#! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP07:1010:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP07:1010:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP07:1010:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP07:1010:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP07:1010:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:SP_RQST") { field(DESC, "CPIC71010 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP07:1010:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "CPIC71010") } record(ao, "CPIC:CP07:1010:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP07:1010:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP07:1010:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP07:1010:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP07:1010:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP07:1010:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010_OVH.Mode_Status") } record(bi, "CPIC:CP07:1010:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP07:1010:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP07:1010:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP07:1010:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP07:1010:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP07:1010:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010_OVH.Mode_String") } record(bi, "CPIC:CP07:1010:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP07:1010:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP07:1010:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "CPV71010") } record(ai, "CPIC:CP07:1010:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP07:1010:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP07:1010:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.MODE") } record(bo, "CPIC:CP07:1010:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71010_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP07:1010:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71010_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP07:1010:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71010_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP07:1010:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP07:1010:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71010.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP07:1010:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP07:1010:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP07:1010:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP07:1010:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP07:1010:ORBV",2100,2312,0,1,"CPIC:CP07:1010:ORBV") #! Record("CPIC:CP07:1010:OVAL",2280,2312,0,1,"CPIC:CP07:1010:OVAL") #! Record("CPIC:CP07:1010:CVAL",2460,2312,0,1,"CPIC:CP07:1010:CVAL") #! Record("CPIC:CP07:1010:MAX",2122,1932,0,1,"CPIC:CP07:1010:MAX") #! Record("CPIC:CP07:1010:DMIN",2300,1932,0,1,"CPIC:CP07:1010:DMIN") #! Record("CPIC:CP07:1010:DMAX",2479,1932,0,1,"CPIC:CP07:1010:DMAX") #! Record("CPIC:CP07:1010:MDT",2120,2112,0,1,"CPIC:CP07:1010:MDT") #! Record("CPIC:CP07:1010:KP",2300,2106,0,1,"CPIC:CP07:1010:KP") #! Record("CPIC:CP07:1010:KI",2480,2106,0,1,"CPIC:CP07:1010:KI") #! Record("CPIC:CP07:1010:KD",2660,2106,0,1,"CPIC:CP07:1010:KD") #! Record("CPIC:CP07:1010:S",2840,2120,0,1,"CPIC:CP07:1010:S") #! Record("CPIC:CP07:1010:SP_RQST",1760,1932,0,1,"CPIC:CP07:1010:SP_RQST") #! Record("CPIC:CP07:1010:MIN",1945,1932,0,1,"CPIC:CP07:1010:MIN") #! Record("CPIC:CP07:1010:PIDTAG",1740,2462,0,1,"CPIC:CP07:1010:PIDTAG") #! Record("CPIC:CP07:1010:PEVAL",2660,1932,0,1,"CPIC:CP07:1010:PEVAL") #! Record("CPIC:CP07:1010:FSB",2840,1932,0,1,"CPIC:CP07:1010:FSB") #! Record("CPIC:CP07:1010:NOMATCH",3180,2499,0,1,"CPIC:CP07:1010:NOMATCH") #! Record("CPIC:CP07:1010:CHFAULT",3000,2506,0,1,"CPIC:CP07:1010:CHFAULT") #! Record("CPIC:CP07:1010:MANPOS_RQST",1940,2112,0,1,"CPIC:CP07:1010:MANPOS_RQST") #! Record("CPIC:CP07:1010:MODE_STATUS",1920,2314,0,1,"CPIC:CP07:1010:MODE_STATUS") #! Record("CPIC:CP07:1010:INTERLOCK",2460,2499,0,0,"CPIC:CP07:1010:INTERLOCK") #! Record("CPIC:CP07:1010:IVAL",2641,2312,0,1,"CPIC:CP07:1010:IVAL") #! Record("CPIC:CP07:1010:SVAL",2820,2312,0,1,"CPIC:CP07:1010:SVAL") #! Record("CPIC:CP07:1010:MMOD",2100,2506,0,1,"CPIC:CP07:1010:MMOD") #! Record("CPIC:CP07:1010:SMOD",2282,2506,0,1,"CPIC:CP07:1010:SMOD") #! Record("CPIC:CP07:1010:MODE_STRING",1740,2314,0,1,"CPIC:CP07:1010:MODE_STRING") #! Record("CPIC:CP07:1010:PMOD",1922,2479,0,1,"CPIC:CP07:1010:PMOD") #! Record("CPIC:CP07:1010:IMOD",2640,2499,0,1,"CPIC:CP07:1010:IMOD") #! Record("CPIC:CP07:1010:ACTUATOR",1740,2582,0,1,"CPIC:CP07:1010:ACTUATOR") #! Record("CPIC:CP07:1010:AVAL",3000,2312,0,1,"CPIC:CP07:1010:AVAL") #! Record("CPIC:CP07:1010:AMOD",2824,2506,0,1,"CPIC:CP07:1010:AMOD") #! Record("CPIC:CP07:1010:MODE",1760,2134,0,1,"CPIC:CP07:1010:MODE") #! Record("CPIC:CP07:1010:MANUAL",1951,2719,0,1,"CPIC:CP07:1010:MANUAL") #! Record("CPIC:CP07:1010:SEQUENCER",2140,2719,0,1,"CPIC:CP07:1010:SEQUENCER") #! Record("CPIC:CP07:1010:AUTO",2320,2719,0,1,"CPIC:CP07:1010:AUTO") #! Record("CPIC:CP07:1010:IL_LATCH",2680,2699,0,1,"CPIC:CP07:1010:IL_LATCH") #! Record("CPIC:CP07:1010:IL_RESET",2502,2719,0,1,"CPIC:CP07:1010:IL_RESET") #! Record("CPIC:CP07:1010:MVAL",3175,2312,0,1,"CPIC:CP07:1010:MVAL") #! Record("CPIC:CP07:1010:PVAL",3360,2312,0,1,"CPIC:CP07:1010:PVAL") #! Record("CPIC:CP07:1010:CMD_OUT",3042,1932,0,1,"CPIC:CP07:1010:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP07 cryoplant number and area in cryoplant\n1010 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP07:1010:TEXT1",1739,2702,0,1,"CPIC:CP07:1010:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP07:1020:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP07:1020:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP07:1020:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP07:1020:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP07:1020:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:SP_RQST") { field(DESC, "CPIC71020 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP07:1020:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "CPIC71020") } record(ao, "CPIC:CP07:1020:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP07:1020:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP07:1020:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP07:1020:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP07:1020:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP07:1020:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020_OVH.Mode_Status") } record(bi, "CPIC:CP07:1020:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP07:1020:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP07:1020:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP07:1020:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP07:1020:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP07:1020:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020_OVH.Mode_String") } record(bi, "CPIC:CP07:1020:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP07:1020:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP07:1020:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "CPV71020") } record(ai, "CPIC:CP07:1020:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP07:1020:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP07:1020:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.MODE") } record(bo, "CPIC:CP07:1020:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71020_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP07:1020:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71020_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP07:1020:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71020_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP07:1020:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP07:1020:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71020.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP07:1020:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP07:1020:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP07:1020:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP07:1020:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP07:1020:ORBV",2100,2312,0,1,"CPIC:CP07:1020:ORBV") #! Record("CPIC:CP07:1020:OVAL",2280,2312,0,1,"CPIC:CP07:1020:OVAL") #! Record("CPIC:CP07:1020:CVAL",2460,2312,0,1,"CPIC:CP07:1020:CVAL") #! Record("CPIC:CP07:1020:MAX",2122,1932,0,1,"CPIC:CP07:1020:MAX") #! Record("CPIC:CP07:1020:DMIN",2300,1932,0,1,"CPIC:CP07:1020:DMIN") #! Record("CPIC:CP07:1020:DMAX",2479,1932,0,1,"CPIC:CP07:1020:DMAX") #! Record("CPIC:CP07:1020:MDT",2120,2112,0,1,"CPIC:CP07:1020:MDT") #! Record("CPIC:CP07:1020:KP",2300,2106,0,1,"CPIC:CP07:1020:KP") #! Record("CPIC:CP07:1020:KI",2480,2106,0,1,"CPIC:CP07:1020:KI") #! Record("CPIC:CP07:1020:KD",2660,2106,0,1,"CPIC:CP07:1020:KD") #! Record("CPIC:CP07:1020:S",2840,2120,0,1,"CPIC:CP07:1020:S") #! Record("CPIC:CP07:1020:SP_RQST",1760,1932,0,1,"CPIC:CP07:1020:SP_RQST") #! Record("CPIC:CP07:1020:MIN",1945,1932,0,1,"CPIC:CP07:1020:MIN") #! Record("CPIC:CP07:1020:PIDTAG",1740,2462,0,1,"CPIC:CP07:1020:PIDTAG") #! Record("CPIC:CP07:1020:PEVAL",2660,1932,0,1,"CPIC:CP07:1020:PEVAL") #! Record("CPIC:CP07:1020:FSB",2840,1932,0,1,"CPIC:CP07:1020:FSB") #! Record("CPIC:CP07:1020:NOMATCH",3180,2499,0,1,"CPIC:CP07:1020:NOMATCH") #! Record("CPIC:CP07:1020:CHFAULT",3000,2506,0,1,"CPIC:CP07:1020:CHFAULT") #! Record("CPIC:CP07:1020:MANPOS_RQST",1940,2112,0,1,"CPIC:CP07:1020:MANPOS_RQST") #! Record("CPIC:CP07:1020:MODE_STATUS",1920,2314,0,1,"CPIC:CP07:1020:MODE_STATUS") #! Record("CPIC:CP07:1020:INTERLOCK",2460,2499,0,0,"CPIC:CP07:1020:INTERLOCK") #! Record("CPIC:CP07:1020:IVAL",2641,2312,0,1,"CPIC:CP07:1020:IVAL") #! Record("CPIC:CP07:1020:SVAL",2820,2312,0,1,"CPIC:CP07:1020:SVAL") #! Record("CPIC:CP07:1020:MMOD",2100,2506,0,1,"CPIC:CP07:1020:MMOD") #! Record("CPIC:CP07:1020:SMOD",2282,2506,0,1,"CPIC:CP07:1020:SMOD") #! Record("CPIC:CP07:1020:MODE_STRING",1740,2314,0,1,"CPIC:CP07:1020:MODE_STRING") #! Record("CPIC:CP07:1020:PMOD",1922,2479,0,1,"CPIC:CP07:1020:PMOD") #! Record("CPIC:CP07:1020:IMOD",2640,2499,0,1,"CPIC:CP07:1020:IMOD") #! Record("CPIC:CP07:1020:ACTUATOR",1740,2582,0,1,"CPIC:CP07:1020:ACTUATOR") #! Record("CPIC:CP07:1020:AVAL",3000,2312,0,1,"CPIC:CP07:1020:AVAL") #! Record("CPIC:CP07:1020:AMOD",2824,2506,0,1,"CPIC:CP07:1020:AMOD") #! Record("CPIC:CP07:1020:MODE",1760,2134,0,1,"CPIC:CP07:1020:MODE") #! Record("CPIC:CP07:1020:MANUAL",1951,2719,0,1,"CPIC:CP07:1020:MANUAL") #! Record("CPIC:CP07:1020:SEQUENCER",2140,2719,0,1,"CPIC:CP07:1020:SEQUENCER") #! Record("CPIC:CP07:1020:AUTO",2320,2719,0,1,"CPIC:CP07:1020:AUTO") #! Record("CPIC:CP07:1020:IL_LATCH",2680,2699,0,1,"CPIC:CP07:1020:IL_LATCH") #! Record("CPIC:CP07:1020:IL_RESET",2502,2719,0,1,"CPIC:CP07:1020:IL_RESET") #! Record("CPIC:CP07:1020:MVAL",3175,2312,0,1,"CPIC:CP07:1020:MVAL") #! Record("CPIC:CP07:1020:PVAL",3360,2312,0,1,"CPIC:CP07:1020:PVAL") #! Record("CPIC:CP07:1020:CMD_OUT",3042,1932,0,1,"CPIC:CP07:1020:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP07 cryoplant number and area in cryoplant\n1020 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP07:1020:TEXT1",1739,2702,0,1,"CPIC:CP07:1020:TEXT1")