# CAMAC switch status PVs # Status read in over CA from CAMAC IOCs # These PVs mirror that status or if the # IOC is offline, report "Unknown" record(mbbi, "132-CCB4C1:SWITCHSTS") { field(DESC, "CAMAC controller") field(DTYP, "Raw Soft Channel") field(INP, "132-CCB4C1:SWITCHSTSCALC MS NPP") field(ZRVL, "0") field(ONVL, "1") field(TWVL, "2") field(ZRST, "Micro") field(ONST, "IOC") field(TWST, "Unknown") field(TWSV, "INVALID") } record(calc, "132-CCB4C1:SWITCHSTSCALC") { field(ASG, "Internal") field(CALC, "B=3?2:A=0?1:0") field(INPA, "132-CCB4C1:SWITCHSTSINP MS NPP") field(INPB, "132-CCB4C1:SWITCHSTSINP.SEVR MS NPP") field(FLNK, "132-CCB4C1:SWITCHSTS") } record(bi, "132-CCB4C1:SWITCHSTSINP") { field(SCAN, "1 second") field(INP, "CAMI:B132:1:SwitchSts MS NPP") field(FLNK, "132-CCB4C1:SWITCHSTSCALC") } record(mbbi, "132-CCB4C1:LOCALREMOTE") { field(DESC, "CAMAC loc/rem cntrl") field(DTYP, "Raw Soft Channel") field(INP, "132-CCB4C1:LOCALREMOTECALC MS NPP") field(ZRVL, "0") field(ONVL, "1") field(TWVL, "2") field(ZRST, "Local") field(ONST, "Remote") field(TWST, "Unknown") field(TWSV, "INVALID") } record(calc, "132-CCB4C1:LOCALREMOTECALC") { field(ASG, "Internal") field(CALC, "B=3?2:A") field(INPA, "132-CCB4C1:LOCALREMOTEINP MS NPP") field(INPB, "132-CCB4C1:LOCALREMOTEINP.SEVR MS NPP") field(FLNK, "132-CCB4C1:LOCALREMOTE") } record(bi, "132-CCB4C1:LOCALREMOTEINP") { field(SCAN, "1 second") field(ASG, "Internal") field(INP, "CAMI:B132:1:LocalRemote MS NPP") field(FLNK, "132-CCB4C1:LOCALREMOTECALC") } record(bo, "132-CCB4C1:SWITCHSET") { field(DESC, "Set PSCD/MBCD mode") field(OUT, "CAMI:B132:1:SwitchSet") field(ZNAM, "IOC") field(ONAM, "MICRO") } record(stringout, "132-CCB4C1:QC_MSG") { field(DESC, "Switchover script msg") field(VAL, "") field(PINI, "YES") field(FLNK, "132-CCB4C1:QC_MSGTS") } record(stringin, "132-CCB4C1:QC_MSGTS") { field(DESC, "Switchover script timestamp") field(DTYP, "Soft Timestamp") field(VAL, "Unknown") field(INP, "@%m/%d/%Y %H:%M:%S") } record(longout, "B132-IOCCAMAC:NCRAT") { field(DESC, "Num CAMAC Crates") field(EGU, "Num") field(VAL, "1") field(PINI, "YES") } #! Generated by VisualDCT v2.6 #! DBDSTART #! DBDEND record(stringin, "132-CCB4C1:LOC") { field(DESC, "CAMAC crate location") field(PINI, "YES") field(VAL, "B132-102-4-27") } record(longin, "132-CCB4C1:BRANCH") { field(DESC, "CAMAC crate branch") field(PINI, "YES") field(VAL, "0") field(EGU, "Branch No.") } record(mbbo, "MODU:B132:101:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "1") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:101:NCHAN_CALC") } record(calc,"MODU:B132:101:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:101:MODEL") field(FLNK, "MODU:B132:101:NCHAN") } record(longout, "MODU:B132:101:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:101:NCHAN_CALC") field(FLNK, "MODU:B132:101:NSLOT_CALC") } record(calc,"MODU:B132:101:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:101:MODEL") field(FLNK, "MODU:B132:101:NSLOT") } record(longout, "MODU:B132:101:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:101:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:101:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:101:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "01") field(PINI, "YES") } record(mbbo, "MODU:B132:102:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "0") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:102:NCHAN_CALC") } record(calc,"MODU:B132:102:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:102:MODEL") field(FLNK, "MODU:B132:102:NCHAN") } record(longout, "MODU:B132:102:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:102:NCHAN_CALC") field(FLNK, "MODU:B132:102:NSLOT_CALC") } record(calc,"MODU:B132:102:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:102:MODEL") field(FLNK, "MODU:B132:102:NSLOT") } record(longout, "MODU:B132:102:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:102:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:102:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:102:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "02") field(PINI, "YES") } record(mbbo, "MODU:B132:103:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "1") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:103:NCHAN_CALC") } record(calc,"MODU:B132:103:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:103:MODEL") field(FLNK, "MODU:B132:103:NCHAN") } record(longout, "MODU:B132:103:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:103:NCHAN_CALC") field(FLNK, "MODU:B132:103:NSLOT_CALC") } record(calc,"MODU:B132:103:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:103:MODEL") field(FLNK, "MODU:B132:103:NSLOT") } record(longout, "MODU:B132:103:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:103:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:103:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:103:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "03") field(PINI, "YES") } record(mbbo, "MODU:B132:104:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "1") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:104:NCHAN_CALC") } record(calc,"MODU:B132:104:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:104:MODEL") field(FLNK, "MODU:B132:104:NCHAN") } record(longout, "MODU:B132:104:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:104:NCHAN_CALC") field(FLNK, "MODU:B132:104:NSLOT_CALC") } record(calc,"MODU:B132:104:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:104:MODEL") field(FLNK, "MODU:B132:104:NSLOT") } record(longout, "MODU:B132:104:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:104:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:104:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:104:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "04") field(PINI, "YES") } record(mbbo, "MODU:B132:105:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "1") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:105:NCHAN_CALC") } record(calc,"MODU:B132:105:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:105:MODEL") field(FLNK, "MODU:B132:105:NCHAN") } record(longout, "MODU:B132:105:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:105:NCHAN_CALC") field(FLNK, "MODU:B132:105:NSLOT_CALC") } record(calc,"MODU:B132:105:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:105:MODEL") field(FLNK, "MODU:B132:105:NSLOT") } record(longout, "MODU:B132:105:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:105:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:105:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:105:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "05") field(PINI, "YES") } record(mbbo, "MODU:B132:106:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "0") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:106:NCHAN_CALC") } record(calc,"MODU:B132:106:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:106:MODEL") field(FLNK, "MODU:B132:106:NCHAN") } record(longout, "MODU:B132:106:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:106:NCHAN_CALC") field(FLNK, "MODU:B132:106:NSLOT_CALC") } record(calc,"MODU:B132:106:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:106:MODEL") field(FLNK, "MODU:B132:106:NSLOT") } record(longout, "MODU:B132:106:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:106:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:106:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:106:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "06") field(PINI, "YES") } record(mbbo, "MODU:B132:107:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "1") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:107:NCHAN_CALC") } record(calc,"MODU:B132:107:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:107:MODEL") field(FLNK, "MODU:B132:107:NCHAN") } record(longout, "MODU:B132:107:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:107:NCHAN_CALC") field(FLNK, "MODU:B132:107:NSLOT_CALC") } record(calc,"MODU:B132:107:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:107:MODEL") field(FLNK, "MODU:B132:107:NSLOT") } record(longout, "MODU:B132:107:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:107:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:107:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:107:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "07") field(PINI, "YES") } record(mbbo, "MODU:B132:108:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "0") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:108:NCHAN_CALC") } record(calc,"MODU:B132:108:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:108:MODEL") field(FLNK, "MODU:B132:108:NCHAN") } record(longout, "MODU:B132:108:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:108:NCHAN_CALC") field(FLNK, "MODU:B132:108:NSLOT_CALC") } record(calc,"MODU:B132:108:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:108:MODEL") field(FLNK, "MODU:B132:108:NSLOT") } record(longout, "MODU:B132:108:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:108:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:108:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:108:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "08") field(PINI, "YES") } record(mbbo, "MODU:B132:109:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "1") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:109:NCHAN_CALC") } record(calc,"MODU:B132:109:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:109:MODEL") field(FLNK, "MODU:B132:109:NCHAN") } record(longout, "MODU:B132:109:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:109:NCHAN_CALC") field(FLNK, "MODU:B132:109:NSLOT_CALC") } record(calc,"MODU:B132:109:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:109:MODEL") field(FLNK, "MODU:B132:109:NSLOT") } record(longout, "MODU:B132:109:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:109:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:109:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:109:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "09") field(PINI, "YES") } record(mbbo, "MODU:B132:110:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "1") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:110:NCHAN_CALC") } record(calc,"MODU:B132:110:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:110:MODEL") field(FLNK, "MODU:B132:110:NCHAN") } record(longout, "MODU:B132:110:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:110:NCHAN_CALC") field(FLNK, "MODU:B132:110:NSLOT_CALC") } record(calc,"MODU:B132:110:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:110:MODEL") field(FLNK, "MODU:B132:110:NSLOT") } record(longout, "MODU:B132:110:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:110:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:110:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:110:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "10") field(PINI, "YES") } record(mbbo, "MODU:B132:111:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "1") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:111:NCHAN_CALC") } record(calc,"MODU:B132:111:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:111:MODEL") field(FLNK, "MODU:B132:111:NCHAN") } record(longout, "MODU:B132:111:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:111:NCHAN_CALC") field(FLNK, "MODU:B132:111:NSLOT_CALC") } record(calc,"MODU:B132:111:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:111:MODEL") field(FLNK, "MODU:B132:111:NSLOT") } record(longout, "MODU:B132:111:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:111:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:111:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:111:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "11") field(PINI, "YES") } record(mbbo, "MODU:B132:112:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "0") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:112:NCHAN_CALC") } record(calc,"MODU:B132:112:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:112:MODEL") field(FLNK, "MODU:B132:112:NCHAN") } record(longout, "MODU:B132:112:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:112:NCHAN_CALC") field(FLNK, "MODU:B132:112:NSLOT_CALC") } record(calc,"MODU:B132:112:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:112:MODEL") field(FLNK, "MODU:B132:112:NSLOT") } record(longout, "MODU:B132:112:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:112:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:112:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:112:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "12") field(PINI, "YES") } record(mbbo, "MODU:B132:113:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "1") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:113:NCHAN_CALC") } record(calc,"MODU:B132:113:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:113:MODEL") field(FLNK, "MODU:B132:113:NCHAN") } record(longout, "MODU:B132:113:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:113:NCHAN_CALC") field(FLNK, "MODU:B132:113:NSLOT_CALC") } record(calc,"MODU:B132:113:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:113:MODEL") field(FLNK, "MODU:B132:113:NSLOT") } record(longout, "MODU:B132:113:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:113:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:113:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:113:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "13") field(PINI, "YES") } record(mbbo, "MODU:B132:114:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "0") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:114:NCHAN_CALC") } record(calc,"MODU:B132:114:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:114:MODEL") field(FLNK, "MODU:B132:114:NCHAN") } record(longout, "MODU:B132:114:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:114:NCHAN_CALC") field(FLNK, "MODU:B132:114:NSLOT_CALC") } record(calc,"MODU:B132:114:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:114:MODEL") field(FLNK, "MODU:B132:114:NSLOT") } record(longout, "MODU:B132:114:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:114:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:114:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:114:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "14") field(PINI, "YES") } record(mbbo, "MODU:B132:115:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "1") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:115:NCHAN_CALC") } record(calc,"MODU:B132:115:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:115:MODEL") field(FLNK, "MODU:B132:115:NCHAN") } record(longout, "MODU:B132:115:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:115:NCHAN_CALC") field(FLNK, "MODU:B132:115:NSLOT_CALC") } record(calc,"MODU:B132:115:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:115:MODEL") field(FLNK, "MODU:B132:115:NSLOT") } record(longout, "MODU:B132:115:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:115:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:115:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:115:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "15") field(PINI, "YES") } record(mbbo, "MODU:B132:116:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "0") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:116:NCHAN_CALC") } record(calc,"MODU:B132:116:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:116:MODEL") field(FLNK, "MODU:B132:116:NCHAN") } record(longout, "MODU:B132:116:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:116:NCHAN_CALC") field(FLNK, "MODU:B132:116:NSLOT_CALC") } record(calc,"MODU:B132:116:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:116:MODEL") field(FLNK, "MODU:B132:116:NSLOT") } record(longout, "MODU:B132:116:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:116:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:116:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:116:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "16") field(PINI, "YES") } record(mbbo, "MODU:B132:117:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "1") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:117:NCHAN_CALC") } record(calc,"MODU:B132:117:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:117:MODEL") field(FLNK, "MODU:B132:117:NCHAN") } record(longout, "MODU:B132:117:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:117:NCHAN_CALC") field(FLNK, "MODU:B132:117:NSLOT_CALC") } record(calc,"MODU:B132:117:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:117:MODEL") field(FLNK, "MODU:B132:117:NSLOT") } record(longout, "MODU:B132:117:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:117:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:117:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:117:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "17") field(PINI, "YES") } record(mbbo, "MODU:B132:118:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "0") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:118:NCHAN_CALC") } record(calc,"MODU:B132:118:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:118:MODEL") field(FLNK, "MODU:B132:118:NCHAN") } record(longout, "MODU:B132:118:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:118:NCHAN_CALC") field(FLNK, "MODU:B132:118:NSLOT_CALC") } record(calc,"MODU:B132:118:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:118:MODEL") field(FLNK, "MODU:B132:118:NSLOT") } record(longout, "MODU:B132:118:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:118:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:118:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:118:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "18") field(PINI, "YES") } record(mbbo, "MODU:B132:119:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "1") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:119:NCHAN_CALC") } record(calc,"MODU:B132:119:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:119:MODEL") field(FLNK, "MODU:B132:119:NCHAN") } record(longout, "MODU:B132:119:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:119:NCHAN_CALC") field(FLNK, "MODU:B132:119:NSLOT_CALC") } record(calc,"MODU:B132:119:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:119:MODEL") field(FLNK, "MODU:B132:119:NSLOT") } record(longout, "MODU:B132:119:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:119:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:119:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:119:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "19") field(PINI, "YES") } record(mbbo, "MODU:B132:120:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "0") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:120:NCHAN_CALC") } record(calc,"MODU:B132:120:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:120:MODEL") field(FLNK, "MODU:B132:120:NCHAN") } record(longout, "MODU:B132:120:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:120:NCHAN_CALC") field(FLNK, "MODU:B132:120:NSLOT_CALC") } record(calc,"MODU:B132:120:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:120:MODEL") field(FLNK, "MODU:B132:120:NSLOT") } record(longout, "MODU:B132:120:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:120:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:120:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:120:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "20") field(PINI, "YES") } record(mbbo, "MODU:B132:121:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "0") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:121:NCHAN_CALC") } record(calc,"MODU:B132:121:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:121:MODEL") field(FLNK, "MODU:B132:121:NCHAN") } record(longout, "MODU:B132:121:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:121:NCHAN_CALC") field(FLNK, "MODU:B132:121:NSLOT_CALC") } record(calc,"MODU:B132:121:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:121:MODEL") field(FLNK, "MODU:B132:121:NSLOT") } record(longout, "MODU:B132:121:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:121:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:121:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:121:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "21") field(PINI, "YES") } record(mbbo, "MODU:B132:122:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "6") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:122:NCHAN_CALC") } record(calc,"MODU:B132:122:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:122:MODEL") field(FLNK, "MODU:B132:122:NCHAN") } record(longout, "MODU:B132:122:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:122:NCHAN_CALC") field(FLNK, "MODU:B132:122:NSLOT_CALC") } record(calc,"MODU:B132:122:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:122:MODEL") field(FLNK, "MODU:B132:122:NSLOT") } record(longout, "MODU:B132:122:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:122:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:122:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:122:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "22") field(PINI, "YES") } record(mbbo, "MODU:B132:123:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "0") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:123:NCHAN_CALC") } record(calc,"MODU:B132:123:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:123:MODEL") field(FLNK, "MODU:B132:123:NCHAN") } record(longout, "MODU:B132:123:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:123:NCHAN_CALC") field(FLNK, "MODU:B132:123:NSLOT_CALC") } record(calc,"MODU:B132:123:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:123:MODEL") field(FLNK, "MODU:B132:123:NSLOT") } record(longout, "MODU:B132:123:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:123:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:123:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:123:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "23") field(PINI, "YES") } record(mbbo, "MODU:B132:124:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "0") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:124:NCHAN_CALC") } record(calc,"MODU:B132:124:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:124:MODEL") field(FLNK, "MODU:B132:124:NCHAN") } record(longout, "MODU:B132:124:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:124:NCHAN_CALC") field(FLNK, "MODU:B132:124:NSLOT_CALC") } record(calc,"MODU:B132:124:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:124:MODEL") field(FLNK, "MODU:B132:124:NSLOT") } record(longout, "MODU:B132:124:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:124:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:124:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:124:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "24") field(PINI, "YES") } record(mbbo, "MODU:B132:125:MODEL") { field(DESC, "Module Model Name") field(DTYP, "Raw Soft Channel") field(PINI, "YES") field(VAL, "0") field(NOBT, "4") field(ZRST, "Unused") field(ONST, "SAM-123-603") field(TWST, "IDIM") field(THST, "IDOM") field(FRST, "PPOM") field(FVST, "PIOP") field(SXST, "Crate-Verifier") field(SVST, "DAC") field(EIST, "STB") field(NIST, "PDU-II") field(UNSV, "INVALID") field(FLNK, "MODU:B132:125:NCHAN_CALC") } record(calc,"MODU:B132:125:NCHAN_CALC") { field(DESC, "Get no of channels") field(ASG, "Internal") field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0") field(INPA, "MODU:B132:125:MODEL") field(FLNK, "MODU:B132:125:NCHAN") } record(longout, "MODU:B132:125:NCHAN") { field(DESC, "No of Channels") field(EGU, "No of Channels") field(DRVH, "32") field(HOPR, "32") field(OMSL, "closed_loop") field(DOL, "MODU:B132:125:NCHAN_CALC") field(FLNK, "MODU:B132:125:NSLOT_CALC") } record(calc,"MODU:B132:125:NSLOT_CALC") { field(DESC, "Get module width") field(ASG, "Internal") field(CALC, "A<9?1:2") field(INPA, "MODU:B132:125:MODEL") field(FLNK, "MODU:B132:125:NSLOT") } record(longout, "MODU:B132:125:NSLOT") { field(DESC, "Module Width") field(EGU, "Module Width") field(DRVH, "2") field(HOPR, "2") field(OMSL, "closed_loop") field(DOL, "MODU:B132:125:NSLOT_CALC") } # Currently, these are found in IOCManager record(longout, "MODU:B132:125:CRATE") { field(DESC, "Crate location") field(EGU, "Crate No.") field(DRVH, "15") field(HOPR, "15") field(DOL, "1") field(PINI, "YES") } record(longout, "MODU:B132:125:SLOT") { field(DESC, "Slot location") field(EGU, "Slot No.") field(DRVH, "25") field(HOPR, "25") field(LOPR, "0") field(DRVL, "0") field(DOL, "25") field(PINI, "YES") }