record(stringin, "$(dev):LOGIN") { field(PINI, "YES") field(DTYP, "stream") field(INP, "@ups_apc.proto.db setLogin($(dev)) $(link)") field(FLNK, "$(dev):GETINFO") } record(stringin, "$(dev):GETINFO") { field(DTYP, "stream") field(INP, "@ups_apc.proto.db getInfo($(dev)) $(link)") } record(stringin, "$(dev):FWVERSION") { field(SCAN, "10 second") } record(stringin, "$(dev):NETFWVERSION") { field(DESC, "Network adapter fw vers") } record(stringin, "$(dev):NODENAME") { field(DESC, "UPS node name") } record(stringin, "$(dev):DUMMY") { field(DESC, "DUMMY") } record(ai, "$(dev):TYPE") { field(DESC, "UPS") field(PINI, "YES") field(VAL, "19") } record(stringin, "$(dev):CMDERRMSG") { field(DESC, "Command error message") } record(ai, "$(dev):CMDERRCODE") { field(DESC, "Command error code") } record(ai, "$(dev):EXTRACHARS") { field(DESC, "to get extra chars at the end") } record(stringin, "$(dev):LOC") { field(PINI, "YES") field(VAL, "B34") info(autosaveFields,"VAL") } record(stringin, "$(dev):1NAME") { field(DESC, "Group device name") field(PINI, "YES") } record(stringin, "$(dev):2NAME") { field(DESC, "Group device name") field(PINI, "YES") } ### control record(bo, "$(dev):POWEROFF1") { field(DTYP, "stream") field(OUT, "@ups_apc.proto.db setGroupOff(1) $(link)") } record(bo, "$(dev):POWERON1") { field(DTYP, "stream") field(OUT, "@ups_apc.proto.db setGroupOn(1) $(link)") } record(bo, "$(dev):POWEROFF2") { field(DTYP, "stream") field(OUT, "@ups_apc.proto.db setGroupOff(2) $(link)") } record(bo, "$(dev):POWERON2") { field(DTYP, "stream") field(OUT, "@ups_apc.proto.db setGroupOn(2) $(link)") } record(bo, "$(dev):REBOOT1") { field(DTYP, "stream") field(OUT, "@ups_apc.proto.db setGroupReboot(1) $(link)") } record(bo, "$(dev):REBOOT2") { field(DTYP, "stream") field(OUT, "@ups_apc.proto.db setGroupReboot(2) $(link)") } ############ get PVs for ALL # this one works, but using waits in the protocols is better! # this way is NOT USED anymore, but keeping around for # sentimental reasons! # NOT USED record(seq, "$(dev):GETALL") { field(SELM, "All") # field(SCAN, "5 second") field(DOL1, "1") field(LNK1, "$(dev):UPSSTATUS.PROC") field(DLY2, ".5") field(DOL2, "1") field(LNK2, "$(dev):GROUPSTATUS1.PROC") field(DLY3, ".5") field(DOL3, "1") field(LNK3, "$(dev):GROUPSTATUS2.PROC") } # could process all the scalcouts with a fanout # USING THIS ONE TO DRIVE THE INPUTS (SCAN) record(stringin, "$(dev):UPSSTATUS") { field(DESC, "UPS Status") field(DTYP, "stream") field(SCAN, "5 second") field(INP, "@ups_apc.proto.db getStatusAll($(dev)) $(link)") field(FLNK, "$(dev):INPFANO") } record(fanout, "$(dev):INPFANO") { # Probably redundant, see if BATTDATE still changes field(LNK1, "$(dev):LASTXFER") field(LNK2, "$(dev):UPSSTATUSSV") field(FLNK, "$(dev):GROUPSTATUS1") } # check for No Batteries condition # we may need to add more alarm states as we go along record(scalcout, "$(dev):UPSSTATUSSV") { field(CALC, "AA==BB?1:AA==CC?1:AA==DD?1:AA==EE?1:0") field(INAA, "$(dev):UPSSTATUS MS") field(BB, "Online, No Batteries") field(CC, "Off, No Batteries") field(DD, "Offline, No Batteries") field(EE, "Off") field(FLNK, "$(dev):UPSSTATUSAL") } record(mbbi, "$(dev):UPSSTATUSAL") { field(INP, "$(dev):UPSSTATUSSV MS") field(FLNK, "") field(ZRST, "Ok") field(ONST, "ERROR") field(ZRSV, "NO_ALARM") field(ONSV, "MAJOR") } record(stringin, "$(dev):GROUPSTATUS1") { field(DESC, "UPS Status") field(DTYP, "stream") field(INP, "@ups_apc.proto.db getGroupStatus1($(dev)) $(link)") field(FLNK, "$(dev):GROUPSTATUS1SV") } record(scalcout, "$(dev):GROUPSTATUS1SV") { field(CALC, "AA==CC?0:AA==DD?1:2") field(INAA, "$(dev):GROUPSTATUS1") field(INBB, "$(dev):UPSSTATUS MS") field(CC, "On") field(DD, "Off") field(FLNK, "$(dev):GROUPSTATUS1AL") } record(mbbi, "$(dev):GROUPSTATUS1AL") { field(INP, "$(dev):GROUPSTATUS1SV MS") field(FLNK, "") field(ZRST, "On") field(ONST, "Off") field(ZRSV, "NO_ALARM") field(ONSV, "MAJOR") field(TWSV, "MINOR") field(FLNK, "$(dev):GROUPSTATUS2") } record(stringin, "$(dev):GROUPSTATUS2") { field(DESC, "UPS Status") field(DTYP, "stream") field(INP, "@ups_apc.proto.db getGroupStatus2($(dev)) $(link)") field(FLNK, "$(dev):GROUPSTATUS2SV") } record(scalcout, "$(dev):GROUPSTATUS2SV") { field(CALC, "AA==CC?0:AA==DD?1:2") field(INAA, "$(dev):GROUPSTATUS2") field(INBB, "$(dev):UPSSTATUS MS") field(CC, "On") field(DD, "Off") field(FLNK, "$(dev):GROUPSTATUS2AL") } record(mbbi, "$(dev):GROUPSTATUS2AL") { field(INP, "$(dev):GROUPSTATUS2SV MS") field(FLNK, "") field(ZRST, "On") field(ONST, "Off") field(ZRSV, "NO_ALARM") field(ONSV, "MAJOR") field(TWSV, "MINOR") } record(stringin, "$(dev):LASTXFER") { field(DESC, "Last Transfer") } record(stringin, "$(dev):INPSTATUS") { field(DESC, "Input Status") } record(stringin, "$(dev):BATTDATE") { field(DESC, "Replace Battery Date") } record(stringin, "$(dev):RTLEFT") { field(DESC, "runtime remaining") field(FLNK, "$(dev):BATTPCT") } record(stringin, "$(dev):BATTPCTSTR") { field(DESC, "battery percent") } # TRY MS ON BB TO PROPAGATE SEVR FROM UPSSTATUS record(scalcout, "$(dev):BATTPCT") { field(DESC, "percent battery left") field(CALC, "DBL(AA)") field(INAA, "$(dev):BATTPCTSTR") field(INBB, "$(dev):UPSSTATUS MS") field(EGU, "%") field(LOW, "30") field(LOLO, "20") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "$(dev):OUTV") } record(stringin, "$(dev):OUTVSTR") { field(DESC, "output voltage") } record(scalcout, "$(dev):OUTV") { field(DESC, "output voltage") field(CALC, "DBL(AA)") field(INAA, "$(dev):OUTVSTR") field(EGU, "VAC") field(FLNK, "$(dev):OUTFREQ") } record(stringin, "$(dev):OUTFREQSTR") { field(DESC, "output frequency") } record(scalcout, "$(dev):OUTFREQ") { field(DESC, "output frequency") field(CALC, "DBL(AA)") field(INAA, "$(dev):OUTFREQSTR") field(EGU, "Hz") field(FLNK, "$(dev):OUTWATTSPCT") } record(ai, "$(dev):OUTWATTSPCTSTR") { field(DESC, "Output Watts %") } record(scalcout, "$(dev):OUTWATTSPCT") { field(DESC, "output watts %") field(CALC, "DBL(AA)") field(INAA, "$(dev):OUTWATTSPCTSTR") field(EGU, "%") field(FLNK, "$(dev):OUTVAPCT") } record(stringin, "$(dev):OUTVAPCTSTR") { field(DESC, "output VA percent") } record(scalcout, "$(dev):OUTVAPCT") { field(DESC, "output VA percent") field(CALC, "DBL(AA)") field(INAA, "$(dev):OUTVAPCTSTR") field(EGU, "%") field(FLNK, "$(dev):OUTCURR") } record(stringin, "$(dev):OUTCURRSTR") { field(DESC, "output current") } record(scalcout, "$(dev):OUTCURR") { field(DESC, "output current") field(CALC, "DBL(AA)") field(INAA, "$(dev):OUTCURRSTR") field(EGU, "A") field(FLNK, "$(dev):OUTE") } record(stringin, "$(dev):OUTESTR") { field(DESC, "output Energy") } record(scalcout, "$(dev):OUTE") { field(DESC, "output energy") field(CALC, "DBL(AA)") field(INAA, "$(dev):OUTESTR") field(EGU, "kWh") field(FLNK, "$(dev):INPV") } record(stringin, "$(dev):INPVSTR") { field(DESC, "input voltage") } record(scalcout, "$(dev):INPV") { field(DESC, "input voltage") field(CALC, "DBL(AA)") field(INAA, "$(dev):INPVSTR") field(INBB, "$(dev):UPSSTATUS MS") field(EGU, "VAC") field(LOW, "100") field(LSV, "MINOR") field(FLNK, "$(dev):INPFREQ") } record(stringin, "$(dev):INPFREQSTR") { field(DESC, "input frequency") } record(scalcout, "$(dev):INPFREQ") { field(DESC, "input frequency") field(CALC, "DBL(AA)") field(INAA, "$(dev):INPFREQSTR") field(INBB, "$(dev):UPSSTATUS MS") field(EGU, "Hz") field(LOW, "50") field(LSV, "MINOR") field(FLNK, "$(dev):BATTV") } record(stringin, "$(dev):BATTVSTR") { field(DESC, "battery voltage") } record(scalcout, "$(dev):BATTV") { field(DESC, "battery voltage") field(CALC, "DBL(AA)") field(INAA, "$(dev):BATTVSTR") field(INBB, "$(dev):UPSSTATUS MS") field(EGU, "VDC") field(LOW, "40") field(LSV, "MINOR") field(FLNK, "$(dev):BATTTEMPC") } record(stringin, "$(dev):BATTTEMPCSTR") { field(DESC, "battery temperature (C)") } record(scalcout, "$(dev):BATTTEMPC") { field(DESC, "battery temperature (C)") field(CALC, "DBL(AA)") field(INAA, "$(dev):BATTTEMPCSTR") field(EGU, "deg C") field(FLNK, "$(dev):BATTTEMPF") } record(stringin, "$(dev):BATTTEMPFSTR") { field(DESC, "battery temperature (F)") } record(scalcout, "$(dev):BATTTEMPF") { field(DESC, "battery temperature (F)") field(CALC, "DBL(AA)") field(INAA, "$(dev):BATTTEMPFSTR") field(EGU, "deg F") field(FLNK, "$(dev):OUTEFF") } record(stringin, "$(dev):OUTEFFSTR") { field(DESC, "output efficiency") } record(scalcout, "$(dev):OUTEFF") { field(DESC, "output efficiency") field(CALC, "DBL(AA)") field(INAA, "$(dev):OUTEFFSTR") field(EGU, "%") } #record(ai, "$(dev):OUTEFF") { # field(DESC, "output efficiency") # field(EGU, "%") # field(PREC, 2) #} record(stringin, "$(dev):INPUTERR") { field(DESC, "mismatch") } record(stringin, "$(dev):STESTRES") { field(DESC, "self-test result") } record(stringin, "$(dev):STESTDATE") { field(DESC, "self-test date") } record(stringin, "$(dev):CALRES") { field(DESC, "calibration result") } record(stringin, "$(dev):CALDATE") { field(DESC, "calibration date") } ########## STARTING POINT: SONYA'S ACSW DB record(bo, "$(dev):DISCONN") { field(DESC, "Disconn to allow access") field(DISA, "1") field(DISS, "NO_ALARM") field(DTYP, "stream") field(OUT, "@ups_apc.proto.db setDisconnect $(link)") } # added this record(bo, "$(dev):CLEAN") { field(DESC, "clean up extraneous input") field(DTYP, "stream") field(OUT, "@ups_apc.proto.db setCleanInput($(dev)) $(link)") } record(bo, "$(dev):RECONN") { field(DESC, "Reconnect") field(DTYP, "stream") field(OUT, "@ups_apc.proto.db setReconnect($(dev)) $(link)") } record(calcout, "$(dev):CONNCALC") { field(CALC, "A=B && C#D") field(SCAN, "2 second") field(INPA, "$(dev):DISCONN.DISA") field(INPB, "$(dev):DISCONN.DISV") field(INPC, "$(dev):UPSSTATUS.DISA") field(INPD, "$(dev):UPSSTATUS.DISV") field(OOPT, "On Change") field(OUT, "$(dev):CONNSTA PP") } record(bi, "$(dev):CONNSTA") { field(ZNAM, "Not connected") field(ONAM, "Connected") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } # Disconnect from UPS to allow # other clients access to UPS # UPSSTATUS protocol will reconnect if needed record(seq, "$(dev):ACCSTART") { field(SELM, "All") field(DOL1, "1") field(LNK1, "$(dev):UPSSTATUS.DISA") field(DOL2, "0") field(LNK2, "$(dev):DISCONN.DISA PP") } # Reconnect to UPS # First reconnect and wait a little to allow reconn to complete # Then enable parameter readback again, and disable disconnect # This way results in less garbage as the connection inputs sort # themselves out (altho there can be some, resolved eventually) record(seq, "$(dev):ACCSTOP") { field(SELM, "All") field(DOL1, "1") field(LNK1, "$(dev):RECONN.PROC") field(DLY2, "1") field(DOL2, "0") field(LNK2, "$(dev):UPSSTATUS.DISA") field(DOL3, "1") field(LNK3, "$(dev):DISCONN.DISA") }