record(mbbo, "MODU:$(MICRO):$(CRAT)$(SLOT):MODEL") {
  field(DESC, "Module Model Name")
  field(DTYP, "Raw Soft Channel")
  field(PINI, "YES")
  field(VAL, "$(MODEL)")
  field(NOBT, "4")
  field(ZRST, "Unused")
  field(ONST, "SAM-123-603")
  field(TWST, "IDIM")
  field(THST, "IDOM")
  field(FRST, "PPOM")
  field(FVST, "PIOP")
  field(SXST, "Crate-Verifier")
  field(SVST, "DAC")
  field(EIST, "STB")
  field(NIST, "PDU-II")
  field(UNSV, "INVALID")
  field(FLNK, "MODU:$(MICRO):$(CRAT)$(SLOT):NCHAN_CALC")
}

record(calc,"MODU:$(MICRO):$(CRAT)$(SLOT):NCHAN_CALC") {
  field(DESC, "Get no of channels")
  field(ASG,  "Internal")
  field(CALC, "((A>=1)&&(A<=4))?32:A>6?16:0")
  field(INPA, "MODU:$(MICRO):$(CRAT)$(SLOT):MODEL")
  field(FLNK, "MODU:$(MICRO):$(CRAT)$(SLOT):NCHAN")
}

record(longout, "MODU:$(MICRO):$(CRAT)$(SLOT):NCHAN") {
  field(DESC, "No of Channels")
  field(EGU,  "No of Channels")
  field(DRVH, "32")
  field(HOPR, "32")
  field(OMSL, "closed_loop")
  field(DOL,  "MODU:$(MICRO):$(CRAT)$(SLOT):NCHAN_CALC")  
  field(FLNK, "MODU:$(MICRO):$(CRAT)$(SLOT):NSLOT_CALC")
}

record(calc,"MODU:$(MICRO):$(CRAT)$(SLOT):NSLOT_CALC") {
  field(DESC, "Get module width")
  field(ASG,  "Internal")
  field(CALC, "A<9?1:2")
  field(INPA, "MODU:$(MICRO):$(CRAT)$(SLOT):MODEL")
  field(FLNK, "MODU:$(MICRO):$(CRAT)$(SLOT):NSLOT")
}

record(longout, "MODU:$(MICRO):$(CRAT)$(SLOT):NSLOT") {
  field(DESC, "Module Width")
  field(EGU,  "Module Width")
  field(DRVH, "2")
  field(HOPR, "2")
  field(OMSL, "closed_loop")
  field(DOL,  "MODU:$(MICRO):$(CRAT)$(SLOT):NSLOT_CALC")
}

# Currently, these are found in IOCManager
record(longout, "MODU:$(MICRO):$(CRAT)$(SLOT):CRATE") {
  field(DESC, "Crate location")
  field(EGU,  "Crate No.")
  field(DRVH, "15")
  field(HOPR, "15")
  field(DOL,  "$(CRAT)")  
  field(PINI, "YES")
}

record(longout, "MODU:$(MICRO):$(CRAT)$(SLOT):SLOT") {
  field(DESC, "Slot location")
  field(EGU,  "Slot No.")
  field(DRVH, "25")
  field(HOPR, "25")
  field(LOPR, "0")
  field(DRVL, "0")
  field(DOL,  "$(SLOT)")  
  field(PINI, "YES")
}