#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:IN20:231:EDES") {
  field(DESC, "Gun energy (BXG unit#)")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:IN20:231:EDES",2300,2242,0,1,"REFS:IN20:231:EDES")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:IN20:751:EDES") {
  field(DESC, "DL1 energy (BX02 unit#)")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:IN20:751:EDES",2300,2242,0,1,"REFS:IN20:751:EDES")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:LI21:231:EDES") {
  field(DESC, "BC1 energy (BX12 unit#)")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:LI21:231:EDES",2300,2242,0,1,"REFS:LI21:231:EDES")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:LI24:790:EDES") {
  field(DESC, "BC2 energy (BX21 unit#)")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:LI24:790:EDES",2300,2242,0,1,"REFS:LI24:790:EDES")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:LI30:995:EDES") {
  field(DESC, "L3 energy")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:LI30:995:EDES",2300,2242,0,1,"REFS:LI30:995:EDES")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:DMPS:400:EDES") {
  field(DESC, "main CU_SXR dmp energy (BYD1 unit#)")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:DMPS:400:EDES",2300,2242,0,1,"REFS:DMPS:400:EDES")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:DMPH:400:EDES") {
  field(DESC, "main CU_HXR dmp energy (BYD1 unit#)")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:DMPH:400:EDES",2300,2242,0,1,"REFS:DMPH:400:EDES")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:LI21:231:EDES_PSVPRED") {
  field(DESC, "Next BC1 energy (BX12 unit#)")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:LI21:231:EDES_PSVPRED",2300,2242,0,1,"REFS:LI21:231:EDES_PSVPRED")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:LI24:790:EDES_PSVPRED") {
  field(DESC, "Next BC2 energy (BX21 unit#)")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:LI24:790:EDES_PSVPRED",2300,2242,0,1,"REFS:LI24:790:EDES_PSVPRED")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:DMPH:400:EDES_PSVPRED") {
  field(DESC, "Next main dmp energy (BYD1 unit#)")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:DMPH:400:EDES_PSVPRED",2300,2242,0,1,"REFS:DMPH:400:EDES_PSVPRED")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:LI30:901:EDES") {
  field(DESC, "")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:LI30:901:EDES",2300,2242,0,1,"REFS:LI30:901:EDES")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:LI30:902:EDES") {
  field(DESC, "")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:LI30:902:EDES",2300,2242,0,1,"REFS:LI30:902:EDES")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:GUNB:950:EDES") {
  field(DESC, "")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:GUNB:950:EDES",2300,2242,0,1,"REFS:GUNB:950:EDES")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:COL0:950:EDES") {
  field(DESC, "")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:COL0:950:EDES",2300,2242,0,1,"REFS:COL0:950:EDES")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:BC1B:400:EDES") {
  field(DESC, "")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:BC1B:400:EDES",2300,2242,0,1,"REFS:BC1B:400:EDES")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:BC2B:500:EDES") {
  field(DESC, "")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:BC2B:500:EDES",2300,2242,0,1,"REFS:BC2B:500:EDES")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:CLTH:400:EDES") {
  field(DESC, "")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:CLTH:400:EDES",2300,2242,0,1,"REFS:CLTH:400:EDES")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:BYP:400:EDES") {
  field(DESC, "")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:BYP:400:EDES",2300,2242,0,1,"REFS:BYP:400:EDES")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../dbd/LEMserverSoft.dbd")
#! DBDEND



record(ao, "REFS:BSYD:400:EDES") {
  field(DESC, "")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(PREC, "2")
  field(LINR, "NO CONVERSION")
  field(EGU, "GeV")
  info(autosaveFields_pass0, "VAL DRVH DRVL HOPR LOPR HIGH HIHI LOW LOLO HHSV HSV LLSV LSV")
}

#! Further lines contain data used by VisualDCT
#! View(3245,3331,1.5)
#! Record("REFS:BSYD:400:EDES",2300,2242,0,1,"REFS:BSYD:400:EDES")
