record(stringin, "ACSW:B913:NW03:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:B913:NW03) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINFO")
}

record(stringin, "ACSW:B913:NW03:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:B913:NW03) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(stringin, "ACSW:B913:NW03:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:B913:NW03:NETFWVERSION")
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:B913:NW03:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:B913:NW03:SITEID")
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:B913:NW03:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:B913:NW03:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:B913:NW03) acsw-b913-nw03")
}

record(stringin, "ACSW:B913:NW03:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:B913:NW03) acsw-b913-nw03")
}

record(ai, "ACSW:B913:NW03:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:B913:NW03:LOC") {
  field(PINI, "YES")
  field(VAL, "B913-2124")
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:B913:NW03:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-b913-nw03")
}

record(calcout, "ACSW:B913:NW03:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:B913:NW03:DISCONN.DISA")
  field(INPB, "ACSW:B913:NW03:DISCONN.DISV")
  field(INPC, "ACSW:B913:NW03:GETSTATUS.DISA")
  field(INPD, "ACSW:B913:NW03:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:B913:NW03:CONNSTA PP")
}

record(bi, "ACSW:B913:NW03:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:B913:NW03:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:B913:NW03:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:B913:NW03:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:B913:NW03:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:B913:NW03:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:B913:NW03:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:B913:NW03:UPTIMEHOUR") {
  field(FLNK, "ACSW:B913:NW03:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:B913:NW03:UPTIMEDAY") {
  field(FLNK, "ACSW:B913:NW03:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:B913:NW03:UPTIMEMINUTE") {
  field(FLNK, "ACSW:B913:NW03:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:B913:NW03:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:1POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW03:1POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW03:1POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW03:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW03:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW03:1POWERSTATE")
}

record(mbbi, "ACSW:B913:NW03:1POWERSTATE") {
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW03:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-b913-nw03")
}

record(stringin, "ACSW:B913:NW03:1NAMESET") {
  field(FLNK, "ACSW:B913:NW03:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW03:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-b913-nw03")
  field(DOL, "ACSW:B913:NW03:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW03:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(bo, "ACSW:B913:NW03:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(stringin, "ACSW:B913:NW03:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW03:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW03:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW03:1INITSTATE")
}

record(mbbi, "ACSW:B913:NW03:1INITSTATE") {
#  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW03:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:2POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW03:2POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW03:2POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW03:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW03:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW03:2POWERSTATE")
}

record(mbbi, "ACSW:B913:NW03:2POWERSTATE") {
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW03:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-b913-nw03")
}

record(stringin, "ACSW:B913:NW03:2NAMESET") {
  field(FLNK, "ACSW:B913:NW03:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW03:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-b913-nw03")
  field(DOL, "ACSW:B913:NW03:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW03:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(bo, "ACSW:B913:NW03:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(stringin, "ACSW:B913:NW03:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW03:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW03:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW03:2INITSTATE")
}

record(mbbi, "ACSW:B913:NW03:2INITSTATE") {
#  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW03:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:3POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW03:3POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW03:3POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW03:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW03:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW03:3POWERSTATE")
}

record(mbbi, "ACSW:B913:NW03:3POWERSTATE") {
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW03:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-b913-nw03")
}

record(stringin, "ACSW:B913:NW03:3NAMESET") {
  field(FLNK, "ACSW:B913:NW03:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW03:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-b913-nw03")
  field(DOL, "ACSW:B913:NW03:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW03:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(bo, "ACSW:B913:NW03:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(stringin, "ACSW:B913:NW03:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW03:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW03:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW03:3INITSTATE")
}

record(mbbi, "ACSW:B913:NW03:3INITSTATE") {
#  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW03:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:4POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW03:4POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW03:4POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW03:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW03:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW03:4POWERSTATE")
}

record(mbbi, "ACSW:B913:NW03:4POWERSTATE") {
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW03:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-b913-nw03")
}

record(stringin, "ACSW:B913:NW03:4NAMESET") {
  field(FLNK, "ACSW:B913:NW03:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW03:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-b913-nw03")
  field(DOL, "ACSW:B913:NW03:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW03:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(bo, "ACSW:B913:NW03:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(stringin, "ACSW:B913:NW03:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW03:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW03:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW03:4INITSTATE")
}

record(mbbi, "ACSW:B913:NW03:4INITSTATE") {
#  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW03:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:5POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW03:5POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW03:5POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW03:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW03:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW03:5POWERSTATE")
}

record(mbbi, "ACSW:B913:NW03:5POWERSTATE") {
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW03:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-b913-nw03")
}

record(stringin, "ACSW:B913:NW03:5NAMESET") {
  field(FLNK, "ACSW:B913:NW03:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW03:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-b913-nw03")
  field(DOL, "ACSW:B913:NW03:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW03:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(bo, "ACSW:B913:NW03:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(stringin, "ACSW:B913:NW03:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW03:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW03:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW03:5INITSTATE")
}

record(mbbi, "ACSW:B913:NW03:5INITSTATE") {
#  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW03:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:6POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW03:6POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW03:6POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW03:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW03:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW03:6POWERSTATE")
}

record(mbbi, "ACSW:B913:NW03:6POWERSTATE") {
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW03:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-b913-nw03")
}

record(stringin, "ACSW:B913:NW03:6NAMESET") {
  field(FLNK, "ACSW:B913:NW03:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW03:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-b913-nw03")
  field(DOL, "ACSW:B913:NW03:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW03:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(bo, "ACSW:B913:NW03:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(stringin, "ACSW:B913:NW03:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW03:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW03:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW03:6INITSTATE")
}

record(mbbi, "ACSW:B913:NW03:6INITSTATE") {
#  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW03:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:7POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW03:7POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW03:7POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW03:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW03:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW03:7POWERSTATE")
}

record(mbbi, "ACSW:B913:NW03:7POWERSTATE") {
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW03:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-b913-nw03")
}

record(stringin, "ACSW:B913:NW03:7NAMESET") {
  field(FLNK, "ACSW:B913:NW03:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW03:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-b913-nw03")
  field(DOL, "ACSW:B913:NW03:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW03:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(bo, "ACSW:B913:NW03:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(stringin, "ACSW:B913:NW03:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW03:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW03:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW03:7INITSTATE")
}

record(mbbi, "ACSW:B913:NW03:7INITSTATE") {
#  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW03:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:8POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW03:8POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW03:8POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW03:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW03:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW03:8POWERSTATE")
}

record(mbbi, "ACSW:B913:NW03:8POWERSTATE") {
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW03:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-b913-nw03")
}

record(bo, "ACSW:B913:NW03:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-b913-nw03")
}

record(stringin, "ACSW:B913:NW03:8NAMESET") {
  field(FLNK, "ACSW:B913:NW03:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW03:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-b913-nw03")
  field(DOL, "ACSW:B913:NW03:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW03:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(bo, "ACSW:B913:NW03:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-b913-nw03")
  field(FLNK, "ACSW:B913:NW03:GETINIT")
}

record(stringin, "ACSW:B913:NW03:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW03:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW03:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW03:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW03:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW03:8INITSTATE")
}

record(mbbi, "ACSW:B913:NW03:8INITSTATE") {
#  field(SDIS, "ACSW:B913:NW03:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW03:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW05:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:B913:NW05) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINFO")
}

record(stringin, "ACSW:B913:NW05:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:B913:NW05) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(stringin, "ACSW:B913:NW05:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:B913:NW05:NETFWVERSION")
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:B913:NW05:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:B913:NW05:SITEID")
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:B913:NW05:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:B913:NW05:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:B913:NW05) acsw-b913-nw05")
}

record(stringin, "ACSW:B913:NW05:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:B913:NW05) acsw-b913-nw05")
}

record(ai, "ACSW:B913:NW05:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:B913:NW05:LOC") {
  field(PINI, "YES")
  field(VAL, "B913-1114")
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:B913:NW05:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-b913-nw05")
}

record(calcout, "ACSW:B913:NW05:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:B913:NW05:DISCONN.DISA")
  field(INPB, "ACSW:B913:NW05:DISCONN.DISV")
  field(INPC, "ACSW:B913:NW05:GETSTATUS.DISA")
  field(INPD, "ACSW:B913:NW05:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:B913:NW05:CONNSTA PP")
}

record(bi, "ACSW:B913:NW05:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:B913:NW05:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:B913:NW05:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:B913:NW05:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:B913:NW05:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:B913:NW05:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:B913:NW05:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:B913:NW05:UPTIMEHOUR") {
  field(FLNK, "ACSW:B913:NW05:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:B913:NW05:UPTIMEDAY") {
  field(FLNK, "ACSW:B913:NW05:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:B913:NW05:UPTIMEMINUTE") {
  field(FLNK, "ACSW:B913:NW05:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:B913:NW05:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:1POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW05:1POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW05:1POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW05:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW05:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW05:1POWERSTATE")
}

record(mbbi, "ACSW:B913:NW05:1POWERSTATE") {
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW05:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-b913-nw05")
}

record(stringin, "ACSW:B913:NW05:1NAMESET") {
  field(FLNK, "ACSW:B913:NW05:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW05:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-b913-nw05")
  field(DOL, "ACSW:B913:NW05:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW05:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(bo, "ACSW:B913:NW05:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(stringin, "ACSW:B913:NW05:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW05:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW05:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW05:1INITSTATE")
}

record(mbbi, "ACSW:B913:NW05:1INITSTATE") {
#  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW05:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:2POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW05:2POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW05:2POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW05:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW05:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW05:2POWERSTATE")
}

record(mbbi, "ACSW:B913:NW05:2POWERSTATE") {
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW05:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-b913-nw05")
}

record(stringin, "ACSW:B913:NW05:2NAMESET") {
  field(FLNK, "ACSW:B913:NW05:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW05:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-b913-nw05")
  field(DOL, "ACSW:B913:NW05:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW05:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(bo, "ACSW:B913:NW05:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(stringin, "ACSW:B913:NW05:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW05:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW05:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW05:2INITSTATE")
}

record(mbbi, "ACSW:B913:NW05:2INITSTATE") {
#  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW05:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:3POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW05:3POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW05:3POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW05:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW05:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW05:3POWERSTATE")
}

record(mbbi, "ACSW:B913:NW05:3POWERSTATE") {
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW05:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-b913-nw05")
}

record(stringin, "ACSW:B913:NW05:3NAMESET") {
  field(FLNK, "ACSW:B913:NW05:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW05:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-b913-nw05")
  field(DOL, "ACSW:B913:NW05:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW05:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(bo, "ACSW:B913:NW05:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(stringin, "ACSW:B913:NW05:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW05:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW05:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW05:3INITSTATE")
}

record(mbbi, "ACSW:B913:NW05:3INITSTATE") {
#  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW05:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:4POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW05:4POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW05:4POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW05:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW05:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW05:4POWERSTATE")
}

record(mbbi, "ACSW:B913:NW05:4POWERSTATE") {
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW05:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-b913-nw05")
}

record(stringin, "ACSW:B913:NW05:4NAMESET") {
  field(FLNK, "ACSW:B913:NW05:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW05:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-b913-nw05")
  field(DOL, "ACSW:B913:NW05:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW05:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(bo, "ACSW:B913:NW05:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(stringin, "ACSW:B913:NW05:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW05:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW05:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW05:4INITSTATE")
}

record(mbbi, "ACSW:B913:NW05:4INITSTATE") {
#  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW05:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:5POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW05:5POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW05:5POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW05:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW05:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW05:5POWERSTATE")
}

record(mbbi, "ACSW:B913:NW05:5POWERSTATE") {
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW05:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-b913-nw05")
}

record(stringin, "ACSW:B913:NW05:5NAMESET") {
  field(FLNK, "ACSW:B913:NW05:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW05:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-b913-nw05")
  field(DOL, "ACSW:B913:NW05:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW05:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(bo, "ACSW:B913:NW05:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(stringin, "ACSW:B913:NW05:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW05:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW05:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW05:5INITSTATE")
}

record(mbbi, "ACSW:B913:NW05:5INITSTATE") {
#  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW05:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:6POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW05:6POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW05:6POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW05:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW05:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW05:6POWERSTATE")
}

record(mbbi, "ACSW:B913:NW05:6POWERSTATE") {
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW05:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-b913-nw05")
}

record(stringin, "ACSW:B913:NW05:6NAMESET") {
  field(FLNK, "ACSW:B913:NW05:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW05:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-b913-nw05")
  field(DOL, "ACSW:B913:NW05:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW05:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(bo, "ACSW:B913:NW05:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(stringin, "ACSW:B913:NW05:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW05:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW05:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW05:6INITSTATE")
}

record(mbbi, "ACSW:B913:NW05:6INITSTATE") {
#  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW05:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:7POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW05:7POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW05:7POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW05:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW05:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW05:7POWERSTATE")
}

record(mbbi, "ACSW:B913:NW05:7POWERSTATE") {
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW05:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-b913-nw05")
}

record(stringin, "ACSW:B913:NW05:7NAMESET") {
  field(FLNK, "ACSW:B913:NW05:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW05:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-b913-nw05")
  field(DOL, "ACSW:B913:NW05:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW05:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(bo, "ACSW:B913:NW05:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(stringin, "ACSW:B913:NW05:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW05:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW05:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW05:7INITSTATE")
}

record(mbbi, "ACSW:B913:NW05:7INITSTATE") {
#  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW05:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:8POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW05:8POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW05:8POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW05:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW05:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW05:8POWERSTATE")
}

record(mbbi, "ACSW:B913:NW05:8POWERSTATE") {
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW05:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-b913-nw05")
}

record(bo, "ACSW:B913:NW05:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-b913-nw05")
}

record(stringin, "ACSW:B913:NW05:8NAMESET") {
  field(FLNK, "ACSW:B913:NW05:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW05:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-b913-nw05")
  field(DOL, "ACSW:B913:NW05:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW05:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(bo, "ACSW:B913:NW05:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-b913-nw05")
  field(FLNK, "ACSW:B913:NW05:GETINIT")
}

record(stringin, "ACSW:B913:NW05:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW05:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW05:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW05:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW05:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW05:8INITSTATE")
}

record(mbbi, "ACSW:B913:NW05:8INITSTATE") {
#  field(SDIS, "ACSW:B913:NW05:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW05:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW08:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:B913:NW08) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINFO")
}

record(stringin, "ACSW:B913:NW08:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:B913:NW08) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(stringin, "ACSW:B913:NW08:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:B913:NW08:NETFWVERSION")
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:B913:NW08:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:B913:NW08:SITEID")
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:B913:NW08:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:B913:NW08:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:B913:NW08) acsw-b913-nw08")
}

record(stringin, "ACSW:B913:NW08:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:B913:NW08) acsw-b913-nw08")
}

record(ai, "ACSW:B913:NW08:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:B913:NW08:LOC") {
  field(PINI, "YES")
  field(VAL, "B913-93")
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:B913:NW08:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-b913-nw08")
}

record(calcout, "ACSW:B913:NW08:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:B913:NW08:DISCONN.DISA")
  field(INPB, "ACSW:B913:NW08:DISCONN.DISV")
  field(INPC, "ACSW:B913:NW08:GETSTATUS.DISA")
  field(INPD, "ACSW:B913:NW08:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:B913:NW08:CONNSTA PP")
}

record(bi, "ACSW:B913:NW08:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:B913:NW08:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:B913:NW08:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:B913:NW08:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:B913:NW08:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:B913:NW08:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:B913:NW08:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:B913:NW08:UPTIMEHOUR") {
  field(FLNK, "ACSW:B913:NW08:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:B913:NW08:UPTIMEDAY") {
  field(FLNK, "ACSW:B913:NW08:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:B913:NW08:UPTIMEMINUTE") {
  field(FLNK, "ACSW:B913:NW08:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:B913:NW08:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:1POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW08:1POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW08:1POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW08:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW08:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW08:1POWERSTATE")
}

record(mbbi, "ACSW:B913:NW08:1POWERSTATE") {
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW08:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-b913-nw08")
}

record(stringin, "ACSW:B913:NW08:1NAMESET") {
  field(FLNK, "ACSW:B913:NW08:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW08:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-b913-nw08")
  field(DOL, "ACSW:B913:NW08:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW08:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(bo, "ACSW:B913:NW08:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(stringin, "ACSW:B913:NW08:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW08:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW08:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW08:1INITSTATE")
}

record(mbbi, "ACSW:B913:NW08:1INITSTATE") {
#  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW08:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:2POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW08:2POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW08:2POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW08:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW08:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW08:2POWERSTATE")
}

record(mbbi, "ACSW:B913:NW08:2POWERSTATE") {
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW08:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-b913-nw08")
}

record(stringin, "ACSW:B913:NW08:2NAMESET") {
  field(FLNK, "ACSW:B913:NW08:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW08:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-b913-nw08")
  field(DOL, "ACSW:B913:NW08:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW08:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(bo, "ACSW:B913:NW08:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(stringin, "ACSW:B913:NW08:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW08:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW08:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW08:2INITSTATE")
}

record(mbbi, "ACSW:B913:NW08:2INITSTATE") {
#  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW08:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:3POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW08:3POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW08:3POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW08:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW08:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW08:3POWERSTATE")
}

record(mbbi, "ACSW:B913:NW08:3POWERSTATE") {
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW08:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-b913-nw08")
}

record(stringin, "ACSW:B913:NW08:3NAMESET") {
  field(FLNK, "ACSW:B913:NW08:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW08:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-b913-nw08")
  field(DOL, "ACSW:B913:NW08:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW08:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(bo, "ACSW:B913:NW08:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(stringin, "ACSW:B913:NW08:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW08:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW08:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW08:3INITSTATE")
}

record(mbbi, "ACSW:B913:NW08:3INITSTATE") {
#  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW08:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:4POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW08:4POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW08:4POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW08:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW08:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW08:4POWERSTATE")
}

record(mbbi, "ACSW:B913:NW08:4POWERSTATE") {
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW08:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-b913-nw08")
}

record(stringin, "ACSW:B913:NW08:4NAMESET") {
  field(FLNK, "ACSW:B913:NW08:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW08:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-b913-nw08")
  field(DOL, "ACSW:B913:NW08:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW08:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(bo, "ACSW:B913:NW08:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(stringin, "ACSW:B913:NW08:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW08:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW08:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW08:4INITSTATE")
}

record(mbbi, "ACSW:B913:NW08:4INITSTATE") {
#  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW08:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:5POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW08:5POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW08:5POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW08:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW08:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW08:5POWERSTATE")
}

record(mbbi, "ACSW:B913:NW08:5POWERSTATE") {
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW08:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-b913-nw08")
}

record(stringin, "ACSW:B913:NW08:5NAMESET") {
  field(FLNK, "ACSW:B913:NW08:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW08:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-b913-nw08")
  field(DOL, "ACSW:B913:NW08:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW08:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(bo, "ACSW:B913:NW08:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(stringin, "ACSW:B913:NW08:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW08:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW08:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW08:5INITSTATE")
}

record(mbbi, "ACSW:B913:NW08:5INITSTATE") {
#  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW08:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:6POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW08:6POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW08:6POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW08:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW08:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW08:6POWERSTATE")
}

record(mbbi, "ACSW:B913:NW08:6POWERSTATE") {
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW08:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-b913-nw08")
}

record(stringin, "ACSW:B913:NW08:6NAMESET") {
  field(FLNK, "ACSW:B913:NW08:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW08:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-b913-nw08")
  field(DOL, "ACSW:B913:NW08:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW08:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(bo, "ACSW:B913:NW08:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(stringin, "ACSW:B913:NW08:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW08:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW08:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW08:6INITSTATE")
}

record(mbbi, "ACSW:B913:NW08:6INITSTATE") {
#  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW08:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:7POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW08:7POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW08:7POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW08:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW08:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW08:7POWERSTATE")
}

record(mbbi, "ACSW:B913:NW08:7POWERSTATE") {
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW08:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-b913-nw08")
}

record(stringin, "ACSW:B913:NW08:7NAMESET") {
  field(FLNK, "ACSW:B913:NW08:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW08:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-b913-nw08")
  field(DOL, "ACSW:B913:NW08:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW08:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(bo, "ACSW:B913:NW08:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(stringin, "ACSW:B913:NW08:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW08:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW08:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW08:7INITSTATE")
}

record(mbbi, "ACSW:B913:NW08:7INITSTATE") {
#  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW08:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:8POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW08:8POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW08:8POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW08:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW08:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW08:8POWERSTATE")
}

record(mbbi, "ACSW:B913:NW08:8POWERSTATE") {
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW08:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-b913-nw08")
}

record(bo, "ACSW:B913:NW08:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-b913-nw08")
}

record(stringin, "ACSW:B913:NW08:8NAMESET") {
  field(FLNK, "ACSW:B913:NW08:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW08:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-b913-nw08")
  field(DOL, "ACSW:B913:NW08:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW08:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(bo, "ACSW:B913:NW08:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-b913-nw08")
  field(FLNK, "ACSW:B913:NW08:GETINIT")
}

record(stringin, "ACSW:B913:NW08:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW08:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW08:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW08:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW08:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW08:8INITSTATE")
}

record(mbbi, "ACSW:B913:NW08:8INITSTATE") {
#  field(SDIS, "ACSW:B913:NW08:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW08:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW09:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:B913:NW09) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINFO")
}

record(stringin, "ACSW:B913:NW09:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:B913:NW09) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(stringin, "ACSW:B913:NW09:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:B913:NW09:NETFWVERSION")
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:B913:NW09:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:B913:NW09:SITEID")
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:B913:NW09:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:B913:NW09:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:B913:NW09) acsw-b913-nw09")
}

record(stringin, "ACSW:B913:NW09:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:B913:NW09) acsw-b913-nw09")
}

record(ai, "ACSW:B913:NW09:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:B913:NW09:LOC") {
  field(PINI, "YES")
  field(VAL, "B913-1532")
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:B913:NW09:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-b913-nw09")
}

record(calcout, "ACSW:B913:NW09:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:B913:NW09:DISCONN.DISA")
  field(INPB, "ACSW:B913:NW09:DISCONN.DISV")
  field(INPC, "ACSW:B913:NW09:GETSTATUS.DISA")
  field(INPD, "ACSW:B913:NW09:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:B913:NW09:CONNSTA PP")
}

record(bi, "ACSW:B913:NW09:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:B913:NW09:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:B913:NW09:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:B913:NW09:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:B913:NW09:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:B913:NW09:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:B913:NW09:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:B913:NW09:UPTIMEHOUR") {
  field(FLNK, "ACSW:B913:NW09:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:B913:NW09:UPTIMEDAY") {
  field(FLNK, "ACSW:B913:NW09:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:B913:NW09:UPTIMEMINUTE") {
  field(FLNK, "ACSW:B913:NW09:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:B913:NW09:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:1POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW09:1POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW09:1POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW09:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW09:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW09:1POWERSTATE")
}

record(mbbi, "ACSW:B913:NW09:1POWERSTATE") {
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW09:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-b913-nw09")
}

record(stringin, "ACSW:B913:NW09:1NAMESET") {
  field(FLNK, "ACSW:B913:NW09:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW09:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-b913-nw09")
  field(DOL, "ACSW:B913:NW09:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW09:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(bo, "ACSW:B913:NW09:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(stringin, "ACSW:B913:NW09:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW09:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW09:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW09:1INITSTATE")
}

record(mbbi, "ACSW:B913:NW09:1INITSTATE") {
#  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW09:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:2POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW09:2POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW09:2POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW09:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW09:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW09:2POWERSTATE")
}

record(mbbi, "ACSW:B913:NW09:2POWERSTATE") {
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW09:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-b913-nw09")
}

record(stringin, "ACSW:B913:NW09:2NAMESET") {
  field(FLNK, "ACSW:B913:NW09:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW09:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-b913-nw09")
  field(DOL, "ACSW:B913:NW09:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW09:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(bo, "ACSW:B913:NW09:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(stringin, "ACSW:B913:NW09:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW09:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW09:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW09:2INITSTATE")
}

record(mbbi, "ACSW:B913:NW09:2INITSTATE") {
#  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW09:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:3POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW09:3POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW09:3POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW09:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW09:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW09:3POWERSTATE")
}

record(mbbi, "ACSW:B913:NW09:3POWERSTATE") {
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW09:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-b913-nw09")
}

record(stringin, "ACSW:B913:NW09:3NAMESET") {
  field(FLNK, "ACSW:B913:NW09:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW09:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-b913-nw09")
  field(DOL, "ACSW:B913:NW09:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW09:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(bo, "ACSW:B913:NW09:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(stringin, "ACSW:B913:NW09:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW09:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW09:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW09:3INITSTATE")
}

record(mbbi, "ACSW:B913:NW09:3INITSTATE") {
#  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW09:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:4POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW09:4POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW09:4POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW09:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW09:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW09:4POWERSTATE")
}

record(mbbi, "ACSW:B913:NW09:4POWERSTATE") {
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW09:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-b913-nw09")
}

record(stringin, "ACSW:B913:NW09:4NAMESET") {
  field(FLNK, "ACSW:B913:NW09:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW09:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-b913-nw09")
  field(DOL, "ACSW:B913:NW09:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW09:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(bo, "ACSW:B913:NW09:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(stringin, "ACSW:B913:NW09:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW09:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW09:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW09:4INITSTATE")
}

record(mbbi, "ACSW:B913:NW09:4INITSTATE") {
#  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW09:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:5POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW09:5POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW09:5POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW09:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW09:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW09:5POWERSTATE")
}

record(mbbi, "ACSW:B913:NW09:5POWERSTATE") {
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW09:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-b913-nw09")
}

record(stringin, "ACSW:B913:NW09:5NAMESET") {
  field(FLNK, "ACSW:B913:NW09:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW09:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-b913-nw09")
  field(DOL, "ACSW:B913:NW09:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW09:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(bo, "ACSW:B913:NW09:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(stringin, "ACSW:B913:NW09:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW09:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW09:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW09:5INITSTATE")
}

record(mbbi, "ACSW:B913:NW09:5INITSTATE") {
#  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW09:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:6POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW09:6POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW09:6POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW09:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW09:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW09:6POWERSTATE")
}

record(mbbi, "ACSW:B913:NW09:6POWERSTATE") {
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW09:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-b913-nw09")
}

record(stringin, "ACSW:B913:NW09:6NAMESET") {
  field(FLNK, "ACSW:B913:NW09:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW09:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-b913-nw09")
  field(DOL, "ACSW:B913:NW09:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW09:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(bo, "ACSW:B913:NW09:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(stringin, "ACSW:B913:NW09:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW09:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW09:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW09:6INITSTATE")
}

record(mbbi, "ACSW:B913:NW09:6INITSTATE") {
#  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW09:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:7POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW09:7POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW09:7POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW09:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW09:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW09:7POWERSTATE")
}

record(mbbi, "ACSW:B913:NW09:7POWERSTATE") {
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW09:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-b913-nw09")
}

record(stringin, "ACSW:B913:NW09:7NAMESET") {
  field(FLNK, "ACSW:B913:NW09:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW09:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-b913-nw09")
  field(DOL, "ACSW:B913:NW09:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW09:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(bo, "ACSW:B913:NW09:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(stringin, "ACSW:B913:NW09:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW09:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW09:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW09:7INITSTATE")
}

record(mbbi, "ACSW:B913:NW09:7INITSTATE") {
#  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:B913:NW09:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:8POWERSTATEIN")
}

record(stringin, "ACSW:B913:NW09:8POWERSTATEIN") {
  field(FLNK, "ACSW:B913:NW09:8POWERSTATESV")
}

record(scalcout, "ACSW:B913:NW09:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:B913:NW09:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:B913:NW09:8POWERSTATE")
}

record(mbbi, "ACSW:B913:NW09:8POWERSTATE") {
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:B913:NW09:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-b913-nw09")
}

record(bo, "ACSW:B913:NW09:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-b913-nw09")
}

record(stringin, "ACSW:B913:NW09:8NAMESET") {
  field(FLNK, "ACSW:B913:NW09:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:B913:NW09:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-b913-nw09")
  field(DOL, "ACSW:B913:NW09:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:B913:NW09:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(bo, "ACSW:B913:NW09:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-b913-nw09")
  field(FLNK, "ACSW:B913:NW09:GETINIT")
}

record(stringin, "ACSW:B913:NW09:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:B913:NW09:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:B913:NW09:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:B913:NW09:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:B913:NW09:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:B913:NW09:8INITSTATE")
}

record(mbbi, "ACSW:B913:NW09:8INITSTATE") {
#  field(SDIS, "ACSW:B913:NW09:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:B913:NW09:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW14:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW14) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINFO")
}

record(stringin, "ACSW:UNDH:NW14:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW14) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(stringin, "ACSW:UNDH:NW14:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW14:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW14:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW14:SITEID")
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW14:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW14:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW14) acsw-undh-nw14")
}

record(stringin, "ACSW:UNDH:NW14:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW14) acsw-undh-nw14")
}

record(ai, "ACSW:UNDH:NW14:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW14:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-14H")
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW14:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw14")
}

record(calcout, "ACSW:UNDH:NW14:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW14:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW14:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW14:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW14:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW14:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW14:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW14:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW14:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW14:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW14:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW14:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW14:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW14:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW14:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW14:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW14:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW14:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW14:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW14:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW14:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW14:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW14:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW14:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW14:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW14:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw14")
}

record(stringin, "ACSW:UNDH:NW14:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW14:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW14:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw14")
  field(DOL, "ACSW:UNDH:NW14:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW14:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(bo, "ACSW:UNDH:NW14:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(stringin, "ACSW:UNDH:NW14:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW14:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW14:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW14:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW14:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW14:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW14:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW14:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW14:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW14:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW14:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw14")
}

record(stringin, "ACSW:UNDH:NW14:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW14:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW14:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw14")
  field(DOL, "ACSW:UNDH:NW14:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW14:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(bo, "ACSW:UNDH:NW14:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(stringin, "ACSW:UNDH:NW14:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW14:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW14:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW14:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW14:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW14:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW14:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW14:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW14:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW14:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW14:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw14")
}

record(stringin, "ACSW:UNDH:NW14:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW14:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW14:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw14")
  field(DOL, "ACSW:UNDH:NW14:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW14:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(bo, "ACSW:UNDH:NW14:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(stringin, "ACSW:UNDH:NW14:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW14:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW14:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW14:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW14:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW14:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW14:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW14:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW14:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW14:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW14:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw14")
}

record(stringin, "ACSW:UNDH:NW14:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW14:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW14:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw14")
  field(DOL, "ACSW:UNDH:NW14:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW14:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(bo, "ACSW:UNDH:NW14:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(stringin, "ACSW:UNDH:NW14:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW14:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW14:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW14:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW14:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW14:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW14:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW14:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW14:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW14:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW14:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw14")
}

record(stringin, "ACSW:UNDH:NW14:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW14:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW14:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw14")
  field(DOL, "ACSW:UNDH:NW14:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW14:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(bo, "ACSW:UNDH:NW14:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(stringin, "ACSW:UNDH:NW14:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW14:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW14:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW14:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW14:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW14:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW14:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW14:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW14:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW14:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW14:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw14")
}

record(stringin, "ACSW:UNDH:NW14:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW14:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW14:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw14")
  field(DOL, "ACSW:UNDH:NW14:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW14:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(bo, "ACSW:UNDH:NW14:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(stringin, "ACSW:UNDH:NW14:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW14:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW14:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW14:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW14:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW14:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW14:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW14:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW14:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW14:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW14:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw14")
}

record(stringin, "ACSW:UNDH:NW14:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW14:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW14:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw14")
  field(DOL, "ACSW:UNDH:NW14:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW14:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(bo, "ACSW:UNDH:NW14:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(stringin, "ACSW:UNDH:NW14:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW14:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW14:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW14:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW14:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW14:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW14:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW14:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW14:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW14:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW14:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw14")
}

record(bo, "ACSW:UNDH:NW14:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw14")
}

record(stringin, "ACSW:UNDH:NW14:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW14:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW14:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw14")
  field(DOL, "ACSW:UNDH:NW14:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW14:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(bo, "ACSW:UNDH:NW14:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw14")
  field(FLNK, "ACSW:UNDH:NW14:GETINIT")
}

record(stringin, "ACSW:UNDH:NW14:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW14:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW14:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW14:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW14:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW14:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW14:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW14:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW15:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW15) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINFO")
}

record(stringin, "ACSW:UNDH:NW15:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW15) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(stringin, "ACSW:UNDH:NW15:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW15:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW15:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW15:SITEID")
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW15:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW15:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW15) acsw-undh-nw15")
}

record(stringin, "ACSW:UNDH:NW15:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW15) acsw-undh-nw15")
}

record(ai, "ACSW:UNDH:NW15:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW15:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-15H")
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW15:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw15")
}

record(calcout, "ACSW:UNDH:NW15:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW15:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW15:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW15:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW15:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW15:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW15:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW15:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW15:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW15:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW15:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW15:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW15:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW15:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW15:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW15:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW15:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW15:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW15:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW15:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW15:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW15:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW15:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW15:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW15:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW15:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw15")
}

record(stringin, "ACSW:UNDH:NW15:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW15:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW15:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw15")
  field(DOL, "ACSW:UNDH:NW15:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW15:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(bo, "ACSW:UNDH:NW15:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(stringin, "ACSW:UNDH:NW15:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW15:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW15:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW15:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW15:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW15:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW15:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW15:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW15:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW15:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW15:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw15")
}

record(stringin, "ACSW:UNDH:NW15:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW15:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW15:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw15")
  field(DOL, "ACSW:UNDH:NW15:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW15:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(bo, "ACSW:UNDH:NW15:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(stringin, "ACSW:UNDH:NW15:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW15:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW15:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW15:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW15:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW15:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW15:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW15:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW15:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW15:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW15:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw15")
}

record(stringin, "ACSW:UNDH:NW15:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW15:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW15:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw15")
  field(DOL, "ACSW:UNDH:NW15:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW15:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(bo, "ACSW:UNDH:NW15:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(stringin, "ACSW:UNDH:NW15:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW15:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW15:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW15:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW15:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW15:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW15:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW15:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW15:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW15:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW15:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw15")
}

record(stringin, "ACSW:UNDH:NW15:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW15:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW15:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw15")
  field(DOL, "ACSW:UNDH:NW15:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW15:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(bo, "ACSW:UNDH:NW15:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(stringin, "ACSW:UNDH:NW15:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW15:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW15:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW15:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW15:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW15:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW15:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW15:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW15:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW15:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW15:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw15")
}

record(stringin, "ACSW:UNDH:NW15:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW15:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW15:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw15")
  field(DOL, "ACSW:UNDH:NW15:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW15:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(bo, "ACSW:UNDH:NW15:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(stringin, "ACSW:UNDH:NW15:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW15:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW15:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW15:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW15:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW15:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW15:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW15:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW15:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW15:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW15:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw15")
}

record(stringin, "ACSW:UNDH:NW15:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW15:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW15:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw15")
  field(DOL, "ACSW:UNDH:NW15:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW15:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(bo, "ACSW:UNDH:NW15:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(stringin, "ACSW:UNDH:NW15:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW15:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW15:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW15:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW15:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW15:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW15:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW15:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW15:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW15:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW15:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw15")
}

record(stringin, "ACSW:UNDH:NW15:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW15:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW15:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw15")
  field(DOL, "ACSW:UNDH:NW15:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW15:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(bo, "ACSW:UNDH:NW15:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(stringin, "ACSW:UNDH:NW15:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW15:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW15:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW15:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW15:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW15:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW15:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW15:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW15:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW15:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW15:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw15")
}

record(bo, "ACSW:UNDH:NW15:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw15")
}

record(stringin, "ACSW:UNDH:NW15:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW15:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW15:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw15")
  field(DOL, "ACSW:UNDH:NW15:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW15:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(bo, "ACSW:UNDH:NW15:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw15")
  field(FLNK, "ACSW:UNDH:NW15:GETINIT")
}

record(stringin, "ACSW:UNDH:NW15:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW15:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW15:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW15:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW15:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW15:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW15:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW15:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW16:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW16) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINFO")
}

record(stringin, "ACSW:UNDH:NW16:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW16) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(stringin, "ACSW:UNDH:NW16:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW16:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW16:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW16:SITEID")
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW16:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW16:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW16) acsw-undh-nw16")
}

record(stringin, "ACSW:UNDH:NW16:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW16) acsw-undh-nw16")
}

record(ai, "ACSW:UNDH:NW16:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW16:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-16H")
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW16:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw16")
}

record(calcout, "ACSW:UNDH:NW16:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW16:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW16:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW16:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW16:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW16:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW16:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW16:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW16:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW16:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW16:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW16:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW16:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW16:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW16:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW16:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW16:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW16:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW16:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW16:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW16:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW16:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW16:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW16:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW16:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW16:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw16")
}

record(stringin, "ACSW:UNDH:NW16:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW16:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW16:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw16")
  field(DOL, "ACSW:UNDH:NW16:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW16:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(bo, "ACSW:UNDH:NW16:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(stringin, "ACSW:UNDH:NW16:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW16:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW16:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW16:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW16:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW16:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW16:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW16:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW16:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW16:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW16:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw16")
}

record(stringin, "ACSW:UNDH:NW16:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW16:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW16:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw16")
  field(DOL, "ACSW:UNDH:NW16:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW16:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(bo, "ACSW:UNDH:NW16:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(stringin, "ACSW:UNDH:NW16:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW16:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW16:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW16:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW16:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW16:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW16:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW16:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW16:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW16:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW16:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw16")
}

record(stringin, "ACSW:UNDH:NW16:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW16:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW16:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw16")
  field(DOL, "ACSW:UNDH:NW16:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW16:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(bo, "ACSW:UNDH:NW16:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(stringin, "ACSW:UNDH:NW16:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW16:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW16:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW16:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW16:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW16:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW16:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW16:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW16:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW16:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW16:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw16")
}

record(stringin, "ACSW:UNDH:NW16:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW16:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW16:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw16")
  field(DOL, "ACSW:UNDH:NW16:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW16:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(bo, "ACSW:UNDH:NW16:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(stringin, "ACSW:UNDH:NW16:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW16:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW16:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW16:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW16:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW16:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW16:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW16:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW16:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW16:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW16:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw16")
}

record(stringin, "ACSW:UNDH:NW16:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW16:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW16:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw16")
  field(DOL, "ACSW:UNDH:NW16:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW16:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(bo, "ACSW:UNDH:NW16:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(stringin, "ACSW:UNDH:NW16:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW16:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW16:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW16:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW16:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW16:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW16:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW16:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW16:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW16:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW16:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw16")
}

record(stringin, "ACSW:UNDH:NW16:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW16:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW16:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw16")
  field(DOL, "ACSW:UNDH:NW16:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW16:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(bo, "ACSW:UNDH:NW16:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(stringin, "ACSW:UNDH:NW16:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW16:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW16:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW16:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW16:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW16:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW16:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW16:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW16:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW16:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW16:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw16")
}

record(stringin, "ACSW:UNDH:NW16:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW16:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW16:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw16")
  field(DOL, "ACSW:UNDH:NW16:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW16:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(bo, "ACSW:UNDH:NW16:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(stringin, "ACSW:UNDH:NW16:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW16:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW16:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW16:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW16:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW16:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW16:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW16:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW16:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW16:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW16:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw16")
}

record(bo, "ACSW:UNDH:NW16:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw16")
}

record(stringin, "ACSW:UNDH:NW16:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW16:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW16:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw16")
  field(DOL, "ACSW:UNDH:NW16:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW16:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(bo, "ACSW:UNDH:NW16:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw16")
  field(FLNK, "ACSW:UNDH:NW16:GETINIT")
}

record(stringin, "ACSW:UNDH:NW16:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW16:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW16:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW16:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW16:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW16:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW16:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW16:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW17:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW17) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINFO")
}

record(stringin, "ACSW:UNDH:NW17:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW17) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(stringin, "ACSW:UNDH:NW17:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW17:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW17:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW17:SITEID")
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW17:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW17:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW17) acsw-undh-nw17")
}

record(stringin, "ACSW:UNDH:NW17:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW17) acsw-undh-nw17")
}

record(ai, "ACSW:UNDH:NW17:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW17:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-17H")
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW17:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw17")
}

record(calcout, "ACSW:UNDH:NW17:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW17:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW17:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW17:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW17:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW17:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW17:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW17:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW17:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW17:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW17:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW17:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW17:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW17:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW17:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW17:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW17:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW17:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW17:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW17:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW17:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW17:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW17:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW17:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW17:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW17:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw17")
}

record(stringin, "ACSW:UNDH:NW17:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW17:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW17:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw17")
  field(DOL, "ACSW:UNDH:NW17:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW17:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(bo, "ACSW:UNDH:NW17:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(stringin, "ACSW:UNDH:NW17:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW17:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW17:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW17:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW17:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW17:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW17:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW17:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW17:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW17:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW17:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw17")
}

record(stringin, "ACSW:UNDH:NW17:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW17:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW17:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw17")
  field(DOL, "ACSW:UNDH:NW17:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW17:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(bo, "ACSW:UNDH:NW17:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(stringin, "ACSW:UNDH:NW17:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW17:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW17:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW17:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW17:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW17:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW17:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW17:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW17:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW17:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW17:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw17")
}

record(stringin, "ACSW:UNDH:NW17:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW17:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW17:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw17")
  field(DOL, "ACSW:UNDH:NW17:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW17:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(bo, "ACSW:UNDH:NW17:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(stringin, "ACSW:UNDH:NW17:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW17:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW17:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW17:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW17:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW17:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW17:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW17:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW17:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW17:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW17:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw17")
}

record(stringin, "ACSW:UNDH:NW17:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW17:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW17:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw17")
  field(DOL, "ACSW:UNDH:NW17:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW17:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(bo, "ACSW:UNDH:NW17:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(stringin, "ACSW:UNDH:NW17:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW17:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW17:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW17:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW17:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW17:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW17:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW17:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW17:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW17:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW17:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw17")
}

record(stringin, "ACSW:UNDH:NW17:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW17:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW17:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw17")
  field(DOL, "ACSW:UNDH:NW17:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW17:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(bo, "ACSW:UNDH:NW17:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(stringin, "ACSW:UNDH:NW17:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW17:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW17:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW17:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW17:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW17:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW17:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW17:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW17:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW17:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW17:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw17")
}

record(stringin, "ACSW:UNDH:NW17:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW17:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW17:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw17")
  field(DOL, "ACSW:UNDH:NW17:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW17:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(bo, "ACSW:UNDH:NW17:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(stringin, "ACSW:UNDH:NW17:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW17:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW17:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW17:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW17:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW17:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW17:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW17:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW17:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW17:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW17:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw17")
}

record(stringin, "ACSW:UNDH:NW17:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW17:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW17:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw17")
  field(DOL, "ACSW:UNDH:NW17:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW17:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(bo, "ACSW:UNDH:NW17:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(stringin, "ACSW:UNDH:NW17:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW17:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW17:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW17:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW17:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW17:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW17:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW17:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW17:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW17:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW17:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw17")
}

record(bo, "ACSW:UNDH:NW17:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw17")
}

record(stringin, "ACSW:UNDH:NW17:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW17:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW17:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw17")
  field(DOL, "ACSW:UNDH:NW17:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW17:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(bo, "ACSW:UNDH:NW17:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw17")
  field(FLNK, "ACSW:UNDH:NW17:GETINIT")
}

record(stringin, "ACSW:UNDH:NW17:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW17:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW17:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW17:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW17:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW17:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW17:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW17:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW18:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW18) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINFO")
}

record(stringin, "ACSW:UNDH:NW18:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW18) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(stringin, "ACSW:UNDH:NW18:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW18:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW18:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW18:SITEID")
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW18:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW18:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW18) acsw-undh-nw18")
}

record(stringin, "ACSW:UNDH:NW18:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW18) acsw-undh-nw18")
}

record(ai, "ACSW:UNDH:NW18:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW18:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-18H")
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW18:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw18")
}

record(calcout, "ACSW:UNDH:NW18:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW18:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW18:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW18:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW18:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW18:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW18:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW18:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW18:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW18:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW18:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW18:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW18:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW18:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW18:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW18:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW18:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW18:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW18:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW18:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW18:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW18:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW18:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW18:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW18:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW18:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw18")
}

record(stringin, "ACSW:UNDH:NW18:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW18:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW18:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw18")
  field(DOL, "ACSW:UNDH:NW18:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW18:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(bo, "ACSW:UNDH:NW18:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(stringin, "ACSW:UNDH:NW18:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW18:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW18:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW18:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW18:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW18:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW18:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW18:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW18:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW18:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW18:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw18")
}

record(stringin, "ACSW:UNDH:NW18:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW18:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW18:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw18")
  field(DOL, "ACSW:UNDH:NW18:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW18:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(bo, "ACSW:UNDH:NW18:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(stringin, "ACSW:UNDH:NW18:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW18:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW18:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW18:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW18:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW18:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW18:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW18:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW18:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW18:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW18:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw18")
}

record(stringin, "ACSW:UNDH:NW18:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW18:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW18:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw18")
  field(DOL, "ACSW:UNDH:NW18:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW18:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(bo, "ACSW:UNDH:NW18:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(stringin, "ACSW:UNDH:NW18:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW18:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW18:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW18:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW18:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW18:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW18:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW18:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW18:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW18:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW18:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw18")
}

record(stringin, "ACSW:UNDH:NW18:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW18:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW18:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw18")
  field(DOL, "ACSW:UNDH:NW18:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW18:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(bo, "ACSW:UNDH:NW18:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(stringin, "ACSW:UNDH:NW18:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW18:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW18:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW18:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW18:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW18:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW18:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW18:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW18:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW18:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW18:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw18")
}

record(stringin, "ACSW:UNDH:NW18:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW18:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW18:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw18")
  field(DOL, "ACSW:UNDH:NW18:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW18:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(bo, "ACSW:UNDH:NW18:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(stringin, "ACSW:UNDH:NW18:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW18:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW18:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW18:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW18:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW18:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW18:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW18:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW18:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW18:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW18:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw18")
}

record(stringin, "ACSW:UNDH:NW18:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW18:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW18:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw18")
  field(DOL, "ACSW:UNDH:NW18:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW18:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(bo, "ACSW:UNDH:NW18:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(stringin, "ACSW:UNDH:NW18:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW18:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW18:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW18:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW18:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW18:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW18:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW18:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW18:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW18:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW18:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw18")
}

record(stringin, "ACSW:UNDH:NW18:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW18:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW18:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw18")
  field(DOL, "ACSW:UNDH:NW18:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW18:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(bo, "ACSW:UNDH:NW18:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(stringin, "ACSW:UNDH:NW18:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW18:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW18:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW18:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW18:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW18:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW18:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW18:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW18:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW18:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW18:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw18")
}

record(bo, "ACSW:UNDH:NW18:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw18")
}

record(stringin, "ACSW:UNDH:NW18:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW18:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW18:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw18")
  field(DOL, "ACSW:UNDH:NW18:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW18:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(bo, "ACSW:UNDH:NW18:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw18")
  field(FLNK, "ACSW:UNDH:NW18:GETINIT")
}

record(stringin, "ACSW:UNDH:NW18:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW18:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW18:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW18:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW18:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW18:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW18:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW18:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW19:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW19) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINFO")
}

record(stringin, "ACSW:UNDH:NW19:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW19) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(stringin, "ACSW:UNDH:NW19:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW19:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW19:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW19:SITEID")
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW19:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW19:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW19) acsw-undh-nw19")
}

record(stringin, "ACSW:UNDH:NW19:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW19) acsw-undh-nw19")
}

record(ai, "ACSW:UNDH:NW19:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW19:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-19H")
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW19:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw19")
}

record(calcout, "ACSW:UNDH:NW19:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW19:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW19:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW19:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW19:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW19:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW19:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW19:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW19:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW19:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW19:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW19:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW19:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW19:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW19:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW19:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW19:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW19:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW19:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW19:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW19:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW19:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW19:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW19:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW19:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW19:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw19")
}

record(stringin, "ACSW:UNDH:NW19:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW19:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW19:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw19")
  field(DOL, "ACSW:UNDH:NW19:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW19:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(bo, "ACSW:UNDH:NW19:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(stringin, "ACSW:UNDH:NW19:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW19:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW19:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW19:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW19:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW19:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW19:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW19:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW19:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW19:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW19:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw19")
}

record(stringin, "ACSW:UNDH:NW19:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW19:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW19:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw19")
  field(DOL, "ACSW:UNDH:NW19:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW19:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(bo, "ACSW:UNDH:NW19:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(stringin, "ACSW:UNDH:NW19:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW19:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW19:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW19:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW19:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW19:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW19:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW19:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW19:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW19:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW19:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw19")
}

record(stringin, "ACSW:UNDH:NW19:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW19:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW19:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw19")
  field(DOL, "ACSW:UNDH:NW19:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW19:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(bo, "ACSW:UNDH:NW19:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(stringin, "ACSW:UNDH:NW19:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW19:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW19:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW19:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW19:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW19:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW19:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW19:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW19:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW19:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW19:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw19")
}

record(stringin, "ACSW:UNDH:NW19:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW19:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW19:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw19")
  field(DOL, "ACSW:UNDH:NW19:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW19:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(bo, "ACSW:UNDH:NW19:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(stringin, "ACSW:UNDH:NW19:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW19:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW19:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW19:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW19:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW19:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW19:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW19:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW19:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW19:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW19:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw19")
}

record(stringin, "ACSW:UNDH:NW19:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW19:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW19:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw19")
  field(DOL, "ACSW:UNDH:NW19:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW19:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(bo, "ACSW:UNDH:NW19:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(stringin, "ACSW:UNDH:NW19:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW19:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW19:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW19:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW19:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW19:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW19:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW19:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW19:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW19:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW19:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw19")
}

record(stringin, "ACSW:UNDH:NW19:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW19:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW19:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw19")
  field(DOL, "ACSW:UNDH:NW19:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW19:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(bo, "ACSW:UNDH:NW19:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(stringin, "ACSW:UNDH:NW19:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW19:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW19:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW19:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW19:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW19:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW19:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW19:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW19:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW19:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW19:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw19")
}

record(stringin, "ACSW:UNDH:NW19:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW19:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW19:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw19")
  field(DOL, "ACSW:UNDH:NW19:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW19:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(bo, "ACSW:UNDH:NW19:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(stringin, "ACSW:UNDH:NW19:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW19:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW19:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW19:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW19:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW19:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW19:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW19:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW19:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW19:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW19:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw19")
}

record(bo, "ACSW:UNDH:NW19:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw19")
}

record(stringin, "ACSW:UNDH:NW19:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW19:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW19:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw19")
  field(DOL, "ACSW:UNDH:NW19:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW19:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(bo, "ACSW:UNDH:NW19:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw19")
  field(FLNK, "ACSW:UNDH:NW19:GETINIT")
}

record(stringin, "ACSW:UNDH:NW19:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW19:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW19:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW19:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW19:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW19:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW19:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW19:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW20:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW20) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINFO")
}

record(stringin, "ACSW:UNDH:NW20:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW20) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(stringin, "ACSW:UNDH:NW20:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW20:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW20:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW20:SITEID")
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW20:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW20:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW20) acsw-undh-nw20")
}

record(stringin, "ACSW:UNDH:NW20:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW20) acsw-undh-nw20")
}

record(ai, "ACSW:UNDH:NW20:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW20:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-20H")
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW20:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw20")
}

record(calcout, "ACSW:UNDH:NW20:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW20:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW20:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW20:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW20:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW20:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW20:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW20:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW20:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW20:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW20:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW20:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW20:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW20:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW20:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW20:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW20:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW20:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW20:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW20:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW20:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW20:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW20:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW20:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW20:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW20:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw20")
}

record(stringin, "ACSW:UNDH:NW20:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW20:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW20:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw20")
  field(DOL, "ACSW:UNDH:NW20:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW20:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(bo, "ACSW:UNDH:NW20:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(stringin, "ACSW:UNDH:NW20:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW20:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW20:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW20:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW20:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW20:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW20:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW20:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW20:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW20:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW20:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw20")
}

record(stringin, "ACSW:UNDH:NW20:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW20:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW20:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw20")
  field(DOL, "ACSW:UNDH:NW20:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW20:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(bo, "ACSW:UNDH:NW20:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(stringin, "ACSW:UNDH:NW20:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW20:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW20:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW20:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW20:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW20:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW20:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW20:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW20:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW20:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW20:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw20")
}

record(stringin, "ACSW:UNDH:NW20:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW20:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW20:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw20")
  field(DOL, "ACSW:UNDH:NW20:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW20:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(bo, "ACSW:UNDH:NW20:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(stringin, "ACSW:UNDH:NW20:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW20:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW20:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW20:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW20:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW20:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW20:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW20:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW20:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW20:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW20:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw20")
}

record(stringin, "ACSW:UNDH:NW20:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW20:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW20:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw20")
  field(DOL, "ACSW:UNDH:NW20:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW20:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(bo, "ACSW:UNDH:NW20:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(stringin, "ACSW:UNDH:NW20:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW20:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW20:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW20:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW20:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW20:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW20:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW20:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW20:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW20:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW20:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw20")
}

record(stringin, "ACSW:UNDH:NW20:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW20:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW20:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw20")
  field(DOL, "ACSW:UNDH:NW20:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW20:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(bo, "ACSW:UNDH:NW20:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(stringin, "ACSW:UNDH:NW20:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW20:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW20:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW20:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW20:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW20:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW20:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW20:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW20:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW20:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW20:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw20")
}

record(stringin, "ACSW:UNDH:NW20:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW20:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW20:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw20")
  field(DOL, "ACSW:UNDH:NW20:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW20:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(bo, "ACSW:UNDH:NW20:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(stringin, "ACSW:UNDH:NW20:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW20:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW20:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW20:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW20:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW20:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW20:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW20:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW20:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW20:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW20:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw20")
}

record(stringin, "ACSW:UNDH:NW20:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW20:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW20:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw20")
  field(DOL, "ACSW:UNDH:NW20:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW20:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(bo, "ACSW:UNDH:NW20:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(stringin, "ACSW:UNDH:NW20:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW20:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW20:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW20:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW20:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW20:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW20:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW20:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW20:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW20:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW20:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw20")
}

record(bo, "ACSW:UNDH:NW20:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw20")
}

record(stringin, "ACSW:UNDH:NW20:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW20:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW20:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw20")
  field(DOL, "ACSW:UNDH:NW20:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW20:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(bo, "ACSW:UNDH:NW20:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw20")
  field(FLNK, "ACSW:UNDH:NW20:GETINIT")
}

record(stringin, "ACSW:UNDH:NW20:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW20:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW20:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW20:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW20:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW20:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW20:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW20:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW21:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW21) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINFO")
}

record(stringin, "ACSW:UNDH:NW21:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW21) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(stringin, "ACSW:UNDH:NW21:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW21:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW21:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW21:SITEID")
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW21:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW21:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW21) acsw-undh-nw21")
}

record(stringin, "ACSW:UNDH:NW21:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW21) acsw-undh-nw21")
}

record(ai, "ACSW:UNDH:NW21:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW21:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-21H")
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW21:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw21")
}

record(calcout, "ACSW:UNDH:NW21:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW21:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW21:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW21:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW21:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW21:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW21:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW21:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW21:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW21:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW21:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW21:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW21:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW21:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW21:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW21:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW21:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW21:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW21:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW21:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW21:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW21:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW21:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW21:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW21:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW21:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw21")
}

record(stringin, "ACSW:UNDH:NW21:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW21:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW21:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw21")
  field(DOL, "ACSW:UNDH:NW21:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW21:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(bo, "ACSW:UNDH:NW21:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(stringin, "ACSW:UNDH:NW21:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW21:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW21:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW21:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW21:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW21:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW21:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW21:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW21:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW21:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW21:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw21")
}

record(stringin, "ACSW:UNDH:NW21:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW21:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW21:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw21")
  field(DOL, "ACSW:UNDH:NW21:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW21:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(bo, "ACSW:UNDH:NW21:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(stringin, "ACSW:UNDH:NW21:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW21:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW21:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW21:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW21:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW21:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW21:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW21:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW21:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW21:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW21:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw21")
}

record(stringin, "ACSW:UNDH:NW21:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW21:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW21:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw21")
  field(DOL, "ACSW:UNDH:NW21:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW21:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(bo, "ACSW:UNDH:NW21:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(stringin, "ACSW:UNDH:NW21:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW21:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW21:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW21:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW21:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW21:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW21:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW21:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW21:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW21:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW21:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw21")
}

record(stringin, "ACSW:UNDH:NW21:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW21:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW21:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw21")
  field(DOL, "ACSW:UNDH:NW21:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW21:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(bo, "ACSW:UNDH:NW21:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(stringin, "ACSW:UNDH:NW21:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW21:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW21:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW21:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW21:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW21:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW21:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW21:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW21:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW21:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW21:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw21")
}

record(stringin, "ACSW:UNDH:NW21:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW21:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW21:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw21")
  field(DOL, "ACSW:UNDH:NW21:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW21:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(bo, "ACSW:UNDH:NW21:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(stringin, "ACSW:UNDH:NW21:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW21:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW21:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW21:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW21:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW21:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW21:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW21:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW21:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW21:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW21:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw21")
}

record(stringin, "ACSW:UNDH:NW21:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW21:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW21:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw21")
  field(DOL, "ACSW:UNDH:NW21:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW21:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(bo, "ACSW:UNDH:NW21:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(stringin, "ACSW:UNDH:NW21:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW21:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW21:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW21:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW21:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW21:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW21:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW21:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW21:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW21:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW21:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw21")
}

record(stringin, "ACSW:UNDH:NW21:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW21:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW21:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw21")
  field(DOL, "ACSW:UNDH:NW21:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW21:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(bo, "ACSW:UNDH:NW21:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(stringin, "ACSW:UNDH:NW21:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW21:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW21:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW21:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW21:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW21:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW21:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW21:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW21:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW21:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW21:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw21")
}

record(bo, "ACSW:UNDH:NW21:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw21")
}

record(stringin, "ACSW:UNDH:NW21:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW21:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW21:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw21")
  field(DOL, "ACSW:UNDH:NW21:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW21:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(bo, "ACSW:UNDH:NW21:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw21")
  field(FLNK, "ACSW:UNDH:NW21:GETINIT")
}

record(stringin, "ACSW:UNDH:NW21:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW21:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW21:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW21:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW21:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW21:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW21:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW21:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW22:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW22) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINFO")
}

record(stringin, "ACSW:UNDH:NW22:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW22) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(stringin, "ACSW:UNDH:NW22:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW22:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW22:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW22:SITEID")
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW22:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW22:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW22) acsw-undh-nw22")
}

record(stringin, "ACSW:UNDH:NW22:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW22) acsw-undh-nw22")
}

record(ai, "ACSW:UNDH:NW22:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW22:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-22H")
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW22:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw22")
}

record(calcout, "ACSW:UNDH:NW22:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW22:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW22:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW22:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW22:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW22:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW22:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW22:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW22:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW22:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW22:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW22:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW22:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW22:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW22:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW22:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW22:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW22:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW22:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW22:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW22:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW22:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW22:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW22:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW22:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW22:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw22")
}

record(stringin, "ACSW:UNDH:NW22:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW22:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW22:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw22")
  field(DOL, "ACSW:UNDH:NW22:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW22:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(bo, "ACSW:UNDH:NW22:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(stringin, "ACSW:UNDH:NW22:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW22:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW22:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW22:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW22:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW22:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW22:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW22:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW22:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW22:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW22:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw22")
}

record(stringin, "ACSW:UNDH:NW22:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW22:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW22:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw22")
  field(DOL, "ACSW:UNDH:NW22:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW22:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(bo, "ACSW:UNDH:NW22:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(stringin, "ACSW:UNDH:NW22:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW22:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW22:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW22:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW22:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW22:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW22:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW22:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW22:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW22:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW22:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw22")
}

record(stringin, "ACSW:UNDH:NW22:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW22:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW22:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw22")
  field(DOL, "ACSW:UNDH:NW22:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW22:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(bo, "ACSW:UNDH:NW22:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(stringin, "ACSW:UNDH:NW22:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW22:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW22:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW22:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW22:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW22:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW22:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW22:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW22:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW22:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW22:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw22")
}

record(stringin, "ACSW:UNDH:NW22:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW22:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW22:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw22")
  field(DOL, "ACSW:UNDH:NW22:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW22:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(bo, "ACSW:UNDH:NW22:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(stringin, "ACSW:UNDH:NW22:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW22:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW22:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW22:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW22:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW22:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW22:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW22:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW22:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW22:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW22:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw22")
}

record(stringin, "ACSW:UNDH:NW22:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW22:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW22:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw22")
  field(DOL, "ACSW:UNDH:NW22:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW22:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(bo, "ACSW:UNDH:NW22:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(stringin, "ACSW:UNDH:NW22:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW22:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW22:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW22:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW22:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW22:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW22:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW22:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW22:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW22:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW22:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw22")
}

record(stringin, "ACSW:UNDH:NW22:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW22:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW22:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw22")
  field(DOL, "ACSW:UNDH:NW22:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW22:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(bo, "ACSW:UNDH:NW22:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(stringin, "ACSW:UNDH:NW22:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW22:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW22:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW22:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW22:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW22:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW22:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW22:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW22:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW22:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW22:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw22")
}

record(stringin, "ACSW:UNDH:NW22:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW22:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW22:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw22")
  field(DOL, "ACSW:UNDH:NW22:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW22:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(bo, "ACSW:UNDH:NW22:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(stringin, "ACSW:UNDH:NW22:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW22:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW22:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW22:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW22:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW22:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW22:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW22:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW22:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW22:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW22:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw22")
}

record(bo, "ACSW:UNDH:NW22:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw22")
}

record(stringin, "ACSW:UNDH:NW22:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW22:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW22:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw22")
  field(DOL, "ACSW:UNDH:NW22:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW22:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(bo, "ACSW:UNDH:NW22:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw22")
  field(FLNK, "ACSW:UNDH:NW22:GETINIT")
}

record(stringin, "ACSW:UNDH:NW22:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW22:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW22:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW22:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW22:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW22:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW22:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW22:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW23:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW23) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINFO")
}

record(stringin, "ACSW:UNDH:NW23:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW23) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(stringin, "ACSW:UNDH:NW23:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW23:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW23:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW23:SITEID")
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW23:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW23:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW23) acsw-undh-nw23")
}

record(stringin, "ACSW:UNDH:NW23:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW23) acsw-undh-nw23")
}

record(ai, "ACSW:UNDH:NW23:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW23:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-23H")
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW23:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw23")
}

record(calcout, "ACSW:UNDH:NW23:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW23:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW23:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW23:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW23:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW23:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW23:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW23:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW23:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW23:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW23:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW23:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW23:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW23:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW23:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW23:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW23:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW23:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW23:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW23:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW23:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW23:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW23:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW23:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW23:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW23:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw23")
}

record(stringin, "ACSW:UNDH:NW23:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW23:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW23:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw23")
  field(DOL, "ACSW:UNDH:NW23:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW23:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(bo, "ACSW:UNDH:NW23:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(stringin, "ACSW:UNDH:NW23:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW23:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW23:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW23:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW23:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW23:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW23:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW23:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW23:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW23:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW23:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw23")
}

record(stringin, "ACSW:UNDH:NW23:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW23:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW23:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw23")
  field(DOL, "ACSW:UNDH:NW23:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW23:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(bo, "ACSW:UNDH:NW23:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(stringin, "ACSW:UNDH:NW23:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW23:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW23:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW23:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW23:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW23:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW23:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW23:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW23:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW23:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW23:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw23")
}

record(stringin, "ACSW:UNDH:NW23:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW23:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW23:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw23")
  field(DOL, "ACSW:UNDH:NW23:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW23:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(bo, "ACSW:UNDH:NW23:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(stringin, "ACSW:UNDH:NW23:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW23:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW23:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW23:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW23:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW23:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW23:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW23:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW23:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW23:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW23:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw23")
}

record(stringin, "ACSW:UNDH:NW23:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW23:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW23:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw23")
  field(DOL, "ACSW:UNDH:NW23:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW23:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(bo, "ACSW:UNDH:NW23:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(stringin, "ACSW:UNDH:NW23:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW23:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW23:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW23:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW23:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW23:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW23:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW23:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW23:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW23:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW23:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw23")
}

record(stringin, "ACSW:UNDH:NW23:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW23:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW23:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw23")
  field(DOL, "ACSW:UNDH:NW23:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW23:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(bo, "ACSW:UNDH:NW23:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(stringin, "ACSW:UNDH:NW23:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW23:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW23:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW23:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW23:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW23:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW23:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW23:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW23:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW23:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW23:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw23")
}

record(stringin, "ACSW:UNDH:NW23:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW23:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW23:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw23")
  field(DOL, "ACSW:UNDH:NW23:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW23:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(bo, "ACSW:UNDH:NW23:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(stringin, "ACSW:UNDH:NW23:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW23:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW23:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW23:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW23:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW23:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW23:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW23:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW23:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW23:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW23:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw23")
}

record(stringin, "ACSW:UNDH:NW23:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW23:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW23:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw23")
  field(DOL, "ACSW:UNDH:NW23:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW23:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(bo, "ACSW:UNDH:NW23:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(stringin, "ACSW:UNDH:NW23:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW23:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW23:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW23:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW23:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW23:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW23:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW23:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW23:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW23:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW23:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw23")
}

record(bo, "ACSW:UNDH:NW23:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw23")
}

record(stringin, "ACSW:UNDH:NW23:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW23:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW23:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw23")
  field(DOL, "ACSW:UNDH:NW23:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW23:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(bo, "ACSW:UNDH:NW23:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw23")
  field(FLNK, "ACSW:UNDH:NW23:GETINIT")
}

record(stringin, "ACSW:UNDH:NW23:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW23:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW23:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW23:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW23:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW23:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW23:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW23:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW24:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW24) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINFO")
}

record(stringin, "ACSW:UNDH:NW24:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW24) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(stringin, "ACSW:UNDH:NW24:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW24:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW24:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW24:SITEID")
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW24:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW24:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW24) acsw-undh-nw24")
}

record(stringin, "ACSW:UNDH:NW24:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW24) acsw-undh-nw24")
}

record(ai, "ACSW:UNDH:NW24:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW24:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-24H")
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW24:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw24")
}

record(calcout, "ACSW:UNDH:NW24:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW24:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW24:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW24:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW24:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW24:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW24:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW24:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW24:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW24:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW24:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW24:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW24:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW24:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW24:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW24:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW24:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW24:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW24:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW24:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW24:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW24:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW24:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW24:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW24:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW24:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw24")
}

record(stringin, "ACSW:UNDH:NW24:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW24:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW24:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw24")
  field(DOL, "ACSW:UNDH:NW24:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW24:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(bo, "ACSW:UNDH:NW24:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(stringin, "ACSW:UNDH:NW24:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW24:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW24:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW24:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW24:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW24:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW24:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW24:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW24:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW24:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW24:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw24")
}

record(stringin, "ACSW:UNDH:NW24:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW24:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW24:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw24")
  field(DOL, "ACSW:UNDH:NW24:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW24:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(bo, "ACSW:UNDH:NW24:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(stringin, "ACSW:UNDH:NW24:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW24:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW24:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW24:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW24:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW24:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW24:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW24:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW24:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW24:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW24:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw24")
}

record(stringin, "ACSW:UNDH:NW24:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW24:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW24:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw24")
  field(DOL, "ACSW:UNDH:NW24:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW24:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(bo, "ACSW:UNDH:NW24:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(stringin, "ACSW:UNDH:NW24:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW24:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW24:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW24:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW24:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW24:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW24:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW24:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW24:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW24:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW24:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw24")
}

record(stringin, "ACSW:UNDH:NW24:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW24:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW24:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw24")
  field(DOL, "ACSW:UNDH:NW24:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW24:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(bo, "ACSW:UNDH:NW24:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(stringin, "ACSW:UNDH:NW24:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW24:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW24:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW24:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW24:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW24:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW24:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW24:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW24:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW24:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW24:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw24")
}

record(stringin, "ACSW:UNDH:NW24:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW24:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW24:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw24")
  field(DOL, "ACSW:UNDH:NW24:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW24:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(bo, "ACSW:UNDH:NW24:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(stringin, "ACSW:UNDH:NW24:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW24:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW24:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW24:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW24:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW24:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW24:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW24:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW24:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW24:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW24:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw24")
}

record(stringin, "ACSW:UNDH:NW24:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW24:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW24:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw24")
  field(DOL, "ACSW:UNDH:NW24:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW24:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(bo, "ACSW:UNDH:NW24:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(stringin, "ACSW:UNDH:NW24:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW24:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW24:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW24:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW24:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW24:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW24:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW24:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW24:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW24:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW24:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw24")
}

record(stringin, "ACSW:UNDH:NW24:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW24:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW24:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw24")
  field(DOL, "ACSW:UNDH:NW24:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW24:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(bo, "ACSW:UNDH:NW24:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(stringin, "ACSW:UNDH:NW24:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW24:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW24:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW24:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW24:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW24:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW24:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW24:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW24:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW24:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW24:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw24")
}

record(bo, "ACSW:UNDH:NW24:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw24")
}

record(stringin, "ACSW:UNDH:NW24:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW24:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW24:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw24")
  field(DOL, "ACSW:UNDH:NW24:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW24:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(bo, "ACSW:UNDH:NW24:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw24")
  field(FLNK, "ACSW:UNDH:NW24:GETINIT")
}

record(stringin, "ACSW:UNDH:NW24:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW24:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW24:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW24:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW24:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW24:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW24:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW24:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW25:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW25) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINFO")
}

record(stringin, "ACSW:UNDH:NW25:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW25) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(stringin, "ACSW:UNDH:NW25:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW25:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW25:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW25:SITEID")
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW25:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW25:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW25) acsw-undh-nw25")
}

record(stringin, "ACSW:UNDH:NW25:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW25) acsw-undh-nw25")
}

record(ai, "ACSW:UNDH:NW25:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW25:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-25H")
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW25:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw25")
}

record(calcout, "ACSW:UNDH:NW25:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW25:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW25:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW25:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW25:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW25:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW25:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW25:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW25:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW25:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW25:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW25:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW25:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW25:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW25:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW25:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW25:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW25:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW25:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW25:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW25:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW25:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW25:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW25:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW25:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW25:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw25")
}

record(stringin, "ACSW:UNDH:NW25:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW25:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW25:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw25")
  field(DOL, "ACSW:UNDH:NW25:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW25:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(bo, "ACSW:UNDH:NW25:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(stringin, "ACSW:UNDH:NW25:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW25:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW25:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW25:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW25:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW25:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW25:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW25:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW25:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW25:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW25:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw25")
}

record(stringin, "ACSW:UNDH:NW25:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW25:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW25:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw25")
  field(DOL, "ACSW:UNDH:NW25:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW25:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(bo, "ACSW:UNDH:NW25:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(stringin, "ACSW:UNDH:NW25:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW25:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW25:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW25:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW25:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW25:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW25:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW25:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW25:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW25:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW25:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw25")
}

record(stringin, "ACSW:UNDH:NW25:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW25:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW25:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw25")
  field(DOL, "ACSW:UNDH:NW25:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW25:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(bo, "ACSW:UNDH:NW25:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(stringin, "ACSW:UNDH:NW25:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW25:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW25:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW25:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW25:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW25:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW25:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW25:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW25:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW25:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW25:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw25")
}

record(stringin, "ACSW:UNDH:NW25:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW25:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW25:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw25")
  field(DOL, "ACSW:UNDH:NW25:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW25:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(bo, "ACSW:UNDH:NW25:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(stringin, "ACSW:UNDH:NW25:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW25:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW25:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW25:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW25:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW25:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW25:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW25:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW25:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW25:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW25:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw25")
}

record(stringin, "ACSW:UNDH:NW25:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW25:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW25:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw25")
  field(DOL, "ACSW:UNDH:NW25:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW25:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(bo, "ACSW:UNDH:NW25:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(stringin, "ACSW:UNDH:NW25:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW25:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW25:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW25:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW25:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW25:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW25:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW25:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW25:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW25:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW25:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw25")
}

record(stringin, "ACSW:UNDH:NW25:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW25:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW25:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw25")
  field(DOL, "ACSW:UNDH:NW25:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW25:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(bo, "ACSW:UNDH:NW25:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(stringin, "ACSW:UNDH:NW25:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW25:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW25:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW25:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW25:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW25:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW25:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW25:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW25:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW25:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW25:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw25")
}

record(stringin, "ACSW:UNDH:NW25:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW25:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW25:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw25")
  field(DOL, "ACSW:UNDH:NW25:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW25:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(bo, "ACSW:UNDH:NW25:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(stringin, "ACSW:UNDH:NW25:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW25:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW25:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW25:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW25:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW25:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW25:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW25:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW25:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW25:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW25:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw25")
}

record(bo, "ACSW:UNDH:NW25:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw25")
}

record(stringin, "ACSW:UNDH:NW25:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW25:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW25:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw25")
  field(DOL, "ACSW:UNDH:NW25:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW25:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(bo, "ACSW:UNDH:NW25:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw25")
  field(FLNK, "ACSW:UNDH:NW25:GETINIT")
}

record(stringin, "ACSW:UNDH:NW25:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW25:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW25:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW25:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW25:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW25:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW25:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW25:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW26:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW26) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINFO")
}

record(stringin, "ACSW:UNDH:NW26:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW26) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(stringin, "ACSW:UNDH:NW26:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW26:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW26:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW26:SITEID")
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW26:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW26:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW26) acsw-undh-nw26")
}

record(stringin, "ACSW:UNDH:NW26:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW26) acsw-undh-nw26")
}

record(ai, "ACSW:UNDH:NW26:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW26:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-26H")
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW26:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw26")
}

record(calcout, "ACSW:UNDH:NW26:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW26:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW26:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW26:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW26:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW26:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW26:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW26:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW26:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW26:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW26:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW26:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW26:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW26:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW26:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW26:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW26:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW26:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW26:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW26:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW26:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW26:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW26:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW26:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW26:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW26:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw26")
}

record(stringin, "ACSW:UNDH:NW26:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW26:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW26:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw26")
  field(DOL, "ACSW:UNDH:NW26:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW26:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(bo, "ACSW:UNDH:NW26:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(stringin, "ACSW:UNDH:NW26:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW26:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW26:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW26:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW26:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW26:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW26:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW26:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW26:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW26:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW26:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw26")
}

record(stringin, "ACSW:UNDH:NW26:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW26:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW26:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw26")
  field(DOL, "ACSW:UNDH:NW26:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW26:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(bo, "ACSW:UNDH:NW26:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(stringin, "ACSW:UNDH:NW26:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW26:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW26:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW26:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW26:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW26:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW26:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW26:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW26:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW26:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW26:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw26")
}

record(stringin, "ACSW:UNDH:NW26:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW26:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW26:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw26")
  field(DOL, "ACSW:UNDH:NW26:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW26:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(bo, "ACSW:UNDH:NW26:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(stringin, "ACSW:UNDH:NW26:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW26:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW26:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW26:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW26:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW26:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW26:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW26:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW26:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW26:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW26:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw26")
}

record(stringin, "ACSW:UNDH:NW26:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW26:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW26:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw26")
  field(DOL, "ACSW:UNDH:NW26:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW26:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(bo, "ACSW:UNDH:NW26:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(stringin, "ACSW:UNDH:NW26:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW26:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW26:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW26:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW26:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW26:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW26:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW26:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW26:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW26:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW26:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw26")
}

record(stringin, "ACSW:UNDH:NW26:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW26:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW26:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw26")
  field(DOL, "ACSW:UNDH:NW26:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW26:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(bo, "ACSW:UNDH:NW26:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(stringin, "ACSW:UNDH:NW26:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW26:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW26:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW26:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW26:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW26:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW26:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW26:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW26:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW26:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW26:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw26")
}

record(stringin, "ACSW:UNDH:NW26:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW26:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW26:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw26")
  field(DOL, "ACSW:UNDH:NW26:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW26:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(bo, "ACSW:UNDH:NW26:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(stringin, "ACSW:UNDH:NW26:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW26:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW26:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW26:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW26:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW26:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW26:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW26:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW26:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW26:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW26:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw26")
}

record(stringin, "ACSW:UNDH:NW26:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW26:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW26:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw26")
  field(DOL, "ACSW:UNDH:NW26:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW26:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(bo, "ACSW:UNDH:NW26:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(stringin, "ACSW:UNDH:NW26:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW26:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW26:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW26:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW26:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW26:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW26:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW26:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW26:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW26:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW26:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw26")
}

record(bo, "ACSW:UNDH:NW26:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw26")
}

record(stringin, "ACSW:UNDH:NW26:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW26:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW26:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw26")
  field(DOL, "ACSW:UNDH:NW26:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW26:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(bo, "ACSW:UNDH:NW26:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw26")
  field(FLNK, "ACSW:UNDH:NW26:GETINIT")
}

record(stringin, "ACSW:UNDH:NW26:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW26:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW26:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW26:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW26:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW26:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW26:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW26:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW27:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW27) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINFO")
}

record(stringin, "ACSW:UNDH:NW27:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW27) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(stringin, "ACSW:UNDH:NW27:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW27:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW27:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW27:SITEID")
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW27:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW27:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW27) acsw-undh-nw27")
}

record(stringin, "ACSW:UNDH:NW27:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW27) acsw-undh-nw27")
}

record(ai, "ACSW:UNDH:NW27:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW27:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-27H")
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW27:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw27")
}

record(calcout, "ACSW:UNDH:NW27:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW27:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW27:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW27:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW27:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW27:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW27:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW27:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW27:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW27:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW27:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW27:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW27:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW27:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW27:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW27:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW27:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW27:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW27:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW27:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW27:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW27:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW27:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW27:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW27:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW27:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw27")
}

record(stringin, "ACSW:UNDH:NW27:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW27:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW27:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw27")
  field(DOL, "ACSW:UNDH:NW27:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW27:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(bo, "ACSW:UNDH:NW27:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(stringin, "ACSW:UNDH:NW27:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW27:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW27:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW27:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW27:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW27:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW27:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW27:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW27:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW27:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW27:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw27")
}

record(stringin, "ACSW:UNDH:NW27:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW27:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW27:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw27")
  field(DOL, "ACSW:UNDH:NW27:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW27:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(bo, "ACSW:UNDH:NW27:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(stringin, "ACSW:UNDH:NW27:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW27:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW27:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW27:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW27:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW27:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW27:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW27:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW27:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW27:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW27:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw27")
}

record(stringin, "ACSW:UNDH:NW27:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW27:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW27:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw27")
  field(DOL, "ACSW:UNDH:NW27:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW27:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(bo, "ACSW:UNDH:NW27:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(stringin, "ACSW:UNDH:NW27:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW27:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW27:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW27:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW27:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW27:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW27:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW27:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW27:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW27:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW27:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw27")
}

record(stringin, "ACSW:UNDH:NW27:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW27:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW27:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw27")
  field(DOL, "ACSW:UNDH:NW27:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW27:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(bo, "ACSW:UNDH:NW27:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(stringin, "ACSW:UNDH:NW27:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW27:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW27:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW27:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW27:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW27:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW27:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW27:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW27:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW27:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW27:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw27")
}

record(stringin, "ACSW:UNDH:NW27:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW27:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW27:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw27")
  field(DOL, "ACSW:UNDH:NW27:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW27:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(bo, "ACSW:UNDH:NW27:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(stringin, "ACSW:UNDH:NW27:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW27:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW27:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW27:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW27:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW27:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW27:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW27:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW27:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW27:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW27:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw27")
}

record(stringin, "ACSW:UNDH:NW27:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW27:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW27:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw27")
  field(DOL, "ACSW:UNDH:NW27:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW27:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(bo, "ACSW:UNDH:NW27:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(stringin, "ACSW:UNDH:NW27:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW27:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW27:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW27:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW27:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW27:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW27:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW27:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW27:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW27:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW27:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw27")
}

record(stringin, "ACSW:UNDH:NW27:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW27:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW27:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw27")
  field(DOL, "ACSW:UNDH:NW27:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW27:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(bo, "ACSW:UNDH:NW27:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(stringin, "ACSW:UNDH:NW27:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW27:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW27:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW27:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW27:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW27:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW27:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW27:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW27:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW27:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW27:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw27")
}

record(bo, "ACSW:UNDH:NW27:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw27")
}

record(stringin, "ACSW:UNDH:NW27:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW27:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW27:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw27")
  field(DOL, "ACSW:UNDH:NW27:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW27:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(bo, "ACSW:UNDH:NW27:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw27")
  field(FLNK, "ACSW:UNDH:NW27:GETINIT")
}

record(stringin, "ACSW:UNDH:NW27:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW27:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW27:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW27:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW27:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW27:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW27:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW27:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW28:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW28) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINFO")
}

record(stringin, "ACSW:UNDH:NW28:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW28) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(stringin, "ACSW:UNDH:NW28:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW28:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW28:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW28:SITEID")
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW28:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW28:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW28) acsw-undh-nw28")
}

record(stringin, "ACSW:UNDH:NW28:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW28) acsw-undh-nw28")
}

record(ai, "ACSW:UNDH:NW28:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW28:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-28H")
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW28:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw28")
}

record(calcout, "ACSW:UNDH:NW28:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW28:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW28:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW28:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW28:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW28:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW28:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW28:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW28:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW28:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW28:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW28:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW28:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW28:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW28:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW28:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW28:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW28:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW28:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW28:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW28:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW28:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW28:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW28:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW28:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW28:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw28")
}

record(stringin, "ACSW:UNDH:NW28:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW28:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW28:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw28")
  field(DOL, "ACSW:UNDH:NW28:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW28:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(bo, "ACSW:UNDH:NW28:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(stringin, "ACSW:UNDH:NW28:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW28:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW28:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW28:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW28:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW28:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW28:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW28:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW28:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW28:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW28:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw28")
}

record(stringin, "ACSW:UNDH:NW28:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW28:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW28:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw28")
  field(DOL, "ACSW:UNDH:NW28:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW28:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(bo, "ACSW:UNDH:NW28:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(stringin, "ACSW:UNDH:NW28:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW28:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW28:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW28:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW28:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW28:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW28:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW28:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW28:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW28:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW28:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw28")
}

record(stringin, "ACSW:UNDH:NW28:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW28:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW28:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw28")
  field(DOL, "ACSW:UNDH:NW28:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW28:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(bo, "ACSW:UNDH:NW28:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(stringin, "ACSW:UNDH:NW28:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW28:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW28:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW28:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW28:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW28:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW28:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW28:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW28:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW28:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW28:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw28")
}

record(stringin, "ACSW:UNDH:NW28:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW28:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW28:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw28")
  field(DOL, "ACSW:UNDH:NW28:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW28:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(bo, "ACSW:UNDH:NW28:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(stringin, "ACSW:UNDH:NW28:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW28:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW28:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW28:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW28:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW28:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW28:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW28:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW28:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW28:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW28:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw28")
}

record(stringin, "ACSW:UNDH:NW28:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW28:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW28:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw28")
  field(DOL, "ACSW:UNDH:NW28:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW28:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(bo, "ACSW:UNDH:NW28:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(stringin, "ACSW:UNDH:NW28:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW28:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW28:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW28:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW28:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW28:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW28:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW28:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW28:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW28:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW28:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw28")
}

record(stringin, "ACSW:UNDH:NW28:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW28:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW28:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw28")
  field(DOL, "ACSW:UNDH:NW28:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW28:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(bo, "ACSW:UNDH:NW28:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(stringin, "ACSW:UNDH:NW28:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW28:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW28:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW28:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW28:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW28:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW28:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW28:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW28:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW28:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW28:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw28")
}

record(stringin, "ACSW:UNDH:NW28:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW28:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW28:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw28")
  field(DOL, "ACSW:UNDH:NW28:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW28:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(bo, "ACSW:UNDH:NW28:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(stringin, "ACSW:UNDH:NW28:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW28:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW28:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW28:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW28:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW28:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW28:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW28:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW28:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW28:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW28:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw28")
}

record(bo, "ACSW:UNDH:NW28:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw28")
}

record(stringin, "ACSW:UNDH:NW28:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW28:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW28:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw28")
  field(DOL, "ACSW:UNDH:NW28:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW28:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(bo, "ACSW:UNDH:NW28:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw28")
  field(FLNK, "ACSW:UNDH:NW28:GETINIT")
}

record(stringin, "ACSW:UNDH:NW28:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW28:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW28:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW28:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW28:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW28:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW28:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW28:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW29:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW29) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINFO")
}

record(stringin, "ACSW:UNDH:NW29:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW29) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(stringin, "ACSW:UNDH:NW29:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW29:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW29:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW29:SITEID")
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW29:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW29:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW29) acsw-undh-nw29")
}

record(stringin, "ACSW:UNDH:NW29:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW29) acsw-undh-nw29")
}

record(ai, "ACSW:UNDH:NW29:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW29:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-29H")
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW29:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw29")
}

record(calcout, "ACSW:UNDH:NW29:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW29:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW29:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW29:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW29:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW29:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW29:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW29:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW29:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW29:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW29:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW29:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW29:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW29:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW29:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW29:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW29:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW29:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW29:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW29:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW29:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW29:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW29:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW29:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW29:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW29:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw29")
}

record(stringin, "ACSW:UNDH:NW29:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW29:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW29:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw29")
  field(DOL, "ACSW:UNDH:NW29:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW29:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(bo, "ACSW:UNDH:NW29:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(stringin, "ACSW:UNDH:NW29:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW29:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW29:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW29:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW29:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW29:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW29:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW29:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW29:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW29:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW29:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw29")
}

record(stringin, "ACSW:UNDH:NW29:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW29:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW29:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw29")
  field(DOL, "ACSW:UNDH:NW29:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW29:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(bo, "ACSW:UNDH:NW29:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(stringin, "ACSW:UNDH:NW29:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW29:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW29:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW29:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW29:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW29:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW29:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW29:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW29:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW29:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW29:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw29")
}

record(stringin, "ACSW:UNDH:NW29:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW29:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW29:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw29")
  field(DOL, "ACSW:UNDH:NW29:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW29:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(bo, "ACSW:UNDH:NW29:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(stringin, "ACSW:UNDH:NW29:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW29:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW29:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW29:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW29:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW29:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW29:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW29:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW29:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW29:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW29:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw29")
}

record(stringin, "ACSW:UNDH:NW29:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW29:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW29:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw29")
  field(DOL, "ACSW:UNDH:NW29:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW29:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(bo, "ACSW:UNDH:NW29:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(stringin, "ACSW:UNDH:NW29:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW29:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW29:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW29:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW29:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW29:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW29:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW29:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW29:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW29:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW29:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw29")
}

record(stringin, "ACSW:UNDH:NW29:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW29:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW29:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw29")
  field(DOL, "ACSW:UNDH:NW29:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW29:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(bo, "ACSW:UNDH:NW29:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(stringin, "ACSW:UNDH:NW29:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW29:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW29:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW29:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW29:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW29:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW29:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW29:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW29:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW29:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW29:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw29")
}

record(stringin, "ACSW:UNDH:NW29:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW29:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW29:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw29")
  field(DOL, "ACSW:UNDH:NW29:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW29:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(bo, "ACSW:UNDH:NW29:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(stringin, "ACSW:UNDH:NW29:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW29:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW29:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW29:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW29:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW29:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW29:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW29:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW29:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW29:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW29:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw29")
}

record(stringin, "ACSW:UNDH:NW29:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW29:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW29:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw29")
  field(DOL, "ACSW:UNDH:NW29:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW29:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(bo, "ACSW:UNDH:NW29:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(stringin, "ACSW:UNDH:NW29:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW29:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW29:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW29:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW29:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW29:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW29:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW29:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW29:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW29:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW29:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw29")
}

record(bo, "ACSW:UNDH:NW29:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw29")
}

record(stringin, "ACSW:UNDH:NW29:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW29:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW29:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw29")
  field(DOL, "ACSW:UNDH:NW29:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW29:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(bo, "ACSW:UNDH:NW29:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw29")
  field(FLNK, "ACSW:UNDH:NW29:GETINIT")
}

record(stringin, "ACSW:UNDH:NW29:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW29:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW29:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW29:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW29:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW29:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW29:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW29:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW30:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW30) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINFO")
}

record(stringin, "ACSW:UNDH:NW30:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW30) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(stringin, "ACSW:UNDH:NW30:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW30:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW30:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW30:SITEID")
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW30:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW30:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW30) acsw-undh-nw30")
}

record(stringin, "ACSW:UNDH:NW30:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW30) acsw-undh-nw30")
}

record(ai, "ACSW:UNDH:NW30:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW30:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-30H")
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW30:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw30")
}

record(calcout, "ACSW:UNDH:NW30:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW30:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW30:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW30:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW30:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW30:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW30:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW30:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW30:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW30:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW30:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW30:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW30:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW30:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW30:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW30:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW30:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW30:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW30:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW30:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW30:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW30:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW30:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW30:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW30:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW30:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw30")
}

record(stringin, "ACSW:UNDH:NW30:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW30:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW30:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw30")
  field(DOL, "ACSW:UNDH:NW30:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW30:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(bo, "ACSW:UNDH:NW30:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(stringin, "ACSW:UNDH:NW30:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW30:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW30:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW30:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW30:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW30:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW30:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW30:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW30:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW30:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW30:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw30")
}

record(stringin, "ACSW:UNDH:NW30:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW30:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW30:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw30")
  field(DOL, "ACSW:UNDH:NW30:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW30:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(bo, "ACSW:UNDH:NW30:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(stringin, "ACSW:UNDH:NW30:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW30:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW30:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW30:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW30:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW30:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW30:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW30:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW30:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW30:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW30:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw30")
}

record(stringin, "ACSW:UNDH:NW30:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW30:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW30:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw30")
  field(DOL, "ACSW:UNDH:NW30:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW30:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(bo, "ACSW:UNDH:NW30:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(stringin, "ACSW:UNDH:NW30:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW30:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW30:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW30:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW30:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW30:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW30:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW30:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW30:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW30:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW30:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw30")
}

record(stringin, "ACSW:UNDH:NW30:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW30:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW30:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw30")
  field(DOL, "ACSW:UNDH:NW30:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW30:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(bo, "ACSW:UNDH:NW30:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(stringin, "ACSW:UNDH:NW30:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW30:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW30:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW30:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW30:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW30:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW30:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW30:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW30:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW30:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW30:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw30")
}

record(stringin, "ACSW:UNDH:NW30:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW30:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW30:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw30")
  field(DOL, "ACSW:UNDH:NW30:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW30:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(bo, "ACSW:UNDH:NW30:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(stringin, "ACSW:UNDH:NW30:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW30:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW30:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW30:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW30:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW30:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW30:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW30:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW30:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW30:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW30:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw30")
}

record(stringin, "ACSW:UNDH:NW30:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW30:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW30:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw30")
  field(DOL, "ACSW:UNDH:NW30:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW30:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(bo, "ACSW:UNDH:NW30:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(stringin, "ACSW:UNDH:NW30:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW30:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW30:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW30:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW30:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW30:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW30:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW30:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW30:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW30:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW30:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw30")
}

record(stringin, "ACSW:UNDH:NW30:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW30:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW30:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw30")
  field(DOL, "ACSW:UNDH:NW30:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW30:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(bo, "ACSW:UNDH:NW30:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(stringin, "ACSW:UNDH:NW30:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW30:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW30:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW30:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW30:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW30:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW30:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW30:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW30:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW30:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW30:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw30")
}

record(bo, "ACSW:UNDH:NW30:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw30")
}

record(stringin, "ACSW:UNDH:NW30:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW30:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW30:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw30")
  field(DOL, "ACSW:UNDH:NW30:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW30:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(bo, "ACSW:UNDH:NW30:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw30")
  field(FLNK, "ACSW:UNDH:NW30:GETINIT")
}

record(stringin, "ACSW:UNDH:NW30:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW30:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW30:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW30:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW30:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW30:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW30:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW30:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW31:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW31) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINFO")
}

record(stringin, "ACSW:UNDH:NW31:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW31) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(stringin, "ACSW:UNDH:NW31:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW31:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW31:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW31:SITEID")
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW31:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW31:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW31) acsw-undh-nw31")
}

record(stringin, "ACSW:UNDH:NW31:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW31) acsw-undh-nw31")
}

record(ai, "ACSW:UNDH:NW31:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW31:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-31H")
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW31:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw31")
}

record(calcout, "ACSW:UNDH:NW31:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW31:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW31:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW31:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW31:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW31:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW31:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW31:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW31:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW31:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW31:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW31:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW31:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW31:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW31:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW31:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW31:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW31:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW31:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW31:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW31:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW31:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW31:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW31:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW31:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW31:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw31")
}

record(stringin, "ACSW:UNDH:NW31:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW31:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW31:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw31")
  field(DOL, "ACSW:UNDH:NW31:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW31:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(bo, "ACSW:UNDH:NW31:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(stringin, "ACSW:UNDH:NW31:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW31:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW31:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW31:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW31:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW31:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW31:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW31:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW31:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW31:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW31:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw31")
}

record(stringin, "ACSW:UNDH:NW31:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW31:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW31:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw31")
  field(DOL, "ACSW:UNDH:NW31:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW31:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(bo, "ACSW:UNDH:NW31:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(stringin, "ACSW:UNDH:NW31:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW31:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW31:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW31:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW31:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW31:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW31:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW31:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW31:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW31:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW31:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw31")
}

record(stringin, "ACSW:UNDH:NW31:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW31:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW31:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw31")
  field(DOL, "ACSW:UNDH:NW31:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW31:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(bo, "ACSW:UNDH:NW31:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(stringin, "ACSW:UNDH:NW31:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW31:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW31:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW31:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW31:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW31:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW31:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW31:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW31:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW31:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW31:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw31")
}

record(stringin, "ACSW:UNDH:NW31:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW31:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW31:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw31")
  field(DOL, "ACSW:UNDH:NW31:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW31:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(bo, "ACSW:UNDH:NW31:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(stringin, "ACSW:UNDH:NW31:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW31:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW31:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW31:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW31:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW31:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW31:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW31:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW31:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW31:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW31:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw31")
}

record(stringin, "ACSW:UNDH:NW31:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW31:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW31:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw31")
  field(DOL, "ACSW:UNDH:NW31:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW31:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(bo, "ACSW:UNDH:NW31:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(stringin, "ACSW:UNDH:NW31:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW31:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW31:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW31:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW31:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW31:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW31:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW31:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW31:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW31:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW31:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw31")
}

record(stringin, "ACSW:UNDH:NW31:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW31:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW31:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw31")
  field(DOL, "ACSW:UNDH:NW31:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW31:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(bo, "ACSW:UNDH:NW31:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(stringin, "ACSW:UNDH:NW31:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW31:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW31:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW31:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW31:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW31:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW31:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW31:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW31:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW31:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW31:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw31")
}

record(stringin, "ACSW:UNDH:NW31:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW31:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW31:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw31")
  field(DOL, "ACSW:UNDH:NW31:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW31:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(bo, "ACSW:UNDH:NW31:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(stringin, "ACSW:UNDH:NW31:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW31:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW31:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW31:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW31:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW31:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW31:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW31:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW31:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW31:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW31:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw31")
}

record(bo, "ACSW:UNDH:NW31:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw31")
}

record(stringin, "ACSW:UNDH:NW31:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW31:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW31:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw31")
  field(DOL, "ACSW:UNDH:NW31:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW31:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(bo, "ACSW:UNDH:NW31:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw31")
  field(FLNK, "ACSW:UNDH:NW31:GETINIT")
}

record(stringin, "ACSW:UNDH:NW31:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW31:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW31:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW31:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW31:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW31:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW31:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW31:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW32:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW32) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINFO")
}

record(stringin, "ACSW:UNDH:NW32:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW32) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(stringin, "ACSW:UNDH:NW32:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW32:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW32:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW32:SITEID")
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW32:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW32:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW32) acsw-undh-nw32")
}

record(stringin, "ACSW:UNDH:NW32:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW32) acsw-undh-nw32")
}

record(ai, "ACSW:UNDH:NW32:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW32:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-32H")
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW32:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw32")
}

record(calcout, "ACSW:UNDH:NW32:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW32:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW32:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW32:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW32:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW32:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW32:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW32:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW32:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW32:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW32:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW32:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW32:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW32:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW32:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW32:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW32:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW32:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW32:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW32:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW32:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW32:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW32:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW32:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW32:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW32:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw32")
}

record(stringin, "ACSW:UNDH:NW32:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW32:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW32:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw32")
  field(DOL, "ACSW:UNDH:NW32:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW32:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(bo, "ACSW:UNDH:NW32:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(stringin, "ACSW:UNDH:NW32:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW32:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW32:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW32:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW32:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW32:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW32:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW32:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW32:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW32:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW32:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw32")
}

record(stringin, "ACSW:UNDH:NW32:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW32:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW32:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw32")
  field(DOL, "ACSW:UNDH:NW32:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW32:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(bo, "ACSW:UNDH:NW32:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(stringin, "ACSW:UNDH:NW32:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW32:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW32:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW32:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW32:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW32:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW32:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW32:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW32:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW32:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW32:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw32")
}

record(stringin, "ACSW:UNDH:NW32:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW32:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW32:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw32")
  field(DOL, "ACSW:UNDH:NW32:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW32:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(bo, "ACSW:UNDH:NW32:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(stringin, "ACSW:UNDH:NW32:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW32:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW32:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW32:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW32:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW32:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW32:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW32:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW32:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW32:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW32:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw32")
}

record(stringin, "ACSW:UNDH:NW32:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW32:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW32:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw32")
  field(DOL, "ACSW:UNDH:NW32:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW32:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(bo, "ACSW:UNDH:NW32:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(stringin, "ACSW:UNDH:NW32:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW32:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW32:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW32:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW32:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW32:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW32:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW32:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW32:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW32:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW32:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw32")
}

record(stringin, "ACSW:UNDH:NW32:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW32:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW32:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw32")
  field(DOL, "ACSW:UNDH:NW32:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW32:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(bo, "ACSW:UNDH:NW32:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(stringin, "ACSW:UNDH:NW32:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW32:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW32:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW32:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW32:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW32:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW32:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW32:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW32:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW32:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW32:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw32")
}

record(stringin, "ACSW:UNDH:NW32:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW32:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW32:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw32")
  field(DOL, "ACSW:UNDH:NW32:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW32:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(bo, "ACSW:UNDH:NW32:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(stringin, "ACSW:UNDH:NW32:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW32:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW32:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW32:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW32:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW32:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW32:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW32:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW32:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW32:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW32:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw32")
}

record(stringin, "ACSW:UNDH:NW32:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW32:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW32:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw32")
  field(DOL, "ACSW:UNDH:NW32:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW32:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(bo, "ACSW:UNDH:NW32:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(stringin, "ACSW:UNDH:NW32:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW32:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW32:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW32:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW32:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW32:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW32:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW32:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW32:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW32:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW32:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw32")
}

record(bo, "ACSW:UNDH:NW32:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw32")
}

record(stringin, "ACSW:UNDH:NW32:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW32:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW32:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw32")
  field(DOL, "ACSW:UNDH:NW32:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW32:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(bo, "ACSW:UNDH:NW32:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw32")
  field(FLNK, "ACSW:UNDH:NW32:GETINIT")
}

record(stringin, "ACSW:UNDH:NW32:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW32:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW32:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW32:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW32:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW32:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW32:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW32:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW33:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW33) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINFO")
}

record(stringin, "ACSW:UNDH:NW33:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW33) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(stringin, "ACSW:UNDH:NW33:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW33:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW33:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW33:SITEID")
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW33:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW33:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW33) acsw-undh-nw33")
}

record(stringin, "ACSW:UNDH:NW33:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW33) acsw-undh-nw33")
}

record(ai, "ACSW:UNDH:NW33:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW33:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-33H")
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW33:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw33")
}

record(calcout, "ACSW:UNDH:NW33:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW33:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW33:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW33:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW33:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW33:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW33:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW33:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW33:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW33:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW33:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW33:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW33:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW33:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW33:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW33:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW33:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW33:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW33:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW33:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW33:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW33:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW33:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW33:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW33:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW33:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw33")
}

record(stringin, "ACSW:UNDH:NW33:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW33:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW33:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw33")
  field(DOL, "ACSW:UNDH:NW33:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW33:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(bo, "ACSW:UNDH:NW33:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(stringin, "ACSW:UNDH:NW33:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW33:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW33:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW33:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW33:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW33:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW33:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW33:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW33:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW33:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW33:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw33")
}

record(stringin, "ACSW:UNDH:NW33:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW33:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW33:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw33")
  field(DOL, "ACSW:UNDH:NW33:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW33:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(bo, "ACSW:UNDH:NW33:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(stringin, "ACSW:UNDH:NW33:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW33:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW33:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW33:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW33:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW33:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW33:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW33:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW33:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW33:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW33:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw33")
}

record(stringin, "ACSW:UNDH:NW33:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW33:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW33:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw33")
  field(DOL, "ACSW:UNDH:NW33:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW33:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(bo, "ACSW:UNDH:NW33:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(stringin, "ACSW:UNDH:NW33:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW33:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW33:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW33:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW33:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW33:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW33:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW33:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW33:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW33:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW33:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw33")
}

record(stringin, "ACSW:UNDH:NW33:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW33:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW33:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw33")
  field(DOL, "ACSW:UNDH:NW33:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW33:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(bo, "ACSW:UNDH:NW33:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(stringin, "ACSW:UNDH:NW33:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW33:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW33:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW33:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW33:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW33:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW33:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW33:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW33:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW33:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW33:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw33")
}

record(stringin, "ACSW:UNDH:NW33:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW33:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW33:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw33")
  field(DOL, "ACSW:UNDH:NW33:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW33:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(bo, "ACSW:UNDH:NW33:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(stringin, "ACSW:UNDH:NW33:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW33:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW33:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW33:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW33:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW33:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW33:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW33:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW33:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW33:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW33:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw33")
}

record(stringin, "ACSW:UNDH:NW33:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW33:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW33:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw33")
  field(DOL, "ACSW:UNDH:NW33:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW33:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(bo, "ACSW:UNDH:NW33:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(stringin, "ACSW:UNDH:NW33:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW33:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW33:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW33:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW33:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW33:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW33:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW33:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW33:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW33:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW33:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw33")
}

record(stringin, "ACSW:UNDH:NW33:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW33:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW33:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw33")
  field(DOL, "ACSW:UNDH:NW33:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW33:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(bo, "ACSW:UNDH:NW33:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(stringin, "ACSW:UNDH:NW33:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW33:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW33:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW33:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW33:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW33:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW33:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW33:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW33:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW33:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW33:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw33")
}

record(bo, "ACSW:UNDH:NW33:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw33")
}

record(stringin, "ACSW:UNDH:NW33:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW33:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW33:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw33")
  field(DOL, "ACSW:UNDH:NW33:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW33:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(bo, "ACSW:UNDH:NW33:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw33")
  field(FLNK, "ACSW:UNDH:NW33:GETINIT")
}

record(stringin, "ACSW:UNDH:NW33:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW33:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW33:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW33:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW33:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW33:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW33:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW33:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW34:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW34) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINFO")
}

record(stringin, "ACSW:UNDH:NW34:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW34) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(stringin, "ACSW:UNDH:NW34:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW34:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW34:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW34:SITEID")
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW34:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW34:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW34) acsw-undh-nw34")
}

record(stringin, "ACSW:UNDH:NW34:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW34) acsw-undh-nw34")
}

record(ai, "ACSW:UNDH:NW34:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW34:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-34H")
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW34:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw34")
}

record(calcout, "ACSW:UNDH:NW34:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW34:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW34:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW34:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW34:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW34:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW34:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW34:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW34:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW34:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW34:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW34:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW34:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW34:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW34:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW34:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW34:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW34:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW34:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW34:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW34:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW34:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW34:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW34:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW34:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW34:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw34")
}

record(stringin, "ACSW:UNDH:NW34:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW34:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW34:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw34")
  field(DOL, "ACSW:UNDH:NW34:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW34:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(bo, "ACSW:UNDH:NW34:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(stringin, "ACSW:UNDH:NW34:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW34:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW34:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW34:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW34:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW34:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW34:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW34:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW34:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW34:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW34:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw34")
}

record(stringin, "ACSW:UNDH:NW34:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW34:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW34:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw34")
  field(DOL, "ACSW:UNDH:NW34:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW34:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(bo, "ACSW:UNDH:NW34:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(stringin, "ACSW:UNDH:NW34:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW34:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW34:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW34:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW34:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW34:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW34:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW34:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW34:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW34:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW34:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw34")
}

record(stringin, "ACSW:UNDH:NW34:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW34:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW34:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw34")
  field(DOL, "ACSW:UNDH:NW34:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW34:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(bo, "ACSW:UNDH:NW34:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(stringin, "ACSW:UNDH:NW34:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW34:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW34:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW34:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW34:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW34:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW34:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW34:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW34:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW34:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW34:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw34")
}

record(stringin, "ACSW:UNDH:NW34:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW34:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW34:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw34")
  field(DOL, "ACSW:UNDH:NW34:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW34:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(bo, "ACSW:UNDH:NW34:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(stringin, "ACSW:UNDH:NW34:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW34:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW34:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW34:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW34:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW34:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW34:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW34:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW34:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW34:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW34:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw34")
}

record(stringin, "ACSW:UNDH:NW34:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW34:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW34:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw34")
  field(DOL, "ACSW:UNDH:NW34:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW34:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(bo, "ACSW:UNDH:NW34:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(stringin, "ACSW:UNDH:NW34:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW34:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW34:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW34:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW34:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW34:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW34:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW34:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW34:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW34:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW34:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw34")
}

record(stringin, "ACSW:UNDH:NW34:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW34:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW34:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw34")
  field(DOL, "ACSW:UNDH:NW34:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW34:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(bo, "ACSW:UNDH:NW34:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(stringin, "ACSW:UNDH:NW34:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW34:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW34:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW34:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW34:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW34:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW34:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW34:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW34:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW34:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW34:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw34")
}

record(stringin, "ACSW:UNDH:NW34:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW34:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW34:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw34")
  field(DOL, "ACSW:UNDH:NW34:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW34:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(bo, "ACSW:UNDH:NW34:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(stringin, "ACSW:UNDH:NW34:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW34:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW34:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW34:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW34:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW34:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW34:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW34:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW34:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW34:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW34:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw34")
}

record(bo, "ACSW:UNDH:NW34:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw34")
}

record(stringin, "ACSW:UNDH:NW34:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW34:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW34:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw34")
  field(DOL, "ACSW:UNDH:NW34:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW34:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(bo, "ACSW:UNDH:NW34:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw34")
  field(FLNK, "ACSW:UNDH:NW34:GETINIT")
}

record(stringin, "ACSW:UNDH:NW34:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW34:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW34:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW34:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW34:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW34:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW34:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW34:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW35:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW35) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINFO")
}

record(stringin, "ACSW:UNDH:NW35:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW35) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(stringin, "ACSW:UNDH:NW35:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW35:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW35:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW35:SITEID")
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW35:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW35:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW35) acsw-undh-nw35")
}

record(stringin, "ACSW:UNDH:NW35:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW35) acsw-undh-nw35")
}

record(ai, "ACSW:UNDH:NW35:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW35:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-35H")
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW35:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw35")
}

record(calcout, "ACSW:UNDH:NW35:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW35:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW35:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW35:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW35:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW35:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW35:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW35:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW35:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW35:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW35:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW35:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW35:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW35:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW35:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW35:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW35:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW35:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW35:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW35:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW35:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW35:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW35:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW35:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW35:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW35:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw35")
}

record(stringin, "ACSW:UNDH:NW35:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW35:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW35:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw35")
  field(DOL, "ACSW:UNDH:NW35:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW35:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(bo, "ACSW:UNDH:NW35:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(stringin, "ACSW:UNDH:NW35:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW35:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW35:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW35:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW35:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW35:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW35:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW35:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW35:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW35:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW35:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw35")
}

record(stringin, "ACSW:UNDH:NW35:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW35:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW35:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw35")
  field(DOL, "ACSW:UNDH:NW35:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW35:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(bo, "ACSW:UNDH:NW35:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(stringin, "ACSW:UNDH:NW35:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW35:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW35:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW35:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW35:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW35:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW35:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW35:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW35:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW35:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW35:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw35")
}

record(stringin, "ACSW:UNDH:NW35:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW35:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW35:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw35")
  field(DOL, "ACSW:UNDH:NW35:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW35:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(bo, "ACSW:UNDH:NW35:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(stringin, "ACSW:UNDH:NW35:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW35:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW35:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW35:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW35:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW35:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW35:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW35:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW35:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW35:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW35:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw35")
}

record(stringin, "ACSW:UNDH:NW35:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW35:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW35:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw35")
  field(DOL, "ACSW:UNDH:NW35:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW35:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(bo, "ACSW:UNDH:NW35:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(stringin, "ACSW:UNDH:NW35:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW35:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW35:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW35:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW35:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW35:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW35:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW35:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW35:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW35:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW35:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw35")
}

record(stringin, "ACSW:UNDH:NW35:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW35:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW35:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw35")
  field(DOL, "ACSW:UNDH:NW35:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW35:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(bo, "ACSW:UNDH:NW35:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(stringin, "ACSW:UNDH:NW35:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW35:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW35:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW35:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW35:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW35:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW35:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW35:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW35:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW35:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW35:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw35")
}

record(stringin, "ACSW:UNDH:NW35:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW35:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW35:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw35")
  field(DOL, "ACSW:UNDH:NW35:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW35:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(bo, "ACSW:UNDH:NW35:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(stringin, "ACSW:UNDH:NW35:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW35:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW35:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW35:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW35:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW35:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW35:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW35:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW35:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW35:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW35:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw35")
}

record(stringin, "ACSW:UNDH:NW35:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW35:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW35:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw35")
  field(DOL, "ACSW:UNDH:NW35:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW35:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(bo, "ACSW:UNDH:NW35:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(stringin, "ACSW:UNDH:NW35:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW35:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW35:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW35:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW35:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW35:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW35:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW35:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW35:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW35:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW35:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw35")
}

record(bo, "ACSW:UNDH:NW35:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw35")
}

record(stringin, "ACSW:UNDH:NW35:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW35:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW35:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw35")
  field(DOL, "ACSW:UNDH:NW35:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW35:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(bo, "ACSW:UNDH:NW35:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw35")
  field(FLNK, "ACSW:UNDH:NW35:GETINIT")
}

record(stringin, "ACSW:UNDH:NW35:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW35:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW35:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW35:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW35:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW35:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW35:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW35:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW36:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW36) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINFO")
}

record(stringin, "ACSW:UNDH:NW36:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW36) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(stringin, "ACSW:UNDH:NW36:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW36:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW36:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW36:SITEID")
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW36:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW36:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW36) acsw-undh-nw36")
}

record(stringin, "ACSW:UNDH:NW36:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW36) acsw-undh-nw36")
}

record(ai, "ACSW:UNDH:NW36:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW36:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-36H")
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW36:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw36")
}

record(calcout, "ACSW:UNDH:NW36:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW36:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW36:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW36:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW36:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW36:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW36:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW36:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW36:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW36:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW36:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW36:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW36:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW36:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW36:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW36:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW36:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW36:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW36:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW36:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW36:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW36:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW36:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW36:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW36:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW36:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw36")
}

record(stringin, "ACSW:UNDH:NW36:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW36:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW36:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw36")
  field(DOL, "ACSW:UNDH:NW36:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW36:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(bo, "ACSW:UNDH:NW36:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(stringin, "ACSW:UNDH:NW36:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW36:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW36:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW36:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW36:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW36:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW36:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW36:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW36:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW36:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW36:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw36")
}

record(stringin, "ACSW:UNDH:NW36:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW36:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW36:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw36")
  field(DOL, "ACSW:UNDH:NW36:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW36:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(bo, "ACSW:UNDH:NW36:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(stringin, "ACSW:UNDH:NW36:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW36:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW36:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW36:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW36:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW36:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW36:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW36:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW36:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW36:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW36:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw36")
}

record(stringin, "ACSW:UNDH:NW36:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW36:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW36:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw36")
  field(DOL, "ACSW:UNDH:NW36:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW36:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(bo, "ACSW:UNDH:NW36:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(stringin, "ACSW:UNDH:NW36:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW36:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW36:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW36:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW36:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW36:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW36:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW36:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW36:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW36:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW36:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw36")
}

record(stringin, "ACSW:UNDH:NW36:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW36:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW36:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw36")
  field(DOL, "ACSW:UNDH:NW36:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW36:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(bo, "ACSW:UNDH:NW36:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(stringin, "ACSW:UNDH:NW36:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW36:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW36:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW36:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW36:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW36:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW36:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW36:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW36:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW36:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW36:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw36")
}

record(stringin, "ACSW:UNDH:NW36:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW36:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW36:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw36")
  field(DOL, "ACSW:UNDH:NW36:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW36:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(bo, "ACSW:UNDH:NW36:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(stringin, "ACSW:UNDH:NW36:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW36:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW36:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW36:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW36:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW36:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW36:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW36:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW36:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW36:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW36:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw36")
}

record(stringin, "ACSW:UNDH:NW36:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW36:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW36:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw36")
  field(DOL, "ACSW:UNDH:NW36:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW36:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(bo, "ACSW:UNDH:NW36:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(stringin, "ACSW:UNDH:NW36:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW36:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW36:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW36:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW36:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW36:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW36:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW36:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW36:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW36:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW36:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw36")
}

record(stringin, "ACSW:UNDH:NW36:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW36:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW36:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw36")
  field(DOL, "ACSW:UNDH:NW36:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW36:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(bo, "ACSW:UNDH:NW36:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(stringin, "ACSW:UNDH:NW36:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW36:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW36:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW36:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW36:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW36:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW36:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW36:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW36:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW36:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW36:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw36")
}

record(bo, "ACSW:UNDH:NW36:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw36")
}

record(stringin, "ACSW:UNDH:NW36:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW36:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW36:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw36")
  field(DOL, "ACSW:UNDH:NW36:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW36:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(bo, "ACSW:UNDH:NW36:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw36")
  field(FLNK, "ACSW:UNDH:NW36:GETINIT")
}

record(stringin, "ACSW:UNDH:NW36:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW36:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW36:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW36:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW36:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW36:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW36:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW36:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW37:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW37) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINFO")
}

record(stringin, "ACSW:UNDH:NW37:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW37) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(stringin, "ACSW:UNDH:NW37:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW37:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW37:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW37:SITEID")
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW37:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW37:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW37) acsw-undh-nw37")
}

record(stringin, "ACSW:UNDH:NW37:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW37) acsw-undh-nw37")
}

record(ai, "ACSW:UNDH:NW37:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW37:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-37H")
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW37:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw37")
}

record(calcout, "ACSW:UNDH:NW37:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW37:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW37:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW37:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW37:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW37:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW37:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW37:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW37:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW37:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW37:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW37:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW37:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW37:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW37:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW37:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW37:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW37:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW37:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW37:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW37:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW37:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW37:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW37:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW37:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW37:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw37")
}

record(stringin, "ACSW:UNDH:NW37:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW37:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW37:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw37")
  field(DOL, "ACSW:UNDH:NW37:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW37:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(bo, "ACSW:UNDH:NW37:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(stringin, "ACSW:UNDH:NW37:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW37:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW37:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW37:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW37:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW37:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW37:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW37:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW37:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW37:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW37:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw37")
}

record(stringin, "ACSW:UNDH:NW37:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW37:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW37:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw37")
  field(DOL, "ACSW:UNDH:NW37:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW37:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(bo, "ACSW:UNDH:NW37:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(stringin, "ACSW:UNDH:NW37:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW37:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW37:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW37:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW37:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW37:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW37:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW37:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW37:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW37:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW37:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw37")
}

record(stringin, "ACSW:UNDH:NW37:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW37:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW37:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw37")
  field(DOL, "ACSW:UNDH:NW37:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW37:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(bo, "ACSW:UNDH:NW37:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(stringin, "ACSW:UNDH:NW37:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW37:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW37:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW37:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW37:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW37:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW37:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW37:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW37:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW37:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW37:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw37")
}

record(stringin, "ACSW:UNDH:NW37:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW37:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW37:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw37")
  field(DOL, "ACSW:UNDH:NW37:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW37:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(bo, "ACSW:UNDH:NW37:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(stringin, "ACSW:UNDH:NW37:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW37:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW37:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW37:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW37:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW37:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW37:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW37:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW37:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW37:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW37:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw37")
}

record(stringin, "ACSW:UNDH:NW37:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW37:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW37:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw37")
  field(DOL, "ACSW:UNDH:NW37:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW37:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(bo, "ACSW:UNDH:NW37:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(stringin, "ACSW:UNDH:NW37:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW37:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW37:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW37:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW37:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW37:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW37:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW37:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW37:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW37:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW37:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw37")
}

record(stringin, "ACSW:UNDH:NW37:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW37:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW37:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw37")
  field(DOL, "ACSW:UNDH:NW37:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW37:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(bo, "ACSW:UNDH:NW37:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(stringin, "ACSW:UNDH:NW37:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW37:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW37:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW37:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW37:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW37:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW37:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW37:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW37:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW37:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW37:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw37")
}

record(stringin, "ACSW:UNDH:NW37:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW37:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW37:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw37")
  field(DOL, "ACSW:UNDH:NW37:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW37:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(bo, "ACSW:UNDH:NW37:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(stringin, "ACSW:UNDH:NW37:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW37:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW37:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW37:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW37:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW37:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW37:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW37:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW37:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW37:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW37:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw37")
}

record(bo, "ACSW:UNDH:NW37:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw37")
}

record(stringin, "ACSW:UNDH:NW37:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW37:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW37:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw37")
  field(DOL, "ACSW:UNDH:NW37:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW37:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(bo, "ACSW:UNDH:NW37:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw37")
  field(FLNK, "ACSW:UNDH:NW37:GETINIT")
}

record(stringin, "ACSW:UNDH:NW37:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW37:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW37:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW37:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW37:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW37:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW37:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW37:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW38:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW38) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINFO")
}

record(stringin, "ACSW:UNDH:NW38:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW38) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(stringin, "ACSW:UNDH:NW38:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW38:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW38:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW38:SITEID")
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW38:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW38:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW38) acsw-undh-nw38")
}

record(stringin, "ACSW:UNDH:NW38:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW38) acsw-undh-nw38")
}

record(ai, "ACSW:UNDH:NW38:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW38:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-38H")
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW38:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw38")
}

record(calcout, "ACSW:UNDH:NW38:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW38:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW38:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW38:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW38:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW38:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW38:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW38:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW38:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW38:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW38:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW38:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW38:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW38:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW38:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW38:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW38:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW38:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW38:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW38:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW38:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW38:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW38:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW38:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW38:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW38:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw38")
}

record(stringin, "ACSW:UNDH:NW38:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW38:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW38:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw38")
  field(DOL, "ACSW:UNDH:NW38:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW38:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(bo, "ACSW:UNDH:NW38:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(stringin, "ACSW:UNDH:NW38:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW38:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW38:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW38:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW38:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW38:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW38:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW38:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW38:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW38:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW38:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw38")
}

record(stringin, "ACSW:UNDH:NW38:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW38:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW38:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw38")
  field(DOL, "ACSW:UNDH:NW38:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW38:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(bo, "ACSW:UNDH:NW38:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(stringin, "ACSW:UNDH:NW38:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW38:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW38:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW38:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW38:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW38:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW38:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW38:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW38:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW38:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW38:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw38")
}

record(stringin, "ACSW:UNDH:NW38:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW38:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW38:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw38")
  field(DOL, "ACSW:UNDH:NW38:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW38:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(bo, "ACSW:UNDH:NW38:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(stringin, "ACSW:UNDH:NW38:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW38:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW38:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW38:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW38:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW38:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW38:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW38:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW38:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW38:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW38:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw38")
}

record(stringin, "ACSW:UNDH:NW38:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW38:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW38:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw38")
  field(DOL, "ACSW:UNDH:NW38:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW38:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(bo, "ACSW:UNDH:NW38:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(stringin, "ACSW:UNDH:NW38:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW38:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW38:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW38:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW38:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW38:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW38:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW38:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW38:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW38:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW38:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw38")
}

record(stringin, "ACSW:UNDH:NW38:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW38:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW38:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw38")
  field(DOL, "ACSW:UNDH:NW38:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW38:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(bo, "ACSW:UNDH:NW38:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(stringin, "ACSW:UNDH:NW38:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW38:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW38:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW38:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW38:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW38:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW38:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW38:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW38:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW38:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW38:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw38")
}

record(stringin, "ACSW:UNDH:NW38:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW38:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW38:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw38")
  field(DOL, "ACSW:UNDH:NW38:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW38:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(bo, "ACSW:UNDH:NW38:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(stringin, "ACSW:UNDH:NW38:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW38:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW38:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW38:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW38:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW38:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW38:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW38:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW38:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW38:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW38:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw38")
}

record(stringin, "ACSW:UNDH:NW38:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW38:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW38:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw38")
  field(DOL, "ACSW:UNDH:NW38:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW38:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(bo, "ACSW:UNDH:NW38:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(stringin, "ACSW:UNDH:NW38:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW38:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW38:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW38:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW38:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW38:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW38:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW38:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW38:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW38:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW38:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw38")
}

record(bo, "ACSW:UNDH:NW38:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw38")
}

record(stringin, "ACSW:UNDH:NW38:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW38:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW38:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw38")
  field(DOL, "ACSW:UNDH:NW38:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW38:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(bo, "ACSW:UNDH:NW38:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw38")
  field(FLNK, "ACSW:UNDH:NW38:GETINIT")
}

record(stringin, "ACSW:UNDH:NW38:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW38:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW38:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW38:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW38:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW38:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW38:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW38:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW39:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW39) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINFO")
}

record(stringin, "ACSW:UNDH:NW39:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW39) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(stringin, "ACSW:UNDH:NW39:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW39:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW39:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW39:SITEID")
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW39:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW39:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW39) acsw-undh-nw39")
}

record(stringin, "ACSW:UNDH:NW39:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW39) acsw-undh-nw39")
}

record(ai, "ACSW:UNDH:NW39:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW39:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-39H")
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW39:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw39")
}

record(calcout, "ACSW:UNDH:NW39:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW39:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW39:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW39:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW39:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW39:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW39:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW39:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW39:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW39:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW39:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW39:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW39:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW39:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW39:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW39:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW39:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW39:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW39:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW39:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW39:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW39:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW39:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW39:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW39:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW39:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw39")
}

record(stringin, "ACSW:UNDH:NW39:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW39:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW39:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw39")
  field(DOL, "ACSW:UNDH:NW39:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW39:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(bo, "ACSW:UNDH:NW39:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(stringin, "ACSW:UNDH:NW39:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW39:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW39:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW39:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW39:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW39:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW39:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW39:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW39:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW39:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW39:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw39")
}

record(stringin, "ACSW:UNDH:NW39:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW39:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW39:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw39")
  field(DOL, "ACSW:UNDH:NW39:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW39:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(bo, "ACSW:UNDH:NW39:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(stringin, "ACSW:UNDH:NW39:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW39:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW39:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW39:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW39:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW39:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW39:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW39:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW39:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW39:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW39:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw39")
}

record(stringin, "ACSW:UNDH:NW39:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW39:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW39:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw39")
  field(DOL, "ACSW:UNDH:NW39:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW39:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(bo, "ACSW:UNDH:NW39:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(stringin, "ACSW:UNDH:NW39:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW39:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW39:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW39:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW39:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW39:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW39:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW39:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW39:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW39:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW39:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw39")
}

record(stringin, "ACSW:UNDH:NW39:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW39:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW39:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw39")
  field(DOL, "ACSW:UNDH:NW39:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW39:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(bo, "ACSW:UNDH:NW39:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(stringin, "ACSW:UNDH:NW39:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW39:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW39:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW39:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW39:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW39:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW39:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW39:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW39:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW39:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW39:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw39")
}

record(stringin, "ACSW:UNDH:NW39:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW39:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW39:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw39")
  field(DOL, "ACSW:UNDH:NW39:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW39:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(bo, "ACSW:UNDH:NW39:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(stringin, "ACSW:UNDH:NW39:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW39:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW39:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW39:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW39:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW39:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW39:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW39:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW39:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW39:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW39:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw39")
}

record(stringin, "ACSW:UNDH:NW39:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW39:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW39:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw39")
  field(DOL, "ACSW:UNDH:NW39:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW39:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(bo, "ACSW:UNDH:NW39:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(stringin, "ACSW:UNDH:NW39:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW39:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW39:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW39:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW39:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW39:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW39:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW39:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW39:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW39:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW39:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw39")
}

record(stringin, "ACSW:UNDH:NW39:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW39:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW39:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw39")
  field(DOL, "ACSW:UNDH:NW39:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW39:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(bo, "ACSW:UNDH:NW39:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(stringin, "ACSW:UNDH:NW39:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW39:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW39:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW39:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW39:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW39:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW39:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW39:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW39:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW39:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW39:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw39")
}

record(bo, "ACSW:UNDH:NW39:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw39")
}

record(stringin, "ACSW:UNDH:NW39:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW39:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW39:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw39")
  field(DOL, "ACSW:UNDH:NW39:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW39:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(bo, "ACSW:UNDH:NW39:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw39")
  field(FLNK, "ACSW:UNDH:NW39:GETINIT")
}

record(stringin, "ACSW:UNDH:NW39:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW39:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW39:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW39:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW39:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW39:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW39:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW39:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW40:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW40) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINFO")
}

record(stringin, "ACSW:UNDH:NW40:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW40) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(stringin, "ACSW:UNDH:NW40:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW40:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW40:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW40:SITEID")
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW40:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW40:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW40) acsw-undh-nw40")
}

record(stringin, "ACSW:UNDH:NW40:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW40) acsw-undh-nw40")
}

record(ai, "ACSW:UNDH:NW40:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW40:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-40H")
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW40:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw40")
}

record(calcout, "ACSW:UNDH:NW40:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW40:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW40:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW40:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW40:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW40:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW40:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW40:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW40:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW40:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW40:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW40:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW40:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW40:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW40:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW40:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW40:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW40:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW40:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW40:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW40:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW40:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW40:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW40:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW40:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW40:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw40")
}

record(stringin, "ACSW:UNDH:NW40:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW40:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW40:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw40")
  field(DOL, "ACSW:UNDH:NW40:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW40:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(bo, "ACSW:UNDH:NW40:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(stringin, "ACSW:UNDH:NW40:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW40:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW40:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW40:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW40:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW40:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW40:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW40:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW40:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW40:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW40:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw40")
}

record(stringin, "ACSW:UNDH:NW40:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW40:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW40:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw40")
  field(DOL, "ACSW:UNDH:NW40:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW40:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(bo, "ACSW:UNDH:NW40:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(stringin, "ACSW:UNDH:NW40:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW40:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW40:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW40:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW40:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW40:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW40:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW40:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW40:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW40:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW40:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw40")
}

record(stringin, "ACSW:UNDH:NW40:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW40:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW40:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw40")
  field(DOL, "ACSW:UNDH:NW40:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW40:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(bo, "ACSW:UNDH:NW40:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(stringin, "ACSW:UNDH:NW40:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW40:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW40:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW40:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW40:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW40:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW40:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW40:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW40:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW40:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW40:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw40")
}

record(stringin, "ACSW:UNDH:NW40:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW40:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW40:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw40")
  field(DOL, "ACSW:UNDH:NW40:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW40:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(bo, "ACSW:UNDH:NW40:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(stringin, "ACSW:UNDH:NW40:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW40:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW40:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW40:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW40:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW40:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW40:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW40:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW40:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW40:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW40:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw40")
}

record(stringin, "ACSW:UNDH:NW40:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW40:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW40:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw40")
  field(DOL, "ACSW:UNDH:NW40:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW40:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(bo, "ACSW:UNDH:NW40:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(stringin, "ACSW:UNDH:NW40:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW40:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW40:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW40:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW40:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW40:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW40:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW40:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW40:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW40:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW40:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw40")
}

record(stringin, "ACSW:UNDH:NW40:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW40:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW40:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw40")
  field(DOL, "ACSW:UNDH:NW40:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW40:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(bo, "ACSW:UNDH:NW40:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(stringin, "ACSW:UNDH:NW40:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW40:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW40:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW40:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW40:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW40:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW40:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW40:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW40:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW40:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW40:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw40")
}

record(stringin, "ACSW:UNDH:NW40:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW40:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW40:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw40")
  field(DOL, "ACSW:UNDH:NW40:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW40:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(bo, "ACSW:UNDH:NW40:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(stringin, "ACSW:UNDH:NW40:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW40:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW40:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW40:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW40:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW40:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW40:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW40:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW40:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW40:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW40:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw40")
}

record(bo, "ACSW:UNDH:NW40:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw40")
}

record(stringin, "ACSW:UNDH:NW40:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW40:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW40:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw40")
  field(DOL, "ACSW:UNDH:NW40:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW40:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(bo, "ACSW:UNDH:NW40:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw40")
  field(FLNK, "ACSW:UNDH:NW40:GETINIT")
}

record(stringin, "ACSW:UNDH:NW40:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW40:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW40:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW40:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW40:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW40:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW40:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW40:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW41:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW41) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINFO")
}

record(stringin, "ACSW:UNDH:NW41:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW41) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(stringin, "ACSW:UNDH:NW41:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW41:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW41:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW41:SITEID")
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW41:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW41:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW41) acsw-undh-nw41")
}

record(stringin, "ACSW:UNDH:NW41:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW41) acsw-undh-nw41")
}

record(ai, "ACSW:UNDH:NW41:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW41:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-41H")
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW41:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw41")
}

record(calcout, "ACSW:UNDH:NW41:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW41:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW41:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW41:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW41:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW41:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW41:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW41:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW41:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW41:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW41:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW41:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW41:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW41:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW41:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW41:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW41:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW41:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW41:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW41:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW41:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW41:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW41:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW41:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW41:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW41:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw41")
}

record(stringin, "ACSW:UNDH:NW41:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW41:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW41:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw41")
  field(DOL, "ACSW:UNDH:NW41:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW41:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(bo, "ACSW:UNDH:NW41:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(stringin, "ACSW:UNDH:NW41:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW41:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW41:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW41:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW41:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW41:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW41:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW41:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW41:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW41:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW41:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw41")
}

record(stringin, "ACSW:UNDH:NW41:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW41:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW41:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw41")
  field(DOL, "ACSW:UNDH:NW41:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW41:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(bo, "ACSW:UNDH:NW41:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(stringin, "ACSW:UNDH:NW41:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW41:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW41:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW41:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW41:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW41:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW41:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW41:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW41:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW41:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW41:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw41")
}

record(stringin, "ACSW:UNDH:NW41:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW41:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW41:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw41")
  field(DOL, "ACSW:UNDH:NW41:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW41:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(bo, "ACSW:UNDH:NW41:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(stringin, "ACSW:UNDH:NW41:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW41:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW41:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW41:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW41:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW41:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW41:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW41:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW41:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW41:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW41:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw41")
}

record(stringin, "ACSW:UNDH:NW41:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW41:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW41:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw41")
  field(DOL, "ACSW:UNDH:NW41:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW41:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(bo, "ACSW:UNDH:NW41:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(stringin, "ACSW:UNDH:NW41:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW41:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW41:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW41:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW41:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW41:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW41:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW41:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW41:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW41:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW41:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw41")
}

record(stringin, "ACSW:UNDH:NW41:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW41:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW41:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw41")
  field(DOL, "ACSW:UNDH:NW41:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW41:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(bo, "ACSW:UNDH:NW41:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(stringin, "ACSW:UNDH:NW41:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW41:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW41:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW41:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW41:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW41:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW41:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW41:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW41:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW41:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW41:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw41")
}

record(stringin, "ACSW:UNDH:NW41:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW41:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW41:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw41")
  field(DOL, "ACSW:UNDH:NW41:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW41:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(bo, "ACSW:UNDH:NW41:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(stringin, "ACSW:UNDH:NW41:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW41:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW41:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW41:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW41:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW41:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW41:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW41:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW41:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW41:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW41:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw41")
}

record(stringin, "ACSW:UNDH:NW41:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW41:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW41:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw41")
  field(DOL, "ACSW:UNDH:NW41:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW41:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(bo, "ACSW:UNDH:NW41:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(stringin, "ACSW:UNDH:NW41:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW41:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW41:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW41:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW41:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW41:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW41:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW41:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW41:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW41:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW41:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw41")
}

record(bo, "ACSW:UNDH:NW41:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw41")
}

record(stringin, "ACSW:UNDH:NW41:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW41:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW41:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw41")
  field(DOL, "ACSW:UNDH:NW41:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW41:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(bo, "ACSW:UNDH:NW41:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw41")
  field(FLNK, "ACSW:UNDH:NW41:GETINIT")
}

record(stringin, "ACSW:UNDH:NW41:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW41:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW41:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW41:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW41:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW41:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW41:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW41:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW42:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW42) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINFO")
}

record(stringin, "ACSW:UNDH:NW42:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW42) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(stringin, "ACSW:UNDH:NW42:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW42:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW42:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW42:SITEID")
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW42:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW42:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW42) acsw-undh-nw42")
}

record(stringin, "ACSW:UNDH:NW42:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW42) acsw-undh-nw42")
}

record(ai, "ACSW:UNDH:NW42:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW42:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-42H")
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW42:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw42")
}

record(calcout, "ACSW:UNDH:NW42:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW42:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW42:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW42:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW42:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW42:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW42:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW42:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW42:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW42:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW42:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW42:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW42:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW42:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW42:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW42:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW42:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW42:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW42:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW42:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW42:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW42:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW42:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW42:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW42:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW42:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw42")
}

record(stringin, "ACSW:UNDH:NW42:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW42:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW42:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw42")
  field(DOL, "ACSW:UNDH:NW42:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW42:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(bo, "ACSW:UNDH:NW42:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(stringin, "ACSW:UNDH:NW42:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW42:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW42:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW42:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW42:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW42:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW42:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW42:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW42:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW42:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW42:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw42")
}

record(stringin, "ACSW:UNDH:NW42:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW42:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW42:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw42")
  field(DOL, "ACSW:UNDH:NW42:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW42:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(bo, "ACSW:UNDH:NW42:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(stringin, "ACSW:UNDH:NW42:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW42:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW42:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW42:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW42:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW42:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW42:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW42:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW42:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW42:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW42:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw42")
}

record(stringin, "ACSW:UNDH:NW42:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW42:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW42:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw42")
  field(DOL, "ACSW:UNDH:NW42:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW42:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(bo, "ACSW:UNDH:NW42:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(stringin, "ACSW:UNDH:NW42:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW42:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW42:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW42:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW42:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW42:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW42:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW42:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW42:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW42:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW42:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw42")
}

record(stringin, "ACSW:UNDH:NW42:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW42:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW42:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw42")
  field(DOL, "ACSW:UNDH:NW42:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW42:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(bo, "ACSW:UNDH:NW42:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(stringin, "ACSW:UNDH:NW42:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW42:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW42:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW42:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW42:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW42:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW42:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW42:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW42:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW42:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW42:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw42")
}

record(stringin, "ACSW:UNDH:NW42:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW42:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW42:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw42")
  field(DOL, "ACSW:UNDH:NW42:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW42:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(bo, "ACSW:UNDH:NW42:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(stringin, "ACSW:UNDH:NW42:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW42:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW42:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW42:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW42:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW42:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW42:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW42:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW42:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW42:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW42:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw42")
}

record(stringin, "ACSW:UNDH:NW42:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW42:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW42:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw42")
  field(DOL, "ACSW:UNDH:NW42:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW42:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(bo, "ACSW:UNDH:NW42:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(stringin, "ACSW:UNDH:NW42:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW42:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW42:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW42:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW42:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW42:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW42:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW42:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW42:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW42:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW42:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw42")
}

record(stringin, "ACSW:UNDH:NW42:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW42:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW42:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw42")
  field(DOL, "ACSW:UNDH:NW42:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW42:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(bo, "ACSW:UNDH:NW42:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(stringin, "ACSW:UNDH:NW42:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW42:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW42:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW42:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW42:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW42:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW42:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW42:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW42:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW42:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW42:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw42")
}

record(bo, "ACSW:UNDH:NW42:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw42")
}

record(stringin, "ACSW:UNDH:NW42:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW42:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW42:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw42")
  field(DOL, "ACSW:UNDH:NW42:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW42:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(bo, "ACSW:UNDH:NW42:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw42")
  field(FLNK, "ACSW:UNDH:NW42:GETINIT")
}

record(stringin, "ACSW:UNDH:NW42:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW42:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW42:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW42:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW42:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW42:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW42:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW42:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW43:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW43) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINFO")
}

record(stringin, "ACSW:UNDH:NW43:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW43) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(stringin, "ACSW:UNDH:NW43:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW43:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW43:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW43:SITEID")
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW43:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW43:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW43) acsw-undh-nw43")
}

record(stringin, "ACSW:UNDH:NW43:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW43) acsw-undh-nw43")
}

record(ai, "ACSW:UNDH:NW43:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW43:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-43H")
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW43:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw43")
}

record(calcout, "ACSW:UNDH:NW43:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW43:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW43:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW43:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW43:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW43:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW43:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW43:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW43:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW43:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW43:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW43:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW43:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW43:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW43:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW43:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW43:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW43:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW43:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW43:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW43:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW43:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW43:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW43:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW43:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW43:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw43")
}

record(stringin, "ACSW:UNDH:NW43:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW43:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW43:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw43")
  field(DOL, "ACSW:UNDH:NW43:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW43:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(bo, "ACSW:UNDH:NW43:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(stringin, "ACSW:UNDH:NW43:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW43:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW43:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW43:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW43:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW43:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW43:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW43:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW43:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW43:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW43:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw43")
}

record(stringin, "ACSW:UNDH:NW43:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW43:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW43:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw43")
  field(DOL, "ACSW:UNDH:NW43:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW43:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(bo, "ACSW:UNDH:NW43:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(stringin, "ACSW:UNDH:NW43:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW43:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW43:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW43:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW43:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW43:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW43:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW43:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW43:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW43:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW43:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw43")
}

record(stringin, "ACSW:UNDH:NW43:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW43:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW43:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw43")
  field(DOL, "ACSW:UNDH:NW43:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW43:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(bo, "ACSW:UNDH:NW43:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(stringin, "ACSW:UNDH:NW43:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW43:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW43:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW43:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW43:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW43:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW43:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW43:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW43:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW43:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW43:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw43")
}

record(stringin, "ACSW:UNDH:NW43:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW43:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW43:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw43")
  field(DOL, "ACSW:UNDH:NW43:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW43:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(bo, "ACSW:UNDH:NW43:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(stringin, "ACSW:UNDH:NW43:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW43:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW43:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW43:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW43:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW43:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW43:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW43:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW43:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW43:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW43:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw43")
}

record(stringin, "ACSW:UNDH:NW43:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW43:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW43:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw43")
  field(DOL, "ACSW:UNDH:NW43:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW43:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(bo, "ACSW:UNDH:NW43:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(stringin, "ACSW:UNDH:NW43:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW43:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW43:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW43:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW43:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW43:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW43:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW43:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW43:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW43:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW43:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw43")
}

record(stringin, "ACSW:UNDH:NW43:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW43:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW43:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw43")
  field(DOL, "ACSW:UNDH:NW43:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW43:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(bo, "ACSW:UNDH:NW43:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(stringin, "ACSW:UNDH:NW43:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW43:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW43:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW43:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW43:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW43:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW43:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW43:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW43:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW43:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW43:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw43")
}

record(stringin, "ACSW:UNDH:NW43:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW43:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW43:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw43")
  field(DOL, "ACSW:UNDH:NW43:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW43:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(bo, "ACSW:UNDH:NW43:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(stringin, "ACSW:UNDH:NW43:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW43:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW43:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW43:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW43:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW43:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW43:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW43:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW43:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW43:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW43:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw43")
}

record(bo, "ACSW:UNDH:NW43:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw43")
}

record(stringin, "ACSW:UNDH:NW43:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW43:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW43:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw43")
  field(DOL, "ACSW:UNDH:NW43:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW43:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(bo, "ACSW:UNDH:NW43:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw43")
  field(FLNK, "ACSW:UNDH:NW43:GETINIT")
}

record(stringin, "ACSW:UNDH:NW43:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW43:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW43:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW43:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW43:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW43:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW43:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW43:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW44:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW44) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINFO")
}

record(stringin, "ACSW:UNDH:NW44:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW44) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(stringin, "ACSW:UNDH:NW44:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW44:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW44:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW44:SITEID")
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW44:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW44:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW44) acsw-undh-nw44")
}

record(stringin, "ACSW:UNDH:NW44:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW44) acsw-undh-nw44")
}

record(ai, "ACSW:UNDH:NW44:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW44:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-44H")
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW44:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw44")
}

record(calcout, "ACSW:UNDH:NW44:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW44:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW44:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW44:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW44:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW44:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW44:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW44:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW44:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW44:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW44:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW44:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW44:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW44:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW44:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW44:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW44:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW44:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW44:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW44:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW44:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW44:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW44:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW44:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW44:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW44:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw44")
}

record(stringin, "ACSW:UNDH:NW44:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW44:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW44:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw44")
  field(DOL, "ACSW:UNDH:NW44:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW44:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(bo, "ACSW:UNDH:NW44:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(stringin, "ACSW:UNDH:NW44:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW44:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW44:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW44:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW44:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW44:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW44:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW44:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW44:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW44:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW44:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw44")
}

record(stringin, "ACSW:UNDH:NW44:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW44:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW44:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw44")
  field(DOL, "ACSW:UNDH:NW44:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW44:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(bo, "ACSW:UNDH:NW44:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(stringin, "ACSW:UNDH:NW44:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW44:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW44:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW44:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW44:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW44:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW44:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW44:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW44:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW44:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW44:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw44")
}

record(stringin, "ACSW:UNDH:NW44:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW44:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW44:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw44")
  field(DOL, "ACSW:UNDH:NW44:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW44:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(bo, "ACSW:UNDH:NW44:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(stringin, "ACSW:UNDH:NW44:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW44:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW44:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW44:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW44:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW44:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW44:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW44:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW44:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW44:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW44:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw44")
}

record(stringin, "ACSW:UNDH:NW44:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW44:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW44:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw44")
  field(DOL, "ACSW:UNDH:NW44:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW44:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(bo, "ACSW:UNDH:NW44:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(stringin, "ACSW:UNDH:NW44:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW44:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW44:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW44:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW44:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW44:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW44:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW44:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW44:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW44:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW44:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw44")
}

record(stringin, "ACSW:UNDH:NW44:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW44:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW44:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw44")
  field(DOL, "ACSW:UNDH:NW44:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW44:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(bo, "ACSW:UNDH:NW44:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(stringin, "ACSW:UNDH:NW44:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW44:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW44:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW44:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW44:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW44:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW44:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW44:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW44:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW44:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW44:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw44")
}

record(stringin, "ACSW:UNDH:NW44:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW44:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW44:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw44")
  field(DOL, "ACSW:UNDH:NW44:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW44:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(bo, "ACSW:UNDH:NW44:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(stringin, "ACSW:UNDH:NW44:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW44:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW44:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW44:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW44:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW44:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW44:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW44:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW44:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW44:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW44:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw44")
}

record(stringin, "ACSW:UNDH:NW44:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW44:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW44:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw44")
  field(DOL, "ACSW:UNDH:NW44:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW44:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(bo, "ACSW:UNDH:NW44:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(stringin, "ACSW:UNDH:NW44:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW44:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW44:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW44:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW44:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW44:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW44:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW44:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW44:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW44:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW44:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw44")
}

record(bo, "ACSW:UNDH:NW44:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw44")
}

record(stringin, "ACSW:UNDH:NW44:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW44:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW44:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw44")
  field(DOL, "ACSW:UNDH:NW44:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW44:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(bo, "ACSW:UNDH:NW44:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw44")
  field(FLNK, "ACSW:UNDH:NW44:GETINIT")
}

record(stringin, "ACSW:UNDH:NW44:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW44:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW44:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW44:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW44:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW44:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW44:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW44:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW45:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW45) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINFO")
}

record(stringin, "ACSW:UNDH:NW45:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW45) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(stringin, "ACSW:UNDH:NW45:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW45:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW45:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW45:SITEID")
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW45:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW45:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW45) acsw-undh-nw45")
}

record(stringin, "ACSW:UNDH:NW45:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW45) acsw-undh-nw45")
}

record(ai, "ACSW:UNDH:NW45:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW45:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-45H")
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW45:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw45")
}

record(calcout, "ACSW:UNDH:NW45:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW45:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW45:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW45:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW45:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW45:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW45:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW45:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW45:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW45:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW45:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW45:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW45:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW45:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW45:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW45:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW45:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW45:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW45:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW45:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW45:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW45:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW45:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW45:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW45:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW45:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw45")
}

record(stringin, "ACSW:UNDH:NW45:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW45:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW45:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw45")
  field(DOL, "ACSW:UNDH:NW45:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW45:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(bo, "ACSW:UNDH:NW45:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(stringin, "ACSW:UNDH:NW45:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW45:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW45:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW45:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW45:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW45:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW45:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW45:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW45:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW45:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW45:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw45")
}

record(stringin, "ACSW:UNDH:NW45:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW45:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW45:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw45")
  field(DOL, "ACSW:UNDH:NW45:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW45:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(bo, "ACSW:UNDH:NW45:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(stringin, "ACSW:UNDH:NW45:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW45:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW45:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW45:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW45:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW45:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW45:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW45:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW45:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW45:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW45:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw45")
}

record(stringin, "ACSW:UNDH:NW45:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW45:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW45:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw45")
  field(DOL, "ACSW:UNDH:NW45:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW45:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(bo, "ACSW:UNDH:NW45:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(stringin, "ACSW:UNDH:NW45:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW45:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW45:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW45:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW45:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW45:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW45:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW45:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW45:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW45:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW45:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw45")
}

record(stringin, "ACSW:UNDH:NW45:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW45:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW45:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw45")
  field(DOL, "ACSW:UNDH:NW45:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW45:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(bo, "ACSW:UNDH:NW45:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(stringin, "ACSW:UNDH:NW45:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW45:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW45:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW45:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW45:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW45:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW45:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW45:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW45:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW45:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW45:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw45")
}

record(stringin, "ACSW:UNDH:NW45:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW45:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW45:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw45")
  field(DOL, "ACSW:UNDH:NW45:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW45:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(bo, "ACSW:UNDH:NW45:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(stringin, "ACSW:UNDH:NW45:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW45:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW45:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW45:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW45:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW45:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW45:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW45:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW45:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW45:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW45:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw45")
}

record(stringin, "ACSW:UNDH:NW45:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW45:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW45:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw45")
  field(DOL, "ACSW:UNDH:NW45:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW45:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(bo, "ACSW:UNDH:NW45:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(stringin, "ACSW:UNDH:NW45:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW45:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW45:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW45:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW45:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW45:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW45:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW45:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW45:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW45:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW45:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw45")
}

record(stringin, "ACSW:UNDH:NW45:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW45:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW45:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw45")
  field(DOL, "ACSW:UNDH:NW45:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW45:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(bo, "ACSW:UNDH:NW45:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(stringin, "ACSW:UNDH:NW45:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW45:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW45:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW45:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW45:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW45:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW45:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW45:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW45:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW45:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW45:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw45")
}

record(bo, "ACSW:UNDH:NW45:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw45")
}

record(stringin, "ACSW:UNDH:NW45:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW45:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW45:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw45")
  field(DOL, "ACSW:UNDH:NW45:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW45:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(bo, "ACSW:UNDH:NW45:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw45")
  field(FLNK, "ACSW:UNDH:NW45:GETINIT")
}

record(stringin, "ACSW:UNDH:NW45:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW45:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW45:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW45:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW45:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW45:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW45:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW45:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW46:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW46) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINFO")
}

record(stringin, "ACSW:UNDH:NW46:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW46) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(stringin, "ACSW:UNDH:NW46:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW46:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW46:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW46:SITEID")
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW46:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW46:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW46) acsw-undh-nw46")
}

record(stringin, "ACSW:UNDH:NW46:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW46) acsw-undh-nw46")
}

record(ai, "ACSW:UNDH:NW46:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW46:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-46H")
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW46:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw46")
}

record(calcout, "ACSW:UNDH:NW46:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW46:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW46:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW46:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW46:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW46:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW46:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW46:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW46:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW46:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW46:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW46:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW46:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW46:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW46:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW46:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW46:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW46:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW46:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW46:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW46:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW46:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW46:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW46:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW46:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW46:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw46")
}

record(stringin, "ACSW:UNDH:NW46:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW46:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW46:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw46")
  field(DOL, "ACSW:UNDH:NW46:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW46:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(bo, "ACSW:UNDH:NW46:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(stringin, "ACSW:UNDH:NW46:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW46:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW46:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW46:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW46:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW46:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW46:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW46:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW46:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW46:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW46:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw46")
}

record(stringin, "ACSW:UNDH:NW46:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW46:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW46:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw46")
  field(DOL, "ACSW:UNDH:NW46:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW46:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(bo, "ACSW:UNDH:NW46:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(stringin, "ACSW:UNDH:NW46:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW46:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW46:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW46:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW46:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW46:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW46:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW46:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW46:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW46:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW46:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw46")
}

record(stringin, "ACSW:UNDH:NW46:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW46:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW46:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw46")
  field(DOL, "ACSW:UNDH:NW46:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW46:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(bo, "ACSW:UNDH:NW46:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(stringin, "ACSW:UNDH:NW46:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW46:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW46:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW46:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW46:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW46:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW46:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW46:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW46:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW46:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW46:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw46")
}

record(stringin, "ACSW:UNDH:NW46:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW46:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW46:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw46")
  field(DOL, "ACSW:UNDH:NW46:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW46:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(bo, "ACSW:UNDH:NW46:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(stringin, "ACSW:UNDH:NW46:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW46:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW46:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW46:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW46:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW46:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW46:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW46:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW46:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW46:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW46:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw46")
}

record(stringin, "ACSW:UNDH:NW46:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW46:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW46:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw46")
  field(DOL, "ACSW:UNDH:NW46:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW46:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(bo, "ACSW:UNDH:NW46:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(stringin, "ACSW:UNDH:NW46:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW46:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW46:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW46:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW46:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW46:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW46:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW46:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW46:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW46:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW46:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw46")
}

record(stringin, "ACSW:UNDH:NW46:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW46:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW46:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw46")
  field(DOL, "ACSW:UNDH:NW46:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW46:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(bo, "ACSW:UNDH:NW46:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(stringin, "ACSW:UNDH:NW46:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW46:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW46:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW46:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW46:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW46:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW46:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW46:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW46:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW46:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW46:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw46")
}

record(stringin, "ACSW:UNDH:NW46:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW46:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW46:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw46")
  field(DOL, "ACSW:UNDH:NW46:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW46:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(bo, "ACSW:UNDH:NW46:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(stringin, "ACSW:UNDH:NW46:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW46:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW46:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW46:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW46:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW46:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW46:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW46:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW46:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW46:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW46:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw46")
}

record(bo, "ACSW:UNDH:NW46:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw46")
}

record(stringin, "ACSW:UNDH:NW46:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW46:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW46:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw46")
  field(DOL, "ACSW:UNDH:NW46:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW46:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(bo, "ACSW:UNDH:NW46:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw46")
  field(FLNK, "ACSW:UNDH:NW46:GETINIT")
}

record(stringin, "ACSW:UNDH:NW46:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW46:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW46:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW46:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW46:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW46:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW46:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW46:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW47:LOGIN") {
  field(PINI, "YES")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db setLogin(ACSW:UNDH:NW47) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINFO")
}

record(stringin, "ACSW:UNDH:NW47:GETINFO") {
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getInfo(ACSW:UNDH:NW47) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(stringin, "ACSW:UNDH:NW47:FWVERSION") {
  field(SCAN, "10 second")
  field(FLNK, "ACSW:UNDH:NW47:NETFWVERSION")
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW47:NETFWVERSION") {
  field(DESC, "Network adapter fw vers")
  field(FLNK, "ACSW:UNDH:NW47:SITEID")
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(stringin, "ACSW:UNDH:NW47:SITEID") {
  field(DESC, "ACSW node name")
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")

}

record(bo, "ACSW:UNDH:NW47:GETINIT") {
  field(DESC, "Get outlet init states")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db getOutletInitState8(ACSW:UNDH:NW47) acsw-undh-nw47")
}

record(stringin, "ACSW:UNDH:NW47:GETSTATUS") {
  field(SCAN, "2 second")
  field(DTYP, "stream")
  field(INP, "@acsw_apc.proto.db getOutletState8(ACSW:UNDH:NW47) acsw-undh-nw47")
}

record(ai, "ACSW:UNDH:NW47:TYPE") {
  field(DESC, "APC 8 Port AC Power Switch")
  field(PINI, "YES")
  field(VAL, "10")
}

record(stringin, "ACSW:UNDH:NW47:LOC") {
  field(PINI, "YES")
  field(VAL, "B920-47H")
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
  info(autosaveFields,"VAL")
}

record(bo, "ACSW:UNDH:NW47:DISCONN") {
  field(DESC, "Disconn to allow access")
  field(DISA, "1")
  field(DISS, "NO_ALARM")
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setDisconnect acsw-undh-nw47")
}

record(calcout, "ACSW:UNDH:NW47:CONNCALC") {
  field(CALC, "A=B && C#D")
  field(SCAN, "2 second")
  field(INPA, "ACSW:UNDH:NW47:DISCONN.DISA")
  field(INPB, "ACSW:UNDH:NW47:DISCONN.DISV")
  field(INPC, "ACSW:UNDH:NW47:GETSTATUS.DISA")
  field(INPD, "ACSW:UNDH:NW47:GETSTATUS.DISV")
  field(OOPT, "On Change")
  field(OUT, "ACSW:UNDH:NW47:CONNSTA PP")
}

record(bi, "ACSW:UNDH:NW47:CONNSTA") {
  field(ZNAM, "Not connected")
  field(ONAM, "Connected")
  field(ZSV, "MINOR")
  field(OSV, "NO_ALARM")
}

# Disconnect from ACSW to allow
# other clients access to ACSW
record(seq, "ACSW:UNDH:NW47:ACCSTART") {
  field(SELM, "All")
  field(DOL1, "1")
  field(LNK1, "ACSW:UNDH:NW47:GETSTATUS.DISA")
  field(DOL2, "0")
  field(LNK2, "ACSW:UNDH:NW47:DISCONN.DISA PP")
}

# Reconnect to ACSW
record(seq, "ACSW:UNDH:NW47:ACCSTOP") {
  field(SELM, "All")
  field(DOL1, "0")
  field(LNK1, "ACSW:UNDH:NW47:GETSTATUS.DISA")
  field(DOL2, "1")
  field(LNK2, "ACSW:UNDH:NW47:DISCONN.DISA")
}

#Not in use since using CLI
record(ai, "ACSW:UNDH:NW47:UPTIMEHOUR") {
  field(FLNK, "ACSW:UNDH:NW47:UPTIMEMINUTE")
  field(EGU, "Hours")
}
record(ai, "ACSW:UNDH:NW47:UPTIMEDAY") {
  field(FLNK, "ACSW:UNDH:NW47:UPTIMEHOUR")
  field(EGU, "Days")
}
record(ai, "ACSW:UNDH:NW47:UPTIMEMINUTE") {
  field(FLNK, "ACSW:UNDH:NW47:1NAME")
  field(EGU, "Minutes")
}

record(stringin, "ACSW:UNDH:NW47:1NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:1POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW47:1POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW47:1POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW47:1POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW47:1POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW47:1POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:1POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:1POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW47:1POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(1) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:1POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(1) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:1HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(1) acsw-undh-nw47")
}

record(stringin, "ACSW:UNDH:NW47:1NAMESET") {
  field(FLNK, "ACSW:UNDH:NW47:1NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW47:1NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(1) acsw-undh-nw47")
  field(DOL, "ACSW:UNDH:NW47:1NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW47:1SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(1) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(bo, "ACSW:UNDH:NW47:1SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(1) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(stringin, "ACSW:UNDH:NW47:1INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:1INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW47:1INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW47:1INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW47:1INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:1INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:1INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW47:2NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:2POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW47:2POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW47:2POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW47:2POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW47:2POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW47:2POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:2POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:2POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW47:2POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(2) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:2POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(2) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:2HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(2) acsw-undh-nw47")
}

record(stringin, "ACSW:UNDH:NW47:2NAMESET") {
  field(FLNK, "ACSW:UNDH:NW47:2NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW47:2NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(2) acsw-undh-nw47")
  field(DOL, "ACSW:UNDH:NW47:2NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW47:2SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(2) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(bo, "ACSW:UNDH:NW47:2SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(2) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(stringin, "ACSW:UNDH:NW47:2INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:2INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW47:2INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW47:2INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW47:2INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:2INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:2INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW47:3NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:3POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW47:3POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW47:3POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW47:3POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW47:3POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW47:3POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:3POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:3POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW47:3POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(3) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:3POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(3) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:3HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(3) acsw-undh-nw47")
}

record(stringin, "ACSW:UNDH:NW47:3NAMESET") {
  field(FLNK, "ACSW:UNDH:NW47:3NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW47:3NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(3) acsw-undh-nw47")
  field(DOL, "ACSW:UNDH:NW47:3NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW47:3SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(3) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(bo, "ACSW:UNDH:NW47:3SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(3) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(stringin, "ACSW:UNDH:NW47:3INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:3INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW47:3INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW47:3INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW47:3INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:3INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:3INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW47:4NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:4POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW47:4POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW47:4POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW47:4POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW47:4POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW47:4POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:4POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:4POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW47:4POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(4) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:4POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(4) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:4HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(4) acsw-undh-nw47")
}

record(stringin, "ACSW:UNDH:NW47:4NAMESET") {
  field(FLNK, "ACSW:UNDH:NW47:4NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW47:4NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(4) acsw-undh-nw47")
  field(DOL, "ACSW:UNDH:NW47:4NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW47:4SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(4) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(bo, "ACSW:UNDH:NW47:4SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(4) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(stringin, "ACSW:UNDH:NW47:4INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:4INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW47:4INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW47:4INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW47:4INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:4INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:4INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW47:5NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:5POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW47:5POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW47:5POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW47:5POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW47:5POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW47:5POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:5POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:5POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW47:5POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(5) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:5POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(5) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:5HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(5) acsw-undh-nw47")
}

record(stringin, "ACSW:UNDH:NW47:5NAMESET") {
  field(FLNK, "ACSW:UNDH:NW47:5NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW47:5NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(5) acsw-undh-nw47")
  field(DOL, "ACSW:UNDH:NW47:5NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW47:5SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(5) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(bo, "ACSW:UNDH:NW47:5SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(5) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(stringin, "ACSW:UNDH:NW47:5INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:5INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW47:5INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW47:5INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW47:5INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:5INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:5INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW47:6NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:6POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW47:6POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW47:6POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW47:6POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW47:6POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW47:6POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:6POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:6POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW47:6POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(6) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:6POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(6) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:6HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(6) acsw-undh-nw47")
}

record(stringin, "ACSW:UNDH:NW47:6NAMESET") {
  field(FLNK, "ACSW:UNDH:NW47:6NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW47:6NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(6) acsw-undh-nw47")
  field(DOL, "ACSW:UNDH:NW47:6NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW47:6SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(6) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(bo, "ACSW:UNDH:NW47:6SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(6) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(stringin, "ACSW:UNDH:NW47:6INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:6INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW47:6INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW47:6INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW47:6INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:6INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:6INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW47:7NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:7POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW47:7POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW47:7POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW47:7POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW47:7POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW47:7POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:7POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:7POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW47:7POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(7) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:7POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(7) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:7HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(7) acsw-undh-nw47")
}

record(stringin, "ACSW:UNDH:NW47:7NAMESET") {
  field(FLNK, "ACSW:UNDH:NW47:7NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW47:7NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(7) acsw-undh-nw47")
  field(DOL, "ACSW:UNDH:NW47:7NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW47:7SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(7) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(bo, "ACSW:UNDH:NW47:7SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(7) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(stringin, "ACSW:UNDH:NW47:7INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:7INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW47:7INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW47:7INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW47:7INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:7INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:7INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}
record(stringin, "ACSW:UNDH:NW47:8NAME") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:8POWERSTATEIN")
}

record(stringin, "ACSW:UNDH:NW47:8POWERSTATEIN") {
  field(FLNK, "ACSW:UNDH:NW47:8POWERSTATESV")
}

record(scalcout, "ACSW:UNDH:NW47:8POWERSTATESV") {
  field(CALC,  "AA==BB?0:(AA==CC?1):(AA==DD?2):3")
  field(INAA, "ACSW:UNDH:NW47:8POWERSTATEIN")
  field(BB, "ON")
  field(CC, "OFF*")
  field(DD, "OFF")
  field(FLNK, "ACSW:UNDH:NW47:8POWERSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:8POWERSTATE") {
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:8POWERSTATESV")
  field(FLNK, "")
  field(ZRST, "ON")
  field(ONST, "OFF*")
  field(TWST, "OFF")
  field(THST, "UNKNOWN")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR CPP MS")
  field(DISV, "20")
}

record(bo, "ACSW:UNDH:NW47:8POWEROFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOff(8) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:8POWERON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletOn(8) acsw-undh-nw47")
}

record(bo, "ACSW:UNDH:NW47:8HARDRESET") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletHardReset(8) acsw-undh-nw47")
}

record(stringin, "ACSW:UNDH:NW47:8NAMESET") {
  field(FLNK, "ACSW:UNDH:NW47:8NAMESETGO")
  field(VAL, "")
}

record(stringout, "ACSW:UNDH:NW47:8NAMESETGO") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletName(8) acsw-undh-nw47")
  field(DOL, "ACSW:UNDH:NW47:8NAMESET")
  field(OMSL, "closed_loop")
}

record(bo, "ACSW:UNDH:NW47:8SETINITOFF") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOff(8) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(bo, "ACSW:UNDH:NW47:8SETINITON") {
  field(DTYP, "stream")
  field(OUT, "@acsw_apc.proto.db setOutletInitOn(8) acsw-undh-nw47")
  field(FLNK, "ACSW:UNDH:NW47:GETINIT")
}

record(stringin, "ACSW:UNDH:NW47:8INITSTATEIN") {
   field(DESC, "Plug device name")
   field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.SEVR")
   field(DISV, "3")
   field(DISS, "INVALID")
   field(PINI, "YES")
   field(FLNK, "ACSW:UNDH:NW47:8INITSTATESV")
}

# Currently, power on delay is always 0 or never, 
# so our 2 initial states are 'on' or 'off'.
# If we start using delays, we should modify this
# logic to display the delay. 
record(scalcout, "ACSW:UNDH:NW47:8INITSTATESV") {
  field(CALC, "AA==BB?1:0")
  field(INAA, "ACSW:UNDH:NW47:8INITSTATEIN NPP MS")
  field(BB, "never")
  field(FLNK, "ACSW:UNDH:NW47:8INITSTATE")
}

record(mbbi, "ACSW:UNDH:NW47:8INITSTATE") {
#  field(SDIS, "ACSW:UNDH:NW47:GETSTATUS.DISA NPP MS")
#  field(DISS, "INVALID")
  field(INP, "ACSW:UNDH:NW47:8INITSTATESV NPP MS")
  field(ZRST, "ON")
  field(ONST, "OFF")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
}