# Common st.cmd
#

# Change directory to TOP of application
cd(${TOP})

## Override any environment variables
< iocBoot/common/envVars

## Register all support components
dbLoadDatabase("dbd/klystronSupport.dbd")
klystronSupport_registerRecordDeviceDriver(pdbbase)

## Load specific databases
< iocBoot/${IOC}/loadDBs

## Load common databases
dbLoadRecords("db/iocRelease.db","IOC=SIOC:${LINAC_SECTOR}:KY00") 
dbLoadRecords("db/NOW.db","MICRO=${LINAC_SECTOR}")

# Load the seq stats database
dbLoadRecords("db/devSeqCar.db","SIOC=SIOC:${LINAC_SECTOR}:KY00")

## Setup autosave/restore
set_requestfile_path("${IOC_DATA}/${IOC}/autosave-req")
set_savefile_path("${IOC_DATA}/${IOC}/autosave")

save_restoreSet_status_prefix("SIOC:${LINAC_SECTOR}:KY00:")
dbLoadRecords("db/save_restoreStatus.db", "P=SIOC:${LINAC_SECTOR}:KY00:")

## iocAdmin
epicsEnvSet("STARTUP","/usr/local/lcls/epics/iocCommon/${IOC}")
epicsEnvSet("ST_CMD","startup.cmd")
dbLoadRecords("db/iocAdminSoft.db","IOC=SIOC:${LINAC_SECTOR}:KY00")

## Restore datasets
set_pass0_restoreFile("info_settings.sav")
set_pass1_restoreFile("info_settings.sav")

## Note that autosave/restore spews a lot of messages and message
## throttling throttles all of the seq messages below.

iocInit()

## Start logging messages before starting sequences.
iocLogInit()

# These should be in autosave, but are not
dbpf(SIOC:${LINAC_SECTOR}:KY00:nDisconnect.HIGH, 30)
dbpf(SIOC:${LINAC_SECTOR}:KY00:nDisconnect.HIHI, 30)

## Start any sequence programs
< iocBoot/${IOC}/startSeq

## Inform Archive Appliance of PVs needing Archive.
< iocBoot/common/setupArchive.cmd

## Start saving datasets
cd("${IOC_DATA}/${IOC}/autosave-req")
epicsThreadSleep(1)
makeAutosaveFiles()
epicsThreadSleep(1)
create_monitor_set("info_settings.req",60,"")
epicsThreadSleep(1)
create_monitor_set("info_positions.req",60,"")
epicsThreadSleep(1)

# change to boot directory
cd("${TOP}/iocBoot/${IOC}")

#[eof common/st.cmd]