#! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/fbcksimSoft.dbd") #! DBDEND ###################################### # THIS IS TO KEEP THE BLD HAPPY -- ON DEV ONLY #record(ao, "BEND:LTUH:125:BDES") { # field(DESC, "Fake PV for the BLD") # field(VAL, 1) # field(PINI, "YES") #} ###################################### record(longout, "$(IOC):$(LC):$(LP):TIMERDELAY") { field(DESC, "Delay from fiducial") field(PINI, "YES") field(VAL, "4000") field(OMSL, "supervisory") field(EGU, "usec") field(DRVH, "8300000") field(DRVL, "0") field(MDEL, "-1") field(DTYP, "FfConfig") field(OUT, "@TIMERDELAY") field(PRIO, "LOW") info(autosaveMon$(AR), "VAL") } record(waveform, "$(IOC):$(LC):$(LP):INITFUNCS") { field(DESC, "init function names") field(PINI, "YES") field(NELM, "10") field(FTVL, "STRING") } record(waveform, "$(IOC):$(LC):$(LP):ITERFUNCS") { field(DESC, "iterate function names") field(PINI, "YES") field(NELM, "10") field(FTVL, "STRING") field(DTYP, "FfConfig Waveform Read") field(INP, "@ALGORITHMS") field(SCAN, "10 second") } record(waveform, "$(IOC):$(LC):$(LP):FMATRIXFUNCS") { field(DESC, "F Matrix function names") field(PINI, "YES") field(NELM, "10") field(FTVL, "STRING") } record(waveform, "$(IOC):$(LC):$(LP):GMATRIXFUNCS") { field(DESC, "G Matrix function names") field(PINI, "YES") field(NELM, "10") field(FTVL, "STRING") } record(waveform, "$(IOC):$(LC):$(LP):RECONFIGFUNCS") { field(DESC, "reconfig function names") field(PINI, "YES") field(NELM, "10") field(FTVL, "STRING") } #! Further lines contain data used by VisualDCT #! View(2000,2115,1.0) #! Record("$(IOC):$(LC):$(LP):TIMERDELAY",2060,2231,0,1,"$(IOC):$(LC):$(LP):TIMERDELAY") #! Record("$(IOC):$(LC):$(LP):INITFUNCS",2240,2228,0,1,"$(IOC):$(LC):$(LP):INITFUNCS") #! Record("$(IOC):$(LC):$(LP):ITERFUNCS",2440,2228,0,1,"$(IOC):$(LC):$(LP):ITERFUNCS") #! Record("$(IOC):$(LC):$(LP):FMATRIXFUNCS",2240,2368,0,1,"$(IOC):$(LC):$(LP):FMATRIXFUNCS") #! Record("$(IOC):$(LC):$(LP):GMATRIXFUNCS",2440,2368,0,1,"$(IOC):$(LC):$(LP):GMATRIXFUNCS") #! Record("$(IOC):$(LC):$(LP):RECONFIGFUNCS",2640,2228,0,1,"$(IOC):$(LC):$(LP):RECONFIGFUNCS") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/fbcksimSoft.dbd") #! DBDEND record(ai, "$(IOC):$(LC):$(LP):TMITLOW_IN") { field(DESC, "Lowest TMIT") field(SCAN, "Passive") field(PINI, "YES") field(FLNK, "$(IOC):$(LC):$(LP):TMITLOW") field(VAL, "0") field(INP, "SIOC:SYS0:FB00:TMITLOW CPP MS") field(EGU, "Nel") field(PRIO, "LOW") } record(ao, "$(IOC):$(LC):$(LP):TMITLOW") { field(DESC, "Lowest TMIT") field(SCAN, "Passive") field(VAL, "0") field(DTYP, "FfConfig") field(OUT, "@TMITLOW") field(DOL, "$(IOC):$(LC):$(LP):TMITLOW_IN.VAL") field(EGU, "Nel") field(OMSL, "closed_loop") field(OIF, "Full") field(DRVH, "100e10") field(DRVL, "0") field(PRIO, "LOW") } record(ai, "$(IOC):$(LC):$(LP):BY1BDES_IN") { field(DESC, "BY1 BDES") field(SCAN, "Passive") field(PINI, "YES") field(FLNK, "$(IOC):$(LC):$(LP):BY1BDES") field(VAL, "0") field(INP, "$(BEND_MAG) CPP MS") field(EGU, "GeV/c") field(PRIO, "LOW") } record(ao, "$(IOC):$(LC):$(LP):BY1BDES") { field(DESC, "BY1 BDES") field(SCAN, "Passive") field(VAL, "0") field(DTYP, "FfConfig") field(OUT, "@BY1BDES") field(DOL, "$(IOC):$(LC):$(LP):BY1BDES_IN") field(EGU, "GeV/c") field(OMSL, "closed_loop") field(OIF, "Full") field(DRVH, "20") field(DRVL, "0") field(PRIO, "LOW") } record(ai, "$(IOC):$(LC):$(LP):LASER_PWR_READBACK_IN") { field(DESC, "Laser Power") field(SCAN, "Passive") field(PINI, "YES") field(FLNK, "$(IOC):$(LC):$(LP):LASER_PWR_READBACK") field(VAL, "0") field(INP, "IOC:IN20:LS11:LASER_PWR_READBACK CPP MS") field(EGU, "percent") field(PRIO, "LOW") } record(ao, "$(IOC):$(LC):$(LP):LASER_PWR_READBACK") { field(DESC, "Laser Power") field(SCAN, "Passive") field(VAL, "0") field(DTYP, "FfConfig") field(OUT, "@LASER_PWR_READBACK") field(DOL, "$(IOC):$(LC):$(LP):LASER_PWR_READBACK_IN") field(EGU, "percent") field(OMSL, "closed_loop") field(OIF, "Full") field(DRVH, "100") field(DRVL, "0") field(PRIO, "LOW") } #------------------------------------------------------------ # For Longitudinal feedback only (BEGIN) #------------------------------------------------------------ # DL1 Energy Reference - HXR record(ai, "$(IOC):$(LC):$(LP):DL1_EREF_IN") { field(DESC, "DL1 energy ref") field(SCAN, "Passive") field(PINI, "YES") field(FLNK, "$(IOC):$(LC):$(LP):DL1_EREF") field(VAL, "0") field(INP, "REFS:IN20:751:EDES CPP MS") field(EGU, "GeV/c") field(PRIO, "MEDIUM") } record(ao, "$(IOC):$(LC):$(LP):DL1_EREF") { field(DESC, "DL1 energy ref") field(SCAN, "Passive") field(PINI, "YES") field(VAL, "0") field(DTYP, "FfConfig") field(OUT, "@DL1_EREF") field(DOL, "$(IOC):$(LC):$(LP):DL1_EREF_IN") field(EGU, "GeV/c") field(OMSL, "closed_loop") field(OIF, "Full") field(DRVH, "20") field(DRVL, "0") field(FLNK, "FBCK:$(AR):$(LP):DL1SETPOINT") field(PRIO, "MEDIUM") } # DL1 Energy Reference - SXR record(ai, "$(IOC):$(LC):$(LP):DL1_EREF_IN_SXR") { field(DESC, "DL1 SXR energy ref") field(SCAN, "Passive") field(PINI, "YES") field(FLNK, "$(IOC):$(LC):$(LP):DL1_EREF_SXR") field(VAL, "0") field(INP, "REFS:IN20:751:EDES CPP MS") field(EGU, "GeV/c") field(PRIO, "MEDIUM") } record(ao, "$(IOC):$(LC):$(LP):DL1_EREF_SXR") { field(DESC, "DL1 SXR energy ref") field(SCAN, "Passive") field(PINI, "YES") field(VAL, "0") field(DTYP, "FfConfig") field(OUT, "@DL1_EREF_SXR") field(DOL, "$(IOC):$(LC):$(LP):DL1_EREF_IN_SXR") field(EGU, "GeV/c") field(OMSL, "closed_loop") field(OIF, "Full") field(DRVH, "20") field(DRVL, "0") field(FLNK, "FBCK:$(AR):$(LP):DL1SETPOINT_SXR") field(PRIO, "MEDIUM") } # BC1 Energy Reference - HXR record(ai, "$(IOC):$(LC):$(LP):BC1_EREF_IN") { field(DESC, "BC1 energy ref") field(SCAN, "Passive") field(PINI, "YES") field(FLNK, "$(IOC):$(LC):$(LP):BC1_EREF") field(VAL, "0") field(INP, "REFS:LI21:231:EDES CPP MS") field(EGU, "GeV/c") field(PRIO, "MEDIUM") } record(ao, "$(IOC):$(LC):$(LP):BC1_EREF") { field(DESC, "BC1 energy ref") field(SCAN, "Passive") field(PINI, "YES") field(VAL, "0") field(DTYP, "FfConfig") field(OUT, "@BC1_EREF") field(DOL, "$(IOC):$(LC):$(LP):BC1_EREF_IN") field(EGU, "GeV/c") field(OMSL, "closed_loop") field(OIF, "Full") field(DRVH, "20") field(DRVL, "0") field(FLNK, "FBCK:$(AR):$(LP):BC1SETPOINT") field(PRIO, "MEDIUM") } # BC1 Energy Reference - SXR record(ai, "$(IOC):$(LC):$(LP):BC1_EREF_IN_SXR") { field(DESC, "BC1 SXR energy ref") field(SCAN, "Passive") field(PINI, "YES") field(FLNK, "$(IOC):$(LC):$(LP):BC1_EREF_SXR") field(VAL, "0") field(INP, "REFS:LI21:231:EDES CPP MS") field(EGU, "GeV/c") field(PRIO, "MEDIUM") } record(ao, "$(IOC):$(LC):$(LP):BC1_EREF_SXR") { field(DESC, "BC1 SXR energy ref") field(SCAN, "Passive") field(PINI, "YES") field(VAL, "0") field(DTYP, "FfConfig") field(OUT, "@BC1_EREF_SXR") field(DOL, "$(IOC):$(LC):$(LP):BC1_EREF_IN_SXR") field(EGU, "GeV/c") field(OMSL, "closed_loop") field(OIF, "Full") field(DRVH, "20") field(DRVL, "0") field(FLNK, "FBCK:$(AR):$(LP):BC1SETPOINT_SXR") field(PRIO, "MEDIUM") } # BC2 Energy Reference - HXR record(ai, "$(IOC):$(LC):$(LP):BC2_EREF_IN") { field(DESC, "BC2 energy ref") field(SCAN, "Passive") field(PINI, "YES") field(FLNK, "$(IOC):$(LC):$(LP):BC2_EREF") field(VAL, "0") field(INP, "REFS:LI24:790:EDES CPP MS") field(EGU, "GeV/c") field(PRIO, "MEDIUM") } record(ao, "$(IOC):$(LC):$(LP):BC2_EREF") { field(DESC, "BC2 energy ref") field(SCAN, "Passive") field(PINI, "YES") field(VAL, "0") field(DTYP, "FfConfig") field(OUT, "@BC2_EREF") field(DOL, "$(IOC):$(LC):$(LP):BC2_EREF_IN") field(EGU, "GeV/c") field(OMSL, "closed_loop") field(OIF, "Full") field(DRVH, "20") field(DRVL, "0") field(FLNK, "FBCK:$(AR):$(LP):BC2SETPOINT") field(PRIO, "MEDIUM") } # BC2 Energy Reference - SXR record(ai, "$(IOC):$(LC):$(LP):BC2_EREF_IN_SXR") { field(DESC, "BC2 SXR energy ref") field(SCAN, "Passive") field(PINI, "YES") field(FLNK, "$(IOC):$(LC):$(LP):BC2_EREF_SXR") field(VAL, "0") field(INP, "REFS:LI24:790:EDES CPP MS") field(EGU, "GeV/c") field(PRIO, "MEDIUM") } record(ao, "$(IOC):$(LC):$(LP):BC2_EREF_SXR") { field(DESC, "BC2 SXR energy ref") field(SCAN, "Passive") field(PINI, "YES") field(VAL, "0") field(DTYP, "FfConfig") field(OUT, "@BC2_EREF_SXR") field(DOL, "$(IOC):$(LC):$(LP):BC2_EREF_IN_SXR") field(EGU, "GeV/c") field(OMSL, "closed_loop") field(OIF, "Full") field(DRVH, "20") field(DRVL, "0") field(FLNK, "FBCK:$(AR):$(LP):BC2SETPOINT_SXR") field(PRIO, "MEDIUM") } # DL2 Energy Reference - HXR record(ai, "$(IOC):$(LC):$(LP):DL2_EREF_IN") { field(DESC, "DL2 energy ref") field(SCAN, "Passive") field(PINI, "YES") field(FLNK, "$(IOC):$(LC):$(LP):DL2_EREF") field(VAL, "0") field(INP, "REFS:DMPH:400:EDES CPP MS") field(EGU, "GeV/c") field(PRIO, "MEDIUM") } record(ao, "$(IOC):$(LC):$(LP):DL2_EREF") { field(DESC, "DL2 energy ref") field(SCAN, "Passive") field(PINI, "YES") field(VAL, "0") field(DTYP, "FfConfig") field(OUT, "@DL2_EREF") field(DOL, "$(IOC):$(LC):$(LP):DL2_EREF_IN") field(EGU, "GeV/c") field(OMSL, "closed_loop") field(OIF, "Full") field(DRVH, "20") field(DRVL, "0") field(FLNK, "FBCK:$(AR):$(LP):DL2SETPOINT") field(PRIO, "MEDIUM") } # DL2 Energy Reference - SXR record(ai, "$(IOC):$(LC):$(LP):DL2_EREF_IN_SXR") { field(DESC, "DL2 SXR energy ref") field(SCAN, "Passive") field(PINI, "YES") field(FLNK, "$(IOC):$(LC):$(LP):DL2_EREF_SXR") field(VAL, "0") field(INP, "REFS:DMPH:400:EDES CPP MS") field(EGU, "GeV/c") field(PRIO, "MEDIUM") } record(ao, "$(IOC):$(LC):$(LP):DL2_EREF_SXR") { field(DESC, "DL2 SXR energy ref") field(SCAN, "Passive") field(PINI, "YES") field(VAL, "0") field(DTYP, "FfConfig") field(OUT, "@DL2_EREF_SXR") field(DOL, "$(IOC):$(LC):$(LP):DL2_EREF_IN_SXR") field(EGU, "GeV/c") field(OMSL, "closed_loop") field(OIF, "Full") field(DRVH, "20") field(DRVL, "0") field(FLNK, "FBCK:$(AR):$(LP):DL2SETPOINT_SXR") field(PRIO, "MEDIUM") } #------------------------------------------------------------ # For Longitudinal feedback only (END) #------------------------------------------------------------ #record(ai, "$(IOC):$(LC):$(LP):LI21LVPOS_IN") { # field(DESC, "Dispr. in LI21") # field(SCAN, "Passive") # field(PINI, "YES") # field(FLNK, "$(IOC):$(LC):$(LP):LI21LVPOS") # field(VAL, "0") # field(INP, "BMLN:LI21:235:LVPOS CPP MS") # field(EGU, "mm") # field(PRIO, "LOW") #} # #record(ao, "$(IOC):$(LC):$(LP):LI21LVPOS") { # field(DESC, "dispr. in LI21") # field(SCAN, "Passive") # field(VAL, "0") # field(DTYP, "FfConfig") # field(OUT, "@LI21LVPOS") # field(DOL, "$(IOC):$(LC):$(LP):LI21LVPOS_IN") # field(EGU, "mm") # field(OMSL, "closed_loop") # field(OIF, "Full") # field(DRVH, "1000") # field(DRVL, "0") # field(PRIO, "LOW") #} # #record(ai, "$(IOC):$(LC):$(LP):LI24LVPOS_IN") { # field(DESC, "dispr. in LI24") # field(SCAN, "Passive") # field(PINI, "YES") # field(FLNK, "$(IOC):$(LC):$(LP):LI24LVPOS") # field(VAL, "0") # field(INP, "BMLN:LI24:805:LVPOS CPP MS") # field(EGU, "mm") # field(PRIO, "LOW") #} # #record(ao, "$(IOC):$(LC):$(LP):LI24LVPOS") { # field(DESC, "dispr. in LI24") # field(SCAN, "Passive") # field(VAL, "0") # field(DTYP, "FfConfig") # field(OUT, "@LI24LVPOS") # field(DOL, "$(IOC):$(LC):$(LP):LI24LVPOS_IN") # field(EGU, "mm") # field(OMSL, "closed_loop") # field(OIF, "Full") # field(DRVH, "1000") # field(DRVL, "0") # field(PRIO, "LOW") #} #record(ao, "$(IOC):$(LC):$(LP):DL2ENLOLO") { # field(DESC, "DL2 Energy LOLO") # field(SCAN, "Passive") # field(VAL, "0") # field(DTYP, "FfConfig") # field(OUT, "@DL2ENLOLO") # field(DOL, "$(IOC):$(LC):$(LP):DL2ENLOLO_IN.VAL") # field(EGU, "kG-m") # field(OMSL, "closed_loop") # field(OIF, "Full") # field(DRVH, "15000") # field(DRVL, "-3000") # field(PRIO, "LOW") #} # #record(ao, "$(IOC):$(LC):$(LP):DL2ENHIHI") { # field(DESC, "DL2 Energy HIHI") # field(SCAN, "Passive") # field(VAL, "0") # field(DTYP, "FfConfig") # field(OUT, "@DL2ENHIHI") # field(DOL, "$(IOC):$(LC):$(LP):DL2ENHIHI_IN.VAL") # field(EGU, "kG-m") # field(OMSL, "closed_loop") # field(OIF, "Full") # field(DRVH, "15000") # field(DRVL, "-3000") # field(PRIO, "LOW") #} # #record(ai, "$(IOC):$(LC):$(LP):DL2ENHIHI_IN") { # field(DESC, "DL2 Energy LOLO") # field(SCAN, "Passive") # field(PINI, "YES") # field(FLNK, "$(IOC):$(LC):$(LP):DL2ENHIHI") # field(VAL, "0") # field(INP, "SIOC:SYS0:ML00:CALC281 CPP MS") # field(EGU, "kG-m") # field(PRIO, "LOW") #} # #record(ai, "$(IOC):$(LC):$(LP):DL2ENLOLO_IN") { # field(DESC, "DL2 Energy LOLO") # field(SCAN, "Passive") # field(PINI, "YES") # field(FLNK, "$(IOC):$(LC):$(LP):DL2ENLOLO") # field(VAL, "0") # field(INP, "SIOC:SYS0:ML00:CALC280 CPP MS") # field(EGU, "kG-m") # field(PRIO, "LOW") #} # LEM PVs used to calculate the DL2 limits record(fanout, "$(IOC):$(LC):$(LP):L3FANOUT") { field(FLNK, "$(IOC):$(LC):$(LP):L3AMP_NOFS") field(LNK1, "$(IOC):$(LC):$(LP):LEM_DL2ENLOLO") field(LNK2, "$(IOC):$(LC):$(LP):LEM_DL2ENHIHI") } record(ao, "$(IOC):$(LC):$(LP):L3AMP_NOFS") { field(DESC, "L3 Amplitude nofb-unfudged") field(SCAN, "Passive") field(VAL, "0") field(DOL, "$(IOC):$(LC):$(LP):L3AMP_NOFS_IN.VAL") field(FLNK, "$(IOC):$(LC):$(LP):L3FANOUT") field(EGU, "MeV") field(OMSL, "closed_loop") field(OIF, "Full") field(DRVH, "15000") field(DRVL, "-3000") field(PRIO, "LOW") } record(ai, "$(IOC):$(LC):$(LP):L3AMP_NOFS_IN") { field(DESC, "L3 Amplitude nofb-unfudged") field(SCAN, "Passive") field(PINI, "YES") field(FLNK, "$(IOC):$(LC):$(LP):L3AMP_NOFS") field(VAL, "0") field(INP, "ACCL:LI25:1:A_NOFS CPP MS") field(EGU, "MeV") field(PRIO, "LOW") } record(fanout, "$(IOC):$(LC):$(LP):S29FANOUT") { field(FLNK, "$(IOC):$(LC):$(LP):S29_ASUM") field(LNK1, "$(IOC):$(LC):$(LP):LEM_DL2ENLOLO") field(LNK2, "$(IOC):$(LC):$(LP):LEM_DL2ENHIHI") } record(ao, "$(IOC):$(LC):$(LP):S29_ASUM") { field(DESC, "S29 Amplitude-unfudged") field(SCAN, "Passive") field(VAL, "0") field(DTYP, "FfConfig") field(OUT, "@S29_ASUM") field(DOL, "$(IOC):$(LC):$(LP):S29_ASUM_IN.VAL") field(FLNK, "$(IOC):$(LC):$(LP):S29FANOUT") field(EGU, "MeV") field(OMSL, "closed_loop") field(OIF, "Full") field(DRVH, "15000") field(DRVL, "-3000") field(PRIO, "LOW") } record(ai, "$(IOC):$(LC):$(LP):S29_ASUM_IN") { field(DESC, "S29 Amplitude-unfudged") field(SCAN, "Passive") field(PINI, "YES") field(FLNK, "$(IOC):$(LC):$(LP):S29_ASUM") field(VAL, "0") field(INP, "ACCL:LI29:0:A_SUM CPP MS") field(EGU, "MeV") field(PRIO, "LOW") } record(fanout, "$(IOC):$(LC):$(LP):S30FANOUT") { field(FLNK, "$(IOC):$(LC):$(LP):S30_ASUM") field(LNK1, "$(IOC):$(LC):$(LP):LEM_DL2ENLOLO") field(LNK2, "$(IOC):$(LC):$(LP):LEM_DL2ENHIHI") } record(ao, "$(IOC):$(LC):$(LP):S30_ASUM") { field(DESC, "S30 AMplitude-unfudged") field(SCAN, "Passive") field(VAL, "0") field(DOL, "$(IOC):$(LC):$(LP):S30_ASUM_IN.VAL") field(FLNK, "$(IOC):$(LC):$(LP):S30FANOUT") field(EGU, "MeV") field(OMSL, "closed_loop") field(OIF, "Full") field(DRVH, "15000") field(DRVL, "-3000") field(PRIO, "LOW") } record(ai, "$(IOC):$(LC):$(LP):S30_ASUM_IN") { field(DESC, "S30 Amplitude-unfudged") field(SCAN, "Passive") field(PINI, "YES") field(FLNK, "$(IOC):$(LC):$(LP):S30_ASUM") field(VAL, "0") field(INP, "ACCL:LI30:0:A_SUM CPP MS") field(EGU, "MeV") field(PRIO, "LOW") } record(calcout, "$(IOC):$(LC):$(LP):LEM_DL2ENLOLO") { field(PINI, "YES") field(INPA, "$(IOC):$(LC):$(LP):L3AMP_NOFS") field(INPB, "$(IOC):$(LC):$(LP):S29_ASUM") field(INPC, "$(IOC):$(LC):$(LP):S30_ASUM") field(DTYP, "FfConfig") field(OUT, "@LEM_DL2ENLOLO") field(EGU, "MeV") field(PREC, "4") field(DESC, "DL2 Low limit from LEM") field(CALC, "A-(B+C)-300") } record(calcout, "$(IOC):$(LC):$(LP):LEM_DL2ENHIHI") { field(PINI, "YES") field(INPA, "$(IOC):$(LC):$(LP):L3AMP_NOFS") field(INPB, "$(IOC):$(LC):$(LP):S29_ASUM") field(INPC, "$(IOC):$(LC):$(LP):S30_ASUM") field(EGU, "MeV") field(DTYP, "FfConfig") field(OUT, "@LEM_DL2ENHIHI") field(PREC, "4") field(DESC, "DL2 High limit from LEM") field(CALC, "A+(B+C)+1000") } #! Further lines contain data used by VisualDCT #! View(2600,1935,1.0) #! Record("$(IOC):$(LC):$(LP):TMITLOW_IN",2100,2126,0,1,"$(IOC):$(LC):$(LP):TMITLOW_IN") #! Field("$(IOC):$(LC):$(LP):TMITLOW_IN.INP",16777215,1,"$(IOC):$(LC):$(LP):TMITLOW_IN.INP") #! Field("$(IOC):$(LC):$(LP):TMITLOW_IN.FLNK",16777215,1,"$(IOC):$(LC):$(LP):TMITLOW_IN.FLNK") #! Link("$(IOC):$(LC):$(LP):TMITLOW_IN.FLNK","$(IOC):$(LC):$(LP):TMITLOW") #! Field("$(IOC):$(LC):$(LP):TMITLOW_IN.VAL",16777215,1,"$(IOC):$(LC):$(LP):TMITLOW_IN.VAL") #! Record("$(IOC):$(LC):$(LP):TMITLOW",2380,2257,0,0,"$(IOC):$(LC):$(LP):TMITLOW") #! Field("$(IOC):$(LC):$(LP):TMITLOW.DOL",16777215,0,"$(IOC):$(LC):$(LP):TMITLOW.DOL") #! Link("$(IOC):$(LC):$(LP):TMITLOW.DOL","$(IOC):$(LC):$(LP):TMITLOW_IN.VAL") #! Record("$(IOC):$(LC):$(LP):BY1BDES_IN",2660,2126,0,1,"$(IOC):$(LC):$(LP):BY1BDES_IN") #! Field("$(IOC):$(LC):$(LP):BY1BDES_IN.FLNK",16777215,1,"$(IOC):$(LC):$(LP):BY1BDES_IN.FLNK") #! Link("$(IOC):$(LC):$(LP):BY1BDES_IN.FLNK","$(IOC):$(LC):$(LP):BY1BDES") #! Field("$(IOC):$(LC):$(LP):BY1BDES_IN.INP",16777215,1,"$(IOC):$(LC):$(LP):BY1BDES_IN.INP") #! Field("$(IOC):$(LC):$(LP):BY1BDES_IN.VAL",16777215,1,"$(IOC):$(LC):$(LP):BY1BDES_IN.VAL") #! Record("$(IOC):$(LC):$(LP):BY1BDES",2940,2257,0,0,"$(IOC):$(LC):$(LP):BY1BDES") #! Field("$(IOC):$(LC):$(LP):BY1BDES.DOL",16777215,0,"$(IOC):$(LC):$(LP):BY1BDES.DOL") #! Link("$(IOC):$(LC):$(LP):BY1BDES.DOL","$(IOC):$(LC):$(LP):BY1BDES_IN.VAL") #! Record("$(IOC):$(LC):$(LP):LI21LVPOS_IN",2080,2546,0,1,"$(IOC):$(LC):$(LP):LI21LVPOS_IN") #! Field("$(IOC):$(LC):$(LP):LI21LVPOS_IN.FLNK",16777215,1,"$(IOC):$(LC):$(LP):LI21LVPOS_IN.FLNK") #! Link("$(IOC):$(LC):$(LP):LI21LVPOS_IN.FLNK","$(IOC):$(LC):$(LP):LI21LVPOS") #! Field("$(IOC):$(LC):$(LP):LI21LVPOS_IN.VAL",16777215,1,"$(IOC):$(LC):$(LP):LI21LVPOS_IN.VAL") #! Field("$(IOC):$(LC):$(LP):LI21LVPOS_IN.INP",16777215,1,"$(IOC):$(LC):$(LP):LI21LVPOS_IN.INP") #! Record("$(IOC):$(LC):$(LP):LI21LVPOS",2360,2677,0,0,"$(IOC):$(LC):$(LP):LI21LVPOS") #! Field("$(IOC):$(LC):$(LP):LI21LVPOS.DOL",16777215,0,"$(IOC):$(LC):$(LP):LI21LVPOS.DOL") #! Link("$(IOC):$(LC):$(LP):LI21LVPOS.DOL","$(IOC):$(LC):$(LP):LI21LVPOS_IN.VAL") #! Record("$(IOC):$(LC):$(LP):LI24LVPOS_IN",2660,2506,0,1,"$(IOC):$(LC):$(LP):LI24LVPOS_IN") #! Field("$(IOC):$(LC):$(LP):LI24LVPOS_IN.FLNK",16777215,1,"$(IOC):$(LC):$(LP):LI24LVPOS_IN.FLNK") #! Link("$(IOC):$(LC):$(LP):LI24LVPOS_IN.FLNK","$(IOC):$(LC):$(LP):LI24LVPOS") #! Field("$(IOC):$(LC):$(LP):LI24LVPOS_IN.VAL",16777215,1,"$(IOC):$(LC):$(LP):LI24LVPOS_IN.VAL") #! Field("$(IOC):$(LC):$(LP):LI24LVPOS_IN.INP",16777215,1,"$(IOC):$(LC):$(LP):LI24LVPOS_IN.INP") #! Record("$(IOC):$(LC):$(LP):LI24LVPOS",2940,2637,0,0,"$(IOC):$(LC):$(LP):LI24LVPOS") #! Field("$(IOC):$(LC):$(LP):LI24LVPOS.DOL",16777215,0,"$(IOC):$(LC):$(LP):LI24LVPOS.DOL") #! Link("$(IOC):$(LC):$(LP):LI24LVPOS.DOL","$(IOC):$(LC):$(LP):LI24LVPOS_IN.VAL") #! Record("$(IOC):$(LC):$(LP):DL2ENLOLO",3400,2357,0,1,"$(IOC):$(LC):$(LP):DL2ENLOLO") #! Field("$(IOC):$(LC):$(LP):DL2ENLOLO.DOL",16777215,0,"$(IOC):$(LC):$(LP):DL2ENLOLO.DOL") #! Link("$(IOC):$(LC):$(LP):DL2ENLOLO.DOL","$(IOC):$(LC):$(LP):DL2ENLOLO_IN.VAL") #! Record("$(IOC):$(LC):$(LP):DL2ENHIHI",3900,2357,0,1,"$(IOC):$(LC):$(LP):DL2ENHIHI") #! Field("$(IOC):$(LC):$(LP):DL2ENHIHI.DOL",16777215,0,"$(IOC):$(LC):$(LP):DL2ENHIHI.DOL") #! Link("$(IOC):$(LC):$(LP):DL2ENHIHI.DOL","$(IOC):$(LC):$(LP):DL2ENHIHI_IN.VAL") #! Record("$(IOC):$(LC):$(LP):DL2ENHIHI_IN",3660,2126,0,1,"$(IOC):$(LC):$(LP):DL2ENHIHI_IN") #! Field("$(IOC):$(LC):$(LP):DL2ENHIHI_IN.FLNK",16777215,1,"$(IOC):$(LC):$(LP):DL2ENHIHI_IN.FLNK") #! Link("$(IOC):$(LC):$(LP):DL2ENHIHI_IN.FLNK","$(IOC):$(LC):$(LP):DL2ENHIHI") #! Field("$(IOC):$(LC):$(LP):DL2ENHIHI_IN.INP",16777215,1,"$(IOC):$(LC):$(LP):DL2ENHIHI_IN.INP") #! Field("$(IOC):$(LC):$(LP):DL2ENHIHI_IN.VAL",16777215,0,"$(IOC):$(LC):$(LP):DL2ENHIHI_IN.VAL") #! Record("$(IOC):$(LC):$(LP):DL2ENLOLO_IN",3160,2126,0,1,"$(IOC):$(LC):$(LP):DL2ENLOLO_IN") #! Field("$(IOC):$(LC):$(LP):DL2ENLOLO_IN.INP",16777215,1,"$(IOC):$(LC):$(LP):DL2ENLOLO_IN.INP") #! Field("$(IOC):$(LC):$(LP):DL2ENLOLO_IN.FLNK",16777215,1,"$(IOC):$(LC):$(LP):DL2ENLOLO_IN.FLNK") #! Link("$(IOC):$(LC):$(LP):DL2ENLOLO_IN.FLNK","$(IOC):$(LC):$(LP):DL2ENLOLO") #! Field("$(IOC):$(LC):$(LP):DL2ENLOLO_IN.VAL",16777215,0,"$(IOC):$(LC):$(LP):DL2ENLOLO_IN.VAL")