record(ai, "PMTR:LT10:20:PWR") { field(DESC, "Power meter laser steering") field(SCAN, "I/O Intr") field(DTYP, "IP330") field(INP, "@ai0:0:DATA") field(PREC, "3") field(PRIO, "HIGH") field(TSE, "-1") field(EGUF, "5") field(EGUL, "-5") field(HOPR, "5") field(LOPR, "-5") field(ADEL, "0") field(MDEL, "0") field(HIHI, "5") field(HIGH, "5") field(LOW, "-5") field(LOLO, "-5") field(EGU, "V") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "PMTR:LT10:20:EFPWR") } record(ai, "PMTR:LT10:100:PWR") { field(DESC, "Power meter laser steering") field(SCAN, "I/O Intr") field(DTYP, "IP330") field(INP, "@ai0:1:DATA") field(PREC, "3") field(PRIO, "HIGH") field(TSE, "-1") field(EGUF, "5") field(EGUL, "-5") field(HOPR, "5") field(LOPR, "-5") field(ADEL, "0") field(MDEL, "0") field(HIHI, "5") field(HIGH, "5") field(LOW, "-5") field(LOLO, "-5") field(EGU, "V") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "PMTR:LT10:100:EFPWR") } record(ai, "PMTR:LT10:230:PWR") { field(DESC, "Power meter laser steering") field(SCAN, "I/O Intr") field(DTYP, "IP330") field(INP, "@ai0:2:DATA") field(PREC, "3") field(PRIO, "HIGH") field(TSE, "-1") field(EGUF, "5") field(EGUL, "-5") field(HOPR, "5") field(LOPR, "-5") field(ADEL, "0") field(MDEL, "0") field(HIHI, "5") field(HIGH, "5") field(LOW, "-5") field(LOLO, "-5") field(EGU, "V") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "PMTR:LT10:230:EFPWR") } record(ai, "PMTR:LT10:270:PWR") { field(DESC, "Power meter laser steering") field(SCAN, "I/O Intr") field(DTYP, "IP330") field(INP, "@ai0:3:DATA") field(PREC, "3") field(PRIO, "HIGH") field(TSE, "-1") field(EGUF, "5") field(EGUL, "-5") field(HOPR, "5") field(LOPR, "-5") field(ADEL, "0") field(MDEL, "0") field(HIHI, "5") field(HIGH, "5") field(LOW, "-5") field(LOLO, "-5") field(EGU, "V") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "PMTR:LT10:270:EFPWR") } record(ai, "PMTR:LT10:380:PWR") { field(DESC, "Power meter laser steering") field(SCAN, "I/O Intr") field(DTYP, "IP330") field(INP, "@ai0:4:DATA") field(PREC, "3") field(PRIO, "HIGH") field(TSE, "-1") field(EGUF, "5") field(EGUL, "-5") field(HOPR, "5") field(LOPR, "-5") field(ADEL, "0") field(MDEL, "0") field(HIHI, "5") field(HIGH, "5") field(LOW, "-5") field(LOLO, "-5") field(EGU, "V") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "PMTR:LT10:380:EFPWR") } record(ai, "LASR:LT10:930:PWR") { field(DESC, "Power meter laser steering") field(SCAN, "I/O Intr") field(DTYP, "IP330") field(INP, "@ai0:5:DATA") field(PREC, "3") field(PRIO, "HIGH") field(TSE, "-1") field(EGUF, "5") field(EGUL, "-5") field(HOPR, "5") field(LOPR, "-5") field(ADEL, "0") field(MDEL, "0") field(HIHI, "5") field(HIGH, "5") field(LOW, "-5") field(LOLO, "-5") field(EGU, "V") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "LASR:LT10:930:EFPWR") } record(bi, "SHTR:LT10:250:SARM_INSW") { field(DESC, "SARM In Switch") field(DTYP, "IP440") field(ZNAM, "HIGH") field(ONAM, "LOW") field(INP, "@bi0 P0 B5") field(SCAN, "1 second") info(autosaveFields, "$(AUTOSAVEFIELDS,undefined)") } record(bi, "SHTR:LT10:250:SARM_OUTSW") { field(DESC, "SARM Out Switch") field(DTYP, "IP440") field(ZNAM, "HIGH") field(ONAM, "LOW") field(INP, "@bi0 P0 B4") field(SCAN, "1 second") info(autosaveFields, "$(AUTOSAVEFIELDS,undefined)") } record(bo, "SHTR:LT10:250:SARM_SHUTTER_ENBL") { field(DESC, "SARM Shutter") field(DTYP, "ACROMAG-IP470") field(ZNAM, "HIGH") field(ONAM, "LOW") field(OUT, "@bio0 P0 B5") field(SCAN, "1 second") } record(mbbi, "SHTR:LT10:250:SARM_STS") { field(DESC,"Coherent 1 Shutter Status") field(INP, "SHTR:LT10:250:SARM_CALC") field(ZRVL,"0") field(ZRST,"MOVING") field(ZRSV,"MAJOR") field(ONVL,"1") field(ONST,"OUT") field(ONSV,"NO_ALARM") field(TWVL,"2") field(TWST,"IN") field(TWSV,"NO_ALARM") field(THVL,"3") field(THST,"INCONSISTENT") field(THSV,"MAJOR") } record(calc, SHTR:LT10:250:SARM_CALC) { field(SCAN, "1 second") field(INPA,"SHTR:LT10:250:SARM_INSW") field(INPB,"SHTR:LT10:250:SARM_OUTSW") field(CALC,"A*2+B") field(FLNK,"SHTR:LT10:250:SARM_STS") info(autosaveFields, "HHSV HSV LSV LLSV HIHI HIGH LOW LOLO") } record(bi, "SHTR:LT10:250:PARM_INSW") { field(DESC, "PARM In Switch") field(DTYP, "IP440") field(ZNAM, "HIGH") field(ONAM, "LOW") field(INP, "@bi0 P0 B7") field(SCAN, "1 second") info(autosaveFields, "$(AUTOSAVEFIELDS,undefined)") } record(bi, "SHTR:LT10:250:PARM_OUTSW") { field(DESC, "PARM Out Switch") field(DTYP, "IP440") field(ZNAM, "HIGH") field(ONAM, "LOW") field(INP, "@bi0 P0 B6") field(SCAN, "1 second") info(autosaveFields, "$(AUTOSAVEFIELDS,undefined)") } record(bo, "SHTR:LT10:250:PARM_SHUTTER_ENBL") { field(DESC, "PARM Shutter") field(DTYP, "ACROMAG-IP470") field(ZNAM, "HIGH") field(ONAM, "LOW") field(OUT, "@bio0 P0 B4") field(SCAN, "1 second") } record(mbbi, "SHTR:LT10:250:PARM_STS") { field(DESC,"Coherent 1 Shutter Status") field(INP, "SHTR:LT10:250:PARM_CALC") field(ZRVL,"0") field(ZRST,"MOVING") field(ZRSV,"MAJOR") field(ONVL,"1") field(ONST,"OUT") field(ONSV,"NO_ALARM") field(TWVL,"2") field(TWST,"IN") field(TWSV,"NO_ALARM") field(THVL,"3") field(THST,"INCONSISTENT") field(THSV,"MAJOR") } record(calc, SHTR:LT10:250:PARM_CALC) { field(SCAN, "1 second") field(INPA,"SHTR:LT10:250:PARM_INSW") field(INPB,"SHTR:LT10:250:PARM_OUTSW") field(CALC,"A*2+B") field(FLNK,"SHTR:LT10:250:PARM_STS") info(autosaveFields, "HHSV HSV LSV LLSV HIHI HIGH LOW LOLO") }