Cleaned up logic for FEE1 M1S Mirror Beam Energy Upper Limit. Simplified logic to utilize a single limit switch and depend on FEE1 M1S Mirror State to catch inconsistencies in mirror position. sdiff -bs 2014-02-21-a/doc/MPSLogicDocumentation.txt 2014-02-06-a/doc/MPSLogicDocumentation.txt .. title:: MPS Logic 2014-02-21-a | .. title:: MPS Logic 2014-02-06-a ===== = = ==================== ==================== ========= | ========================================= = = = ============= Name B A Pockels Cell Mechanical Shutter BY | Name C B A Pockels C ===== = = ==================== ==================== ========= | ========================================= = = = ============= Fault F F 0 Hz 0 Hz | Fault F F F OK F T 120 Hz 120 Hz | Limit switch inconsistent F F T OK T F 120 Hz 120 Hz | Limit switch inconsistent F T F OK T T 120 Hz 120 Hz | OK F T T ===== = = ==================== ==================== ========= | OK T F F > Energy safe but limit switch inconsistent T F T > Energy safe but limit switch inconsistent T T F > OK T T T > ========================================= = = = ============= B = MIRR_FEE1_1560_ENERGY_STATE | B = MIRR_FEE1_1560_OUT_LIMIT2_POSITION > C = MIRR_FEE1_1560_ENERGY_STATE Not Out F F 120 Hz 120 Hz | Not Out F F 120 Hz 120 Hz Inconsistent F T 0 Hz 0 Hz | Inconsistent F T 0 Hz 0 Hz Inconsistent T F 0 Hz 0 Hz | Inconsistent T F 0 Hz 0 Hz Out T T 120 Hz 120 Hz | Out T T 120 Hz 120 Hz