#! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP07:1010:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP07:1010:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP07:1010:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP07:1010:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP07:1010:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:SP_RQST") { field(DESC, "CPIC71010 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1010:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP07:1010:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "CPIC71010") } record(ao, "CPIC:CP07:1010:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP07:1010:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP07:1010:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP07:1010:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP07:1010:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71010_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP07:1010:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010_OVH.Mode_Status") } record(bi, "CPIC:CP07:1010:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP07:1010:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP07:1010:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP07:1010:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP07:1010:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP07:1010:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010_OVH.Mode_String") } record(bi, "CPIC:CP07:1010:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP07:1010:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP07:1010:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "CPV71010") } record(ai, "CPIC:CP07:1010:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP07:1010:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP07:1010:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.MODE") } record(bo, "CPIC:CP07:1010:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71010_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP07:1010:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71010_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP07:1010:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71010_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP07:1010:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP07:1010:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71010.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP07:1010:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP07:1010:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP07:1010:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71010o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP07:1010:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP07:1010:ORBV",2100,2312,0,1,"CPIC:CP07:1010:ORBV") #! Record("CPIC:CP07:1010:OVAL",2280,2312,0,1,"CPIC:CP07:1010:OVAL") #! Record("CPIC:CP07:1010:CVAL",2460,2312,0,1,"CPIC:CP07:1010:CVAL") #! Record("CPIC:CP07:1010:MAX",2122,1932,0,1,"CPIC:CP07:1010:MAX") #! Record("CPIC:CP07:1010:DMIN",2300,1932,0,1,"CPIC:CP07:1010:DMIN") #! Record("CPIC:CP07:1010:DMAX",2479,1932,0,1,"CPIC:CP07:1010:DMAX") #! Record("CPIC:CP07:1010:MDT",2120,2112,0,1,"CPIC:CP07:1010:MDT") #! Record("CPIC:CP07:1010:KP",2300,2106,0,1,"CPIC:CP07:1010:KP") #! Record("CPIC:CP07:1010:KI",2480,2106,0,1,"CPIC:CP07:1010:KI") #! Record("CPIC:CP07:1010:KD",2660,2106,0,1,"CPIC:CP07:1010:KD") #! Record("CPIC:CP07:1010:S",2840,2120,0,1,"CPIC:CP07:1010:S") #! Record("CPIC:CP07:1010:SP_RQST",1760,1932,0,1,"CPIC:CP07:1010:SP_RQST") #! Record("CPIC:CP07:1010:MIN",1945,1932,0,1,"CPIC:CP07:1010:MIN") #! Record("CPIC:CP07:1010:PIDTAG",1740,2462,0,1,"CPIC:CP07:1010:PIDTAG") #! Record("CPIC:CP07:1010:PEVAL",2660,1932,0,1,"CPIC:CP07:1010:PEVAL") #! Record("CPIC:CP07:1010:FSB",2840,1932,0,1,"CPIC:CP07:1010:FSB") #! Record("CPIC:CP07:1010:NOMATCH",3180,2499,0,1,"CPIC:CP07:1010:NOMATCH") #! Record("CPIC:CP07:1010:CHFAULT",3000,2506,0,1,"CPIC:CP07:1010:CHFAULT") #! Record("CPIC:CP07:1010:MANPOS_RQST",1940,2112,0,1,"CPIC:CP07:1010:MANPOS_RQST") #! Record("CPIC:CP07:1010:MODE_STATUS",1920,2314,0,1,"CPIC:CP07:1010:MODE_STATUS") #! Record("CPIC:CP07:1010:INTERLOCK",2460,2499,0,0,"CPIC:CP07:1010:INTERLOCK") #! Record("CPIC:CP07:1010:IVAL",2641,2312,0,1,"CPIC:CP07:1010:IVAL") #! Record("CPIC:CP07:1010:SVAL",2820,2312,0,1,"CPIC:CP07:1010:SVAL") #! Record("CPIC:CP07:1010:MMOD",2100,2506,0,1,"CPIC:CP07:1010:MMOD") #! Record("CPIC:CP07:1010:SMOD",2282,2506,0,1,"CPIC:CP07:1010:SMOD") #! Record("CPIC:CP07:1010:MODE_STRING",1740,2314,0,1,"CPIC:CP07:1010:MODE_STRING") #! Record("CPIC:CP07:1010:PMOD",1922,2479,0,1,"CPIC:CP07:1010:PMOD") #! Record("CPIC:CP07:1010:IMOD",2640,2499,0,1,"CPIC:CP07:1010:IMOD") #! Record("CPIC:CP07:1010:ACTUATOR",1740,2582,0,1,"CPIC:CP07:1010:ACTUATOR") #! Record("CPIC:CP07:1010:AVAL",3000,2312,0,1,"CPIC:CP07:1010:AVAL") #! Record("CPIC:CP07:1010:AMOD",2824,2506,0,1,"CPIC:CP07:1010:AMOD") #! Record("CPIC:CP07:1010:MODE",1760,2134,0,1,"CPIC:CP07:1010:MODE") #! Record("CPIC:CP07:1010:MANUAL",1951,2719,0,1,"CPIC:CP07:1010:MANUAL") #! Record("CPIC:CP07:1010:SEQUENCER",2140,2719,0,1,"CPIC:CP07:1010:SEQUENCER") #! Record("CPIC:CP07:1010:AUTO",2320,2719,0,1,"CPIC:CP07:1010:AUTO") #! Record("CPIC:CP07:1010:IL_LATCH",2680,2699,0,1,"CPIC:CP07:1010:IL_LATCH") #! Record("CPIC:CP07:1010:IL_RESET",2502,2719,0,1,"CPIC:CP07:1010:IL_RESET") #! Record("CPIC:CP07:1010:MVAL",3175,2312,0,1,"CPIC:CP07:1010:MVAL") #! Record("CPIC:CP07:1010:PVAL",3360,2312,0,1,"CPIC:CP07:1010:PVAL") #! Record("CPIC:CP07:1010:CMD_OUT",3042,1932,0,1,"CPIC:CP07:1010:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP07 cryoplant number and area in cryoplant\n1010 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP07:1010:TEXT1",1739,2702,0,1,"CPIC:CP07:1010:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP07:1020:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP07:1020:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP07:1020:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP07:1020:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP07:1020:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:SP_RQST") { field(DESC, "CPIC71020 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP07:1020:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP07:1020:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "CPIC71020") } record(ao, "CPIC:CP07:1020:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP07:1020:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP07:1020:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP07:1020:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP07:1020:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV71020_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP07:1020:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020_OVH.Mode_Status") } record(bi, "CPIC:CP07:1020:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP07:1020:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP07:1020:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP07:1020:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP07:1020:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP07:1020:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020_OVH.Mode_String") } record(bi, "CPIC:CP07:1020:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP07:1020:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP07:1020:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "CPV71020") } record(ai, "CPIC:CP07:1020:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP07:1020:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP07:1020:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.MODE") } record(bo, "CPIC:CP07:1020:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71020_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP07:1020:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71020_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP07:1020:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71020_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP07:1020:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP07:1020:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV71020.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP07:1020:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP07:1020:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP07:1020:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV71020o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP07:1020:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP07:1020:ORBV",2100,2312,0,1,"CPIC:CP07:1020:ORBV") #! Record("CPIC:CP07:1020:OVAL",2280,2312,0,1,"CPIC:CP07:1020:OVAL") #! Record("CPIC:CP07:1020:CVAL",2460,2312,0,1,"CPIC:CP07:1020:CVAL") #! Record("CPIC:CP07:1020:MAX",2122,1932,0,1,"CPIC:CP07:1020:MAX") #! Record("CPIC:CP07:1020:DMIN",2300,1932,0,1,"CPIC:CP07:1020:DMIN") #! Record("CPIC:CP07:1020:DMAX",2479,1932,0,1,"CPIC:CP07:1020:DMAX") #! Record("CPIC:CP07:1020:MDT",2120,2112,0,1,"CPIC:CP07:1020:MDT") #! Record("CPIC:CP07:1020:KP",2300,2106,0,1,"CPIC:CP07:1020:KP") #! Record("CPIC:CP07:1020:KI",2480,2106,0,1,"CPIC:CP07:1020:KI") #! Record("CPIC:CP07:1020:KD",2660,2106,0,1,"CPIC:CP07:1020:KD") #! Record("CPIC:CP07:1020:S",2840,2120,0,1,"CPIC:CP07:1020:S") #! Record("CPIC:CP07:1020:SP_RQST",1760,1932,0,1,"CPIC:CP07:1020:SP_RQST") #! Record("CPIC:CP07:1020:MIN",1945,1932,0,1,"CPIC:CP07:1020:MIN") #! Record("CPIC:CP07:1020:PIDTAG",1740,2462,0,1,"CPIC:CP07:1020:PIDTAG") #! Record("CPIC:CP07:1020:PEVAL",2660,1932,0,1,"CPIC:CP07:1020:PEVAL") #! Record("CPIC:CP07:1020:FSB",2840,1932,0,1,"CPIC:CP07:1020:FSB") #! Record("CPIC:CP07:1020:NOMATCH",3180,2499,0,1,"CPIC:CP07:1020:NOMATCH") #! Record("CPIC:CP07:1020:CHFAULT",3000,2506,0,1,"CPIC:CP07:1020:CHFAULT") #! Record("CPIC:CP07:1020:MANPOS_RQST",1940,2112,0,1,"CPIC:CP07:1020:MANPOS_RQST") #! Record("CPIC:CP07:1020:MODE_STATUS",1920,2314,0,1,"CPIC:CP07:1020:MODE_STATUS") #! Record("CPIC:CP07:1020:INTERLOCK",2460,2499,0,0,"CPIC:CP07:1020:INTERLOCK") #! Record("CPIC:CP07:1020:IVAL",2641,2312,0,1,"CPIC:CP07:1020:IVAL") #! Record("CPIC:CP07:1020:SVAL",2820,2312,0,1,"CPIC:CP07:1020:SVAL") #! Record("CPIC:CP07:1020:MMOD",2100,2506,0,1,"CPIC:CP07:1020:MMOD") #! Record("CPIC:CP07:1020:SMOD",2282,2506,0,1,"CPIC:CP07:1020:SMOD") #! Record("CPIC:CP07:1020:MODE_STRING",1740,2314,0,1,"CPIC:CP07:1020:MODE_STRING") #! Record("CPIC:CP07:1020:PMOD",1922,2479,0,1,"CPIC:CP07:1020:PMOD") #! Record("CPIC:CP07:1020:IMOD",2640,2499,0,1,"CPIC:CP07:1020:IMOD") #! Record("CPIC:CP07:1020:ACTUATOR",1740,2582,0,1,"CPIC:CP07:1020:ACTUATOR") #! Record("CPIC:CP07:1020:AVAL",3000,2312,0,1,"CPIC:CP07:1020:AVAL") #! Record("CPIC:CP07:1020:AMOD",2824,2506,0,1,"CPIC:CP07:1020:AMOD") #! Record("CPIC:CP07:1020:MODE",1760,2134,0,1,"CPIC:CP07:1020:MODE") #! Record("CPIC:CP07:1020:MANUAL",1951,2719,0,1,"CPIC:CP07:1020:MANUAL") #! Record("CPIC:CP07:1020:SEQUENCER",2140,2719,0,1,"CPIC:CP07:1020:SEQUENCER") #! Record("CPIC:CP07:1020:AUTO",2320,2719,0,1,"CPIC:CP07:1020:AUTO") #! Record("CPIC:CP07:1020:IL_LATCH",2680,2699,0,1,"CPIC:CP07:1020:IL_LATCH") #! Record("CPIC:CP07:1020:IL_RESET",2502,2719,0,1,"CPIC:CP07:1020:IL_RESET") #! Record("CPIC:CP07:1020:MVAL",3175,2312,0,1,"CPIC:CP07:1020:MVAL") #! Record("CPIC:CP07:1020:PVAL",3360,2312,0,1,"CPIC:CP07:1020:PVAL") #! Record("CPIC:CP07:1020:CMD_OUT",3042,1932,0,1,"CPIC:CP07:1020:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP07 cryoplant number and area in cryoplant\n1020 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP07:1020:TEXT1",1739,2702,0,1,"CPIC:CP07:1020:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP15:1001:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP15:1001:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP15:1001:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP15:1001:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51001_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1001:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51001_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1001:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51001_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1001:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51001_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1001:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51001_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1001:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51001_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1001:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51001_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP15:1001:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51001_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1001:SP_RQST") { field(DESC, "C1PIC51001 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51001_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1001:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51001_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP15:1001:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C1PIC51001") } record(ao, "CPIC:CP15:1001:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51001.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP15:1001:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51001.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP15:1001:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP15:1001:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP15:1001:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51001_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP15:1001:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001_OVH.Mode_Status") } record(bi, "CPIC:CP15:1001:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP15:1001:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1001:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP15:1001:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP15:1001:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP15:1001:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001_OVH.Mode_String") } record(bi, "CPIC:CP15:1001:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP15:1001:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP15:1001:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "C1PV51001") } record(ai, "CPIC:CP15:1001:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP15:1001:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP15:1001:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.MODE") } record(bo, "CPIC:CP15:1001:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51001_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP15:1001:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51001_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP15:1001:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51001_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP15:1001:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP15:1001:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51001.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP15:1001:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1001:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1001:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51001o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP15:1001:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP15:1001:ORBV",2100,2312,0,1,"CPIC:CP15:1001:ORBV") #! Record("CPIC:CP15:1001:OVAL",2280,2312,0,1,"CPIC:CP15:1001:OVAL") #! Record("CPIC:CP15:1001:CVAL",2460,2312,0,1,"CPIC:CP15:1001:CVAL") #! Record("CPIC:CP15:1001:MAX",2122,1932,0,1,"CPIC:CP15:1001:MAX") #! Record("CPIC:CP15:1001:DMIN",2300,1932,0,1,"CPIC:CP15:1001:DMIN") #! Record("CPIC:CP15:1001:DMAX",2479,1932,0,1,"CPIC:CP15:1001:DMAX") #! Record("CPIC:CP15:1001:MDT",2120,2112,0,1,"CPIC:CP15:1001:MDT") #! Record("CPIC:CP15:1001:KP",2300,2106,0,1,"CPIC:CP15:1001:KP") #! Record("CPIC:CP15:1001:KI",2480,2106,0,1,"CPIC:CP15:1001:KI") #! Record("CPIC:CP15:1001:KD",2660,2106,0,1,"CPIC:CP15:1001:KD") #! Record("CPIC:CP15:1001:S",2840,2120,0,1,"CPIC:CP15:1001:S") #! Record("CPIC:CP15:1001:SP_RQST",1760,1932,0,1,"CPIC:CP15:1001:SP_RQST") #! Record("CPIC:CP15:1001:MIN",1945,1932,0,1,"CPIC:CP15:1001:MIN") #! Record("CPIC:CP15:1001:PIDTAG",1740,2462,0,1,"CPIC:CP15:1001:PIDTAG") #! Record("CPIC:CP15:1001:PEVAL",2660,1932,0,1,"CPIC:CP15:1001:PEVAL") #! Record("CPIC:CP15:1001:FSB",2840,1932,0,1,"CPIC:CP15:1001:FSB") #! Record("CPIC:CP15:1001:NOMATCH",3180,2499,0,1,"CPIC:CP15:1001:NOMATCH") #! Record("CPIC:CP15:1001:CHFAULT",3000,2506,0,1,"CPIC:CP15:1001:CHFAULT") #! Record("CPIC:CP15:1001:MANPOS_RQST",1940,2112,0,1,"CPIC:CP15:1001:MANPOS_RQST") #! Record("CPIC:CP15:1001:MODE_STATUS",1920,2314,0,1,"CPIC:CP15:1001:MODE_STATUS") #! Record("CPIC:CP15:1001:INTERLOCK",2460,2499,0,0,"CPIC:CP15:1001:INTERLOCK") #! Record("CPIC:CP15:1001:IVAL",2641,2312,0,1,"CPIC:CP15:1001:IVAL") #! Record("CPIC:CP15:1001:SVAL",2820,2312,0,1,"CPIC:CP15:1001:SVAL") #! Record("CPIC:CP15:1001:MMOD",2100,2506,0,1,"CPIC:CP15:1001:MMOD") #! Record("CPIC:CP15:1001:SMOD",2282,2506,0,1,"CPIC:CP15:1001:SMOD") #! Record("CPIC:CP15:1001:MODE_STRING",1740,2314,0,1,"CPIC:CP15:1001:MODE_STRING") #! Record("CPIC:CP15:1001:PMOD",1922,2479,0,1,"CPIC:CP15:1001:PMOD") #! Record("CPIC:CP15:1001:IMOD",2640,2499,0,1,"CPIC:CP15:1001:IMOD") #! Record("CPIC:CP15:1001:ACTUATOR",1740,2582,0,1,"CPIC:CP15:1001:ACTUATOR") #! Record("CPIC:CP15:1001:AVAL",3000,2312,0,1,"CPIC:CP15:1001:AVAL") #! Record("CPIC:CP15:1001:AMOD",2824,2506,0,1,"CPIC:CP15:1001:AMOD") #! Record("CPIC:CP15:1001:MODE",1760,2134,0,1,"CPIC:CP15:1001:MODE") #! Record("CPIC:CP15:1001:MANUAL",1951,2719,0,1,"CPIC:CP15:1001:MANUAL") #! Record("CPIC:CP15:1001:SEQUENCER",2140,2719,0,1,"CPIC:CP15:1001:SEQUENCER") #! Record("CPIC:CP15:1001:AUTO",2320,2719,0,1,"CPIC:CP15:1001:AUTO") #! Record("CPIC:CP15:1001:IL_LATCH",2680,2699,0,1,"CPIC:CP15:1001:IL_LATCH") #! Record("CPIC:CP15:1001:IL_RESET",2502,2719,0,1,"CPIC:CP15:1001:IL_RESET") #! Record("CPIC:CP15:1001:MVAL",3175,2312,0,1,"CPIC:CP15:1001:MVAL") #! Record("CPIC:CP15:1001:PVAL",3360,2312,0,1,"CPIC:CP15:1001:PVAL") #! Record("CPIC:CP15:1001:CMD_OUT",3042,1932,0,1,"CPIC:CP15:1001:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP15 cryoplant number and area in cryoplant\n1001 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP15:1001:TEXT1",1739,2702,0,1,"CPIC:CP15:1001:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP15:1003:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP15:1003:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP15:1003:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP15:1003:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51003_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1003:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51003_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1003:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51003_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1003:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51003_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1003:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51003_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1003:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51003_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1003:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51003_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP15:1003:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51003_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1003:SP_RQST") { field(DESC, "C1PIC51003 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51003_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1003:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51003_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP15:1003:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C1PIC51003") } record(ao, "CPIC:CP15:1003:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51003.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP15:1003:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51003.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP15:1003:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP15:1003:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP15:1003:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51003_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP15:1003:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003_OVH.Mode_Status") } record(bi, "CPIC:CP15:1003:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP15:1003:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1003:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP15:1003:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP15:1003:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP15:1003:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003_OVH.Mode_String") } record(bi, "CPIC:CP15:1003:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP15:1003:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP15:1003:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "C1PV51003") } record(ai, "CPIC:CP15:1003:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP15:1003:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP15:1003:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.MODE") } record(bo, "CPIC:CP15:1003:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51003_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP15:1003:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51003_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP15:1003:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51003_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP15:1003:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP15:1003:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51003.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP15:1003:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1003:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1003:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51003o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP15:1003:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP15:1003:ORBV",2100,2312,0,1,"CPIC:CP15:1003:ORBV") #! Record("CPIC:CP15:1003:OVAL",2280,2312,0,1,"CPIC:CP15:1003:OVAL") #! Record("CPIC:CP15:1003:CVAL",2460,2312,0,1,"CPIC:CP15:1003:CVAL") #! Record("CPIC:CP15:1003:MAX",2122,1932,0,1,"CPIC:CP15:1003:MAX") #! Record("CPIC:CP15:1003:DMIN",2300,1932,0,1,"CPIC:CP15:1003:DMIN") #! Record("CPIC:CP15:1003:DMAX",2479,1932,0,1,"CPIC:CP15:1003:DMAX") #! Record("CPIC:CP15:1003:MDT",2120,2112,0,1,"CPIC:CP15:1003:MDT") #! Record("CPIC:CP15:1003:KP",2300,2106,0,1,"CPIC:CP15:1003:KP") #! Record("CPIC:CP15:1003:KI",2480,2106,0,1,"CPIC:CP15:1003:KI") #! Record("CPIC:CP15:1003:KD",2660,2106,0,1,"CPIC:CP15:1003:KD") #! Record("CPIC:CP15:1003:S",2840,2120,0,1,"CPIC:CP15:1003:S") #! Record("CPIC:CP15:1003:SP_RQST",1760,1932,0,1,"CPIC:CP15:1003:SP_RQST") #! Record("CPIC:CP15:1003:MIN",1945,1932,0,1,"CPIC:CP15:1003:MIN") #! Record("CPIC:CP15:1003:PIDTAG",1740,2462,0,1,"CPIC:CP15:1003:PIDTAG") #! Record("CPIC:CP15:1003:PEVAL",2660,1932,0,1,"CPIC:CP15:1003:PEVAL") #! Record("CPIC:CP15:1003:FSB",2840,1932,0,1,"CPIC:CP15:1003:FSB") #! Record("CPIC:CP15:1003:NOMATCH",3180,2499,0,1,"CPIC:CP15:1003:NOMATCH") #! Record("CPIC:CP15:1003:CHFAULT",3000,2506,0,1,"CPIC:CP15:1003:CHFAULT") #! Record("CPIC:CP15:1003:MANPOS_RQST",1940,2112,0,1,"CPIC:CP15:1003:MANPOS_RQST") #! Record("CPIC:CP15:1003:MODE_STATUS",1920,2314,0,1,"CPIC:CP15:1003:MODE_STATUS") #! Record("CPIC:CP15:1003:INTERLOCK",2460,2499,0,0,"CPIC:CP15:1003:INTERLOCK") #! Record("CPIC:CP15:1003:IVAL",2641,2312,0,1,"CPIC:CP15:1003:IVAL") #! Record("CPIC:CP15:1003:SVAL",2820,2312,0,1,"CPIC:CP15:1003:SVAL") #! Record("CPIC:CP15:1003:MMOD",2100,2506,0,1,"CPIC:CP15:1003:MMOD") #! Record("CPIC:CP15:1003:SMOD",2282,2506,0,1,"CPIC:CP15:1003:SMOD") #! Record("CPIC:CP15:1003:MODE_STRING",1740,2314,0,1,"CPIC:CP15:1003:MODE_STRING") #! Record("CPIC:CP15:1003:PMOD",1922,2479,0,1,"CPIC:CP15:1003:PMOD") #! Record("CPIC:CP15:1003:IMOD",2640,2499,0,1,"CPIC:CP15:1003:IMOD") #! Record("CPIC:CP15:1003:ACTUATOR",1740,2582,0,1,"CPIC:CP15:1003:ACTUATOR") #! Record("CPIC:CP15:1003:AVAL",3000,2312,0,1,"CPIC:CP15:1003:AVAL") #! Record("CPIC:CP15:1003:AMOD",2824,2506,0,1,"CPIC:CP15:1003:AMOD") #! Record("CPIC:CP15:1003:MODE",1760,2134,0,1,"CPIC:CP15:1003:MODE") #! Record("CPIC:CP15:1003:MANUAL",1951,2719,0,1,"CPIC:CP15:1003:MANUAL") #! Record("CPIC:CP15:1003:SEQUENCER",2140,2719,0,1,"CPIC:CP15:1003:SEQUENCER") #! Record("CPIC:CP15:1003:AUTO",2320,2719,0,1,"CPIC:CP15:1003:AUTO") #! Record("CPIC:CP15:1003:IL_LATCH",2680,2699,0,1,"CPIC:CP15:1003:IL_LATCH") #! Record("CPIC:CP15:1003:IL_RESET",2502,2719,0,1,"CPIC:CP15:1003:IL_RESET") #! Record("CPIC:CP15:1003:MVAL",3175,2312,0,1,"CPIC:CP15:1003:MVAL") #! Record("CPIC:CP15:1003:PVAL",3360,2312,0,1,"CPIC:CP15:1003:PVAL") #! Record("CPIC:CP15:1003:CMD_OUT",3042,1932,0,1,"CPIC:CP15:1003:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP15 cryoplant number and area in cryoplant\n1003 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP15:1003:TEXT1",1739,2702,0,1,"CPIC:CP15:1003:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP15:1005:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP15:1005:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP15:1005:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP15:1005:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51005_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1005:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51005_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1005:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51005_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1005:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51005_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1005:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51005_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1005:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51005_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1005:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51005_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP15:1005:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51005_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1005:SP_RQST") { field(DESC, "C1PIC51005 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51005_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1005:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51005_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP15:1005:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C1PIC51005") } record(ao, "CPIC:CP15:1005:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51005.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP15:1005:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51005.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP15:1005:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP15:1005:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP15:1005:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51005_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP15:1005:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005_OVH.Mode_Status") } record(bi, "CPIC:CP15:1005:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP15:1005:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1005:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP15:1005:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP15:1005:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP15:1005:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005_OVH.Mode_String") } record(bi, "CPIC:CP15:1005:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP15:1005:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP15:1005:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "C1PV51005") } record(ai, "CPIC:CP15:1005:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP15:1005:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP15:1005:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.MODE") } record(bo, "CPIC:CP15:1005:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51005_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP15:1005:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51005_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP15:1005:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51005_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP15:1005:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP15:1005:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51005.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP15:1005:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1005:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1005:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51005o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP15:1005:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP15:1005:ORBV",2100,2312,0,1,"CPIC:CP15:1005:ORBV") #! Record("CPIC:CP15:1005:OVAL",2280,2312,0,1,"CPIC:CP15:1005:OVAL") #! Record("CPIC:CP15:1005:CVAL",2460,2312,0,1,"CPIC:CP15:1005:CVAL") #! Record("CPIC:CP15:1005:MAX",2122,1932,0,1,"CPIC:CP15:1005:MAX") #! Record("CPIC:CP15:1005:DMIN",2300,1932,0,1,"CPIC:CP15:1005:DMIN") #! Record("CPIC:CP15:1005:DMAX",2479,1932,0,1,"CPIC:CP15:1005:DMAX") #! Record("CPIC:CP15:1005:MDT",2120,2112,0,1,"CPIC:CP15:1005:MDT") #! Record("CPIC:CP15:1005:KP",2300,2106,0,1,"CPIC:CP15:1005:KP") #! Record("CPIC:CP15:1005:KI",2480,2106,0,1,"CPIC:CP15:1005:KI") #! Record("CPIC:CP15:1005:KD",2660,2106,0,1,"CPIC:CP15:1005:KD") #! Record("CPIC:CP15:1005:S",2840,2120,0,1,"CPIC:CP15:1005:S") #! Record("CPIC:CP15:1005:SP_RQST",1760,1932,0,1,"CPIC:CP15:1005:SP_RQST") #! Record("CPIC:CP15:1005:MIN",1945,1932,0,1,"CPIC:CP15:1005:MIN") #! Record("CPIC:CP15:1005:PIDTAG",1740,2462,0,1,"CPIC:CP15:1005:PIDTAG") #! Record("CPIC:CP15:1005:PEVAL",2660,1932,0,1,"CPIC:CP15:1005:PEVAL") #! Record("CPIC:CP15:1005:FSB",2840,1932,0,1,"CPIC:CP15:1005:FSB") #! Record("CPIC:CP15:1005:NOMATCH",3180,2499,0,1,"CPIC:CP15:1005:NOMATCH") #! Record("CPIC:CP15:1005:CHFAULT",3000,2506,0,1,"CPIC:CP15:1005:CHFAULT") #! Record("CPIC:CP15:1005:MANPOS_RQST",1940,2112,0,1,"CPIC:CP15:1005:MANPOS_RQST") #! Record("CPIC:CP15:1005:MODE_STATUS",1920,2314,0,1,"CPIC:CP15:1005:MODE_STATUS") #! Record("CPIC:CP15:1005:INTERLOCK",2460,2499,0,0,"CPIC:CP15:1005:INTERLOCK") #! Record("CPIC:CP15:1005:IVAL",2641,2312,0,1,"CPIC:CP15:1005:IVAL") #! Record("CPIC:CP15:1005:SVAL",2820,2312,0,1,"CPIC:CP15:1005:SVAL") #! Record("CPIC:CP15:1005:MMOD",2100,2506,0,1,"CPIC:CP15:1005:MMOD") #! Record("CPIC:CP15:1005:SMOD",2282,2506,0,1,"CPIC:CP15:1005:SMOD") #! Record("CPIC:CP15:1005:MODE_STRING",1740,2314,0,1,"CPIC:CP15:1005:MODE_STRING") #! Record("CPIC:CP15:1005:PMOD",1922,2479,0,1,"CPIC:CP15:1005:PMOD") #! Record("CPIC:CP15:1005:IMOD",2640,2499,0,1,"CPIC:CP15:1005:IMOD") #! Record("CPIC:CP15:1005:ACTUATOR",1740,2582,0,1,"CPIC:CP15:1005:ACTUATOR") #! Record("CPIC:CP15:1005:AVAL",3000,2312,0,1,"CPIC:CP15:1005:AVAL") #! Record("CPIC:CP15:1005:AMOD",2824,2506,0,1,"CPIC:CP15:1005:AMOD") #! Record("CPIC:CP15:1005:MODE",1760,2134,0,1,"CPIC:CP15:1005:MODE") #! Record("CPIC:CP15:1005:MANUAL",1951,2719,0,1,"CPIC:CP15:1005:MANUAL") #! Record("CPIC:CP15:1005:SEQUENCER",2140,2719,0,1,"CPIC:CP15:1005:SEQUENCER") #! Record("CPIC:CP15:1005:AUTO",2320,2719,0,1,"CPIC:CP15:1005:AUTO") #! Record("CPIC:CP15:1005:IL_LATCH",2680,2699,0,1,"CPIC:CP15:1005:IL_LATCH") #! Record("CPIC:CP15:1005:IL_RESET",2502,2719,0,1,"CPIC:CP15:1005:IL_RESET") #! Record("CPIC:CP15:1005:MVAL",3175,2312,0,1,"CPIC:CP15:1005:MVAL") #! Record("CPIC:CP15:1005:PVAL",3360,2312,0,1,"CPIC:CP15:1005:PVAL") #! Record("CPIC:CP15:1005:CMD_OUT",3042,1932,0,1,"CPIC:CP15:1005:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP15 cryoplant number and area in cryoplant\n1005 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP15:1005:TEXT1",1739,2702,0,1,"CPIC:CP15:1005:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP15:1011:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP15:1011:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP15:1011:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP15:1011:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51011_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1011:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51011_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1011:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51011_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1011:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51011_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1011:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51011_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1011:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51011_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1011:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51011_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP15:1011:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51011_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1011:SP_RQST") { field(DESC, "C1PIC51011 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51011_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1011:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51011_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP15:1011:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C1PIC51011") } record(ao, "CPIC:CP15:1011:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51011.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP15:1011:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51011.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP15:1011:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP15:1011:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP15:1011:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51011_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP15:1011:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011_OVH.Mode_Status") } record(bi, "CPIC:CP15:1011:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP15:1011:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1011:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP15:1011:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP15:1011:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP15:1011:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011_OVH.Mode_String") } record(bi, "CPIC:CP15:1011:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP15:1011:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP15:1011:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "C1PV51011") } record(ai, "CPIC:CP15:1011:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP15:1011:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP15:1011:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.MODE") } record(bo, "CPIC:CP15:1011:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51011_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP15:1011:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51011_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP15:1011:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51011_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP15:1011:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP15:1011:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51011.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP15:1011:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1011:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1011:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51011o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP15:1011:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP15:1011:ORBV",2100,2312,0,1,"CPIC:CP15:1011:ORBV") #! Record("CPIC:CP15:1011:OVAL",2280,2312,0,1,"CPIC:CP15:1011:OVAL") #! Record("CPIC:CP15:1011:CVAL",2460,2312,0,1,"CPIC:CP15:1011:CVAL") #! Record("CPIC:CP15:1011:MAX",2122,1932,0,1,"CPIC:CP15:1011:MAX") #! Record("CPIC:CP15:1011:DMIN",2300,1932,0,1,"CPIC:CP15:1011:DMIN") #! Record("CPIC:CP15:1011:DMAX",2479,1932,0,1,"CPIC:CP15:1011:DMAX") #! Record("CPIC:CP15:1011:MDT",2120,2112,0,1,"CPIC:CP15:1011:MDT") #! Record("CPIC:CP15:1011:KP",2300,2106,0,1,"CPIC:CP15:1011:KP") #! Record("CPIC:CP15:1011:KI",2480,2106,0,1,"CPIC:CP15:1011:KI") #! Record("CPIC:CP15:1011:KD",2660,2106,0,1,"CPIC:CP15:1011:KD") #! Record("CPIC:CP15:1011:S",2840,2120,0,1,"CPIC:CP15:1011:S") #! Record("CPIC:CP15:1011:SP_RQST",1760,1932,0,1,"CPIC:CP15:1011:SP_RQST") #! Record("CPIC:CP15:1011:MIN",1945,1932,0,1,"CPIC:CP15:1011:MIN") #! Record("CPIC:CP15:1011:PIDTAG",1740,2462,0,1,"CPIC:CP15:1011:PIDTAG") #! Record("CPIC:CP15:1011:PEVAL",2660,1932,0,1,"CPIC:CP15:1011:PEVAL") #! Record("CPIC:CP15:1011:FSB",2840,1932,0,1,"CPIC:CP15:1011:FSB") #! Record("CPIC:CP15:1011:NOMATCH",3180,2499,0,1,"CPIC:CP15:1011:NOMATCH") #! Record("CPIC:CP15:1011:CHFAULT",3000,2506,0,1,"CPIC:CP15:1011:CHFAULT") #! Record("CPIC:CP15:1011:MANPOS_RQST",1940,2112,0,1,"CPIC:CP15:1011:MANPOS_RQST") #! Record("CPIC:CP15:1011:MODE_STATUS",1920,2314,0,1,"CPIC:CP15:1011:MODE_STATUS") #! Record("CPIC:CP15:1011:INTERLOCK",2460,2499,0,0,"CPIC:CP15:1011:INTERLOCK") #! Record("CPIC:CP15:1011:IVAL",2641,2312,0,1,"CPIC:CP15:1011:IVAL") #! Record("CPIC:CP15:1011:SVAL",2820,2312,0,1,"CPIC:CP15:1011:SVAL") #! Record("CPIC:CP15:1011:MMOD",2100,2506,0,1,"CPIC:CP15:1011:MMOD") #! Record("CPIC:CP15:1011:SMOD",2282,2506,0,1,"CPIC:CP15:1011:SMOD") #! Record("CPIC:CP15:1011:MODE_STRING",1740,2314,0,1,"CPIC:CP15:1011:MODE_STRING") #! Record("CPIC:CP15:1011:PMOD",1922,2479,0,1,"CPIC:CP15:1011:PMOD") #! Record("CPIC:CP15:1011:IMOD",2640,2499,0,1,"CPIC:CP15:1011:IMOD") #! Record("CPIC:CP15:1011:ACTUATOR",1740,2582,0,1,"CPIC:CP15:1011:ACTUATOR") #! Record("CPIC:CP15:1011:AVAL",3000,2312,0,1,"CPIC:CP15:1011:AVAL") #! Record("CPIC:CP15:1011:AMOD",2824,2506,0,1,"CPIC:CP15:1011:AMOD") #! Record("CPIC:CP15:1011:MODE",1760,2134,0,1,"CPIC:CP15:1011:MODE") #! Record("CPIC:CP15:1011:MANUAL",1951,2719,0,1,"CPIC:CP15:1011:MANUAL") #! Record("CPIC:CP15:1011:SEQUENCER",2140,2719,0,1,"CPIC:CP15:1011:SEQUENCER") #! Record("CPIC:CP15:1011:AUTO",2320,2719,0,1,"CPIC:CP15:1011:AUTO") #! Record("CPIC:CP15:1011:IL_LATCH",2680,2699,0,1,"CPIC:CP15:1011:IL_LATCH") #! Record("CPIC:CP15:1011:IL_RESET",2502,2719,0,1,"CPIC:CP15:1011:IL_RESET") #! Record("CPIC:CP15:1011:MVAL",3175,2312,0,1,"CPIC:CP15:1011:MVAL") #! Record("CPIC:CP15:1011:PVAL",3360,2312,0,1,"CPIC:CP15:1011:PVAL") #! Record("CPIC:CP15:1011:CMD_OUT",3042,1932,0,1,"CPIC:CP15:1011:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP15 cryoplant number and area in cryoplant\n1011 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP15:1011:TEXT1",1739,2702,0,1,"CPIC:CP15:1011:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP15:1013:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP15:1013:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP15:1013:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP15:1013:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51013_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1013:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51013_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1013:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51013_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1013:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51013_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1013:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51013_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1013:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51013_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1013:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51013_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP15:1013:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51013_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1013:SP_RQST") { field(DESC, "C1PIC51013 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51013_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1013:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51013_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP15:1013:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C1PIC51013") } record(ao, "CPIC:CP15:1013:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51013.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP15:1013:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51013.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP15:1013:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP15:1013:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP15:1013:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51013_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP15:1013:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013_OVH.Mode_Status") } record(bi, "CPIC:CP15:1013:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP15:1013:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1013:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP15:1013:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP15:1013:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP15:1013:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013_OVH.Mode_String") } record(bi, "CPIC:CP15:1013:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP15:1013:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP15:1013:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "C1PV51013") } record(ai, "CPIC:CP15:1013:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP15:1013:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP15:1013:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.MODE") } record(bo, "CPIC:CP15:1013:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51013_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP15:1013:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51013_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP15:1013:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51013_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP15:1013:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP15:1013:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51013.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP15:1013:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1013:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1013:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51013o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP15:1013:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP15:1013:ORBV",2100,2312,0,1,"CPIC:CP15:1013:ORBV") #! Record("CPIC:CP15:1013:OVAL",2280,2312,0,1,"CPIC:CP15:1013:OVAL") #! Record("CPIC:CP15:1013:CVAL",2460,2312,0,1,"CPIC:CP15:1013:CVAL") #! Record("CPIC:CP15:1013:MAX",2122,1932,0,1,"CPIC:CP15:1013:MAX") #! Record("CPIC:CP15:1013:DMIN",2300,1932,0,1,"CPIC:CP15:1013:DMIN") #! Record("CPIC:CP15:1013:DMAX",2479,1932,0,1,"CPIC:CP15:1013:DMAX") #! Record("CPIC:CP15:1013:MDT",2120,2112,0,1,"CPIC:CP15:1013:MDT") #! Record("CPIC:CP15:1013:KP",2300,2106,0,1,"CPIC:CP15:1013:KP") #! Record("CPIC:CP15:1013:KI",2480,2106,0,1,"CPIC:CP15:1013:KI") #! Record("CPIC:CP15:1013:KD",2660,2106,0,1,"CPIC:CP15:1013:KD") #! Record("CPIC:CP15:1013:S",2840,2120,0,1,"CPIC:CP15:1013:S") #! Record("CPIC:CP15:1013:SP_RQST",1760,1932,0,1,"CPIC:CP15:1013:SP_RQST") #! Record("CPIC:CP15:1013:MIN",1945,1932,0,1,"CPIC:CP15:1013:MIN") #! Record("CPIC:CP15:1013:PIDTAG",1740,2462,0,1,"CPIC:CP15:1013:PIDTAG") #! Record("CPIC:CP15:1013:PEVAL",2660,1932,0,1,"CPIC:CP15:1013:PEVAL") #! Record("CPIC:CP15:1013:FSB",2840,1932,0,1,"CPIC:CP15:1013:FSB") #! Record("CPIC:CP15:1013:NOMATCH",3180,2499,0,1,"CPIC:CP15:1013:NOMATCH") #! Record("CPIC:CP15:1013:CHFAULT",3000,2506,0,1,"CPIC:CP15:1013:CHFAULT") #! Record("CPIC:CP15:1013:MANPOS_RQST",1940,2112,0,1,"CPIC:CP15:1013:MANPOS_RQST") #! Record("CPIC:CP15:1013:MODE_STATUS",1920,2314,0,1,"CPIC:CP15:1013:MODE_STATUS") #! Record("CPIC:CP15:1013:INTERLOCK",2460,2499,0,0,"CPIC:CP15:1013:INTERLOCK") #! Record("CPIC:CP15:1013:IVAL",2641,2312,0,1,"CPIC:CP15:1013:IVAL") #! Record("CPIC:CP15:1013:SVAL",2820,2312,0,1,"CPIC:CP15:1013:SVAL") #! Record("CPIC:CP15:1013:MMOD",2100,2506,0,1,"CPIC:CP15:1013:MMOD") #! Record("CPIC:CP15:1013:SMOD",2282,2506,0,1,"CPIC:CP15:1013:SMOD") #! Record("CPIC:CP15:1013:MODE_STRING",1740,2314,0,1,"CPIC:CP15:1013:MODE_STRING") #! Record("CPIC:CP15:1013:PMOD",1922,2479,0,1,"CPIC:CP15:1013:PMOD") #! Record("CPIC:CP15:1013:IMOD",2640,2499,0,1,"CPIC:CP15:1013:IMOD") #! Record("CPIC:CP15:1013:ACTUATOR",1740,2582,0,1,"CPIC:CP15:1013:ACTUATOR") #! Record("CPIC:CP15:1013:AVAL",3000,2312,0,1,"CPIC:CP15:1013:AVAL") #! Record("CPIC:CP15:1013:AMOD",2824,2506,0,1,"CPIC:CP15:1013:AMOD") #! Record("CPIC:CP15:1013:MODE",1760,2134,0,1,"CPIC:CP15:1013:MODE") #! Record("CPIC:CP15:1013:MANUAL",1951,2719,0,1,"CPIC:CP15:1013:MANUAL") #! Record("CPIC:CP15:1013:SEQUENCER",2140,2719,0,1,"CPIC:CP15:1013:SEQUENCER") #! Record("CPIC:CP15:1013:AUTO",2320,2719,0,1,"CPIC:CP15:1013:AUTO") #! Record("CPIC:CP15:1013:IL_LATCH",2680,2699,0,1,"CPIC:CP15:1013:IL_LATCH") #! Record("CPIC:CP15:1013:IL_RESET",2502,2719,0,1,"CPIC:CP15:1013:IL_RESET") #! Record("CPIC:CP15:1013:MVAL",3175,2312,0,1,"CPIC:CP15:1013:MVAL") #! Record("CPIC:CP15:1013:PVAL",3360,2312,0,1,"CPIC:CP15:1013:PVAL") #! Record("CPIC:CP15:1013:CMD_OUT",3042,1932,0,1,"CPIC:CP15:1013:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP15 cryoplant number and area in cryoplant\n1013 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP15:1013:TEXT1",1739,2702,0,1,"CPIC:CP15:1013:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP15:1015:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP15:1015:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP15:1015:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP15:1015:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51015_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1015:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51015_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1015:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51015_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1015:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51015_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1015:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51015_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1015:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51015_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1015:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51015_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP15:1015:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51015_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1015:SP_RQST") { field(DESC, "C1PIC51015 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51015_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP15:1015:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51015_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP15:1015:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C1PIC51015") } record(ao, "CPIC:CP15:1015:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51015.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP15:1015:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51015.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP15:1015:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP15:1015:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP15:1015:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C1PV51015_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP15:1015:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015_OVH.Mode_Status") } record(bi, "CPIC:CP15:1015:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP15:1015:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1015:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP15:1015:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP15:1015:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP15:1015:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015_OVH.Mode_String") } record(bi, "CPIC:CP15:1015:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP15:1015:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP15:1015:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "C1PV51015") } record(ai, "CPIC:CP15:1015:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP15:1015:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP15:1015:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.MODE") } record(bo, "CPIC:CP15:1015:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51015_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP15:1015:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51015_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP15:1015:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51015_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP15:1015:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP15:1015:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C1PV51015.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP15:1015:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1015:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP15:1015:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C1PV51015o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP15:1015:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP15:1015:ORBV",2100,2312,0,1,"CPIC:CP15:1015:ORBV") #! Record("CPIC:CP15:1015:OVAL",2280,2312,0,1,"CPIC:CP15:1015:OVAL") #! Record("CPIC:CP15:1015:CVAL",2460,2312,0,1,"CPIC:CP15:1015:CVAL") #! Record("CPIC:CP15:1015:MAX",2122,1932,0,1,"CPIC:CP15:1015:MAX") #! Record("CPIC:CP15:1015:DMIN",2300,1932,0,1,"CPIC:CP15:1015:DMIN") #! Record("CPIC:CP15:1015:DMAX",2479,1932,0,1,"CPIC:CP15:1015:DMAX") #! Record("CPIC:CP15:1015:MDT",2120,2112,0,1,"CPIC:CP15:1015:MDT") #! Record("CPIC:CP15:1015:KP",2300,2106,0,1,"CPIC:CP15:1015:KP") #! Record("CPIC:CP15:1015:KI",2480,2106,0,1,"CPIC:CP15:1015:KI") #! Record("CPIC:CP15:1015:KD",2660,2106,0,1,"CPIC:CP15:1015:KD") #! Record("CPIC:CP15:1015:S",2840,2120,0,1,"CPIC:CP15:1015:S") #! Record("CPIC:CP15:1015:SP_RQST",1760,1932,0,1,"CPIC:CP15:1015:SP_RQST") #! Record("CPIC:CP15:1015:MIN",1945,1932,0,1,"CPIC:CP15:1015:MIN") #! Record("CPIC:CP15:1015:PIDTAG",1740,2462,0,1,"CPIC:CP15:1015:PIDTAG") #! Record("CPIC:CP15:1015:PEVAL",2660,1932,0,1,"CPIC:CP15:1015:PEVAL") #! Record("CPIC:CP15:1015:FSB",2840,1932,0,1,"CPIC:CP15:1015:FSB") #! Record("CPIC:CP15:1015:NOMATCH",3180,2499,0,1,"CPIC:CP15:1015:NOMATCH") #! Record("CPIC:CP15:1015:CHFAULT",3000,2506,0,1,"CPIC:CP15:1015:CHFAULT") #! Record("CPIC:CP15:1015:MANPOS_RQST",1940,2112,0,1,"CPIC:CP15:1015:MANPOS_RQST") #! Record("CPIC:CP15:1015:MODE_STATUS",1920,2314,0,1,"CPIC:CP15:1015:MODE_STATUS") #! Record("CPIC:CP15:1015:INTERLOCK",2460,2499,0,0,"CPIC:CP15:1015:INTERLOCK") #! Record("CPIC:CP15:1015:IVAL",2641,2312,0,1,"CPIC:CP15:1015:IVAL") #! Record("CPIC:CP15:1015:SVAL",2820,2312,0,1,"CPIC:CP15:1015:SVAL") #! Record("CPIC:CP15:1015:MMOD",2100,2506,0,1,"CPIC:CP15:1015:MMOD") #! Record("CPIC:CP15:1015:SMOD",2282,2506,0,1,"CPIC:CP15:1015:SMOD") #! Record("CPIC:CP15:1015:MODE_STRING",1740,2314,0,1,"CPIC:CP15:1015:MODE_STRING") #! Record("CPIC:CP15:1015:PMOD",1922,2479,0,1,"CPIC:CP15:1015:PMOD") #! Record("CPIC:CP15:1015:IMOD",2640,2499,0,1,"CPIC:CP15:1015:IMOD") #! Record("CPIC:CP15:1015:ACTUATOR",1740,2582,0,1,"CPIC:CP15:1015:ACTUATOR") #! Record("CPIC:CP15:1015:AVAL",3000,2312,0,1,"CPIC:CP15:1015:AVAL") #! Record("CPIC:CP15:1015:AMOD",2824,2506,0,1,"CPIC:CP15:1015:AMOD") #! Record("CPIC:CP15:1015:MODE",1760,2134,0,1,"CPIC:CP15:1015:MODE") #! Record("CPIC:CP15:1015:MANUAL",1951,2719,0,1,"CPIC:CP15:1015:MANUAL") #! Record("CPIC:CP15:1015:SEQUENCER",2140,2719,0,1,"CPIC:CP15:1015:SEQUENCER") #! Record("CPIC:CP15:1015:AUTO",2320,2719,0,1,"CPIC:CP15:1015:AUTO") #! Record("CPIC:CP15:1015:IL_LATCH",2680,2699,0,1,"CPIC:CP15:1015:IL_LATCH") #! Record("CPIC:CP15:1015:IL_RESET",2502,2719,0,1,"CPIC:CP15:1015:IL_RESET") #! Record("CPIC:CP15:1015:MVAL",3175,2312,0,1,"CPIC:CP15:1015:MVAL") #! Record("CPIC:CP15:1015:PVAL",3360,2312,0,1,"CPIC:CP15:1015:PVAL") #! Record("CPIC:CP15:1015:CMD_OUT",3042,1932,0,1,"CPIC:CP15:1015:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP15 cryoplant number and area in cryoplant\n1015 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP15:1015:TEXT1",1739,2702,0,1,"CPIC:CP15:1015:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP25:1001:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP25:1001:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP25:1001:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP25:1001:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51001_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1001:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51001_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1001:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51001_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1001:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51001_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1001:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51001_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1001:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51001_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1001:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51001_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP25:1001:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51001_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1001:SP_RQST") { field(DESC, "C2PIC51001 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51001_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1001:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51001_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP25:1001:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C2PIC51001") } record(ao, "CPIC:CP25:1001:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51001.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP25:1001:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51001.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP25:1001:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP25:1001:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP25:1001:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51001_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP25:1001:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001_OVH.Mode_Status") } record(bi, "CPIC:CP25:1001:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP25:1001:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1001:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP25:1001:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP25:1001:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP25:1001:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001_OVH.Mode_String") } record(bi, "CPIC:CP25:1001:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP25:1001:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP25:1001:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "C2PV51001") } record(ai, "CPIC:CP25:1001:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP25:1001:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP25:1001:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.MODE") } record(bo, "CPIC:CP25:1001:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51001_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP25:1001:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51001_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP25:1001:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51001_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP25:1001:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP25:1001:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51001.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP25:1001:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1001:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1001:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51001o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP25:1001:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP25:1001:ORBV",2100,2312,0,1,"CPIC:CP25:1001:ORBV") #! Record("CPIC:CP25:1001:OVAL",2280,2312,0,1,"CPIC:CP25:1001:OVAL") #! Record("CPIC:CP25:1001:CVAL",2460,2312,0,1,"CPIC:CP25:1001:CVAL") #! Record("CPIC:CP25:1001:MAX",2122,1932,0,1,"CPIC:CP25:1001:MAX") #! Record("CPIC:CP25:1001:DMIN",2300,1932,0,1,"CPIC:CP25:1001:DMIN") #! Record("CPIC:CP25:1001:DMAX",2479,1932,0,1,"CPIC:CP25:1001:DMAX") #! Record("CPIC:CP25:1001:MDT",2120,2112,0,1,"CPIC:CP25:1001:MDT") #! Record("CPIC:CP25:1001:KP",2300,2106,0,1,"CPIC:CP25:1001:KP") #! Record("CPIC:CP25:1001:KI",2480,2106,0,1,"CPIC:CP25:1001:KI") #! Record("CPIC:CP25:1001:KD",2660,2106,0,1,"CPIC:CP25:1001:KD") #! Record("CPIC:CP25:1001:S",2840,2120,0,1,"CPIC:CP25:1001:S") #! Record("CPIC:CP25:1001:SP_RQST",1760,1932,0,1,"CPIC:CP25:1001:SP_RQST") #! Record("CPIC:CP25:1001:MIN",1945,1932,0,1,"CPIC:CP25:1001:MIN") #! Record("CPIC:CP25:1001:PIDTAG",1740,2462,0,1,"CPIC:CP25:1001:PIDTAG") #! Record("CPIC:CP25:1001:PEVAL",2660,1932,0,1,"CPIC:CP25:1001:PEVAL") #! Record("CPIC:CP25:1001:FSB",2840,1932,0,1,"CPIC:CP25:1001:FSB") #! Record("CPIC:CP25:1001:NOMATCH",3180,2499,0,1,"CPIC:CP25:1001:NOMATCH") #! Record("CPIC:CP25:1001:CHFAULT",3000,2506,0,1,"CPIC:CP25:1001:CHFAULT") #! Record("CPIC:CP25:1001:MANPOS_RQST",1940,2112,0,1,"CPIC:CP25:1001:MANPOS_RQST") #! Record("CPIC:CP25:1001:MODE_STATUS",1920,2314,0,1,"CPIC:CP25:1001:MODE_STATUS") #! Record("CPIC:CP25:1001:INTERLOCK",2460,2499,0,0,"CPIC:CP25:1001:INTERLOCK") #! Record("CPIC:CP25:1001:IVAL",2641,2312,0,1,"CPIC:CP25:1001:IVAL") #! Record("CPIC:CP25:1001:SVAL",2820,2312,0,1,"CPIC:CP25:1001:SVAL") #! Record("CPIC:CP25:1001:MMOD",2100,2506,0,1,"CPIC:CP25:1001:MMOD") #! Record("CPIC:CP25:1001:SMOD",2282,2506,0,1,"CPIC:CP25:1001:SMOD") #! Record("CPIC:CP25:1001:MODE_STRING",1740,2314,0,1,"CPIC:CP25:1001:MODE_STRING") #! Record("CPIC:CP25:1001:PMOD",1922,2479,0,1,"CPIC:CP25:1001:PMOD") #! Record("CPIC:CP25:1001:IMOD",2640,2499,0,1,"CPIC:CP25:1001:IMOD") #! Record("CPIC:CP25:1001:ACTUATOR",1740,2582,0,1,"CPIC:CP25:1001:ACTUATOR") #! Record("CPIC:CP25:1001:AVAL",3000,2312,0,1,"CPIC:CP25:1001:AVAL") #! Record("CPIC:CP25:1001:AMOD",2824,2506,0,1,"CPIC:CP25:1001:AMOD") #! Record("CPIC:CP25:1001:MODE",1760,2134,0,1,"CPIC:CP25:1001:MODE") #! Record("CPIC:CP25:1001:MANUAL",1951,2719,0,1,"CPIC:CP25:1001:MANUAL") #! Record("CPIC:CP25:1001:SEQUENCER",2140,2719,0,1,"CPIC:CP25:1001:SEQUENCER") #! Record("CPIC:CP25:1001:AUTO",2320,2719,0,1,"CPIC:CP25:1001:AUTO") #! Record("CPIC:CP25:1001:IL_LATCH",2680,2699,0,1,"CPIC:CP25:1001:IL_LATCH") #! Record("CPIC:CP25:1001:IL_RESET",2502,2719,0,1,"CPIC:CP25:1001:IL_RESET") #! Record("CPIC:CP25:1001:MVAL",3175,2312,0,1,"CPIC:CP25:1001:MVAL") #! Record("CPIC:CP25:1001:PVAL",3360,2312,0,1,"CPIC:CP25:1001:PVAL") #! Record("CPIC:CP25:1001:CMD_OUT",3042,1932,0,1,"CPIC:CP25:1001:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP25 cryoplant number and area in cryoplant\n1001 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP25:1001:TEXT1",1739,2702,0,1,"CPIC:CP25:1001:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP25:1003:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP25:1003:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP25:1003:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP25:1003:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51003_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1003:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51003_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1003:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51003_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1003:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51003_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1003:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51003_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1003:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51003_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1003:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51003_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP25:1003:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51003_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1003:SP_RQST") { field(DESC, "C2PIC51003 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51003_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1003:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51003_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP25:1003:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C2PIC51003") } record(ao, "CPIC:CP25:1003:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51003.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP25:1003:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51003.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP25:1003:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP25:1003:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP25:1003:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51003_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP25:1003:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003_OVH.Mode_Status") } record(bi, "CPIC:CP25:1003:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP25:1003:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1003:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP25:1003:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP25:1003:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP25:1003:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003_OVH.Mode_String") } record(bi, "CPIC:CP25:1003:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP25:1003:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP25:1003:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "C2PV51003") } record(ai, "CPIC:CP25:1003:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP25:1003:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP25:1003:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.MODE") } record(bo, "CPIC:CP25:1003:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51003_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP25:1003:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51003_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP25:1003:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51003_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP25:1003:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP25:1003:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51003.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP25:1003:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1003:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1003:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51003o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP25:1003:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP25:1003:ORBV",2100,2312,0,1,"CPIC:CP25:1003:ORBV") #! Record("CPIC:CP25:1003:OVAL",2280,2312,0,1,"CPIC:CP25:1003:OVAL") #! Record("CPIC:CP25:1003:CVAL",2460,2312,0,1,"CPIC:CP25:1003:CVAL") #! Record("CPIC:CP25:1003:MAX",2122,1932,0,1,"CPIC:CP25:1003:MAX") #! Record("CPIC:CP25:1003:DMIN",2300,1932,0,1,"CPIC:CP25:1003:DMIN") #! Record("CPIC:CP25:1003:DMAX",2479,1932,0,1,"CPIC:CP25:1003:DMAX") #! Record("CPIC:CP25:1003:MDT",2120,2112,0,1,"CPIC:CP25:1003:MDT") #! Record("CPIC:CP25:1003:KP",2300,2106,0,1,"CPIC:CP25:1003:KP") #! Record("CPIC:CP25:1003:KI",2480,2106,0,1,"CPIC:CP25:1003:KI") #! Record("CPIC:CP25:1003:KD",2660,2106,0,1,"CPIC:CP25:1003:KD") #! Record("CPIC:CP25:1003:S",2840,2120,0,1,"CPIC:CP25:1003:S") #! Record("CPIC:CP25:1003:SP_RQST",1760,1932,0,1,"CPIC:CP25:1003:SP_RQST") #! Record("CPIC:CP25:1003:MIN",1945,1932,0,1,"CPIC:CP25:1003:MIN") #! Record("CPIC:CP25:1003:PIDTAG",1740,2462,0,1,"CPIC:CP25:1003:PIDTAG") #! Record("CPIC:CP25:1003:PEVAL",2660,1932,0,1,"CPIC:CP25:1003:PEVAL") #! Record("CPIC:CP25:1003:FSB",2840,1932,0,1,"CPIC:CP25:1003:FSB") #! Record("CPIC:CP25:1003:NOMATCH",3180,2499,0,1,"CPIC:CP25:1003:NOMATCH") #! Record("CPIC:CP25:1003:CHFAULT",3000,2506,0,1,"CPIC:CP25:1003:CHFAULT") #! Record("CPIC:CP25:1003:MANPOS_RQST",1940,2112,0,1,"CPIC:CP25:1003:MANPOS_RQST") #! Record("CPIC:CP25:1003:MODE_STATUS",1920,2314,0,1,"CPIC:CP25:1003:MODE_STATUS") #! Record("CPIC:CP25:1003:INTERLOCK",2460,2499,0,0,"CPIC:CP25:1003:INTERLOCK") #! Record("CPIC:CP25:1003:IVAL",2641,2312,0,1,"CPIC:CP25:1003:IVAL") #! Record("CPIC:CP25:1003:SVAL",2820,2312,0,1,"CPIC:CP25:1003:SVAL") #! Record("CPIC:CP25:1003:MMOD",2100,2506,0,1,"CPIC:CP25:1003:MMOD") #! Record("CPIC:CP25:1003:SMOD",2282,2506,0,1,"CPIC:CP25:1003:SMOD") #! Record("CPIC:CP25:1003:MODE_STRING",1740,2314,0,1,"CPIC:CP25:1003:MODE_STRING") #! Record("CPIC:CP25:1003:PMOD",1922,2479,0,1,"CPIC:CP25:1003:PMOD") #! Record("CPIC:CP25:1003:IMOD",2640,2499,0,1,"CPIC:CP25:1003:IMOD") #! Record("CPIC:CP25:1003:ACTUATOR",1740,2582,0,1,"CPIC:CP25:1003:ACTUATOR") #! Record("CPIC:CP25:1003:AVAL",3000,2312,0,1,"CPIC:CP25:1003:AVAL") #! Record("CPIC:CP25:1003:AMOD",2824,2506,0,1,"CPIC:CP25:1003:AMOD") #! Record("CPIC:CP25:1003:MODE",1760,2134,0,1,"CPIC:CP25:1003:MODE") #! Record("CPIC:CP25:1003:MANUAL",1951,2719,0,1,"CPIC:CP25:1003:MANUAL") #! Record("CPIC:CP25:1003:SEQUENCER",2140,2719,0,1,"CPIC:CP25:1003:SEQUENCER") #! Record("CPIC:CP25:1003:AUTO",2320,2719,0,1,"CPIC:CP25:1003:AUTO") #! Record("CPIC:CP25:1003:IL_LATCH",2680,2699,0,1,"CPIC:CP25:1003:IL_LATCH") #! Record("CPIC:CP25:1003:IL_RESET",2502,2719,0,1,"CPIC:CP25:1003:IL_RESET") #! Record("CPIC:CP25:1003:MVAL",3175,2312,0,1,"CPIC:CP25:1003:MVAL") #! Record("CPIC:CP25:1003:PVAL",3360,2312,0,1,"CPIC:CP25:1003:PVAL") #! Record("CPIC:CP25:1003:CMD_OUT",3042,1932,0,1,"CPIC:CP25:1003:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP25 cryoplant number and area in cryoplant\n1003 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP25:1003:TEXT1",1739,2702,0,1,"CPIC:CP25:1003:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP25:1005:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP25:1005:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP25:1005:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP25:1005:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51005_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1005:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51005_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1005:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51005_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1005:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51005_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1005:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51005_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1005:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51005_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1005:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51005_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP25:1005:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51005_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1005:SP_RQST") { field(DESC, "C2PIC51005 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51005_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1005:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51005_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP25:1005:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C2PIC51005") } record(ao, "CPIC:CP25:1005:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51005.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP25:1005:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51005.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP25:1005:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP25:1005:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP25:1005:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51005_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP25:1005:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005_OVH.Mode_Status") } record(bi, "CPIC:CP25:1005:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP25:1005:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1005:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP25:1005:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP25:1005:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP25:1005:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005_OVH.Mode_String") } record(bi, "CPIC:CP25:1005:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP25:1005:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP25:1005:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "C2PV51005") } record(ai, "CPIC:CP25:1005:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP25:1005:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP25:1005:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.MODE") } record(bo, "CPIC:CP25:1005:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51005_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP25:1005:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51005_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP25:1005:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51005_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP25:1005:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP25:1005:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51005.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP25:1005:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1005:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1005:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51005o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP25:1005:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP25:1005:ORBV",2100,2312,0,1,"CPIC:CP25:1005:ORBV") #! Record("CPIC:CP25:1005:OVAL",2280,2312,0,1,"CPIC:CP25:1005:OVAL") #! Record("CPIC:CP25:1005:CVAL",2460,2312,0,1,"CPIC:CP25:1005:CVAL") #! Record("CPIC:CP25:1005:MAX",2122,1932,0,1,"CPIC:CP25:1005:MAX") #! Record("CPIC:CP25:1005:DMIN",2300,1932,0,1,"CPIC:CP25:1005:DMIN") #! Record("CPIC:CP25:1005:DMAX",2479,1932,0,1,"CPIC:CP25:1005:DMAX") #! Record("CPIC:CP25:1005:MDT",2120,2112,0,1,"CPIC:CP25:1005:MDT") #! Record("CPIC:CP25:1005:KP",2300,2106,0,1,"CPIC:CP25:1005:KP") #! Record("CPIC:CP25:1005:KI",2480,2106,0,1,"CPIC:CP25:1005:KI") #! Record("CPIC:CP25:1005:KD",2660,2106,0,1,"CPIC:CP25:1005:KD") #! Record("CPIC:CP25:1005:S",2840,2120,0,1,"CPIC:CP25:1005:S") #! Record("CPIC:CP25:1005:SP_RQST",1760,1932,0,1,"CPIC:CP25:1005:SP_RQST") #! Record("CPIC:CP25:1005:MIN",1945,1932,0,1,"CPIC:CP25:1005:MIN") #! Record("CPIC:CP25:1005:PIDTAG",1740,2462,0,1,"CPIC:CP25:1005:PIDTAG") #! Record("CPIC:CP25:1005:PEVAL",2660,1932,0,1,"CPIC:CP25:1005:PEVAL") #! Record("CPIC:CP25:1005:FSB",2840,1932,0,1,"CPIC:CP25:1005:FSB") #! Record("CPIC:CP25:1005:NOMATCH",3180,2499,0,1,"CPIC:CP25:1005:NOMATCH") #! Record("CPIC:CP25:1005:CHFAULT",3000,2506,0,1,"CPIC:CP25:1005:CHFAULT") #! Record("CPIC:CP25:1005:MANPOS_RQST",1940,2112,0,1,"CPIC:CP25:1005:MANPOS_RQST") #! Record("CPIC:CP25:1005:MODE_STATUS",1920,2314,0,1,"CPIC:CP25:1005:MODE_STATUS") #! Record("CPIC:CP25:1005:INTERLOCK",2460,2499,0,0,"CPIC:CP25:1005:INTERLOCK") #! Record("CPIC:CP25:1005:IVAL",2641,2312,0,1,"CPIC:CP25:1005:IVAL") #! Record("CPIC:CP25:1005:SVAL",2820,2312,0,1,"CPIC:CP25:1005:SVAL") #! Record("CPIC:CP25:1005:MMOD",2100,2506,0,1,"CPIC:CP25:1005:MMOD") #! Record("CPIC:CP25:1005:SMOD",2282,2506,0,1,"CPIC:CP25:1005:SMOD") #! Record("CPIC:CP25:1005:MODE_STRING",1740,2314,0,1,"CPIC:CP25:1005:MODE_STRING") #! Record("CPIC:CP25:1005:PMOD",1922,2479,0,1,"CPIC:CP25:1005:PMOD") #! Record("CPIC:CP25:1005:IMOD",2640,2499,0,1,"CPIC:CP25:1005:IMOD") #! Record("CPIC:CP25:1005:ACTUATOR",1740,2582,0,1,"CPIC:CP25:1005:ACTUATOR") #! Record("CPIC:CP25:1005:AVAL",3000,2312,0,1,"CPIC:CP25:1005:AVAL") #! Record("CPIC:CP25:1005:AMOD",2824,2506,0,1,"CPIC:CP25:1005:AMOD") #! Record("CPIC:CP25:1005:MODE",1760,2134,0,1,"CPIC:CP25:1005:MODE") #! Record("CPIC:CP25:1005:MANUAL",1951,2719,0,1,"CPIC:CP25:1005:MANUAL") #! Record("CPIC:CP25:1005:SEQUENCER",2140,2719,0,1,"CPIC:CP25:1005:SEQUENCER") #! Record("CPIC:CP25:1005:AUTO",2320,2719,0,1,"CPIC:CP25:1005:AUTO") #! Record("CPIC:CP25:1005:IL_LATCH",2680,2699,0,1,"CPIC:CP25:1005:IL_LATCH") #! Record("CPIC:CP25:1005:IL_RESET",2502,2719,0,1,"CPIC:CP25:1005:IL_RESET") #! Record("CPIC:CP25:1005:MVAL",3175,2312,0,1,"CPIC:CP25:1005:MVAL") #! Record("CPIC:CP25:1005:PVAL",3360,2312,0,1,"CPIC:CP25:1005:PVAL") #! Record("CPIC:CP25:1005:CMD_OUT",3042,1932,0,1,"CPIC:CP25:1005:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP25 cryoplant number and area in cryoplant\n1005 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP25:1005:TEXT1",1739,2702,0,1,"CPIC:CP25:1005:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP25:1011:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP25:1011:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP25:1011:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP25:1011:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51011_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1011:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51011_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1011:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51011_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1011:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51011_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1011:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51011_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1011:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51011_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1011:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51011_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP25:1011:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51011_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1011:SP_RQST") { field(DESC, "C2PIC51011 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51011_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1011:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51011_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP25:1011:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C2PIC51011") } record(ao, "CPIC:CP25:1011:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51011.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP25:1011:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51011.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP25:1011:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP25:1011:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP25:1011:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51011_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP25:1011:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011_OVH.Mode_Status") } record(bi, "CPIC:CP25:1011:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP25:1011:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1011:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP25:1011:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP25:1011:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP25:1011:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011_OVH.Mode_String") } record(bi, "CPIC:CP25:1011:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP25:1011:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP25:1011:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "C2PV51011") } record(ai, "CPIC:CP25:1011:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP25:1011:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP25:1011:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.MODE") } record(bo, "CPIC:CP25:1011:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51011_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP25:1011:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51011_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP25:1011:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51011_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP25:1011:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP25:1011:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51011.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP25:1011:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1011:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1011:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51011o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP25:1011:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP25:1011:ORBV",2100,2312,0,1,"CPIC:CP25:1011:ORBV") #! Record("CPIC:CP25:1011:OVAL",2280,2312,0,1,"CPIC:CP25:1011:OVAL") #! Record("CPIC:CP25:1011:CVAL",2460,2312,0,1,"CPIC:CP25:1011:CVAL") #! Record("CPIC:CP25:1011:MAX",2122,1932,0,1,"CPIC:CP25:1011:MAX") #! Record("CPIC:CP25:1011:DMIN",2300,1932,0,1,"CPIC:CP25:1011:DMIN") #! Record("CPIC:CP25:1011:DMAX",2479,1932,0,1,"CPIC:CP25:1011:DMAX") #! Record("CPIC:CP25:1011:MDT",2120,2112,0,1,"CPIC:CP25:1011:MDT") #! Record("CPIC:CP25:1011:KP",2300,2106,0,1,"CPIC:CP25:1011:KP") #! Record("CPIC:CP25:1011:KI",2480,2106,0,1,"CPIC:CP25:1011:KI") #! Record("CPIC:CP25:1011:KD",2660,2106,0,1,"CPIC:CP25:1011:KD") #! Record("CPIC:CP25:1011:S",2840,2120,0,1,"CPIC:CP25:1011:S") #! Record("CPIC:CP25:1011:SP_RQST",1760,1932,0,1,"CPIC:CP25:1011:SP_RQST") #! Record("CPIC:CP25:1011:MIN",1945,1932,0,1,"CPIC:CP25:1011:MIN") #! Record("CPIC:CP25:1011:PIDTAG",1740,2462,0,1,"CPIC:CP25:1011:PIDTAG") #! Record("CPIC:CP25:1011:PEVAL",2660,1932,0,1,"CPIC:CP25:1011:PEVAL") #! Record("CPIC:CP25:1011:FSB",2840,1932,0,1,"CPIC:CP25:1011:FSB") #! Record("CPIC:CP25:1011:NOMATCH",3180,2499,0,1,"CPIC:CP25:1011:NOMATCH") #! Record("CPIC:CP25:1011:CHFAULT",3000,2506,0,1,"CPIC:CP25:1011:CHFAULT") #! Record("CPIC:CP25:1011:MANPOS_RQST",1940,2112,0,1,"CPIC:CP25:1011:MANPOS_RQST") #! Record("CPIC:CP25:1011:MODE_STATUS",1920,2314,0,1,"CPIC:CP25:1011:MODE_STATUS") #! Record("CPIC:CP25:1011:INTERLOCK",2460,2499,0,0,"CPIC:CP25:1011:INTERLOCK") #! Record("CPIC:CP25:1011:IVAL",2641,2312,0,1,"CPIC:CP25:1011:IVAL") #! Record("CPIC:CP25:1011:SVAL",2820,2312,0,1,"CPIC:CP25:1011:SVAL") #! Record("CPIC:CP25:1011:MMOD",2100,2506,0,1,"CPIC:CP25:1011:MMOD") #! Record("CPIC:CP25:1011:SMOD",2282,2506,0,1,"CPIC:CP25:1011:SMOD") #! Record("CPIC:CP25:1011:MODE_STRING",1740,2314,0,1,"CPIC:CP25:1011:MODE_STRING") #! Record("CPIC:CP25:1011:PMOD",1922,2479,0,1,"CPIC:CP25:1011:PMOD") #! Record("CPIC:CP25:1011:IMOD",2640,2499,0,1,"CPIC:CP25:1011:IMOD") #! Record("CPIC:CP25:1011:ACTUATOR",1740,2582,0,1,"CPIC:CP25:1011:ACTUATOR") #! Record("CPIC:CP25:1011:AVAL",3000,2312,0,1,"CPIC:CP25:1011:AVAL") #! Record("CPIC:CP25:1011:AMOD",2824,2506,0,1,"CPIC:CP25:1011:AMOD") #! Record("CPIC:CP25:1011:MODE",1760,2134,0,1,"CPIC:CP25:1011:MODE") #! Record("CPIC:CP25:1011:MANUAL",1951,2719,0,1,"CPIC:CP25:1011:MANUAL") #! Record("CPIC:CP25:1011:SEQUENCER",2140,2719,0,1,"CPIC:CP25:1011:SEQUENCER") #! Record("CPIC:CP25:1011:AUTO",2320,2719,0,1,"CPIC:CP25:1011:AUTO") #! Record("CPIC:CP25:1011:IL_LATCH",2680,2699,0,1,"CPIC:CP25:1011:IL_LATCH") #! Record("CPIC:CP25:1011:IL_RESET",2502,2719,0,1,"CPIC:CP25:1011:IL_RESET") #! Record("CPIC:CP25:1011:MVAL",3175,2312,0,1,"CPIC:CP25:1011:MVAL") #! Record("CPIC:CP25:1011:PVAL",3360,2312,0,1,"CPIC:CP25:1011:PVAL") #! Record("CPIC:CP25:1011:CMD_OUT",3042,1932,0,1,"CPIC:CP25:1011:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP25 cryoplant number and area in cryoplant\n1011 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP25:1011:TEXT1",1739,2702,0,1,"CPIC:CP25:1011:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP25:1013:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP25:1013:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP25:1013:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP25:1013:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51013_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1013:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51013_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1013:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51013_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1013:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51013_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1013:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51013_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1013:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51013_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1013:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51013_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP25:1013:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51013_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1013:SP_RQST") { field(DESC, "C2PIC51013 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51013_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1013:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51013_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP25:1013:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C2PIC51013") } record(ao, "CPIC:CP25:1013:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51013.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP25:1013:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51013.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP25:1013:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP25:1013:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP25:1013:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51013_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP25:1013:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013_OVH.Mode_Status") } record(bi, "CPIC:CP25:1013:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP25:1013:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1013:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP25:1013:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP25:1013:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP25:1013:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013_OVH.Mode_String") } record(bi, "CPIC:CP25:1013:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP25:1013:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP25:1013:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "C2PV51013") } record(ai, "CPIC:CP25:1013:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP25:1013:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP25:1013:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.MODE") } record(bo, "CPIC:CP25:1013:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51013_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP25:1013:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51013_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP25:1013:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51013_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP25:1013:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP25:1013:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51013.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP25:1013:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1013:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1013:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51013o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP25:1013:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP25:1013:ORBV",2100,2312,0,1,"CPIC:CP25:1013:ORBV") #! Record("CPIC:CP25:1013:OVAL",2280,2312,0,1,"CPIC:CP25:1013:OVAL") #! Record("CPIC:CP25:1013:CVAL",2460,2312,0,1,"CPIC:CP25:1013:CVAL") #! Record("CPIC:CP25:1013:MAX",2122,1932,0,1,"CPIC:CP25:1013:MAX") #! Record("CPIC:CP25:1013:DMIN",2300,1932,0,1,"CPIC:CP25:1013:DMIN") #! Record("CPIC:CP25:1013:DMAX",2479,1932,0,1,"CPIC:CP25:1013:DMAX") #! Record("CPIC:CP25:1013:MDT",2120,2112,0,1,"CPIC:CP25:1013:MDT") #! Record("CPIC:CP25:1013:KP",2300,2106,0,1,"CPIC:CP25:1013:KP") #! Record("CPIC:CP25:1013:KI",2480,2106,0,1,"CPIC:CP25:1013:KI") #! Record("CPIC:CP25:1013:KD",2660,2106,0,1,"CPIC:CP25:1013:KD") #! Record("CPIC:CP25:1013:S",2840,2120,0,1,"CPIC:CP25:1013:S") #! Record("CPIC:CP25:1013:SP_RQST",1760,1932,0,1,"CPIC:CP25:1013:SP_RQST") #! Record("CPIC:CP25:1013:MIN",1945,1932,0,1,"CPIC:CP25:1013:MIN") #! Record("CPIC:CP25:1013:PIDTAG",1740,2462,0,1,"CPIC:CP25:1013:PIDTAG") #! Record("CPIC:CP25:1013:PEVAL",2660,1932,0,1,"CPIC:CP25:1013:PEVAL") #! Record("CPIC:CP25:1013:FSB",2840,1932,0,1,"CPIC:CP25:1013:FSB") #! Record("CPIC:CP25:1013:NOMATCH",3180,2499,0,1,"CPIC:CP25:1013:NOMATCH") #! Record("CPIC:CP25:1013:CHFAULT",3000,2506,0,1,"CPIC:CP25:1013:CHFAULT") #! Record("CPIC:CP25:1013:MANPOS_RQST",1940,2112,0,1,"CPIC:CP25:1013:MANPOS_RQST") #! Record("CPIC:CP25:1013:MODE_STATUS",1920,2314,0,1,"CPIC:CP25:1013:MODE_STATUS") #! Record("CPIC:CP25:1013:INTERLOCK",2460,2499,0,0,"CPIC:CP25:1013:INTERLOCK") #! Record("CPIC:CP25:1013:IVAL",2641,2312,0,1,"CPIC:CP25:1013:IVAL") #! Record("CPIC:CP25:1013:SVAL",2820,2312,0,1,"CPIC:CP25:1013:SVAL") #! Record("CPIC:CP25:1013:MMOD",2100,2506,0,1,"CPIC:CP25:1013:MMOD") #! Record("CPIC:CP25:1013:SMOD",2282,2506,0,1,"CPIC:CP25:1013:SMOD") #! Record("CPIC:CP25:1013:MODE_STRING",1740,2314,0,1,"CPIC:CP25:1013:MODE_STRING") #! Record("CPIC:CP25:1013:PMOD",1922,2479,0,1,"CPIC:CP25:1013:PMOD") #! Record("CPIC:CP25:1013:IMOD",2640,2499,0,1,"CPIC:CP25:1013:IMOD") #! Record("CPIC:CP25:1013:ACTUATOR",1740,2582,0,1,"CPIC:CP25:1013:ACTUATOR") #! Record("CPIC:CP25:1013:AVAL",3000,2312,0,1,"CPIC:CP25:1013:AVAL") #! Record("CPIC:CP25:1013:AMOD",2824,2506,0,1,"CPIC:CP25:1013:AMOD") #! Record("CPIC:CP25:1013:MODE",1760,2134,0,1,"CPIC:CP25:1013:MODE") #! Record("CPIC:CP25:1013:MANUAL",1951,2719,0,1,"CPIC:CP25:1013:MANUAL") #! Record("CPIC:CP25:1013:SEQUENCER",2140,2719,0,1,"CPIC:CP25:1013:SEQUENCER") #! Record("CPIC:CP25:1013:AUTO",2320,2719,0,1,"CPIC:CP25:1013:AUTO") #! Record("CPIC:CP25:1013:IL_LATCH",2680,2699,0,1,"CPIC:CP25:1013:IL_LATCH") #! Record("CPIC:CP25:1013:IL_RESET",2502,2719,0,1,"CPIC:CP25:1013:IL_RESET") #! Record("CPIC:CP25:1013:MVAL",3175,2312,0,1,"CPIC:CP25:1013:MVAL") #! Record("CPIC:CP25:1013:PVAL",3360,2312,0,1,"CPIC:CP25:1013:PVAL") #! Record("CPIC:CP25:1013:CMD_OUT",3042,1932,0,1,"CPIC:CP25:1013:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP25 cryoplant number and area in cryoplant\n1013 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP25:1013:TEXT1",1739,2702,0,1,"CPIC:CP25:1013:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP25:1015:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP25:1015:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP25:1015:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP25:1015:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51015_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1015:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51015_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1015:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51015_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1015:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51015_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1015:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51015_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1015:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51015_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1015:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51015_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP25:1015:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51015_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1015:SP_RQST") { field(DESC, "C2PIC51015 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51015_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP25:1015:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51015_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP25:1015:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "C2PIC51015") } record(ao, "CPIC:CP25:1015:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51015.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP25:1015:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51015.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP25:1015:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP25:1015:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP25:1015:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) C2PV51015_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP25:1015:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015_OVH.Mode_Status") } record(bi, "CPIC:CP25:1015:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP25:1015:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1015:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP25:1015:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP25:1015:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP25:1015:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015_OVH.Mode_String") } record(bi, "CPIC:CP25:1015:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP25:1015:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP25:1015:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "C2PV51015") } record(ai, "CPIC:CP25:1015:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP25:1015:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP25:1015:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.MODE") } record(bo, "CPIC:CP25:1015:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51015_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP25:1015:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51015_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP25:1015:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51015_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP25:1015:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP25:1015:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) C2PV51015.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP25:1015:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1015:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP25:1015:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) C2PV51015o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP25:1015:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP25:1015:ORBV",2100,2312,0,1,"CPIC:CP25:1015:ORBV") #! Record("CPIC:CP25:1015:OVAL",2280,2312,0,1,"CPIC:CP25:1015:OVAL") #! Record("CPIC:CP25:1015:CVAL",2460,2312,0,1,"CPIC:CP25:1015:CVAL") #! Record("CPIC:CP25:1015:MAX",2122,1932,0,1,"CPIC:CP25:1015:MAX") #! Record("CPIC:CP25:1015:DMIN",2300,1932,0,1,"CPIC:CP25:1015:DMIN") #! Record("CPIC:CP25:1015:DMAX",2479,1932,0,1,"CPIC:CP25:1015:DMAX") #! Record("CPIC:CP25:1015:MDT",2120,2112,0,1,"CPIC:CP25:1015:MDT") #! Record("CPIC:CP25:1015:KP",2300,2106,0,1,"CPIC:CP25:1015:KP") #! Record("CPIC:CP25:1015:KI",2480,2106,0,1,"CPIC:CP25:1015:KI") #! Record("CPIC:CP25:1015:KD",2660,2106,0,1,"CPIC:CP25:1015:KD") #! Record("CPIC:CP25:1015:S",2840,2120,0,1,"CPIC:CP25:1015:S") #! Record("CPIC:CP25:1015:SP_RQST",1760,1932,0,1,"CPIC:CP25:1015:SP_RQST") #! Record("CPIC:CP25:1015:MIN",1945,1932,0,1,"CPIC:CP25:1015:MIN") #! Record("CPIC:CP25:1015:PIDTAG",1740,2462,0,1,"CPIC:CP25:1015:PIDTAG") #! Record("CPIC:CP25:1015:PEVAL",2660,1932,0,1,"CPIC:CP25:1015:PEVAL") #! Record("CPIC:CP25:1015:FSB",2840,1932,0,1,"CPIC:CP25:1015:FSB") #! Record("CPIC:CP25:1015:NOMATCH",3180,2499,0,1,"CPIC:CP25:1015:NOMATCH") #! Record("CPIC:CP25:1015:CHFAULT",3000,2506,0,1,"CPIC:CP25:1015:CHFAULT") #! Record("CPIC:CP25:1015:MANPOS_RQST",1940,2112,0,1,"CPIC:CP25:1015:MANPOS_RQST") #! Record("CPIC:CP25:1015:MODE_STATUS",1920,2314,0,1,"CPIC:CP25:1015:MODE_STATUS") #! Record("CPIC:CP25:1015:INTERLOCK",2460,2499,0,0,"CPIC:CP25:1015:INTERLOCK") #! Record("CPIC:CP25:1015:IVAL",2641,2312,0,1,"CPIC:CP25:1015:IVAL") #! Record("CPIC:CP25:1015:SVAL",2820,2312,0,1,"CPIC:CP25:1015:SVAL") #! Record("CPIC:CP25:1015:MMOD",2100,2506,0,1,"CPIC:CP25:1015:MMOD") #! Record("CPIC:CP25:1015:SMOD",2282,2506,0,1,"CPIC:CP25:1015:SMOD") #! Record("CPIC:CP25:1015:MODE_STRING",1740,2314,0,1,"CPIC:CP25:1015:MODE_STRING") #! Record("CPIC:CP25:1015:PMOD",1922,2479,0,1,"CPIC:CP25:1015:PMOD") #! Record("CPIC:CP25:1015:IMOD",2640,2499,0,1,"CPIC:CP25:1015:IMOD") #! Record("CPIC:CP25:1015:ACTUATOR",1740,2582,0,1,"CPIC:CP25:1015:ACTUATOR") #! Record("CPIC:CP25:1015:AVAL",3000,2312,0,1,"CPIC:CP25:1015:AVAL") #! Record("CPIC:CP25:1015:AMOD",2824,2506,0,1,"CPIC:CP25:1015:AMOD") #! Record("CPIC:CP25:1015:MODE",1760,2134,0,1,"CPIC:CP25:1015:MODE") #! Record("CPIC:CP25:1015:MANUAL",1951,2719,0,1,"CPIC:CP25:1015:MANUAL") #! Record("CPIC:CP25:1015:SEQUENCER",2140,2719,0,1,"CPIC:CP25:1015:SEQUENCER") #! Record("CPIC:CP25:1015:AUTO",2320,2719,0,1,"CPIC:CP25:1015:AUTO") #! Record("CPIC:CP25:1015:IL_LATCH",2680,2699,0,1,"CPIC:CP25:1015:IL_LATCH") #! Record("CPIC:CP25:1015:IL_RESET",2502,2719,0,1,"CPIC:CP25:1015:IL_RESET") #! Record("CPIC:CP25:1015:MVAL",3175,2312,0,1,"CPIC:CP25:1015:MVAL") #! Record("CPIC:CP25:1015:PVAL",3360,2312,0,1,"CPIC:CP25:1015:PVAL") #! Record("CPIC:CP25:1015:CMD_OUT",3042,1932,0,1,"CPIC:CP25:1015:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP25 cryoplant number and area in cryoplant\n1015 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP25:1015:TEXT1",1739,2702,0,1,"CPIC:CP25:1015:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP05:1051:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP05:1051:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP05:1051:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP05:1051:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51051_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1051:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51051_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1051:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51051_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1051:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51051_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1051:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51051_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1051:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51051_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1051:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51051_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP05:1051:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51051_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1051:SP_RQST") { field(DESC, "CPIC51051 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51051_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1051:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51051_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP05:1051:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "CPIC51051") } record(ao, "CPIC:CP05:1051:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51051.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP05:1051:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51051.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP05:1051:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP05:1051:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP05:1051:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51051_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP05:1051:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051_OVH.Mode_Status") } record(bi, "CPIC:CP05:1051:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP05:1051:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP05:1051:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP05:1051:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP05:1051:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP05:1051:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051_OVH.Mode_String") } record(bi, "CPIC:CP05:1051:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP05:1051:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP05:1051:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "CPV51051") } record(ai, "CPIC:CP05:1051:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP05:1051:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP05:1051:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.MODE") } record(bo, "CPIC:CP05:1051:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51051_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP05:1051:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51051_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP05:1051:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51051_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP05:1051:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP05:1051:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51051.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP05:1051:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP05:1051:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP05:1051:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51051o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP05:1051:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP05:1051:ORBV",2100,2312,0,1,"CPIC:CP05:1051:ORBV") #! Record("CPIC:CP05:1051:OVAL",2280,2312,0,1,"CPIC:CP05:1051:OVAL") #! Record("CPIC:CP05:1051:CVAL",2460,2312,0,1,"CPIC:CP05:1051:CVAL") #! Record("CPIC:CP05:1051:MAX",2122,1932,0,1,"CPIC:CP05:1051:MAX") #! Record("CPIC:CP05:1051:DMIN",2300,1932,0,1,"CPIC:CP05:1051:DMIN") #! Record("CPIC:CP05:1051:DMAX",2479,1932,0,1,"CPIC:CP05:1051:DMAX") #! Record("CPIC:CP05:1051:MDT",2120,2112,0,1,"CPIC:CP05:1051:MDT") #! Record("CPIC:CP05:1051:KP",2300,2106,0,1,"CPIC:CP05:1051:KP") #! Record("CPIC:CP05:1051:KI",2480,2106,0,1,"CPIC:CP05:1051:KI") #! Record("CPIC:CP05:1051:KD",2660,2106,0,1,"CPIC:CP05:1051:KD") #! Record("CPIC:CP05:1051:S",2840,2120,0,1,"CPIC:CP05:1051:S") #! Record("CPIC:CP05:1051:SP_RQST",1760,1932,0,1,"CPIC:CP05:1051:SP_RQST") #! Record("CPIC:CP05:1051:MIN",1945,1932,0,1,"CPIC:CP05:1051:MIN") #! Record("CPIC:CP05:1051:PIDTAG",1740,2462,0,1,"CPIC:CP05:1051:PIDTAG") #! Record("CPIC:CP05:1051:PEVAL",2660,1932,0,1,"CPIC:CP05:1051:PEVAL") #! Record("CPIC:CP05:1051:FSB",2840,1932,0,1,"CPIC:CP05:1051:FSB") #! Record("CPIC:CP05:1051:NOMATCH",3180,2499,0,1,"CPIC:CP05:1051:NOMATCH") #! Record("CPIC:CP05:1051:CHFAULT",3000,2506,0,1,"CPIC:CP05:1051:CHFAULT") #! Record("CPIC:CP05:1051:MANPOS_RQST",1940,2112,0,1,"CPIC:CP05:1051:MANPOS_RQST") #! Record("CPIC:CP05:1051:MODE_STATUS",1920,2314,0,1,"CPIC:CP05:1051:MODE_STATUS") #! Record("CPIC:CP05:1051:INTERLOCK",2460,2499,0,0,"CPIC:CP05:1051:INTERLOCK") #! Record("CPIC:CP05:1051:IVAL",2641,2312,0,1,"CPIC:CP05:1051:IVAL") #! Record("CPIC:CP05:1051:SVAL",2820,2312,0,1,"CPIC:CP05:1051:SVAL") #! Record("CPIC:CP05:1051:MMOD",2100,2506,0,1,"CPIC:CP05:1051:MMOD") #! Record("CPIC:CP05:1051:SMOD",2282,2506,0,1,"CPIC:CP05:1051:SMOD") #! Record("CPIC:CP05:1051:MODE_STRING",1740,2314,0,1,"CPIC:CP05:1051:MODE_STRING") #! Record("CPIC:CP05:1051:PMOD",1922,2479,0,1,"CPIC:CP05:1051:PMOD") #! Record("CPIC:CP05:1051:IMOD",2640,2499,0,1,"CPIC:CP05:1051:IMOD") #! Record("CPIC:CP05:1051:ACTUATOR",1740,2582,0,1,"CPIC:CP05:1051:ACTUATOR") #! Record("CPIC:CP05:1051:AVAL",3000,2312,0,1,"CPIC:CP05:1051:AVAL") #! Record("CPIC:CP05:1051:AMOD",2824,2506,0,1,"CPIC:CP05:1051:AMOD") #! Record("CPIC:CP05:1051:MODE",1760,2134,0,1,"CPIC:CP05:1051:MODE") #! Record("CPIC:CP05:1051:MANUAL",1951,2719,0,1,"CPIC:CP05:1051:MANUAL") #! Record("CPIC:CP05:1051:SEQUENCER",2140,2719,0,1,"CPIC:CP05:1051:SEQUENCER") #! Record("CPIC:CP05:1051:AUTO",2320,2719,0,1,"CPIC:CP05:1051:AUTO") #! Record("CPIC:CP05:1051:IL_LATCH",2680,2699,0,1,"CPIC:CP05:1051:IL_LATCH") #! Record("CPIC:CP05:1051:IL_RESET",2502,2719,0,1,"CPIC:CP05:1051:IL_RESET") #! Record("CPIC:CP05:1051:MVAL",3175,2312,0,1,"CPIC:CP05:1051:MVAL") #! Record("CPIC:CP05:1051:PVAL",3360,2312,0,1,"CPIC:CP05:1051:PVAL") #! Record("CPIC:CP05:1051:CMD_OUT",3042,1932,0,1,"CPIC:CP05:1051:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP05 cryoplant number and area in cryoplant\n1051 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP05:1051:TEXT1",1739,2702,0,1,"CPIC:CP05:1051:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP05:1053:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP05:1053:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP05:1053:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP05:1053:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51053_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1053:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51053_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1053:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51053_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1053:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51053_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1053:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51053_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1053:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51053_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1053:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51053_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP05:1053:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51053_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1053:SP_RQST") { field(DESC, "CPIC51053 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51053_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1053:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51053_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP05:1053:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "CPIC51053") } record(ao, "CPIC:CP05:1053:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51053.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP05:1053:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51053.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP05:1053:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP05:1053:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP05:1053:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51053_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP05:1053:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053_OVH.Mode_Status") } record(bi, "CPIC:CP05:1053:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP05:1053:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP05:1053:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP05:1053:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP05:1053:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP05:1053:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053_OVH.Mode_String") } record(bi, "CPIC:CP05:1053:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP05:1053:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP05:1053:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "CPV51053") } record(ai, "CPIC:CP05:1053:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP05:1053:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP05:1053:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.MODE") } record(bo, "CPIC:CP05:1053:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51053_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP05:1053:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51053_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP05:1053:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51053_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP05:1053:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP05:1053:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51053.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP05:1053:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP05:1053:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP05:1053:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51053o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP05:1053:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP05:1053:ORBV",2100,2312,0,1,"CPIC:CP05:1053:ORBV") #! Record("CPIC:CP05:1053:OVAL",2280,2312,0,1,"CPIC:CP05:1053:OVAL") #! Record("CPIC:CP05:1053:CVAL",2460,2312,0,1,"CPIC:CP05:1053:CVAL") #! Record("CPIC:CP05:1053:MAX",2122,1932,0,1,"CPIC:CP05:1053:MAX") #! Record("CPIC:CP05:1053:DMIN",2300,1932,0,1,"CPIC:CP05:1053:DMIN") #! Record("CPIC:CP05:1053:DMAX",2479,1932,0,1,"CPIC:CP05:1053:DMAX") #! Record("CPIC:CP05:1053:MDT",2120,2112,0,1,"CPIC:CP05:1053:MDT") #! Record("CPIC:CP05:1053:KP",2300,2106,0,1,"CPIC:CP05:1053:KP") #! Record("CPIC:CP05:1053:KI",2480,2106,0,1,"CPIC:CP05:1053:KI") #! Record("CPIC:CP05:1053:KD",2660,2106,0,1,"CPIC:CP05:1053:KD") #! Record("CPIC:CP05:1053:S",2840,2120,0,1,"CPIC:CP05:1053:S") #! Record("CPIC:CP05:1053:SP_RQST",1760,1932,0,1,"CPIC:CP05:1053:SP_RQST") #! Record("CPIC:CP05:1053:MIN",1945,1932,0,1,"CPIC:CP05:1053:MIN") #! Record("CPIC:CP05:1053:PIDTAG",1740,2462,0,1,"CPIC:CP05:1053:PIDTAG") #! Record("CPIC:CP05:1053:PEVAL",2660,1932,0,1,"CPIC:CP05:1053:PEVAL") #! Record("CPIC:CP05:1053:FSB",2840,1932,0,1,"CPIC:CP05:1053:FSB") #! Record("CPIC:CP05:1053:NOMATCH",3180,2499,0,1,"CPIC:CP05:1053:NOMATCH") #! Record("CPIC:CP05:1053:CHFAULT",3000,2506,0,1,"CPIC:CP05:1053:CHFAULT") #! Record("CPIC:CP05:1053:MANPOS_RQST",1940,2112,0,1,"CPIC:CP05:1053:MANPOS_RQST") #! Record("CPIC:CP05:1053:MODE_STATUS",1920,2314,0,1,"CPIC:CP05:1053:MODE_STATUS") #! Record("CPIC:CP05:1053:INTERLOCK",2460,2499,0,0,"CPIC:CP05:1053:INTERLOCK") #! Record("CPIC:CP05:1053:IVAL",2641,2312,0,1,"CPIC:CP05:1053:IVAL") #! Record("CPIC:CP05:1053:SVAL",2820,2312,0,1,"CPIC:CP05:1053:SVAL") #! Record("CPIC:CP05:1053:MMOD",2100,2506,0,1,"CPIC:CP05:1053:MMOD") #! Record("CPIC:CP05:1053:SMOD",2282,2506,0,1,"CPIC:CP05:1053:SMOD") #! Record("CPIC:CP05:1053:MODE_STRING",1740,2314,0,1,"CPIC:CP05:1053:MODE_STRING") #! Record("CPIC:CP05:1053:PMOD",1922,2479,0,1,"CPIC:CP05:1053:PMOD") #! Record("CPIC:CP05:1053:IMOD",2640,2499,0,1,"CPIC:CP05:1053:IMOD") #! Record("CPIC:CP05:1053:ACTUATOR",1740,2582,0,1,"CPIC:CP05:1053:ACTUATOR") #! Record("CPIC:CP05:1053:AVAL",3000,2312,0,1,"CPIC:CP05:1053:AVAL") #! Record("CPIC:CP05:1053:AMOD",2824,2506,0,1,"CPIC:CP05:1053:AMOD") #! Record("CPIC:CP05:1053:MODE",1760,2134,0,1,"CPIC:CP05:1053:MODE") #! Record("CPIC:CP05:1053:MANUAL",1951,2719,0,1,"CPIC:CP05:1053:MANUAL") #! Record("CPIC:CP05:1053:SEQUENCER",2140,2719,0,1,"CPIC:CP05:1053:SEQUENCER") #! Record("CPIC:CP05:1053:AUTO",2320,2719,0,1,"CPIC:CP05:1053:AUTO") #! Record("CPIC:CP05:1053:IL_LATCH",2680,2699,0,1,"CPIC:CP05:1053:IL_LATCH") #! Record("CPIC:CP05:1053:IL_RESET",2502,2719,0,1,"CPIC:CP05:1053:IL_RESET") #! Record("CPIC:CP05:1053:MVAL",3175,2312,0,1,"CPIC:CP05:1053:MVAL") #! Record("CPIC:CP05:1053:PVAL",3360,2312,0,1,"CPIC:CP05:1053:PVAL") #! Record("CPIC:CP05:1053:CMD_OUT",3042,1932,0,1,"CPIC:CP05:1053:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP05 cryoplant number and area in cryoplant\n1053 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP05:1053:TEXT1",1739,2702,0,1,"CPIC:CP05:1053:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP05:1054:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP05:1054:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP05:1054:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP05:1054:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51054_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1054:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51054_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1054:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51054_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1054:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51054_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1054:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51054_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1054:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51054_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1054:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51054_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP05:1054:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51054_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1054:SP_RQST") { field(DESC, "CPIC51054 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51054_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1054:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51054_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP05:1054:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "CPIC51054") } record(ao, "CPIC:CP05:1054:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51054.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP05:1054:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51054.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP05:1054:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP05:1054:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP05:1054:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51054_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP05:1054:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054_OVH.Mode_Status") } record(bi, "CPIC:CP05:1054:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP05:1054:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP05:1054:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP05:1054:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP05:1054:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP05:1054:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054_OVH.Mode_String") } record(bi, "CPIC:CP05:1054:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP05:1054:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP05:1054:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "CPV51054") } record(ai, "CPIC:CP05:1054:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP05:1054:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP05:1054:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.MODE") } record(bo, "CPIC:CP05:1054:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51054_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP05:1054:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51054_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP05:1054:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51054_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP05:1054:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP05:1054:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51054.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP05:1054:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP05:1054:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP05:1054:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51054o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP05:1054:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP05:1054:ORBV",2100,2312,0,1,"CPIC:CP05:1054:ORBV") #! Record("CPIC:CP05:1054:OVAL",2280,2312,0,1,"CPIC:CP05:1054:OVAL") #! Record("CPIC:CP05:1054:CVAL",2460,2312,0,1,"CPIC:CP05:1054:CVAL") #! Record("CPIC:CP05:1054:MAX",2122,1932,0,1,"CPIC:CP05:1054:MAX") #! Record("CPIC:CP05:1054:DMIN",2300,1932,0,1,"CPIC:CP05:1054:DMIN") #! Record("CPIC:CP05:1054:DMAX",2479,1932,0,1,"CPIC:CP05:1054:DMAX") #! Record("CPIC:CP05:1054:MDT",2120,2112,0,1,"CPIC:CP05:1054:MDT") #! Record("CPIC:CP05:1054:KP",2300,2106,0,1,"CPIC:CP05:1054:KP") #! Record("CPIC:CP05:1054:KI",2480,2106,0,1,"CPIC:CP05:1054:KI") #! Record("CPIC:CP05:1054:KD",2660,2106,0,1,"CPIC:CP05:1054:KD") #! Record("CPIC:CP05:1054:S",2840,2120,0,1,"CPIC:CP05:1054:S") #! Record("CPIC:CP05:1054:SP_RQST",1760,1932,0,1,"CPIC:CP05:1054:SP_RQST") #! Record("CPIC:CP05:1054:MIN",1945,1932,0,1,"CPIC:CP05:1054:MIN") #! Record("CPIC:CP05:1054:PIDTAG",1740,2462,0,1,"CPIC:CP05:1054:PIDTAG") #! Record("CPIC:CP05:1054:PEVAL",2660,1932,0,1,"CPIC:CP05:1054:PEVAL") #! Record("CPIC:CP05:1054:FSB",2840,1932,0,1,"CPIC:CP05:1054:FSB") #! Record("CPIC:CP05:1054:NOMATCH",3180,2499,0,1,"CPIC:CP05:1054:NOMATCH") #! Record("CPIC:CP05:1054:CHFAULT",3000,2506,0,1,"CPIC:CP05:1054:CHFAULT") #! Record("CPIC:CP05:1054:MANPOS_RQST",1940,2112,0,1,"CPIC:CP05:1054:MANPOS_RQST") #! Record("CPIC:CP05:1054:MODE_STATUS",1920,2314,0,1,"CPIC:CP05:1054:MODE_STATUS") #! Record("CPIC:CP05:1054:INTERLOCK",2460,2499,0,0,"CPIC:CP05:1054:INTERLOCK") #! Record("CPIC:CP05:1054:IVAL",2641,2312,0,1,"CPIC:CP05:1054:IVAL") #! Record("CPIC:CP05:1054:SVAL",2820,2312,0,1,"CPIC:CP05:1054:SVAL") #! Record("CPIC:CP05:1054:MMOD",2100,2506,0,1,"CPIC:CP05:1054:MMOD") #! Record("CPIC:CP05:1054:SMOD",2282,2506,0,1,"CPIC:CP05:1054:SMOD") #! Record("CPIC:CP05:1054:MODE_STRING",1740,2314,0,1,"CPIC:CP05:1054:MODE_STRING") #! Record("CPIC:CP05:1054:PMOD",1922,2479,0,1,"CPIC:CP05:1054:PMOD") #! Record("CPIC:CP05:1054:IMOD",2640,2499,0,1,"CPIC:CP05:1054:IMOD") #! Record("CPIC:CP05:1054:ACTUATOR",1740,2582,0,1,"CPIC:CP05:1054:ACTUATOR") #! Record("CPIC:CP05:1054:AVAL",3000,2312,0,1,"CPIC:CP05:1054:AVAL") #! Record("CPIC:CP05:1054:AMOD",2824,2506,0,1,"CPIC:CP05:1054:AMOD") #! Record("CPIC:CP05:1054:MODE",1760,2134,0,1,"CPIC:CP05:1054:MODE") #! Record("CPIC:CP05:1054:MANUAL",1951,2719,0,1,"CPIC:CP05:1054:MANUAL") #! Record("CPIC:CP05:1054:SEQUENCER",2140,2719,0,1,"CPIC:CP05:1054:SEQUENCER") #! Record("CPIC:CP05:1054:AUTO",2320,2719,0,1,"CPIC:CP05:1054:AUTO") #! Record("CPIC:CP05:1054:IL_LATCH",2680,2699,0,1,"CPIC:CP05:1054:IL_LATCH") #! Record("CPIC:CP05:1054:IL_RESET",2502,2719,0,1,"CPIC:CP05:1054:IL_RESET") #! Record("CPIC:CP05:1054:MVAL",3175,2312,0,1,"CPIC:CP05:1054:MVAL") #! Record("CPIC:CP05:1054:PVAL",3360,2312,0,1,"CPIC:CP05:1054:PVAL") #! Record("CPIC:CP05:1054:CMD_OUT",3042,1932,0,1,"CPIC:CP05:1054:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP05 cryoplant number and area in cryoplant\n1054 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP05:1054:TEXT1",1739,2702,0,1,"CPIC:CP05:1054:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP05:1055:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP05:1055:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP05:1055:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP05:1055:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51055_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1055:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51055_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1055:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51055_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1055:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51055_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1055:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51055_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1055:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51055_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1055:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51055_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP05:1055:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51055_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1055:SP_RQST") { field(DESC, "CPIC51055 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51055_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1055:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51055_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP05:1055:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "CPIC51055") } record(ao, "CPIC:CP05:1055:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51055.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP05:1055:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51055.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP05:1055:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP05:1055:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP05:1055:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51055_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP05:1055:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055_OVH.Mode_Status") } record(bi, "CPIC:CP05:1055:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP05:1055:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP05:1055:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP05:1055:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP05:1055:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP05:1055:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055_OVH.Mode_String") } record(bi, "CPIC:CP05:1055:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP05:1055:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP05:1055:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "CPV51055") } record(ai, "CPIC:CP05:1055:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP05:1055:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP05:1055:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.MODE") } record(bo, "CPIC:CP05:1055:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51055_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP05:1055:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51055_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP05:1055:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51055_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP05:1055:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP05:1055:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51055.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP05:1055:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP05:1055:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP05:1055:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51055o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP05:1055:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP05:1055:ORBV",2100,2312,0,1,"CPIC:CP05:1055:ORBV") #! Record("CPIC:CP05:1055:OVAL",2280,2312,0,1,"CPIC:CP05:1055:OVAL") #! Record("CPIC:CP05:1055:CVAL",2460,2312,0,1,"CPIC:CP05:1055:CVAL") #! Record("CPIC:CP05:1055:MAX",2122,1932,0,1,"CPIC:CP05:1055:MAX") #! Record("CPIC:CP05:1055:DMIN",2300,1932,0,1,"CPIC:CP05:1055:DMIN") #! Record("CPIC:CP05:1055:DMAX",2479,1932,0,1,"CPIC:CP05:1055:DMAX") #! Record("CPIC:CP05:1055:MDT",2120,2112,0,1,"CPIC:CP05:1055:MDT") #! Record("CPIC:CP05:1055:KP",2300,2106,0,1,"CPIC:CP05:1055:KP") #! Record("CPIC:CP05:1055:KI",2480,2106,0,1,"CPIC:CP05:1055:KI") #! Record("CPIC:CP05:1055:KD",2660,2106,0,1,"CPIC:CP05:1055:KD") #! Record("CPIC:CP05:1055:S",2840,2120,0,1,"CPIC:CP05:1055:S") #! Record("CPIC:CP05:1055:SP_RQST",1760,1932,0,1,"CPIC:CP05:1055:SP_RQST") #! Record("CPIC:CP05:1055:MIN",1945,1932,0,1,"CPIC:CP05:1055:MIN") #! Record("CPIC:CP05:1055:PIDTAG",1740,2462,0,1,"CPIC:CP05:1055:PIDTAG") #! Record("CPIC:CP05:1055:PEVAL",2660,1932,0,1,"CPIC:CP05:1055:PEVAL") #! Record("CPIC:CP05:1055:FSB",2840,1932,0,1,"CPIC:CP05:1055:FSB") #! Record("CPIC:CP05:1055:NOMATCH",3180,2499,0,1,"CPIC:CP05:1055:NOMATCH") #! Record("CPIC:CP05:1055:CHFAULT",3000,2506,0,1,"CPIC:CP05:1055:CHFAULT") #! Record("CPIC:CP05:1055:MANPOS_RQST",1940,2112,0,1,"CPIC:CP05:1055:MANPOS_RQST") #! Record("CPIC:CP05:1055:MODE_STATUS",1920,2314,0,1,"CPIC:CP05:1055:MODE_STATUS") #! Record("CPIC:CP05:1055:INTERLOCK",2460,2499,0,0,"CPIC:CP05:1055:INTERLOCK") #! Record("CPIC:CP05:1055:IVAL",2641,2312,0,1,"CPIC:CP05:1055:IVAL") #! Record("CPIC:CP05:1055:SVAL",2820,2312,0,1,"CPIC:CP05:1055:SVAL") #! Record("CPIC:CP05:1055:MMOD",2100,2506,0,1,"CPIC:CP05:1055:MMOD") #! Record("CPIC:CP05:1055:SMOD",2282,2506,0,1,"CPIC:CP05:1055:SMOD") #! Record("CPIC:CP05:1055:MODE_STRING",1740,2314,0,1,"CPIC:CP05:1055:MODE_STRING") #! Record("CPIC:CP05:1055:PMOD",1922,2479,0,1,"CPIC:CP05:1055:PMOD") #! Record("CPIC:CP05:1055:IMOD",2640,2499,0,1,"CPIC:CP05:1055:IMOD") #! Record("CPIC:CP05:1055:ACTUATOR",1740,2582,0,1,"CPIC:CP05:1055:ACTUATOR") #! Record("CPIC:CP05:1055:AVAL",3000,2312,0,1,"CPIC:CP05:1055:AVAL") #! Record("CPIC:CP05:1055:AMOD",2824,2506,0,1,"CPIC:CP05:1055:AMOD") #! Record("CPIC:CP05:1055:MODE",1760,2134,0,1,"CPIC:CP05:1055:MODE") #! Record("CPIC:CP05:1055:MANUAL",1951,2719,0,1,"CPIC:CP05:1055:MANUAL") #! Record("CPIC:CP05:1055:SEQUENCER",2140,2719,0,1,"CPIC:CP05:1055:SEQUENCER") #! Record("CPIC:CP05:1055:AUTO",2320,2719,0,1,"CPIC:CP05:1055:AUTO") #! Record("CPIC:CP05:1055:IL_LATCH",2680,2699,0,1,"CPIC:CP05:1055:IL_LATCH") #! Record("CPIC:CP05:1055:IL_RESET",2502,2719,0,1,"CPIC:CP05:1055:IL_RESET") #! Record("CPIC:CP05:1055:MVAL",3175,2312,0,1,"CPIC:CP05:1055:MVAL") #! Record("CPIC:CP05:1055:PVAL",3360,2312,0,1,"CPIC:CP05:1055:PVAL") #! Record("CPIC:CP05:1055:CMD_OUT",3042,1932,0,1,"CPIC:CP05:1055:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP05 cryoplant number and area in cryoplant\n1055 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP05:1055:TEXT1",1739,2702,0,1,"CPIC:CP05:1055:TEXT1") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBD("../../../dbd/cryoControl.dbd") #! DBDEND record(ai, "CPIC:CP05:1056:ORBV") { field(DESC, "PID ORBV") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.ORBV") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP05:1056:OVAL") { field(DESC, "PID OVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.OVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } # record(ai, "CPIC:CP05:1056:CVAL") { field(DESC, "PID CVAL") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.CVAL") field(PREC, "2") field(EGU, "bara") field(ADEL, ".01") } record(ao, "CPIC:CP05:1056:MAX") { field(DESC, "PID SP Max") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51056_OVH.MAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1056:DMIN") { field(DESC, "PID SP DMIN") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51056_OVH.DMIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1056:DMAX") { field(DESC, "PID SP DMAX") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51056_OVH.DMAX_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1056:MDT") { field(DESC, "PID ST MDT") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51056_OVH.ST_X") field(PREC, "2") field(EGU, "Sec") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1056:KP") { field(DESC, "PID Proportional Gain Kp") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51056_OVH.GAINP_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1056:KI") { field(DESC, "PID Integral Gain Ki") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51056_OVH.GAINI_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1056:KD") { field(DESC, "PID Derivative Gain Kd") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51056_OVH.GAIND_X") field(PREC, "2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringout, "CPIC:CP05:1056:S") { field(DESC, "rqstd process variable name") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51056_OVH.PV_String_X S 2") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1056:SP_RQST") { field(DESC, "CPIC51056 PID SP request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51056_OVH.SP_Rqst") field(PREC, "2") field(EGU, "bara") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ao, "CPIC:CP05:1056:MIN") { field(DESC, "PID SP Min") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51056_OVH.MIN_X") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(stringin, "CPIC:CP05:1056:PIDTAG") { field(DESC, "P&ID tag for the PID loop") field(PINI, "YES") field(VAL, "CPIC51056") } record(ao, "CPIC:CP05:1056:PEVAL") { field(DESC, "PID Fail Safe V Pos.") field(ASG, "CRYO") field(PINI, "NO") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51056.PEVAL") field(PREC, "2") field(EGU, "%") field(IVOA, "Don't drive outputs") } record(bo, "CPIC:CP05:1056:FSB") { field(DESC, "PID Fail Safe bit") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51056.FSB B 0") field(ZNAM, "fail last") field(ONAM, "pval") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(bi, "CPIC:CP05:1056:NOMATCH") { field(DESC, "PID inp var no match") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056_OVH.NoMatch") field(ZNAM, "match") field(ONAM, "no match") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP05:1056:CHFAULT") { field(DESC, "PID inp ch fault") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056_OVH.CHFault") field(ZNAM, "ok") field(ONAM, "fault") } record(ao, "CPIC:CP05:1056:MANPOS_RQST") { field(DESC, "PID Manual Posn request") field(DTYP, "EtherIP") field(OUT, "@$(PLC_NAME) CPV51056_OVH.ManPos_Rqst") field(PREC, "2") field(EGU, "%") field(ASG, "CRYO") field(PINI, "NO") field(IVOA, "Don't drive outputs") } record(ai, "CPIC:CP05:1056:MODE_STATUS") { field(DESC, "PID Mode Status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056_OVH.Mode_Status") } record(bi, "CPIC:CP05:1056:INTERLOCK") { field(DESC, "PID Interlock Condition") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.Interlock_Condition") field(ZNAM, "OK") field(ONAM, "Interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(ai, "CPIC:CP05:1056:IVAL") { field(DESC, "PID Interlock output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.IVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP05:1056:SVAL") { field(DESC, "PID Sequencer output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.SVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP05:1056:MMOD") { field(DESC, "PID Manual Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.mmod") field(ZNAM, "not manual") field(ONAM, "manual") } record(bi, "CPIC:CP05:1056:SMOD") { field(DESC, "PID Sequencer Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.smod") field(ZNAM, "not sequencer") field(ONAM, "sequencer") } record(stringin, "CPIC:CP05:1056:MODE_STRING") { field(DESC, "PID Mode String") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056_OVH.Mode_String") } record(bi, "CPIC:CP05:1056:PMOD") { field(DESC, "PID Protector Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.pmod") field(ZNAM, "not protector") field(ONAM, "protector") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "CPIC:CP05:1056:IMOD") { field(DESC, "PID Interlock Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.imod") field(ZNAM, "no interlock") field(ONAM, "interlocked") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(stringin, "CPIC:CP05:1056:ACTUATOR") { field(DESC, "actuator name for the pid loop") field(PINI, "YES") field(VAL, "CPV51056") } record(ai, "CPIC:CP05:1056:AVAL") { field(DESC, "PID Auto mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.AVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(bi, "CPIC:CP05:1056:AMOD") { field(DESC, "PID Auto Mode status") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.amod") field(ZNAM, "not auto") field(ONAM, "auto") } record(ai, "CPIC:CP05:1056:MODE") { field(DESC, "PIDloop mode (man,auto,seq,prot,intl)") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.MODE") } record(bo, "CPIC:CP05:1056:MANUAL") { field(DESC, "Manual Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51056_OVH.Manual B 0") field(ZNAM, "not manual") field(ONAM, "Manual") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP05:1056:SEQUENCER") { field(DESC, "SequencerMode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51056_OVH.Sequencer B 0") field(ZNAM, "not sequencer") field(ONAM, "Sequencer") field(ASG, "CRYO") field(HIGH, "1") } record(bo, "CPIC:CP05:1056:AUTO") { field(DESC, "Auto Mode request ") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51056_OVH.Auto B 0") field(ZNAM, "not Auto") field(ONAM, "Auto") field(ASG, "CRYO") field(HIGH, "1") } record(bi, "CPIC:CP05:1056:IL_LATCH") { field(DESC, "interlock latched indicator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.Interlock_Condition_L") field(ZNAM, "ok") field(ONAM, "latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "CPIC:CP05:1056:IL_RESET") { field(DESC, "Interlock Latch Reset") field(PINI, "NO") field(DTYP, "EtherIP") field(OMSL, "supervisory") field(OUT, "@$(PLC_NAME) CPV51056.Interlock_Condition_Reset B 0") field(ZNAM, "not reset") field(ONAM, "RESET") field(ASG, "CRYO") field(HIGH, "1") } record(ai, "CPIC:CP05:1056:MVAL") { field(DESC, "PID manual mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.MVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP05:1056:PVAL") { field(DESC, "PID protector mode output value") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056.PVAL") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(ai, "CPIC:CP05:1056:CMD_OUT") { field(DESC, "PID output cmd the actuator") field(SCAN, "1 second") field(PINI, "YES") field(DTYP, "EtherIP") field(INP, "@$(PLC_NAME) CPV51056o") field(PREC, "2") field(EGU, "%") field(ADEL, ".01") } record(stringin, "CPIC:CP05:1056:TEXT1") { field(DESC, "Actuator Namestring") field(PINI, "YES") field(DTYP, "Soft Channel") info(autosaveFields, "VAL") } #! Further lines contain data used by VisualDCT #! View(1648,1899,1.0) #! Record("CPIC:CP05:1056:ORBV",2100,2312,0,1,"CPIC:CP05:1056:ORBV") #! Record("CPIC:CP05:1056:OVAL",2280,2312,0,1,"CPIC:CP05:1056:OVAL") #! Record("CPIC:CP05:1056:CVAL",2460,2312,0,1,"CPIC:CP05:1056:CVAL") #! Record("CPIC:CP05:1056:MAX",2122,1932,0,1,"CPIC:CP05:1056:MAX") #! Record("CPIC:CP05:1056:DMIN",2300,1932,0,1,"CPIC:CP05:1056:DMIN") #! Record("CPIC:CP05:1056:DMAX",2479,1932,0,1,"CPIC:CP05:1056:DMAX") #! Record("CPIC:CP05:1056:MDT",2120,2112,0,1,"CPIC:CP05:1056:MDT") #! Record("CPIC:CP05:1056:KP",2300,2106,0,1,"CPIC:CP05:1056:KP") #! Record("CPIC:CP05:1056:KI",2480,2106,0,1,"CPIC:CP05:1056:KI") #! Record("CPIC:CP05:1056:KD",2660,2106,0,1,"CPIC:CP05:1056:KD") #! Record("CPIC:CP05:1056:S",2840,2120,0,1,"CPIC:CP05:1056:S") #! Record("CPIC:CP05:1056:SP_RQST",1760,1932,0,1,"CPIC:CP05:1056:SP_RQST") #! Record("CPIC:CP05:1056:MIN",1945,1932,0,1,"CPIC:CP05:1056:MIN") #! Record("CPIC:CP05:1056:PIDTAG",1740,2462,0,1,"CPIC:CP05:1056:PIDTAG") #! Record("CPIC:CP05:1056:PEVAL",2660,1932,0,1,"CPIC:CP05:1056:PEVAL") #! Record("CPIC:CP05:1056:FSB",2840,1932,0,1,"CPIC:CP05:1056:FSB") #! Record("CPIC:CP05:1056:NOMATCH",3180,2499,0,1,"CPIC:CP05:1056:NOMATCH") #! Record("CPIC:CP05:1056:CHFAULT",3000,2506,0,1,"CPIC:CP05:1056:CHFAULT") #! Record("CPIC:CP05:1056:MANPOS_RQST",1940,2112,0,1,"CPIC:CP05:1056:MANPOS_RQST") #! Record("CPIC:CP05:1056:MODE_STATUS",1920,2314,0,1,"CPIC:CP05:1056:MODE_STATUS") #! Record("CPIC:CP05:1056:INTERLOCK",2460,2499,0,0,"CPIC:CP05:1056:INTERLOCK") #! Record("CPIC:CP05:1056:IVAL",2641,2312,0,1,"CPIC:CP05:1056:IVAL") #! Record("CPIC:CP05:1056:SVAL",2820,2312,0,1,"CPIC:CP05:1056:SVAL") #! Record("CPIC:CP05:1056:MMOD",2100,2506,0,1,"CPIC:CP05:1056:MMOD") #! Record("CPIC:CP05:1056:SMOD",2282,2506,0,1,"CPIC:CP05:1056:SMOD") #! Record("CPIC:CP05:1056:MODE_STRING",1740,2314,0,1,"CPIC:CP05:1056:MODE_STRING") #! Record("CPIC:CP05:1056:PMOD",1922,2479,0,1,"CPIC:CP05:1056:PMOD") #! Record("CPIC:CP05:1056:IMOD",2640,2499,0,1,"CPIC:CP05:1056:IMOD") #! Record("CPIC:CP05:1056:ACTUATOR",1740,2582,0,1,"CPIC:CP05:1056:ACTUATOR") #! Record("CPIC:CP05:1056:AVAL",3000,2312,0,1,"CPIC:CP05:1056:AVAL") #! Record("CPIC:CP05:1056:AMOD",2824,2506,0,1,"CPIC:CP05:1056:AMOD") #! Record("CPIC:CP05:1056:MODE",1760,2134,0,1,"CPIC:CP05:1056:MODE") #! Record("CPIC:CP05:1056:MANUAL",1951,2719,0,1,"CPIC:CP05:1056:MANUAL") #! Record("CPIC:CP05:1056:SEQUENCER",2140,2719,0,1,"CPIC:CP05:1056:SEQUENCER") #! Record("CPIC:CP05:1056:AUTO",2320,2719,0,1,"CPIC:CP05:1056:AUTO") #! Record("CPIC:CP05:1056:IL_LATCH",2680,2699,0,1,"CPIC:CP05:1056:IL_LATCH") #! Record("CPIC:CP05:1056:IL_RESET",2502,2719,0,1,"CPIC:CP05:1056:IL_RESET") #! Record("CPIC:CP05:1056:MVAL",3175,2312,0,1,"CPIC:CP05:1056:MVAL") #! Record("CPIC:CP05:1056:PVAL",3360,2312,0,1,"CPIC:CP05:1056:PVAL") #! Record("CPIC:CP05:1056:CMD_OUT",3042,1932,0,1,"CPIC:CP05:1056:CMD_OUT") #! TextBox(TB0,2240,1780,2700,1880,0,"Dialog",12,1,16777215,"Records for PID control loops\nCPIC is the primary portion of device name\nCP05 cryoplant number and area in cryoplant\n1056 location of device as per P&ID diagram\n% EGU of the I/O value",null) #! Record("CPIC:CP05:1056:TEXT1",1739,2702,0,1,"CPIC:CP05:1056:TEXT1")