record(mbbiDirect, "PLC:$(AREA):$(LOCA):CCAlarmL") {
  field(DESC, "PLC card fault latches")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) Cryocon_AlarmLatch B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}F

record(bo, "PLC:$(AREA):$(LOCA):CCBYPASS_B0") {
  field(DESC, "Cryocon bypass 0")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")F
  field(OUT, "@$(PLC_NAME) Cryocon_Byp B 0")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}

record(bo, "PLC:$(AREA):$(LOCA):CCBYPASS_B1") {
  field(DESC, "Cryocon fault bypass 1")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) Cryocon_Byp B 1")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}

record(bo, "PLC:$(AREA):$(LOCA):CCBYPASS_B2") {
  field(DESC, "Cryocon fault bypass 2")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) Cryocon_Byp B 2")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}

record(bi, "PLC:$(AREA):$(LOCA):CCALARM") {
  field(DESC, "Cryocon total Alarm")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) Cryocon_Alarm")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "PLC:$(AREA):$(LOCA):CC2FAILED") {
  field(DESC, "cryocon 2 failed")
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) Cryocon2.Failed")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
}

record(bi, "PLC:$(AREA):$(LOCA):CC1FAILED") {
  field(DESC, "cryocon 1 failed")
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) Cryocon1.Failed")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
}

record(bi, "PLC:$(AREA):$(LOCA):CC3FAILED") {
  field(DESC, "cryocon 3 failed")
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) Cryocon3.Failed")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
}

record(bi, "PLC:$(AREA):$(LOCA):CC4FAILED") {
  field(DESC, "cryocon 4 failed")
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) Cryocon4.Failed")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
}

record(bi, "PLC:$(AREA):$(LOCA):CC5FAILED") {
  field(DESC, "cryocon 5 failed")
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) Cryocon5.Failed")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
}

record(bi, "PLC:$(AREA):$(LOCA):CC6FAILED") {
  field(DESC, "cryocon 6 failed")
  field(SCAN, "2 second")
  field(PINI, "YES")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) Cryocon6.Failed")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
}

record(bo, "PLC:$(AREA):$(LOCA):CCBYPASS_B3") {
  field(DESC, "Cryocon fault bypass 3")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) Cryocon_Byp B 3")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}

record(bo, "PLC:$(AREA):$(LOCA):CCBYPASS_B4") {
  field(DESC, "Cryocon fault bypass 4")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) Cryocon_Byp B 4")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}

record(bo, "PLC:$(AREA):$(LOCA):CCBYPASS_B5") {
  field(DESC, "Cryocon fault bypass 5")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) Cryocon_Byp B 5")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}

record(bo, "PLC:$(AREA):$(LOCA):CCBYPASS_B6") {
  field(DESC, "Cryocon fault bypass 6")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) Cryocon_Byp B 6")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}

record(mbbiDirect, "PLC:$(AREA):$(LOCA):Alarm1") {
  field(DESC, "PLC card faults")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) PLC_Alarm[1] B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}

record(bi, "PLC:$(AREA):$(LOCA):ALARM1_B0") {
  field(DESC, "ENet Alarm1 B0")
  field(SCAN, "2 second")
  field(DTYP, "Soft Channel")
  field(INP, "PLC:$(AREA):$(LOCA):Alarm1.B0")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "PLC:$(AREA):$(LOCA):ALARM1_B1") {
  field(DESC, "R2S1 ALARM B1")
  field(SCAN, "2 second")
  field(DTYP, "Soft Channel")
  field(INP, "PLC:$(AREA):$(LOCA):Alarm1.B1")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "PLC:$(AREA):$(LOCA):ALARM1_B2") {
  field(DESC, "R2S2 ALARM B2")
  field(SCAN, "2 second")
  field(DTYP, "Soft Channel")
  field(INP, "PLC:$(AREA):$(LOCA):Alarm1.B2")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "PLC:$(AREA):$(LOCA):ALARM1_B3") {
  field(DESC, "R2S3 ALARM B3")
  field(SCAN, "2 second")
  field(DTYP, "Soft Channel")
  field(INP, "PLC:$(AREA):$(LOCA):Alarm1.B3")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "PLC:$(AREA):$(LOCA):ALARM1_B4") {
  field(DESC, "R2S4 ALARM B4")
  field(SCAN, "2 second")
  field(DTYP, "Soft Channel")
  field(INP, "PLC:$(AREA):$(LOCA):Alarm1.B4")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "PLC:$(AREA):$(LOCA):ALARM1_B5") {
  field(DESC, "R2S5ALARM B5")
  field(SCAN, "2 second")
  field(DTYP, "Soft Channel")
  field(INP, "PLC:$(AREA):$(LOCA):Alarm1.B5")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "PLC:$(AREA):$(LOCA):ALARM1_B6") {
  field(DESC, "R2S6 ALARM B6")
  field(SCAN, "2 second")
  field(DTYP, "Soft Channel")
  field(INP, "PLC:$(AREA):$(LOCA):Alarm1.B6")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "PLC:$(AREA):$(LOCA):ALARM1_B7") {
  field(DESC, "R2S7 ALARM B7")
  field(SCAN, "2 second")
  field(DTYP, "Soft Channel")
  field(INP, "PLC:$(AREA):$(LOCA):Alarm1.B7")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(bi, "PLC:$(AREA):$(LOCA):ALARM1_B8") {
  field(DESC, "R2S8 ALARM B8")
  field(SCAN, "2 second")
  field(DTYP, "Soft Channel")
  field(INP, "PLC:$(AREA):$(LOCA):Alarm1.B8")
  field(ZNAM, "OK")
  field(ONAM, "FAULT")
  field(PINI, "YES")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
}

record(mbbiDirect, "PLC:$(AREA):$(LOCA):AlarmL1") {
  field(DESC, "PLC card fault latches")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) PLC_AlarmL[1] B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}

record(mbbiDirect, "PLC:$(AREA):$(LOCA):CH_R2S1FAULTS") {
  field(DESC, "PLC card channel faults")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) ChannelFaults[18] B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}

record(mbbiDirect, "PLC:$(AREA):$(LOCA):CH_R2S2FAULTS") {
  field(DESC, "PLC card channel faults")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) ChannelFaults[19] B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}

record(mbbiDirect, "PLC:$(AREA):$(LOCA):CH_R2S3FAULTS") {
  field(DESC, "PLC card channel faults")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) ChannelFaults[20] B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}

record(mbbiDirect, "PLC:$(AREA):$(LOCA):CH_R2S4FAULTS") {
  field(DESC, "PLC card channel faults")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) ChannelFaults[21] B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}

record(mbbiDirect, "PLC:$(AREA):$(LOCA):CH_R2S5FAULTS") {
  field(DESC, "PLC card channel faults")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) ChannelFaults[22] B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}

record(mbbiDirect, "PLC:$(AREA):$(LOCA):CH_R2S6FAULTS") {
  field(DESC, "PLC card channel faults")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) ChannelFaults[23] B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}

record(mbbiDirect, "PLC:$(AREA):$(LOCA):CH_R2S7FAULTS") {
  field(DESC, "PLC card channel faults")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) ChannelFaults[24] B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}

record(mbbiDirect, "PLC:$(AREA):$(LOCA):CH_R2S8FAULTS") {
  field(DESC, "PLC card channel faults")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) ChannelFaults[25] B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}

record(bo, "PLC:$(AREA):$(LOCA):BYPASS1_B0") {
  field(DESC, "Enet Card fault bypass")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 0")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}

record(bo, "PLC:$(AREA):$(LOCA):BYPASS1_B1") {
  field(DESC, "R2S1 card fault bypass")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 1")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}

record(bo, "PLC:$(AREA):$(LOCA):BYPASS1_B2") {
  field(DESC, "R2S2 card fault bypass")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 2")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}

record(bo, "PLC:$(AREA):$(LOCA):BYPASS1_B3") {
  field(DESC, "R2S3 card fault bypass")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 3")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}

record(bo, "PLC:$(AREA):$(LOCA):BYPASS1_B4") {
  field(DESC, "R2S4 card fault bypass")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 4")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}

record(bo, "PLC:$(AREA):$(LOCA):BYPASS1_B5") {
  field(DESC, "R2S5 card fault bypass")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 5")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}

record(bo, "PLC:$(AREA):$(LOCA):BYPASS1_B6") {
  field(DESC, "R2S6 card fault bypass")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 6")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}

record(bo, "PLC:$(AREA):$(LOCA):BYPASS1_B7") {
  field(DESC, "R2S7 card fault bypass")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 7")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}


record(bo, "PLC:$(AREA):$(LOCA):BYPASS1_B8") {
  field(DESC, "R2S8 card fault bypass")
  field(SCAN, "Passive")
  field(DTYP, "EtherIP")
  field(OUT, "@$(PLC_NAME) PLC_Alarm_Byp[1] B 8")
  field(ZNAM, "ACT")
  field(ONAM, "BYP")
  field(ASG, "CRYO")
  field(PINI, "NO")
  field(HIGH, "0")
}

record(mbbiDirect, "PLC:$(AREA):$(LOCA):CH_FAULTS11") {
  field(DESC, "PLC card channel faults")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) ChannelFaults[11] B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}

record(mbbiDirect, "PLC:$(AREA):$(LOCA):CH_FAULTS12") {
  field(DESC, "PLC card channel faults")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) ChannelFaults[12] B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}

record(mbbiDirect, "PLC:$(AREA):$(LOCA):CH_FAULTS13") {
  field(DESC, "PLC card channel faults")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) ChannelFaults[13] B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}

record(mbbiDirect, "PLC:$(AREA):$(LOCA):CH_FAULTS14") {
  field(DESC, "PLC card channel faults")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) ChannelFaults[14] B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}

record(mbbiDirect, "PLC:$(AREA):$(LOCA):CH_FAULTS10") {
  field(DESC, "PLC card channel faults")
  field(SCAN, "2 second")
  field(DTYP, "EtherIP")
  field(INP, "@$(PLC_NAME) ChannelFaults[10] B 0")
  field(NOBT, "16")
  field(PINI, "YES")
}

#! Further lines contain data used by VisualDCT
#! View(0,273,1.0)
#! Record("PLC:$(AREA):$(LOCA):CCAlarmL",160,1280,0,1,"PLC:$(AREA):$(LOCA):CCAlarmL")
#! Record("PLC:$(AREA):$(LOCA):CCBYPASS_B0",160,1079,0,1,"PLC:$(AREA):$(LOCA):CCBYPASS_B0")
#! Record("PLC:$(AREA):$(LOCA):CCBYPASS_B1",360,1079,0,1,"PLC:$(AREA):$(LOCA):CCBYPASS_B1")
#! Record("PLC:$(AREA):$(LOCA):CCBYPASS_B2",560,1079,0,1,"PLC:$(AREA):$(LOCA):CCBYPASS_B2")
#! Record("PLC:$(AREA):$(LOCA):CCALARM",160,859,0,1,"PLC:$(AREA):$(LOCA):CCALARM")
#! Record("PLC:$(AREA):$(LOCA):CC2FAILED",560,859,0,1,"PLC:$(AREA):$(LOCA):CC2FAILED")
#! Record("PLC:$(AREA):$(LOCA):CC1FAILED",360,859,0,1,"PLC:$(AREA):$(LOCA):CC1FAILED")
#! Record("PLC:$(AREA):$(LOCA):CC3FAILED",761,859,0,1,"PLC:$(AREA):$(LOCA):CC3FAILED")
#! Record("PLC:$(AREA):$(LOCA):CC4FAILED",961,859,0,1,"PLC:$(AREA):$(LOCA):CC4FAILED")
#! Record("PLC:$(AREA):$(LOCA):CC5FAILED",1160,859,0,1,"PLC:$(AREA):$(LOCA):CC5FAILED")
#! Record("PLC:$(AREA):$(LOCA):CC6FAILED",1360,859,0,1,"PLC:$(AREA):$(LOCA):CC6FAILED")
#! Record("PLC:$(AREA):$(LOCA):CCBYPASS_B3",762,1079,0,1,"PLC:$(AREA):$(LOCA):CCBYPASS_B3")
#! Record("PLC:$(AREA):$(LOCA):CCBYPASS_B4",962,1079,0,1,"PLC:$(AREA):$(LOCA):CCBYPASS_B4")
#! Record("PLC:$(AREA):$(LOCA):CCBYPASS_B5",1160,1079,0,1,"PLC:$(AREA):$(LOCA):CCBYPASS_B5")
#! Record("PLC:$(AREA):$(LOCA):CCBYPASS_B6",1360,1079,0,1,"PLC:$(AREA):$(LOCA):CCBYPASS_B6")
#! Record("PLC:$(AREA):$(LOCA):Alarm1",100,2160,0,1,"PLC:$(AREA):$(LOCA):Alarm1")
#! Field("PLC:$(AREA):$(LOCA):Alarm1.B0",16777215,0,"PLC:$(AREA):$(LOCA):Alarm1.B0")
#! Field("PLC:$(AREA):$(LOCA):Alarm1.B1",16777215,1,"PLC:$(AREA):$(LOCA):Alarm1.B1")
#! Field("PLC:$(AREA):$(LOCA):Alarm1.B2",16777215,1,"PLC:$(AREA):$(LOCA):Alarm1.B2")
#! Field("PLC:$(AREA):$(LOCA):Alarm1.B3",16777215,1,"PLC:$(AREA):$(LOCA):Alarm1.B3")
#! Field("PLC:$(AREA):$(LOCA):Alarm1.B4",16777215,1,"PLC:$(AREA):$(LOCA):Alarm1.B4")
#! Field("PLC:$(AREA):$(LOCA):Alarm1.B5",16777215,1,"PLC:$(AREA):$(LOCA):Alarm1.B5")
#! Field("PLC:$(AREA):$(LOCA):Alarm1.B6",16777215,1,"PLC:$(AREA):$(LOCA):Alarm1.B6")
#! Field("PLC:$(AREA):$(LOCA):Alarm1.B7",16777215,1,"PLC:$(AREA):$(LOCA):Alarm1.B7")
#! Field("PLC:$(AREA):$(LOCA):Alarm1.B8",16777215,0,"PLC:$(AREA):$(LOCA):Alarm1.B8")
#! Record("PLC:$(AREA):$(LOCA):ALARM1_B0",340,2079,0,1,"PLC:$(AREA):$(LOCA):ALARM1_B0")
#! Field("PLC:$(AREA):$(LOCA):ALARM1_B0.INP",16777215,0,"PLC:$(AREA):$(LOCA):ALARM1_B0.INP")
#! Link("PLC:$(AREA):$(LOCA):ALARM1_B0.INP","PLC:$(AREA):$(LOCA):Alarm1.B0")
#! Record("PLC:$(AREA):$(LOCA):ALARM1_B1",520,2079,0,1,"PLC:$(AREA):$(LOCA):ALARM1_B1")
#! Field("PLC:$(AREA):$(LOCA):ALARM1_B1.INP",16777215,0,"PLC:$(AREA):$(LOCA):ALARM1_B1.INP")
#! Link("PLC:$(AREA):$(LOCA):ALARM1_B1.INP","PLC:$(AREA):$(LOCA):Alarm1.B1")
#! Record("PLC:$(AREA):$(LOCA):ALARM1_B2",700,2079,0,1,"PLC:$(AREA):$(LOCA):ALARM1_B2")
#! Field("PLC:$(AREA):$(LOCA):ALARM1_B2.INP",16777215,0,"PLC:$(AREA):$(LOCA):ALARM1_B2.INP")
#! Link("PLC:$(AREA):$(LOCA):ALARM1_B2.INP","PLC:$(AREA):$(LOCA):Alarm1.B2")
#! Record("PLC:$(AREA):$(LOCA):ALARM1_B3",880,2079,0,1,"PLC:$(AREA):$(LOCA):ALARM1_B3")
#! Field("PLC:$(AREA):$(LOCA):ALARM1_B3.INP",16777215,0,"PLC:$(AREA):$(LOCA):ALARM1_B3.INP")
#! Link("PLC:$(AREA):$(LOCA):ALARM1_B3.INP","PLC:$(AREA):$(LOCA):Alarm1.B3")
#! Record("PLC:$(AREA):$(LOCA):ALARM1_B4",1060,2079,0,1,"PLC:$(AREA):$(LOCA):ALARM1_B4")
#! Field("PLC:$(AREA):$(LOCA):ALARM1_B4.INP",16777215,0,"PLC:$(AREA):$(LOCA):ALARM1_B4.INP")
#! Link("PLC:$(AREA):$(LOCA):ALARM1_B4.INP","PLC:$(AREA):$(LOCA):Alarm1.B4")
#! Record("PLC:$(AREA):$(LOCA):ALARM1_B5",1240,2079,0,1,"PLC:$(AREA):$(LOCA):ALARM1_B5")
#! Field("PLC:$(AREA):$(LOCA):ALARM1_B5.INP",16777215,0,"PLC:$(AREA):$(LOCA):ALARM1_B5.INP")
#! Link("PLC:$(AREA):$(LOCA):ALARM1_B5.INP","PLC:$(AREA):$(LOCA):Alarm1.B5")
#! Record("PLC:$(AREA):$(LOCA):ALARM1_B6",1420,2079,0,1,"PLC:$(AREA):$(LOCA):ALARM1_B6")
#! Field("PLC:$(AREA):$(LOCA):ALARM1_B6.INP",16777215,0,"PLC:$(AREA):$(LOCA):ALARM1_B6.INP")
#! Link("PLC:$(AREA):$(LOCA):ALARM1_B6.INP","PLC:$(AREA):$(LOCA):Alarm1.B6")
#! Record("PLC:$(AREA):$(LOCA):ALARM1_B7",1600,2079,0,1,"PLC:$(AREA):$(LOCA):ALARM1_B7")
#! Field("PLC:$(AREA):$(LOCA):ALARM1_B7.INP",16777215,0,"PLC:$(AREA):$(LOCA):ALARM1_B7.INP")
#! Link("PLC:$(AREA):$(LOCA):ALARM1_B7.INP","PLC:$(AREA):$(LOCA):Alarm1.B7")
#! Record("PLC:$(AREA):$(LOCA):ALARM1_B8",360,2319,0,1,"PLC:$(AREA):$(LOCA):ALARM1_B8")
#! Field("PLC:$(AREA):$(LOCA):ALARM1_B8.INP",16777215,0,"PLC:$(AREA):$(LOCA):ALARM1_B8.INP")
#! Link("PLC:$(AREA):$(LOCA):ALARM1_B8.INP","PLC:$(AREA):$(LOCA):Alarm1.B8")
#! Record("PLC:$(AREA):$(LOCA):AlarmL1",440,1860,0,1,"PLC:$(AREA):$(LOCA):AlarmL1")
#! Record("PLC:$(AREA):$(LOCA):CH_R2S1FAULTS",140,600,0,1,"PLC:$(AREA):$(LOCA):CH_R2S1FAULTS")
#! Record("PLC:$(AREA):$(LOCA):CH_R2S2FAULTS",320,600,0,1,"PLC:$(AREA):$(LOCA):CH_R2S2FAULTS")
#! Record("PLC:$(AREA):$(LOCA):CH_R2S3FAULTS",500,600,0,1,"PLC:$(AREA):$(LOCA):CH_R2S3FAULTS")
#! Record("PLC:$(AREA):$(LOCA):CH_R2S4FAULTS",680,600,0,1,"PLC:$(AREA):$(LOCA):CH_R2S4FAULTS")
#! Record("PLC:$(AREA):$(LOCA):CH_R2S5FAULTS",860,600,0,1,"PLC:$(AREA):$(LOCA):CH_R2S5FAULTS")
#! Record("PLC:$(AREA):$(LOCA):CH_R2S6FAULTS",1040,600,0,1,"PLC:$(AREA):$(LOCA):CH_R2S6FAULTS")
#! Record("PLC:$(AREA):$(LOCA):CH_R2S7FAULTS",1220,600,0,1,"PLC:$(AREA):$(LOCA):CH_R2S7FAULTS")
#! Record("PLC:$(AREA):$(LOCA):CH_R2S8FAULTS",1400,600,0,1,"PLC:$(AREA):$(LOCA):CH_R2S8FAULTS")
#! Record("PLC:$(AREA):$(LOCA):BYPASS1_B0",80,1619,0,1,"PLC:$(AREA):$(LOCA):BYPASS1_B0")
#! Record("PLC:$(AREA):$(LOCA):BYPASS1_B1",260,1619,0,1,"PLC:$(AREA):$(LOCA):BYPASS1_B1")
#! Record("PLC:$(AREA):$(LOCA):BYPASS1_B2",440,1619,0,1,"PLC:$(AREA):$(LOCA):BYPASS1_B2")
#! Record("PLC:$(AREA):$(LOCA):BYPASS1_B3",620,1619,0,1,"PLC:$(AREA):$(LOCA):BYPASS1_B3")
#! Record("PLC:$(AREA):$(LOCA):BYPASS1_B4",800,1619,0,1,"PLC:$(AREA):$(LOCA):BYPASS1_B4")
#! Record("PLC:$(AREA):$(LOCA):BYPASS1_B5",980,1619,0,1,"PLC:$(AREA):$(LOCA):BYPASS1_B5")
#! Record("PLC:$(AREA):$(LOCA):BYPASS1_B6",1160,1619,0,1,"PLC:$(AREA):$(LOCA):BYPASS1_B6")
#! Record("PLC:$(AREA):$(LOCA):BYPASS1_B7",1340,1619,0,1,"PLC:$(AREA):$(LOCA):BYPASS1_B7")
#! Record("PLC:$(AREA):$(LOCA):BYPASS1_B8",1520,1619,0,1,"PLC:$(AREA):$(LOCA):BYPASS1_B8")
#! Record("PLC:$(AREA):$(LOCA):CH_FAULTS11",460,380,0,1,"PLC:$(AREA):$(LOCA):CH_FAULTS11")
#! Record("PLC:$(AREA):$(LOCA):CH_FAULTS12",640,380,0,1,"PLC:$(AREA):$(LOCA):CH_FAULTS12")
#! Record("PLC:$(AREA):$(LOCA):CH_FAULTS13",820,380,0,1,"PLC:$(AREA):$(LOCA):CH_FAULTS13")
#! Record("PLC:$(AREA):$(LOCA):CH_FAULTS14",1000,380,0,1,"PLC:$(AREA):$(LOCA):CH_FAULTS14")
#! Record("PLC:$(AREA):$(LOCA):CH_FAULTS10",280,380,0,1,"PLC:$(AREA):$(LOCA):CH_FAULTS10")
#! TextBox(TB0,1840,1900,1960,1900,0,"Dialog",12,1,16777215,"Latches for Alarm1",null)
#! TextBox(TB7,340,280,880,320,0,"Dialog",12,1,16777215,"CH_FAULTS1 MBBI word - PLC Card Channel Faults\n    - additional needed by utility PLC for R1 Slots 10 - 14\n",null)
#! TextBox(TB6,221,559,761,599,0,"Dialog",12,1,16777215,"CH_FAULTS1 MBBI word - PLC Card Channel Faults\n    - only those additional needed by utility PLC for rack 2\n",null)
#! TextBox(TB5,420,1820,900,1860,0,"Dialog",12,1,16777215,"Alarm Latch 1  - Additional alarm latches for Utilities PLC, Rack 2 Slots\n",null)
#! TextBox(TB4,520,2040,1000,2080,0,"Dialog",12,1,16777215,"Alarm 1  - Additional fault alarms for Utilities PLC, Rack 2 Slots\n",null)
#! TextBox(TB3,580,1540,1060,1580,0,"Dialog",12,1,16777215,"Alarm Bypasses - Additional for Utilities PLC\n",null)
#! TextBox(TB2,160,800,640,840,0,"Dialog",12,1,16777215,"Cryocon Alarms, Bypasses, Latches - 6 Cryocons\n",null)