ReplyTimeout = 10000;
ReadTimeout = 2000;
ExtraInput = Ignore;

setLogin {
	# send username and password on initial connect.  reconnection is handled by readtimeout under getOutletState below.
	InTerminator = ":";
	in "\xff\xfb\x01\r\nUser Name ";
	out "ups-mgr\rups4mgr\r";
}

getInfo {
        ExtraInput = Ignore;
        in "%(\$1:NETFWVERSION.VAL).1/AOS.*?v([0-9.]*?)\r\n+/"
           "%(\$1:FWVERSION.VAL).1/APP.*?v([0-9.]*?)\r\n+/"
           "%(\$1:DUMMY.VAL).1/(.*?)\r\n+/"
           "%(\$1:NODENAME.VAL).1/Name.*:.*?([A-Za-z0-9]+-[A-Za-z0-9]+-[A-Za-z0-9]+).*?\r\n+/";
}

setCleanInput {
#	out "dummy\r";
	out "  ";
	in "%(\$1:CMDERRMSG)s";
}

setReconnect {
	out "\x1b";
	in "%(\$1:CMDERRMSG)s";
	out "ups-mgr\rups4mgr\r\n";
        wait 800;
}

getStatusAll {
	out "detstatus -all\r\n";
        InTerminator = "\r\n";
        in "detstatus -all";
        in "E%(\$1:CMDERRCODE)i: %(\$1:CMDERRMSG)40c";
        in "Status of UPS: %(\$1:UPSSTATUS.VAL)20c";
        in "Last Transfer: %(\$1:LASTXFER)90c";
        in "Input Status: %(\$1:INPSTATUS)40c";
        in "Replace Battery Date: %(\$1:BATTDATE)40c";
        in "Runtime Remaining: %(\$1:RTLEFT.VAL)40c";
        in "Battery State Of Charge: %(\$1:BATTPCTSTR.VAL)s \%";
        in  "Output Voltage: %(\$1:OUTVSTR.VAL)s VAC";
        in  "Output Frequency: %(\$1:OUTFREQSTR.VAL)s Hz";
        in  "Output Watts Percent: %(\$1:OUTWATTSPCTSTR.VAL)s \%";
        in  "Output VA Percent: %(\$1:OUTVAPCTSTR.VAL)s \%";
        in  "Output Current: %(\$1:OUTCURRSTR.VAL)s A";
        in  "Output Efficiency: %(\$1:OUTEFFSTR.VAL)40c";
        in  "Output Energy: %(\$1:OUTESTR.VAL)s kWh";
        in  "Input Voltage: %(\$1:INPVSTR.VAL)s VAC";
        in  "Input Frequency: %(\$1:INPFREQSTR.VAL)s Hz";
        in  "Battery Voltage: %(\$1:BATTVSTR.VAL)s VDC";
        in  "Battery Temperature: %(\$1:BATTTEMPCSTR.VAL)s C, %(\$1:BATTTEMPFSTR.VAL)s F";
        in  "Self-Test Result: %(\$1:STESTRES.VAL)40c";
        in  "Self-Test Date: %(\$1:STESTDATE.VAL)40c";
        in  "Calibration Result: %(\$1:CALRES.VAL)40c";
        in  "Calibration Date: %(\$1:CALDATE.VAL)40c";
        wait 800;
        @readtimeout {
		setReconnect;
        }
}

getGroupStatus1 {
	out "ups -os 1\r\n";
        InTerminator = "\r\n";
	in "";
        in "E%(\$1:CMDERRCODE)i: %(\$1:CMDERRMSG)40c";
        in "main outlet group State: %(\$1:GROUPSTATUS1.VAL)20c";
        wait 800;
        @readtimeout {
		setReconnect;
	}
}

getGroupStatus2 {
	out "ups -os 2\r\n";
        InTerminator = "\r\n";
	in "";
        in "E%(\$1:CMDERRCODE)i: %(\$1:CMDERRMSG)40c";
        in "Outlet1 State: %(\$1:GROUPSTATUS2.VAL)20c";
        wait 800;
        @readtimeout {
		setReconnect;
	}
}

setDisconnect {
        out "exit\r\n";
}

setGroupOff {
        out "ups -o \$1 Off\r\n";
        wait 1000;
}

setGroupOn {
        out "ups -o \$1 On\r\n";
        wait 1000;
}

setGroupReboot {
        out "ups -o \$1 Reboot\r\n";
        wait 2000;
}


# from the doc
debug {
    ExtraInput = Ignore;
    out "%s"; in "%39c"
}