record(stringin, "APC:$(LOCA):100:LOCATION") { field(VAL, "$(LOC)") field(PINI, "YES") } record(longin, "APC:$(LOCA):100:CPLRCOUTWDS") { field(DESC, "Complex output words") field(SCAN, "10 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:COWCNT") } record(longin, "APC:$(LOCA):100:CPLRCINWDS") { field(DESC, "Complex input words") field(SCAN, "10 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:CIWCNT") } record(longin, "APC:$(LOCA):100:CPLRDOUTBITS") { field(DESC, "Digital output bits") field(SCAN, "10 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:DOBCNT") } record(longin, "APC:$(LOCA):100:CPLRDINBITS") { field(DESC, "Digital input bits") field(SCAN, "10 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:DIBCNT") } record(longin, "APC:$(LOCA):100:CPLRNOFCONN") { field(DESC, "Nth of Connection") field(SCAN, "10 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:NOFCONN") } record(longin, "APC:$(LOCA):100:CPLRNOFEXCP") { field(DESC, "Nth of Exception") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:NOFEXCP") } record(longin, "APC:$(LOCA):100:CPLRNOFPKTS") { field(DESC, "Number of Packets Sent") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:NOFPKTS") } record(longin, "APC:$(LOCA):100:CPLRNOFSIGS") { field(DESC, "Number of Signals of CPLR") field(SCAN, "Passive") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:NOFSIGS") } record(longin, "APC:$(LOCA):100:CPLROPTHRDID") { field(DESC, "Op thread ID") field(SCAN, "Passive") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:OPTHRDID") } record(mbbi, "APC:$(LOCA):100:CPLRREADY") { field(DESC, "Is Coupler Ready") field(SCAN, "1 second") field(PINI, "YES") field(PHAS, "2") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:CPLRRDY") field(ZRVL, "0") field(ONVL, "1") field(ZRST, "Not Ready") field(ONST, "Ready") field(ZRSV, "MAJOR") field(ONSV, "NO_ALARM") field(SHFT, "0") field(UNSV, "INVALID") field(FLNK, "APC:$(LOCA):100:CPLRREPROCCALC") } record(calcout, "APC:$(LOCA):100:CPLRREPROCCALC") { field(SCAN, "Passive") field(CALC, "A") field(INPA, "APC:$(LOCA):100:CPLRREADY") field(INPB, "APC:$(LOCA):100:CPLRREPROCCALC.VAL") field(OUT, "APC:$(LOCA):100:CPLRREPROCFOUT.SELN") field(FLNK, "APC:$(LOCA):100:CPLRREPROCFOUT") field(OCAL, "((A=1)&&(B#1))?1:0") field(VAL, "1") field(DESC, "Calc reprocess") field(OOPT, "Every Time") field(DOPT, "Use OCAL") field(PINI, "NO") } record(fanout, "APC:$(LOCA):100:CPLRREPROCFOUT") { field(DESC, "FANOUT Reproc") field(SCAN, "Passive") field(SELM, "Mask") field(LNK1, "APC:$(LOCA):100:OUTPUTREPROCEVT") field(PINI, "NO") field(SELN, "") } record(event, "APC:$(LOCA):100:OUTPUTREPROCEVT") { field(DESC, "Post event to reproc") field(SCAN, "Passive") field(VAL, "0") } record(mbbi, "APC:$(LOCA):100:CPLRLINKSTAT") { field(DESC, "Coupler MBT Link Stat") field(SCAN, "1 second") field(PINI, "YES") field(PHAS, "2") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:LINKSTAT") field(ZRVL, "0") field(ONVL, "1") field(TWVL, "2") field(THVL, "3") field(ZRST, "Link Down") field(ONST, "Link OK") field(TWST, "Connecting") field(THST, "Unsupported") field(SHFT, "0") field(UNSV, "INVALID") } record(stringin, "APC:$(LOCA):100:CPLRNAME") { field(DESC, "Name of Coupler") field(SCAN, "Passive") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:CPLRNAME") } record(stringin, "APC:$(LOCA):100:CPLRIPADDR") { field(DESC, "IPAddr of Coupler") field(SCAN, "Passive") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:CPLRIP") } record(stringin, "APC:$(LOCA):100:CPLRTLOSTCONN") { field(DESC, "Time of lost connection") field(SCAN, "10 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:TLSTCONN") } record(stringin, "APC:$(LOCA):100:CPLRTSETCONN") { field(DESC, "Time of set connection") field(SCAN, "10 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:TSETCONN") } record(stringin, "APC:$(LOCA):100:CPLRTLASTTRY") { field(DESC, "Time of last try connect") field(SCAN, "10 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:TLASTTRY") } record(stringin, "APC:$(LOCA):100:CPLRID") { field(DESC, "ID of Coupler") field(SCAN, "10 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:CPLRID") } record(stringin, "APC:$(LOCA):100:CPLROPTHRDNAME") { field(DESC, "Op Thread Name of Coupler") field(SCAN, "Passive") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):0:OPTHRDNM") } record(longin, "APC:$(LOCA):100:CPLRBTSLOT1") { field(DESC, "Bus Terminal Type of slot 1") field(SCAN, "10 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):1:BTTYPE") } record(longin, "APC:$(LOCA):100:CPLRBTSLOT2") { field(DESC, "Bus Terminal Type of slot 2") field(SCAN, "10 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):2:BTTYPE") } record(longin, "APC:$(LOCA):100:CPLRBTSLOT3") { field(DESC, "Bus Terminal Type of slot 3") field(SCAN, "10 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):3:BTTYPE") } record(longin, "APC:$(LOCA):100:CPLRBTSLOT4") { field(DESC, "Bus Terminal Type of slot 4") field(SCAN, "10 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):4:BTTYPE") } record(longin, "APC:$(LOCA):100:CPLRBTSLOT5") { field(DESC, "Bus Terminal Type of slot 5") field(SCAN, "10 second") field(PINI, "YES") field(DTYP, "Bk9000_Info") field(INP, "@$(NODE):5:BTTYPE") } record(bi, "APC:$(LOCA):100:M1_CH1_SIG") { field(DESC, "Digital Channel 1 Readback") #Need to scan faster than 1 Hz to avoid bad watchdog state? field(SCAN, ".1 second") field(DTYP, "Bk9000_KL1104") field(INP, "@$(NODE):1:R_DIG_IN_1") field(ZNAM, "ON") field(ONAM, "OFF") field(FLNK, "APC:$(LOCA):100:M1_CH1_CALC") info(autosaveFields, "DESC ZNAM ONAM ZSV OSV") } record(calc, "APC:$(LOCA):100:M1_CH1_CALC") { field(DESC, "Swap the state pv") field(CALC, "A?0:1") field(INPA, "APC:$(LOCA):100:M1_CH1_SIG") field(FLNK, "$(DEV1):STATE") } record(bi, "$(DEV1):STATE") { field(DESC, "Y PS On/Off Status") field(INP, "APC:$(LOCA):100:M1_CH1_CALC") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(COSV, "NO_ALARM") field(FLNK, "$(MDEV1)STATE NPP MS") info(autosaveFields, "DESC ZNAM ONAM ZSV OSV COSV") } record(bi, "APC:$(LOCA):100:M1_CH2_SIG") { field(DESC, "Digital Channel 2 Readback") #Need to scan faster than 1 Hz to avoid bad watchdog state? field(SCAN, ".1 second") field(DTYP, "Bk9000_KL1104") field(INP, "@$(NODE):1:R_DIG_IN_2") field(ZNAM, "ON") field(ONAM, "OFF") field(FLNK, "APC:$(LOCA):100:M1_CH2_CALC") info(autosaveFields, "DESC ZNAM ONAM ZSV OSV") } record(calc, "APC:$(LOCA):100:M1_CH2_CALC") { field(DESC, "Swap the state pv") field(CALC, "A?0:1") field(INPA, "APC:$(LOCA):100:M1_CH2_SIG") field(FLNK, "$(DEV2):STATE") } record(bi, "$(DEV2):STATE") { field(DESC, "X PS On/Off Status") field(INP, "APC:$(LOCA):100:M1_CH2_CALC") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(COSV, "NO_ALARM") field(FLNK, "$(MDEV2)STATE NPP MS") info(autosaveFields, "DESC ZNAM ONAM ZSV OSV COSV") } record(bo, "$(DEV1):STATESETPT") { field(DESC, "Y PS On/Off Ctl") field(OMSL, "supervisory") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(FLNK, "APC:$(LOCA):100:M2_CH1_SIG") field(VAL, "0") field(PINI, "YES") field(HIGH, "0") info(autosaveFields, "VAL DESC ZNAM ONAM ZSV OSV HIGH") } record(bo, "APC:$(LOCA):100:M2_CH1_SIG") { field(DESC, "Digital Channel 1 Set") field(DTYP, "Bk9000_KL2114") field(OUT, "@$(NODE):2:W_DIG_OUT_1") field(DOL, "$(DEV1):STATESETPT") field(OMSL, "closed_loop") field(ZNAM, "OFF") field(ONAM, "ON") info(autosaveFields, "VAL DESC ZNAM ONAM ZSV OSV HIGH") } # These BCS outputs are only initiated by user. Do not # want to process on reconnect. #record(fanout, "APC:$(LOCA):100:M2_CH1_OUT_REPROC") { # field(DESC, "Process on reconnect") # field(SCAN, "Event") # field(EVNT, "$(REPROCEVT)") # field(SELM, "All") # field(LNK1, "APC:$(LOCA):100:M2_CH1_IN") # field(PINI, "NO") #} record(bo, "$(DEV2):STATESETPT") { field(DESC, "X PS On/Off Ctl") field(OMSL, "supervisory") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(FLNK, "APC:$(LOCA):100:M2_CH2_SIG") field(VAL, "0") field(PINI, "YES") field(HIGH, "0") info(autosaveFields, "VAL DESC ZNAM ONAM ZSV OSV HIGH") } record(bo, "APC:$(LOCA):100:M2_CH2_SIG") { field(DESC, "Digital Channel 2 Set") field(DTYP, "Bk9000_KL2114") field(OUT, "@$(NODE):2:W_DIG_OUT_2") field(DOL, "$(DEV2):STATESETPT") field(OMSL, "closed_loop") field(ZNAM, "OFF") field(ONAM, "ON") info(autosaveFields, "VAL DESC ZNAM ONAM ZSV OSV HIGH") } # These BCS outputs are only initiated by user. Do not # want to process on reconnect. #record(fanout, "APC:$(LOCA):100:M2_CH2_OUT_REPROC") { # field(DESC, "Process on reconnect") # field(SCAN, "Event") # field(EVNT, "$(REPROCEVT)") # field(SELM, "All") # field(LNK1, "APC:$(LOCA):100:M2_CH2_IN") # field(PINI, "NO") #} # to be used with analog-conversion-lcls.template record(ai, "APC:$(LOCA):100:M3_CH1_SIG") { field(DESC, "Analog Ch1 Readback") field(SCAN, "1 second") field(DTYP, "Bk9000_KL3162") field(INP, "@$(NODE):3:R_ANA_IN_1") field(PREC, "3") field(ADEL, "") field(EGUF, "10") field(EGUL, "0") field(HIGH, "0") field(HIHI, "0") field(HOPR, "10") field(HYST, "") field(LOLO, "0") field(LOPR, "0") field(LOW, "0") field(MDEL, "-1") # field(SMOO, "") field(EGU, "V") field(HHSV, "NO_ALARM") field(LLSV, "NO_ALARM") field(HSV, "NO_ALARM") field(LSV, "NO_ALARM") field(LINR, "LINEAR") field(FLNK, "$(DEV1):VACT") # alias("") } # to be used with analog-conversion-lcls.template record(ai, "APC:$(LOCA):100:M3_CH2_SIG") { field(DESC, "Analog Ch2 Readback") field(SCAN, "1 second") field(DTYP, "Bk9000_KL3162") field(INP, "@$(NODE):3:R_ANA_IN_2") field(PREC, "3") field(ADEL, "") field(EGUF, "10") field(EGUL, "0") field(HIGH, "0") field(HIHI, "0") field(HOPR, "10") field(HYST, "") field(LOLO, "0") field(LOPR, "0") field(LOW, "0") field(MDEL, "-1") # field(SMOO, "") field(EGU, "V") field(HHSV, "NO_ALARM") field(LLSV, "NO_ALARM") field(HSV, "NO_ALARM") field(LSV, "NO_ALARM") field(LINR, "LINEAR") field(FLNK, "$(DEV2):VACT") # alias("") } record(ao, "APC:$(LOCA):100:M4_CH1_SIG") { field(DESC, "Analog Channel 1 Set") field(DTYP, "Bk9000_KL4002") field(OUT, "@$(NODE):4:W_ANA_OUT_1") field(DOL, "$(DEV1):VSETPT") field(OMSL, "supervisory") field(PREC, "3") field(EGUF, "10") field(EGUL, "0") field(DRVH, "10.0") field(DRVL, "0") field(HOPR, "10") field(LOPR, "0") field(EGU, "V") field(PINI, "NO") field(LINR, "LINEAR") info(autosaveFields,"VAL") # alias("") } record(ao, "APC:$(LOCA):100:M4_CH2_SIG") { field(DESC, "Analog Channel 2 Set") field(DTYP, "Bk9000_KL4002") field(OUT, "@$(NODE):4:W_ANA_OUT_2") field(DOL, "$(DEV2):VSETPT") field(OMSL, "supervisory") field(PREC, "3") field(EGUF, "10") field(EGUL, "0") field(DRVH, "10.0") field(DRVL, "0") field(HOPR, "10") field(LOPR, "0") field(EGU, "V") field(PINI, "NO") field(LINR, "LINEAR") info(autosaveFields,"VAL") # alias("") } #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../../dbd/mgnt.dbd") #! DBDEND ###### Calculate Voltage from Current ####### record(ao, "$(DEV1):ISETPT") { field(DESC, "Y PS Current Setpoint") field(PREC, "6") field(HOPR, "5000") field(DRVH, "5000") field(ESLO, "") field(EOFF, "0") field(EGU, "V") field(OMSL, "supervisory") field(DOL, "$(MDEV1)ISETPT") field(FLNK, "$(DEV1):I2VDES") } # Use calc records instead of ao for or ai record to convert # from amps to volts and visa-versa. The calc record has the # the input/output fields defined as a double. Whereas the ao # output RVAL is a long and the ai input field is a short. # record(calcout, "$(DEV1):I2VDES") { field(DESC, "Ch 1 Voltage Setpoint") field(CALC, "B=0?0:(C-A)/B") field(INPA, "$(DEV1):POLYCOEF.A") field(INPB, "$(DEV1):POLYCOEF.B") field(INPC, "$(DEV1):ISETPT") field(EGU, "V") field(PREC, "6") field(HOPR, "10.0") field(OUT, "$(DEV1):VSETPT PP") } record(ao, "$(DEV1):VSETPT") { field(DESC, "PS Voltages Setpt") field(PREC, 6) field(DRVH, "10.0") field(EGU, "V") field(OUT, "APC:$(LOCA):100:M4_CH1_SIG PP") } record(ai, "$(DEV1):VACT") { field(DESC, "Acutual Voltage") field(HOPR, "10") field(PREC, "6") field(INP, "APC:$(LOCA):100:M3_CH1_SIG NPP MS") field(EGU, "V") field(FLNK, "$(DEV1):VOUT") } ###### Calculate Current from Voltage ####### # Use calc records instead of ao for or ai record to convert # from amps to volts and visa-versa. The calc record has the # the input/output fields defined as a double. Whereas the ao # output RVAL is a long and the ai input field is a short. # record(calc, "$(DEV1):IACT") { field(DESC, "Y PS Actual Current") field(CALC, "(C*B)+A") field(INPA, "$(DEV1):POLYCOEF.A") field(INPB, "$(DEV1):POLYCOEF.B") field(INPC, "$(DEV1):VACT NPP MS") field(EGU, "V") field(PREC, "6") field(HOPR, "5000") field(FLNK, "$(MDEV1)IACT") } # ===== Fake Pvs ======= record(ai, "$(DEV1):VOUT") { field(DESC, "Voltage Readback") field(HOPR, "10") field(PREC, "6") field(INP, "$(DEV1):VACT NPP MS") field(EGU, "V") field(FLNK, "$(DEV1):IACT") } record(bo, "$(DEV1):INTLKSUMY") { field(DESC, "PS interlock status") field(PINI, "YES") field(ZNAM, "OK") field(ONAM, "FAULT") field(OSV, "MAJOR") field(VAL, "0") field(OUT, "$(MDEV1)INTLKSUMY PP NMS") } record(bo, "$(DEV1):RESET") { field(DESC, "Reset Interlock Latch") field(DTYP, "Raw Soft Channel") field(ZNAM, "RESET") field(ONAM, "NORESET") field(HIGH, "1.0") field(DOL, "$(MDEV1)RESET.RVAL") field(OMSL, "supervisory") } #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../../dbd/mgnt.dbd") #! DBDEND ###### Calculate Voltage from Current ####### record(ao, "$(DEV2):ISETPT") { field(DESC, "X PS Current Setpoint") field(PREC, "6") field(HOPR, "5000") field(DRVH, "5000") field(ESLO, "") field(EOFF, "0") field(EGU, "V") field(OMSL, "supervisory") field(DOL, "$(MDEV2)ISETPT") field(FLNK, "$(DEV2):I2VDES") } # Use calc records instead of ao for or ai record to convert # from amps to volts and visa-versa. The calc record has the # the input/output fields defined as a double. Whereas the ao # output RVAL is a long and the ai input field is a short. # record(calcout, "$(DEV2):I2VDES") { field(DESC, "Ch 2 Voltage Setpoint") field(CALC, "B=0?0:(C-A)/B") field(INPA, "$(DEV2):POLYCOEF.A") field(INPB, "$(DEV2):POLYCOEF.B") field(INPC, "$(DEV2):ISETPT") field(EGU, "V") field(PREC, "6") field(HOPR, "10.0") field(OUT, "$(DEV2):VSETPT PP") } record(ao, "$(DEV2):VSETPT") { field(DESC, "PS Voltages Setpt") field(PREC, 6) field(DRVH, "10.0") field(EGU, "V") field(OUT, "APC:$(LOCA):100:M4_CH2_SIG PP") } record(ai, "$(DEV2):VACT") { field(DESC, "Acutual Voltage") field(HOPR, "10") field(PREC, "6") field(INP, "APC:$(LOCA):100:M3_CH2_SIG NPP MS") field(EGU, "V") field(FLNK, "$(DEV2):VOUT") } ###### Calculate Current from Voltage ####### # Use calc records instead of ao for or ai record to convert # from amps to volts and visa-versa. The calc record has the # the input/output fields defined as a double. Whereas the ao # output RVAL is a long and the ai input field is a short. # record(calc, "$(DEV2):IACT") { field(DESC, "X PS Actual Current") field(CALC, "(C*B)+A") field(INPA, "$(DEV2):POLYCOEF.A") field(INPB, "$(DEV2):POLYCOEF.B") field(INPC, "$(DEV2):VACT NPP MS") field(EGU, "V") field(PREC, "6") field(HOPR, "5000") field(FLNK, "$(MDEV2)IACT") } # ===== Fake Pvs ======= record(ai, "$(DEV2):VOUT") { field(DESC, "Voltage Readback") field(HOPR, "10") field(PREC, "6") field(INP, "$(DEV2):VACT NPP MS") field(EGU, "V") field(FLNK, "$(DEV2):IACT") } record(bo, "$(DEV2):INTLKSUMY") { field(DESC, "PS interlock status") field(PINI, "YES") field(ZNAM, "OK") field(ONAM, "FAULT") field(OSV, "MAJOR") field(VAL, "0") field(OUT, "$(MDEV2)INTLKSUMY PP NMS") } record(bo, "$(DEV2):RESET") { field(DESC, "Reset Interlock Latch") field(DTYP, "Raw Soft Channel") field(ZNAM, "RESET") field(ONAM, "NORESET") field(HIGH, "1.0") field(DOL, "$(MDEV2)RESET.RVAL") field(OMSL, "supervisory") } #! Generated by VisualDCT v2.5 #! DBDSTART #! DBD("../../../dbd/mgntSoft.dbd") #! DBDEND # Generic information record(stringout, "$(DEV1):LOCATION") { field(DESC, "Rack Location") field(PINI, "YES") field(DTYP, "Soft Channel") field(VAL, "$(LOC)") } record(stringout, "$(DEV1):DRAWING") { field(DESC, "SODA Drawing No.") field(PINI, "YES") field(DTYP, "Soft Channel") field(VAL, "Unknown") } record(bo, "$(DEV1):RAMPSTATE") { field(DESC, "PS ramp status") field(OUT, "$(MDEV1)RAMPSTATE PP") field(ZNAM, "OFF") field(ONAM, "BUSY") field(PINI, "YES") field(VAL, "0") } record(mbbo, "$(DEV1):COOLING") { field(DESC, "Type of cooling") field(NOBT, "2") field(ZRST, "AIR") field(ONST, "WATER") field(TWST, "HELIUM") field(THST, "NONE") field(ZRVL, "0") field(ONVL, "1") field(TWVL, "2") field(THVL, "3") field(PINI, "YES") field(OUT, "$(MDEV1)COOLING PP") field(VAL, "0") } #! Generated by VisualDCT v2.5 #! DBDSTART #! DBD("../../../dbd/mgntSoft.dbd") #! DBDEND # Generic information record(stringout, "$(DEV2):LOCATION") { field(DESC, "Rack Location") field(PINI, "YES") field(DTYP, "Soft Channel") field(VAL, "$(LOC)") } record(stringout, "$(DEV2):DRAWING") { field(DESC, "SODA Drawing No.") field(PINI, "YES") field(DTYP, "Soft Channel") field(VAL, "Unknown") } record(bo, "$(DEV2):RAMPSTATE") { field(DESC, "PS ramp status") field(OUT, "$(MDEV2)RAMPSTATE PP") field(ZNAM, "OFF") field(ONAM, "BUSY") field(PINI, "YES") field(VAL, "0") } record(mbbo, "$(DEV2):COOLING") { field(DESC, "Type of cooling") field(NOBT, "2") field(ZRST, "AIR") field(ONST, "WATER") field(TWST, "HELIUM") field(THST, "NONE") field(ZRVL, "0") field(ONVL, "1") field(TWVL, "2") field(THVL, "3") field(PINI, "YES") field(OUT, "$(MDEV2)COOLING PP") field(VAL, "0") }