[mboyes@lcls-dev2:2011-10-31-a]$ ../../scripts/version1-0-5/mpsconfigpatch.py MPSDatabase.mps HXRSS_MPS_Patch_File.json The following devices will be added: 31 2 1 VVMG UND1 1645 OPEN_LMTSW STATE NOT_OPEN OPEN 1 open switch 31 2 2 VVMG UND1 1655 OPEN_LMTSW STATE NOT_OPEN OPEN 1 open switch 31 2 3 BMLN UND1 1650 IN_LMTSW STATE IS_NOT_IN IS_IN 1 closed switch, summary status of all hardware switches 31 2 4 BMLN UND1 1650 OUT_LMTSW STATE IS_NOT_OUT IS_OUT 1 open switch, summary status of all hardware switches 31 2 6 XTAL UND1 1650 OUT_LMTSW STATE IS_NOT_OUT IS_OUT 1 Crystal Out Switch (Home Switch) 31 2 7 BEND UND1 1640 OFF STATE IS_NOT_OFF IS_OFF 1 HXRSS chicane magnet string on 31 2 8 BEND UND1 1640 ON STATE IS_NOT_ON IS_ON 1 HXRSS chicane magnet string on 11 4 14 XTAL UND1 1650 POSITIONSTAT STATE IS_NOT_VALID IS_VALID 1 Crystal position is known and is valid 11 6 9 XTAL UND1 1650 IN_ENCDR STATE IS_NOT_IN IS_IN 1 Encoder In Status; In when > +1.5mm 11 4 15 BEND DMP1 400 HXRSS_INTOL STATE IS_NOT_OK IS_OK 1 Beam Energy within HXRSS range; 12.7 GeV < E < 14.2 GeV 11 5 7 BEND UND1 1640 INTOL STATE IS_FAULTED IS_OK 1 HXRSS chicane bend magnet string in tol, must be > +0.6 kG-m Adding new Link Node Card 31.2 to database Adding new Link Node Channel 31.2.1 to database Check if already in ZFAULT: ZDEVICE=VVMG_UND1_1645_OPEN_LMTSW and ZNAME=STATE Not found, so adding PV Fault"VVMG_UND1_1645_OPEN_LMTSW" STATE Added Channel 31 2 1 -- VVMG_UND1_1645_OPEN_LMTSW STATE Adding new Link Node Channel 31.2.2 to database Check if already in ZFAULT: ZDEVICE=VVMG_UND1_1655_OPEN_LMTSW and ZNAME=STATE Not found, so adding PV Fault"VVMG_UND1_1655_OPEN_LMTSW" STATE Added Channel 31 2 2 -- VVMG_UND1_1655_OPEN_LMTSW STATE Adding new Link Node Channel 31.2.3 to database Adding new PV Device Type "BMLN" to database Check if already in ZFAULT: ZDEVICE=BMLN_UND1_1650_IN_LMTSW and ZNAME=STATE Not found, so adding PV Fault"BMLN_UND1_1650_IN_LMTSW" STATE Added Channel 31 2 3 -- BMLN_UND1_1650_IN_LMTSW STATE Adding new Link Node Channel 31.2.4 to database Check if already in ZFAULT: ZDEVICE=BMLN_UND1_1650_OUT_LMTSW and ZNAME=STATE Not found, so adding PV Fault"BMLN_UND1_1650_OUT_LMTSW" STATE Added Channel 31 2 4 -- BMLN_UND1_1650_OUT_LMTSW STATE Adding new Link Node Channel 31.2.6 to database Adding new PV Device Type "XTAL" to database Check if already in ZFAULT: ZDEVICE=XTAL_UND1_1650_OUT_LMTSW and ZNAME=STATE Not found, so adding PV Fault"XTAL_UND1_1650_OUT_LMTSW" STATE Added Channel 31 2 6 -- XTAL_UND1_1650_OUT_LMTSW STATE Adding new Link Node Channel 31.2.7 to database Check if already in ZFAULT: ZDEVICE=BEND_UND1_1640_OFF and ZNAME=STATE Not found, so adding PV Fault"BEND_UND1_1640_OFF" STATE Added Channel 31 2 7 -- BEND_UND1_1640_OFF STATE Adding new Link Node Channel 31.2.8 to database Check if already in ZFAULT: ZDEVICE=BEND_UND1_1640_ON and ZNAME=STATE Not found, so adding PV Fault"BEND_UND1_1640_ON" STATE Added Channel 31 2 8 -- BEND_UND1_1640_ON STATE Check if already in ZFAULT: ZDEVICE=XTAL_UND1_1650_POSITIONSTAT and ZNAME=STATE Not found, so adding PV Fault"XTAL_UND1_1650_POSITIONSTAT" STATE Added Channel 11 4 14 -- XTAL_UND1_1650_POSITIONSTAT STATE Check if already in ZFAULT: ZDEVICE=XTAL_UND1_1650_IN_ENCDR and ZNAME=STATE Not found, so adding PV Fault"XTAL_UND1_1650_IN_ENCDR" STATE Added Channel 11 6 9 -- XTAL_UND1_1650_IN_ENCDR STATE Check if already in ZFAULT: ZDEVICE=BEND_DMP1_400_HXRSS_INTOL and ZNAME=STATE Not found, so adding PV Fault"BEND_DMP1_400_HXRSS_INTOL" STATE Added Channel 11 4 15 -- BEND_DMP1_400_HXRSS_INTOL STATE Check if already in ZFAULT: ZDEVICE=BEND_UND1_1640_INTOL and ZNAME=STATE Not found, so adding PV Fault"BEND_UND1_1640_INTOL" STATE Added Channel 11 5 7 -- BEND_UND1_1640_INTOL STATE [mboyes@lcls-dev2:2011-10-31-a]$ [mboyes@lcls-dev2:2011-10-31-a]$ [mboyes@lcls-dev2:2011-10-31-a]$ [mboyes@lcls-dev2:2011-10-31-a]$ [mboyes@lcls-dev2:2011-10-31-a]$ ../../scripts/version1-0-5/mpsconfigpatch.py MPSDatabase.mps ALine_MPS_Patch_File.json The following devices will be added: RTD:BSYA:2060:PASTSL10SUM RTD BSYA 2060 PASTSL10SUM STATUS IS_FAULTED IS_OK 1 A-Line Past SL10 RTD Summary Adding new External PV "RTD:BSYA:2060:PASTSL10SUM" to database Check if already in ZFAULT: ZDEVICE=RTD_BSYA_2060_PASTSL10SUM and ZNAME=STATUS Not found, so adding PV Fault"RTD_BSYA_2060_PASTSL10SUM" STATUS Added External PV RTD:BSYA:2060:PASTSL10SUM -- RTD_BSYA_2060_PASTSL10SUM STATUS