#! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(mbbiDirect, "PLC:CP08:CR01:CCAlarmL") { field(DESC, "PLC card fault latches") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) Cryocon_AlarmLatch B 0") field(NOBT, "16") field(PINI, "YES") }F record(bo, "PLC:CP08:CR01:CCBYPASS_B0") { field(DESC, "Cryocon bypass 0") field(SCAN, "Passive") field(DTYP, "EtherIP")F field(OUT, "@$(PLC_NAME) Cryocon_Byp B 0") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(bo, "PLC:CP08:CR01:CCBYPASS_B1") { field(DESC, "Cryocon fault bypass 1") field(SCAN, "Passive") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) Cryocon_Byp B 1") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(bo, "PLC:CP08:CR01:CCBYPASS_B2") { field(DESC, "Cryocon fault bypass 2") field(SCAN, "Passive") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) Cryocon_Byp B 2") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(bi, "PLC:CP08:CR01:CCALARM") { field(DESC, "Cryocon total Alarm") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) Cryocon_Alarm") field(ZNAM, "OK") field(ONAM, "FAULT") field(PINI, "YES") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:CP08:CR01:CC2FAILED") { field(DESC, "cryocon 2 failed") field(SCAN, "2 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) Cryocon2.Failed") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") field(ZNAM, "OK") field(ONAM, "FAULT") } record(bi, "PLC:CP08:CR01:CC1FAILED") { field(DESC, "cryocon 1 failed") field(SCAN, "2 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) Cryocon1.Failed") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") field(ZNAM, "OK") field(ONAM, "FAULT") } record(bi, "PLC:CP08:CR01:CC3FAILED") { field(DESC, "cryocon 3 failed") field(SCAN, "2 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) Cryocon3.Failed") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") field(ZNAM, "OK") field(ONAM, "FAULT") } record(bi, "PLC:CP08:CR01:CC4FAILED") { field(DESC, "cryocon 4 failed") field(SCAN, "2 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) Cryocon4.Failed") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") field(ZNAM, "OK") field(ONAM, "FAULT") } record(bi, "PLC:CP08:CR01:CC5FAILED") { field(DESC, "cryocon 5 failed") field(SCAN, "2 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) Cryocon5.Failed") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") field(ZNAM, "OK") field(ONAM, "FAULT") } record(bi, "PLC:CP08:CR01:CC6FAILED") { field(DESC, "cryocon 6 failed") field(SCAN, "2 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) Cryocon6.Failed") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") field(ZNAM, "OK") field(ONAM, "FAULT") } record(bo, "PLC:CP08:CR01:CCBYPASS_B3") { field(DESC, "Cryocon fault bypass 3") field(SCAN, "Passive") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) Cryocon_Byp B 3") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(bo, "PLC:CP08:CR01:CCBYPASS_B4") { field(DESC, "Cryocon fault bypass 4") field(SCAN, "Passive") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) Cryocon_Byp B 4") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(bo, "PLC:CP08:CR01:CCBYPASS_B5") { field(DESC, "Cryocon fault bypass 5") field(SCAN, "Passive") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) Cryocon_Byp B 5") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(bo, "PLC:CP08:CR01:CCBYPASS_B6") { field(DESC, "Cryocon fault bypass 6") field(SCAN, "Passive") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) Cryocon_Byp B 6") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(mbbiDirect, "PLC:CP08:CR01:Alarm1") { field(DESC, "PLC card faults") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PLC_Alarm[1] B 0") field(NOBT, "16") field(PINI, "YES") } record(bi, "PLC:CP08:CR01:ALARM1_B0") { field(DESC, "ENet Alarm1 B0") field(SCAN, "2 second") field(DTYP, "Soft Channel") field(INP, "PLC:CP08:CR01:Alarm1.B0") field(ZNAM, "OK") field(ONAM, "FAULT") field(PINI, "YES") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:CP08:CR01:ALARM1_B1") { field(DESC, "R2S1 ALARM B1") field(SCAN, "2 second") field(DTYP, "Soft Channel") field(INP, "PLC:CP08:CR01:Alarm1.B1") field(ZNAM, "OK") field(ONAM, "FAULT") field(PINI, "YES") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:CP08:CR01:ALARM1_B2") { field(DESC, "R2S2 ALARM B2") field(SCAN, "2 second") field(DTYP, "Soft Channel") field(INP, "PLC:CP08:CR01:Alarm1.B2") field(ZNAM, "OK") field(ONAM, "FAULT") field(PINI, "YES") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:CP08:CR01:ALARM1_B3") { field(DESC, "R2S3 ALARM B3") field(SCAN, "2 second") field(DTYP, "Soft Channel") field(INP, "PLC:CP08:CR01:Alarm1.B3") field(ZNAM, "OK") field(ONAM, "FAULT") field(PINI, "YES") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:CP08:CR01:ALARM1_B4") { field(DESC, "R2S4 ALARM B4") field(SCAN, "2 second") field(DTYP, "Soft Channel") field(INP, "PLC:CP08:CR01:Alarm1.B4") field(ZNAM, "OK") field(ONAM, "FAULT") field(PINI, "YES") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:CP08:CR01:ALARM1_B5") { field(DESC, "R2S5ALARM B5") field(SCAN, "2 second") field(DTYP, "Soft Channel") field(INP, "PLC:CP08:CR01:Alarm1.B5") field(ZNAM, "OK") field(ONAM, "FAULT") field(PINI, "YES") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:CP08:CR01:ALARM1_B6") { field(DESC, "R2S6 ALARM B6") field(SCAN, "2 second") field(DTYP, "Soft Channel") field(INP, "PLC:CP08:CR01:Alarm1.B6") field(ZNAM, "OK") field(ONAM, "FAULT") field(PINI, "YES") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:CP08:CR01:ALARM1_B7") { field(DESC, "R2S7 ALARM B7") field(SCAN, "2 second") field(DTYP, "Soft Channel") field(INP, "PLC:CP08:CR01:Alarm1.B7") field(ZNAM, "OK") field(ONAM, "FAULT") field(PINI, "YES") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:CP08:CR01:ALARM1_B8") { field(DESC, "R2S8 ALARM B8") field(SCAN, "2 second") field(DTYP, "Soft Channel") field(INP, "PLC:CP08:CR01:Alarm1.B8") field(ZNAM, "OK") field(ONAM, "FAULT") field(PINI, "YES") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(mbbiDirect, "PLC:CP08:CR01:AlarmL1") { field(DESC, "PLC card fault latches") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) PLC_AlarmL[1] B 0") field(NOBT, "16") field(PINI, "YES") } record(mbbiDirect, "PLC:CP08:CR01:CH_R2S1FAULTS") { field(DESC, "PLC card channel faults") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) ChannelFaults[18] B 0") field(NOBT, "16") field(PINI, "YES") } record(mbbiDirect, "PLC:CP08:CR01:CH_R2S2FAULTS") { field(DESC, "PLC card channel faults") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) ChannelFaults[19] B 0") field(NOBT, "16") field(PINI, "YES") } record(mbbiDirect, "PLC:CP08:CR01:CH_R2S3FAULTS") { field(DESC, "PLC card channel faults") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) ChannelFaults[20] B 0") field(NOBT, "16") field(PINI, "YES") } record(mbbiDirect, "PLC:CP08:CR01:CH_R2S4FAULTS") { field(DESC, "PLC card channel faults") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) ChannelFaults[21] B 0") field(NOBT, "16") field(PINI, "YES") } record(mbbiDirect, "PLC:CP08:CR01:CH_R2S5FAULTS") { field(DESC, "PLC card channel faults") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) ChannelFaults[22] B 0") field(NOBT, "16") field(PINI, "YES") } record(mbbiDirect, "PLC:CP08:CR01:CH_R2S6FAULTS") { field(DESC, "PLC card channel faults") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) ChannelFaults[23] B 0") field(NOBT, "16") field(PINI, "YES") } record(mbbiDirect, "PLC:CP08:CR01:CH_R2S7FAULTS") { field(DESC, "PLC card channel faults") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) ChannelFaults[24] B 0") field(NOBT, "16") field(PINI, "YES") } record(mbbiDirect, "PLC:CP08:CR01:CH_R2S8FAULTS") { field(DESC, "PLC card channel faults") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) ChannelFaults[25] B 0") field(NOBT, "16") field(PINI, "YES") } record(bo, "PLC:CP08:CR01:BYPASS1_B0") { field(DESC, "Enet Card fault bypass") field(SCAN, "Passive") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 0") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(bo, "PLC:CP08:CR01:BYPASS1_B1") { field(DESC, "R2S1 card fault bypass") field(SCAN, "Passive") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 1") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(bo, "PLC:CP08:CR01:BYPASS1_B2") { field(DESC, "R2S2 card fault bypass") field(SCAN, "Passive") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 2") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(bo, "PLC:CP08:CR01:BYPASS1_B3") { field(DESC, "R2S3 card fault bypass") field(SCAN, "Passive") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 3") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(bo, "PLC:CP08:CR01:BYPASS1_B4") { field(DESC, "R2S4 card fault bypass") field(SCAN, "Passive") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 4") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(bo, "PLC:CP08:CR01:BYPASS1_B5") { field(DESC, "R2S5 card fault bypass") field(SCAN, "Passive") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 5") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(bo, "PLC:CP08:CR01:BYPASS1_B6") { field(DESC, "R2S6 card fault bypass") field(SCAN, "Passive") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 6") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(bo, "PLC:CP08:CR01:BYPASS1_B7") { field(DESC, "R2S7 card fault bypass") field(SCAN, "Passive") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 7") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(bo, "PLC:CP08:CR01:BYPASS1_B8") { field(DESC, "R2S8 card fault bypass") field(SCAN, "Passive") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 8") field(ZNAM, "ACT") field(ONAM, "BYP") field(ASG, "CRYO") field(PINI, "NO") field(HIGH, "0") } record(mbbiDirect, "PLC:CP08:CR01:CH_FAULTS11") { field(DESC, "PLC card channel faults") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) ChannelFaults[11] B 0") field(NOBT, "16") field(PINI, "YES") } record(mbbiDirect, "PLC:CP08:CR01:CH_FAULTS12") { field(DESC, "PLC card channel faults") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) ChannelFaults[12] B 0") field(NOBT, "16") field(PINI, "YES") } record(mbbiDirect, "PLC:CP08:CR01:CH_FAULTS13") { field(DESC, "PLC card channel faults") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) ChannelFaults[13] B 0") field(NOBT, "16") field(PINI, "YES") } record(mbbiDirect, "PLC:CP08:CR01:CH_FAULTS14") { field(DESC, "PLC card channel faults") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) ChannelFaults[14] B 0") field(NOBT, "16") field(PINI, "YES") } record(mbbiDirect, "PLC:CP08:CR01:CH_FAULTS10") { field(DESC, "PLC card channel faults") field(SCAN, "2 second") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) ChannelFaults[10] B 0") field(NOBT, "16") field(PINI, "YES") } #! Further lines contain data used by VisualDCT #! View(0,273,1.0) #! Record("PLC:CP08:CR01:CCAlarmL",160,1280,0,1,"PLC:CP08:CR01:CCAlarmL") #! Record("PLC:CP08:CR01:CCBYPASS_B0",160,1079,0,1,"PLC:CP08:CR01:CCBYPASS_B0") #! Record("PLC:CP08:CR01:CCBYPASS_B1",360,1079,0,1,"PLC:CP08:CR01:CCBYPASS_B1") #! Record("PLC:CP08:CR01:CCBYPASS_B2",560,1079,0,1,"PLC:CP08:CR01:CCBYPASS_B2") #! Record("PLC:CP08:CR01:CCALARM",160,859,0,1,"PLC:CP08:CR01:CCALARM") #! Record("PLC:CP08:CR01:CC2FAILED",560,859,0,1,"PLC:CP08:CR01:CC2FAILED") #! Record("PLC:CP08:CR01:CC1FAILED",360,859,0,1,"PLC:CP08:CR01:CC1FAILED") #! Record("PLC:CP08:CR01:CC3FAILED",761,859,0,1,"PLC:CP08:CR01:CC3FAILED") #! Record("PLC:CP08:CR01:CC4FAILED",961,859,0,1,"PLC:CP08:CR01:CC4FAILED") #! Record("PLC:CP08:CR01:CC5FAILED",1160,859,0,1,"PLC:CP08:CR01:CC5FAILED") #! Record("PLC:CP08:CR01:CC6FAILED",1360,859,0,1,"PLC:CP08:CR01:CC6FAILED") #! Record("PLC:CP08:CR01:CCBYPASS_B3",762,1079,0,1,"PLC:CP08:CR01:CCBYPASS_B3") #! Record("PLC:CP08:CR01:CCBYPASS_B4",962,1079,0,1,"PLC:CP08:CR01:CCBYPASS_B4") #! Record("PLC:CP08:CR01:CCBYPASS_B5",1160,1079,0,1,"PLC:CP08:CR01:CCBYPASS_B5") #! Record("PLC:CP08:CR01:CCBYPASS_B6",1360,1079,0,1,"PLC:CP08:CR01:CCBYPASS_B6") #! Record("PLC:CP08:CR01:Alarm1",100,2160,0,1,"PLC:CP08:CR01:Alarm1") #! Field("PLC:CP08:CR01:Alarm1.B0",16777215,0,"PLC:CP08:CR01:Alarm1.B0") #! Field("PLC:CP08:CR01:Alarm1.B1",16777215,1,"PLC:CP08:CR01:Alarm1.B1") #! Field("PLC:CP08:CR01:Alarm1.B2",16777215,1,"PLC:CP08:CR01:Alarm1.B2") #! Field("PLC:CP08:CR01:Alarm1.B3",16777215,1,"PLC:CP08:CR01:Alarm1.B3") #! Field("PLC:CP08:CR01:Alarm1.B4",16777215,1,"PLC:CP08:CR01:Alarm1.B4") #! Field("PLC:CP08:CR01:Alarm1.B5",16777215,1,"PLC:CP08:CR01:Alarm1.B5") #! Field("PLC:CP08:CR01:Alarm1.B6",16777215,1,"PLC:CP08:CR01:Alarm1.B6") #! Field("PLC:CP08:CR01:Alarm1.B7",16777215,1,"PLC:CP08:CR01:Alarm1.B7") #! Field("PLC:CP08:CR01:Alarm1.B8",16777215,0,"PLC:CP08:CR01:Alarm1.B8") #! Record("PLC:CP08:CR01:ALARM1_B0",340,2079,0,1,"PLC:CP08:CR01:ALARM1_B0") #! Field("PLC:CP08:CR01:ALARM1_B0.INP",16777215,0,"PLC:CP08:CR01:ALARM1_B0.INP") #! Link("PLC:CP08:CR01:ALARM1_B0.INP","PLC:CP08:CR01:Alarm1.B0") #! Record("PLC:CP08:CR01:ALARM1_B1",520,2079,0,1,"PLC:CP08:CR01:ALARM1_B1") #! Field("PLC:CP08:CR01:ALARM1_B1.INP",16777215,0,"PLC:CP08:CR01:ALARM1_B1.INP") #! Link("PLC:CP08:CR01:ALARM1_B1.INP","PLC:CP08:CR01:Alarm1.B1") #! Record("PLC:CP08:CR01:ALARM1_B2",700,2079,0,1,"PLC:CP08:CR01:ALARM1_B2") #! Field("PLC:CP08:CR01:ALARM1_B2.INP",16777215,0,"PLC:CP08:CR01:ALARM1_B2.INP") #! Link("PLC:CP08:CR01:ALARM1_B2.INP","PLC:CP08:CR01:Alarm1.B2") #! Record("PLC:CP08:CR01:ALARM1_B3",880,2079,0,1,"PLC:CP08:CR01:ALARM1_B3") #! Field("PLC:CP08:CR01:ALARM1_B3.INP",16777215,0,"PLC:CP08:CR01:ALARM1_B3.INP") #! Link("PLC:CP08:CR01:ALARM1_B3.INP","PLC:CP08:CR01:Alarm1.B3") #! Record("PLC:CP08:CR01:ALARM1_B4",1060,2079,0,1,"PLC:CP08:CR01:ALARM1_B4") #! Field("PLC:CP08:CR01:ALARM1_B4.INP",16777215,0,"PLC:CP08:CR01:ALARM1_B4.INP") #! Link("PLC:CP08:CR01:ALARM1_B4.INP","PLC:CP08:CR01:Alarm1.B4") #! Record("PLC:CP08:CR01:ALARM1_B5",1240,2079,0,1,"PLC:CP08:CR01:ALARM1_B5") #! Field("PLC:CP08:CR01:ALARM1_B5.INP",16777215,0,"PLC:CP08:CR01:ALARM1_B5.INP") #! Link("PLC:CP08:CR01:ALARM1_B5.INP","PLC:CP08:CR01:Alarm1.B5") #! Record("PLC:CP08:CR01:ALARM1_B6",1420,2079,0,1,"PLC:CP08:CR01:ALARM1_B6") #! Field("PLC:CP08:CR01:ALARM1_B6.INP",16777215,0,"PLC:CP08:CR01:ALARM1_B6.INP") #! Link("PLC:CP08:CR01:ALARM1_B6.INP","PLC:CP08:CR01:Alarm1.B6") #! Record("PLC:CP08:CR01:ALARM1_B7",1600,2079,0,1,"PLC:CP08:CR01:ALARM1_B7") #! Field("PLC:CP08:CR01:ALARM1_B7.INP",16777215,0,"PLC:CP08:CR01:ALARM1_B7.INP") #! Link("PLC:CP08:CR01:ALARM1_B7.INP","PLC:CP08:CR01:Alarm1.B7") #! Record("PLC:CP08:CR01:ALARM1_B8",360,2319,0,1,"PLC:CP08:CR01:ALARM1_B8") #! Field("PLC:CP08:CR01:ALARM1_B8.INP",16777215,0,"PLC:CP08:CR01:ALARM1_B8.INP") #! Link("PLC:CP08:CR01:ALARM1_B8.INP","PLC:CP08:CR01:Alarm1.B8") #! Record("PLC:CP08:CR01:AlarmL1",440,1860,0,1,"PLC:CP08:CR01:AlarmL1") #! Record("PLC:CP08:CR01:CH_R2S1FAULTS",140,600,0,1,"PLC:CP08:CR01:CH_R2S1FAULTS") #! Record("PLC:CP08:CR01:CH_R2S2FAULTS",320,600,0,1,"PLC:CP08:CR01:CH_R2S2FAULTS") #! Record("PLC:CP08:CR01:CH_R2S3FAULTS",500,600,0,1,"PLC:CP08:CR01:CH_R2S3FAULTS") #! Record("PLC:CP08:CR01:CH_R2S4FAULTS",680,600,0,1,"PLC:CP08:CR01:CH_R2S4FAULTS") #! Record("PLC:CP08:CR01:CH_R2S5FAULTS",860,600,0,1,"PLC:CP08:CR01:CH_R2S5FAULTS") #! Record("PLC:CP08:CR01:CH_R2S6FAULTS",1040,600,0,1,"PLC:CP08:CR01:CH_R2S6FAULTS") #! Record("PLC:CP08:CR01:CH_R2S7FAULTS",1220,600,0,1,"PLC:CP08:CR01:CH_R2S7FAULTS") #! Record("PLC:CP08:CR01:CH_R2S8FAULTS",1400,600,0,1,"PLC:CP08:CR01:CH_R2S8FAULTS") #! Record("PLC:CP08:CR01:BYPASS1_B0",80,1619,0,1,"PLC:CP08:CR01:BYPASS1_B0") #! Record("PLC:CP08:CR01:BYPASS1_B1",260,1619,0,1,"PLC:CP08:CR01:BYPASS1_B1") #! Record("PLC:CP08:CR01:BYPASS1_B2",440,1619,0,1,"PLC:CP08:CR01:BYPASS1_B2") #! Record("PLC:CP08:CR01:BYPASS1_B3",620,1619,0,1,"PLC:CP08:CR01:BYPASS1_B3") #! Record("PLC:CP08:CR01:BYPASS1_B4",800,1619,0,1,"PLC:CP08:CR01:BYPASS1_B4") #! Record("PLC:CP08:CR01:BYPASS1_B5",980,1619,0,1,"PLC:CP08:CR01:BYPASS1_B5") #! Record("PLC:CP08:CR01:BYPASS1_B6",1160,1619,0,1,"PLC:CP08:CR01:BYPASS1_B6") #! Record("PLC:CP08:CR01:BYPASS1_B7",1340,1619,0,1,"PLC:CP08:CR01:BYPASS1_B7") #! Record("PLC:CP08:CR01:BYPASS1_B8",1520,1619,0,1,"PLC:CP08:CR01:BYPASS1_B8") #! Record("PLC:CP08:CR01:CH_FAULTS11",460,380,0,1,"PLC:CP08:CR01:CH_FAULTS11") #! Record("PLC:CP08:CR01:CH_FAULTS12",640,380,0,1,"PLC:CP08:CR01:CH_FAULTS12") #! Record("PLC:CP08:CR01:CH_FAULTS13",820,380,0,1,"PLC:CP08:CR01:CH_FAULTS13") #! Record("PLC:CP08:CR01:CH_FAULTS14",1000,380,0,1,"PLC:CP08:CR01:CH_FAULTS14") #! Record("PLC:CP08:CR01:CH_FAULTS10",280,380,0,1,"PLC:CP08:CR01:CH_FAULTS10") #! TextBox(TB0,1840,1900,1960,1900,0,"Dialog",12,1,16777215,"Latches for Alarm1",null) #! TextBox(TB7,340,280,880,320,0,"Dialog",12,1,16777215,"CH_FAULTS1 MBBI word - PLC Card Channel Faults\n - additional needed by utility PLC for R1 Slots 10 - 14\n",null) #! TextBox(TB6,221,559,761,599,0,"Dialog",12,1,16777215,"CH_FAULTS1 MBBI word - PLC Card Channel Faults\n - only those additional needed by utility PLC for rack 2\n",null) #! TextBox(TB5,420,1820,900,1860,0,"Dialog",12,1,16777215,"Alarm Latch 1 - Additional alarm latches for Utilities PLC, Rack 2 Slots\n",null) #! TextBox(TB4,520,2040,1000,2080,0,"Dialog",12,1,16777215,"Alarm 1 - Additional fault alarms for Utilities PLC, Rack 2 Slots\n",null) #! TextBox(TB3,580,1540,1060,1580,0,"Dialog",12,1,16777215,"Alarm Bypasses - Additional for Utilities PLC\n",null) #! TextBox(TB2,160,800,640,840,0,"Dialog",12,1,16777215,"Cryocon Alarms, Bypasses, Latches - 6 Cryocons\n",null)