "MCOR:EXT:200:CRATE") {
  field(DESC, "Crate Number")
  field(DTYP, "Soft Channel")
  field(HOPR, "10")
  field(LOPR, "1")
  field(DRVH, "10")
  field(DRVL, "1")
  field(PINI, "YES")
  field(VAL, "2")
}

record(stringout, "MCOR:EXT:200:TYPE") {
  field(DESC, "MCOR Crate")
  field(PINI, "YES")
  field(VAL, "BiRa MCOR Crate Model 2513")
}

record(stringout, "MCOR:EXT:200:LOCATION") {
  field(DESC, "Rack Location")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL, "L2KG08-5620")
}

record(stringout, "MCOR:EXT:200:DRAWING") {
  field(DESC, "SODA Drawing No.")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(VAL,  "CAPTAR")
}